{"id":2810,"date":"2026-06-10T12:54:06","date_gmt":"2026-06-10T04:54:06","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2810"},"modified":"2026-06-10T12:55:34","modified_gmt":"2026-06-10T04:55:34","slug":"%e8%94%a1%e5%85%88%e7%94%9f%c2%b7%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e7%b3%bb%e5%88%97%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e6%96%b9%e6%a1%88%e6%8a%a5%e5%91%8a%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2810","title":{"rendered":"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\"><\/h1>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u8521\u5148\u751f<br><strong>\u6237\u578b\u6982\u51b5<\/strong>\uff1a\u7ea6110\u33a1\uff0c\u4e09\u5ba4\u4e24\u5385\uff0c\u5e38\u4f4f3\u4eba<br><strong>\u6838\u5fc3\u9700\u6c42<\/strong>\uff1a\u4e2d\u592e\u7a7a\u8c03\uff08\u5236\u51b7\u5236\u70ed\uff09\uff0c\u4e0d\u9700\u8981\u5730\u6696<br><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u4f59\u7231\u82f1<br><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e746\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e00\u6b65\uff1a\u65b9\u6848\u53ef\u884c\u6027\u6838\u67e5<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1.1 \u5185\u673a\u914d\u7f6e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u91cf(kW)<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u5385\u9910\u5385<\/td><td>42\u33a1<\/td><td>90\u578b<\/td><td>9.0<\/td><\/tr><tr><td>\u5165\u6237\u623f\u95f4<\/td><td>8.4\u33a1<\/td><td>18\u578b<\/td><td>1.8<\/td><\/tr><tr><td>2\u623f\u95f4<\/td><td>8.4\u33a1<\/td><td>18\u578b<\/td><td>1.8<\/td><\/tr><tr><td>\u4e3b\u5367<\/td><td>17\u33a1<\/td><td>36\u578b<\/td><td>3.6<\/td><\/tr><tr><td><strong>\u5185\u673a\u603b\u51b7\u91cf<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td><strong>16.2kW<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">1.2 \u8d85\u914d\u7387\u6838\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u5355\u98ce\u6247125<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u53cc\u98ce\u6247125<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5916\u673a\u578b\u53f7<\/strong><\/td><td>RAS-125HRNAQ<\/td><td>RAS-125HRNBQ<\/td><\/tr><tr><td><strong>\u5916\u673a\u5236\u51b7\u91cf<\/strong><\/td><td>12.5 kW<\/td><td>12.5 kW<\/td><\/tr><tr><td><strong>\u5185\u673a\u603b\u51b7\u91cf<\/strong><\/td><td>16.2 kW<\/td><td>16.2 kW<\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>16.2\u00f712.5\u2248<strong>129.6%<\/strong><\/td><td>16.2\u00f712.5\u2248<strong>129.6%<\/strong><\/td><\/tr><tr><td><strong>\u8bbe\u8ba1\u8981\u6c42<\/strong><\/td><td>50%-130%<\/td><td>50%-130%<\/td><\/tr><tr><td><strong>\u53ef\u884c\u6027\u7ed3\u8bba<\/strong><\/td><td>\u2705&nbsp;<strong>\u53ef\u884c<\/strong><\/td><td>\u2705&nbsp;<strong>\u53ef\u884c<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u91cd\u8981\u8bf4\u660e<\/strong>\uff1a\u8d85\u914d\u7387129.6%\uff0c\u975e\u5e38\u63a5\u8fd1\u65e5\u7acb\u89c4\u5b9a\u7684130%\u4e0a\u9650\uff0c\u8bf4\u660e\u8bbe\u8ba1\u5e08\u5df2\u5c06\u5916\u673a\u6f5c\u529b\u7528\u5230\u6781\u81f4\u3002\u5728\u6781\u7aef\u5929\u6c14\uff08\u5982\u6210\u90fd\u76db\u590f\u6700\u70ed\u7684\u51e0\u5929\uff09\u4e14\u5168\u5c4b4\u53f0\u7a7a\u8c03\u540c\u65f6\u5f00\u542f\u7684\u60c5\u51b5\u4e0b\uff0c\u53ef\u80fd\u4f1a\u51fa\u73b0\u964d\u6e29\u901f\u5ea6\u7a0d\u6162\u7684\u60c5\u51b5\u3002\u4f46\u5bf9\u4e8e\u60a8\u5bb6\u5e38\u4f4f3\u4eba\u3001\u540c\u5f00\u7387\u4f4e\u7684\u60c5\u51b5\uff0c\u65e5\u5e38\u4f7f\u7528\u4e2d\uff08\u4ec5\u5f001-2\u53f0\uff09\u6548\u7387\u53cd\u800c\u66f4\u9ad8\u3002<\/p>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u60f3\u4e86\u89e3\u66f4\u591a\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4fe1\u606f\uff1f<\/strong>&nbsp;<a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" rel=\"noreferrer noopener\">\u70b9\u51fb\u67e5\u770b\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\u624b\u518c<\/a>\uff08\u542b\u5168\u7cfb\u5217\u5916\u673a\u53c2\u6570\u3001\u5185\u673a\u578b\u53f7\u3001\u6838\u5fc3\u4e13\u5229\u6280\u672f\u8be6\u89e3\u3001\u9009\u578b\u6307\u5357\uff09<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e8c\u6b65\uff1a\u8212\u4eab125\u5916\u673a\u6027\u80fd\u5bf9\u6bd4<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">2.1 \u5355\u98ce\u6247 vs \u53cc\u98ce\u6247 \u6838\u5fc3\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u5355\u98ce\u6247125<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u53cc\u98ce\u6247125<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5dee\u5f02\u5206\u6790<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5916\u673a\u578b\u53f7<\/strong><\/td><td>RAS-125HRNAQ<\/td><td>RAS-125HRNBQ<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u5236\u51b7\u91cf<\/strong><\/td><td>12.5 kW<\/td><td>12.5 kW<\/td><td>\u76f8\u540c<\/td><\/tr><tr><td><strong>\u5236\u70ed\u91cf<\/strong><\/td><td>14.0 kW<\/td><td>14.0 kW<\/td><td>\u76f8\u540c<\/td><\/tr><tr><td><strong>APF\u80fd\u6548<\/strong><\/td><td>5.90<\/td><td><strong>6.10<\/strong><\/td><td>\u53cc\u98ce\u6247\u66f4\u7701\u7535<\/td><\/tr><tr><td><strong>\u8fd0\u884c\u8303\u56f4(\u5236\u70ed)<\/strong><\/td><td>-21\u2103 WB<\/td><td><strong>-23\u2103 WB<\/strong><\/td><td>\u53cc\u98ce\u6247\u4f4e\u6e29\u5236\u70ed\u80fd\u529b\u66f4\u5f3a<\/td><\/tr><tr><td><strong>\u8fd0\u884c\u566a\u97f3<\/strong><\/td><td>54 dB(A)<\/td><td><strong>52 dB(A)<\/strong><\/td><td>\u53cc\u98ce\u6247\u66f4\u5b89\u9759<\/td><\/tr><tr><td><strong>\u98ce\u6247\u98ce\u91cf<\/strong><\/td><td>75 m\u00b3\/min<\/td><td><strong>88 m\u00b3\/min<\/strong><\/td><td>\u53cc\u98ce\u6247\u6563\u70ed\u66f4\u597d\uff0c\u9ad8\u8d1f\u8377\u66f4\u7a33\u5b9a<\/td><\/tr><tr><td><strong>\u5916\u673a\u5c3a\u5bf8(\u9ad8\u00d7\u5bbd\u00d7\u539a)<\/strong><\/td><td>770\u00d7980\u00d7360mm<\/td><td>1380\u00d7950\u00d7320mm<\/td><td>\u5355\u98ce\u6247\u66f4\u5c0f\u5de7\uff0c\u53cc\u98ce\u6247\u9700\u66f4\u5927\u7a7a\u95f4<\/td><\/tr><tr><td><strong>\u51c0\u91cd<\/strong><\/td><td>64 kg<\/td><td>106 kg<\/td><td>\u53cc\u98ce\u6247\u7528\u6599\u66f4\u624e\u5b9e<\/td><\/tr><tr><td><strong>\u53cd\u8f6c\u9664\u5c18<\/strong><\/td><td>\u2705 \u6807\u914d<\/td><td>\u2705 \u6807\u914d<\/td><td>\u4e24\u8005\u5747\u6709<\/td><\/tr><tr><td><strong>\u516d\u8109\u6ce2\u52a0\u70ed<\/strong><\/td><td>\u2705 \u6807\u914d<\/td><td>\u2705 \u6807\u914d<\/td><td>\u4e24\u8005\u5747\u6709<\/td><\/tr><tr><td><strong>\u4ef7\u683c\u5dee\u5f02<\/strong><\/td><td>\u57fa\u51c6\uff08\u7ea62.2\u81f32.5\u4e07\uff09<\/td><td><strong>+\u7ea62,500\u5143<\/strong><\/td><td>\u53cc\u98ce\u6247\u6027\u80fd\u66f4\u597d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2.2 \u9009\u578b\u5efa\u8bae<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u5bb6\u60c5\u51b5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7406\u7531<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673a\u4f4d<strong>\u5bbd\u5ea6\u4e0d\u8db31\u7c73<\/strong><\/td><td><strong>\u8212\u4eab125\u5355\u98ce\u6247<\/strong><\/td><td>\u53cc\u98ce\u6247\u5bbd\u5ea6950mm\uff0c\u5355\u98ce\u6247\u662f\u552f\u4e00\u80fd\u88c5\u8fdb\u53bb\u7684\u9009\u62e9<\/td><\/tr><tr><td>\u5916\u673a\u4f4d<strong>\u5bbd\u5ea6\u22651.2\u7c73<\/strong>\uff0c\u8ffd\u6c42\u66f4\u9ad8\u80fd\u6548\u548c\u7a33\u5b9a\u6027<\/td><td><strong>\u8212\u4eab125\u53cc\u98ce\u6247<\/strong><\/td><td>\u80fd\u6548\u66f4\u9ad8\uff086.10 vs 5.90\uff09\u3001\u566a\u97f3\u66f4\u4f4e\uff0852dB vs 54dB\uff09\u3001\u6563\u70ed\u66f4\u5f3a\uff0c\u5bf9129.6%\u8d85\u914d\u7387\u7684\u9ad8\u8d1f\u8377\u573a\u666f\u66f4\u7a33\u5b9a<\/td><\/tr><tr><td><strong>\u9884\u7b97\u4f18\u5148<\/strong><\/td><td><strong>\u8212\u4eab125\u5355\u98ce\u6247<\/strong><\/td><td>\u5355\u98ce\u6247\u4fbf\u5b9c\u7ea62,500\u5143\uff0c\u6027\u80fd\u5b8c\u5168\u591f\u7528<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e09\u6b65\uff1a\u8212\u4eab\u7cfb\u5217\u6838\u5fc3\u6280\u672f\u8be6\u89e3<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e00\u3001\u5ba4\u5185\u673a\uff1a\u667a\u80fd\u81ea\u6e05\u6d01\u4e13\u5229\u6280\u672f + 60\u2103\u9ad8\u6e29\u6740\u83cc<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u662f\u65e5\u7acb\u7684\u6838\u5fc3\u4e13\u5229\u6280\u672f\uff0c\u89e3\u51b3\u4e86\u201c\u7a7a\u8c03\u5439\u51fa\u9709\u5473\u3001\u8981\u8bf7\u4eba\u6d17\u201d\u7684\u884c\u4e1a\u75db\u70b9\u3002<\/strong><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u6280\u672f\u539f\u7406\uff08\u56db\u6b65\u6cd5\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6b65\u9aa4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u4f5c\u539f\u7406<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6548\u679c<\/th><\/tr><\/thead><tbody><tr><td><strong>\u7b2c\u4e00\u6b65\uff1a\u7ed3\u51b0<\/strong><\/td><td>\u5236\u51b7\u6a21\u5f0f\u8fd0\u884c\uff0c\u7fc5\u7247\u8868\u9762\u7ed3\u51b0\uff080\u2103\u4ee5\u4e0b\uff09<\/td><td>\u51b0\u5c42\u5305\u88f9\u7070\u5c18\uff0c\u7070\u5c18\u4e0e\u7fc5\u7247\u7269\u7406\u5265\u79bb<\/td><\/tr><tr><td><strong>\u7b2c\u4e8c\u6b65\uff1a\u5265\u79bb<\/strong><\/td><td>\u51b0\u5c42\u81a8\u80c0\u529b\u4f7f\u7070\u5c18\u4e0e\u7fc5\u7247\u5206\u79bb<\/td><td>\u65e0\u9700\u5316\u5b66\u6e05\u6d17\u5242\uff0c\u7269\u7406\u5265\u79bb\u66f4\u5f7b\u5e95<\/td><\/tr><tr><td><strong>\u7b2c\u4e09\u6b65\uff1a\u878d\u51b0<\/strong><\/td><td>\u5feb\u901f\u5236\u70ed\u878d\u51b0<\/td><td>\u51b0\u878d\u5316\u5e26\u8d70\u7070\u5c18\uff0c\u987a\u6392\u6c34\u7ba1\u6392\u51fa<\/td><\/tr><tr><td><strong>\u7b2c\u56db\u6b65\uff1a\u9ad8\u6e29\u6740\u83cc<\/strong><\/td><td>60\u2103\u9ad8\u6e29\u8fd0\u884c30\u5206\u949f<\/td><td>\u6740\u706d\u7ec6\u83cc\u3001\u75c5\u6bd2\uff0c\u51fa\u98ce\u65e0\u5f02\u5473<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u5ba2\u6237\u4ef7\u503c<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u75db\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u81ea\u6e05\u6d01\u5982\u4f55\u89e3\u51b3<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u5f00\u7a7a\u8c03\u6709\u9709\u5473\u201d<\/td><td>60\u2103\u9ad8\u6e29\u6740\u83cc\uff0c\u5f7b\u5e95\u6740\u706d\u7ec6\u83cc\u9709\u83cc\uff0c\u51fa\u98ce\u6e05\u65b0<\/td><\/tr><tr><td>\u201c\u6bcf\u5e74\u8981\u8bf7\u4eba\u6d17\u7a7a\u8c03\uff0c\u9ebb\u70e6\u53c8\u82b1\u94b1\u201d<\/td><td>\u4e00\u952e\u542f\u52a8\uff0c\u7a7a\u8c03\u81ea\u5df1\u6d17\uff0c\u7701\u53bb\u6bcf\u5e74\u51e0\u767e\u5143\u6e05\u6d17\u8d39<\/td><\/tr><tr><td>\u201c\u7fc5\u7247\u7f1d\u9699\u91cc\u7684\u7070\u5c18\u6d17\u4e0d\u5e72\u51c0\u201d<\/td><td>\u7ed3\u51b0\u7269\u7406\u5265\u79bb\uff0c\u6bd4\u6c34\u51b2\u66f4\u5f7b\u5e95<\/td><\/tr><tr><td>\u201c\u62c5\u5fc3\u6e05\u6d17\u5242\u5316\u5b66\u6b8b\u7559\u201d<\/td><td>\u7eaf\u7269\u7406\u65b9\u5f0f\uff0c\u65e0\u5316\u5b66\u6b8b\u7559<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udcac&nbsp;<strong>\u6548\u679c\u9a8c\u8bc1<\/strong>\uff1a\u201c\u60a8\u518d\u4e5f\u4e0d\u7528\u62c5\u5fc3\u2018\u5f00\u7a7a\u8c03\u6709\u9709\u5473\u2019\u4e86\u3002\u6bcf\u5e74\u6362\u5b63\u65f6\u6309\u4e00\u4e0b\u81ea\u6e05\u6d01\uff0c\u7fc5\u7247\u4e0a\u7684\u7070\u7ed3\u51b0\u5265\u79bb\u3001\u878d\u5316\u51b2\u8d70\uff0c\u518d60\u5ea6\u9ad8\u6e29\u6740\u83cc\u3002\u5439\u51fa\u6765\u7684\u98ce\u6bd4\u5916\u9762\u8fd8\u6e05\u65b0\uff0c\u4e0d\u7528\u8bf7\u4eba\u3001\u4e0d\u7528\u82b1\u94b1\u3002\u201d<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e8c\u3001\u5ba4\u5916\u673a\uff1a\u53cd\u8f6c\u9664\u5c18\u6280\u672f<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5de5\u4f5c\u539f\u7406<\/strong><\/td><td>\u5173\u673a\u540e\u98ce\u673a\u81ea\u52a8\u53cd\u8f6c\uff0c\u5c06\u9644\u7740\u5728\u7fc5\u7247\u4e0a\u7684\u7070\u5c18\u5439\u8d70<\/td><\/tr><tr><td><strong>\u89e6\u53d1\u65b9\u5f0f<\/strong><\/td><td>\u6bcf\u6b21\u5173\u673a\u81ea\u52a8\u8fd0\u884c\uff0c\u65e0\u9700\u4eba\u5de5\u64cd\u4f5c<\/td><\/tr><tr><td><strong>\u6548\u679c<\/strong><\/td><td>\u4fdd\u6301\u5916\u673a\u7fc5\u7247\u6d01\u51c0\uff0c\u6563\u70ed\u6548\u7387\u4e0d\u8870\u51cf<\/td><\/tr><tr><td><strong>\u5ba2\u6237\u4ef7\u503c<\/strong><\/td><td>\u5916\u673a\u4e0d\u7528\u8bf7\u4eba\u6d17\uff0c\u5e38\u5e74\u4fdd\u6301\u9ad8\u6548\u6563\u70ed\uff0c\u7701\u7535\u53c8\u7a33\u5b9a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udcac&nbsp;<strong>\u6548\u679c\u9a8c\u8bc1<\/strong>\uff1a\u201c\u5916\u673a\u4e0d\u7528\u60a8\u64cd\u5fc3\u3002\u6bcf\u6b21\u5173\u673a\uff0c\u98ce\u6247\u81ea\u52a8\u53cd\u8f6c\uff0c\u628a\u7fc5\u7247\u4e0a\u7684\u7070\u5439\u6389\u3002\u5916\u673a\u5e72\u51c0\uff0c\u5236\u51b7\u5c31\u5feb\uff0c\u8fd8\u4e0d\u8d39\u7535\u3002\u201d<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e09\u3001\u8212\u4eab\u5185\u673a\u5b8c\u6574\u529f\u80fd\u6e05\u5355\uff08\u5168\u7cfb\u6807\u914d\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u60a8\u7684\u4ec0\u4e48\u75db\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ef7\u503c<\/th><\/tr><\/thead><tbody><tr><td><strong>\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc<\/strong><\/td><td>\u7a7a\u8c03\u5439\u51fa\u9709\u5473\u3001\u8981\u8bf7\u4eba\u6d17<\/td><td>\u7a7a\u8c03\u81ea\u5df1\u6d17\u6fa1\uff0c\u51fa\u98ce\u6e05\u65b0\uff0c\u7701\u6e05\u6d17\u8d39<\/td><\/tr><tr><td><strong>\u5916\u673a\u53cd\u8f6c\u9664\u5c18<\/strong><\/td><td>\u5916\u673a\u79ef\u7070\u5f71\u54cd\u5236\u51b7\u3001\u8d39\u7535<\/td><td>\u5916\u673a\u81ea\u52a8\u6e05\u6d01\uff0c\u5e38\u5e74\u9ad8\u6548\u7701\u7535<\/td><\/tr><tr><td><strong>\u8d85\u9759\u97f3\uff0817dB\uff09<\/strong><\/td><td>\u6015\u566a\u97f3\u5f71\u54cd\u7761\u7720<\/td><td>\u6bd4\u7ffb\u4e66\u58f0\u8fd8\u8f7b\uff0c\u7761\u7720\u4e0d\u5435<\/td><\/tr><tr><td><strong>\u6807\u914d\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173<\/strong><\/td><td>\u62c5\u5fc3\u6f0f\u6c34\u6ce1\u9876<\/td><td>\u4e0d\u6ce1\u9876\uff0c\u540a\u9876\u66f4\u81ea\u7531<\/td><\/tr><tr><td><strong>\u8d85\u8584\u673a\u8eab\uff08192mm\uff09<\/strong><\/td><td>\u62c5\u5fc3\u5c42\u9ad8\u538b\u6291<\/td><td>\u5b8c\u7f8e\u9690\u85cf\u4e8e\u540a\u9876<\/td><\/tr><tr><td><strong>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/strong><\/td><td>\u4f4e\u9891\u8282\u80fd<\/td><td>\u65e5\u5e38\u5f001-2\u53f0\u65f6\u975e\u5e38\u7701\u7535<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u60f3\u4e86\u89e3\u66f4\u591a\u8212\u4eab\u7cfb\u5217\u6838\u5fc3\u6280\u672f\u8be6\u60c5\uff1f<\/strong>&nbsp;<a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" rel=\"noreferrer noopener\">\u70b9\u51fb\u67e5\u770b\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\u624b\u518c<\/a>\uff08\u542b\u5bbd\u57df\u8fd0\u884c\u80fd\u529b\u3001\u516d\u8109\u6ce2\u52a0\u70ed\u6280\u672f\u3001\u51b7\u5a92\u788e\u6ce1\u6280\u672f\u3001PE\u51c0\u5316\u6a21\u5757\u8be6\u89e3\uff09<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u56db\u6b65\uff1a\u80fd\u8017\u53c2\u6570\u5bf9\u6bd4\u5206\u6790<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">4.1 \u8ba1\u7b97\u524d\u63d0<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53d6\u503c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u7a7a\u8c03\u9762\u79ef<\/td><td>\u7ea6110\u33a1<\/td><td>\u5b9e\u9645\u4f7f\u7528\u9762\u79ef<\/td><\/tr><tr><td>\u5236\u51b7\u5b63\u8282<\/td><td>120\u5929\/\u5e74<\/td><td>\u6210\u90fd\u590f\u5b63\u7ea64\u4e2a\u6708<\/td><\/tr><tr><td>\u7535\u4ef7<\/td><td>0.5\u5143\/\u5ea6<\/td><td>\u5c45\u6c11\u7528\u7535\u53c2\u8003\u4ef7<\/td><\/tr><tr><td>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/td><td>100W\/\u33a1<\/td><td>\u6309\u56fd\u6807GB 50736-2012<\/td><\/tr><tr><td>\u65e5\u5e38\u4f7f\u7528<\/td><td>\u5f001-2\u53f0<\/td><td>\u60a8\u5bb6\u5e38\u4f4f3\u4eba\uff0c\u540c\u5f00\u7387\u4f4e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.2 \u80fd\u8017\u8ba1\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8ba1\u7b97\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u5355\u98ce\u6247125\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab\u53cc\u98ce\u6247125\u65b9\u6848<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5916\u673aAPF<\/strong><\/td><td>5.90<\/td><td><strong>6.10<\/strong><\/td><\/tr><tr><td><strong>\u4f30\u7b97\u7efc\u5408\u80fd\u6548\u7cfb\u6570<\/strong><\/td><td>\u22485.6<\/td><td>\u22485.8<\/td><\/tr><tr><td><strong>\u6052\u6e29\u65f6\u6574\u673a\u8f93\u5165\u529f\u7387<\/strong><\/td><td>12.5\u00f75.6\u22482.23kW<\/td><td>12.5\u00f75.8\u22482.16kW<\/td><\/tr><tr><td><strong>\u6708\u8017\u7535\u91cf\uff08\u6bcf\u592910\u5c0f\u65f6\uff09<\/strong><\/td><td>2.23\u00d710\u00d730\u2248669\u5ea6<\/td><td>2.16\u00d710\u00d730\u2248648\u5ea6<\/td><\/tr><tr><td><strong>\u6708\u7535\u8d39<\/strong><\/td><td><strong>\u7ea6335\u5143\/\u6708<\/strong><\/td><td><strong>\u7ea6324\u5143\/\u6708<\/strong><\/td><\/tr><tr><td><strong>\u5e74\u5236\u51b7\u7535\u8d39<\/strong><\/td><td><strong>\u7ea61,340\u5143\/\u5e74<\/strong><\/td><td><strong>\u7ea61,296\u5143\/\u5e74<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.3 \u80fd\u8017\u7ed3\u8bba<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ed3\u8bba<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td><strong>\u53cc\u98ce\u6247\u6bcf\u5e74\u7701\u7ea644\u5143<\/strong><\/td><td>\u5dee\u8ddd\u4e0d\u5927\uff0c\u4e24\u8005\u90fd\u7701\u7535<\/td><\/tr><tr><td><strong>\u65e5\u5e38\u4f4e\u9891\u975e\u5e38\u7701\u7535<\/strong><\/td><td>\u8212\u4eab\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u5728\u4f4e\u9891\uff08\u5f001-2\u53f0\uff09<\/td><\/tr><tr><td><strong>\u60a8\u7684\u4f7f\u7528\u4e60\u60ef\u5339\u914d<\/strong><\/td><td>\u5e38\u4f4f3\u4eba\uff0c\u65e5\u5e38\u5f001-2\u53f0\uff0c\u8fd9\u5957\u65b9\u6848\u975e\u5e38\u8282\u80fd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e94\u6b65\uff1a\u56de\u5e94\u60a8\u7684\u987e\u8651<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">5.1 \u5173\u4e8e\u4ef7\u683c\u8d35<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u7684\u987e\u8651<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u7b54<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u4ef7\u683c\u4f1a\u4e0d\u4f1a\u592a\u8d35\uff1f\u201d<\/td><td>\u201c\u8521\u5148\u751f\uff0c\u60a8\u9009\u7684\u8fd9\u5957\u8212\u4eab125\u4e00\u62d6\u56db\uff0c\u539f\u4ef7\u7ea62.8-3\u4e07\uff0c\u73b0\u5728\u6709\u56fd\u8865\u6d3b\u52a8\uff0c\u5230\u624b\u4ef7\u7ea6\u5728<strong>2.2\u4e07-2.5\u4e07\u4e4b\u95f4<\/strong>\uff08\u5355\u98ce\u6247\/\u53cc\u98ce\u6247\u6709\u5dee\u5f02\uff09\u3002\u8fd9\u4e2a\u4ef7\u683c\u5728\u65e5\u7acb\u54c1\u724c\u4e2d\u5c5e\u4e8e\u975e\u5e38\u4eb2\u6c11\uff0c\u6838\u5fc3\u529f\u80fd\uff08\u81ea\u6e05\u6d01\u3001\u9ad8\u6e29\u6740\u83cc\u3001\u53cd\u8f6c\u9664\u5c18\uff09\u4e00\u4e2a\u6ca1\u5c11\uff0c\u7528\u7684\u4e5f\u662f\u65e5\u7acb\u9876\u7ea7\u7684\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c\u6027\u4ef7\u6bd4\u975e\u5e38\u9ad8\u3002\u201d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.2 \u5173\u4e8e\u5b89\u88c5\u670d\u52a1<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u7684\u987e\u8651<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u7b54<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u5b89\u88c5\u4f1a\u4e0d\u4f1a\u6709\u95ee\u9898\uff1f\u201d<\/td><td>\u201c\u60a8\u653e\u5fc3\uff0c\u6211\u4eec\u9f99\u8109\u6696\u901a\u662f<strong>\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/strong>\uff0c\u5b89\u88c5\u5de5\u4eba\u90fd\u662f\u6301\u6709\u2018\u7cbe\u5de5\u7cbe\u5320\u2019\u8bc1\u4e66\u7684\u5e08\u5085\uff0c\u5b89\u88c5\u5de5\u827a\u6709\u516b\u5927\u6807\u51c6\u5316\u6d41\u7a0b\uff08\u6c2e\u6c14\u4fdd\u62a4\u710a\u3001\u771f\u7a7a\u5e72\u71e5\u3001\u6309\u56fe\u65bd\u5de5\u7b49\uff09\uff0c\u6bcf\u9053\u5de5\u5e8f\u90fd\u6709\u9a8c\u6536\u7b7e\u5b57\u5355\u3002\u800c\u4e14\u6211\u4eec\u627f\u8bfa\u9690\u853d\u5de5\u7a0b\uff08\u7ba1\u9053\uff095\u5e74\u8d28\u4fdd\uff0c\u6709\u95ee\u9898\u968f\u65f6\u5904\u7406\uff0c\u4e0d\u4f1a\u627e\u4e0d\u5230\u4eba\u3002\u201d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.3 \u5173\u4e8e\u552e\u540e\u670d\u52a1<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u7684\u987e\u8651<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u7b54<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u552e\u540e\u6709\u6ca1\u6709\u4fdd\u969c\uff1f\u201d<\/td><td>\u201c\u552e\u540e\u670d\u52a1\u60a8\u66f4\u4e0d\u7528\u62c5\u5fc3\u3002\u7b2c\u4e00\uff0c\u65e5\u7acb\u4e3b\u673a\u6574\u673a\u8d28\u4fdd<strong>5\u5e74<\/strong>\uff08\u6d3b\u52a8\u671f\u95f4\u52a0\u5c11\u91cf\u7684\u94b1\u53ef\u5ef6\u4fdd\u81f310\u5e74\u8bbe\u5907\u8d28\u4fdd\uff09\u3002\u7b2c\u4e8c\uff0c\u6211\u4eec\u8fd8\u63d0\u4f9b<strong>\u4f1a\u5458\u5236\u4fdd\u517b\u670d\u52a1<\/strong>\uff08199\u5143\/\u5e74\uff09\uff0c\u5305\u542b\u5e74\u5ea6\u514d\u8d39\u68c0\u6d4b\u3001\u7cfb\u7edf\u7ef4\u62a4\u3001\u7d27\u6025\u62a5\u4fee\u901a\u9053\u7b49\uff0c\u76f8\u5f53\u4e8e\u7ed9\u60a8\u7684\u7a7a\u8c03\u7cfb\u7edf\u4e70\u4e86\u4efd\u2018\u957f\u671f\u4fdd\u9669\u2019\u3002\u6211\u4eec\u9f99\u8109\u6696\u901a\u5728\u6210\u90fd\u505a\u4e8620\u591a\u5e74\uff0c\u9760\u7684\u5c31\u662f\u9ad8\u8d28\u91cf\u5b89\u88c5\u548c\u670d\u52a1\uff0c\u8fd9\u70b9\u8bf7\u653e\u5fc3\u3002\u201d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u516d\u6b65\uff1a\u65b9\u6848\u6c47\u603b<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5916\u673a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8d85\u914d\u7387<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6708\u7535\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u7535\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9884\u4f30\u603b\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td><strong>\u65b9\u6848\u4e00\uff1a\u5355\u98ce\u6247<\/strong><\/td><td>\u8212\u4eab125\u5355\u98ce\u6247<\/td><td>129.6%<\/td><td>\u7ea6335\u5143<\/td><td>\u7ea61,340\u5143<\/td><td><strong>\u7ea62.2\u4e07<\/strong><\/td><td>\u5916\u673a\u4f4d\u5bbd\u5ea6\u4e0d\u8db31\u7c73\uff0c\u9884\u7b97\u4f18\u5148<\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e8c\uff1a\u53cc\u98ce\u6247<\/strong><\/td><td>\u8212\u4eab125\u53cc\u98ce\u6247<\/td><td>129.6%<\/td><td>\u7ea6324\u5143<\/td><td>\u7ea61,296\u5143<\/td><td><strong>\u7ea62.5\u4e07<\/strong><\/td><td>\u5916\u673a\u4f4d\u5bbd\u88d5\uff0c\u8ffd\u6c42\u66f4\u9ad8\u80fd\u6548\u548c\u7a33\u5b9a\u6027<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e03\u6b65\uff1a\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/strong><\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td><strong>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/strong><\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/td><\/tr><tr><td><strong>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/strong><\/td><td>\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6\uff08\u6c2e\u6c14\u4fdd\u62a4\u710a\u3001\u771f\u7a7a\u5e72\u71e5\u3001\u6309\u56fe\u65bd\u5de5\uff09<\/td><\/tr><tr><td><strong>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/strong><\/td><td>\u8bbe\u5907\u8d39+\u5b89\u88c5\u8d39\u5206\u5217\uff0c\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td><strong>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/strong><\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td><strong>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/strong><\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192+\u4f18\u5148\u54cd\u5e94<\/td><\/tr><tr><td><strong>\u5b98\u65b9\u6388\u6743<\/strong><\/td><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c\u516b\u6b65\uff1a\u4e00\u53e5\u8bdd\u603b\u7ed3<\/h2>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8521\u5148\u751f\uff0c\u60a8\u5bb6110\u33a1\u4e09\u5ba4\uff0c\u4e2d\u592e\u7a7a\u8c03\u9009\u8212\u4eab125\u4e00\u62d6\u56db\uff08\u8d85\u914d\u7387129.6%\u5408\u7406\uff0c\u4e3b\u5367\u914d36\u578b\u3001\u5ba2\u9910\u5385\u914d90\u578b\uff09\u3002\u5916\u673a\u4f4d\u5bbd\u5ea6\u8db3\u9009\u53cc\u98ce\u6247\uff08APF6.10\u3001\u566a\u97f352dB\u3001\u6563\u70ed\u66f4\u5f3a\uff09\uff0c\u5916\u673a\u4f4d\u7a84\u9009\u5355\u98ce\u6247\uff08\u4fbf\u5b9c2,500\u5143\uff09\u3002\u6838\u5fc3\u529f\u80fd\u5168\u7cfb\u6807\u914d\uff1a\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\uff08\u81ea\u52a8\u4fdd\u6301\u9ad8\u6548\uff09\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876\u3002\u6708\u7535\u8d39\u7ea6324-335\u5143\uff0c\u603b\u4ef72.2-2.5\u4e07\u3002\u9f99\u8109\u6696\u901a\u5b98\u65b9\u6388\u6743\uff0c\u7cbe\u5de5\u5b89\u88c5\uff0c\u552e\u540e\u65e0\u5fe7\u3002<\/strong><\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u62a5\u544a\u4e66\u7ed3\u675f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u9700\u7cbe\u786e\u62a5\u4ef7\u5355\uff08\u542b\u8bbe\u5907\u660e\u7ec6\u3001\u5b89\u88c5\u8d39\u3001\u8f85\u6750\u8d39\uff09\uff0c\u8bf7\u786e\u8ba4\u65b9\u6848\u65b9\u5411\u548c\u5916\u673a\u4f4d\u5c3a\u5bf8\u540e\uff0c\u6211\u4e3a\u60a8\u51fa\u8be6\u7ec6\u62a5\u4ef7<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\uff0c\u59cb\u4e8e2004\u5e74\uff0c\u9500\u552e\u7ecf\u7406\uff1a\u4f59\u7231\u82f1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8054\u7cfb\u7535\u8bdd\uff1a13908183204<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u95e8\u5e97\u5730\u5740\uff0c\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99862\u53f7\u5e97\u4e09\u697cA-348\u53f7<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\uff1a\u8521\u5148\u751f\u6237\u578b\u6982\u51b5\uff1a\u7ea6110\u33a1\uff0c\u4e09\u5ba4\u4e24 [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2810","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u8521\u5148\u751f110\u33a1\u4e09\u5ba4\uff0c\u8212\u4eab125\u4e00\u62d64\uff0c\u5168\u7cfb\u6807\u914d\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876,\u9f99\u8109\u7cbe\u5de5\u5b89\u88c55\u5e74\u8d28\u4fdd\uff0c\u53ef\u4ee5\u9009\u62e9\u5ef6\u4fdd\u670d\u52a1\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2810\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u8521\u5148\u751f110\u33a1\u4e09\u5ba4\uff0c\u8212\u4eab125\u4e00\u62d64\uff0c\u5168\u7cfb\u6807\u914d\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876,\u9f99\u8109\u7cbe\u5de5\u5b89\u88c55\u5e74\u8d28\u4fdd\uff0c\u53ef\u4ee5\u9009\u62e9\u5ef6\u4fdd\u670d\u52a1\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2810\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-10T04:55:34+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2810\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2810\",\"name\":\"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-10T04:54:06+00:00\",\"dateModified\":\"2026-06-10T04:55:34+00:00\",\"description\":\"\u8521\u5148\u751f110\u33a1\u4e09\u5ba4\uff0c\u8212\u4eab125\u4e00\u62d64\uff0c\u5168\u7cfb\u6807\u914d\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876,\u9f99\u8109\u7cbe\u5de5\u5b89\u88c55\u5e74\u8d28\u4fdd\uff0c\u53ef\u4ee5\u9009\u62e9\u5ef6\u4fdd\u670d\u52a1\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2810#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2810\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2810#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66 - \u9f99\u8109\u6696\u901a","description":"\u8521\u5148\u751f110\u33a1\u4e09\u5ba4\uff0c\u8212\u4eab125\u4e00\u62d64\uff0c\u5168\u7cfb\u6807\u914d\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876,\u9f99\u8109\u7cbe\u5de5\u5b89\u88c55\u5e74\u8d28\u4fdd\uff0c\u53ef\u4ee5\u9009\u62e9\u5ef6\u4fdd\u670d\u52a1","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2810","og_locale":"zh_CN","og_type":"article","og_title":"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u8521\u5148\u751f110\u33a1\u4e09\u5ba4\uff0c\u8212\u4eab125\u4e00\u62d64\uff0c\u5168\u7cfb\u6807\u914d\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876,\u9f99\u8109\u7cbe\u5de5\u5b89\u88c55\u5e74\u8d28\u4fdd\uff0c\u53ef\u4ee5\u9009\u62e9\u5ef6\u4fdd\u670d\u52a1","og_url":"https:\/\/longmai-nt.com\/?page_id=2810","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-10T04:55:34+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2810","url":"https:\/\/longmai-nt.com\/?page_id=2810","name":"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-10T04:54:06+00:00","dateModified":"2026-06-10T04:55:34+00:00","description":"\u8521\u5148\u751f110\u33a1\u4e09\u5ba4\uff0c\u8212\u4eab125\u4e00\u62d64\uff0c\u5168\u7cfb\u6807\u914d\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff08\u81ea\u5df1\u6d17\uff0c\u4e0d\u7528\u8bf7\u4eba\uff09\u3001\u5916\u673a\u53cd\u8f6c\u9664\u5c18\u300117dB\u8d85\u9759\u97f3\u3001\u63d0\u5347\u6cf5\u4e0d\u6ce1\u9876,\u9f99\u8109\u7cbe\u5de5\u5b89\u88c55\u5e74\u8d28\u4fdd\uff0c\u53ef\u4ee5\u9009\u62e9\u5ef6\u4fdd\u670d\u52a1","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2810#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2810"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2810#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u8521\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u62a5\u544a\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2810","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2810"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2810\/revisions"}],"predecessor-version":[{"id":2812,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2810\/revisions\/2812"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2810"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}