{"id":2827,"date":"2026-06-10T15:07:32","date_gmt":"2026-06-10T07:07:32","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2827"},"modified":"2026-06-10T15:07:33","modified_gmt":"2026-06-10T07:07:33","slug":"%e9%be%99%e8%80%81%e5%b8%88%e6%9a%96%e9%80%9a%e6%96%b9%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2827","title":{"rendered":"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66"},"content":{"rendered":"\n\n<style>\n  :root {\n    --primary: #1a3a5c;\n    --accent: #c0392b;\n    --accent-blue: #2980b9;\n    --bg: #f5f5f5;\n    --card: #ffffff;\n    --border: #e0e0e0;\n    --text: #333333;\n  }\n  * { margin:0; padding:0; box-sizing: border-box; }\n  body {\n    font-family: \"Microsoft YaHei\", \"PingFang SC\", \"Helvetica Neue\", sans-serif;\n    background: var(--bg);\n    color: var(--text);\n    line-height: 1.7;\n    font-size: 15px;\n  }\n  .container { max-width: 1100px; margin:0 auto; padding:20px; }\n\n  .header {\n    background: linear-gradient(135deg, #1a3a5c 0%, #2c5f8a 100%);\n    color: #fff;\n    padding: 40px 30px;\n    border-radius: 12px;\n    margin-bottom:30px;\n    text-align: center;\n  }\n  .header .brand { font-size:13px; letter-spacing:4px; opacity:0.8; text-transform:uppercase; margin-bottom:8px; }\n  .header h1 { font-size:28px; font-weight:700; margin-bottom:6px; }\n  .header .subtitle { font-size:15px; opacity:0.85; margin-bottom:16px; }\n  .header .meta {\n    display: flex; justify-content:center; gap:30px; flex-wrap:wrap;\n    font-size:13px; opacity:0.75;\n  }\n\n  .section { background:var(--card); border-radius:10px; padding:28px 30px; margin-bottom:24px; box-shadow:0 2px 8px rgba(0,0,0,0.06); }\n  .section h2 {\n    font-size:20px; color:var(--primary); border-left:4px solid var(--accent);\n    padding-left:14px; margin-bottom:20px;\n  }\n  .section h3 { font-size:16px; color:var(--primary); margin:18px 0 10px; }\n\n  table { width:100%; border-collapse:collapse; margin:12px 0; font-size:14px; }\n  th { background:#f0f4f8; color:var(--primary); font-weight:600; padding:10px 12px; text-align:center; border:1px solid #dde; }\n  td { padding:10px 12px; text-align:center; border:1px solid #e8e8e8; }\n  tr:hover td { background:#fafcfe; }\n  .ta-left { text-align:left; }\n  .ta-right { text-align:right; }\n  .highlight-row td { background:#fffdf0; font-weight:600; }\n  .total-row td { background:#f0f7ff; font-weight:700; font-size:15px; }\n\n  .tag { display:inline-block; padding:3px 10px; border-radius:20px; font-size:12px; font-weight:600; }\n  .tag-red { background:#fde8e8; color:#c0392b; }\n  .tag-blue { background:#e8f0fd; color:#2980b9; }\n  .tag-green { background:#e8f8e8; color:#27ae60; }\n\n  .compare-grid { display:grid; grid-template-columns:1fr 1fr; gap:20px; margin:16px 0; }\n  .compare-card {\n    border-radius:10px; padding:24px; border:2px solid #eee;\n  }\n  .compare-card.scheme-a { border-color:#c0392b; background:#fffaf9; }\n  .compare-card.scheme-b { border-color:#2980b9; background:#f9faff; }\n  .compare-card .card-tag { margin-bottom:12px; }\n  .compare-card .card-price {\n    font-size:32px; font-weight:700; color:#000;\n    margin:10px 0;\n  }\n  .compare-card .card-price small { font-size:14px; color:#999; font-weight:400; }\n\n  .feature-list { list-style:none; padding:0; }\n  .feature-list li { padding:6px 0; padding-left:24px; position:relative; font-size:14px; }\n  .feature-list li::before { content:''; position:absolute; left:0; top:12px; width:8px; height:8px; border-radius:50%; }\n\n  .insight-box {\n    background: #f8f9fa;\n    border-left: 4px solid var(--primary);\n    padding: 16px 20px;\n    margin: 16px 0;\n    border-radius: 0 8px 8px 0;\n    font-size: 14px;\n    line-height: 1.8;\n  }\n  .insight-box h4 {\n    color: var(--primary);\n    margin-bottom: 8px;\n    font-size: 15px;\n  }\n\n  .highlight-box {\n    background: linear-gradient(135deg, #fff9e6 0%, #fff3cd 100%);\n    border: 1px solid #ffd54f;\n    border-radius: 8px;\n    padding: 20px;\n    margin: 16px 0;\n  }\n  .highlight-box h4 {\n    color: #f57c00;\n    margin-bottom: 10px;\n    font-size: 16px;\n  }\n\n  .pros-cons-grid {\n    display: grid;\n    grid-template-columns: 1fr 1fr;\n    gap: 16px;\n    margin: 16px 0;\n  }\n  .pros-box {\n    background: #f0faf0;\n    border: 1px solid #c8e6c9;\n    border-radius: 8px;\n    padding: 16px;\n  }\n  .pros-box h4 { color: #27ae60; margin-bottom: 10px; }\n  .cons-box {\n    background: #fef0f0;\n    border: 1px solid #ffcdd2;\n    border-radius: 8px;\n    padding: 16px;\n  }\n  .cons-box h4 { color: #e74c3c; margin-bottom: 10px; }\n  .pros-box ul, .cons-box ul { list-style:none; padding:0; font-size:14px; }\n  .pros-box li, .cons-box li { padding:4px 0; padding-left:20px; position:relative; }\n  .pros-box li::before { position:absolute; left:0; top:10px; width:6px; height:6px; border-radius:50%; background:#27ae60; content:''; }\n  .cons-box li::before { position:absolute; left:0; top:10px; width:6px; height:6px; border-radius:50%; background:#e74c3c; content:''; }\n\n  .sys-diagram {\n    display: flex;\n    justify-content: center;\n    gap: 30px;\n    margin: 20px 0;\n    flex-wrap: wrap;\n  }\n  .sys-box {\n    border: 2px solid #ccc;\n    border-radius: 10px;\n    padding: 16px 20px;\n    width: 300px;\n    text-align: center;\n  }\n  .sys-box.scheme-a { border-color:#c0392b; }\n  .sys-box.scheme-b { border-color:#2980b9; }\n  .sys-box h4 { margin-bottom:10px; font-size:15px; }\n  .sys-box .sys-item {\n    background:#f5f5f5; border-radius:6px; padding:6px 10px; margin:6px 0; font-size:13px;\n  }\n\n  .notice { background:#fff8e1; border:1px solid #ffe082; border-radius:8px; padding:16px 20px; margin:16px 0; font-size:14px; }\n  .notice strong { color:#e67e22; }\n\n  .ext-link { display:inline-block; color:#2980b9; text-decoration:none; padding:6px 14px; border:1px solid #2980b9; border-radius:20px; font-size:13px; margin:4px; transition:all 0.2s; }\n  .ext-link:hover { background:#2980b9; color:#fff; }\n\n  .footer {\n    background:var(--primary); color:#fff; border-radius:10px; padding:24px 30px;\n    text-align:center; font-size:13px; line-height:2;\n  }\n  .footer a { color:#fff; text-decoration:underline; }\n\n  .badge { display:inline-block; padding:2px 8px; border-radius:4px; font-size:11px; font-weight:600; margin:0 4px; }\n  .badge-red { background:#ffeaea; color:#c0392b; }\n  .badge-blue { background:#eaf0ff; color:#2980b9; }\n\n  .note-line {\n    font-size: 13px;\n    color: #666;\n    margin: 4px 0;\n    padding-left: 16px;\n    position: relative;\n  }\n  .note-line::before {\n    content: \"*\";\n    position: absolute;\n    left: 0;\n    color: #999;\n  }\n\n  .analysis-table th:first-child { width:160px; text-align:left; padding-left:16px; }\n  .analysis-table td:first-child { text-align:left; padding-left:16px; font-weight:500; }\n  .analysis-table .winner { background:#f0fff0; font-weight:600; }\n\n  .divider {\n    height: 1px;\n    background: linear-gradient(to right, transparent, #ddd, transparent);\n    margin: 24px 0;\n  }\n\n  @media (max-width:768px) {\n    .compare-grid { grid-template-columns:1fr; }\n    .pros-cons-grid { grid-template-columns:1fr; }\n    .header h1 { font-size:22px; }\n    table { font-size:12px; }\n    td, th { padding:6px 8px; }\n  }\n<\/style>\n\n<div class=\"container\">\n\n<!-- HEADER -->\n<div class=\"header\">\n  <div class=\"brand\">\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/div>\n  <h1>\u9f99\u8001\u5e08 \u00b7 \u5929\u6c1f\u5730\u6c34 vs \u58c1\u6302\u7089 \u65b9\u6848\u5bf9\u6bd4<\/h1>\n  <div class=\"subtitle\">\u5c0a\u777f\u5168\u6548II 180\u578b\u4e00\u62d6\u516d\u7a7a\u8c03 + \u4e24\u79cd\u91c7\u6696\u65b9\u6848\u5168\u666f\u5206\u6790<\/div>\n  <div class=\"meta\">\n    <span>\u7f16\u53f7\uff1aQ-20260610-LONG-HEAT<\/span>\n    <span>\u62a5\u4ef7\u65e5\u671f\uff1a2026\u5e746\u670810\u65e5<\/span>\n    <span>\u6709\u6548\u671f\uff1a7\u5929<\/span>\n    <span>\u6d3b\u52a8\uff1a618\u6d3b\u52a8\u671f\u5185<\/span>\n  <\/div>\n<\/div>\n\n<!-- \u9879\u76ee\u6982\u51b5 -->\n<div class=\"section\">\n  <h2>\u9879\u76ee\u6982\u51b5\u4e0e\u51b3\u7b56\u56de\u987e<\/h2>\n\n  <div class=\"insight-box\">\n    <h4>\u5ba2\u6237\u51b3\u7b56\u8def\u5f84<\/h4>\n    <p><strong>\u5df2\u9009\u5b9a\uff1a<\/strong>\u4e2d\u592e\u7a7a\u8c03\u91c7\u7528\u65e5\u7acb\u5c0a\u777f\u5168\u6548II\u4e09\u7ba1\u5236\u7cfb\u7edf\uff0c\u4e3b\u673a180\u578b\u4e00\u62d6\u516d\uff0c\u5185\u673a\u914d\u7f6e\u7ecf\u4f18\u5316\u8c03\u6574\u3002<\/p>\n    <p><strong>\u5f85\u51b3\u7b56\uff1a<\/strong>\u91c7\u6696\u7cfb\u7edf \u2014 A\u65b9\u6848\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff08\u52a0160\u6c34\u6a21\u5757\uff09 vs B\u65b9\u6848\u83f2\u65af\u66fcB1JG25\u58c1\u6302\u7089\u3002<\/p>\n  <\/div>\n\n  <table>\n    <tr><td style=\"width:150px; text-align:right; font-weight:500; background:#fafafa;\">\u5efa\u7b51\u9762\u79ef<\/td><td>\u7ea6198 m\u00b2\uff08\u4e24\u5c42\u522b\u5885\uff09<\/td><td style=\"width:150px; text-align:right; font-weight:500; background:#fafafa;\">\u671d\u5411<\/td><td>\u671d\u5357<\/td><\/tr>\n    <tr><td style=\"text-align:right; font-weight:500; background:#fafafa;\">\u7a7a\u8c03\u65b9\u6848<\/td><td colspan=\"3\"><strong>\u5c0a\u777f\u5168\u6548II 180\u578b\u4e00\u62d6\u516d<\/strong>\uff08\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff09<\/td><\/tr>\n    <tr><td style=\"text-align:right; font-weight:500; background:#fafafa;\">\u91c7\u6696\u9762\u79ef<\/td><td><strong>123 m\u00b2<\/strong>\uff08\u5730\u6696\u94fa\u8bbe\u533a\u57df\uff09<\/td><td style=\"text-align:right; font-weight:500; background:#fafafa;\">\u91c7\u6696\u65b9\u5f0f<\/td><td>\u5730\u6696\u8f90\u5c04\u91c7\u6696<\/td><\/tr>\n    <tr><td style=\"text-align:right; font-weight:500; background:#fafafa;\">\u4f7f\u7528\u573a\u666f<\/td><td colspan=\"3\">\u767d\u5929\u5ba2\u9910\u5385\u5168\u5f00 + \u6700\u591a2\u4e2a\u5367\u5ba4\uff1b\u665a\u4e0a\u5367\u5ba4\u5168\u5f00<\/td><\/tr>\n  <\/table>\n\n  <p class=\"note-line\">\u7a7a\u8c03\u65b9\u6848\u8c03\u6574\u8bf4\u660e\uff1a\u4e3b\u673a\u7531160\u578b\u5347\u7ea7\u81f3180\u578b\uff08\u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a\uff09\uff0c\u5ba2\u9910\u5385\u589e\u52a0\u4e00\u53f022\u578b\u8f85\u52a9\u5185\u673a\uff0871+22\u53cc\u5185\u673a\u8986\u76d655\u33a1\uff09\uff0c\u51716\u53f0\u5ba4\u5185\u673a<\/p>\n  <p class=\"note-line\">\u7cfb\u7edf\u603b\u5bb9\u91cf\uff1a71+22+22+56+25+22 = 218\uff0c\u4e3b\u673a180\u578b\uff0c\u8d85\u914d\u7387 218\/180 = 121.1%\uff08\u6c1f\u7cfb\u7edf130%\u5b89\u5168\u8303\u56f4\u5185\uff09<\/p>\n<\/div>\n\n<!-- \u7a7a\u8c03\u914d\u7f6e\uff08\u5171\u7528\u90e8\u5206\uff09 -->\n<div class=\"section\">\n  <h2>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u914d\u7f6e <span class=\"tag tag-red\">\u5171\u7528\u90e8\u5206<\/span><\/h2>\n  <p style=\"color:#666; margin-bottom:16px; font-size:14px;\">\n    \u4ee5\u4e0b\u7a7a\u8c03\u914d\u7f6e\u4e3a\u4e24\u5957\u91c7\u6696\u65b9\u6848\u5171\u7528\uff0c\u8bbe\u5907\u53ca\u5b89\u88c5\u8d39\u5b8c\u5168\u76f8\u540c\u3002\u4e3b\u673a\u9009\u7528\u5c0a\u777f\u5168\u6548II 180\u578b\uff0c\u642d\u8f7d\u5168\u7cfb\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u673a\u3002\n  <\/p>\n\n  <table>\n    <thead>\n      <tr><th>\u4f4d\u7f6e<\/th><th>\u9762\u79ef<\/th><th>\u578b\u53f7<\/th><th>\u89c4\u683c<\/th><th>\u9762\u4ef7(\u5143)<\/th><th>8\u6298\u540e(\u5143)<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u5ba4\u5916\u673a<\/strong><\/td>\n        <td>\u2014<\/td>\n        <td class=\"ta-left\">RAS-180FSXPN5Q<\/td>\n        <td>180\u578b \/ 6\u5339 \/ \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td>\n        <td class=\"ta-right\">24,125<\/td>\n        <td class=\"ta-right\"><strong>19,300<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u5ba2\u9910\u5385\uff08\u4e3b\uff09<\/strong><\/td>\n        <td>55\u33a1<\/td>\n        <td class=\"ta-left\">RPIZ-71FSVN2QB\/PC<\/td>\n        <td>71\u578b \/ 7.1kW \/ \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td class=\"ta-right\">5,825<\/td>\n        <td class=\"ta-right\"><strong>4,660<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u5ba2\u9910\u5385\uff08\u8f85\uff09<\/strong><\/td>\n        <td>55\u33a1<\/td>\n        <td class=\"ta-left\">RPIZ-22FSVN2QB\/PC<\/td>\n        <td>22\u578b \/ 2.2kW \/ \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td class=\"ta-right\">5,050<\/td>\n        <td class=\"ta-right\"><strong>4,040<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u4e00\u697c\u8001\u4eba\u623f<\/td>\n        <td>9.59\u33a1<\/td>\n        <td class=\"ta-left\">RPIZ-22FSVN2QB\/PC<\/td>\n        <td>22\u578b \/ 2.2kW \/ \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td class=\"ta-right\">5,050<\/td>\n        <td class=\"ta-right\"><strong>4,040<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u4e8c\u697c\u4e3b\u5367<\/td>\n        <td>37\u33a1<\/td>\n        <td class=\"ta-left\">RPIZ-56FSVN2QB\/PC<\/td>\n        <td>56\u578b \/ 5.6kW \/ \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td class=\"ta-right\">5,663<\/td>\n        <td class=\"ta-right\"><strong>4,530<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u4e8c\u697c\u6b21\u53671<\/td>\n        <td>15.7\u33a1<\/td>\n        <td class=\"ta-left\">RPIZ-25FSVN2QB\/PC<\/td>\n        <td>25\u578b \/ 2.5kW \/ \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td class=\"ta-right\">5,050<\/td>\n        <td class=\"ta-right\"><strong>4,040<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u4e8c\u697c\u6b21\u53672<\/td>\n        <td>9\u33a1<\/td>\n        <td class=\"ta-left\">RPIZ-22FSVN2QB\/PC<\/td>\n        <td>22\u578b \/ 2.2kW \/ \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td class=\"ta-right\">5,050<\/td>\n        <td class=\"ta-right\"><strong>4,040<\/strong><\/td>\n      <\/tr>\n      <tr class=\"highlight-row\">\n        <td colspan=\"4\" class=\"ta-left\"><strong>\u7a7a\u8c03\u8bbe\u5907\u5408\u8ba1\uff081\u5916\u673a + 6\u5185\u673a\uff09<\/strong><\/td>\n        <td class=\"ta-right\"><strong>55,813<\/strong><\/td>\n        <td class=\"ta-right\"><strong>44,650<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/strong><\/td>\n        <td>\u2014<\/td>\n        <td class=\"ta-left\">PC-P1HPQA<\/td>\n        <td>6\u4e2a\uff08\u5ba2\u9910\u5385\/\u8001\u4eba\u623f\/\u4e3b\u5367\/\u6b21\u53671\/\u6b21\u53672\uff09<\/td>\n        <td class=\"ta-right\">2,856<\/td>\n        <td class=\"ta-right\"><strong>2,285<\/strong><\/td>\n      <\/tr>\n      <tr class=\"highlight-row\">\n        <td colspan=\"4\" class=\"ta-left\"><strong>\u7a7a\u8c03\u8bbe\u5907\u603b\u8ba1\uff08\u542b\u7ebf\u63a7\u5668\uff09<\/strong><\/td>\n        <td class=\"ta-right\"><strong>58,669<\/strong><\/td>\n        <td class=\"ta-right\"><strong>46,935<\/strong><\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n  <p class=\"note-line\">\u9762\u4ef7\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee4\u5e93 V5.0\uff082026.05.23\uff09\uff0c\u5c0a\u777f\u7cfb\u5217\u7533\u8bf78\u6298\u4f18\u60e0<\/p>\n  <p class=\"note-line\">\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668\uff08PC-P1HPQA\uff0c476\u5143\/\u4e2a\u00d76\u4e2a\uff0c8\u6298\uff09\u5b89\u88c5\u8d39\u6807\u6ce8\"\u2014\"\uff0c\u5df2\u542b\u5728\u9762\u4ef7\u5185\uff0c\u4e0d\u989d\u5916\u6536\u53d6<\/p>\n  <p class=\"note-line\">\u6240\u6709\u5185\u673a\u6807\u914d\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 + PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757 + \u81ea\u6e05\u6d01\u9ad8\u6e29\u6740\u83cc<\/p>\n\n  <h3>\u7a7a\u8c03\u7cfb\u7edf\u5b89\u88c5\u8d39<\/h3>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td class=\"ta-left\">\u5916\u673a\u5b89\u88c5\u8d39<\/td><td>1\u53f0<\/td><td class=\"ta-right\">600 \u5143\/\u53f0<\/td><td class=\"ta-right\">600<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\u8d39\uff08\u542b\u94dc\u7ba1\/\u4fdd\u6e29\/\u98ce\u53e3\uff09<\/td><td>6\u53f0<\/td><td class=\"ta-right\">1,900 \u5143\/\u53f0<\/td><td class=\"ta-right\">11,400<\/td><\/tr>\n      <tr class=\"highlight-row\"><td colspan=\"3\" class=\"ta-left\"><strong>\u7a7a\u8c03\u5b89\u88c5\u8d39\u5c0f\u8ba1<\/strong><\/td><td class=\"ta-right\"><strong>12,000<\/strong><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3>\u7a7a\u8c03\u7cfb\u7edf\u8d39\u7528\u5c0f\u7ed3<\/h3>\n  <table>\n    <tbody>\n      <tr><td class=\"ta-left\" style=\"width:200px;\">\u7a7a\u8c03\u8bbe\u5907\u6298\u540e\u4ef7\uff08\u542b6\u4e2a\u7ebf\u63a7\u5668\uff09<\/td><td class=\"ta-right\">46,935<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u7a7a\u8c03\u5b89\u88c5\u8d39<\/td><td class=\"ta-right\">12,000<\/td><\/tr>\n      <tr class=\"highlight-row\"><td class=\"ta-left\">\u7a7a\u8c03\u7cfb\u7edf\u5c0f\u8ba1<\/td><td class=\"ta-right\" style=\"font-size:16px;\">58,935<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"notice\" style=\"margin-top:16px;\">\n    <strong>\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u7a7a\u8c03\u7cfb\u7edf\u8d39\u7528\u5728\u4e24\u5957\u91c7\u6696\u65b9\u6848\u4e2d<strong>\u5b8c\u5168\u76f8\u540c<\/strong>\u3002\u4ee5\u4e0b\u4ec5\u5bf9\u91c7\u6696\u90e8\u5206\u8fdb\u884c\u5bf9\u6bd4\u5206\u6790\u3002\n  <\/div>\n<\/div>\n\n<!-- \u65b9\u6848\u4e00\uff1a\u5929\u6c1f\u5730\u6c34 -->\n<div class=\"section\">\n  <h2>\u65b9\u6848\u4e00\uff1a\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b <span class=\"tag tag-red\">\u5c0a\u777f + 160\u6c34\u6a21\u5757<\/span><\/h2>\n  <p style=\"color:#666; margin-bottom:16px; font-size:14px;\">\n    \u5728\u5c0a\u777f\u5168\u6548II\u7a7a\u8c03\u7cfb\u7edf\u57fa\u7840\u4e0a\uff0c\u589e\u52a0160\u578b\u5916\u7f6e\u6c34\u6a21\u5757\uff08RWMG-160FWXNZQ\uff09\uff0c\u5b9e\u73b0\u7a7a\u8c03\u5236\u51b7 + \u5730\u6696\u91c7\u6696\u4e8c\u8054\u4f9b\u3002<strong>\u4e00\u5957\u4e3b\u673a\u540c\u65f6\u9a71\u52a8\u7a7a\u8c03\u548c\u5730\u6696<\/strong>\uff0c\u51ac\u5b63\u901a\u8fc7\u6c34\u6a21\u5757\u5c06\u70ed\u91cf\u4f20\u9012\u7ed9\u5730\u6696\u6c34\u7cfb\u7edf\u3002\n  <\/p>\n\n  <div class=\"sys-diagram\">\n    <div class=\"sys-box scheme-a\">\n      <h4 style=\"color:#c0392b;\">\u5929\u6c1f\u5730\u6c34 \u00b7 \u7cfb\u7edf\u67b6\u6784<\/h4>\n      <div class=\"sys-item\">\u5c0a\u777f180\u5916\u673a\uff08\u6c1f\u7cfb\u7edf\uff09<\/div>\n      <div class=\"sys-item\" style=\"margin:4px 20px; font-size:12px; color:#999;\">\u6c1f\u5229\u6602\u4e00\u6b21\u6362\u70ed \u00b7 \u4e09\u7ba1\u5236<\/div>\n      <div class=\"sys-item\">6\u53f0\u5ba4\u5185\u673a\uff08\u5236\u51b7\/\u9664\u6e7f\/\u51c0\u5316\uff09<\/div>\n      <div class=\"sys-item\" style=\"margin:8px 0; font-size:12px; color:#999;\">+ 160\u5916\u7f6e\u6c34\u6a21\u5757\uff08\u6362\u70ed\u5668\uff09<\/div>\n      <div class=\"sys-item\">\u5730\u6696\u6c34\u8def\uff08\u91c7\u6696\uff09<\/div>\n    <\/div>\n  <\/div>\n\n  <h3>\u91c7\u6696\u8bbe\u5907\u660e\u7ec6<\/h3>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u89c4\u683c<\/th><th>\u9762\u4ef7(\u5143)<\/th><th>\u8bbe\u5907\u4ef7(\u5143)<\/th><th>\u5b89\u88c5\u8d39(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u6c34\u6a21\u5757<\/strong><\/td>\n        <td class=\"ta-left\">RWMG-160FWXNZQ<\/td>\n        <td>160\u578b\u5916\u7f6e\u5f0f \/ 16kW\u6362\u70ed<\/td>\n        <td class=\"ta-right\">8,375<\/td>\n        <td class=\"ta-right\"><strong>8,375<\/strong><\/td>\n        <td class=\"ta-right\">625<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u5730\u6696\u94fa\u8bbe<\/td>\n        <td class=\"ta-left\">\u2014<\/td>\n        <td>123\u33a1 \u00d7 179\u5143\/\u33a1\uff08\u4f1f\u661f\u767d\u6676+\u963b\u6c27\u7ba1+\u5206\u63a7\uff09<\/td>\n        <td class=\"ta-right\">\u2014<\/td>\n        <td class=\"ta-right\">22,017<\/td>\n        <td class=\"ta-right\">\u542b\u65bd\u5de5<\/td>\n      <\/tr>\n      <tr class=\"highlight-row\">\n        <td colspan=\"3\" class=\"ta-left\"><strong>\u91c7\u6696\u90e8\u5206\u5408\u8ba1<\/strong><\/td>\n        <td class=\"ta-right\">\u2014<\/td>\n        <td class=\"ta-right\"><strong>30,392<\/strong><\/td>\n        <td class=\"ta-right\">625<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3>\u65b9\u6848\u4e00\u8d39\u7528\u6c47\u603b<\/h3>\n  <table>\n    <tbody>\n      <tr><td class=\"ta-left\" style=\"width:220px;\">\u7a7a\u8c03\u8bbe\u5907 + \u5b89\u88c5<\/td><td class=\"ta-right\">58,935<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u6c34\u6a21\u5757\u8bbe\u5907 + \u5b89\u88c5<\/td><td class=\"ta-right\">9,000<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u5730\u6696\u94fa\u8bbe\uff08123\u33a1 \u00d7 179\u5143\/\u33a1\uff09<\/td><td class=\"ta-right\">22,017<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u5c0f\u8ba1<\/td><td class=\"ta-right\">89,952<\/td><\/tr>\n      <tr><td class=\"ta-left\">618\u6d3b\u52a8\u4f18\u60e0\uff08\u5929\u6c1f\u5730\u6c34\u4e13\u5c5e\uff09<\/td><td class=\"ta-right\" style=\"color:#c0392b;\">-2,000<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u5ef6\u4fdd\u8d39\u7528\uff08\u7b7e\u7ea6\u514d\u8d39\u900110\u5e74\u8d28\u4fdd\uff09<\/td><td class=\"ta-right\" style=\"color:#27ae60;\">\u514d\u8d39<\/td><\/tr>\n      <tr class=\"total-row\"><td class=\"ta-left\">618\u6d3b\u52a8\u540e\u5b9e\u4ed8<\/td><td class=\"ta-right\" style=\"font-size:20px; color:#c0392b;\">87,952<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- \u65b9\u6848\u4e8c\uff1a\u58c1\u6302\u7089 -->\n<div class=\"section\">\n  <h2>\u65b9\u6848\u4e8c\uff1a\u5c0a\u777f\u7a7a\u8c03 + \u83f2\u65af\u66fc\u58c1\u6302\u7089 <span class=\"tag tag-blue\">\u72ec\u7acb\u91c7\u6696<\/span><\/h2>\n  <p style=\"color:#666; margin-bottom:16px; font-size:14px;\">\n    \u7a7a\u8c03\u4e0e\u91c7\u6696<strong>\u5b8c\u5168\u5206\u79bb<\/strong>\uff1a\u5c0a\u777f\u5168\u6548II 180\u578b\u4e00\u62d6\u516d\u8d1f\u8d23\u590f\u5b63\u5236\u51b7\u53ca\u8fc7\u6e21\u5b63\u70ed\u6cf5\u5236\u70ed\uff1b\u83f2\u65af\u66fcB1JG 25kW\u51b7\u51dd\u58c1\u6302\u7089\u72ec\u7acb\u8d1f\u8d23\u51ac\u5b63\u5730\u6696\u91c7\u6696 + \u5168\u5e74\u751f\u6d3b\u70ed\u6c34\u3002<strong>\u53cc\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\uff0c\u4e92\u4e0d\u5f71\u54cd\u3002<\/strong>\n  <\/p>\n\n  <div class=\"sys-diagram\">\n    <div class=\"sys-box scheme-b\">\n      <h4 style=\"color:#2980b9;\">\u58c1\u6302\u7089 \u00b7 \u72ec\u7acb\u91c7\u6696\u67b6\u6784<\/h4>\n      <div class=\"sys-item\">\u5c0a\u777f180\u5916\u673a\uff08\u7eaf\u7a7a\u8c03\uff09<\/div>\n      <div class=\"sys-item\" style=\"margin:4px 20px; font-size:12px; color:#999;\">\u5236\u51b7\/\u9664\u6e7f\/\u70ed\u6cf5\u5236\u70ed<\/div>\n      <div class=\"sys-item\">6\u53f0\u5ba4\u5185\u673a<\/div>\n      <div class=\"sys-item\" style=\"border-top:2px dashed #2980b9; margin-top:12px; padding-top:8px; font-size:12px; color:#999;\">\u5b8c\u5168\u72ec\u7acb<\/div>\n      <div class=\"sys-item\" style=\"background:#e8f0fd;\">\u83f2\u65af\u66fcB1JG 25kW \u58c1\u6302\u7089<\/div>\n      <div class=\"sys-item\">\u5730\u6696\u6c34\u8def + \u751f\u6d3b\u70ed\u6c34<\/div>\n    <\/div>\n  <\/div>\n\n  <h3>\u91c7\u6696\u8bbe\u5907\u660e\u7ec6<\/h3>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u5b89\u88c5\u8d39(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u58c1\u6302\u7089<\/strong><\/td>\n        <td class=\"ta-left\">Vitodens 100-C B1JG 25KW<\/td>\n        <td>\u56fd\u4ea7\u51b7\u51dd\u7089 \/ \u70ed\u6548\u7387108% \/ \u91c7\u6696+\u70ed\u6c34<\/td>\n        <td class=\"ta-right\"><strong>12,237<\/strong><\/td>\n        <td class=\"ta-right\">600<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u5730\u6696\u94fa\u8bbe<\/td>\n        <td class=\"ta-left\">\u2014<\/td>\n        <td>123\u33a1 \u00d7 169\u5143\/\u33a1\uff08\u4f1f\u661f\u767d\u6676+\u963b\u6c27\u7ba1+\u5206\u63a7\uff09<\/td>\n        <td class=\"ta-right\">20,787<\/td>\n        <td class=\"ta-right\">\u542b\u65bd\u5de5<\/td>\n      <\/tr>\n      <tr class=\"highlight-row\">\n        <td colspan=\"3\" class=\"ta-left\"><strong>\u91c7\u6696\u90e8\u5206\u5408\u8ba1<\/strong><\/td>\n        <td class=\"ta-right\"><strong>33,024<\/strong><\/td>\n        <td class=\"ta-right\">600<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n  <p class=\"note-line\">\u83f2\u65af\u66fc\u58c1\u6302\u7089\u4e3a\u5355\u4ef7\u4ea7\u54c1\uff0c\u672c\u6b219\u6298\u4f18\u60e0<\/p>\n  <p class=\"note-line\">\u58c1\u6302\u7089\u5185\u7f6e\u6362\u70ed\u5668 + \u53d8\u9891\u6c34\u6cf5 + \u81a8\u80c0\u7f50\uff0c\u65e0\u9700\u989d\u5916\u914d\u7f6e\u6c34\u6a21\u5757<\/p>\n\n  <h3>\u65b9\u6848\u4e8c\u8d39\u7528\u6c47\u603b<\/h3>\n  <table>\n    <tbody>\n      <tr><td class=\"ta-left\" style=\"width:220px;\">\u7a7a\u8c03\u8bbe\u5907 + \u5b89\u88c5<\/td><td class=\"ta-right\">58,935<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u83f2\u65af\u66fcB1JG \u58c1\u6302\u7089 + \u5b89\u88c5<\/td><td class=\"ta-right\">12,837<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u5730\u6696\u94fa\u8bbe\uff08123\u33a1 \u00d7 169\u5143\/\u33a1\uff09<\/td><td class=\"ta-right\">20,787<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u5c0f\u8ba1<\/td><td class=\"ta-right\">92,559<\/td><\/tr>\n      <tr><td class=\"ta-left\">618\u5b9a\u91d1\u81a8\u80c0\uff0819.9\u5143\u62b51,000\u5143\uff09<\/td><td class=\"ta-right\" style=\"color:#c0392b;\">-1,000<\/td><\/tr>\n      <tr><td class=\"ta-left\">\u5ef6\u4fdd\u8d39\u7528\uff08\u7b7e\u7ea6\u514d\u8d39\u900110\u5e74\u8d28\u4fdd\uff09<\/td><td class=\"ta-right\" style=\"color:#27ae60;\">\u514d\u8d39<\/td><\/tr>\n      <tr class=\"total-row\"><td class=\"ta-left\">618\u6d3b\u52a8\u540e\u5b9e\u4ed8<\/td><td class=\"ta-right\" style=\"font-size:20px; color:#2980b9;\">91,559<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- \u5feb\u901f\u5bf9\u6bd4 -->\n<div class=\"section\">\n  <h2>\u4e24\u5957\u65b9\u6848\u5feb\u901f\u5bf9\u6bd4<\/h2>\n\n  <div class=\"compare-grid\">\n    <div class=\"compare-card scheme-a\">\n      <div class=\"card-tag\"><span class=\"tag tag-red\">\u65b9\u6848\u4e00<\/span> <strong>\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b<\/strong><\/div>\n      <p style=\"font-size:13px; color:#666;\">\u4e00\u5957\u4e3b\u673a\uff0c\u7a7a\u8c03+\u5730\u6696\u5168\u641e\u5b9a<\/p>\n      <div class=\"card-price\" style=\"color:#c0392b;\">87,952 <small>\u5143<\/small><\/div>\n      <table style=\"font-size:13px; margin:10px 0;\">\n        <tr><td class=\"ta-left\">\u7a7a\u8c03<\/td><td class=\"ta-right\">58,935<\/td><\/tr>\n        <tr><td class=\"ta-left\">+ 160\u6c34\u6a21\u5757<\/td><td class=\"ta-right\">9,000<\/td><\/tr>\n        <tr><td class=\"ta-left\">+ \u5730\u6696123\u33a1<\/td><td class=\"ta-right\">22,017<\/td><\/tr>\n        <tr style=\"border-top:1px solid #ddd;\"><td class=\"ta-left\">- 618\u4f18\u60e0<\/td><td class=\"ta-right\" style=\"color:#c0392b;\">-2,000<\/td><\/tr>\n        <tr style=\"font-weight:700;\"><td class=\"ta-left\">\u5b9e\u4ed8<\/td><td class=\"ta-right\" style=\"font-size:16px; color:#c0392b;\">87,952<\/td><\/tr>\n      <\/table>\n      <ul class=\"feature-list\">\n        <li style=\"color:#27ae60;\">\u4e00\u5957\u7cfb\u7edf\u7edf\u4e00\u63a7\u5236\uff0c\u64cd\u4f5c\u7b80\u5355<\/li>\n        <li style=\"color:#27ae60;\">\u7a7a\u6c14\u6e90\u70ed\u6cf5\u5236\u70ed COP 3-4\uff0c\u6bd4\u71c3\u6c14\u770140-60%<\/li>\n        <li style=\"color:#27ae60;\">\u4e3b\u673a\u5bff\u547d20\u5e74+\uff0c\u65e0\u9700\u4e2d\u9014\u66f4\u6362<\/li>\n        <li style=\"color:#27ae60;\">20\u5e74\u603b\u6301\u6709\u6210\u672c\u4ec5\u7ea613\u4e07\uff0c\u7701\u8fd13\u4e07<\/li>\n        <li style=\"color:#27ae60;\">\u53ef\u5347\u7ea7\u4e94\u6052+\uff08\u5168\u5c4b\u5168\u611f3.0\uff09<\/li>\n        <li style=\"color:#e74c3c;\">\u9700\u5916\u7f6e\u6c34\u6a21\u5757\uff0c\u5360\u5b89\u88c5\u7a7a\u95f4<\/li>\n        <li style=\"color:#e74c3c;\">\u6781\u7aef\u4f4e\u6e29\uff08-25\u2103\u4ee5\u4e0b\uff09\u5236\u70ed\u7565\u6709\u8870\u51cf<\/li>\n        <li style=\"color:#e74c3c;\">\u4e0d\u63d0\u4f9b\u751f\u6d3b\u70ed\u6c34\uff08\u9700\u53e6\u914d\u70ed\u6c34\u5668\uff09<\/li>\n      <\/ul>\n    <\/div>\n\n    <div class=\"compare-card scheme-b\">\n      <div class=\"card-tag\"><span class=\"tag tag-blue\">\u65b9\u6848\u4e8c<\/span> <strong>\u83f2\u65af\u66fc\u58c1\u6302\u7089<\/strong><\/div>\n      <p style=\"font-size:13px; color:#666;\">\u53cc\u7cfb\u7edf\u72ec\u7acb\uff0c\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34<\/p>\n      <div class=\"card-price\" style=\"color:#2980b9;\">91,559 <small>\u5143<\/small><\/div>\n      <table style=\"font-size:13px; margin:10px 0;\">\n        <tr><td class=\"ta-left\">\u7a7a\u8c03<\/td><td class=\"ta-right\">58,935<\/td><\/tr>\n        <tr><td class=\"ta-left\">+ \u83f2\u65af\u66fc\u58c1\u6302\u7089<\/td><td class=\"ta-right\">12,837<\/td><\/tr>\n        <tr><td class=\"ta-left\">+ \u5730\u6696123\u33a1<\/td><td class=\"ta-right\">20,787<\/td><\/tr>\n        <tr style=\"border-top:1px solid #ddd;\"><td class=\"ta-left\">- 618\u4f18\u60e0<\/td><td class=\"ta-right\" style=\"color:#c0392b;\">-1,000<\/td><\/tr>\n        <tr style=\"font-weight:700;\"><td class=\"ta-left\">\u5b9e\u4ed8<\/td><td class=\"ta-right\" style=\"font-size:16px; color:#2980b9;\">91,559<\/td><\/tr>\n      <\/table>\n      <ul class=\"feature-list\">\n        <li style=\"color:#27ae60;\">\u53cc\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\uff0c\u4e92\u4e0d\u5f71\u54cd<\/li>\n        <li style=\"color:#27ae60;\">\u81ea\u5e26\u751f\u6d3b\u70ed\u6c34\uff0824kW\u5373\u70ed\uff09<\/li>\n        <li style=\"color:#27ae60;\">-30\u2103\u6781\u5bd2\u5929\u6c14\u5236\u70ed\u7a33\u5b9a<\/li>\n        <li style=\"color:#27ae60;\">\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\uff08\u989d\u5b9a\u5de5\u51b5\uff09<\/li>\n        <li style=\"color:#e74c3c;\">\u521d\u88c5\u8d35\u7ea63,607\u5143\uff0c20\u5e74\u8d35\u7ea630,607\u5143<\/li>\n        <li style=\"color:#e74c3c;\">\u7b2c12\u5e74\u9700\u66f4\u6362\u9505\u7089\uff08\u7ea613,000\u5143\uff09<\/li>\n        <li style=\"color:#e74c3c;\">\u9891\u7e41\u542f\u505c\u81f4\u5b9e\u9645\u80fd\u8017\u9ad8\u4e8e\u7406\u8bba\u503c<\/li>\n        <li style=\"color:#e74c3c;\">\u4e24\u5957\u7cfb\u7edf\u9700\u5206\u5f00\u63a7\u5236<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- \u6df1\u5ea6\u5bf9\u6bd4 -->\n<div class=\"section\">\n  <h2>\u5341\u7ef4\u6df1\u5ea6\u5bf9\u6bd4\u5206\u6790 <span style=\"font-size:14px; color:#999; font-weight:400;\">\u542b20\u5e74\u5168\u751f\u547d\u5468\u671f<\/span><\/h2>\n\n  <table class=\"analysis-table\">\n    <thead>\n      <tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00 \u00b7 \u5929\u6c1f\u5730\u6c34<\/th><th>\u65b9\u6848\u4e8c \u00b7 \u83f2\u65af\u66fc\u58c1\u6302\u7089<\/th><th>\u5206\u6790<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td>\u521d\u59cb\u6295\u8d44\uff08618\u5b9e\u4ed8\uff09<\/td>\n        <td class=\"winner\">87,952 \u5143<\/td>\n        <td>91,559 \u5143<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u65b9\u6848\u4e00\u4f4e\u7ea63,607\u5143\u3002\u65b9\u6848\u4e8c\u591a\u51fa\u58c1\u6302\u7089\u8d39\u7528\uff0c\u4f46\u81ea\u5e26\u751f\u6d3b\u70ed\u6c34\u529f\u80fd<\/td>\n      <\/tr>\n      <tr>\n        <td>\u7cfb\u7edf\u96c6\u6210\u5ea6<\/td>\n        <td class=\"winner\">\u4e00\u5957\u7cfb\u7edf\uff0c\u7edf\u4e00\u63a7\u5236<\/td>\n        <td>\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u65b9\u6848\u4e00\u64cd\u4f5c\u7b80\u4fbf\uff1b\u65b9\u6848\u4e8c\u9700\u5206\u5f00\u5b66\u4e60\u4e24\u5957\u63a7\u5236\u7cfb\u7edf<\/td>\n      <\/tr>\n      <tr>\n        <td>\u51ac\u5b63\u91c7\u6696\u8d39\u7528<\/td>\n        <td class=\"winner\">\u70ed\u6cf5COP 3-4\uff0c\u7701\u7535<\/td>\n        <td>\u71c3\u6c14\u8d39\u7528\u8f83\u9ad8<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u6210\u90fd\u5730\u533a\uff0c\u65b9\u6848\u4e00\u91c7\u6696\u5b63\u7ea6\u7535\u8d391,500-2,500\u5143\uff1b\u65b9\u6848\u4e8c\u7ea6\u71c3\u6c14\u8d392,500-4,000\u5143<\/td>\n      <\/tr>\n      <tr>\n        <td>\u91c7\u6696\u8212\u9002\u5ea6<\/td>\n        <td>\u5730\u6696\u6c34\u7cfb\u7edf\uff0c\u8212\u9002<\/td>\n        <td>\u5730\u6696\u6c34\u7cfb\u7edf\uff0c\u8212\u9002<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u540c\u4e3a\u6c34\u5730\u6696\uff0c\u91c7\u6696\u8212\u9002\u5ea6\u65e0\u5dee\u5f02<\/td>\n      <\/tr>\n      <tr>\n        <td>\u751f\u6d3b\u70ed\u6c34<\/td>\n        <td>\u9700\u53e6\u914d\u70ed\u6c34\u5668<\/td>\n        <td class=\"winner\">\u81ea\u5e2624kW\u5373\u70ed\u70ed\u6c34<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u65b9\u6848\u4e8c\u58c1\u6302\u7089\u81ea\u5e26\u751f\u6d3b\u70ed\u6c34\u529f\u80fd\uff0c\u8282\u7701\u4e00\u53f0\u71c3\u6c14\u70ed\u6c34\u5668\uff08\u7ea62,000-3,000\u5143\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td>\u6781\u5bd2\u5929\u6c14\u80fd\u529b<\/td>\n        <td>-25\u2103~60\u2103<\/td>\n        <td class=\"winner\">-30\u2103\u7a33\u5b9a\u5236\u70ed<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u6210\u90fd\u5730\u533a\u6781\u5c11\u4f4e\u4e8e-5\u2103\uff0c\u4e24\u5957\u65b9\u6848\u5747\u7ef0\u7ef0\u6709\u4f59<\/td>\n      <\/tr>\n      <tr>\n        <td>\u4e94\u6052+\u5347\u7ea7\u8def\u5f84<\/td>\n        <td class=\"winner\">\u53ef\u5347\u7ea7\u5168\u5c4b\u5168\u611f3.0<\/td>\n        <td>\u65e0\u6cd5\u7edf\u4e00\u5347\u7ea7<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u65b9\u6848\u4e00\u53ef\u63a5\u5165\u5929\u51c0\u65b0\u98ce+AI\u96c6\u63a7\u5c4f\uff0c\u5b9e\u73b0\u4e94\u7ef4\u7a7a\u6c14\u7ba1\u7406<\/td>\n      <\/tr>\n      <tr>\n        <td>\u7ef4\u62a4\u4fbf\u5229\u6027<\/td>\n        <td>\u4e00\u5957\u7cfb\u7edf\u7edf\u4e00\u552e\u540e<\/td>\n        <td class=\"winner\">\u53cc\u7cfb\u7edf\u72ec\u7acb\u7ef4\u62a4<\/td>\n        <td style=\"font-size:13px; color:#666;\">\u65b9\u6848\u4e8c\u4efb\u4e00\u7cfb\u7edf\u6545\u969c\u4e0d\u5f71\u54cd\u53e6\u4e00\u7cfb\u7edf\uff1b\u65b9\u6848\u4e00\u6c34\u6a21\u5757\u6545\u969c\u5f71\u54cd\u5730\u6696\u4f46\u4e0d\u5f71\u54cd\u7a7a\u8c03<\/td>\n      <\/tr>\n      <tr>\n        <td>\u8bbe\u5907\u5bff\u547d<\/td>\n        <td class=\"winner\">20\u5e74+\uff08\u4e3b\u673a\u4e0d\u7528\u6362\uff09<\/td>\n        <td>10-15\u5e74\uff08\u7b2c12\u5e74\u9700\u66f4\u6362\uff09<\/td>\n        <td style=\"font-size:13px; color:#e67e22;\">\u65b9\u6848\u4e00\u65e0\u9700\u4e2d\u9014\u66f4\u6362\u6838\u5fc3\u8bbe\u5907\u3002\u65b9\u6848\u4e8c\u9884\u8ba1\u7b2c12\u5e74\u66f4\u6362\u9505\u7089\uff08\u7ea613,000\u5143\uff09\uff0c\u662f\"\u9690\u6027\u6210\u672c\"<\/td>\n      <\/tr>\n      <tr>\n        <td>20\u5e74\u6301\u6709\u603b\u6210\u672c<\/td>\n        <td class=\"winner\">\u7ea6131,952 \u5143<\/td>\n        <td>\u7ea6162,559 \u5143<\/td>\n        <td style=\"font-size:13px; color:#27ae60; font-weight:600;\">\u65b9\u6848\u4e0020\u5e74\u7d2f\u8ba1\u7701\u7ea630,607\u5143\u3002\u542b\u521d\u88c5+\u8fd0\u884c+\u8bbe\u5907\u66f4\u6362<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- \u8fd0\u884c\u6210\u672c\u5bf9\u6bd4 -->\n<div class=\"section\">\n  <h2>\u91c7\u6696\u8fd0\u884c\u6210\u672c\u5bf9\u6bd4 <span style=\"font-size:14px; color:#999; font-weight:400;\">\u6210\u90fd\u5730\u533a\u4f30\u7b97<\/span><\/h2>\n\n  <table>\n    <thead>\n      <tr><th>\u6210\u672c\u9879<\/th><th>\u65b9\u6848\u4e00 \u00b7 \u5929\u6c1f\u5730\u6c34<\/th><th>\u65b9\u6848\u4e8c \u00b7 \u83f2\u65af\u66fc\u58c1\u6302\u7089<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u70ed\u6e90\u80fd\u6548<\/strong><\/td>\n        <td>COP 3.0~4.0\uff08\u7a7a\u6c14\u6e90\u70ed\u6cf5\uff09<\/td>\n        <td>\u70ed\u6548\u7387108%\uff08\u51b7\u51dd\u7089\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u80fd\u6e90\u5355\u4ef7<\/strong><\/td>\n        <td>\u7535 0.54\u5143\/kWh\uff08\u6210\u90fd\u9636\u68af\u7535\u4ef7\uff09<\/td>\n        <td>\u5929\u7136\u6c14 2.13\u5143\/m\u00b3\uff08\u6210\u90fd\u4e8c\u9636\u68af\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u5355\u65e5\u91c7\u6696\u80fd\u8017<\/strong><\/td>\n        <td>\u7ea6 20~30 kWh\/\u5929<\/td>\n        <td>\u7ea6 8~12 m\u00b3\/\u5929<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u5355\u65e5\u91c7\u6696\u8d39\u7528<\/strong><\/td>\n        <td style=\"color:#27ae60;\">\u7ea6 11~16 \u5143<\/td>\n        <td>\u7ea6 17~26 \u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u91c7\u6696\u5b63\u8d39\u7528\uff0890\u5929\uff09<\/strong><\/td>\n        <td style=\"color:#27ae60;\">\u7ea6 1,000~1,500 \u5143<\/td>\n        <td>\u7ea6 1,500~2,300 \u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>5\u5e74\u91c7\u6696\u603b\u8d39\u7528<\/strong><\/td>\n        <td style=\"color:#27ae60;\">\u7ea6 5,000~7,500 \u5143<\/td>\n        <td>\u7ea6 7,500~11,500 \u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>10\u5e74\u91c7\u6696\u603b\u8d39\u7528<\/strong><\/td>\n        <td style=\"color:#27ae60;\">\u7ea6 10,000~15,000 \u5143<\/td>\n        <td>\u7ea6 15,000~23,000 \u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>20\u5e74\u91c7\u6696\u603b\u8d39\u7528<\/strong><\/td>\n        <td style=\"color:#27ae60;\">\u7ea6 20,000~30,000 \u5143<\/td>\n        <td>\u7ea6 30,000~46,000 \u5143<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"insight-box\" style=\"margin-top:16px;\">\n    <h4>\u4ece5\u5e74\u523020\u5e74\uff1a\u65f6\u95f4\u8d8a\u957f\uff0c\u5dee\u8ddd\u8d8a\u5927<\/h4>\n    <p><strong>5\u5e74\u89c6\u89d2\uff1a<\/strong>\u65b9\u6848\u4e00\u7701\u7ea66,000-8,000\u5143\uff08\u521d\u88c5\u5dee+\u8fd0\u884c\u8d39\u5dee\uff09<\/p>\n    <p><strong>10\u5e74\u89c6\u89d2\uff1a<\/strong>\u65b9\u6848\u4e00\u7701\u7ea613,000-19,000\u5143\u3002\u65b9\u6848\u4e8c\u65e0\u9700\u6362\u9505\u7089\uff08\u5c1a\u5728\u5bff\u547d\u5185\uff09\uff0c\u5dee\u8ddd\u4e3b\u8981\u6765\u81ea\u8fd0\u884c\u8d39<\/p>\n    <p><strong>20\u5e74\u89c6\u89d2\uff1a<\/strong>\u65b9\u6848\u4e00\u7701\u7ea6<strong style=\"color:#c0392b;\">30,607\u5143<\/strong>\u3002\u65b9\u6848\u4e8c\u7b2c12\u5e74\u9700\u66f4\u6362\u9505\u7089\uff08\u7ea613,000\u5143\uff09\uff0c\u6210\u4e3a\u6700\u5927\u9690\u6027\u652f\u51fa<\/p>\n    <p style=\"margin-top:8px; color:#666; font-size:13px;\">\u751f\u6d3b\u70ed\u6c34\u65b9\u9762\uff1a\u65b9\u6848\u4e8c\u81ea\u5e26\u70ed\u6c34\u770b\u4f3c\u4fbf\u5229\uff0c\u4f46\u4e24\u7528\u7089\u975e\u91c7\u6696\u5b63\"\u70ed\u6c34\u8fc7\u70eb\"\u662f\u666e\u904d\u75db\u70b9\uff08\u6700\u5c0f\u529f\u7387~8kW\u8fdc\u8d85\u6d17\u6fa1\u6240\u97003-5kW\uff09\u3002\u5982\u9700\u8212\u9002\u6052\u6e29\u70ed\u6c34\uff0c\u72ec\u7acb\u71c3\u6c14\u70ed\u6c34\u5668\uff08\u7ea62,000\u5143\uff09\u53cd\u800c\u4f53\u9a8c\u66f4\u597d\u3002<\/p>\n  <\/div>\n<\/div>\n\n<!-- \u58c1\u6302\u7089\u6280\u672f\u75db\u70b9 -->\n<div class=\"section\">\n  <h2>\u58c1\u6302\u7089\u6280\u672f\u539f\u7406\u6df1\u5ea6\u89e3\u6790 <span style=\"font-size:14px; color:#999; font-weight:400;\">\u7406\u89e3\"\u9690\u5f62\u6210\u672c\"\u7684\u5173\u952e<\/span><\/h2>\n  \n  <div class=\"insight-box\">\n    <h4>\u6838\u5fc3\u95ee\u9898\uff1a\u6c34\u6e29\u63a7\u5236\uff0c\u800c\u975e\u5ba4\u6e29\u63a7\u5236<\/h4>\n    <p>\u58c1\u6302\u7089\u7684\u57fa\u672c\u5de5\u4f5c\u903b\u8f91\u662f\"\u8bbe\u5b9a\u6c34\u6e29(\u598260\u2103) \u2192 \u70b9\u706b\u71c3\u70e7 \u2192 \u52a0\u70ed\u5230\u76ee\u6807\u6c34\u6e29 \u2192 <strong>\u505c\u673a + \u540e\u5439\u626b<\/strong>(\u5438\u5165\u51b7\u7a7a\u6c14\u6563\u70ed) \u2192 \u6c34\u6e29\u9aa4\u964d \u2192 \u518d\u6b21\u70b9\u706b\"\uff0c\u5f62\u6210<strong>\u9891\u7e41\u542f\u505c\u7684\u6076\u6027\u5faa\u73af<\/strong>\u3002\"\u6ca1\u4eba\u544a\u8bc9\u5b83\u5ba4\u6e29\u5df2\u7ecf\u591f\u4e86\"\uff0c\u5bfc\u81f4\u5927\u91cf\u65e0\u6548\u4ea7\u70ed\u3002<\/p>\n  <\/div>\n\n  <h3>\u58c1\u6302\u7089\u5b9e\u9645\u80fd\u8017\u8fdc\u9ad8\u4e8e\u7406\u8bba\u503c\u7684\u539f\u56e0<\/h3>\n  <table>\n    <thead><tr><th>\u75db\u70b9\u73b0\u8c61<\/th><th>\u7269\u7406\u539f\u7406<\/th><th>\u540e\u679c<\/th><\/tr><\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u9891\u7e41\u542f\u505c<\/strong><\/td>\n        <td class=\"ta-left\">\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff088-10kW\uff09\u8fdc\u8d85\u672b\u7aef\u9700\u6c42\uff083-5kW\uff09\u2192 \u6c34\u6e29\u5feb\u901f\u8fbe\u6807 \u2192 \u505c\u673a \u2192 \u540e\u5439\u626b\u5438\u5165\u51b7\u7a7a\u6c14 \u2192 \u518d\u6b21\u70b9\u706b<\/td>\n        <td style=\"color:#c0392b; font-weight:600;\">\u71c3\u6c14\u6d6a\u8d39 20-30%<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u65e0\u6548\u4ea7\u70ed<\/strong><\/td>\n        <td class=\"ta-left\">\u5ba4\u6e29\u5df2\u8fbe\u6807\uff0c\u4f46\u9505\u7089\u6309\u6c34\u6e29\u6307\u4ee4\u7ee7\u7eed\u71c3\u70e7 \u2014 \"\u4eba\u8d70\u4e86\uff0c\u5c4b\u5b50\u70ed\u4e86\uff0c\u9505\u7089\u8fd8\u5728\u70e7\"<\/td>\n        <td class=\"ta-left\" style=\"color:#e67e22;\">\u80fd\u6e90\u767d\u767d\u6d6a\u8d39\uff0c\u623f\u95f4\u8fc7\u70ed<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u6e29\u5ea6\u6ce2\u52a8\u5927<\/strong><\/td>\n        <td class=\"ta-left\">\u9891\u7e41\u542f\u505c \u2192 \u51fa\u6c34\/\u56de\u6c34\u6e29\u5ea6\u5267\u70c8\u6ce2\u52a8<\/td>\n        <td class=\"ta-left\">\u4f53\u611f\u6e29\u5dee\u660e\u663e\uff0c\u8212\u9002\u5ea6\u6253\u6298<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u7cfb\u7edf\u5bff\u547d\u7f29\u77ed<\/strong><\/td>\n        <td class=\"ta-left\">\u9891\u7e41\u70b9\u706b\/\u7184\u706b \u2192 \u70ed\u4ea4\u6362\u5143\u4ef6\u53cd\u590d\u70ed\u80c0\u51b7\u7f29<\/td>\n        <td style=\"color:#c0392b; font-weight:600;\">\u710a\u70b9\u75b2\u52b3 \u2192 \u6f0f\u6c34\u98ce\u9669\u589e\u52a0<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"notice\" style=\"margin-top:16px;\">\n    <strong>\u5173\u952e\u6d1e\u5bdf\uff1a<\/strong>\u9505\u7089\u7684\u95ee\u9898\u4e0d\u662f\u5b83\"\u4e0d\u597d\"\uff0c\u800c\u662f\"\u6ca1\u4eba\u544a\u8bc9\u5b83\u5ba4\u6e29\u5df2\u7ecf\u591f\u4e86\"\u3002\u8054\u52a8\u63a7\u5236\u7cfb\u7edf\uff08\u5982\u66fc\u745e\u5fb7H-BOX\uff09\u53ef\u7f13\u89e3\u6b64\u77db\u76fe\uff0c\u8282\u80fd20-30%\u3002\u4f46\u9505\u7089\u53d7\u71c3\u70e7\u539f\u7406\u6240\u9650\uff0c\u5373\u4fbf\u4f18\u5316\u540e\uff0c\u5176\u957f\u671f\u80fd\u6548\u4ecd\u65e0\u6cd5\u4e0e\u7a7a\u6c14\u80fd\u70ed\u6cf5\uff08COP 3-4\uff09\u6297\u8861\u3002\n  <\/div>\n\n  <div class=\"divider\"><\/div>\n\n  <h3>\u4e24\u7528\u58c1\u6302\u7089\u7684\u6839\u672c\u8bbe\u8ba1\u77db\u76fe<\/h3>\n  <table>\n    <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u91c7\u6696\u9700\u6c42<\/th><th>\u751f\u6d3b\u70ed\u6c34\u9700\u6c42<\/th><th style=\"color:#c0392b;\">\u77db\u76fe\u7ed3\u679c<\/th><\/tr><\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u6240\u9700\u529f\u7387<\/strong><\/td>\n        <td><strong>\u5c0f\u800c\u7a33\uff1a<\/strong>100\u33a1\u65e5\u5e38\u6052\u6e29\u4ec5\u97005-7kW<\/td>\n        <td><strong>\u5927\u800c\u6025\uff1a<\/strong>\u4e00\u4e2a\u6dcb\u6d74\u970015-20kW\uff1b\u540c\u65f6\u6d17\u6d74+\u6d17\u7897\u970030kW+<\/td>\n        <td style=\"color:#c0392b; font-weight:600;\">\u88ab\u8feb\u9009\u5927\u529f\u7387\uff0824\/28\/35kW\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u5de5\u4f5c\u72b6\u6001<\/strong><\/td>\n        <td>\u957f\u671f\u8fd0\u884c\uff0c\u9700\u4f4e\u529f\u7387\u7a33\u5b9a\u8f93\u51fa<\/td>\n        <td>\u77ed\u671f\u51b2\u51fb\uff0c\u9700\u77ac\u65f6\u5927\u529f\u7387<\/td>\n        <td style=\"color:#c0392b;\">\u5927\u529f\u7387\u7089\u5b50\u957f\u671f\"\u5c0f\u8d1f\u8377\"\u8fd0\u884c<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u91c7\u6696\u5b63<\/strong><\/td>\n        <td colspan=\"2\">\u529f\u7387\u4e25\u91cd\u8fc7\u5269 \u2192 \u9891\u7e41\u542f\u505c \u2192 \u80fd\u8017\u98d9\u5347<\/td>\n        <td style=\"color:#c0392b; font-weight:600;\">\u71c3\u6c14\u8d39\u9ad8\u4f01<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u975e\u91c7\u6696\u5b63<\/strong><\/td>\n        <td colspan=\"2\">\u6700\u5c0f\u529f\u7387\uff08\u7ea610kW\uff09\u8fdc\u8d85\u6d17\u6fa1\u6240\u9700\uff083-5kW\uff09<\/td>\n        <td style=\"color:#c0392b; font-weight:600;\">\"\u590f\u5929\u70ed\u6c34\u70eb\u6b7b\u4eba\"<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"notice\" style=\"margin-top:12px;\">\n    <strong>\u884c\u4e1a\u7ea2\u7ebf\uff08\u9f99\u8109\u77e5\u8bc6\u5e93\u5f3a\u8c03\uff09\uff1a<\/strong>\u5f53\u91c7\u6696\u9762\u79ef \u2264 150\u33a1\u65f6\uff0c<strong>\u4e25\u7981\u4e3a\u6ee1\u8db3\u70ed\u6c34\u9700\u6c42\u800c\u9009\u7528 \u2265 28kW \u7684\u4e24\u7528\u58c1\u6302\u7089<\/strong>\u3002\u9f99\u8001\u5e08\u9879\u76ee\u91c7\u6696\u9762\u79ef123\u33a1\u3001\u9009\u62e925kW\u51b7\u51dd\u7089\uff0c\u5df2\u5c5e\u5408\u7406\u4e0a\u7ebf\uff0c\u518d\u5927\u5373\u89e6\u53d1\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u8b66\u544a\u3002\n  <\/div>\n<\/div>\n\n<!-- 20\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c -->\n<div class=\"section\">\n  <h2>20\u5e74\u5168\u751f\u547d\u5468\u671f\u603b\u6210\u672c <span style=\"font-size:14px; color:#999; font-weight:400;\">\u6838\u5fc3\u51b3\u7b56\u4f9d\u636e<\/span><\/h2>\n  \n  <div class=\"insight-box\">\n    <h4>\"\u4fbf\u5b9c\"\u7684\u7089\u5b50\u53ef\u80fd\u66f4\u8d35 \u2014 20\u5e74\u603b\u8d26\u601d\u7ef4<\/h4>\n    <p>\u53ea\u770b\u4e00\u6b21\u521d\u88c5\u4ef7\u683c\u4f1a\u4e25\u91cd\u4f4e\u4f30\u58c1\u6302\u7089\u7684\u771f\u5b9e\u6301\u6709\u6210\u672c\u3002\u666e\u901a\u7089\u521d\u88c5\u4fbf\u5b9c2-3\u5343\u5143\uff0c\u4f46<strong>20\u5e74\u591a\u82b122,700\u5143<\/strong>\u3002<span style=\"color:#c0392b; font-weight:600;\">\"20\u5e74\u603b\u8d26\"\u624d\u662f\u7406\u6027\u51b3\u7b56\u7684\u552f\u4e00\u6807\u51c6\u3002<\/span><\/p>\n  <\/div>\n\n  <h3>\u4e09\u5927\u70ed\u6e9020\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\uff08100\u33a1\u57fa\u51c6 \/ 120\u5929\u91c7\u6696\u5b63\uff09<\/h3>\n  <table>\n    <thead>\n      <tr><th>\u70ed\u6e90\u7c7b\u578b<\/th><th>\u521d\u88c5\u6210\u672c<\/th><th>\u5b63\u8fd0\u884c\u8d39<\/th><th>20\u5e74\u8fd0\u884c\u8d39<\/th><th>\u5bff\u547d\/\u66f4\u6362<\/th><th>20\u5e74\u603b\u6295\u5165<\/th><th>\u6bd4\u7a7a\u6c14\u80fd\u591a\u82b1<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\">\u666e\u901a\u58c1\u6302\u7089\uff0824kW\uff09<\/td>\n        <td class=\"ta-right\">\u7ea69,700<\/td>\n        <td class=\"ta-right\">3,780<\/td>\n        <td class=\"ta-right\">75,600<\/td>\n        <td style=\"color:#c0392b;\">8-10\u5e74\uff0c\u63621\u6b21(+10,000)<\/td>\n        <td class=\"ta-right\" style=\"font-weight:700; color:#c0392b;\">69,700<\/td>\n        <td style=\"color:#c0392b; font-weight:700;\">+22,700<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\"><strong>\u51b7\u51dd\u58c1\u6302\u7089\uff0825kW\uff09<\/strong><\/td>\n        <td class=\"ta-right\">\u7ea612,000<\/td>\n        <td class=\"ta-right\">3,156<\/td>\n        <td class=\"ta-right\">63,120<\/td>\n        <td style=\"color:#e67e22;\">10-15\u5e74\uff0c\u63621\u6b21(+12,000)<\/td>\n        <td class=\"ta-right\" style=\"font-weight:700; color:#e67e22;\">59,500<\/td>\n        <td style=\"color:#e67e22; font-weight:700;\">+12,500<\/td>\n      <\/tr>\n      <tr style=\"background:#f0fff0;\">\n        <td class=\"ta-left\" style=\"font-weight:700;\">\u7a7a\u6c14\u80fd\u70ed\u6cf5<\/td>\n        <td class=\"ta-right\" style=\"font-weight:700;\">\u7ea612,000<\/td>\n        <td class=\"ta-right\" style=\"font-weight:700;\">2,400<\/td>\n        <td class=\"ta-right\" style=\"font-weight:700;\">48,000<\/td>\n        <td style=\"color:#27ae60; font-weight:700;\">20\u5e74+ \u65e0\u9700\u66f4\u6362\u4e3b\u673a<\/td>\n        <td class=\"ta-right\" style=\"font-weight:700; font-size:16px; color:#27ae60;\">47,000<\/td>\n        <td style=\"color:#27ae60;\">\u2014 \u6700\u4f18 \u2014<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n  <p class=\"note-line\">\u6570\u636e\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a\u5730\u6696\u7cfb\u7edf\u77e5\u8bc6\u5e93\uff08longmai-nt.com\/?page_id=1976\uff09\uff0c100\u33a1\u57fa\u51c6\uff0c120\u5929\u91c7\u6696\u5b63<\/p>\n\n  <div class=\"divider\"><\/div>\n\n  <h3>\u9f99\u8001\u5e08\u9879\u76ee \u00b7 20\u5e74\u6301\u6709\u603b\u6210\u672c\u6d4b\u7b97\uff08123\u33a1 \/ \u6210\u90fd90\u5929\u91c7\u6696\u5b63\uff09<\/h3>\n  <table>\n    <thead>\n      <tr><th>\u6210\u672c\u9879<\/th><th>\u65b9\u6848\u4e00 \u00b7 \u5929\u6c1f\u5730\u6c34<\/th><th>\u65b9\u6848\u4e8c \u00b7 \u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\"><strong>\u521d\u88c5\u6295\u5165\uff08618\u5b9e\u4ed8\uff09<\/strong><\/td>\n        <td class=\"ta-right\" style=\"font-weight:600; color:#27ae60;\">87,952<\/td>\n        <td class=\"ta-right\" style=\"font-weight:600;\">91,559<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u91c7\u6696\u8bbe\u5907\u5bff\u547d<\/td>\n        <td style=\"color:#27ae60; font-weight:600;\">20\u5e74+\uff08\u5c0a\u777f\u4e3b\u673a\u65e0\u9700\u66f4\u6362\uff09<\/td>\n        <td style=\"color:#e67e22;\">10-15\u5e74\uff08\u51b7\u51dd\u7089\u9884\u8ba1\u7b2c12\u5e74\u66f4\u6362\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">20\u5e74\u5185\u8bbe\u5907\u66f4\u6362<\/td>\n        <td style=\"color:#27ae60;\">\u65e0\u9700\u66f4\u6362\uff08\u4e3b\u673a\u5bff\u547d\u8986\u76d6\u5168\u7a0b\uff09<\/td>\n        <td style=\"color:#e67e22; font-weight:600;\">\u7b2c12\u5e74\u66f4\u6362\u9505\u7089\uff08\u7ea613,000\u5143\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u5e74\u5747\u91c7\u6696\u8fd0\u884c\u8d39<\/td>\n        <td style=\"color:#27ae60;\">\u7ea62,200\u5143\/\u5e74<\/td>\n        <td>\u7ea62,900\u5143\/\u5e74<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">20\u5e74\u91c7\u6696\u8d39\u5408\u8ba1<\/td>\n        <td style=\"color:#27ae60;\">\u7ea644,000<\/td>\n        <td>\u7ea658,000<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">20\u5e74\u4e2d\u9014\u66f4\u6362\u652f\u51fa<\/td>\n        <td style=\"color:#27ae60;\">0<\/td>\n        <td style=\"color:#e67e22; font-weight:600;\">\u7ea613,000<\/td>\n      <\/tr>\n      <tr class=\"total-row\">\n        <td class=\"ta-left\"><strong>20\u5e74\u6301\u6709\u603b\u6210\u672c<\/strong><\/td>\n        <td class=\"ta-right\" style=\"font-size:18px; color:#27ae60;\"><strong>\u7ea6131,952<\/strong><\/td>\n        <td class=\"ta-right\" style=\"font-size:18px; color:#c0392b;\"><strong>\u7ea6162,559<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td colspan=\"3\" style=\"text-align:center; color:#27ae60; font-weight:700; font-size:15px; padding:14px; background:#f0fff0;\">\n          \u65b9\u6848\u4e00 \u00b7 20\u5e74\u7d2f\u8ba1\u7701\u4e0b\u7ea6 <span style=\"font-size:20px; color:#c0392b;\">30,607 \u5143<\/span> \u2014 \u591f\u4ed8\u5b69\u5b50\u51e0\u5e74\u7684\u5b66\u8d39\u4e86\n        <\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"insight-box\" style=\"margin-top:16px;\">\n    <h4>\u4e09\u4e2a\u5173\u952e\u53d1\u73b0<\/h4>\n    <p><strong>\u2460 \u521d\u88c5\u5dee3,607\u5143\uff0c20\u5e74\u5dee30,607\u5143 \u2014 \u5dee8\u500d\u4ee5\u4e0a\u3002<\/strong>\u65b9\u6848\u4e00\u4e0d\u4ec5\u521d\u88c5\u66f4\u4fbf\u5b9c\uff0c\u957f\u671f\u6301\u6709\u66f4\u662f\u5927\u5e45\u9886\u5148\u3002\u6bcf\u591a\u7528\u4e00\u5e74\uff0c\u7701\u7684\u5c31\u8d8a\u591a\u3002<\/p>\n    <p><strong>\u2461 \u83f2\u65af\u66fc\u51b7\u51dd\u708920\u5e74\u5185\u5fc5\u7136\u6362\u4e00\u6b21\u3002<\/strong>\u51b7\u51dd\u7089\u8bbe\u8ba1\u5bff\u547d10-15\u5e74\uff08\u58c1\u6302\u7089\u5b9e\u9645\u5e73\u5747\u7ea612\u5e74\uff09\uff0c\u4e2d\u9014\u66f4\u6362\u9505\u7089\u7ea6\u970013,000\u5143\u3002\u7a7a\u6c14\u80fd\u4e3b\u673a\u8bbe\u8ba1\u5bff\u547d20\u5e74+\uff0c\u5168\u7a0b\u65e0\u66f4\u6362\u6210\u672c\u3002<\/p>\n    <p><strong>\u2462 \u4e24\u7528\u7089\u751f\u6d3b\u70ed\u6c34\u7684\u9690\u5f62\u6210\u672c\u3002<\/strong>\u65b9\u6848\u4e8c\u58c1\u6302\u7089\u81ea\u5e26\u70ed\u6c34\u770b\u4f3c\u65b9\u4fbf\uff0c\u4f46\u4e24\u7528\u7089\u5148\u5929\u77db\u76fe\uff08\u91c7\u6696\u9700\u5c0f\u529f\u7387\u3001\u70ed\u6c34\u9700\u5927\u529f\u7387\uff09\u5bfc\u81f4\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb\u3001\u51ac\u5b63\u9891\u7e41\u542f\u505c\uff0c\u5b9e\u9645\u70ed\u6c34\u4f53\u9a8c\u4e0d\u5982\u72ec\u7acb\u7cfb\u7edf\u3002<\/p>\n  <\/div>\n<\/div>\n\n<!-- COP\u80fd\u6548\u6df1\u5ea6\u5206\u6790 -->\n<div class=\"section\">\n  <h2>COP \u80fd\u6548\u6df1\u5ea6\u5206\u6790 <span style=\"font-size:14px; color:#999; font-weight:400;\">\u8282\u80fd\u4e0d\u662f\u53e3\u53f7\uff0c\u662f\u7269\u7406\u5b9a\u5f8b<\/span><\/h2>\n\n  <div class=\"insight-box\">\n    <h4>COP\uff08\u80fd\u6548\u6bd4\uff09\u7684\u672c\u8d28\uff1a\u82b11\u5ea6\u7535\uff0c\u4ea7\u51fa\u51e0\u5ea6\u70ed\uff1f<\/h4>\n    <p>\u7a7a\u6c14\u80fd\u70ed\u6cf5\u6d88\u80171\u4efd\u7535\u80fd\uff0c\u9a71\u52a8\u538b\u7f29\u673a\u4ece\u5ba4\u5916\u7a7a\u6c14\u4e2d\"\u642c\u8fd0\"2-3\u4efd\u514d\u8d39\u4f4e\u54c1\u4f4d\u70ed\u91cf\uff0c\u4ea7\u751f<strong>3-4\u4efd\u70ed\u91cf\uff08COP=3-4\uff09<\/strong>\u3002\u8fd9\u662f<strong>\u70ed\u91cf\u642c\u8fd0<\/strong>\uff0c\u4e0d\u662f\u80fd\u91cf\u8f6c\u5316\u3002\u58c1\u6302\u7089\u70e7\u5929\u7136\u6c14\u4ea7\u70ed\uff0c1m\u00b3\u6c14\u224810kWh\u70ed\u91cf\uff0c\u4f46\u56e0\u9891\u7e41\u542f\u505c\u548c\u540e\u5439\u626b\uff0c\u5b9e\u9645\u5229\u7528\u6548\u7387\u5927\u6253\u6298\u6263\u3002<\/p>\n  <\/div>\n\n  <div class=\"compare-grid\">\n    <div class=\"compare-card scheme-a\">\n      <h4 style=\"color:#27ae60; margin-bottom:12px;\">\u7a7a\u6c14\u80fd\u70ed\u6cf5 \u00b7 COP \u968f\u5de5\u51b5\u53d8\u5316<\/h4>\n      <table style=\"font-size:13px; width:100%;\">\n        <tr><th style=\"width:80px;\">\u51fa\u6c34\u6e29\u5ea6<\/th><th style=\"width:70px;\">COP<\/th><th>\u9002\u7528\u672b\u7aef<\/th><\/tr>\n        <tr><td>35\u2103<\/td><td style=\"color:#27ae60; font-weight:700;\">4.0-4.5<\/td><td>\u5730\u6696\uff08\u6700\u9ad8\u6548\u533a\u95f4\uff09<\/td><\/tr>\n        <tr><td>45\u2103<\/td><td style=\"color:#27ae60; font-weight:700;\">3.5-4.0<\/td><td>\u5730\u6696<\/td><\/tr>\n        <tr><td>55\u2103<\/td><td>2.5-3.0<\/td><td>\u4f4e\u6e29\u6696\u6c14\u7247<\/td><\/tr>\n      <\/table>\n      <p style=\"font-size:12px; color:#666; margin-top:8px;\">\u5ba4\u59167\u2103\uff08\u6210\u90fd\u51ac\u5b63\u5e38\u6001\uff09\uff1aCOP 3.8-4.2<\/p>\n      <p style=\"font-size:12px; color:#666;\">\u5ba4\u5916-5\u2103\uff1a\u8865\u6c14\u589e\u7113 COP 2.2-2.8<\/p>\n      <p style=\"font-size:12px; color:#27ae60; margin-top:8px; font-weight:600;\">\u914d\u5730\u6696\uff0835-45\u2103\u51fa\u6c34\uff09= COP\u59cb\u7ec8 > 3.5<\/p>\n    <\/div>\n    <div class=\"compare-card scheme-b\">\n      <h4 style=\"color:#2980b9; margin-bottom:12px;\">\u51b7\u51dd\u58c1\u6302\u7089 \u00b7 \u70ed\u6548\u7387\u7684\"\u5929\u82b1\u677f\"<\/h4>\n      <table style=\"font-size:13px; width:100%;\">\n        <tr><th style=\"width:90px;\">\u5de5\u51b5<\/th><th style=\"width:70px;\">\u70ed\u6548\u7387<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u989d\u5b9a\u5de5\u51b5<\/td><td style=\"font-weight:600;\">108%<\/td><td>\u51b7\u51dd\u4f59\u70ed\u56de\u6536\uff08\u7406\u8bba\u6700\u4f18\uff09<\/td><\/tr>\n        <tr><td>\u9891\u7e41\u542f\u505c<\/td><td style=\"color:#e74c3c;\">~80-90%<\/td><td>\u540e\u5439\u626b + \u51b7\u7a7a\u6c14\u5438\u5165<\/td><\/tr>\n        <tr><td>\u65e0\u6548\u4ea7\u70ed<\/td><td style=\"color:#e74c3c;\">~70-85%<\/td><td>\u5ba4\u6e29\u5df2\u8fbe\u6807\uff0c\u4ecd\u7ee7\u7eed\u71c3\u70e7<\/td><\/tr>\n      <\/table>\n      <p style=\"font-size:12px; color:#666; margin-top:8px;\">\u6700\u5c0f\u8f93\u51fa\u22488kW\uff0c\u65e5\u5e38\u9700\u6c42\u4ec53-5kW<\/p>\n      <p style=\"font-size:12px; color:#666;\">\u6c34\u6e29\u63a7\u5236\u800c\u975e\u5ba4\u6e29\u63a7\u5236 \u2192 \u65e0\u6548\u4ea7\u70ed<\/p>\n      <p style=\"font-size:12px; color:#c0392b; margin-top:8px; font-weight:600;\">108%\u662f\u5b9e\u9a8c\u5ba4\u6570\u636e\uff0c\u5b9e\u9645\u7ea6 85-95%<\/p>\n    <\/div>\n  <\/div>\n\n  <div class=\"highlight-box\" style=\"margin-top:16px;\">\n    <h4>\u6210\u90fd\u51ac\u5b63\u5b9e\u6d4b\u5bf9\u6bd4<\/h4>\n    <p><strong>\u7a7a\u6c14\u80fd = \"\u642c\u8fd0\u5de5\"\uff1a<\/strong>\u5ba4\u59167\u2103\u65f6COP\u8fbe3.8-4.2\uff0c\u82b11\u5ea6\u7535\u642c\u67654\u5ea6\u70ed\u3002\u5c0a\u777f\u5168\u6548II\u8865\u6c14\u589e\u7113\u673a\u578b\u914d\u5408\u5730\u6696\u4f4e\u6e29\u672b\u7aef\uff0835-45\u2103\u51fa\u6c34\uff09\uff0c\u6574\u4e2a\u91c7\u6696\u5b63COP\u59cb\u7ec8\u57283.5\u4ee5\u4e0a\u3002<\/p>\n    <p><strong>\u58c1\u6302\u7089 = \"\u70e7\u94b1\"\uff1a<\/strong>1m\u00b3\u5929\u7136\u6c14\u224810kWh\u70ed\u503c\uff0c\u4f46\u53d7\u542f\u505c\u6d6a\u8d3920-30%\u5f71\u54cd\uff0c\u5b9e\u9645\u6709\u6548\u70ed\u8f93\u51fa\u4ec57-8.5kWh\/m\u00b3\u3002\u6309\u6210\u90fd\u4e8c\u9636\u68af\u6c14\u4ef72.13\u5143\/m\u00b3\uff0c\u6bcfkWh\u6709\u6548\u70ed\u6210\u672c\u7ea60.25-0.30\u5143\uff0c\u662f\u7a7a\u6c14\u80fd\u76842\u500d\u5de6\u53f3\u3002<\/p>\n  <\/div>\n<\/div>\n\n<!-- \u771f\u5b9e\u6848\u4f8b -->\n<div class=\"section\">\n  <h2>\u771f\u5b9e\u6848\u4f8b\u9a8c\u8bc1 <span style=\"font-size:14px; color:#999; font-weight:400;\">\u9f99\u8109\u5ba2\u6237\u4ece\u9505\u7089\u5347\u7ea7\u5230\u7a7a\u6c14\u80fd<\/span><\/h2>\n\n  <table>\n    <thead><tr><th style=\"width:70px;\">\u5ba2\u6237<\/th><th style=\"width:70px;\">\u6237\u578b<\/th><th>\u539f\u7cfb\u7edf<\/th><th>\u6838\u5fc3\u75db\u70b9<\/th><th>\u65b0\u7cfb\u7edf<\/th><th>\u8282\u80fd\u6548\u679c<\/th><\/tr><\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\" style=\"font-weight:600;\">\u4e07\u8001\u5e08<\/td>\n        <td class=\"ta-left\">\u522b\u5885<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u5a01\u80fd\u666e\u901a\u7089<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">80\u33a1\u5730\u6696\u6708\u8d39 > 1,000\u5143<br>\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u65e5\u7acb\u6c34\u5885\u9002<br>\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b<\/td>\n        <td style=\"color:#27ae60; font-weight:600; font-size:13px;\">\u5730\u6696\u5b63\u8d39\u964d\u81f3<br>400-600\u5143\/\u6708<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\" style=\"font-weight:600;\">\u6768\u54e5<\/td>\n        <td class=\"ta-left\">\u6210\u90fd<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u71c3\u6c14\u58c1\u6302\u7089<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u6708\u5747 > 1,000\u5143<br>\u9505\u7089\u5df2\u6362\u4e24\u6b21<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u65e5\u7acb\u6c34\u5885\u9002<br>\u5929\u6c1f\u5730\u6c34\u4e09\u8054\u4f9b<\/td>\n        <td style=\"color:#27ae60; font-weight:600; font-size:13px;\">\u8fd0\u884c\u8d39\u964d\u81f3<br>400-600\u5143\/\u6708<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\" style=\"font-weight:600;\">\u6881\u603b<\/td>\n        <td class=\"ta-left\">350\u33a1<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u6df7\u88c5\u7cfb\u7edf<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u6708\u71c3\u6c14\u8d39<br>4,500-6,000\u5143<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u5206\u533a\u5206\u7cfb\u7edf<br>\u7a7a\u6c14\u80fd+\u51b7\u51dd\u7089<\/td>\n        <td style=\"color:#27ae60; font-weight:600; font-size:13px;\">\u8fd0\u884c\u8d39\u7701 55%+<br>\u964d\u81f3\u7ea62,000\u5143\/\u6708<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\" style=\"font-weight:600;\">\u8f9b\u603b<\/td>\n        <td class=\"ta-left\">450\u33a1<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u7cfb\u7edf\u4e0d\u7a33\u5b9a<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u80fd\u8017\u9ad8\u3001\u4f53\u611f\u5dee<\/td>\n        <td class=\"ta-left\" style=\"font-size:13px;\">\u51b7\u51dd\u7089+\u6c34\u529b\u5e73\u8861<br>+\u8054\u52a8+\u6c14\u5019\u8865\u507f<\/td>\n        <td style=\"color:#2980b9; font-weight:600; font-size:13px;\">\u4f18\u5316\u6bd4\u6362\u8bbe\u5907<br>\u66f4\u91cd\u8981<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"notice\" style=\"margin-top:16px;\">\n    <strong>\u9f99\u8109\u6570\u636e\uff1a<\/strong>\u4ee5\u4e0a\u6848\u4f8b\u5747\u6765\u81ea\u9f99\u8109\u771f\u5b9e\u5ba2\u6237\u3002\u4ece\u71c3\u6c14\u9505\u7089\u5207\u6362\u5230\u7a7a\u6c14\u80fd\u70ed\u6cf5\u540e\uff0c\u91c7\u6696\u8fd0\u884c\u8d39\u7528\u666e\u904d<strong>\u964d\u4f4e 40-60%<\/strong>\u3002\u66f4\u5173\u952e\u7684\u662f\uff0c\u7a7a\u6c14\u80fd<strong>\u65e0\u9700\u4e2d\u9014\u66f4\u6362\u4e3b\u673a\uff0820\u5e74+ vs 10-15\u5e74\uff09<\/strong>\uff0c20\u5e74\u6301\u6709\u6210\u672c\u4f18\u52bf\u968f\u65f6\u95f4\u63a8\u79fb\u6301\u7eed\u653e\u5927\u3002<br>\n    <span style=\"font-size:13px; color:#666;\">\uff08\u8f9b\u603b\u6848\u4f8b\u8bf4\u660e\uff1a\u5982\u679c\u5ba2\u6237\u575a\u6301\u9009\u62e9\u58c1\u6302\u7089\uff0c\u505a\u597d\u7cfb\u7edf\u4f18\u5316 \u2014 \u6c34\u529b\u5e73\u8861+\u8054\u52a8\u63a7\u5236+\u6c14\u5019\u8865\u507f \u2014 \u6548\u679c\u8fdc\u8d85\u5355\u7eaf\u66f4\u6362\u51b7\u51dd\u7089\uff09<\/span>\n  <\/div>\n<\/div>\n\n<!-- \u9009\u578b\u5efa\u8bae -->\n<div class=\"section\">\n  <h2>\u9009\u578b\u5efa\u8bae <span style=\"font-size:14px; color:#999; font-weight:400;\">\u57fa\u4e8e\u60a8\u7684\u5b9e\u9645\u573a\u666f<\/span><\/h2>\n\n  <div class=\"highlight-box\">\n    <h4>\u60a8\u7684\u573a\u666f\u7279\u5f81<\/h4>\n    <p>198\u33a1\u4e24\u5c42\u522b\u5885 | \u5730\u6696123\u33a1 | \u6210\u90fd\u5730\u533a\uff08\u51ac\u5b63\u6700\u4f4e\u7ea6-3\u2103\uff0c\u5e73\u57475-10\u2103\uff09<\/p>\n    <p>\u5c0a\u777f\u5168\u6548II 180\u578b\u4e00\u62d6\u516d\u7a7a\u8c03\u5df2\u9501\u5b9a | \u4ef7\u683c\u6765\u6e90\uff1a\u9f99\u8109\u6307\u4ee4\u5e93 V5.0 | \u957f\u671f\u81ea\u4f4f<\/p>\n    <p style=\"color:#27ae60; font-weight:600;\">\u6838\u5fc3\u4e8b\u5b9e\uff1a\u65b9\u6848\u4e0020\u5e74\u6301\u6709\u6210\u672c\u4f4e\u7ea630,607\u5143 | \u4e3b\u673a\u5bff\u547d\u8986\u76d6\u5168\u7a0b\u65e0\u9700\u66f4\u6362<\/p>\n  <\/div>\n\n  <table class=\"analysis-table\" style=\"margin-top:16px;\">\n    <thead>\n      <tr><th>\u60a8\u7684\u6838\u5fc3\u8bc9\u6c42<\/th><th>\u63a8\u8350<\/th><th>\u7406\u7531\uff08\u542b20\u5e74\u89c6\u89d2\uff09<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"ta-left\">\u8ffd\u6c42\u957f\u671f\u7701\u94b1\uff08>5\u5e74\uff09<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/td>\n        <td class=\"ta-left\">\u521d\u88c5\u77013,607\u5143 + \u6bcf\u5e74\u91c7\u6696\u7701700\u5143 + \u4e2d\u9014\u65e0\u9700\u6362\u9505\u7089\u770113,000\u5143 = 20\u5e74\u7701\u7ea630,607\u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u8ffd\u6c42\u7cfb\u7edf\u7b80\u6d01\u3001\u4e00\u4f53\u5316\u63a7\u5236<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/td>\n        <td class=\"ta-left\">\u4e00\u5957\u7cfb\u7edf\u7edf\u4e00\u63a7\u5236\u51b7\u3001\u6696\u3001\u65b0\u98ce\uff08\u53ef\u5347\u7ea7\uff09\uff0c\u64cd\u4f5c\u7b80\u4fbf\u65e0\u9700\u5b66\u4e60\u4e24\u5957\u7cfb\u7edf<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u9700\u8981\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53\u5316<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e8c\uff08\u83f2\u65af\u66fc\uff09<\/td>\n        <td class=\"ta-left\">\u58c1\u6302\u7089\u81ea\u5e2624kW\u70ed\u6c34\u3002\u4f46\u6ce8\u610f\uff1a\u4e24\u7528\u7089\u975e\u91c7\u6696\u5b63\"\u70ed\u6c34\u8fc7\u70eb\"\u662f\u901a\u75c5\uff1b\u5982\u9700\u9ad8\u54c1\u8d28\u70ed\u6c34\uff0c\u63a8\u8350\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u5173\u6ce8\u8bbe\u5907\u5bff\u547d\u4e0e\u66f4\u6362\u6210\u672c<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/td>\n        <td class=\"ta-left\">\u5c0a\u777f\u4e3b\u673a20\u5e74+\u65e0\u9700\u66f4\u6362\uff1b\u83f2\u65af\u66fc\u51b7\u51dd\u708910-15\u5e74\u9700\u66f4\u6362\uff08\u7ea613,000\u5143\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u672a\u6765\u5347\u7ea7\u4e94\u6052+<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/td>\n        <td class=\"ta-left\">\u53ef\u65e0\u7f1d\u63a5\u5165\u5929\u51c0\u65b0\u98ce+AI\u96c6\u63a7\u5c4f\uff0c\u5b9e\u73b0\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">\u5e0c\u671b\u7cfb\u7edf\u5197\u4f59\u4fdd\u969c<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e8c\uff08\u83f2\u65af\u66fc\uff09<\/td>\n        <td class=\"ta-left\">\u53cc\u7cfb\u7edf\u72ec\u7acb\uff0c\u4efb\u4e00\u6545\u969c\u4e0d\u5f71\u54cd\u53e6\u4e00\u7cfb\u7edf\u8fd0\u884c\u3002\u4f46\u5c0a\u777f\u6c34\u6a21\u5757\u6545\u969c\u4e5f\u4ec5\u5f71\u54cd\u5730\u6696<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"ta-left\">20\u5e74\u603b\u8d26\u7406\u6027\u51b3\u7b56<\/td>\n        <td class=\"winner\">\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/td>\n        <td class=\"ta-left\" style=\"color:#27ae60; font-weight:600;\">20\u5e74\u603b\u6210\u672c\u7ea613.2\u4e07 vs \u65b9\u6848\u4e8c\u7ea616.3\u4e07\u3002\u6bcf\u591a\u7528\u4e00\u5e74\uff0c\u7701\u5f97\u5c31\u8d8a\u591a<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- \u670d\u52a1\u627f\u8bfa -->\n<div class=\"section\">\n  <h2>\u670d\u52a1\u627f\u8bfa\u4e0e618\u4e13\u5c5e\u6743\u76ca<\/h2>\n  <table>\n    <thead><tr><th style=\"width:180px;\">\u627f\u8bfa\u9879<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td class=\"ta-left\" style=\"font-weight:600;\">\u5b98\u65b9\u6388\u6743\u8d28\u4fdd<\/td><td class=\"ta-left\">\u65e5\u7acb\u4e3b\u673a\u6574\u673a3\u5e74 + \u5c0a\u777f\u538b\u7f29\u673a6\u5e74 + \u5b89\u88c5\u5de5\u827a2\u5e74\uff1b\u83f2\u65af\u66fc\u58c1\u6302\u7089\u5b98\u65b92\u5e74\u8d28\u4fdd<\/td><\/tr>\n      <tr><td class=\"ta-left\" style=\"font-weight:600;\">618\u4e13\u5c5e<\/td><td class=\"ta-left\">19.9\u5143\u5b9a\u91d1\u81a8\u80c0\u62b51,000\u5143 + \u7b7e\u7ea6\u514d\u8d39\u900110\u5e74\u6574\u673a\u8d28\u4fdd<\/td><\/tr>\n      <tr><td class=\"ta-left\" style=\"font-weight:600;\">\u9f99\u8109\u4f1a\u5458<\/td><td class=\"ta-left\">\u7b7e\u7ea6\u6696\u901a\u91d1\u989d\u62b5\u6263\u9996\u5e74\u4f1a\u8d39\uff0c\u524d5\u5e74\u4f1a\u8d39\u5b9e\u4ed80\u5143<\/td><\/tr>\n      <tr><td class=\"ta-left\" style=\"font-weight:600;\">10\u5e74\u80fd\u6e90\u4fdd\u969c<\/td><td class=\"ta-left\">\u7b2c1\/3\/5\/10\u5e74\u5b9a\u671f\u4ea4\u4ed8\u80fd\u8017\u62a5\u544a\u4e0e\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad<\/td><\/tr>\n      <tr><td class=\"ta-left\" style=\"font-weight:600;\">\u4e13\u4e1a\u65bd\u5de5<\/td><td class=\"ta-left\">\u6301\u8bc1\u5b89\u88c5\u5de5\u7a0b\u5e08\uff0c\u65e5\u7acb\u5b98\u65b9\u6807\u51c6\u65bd\u5de5\u89c4\u8303\uff0c\u542b\u7ba1\u8def\u8d70\u5411\u3001\u5185\u673a\u70b9\u4f4d\u89c4\u5212<\/td><\/tr>\n      <tr><td class=\"ta-left\" style=\"font-weight:600;\">\u552e\u540e\u54cd\u5e94<\/td><td class=\"ta-left\">\u6210\u90fd\u672c\u5730\u56e2\u961f\uff0c24\u5c0f\u65f6\u5185\u4e0a\u95e8\uff0cApp\u8fdc\u7a0b\u534f\u52a9<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- \u5ef6\u4f38\u9605\u8bfb -->\n<div class=\"section\">\n  <h2>\u5ef6\u4f38\u9605\u8bfb<\/h2>\n  <p style=\"margin-bottom:12px;\">\u4e86\u89e3\u66f4\u591a\u4ea7\u54c1\u8be6\u60c5\uff1a<\/p>\n  <a class=\"ext-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u5730\u6696\u7cfb\u7edf\u77e5\u8bc6\uff1a\u58c1\u6302\u7089vs\u7a7a\u6c14\u80fd 20\u5e74\u5bf9\u6bd4<\/a>\n  <a class=\"ext-link\" href=\"https:\/\/longmai-nt.com\/guide\/zunrui-shuimokuai.html\" target=\"_blank\">\u5c0a\u777f\u5168\u6548 + \u6c34\u6a21\u5757 \u5929\u6c1f\u5730\u6c34\u8be6\u89e3<\/a>\n  <a class=\"ext-link\" href=\"https:\/\/longmai-nt.com\/?page_id=662\" target=\"_blank\">\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee4\u5e93 V5.0<\/a>\n  <a class=\"ext-link\" href=\"https:\/\/longmai-nt.com\/?page_id=667\" target=\"_blank\">\u5b9e\u6218\u624b\u518c\uff1a\u6c1f\u7cfb\u7edf\u6280\u672f\u53ca\u4e8c\u8054\u4f9b<\/a>\n<\/div>\n\n<!-- FOOTER -->\n<div class=\"footer\">\n  <strong>\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8<\/strong><br>\n  \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u59cb\u4e8e2004\u5e74 \u00b7 \u670d\u52a15000+\u6237\u5bb6\u5ead<br>\n  \u5357\u5bcc\u68ee\u5e97\uff1a028-86131795 \uff5c \u5317\u5bcc\u68ee\u5e97\uff1a028-65272586<br>\n  <a href=\"https:\/\/longmai-nt.com\" target=\"_blank\">longmai-nt.com<\/a><br>\n  <span style=\"opacity:0.6; font-size:12px;\">\u6570\u636e\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee4 V5.0\uff082026.05.23\uff09\uff5c\u5730\u6696\u77e5\u8bc6\u5e93\uff08page_id=1976\uff09\uff5c\u5c0a\u777f\u5168\u6548II\u6298\u62638\u6298 | \u83f2\u65af\u66fc\u58c1\u6302\u70899\u6298 | \u6c34\u6a21\u5757\u4e0d\u6253\u6298 | \u65b9\u6848\u7f16\u53f7\uff1aQ-20260610-LONG-HEAT<\/span>\n<\/div>\n\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u9f99 [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2827","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2827\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u9f99 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2827\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-10T07:07:33+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2827\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2827\",\"name\":\"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-10T07:07:32+00:00\",\"dateModified\":\"2026-06-10T07:07:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2827#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2827\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2827#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2827","og_locale":"zh_CN","og_type":"article","og_title":"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u9f99 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2827","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-10T07:07:33+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2827","url":"https:\/\/longmai-nt.com\/?page_id=2827","name":"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-10T07:07:32+00:00","dateModified":"2026-06-10T07:07:33+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2827#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2827"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2827#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8001\u5e08\u6696\u901a\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2827","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2827"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2827\/revisions"}],"predecessor-version":[{"id":2828,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2827\/revisions\/2828"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2827"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}