{"id":2782,"date":"2026-06-09T22:45:33","date_gmt":"2026-06-09T14:45:33","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2782"},"modified":"2026-10-10T15:05:37","modified_gmt":"2026-10-10T07:05:37","slug":"%e6%97%a5%e7%ab%8bex-%e8%88%92%e4%ba%ab%e5%a4%a7%e5%ae%b9%e9%87%8f180224%e5%9e%8b%e5%8f%8c%e9%a3%8e%e6%89%87%e7%b3%bb%e5%88%97","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2782","title":{"rendered":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217"},"content":{"rendered":"\n\n<style>\n  \/* ===== CSS Variables ===== *\/\n  :root {\n    --dark: #1a2332;\n    --dark2: #243447;\n    --brand-red: #c0392b;\n    --brand-red-light: #e74c3c;\n    --gold: #e8b44a;\n    --gold-light: #f0c674;\n    --green: #27ae60;\n    --green-light: #2ecc71;\n    --blue: #2980b9;\n    --blue-light: #3498db;\n    --bg: #f0f2f5;\n    --card: #ffffff;\n    --text: #2c3e50;\n    --text2: #5a6a7e;\n    --text3: #7f8c9b;\n    --border: #e2e6ec;\n    --radius: 14px;\n    --radius-sm: 8px;\n    --shadow: 0 2px 14px rgba(0,0,0,.05);\n    --shadow-md: 0 4px 20px rgba(0,0,0,.08);\n    --transition: all .3s ease;\n  }\n\n  \/* ===== Reset & Base ===== *\/\n  *,*::before,*::after{margin:0;padding:0;box-sizing:border-box}\n  html{scroll-behavior:smooth;font-size:16px;scroll-padding-top:80px}\n  body{\n    font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",\"Helvetica Neue\",sans-serif;\n    background:var(--bg);color:var(--text);line-height:1.75;\n    -webkit-font-smoothing:antialiased;\n  }\n\n  \/* ===== Progress Bar ===== *\/\n  .progress-bar{\n    position:fixed;top:0;left:0;height:3px;\n    background:linear-gradient(90deg,var(--brand-red),var(--gold));\n    z-index:1000;transition:width .1s linear;\n  }\n\n  \/* ===== Smart Slider TOC ===== *\/\n  .sb{\n    position:fixed;left:0;top:0;width:240px;height:100vh;\n    background:linear-gradient(180deg,var(--dark),var(--dark2));\n    padding:28px 0;z-index:100;overflow-y:auto;overflow-x:hidden;\n    display:flex;flex-direction:column;\n    scrollbar-width:thin;scrollbar-color:rgba(255,255,255,.1) transparent;\n  }\n  .sb::-webkit-scrollbar{width:4px}\n  .sb::-webkit-scrollbar-thumb{background:rgba(255,255,255,.1);border-radius:2px}\n\n  .sb-brand{padding:0 20px 22px;border-bottom:1px solid rgba(255,255,255,.08);margin-bottom:14px}\n  .sb-brand .logo{font-size:14px;font-weight:700;color:var(--gold);letter-spacing:1px}\n  .sb-brand .sub{font-size:11px;color:rgba(255,255,255,.4);margin-top:3px;line-height:1.5}\n  .sb-brand .sub span{display:block;margin-top:2px;color:rgba(255,255,255,.25);font-size:10px}\n\n  .nl{list-style:none;flex:1;padding:0}\n  .ni{padding:11px 20px;cursor:pointer;transition:var(--transition);border-left:3px solid transparent;display:flex;align-items:center;gap:10px}\n  .ni:hover{background:rgba(255,255,255,.05)}\n  .ni.active{background:rgba(232,180,74,.12);border-left-color:var(--gold)}\n  .ni .nn{\n    display:flex;align-items:center;justify-content:center;\n    width:22px;height:22px;min-width:22px;line-height:22px;\n    border-radius:50%;font-size:10px;font-weight:700;\n    background:rgba(255,255,255,.08);color:rgba(255,255,255,.45);\n    transition:var(--transition);\n  }\n  .ni.active .nn{background:var(--gold);color:var(--dark)}\n  .ni .nt{font-size:12px;color:rgba(255,255,255,.5);transition:var(--transition);line-height:1.4}\n  .ni.active .nt{color:#f0f0f0;font-weight:600}\n  .ni .ni-sub{font-size:10px;color:rgba(255,255,255,.3);margin-left:auto;display:none}\n  .ni.active .ni-sub{display:inline}\n\n  .sb-ft{padding:14px 20px;border-top:1px solid rgba(255,255,255,.06);font-size:10px;color:rgba(255,255,255,.2)}\n  .sb-ft a{color:rgba(255,255,255,.3);text-decoration:none;transition:var(--transition)}\n  .sb-ft a:hover{color:var(--gold)}\n\n  \/* ===== Main Content ===== *\/\n  .mc{margin-left:240px;min-height:100vh}\n\n  \/* ===== Image Styles ===== *\/\n  .img-responsive{width:100%;height:auto;display:block;border-radius:8px}\n  .img-shadow{box-shadow:0 4px 20px rgba(0,0,0,.1)}\n  .img-caption{font-size:12px;color:var(--text3);text-align:center;margin-top:8px;line-height:1.5}\n\n  \/* ===== Hero ===== *\/\n  .hero{\n    background:linear-gradient(135deg,var(--dark) 0%,#2c3e50 50%,#34495e 100%);\n    color:#fff;padding:56px 56px 48px;position:relative;overflow:hidden;\n  }\n  .hero-grid{display:flex;align-items:center;gap:40px;position:relative;z-index:1}\n  .hero-text{flex:1;min-width:0}\n  .hero-img{flex-shrink:0;width:380px}\n  .hero-img img{width:100%;height:auto;border-radius:12px;box-shadow:0 8px 32px rgba(0,0,0,.3)}\n  @media(max-width:860px){.hero-grid{flex-direction:column}.hero-img{width:100%;max-width:400px}}\n  .hero::before{\n    content:'';position:absolute;top:-30%;right:-10%;\n    width:500px;height:500px;\n    background:radial-gradient(circle,rgba(232,180,74,.1) 0%,rgba(192,57,43,.06) 50%,transparent 70%);\n    pointer-events:none;\n  }\n  .hero::after{\n    content:'';position:absolute;bottom:0;left:0;right:0;height:4px;\n    background:linear-gradient(90deg,var(--brand-red),var(--gold),var(--brand-red));\n  }\n  .hero-tag{\n    display:inline-block;background:var(--brand-red);color:#fff;\n    font-size:12px;font-weight:700;padding:5px 14px;border-radius:4px;\n    letter-spacing:1px;margin-bottom:20px;position:relative;z-index:1;\n  }\n  .hero-title{\n    font-size:34px;font-weight:800;line-height:1.3;margin-bottom:14px;\n    position:relative;z-index:1;\n  }\n  .hero-title .hl-green{color:var(--green-light)}\n  .hero-sub{\n    font-size:16px;color:rgba(255,255,255,.55);line-height:1.7;\n    max-width:720px;position:relative;z-index:1;\n  }\n  .hero-metrics{\n    display:flex;gap:20px;margin-top:28px;position:relative;z-index:1;flex-wrap:wrap;\n  }\n  .hm-item{\n    background:rgba(255,255,255,.06);border:1px solid rgba(255,255,255,.1);\n    border-radius:10px;padding:14px 20px;text-align:center;min-width:100px;\n    backdrop-filter:blur(10px);transition:var(--transition);\n  }\n  .hm-item:hover{background:rgba(255,255,255,.1);border-color:rgba(255,255,255,.2)}\n  .hm-val{font-size:22px;font-weight:800;color:var(--gold);line-height:1.2}\n  .hm-label{font-size:11px;color:rgba(255,255,255,.5);margin-top:3px}\n\n  \/* ===== Content Container ===== *\/\n  .cv{max-width:960px;margin:0 auto;padding:44px 40px 80px}\n\n  \/* ===== Section ===== *\/\n  .sec{margin-bottom:52px}\n  .sh{\n    display:flex;align-items:center;gap:14px;margin-bottom:24px;\n    padding-bottom:14px;border-bottom:2px solid var(--gold);\n  }\n  .snum{\n    display:flex;align-items:center;justify-content:center;\n    width:38px;height:38px;background:var(--dark);color:var(--gold);\n    font-size:16px;font-weight:800;border-radius:8px;flex-shrink:0;\n  }\n  .stitle{font-size:22px;font-weight:700;color:var(--dark)}\n  .stitle-sub{font-size:14px;color:var(--text3);font-weight:400;margin-left:10px}\n\n  \/* ===== Cards ===== *\/\n  .card{\n    background:var(--card);border-radius:var(--radius);\n    padding:26px 30px;box-shadow:var(--shadow);margin-bottom:18px;\n    transition:var(--transition);\n  }\n  .card:hover{box-shadow:var(--shadow-md)}\n  .ct{\n    font-size:16px;font-weight:700;color:var(--dark);\n    margin-bottom:16px;display:flex;align-items:center;gap:8px;\n  }\n  .ct .ct-ico{font-size:20px}\n\n  \/* ===== Tables ===== *\/\n  .dt{width:100%;border-collapse:collapse;margin-top:8px;font-size:13px}\n  .dt th{\n    text-align:center;padding:10px 6px;background:#f7f8fa;\n    font-size:11px;font-weight:700;color:var(--text2);\n    border-bottom:2px solid var(--border);white-space:nowrap;\n  }\n  .dt td{\n    text-align:center;padding:10px 6px;border-bottom:1px solid #f0f2f5;\n    font-size:12px;line-height:1.5;\n  }\n  .dt tr:last-child td{border-bottom:none}\n  .dt tr:nth-child(even) td{background:#fafbfc}\n  .dt .label{text-align:left;color:var(--text3);font-weight:600;padding-left:12px;font-size:12px}\n  .dt .hl-g{background:rgba(39,174,96,.06) !important;color:#1e8449;font-weight:700}\n  .dt .hl-b{background:rgba(52,152,219,.06) !important;color:#1a5276;font-weight:700}\n  .dt .hl-y{background:rgba(232,180,74,.06) !important;color:#8b6914;font-weight:700}\n  .dt .hl-r{background:rgba(192,57,43,.06) !important;color:#922b21;font-weight:700}\n  .dt .series-h th{font-size:12px;padding:8px 6px;color:#fff}\n  .dt .series-h.sh-g th{background:var(--green)}\n  .dt .series-h.sh-b th{background:var(--blue);color:#fff}\n  .dt .series-h.sh-y th{background:var(--gold);color:var(--dark)}\n  .dt .diff{font-size:11px;font-weight:700}\n  .dt .diff.up{color:var(--brand-red)}\n  .dt .diff.down{color:var(--green)}\n\n  \/* ===== Ratio Bar ===== *\/\n  .ratio-bar{display:flex;align-items:center;gap:8px;margin:5px 0}\n  .rb-track{height:24px;background:#f0f2f5;border-radius:6px;flex:1;overflow:hidden}\n  .rb-fill{\n    height:100%;border-radius:6px;display:flex;align-items:center;\n    justify-content:flex-end;padding-right:10px;\n    font-size:11px;font-weight:700;color:#fff;min-width:40px;\n  }\n  .rb-fill.green{background:linear-gradient(90deg,var(--green),var(--green-light))}\n  .rb-fill.blue{background:linear-gradient(90deg,var(--blue),var(--blue-light))}\n  .rb-fill.gold{background:linear-gradient(90deg,var(--gold),var(--gold-light))}\n  .rb-val{font-size:13px;font-weight:700;min-width:36px}\n  .rb-val.green{color:var(--green)}.rb-val.blue{color:var(--blue)}.rb-val.gold{color:var(--gold)}\n\n  \/* ===== Timeline ===== *\/\n  .timeline{position:relative;padding-left:36px}\n  .timeline::before{\n    content:'';position:absolute;left:11px;top:4px;\n    width:2px;height:calc(100% - 8px);\n    background:linear-gradient(180deg,var(--brand-red),var(--gold),var(--green));\n    border-radius:1px;\n  }\n  .tl-item{position:relative;margin-bottom:28px}\n  .tl-item::before{\n    content:'';position:absolute;left:-29px;top:6px;\n    width:14px;height:14px;border-radius:50%;\n    background:var(--card);border:3px solid var(--brand-red);\n  }\n  .tl-item.highlight::before{\n    background:var(--brand-red);border-color:var(--brand-red);\n    box-shadow:0 0 0 4px rgba(192,57,43,.2);\n  }\n  .tl-item.gold::before{border-color:var(--gold)}\n  .tl-item.green::before{border-color:var(--green)}\n  .tl-year{\n    font-size:13px;font-weight:800;color:var(--brand-red);\n    margin-bottom:4px;letter-spacing:.5px;\n  }\n  .tl-item.gold .tl-year{color:var(--gold)}\n  .tl-item.green .tl-year{color:var(--green)}\n  .tl-title{font-size:16px;font-weight:700;color:var(--dark);margin-bottom:4px}\n  .tl-desc{font-size:13px;color:var(--text2);line-height:1.7}\n\n  \/* ===== Insight Boxes ===== *\/\n  .insight{\n    border-radius:10px;padding:18px 24px;margin:16px 0;\n    font-size:14px;line-height:1.8;\n  }\n  .insight.green{\n    background:linear-gradient(135deg,#eafaf1,#d5f5e3);\n    border-left:4px solid var(--green);color:#1e6b3a;\n  }\n  .insight.blue{\n    background:linear-gradient(135deg,#e8f4fd,#d6ecfa);\n    border-left:4px solid var(--blue);color:#1a5276;\n  }\n  .insight.gold{\n    background:linear-gradient(135deg,#fff8e1,#fff3cd);\n    border-left:4px solid var(--gold);color:#6b5a1e;\n  }\n  .insight.red{\n    background:linear-gradient(135deg,#fef3f2,#fde8e6);\n    border-left:4px solid var(--brand-red);color:#6b3a38;\n  }\n  .insight .it{font-size:14px;font-weight:700;margin-bottom:8px}\n\n  \/* ===== Gradient Card ===== *\/\n  .gradient-card{\n    background:var(--card);border-radius:var(--radius);\n    padding:24px 28px;box-shadow:var(--shadow);margin-bottom:14px;\n    border-top:3px solid var(--gold);\n  }\n  .gradient-card .gc-title{font-size:15px;font-weight:700;color:var(--dark);margin-bottom:12px}\n  .gradient-card .gc-row{display:flex;align-items:center;gap:14px;font-size:14px;margin-bottom:10px}\n  .gradient-card .gc-arrow{color:var(--gold);font-weight:700;font-size:18px}\n  .gradient-card .gc-val{font-weight:700;color:var(--brand-red)}\n  .gradient-card .gc-note{font-size:13px;color:var(--text3);margin-top:8px;line-height:1.7}\n\n  \/* ===== Tech Cards ===== *\/\n  .tech-grid{display:grid;grid-template-columns:1fr 1fr;gap:18px}\n  .tech-card{\n    background:var(--card);border-radius:var(--radius);\n    padding:24px 22px;box-shadow:var(--shadow);\n    border-top:3px solid var(--blue);transition:var(--transition);\n  }\n  .tech-card:hover{box-shadow:var(--shadow-md);transform:translateY(-2px)}\n  .tech-card .tc-icon{font-size:28px;margin-bottom:10px}\n  .tech-card .tc-title{font-size:15px;font-weight:700;color:var(--dark);margin-bottom:8px}\n  .tech-card .tc-desc{font-size:13px;color:var(--text2);line-height:1.8}\n\n  \/* ===== Recommendation Grid ===== *\/\n  .rec-grid{display:grid;grid-template-columns:1fr 1fr;gap:18px;margin:16px 0}\n  .rec-card{border-radius:var(--radius);padding:26px 22px}\n  .rec-card.r1{background:linear-gradient(135deg,#eafaf1,#d5f5e3);border:2px solid var(--green)}\n  .rec-card.r2{background:linear-gradient(135deg,#fef3cd,#fff8e1);border:2px solid var(--gold)}\n  .rc-icon{font-size:30px;margin-bottom:10px}\n  .rc-type{font-size:13px;font-weight:700;margin-bottom:6px}\n  .rec-card.r1 .rc-type{color:#1e8449}.rec-card.r2 .rc-type{color:#8b6914}\n  .rc-series{font-size:18px;font-weight:800;margin-bottom:12px}\n  .rec-card.r1 .rc-series{color:var(--green)}.rec-card.r2 .rc-series{color:var(--gold)}\n  .rc-reason{font-size:13px;color:var(--text2);line-height:1.8}\n  .rc-reason strong{color:var(--dark)}\n\n  \/* ===== Summary Card ===== *\/\n  .sum-card{\n    background:linear-gradient(135deg,var(--dark),#2c3e50);\n    border-radius:16px;padding:30px 34px;color:#fff;\n  }\n  .sum-card .sc-title{font-size:17px;font-weight:700;color:var(--gold);margin-bottom:18px}\n  .sum-card .sc-item{display:flex;align-items:flex-start;gap:14px;margin-bottom:14px;font-size:14px;color:rgba(255,255,255,.75);line-height:1.7}\n  .sum-card .sc-item .sc-ic{font-size:20px;flex-shrink:0;margin-top:2px}\n  .sum-card .sc-item strong{color:#fff}\n\n  \/* ===== Scope Note ===== *\/\n  .scope{\n    background:#f7f8fa;border-radius:10px;padding:18px 22px;\n    margin-bottom:20px;font-size:13px;color:var(--text3);line-height:1.7;\n  }\n  .scope strong{color:var(--dark)}\n\n  \/* ===== FAQ ===== *\/\n  .faq-item{margin-bottom:12px}\n  .faq-q{\n    background:var(--card);border-radius:var(--radius-sm);\n    padding:16px 22px;cursor:pointer;font-size:15px;font-weight:600;\n    color:var(--dark);box-shadow:var(--shadow);\n    display:flex;align-items:center;gap:12px;\n    transition:var(--transition);border-left:3px solid transparent;\n  }\n  .faq-q:hover{border-left-color:var(--gold);background:#fafbfc}\n  .faq-q.open{border-left-color:var(--brand-red);background:#fef9f9}\n  .faq-q .faq-arrow{transition:transform .3s;color:var(--text3);font-size:12px}\n  .faq-q.open .faq-arrow{transform:rotate(180deg);color:var(--brand-red)}\n  .faq-a{\n    background:var(--card);border-radius:0 0 var(--radius-sm) var(--radius-sm);\n    padding:0 22px;max-height:0;overflow:hidden;\n    transition:max-height .4s ease,padding .4s ease;\n    font-size:14px;color:var(--text2);line-height:1.8;\n  }\n  .faq-q.open + .faq-a{max-height:500px;padding:18px 22px}\n\n  \/* ===== CTA Section ===== *\/\n  .cta-section{\n    background:linear-gradient(135deg,var(--dark),#2c3e50);\n    border-radius:16px;padding:36px 40px;color:#fff;text-align:center;\n    margin-top:10px;\n  }\n  .cta-section h3{font-size:20px;font-weight:700;color:var(--gold);margin-bottom:16px}\n  .cta-section p{font-size:15px;color:rgba(255,255,255,.6);margin-bottom:20px;line-height:1.7}\n  .cta-btn{\n    display:inline-block;background:var(--brand-red);color:#fff;\n    padding:12px 32px;border-radius:8px;font-size:15px;font-weight:700;\n    text-decoration:none;transition:var(--transition);\n  }\n  .cta-btn:hover{background:var(--brand-red-light);transform:translateY(-1px)}\n\n  \/* ===== Store Info ===== *\/\n  .store-grid{display:grid;grid-template-columns:1fr 1fr;gap:18px;margin:16px 0}\n  .store-card{\n    background:var(--card);border-radius:var(--radius);\n    padding:22px 24px;box-shadow:var(--shadow);\n  }\n  .store-card .sn{font-size:15px;font-weight:700;color:var(--dark);margin-bottom:8px}\n  .store-card .sa{font-size:13px;color:var(--text2);margin-bottom:4px}\n  .store-card .sp{font-size:13px;color:var(--text3)}\n\n  \/* ===== Nav Cards ===== *\/\n  .nav-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:16px}\n  .nav-card{\n    background:var(--card);border-radius:var(--radius);\n    padding:22px 20px;box-shadow:var(--shadow);\n    text-decoration:none;color:var(--text);\n    transition:var(--transition);border:1px solid transparent;\n    display:flex;align-items:flex-start;gap:12px;\n  }\n  .nav-card:hover{\n    box-shadow:var(--shadow-md);border-color:var(--gold);\n    transform:translateY(-2px);\n  }\n  .nav-card .nc-icon{font-size:24px;flex-shrink:0;margin-top:2px}\n  .nav-card .nc-title{font-size:14px;font-weight:700;color:var(--dark);margin-bottom:4px}\n  .nav-card .nc-desc{font-size:12px;color:var(--text3);line-height:1.5}\n\n  \/* ===== Case Placeholder ===== *\/\n  .case-placeholder{\n    background:var(--card);border-radius:var(--radius);\n    border:2px dashed var(--border);padding:40px 30px;text-align:center;\n    transition:var(--transition);\n  }\n  .case-placeholder:hover{border-color:var(--gold)}\n  .case-placeholder .cp-icon{font-size:40px;margin-bottom:12px}\n  .case-placeholder .cp-title{font-size:16px;font-weight:700;color:var(--dark);margin-bottom:8px}\n  .case-placeholder .cp-desc{font-size:14px;color:var(--text3);line-height:1.7;max-width:500px;margin:0 auto}\n\n  \/* ===== Footer ===== *\/\n  .page-footer{\n    background:var(--dark);color:rgba(255,255,255,.4);\n    padding:28px 40px;font-size:12px;line-height:1.8;\n    margin-left:240px;\n  }\n  .page-footer a{color:rgba(255,255,255,.5);text-decoration:none;transition:var(--transition)}\n  .page-footer a:hover{color:var(--gold)}\n  .page-footer .pf-row{display:flex;flex-wrap:wrap;gap:8px 20px;margin-bottom:12px}\n  .page-footer .pf-divider{color:rgba(255,255,255,.15);margin:0 4px}\n  .page-footer .pf-bottom{border-top:1px solid rgba(255,255,255,.06);padding-top:14px;margin-top:14px}\n\n  \/* ===== Mobile TOC Toggle ===== *\/\n  .mob-toc-toggle{\n    display:none;position:fixed;bottom:24px;right:24px;z-index:200;\n    width:48px;height:48px;border-radius:50%;\n    background:var(--dark);color:var(--gold);border:none;\n    font-size:22px;cursor:pointer;box-shadow:0 4px 16px rgba(0,0,0,.3);\n    align-items:center;justify-content:center;\n  }\n\n  \/* ===== Responsive ===== *\/\n  @media(max-width:960px){\n    .sb{transform:translateX(-100%);transition:transform .3s}\n    .sb.open{transform:translateX(0);box-shadow:4px 0 20px rgba(0,0,0,.3)}\n    .mc{margin-left:0}\n    .hero{padding:36px 22px 32px}\n    .hero-title{font-size:26px}\n    .hero-metrics{gap:10px}\n    .hm-item{padding:10px 14px;min-width:80px}\n    .hm-val{font-size:18px}\n    .cv{padding:32px 18px 60px}\n    .tech-grid{grid-template-columns:1fr}\n    .rec-grid{grid-template-columns:1fr}\n    .store-grid{grid-template-columns:1fr}\n    .nav-grid{grid-template-columns:1fr 1fr}\n    .mob-toc-toggle{display:flex}\n    .page-footer{margin-left:0;padding:22px 20px}\n    .sh{gap:10px}\n    .stitle{font-size:19px}\n  }\n\n  @media(max-width:600px){\n    .hero-title{font-size:22px}\n    .hero-metrics{flex-wrap:wrap}\n    .nav-grid{grid-template-columns:1fr}\n    .dt{font-size:10px}.dt th,.dt td{padding:6px 3px}\n  }\n\n  \/* ===== Collapse \/ Slider Toggles ===== *\/\n  .collapse-toggle {\n    display: inline-flex; align-items: center; gap: 8px;\n    cursor: pointer; user-select: none;\n    color: var(--dark); font-size: 14px; font-weight: 700;\n    padding: 8px 18px; border-radius: 6px;\n    border: 2px solid var(--dark);\n    background: transparent;\n    transition: var(--transition);\n    margin-bottom: 12px;\n  }\n  .collapse-toggle:hover {\n    background: var(--dark); color: var(--gold);\n  }\n  .collapse-toggle .ct-arrow {\n    display: inline-block; transition: transform .35s ease;\n    font-size: 11px; margin-left: 2px;\n  }\n  .collapse-toggle.open .ct-arrow {\n    transform: rotate(180deg);\n  }\n  .collapse-wrap {\n    overflow: hidden;\n    transition: max-height .5s ease, opacity .4s ease;\n  }\n  .collapse-wrap.collapsed {\n    max-height: 0 !important; opacity: 0;\n  }\n  \/* Tech grid expand *\/\n  .tech-expand-btn {\n    display: inline-flex; align-items: center; gap: 8px;\n    cursor: pointer; user-select: none;\n    font-size: 14px; font-weight: 700;\n    padding: 10px 24px; border-radius: 8px;\n    border: 2px solid var(--gold);\n    background: var(--gold); color: var(--dark);\n    transition: var(--transition);\n    margin-top: 10px;\n  }\n  .tech-expand-btn:hover {\n    background: var(--dark); color: var(--gold);\n    border-color: var(--dark);\n  }\n  .tech-expand-btn .te-arrow {\n    display: inline-block; transition: transform .35s ease;\n  }\n  .tech-expand-btn.open .te-arrow {\n    transform: rotate(180deg);\n  }\n  .tech-card.tech-hidden {\n    display: none;\n  }\n  .tech-card.tech-show {\n    display: block;\n    animation: techFadeIn .45s ease forwards;\n  }\n  @keyframes techFadeIn {\n    from { opacity: 0; transform: translateY(10px); }\n    to { opacity: 1; transform: translateY(0); }\n  }\n\n<\/style>\n\n<!-- Progress Bar -->\n<div class=\"progress-bar\" id=\"progressBar\"><\/div>\n\n<!-- Smart Slider TOC -->\n<nav class=\"sb\" id=\"sidebarToc\">\n  <div class=\"sb-brand\">\n    <div class=\"logo\">\u9f99\u8109\u6696\u901a<\/div>\n    <div class=\"sub\">\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u6247<span>180~224\u578b \u00b7 \u5b8c\u6574\u8be6\u60c5\u9875<\/span><\/div>\n  <\/div>\n  <ul class=\"nl\">\n    <li class=\"ni active\" data-target=\"s1\"><span class=\"nn\">1<\/span><span class=\"nt\">\u4ea7\u54c1\u53d1\u5c55\u53f2<\/span><\/li>\n    <li class=\"ni\" data-target=\"s2\"><span class=\"nn\">2<\/span><span class=\"nt\">\u5b9a\u4f4d\u4e0e\u6838\u5fc3\u4f18\u52bf<\/span><\/li>\n    <li class=\"ni\" data-target=\"s3\"><span class=\"nn\">3<\/span><span class=\"nt\">\u9002\u7528\u6237\u578b\u4e0e\u9762\u79ef<\/span><\/li>\n    <li class=\"ni\" data-target=\"s4\"><span class=\"nn\">4<\/span><span class=\"nt\">\u6838\u5fc3\u6280\u672f\u53c2\u6570<\/span><\/li>\n    <li class=\"ni\" data-target=\"s5\"><span class=\"nn\">5<\/span><span class=\"nt\">\u516d\u5927\u6838\u5fc3\u6280\u672f<\/span><\/li>\n    <li class=\"ni\" data-target=\"s6\"><span class=\"nn\">6<\/span><span class=\"nt\">vs \u5c0a\u777f\u5168\u6548\u5bf9\u6bd4<\/span><\/li>\n    <li class=\"ni\" data-target=\"s7\"><span class=\"nn\">7<\/span><span class=\"nt\">\u7075\u6d3b\u8bbe\u8ba1\u4e0e\u5b89\u88c5<\/span><\/li>\n    <li class=\"ni\" data-target=\"s8\"><span class=\"nn\">8<\/span><span class=\"nt\">\u667a\u80fd\u63a7\u5236\u4e0e\u51c0\u5316<\/span><\/li>\n    <li class=\"ni\" data-target=\"s9\"><span class=\"nn\">9<\/span><span class=\"nt\">\u5ba4\u5185\u673a\u9009\u578b\u53c2\u8003<\/span><\/li>\n    <li class=\"ni\" data-target=\"s10\"><span class=\"nn\">10<\/span><span class=\"nt\">\u5ba2\u6237\u6848\u4f8b\u5206\u4eab<\/span><\/li>\n    <li class=\"ni\" data-target=\"s11\"><span class=\"nn\">11<\/span><span class=\"nt\">\u4ea7\u54c1\u5bfc\u822a<\/span><\/li>\n    <li class=\"ni\" data-target=\"s12\"><span class=\"nn\">12<\/span><span class=\"nt\">\u5e38\u89c1\u95ee\u9898FAQ<\/span><\/li>\n  <\/ul>\n  <div class=\"sb-ft\">\u00a9 \u9f99\u8109\u6696\u901a \u00b7 2004-2026<br><a href=\"\/\">\u8fd4\u56de\u9996\u9875<\/a><\/div>\n<\/nav>\n\n<!-- Mobile TOC Toggle -->\n<button class=\"mob-toc-toggle\" id=\"mobTocToggle\" aria-label=\"\u76ee\u5f55\">\u2630<\/button>\n\n<!-- Main Content -->\n<div class=\"mc\">\n\n<!-- ===== HERO ===== -->\n<header class=\"hero\">\n  <div class=\"hero-grid\">\n    <div class=\"hero-text\">\n      <div class=\"hero-tag\">\u65e5\u7acbEX \u00b7 \u5927\u5bb9\u91cf\u53cc\u98ce\u6247 180~224\u578b<\/div>\n      <h1 class=\"hero-title\">\n        \u65e5\u7acbEX-<span class=\"hl-green\">\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u6247<\/span>\u7cfb\u5217<br>\u9002\u914d140~200\u33a1\u5927\u7a7a\u95f4 \u00b7 \u53cc\u98ce\u6247\u5f3a\u52b2\u6392\u98ce\n      <\/h1>\n      <p class=\"hero-sub\">\n        \u65b0\u4e00\u4ee3\u9ad8\u6548\u538b\u7f29\u673a + \u5168\u76f4\u6d41\u53d8\u9891\u6280\u672f\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\u300252\u2103\u6781\u7aef\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c-20\u2103\u4f4e\u6e29\u5f3a\u52b2\u5236\u70ed\u3002\u4e13\u5229\u51b7\u5a92\u788e\u6ce1\u6280\u672f\uff0c\u5ba4\u5185\u673a\u6700\u4f4e17dB\u6781\u81f4\u9759\u97f3\u3002320mm\u7d27\u51d1\u673a\u8eab\uff0c0\/30Pa\u9759\u538b\u53ef\u8c03\uff0c\u4e00\u62d612\u5927\u6237\u65b9\u6848\u3002\n      <\/p>\n      <div class=\"hero-metrics\">\n        <div class=\"hm-item\"><div class=\"hm-val\">APF 5.05<\/div><div class=\"hm-label\">\u8d85\u4e00\u7ea7\u80fd\u6548<\/div><\/div>\n        <div class=\"hm-item\"><div class=\"hm-val\">52\u2103<\/div><div class=\"hm-label\">\u9ad8\u6e29\u5236\u51b7<\/div><\/div>\n        <div class=\"hm-item\"><div class=\"hm-val\">17dB<\/div><div class=\"hm-label\">\u6781\u81f4\u9759\u97f3<\/div><\/div>\n        <div class=\"hm-item\"><div class=\"hm-val\">320mm<\/div><div class=\"hm-label\">\u7d27\u51d1\u673a\u8eab<\/div><\/div>\n        <div class=\"hm-item\"><div class=\"hm-val\">0\/30Pa<\/div><div class=\"hm-label\">\u9759\u538b\u53ef\u8c03<\/div><\/div>\n        <div class=\"hm-item\"><div class=\"hm-val\">\u4e00\u62d612<\/div><div class=\"hm-label\">\u5927\u6237\u65b9\u6848<\/div><\/div>\n      <\/div>\n    <\/div>\n    <div class=\"hero-img\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg\" alt=\"\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u5916\u673a\u5b9e\u666f\">\n    <\/div>\n  <\/div>\n<\/header>\n\n<div class=\"cv\">\n\n<!-- ===== \u00a71 \u4ea7\u54c1\u53d1\u5c55\u53f2 ===== -->\n<section class=\"sec\" id=\"s1\">\n  <div class=\"sh\"><div class=\"snum\">1<\/div><h2 class=\"stitle\">\u4ea7\u54c1\u53d1\u5c55\u53f2<\/h2><span class=\"stitle-sub\">\u4ece\u6280\u672f\u79ef\u7d2f\u5230\u8212\u4eab\u53cc\u98ce\u6247\u7684\u8fdb\u5316\u4e4b\u8def<\/span><\/div>\n\n  <div style=\"display:flex;gap:20px;align-items:flex-start;margin-bottom:18px;flex-wrap:wrap\">\n    <div class=\"insight blue\" style=\"flex:1;min-width:300px\">\n      <div class=\"it\">\u4ece\u6280\u672f\u79ef\u7d2f\u5230\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u7684\u8fdb\u5316\u4e4b\u8def<\/div>\n      \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5728\u53d8\u9891\u591a\u8054\u673a\u9886\u57df\u62e5\u6709\u8d85\u8fc730\u5e74\u7684\u6280\u672f\u79ef\u7d2f\u3002\u8212\u4eab\u53cc\u98ce\u6247\u7cfb\u5217\u662f\u5728EX\u5e73\u53f0\u4e0a\u6301\u7eed\u8fed\u4ee3\u7684\u6210\u679c\u2014\u2014\u4ece\u5355\u98ce\u6247\u5230\u53cc\u98ce\u6247\u3001\u4ece\u5c0f\u5bb9\u91cf\u5230\u5927\u5bb9\u91cf\uff0c\u6bcf\u4e00\u6b65\u90fd\u662f\u57fa\u4e8e\u4e2d\u56fd\u5bb6\u5ead\u5b9e\u9645\u4f7f\u7528\u573a\u666f\u7684\u6df1\u5ea6\u4f18\u5316\u3002<strong>\u4ee5\u4e0b\u662f\u8212\u4eab\u53cc\u98ce\u6247\u7cfb\u5217\u7684\u5173\u952e\u53d1\u5c55\u8282\u70b9\uff1a<\/strong>\n    <\/div>\n    <div style=\"flex-shrink:0;width:300px;max-width:100%\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p10-02.jpeg\" alt=\"\u8212\u4eab\u53cc\u98ce\u6247\u5ba2\u5385\u573a\u666f\" class=\"img-responsive img-shadow\" style=\"border-radius:12px\">\n      <div class=\"img-caption\">\u8212\u4eab\u53cc\u98ce\u6247 \u00b7 \u5927\u5e73\u5c42\u5ba2\u5385\u5b9e\u88c5\u53c2\u8003<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"card\">\n    <div class=\"timeline\">\n      <div class=\"tl-item\">\n        <div class=\"tl-year\">2015\u5e74<\/div>\n        <div class=\"tl-title\">\u65e5\u7acbEX\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u5e73\u53f0\u4e0a\u5e02<\/div>\n        <div class=\"tl-desc\">\u91c7\u7528\u65b0\u4e00\u4ee3\u9ad8\u6548\u6da1\u65cb\/\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u6280\u672f\uff0c\u5168\u76f4\u6d41\u53d8\u9891\u9a71\u52a8\uff0c\u5960\u5b9a\u65e5\u7acb\u5bb6\u7528\u4e2d\u592e\u7a7a\u8c03\"\u9ad8\u80fd\u6548+\u9ad8\u53ef\u9760\u6027\"\u7684\u6280\u672f\u57fa\u56e0\u3002\u540c\u5e74\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5728\u6210\u90fd\u7b49\u897f\u90e8\u57ce\u5e02\u5efa\u7acb\u6df1\u5ea6\u6e20\u9053\u4f53\u7cfb\u3002<\/div>\n      <\/div>\n      <div class=\"tl-item\">\n        <div class=\"tl-year\">2018\u5e74<\/div>\n        <div class=\"tl-title\">\u8212\u4eab\u7cfb\u5217\u9996\u4ee3\u4e0a\u5e02 \u00b7 \u5355\u98ce\u6247\u65b9\u6848<\/div>\n        <div class=\"tl-desc\">\u4e3b\u6253\u9ad8\u6027\u4ef7\u6bd4\u8def\u7ebf\uff0c\u8986\u76d680~160\u578b\uff088.0~16.0kW\uff09\uff0c\u91c7\u7528\u5355\u98ce\u6247\u7d27\u51d1\u8bbe\u8ba1\u3002\u4ee5\"\u591f\u7528\u3001\u5b9e\u60e0\u3001\u597d\u88c5\"\u5b9a\u4f4d\u8fc5\u901f\u5360\u9886\u4e2d\u7aef\u5e02\u573a\u3002\u6210\u90fd\u5730\u533a\u6210\u4e3a\u8212\u4eab\u7cfb\u5217\u6838\u5fc3\u9500\u552e\u533a\u57df\u3002<\/div>\n      <\/div>\n      <div class=\"tl-item\">\n        <div class=\"tl-year\">2021\u5e74<\/div>\n        <div class=\"tl-title\">\u4e13\u5229\u51b7\u5a92\u788e\u6ce1\u964d\u566a\u6280\u672f\u83b7\u6279<\/div>\n        <div class=\"tl-desc\">\u4e13\u5229\u53f7CN106440316B\u2014\u2014\u81ea\u7814\u51b7\u5a92\u788e\u6ce1\u964d\u566a\u88c5\u7f6e\uff0c\u4ece\u6e90\u5934\u6d88\u9664\u51b7\u5a92\u6d41\u52a8\u6c14\u6ce1\u7834\u88c2\u566a\u97f3\u3002\u5ba4\u5185\u673a\u6700\u4f4e17dB\uff0c\u4e3a\u8212\u4eab\u7cfb\u5217\u5efa\u7acb\"\u9759\u97f3\u54c1\u8d28\"\u6807\u7b7e\u3002\u540c\u671f\u667a\u80fd\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\u529f\u80fd\u4e0a\u7ebf\u3002<\/div>\n      <\/div>\n      <div class=\"tl-item gold\">\n        <div class=\"tl-year\">2023\u5e74<\/div>\n        <div class=\"tl-title\">\u8212\u4eab\u53cc\u98ce\u6247\u7248\u672c\u53d1\u5e03 \u00b7 125~160\u578b<\/div>\n        <div class=\"tl-desc\">\u5728\u5355\u98ce\u6247\u57fa\u7840\u4e0a\u5168\u9762\u5347\u7ea7\uff1a\u53cc\u98ce\u6247\u5f3a\u52b2\u6392\u98ce\uff08\u98ce\u91cf\u63d0\u5347\u81f388~101m\u00b3\/min\uff09\u3001320mm\u8584\u673a\u8eab\u30010\/30Pa\u9759\u538b\u53ef\u8c03\u3002APF\u6700\u9ad86.10\uff0c\u5236\u51b7\u8303\u56f4\u62d3\u5c55\u81f3-5~59\u2103\uff0c\u5236\u70ed-23~17\u2103\u3002\u53cc\u98ce\u6247\u6210\u4e3a\u8212\u4eab\u7cfb\u5217\u65d7\u8230\u6807\u7b7e\u3002<\/div>\n      <\/div>\n      <div class=\"tl-item highlight\">\n        <div class=\"tl-year\">2024\u5e74<\/div>\n        <div class=\"tl-title\">\u5927\u5bb9\u91cf180~224\u578b\u6269\u5c55\u53d1\u5e03<\/div>\n        <div class=\"tl-desc\">\u54cd\u5e94\u5927\u6237\u578b\u548c\u522b\u5885\u5e02\u573a\u9700\u6c42\uff0c\u63a8\u51fa180\/200\/224\u4e09\u6b3e\u5927\u5bb9\u91cf\u673a\u578b\u3002\u989d\u5b9a\u5236\u51b718.0~22.4kW\uff0c\u6700\u591a\u4e00\u62d612\u53f0\u5185\u673a\uff0c\u8986\u76d6140~200\u33a1\u5927\u7a7a\u95f4\u3002APF\u6700\u9ad85.05\uff0c\u5ef6\u7eed\u53cc\u98ce\u6247+320mm\u8584\u673a\u8eab+52\u2103\u9ad8\u6e29\u5236\u51b7\u5168\u90e8\u6838\u5fc3\u6280\u672f\u3002<\/div>\n      <\/div>\n      <div class=\"tl-item green\">\n        <div class=\"tl-year\">2025\u5e74 \u00b7 \u73b0\u5728<\/div>\n        <div class=\"tl-title\">\u8212\u4eab\u53cc\u98ce\u6247\u5168\u7cfb\u5217\u5b8c\u5584<\/div>\n        <div class=\"tl-desc\">\u5f62\u6210125~224\u578b\u5b8c\u6574\u4ea7\u54c1\u77e9\u9635\uff08\u6807\u51c6125~160\u578b + \u5927\u5bb9\u91cf180~224\u578b\uff09\uff0c\u8986\u76d680~200\u33a1\u5168\u6237\u578b\u3002\u5927\u5bb9\u91cf\u6bb5\u4ee5\"\u6027\u80fd\u591f\u7528\u3001\u4ef7\u683c\u6700\u4f18\"\u7b56\u7565\uff0c\u4e0e\u5c0a\u777f\u7cfb\u5217\u5f62\u6210\u6e05\u6670\u7684\u4ea7\u54c1\u68af\u5ea6\uff0c\u6210\u4e3a\u6210\u90fd\u5e02\u573a\u7684\"\u751c\u70b9\"\u9009\u62e9\u3002<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"insight green\">\n    <div class=\"it\">\u6280\u672f\u4f20\u627f \u00b7 \u6301\u7eed\u8fdb\u5316<\/div>\n    \u4ece2015\u5e74EX\u5e73\u53f0\u52302024\u5e74\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\uff0c\u8212\u4eab\u7cfb\u5217\u59cb\u7ec8\u56f4\u7ed5<strong>\"\u8ba9\u66f4\u591a\u5bb6\u5ead\u7528\u4e0a\u597d\u7a7a\u8c03\"<\/strong>\u7684\u521d\u5fc3\u8fed\u4ee3\u3002\u6bcf\u4e00\u6b21\u5347\u7ea7\u90fd\u805a\u7126\u4e09\u4e2a\u65b9\u5411\uff1a\u2460\u80fd\u6548\u66f4\u9ad8\uff08APF\u4ece5.0\u52306.10\uff09\u3001\u2461\u9002\u7528\u66f4\u5e7f\uff08\u4ece\u5355\u98ce\u6247\u5230\u53cc\u98ce\u6247\u3001\u4ece\u5c0f\u5bb9\u91cf\u5230\u5927\u5bb9\u91cf\uff09\u3001\u2462\u5b89\u88c5\u66f4\u53cb\u597d\uff08320mm\u8584\u673a\u8eab\u30010\/30Pa\u9759\u538b\u53ef\u8c03\uff09\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a72 \u4ea7\u54c1\u5b9a\u4f4d\u4e0e\u6838\u5fc3\u4f18\u52bf ===== -->\n<section class=\"sec\" id=\"s2\">\n  <div class=\"sh\"><div class=\"snum\">2<\/div><h2 class=\"stitle\">\u4ea7\u54c1\u5b9a\u4f4d\u4e0e\u6838\u5fc3\u4f18\u52bf<\/h2><\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\"><span class=\"ct-ico\">\ud83c\udfe0<\/span>\u9002\u7528\u573a\u666f<\/div>\n    <div style=\"display:grid;grid-template-columns:1fr 1fr;gap:12px 20px;font-size:14px;color:var(--text2);line-height:1.8\">\n      <div>\u2705 140~200\u33a1\u5927\u5e73\u5c42\/\u590d\u5f0f\/\u522b\u5885\u5168\u5c4b\u8986\u76d6<\/div>\n      <div>\u2705 \u9ad8\u6e29\u6c14\u5019\u533a\uff08\u534e\u5357\/\u897f\u5357\uff0952\u2103\u7a33\u5b9a\u5236\u51b7<\/div>\n      <div>\u2705 \u5916\u673a\u4f4d\u7eb5\u6df1\u53d7\u9650\uff08\u4ec5320mm\uff09\u7684\u5b89\u88c5\u73af\u5883<\/div>\n      <div>\u2705 \u9700\u4e00\u62d69~12\u53f0\u5185\u673a\u7684\u5927\u6237\u578b<\/div>\n      <div>\u2705 \u5bf9\u9759\u97f3\u6709\u9ad8\u8981\u6c42\u7684\u5367\u5ba4\/\u4e66\u623f\u533a\u57df<\/div>\n      <div>\u2705 \u9e3d\u5b50\u7b3c\/\u5916\u673a\u4f4d\u903c\u4ec4\u7b49\u7279\u6b8a\u5b89\u88c5\u73af\u5883<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\"><span class=\"ct-ico\">\u2b50<\/span>\u6838\u5fc3\u5356\u70b9\u901f\u89c8<\/div>\n    <table class=\"dt\">\n      <thead>\n        <tr><th style=\"width:120px\">\u5356\u70b9<\/th><th style=\"width:100px\">\u5173\u952e\u6570\u636e<\/th><th>\u6280\u672f\u63cf\u8ff0<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td class=\"label\">\u53cc\u91cd\u6563\u70ed<\/td><td class=\"hl-r\">52\u2103<\/td>\n          <td style=\"text-align:left;font-size:13px\">\u9ad8\u6548\u98ce\u51b7+\u51b7\u5a92\u51b7\u5374\u53cc\u91cd\u6563\u70ed\uff0c360\u00b0\u5168\u5305\u8986\u76d6\u8d34\u5408\u51b7\u5a92\u94dc\u7ba1\uff0c\u8fdb\u53e3\u65e0\u94c5\u9521\u5408\u91d1\u7247\u5bfc\u70ed\u57ab\u7247<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">\u8d85\u4e00\u7ea7\u80fd\u6548<\/td><td class=\"hl-g\">APF 5.05<\/td>\n          <td style=\"text-align:left;font-size:13px\">\u65b0\u4e00\u4ee3\u9ad8\u6548\u538b\u7f29\u673a+\u5168\u76f4\u6d41\u53d8\u9891\u6280\u672f\uff0c\u5747\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\u6807\u51c6<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">\u6781\u81f4\u9759\u97f3<\/td><td class=\"hl-b\">17dB(A)<\/td>\n          <td style=\"text-align:left;font-size:13px\">\u4e13\u5229\u51b7\u5a92\u788e\u6ce1\u6280\u672f\uff08CN106440316B\uff09\uff0c\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\u6700\u591a\u964d9dB<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">\u53cc\u98ce\u6247\u7d27\u51d1<\/td><td class=\"hl-y\">320mm<\/td>\n          <td style=\"text-align:left;font-size:13px\">\u53cc\u98ce\u6247\u5f3a\u52b2\u6392\u98ce+\u7d27\u51d1\u673a\u8eab\uff0c\u6700\u5c0f\u539a\u5ea6\u4ec5320mm\uff0c\u9002\u914d\u72ed\u7a84\u5916\u673a\u4f4d<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a73 \u9002\u7528\u6237\u578b\u4e0e\u9762\u79ef ===== -->\n  <div style=\"margin-bottom:18px;text-align:center\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-02.jpeg\" alt=\"\u4e2d\u592e\u7a7a\u8c03\u573a\u666f\u56fe\" class=\"img-responsive img-shadow\" style=\"border-radius:12px;max-width:700px;width:100%\">\n    <div class=\"img-caption\">\u8212\u4eab\u53cc\u98ce\u6247 \u00b7 \u5927\u5e73\u5c42\u5168\u5c4b\u8986\u76d6\u65b9\u6848\u793a\u610f<\/div>\n  <\/div>\n\n<section class=\"sec\" id=\"s3\">\n  <div class=\"sh\"><div class=\"snum\">3<\/div><h2 class=\"stitle\">\u9002\u7528\u6237\u578b\u4e0e\u9762\u79ef\u53c2\u8003<\/h2><\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\">\ud83d\udcd0 \u5916\u673a\u578b\u53f7-\u9762\u79ef-\u5185\u673a\u6570\u5bf9\u7167\u8868<\/div>\n    <table class=\"dt\">\n      <thead>\n        <tr><th>\u5916\u673a\u578b\u53f7<\/th><th>\u989d\u5b9a\u5236\u51b7\/\u5236\u70ed<\/th><th>\u9002\u7528\u9762\u79ef<\/th><th>\u6700\u591a\u5185\u673a<\/th><th>\u5178\u578b\u6237\u578b<\/th><th>APF<\/th><th>\u5907\u6ce8<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td class=\"label\">RAS-180HRNBQ<\/td>\n          <td>18.0\/20.0kW<\/td><td>140~170\u33a1<\/td><td>9\u53f0<\/td><td>\u4e09\u5ba4\u4e24\u5385+\u53a8\u536b<\/td><td class=\"hl-g\">5.05<\/td><td>\u6700\u5b89\u9759\uff0c\u5165\u95e8\u5927\u5bb9\u91cf<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">RAS-200HRNBQ<\/td>\n          <td>20.0\/22.4kW<\/td><td>160~185\u33a1<\/td><td>10\u53f0<\/td><td>\u56db\u5ba4\u4e24\u5385+\u53a8\u536b<\/td><td>5.00<\/td><td>\u4e2d\u578b\u5927\u5e73\u5c42\u9996\u9009<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">RAS-224HRNBQ<\/td>\n          <td>22.4\/25.0kW<\/td><td>180~200\u33a1<\/td><td>12\u53f0<\/td><td>\u5927\u5e73\u5c42\/\u522b\u5885<\/td><td>5.00<\/td><td>\u6700\u5927\u51b7\u91cf\uff0c\u4e00\u62d6\u5341\u4e8c<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"insight gold\">\n    <div class=\"it\">\u26a0\ufe0f \u9762\u79ef\u4f30\u7b97\u63d0\u9192<\/div>\n    \u4ee5\u4e0a\u4e3a\u53c2\u8003\u8303\u56f4\uff0c\u5b9e\u9645\u9009\u578b\u9700\u7ed3\u5408\u623f\u5c4b\u671d\u5411\u3001\u5c42\u9ad8\u3001\u4fdd\u6e29\u60c5\u51b5\u3001\u540c\u5f00\u7387\u7b49\u56e0\u7d20\u7efc\u5408\u8ba1\u7b97\u3002\u5efa\u8bae\u914d\u6bd4\u63a7\u5236\u572890%~110%\u6700\u4f18\u533a\u95f4\u3002<strong>\u4e0d\u786e\u5b9a\u5982\u4f55\u9009\uff1f<\/strong>\u62c9\u5230\u9875\u9762\u5e95\u90e8\u8054\u7cfb\u6211\u4eec\uff0c\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u5e08\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a74 \u6838\u5fc3\u6280\u672f\u53c2\u6570 ===== -->\n<section class=\"sec\" id=\"s4\">\n  <div class=\"sh\"><div class=\"snum\">4<\/div><h2 class=\"stitle\">\u6838\u5fc3\u6280\u672f\u53c2\u6570<\/h2><span class=\"stitle-sub\">180 \/ 200 \/ 224 \u578b\u5b8c\u6574\u89c4\u683c<\/span><\/div>\n\n  <button class=\"collapse-toggle open\" onclick=\"toggleCollapse(this)\">\ud83d\udcca \u5b8c\u6574\u53c2\u6570\u8868 <span class=\"ct-arrow\">\u25bc<\/span> \u6536\u8d77<\/button>\n  <div class=\"collapse-wrap\" style=\"max-height:6000px\">\n  <div style=\"display:flex;gap:24px;align-items:flex-start;flex-wrap:wrap\">\n    <div class=\"card\" style=\"flex:1;min-width:420px\">\n      <div class=\"ct\">\ud83d\udcca \u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u5916\u673a\u53c2\u6570\u4e00\u89c8<\/div>\n    <table class=\"dt\">\n      <thead>\n        <tr><th style=\"width:140px;text-align:left\">\u53c2\u6570\u9879<\/th><th style=\"background:var(--green);color:#fff\">RAS-180HRNBQ<\/th><th style=\"background:var(--blue);color:#fff\">RAS-200HRNBQ<\/th><th style=\"background:var(--gold);color:var(--dark)\">RAS-224HRNBQ<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"label\">\u989d\u5b9a\u5236\u51b7\u91cf kW<\/td><td>18.0<\/td><td>20.0<\/td><td>22.4<\/td><\/tr>\n        <tr><td class=\"label\">\u989d\u5b9a\u5236\u70ed\u91cf kW<\/td><td>20.0<\/td><td>22.4<\/td><td>25.0<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u51b7\u8f93\u5165\u529f\u7387 kW<\/td><td>5.46<\/td><td>5.85<\/td><td>6.96<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u70ed\u8f93\u5165\u529f\u7387 kW<\/td><td>5.13<\/td><td>5.61<\/td><td>6.31<\/td><\/tr>\n        <tr><td class=\"label\">APF \u5168\u5e74\u80fd\u6548\u6bd4<\/td><td class=\"hl-g\">5.05<\/td><td>5.00<\/td><td>5.00<\/td><\/tr>\n        <tr><td class=\"label\">\u80fd\u6548\u7b49\u7ea7<\/td><td class=\"hl-g\">\u8d85\u4e00\u7ea7<\/td><td class=\"hl-g\">\u8d85\u4e00\u7ea7<\/td><td class=\"hl-g\">\u8d85\u4e00\u7ea7<\/td><\/tr>\n        <tr><td class=\"label\">\u5916\u5f62\u5c3a\u5bf8 H\u00d7W\u00d7D mm<\/td><td colspan=\"3\">1380\u00d7950\u00d7320<\/td><\/tr>\n        <tr><td class=\"label\">\u51c0\u91cd kg<\/td><td>118<\/td><td>118<\/td><td>122<\/td><\/tr>\n        <tr><td class=\"label\">\u538b\u7f29\u673a\u7c7b\u578b<\/td><td colspan=\"3\">\u53d8\u9891\u53cc\u8f6c\u5b50\u5f0f\u538b\u7f29\u673a<\/td><\/tr>\n        <tr><td class=\"label\">\u566a\u97f3 \u51b7\/\u6696 dB(A)<\/td><td>56\/58<\/td><td>58\/60<\/td><td>58\/60<\/td><\/tr>\n        <tr><td class=\"label\">\u591c\u95f4\u9759\u97f3\u6a21\u5f0f dB(A)<\/td><td>48<\/td><td>50<\/td><td>50<\/td><\/tr>\n        <tr><td class=\"label\">\u98ce\u6247\u98ce\u91cf m\u00b3\/min<\/td><td>101<\/td><td>122<\/td><td>122<\/td><\/tr>\n        <tr><td class=\"label\">\u6700\u591a\u5185\u673a\u8fde\u63a5\u6570<\/td><td>9\u53f0<\/td><td>10\u53f0<\/td><td>12\u53f0<\/td><\/tr>\n        <tr><td class=\"label\">\u51b7\u5a92\u6db2\u7ba1\/\u6c14\u7ba1 mm<\/td><td colspan=\"3\">\u03a69.53 \/ \u03a619.05\uff08\u6269\u53e3\u8fde\u63a5\uff09<\/td><\/tr>\n        <tr><td class=\"label\">\u6700\u5927\u5b9e\u9645\u914d\u7ba1\u957f\u5ea6<\/td><td>75m<\/td><td>75m<\/td><td>80m<\/td><\/tr>\n        <tr><td class=\"label\">\u6700\u5927\u914d\u7ba1\u603b\u957f\u5ea6<\/td><td>120m<\/td><td>120m<\/td><td>200m<\/td><\/tr>\n        <tr><td class=\"label\">\u5ba4\u5185\u5916\u673a\u6700\u5927\u9ad8\u4f4e\u5dee<\/td><td colspan=\"3\">30m<\/td><\/tr>\n        <tr><td class=\"label\">\u5185\u673a\u95f4\u6700\u5927\u9ad8\u4f4e\u5dee<\/td><td colspan=\"3\">10m<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u51b7\u8fd0\u884c\u8303\u56f4 \u2103 DB<\/td><td colspan=\"3\">-5~52<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u70ed\u8fd0\u884c\u8303\u56f4 \u2103 DB<\/td><td colspan=\"3\">-20~23<\/td><\/tr>\n        <tr><td class=\"label\">\u9759\u538b\u53ef\u8c03<\/td><td colspan=\"3\">0\/30Pa<\/td><\/tr>\n        <tr><td class=\"label\">\u5bb9\u91cf\u914d\u6bd4\u8303\u56f4<\/td><td colspan=\"3\">50%~130%<\/td><\/tr>\n        <tr><td class=\"label\">\u6700\u5927\u7194\u4e1d\u7535\u6d41 MFA<\/td><td>40A<\/td><td>40A<\/td><td>50A<\/td><\/tr>\n        <tr><td class=\"label\">\u6700\u5c0f\u7ebf\u8def\u7535\u6d41 MCA<\/td><td>32A<\/td><td>32A<\/td><td>40A<\/td><\/tr>\n        <tr><td class=\"label\">\u5ba4\u5916\u673a\u7535\u6e90<\/td><td colspan=\"3\">220V~50Hz<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u51b7\u5242<\/td><td colspan=\"3\">R410A<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <div style=\"flex-shrink:0;width:280px;max-width:100%\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg\" alt=\"\u8212\u4eab\u53cc\u98ce\u6247\u5916\u673a\u4ea7\u54c1\u56fe\" class=\"img-responsive img-shadow\" style=\"border-radius:12px\">\n    <div class=\"img-caption\">\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u5916\u673a \u00b7 320mm\u8d85\u8584\u673a\u8eab<\/div>\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg\" alt=\"\u5927\u6237\u65b9\u6848\u5168\u666f\u793a\u610f\u56fe\" class=\"img-responsive img-shadow\" style=\"border-radius:12px;margin-top:14px\">\n    <div class=\"img-caption\">\u8212\u4eab\u53cc\u98ce\u6247224\u578b \u00b7 \u4e00\u62d612\u5927\u6237\u65b9\u6848\u793a\u610f<\/div>\n  <\/div>\n  <\/div><!-- \/.collapse-wrap -->\n<\/div><\/section>\n\n<!-- ===== \u00a74b \u7cfb\u5217\u5185\u5bf9\u6bd4 ===== -->\n<button class=\"collapse-toggle open\" onclick=\"toggleCollapse(this)\">\ud83d\udd04 \u7cfb\u5217\u5185\u5bf9\u6bd4 <span class=\"ct-arrow\">\u25bc<\/span> \u6536\u8d77<\/button>\n<div class=\"collapse-wrap\" style=\"max-height:6000px\">\n<div class=\"card\">\n  <div class=\"ct\">\ud83d\udd04 \u7cfb\u5217\u5185\u5bf9\u6bd4\uff1a\u8212\u4eab\u53cc\u98ce\u6247 vs \u8212\u4eab\u5355\u98ce\u6247 vs EX-PRO<\/div>\n  <div class=\"scope\">\n    <strong>\u540c\u4e3a\u65e5\u7acbEX-\u8212\u4eab\u7cfb\u5217\uff0c\u4e09\u6b3e\u5982\u4f55\u9009\uff1f<\/strong>\u53cc\u98ce\u6247\u5927\u5bb9\u91cf(180~224\u578b)\u3001\u5355\u98ce\u6247(80~160\u578b)\u3001EX-PRO(80~160\u578b) \u8986\u76d6\u4e0d\u540c\u6237\u578b\u4e0e\u9884\u7b97\u3002\u4ee5\u4e0b\u6309\u5bb9\u91cf\u7ea7\u522b\u540c\u53f0\u6bd4\u8f83\u3002\n  <\/div>\n\n  <table class=\"dt\">\n    <thead>\n      <tr><th style=\"width:100px;text-align:left\">\u5bf9\u6bd4\u9879<\/th>\n        <th class=\"series-h sh-g\">\u8212\u4eab\u53cc\u98ce\u6247<br>\u5927\u5bb9\u91cf180~224<\/th>\n        <th class=\"series-h sh-b\">\u8212\u4eab\u5355\u98ce\u6247<br>80~160\u578b<\/th>\n        <th class=\"series-h sh-y\">EX-PRO<br>80~160\u578b<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr><td class=\"label\">\u4ea7\u54c1\u5b9a\u4f4d<\/td><td>\u5927\u6237\u578b\u6027\u4ef7\u6bd4\u65d7\u8230<\/td><td>\u4e2d\u7aef\u6027\u4ef7\u6bd4\u9996\u9009<\/td><td>\u5165\u95e8\u7ea7\u7ecf\u6d4e\u65b9\u6848<\/td><\/tr>\n      <tr><td class=\"label\">\u5bb9\u91cf\u8303\u56f4<\/td><td class=\"hl-g\">18.0~22.4kW<\/td><td>8.0~16.0kW<\/td><td>8.0~16.0kW<\/td><\/tr>\n      <tr><td class=\"label\">\u9002\u7528\u9762\u79ef<\/td><td class=\"hl-g\">140~200\u33a1<\/td><td>80~140\u33a1<\/td><td>80~140\u33a1<\/td><\/tr>\n      <tr><td class=\"label\">\u98ce\u6247\u8bbe\u8ba1<\/td><td class=\"hl-g\">\u53cc\u98ce\u6247 \u00b7 101~122m\u00b3\/min<\/td><td>\u5355\u98ce\u6247<\/td><td>\u5355\u98ce\u6247<\/td><\/tr>\n      <tr><td class=\"label\">\u673a\u8eab\u539a\u5ea6<\/td><td class=\"hl-g\">320mm\uff08\u6700\u8584\uff09<\/td><td>320~370mm<\/td><td>320~370mm<\/td><\/tr>\n      <tr><td class=\"label\">APF\u6700\u9ad8\u503c<\/td><td>5.05<\/td><td class=\"hl-b\">6.10\uff08\u6700\u9ad8\uff09<\/td><td>5.60<\/td><\/tr>\n      <tr><td class=\"label\">\u6700\u591a\u5185\u673a\u6570<\/td><td class=\"hl-g\">9~12\u53f0<\/td><td>5~7\u53f0<\/td><td>5~7\u53f0<\/td><\/tr>\n      <tr><td class=\"label\">\u5236\u51b7\u8303\u56f4<\/td><td>-5~52\u2103<\/td><td class=\"hl-b\">-5~59\u2103<\/td><td>-5~52\u2103<\/td><\/tr>\n      <tr><td class=\"label\">\u5236\u70ed\u8303\u56f4<\/td><td>-20~23\u2103<\/td><td class=\"hl-b\">-23~17\u2103<\/td><td>-20~23\u2103<\/td><\/tr>\n      <tr><td class=\"label\">\u566a\u97f3 \u51b7\/\u6696<\/td><td>56~58 \/ 58~60<\/td><td class=\"hl-b\">50~56 \/ 52~58<\/td><td>52~58 \/ 54~60<\/td><\/tr>\n      <tr><td class=\"label\">\u9759\u538b\u53ef\u8c03<\/td><td class=\"hl-g\">0\/30Pa<\/td><td>0\/30Pa<\/td><td>\u2014<\/td><\/tr>\n      <tr><td class=\"label\">\u538b\u7f29\u673a<\/td><td colspan=\"3\" style=\"text-align:center;font-size:12px\">\u5747\u4e3a\u53d8\u9891\u53cc\u8f6c\u5b50\u5f0f\u538b\u7f29\u673a\uff08\u540c\u5e73\u53f0\u6280\u672f\uff09<\/td><\/tr>\n      <tr><td class=\"label\">\u51b7\u5a92\/\u7535\u6e90<\/td><td colspan=\"3\" style=\"text-align:center;font-size:12px\">R410A \u00b7 220V~50Hz\uff08\u4e00\u81f4\uff09<\/td><\/tr>\n      <tr><td class=\"label\">\u4ef7\u683c\u533a\u95f4<\/td><td class=\"hl-g\">\u57fa\u51c61.00~1.20<\/td><td>0.55~0.85<\/td><td class=\"hl-y\">0.45~0.70<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"insight gold\" style=\"margin-top:14px\">\n    <div class=\"it\">\ud83d\udca1 \u9009\u578b\u903b\u8f91<\/div>\n    <strong>\u6237\u578b\u51b3\u5b9a\u7cfb\u5217\uff1a<\/strong>140\u33a1\u4ee5\u4e0a\u5927\u5e73\u5c42\/\u522b\u5885 \u2192 \u53cc\u98ce\u6247\u5927\u5bb9\u91cf\uff1b80~140\u33a1 \u2192 \u5355\u98ce\u6247\u6216EX-PRO\u3002<br>\n    <strong>\u9884\u7b97\u51b3\u5b9a\u5c42\u7ea7\uff1a<\/strong>\u9884\u7b97\u5145\u8db3\u9009\u5355\u98ce\u6247\uff08APF\u6700\u9ad86.10\u3001\u566a\u97f3\u66f4\u4f4e\u3001\u8fd0\u884c\u8303\u56f4\u66f4\u5bbd\uff09\uff1b\u9884\u7b97\u7d27\u53ef\u9009EX-PRO\uff08\u6838\u5fc3\u5236\u51b7\u5236\u70ed\u4e0d\u59a5\u534f\uff0c\u533a\u522b\u5728\u9644\u52a0\u529f\u80fd\uff09\u3002<br>\n    <strong>\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u5b9a\u4f4d\u6e05\u6670\uff1a<\/strong>\u5927\u6237\u578b\u9009\u62e9\uff0c\u6027\u80fd\u5168\u9762\uff0c\u4ef7\u683c\u5408\u7406\uff0c\u662f\u5927\u7a7a\u95f4\u7528\u6237\u7684\"\u4e00\u6b65\u5230\u4f4d\"\u65b9\u6848\u3002\n  <\/div>\n<\/div>\n  <\/div><!-- \/.collapse-wrap -->\n\n<!-- ===== \u00a75 \u516d\u5927\u6838\u5fc3\u6280\u672f ===== -->\n<section class=\"sec\" id=\"s5\">\n  <div class=\"sh\"><div class=\"snum\">5<\/div><h2 class=\"stitle\">\u516d\u5927\u6838\u5fc3\u6280\u672f\u6df1\u5ea6\u89e3\u8bfb<\/h2><\/div>\n\n  <div class=\"tech-grid\">\n    <div class=\"tech-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-08.jpeg\" alt=\"\u53cc\u91cd\u6563\u70ed\u6280\u672f\" class=\"img-responsive\" style=\"margin-bottom:14px;border-radius:6px\">\n      <div class=\"tc-icon\">\ud83d\udd25<\/div>\n      <div class=\"tc-title\">\u53cc\u91cd\u6563\u70ed \u00b7 52\u2103\u6781\u9650\u5236\u51b7<\/div>\n      <div class=\"tc-desc\">\n        \u9ad8\u6548\u98ce\u51b7+\u51b7\u5a92\u51b7\u5374\u53cc\u91cd\u6563\u70ed\u7cfb\u7edf\uff0c360\u00b0\u5168\u5305\u8986\u76d6\u8d34\u5408\u51b7\u5a92\u94dc\u7ba1\u3002\u91c7\u7528\u8fdb\u53e3\u65e0\u94c5\u9521\u5408\u91d1\u7247\u5bfc\u70ed\u57ab\u7247\uff0c\u5bfc\u70ed\u6548\u7387\u63d0\u534740%\u3002\u572852\u2103\u6781\u7aef\u9ad8\u6e29\u73af\u5883\u4e0b\u4ecd\u53ef\u6b63\u5e38\u5236\u51b7\uff0c\u897f\u5357\/\u534e\u5357\u9ad8\u6e29\u5730\u533a\u65e0\u5fe7\u4f7f\u7528\u3002\n      <\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p06-01.jpeg\" alt=\"\u65b0\u4e00\u4ee3\u538b\u7f29\u673a\u6280\u672f\" class=\"img-responsive\" style=\"margin-bottom:14px;border-radius:6px\">\n      <div class=\"tc-icon\">\u26a1<\/div>\n      <div class=\"tc-title\">\u6f8e\u6e43\u82af\u52a8\u529b \u00b7 \u65b0\u4e00\u4ee3\u538b\u7f29\u673a<\/div>\n      <div class=\"tc-desc\">\n        \u65b0\u4e00\u4ee3\u9ad8\u6548\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff1a\u591a\u652f\u6491\u8f74\u7cfb\u7a33\u5b9a\u7ed3\u6784\u3001\u5c0f\u578b\u5316\u9ad8\u8f6c\u77e9\u5bc6\u5ea6\u7535\u673a\u6280\u672f\u3001\u591a\u91cd\u6da6\u6ed1\u56de\u6cb9\u8bbe\u8ba1\u3002\u914d\u5408\u5168\u76f4\u6d41\u53d8\u9891\u6280\u672f\uff0c\u80fd\u6548\u5927\u5e45\u63d0\u5347\uff0cAPF\u6700\u9ad85.05\uff0c\u8fdc\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\u6807\u51c6\u3002\n      <\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p08-06.jpeg\" alt=\"\u51b7\u5a92\u788e\u6ce1\u964d\u566a\u6280\u672f\" class=\"img-responsive\" style=\"margin-bottom:14px;border-radius:6px\">\n      <div class=\"tc-icon\">\ud83d\udd07<\/div>\n      <div class=\"tc-title\">\u4e13\u5229\u51b7\u5a92\u788e\u6ce1 \u00b7 17dB\u6781\u81f4\u9759\u97f3<\/div>\n      <div class=\"tc-desc\">\n        \u4e13\u5229\u53f7CN106440316B\u2014\u2014\u81ea\u7814\u51b7\u5a92\u788e\u6ce1\u964d\u566a\u88c5\u7f6e\uff0c\u4ece\u6e90\u5934\u6d88\u9664\u51b7\u5a92\u6d41\u52a8\u6c14\u6ce1\u7834\u88c2\u4ea7\u751f\u7684\"\u5495\u565c\"\u566a\u97f3\u3002\u4e09\u5927\u566a\u97f3\u4f18\u5316\u6280\u672f\u534f\u540c\uff0c\u5ba4\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f3\u4ec517dB(A)\u3002\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\u53ef\u518d\u964d9dB\u3002\n      <\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p12-03.jpeg\" alt=\"\u65e0\u7ea7\u53d8\u9891\u7cbe\u786e\u6e29\u63a7\" class=\"img-responsive\" style=\"margin-bottom:14px;border-radius:6px\">\n      <div class=\"tc-icon\">\ud83d\udd04<\/div>\n      <div class=\"tc-title\">\u65e0\u7ea7\u53d8\u9891 \u00b7 \u7cbe\u786e\u6e29\u63a7<\/div>\n      <div class=\"tc-desc\">\n        \u667a\u80fdCS\u53d8\u9891\u5668\u642d\u914dPAM\u3001PWM\u3001\u529f\u7387\u56e0\u6570\u4fee\u6b63\u7ec4\u5408\u63a7\u5236\u6280\u672f\u3002\u538b\u7f29\u673a\u9891\u7387\u4ece0Hz\u5230480Hz\u8fde\u7eed\u7cbe\u786e\u8c03\u8282\uff0c\u5b9e\u73b0\u00b10.5\u2103\u7cbe\u786e\u63a7\u6e29\uff0c\u544a\u522b\u5ffd\u51b7\u5ffd\u70ed\u3002\u90e8\u5206\u8d1f\u8377\u5de5\u51b5\u80fd\u6548\u4f18\u5316\uff0c\u66f4\u7701\u7535\u3002\n      <\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-19.jpeg\" alt=\"0\/30Pa\u9759\u538b\u53ef\u8c03\" class=\"img-responsive\" style=\"margin-bottom:14px;border-radius:6px\">\n      <div class=\"tc-icon\">\ud83d\udcd0<\/div>\n      <div class=\"tc-title\">0\/30Pa\u9759\u538b\u53ef\u8c03 \u00b7 \u5b89\u88c5\u7075\u6d3b<\/div>\n      <div class=\"tc-desc\">\n        \u8d34\u5fc3\u8bbe\u7f6e0\/30Pa\u4e24\u6863\u9759\u538b\u53ef\u9009\uff0c\u6392\u98ce\u8ddd\u79bb\u66f4\u8fdc\u3002320mm\u8d85\u8584\u673a\u8eab\uff0c\u8f7b\u677e\u5e94\u5bf9\u9e3d\u5b50\u7b3c\u3001\u5916\u673a\u4f4d\u903c\u4ec4\u7b49\u7279\u6b8a\u5b89\u88c5\u73af\u5883\u3002\u65e0\u9700\u6539\u9020\u5efa\u7b51\u7ed3\u6784\uff0c\u964d\u4f4e\u5b89\u88c5\u96be\u5ea6\u548c\u6210\u672c\u3002\n      <\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p14-02.jpeg\" alt=\"\u4e13\u5229\u81ea\u6e05\u6d01\u9ad8\u6e29\u9664\u83cc\" class=\"img-responsive\" style=\"margin-bottom:14px;border-radius:6px\">\n      <div class=\"tc-icon\">\ud83c\udf3f<\/div>\n      <div class=\"tc-title\">\u667a\u80fd\u53cc\u51c0\u5316 \u00b7 \u547c\u5438\u5065\u5eb7<\/div>\n      <div class=\"tc-desc\">\n        \u667a\u80fd\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\u53cc\u7ba1\u9f50\u4e0b\u3002\u53ef\u9009\u914d<a href=\"?page_id=2512\" style=\"color:var(--blue);font-weight:700\">PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/a>\u2014\u2014\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0cSGS\u00d7\u5317\u91cc\u7814\u7a76\u6240\u53cc\u91cd\u8ba4\u8bc1\uff0c\u9664PM2.5 99%\u3001\u9664\u7532\u919b88.6%\u3001H3N2\u75c5\u6bd2\u706d\u6d3b\u738799.91%\u3002<br><br>\n        <em style=\"color:var(--text3);font-size:12px\">\u203b PE\u6a21\u5757\u4e3a\u9009\u914d\u51c0\u5316\u7ec4\u4ef6\uff0c\u975e\u5916\u673a\u6807\u914d\u529f\u80fd\uff0c\u9700\u53e6\u884c\u9009\u8d2d\u5e76\u5728\u5ba4\u5185\u673a\u4e0a\u5b89\u88c5\u3002<\/em>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a76 \u8212\u4eab\u53cc\u98ce\u6247 vs \u5c0a\u777f\u5168\u6548 \u5bf9\u6bd4\u5206\u6790 ===== -->\n<section class=\"sec\" id=\"s6\">\n  <div class=\"sh\"><div class=\"snum\">6<\/div><h2 class=\"stitle\">\u8212\u4eab\u53cc\u98ce\u6247 vs \u5c0a\u777f\u5168\u6548\u2161 \u00b7 \u5927\u5bb9\u91cf\u5bf9\u6bd4\u5206\u6790<\/h2><\/div>\n\n  <button class=\"collapse-toggle open\" onclick=\"toggleCollapse(this)\">\ud83d\udcca \u5b8c\u6574\u5bf9\u6bd4\u5206\u6790 <span class=\"ct-arrow\">\u25bc<\/span> \u6536\u8d77<\/button>\n  <div class=\"collapse-wrap\" style=\"max-height:15000px\">\n  <div class=\"scope\">\n    <strong>\u5bf9\u6bd4\u8303\u56f4\uff1a<\/strong>\u8212\u4eab\u53cc\u98ce\u6247 180\/200\/224 \u578b vs \u5c0a\u777f\u5168\u6548\u2161 180\/200\/224 \u578b<br>\n    <strong>\u5236\u51b7\u91cf\u5b8c\u5168\u4e00\u81f4\uff1a<\/strong>\u4e09\u7ec4\u5bf9\u6bd4\u5236\u51b7\u91cf\u5747\u4e3a18.0\/20.0\/22.4kW\uff0c\u5dee\u5f02\u5728\u538b\u7f29\u673a\u6280\u672f\u3001APF\u3001\u8fd0\u884c\u8303\u56f4\u7b49\u6838\u5fc3\u7ef4\u5ea6\u3002\n  <\/div>\n\n  <div class=\"card\" style=\"padding:20px 30px\">\n    <div style=\"display:flex;gap:24px;align-items:center;text-align:center;flex-wrap:wrap\">\n      <div style=\"flex:1;min-width:200px\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg\" alt=\"\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u5916\u673a\" class=\"img-responsive img-shadow\" style=\"border-radius:12px\">\n        <div style=\"margin-top:10px;font-size:14px;font-weight:700;color:var(--green)\">\u8212\u4eab\u53cc\u98ce\u6247 \u5927\u5bb9\u91cf<\/div>\n        <div style=\"font-size:12px;color:var(--text3)\">\u53cc\u8f6c\u5b50\u538b\u7f29\u673a \u00b7 \u8d85\u4e00\u7ea7\u80fd\u6548<\/div>\n      <\/div>\n      <div style=\"flex-shrink:0\">\n        <div style=\"width:60px;height:60px;border-radius:50%;background:var(--brand-red);color:#fff;display:flex;align-items:center;justify-content:center;font-size:22px;font-weight:800\">VS<\/div>\n      <\/div>\n      <div style=\"flex:1;min-width:200px\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM\u5c0a\u777f\u5168\u6548-II02.jpg\" alt=\"\u5c0a\u777f\u5168\u6548\u5916\u673a\" class=\"img-responsive img-shadow\" style=\"border-radius:12px\">\n        <div style=\"margin-top:10px;font-size:14px;font-weight:700;color:#8b6914\">\u5c0a\u777f\u5168\u6548\u2161<\/div>\n        <div style=\"font-size:12px;color:var(--text3)\">\u8865\u6c14\u589e\u7113\u6da1\u65cb \u00b7 \u6e29\u6e7f\u53cc\u63a7<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- 180+200 \u8054\u5408\u5bf9\u6bd4\u8868 -->\n  <div class=\"card\">\n    <div class=\"ct\">\ud83d\udcca 180 \/ 200 \u578b\u5168\u53c2\u6570\u5bf9\u7167\u8868<\/div>\n    <table class=\"dt\">\n      <thead>\n        <tr><th style=\"width:90px;text-align:left\">\u5bf9\u6bd4\u9879<\/th>\n          <th colspan=\"2\" class=\"series-h sh-g\">\u8212\u4eab 180<\/th>\n          <th colspan=\"2\" class=\"series-h sh-y\">\u5c0a\u777f 180<\/th>\n          <th colspan=\"2\" class=\"series-h sh-g\">\u8212\u4eab 200<\/th>\n          <th colspan=\"2\" class=\"series-h sh-y\">\u5c0a\u777f 200<\/th>\n        <\/tr>\n        <tr><th><\/th><th>\u8212\u4eab<\/th><th>\u5dee<\/th><th>\u5c0a\u777f<\/th><th>\u5dee<\/th><th>\u8212\u4eab<\/th><th>\u5dee<\/th><th>\u5c0a\u777f<\/th><th>\u5dee<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"label\">\u5236\u51b7\u91cf kW<\/td><td>18.0<\/td><td><\/td><td>18.0<\/td><td><\/td><td>20.0<\/td><td><\/td><td>20.0<\/td><td><\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u70ed\u91cf kW<\/td><td>20.0<\/td><td><\/td><td>20.0<\/td><td><\/td><td>22.4<\/td><td><\/td><td>22.4<\/td><td><\/td><\/tr>\n        <tr><td class=\"label\">APF<\/td><td class=\"hl-g\">5.05<\/td><td><\/td><td class=\"hl-y\">5.55<\/td><td class=\"diff up\">+10%<\/td><td class=\"hl-g\">5.00<\/td><td><\/td><td class=\"hl-y\">5.45<\/td><td class=\"diff up\">+9%<\/td><\/tr>\n        <tr><td class=\"label\">\u566a\u97f3 \u51b7\/\u6696<\/td><td>56\/58<\/td><td><\/td><td class=\"hl-y\">54\/56<\/td><td class=\"diff down\">-2dB<\/td><td>58\/60<\/td><td><\/td><td class=\"hl-y\">55\/57<\/td><td class=\"diff down\">-3dB<\/td><\/tr>\n        <tr><td class=\"label\">\u538b\u7f29\u673a<\/td><td>\u53cc\u8f6c\u5b50<\/td><td><\/td><td class=\"hl-y\">\u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td class=\"diff up\">\u2191<\/td><td>\u53cc\u8f6c\u5b50<\/td><td><\/td><td class=\"hl-y\">\u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td class=\"diff up\">\u2191<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u51b7\u8303\u56f4<\/td><td>-5~52\u2103<\/td><td><\/td><td class=\"hl-y\">-5~60\u2103<\/td><td class=\"diff up\">+8\u2103<\/td><td>-5~52\u2103<\/td><td><\/td><td class=\"hl-y\">-5~60\u2103<\/td><td class=\"diff up\">+8\u2103<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u70ed\u8303\u56f4<\/td><td>-20~23\u2103<\/td><td><\/td><td class=\"hl-y\">-25~23\u2103<\/td><td class=\"diff down\">-5\u2103<\/td><td>-20~23\u2103<\/td><td><\/td><td class=\"hl-y\">-25~23\u2103<\/td><td class=\"diff down\">-5\u2103<\/td><\/tr>\n        <tr><td class=\"label\">\u5c3a\u5bf8 mm<\/td><td>1380\u00d7950\u00d7320<\/td><td><\/td><td>1380\u00d7950\u00d7370<\/td><td style=\"color:var(--text3)\">+50\u6df1<\/td><td>1380\u00d7950\u00d7320<\/td><td><\/td><td>1380\u00d7950\u00d7370<\/td><td style=\"color:var(--text3)\">+50\u6df1<\/td><\/tr>\n        <tr><td class=\"label\">\u4ef7\u683c\u6bd4\u4f8b<\/td><td class=\"hl-g\">1.00<\/td><td><\/td><td class=\"hl-y\">1.17<\/td><td class=\"diff up\">+17%<\/td><td class=\"hl-g\">1.03<\/td><td><\/td><td class=\"hl-y\">1.25<\/td><td class=\"diff up\">+21%<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 224 \u5355\u72ec\u8868 -->\n  <div class=\"card\">\n    <div class=\"ct\">\ud83d\udcca 224 \u578b\u5bf9\u7167\uff08\u6700\u5927\u5bb9\u91cf\uff09<\/div>\n    <table class=\"dt\">\n      <thead>\n        <tr><th style=\"width:110px;text-align:left\">\u5bf9\u6bd4\u9879<\/th>\n          <th class=\"series-h sh-g\">\u8212\u4eab 224<\/th>\n          <th class=\"series-h sh-y\">\u5c0a\u777f 224<\/th>\n          <th>\u5dee\u5f02<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"label\">\u5236\u51b7\u91cf kW<\/td><td>22.4<\/td><td>22.4<\/td><td>\u4e00\u81f4<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u70ed\u91cf kW<\/td><td>25.0<\/td><td>25.0<\/td><td>\u4e00\u81f4<\/td><\/tr>\n        <tr><td class=\"label\">APF<\/td><td class=\"hl-g\">5.00<\/td><td class=\"hl-y\">5.35<\/td><td class=\"diff up\">+7%<\/td><\/tr>\n        <tr><td class=\"label\">\u566a\u97f3 \u51b7\/\u6696<\/td><td>58\/60<\/td><td class=\"hl-y\">56\/58<\/td><td class=\"diff down\">-2dB<\/td><\/tr>\n        <tr><td class=\"label\">\u538b\u7f29\u673a<\/td><td>\u53cc\u8f6c\u5b50<\/td><td class=\"hl-y\">\u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td class=\"diff up\">\u2191<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u51b7\u8303\u56f4<\/td><td>-5~52\u2103<\/td><td class=\"hl-y\">-5~60\u2103<\/td><td class=\"diff up\">+8\u2103<\/td><\/tr>\n        <tr><td class=\"label\">\u5236\u70ed\u8303\u56f4<\/td><td>-20~23\u2103<\/td><td class=\"hl-y\">-25~23\u2103<\/td><td class=\"diff down\">-5\u2103<\/td><\/tr>\n        <tr><td class=\"label\">\u5c3a\u5bf8 mm<\/td><td>1380\u00d7950\u00d7320<\/td><td>1380\u00d7950\u00d7370<\/td><td style=\"color:var(--text3)\">+50\u6df1<\/td><\/tr>\n        <tr><td class=\"label\">\u4ef7\u683c\u6bd4\u4f8b<\/td><td class=\"hl-g\">1.20<\/td><td class=\"hl-y\">1.42<\/td><td class=\"diff up\">+18%<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"insight blue\">\n    <div class=\"it\">\ud83d\udccc \u540c\u7ea7\u5bf9\u7167\u6838\u5fc3\u53d1\u73b0<\/div>\n    <strong>\u5236\u51b7\/\u5236\u70ed\u91cf\u5b8c\u5168\u4e00\u81f4<\/strong>\u2014\u2014\u4e09\u7ec4\u5bf9\u6bd4\u7684\u51b7\u70ed\u8f93\u51fa\u80fd\u529b\u4e00\u6a21\u4e00\u6837\uff0c\u5dee\u5f02\u96c6\u4e2d\u5728\uff1a<br>\n    \u2460 <strong>\u538b\u7f29\u673a\u6280\u672f\uff1a<\/strong>\u8212\u4eab=\u53cc\u8f6c\u5b50\uff0c\u5c0a\u777f=\u8865\u6c14\u589e\u7113\u6da1\u65cb\uff08\u6781\u7aef\u5de5\u51b5\u66f4\u5f3a\uff09<br>\n    \u2461 <strong>APF\u80fd\u6548\uff1a<\/strong>\u5c0a\u777f\u9ad87%~10%\uff08\u5168\u5e74\u7535\u8d39\u5dee\u5f02\u8f83\u5c0f\uff0c\u7ea6200~400\u5143\/\u5e74\uff09<br>\n    \u2462 <strong>\u8fd0\u884c\u8303\u56f4\uff1a<\/strong>\u5c0a\u777f\u5236\u51b7+8\u2103\uff0860\u2103 vs 52\u2103\uff09\u3001\u5236\u70ed-5\u2103\uff08-25\u2103 vs -20\u2103\uff09<br>\n    \u2463 <strong>\u566a\u97f3\uff1a<\/strong>\u5c0a\u777f\u4f4e2~3dB<br>\n    \u2464 <strong>\u4ef7\u683c\uff1a<\/strong>\u5c0a\u777f\u8d3517%~21%\n  <\/div>\n\n  <!-- \u4ef7\u683c\u6bd4\u4f8b -->\n  <div class=\"card\">\n    <div class=\"ct\">\ud83d\udcc8 \u53cc\u98ce\u6247\u7cfb\u5217\u4ef7\u683c\u6bd4\u4f8b\uff08\u57fa\u51c6=\u8212\u4eab180\u578b=1.00\uff09<\/div>\n\n    <div style=\"margin-bottom:20px\">\n      <div style=\"font-size:14px;font-weight:700;color:var(--dark);margin-bottom:10px\">180\u578b<\/div>\n      <div class=\"ratio-bar\"><span class=\"rb-val green\">1.00<\/span><div class=\"rb-track\"><div class=\"rb-fill green\" style=\"width:48%\">\u8212\u4eab\u53cc\u98ce\u6247<\/div><\/div><\/div>\n      <div class=\"ratio-bar\"><span class=\"rb-val gold\">1.17<\/span><div class=\"rb-track\"><div class=\"rb-fill gold\" style=\"width:56%\">\u5c0a\u777f\u5168\u6548\u2161<\/div><\/div><\/div>\n      <div style=\"font-size:12px;color:var(--brand-red);margin-top:3px;padding-left:44px\">\u6ea2\u4ef7 +17%<\/div>\n    <\/div>\n    <div style=\"margin-bottom:20px\">\n      <div style=\"font-size:14px;font-weight:700;color:var(--dark);margin-bottom:10px\">200\u578b<\/div>\n      <div class=\"ratio-bar\"><span class=\"rb-val green\">1.03<\/span><div class=\"rb-track\"><div class=\"rb-fill green\" style=\"width:50%\">\u8212\u4eab\u53cc\u98ce\u6247<\/div><\/div><\/div>\n      <div class=\"ratio-bar\"><span class=\"rb-val gold\">1.25<\/span><div class=\"rb-track\"><div class=\"rb-fill gold\" style=\"width:60%\">\u5c0a\u777f\u5168\u6548\u2161<\/div><\/div><\/div>\n      <div style=\"font-size:12px;color:var(--brand-red);margin-top:3px;padding-left:44px\">\u6ea2\u4ef7 +21%<\/div>\n    <\/div>\n    <div>\n      <div style=\"font-size:14px;font-weight:700;color:var(--dark);margin-bottom:10px\">224\u578b<\/div>\n      <div class=\"ratio-bar\"><span class=\"rb-val green\">1.20<\/span><div class=\"rb-track\"><div class=\"rb-fill green\" style=\"width:58%\">\u8212\u4eab\u53cc\u98ce\u6247<\/div><\/div><\/div>\n      <div class=\"ratio-bar\"><span class=\"rb-val gold\">1.42<\/span><div class=\"rb-track\"><div class=\"rb-fill gold\" style=\"width:69%\">\u5c0a\u777f\u5168\u6548\u2161<\/div><\/div><\/div>\n      <div style=\"font-size:12px;color:var(--brand-red);margin-top:3px;padding-left:44px\">\u6ea2\u4ef7 +18%<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"insight gold\">\n    <div class=\"it\">\ud83d\udca1 \u6ea2\u4ef7\u89c4\u5f8b \u00b7 \u5927\u5bb9\u91cf\u6bb5\u66f4\u503c\u5f97<\/div>\n    <strong>\u5927\u5bb9\u91cf\u6bb5\u6ea2\u4ef7\u6536\u7a84\uff1a<\/strong>\u5c0a\u777f\u5168\u6548\u2161\u5728\u5c0f\u5bb9\u91cf\u673a\u578b\uff08125\/140\u578b\uff09\u4e0a\u6ea2\u4ef7\u7ea626%\uff0c\u800c\u5728\u5927\u5bb9\u91cf180\/200\/224\u578b\u4e0a\u6ea2\u4ef7\u4ec5\u4e3a17%~21%\u3002<br><br>\n    \u8fd9\u610f\u5473\u7740\uff1a<strong>\u5927\u5bb9\u91cf\u6bb5\u4e70\u5c0a\u777f\u5168\u6548\uff0c\u591a\u82b1\u7684\u94b1\u5360\u6bd4\u4f8b\u66f4\u5c0f\uff0c\u83b7\u5f97\u7684\u5347\u7ea7\uff08\u8865\u6c14\u589e\u7113+APF+\u8fd0\u884c\u8303\u56f4\uff09\u6bd4\u4f8b\u53cd\u800c\u66f4\u5927<\/strong>\u2014\u2014\u5927\u5bb9\u91cf\u662f\u5c0a\u777f\u5168\u6548\u7684\"\u66f4\u503c\u5f97\u533a\u95f4\"\u3002\n  <\/div>\n\n  <!-- \u8212\u4eab\u5185\u90e8\u68af\u5ea6 -->\n  <div class=\"gradient-card\">\n    <div class=\"gc-title\">\ud83d\udd04 \u8212\u4eab\u53cc\u98ce\u6247 180 \u2192 200 \u2192 224 \u5347\u7ea7\u68af\u5ea6<\/div>\n    <div class=\"gc-row\">\n      <span style=\"font-weight:700;color:var(--green)\">180\u578b<\/span>\n      <span style=\"font-size:13px;color:var(--text3)\">\u57fa\u51c6<\/span>\n      <span class=\"gc-arrow\">\u2192<\/span>\n      <span style=\"font-weight:700;color:var(--blue)\">200\u578b<\/span>\n      <span style=\"font-size:13px;color:var(--text3)\">+<\/span>\n      <span class=\"gc-val\">+3.5%<\/span>\n      <span style=\"font-size:13px;color:var(--text3)\">\uff08\u4ec5\u591a\u7ea6700\u5143\uff09<\/span>\n    <\/div>\n    <div class=\"gc-row\">\n      <span style=\"font-weight:700;color:var(--blue)\">200\u578b<\/span>\n      <span style=\"font-size:13px;color:var(--text3)\">\u57fa\u51c6<\/span>\n      <span class=\"gc-arrow\">\u2192<\/span>\n      <span style=\"font-weight:700;color:var(--gold)\">224\u578b<\/span>\n      <span style=\"font-size:13px;color:var(--text3)\">+<\/span>\n      <span class=\"gc-val\">+20.1%<\/span>\n      <span style=\"font-size:13px;color:var(--text3)\">\uff08\u591a\u7ea64,062\u5143\uff09<\/span>\n    <\/div>\n    <div class=\"gc-note\">\n      200\u578b\u76f8\u6bd4180\u578b\u4ec5\u8d353.5%\uff0c\u662f\u4e09\u6b3e\u4e2d\u589e\u91cf\u6295\u5165\u6700\u4f4e\u7684\u9009\u578b\u2014\u2014\u5236\u51b7\u91cf\u4ece18.0kW\u63d0\u5347\u81f320.0kW\uff0c\u82b1\u6700\u5c0f\u7684\u94b1\u83b7\u5f97\u660e\u663e\u7684\u6027\u80fd\u63d0\u5347\u3002\u9884\u7b97\u63a5\u8fd1\u7684\u60c5\u51b5\u4e0b\uff0c<strong style=\"color:var(--green)\">\u63a8\u8350\u4f18\u5148\u8003\u8651200\u578b<\/strong>\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u6027\u80fd\u5dee\u5f02\u5b9e\u8d28\u89e3\u8bfb -->\n  <div class=\"card\">\n    <div class=\"ct\">\ud83d\udd2c \u591a\u82b117%~21%\uff0c\u4f60\u989d\u5916\u5f97\u5230\u4ec0\u4e48\uff1f<\/div>\n\n    <div style=\"margin-bottom:18px\">\n      <div style=\"font-size:15px;font-weight:700;color:var(--dark);margin-bottom:10px\">\u5347\u7ea71\uff1a\u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a<\/div>\n      <div style=\"font-size:14px;color:var(--text2);line-height:1.8;padding-left:18px\">\n        \u8212\u4eab=\u53d8\u9891\u53cc\u8f6c\u5b50\uff0c\u5c0a\u777f=\u8865\u6c14\u589e\u7113\u6da1\u65cb\u3002\u5dee\u5f02\u5728\u54ea\uff1f<br>\n        <strong style=\"color:var(--brand-red)\">\u8865\u6c14\u589e\u7113<\/strong>=\u5728\u538b\u7f29\u673a\u4e2d\u95f4\u8865\u5165\u51b7\u5a92\u84b8\u6c7d\uff0c\u589e\u5927\u5236\u70ed\u91cf\u3002\u6548\u679c\uff1a-20\u2103\u4ee5\u4e0b\u4ecd\u80fd\u5f3a\u52b2\u5236\u70ed\uff0c\u666e\u901a\u53cc\u8f6c\u5b50\u5728\u8fd9\u4e2a\u6e29\u5ea6\u6bb5\u5236\u70ed\u8870\u51cf\u4e25\u91cd\u3002<br>\n        <strong style=\"color:var(--dark)\">\u6210\u90fd\u5b9e\u9645\uff1a<\/strong>\u51ac\u5b63-5~5\u2103\uff0c\u8212\u4eab\u53cc\u8f6c\u5b50-20\u2103\u5236\u70ed\u5b8c\u5168\u591f\u7528\uff1b\u5982\u679c\u5730\u6696\u6216\u6781\u5bd2\u5730\u533a\uff0c\u8865\u6c14\u589e\u7113\u4f18\u52bf\u624d\u660e\u663e\u3002\n      <\/div>\n    <\/div>\n\n    <div style=\"margin-bottom:18px\">\n      <div style=\"font-size:15px;font-weight:700;color:var(--dark);margin-bottom:10px\">\u5347\u7ea72\uff1a\u8fd0\u884c\u8303\u56f4\u62d3\u5bbd<\/div>\n      <div style=\"font-size:14px;color:var(--text2);line-height:1.8;padding-left:18px\">\n        \u5236\u51b752\u2103\u219260\u2103\uff08+8\u2103\uff09\uff0c\u5236\u70ed-20\u2103\u2192-25\u2103\uff08-5\u2103\uff09\u3002<br>\n        <strong style=\"color:var(--dark)\">60\u2103\u5236\u51b7\uff1a<\/strong>\u6781\u7aef\u9ad8\u6e29\u5730\u533a\u6709\u5b9e\u9645\u610f\u4e49\uff0c\u6210\u90fd\u590f\u5b63\u6700\u9ad840\u2103\u5de6\u53f3\uff0c52\u2103\u4e0a\u9650\u8db3\u591f\u3002<br>\n        <strong style=\"color:var(--dark)\">-25\u2103\u5236\u70ed\uff1a<\/strong>\u9ad8\u6d77\u62d4\u6216\u5317\u65b9\u6781\u5bd2\u5730\u533a\u6709\u7528\uff0c\u6210\u90fd\u5e73\u539f\u4e0d\u9700\u8981\u3002\n      <\/div>\n    <\/div>\n\n    <div style=\"margin-bottom:18px\">\n      <div style=\"font-size:15px;font-weight:700;color:var(--dark);margin-bottom:10px\">\u5347\u7ea73\uff1aAPF\u63d0\u53477%~10%<\/div>\n      <div style=\"font-size:14px;color:var(--text2);line-height:1.8;padding-left:18px\">\n        \u4ee5180\u578b\u4e3a\u4f8b\uff0cAPF 5.55 vs 5.05\uff0c\u5dee0.5\u3002\u6362\u7b97\u5168\u5e74\u7535\u8d39\uff1a\u5047\u8bbe\u5e74\u8fd0\u884c2000\u5c0f\u65f6\u3001\u5e73\u5747\u8d1f\u83775kW\uff0cAPF\u6bcf\u63d0\u53470.5\u7ea6\u8282\u7701\u7535\u8d39<strong>200~400\u5143\/\u5e74<\/strong>\u3002<br>\n        <strong style=\"color:var(--brand-red)\">\u6ce8\u610f\uff1a<\/strong>APF\u662f\u7279\u5b9a\u5de5\u51b5\u6d4b\u8bd5\u503c\uff0c\u5b9e\u9645\u4f7f\u7528\u56e0\u542f\u505c\u3001\u90e8\u5206\u8d1f\u8377\u7b49\u56e0\u7d20\uff0c\u5dee\u5f02\u66f4\u5c0f\u3002\n      <\/div>\n    <\/div>\n\n    <div>\n      <div style=\"font-size:15px;font-weight:700;color:var(--dark);margin-bottom:10px\">\u5347\u7ea74\uff1a\u566a\u97f3\u964d\u4f4e2~3dB<\/div>\n      <div style=\"font-size:14px;color:var(--text2);line-height:1.8;padding-left:18px\">\n        \u4eba\u8033\u5bf93dB\u5dee\u5f02\u53ef\u611f\u77e5\uff0c\u4f46\u4e0d\u7b97\u663e\u8457\u3002\u5bf9\u591c\u95f4\u7761\u7720\u573a\u666f\uff0c\u66f4\u4f4e\u566a\u97f3\u662f\u52a0\u5206\u9879\uff0c\u4f46\u8212\u4eab52dB\u672c\u8eab\u5df2\u5c5e\u5b89\u9759\u6c34\u5e73\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"insight blue\">\n    <div class=\"it\">\ud83c\udfaf \u4e00\u53e5\u8bdd\u7ed3\u8bba<\/div>\n    <div style=\"display:flex;gap:20px;align-items:flex-start;flex-wrap:wrap\">\n      <div style=\"flex:1;min-width:300px\">\n        <strong>\u6210\u90fd\u5e38\u89c4\u6c14\u5019+\u540c\u5f00\u7387\u4f4e\uff1a<\/strong>\u8212\u4eab\u53cc\u98ce\u6247\u6027\u80fd\u5b8c\u5168\u591f\u7528\uff0c\u591a\u82b117%~21%\u4e70\u7684\u8865\u6c14\u589e\u7113\u548c\u8fd0\u884c\u8303\u56f4\u62d3\u5c55\uff0c\u5728\u6210\u90fd\u65e5\u5e38\u4f7f\u7528\u4e2d\u51e0\u4e4e\u7528\u4e0d\u4e0a\u2014\u2014<strong>\u4e0d\u662f\u6027\u80fd\u4e0d\u591f\uff0c\u662f\u9700\u6c42\u5339\u914d<\/strong>\u3002<br><br>\n        <strong>\u6781\u7aef\u6c14\u5019+\u540c\u5f00\u7387\u9ad8+\u7cfb\u7edf\u6269\u5c55\u9700\u6c42\uff1a<\/strong>\u5c0a\u777f\u5168\u6548\u2161\u7684\u8865\u6c14\u589e\u7113\u3001\u6e29\u6e7f\u53cc\u63a7\u3001\u6c34\u6a21\u5757\u6269\u5c55\u662f\u5b9e\u5b9e\u5728\u5728\u7684\u7cfb\u7edf\u7ea7\u5347\u7ea7\u3002\u5927\u5bb9\u91cf\u6bb5\u6ea2\u4ef717%~21%\u6bd4\u4f8b\u66f4\u4f4e\uff0c\u66f4\u503c\u5f97\u6295\u5165\u3002\u8be6\u89c1 <a href=\"?page_id=1811\" style=\"color:var(--brand-red);font-weight:700\">\u5c0a\u777f\u5168\u6548\u2161\u5b8c\u6574\u8be6\u60c5\u9875 \u2192<\/a>\n      <\/div>\n      <div style=\"flex-shrink:0;width:200px;max-width:100%\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg\" alt=\"\u5c0a\u777f\u5168\u6548II\u65b0\u54c1\u4e0a\u5e02\" class=\"img-responsive img-shadow\" style=\"border-radius:8px\">\n        <div class=\"img-caption\"><a href=\"?page_id=1811\" style=\"color:var(--blue);font-weight:700\">\u5c0a\u777f\u5168\u6548\u2161\u65b0\u54c1\u8be6\u60c5 \u2192<\/a><\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u9009\u8d2d\u5efa\u8bae -->\n  <div class=\"rec-grid\">\n    <div class=\"rec-card r1\">\n      <div class=\"rc-icon\">\ud83c\udfe1<\/div>\n      <div class=\"rc-type\">\u9884\u7b97\u4f18\u5148 \u00b7 \u5e38\u89c4\u6c14\u5019<\/div>\n      <div class=\"rc-series\">\u8212\u4eab\u53cc\u98ce\u6247<\/div>\n      <div class=\"rc-reason\">\n        <strong>\u63a8\u8350200\u578b\u4e3a\u9996\u9009<\/strong>\uff08+3.5%\u83b7\u5f97+2kW\u5236\u51b7\uff0c\u751c\u70b9\u673a\u578b\uff09<br><br>\n        \u53cc\u8f6c\u5b50\u538b\u7f29\u673aAPF 5.0+\uff0c\u4e00\u7ea7\u80fd\u6548<br>\n        -20\u2103\u5236\u70ed\u8986\u76d6\u6210\u90fd\u51ac\u5b63<br>\n        -5~52\u2103\u5236\u51b7\u8986\u76d6\u6210\u90fd\u590f\u5b63<br>\n        \u539a\u5ea6320mm\u66f4\u8584\u66f4\u6613\u5b89\u88c5<br>\n        \u4ef7\u683c\u6700\u4f18\uff0c\u6027\u80fd\u591f\u7528\n      <\/div>\n    <\/div>\n    <div class=\"rec-card r2\">\n      <div class=\"rc-icon\">\ud83c\udff0<\/div>\n      <div class=\"rc-type\">\u6027\u80fd\u4f18\u5148 \u00b7 \u7cfb\u7edf\u5347\u7ea7<\/div>\n      <div class=\"rc-series\">\u5c0a\u777f\u5168\u6548\u2161<\/div>\n      <div class=\"rc-reason\">\n        <strong>\u5927\u5bb9\u91cf\u6bb5\u6ea2\u4ef7\u4ec517%~21%<\/strong>\uff0c\u6bd4\u5c0f\u5bb9\u91cf\u6bb526%\u66f4\u503c\u5f97<br><br>\n        \u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a<br>\n        APF\u63d0\u53477%~10%<br>\n        -25\u2103\u5236\u70ed \/ 60\u2103\u5236\u51b7<br>\n        \u6e29\u6e7f\u53cc\u63a7+\u6c34\u6a21\u5757\u6269\u5c55<br>\n        \u566a\u97f3\u964d\u4f4e2~3dB\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"sum-card\">\n    <div class=\"sc-title\">\ud83d\udccb \u51b3\u7b56\u6e05\u5355<\/div>\n    <div class=\"sc-item\"><span class=\"sc-ic\">1\ufe0f\u20e3<\/span><div><strong>\u540c\u5f00\u7387\u4f4e\uff1f<\/strong>\u2192 \u8212\u4eab\u53cc\u98ce\u6247\u3002\u540c\u5f00\u7387\u9ad8\uff1f\u2192 \u5c0a\u777f\u5168\u6548\u2161<\/div><\/div>\n    <div class=\"sc-item\"><span class=\"sc-ic\">2\ufe0f\u20e3<\/span><div><strong>\u6210\u90fd\u5e73\u539f\u5e38\u89c4\u6c14\u5019\uff1f<\/strong>\u2192 \u8212\u4eab\u591f\u7528\u3002\u6781\u7aef\u6c14\u5019\u5730\u533a\uff1f\u2192 \u5c0a\u777f\u5168\u6548\u2161<\/div><\/div>\n    <div class=\"sc-item\"><span class=\"sc-ic\">3\ufe0f\u20e3<\/span><div><strong>\u9700\u8981\u5929\u6c1f\u5730\u6c34\/\u6e29\u6e7f\u53cc\u63a7\uff1f<\/strong>\u2192 \u5c0a\u777f\u5168\u6548\u2161\uff08\u8212\u4eab\u53cc\u98ce\u6247\u4e0d\u652f\u6301\uff09<\/div><\/div>\n    <div class=\"sc-item\"><span class=\"sc-ic\">4\ufe0f\u20e3<\/span><div><strong>\u9009\u8212\u4eab\uff1f<\/strong>\u2192 \u4f18\u5148200\u578b\uff08\u751c\u70b9\uff09\uff0c\u9884\u7b97\u7d27\u9009180\u578b\uff0c\u6700\u5927\u9700\u6c42\u9009224\u578b<\/div><\/div>\n    <div class=\"sc-item\"><span class=\"sc-ic\">5\ufe0f\u20e3<\/span><div><strong>\u9009\u5c0a\u777f\uff1f<\/strong>\u2192 \u5927\u5bb9\u91cf\u6bb5\u6ea2\u4ef7\u6536\u7a84\uff0817%~21%\uff09\uff0c\u6bd4\u5c0f\u5bb9\u91cf\u6bb5\u66f4\u503c\u5f97\u6295\u5165<\/div><\/div>\n  <\/div>\n  <\/div><!-- \/.collapse-wrap -->\n<\/section>\n\n<!-- ===== \u00a77 \u7075\u6d3b\u8bbe\u8ba1\u4e0e\u5b89\u88c5 ===== -->\n<section class=\"sec\" id=\"s7\">\n  <div class=\"sh\"><div class=\"snum\">7<\/div><h2 class=\"stitle\">\u7075\u6d3b\u8bbe\u8ba1 \u00b7 \u5b89\u88c5\u65e0\u5fe7<\/h2><\/div>\n\n  <div style=\"display:flex;gap:18px;margin-bottom:18px;flex-wrap:wrap\">\n    <div class=\"card\" style=\"flex:1;min-width:280px;padding:16px\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-01.jpeg\" alt=\"\u7d27\u51d1\u673a\u8eab\u5b89\u88c5\u793a\u4f8b\" class=\"img-responsive img-shadow\" style=\"border-radius:8px;margin-bottom:10px\">\n      <div style=\"font-size:13px;color:var(--text2);line-height:1.7\">320mm\u8d85\u8584\u673a\u8eab\uff0c\u8f7b\u677e\u5e94\u5bf9\u9e3d\u5b50\u7b3c\u3001\u5916\u673a\u4f4d\u903c\u4ec4\u7b49\u7279\u6b8a\u5b89\u88c5\u73af\u5883\u3002\u53cc\u98ce\u6247\u5f3a\u52b2\u6392\u98ce101~122m\u00b3\/min\u3002<\/div>\n    <\/div>\n    <div class=\"card\" style=\"flex:1;min-width:280px;padding:16px\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg\" alt=\"\u5927\u6237\u65b9\u6848\u5c55\u793a\" class=\"img-responsive img-shadow\" style=\"border-radius:8px;margin-bottom:10px\">\n      <div style=\"font-size:13px;color:var(--text2);line-height:1.7\">\u6700\u591a\u4e00\u62d612\u53f0\u5185\u673a\u81ea\u7531\u7ec4\u5408\uff0c80m\u6700\u957f\u914d\u7ba1\u300150m\u6700\u5927\u9ad8\u4f4e\u5dee\u3002\u5927\u5e73\u5c42\/\u522b\u5885\u5168\u5c4b\u8986\u76d6\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"tech-grid\">\n    <div class=\"tech-card\">\n      <div class=\"tc-icon\">\ud83d\udcd0<\/div>\n      <div class=\"tc-title\">\u53cc\u98ce\u6247\u7d27\u51d1\u673a\u8eab<\/div>\n      <div class=\"tc-desc\">320mm\u6700\u5c0f\u539a\u5ea6\uff0c1380mm\u9ad8\u5ea6\u3002\u5efa\u8bae\u9884\u7559\u81f3\u5c111600mm\u5b89\u88c5\u9ad8\u5ea6\u3002\u53cc\u98ce\u6247\u5f3a\u52b2\u6392\u98ce101~122m\u00b3\/min\uff0c\u6392\u70ed\u6548\u7387\u8fdc\u8d85\u5355\u98ce\u6247\u65b9\u6848\u3002<\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <div class=\"tc-icon\">\ud83c\udfe0<\/div>\n      <div class=\"tc-title\">\u8d85\u8584\u5185\u673a\u91ca\u653e\u7a7a\u95f4<\/div>\n      <div class=\"tc-desc\">550mm\u6700\u5c0f\u7a84\u673a\u8eab + 192mm\u8d85\u8584 + 447mm\u6d45\u8fdb\u6df1\u3002\u8282\u7701\u7ea61\u33a1\u540a\u9876\u7a7a\u95f4\uff0c\u53ef\u642d\u8f7dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u3002<\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <div class=\"tc-icon\">\ud83c\udf73<\/div>\n      <div class=\"tc-title\">\u53a8\u623f\u4e13\u7528\u5d4c\u5165\u5f0f<\/div>\n      <div class=\"tc-desc\">IP44\u9632\u6cb9\u70df\u7b49\u7ea7\uff0c\u52a0\u539a\u9632\u8150\u8680\u7fc5\u7247\u3002\u5d4c\u5165\u5f0f\u5b89\u88c5\u4e0d\u5360\u540a\u67dc\u7a7a\u95f4\uff0c\u72ec\u7acb\u56de\u98ce\u8bbe\u8ba1\u907f\u514d\u6cb9\u70df\u4e32\u5473\u3002<\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <div class=\"tc-icon\">\ud83d\udec1<\/div>\n      <div class=\"tc-title\">\u536b\u6d74\u4e13\u7528\u4e09\u5408\u4e00<\/div>\n      <div class=\"tc-desc\">\u7a7a\u8c03+\u53d6\u6696+\u6392\u6c14\u4e09\u5408\u4e00\u529f\u80fd\uff0cIPX4\u9632\u6c34\u7b49\u7ea7\u3002\u51ac\u5b63\u5feb\u901f\u5347\u6e29\uff0c\u6885\u96e8\u5b63\u5f3a\u529b\u9664\u6e7f\uff0c\u4e00\u5e74\u56db\u5b63\u4e0d\u95f2\u7f6e\u3002<\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <div class=\"tc-icon\">\ud83c\udf2c\ufe0f<\/div>\n      <div class=\"tc-title\"><a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\" style=\"color:var(--blue);text-decoration:underline\">3D\u98ce\u53e3 \u00b7 \u98ce\u968f\u4eba\u52a8<\/a><\/div>\n      <div class=\"tc-desc\">\u7ebf\u6027\u8bbe\u8ba13D\u51fa\u98ce\u53e3\uff0c\u652f\u6301\u4e0a\u4e0b\u5de6\u53f3\u81ea\u52a8\u6446\u98ce\u3002\u907f\u514d\u51b7\u98ce\u76f4\u5439\u4eba\u4f53\uff0c\u9001\u98ce\u5747\u5300\u65e0\u6b7b\u89d2\u3002<a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\" style=\"color:var(--blue);font-size:12px\">\u67e5\u770b3D\u98ce\u53e3\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n    <div class=\"tech-card\">\n      <div class=\"tc-icon\">\ud83d\udccf<\/div>\n      <div class=\"tc-title\">\u8d85\u957f\u914d\u7ba1 \u00b7 \u591a\u79cd\u5185\u673a<\/div>\n      <div class=\"tc-desc\">80m\u6700\u957f\u914d\u7ba1\u300150m\u6700\u5927\u9ad8\u4f4e\u5dee\u30029~12\u53f0\u5185\u673a\u81ea\u7531\u7ec4\u5408\uff1a\u8d85\u8584\u98ce\u7ba1\u673a\/\u58c1\u6302\u673a\/\u5d4c\u5165\u5f0f\/\u53a8\u623f\u4e13\u7528\/\u536b\u6d74\u4e13\u7528\u3002<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a78 \u667a\u80fd\u63a7\u5236\u4e0e\u51c0\u5316 ===== -->\n  <div style=\"margin-bottom:18px;display:flex;gap:18px;flex-wrap:wrap;align-items:flex-start\">\n    <div style=\"flex:1;min-width:260px\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p15-01.jpeg\" alt=\"\u8fdc\u7a0b\u63a7\u5236\u667a\u80fd\u58f0\u63a7\" class=\"img-responsive img-shadow\" style=\"border-radius:12px\">\n      <div class=\"img-caption\">\u667a\u80fd\u58f0\u63a7 + WiFi\u8fdc\u7a0b \u00b7 \u5168\u5c4b\u667a\u80fd\u8054\u52a8<\/div>\n    <\/div>\n    <div style=\"flex:1;min-width:260px\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p15-02.jpeg\" alt=\"wifi\u63a7\u5236\" class=\"img-responsive img-shadow\" style=\"border-radius:12px\">\n      <div class=\"img-caption\">\u624b\u673a\u667a\u5bb6APP\u8fdc\u7a0b\u638c\u63a7<\/div>\n    <\/div>\n  <\/div>\n\n<section class=\"sec\" id=\"s8\">\n  <div class=\"sh\"><div class=\"snum\">8<\/div><h2 class=\"stitle\">\u667a\u80fd\u63a7\u5236\u4e0e\u7a7a\u6c14\u51c0\u5316<\/h2><\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\">\ud83d\udcf1 \u4fbf\u6377\u667a\u63a7<\/div>\n    <table class=\"dt\">\n      <thead><tr><th>\u63a7\u5236\u65b9\u5f0f<\/th><th>\u529f\u80fd\u63cf\u8ff0<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"label\">\ud83d\udce1 WiFi\u8fdc\u7a0b\u667a\u63a7<\/td><td style=\"text-align:left;font-size:13px\">\u624b\u673a\u667a\u5bb6APP\u8fdc\u7a0b\u5f00\u5173\u3001\u8c03\u6e29\u3001\u6a21\u5f0f\u5207\u6362\u3001\u5b9a\u65f6\u3002\u9700\u9009\u914dWiFi\u578b\u7ebf\u63a7\u5668<\/td><\/tr>\n        <tr><td class=\"label\">\ud83d\udda5\ufe0f \u667a\u6167\u96c6\u63a7\u5c4f<\/td><td style=\"text-align:left;font-size:13px\">4\u5bf8\u667a\u6167\u96c6\u63a7\u5c4f\u3002Mini Modbus\u8f6c\u6362\u5668\u63a5\u5165\u7c73\u5bb6\/\u5168\u5c4b\u667a\u80fd\u7cfb\u7edf<\/td><\/tr>\n        <tr><td class=\"label\">\ud83e\udee7 \u7a7a\u6c14\u76d2\u5b50<\/td><td style=\"text-align:left;font-size:13px\">\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u5b9e\u65f6\u76d1\u6d4b\uff08\u6e29\u6e7f\u5ea6\/PM2.5\/VOC\uff09\u3002\u6570\u636e\u8054\u52a8\u7a7a\u8c03\u81ea\u52a8\u8c03\u8282<\/td><\/tr>\n        <tr><td class=\"label\">\ud83d\udde3\ufe0f \u8bed\u97f3\u58f0\u63a7<\/td><td style=\"text-align:left;font-size:13px\">\u652f\u6301\u534e\u4e3a\/\u5c0f\u7c73\/\u767e\u5ea6\u7b49\u4e3b\u6d41\u667a\u80fd\u97f3\u7bb1\u8bed\u97f3\u63a7\u5236<\/td><\/tr>\n        <tr><td class=\"label\">\ud83c\udfe0 \u5168\u5c4b\u667a\u80fd\u8054\u52a8<\/td><td style=\"text-align:left;font-size:13px\">Mini Modbus\u8f6c\u6362\u5668\u63a5\u5165\u7c73\u5bb6\u7cfb\u7edf\uff0c\u706f\u5149\/\u7a97\u5e18\/\u573a\u666f\u6a21\u5f0f\u8054\u52a8<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\">\ud83c\udf3f PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff08\u9009\u914d\uff09<\/div>\n    <table class=\"dt\">\n      <thead><tr><th>\u51c0\u5316\u529f\u80fd<\/th><th>\u6548\u679c<\/th><th>\u68c0\u6d4b\u673a\u6784<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"label\">\u9664PM2.5<\/td><td class=\"hl-g\">\u53bb\u9664\u7387 99%<\/td><td>\u5317\u91cc\u7814\u7a76\u6240<\/td><\/tr>\n        <tr><td class=\"label\">\u9664\u7532\u919b<\/td><td class=\"hl-g\">88.6%<\/td><td>SGS<\/td><\/tr>\n        <tr><td class=\"label\">\u9664\u75c5\u6bd2<\/td><td class=\"hl-r\">H3N2 \u706d\u6d3b\u7387 99.91%<\/td><td>SGS<\/td><\/tr>\n        <tr><td class=\"label\">\u9664\u5f02\u5473<\/td><td>\u4e09\u7532\u80fa 95.8%<\/td><td>SGS<\/td><\/tr>\n        <tr><td class=\"label\">\u9664\u8fc7\u654f\u539f<\/td><td class=\"hl-b\">\u732b\u76ae\u5c51 97.22%<\/td><td>\u5317\u91cc\u7814\u7a76\u6240<\/td><\/tr>\n        <tr><td class=\"label\">\u9632\u87a8\u9664\u9709<\/td><td>\u957f\u6548\u6291\u5236<\/td><td>\u2014<\/td><\/tr>\n        <tr><td class=\"label\">\u6d88\u9664\u9759\u7535<\/td><td>80%\u4ee5\u4e0a\u6d88\u9664<\/td><td>\u2014<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <div style=\"margin-top:12px;font-size:13px;color:var(--text3);line-height:1.7\">\n      \u4ea7\u54c1\u578b\u53f7\uff1aJK-LZA \u00b7 \u514d\u66f4\u6362\u65e0\u6ee4\u7f51\u8bbe\u8ba1\uff0c\u4e0e\u5ba4\u5185\u673a\u540c\u5bff\u547d \u00b7 \u4e3a\u9009\u914d\u4ef6\uff0c\u9700\u5355\u72ec\u9009\u8d2d\u3002<br>\n      \u8be6\u89c1 <a href=\"?page_id=2512\" style=\"color:var(--blue);font-weight:700\">PE+\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u8be6\u60c5\u9875 \u2192<\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a79 \u5ba4\u5185\u673a\u9009\u578b\u53c2\u8003 ===== -->\n<section class=\"sec\" id=\"s9\">\n  <div class=\"sh\"><div class=\"snum\">9<\/div><h2 class=\"stitle\">\u5ba4\u5185\u673a\u9009\u578b\u53c2\u8003<\/h2><\/div>\n\n  <div style=\"display:flex;gap:18px;margin-bottom:18px;flex-wrap:wrap\">\n    <div class=\"card\" style=\"flex:1;min-width:260px;padding:16px;text-align:center\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p10-13.jpeg\" alt=\"\u5185\u673a\u9009\u578b\u5c55\u793a\" class=\"img-responsive img-shadow\" style=\"border-radius:8px\">\n      <div class=\"img-caption\">\u8d85\u8584\u98ce\u7ba1\u673a \u00b7 192mm\u7ea4\u8584\u673a\u8eab<\/div>\n    <\/div>\n    <div class=\"card\" style=\"flex:1;min-width:260px;padding:16px;text-align:center\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p14-01.jpeg\" alt=\"\u5185\u673a\u9009\u578b\u5c55\u793a\" class=\"img-responsive img-shadow\" style=\"border-radius:8px\">\n      <div class=\"img-caption\">\u5d4c\u5165\u5f0f\/\u58c1\u6302\u5f0f\/\u53a8\u623f\u4e13\u7528 \u00b7 \u591a\u79cd\u5185\u673a\u81ea\u7531\u7ec4\u5408<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\">\ud83c\udfe0 \u5185\u673a\u5bb9\u91cf\u4e0e\u9762\u79ef\u5bf9\u5e94\u8868<\/div>\n    <table class=\"dt\">\n      <thead><tr><th>\u623f\u95f4\u9762\u79ef<\/th><th>\u5efa\u8bae\u5236\u51b7\u91cf<\/th><th>\u7ea6\u5339\u6570<\/th><th>\u53ef\u9009\u578b\u53f7\u540e\u7f00<\/th><th>\u63a8\u8350\u5185\u673a\u7c7b\u578b<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"label\">8~12\u33a1<\/td><td>2.2~2.8kW<\/td><td>\u7ea61\u5339<\/td><td>22 \/ 28<\/td><td>\u8584\u578b\u98ce\u7ba1\u5f0f \/ \u58c1\u6302\u5f0f<\/td><\/tr>\n        <tr><td class=\"label\">12~18\u33a1<\/td><td>3.2~4.0kW<\/td><td>\u7ea61.5\u5339<\/td><td>32 \/ 36 \/ 40<\/td><td>\u8584\u578b\u98ce\u7ba1\u5f0f \/ \u5d4c\u5165\u5f0f<\/td><\/tr>\n        <tr><td class=\"label\">18~25\u33a1<\/td><td>4.5~5.6kW<\/td><td>\u7ea62\u5339<\/td><td>45 \/ 50 \/ 56<\/td><td>\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><\/tr>\n        <tr><td class=\"label\">25~35\u33a1<\/td><td>6.3~7.1kW<\/td><td>\u7ea62.5~3\u5339<\/td><td>63 \/ 71<\/td><td>\u8584\u578b\u98ce\u7ba1\u5f0f \/ \u7ea4\u8584\u7011\u5f0f<\/td><\/tr>\n        <tr><td class=\"label\">35~50\u33a1<\/td><td>8.0~9.0kW<\/td><td>\u7ea63~4\u5339<\/td><td>80 \/ 90<\/td><td>90\u578b\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><\/tr>\n        <tr><td class=\"label\">\u53a8\u623f<\/td><td>2.2~4.0kW<\/td><td>1~1.5\u5339<\/td><td>22 \/ 32 \/ 40<\/td><td>\u53a8\u623f\u4e13\u7528\u5d4c\u5165\u5f0f\/\u98ce\u7ba1\u5f0f<\/td><\/tr>\n        <tr><td class=\"label\">\u536b\u6d74<\/td><td>2.5kW<\/td><td>\u7ea61\u5339<\/td><td>25<\/td><td>\u536b\u6d74\u4e13\u7528\u673a\uff08\u542b\u6392\u6c14\uff09<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"card\">\n    <div class=\"ct\">\ud83c\udfaf \u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u9009\u578b\u65b9\u6848\u53c2\u8003<\/div>\n    <table class=\"dt\">\n      <thead><tr><th>\u6237\u578b<\/th><th>\u9762\u79ef<\/th><th>\u63a8\u8350\u5916\u673a<\/th><th>\u5185\u673a\u65b9\u6848\u53c2\u8003<\/th><th>\u8d85\u914d\u7387<\/th><\/tr><\/thead>\n      <tbody>\n        <tr>\n          <td class=\"label\">\u4e09\u5ba4\u4e24\u5385+\u53a8\u536b<\/td><td>140~170\u33a1<\/td><td class=\"hl-g\">RAS-180HRNBQ<\/td>\n          <td style=\"text-align:left;font-size:12px\">22\u00d72 + 32 + 40 + 56 + 71 + \u53a8\u623f22<\/td><td>90%~110%<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">\u56db\u5ba4\u4e24\u5385+\u53a8\u536b<\/td><td>160~185\u33a1<\/td><td class=\"hl-b\">RAS-200HRNBQ<\/td>\n          <td style=\"text-align:left;font-size:12px\">22\u00d73 + 32 + 40 + 56 + 71 + \u53a8\u623f22 + \u536b\u6d7425<\/td><td>90%~110%<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"label\">\u5927\u5e73\u5c42\/\u522b\u5885<\/td><td>180~200\u33a1<\/td><td class=\"hl-y\">RAS-224HRNBQ<\/td>\n          <td style=\"text-align:left;font-size:12px\">22\u00d74 + 32\u00d72 + 45 + 63 + 71 + \u53a8\u623f32 + \u536b\u6d7425<\/td><td>90%~110%<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a710 \u5ba2\u6237\u6848\u4f8b\u5206\u4eab\uff08\u9884\u7559\uff09 ===== -->\n<section class=\"sec\" id=\"s10\">\n  <div class=\"sh\"><div class=\"snum\">10<\/div><h2 class=\"stitle\">\u5ba2\u6237\u6848\u4f8b\u5206\u4eab<\/h2><span class=\"stitle-sub\">\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf \u00b7 \u771f\u5b9e\u5b89\u88c5\u5b9e\u4f8b<\/span><\/div>\n\n  <div class=\"case-placeholder\">\n    <div class=\"cp-icon\">\ud83d\udcf8<\/div>\n    <div class=\"cp-title\">\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u6848\u4f8b\u6301\u7eed\u6536\u96c6\u4e2d<\/div>\n    <div class=\"cp-desc\">\n      \u6211\u4eec\u6b63\u5728\u6574\u7406\u5df2\u5b89\u88c5\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\uff08180\/200\/224\u578b\uff09\u7684\u5ba2\u6237\u6848\u4f8b\u2014\u2014\u5305\u62ec\u6237\u578b\u914d\u7f6e\u65b9\u6848\u3001\u5b89\u88c5\u5b9e\u62cd\u3001\u4f7f\u7528\u53cd\u9988\u3002<br><br>\n      <strong>\u5982\u679c\u60a8\u662f\u9f99\u8109\u6696\u901a\u7684\u8212\u4eab\u53cc\u98ce\u6247\u5ba2\u6237\uff0c\u6b22\u8fce\u5206\u4eab\u60a8\u7684\u4f7f\u7528\u4f53\u9a8c\uff01<\/strong><br>\n      \u60a8\u7684\u771f\u5b9e\u6848\u4f8b\u5c06\u5e2e\u52a9\u66f4\u591a\u5bb6\u5ead\u627e\u5230\u5408\u9002\u7684\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u3002\n    <\/div>\n    <div style=\"margin-top:20px\">\n      <a href=\"?page_id=2297\" class=\"cta-btn\" style=\"background:var(--gold);color:var(--dark)\">\ud83d\udccb \u67e5\u770b\u9f99\u8109\u6696\u901a\u5168\u90e8\u5ba2\u6237\u6848\u4f8b \u2192<\/a>\n    <\/div>\n  <\/div>\n\n  <div style=\"margin-top:18px;background:var(--card);border-radius:var(--radius);padding:20px 24px;box-shadow:var(--shadow);text-align:center\">\n    <div style=\"font-size:15px;font-weight:700;color:var(--dark);margin-bottom:10px\">\ud83d\udcac \u4e0d\u786e\u5b9a\u9009\u54ea\u4e2a\u578b\u53f7\uff1f<\/div>\n    <div style=\"font-size:14px;color:var(--text2)\">\u8bc4\u8bba\u7559<strong>\u300c\u6210\u90fd + \u9762\u79ef + \u540c\u5f00\u51e0\u53f0\u300d<\/strong>\uff0c\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u5e08\u5e2e\u4f60\u7cbe\u786e\u5339\u914d\u65b9\u6848<\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a711 \u65e5\u7acb\u4ea7\u54c1\u5bfc\u822a ===== -->\n<section class=\"sec\" id=\"s11\">\n  <div class=\"sh\"><div class=\"snum\">11<\/div><h2 class=\"stitle\">\u65e5\u7acb\u4ea7\u54c1\u8be6\u60c5\u9875\u5bfc\u822a<\/h2><\/div>\n\n  <div class=\"nav-grid\">\n    <a href=\"?page_id=1077\" class=\"nav-card\">\n      <span class=\"nc-icon\">\ud83d\udcd6<\/span>\n      <div>\n        <div class=\"nc-title\">\u65e5\u7acbEX-\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u624b\u518c<\/div>\n        <div class=\"nc-desc\">\u8212\u4eab\u5168\u7cfb\u5355\u98ce\u6247+\u53cc\u98ce\u6247\u5b8c\u6574\u53c2\u6570<\/div>\n      <\/div>\n    <\/a>\n    <a href=\"?page_id=2512\" class=\"nav-card\">\n      <span class=\"nc-icon\">\ud83c\udf3f<\/span>\n      <div>\n        <div class=\"nc-title\">PE+\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u8be6\u60c5\u9875<\/div>\n        <div class=\"nc-desc\">\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0cSGS\u00d7\u5317\u91cc\u53cc\u91cd\u8ba4\u8bc1<\/div>\n      <\/div>\n    <\/a>\n    <a href=\"?page_id=2543\" class=\"nav-card\">\n      <span class=\"nc-icon\">\ud83c\udfe1<\/span>\n      <div>\n        <div class=\"nc-title\">\u65e5\u7acbVAM\u5c0a\u777f\u522b\u5885\u7cfb\u5217<\/div>\n        <div class=\"nc-desc\">\u522b\u5885\u7ea7\u5168\u6548\u89e3\u51b3\u65b9\u6848\uff0c\u5929\u6c1f\u5730\u6c34\u4e00\u4f53\u673a<\/div>\n      <\/div>\n    <\/a>\n    <a href=\"?page_id=1811\" class=\"nav-card\">\n      <span class=\"nc-icon\">\ud83c\udfc6<\/span>\n      <div>\n        <div class=\"nc-title\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\u8be6\u60c5\u9875<\/div>\n        <div class=\"nc-desc\">\u6e29\u6e7f\u53cc\u63a7\u4e09\u7ba1\u5236\uff0c\u4e09\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf<\/div>\n      <\/div>\n    <\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\" class=\"nav-card\">\n      <span class=\"nc-icon\">\ud83c\udf2c\ufe0f<\/span>\n      <div>\n        <div class=\"nc-title\">\u65e5\u7acb3D\u98ce\u53e3\u8be6\u60c5\u9875<\/div>\n        <div class=\"nc-desc\">\u7ebf\u6027\u8bbe\u8ba13D\u51fa\u98ce\u53e3\uff0c\u4e0a\u4e0b\u5de6\u53f3\u81ea\u52a8\u6446\u98ce<\/div>\n      <\/div>\n    <\/a>\n    <a href=\"\/\" class=\"nav-card\">\n      <span class=\"nc-icon\">\ud83c\udfe0<\/span>\n      <div>\n        <div class=\"nc-title\">\u9f99\u8109\u6696\u901a\u5b98\u7f51\u9996\u9875<\/div>\n        <div class=\"nc-desc\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6210\u90fd\u6388\u6743\u7ecf\u9500\u5546<\/div>\n      <\/div>\n    <\/a>\n  <\/div>\n<\/section>\n\n<!-- ===== \u00a712 FAQ ===== -->\n<section class=\"sec\" id=\"s12\">\n  <div class=\"sh\"><div class=\"snum\">12<\/div><h2 class=\"stitle\">\u5e38\u89c1\u95ee\u9898 FAQ<\/h2><\/div>\n\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u5927\u5bb9\u91cf\u53cc\u98ce\u6247(180~224\u578b)\u548c\u6807\u51c6\u53cc\u98ce\u6247(125~160\u578b)\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/div>\n    <div class=\"faq-a\">\u5927\u5bb9\u91cf\u578b\u5236\u51b7\u91cf18.0~22.4kW\uff0c\u6807\u51c6\u578b12.5~16.0kW\u3002\u5927\u5bb9\u91cf\u578b\u6700\u591a\u8fde12\u53f0\u5185\u673a\uff08\u6807\u51c6\u578b7\u53f0\uff09\uff0c\u9002\u7528140~200\u33a1\u5927\u6237\u578b\u3002\u5236\u51b7\u8303\u56f4\u5927\u5bb9\u91cf\u578b-5~52\u2103\uff08\u6807\u51c6\u578b-5~59\u2103\uff09\uff0cAPF\u5927\u5bb9\u91cf\u578b\u6700\u9ad85.05\uff08\u6807\u51c6\u578b\u6700\u9ad86.10\uff09\u3002\u4e24\u5927\u7cfb\u5217\u5b9a\u4f4d\u4e92\u8865\uff1a\u6807\u51c6\u578b\u8986\u76d680~140\u33a1\uff0c\u5927\u5bb9\u91cf\u578b\u8986\u76d6140~200\u33a1\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u53cc\u98ce\u6247\u5916\u673a\u5b89\u88c5\u9700\u8981\u591a\u9ad8\u7a7a\u95f4\uff1f<\/div>\n    <div class=\"faq-a\">\u673a\u8eab\u9ad8\u5ea61380mm\uff0c\u5efa\u8bae\u9884\u7559\u81f3\u5c111600mm\u5b89\u88c5\u9ad8\u5ea6\uff08\u542b\u5e95\u5ea7\u548c\u4e0a\u65b9\u901a\u98ce\u7a7a\u95f4\uff09\u3002\u539a\u5ea6\u4ec5320mm\uff0c\u9002\u5408\u7eb5\u6df1\u53d7\u9650\u7684\u5916\u673a\u4f4d\u30020\/30Pa\u9759\u538b\u53ef\u8c03\u529f\u80fd\u53ef\u5e94\u5bf9\u901a\u98ce\u4e0d\u826f\u7684\u5b89\u88c5\u73af\u5883\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>0\/30Pa\u9759\u538b\u53ef\u8c03\u6709\u4ec0\u4e48\u7528\uff1f<\/div>\n    <div class=\"faq-a\">\u5916\u673a\u4f4d\u901a\u98ce\u4e0d\u7545\u65f6\uff08\u5982\u9e3d\u5b50\u7b3c\u3001\u767e\u53f6\u7a97\u5c01\u95ed\u8fc7\u5bc6\uff09\uff0c\u5207\u6362\u523030Pa\u6863\u53ef\u589e\u52a0\u6392\u98ce\u538b\u529b\uff0c\u5c06\u70ed\u98ce\u5439\u5f97\u66f4\u8fdc\u3001\u907f\u514d\u70ed\u98ce\u56de\u6d41\u5bfc\u81f4\u5236\u51b7\u6548\u7387\u4e0b\u964d\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u80fd\u4e0d\u80fd\u505a\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\uff1f<\/div>\n    <div class=\"faq-a\"><strong>\u4e0d\u80fd\u3002<\/strong>\u8212\u4eab\u53cc\u98ce\u6247\u4e0d\u652f\u6301\u8fde\u63a5\u6c34\u6a21\u5757\uff0c\u65e0\u6cd5\u5b9e\u73b0\u5929\u6c1f\u5730\u6c34\uff08\u7a7a\u8c03+\u5730\u6696\u4e8c\u5408\u4e00\uff09\u3002\u5982\u9700\u5929\u6c1f\u5730\u6c34\/\u4e09\u8054\u4f9b\u7cfb\u7edf\uff0c\u8bf7\u9009\u62e9<a href=\"?page_id=2543\" style=\"color:var(--brand-red);font-weight:700\">\u65e5\u7acbVAM\u5c0a\u777f\u522b\u5885\u7cfb\u5217<\/a>\u6216<a href=\"?page_id=1811\" style=\"color:var(--brand-red);font-weight:700\">\u5c0a\u777f\u5168\u6548\u2161<\/a>\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u548c\u5c0a\u777f\u5168\u6548\u600e\u4e48\u9009\uff1f<\/div>\n    <div class=\"faq-a\">\u8be6\u89c1\u672c\u9875\u7b2c\u516d\u7ae0\u5b8c\u6574\u5bf9\u6bd4\u5206\u6790\u3002\u7b80\u800c\u8a00\u4e4b\uff1a\u6210\u90fd\u5e38\u89c4\u6c14\u5019+\u9884\u7b97\u4f18\u5148\u2192\u8212\u4eab\u53cc\u98ce\u6247\uff08\u63a8\u8350200\u578b\u751c\u70b9\uff09\uff1b\u6781\u7aef\u6c14\u5019+\u7cfb\u7edf\u5347\u7ea7\u9700\u6c42\u2192\u5c0a\u777f\u5168\u6548\u2161\uff08\u5927\u5bb9\u91cf\u6bb5\u6ea2\u4ef7\u4ec517%~21%\u66f4\u503c\u5f97\uff09\u3002\u6838\u5fc3\u5dee\u5f02\u5728\u538b\u7f29\u673a\uff08\u53cc\u8f6c\u5b50 vs \u8865\u6c14\u589e\u7113\u6da1\u65cb\uff09\u548c\u7cfb\u7edf\u6269\u5c55\u80fd\u529b\uff08\u4e0d\u652f\u6301 vs \u652f\u6301\u6c34\u6a21\u5757\/\u6e29\u6e7f\u53cc\u63a7\uff09\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>APF 5.05\u548c5.00\u5dee\u8ddd\u5927\u5417\uff1f<\/div>\n    <div class=\"faq-a\">\u5dee\u8ddd\u5f88\u5c0f\u3002APF 0.05\u7684\u5dee\u5f02\u5728\u5168\u5e74\u7535\u8d39\u4e0a\u7ea6\u5dee50~100\u5143\/\u5e74\uff0c\u51e0\u4e4e\u53ef\u5ffd\u7565\u3002180\u578bAPF 5.05\u662f\u4e09\u6b3e\u4e2d\u80fd\u6548\u6700\u9ad8\u7684\uff0c\u4f46\u9009\u8d2d\u65f6\u66f4\u5e94\u5173\u6ce8\u5236\u51b7\u91cf\u662f\u5426\u5339\u914d\u6237\u578b\u9700\u6c42\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>224\u578b\u6700\u591a\u8fde12\u53f0\u5185\u673a\uff0c\u8d85\u914d\u7387\u5f88\u5173\u952e\u5417\uff1f<\/div>\n    <div class=\"faq-a\">\u662f\u7684\u3002\u5927\u6237\u578b\u540c\u5f00\u7387\u901a\u5e38\u8f83\u4f4e\uff0c\u8d85\u914d\u7387\uff08\u5185\u673a\u603b\u5bb9\u91cf\u00f7\u5916\u673a\u5bb9\u91cf\uff09\u53ef\u9002\u5f53\u653e\u5bbd\u5230110%~130%\u3002\u4f46\u5efa\u8bae\u63a7\u5236\u572890%~110%\u6700\u4f18\u533a\u95f4\uff0c\u4ee5\u4fdd\u8bc1\u5168\u5f00\u65f6\u6bcf\u53f0\u5185\u673a\u6548\u679c\u3002\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u5e08\u4f1a\u6839\u636e\u5b9e\u9645\u4f7f\u7528\u573a\u666f\u7cbe\u786e\u8ba1\u7b97\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u6709\u4ec0\u4e48\u7279\u522b\u4e4b\u5904\uff1f<\/div>\n    <div class=\"faq-a\">\"\u5168\u98ce\u8def\u51c0\u5316\u8231\"\u8bbe\u8ba1\u2014\u2014\u4e0d\u662f\u7b80\u5355\u5728\u51fa\u98ce\u53e3\u52a0\u6ee4\u7f51\uff0c\u800c\u662f\u5c06\u6574\u4e2a\u5ba4\u5185\u673a\u98ce\u9053\u8bbe\u8ba1\u4e3a\u51c0\u5316\u901a\u9053\u3002\u514d\u66f4\u6362\u65e0\u6ee4\u7f51\u8bbe\u8ba1\uff0c\u4e0e\u5ba4\u5185\u673a\u540c\u5bff\u547d\u3002SGS\u00d7\u5317\u91cc\u7814\u7a76\u6240\u53cc\u91cd\u8ba4\u8bc1\u3002\u8be6\u89c1<a href=\"?page_id=2512\" style=\"color:var(--blue);font-weight:700\">PE+\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u8be6\u60c5\u9875 \u2192<\/a><\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u4e3a\u4ec0\u4e48\u9009\u62e9\u9f99\u8109\u6696\u901a\u5b89\u88c5\uff1f<\/div>\n    <div class=\"faq-a\">\u9f99\u8109\u6696\u901a\u6210\u7acb\u4e8e2004\u5e74\uff0c\u662f\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6210\u90fd\u6388\u6743\u7ecf\u9500\u5546\uff0c\u670d\u52a1\u6210\u90fd\u5e02\u573a\u8d85\u8fc720\u5e74\u3002\u62e5\u6709\u81ea\u6709\u5b89\u88c5\u56e2\u961f\uff08\u975e\u5916\u5305\uff09\uff0c\u6807\u51c6\u5316\u65bd\u5de5\u6d41\u7a0b\uff0c\u5df2\u4e3a\u6570\u767e\u4e2a\u6210\u90fd\u5bb6\u5ead\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u5168\u6848\u670d\u52a1\u3002\u5168\u7ebf\u4ea7\u54c1\u4eab\u53d7\u65e5\u7acb\u5b98\u65b9\u8d28\u4fdd+\u9f99\u8109\u6696\u901a\u957f\u671f\u670d\u52a1\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u548c\u5c0a\u777f\u522b\u5885\u7cfb\u5217\u600e\u4e48\u9009\uff1f<\/div>\n    <div class=\"faq-a\"><strong>\u5b9a\u4f4d\u5b8c\u5168\u4e0d\u540c\u3002<\/strong>\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf=\u5927\u6237\u578b\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\uff0c\u5c0a\u777f\u522b\u5885=\u522b\u5885\u7ea7\u5168\u6548\u7cfb\u7edf\uff08\u652f\u6301\u5929\u6c1f\u5730\u6c34\/\u4e09\u8054\u4f9b\uff09\u3002<br><br><strong>\u9009\u8212\u4eab\u5927\u5bb9\u91cf\uff1a<\/strong>\u53ea\u9700\u4e2d\u592e\u7a7a\u8c03\u5236\u51b7+\u5236\u70ed\uff0c\u4e0d\u6d89\u53ca\u5730\u6696\/\u751f\u6d3b\u70ed\u6c34\u3002<br><strong>\u9009\u5c0a\u777f\u522b\u5885\uff1a<\/strong>\u9700\u8981\u7a7a\u8c03+\u5730\u6696+\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53\u5316\uff0c\u6216\u4e94\u6052\u7cfb\u7edf\u5168\u5c4b\u96c6\u6210\u3002\u4e24\u8005\u4e0d\u662f\"\u8c01\u66f4\u597d\"\uff0c\u800c\u662f\"\u4f60\u8981\u4e0d\u8981\u5730\u6696\u548c\u6c34\u7cfb\u7edf\"\u3002\u8be6\u89c1<a href=\"?page_id=2543\" style=\"color:var(--brand-red);font-weight:700\">\u65e5\u7acbVAM\u5c0a\u777f\u522b\u5885\u7cfb\u5217\u8be6\u60c5\u9875 \u2192<\/a><\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u548c\u8212\u4eab\u5355\u98ce\u6247\u540c\u6237\u578b\u600e\u4e48\u9009\uff1f<\/div>\n    <div class=\"faq-a\">\u4e24\u8005\u6709\u5bb9\u91cf\u91cd\u53e0\u6bb5\uff08140~160\u578b\uff09\u3002<strong>\u5355\u98ce\u6247140\/160\u578b\uff1a<\/strong>APF\u6700\u9ad86.10\u3001\u566a\u97f3\u66f4\u4f4e\uff0850~56dB\uff09\u3001\u5236\u51b7\u8303\u56f4\u66f4\u5bbd\uff08-5~59\u2103\uff09\uff0c\u9002\u5408\u5bf9\u80fd\u6548\u548c\u9759\u97f3\u8981\u6c42\u66f4\u9ad8\u7684\u7528\u6237\u3002<strong>\u53cc\u98ce\u6247\u5927\u5bb9\u91cf180~224\u578b\uff1a<\/strong>\u66f4\u5927\u5236\u51b7\u91cf\uff0818.0~22.4kW\uff09\u3001\u6700\u591a12\u53f0\u5185\u673a\u3001\u53cc\u98ce\u6247\u66f4\u5f3a\u6392\u98ce\uff0c\u9002\u5408\u5927\u5e73\u5c42\/\u522b\u5885\u3002\u5982\u679c\u6237\u578b\u521a\u597d140\u33a1\u5de6\u53f3\uff0c\u53ef\u9009\u5355\u98ce\u6247160\u578b\uff08\u591f\u7528\u4e14\u66f4\u9759\u97f3\uff09\uff0c\u6216\u53cc\u98ce\u6247180\u578b\uff08\u7559\u6709\u6269\u5bb9\u4f59\u91cf\uff09\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u548cEX-PRO\u5dee\u5728\u54ea\u91cc\uff1f<\/div>\n    <div class=\"faq-a\">EX-PRO\u662f\u65e5\u7acbEX\u5e73\u53f0\u7684\u5165\u95e8\u7ea7\u4ea7\u54c1\uff0c\u5bb9\u91cf\u4ec5\u8986\u76d680~160\u578b\uff08\u226416.0kW\uff09\u3002<strong>\u6838\u5fc3\u5dee\u5f02\uff1a<\/strong>\u2460EX-PRO\u65e0\u5927\u5bb9\u91cf\u6bb5\uff08\u6700\u5927160\u578b\uff0c\u4e0d\u80fd\u8986\u76d6140\u33a1\u4ee5\u4e0a\u5927\u6237\u578b\uff09\uff1b\u2461EX-PRO\u65e0\u53cc\u98ce\u6247\u8bbe\u8ba1\uff0c\u6392\u98ce\u80fd\u529b\u76f8\u5bf9\u5f31\uff1b\u2462EX-PRO\u65e00\/30Pa\u9759\u538b\u53ef\u8c03\u3002\u4e00\u53e5\u8bdd\uff1aEX-PRO\u662f\u4e2d\u5c0f\u6237\u578b\u5165\u95e8\u65b9\u6848\uff0c\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u662f\u53ef\u4ee5\u8986\u76d6140~250\u33a1\u5c45\u5bb6\u7684\u8212\u4eab\u65b9\u6848\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>\u5b89\u88c5\u9700\u8981\u591a\u5927\u7535\u6d41\uff1f\u7535\u8868\u591f\u7528\u5417\uff1f<\/div>\n    <div class=\"faq-a\"><strong>180\/200\u578b\uff1a<\/strong>\u6700\u5927\u7194\u4e1d\u7535\u6d4140A\uff0c\u6700\u5c0f\u7ebf\u8def\u7535\u6d4132A\u3002\u666e\u901a\u5bb6\u5ead6mm\u00b2\u94dc\u82af\u7ebf+40A\u7a7a\u6c14\u5f00\u5173\u5373\u53ef\u6ee1\u8db3\u3002<br><strong>224\u578b\uff1a<\/strong>\u6700\u5927\u7194\u4e1d\u7535\u6d4150A\uff0c\u6700\u5c0f\u7ebf\u8def\u7535\u6d4140A\u3002\u5efa\u8bae10mm\u00b2\u94dc\u82af\u7ebf+50A\u7a7a\u6c14\u5f00\u5173\u3002\u6210\u90fd\u5927\u591a\u6570\u4f4f\u5b85\u7535\u8868\u4e3a60A\u6216\u4ee5\u4e0a\uff0c\u4e09\u6b3e\u5747\u53ef\u5b89\u88c5\u3002\u5b89\u88c5\u524d\u9f99\u8109\u6696\u901a\u5de5\u7a0b\u5e08\u4f1a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u7535\u8868\u5bb9\u91cf\u548c\u7ebf\u8def\u6761\u4ef6\u3002<\/div>\n  <\/div>\n  <div class=\"faq-item\">\n    <div class=\"faq-q\" onclick=\"toggleFaq(this)\"><span class=\"faq-arrow\">\u25bc<\/span>3D\u98ce\u53e3\u6709\u4ec0\u4e48\u7528\uff1f\u8212\u4eab\u5927\u5bb9\u91cf\u914d\u4ec0\u4e48\u98ce\u53e3\uff1f<\/div>\n    <div class=\"faq-a\">\u65e5\u7acb<a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\" style=\"color:var(--blue);font-weight:700\">3D\u98ce\u53e3<\/a>\u652f\u6301\u4e0a\u4e0b\u5de6\u53f3\u81ea\u52a8\u6446\u98ce\uff0c\u907f\u514d\u51b7\u98ce\u76f4\u5439\u4eba\u4f53\uff0c\u9001\u98ce\u5747\u5300\u65e0\u6b7b\u89d2\u3002\u7279\u522b\u9002\u5408\u6709\u8001\u4eba\/\u5c0f\u5b69\u7684\u5bb6\u5ead\u3001\u4ee5\u53ca\u5f00\u653e\u5f0f\u5927\u7a7a\u95f4\u3002\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u914d\u59573D\u98ce\u53e3\u6548\u679c\u66f4\u4f73\u3002\u8be6\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\" style=\"color:var(--blue);font-weight:700\">3D\u98ce\u53e3\u8be6\u60c5\u9875 \u2192<\/a><\/div>\n  <\/div>\n<\/section>\n<div style=\"margin:26px 0;padding:16px 18px;background:#f6f8fa;border-left:4px solid #1a2b3c;border-radius:8px;\" data-page-node-id=\"jgwzhbAV6K4t5OBY3a37Nq\">\n  <div style=\"font-size:15px;font-weight:700;color:#1a2b3c;margin-bottom:6px;\" data-page-node-id=\"CDhXQmPyEyboIIKdR2HRII\">\u8fd9\u53f0\u673a\u5668\u9002\u5408\u4f60\u5bb6\u5417\uff1f\u5148\u770b\u9009\u578b\u903b\u8f91<\/div>\n  <div style=\"font-size:14px;line-height:1.8;color:#3c4d5c;margin-bottom:10px;\" data-page-node-id=\"mlFliZj06IYHFAojusWoRv\">\n    \u5355\u54c1\u53c2\u6570\u53ea\u8bf4\u660e\"\u5b83\u662f\u4ec0\u4e48\"\uff0c\u6237\u578b\u9762\u79ef\u3001\u671d\u5411\u3001\u5c42\u9ad8\u3001\u662f\u5426\u88c5\u5730\u6696\u624d\u51b3\u5b9a\"\u4f60\u8be5\u9009\u54ea\u53f0\"\u3002\u767d\u76ae\u4e66\u91cc\u6709\u5b8c\u6574\u7684\u8d1f\u8377\u7b97\u6cd5\u4e0e\u8d85\u914d\u7387\u533a\u95f4\u3002\n  <\/div>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"display:inline-block;padding:9px 15px;background:#1a2b3c;color:#fff;border-radius:6px;text-decoration:none;font-size:14px;font-weight:600;\" data-page-node-id=\"o15L9UmJ3X65ZyE3H29A6I\">\n    \u67e5\u9009\u578b\u65b9\u6cd5\u4e0e\u56fd\u6807\u8d1f\u8377\uff1a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66\n  <\/a>\n<\/div>\n\n<!-- ===== CTA Section ===== -->\n<div class=\"cta-section\">\n  <h3>\ud83d\udcde \u83b7\u53d6\u4e13\u5c5e\u65b9\u6848<\/h3>\n  <p>\u4e0d\u786e\u5b9a\u9009180\/200\/224\u54ea\u4e2a\u578b\u53f7\uff1f\u4e0d\u786e\u5b9a\u8212\u4eab\u8fd8\u662f\u5c0a\u777f\u66f4\u9002\u5408\uff1f<br>\u7559\u4e0b\u6237\u578b\u4fe1\u606f\uff0c\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u5e08\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u51fa\u5177\u4e00\u5bf9\u4e00\u65b9\u6848\u3002<\/p>\n  <a href=\"tel:028-86131795\" class=\"cta-btn\">\ud83d\udcde \u81f4\u7535\u54a8\u8be2\uff1a028-86131795<\/a>\n<\/div>\n\n<!-- ===== Store Info ===== -->\n<div class=\"card\" style=\"margin-top:18px\">\n  <div class=\"ct\"><span class=\"ct-ico\">\ud83d\udccd<\/span>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6210\u90fd\u95e8\u5e97 \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n  <div class=\"store-grid\">\n    <div class=\"store-card\">\n      <div class=\"sn\">\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97<\/div>\n      <div class=\"sa\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/div>\n      <div class=\"sp\">\u8303\u7ecf\u7406 133-9819-8375 \/ \u90ed\u7ecf\u7406 181-0083-9248<\/div>\n    <\/div>\n    <div class=\"store-card\">\n      <div class=\"sn\">\u6210\u534e\u533a\u5e97<\/div>\n      <div class=\"sa\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/div>\n      <div class=\"sp\">\u9ec4\u7ecf\u7406 158-2848-9188 \/ \u4f59\u7ecf\u7406 139-0818-3204<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<\/div><!-- \/.cv -->\n<\/div><!-- \/.mc -->\n\n<!-- ===== Footer ===== -->\n<footer class=\"page-footer\">\n  <div class=\"pf-row\">\n    <a href=\"?page_id=1077\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u624b\u518c<\/a><span class=\"pf-divider\">|<\/span>\n    <a href=\"?page_id=2512\">PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/a><span class=\"pf-divider\">|<\/span>\n    <a href=\"?page_id=2543\">\u5c0a\u777f\u522b\u5885\u8be6\u60c5\u9875<\/a><span class=\"pf-divider\">|<\/span>\n    <a href=\"?page_id=1811\">\u5c0a\u777f\u5168\u6548\u2161\u8be6\u60c5\u9875<\/a><span class=\"pf-divider\">|<\/span>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\">3D\u98ce\u53e3\u8be6\u60c5\u9875<\/a><span class=\"pf-divider\">|<\/span>\n    <a href=\"\/\">\u9f99\u8109\u6696\u901a\u9996\u9875<\/a><span class=\"pf-divider\">|<\/span>\n    <a href=\"?page_id=3011\">\u7ad9\u70b9\u5730\u56fe<\/a>\n  <\/div>\n  <div class=\"pf-bottom\">\n    \u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u8be6\u60c5\u9875 \u00b7 \u9f99\u8109\u6696\u901a\u8865\u5145\u9875\u9762<br>\n    \u7f16\u5236\u5355\u4f4d\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u8d44\u6599\u6765\u6e90\u7f16\u53f7\uff1aHHEXSX202507ZD<br>\n    \u514d\u8d23\u58f0\u660e\uff1a\u4ea7\u54c1\u53c2\u6570\u4f1a\u56e0\u6280\u672f\u6539\u8fdb\u800c\u53d8\u66f4\uff0c\u4ee5\u5b9e\u9645\u4ea7\u54c1\u4e3a\u51c6<br>\n    \u00a9 \u9f99\u8109\u6696\u901a 2004-2026 | \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 | <a href=\"https:\/\/beian.miit.gov.cn\/\">\u8700ICP\u59072026015986\u53f7<\/a>\n  <\/div>\n<\/footer>\n\n<!-- ===== JavaScript ===== -->\n<script>\n(function(){\n  \/* ---- Progress Bar ---- *\/\n  const progressBar = document.getElementById('progressBar');\n  window.addEventListener('scroll', () => {\n    const scrollTop = window.scrollY;\n    const docHeight = document.body.scrollHeight - window.innerHeight;\n    const progress = docHeight > 0 ? (scrollTop \/ docHeight) * 100 : 0;\n    progressBar.style.width = Math.min(progress, 100) + '%';\n  });\n\n  \/* ---- Smart Slider: IntersectionObserver ---- *\/\n  const sections = document.querySelectorAll('.sec');\n  const navItems = document.querySelectorAll('.ni');\n  \n  function updateActiveNav() {\n    let currentId = '';\n    sections.forEach(s => {\n      const rect = s.getBoundingClientRect();\n      if (rect.top <= 140) currentId = s.id;\n    });\n    navItems.forEach(ni => {\n      const isActive = ni.dataset.target === currentId;\n      ni.classList.toggle('active', isActive);\n    });\n  }\n\n  const observer = new IntersectionObserver(entries => {\n    entries.forEach(e => {\n      if (e.isIntersecting) {\n        navItems.forEach(ni => {\n          ni.classList.toggle('active', ni.dataset.target === e.target.id);\n        });\n      }\n    });\n  }, { rootMargin: '-20% 0px -70% 0px', threshold: 0 });\n\n  sections.forEach(s => observer.observe(s));\n\n  \/* ---- Click Navigation ---- *\/\n  navItems.forEach(ni => {\n    ni.addEventListener('click', () => {\n      const target = document.getElementById(ni.dataset.target);\n      if (target) {\n        target.scrollIntoView({ behavior: 'smooth', block: 'start' });\n        \/\/ Close mobile sidebar if open\n        document.getElementById('sidebarToc').classList.remove('open');\n      }\n    });\n  });\n\n  \/* ---- Scroll fallback ---- *\/\n  let ticking = false;\n  window.addEventListener('scroll', () => {\n    if (!ticking) {\n      requestAnimationFrame(() => {\n        updateActiveNav();\n        ticking = false;\n      });\n      ticking = true;\n    }\n  });\n\n  \/\/ Initial highlight\n  updateActiveNav();\n\n  \/* ---- Mobile TOC Toggle ---- *\/\n  const mobToggle = document.getElementById('mobTocToggle');\n  const sidebar = document.getElementById('sidebarToc');\n  mobToggle.addEventListener('click', () => {\n    sidebar.classList.toggle('open');\n  });\n\n  \/\/ Close sidebar when clicking outside on mobile\n  document.addEventListener('click', (e) => {\n    if (window.innerWidth <= 960 && \n        !sidebar.contains(e.target) && \n        e.target !== mobToggle &&\n        !mobToggle.contains(e.target)) {\n      sidebar.classList.remove('open');\n    }\n  });\n\n  \/* ---- FAQ Accordion ---- *\/\n  window.toggleFaq = function(el) {\n    const allQ = document.querySelectorAll('.faq-q');\n    allQ.forEach(q => {\n      if (q !== el) q.classList.remove('open');\n    });\n    el.classList.toggle('open');\n  };\n\n  \/* ---- Collapse Toggle ---- *\/\n  window.toggleCollapse = function(btn) {\n    const wrap = btn.nextElementSibling;\n    const isOpen = btn.classList.contains('open');\n    if (isOpen) {\n      btn.classList.remove('open');\n      wrap.classList.add('collapsed');\n      btn.innerHTML = btn.innerHTML.replace('\u6536\u8d77', '\u5c55\u5f00');\n    } else {\n      btn.classList.add('open');\n      wrap.classList.remove('collapsed');\n      btn.innerHTML = btn.innerHTML.replace('\u5c55\u5f00', '\u6536\u8d77');\n    }\n  };\n\n  \/* ---- Tech Grid Expand ---- *\/\n  window.toggleTechGrid = function(btn) {\n    const grid = btn.previousElementSibling;\n    const cards = grid.querySelectorAll('.tech-card');\n    const isOpen = btn.classList.contains('open');\n    if (isOpen) {\n      btn.classList.remove('open');\n      btn.innerHTML = btn.innerHTML.replace('\u6536\u8d77\u5168\u90e8', '\u5c55\u5f00\u5168\u90e8\u6280\u672f');\n      for (let i = 3; i < cards.length; i++) {\n        cards[i].classList.remove('tech-show');\n        cards[i].classList.add('tech-hidden');\n      }\n    } else {\n      btn.classList.add('open');\n      btn.innerHTML = btn.innerHTML.replace('\u5c55\u5f00\u5168\u90e8\u6280\u672f', '\u6536\u8d77\u5168\u90e8');\n      for (let i = 3; i < cards.length; i++) {\n        cards[i].classList.remove('tech-hidden');\n        cards[i].classList.add('tech-show');\n      }\n    }\n  };\n\n  \/\/ Init: hide tech cards 4-6 on load\n  (function initTechGrid() {\n    const grid = document.querySelector('.tech-grid');\n    if (!grid) return;\n    const cards = grid.querySelectorAll('.tech-card');\n    for (let i = 3; i < cards.length; i++) {\n      cards[i].classList.add('tech-hidden');\n    }\n    \/\/ Add expand button if not already present\n    if (!grid.nextElementSibling || !grid.nextElementSibling.classList.contains('tech-expand-btn')) {\n      const btn = document.createElement('button');\n      btn.className = 'tech-expand-btn';\n      btn.innerHTML = '\u5c55\u5f00\u5168\u90e8\u6280\u672f <span class=\"te-arrow\">\u25bc<\/span>';\n      btn.onclick = function() { toggleTechGrid(this); };\n      grid.insertAdjacentElement('afterend', btn);\n    }\n  })();\n\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u98ce\u624718 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2782","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u53cc\u98ce\u6247\u7cfb\u5217\uff0c180\/200\/224\u578b\uff0c\u9002\u914d140-200\u33a1\u5927\u5e73\u5c42\/\u590d\u5f0f\u3002\u4e00\u62d6\u4e5d\u81f3\u4e00\u62d6\u5341\u4e8c\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c52\u2103\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c\u53cc\u98ce\u6247320mm\u7d27\u51d1\u673a\u8eab\u3002\u9644\u6838\u5fc3\u53c2\u6570\u3001\u9009\u578b\u5bf9\u7167\u3001\u8d85\u914d\u7387\u5efa\u8bae\u3002\u9f99\u8109\u6696\u901a\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2782\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u53cc\u98ce\u6247\u7cfb\u5217\uff0c180\/200\/224\u578b\uff0c\u9002\u914d140-200\u33a1\u5927\u5e73\u5c42\/\u590d\u5f0f\u3002\u4e00\u62d6\u4e5d\u81f3\u4e00\u62d6\u5341\u4e8c\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c52\u2103\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c\u53cc\u98ce\u6247320mm\u7d27\u51d1\u673a\u8eab\u3002\u9644\u6838\u5fc3\u53c2\u6570\u3001\u9009\u578b\u5bf9\u7167\u3001\u8d85\u914d\u7387\u5efa\u8bae\u3002\u9f99\u8109\u6696\u901a\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2782\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-10T07:05:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782\",\"name\":\"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p09-09.jpeg\",\"datePublished\":\"2026-06-09T14:45:33+00:00\",\"dateModified\":\"2026-10-10T07:05:37+00:00\",\"description\":\"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u53cc\u98ce\u6247\u7cfb\u5217\uff0c180\\\/200\\\/224\u578b\uff0c\u9002\u914d140-200\u33a1\u5927\u5e73\u5c42\\\/\u590d\u5f0f\u3002\u4e00\u62d6\u4e5d\u81f3\u4e00\u62d6\u5341\u4e8c\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c52\u2103\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c\u53cc\u98ce\u6247320mm\u7d27\u51d1\u673a\u8eab\u3002\u9644\u6838\u5fc3\u53c2\u6570\u3001\u9009\u578b\u5bf9\u7167\u3001\u8d85\u914d\u7387\u5efa\u8bae\u3002\u9f99\u8109\u6696\u901a\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p09-09.jpeg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p09-09.jpeg\",\"width\":451,\"height\":392},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2782#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217 - \u9f99\u8109\u6696\u901a","description":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u53cc\u98ce\u6247\u7cfb\u5217\uff0c180\/200\/224\u578b\uff0c\u9002\u914d140-200\u33a1\u5927\u5e73\u5c42\/\u590d\u5f0f\u3002\u4e00\u62d6\u4e5d\u81f3\u4e00\u62d6\u5341\u4e8c\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c52\u2103\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c\u53cc\u98ce\u6247320mm\u7d27\u51d1\u673a\u8eab\u3002\u9644\u6838\u5fc3\u53c2\u6570\u3001\u9009\u578b\u5bf9\u7167\u3001\u8d85\u914d\u7387\u5efa\u8bae\u3002\u9f99\u8109\u6696\u901a\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2782","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217 - \u9f99\u8109\u6696\u901a","og_description":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u53cc\u98ce\u6247\u7cfb\u5217\uff0c180\/200\/224\u578b\uff0c\u9002\u914d140-200\u33a1\u5927\u5e73\u5c42\/\u590d\u5f0f\u3002\u4e00\u62d6\u4e5d\u81f3\u4e00\u62d6\u5341\u4e8c\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c52\u2103\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c\u53cc\u98ce\u6247320mm\u7d27\u51d1\u673a\u8eab\u3002\u9644\u6838\u5fc3\u53c2\u6570\u3001\u9009\u578b\u5bf9\u7167\u3001\u8d85\u914d\u7387\u5efa\u8bae\u3002\u9f99\u8109\u6696\u901a\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=2782","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-10T07:05:37+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"10 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2782","url":"https:\/\/longmai-nt.com\/?page_id=2782","name":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=2782#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=2782#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg","datePublished":"2026-06-09T14:45:33+00:00","dateModified":"2026-10-10T07:05:37+00:00","description":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u53cc\u98ce\u6247\u7cfb\u5217\uff0c180\/200\/224\u578b\uff0c\u9002\u914d140-200\u33a1\u5927\u5e73\u5c42\/\u590d\u5f0f\u3002\u4e00\u62d6\u4e5d\u81f3\u4e00\u62d6\u5341\u4e8c\uff0cAPF\u6700\u9ad85.05\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c52\u2103\u9ad8\u6e29\u7a33\u5b9a\u5236\u51b7\uff0c\u53cc\u98ce\u6247320mm\u7d27\u51d1\u673a\u8eab\u3002\u9644\u6838\u5fc3\u53c2\u6570\u3001\u9009\u578b\u5bf9\u7167\u3001\u8d85\u914d\u7387\u5efa\u8bae\u3002\u9f99\u8109\u6696\u901a\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2782#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2782"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=2782#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-09.jpeg","width":451,"height":392},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2782#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u65e5\u7acbEX-\u8212\u4eab\u5927\u5bb9\u91cf180~224\u578b\u53cc\u98ce\u6247\u7cfb\u5217"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2782"}],"version-history":[{"count":9,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2782\/revisions"}],"predecessor-version":[{"id":14460,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2782\/revisions\/14460"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}