{"id":2718,"date":"2026-06-09T17:09:38","date_gmt":"2026-06-09T09:09:38","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2718"},"modified":"2026-10-23T11:13:18","modified_gmt":"2026-10-23T03:13:18","slug":"%e4%bb%bb%e5%a5%b3%e5%a3%ab%c2%b7%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e7%83%ad%e6%b0%b4-%e6%96%b9%e6%a1%88%e5%89%8d%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2718","title":{"rendered":"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u4efb\u5973\u58eb<br><strong>\u6237\u578b\u6982\u51b5<\/strong>\uff1a125\u33a1\u4e09\u5ba4\uff0c\u5e38\u4f4f3\u4eba<br><strong>\u6838\u5fc3\u9700\u6c42<\/strong>\uff1a\u4e2d\u592e\u7a7a\u8c03\uff08\u5236\u51b7\/\u5236\u70ed\uff09+ \u5730\u6696 + \u751f\u6d3b\u70ed\u6c34\uff0c\u9884\u7b975\u4e07\u5de6\u53f3\uff0c\u6548\u679c\u597d\u3001\u4e0d\u8d39\u6c14<br><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u4f59\u7231\u82f1<br><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e746\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e00\u6b65\uff1a\u60a8\u7684\u9700\u6c42\u56de\u987e<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1.1 \u60a8\u8bf4\u7684 vs \u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u8bf4\u7684<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u51b3\u65b9\u6848<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u670b\u53cb\u5bb6\u5730\u6696\u5236\u70ed\u6548\u679c\u4e0d\u597d\u201d<\/td><td>\u6015\u81ea\u5df1\u5bb6\u4e5f\u88c5\u4e86\u4e0d\u70ed<\/td><td>\u6539\u752832+20\u5927\u6d41\u91cf\u7ba1\u8def\uff0c\u6d41\u91cf\u63d0\u5347100%\uff0c\u8fdc\u7aef\u4e5f\u70ed<\/td><\/tr><tr><td>\u201c\u62c5\u5fc3\u71c3\u6c14\u8d39\u592a\u9ad8\u201d<\/td><td>\u6015\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77<\/td><td>\u8282\u80fd\u578b\u7cfb\u7edf\u8bbe\u8ba1+\u51b7\u51dd\u7089\/\u5355\u91c7\u6696\u7089+\u8054\u52a8\u63a7\u5236<\/td><\/tr><tr><td>\u201c\u9884\u7b97\u6709\u9650\uff0c\u60f3\u6027\u4ef7\u6bd4\u9ad8\u201d<\/td><td>\u5e0c\u671b\u94b1\u82b1\u5728\u5200\u5203\u4e0a<\/td><td>\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\uff08\u66fc\u745e\u5fb7+\u745e\u7f8e\uff09\u6bd4\u4e00\u4f53\u673a\u66f4\u7075\u6d3b<\/td><\/tr><tr><td>\u201c\u62c5\u5fc3\u6d17\u6fa1\u6c34\u5ffd\u51b7\u5ffd\u70ed\u201d<\/td><td>\u6015\u51ac\u5929\u6d17\u6fa1\u6c34\u4e0d\u7a33<\/td><td>\u72ec\u7acb\u70ed\u6c34\u566816L\uff0c\u91c7\u6696\u70ed\u6c34\u4e0d\u62a2\u529f\u7387<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">1.2 \u60a8\u5bb6\u6237\u578b\u4e0e\u4f7f\u7528\u4e60\u60ef<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u5efa\u7b51\u9762\u79ef<\/td><td>125\u33a1\u4e09\u5ba4<\/td><\/tr><tr><td>\u5e38\u4f4f\u4eba\u53e3<\/td><td>3\u4eba<\/td><\/tr><tr><td>\u5730\u6696\u9762\u79ef<\/td><td>\u7ea685\u33a1<\/td><\/tr><tr><td>\u4f7f\u7528\u4e60\u60ef<\/td><td>\u5730\u6696\u5168\u5929\u5f00\u542f\uff0c\u5ba2\u9910\u5385+\u5367\u5ba4\u5206\u533a\u57df\u4f7f\u7528<\/td><\/tr><tr><td>\u70ed\u6c34\u9700\u6c42<\/td><td>1-2\u4e2a\u536b\u751f\u95f4\uff0c\u6b63\u5e38\u6dcb\u6d74<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e8c\u6b65\uff1a\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\uff08\u8212\u4eab125\u4e00\u62d6\u56db\uff09<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">2.1 \u914d\u7f6e\u4e0e\u8d85\u914d\u7387\u6838\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5916\u673a<\/strong><\/td><td>\u8212\u4eab125\u5355\u98ce\u6247 RAS-125HRNAQ\uff08\u5236\u51b7\u91cf12.5kW\uff09<\/td><\/tr><tr><td><strong>\u5ba2\u9910\u5385<\/strong><\/td><td>71\u578b\u5185\u673a\uff087.1kW\uff09<\/td><\/tr><tr><td><strong>\u6b21\u5367\/\u4e66\u623f<\/strong><\/td><td>28\u578b\u5185\u673a\uff082.8kW\uff09<\/td><\/tr><tr><td><strong>\u4e3b\u5367<\/strong><\/td><td>40\u578b\u5185\u673a\uff084.0kW\uff09<\/td><\/tr><tr><td><strong>\u5907\u7528\/\u4e66\u623f<\/strong><\/td><td>22\u578b\u5185\u673a\uff082.2kW\uff09<\/td><\/tr><tr><td><strong>\u5185\u673a\u603b\u51b7\u91cf<\/strong><\/td><td>7.1+2.8+4.0+2.2=<strong>16.1kW<\/strong><\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>16.1\u00f712.5\u2248<strong>128.8%<\/strong>\uff08\u5141\u8bb8\u8303\u56f450%-130%\u2705\uff09<\/td><\/tr><tr><td><strong>\u9002\u5408\u573a\u666f<\/strong><\/td><td>125\u33a1\u4e09\u5ba4\uff0c\u5e38\u4f4f3\u4eba\uff0c\u65e5\u5e38\u5f001-2\u53f0\u5185\u673a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u2705&nbsp;<strong>\u8d85\u914d\u7387128.8%<\/strong>\uff0c\u63a5\u8fd1\u4f46\u672a\u8d85\u8fc7130%\u4e0a\u9650\uff0c\u5904\u4e8e\u5408\u7406\u533a\u95f4\u4e0a\u9650\u3002\u5168\u5f00\u65f6\u6548\u679c\u6709\u4fdd\u969c\uff0c\u65e5\u5e38\u5f001-2\u53f0\u65f6\u5916\u673a\u5339\u914d\u826f\u597d\uff0c\u4e0d\u4f1a\u9891\u7e41\u542f\u505c\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">2.2 \u8212\u4eab125\u5916\u673a\u6838\u5fc3\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673a\u578b\u53f7<\/td><td>RAS-125HRNAQ<\/td><td>\u2014<\/td><\/tr><tr><td>\u5236\u51b7\u91cf<\/td><td>12.5 kW<\/td><td>\u2014<\/td><\/tr><tr><td>\u5236\u70ed\u91cf<\/td><td>14.0 kW<\/td><td>\u2014<\/td><\/tr><tr><td>APF\u80fd\u6548<\/td><td><strong>5.90<\/strong><\/td><td>\u8fdc\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c\u975e\u5e38\u7701\u7535<\/td><\/tr><tr><td>\u538b\u7f29\u673a<\/td><td><strong>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/strong><\/td><td>\u4f4e\u9891\u7a33\u5b9a\u8282\u80fd\uff0c\u9002\u5408\u60a8\u5bb6\u5e38\u5f001-2\u53f0\u7684\u573a\u666f<\/td><\/tr><tr><td>\u5916\u673a\u5c3a\u5bf8<\/td><td>770\u00d7980\u00d7360mm<\/td><td>\u4f53\u79ef\u5c0f\u5de7\uff0c\u5b89\u88c5\u7075\u6d3b<\/td><\/tr><tr><td>\u7535\u6e90<\/td><td>220V<\/td><td>\u666e\u901a\u5bb6\u5ead\u7528\u7535\uff0c\u4e0d\u7528\u6539380V<\/td><\/tr><tr><td>\u6838\u5fc3\u529f\u80fd<\/td><td>\u53cd\u8f6c\u9664\u5c18\u3001\u516d\u8109\u6ce2\u52a0\u70ed\u3001\u81ea\u6e05\u6d01<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u60f3\u4e86\u89e3\u66f4\u591a\u8212\u4eab\u7cfb\u5217\u8be6\u60c5\uff1f<\/strong>&nbsp;<a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" rel=\"noreferrer noopener\">\u70b9\u51fb\u67e5\u770b\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u5b8c\u6574\u4ecb\u7ecd<\/a><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">2.3 \u8212\u4eab\u5185\u673a\u6838\u5fc3\u529f\u80fd\uff08\u5168\u7cfb\u6807\u914d\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ef7\u503c<\/th><\/tr><\/thead><tbody><tr><td><strong>\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc<\/strong><\/td><td>\u7a7a\u8c03\u81ea\u5df1\u6d17\uff0c\u51fa\u98ce\u65e0\u5f02\u5473\uff0c\u4e0d\u7528\u8bf7\u4eba<\/td><\/tr><tr><td><strong>\u8d85\u9759\u97f3\uff0817dB\uff09<\/strong><\/td><td>\u6bd4\u7ffb\u4e66\u58f0\u8fd8\u8f7b\uff0c\u7761\u7720\u4e0d\u5435<\/td><\/tr><tr><td><strong>PE\u51c0\u5316\u6a21\u5757<\/strong><\/td><td>\u9664PM2.5\/\u7532\u919b\uff0c\u51fa\u98ce\u6d01\u51c0<\/td><\/tr><tr><td><strong>\u6807\u914d\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173<\/strong><\/td><td>\u4e0d\u6ce1\u9876\uff0c\u540a\u9876\u66f4\u81ea\u7531<\/td><\/tr><tr><td><strong>\u8d85\u8584\u673a\u8eab\uff08192mm\uff09<\/strong><\/td><td>\u5b8c\u7f8e\u9690\u85cf\u4e8e\u540a\u9876<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2.4 \u8212\u4eab125\u65b9\u6848\u4e00\u53e5\u8bdd\u603b\u7ed3<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u8fd9\u5957\u7a7a\u8c03\u4e00\u62d6\u56db\uff0c\u8d85\u914d\u7387128.8%\u8bbe\u8ba1\u5408\u7406\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u5728\u60a8\u5bb6\u5e38\u5f001-2\u53f0\u7684\u573a\u666f\u4e0b\u975e\u5e38\u7701\u7535\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\u4e0d\u5435\uff0c\u81ea\u6e05\u6d01\u529f\u80fd\u4e0d\u7528\u8bf7\u4eba\u6d17\u3002\u4e3b\u5367\u914d40\u578b\u5185\u673a\uff0c\u5236\u51b7\u5236\u70ed\u66f4\u5feb\u3002\u201d<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e09\u6b65\uff1a\u5730\u6696+\u70ed\u6c34\u65b9\u6848\u5bf9\u6bd4<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">3.1 \u4e24\u79cd\u65b9\u6848\u6838\u5fc3\u5bf9\u6bd4<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848A\uff1a\u83f2\u65af\u66fc\u51b7\u51dd\u4e00\u4f53\u673a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848B\uff1a\u91c7\u6696\u70ed\u6c34\u5206\u79bb\uff08\u2705\u63a8\u8350\uff09<\/th><\/tr><\/thead><tbody><tr><td><strong>\u91c7\u6696\u8bbe\u5907<\/strong><\/td><td>\u83f2\u65af\u66fc24kW\u51b7\u51dd\u7089\uff08\u4e24\u7528\uff09<\/td><td>\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089<\/td><\/tr><tr><td><strong>\u70ed\u6c34\u8bbe\u5907<\/strong><\/td><td>\u9505\u7089\u81ea\u5e26\uff08\u4e24\u7528\uff09<\/td><td><strong>\u745e\u7f8e16L\u72ec\u7acb\u6052\u6e29\u70ed\u6c34\u5668<\/strong><\/td><\/tr><tr><td><strong>\u91c7\u6696\u529f\u7387<\/strong><\/td><td>24kW<\/td><td>18kW\uff08\u5339\u914d85\u33a1\u8db3\u591f\uff09<\/td><\/tr><tr><td><strong>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/strong><\/td><td>\u7ea63.1kW<\/td><td>\u7ea65.6kW<\/td><\/tr><tr><td><strong>\u91c7\u6696\u4e0e\u70ed\u6c34\u5173\u7cfb<\/strong><\/td><td>\u26a0\ufe0f&nbsp;<strong>\u5171\u7528\u4e00\u5957\u7cfb\u7edf\uff0c\u4f1a\u62a2\u529f\u7387<\/strong><\/td><td>\u2705&nbsp;<strong>\u5b8c\u5168\u5206\u79bb\uff0c\u4e92\u4e0d\u5e72\u6270<\/strong><\/td><\/tr><tr><td><strong>\u51ac\u5b63\u6d17\u6fa1\u7a33\u5b9a\u6027<\/strong><\/td><td>\u5f00\u5730\u6696\u65f6\u70ed\u6c34\u6d41\u91cf\u4e0b\u964d<\/td><td><strong>\u70ed\u6c34\u5668\u72ec\u7acb\u5de5\u4f5c\uff0c\u6d41\u91cf\u7a33\u5b9a<\/strong><\/td><\/tr><tr><td><strong>\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb<\/strong><\/td><td>\u274c \u4e24\u7528\u7089\u590f\u5b63\u6700\u5c0f\u529f\u7387\u504f\u5927<\/td><td>\u2705 \u70ed\u6c34\u5668\u5206\u6bb5\u71c3\u70e7\uff0c\u6c34\u6e29\u7a33\u5b9a<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u590d\u6742\u5ea6<\/strong><\/td><td>\u7b80\u5355\uff08\u4e00\u53f0\u8bbe\u5907\uff09<\/td><td>\u7a0d\u590d\u6742\uff08\u4e24\u53f0\u8bbe\u5907\uff0c\u9700\u71c3\u6c14\u4e09\u901a\uff09<\/td><\/tr><tr><td><strong>\u521d\u6295\u8d44<\/strong><\/td><td>\u7ea615,000-18,000\u5143<\/td><td><strong>\u7ea64,000+3,000=7,000\u5143\uff08\u77018,000-11,000\u5143\uff09<\/strong><\/td><\/tr><tr><td><strong>\u8bbe\u5907\u5bff\u547d<\/strong><\/td><td>10-15\u5e74\uff08\u91c7\u6696+\u70ed\u6c34\u8054\u52a8\u4f7f\u7528\uff09<\/td><td><strong>\u91c7\u6696\u708915\u5e74+\u70ed\u6c34\u56688-10\u5e74\uff08\u4e92\u4e0d\u5f71\u54cd\uff09<\/strong><\/td><\/tr><tr><td><strong>\u9002\u5408\u573a\u666f<\/strong><\/td><td>\u9884\u7b97\u5145\u8db3\u3001\u8ffd\u6c42\u7b80\u6d01<\/td><td><strong>\u9884\u7b97\u4f18\u5148\u3001\u8ffd\u6c42\u70ed\u6c34\u7a33\u5b9a\u3001\u6027\u4ef7\u6bd4<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.2 \u4e3a\u4ec0\u4e48\u63a8\u8350\u201c\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u201d\uff1f<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u52bf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td><strong>\u70ed\u6c34\u7a33\u5b9a<\/strong><\/td><td>\u70ed\u6c34\u5668\u72ec\u7acb\u5de5\u4f5c\uff0c\u91c7\u6696\u5f00\u4e0d\u5f00\u90fd\u4e0d\u5f71\u54cd\u6d17\u6fa1\u6c34<\/td><\/tr><tr><td><strong>\u590f\u5b63\u4e0d\u70eb<\/strong><\/td><td>\u745e\u7f8e16L\u70ed\u6c34\u5668\u5e26\u5206\u6bb5\u71c3\u70e7\uff0c\u590f\u5929\u5c0f\u6c34\u91cf\u4e0d\u4f1a\u8fc7\u70eb<\/td><\/tr><tr><td><strong>\u91c7\u6696\u66f4\u8282\u80fd<\/strong><\/td><td>18kW\u5355\u91c7\u6696\u7089\u5339\u914d85\u33a1\u5730\u6696\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u4e0d\u9891\u7e41\u542f\u505c<\/td><\/tr><tr><td><strong>\u7ef4\u4fee\u4e0d\u5f71\u54cd<\/strong><\/td><td>\u91c7\u6696\u7089\u574f\u4e86\u4e0d\u5f71\u54cd\u70ed\u6c34\uff0c\u70ed\u6c34\u5668\u574f\u4e86\u4e0d\u5f71\u54cd\u91c7\u6696<\/td><\/tr><tr><td><strong>\u521d\u6295\u8d44\u77018,000-11,000\u5143<\/strong><\/td><td>\u4e00\u4f53\u673a\u591a\u82b1\u7684\u94b1\uff0c\u591f\u4e70\u4e00\u53f0\u72ec\u7acb\u70ed\u6c34\u5668+\u51e0\u5e74\u71c3\u6c14\u8d39<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.3 \u4e24\u65b9\u6848\u8bbe\u5907\u660e\u7ec6<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u65b9\u6848A\uff1a\u83f2\u65af\u66fc24kW\u51b7\u51dd\u4e00\u4f53\u673a<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9884\u4f30\u4ef7\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><tbody><tr><td>\u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/td><td>Vitodens 100-C 24kW<\/td><td>\u7ea615,000-18,000\u5143<\/td><td>\u5730\u6696+\u751f\u6d3b\u70ed\u6c34\u5171\u7528<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u60f3\u4e86\u89e3\u66f4\u591a\u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5\uff1f<\/strong>&nbsp;<a href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\" rel=\"noreferrer noopener\">\u70b9\u51fb\u67e5\u770b\u83f2\u65af\u66fc\u91c7\u6696\u7cfb\u7edf\u5b8c\u6574\u4ecb\u7ecd<\/a><\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\">\u65b9\u6848B\uff1a\u66fc\u745e\u5fb7\u5355\u91c7\u6696 + \u745e\u7f8e\u70ed\u6c34\u5668\uff08\u2705\u63a8\u8350\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9884\u4f30\u4ef7\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><tbody><tr><td>\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089<\/td><td><a href=\"https:\/\/n1pb18-hi.pro\/\" target=\"_blank\" rel=\"noreferrer noopener\">N1PB18-HI.Pro<\/a>&nbsp;18kW<\/td><td>\u7ea64,000-5,000\u5143<\/td><td><strong>\u53ea\u8d1f\u8d23\u5730\u6696<\/strong><\/td><\/tr><tr><td>\u745e\u7f8e\u6052\u6e29\u70ed\u6c34\u5668<\/td><td>16L\uff08\u5206\u6bb5\u71c3\u70e7\uff09<\/td><td>\u7ea62,500-3,000\u5143<\/td><td><strong>\u53ea\u8d1f\u8d23\u751f\u6d3b\u70ed\u6c34<\/strong><\/td><\/tr><tr><td>\u71c3\u6c14\u4e09\u901a\u53ca\u7ba1\u8def<\/td><td>\u2014<\/td><td>\u7ea6500-800\u5143<\/td><td>\u8fde\u63a5\u4e24\u53f0\u8bbe\u5907<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u60f3\u4e86\u89e3\u66f4\u591a\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5\uff1f<\/strong>&nbsp;<a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" rel=\"noreferrer noopener\">\u70b9\u51fb\u67e5\u770b\u66fc\u745e\u5fb7\u91c7\u6696\u7cfb\u7edf\u5b8c\u6574\u4ecb\u7ecd<\/a><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">3.4 \u5730\u6696\u7ba1\u8def\u5bf9\u6bd4\uff1a25+16 vs 32+20\uff08\u8282\u80fd\u578b\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e02\u573a\u901a\u914d\u578b\uff0825+16\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8282\u80fd\u578b\uff0832+20\uff09\u2705\u63a8\u8350<\/th><\/tr><\/thead><tbody><tr><td><strong>\u4e3b\u7ba1\u9053\u89c4\u683c<\/strong><\/td><td>De25<\/td><td><strong>De32<\/strong><\/td><\/tr><tr><td><strong>\u76d8\u7ba1\u89c4\u683c<\/strong><\/td><td>De16<\/td><td><strong>De20<\/strong><\/td><\/tr><tr><td><strong>\u6d41\u91cf\u80fd\u529b<\/strong><\/td><td>\u7ea6500 L\/h<\/td><td><strong>\u7ea6700-1,000 L\/h\uff08\u63d0\u534740%-100%\uff09<\/strong><\/td><\/tr><tr><td><strong>\u70ed\u4f20\u8f93\u80fd\u529b<\/strong><\/td><td>\u7ea65-6 kW<\/td><td><strong>\u7ea610 kW\uff08\u63d0\u534760%\u4ee5\u4e0a\uff09<\/strong><\/td><\/tr><tr><td><strong>\u9002\u7528\u91c7\u6696\u9762\u79ef<\/strong><\/td><td>\u226480\u33a1\u52c9\u5f3a\u53ef\u7528<\/td><td><strong>80-140\u33a1\u6b63\u5408\u9002<\/strong><\/td><\/tr><tr><td><strong>\u521d\u671f\u6210\u672c\u5dee\u5f02<\/strong><\/td><td>\u57fa\u51c6<\/td><td><strong>+\u7ea615\u5143\/\u33a1\uff0c85\u33a1\u7ea6+1,275\u5143<\/strong><\/td><\/tr><tr><td><strong>\u957f\u671f\u8fd0\u884c\u6210\u672c<\/strong><\/td><td>\u9ad8\uff08\u9891\u7e41\u542f\u505c\u3001\u9ad8\u6c34\u6e29\uff09<\/td><td><strong>\u4f4e\uff08\u4f4e\u6c34\u6e29\u3001\u7cfb\u7edf\u7a33\u5b9a\uff09<\/strong><\/td><\/tr><tr><td><strong>\u6548\u679c<\/strong><\/td><td>\u8fdc\u7aef\u53ef\u80fd\u4e0d\u70ed<\/td><td><strong>\u5168\u5c4b\u5747\u5300\u70ed\uff0c\u8fdc\u7aef\u4e5f\u70ed<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u60a8\u670b\u53cb\u5bb6\u5730\u6696\u201c\u5236\u70ed\u6548\u679c\u4e0d\u597d\u201d\uff0c\u6839\u6e90\u5f80\u5f80\u662f\u7ba1\u8def\u8bbe\u8ba1\u4e0d\u5408\u7406\uff0825+16\uff09\u3002<strong>\u5f3a\u70c8\u63a8\u835032+20\u8282\u80fd\u578b\u7ba1\u8def<\/strong>\uff0c\u521d\u6295\u8d44\u53ea\u591a\u7ea61,275\u5143\uff0c\u6bcf\u6708\u7701\u6c14100-200\u5143\uff0c\u4e00\u5e74\u534a\u5230\u4e24\u5e74\u56de\u672c\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u56db\u6b65\uff1a\u4e24\u5957\u5b8c\u6574\u65b9\u6848\u6c47\u603b<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u592e\u7a7a\u8c03<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u7ba1\u8def<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9884\u4f30\u603b\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u4eba\u7fa4<\/th><\/tr><\/thead><tbody><tr><td><strong>\u65b9\u6848\u4e00\uff1a\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u578b<\/strong><\/td><td>\u8212\u4eab125\u4e00\u62d6\u56db<\/td><td>\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696<\/td><td>\u745e\u7f8e16L\u70ed\u6c34\u5668<\/td><td>32+20\u8282\u80fd\u7ba1\u8def<\/td><td><strong>\u7ea64.8-5.3\u4e07<\/strong><\/td><td><strong>\u9884\u7b97\u4f18\u5148\u3001\u8ffd\u6c42\u70ed\u6c34\u7a33\u5b9a\u3001\u6027\u4ef7\u6bd4<\/strong><\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e8c\uff1a\u51b7\u51dd\u4e00\u4f53\u673a\u578b<\/strong><\/td><td>\u8212\u4eab125\u4e00\u62d6\u56db<\/td><td>\u83f2\u65af\u66fc24kW\u51b7\u51dd\u7089<\/td><td>\u9505\u7089\u81ea\u5e26<\/td><td>32+20\u8282\u80fd\u7ba1\u8def<\/td><td><strong>\u7ea65.3-<\/strong>5.8\u4e07<\/td><td>\u9884\u7b97\u5145\u8db3\u3001\u8ffd\u6c42\u8bbe\u5907\u7b80\u6d01<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e94\u6b65\uff1a\u5e38\u89c1\u7591\u95ee\u89e3\u7b54<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u53ef\u80fd\u60f3\u95ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u7b54<\/th><\/tr><\/thead><tbody><tr><td><strong>\u201c\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u4f1a\u4e0d\u4f1a\u592a\u590d\u6742\uff1f\u201d<\/strong><\/td><td>\u4e0d\u4f1a\u3002\u53ea\u9700\u8981\u5728\u71c3\u6c14\u7ba1\u9053\u4e0a\u505a\u4e00\u4e2a\u4e09\u901a\uff0c\u4e24\u53f0\u8bbe\u5907\u72ec\u7acb\u5b89\u88c5\u3002\u591a\u4e00\u53f0\u70ed\u6c34\u5668\u7684\u7a7a\u95f4\uff08\u7ea60.1\u33a1\uff09\uff0c\u6362\u6765\u7684\u662f10\u5e74\u7a33\u5b9a\u7684\u70ed\u6c34\u3002<\/td><\/tr><tr><td><strong>\u201c\u66fc\u745e\u5fb718kW\u591f\u7528\u5417\uff1f\u201d<\/strong><\/td><td>\u591f\u7528\u300285\u33a1\u5730\u6696\u6052\u6e29\u53ea\u97005-7kW\uff0c18kW\u7089\u5b50\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u5339\u914d\u7cbe\u51c6\uff0c\u4e0d\u9891\u7e41\u542f\u505c\u3002<\/td><\/tr><tr><td><strong>\u201c\u745e\u7f8e16L\u70ed\u6c34\u5668\u591f\u7528\u5417\uff1f\u201d<\/strong><\/td><td>\u591f\u7528\u300216L\u53ef\u6ee1\u8db3\u4e00\u53a8\u4e00\u536b\u540c\u65f6\u7528\u6c34\uff0c\u666e\u901a\u82b1\u6d128-10L\u5c31\u591f\u4e86\u3002\u60a8\u5bb63\u4eba\uff0c\u5b8c\u5168\u591f\u7528\u3002<\/td><\/tr><tr><td><strong>\u201c\u4e00\u4f53\u673a\u4e0d\u662f\u66f4\u7701\u4e8b\u5417\uff1f\u201d<\/strong><\/td><td>\u4e00\u4f53\u673a\u8bbe\u5907\u5c11\u3001\u5b89\u88c5\u7b80\u5355\u3002\u4f46\u4ee3\u4ef7\u662f\uff1a\u51ac\u5b63\u6d17\u6fa1\u6c34\u53d8\u5c0f\u3001\u590f\u5b63\u6c34\u8fc7\u70eb\u3001\u7ef4\u4fee\u65f6\u91c7\u6696\u548c\u70ed\u6c34\u5168\u505c\u3002\u5206\u79bb\u65b9\u6848\u8d35\u5728\u6709\u5907\u65e0\u60a3\u3002<\/td><\/tr><tr><td><strong>\u201c32+20\u7ba1\u8def\u591a\u82b11,275\u5143\u503c\u5f97\u5417\uff1f\u201d<\/strong><\/td><td>\u503c\u5f97\u3002\u6bcf\u6708\u7701100-200\u5143\u6c14\u8d39\uff0c\u4e00\u5e74\u534a\u5230\u4e24\u5e74\u56de\u672c\uff0c\u4e4b\u540e\u6bcf\u5e74\u7eaf\u7701\u3002\u800c\u4e14\u8fdc\u7aef\u4e0d\u70ed\u7684\u6839\u6e90\u5c31\u662f\u7ba1\u5f84\u5c0f\u4e86\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u516d\u6b65\uff1a\u4e00\u53e5\u8bdd\u603b\u7ed3<\/h2>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u4efb\u5973\u58eb\uff0c\u60a8\u5bb6125\u33a1\uff0c\u4e2d\u592e\u7a7a\u8c03\u9009\u8212\u4eab125\u4e00\u62d6\u56db\uff08\u8d85\u914d\u7387128.8%\u5408\u7406\uff0c\u4e3b\u5367\u914d40\u578b\u5236\u51b7\u66f4\u5feb\uff09\u3002\u5730\u6696\u548c\u70ed\u6c34\u63a8\u8350\u201c\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u201d\u65b9\u6848\uff1a\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\uff08\u4e13\u4f9b\u5730\u6696\uff09+\u745e\u7f8e16L\u70ed\u6c34\u5668\uff08\u4e13\u4f9b\u6d17\u6fa1\uff09+32+20\u5927\u6d41\u91cf\u7ba1\u8def\u3002\u6bd4\u4e00\u4f53\u673a\u77018,000-11,000\u5143\uff0c\u4e14\u70ed\u6c34\u7a33\u5b9a\u3001\u91c7\u6696\u4e0d\u62a2\u529f\u7387\u3001\u7ef4\u4fee\u4e92\u4e0d\u5f71\u54cd\u3002\u603b\u4ef7\u63a7\u5236\u57284.8-5.3\u4e07\u3002<\/strong><\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u524d\u4e66\u7ed3\u675f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u9700\u7cbe\u786e\u62a5\u4ef7\u5355\uff08\u542b\u8bbe\u5907\u660e\u7ec6\u3001\u5b89\u88c5\u8d39\u3001\u8f85\u6750\u8d39\uff09\uff0c\u8bf7\u786e\u8ba4\u65b9\u6848\u65b9\u5411\u540e\uff0c\u6211\u4e3a\u60a8\u51fa\u8be6\u7ec6\u62a5\u4ef7\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\uff1a\u4efb\u5973\u58eb\u6237\u578b\u6982\u51b5\uff1a125\u33a1\u4e09\u5ba4\uff0c\u5e38\u4f4f [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2718","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2718\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5ba2\u6237\uff1a\u4efb\u5973\u58eb\u6237\u578b\u6982\u51b5\uff1a125\u33a1\u4e09\u5ba4\uff0c\u5e38\u4f4f [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2718\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-23T03:13:18+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2718\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2718\",\"name\":\"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-09T09:09:38+00:00\",\"dateModified\":\"2026-10-23T03:13:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2718#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2718\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2718#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2718","og_locale":"zh_CN","og_type":"article","og_title":"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5ba2\u6237\uff1a\u4efb\u5973\u58eb\u6237\u578b\u6982\u51b5\uff1a125\u33a1\u4e09\u5ba4\uff0c\u5e38\u4f4f [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2718","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-23T03:13:18+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2718","url":"https:\/\/longmai-nt.com\/?page_id=2718","name":"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-09T09:09:38+00:00","dateModified":"2026-10-23T03:13:18+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2718#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2718"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2718#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4efb\u5973\u58eb\u00b7\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34 \u65b9\u6848\u524d\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2718","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2718"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2718\/revisions"}],"predecessor-version":[{"id":16234,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2718\/revisions\/16234"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}