{"id":3183,"date":"2026-06-13T19:06:31","date_gmt":"2026-06-13T11:06:31","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=3183"},"modified":"2026-11-10T01:06:56","modified_gmt":"2026-11-09T17:06:56","slug":"%e6%97%a5%e7%ab%8b%e6%b0%b4%e6%a8%a1%e5%9d%97rwmg-160-224-280-335fwxnzq%e5%ae%89%e8%a3%85%e5%8f%8a%e4%bf%9d%e5%85%bb%e8%af%b4%e6%98%8e%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=3183","title":{"rendered":"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66"},"content":{"rendered":"<style>\n\/* ===== Reset & Base ===== *\/\n*, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }\nhtml { font-size: 16px; scroll-behavior: smooth; }\nbody {\n  font-family: \"PingFang SC\", \"Microsoft YaHei\", \"Hiragino Sans GB\", \"Helvetica Neue\", Arial, sans-serif;\n  color: #222; background: #f7f7f9; line-height: 1.8;\n}<\/p>\n<p>\/* ===== Color Palette ===== *\/\n:root {\n  --purple: #534AB7; --coral: #D85A30; --teal: #0F6E56; --blue: #185FA5;\n  --gray-50: #f9f9fc; --gray-100: #efeff4; --gray-200: #d9d9e0; --gray-600: #666; --gray-800: #333;\n  --radius: 8px; --radius-lg: 12px;\n}<\/p>\n<p>\/* ===== Layout ===== *\/\n.wrapper { max-width: 960px; margin: 0 auto; padding: 0 20px; }<\/p>\n<p>\/* Header *\/\n.header {\n  background: linear-gradient(135deg, var(--purple) 0%, #3d35a0 100%);\n  color: #fff; text-align: center; padding: 60px 20px 50px;\n}\n.header .logo { width: 140px; margin-bottom: 24px; }\n.header h1 { font-size: 2rem; font-weight: 700; letter-spacing: 1px; }\n.header .subtitle { font-size: 1.05rem; margin-top: 10px; opacity: 0.85; }\n.header .model-row { margin-top: 18px; font-size: 0.95rem; opacity: 0.8; letter-spacing: 0.5px; }\n.header .doc-id { margin-top: 8px; font-size: 0.85rem; opacity: 0.65; }<\/p>\n<p>\/* Nav *\/\n.nav { background: #fff; border-bottom: 1px solid var(--gray-200); position: sticky; top: 0; z-index: 100; }\n.nav-inner { max-width: 960px; margin: 0 auto; padding: 0 20px; display: flex; flex-wrap: wrap; gap: 6px; }\n.nav a { display: inline-block; padding: 12px 14px; font-size: 0.88rem; color: var(--gray-600); text-decoration: none; border-bottom: 3px solid transparent; transition: all .2s; }\n.nav a:hover { color: var(--purple); border-bottom-color: var(--purple); }<\/p>\n<p>\/* Main *\/\nmain { background: #fff; margin: 24px auto; border-radius: var(--radius-lg); box-shadow: 0 2px 12px rgba(0,0,0,.06); padding: 48px 44px; }\n@media (max-width: 768px) { main { padding: 28px 20px; } }<\/p>\n<p>\/* Typography *\/\nh2 { font-size: 1.55rem; color: var(--purple); margin: 48px 0 16px; padding-bottom: 10px; border-bottom: 2px solid var(--purple); }\nh2:first-of-type { margin-top: 0; }\nh3 { font-size: 1.2rem; color: var(--blue); margin: 32px 0 12px; padding-left: 10px; border-left: 4px solid var(--blue); }\nh4 { font-size: 1.05rem; color: var(--teal); margin: 20px 0 8px; }\np { margin: 8px 0; }\nul, ol { margin: 8px 0 8px 20px; }\nli { margin: 4px 0; }\nstrong { color: var(--coral); }<\/p>\n<p>\/* Alert boxes *\/\n.alert { margin: 16px 0; padding: 14px 18px; border-radius: var(--radius); font-size: 0.94rem; line-height: 1.7; }\n.alert-danger  { background: #fdf2f0; border-left: 5px solid var(--coral); }\n.alert-warning { background: #fff7ee; border-left: 5px solid #e67e22; }\n.alert-caution { background: #f0f7fb; border-left: 5px solid var(--blue); }\n.alert-note    { background: #edf7f3; border-left: 5px solid var(--teal); }\n.alert-tip     { background: #f5f3ff; border-left: 5px solid var(--purple); }\n.alert .label { font-weight: 700; margin-right: 6px; }\n.alert-danger  .label { color: var(--coral); }\n.alert-warning .label { color: #e67e22; }\n.alert-caution .label { color: var(--blue); }\n.alert-note    .label { color: var(--teal); }\n.alert-tip     .label { color: var(--purple); }<\/p>\n<p>\/* Tables *\/\ntable { width: 100%; border-collapse: collapse; margin: 16px 0; font-size: 0.92rem; }\nthead th { background: var(--purple); color: #fff; padding: 10px 12px; text-align: left; font-weight: 600; }\ntbody td { padding: 9px 12px; border-bottom: 1px solid var(--gray-200); }\ntbody tr:nth-child(even) { background: var(--gray-50); }\ntbody tr:hover { background: #f0eef9; }<\/p>\n<p>\/* Images *\/\nfigure { margin: 24px 0; text-align: center; }\nfigure img { max-width: 100%; height: auto; border-radius: var(--radius); box-shadow: 0 2px 10px rgba(0,0,0,.08); }\nfigure figcaption { margin-top: 8px; font-size: 0.88rem; color: var(--gray-600); font-style: italic; }<\/p>\n<p>\/* Two-column image grid *\/\n.img-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 24px; }\n@media (max-width: 640px) { .img-grid { grid-template-columns: 1fr; } }<\/p>\n<p>\/* Spec card *\/\n.spec-card { background: var(--gray-50); border: 1px solid var(--gray-200); border-radius: var(--radius); padding: 16px 20px; margin: 16px 0; }<\/p>\n<p>\/* Page-break-like separator *\/\n.section-sep { border: none; border-top: 1px dashed var(--gray-200); margin: 40px 0; }<\/p>\n<p>\/* Footer *\/\nfooter { text-align: center; padding: 36px 20px; color: var(--gray-600); font-size: 0.85rem; }\nfooter .qr-row { display: flex; justify-content: center; gap: 40px; flex-wrap: wrap; margin: 20px 0; }\nfooter .qr-row figure { margin: 0; }\nfooter .qr-row img { width: 140px; }\nfooter .cert img { width: 500px; max-width: 100%; }<\/p>\n<p>\/* Checklist *\/\n.checklist { list-style: none; margin-left: 0; }\n.checklist li { padding: 4px 0; }\n.checklist li::before { content: \"\u2610 \"; color: var(--purple); font-size: 1.1rem; }<\/p>\n<p>\/* Step number *\/\n.step-num { display: inline-block; width: 26px; height: 26px; line-height: 26px; text-align: center; background: var(--purple); color: #fff; border-radius: 50%; font-size: 0.8rem; font-weight: 700; margin-right: 6px; }\n<\/style>\n<p><!-- ====== HEADER ====== --><\/p>\n<header class=\"header\">\n  <img decoding=\"async\" class=\"logo\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u65e5\u7acb\u54c1\u724c\u6807\u8bc6.jpg\" alt=\"\u65e5\u7acb\u54c1\u724c\u6807\u8bc6\"><\/p>\n<h2>\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66<\/h2>\n<div class=\"subtitle\">\u6c34\u6a21\u5757\u673a\u7ec4 WATER MODULE<\/div>\n<div class=\"model-row\">RWMG-160FWXNZQ \/ RWMG-224FWXNZQ \/ RWMG-280FWXNZQ \/ RWMG-335FWXNZQ<\/div>\n<div class=\"doc-id\">N6010001156 &nbsp;|&nbsp; 2026.01 V01<\/div>\n<\/header>\n<p><!-- ====== NAV ====== --><\/p>\n<nav class=\"nav\">\n<div class=\"nav-inner\">\n  <a href=\"#safety\">\u5b89\u5168\u987b\u77e5<\/a><br \/>\n  <a href=\"#intro\">\u673a\u7ec4\u4ecb\u7ecd<\/a><br \/>\n  <a href=\"#parts\">\u5404\u90e8\u4f4d\u540d\u79f0<\/a><br \/>\n  <a href=\"#pre-run\">\u8fd0\u884c\u4e4b\u524d<\/a><br \/>\n  <a href=\"#trouble\">\u6392\u9664\u7591\u96be<\/a><br \/>\n  <a href=\"#install-prep\">\u5b89\u88c5\u51c6\u5907<\/a><br \/>\n  <a href=\"#install\">\u5b89\u88c5\u6b65\u9aa4<\/a><br \/>\n  <a href=\"#piping\">\u5236\u51b7\u5242\u4e0e\u6c34\u7ba1<\/a><br \/>\n  <a href=\"#water-cycle\">\u6c34\u5faa\u73af<\/a><br \/>\n  <a href=\"#wiring\">\u7535\u6c14\u63a5\u7ebf<\/a><br \/>\n  <a href=\"#ext-pump\">\u5916\u7f6e\u6c34\u6cf5<\/a><br \/>\n  <a href=\"#ext-heat\">\u5916\u7f6e\u7535\u8f85\u70ed<\/a><br \/>\n  <a href=\"#test-run\">\u8bd5\u8fd0\u884c<\/a><br \/>\n  <a href=\"#maintain\">\u7ef4\u62a4\u4fdd\u517b<\/a><br \/>\n  <a href=\"#codes\">\u6545\u969c\u4ee3\u7801<\/a>\n<\/div>\n<\/nav>\n<p><main class=\"wrapper\"><\/p>\n<p><!-- ====== \u91cd\u8981\u4e8b\u9879 ====== --><\/p>\n<h2>\u91cd\u8981\u4e8b\u9879<\/h2>\n<div class=\"alert alert-danger\">\n  <span class=\"label\">\u5371\u9669<\/span>\u4f1a\u9020\u6210\u4e25\u91cd\u4eba\u8eab\u4f24\u5bb3\uff0c\u751a\u81f3\u6709\u5bfc\u81f4\u6b7b\u4ea1\u7684\u76f4\u63a5\u5371\u9669\u6027\u3002\n<\/div>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span>\u53ef\u80fd\u5bfc\u81f4\u4e25\u91cd\u7684\u4eba\u8eab\u4f24\u5bb3\uff0c\u751a\u81f3\u6b7b\u4ea1\u7684\u5371\u9669\u6216\u4e0d\u5b89\u5168\u60c5\u51b5\u3002\n<\/div>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u53ef\u80fd\u5bfc\u81f4\u8f7b\u5ea6\u7684\u4eba\u5458\u53d7\u4f24\u6216\u4ea7\u54c1\u4ee5\u53ca\u8d22\u4ea7\u635f\u5931\u7684\u5371\u5bb3\u6216\u4e0d\u5b89\u5168\u60c5\u51b5\u3002\n<\/div>\n<div class=\"alert alert-note\">\n  <span class=\"label\">\u6ce8<\/span>\u5bf9\u4fdd\u517b\u3001\u7ef4\u4fee\u7684\u63d0\u793a\u548c\u8bf4\u660e\u3002\n<\/div>\n<div class=\"spec-card\">\n  <strong>\u6c34\u6a21\u5757\u8bbe\u8ba1\u6e29\u5ea6\u8303\u56f4<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u6700\u4f4e (\u2103)<\/th>\n<th>\u6700\u9ad8 (\u2103)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5b89\u88c5\u73af\u5883\u6e29\u5ea6<\/td>\n<td>-25<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>\u8fd0\u8f6c\u73af\u5883\u6e29\u5ea6<\/td>\n<td>-25<\/td>\n<td>43<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u70ed\u6c34\u6e29\u5ea6<\/td>\n<td>20<\/td>\n<td>55<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"alert alert-danger\">\n  <span class=\"label\">\u5371\u9669<\/span><\/p>\n<ul>\n<li>\u672a\u9605\u8bfb\u5b89\u88c5\u624b\u518c\uff0c\u7981\u6b62\u8fdb\u884c\u5236\u51b7\u5242\u914d\u7ba1\u8fde\u63a5\u3001\u6392\u6c34\u7ba1\u8fde\u63a5\u3001\u914d\u7ebf\u8fde\u63a5\u7b49\u5b89\u88c5\u5de5\u4f5c\u3002<\/li>\n<li>\u4e25\u7981\u6cfc\u6c34\u8fdb\u5ba4\u5185\u3001\u5ba4\u5916\u673a\uff0c\u672c\u673a\u5668\u5c5e\u4e8e\u7535\u6c14\u4ea7\u54c1\u3002<\/li>\n<li>\u672a\u65ad\u5f00\u4e3b\u7535\u6e90\uff0c\u7981\u6b62\u6253\u5f00\u5ba4\u5185\u5916\u673a\u7684\u7ef4\u4fee\u76d6\u3002<\/li>\n<li>\u5236\u51b7\u5242 R410A \u4e0d\u53ef\u71c3\u3001\u65e0\u6bd2\u3001\u65e0\u81ed\uff0c\u4f46\u63a5\u89e6\u5230\u660e\u706b\u4f1a\u4ea7\u751f\u6709\u6bd2\u6c14\u4f53\uff1b\u8be5\u6c14\u4f53\u6bd4\u7a7a\u6c14\u91cd\uff0c\u5730\u9762\u9644\u8fd1\u5145\u6ee1\u65f6\u53ef\u80fd\u5f15\u53d1\u7f3a\u6c27\u3002<\/li>\n<li>\u53d1\u73b0\u5236\u51b7\u5242\u6cc4\u6f0f\uff0c\u7acb\u5373\u5173\u95ed\u4e3b\u5f00\u5173\u3001\u5207\u65ad\u7535\u6e90\u3001\u901a\u98ce\u3001\u7184\u706d\u660e\u706b\uff0c\u8054\u7cfb\u7ecf\u9500\u5546\u3002<\/li>\n<li>\u4f7f\u7528\u4e2d\u7b49\u611f\u5e94\u901f\u5ea6\u4ee5\u4e0a\u7684 ELB\uff08\u6f0f\u7535\u65ad\u8def\u5668\uff0c\u52a8\u4f5c\u65f6\u95f4 \u22640.1s\uff09\u3002<\/li>\n<li>\u8fd0\u884c\u4e2d\uff0c\u7981\u6b62\u4f7f\u4fdd\u62a4\u88c5\u7f6e\uff08\u5982\u538b\u529b\u5f00\u5173\u7b49\uff09\u77ed\u8def\u3002<\/li>\n<li>\u4e25\u7981\u79c1\u81ea\u89e6\u52a8\u6216\u6539\u52a8\u5ba4\u5185\u5916\u673a\u7684\u5b89\u5168\u88c5\u7f6e\uff0c\u5426\u5219\u6709\u5f15\u53d1\u4e25\u91cd\u4e8b\u6545\u7684\u5371\u9669\u3002<\/li>\n<li>\u8bf7\u52ff\u7528\u624b\u89e6\u6478\u4efb\u4f55\u7535\u6c14\u90e8\u4ef6\uff0c\u53ef\u80fd\u4f1a\u53d1\u751f\u89e6\u7535\u5371\u9669\u3002<\/li>\n<li>\u82e5\u53d1\u751f\u8d77\u706b\uff0c\u5e94\u7b2c\u4e00\u65f6\u95f4\u5207\u65ad\u7535\u6e90\u3002<\/li>\n<li>\u9488\u5bf9\u5b89\u88c5\uff0c\u5fc5\u987b\u5728\u538b\u7f29\u673a\u5f00\u59cb\u8fd0\u884c\u524d\u7262\u56fa\u8fde\u63a5\u5236\u51b7\u5242\u914d\u7ba1\u3002\u9488\u5bf9\u7ef4\u4fee\uff0c\u5fc5\u987b\u5728\u538b\u7f29\u673a\u505c\u6b62\u540e\u5f00\u59cb\u8fc1\u79fb\u3001\u5904\u7406\u548c\u79fb\u9664\u5236\u51b7\u5242\u914d\u7ba1\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span><\/p>\n<ul>\n<li>\u673a\u7ec4\u9644\u8fd1 1 \u7c73\u5185\u7981\u6b62\u4f7f\u7528\u55b7\u96fe\u5242\uff08\u6740\u866b\u5242\u3001\u6cb9\u6f06\u3001\u53d1\u80f6\u7b49\uff09\u3002<\/li>\n<li>\u786e\u4fdd\u63a5\u5730\u7ebf\u7262\u56fa\u8fde\u63a5\uff0c\u7981\u6b62\u63a5\u5728\u7164\u6c14\u7ba1\u3001\u81ea\u6765\u6c34\u7ba1\u3001\u907f\u96f7\u9488\u6216\u7535\u8bdd\u5730\u7ebf\u4e0a\u3002<\/li>\n<li>\u948e\u710a\u65f6\u786e\u4fdd\u65e0\u53ef\u71c3\u6750\u6599\uff1b\u5145\u6ce8\u5236\u51b7\u5242\u65f6\u6234\u76ae\u624b\u5957\u9632\u51bb\u4f24\u3002<\/li>\n<li>\u7262\u56fa\u56fa\u5b9a\u8fde\u63a5\u914d\u7ebf\uff0c\u63a5\u7ebf\u7aef\u5b50\u53d7\u5916\u529b\u53ef\u80fd\u5bfc\u81f4\u677e\u52a8\u3001\u706b\u707e\u3002<\/li>\n<li>\u786e\u4fdd\u5b89\u88c5\u6709\u8db3\u591f\u5f3a\u5ea6\u7684\u56fa\u5b9a\u3002<\/li>\n<li>\u914d\u7ba1\u6216\u914d\u7ebf\u7a7f\u8fc7\u6572\u843d\u5b54\u65f6\uff0c\u5e94\u505a\u597d\u4fdd\u62a4\u9632\u6b62\u5272\u4f24\uff0c\u540c\u65f6\u505a\u597d\u5bc6\u5c01\uff0c\u9632\u6b62\u673a\u7ec4\u8fdb\u6c34\u3001\u8fdb\u866b\u3001\u8001\u9f20\u6216\u5176\u4ed6\u5c0f\u52a8\u7269\u635f\u574f\u914d\u7ebf\u548c\u7535\u5668\u5143\u4ef6\u3002<\/li>\n<li>\u8bf7\u9075\u7167\u5b89\u88c5\u624b\u518c\u548c\u6709\u5173\u7684\u89c4\u5b9a\u3001\u6807\u51c6\u6765\u8fdb\u884c\u7535\u6c14\u65bd\u5de5\u3002<\/li>\n<li>\u987b\u4f7f\u7528\u89c4\u5b9a\u7684\u914d\u7ebf\u548c\u9009\u62e9\u6b63\u786e\u7684\u914d\u7ebf\u3002<\/li>\n<li>\u5728\u4f7f\u7528\u524d\u8bf7\u786e\u4fdd\u5ba4\u5916\u673a\u6ca1\u6709\u88ab\u51b0\u96ea\u8986\u76d6\u3002<\/li>\n<li>\u5982\u679c\u65ad\u8def\u5668\u9891\u7e41\u8d77\u4f5c\u7528\uff0c\u8bf7\u505c\u6b62\u7cfb\u7edf\u8fd0\u884c\uff0c\u8054\u7cfb\u5f53\u5730\u7ecf\u9500\u5546\u6216\u5ba2\u670d\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span><\/p>\n<ul>\n<li>\u7981\u6b62\u8e29\u8e0f\u673a\u5668\u6216\u653e\u7f6e\u6742\u7269\u5728\u673a\u5668\u4e0a\u3002<\/li>\n<li>\u7981\u6b62\u653e\u7f6e\u989d\u5916\u7684\u6750\u6599\u5728\u673a\u5668\u4e0a\u6216\u673a\u5668\u5185\u90e8\u3002<\/li>\n<li>\u8ddd\u79bb\u5f3a\u7535\u78c1\u8f90\u5c04\u6e90\uff08\u5982\u533b\u7597\u8bbe\u5907\uff093 \u7c73\u5185\u7981\u6b62\u5b89\u88c5\u3002<\/li>\n<li>\u5efa\u8bae\u623f\u95f4\u6bcf 3 \u5230 4 \u5c0f\u65f6\u901a\u98ce\u4e00\u6b21\u3002<\/li>\n<li>\u5236\u70ed\u80fd\u529b\u4e0e\u5ba4\u5916\u73af\u5883\u6709\u5173\uff0c\u4f4e\u6e29\u5730\u533a\u5236\u70ed\u80fd\u529b\u4f1a\u6709\u8870\u51cf\u3002<\/li>\n<li>\u8bf7\u52ff\u5c06\u7a7a\u8c03\u5b89\u88c5\u5728\u6709\u6cb9\u98de\u6e85\uff08\u5305\u62ec\u673a\u6cb9\uff09\u3001\u5e26\u6709\u786b\u5316\u6c14\u4f53\u6216\u7845\u5143\u7d20\uff08\u5982\u6e29\u6cc9\uff09\u3001\u6709\u6613\u71c3\u6c14\u4f53\u3001\u6d77\u5cb8\u5730\u5e26\u591a\u76d0\u6027\u6216\u5f3a\u9178\u5f3a\u78b1\u7684\u573a\u6240\uff0c\u5426\u5219\u53ef\u80fd\u5bfc\u81f4\u706b\u707e\u3001\u673a\u5668\u53d8\u5f62\u6216\u6545\u969c\u3002<\/li>\n<li>\u8bf7\u52ff\u4f7f\u673a\u5668\u7684\u51fa\u98ce\u53e3\u76f4\u63a5\u9762\u5bf9\u52a8\u690d\u7269\u3002<\/li>\n<li>\u672c\u7a7a\u8c03\u5b89\u88c5\u53ea\u80fd\u7531\u7ecf\u9500\u5546\u6216\u4e13\u4e1a\u4eba\u5458\u8fdb\u884c\uff0c\u7528\u6237\u81ea\u884c\u5b89\u88c5\u53ef\u80fd\u5f15\u8d77\u6f0f\u6c34\u3001\u89e6\u7535\u6216\u706b\u707e\u3002<\/li>\n<li>\u672c\u7a7a\u8c03\u53ea\u80fd\u4f5c\u4e3a\u666e\u901a\u7a7a\u8c03\u4f7f\u7528\uff0c\u4e0d\u80fd\u7528\u4e8e\u5e72\u71e5\u670d\u88c5\u3001\u51b7\u51bb\u98df\u54c1\u3001\u51b7\u5374\u6216\u52a0\u70ed\u7b49\u5176\u4ed6\u76ee\u7684\u3002<\/li>\n<li>\u672c\u516c\u53f8\u5bf9\u4e8e\u7a7a\u8c03\u673a\u56e0\u5728\u7279\u5b9a\u73af\u5883\u4e2d\u8fd0\u8f6c\u800c\u53d1\u751f\u7684\u5076\u7136\u6027\u635f\u574f\u4e8b\u6545\uff0c\u4e0d\u8d1f\u4efb\u4f55\u8d23\u4efb\u3002<\/li>\n<li>\u4e3a\u4e86\u4fdd\u62a4\u73af\u5883\uff0c\u8bf7\u52ff\u5c06\u4ea7\u54c1\u968f\u610f\u4e22\u5f03\u3002\u672c\u516c\u53f8\u6309\u7167\u56fd\u5bb6\u76f8\u5173\u89c4\u5b9a\u53ef\u63d0\u4f9b\u56de\u6536\u670d\u52a1\u3002<\/li>\n<li>\u672c\u624b\u518c\u5e94\u88ab\u89c6\u4e3a\u7a7a\u8c03\u8bbe\u5907\u7684\u4e00\u90e8\u5206\uff0c\u8bf7\u59a5\u5584\u4fdd\u7ba1\u3002\u672c\u516c\u53f8\u81f4\u529b\u4e8e\u4e0d\u65ad\u5730\u5bf9\u4ea7\u54c1\u8fdb\u884c\u6539\u8fdb\uff0c\u5982\u6709\u53d8\u66f4\u6055\u4e0d\u53e6\u884c\u901a\u77e5\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-note\">\n  <span class=\"label\">\u6ce8<\/span><\/p>\n<ul>\n<li>\u672c\u7a7a\u8c03\u4fdd\u517b\u53ea\u80fd\u7531\u4e13\u4e1a\u7ef4\u4fee\u4eba\u5458\u8fdb\u884c\u3002<\/li>\n<li>\u5efa\u8bae\u623f\u95f4\u6bcf 3 \u5230 4 \u5c0f\u65f6\u901a\u98ce\u4e00\u6b21\u3002<\/li>\n<li>\u70ed\u6cf5\u7a7a\u8c03\u5728\u4e0b\u5217\u60c5\u51b5\u53ef\u80fd\u4e0d\u80fd\u6b63\u5e38\u5de5\u4f5c\uff1a\u7535\u529b\u53d8\u538b\u5668\u53ef\u63d0\u4f9b\u7684\u529f\u7387\u5c0f\u4e8e\u7b49\u4e8e\u7a7a\u8c03\u673a\u7684\u7535\u529f\u7387\uff1b\u5927\u529f\u7387\u7528\u7535\u8bbe\u5907\u4e0e\u7a7a\u8c03\u673a\u7684\u7535\u6e90\u7ebf\u76f8\u9694\u592a\u8fd1\uff0c\u5bfc\u81f4\u7a7a\u8c03\u7684\u7535\u6e90\u7ebf\u4f1a\u4ea7\u751f\u5f88\u5927\u7684\u611f\u5e94\u6d6a\u6d8c\u7535\u538b\u3002<\/li>\n<li>\u6c34\u6a21\u5757\u5236\u70ed\u80fd\u529b\u4e0e\u5ba4\u5916\u73af\u5883\u6709\u5173\uff0c\u5f53\u5ba4\u5916\u673a\u5b89\u88c5\u5728\u4f4e\u6e29\u5730\u533a\u65f6\uff0c\u6c34\u6a21\u5757\u5236\u70ed\u80fd\u529b\u4f1a\u6709\u8870\u51cf\u3002<\/li>\n<\/ul>\n<\/div>\n<h3>\u5230\u8d27\u68c0\u67e5<\/h3>\n<ul>\n<li>\u63a5\u5230\u673a\u5668\u540e\u68c0\u67e5\u662f\u5426\u6709\u8fd0\u8f93\u635f\u4f24\uff0c\u5982\u6709\u5e94\u7acb\u5373\u4e66\u9762\u7533\u62a5\u8fd0\u8f93\u516c\u53f8\u3002<\/li>\n<li>\u68c0\u67e5\u4ea7\u54c1\u578b\u53f7\u3001\u7535\u6c14\u53c2\u6570\uff08\u7535\u6e90\u3001\u7535\u538b\u3001\u9891\u7387\uff09\u53ca\u9644\u4ef6\u662f\u5426\u7b26\u5408\u8981\u6c42\u3002<\/li>\n<li>\u672a\u7ecf\u6d77\u4fe1\u65e5\u7acb\u4e66\u9762\u540c\u610f\u800c\u66f4\u6539\u8bbe\u5907\uff0c\u6d77\u4fe1\u65e5\u7acb\u516c\u53f8\u5c06\u4e0d\u8d1f\u4efb\u4f55\u8d23\u4efb\u3002<\/li>\n<\/ul>\n<hr class=\"section-sep\">\n<h2 id=\"safety\">\u7b2c\u4e00\u90e8\u5206 \u64cd\u4f5c\u624b\u518c<\/h2>\n<h3>1. \u5b89\u5168\u987b\u77e5<\/h3>\n<div class=\"alert alert-danger\">\n  <span class=\"label\">\u5371\u9669<\/span><\/p>\n<ul>\n<li>\u672a\u9605\u8bfb\u5b89\u88c5\u624b\u518c\uff0c\u8bf7\u4e0d\u8981\u8fdb\u884c\u4efb\u4f55\u5b89\u88c5\u5de5\u4f5c\u3002<\/li>\n<li>\u68c0\u6f0f\u53ca\u6c14\u5bc6\u8bd5\u9a8c\u65f6\uff0c\u7981\u6b62\u5145\u5165\u6c27\u6c14\u3001\u4e59\u7094\u6216\u6613\u71c3\u6709\u6bd2\u6c14\u4f53\uff0c\u5efa\u8bae\u7528\u6c2e\u6c14\u3002<\/li>\n<li>\u4e25\u7981\u6cfc\u6c34\u8fdb\u6c34\u6a21\u5757\u3001\u5ba4\u5916\u673a\u3002<\/li>\n<li>\u672a\u65ad\u5f00\u4e3b\u7535\u6e90\uff0c\u7981\u6b62\u6253\u5f00\u6c34\u6a21\u5757\u3001\u5ba4\u5916\u673a\u7684\u7ef4\u4fee\u76d6\u3001\u7535\u8def\u677f\u3002<\/li>\n<li>\u4e25\u7981\u79c1\u81ea\u89e6\u52a8\u6216\u6539\u52a8\u673a\u7ec4\u5185\u7684\u5b89\u5168\u88c5\u7f6e\u3002<\/li>\n<li>\u65bd\u5de5\u548c\u8fd0\u884c\u7cfb\u7edf\u7684\u51b7\u5a92\u5b89\u5168\u6cc4\u6f0f\u91cf\u6807\u51c6\u6839\u636e\u5f53\u5730\u6cd5\u89c4\u6216\u6807\u51c6\u786e\u5b9a\u3002<\/li>\n<li>\u5b89\u88c5\u65f6\u5fc5\u987b\u5728\u538b\u7f29\u673a\u8fd0\u884c\u524d\u7262\u56fa\u8fde\u63a5\u5236\u51b7\u5242\u914d\u7ba1\uff1b\u7ef4\u4fee\u65f6\u5fc5\u987b\u5728\u538b\u7f29\u673a\u505c\u6b62\u540e\u5f00\u59cb\u8fc1\u79fb\u3001\u5904\u7406\u548c\u79fb\u9664\u5236\u51b7\u5242\u914d\u7ba1\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span><\/p>\n<ul>\n<li>\u8bf7\u5c06\u6c34\u6a21\u5757\u5b89\u88c5\u5728\u5ba4\u5185\u8db3\u4ee5\u627f\u53d7\u5176\u91cd\u91cf\u7684\u575a\u5b9e\u4e4b\u5904\u3002<\/li>\n<li>\u8bf7\u52a1\u5fc5\u4f7f\u7528\u89c4\u5b9a\u9644\u4ef6\u548c\u90e8\u4ef6\u5b89\u88c5\u3002<\/li>\n<li>\u4e0d\u8981\u628a\u673a\u7ec4\u5b89\u88c5\u5728\u5b58\u5728\u5927\u91cf\u6cb9\u3001\u84b8\u6c7d\u3001\u6709\u673a\u6eb6\u5242\u548c\u8150\u8680\u6027\u6c14\u4f53\u7684\u573a\u6240\u3002<\/li>\n<li>\u51ac\u5b63\u4e0d\u4f7f\u7528\u65f6\uff0c\u4e0d\u8981\u65ad\u5f00\u6c34\u6a21\u5757\u7684\u7535\u6e90\uff0c\u5173\u673a\u72b6\u6001\u4e0b\u6ee1\u8db3\u6761\u4ef6\u65f6\u673a\u7ec4\u4f1a\u81ea\u52a8\u8fdb\u5165\u9632\u51bb\u5de5\u4f5c\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span><\/p>\n<ul>\n<li>\u957f\u671f\u4e0d\u4f7f\u7528\u65f6\uff0c\u8bf7\u52a1\u5fc5\u62bd\u51fa\u7cfb\u7edf\u4e2d\u7684\u5faa\u73af\u6c34\uff0c\u5426\u5219\u4f1a\u56e0\u51bb\u7ed3\u5bfc\u81f4\u7cfb\u7edf\u635f\u574f\u3002<\/li>\n<li>\u82e5\u4ece\u8c03\u8bd5\u5b8c\u6210\u5230\u7528\u6237\u4f7f\u7528\u95f4\u9694\u8d85\u8fc7 1 \u4e2a\u6708\uff0c\u8bf7\u653e\u51fa\u7cfb\u7edf\u4e2d\u7684\u5faa\u73af\u6c34\u3002<\/li>\n<li>\u7981\u6b62\u5728\u6c34\u8def\u5faa\u73af\u4e2d\u4f7f\u7528\u6d82\u9540\u950c\u7684\u90e8\u4ef6\uff0c\u4f1a\u5bfc\u81f4\u8150\u8680\u3002<\/li>\n<li>\u8bf7\u4f7f\u7528\u81ea\u6765\u6c34\u5e76\u786e\u8ba4\u6c34\u8d28\u975e\u786c\u6027\u3002<\/li>\n<\/ul>\n<\/div>\n<hr class=\"section-sep\">\n<h3 id=\"intro\">2. \u673a\u7ec4\u4ecb\u7ecd<\/h3>\n<p>\u672c\u6c34\u6a21\u5757\u673a\u7ec4\u63d0\u4f9b\u5730\u677f\u91c7\u6696\u7b49\u529f\u80fd\uff0c\u7531\u7ebf\u63a7\u5668\u63a7\u5236\u3002<\/p>\n<table>\n<caption>\u88682.1 \u6c34\u6a21\u5757\u5bb9\u91cf\u8868<\/caption>\n<thead>\n<tr>\n<th>\u6c34\u6a21\u5757\u5bb9\u91cf (10\u00b2W)<\/th>\n<th>\u540d\u4e49\u5236\u51b7\u91cf<\/th>\n<th>\u540d\u4e49\u5236\u70ed\u91cf<\/th>\n<th>\u989d\u5b9a\u7535\u538b<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>160<\/td>\n<td colspan=\"2\" style=\"text-align:center\">16.0 kW<\/td>\n<td>220V<\/td>\n<\/tr>\n<tr>\n<td>224<\/td>\n<td colspan=\"2\" style=\"text-align:center\">22.4 kW<\/td>\n<td>220V<\/td>\n<\/tr>\n<tr>\n<td>280<\/td>\n<td colspan=\"2\" style=\"text-align:center\">28.0 kW<\/td>\n<td>220V<\/td>\n<\/tr>\n<tr>\n<td>335<\/td>\n<td colspan=\"2\" style=\"text-align:center\">33.5 kW<\/td>\n<td>220V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>2.1 \u5730\u677f\u91c7\u6696\u8fd0\u8f6c\u6ce8\u610f\u4e8b\u9879<\/h4>\n<ul>\n<li>\u5236\u70ed\u5b63\u521d\u6b21\u4f7f\u7528\u5730\u677f\u91c7\u6696\u65f6\uff0c\u8bf7\u8fdb\u884c\"\u5730\u677f\u5e72\u71e5\u8fd0\u884c\"\uff0c\u9632\u6b62\u6c34\u6e29\u4e0a\u5347\u8fc7\u5feb\u635f\u574f\u5730\u677f\u3002<\/li>\n<li>\u6c34\u7684\u70ed\u60f0\u6027\u8f83\u5927\uff0c\u5f00\u542f\u540e\u623f\u95f4\u6e29\u5ea6\u53ef\u80fd\u4e0d\u4f1a\u5f88\u5feb\u4e0a\u5347\u3002<\/li>\n<li>\u5ba4\u5916\u6e29\u5ea6\u5f88\u4f4e\u6216\u623f\u95f4\u8d1f\u8377\u5f88\u5927\u65f6\uff0c\u53ef\u5916\u7f6e\u7535\u8f85\u70ed\uff08\u53c2\u7167\u7b2c10\u7ae0\uff09\uff0c\u4f46\u673a\u7ec4\u80fd\u8017\u4f1a\u589e\u52a0\u3002<\/li>\n<\/ul>\n<h4>2.2 \u540c\u65f6\u8fd0\u8f6c\u6ce8\u610f\u4e8b\u9879<\/h4>\n<ul>\n<li>\u7a7a\u8c03\u5236\u70ed\u4e0e\u5730\u6696\u540c\u65f6\u8fd0\u884c\u65f6\uff0c\u7531\u4e8e\u5ba4\u5916\u673a\u5236\u70ed\u80fd\u529b\u4e00\u5b9a\uff0c\u6548\u679c\u4e0d\u5982\u5355\u72ec\u8fd0\u884c\u3002<\/li>\n<li>\u540c\u65f6\u8fd0\u8f6c\u65f6\u7cfb\u7edf\u9ed8\u8ba4\u4f18\u5148\u7a7a\u8c03\u5236\u70ed\u8fd0\u8f6c\u3002<\/li>\n<li>\u540c\u65f6\u8fd0\u8f6c\u65f6\u5730\u6696\u5236\u70ed\u80fd\u529b\u4e0d\u8db3\u4f1a\u81ea\u52a8\u5f00\u542f\u6c34\u6a21\u5757\u7535\u8f85\u70ed\uff08\u5916\u7f6e\u4e14\u8bbe\u5b9a\u6709\u6548\u60c5\u51b5\u4e0b\uff09\uff0c\u80fd\u8017\u53ef\u80fd\u589e\u5927\u3002<\/li>\n<\/ul>\n<h4>2.3 \u5176\u4ed6\u6ce8\u610f\u4e8b\u9879<\/h4>\n<ul>\n<li>\u51ac\u5b63\u957f\u65f6\u95f4\u505c\u673a\u65f6\uff0c\u8bf7\u5c06\u6c34\u6a21\u5757\u548c\u6c34\u7ba1\u8def\u5185\u7684\u6c34\u5168\u90e8\u6392\u51fa\uff0c\u9632\u6b62\u51bb\u7ed3\u3002<\/li>\n<\/ul>\n<hr class=\"section-sep\">\n<h3 id=\"parts\">3. \u5404\u90e8\u4f4d\u540d\u79f0<\/h3>\n<h4>3.1 \u6c34\u6a21\u5757<\/h4>\n<p>\u6c34\u6a21\u5757\u5185\u90e8\u7ed3\u6784\u5982\u4e0b\u56fe\u6240\u793a\u3002<\/p>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u6c34\u6a21\u5757\u5185\u90e8\u6784\u9020\u56fe.jpg\" alt=\"\u6c34\u6a21\u5757\u5185\u90e8\u6784\u9020\u56fe\"><figcaption>\u56fe3.1 \u6c34\u6a21\u5757\u5185\u90e8\u6784\u9020\u56fe<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>\u5e8f\u53f7<\/th>\n<th>\u540d\u79f0<\/th>\n<th>\u5e8f\u53f7<\/th>\n<th>\u540d\u79f0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u81ea\u52a8\u6392\u6c14\u9600<\/td>\n<td>8<\/td>\n<td>\u5165\u6c34\u53e3<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u6c34\u538b\u5f00\u5173<\/td>\n<td>9<\/td>\n<td>\u51fa\u6c34\u53e3<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u5b89\u5168\u9600<\/td>\n<td>10<\/td>\n<td>\u5236\u51b7\u5242\u6db2\u7ba1\u8fde\u63a5<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u81a8\u80c0\u7f50<\/td>\n<td>11<\/td>\n<td>\u5236\u51b7\u5242\u6c14\u7ba1\u8fde\u63a5<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u6c34\u6cf5<\/td>\n<td>12<\/td>\n<td>\u6392\u6c34\u53e3<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>\u7535\u5b50\u81a8\u80c0\u9600<\/td>\n<td>13<\/td>\n<td>\u6c34\u538b\u529b\u8868<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u677f\u5f0f\u6362\u70ed\u5668<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr class=\"section-sep\">\n<h3 id=\"pre-run\">4. \u8fd0\u884c\u4e4b\u524d<\/h3>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span><\/p>\n<ul>\n<li>\u957f\u671f\u672a\u4f7f\u7528\u7684\u673a\u7ec4\uff0c\u5e94\u5728\u542f\u52a8\u524d\u5148\u901a\u7535 1 \u5c0f\u65f6\u4ee5\u4e0a\uff0c\u5207\u52ff\u901a\u7535\u540e\u7acb\u5373\u542f\u52a8\u3002<\/li>\n<li>\u786e\u8ba4\u5ba4\u5916\u673a\u662f\u5426\u88ab\u51b0\u96ea\u8986\u76d6\uff0c\u82e5\u88ab\u76d6\u4f4f\uff0c\u7528\u6e29\u6c34\uff08\u4e0d\u8d85\u8fc7 50\u2103\uff09\u9664\u53bb\u51b0\u96ea\u3002<\/li>\n<li>\u4e0d\u8981\u65ad\u5f00\u6c34\u6a21\u5757\u7684\u7535\u6e90\uff0c\u9632\u6b62\u9632\u9508\u3001\u9632\u83cc\u3001\u9632\u51bb\u529f\u80fd\u5931\u6548\u3002<\/li>\n<li>\u6bcf\u4e2a\u91c7\u6696\u5b63\u8fd0\u884c\u5730\u677f\u91c7\u6696\u524d\uff0c\u5fc5\u987b\u5148\u8fdb\u884c\"\u5730\u677f\u5e72\u71e5\u8fd0\u884c\"\u529f\u80fd\u3002<\/li>\n<li>\u6b63\u786e\u8bbe\u5b9a\u6e29\u5ea6\uff0c\u5236\u70ed\u65f6\u6bd4\u671f\u671b\u503c\u4f4e 2\u2103 \u4ee5\u8282\u7ea6\u80fd\u6e90\u3002<\/li>\n<\/ul>\n<\/div>\n<hr class=\"section-sep\">\n<h3 id=\"trouble\">5. \u6392\u9664\u7591\u96be<\/h3>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5f53\u6c34\u6a21\u5757\u51fa\u73b0\u6f0f\u6c34\u65f6\uff0c\u8bf7\u505c\u6b62\u4f7f\u7528\u5e76\u7acb\u5373\u65ad\u7535\uff0c\u8054\u7cfb\u5f53\u5730\u7ecf\u9500\u5546\u3002\u95fb\u5230\u5f02\u5473\u6216\u770b\u5230\u767d\u8272\u70df\u96fe\u4ece\u673a\u4f53\u4e2d\u5192\u51fa\u65f6\uff0c\u7acb\u5373\u65ad\u7535\u5e76\u8054\u7cfb\u7ecf\u9500\u5546\u3002\n<\/div>\n<h4>5.1 \u82e5\u95ee\u9898\u65e0\u6cd5\u89e3\u51b3<\/h4>\n<p>\u8054\u7cfb\u4ee3\u7406\u5546\u65f6\u8bf4\u660e\uff1a(1) \u673a\u7ec4\u540d\u79f0\u53ca\u578b\u53f7\uff1b(2) \u6545\u969c\u5185\u5bb9\uff1b(3) \u63a7\u5236\u5668\u663e\u793a\u5c4f\u4e0a\u7684\u6545\u969c\u4ee3\u7801\u3002<\/p>\n<h4>5.2 \u6c34\u6a21\u5757\u4e0d\u8fd0\u884c<\/h4>\n<ul>\n<li>\u68c0\u67e5\u6c34\u6cf5\u662f\u5426\u5728\u8fd0\u884c\u3002<\/li>\n<li>\u68c0\u67e5\u8fd0\u884c\u6a21\u5f0f\u548c\u6c34\u6e29\u8bbe\u5b9a\u662f\u5426\u6b63\u786e\u3002<\/li>\n<li>\u68c0\u67e5\u6c34\u7cfb\u7edf\u6392\u6c14\u662f\u5426\u5145\u5206\u3002<\/li>\n<\/ul>\n<h4>5.3 \u5236\u70ed\u80fd\u529b\u4e0d\u8db3<\/h4>\n<ul>\n<li>\u68c0\u67e5\u95e8\u7a97\u662f\u5426\u5f00\u7740\u3002<\/li>\n<li>\u68c0\u67e5\u73af\u5883\u6e29\u5ea6\u662f\u5426\u5728\u8fd0\u884c\u8303\u56f4\u4e4b\u5185\u3002<\/li>\n<\/ul>\n<h4>5.4 \u975e\u6545\u969c\u73b0\u8c61\u89e3\u51b3<\/h4>\n<ul>\n<li>\u957f\u65f6\u95f4\u4f7f\u7528\u540e\uff0c\u6c34\u6a21\u5757\u5468\u56f4\u4f1a\u56e0\u4e3a\u6f6e\u6e7f\u800c\u6ecb\u751f\u7ec6\u83cc\u4ea7\u751f\u9709\u5473\uff0c\u8bf7\u53ca\u65f6\u6e05\u6d17\u5e76\u4fdd\u6301\u826f\u597d\u7684\u901a\u98ce\u73af\u5883\u3002<\/li>\n<li>\u5f53\u673a\u7ec4\u8fd0\u8f6c\u6216\u505c\u6b62\u65f6\uff0c\u60a8\u53ef\u80fd\u4f1a\u542c\u5230\u5236\u51b7\u5242\u6d41\u52a8\u7684\u58f0\u97f3\uff0c\u5c5e\u6b63\u5e38\u73b0\u8c61\u3002<\/li>\n<\/ul>\n<h4>5.5 \u6545\u969c\u89e3\u51b3<\/h4>\n<table>\n<thead>\n<tr>\n<th>NO<\/th>\n<th>\u6545\u969c\u73b0\u8c61<\/th>\n<th>\u68c0\u67e5<\/th>\n<th>\u6392\u9664\u65b9\u6cd5<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u65e0\u663e\u793a\uff0c\u6309\u952e\u65e0\u53cd\u5e94<\/td>\n<td>\u68c0\u67e5\u4e3b\u677f\u6709\u65e0\u4f9b\u7535\uff1b\u68c0\u67e5\u7ebf\u63a7\u5668\u4e0e\u4e3b\u677f\u8fde\u7ebf<\/td>\n<td>\u91cd\u65b0\u4f9b\u7535\uff1b\u66f4\u6362\u901a\u8baf\u7ebf<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u65e0\u663e\u793a\uff0c\u6309\u952e\u6709\u53cd\u5e94<\/td>\n<td>\u68c0\u67e5\u7ebf\u63a7\u5668\u7535\u8def\u677f\u662f\u5426\u6709\u7070\u5c18\u6c61\u67d3\u53ca\u53d7\u6f6e<\/td>\n<td>\u7528\u70ed\u98ce\u67aa\u53ca\u7535\u5439\u98ce\u6392\u9664\u6f6e\u6c14\u53ca\u7070\u5c18<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u6709\u663e\u793a\uff0c\u6309\u952e\u65e0\u53cd\u5e94<\/td>\n<td>\u68c0\u67e5\u901a\u8baf\u7ebf\u662f\u5426\u4e3a\u4e13\u7528\u5c4f\u853d\u7ebf\uff1b\u68c0\u67e5\u7ebf\u63a7\u5668\u4e0e\u4e3b\u677f\u8fde\u7ebf\u7aef\u5b50\u6709\u65e0\u677e\u52a8<\/td>\n<td>\u6362\u4e0a\u5c4f\u853d\u7ebf<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u663e\u793a\u6a21\u7cca<\/td>\n<td>\u68c0\u67e5\u7ebf\u8def\u677f\u662f\u5426\u6709\u7070\u5c18\u6c61\u67d3\u3001\u662f\u5426\u53d7\u6f6e<\/td>\n<td>\u6e05\u7406\u7070\u5c18\uff0c\u7528\u70ed\u98ce\u67aa\u6392\u9664\u6f6e\u6c14<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u80cc\u5149\u4e0d\u4eae<\/td>\n<td>\u68c0\u67e5\u80cc\u5149\u6e90\u7535\u6e90\u7ebf\u6709\u65e0\u65ad\u7ebf<\/td>\n<td>\u91cd\u65b0\u63a5\u7ebf<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>\"03\" \u62a5\u8b66<\/td>\n<td>\u68c0\u67e5\u7ebf\u63a7\u5668\u4e0e\u4e3b\u677f\u8fde\u7ebf\u7aef\u5b50\u6709\u65e0\u677e\u52a8\u3001\u65ad\u7ebf<\/td>\n<td>\u6362\u4e0a\u65b0\u7684\u901a\u8baf\u7ebf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr class=\"section-sep\">\n<h2>\u7b2c\u4e8c\u90e8\u5206 \u5b89\u88c5\u53ca\u4fdd\u517b\u624b\u518c<\/h2>\n<h3>1. \u5b89\u5168\u987b\u77e5<\/h3>\n<p>\u5b89\u88c5\u6c34\u6a21\u5757\u524d\u8bf7\u4ed4\u7ec6\u9605\u8bfb\u6b64\u5b89\u88c5\u8bf4\u660e\u4e66\u5e76\u6309\u7167\u8bf4\u660e\u4e8b\u9879\u8fdb\u884c\u5b89\u88c5\u3002\u5b89\u88c5\u5b8c\u6bd5\u540e\u8fdb\u884c\u8bd5\u8fd0\u8f6c\u3002<\/p>\n<p>\u6c34\u6a21\u5757\u4f7f\u7528\u73af\u5883\u6e29\u5ea6\u5e94\u5728 -25\uff5e43\u2103\uff0c\u63a8\u8350\u5b89\u88c5\u4e8e\u5ba4\u5185\uff1b\u5982\u5b89\u88c5\u4e8e\u5ba4\u5916\uff0c\u5e94\u6ce8\u610f\uff1a\u5b89\u88c5\u4e8e\u9876\u90e8\u6709\u906e\u6321\u7684\u4f4d\u7f6e\uff1b\u51ac\u5b63\u4e0d\u65ad\u7535\uff0c\u65ad\u7535\u5219\u5e94\u6392\u7a7a\u7cfb\u7edf\u4e2d\u7684\u6c34\uff1b\u7ebf\u63a7\u5668\u5e94\u5b89\u88c5\u4e8e\u5ba4\u5185\uff1b\u4e3a\u4e86\u9632\u6b62\u6c34\u7ba1\u8def\u635f\u574f\uff0c\u9700\u8981\u5c06\u6c34\u6a21\u5757\u4e0a\u7684\u6c34\u7ba1\u8def\u9632\u51bb\u673a\u80fd\u9009\u62e9 \"G1\" \u8bbe\u7f6e\u4e3a \"1\" \u6709\u6548\u3002<\/p>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span><\/p>\n<ul>\n<li>\u672a\u9605\u8bfb\u5b89\u88c5\u624b\u518c\uff0c\u8bf7\u4e0d\u8981\u8fdb\u884c\u5236\u51b7\u5242\u7ba1\u8fde\u63a5\u3001\u6c34\u7ba1\u8fde\u63a5\u3001\u7535\u7ebf\u8fde\u63a5\u7b49\u5b89\u88c5\u5de5\u4f5c\u3002<\/li>\n<li>\u68c0\u67e5\u5730\u7ebf\u8fde\u63a5\u662f\u5426\u6b63\u786e\u3001\u7262\u56fa\u3002\u63a5\u76f8\u5e94\u5bb9\u91cf\u7684\u4fdd\u9669\u4e1d\u3002<\/li>\n<li>\u7528\u6237\u4e0d\u53ef\u81ea\u884c\u66f4\u6362\u7535\u6e90\u7ebf\uff0c\u987b\u7531\u4e13\u4e1a\u7ef4\u4fee\u4eba\u5458\u66f4\u6362\u3002<\/li>\n<li>\u672c\u673a\u5668\u4e0d\u9632\u6c34\uff0c\u82e5\u5ba4\u5916\u5b89\u88c5\uff0c\u5fc5\u987b\u6709\u9632\u6c34\u63aa\u65bd\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5728\u8ddd\u79bb\u5f3a\u7535\u78c1\u8f90\u5c04\u6e90\uff08\u5982\u533b\u7597\u8bbe\u5907\uff093 \u7c73\u4ee5\u5185\uff0c\u4e0d\u8981\u5b89\u88c5\u6c34\u6a21\u5757\u3001\u6709\u7ebf\u9065\u63a7\u5668\u548c\u914d\u7ebf\u3002\u5982\u679c\u4f7f\u7528\u9632\u51bb\u6db2\uff0c\u54c1\u724c\u578b\u53f7\u9650\u4e8e\u9676\u6c0f\u5316\u5b66\u3001\u957f\u57ce FD-1 \u6216\u4e2d\u77f3\u5316\u84dd\u661f HEC-\u2161\u3002\u4f7f\u7528\u5176\u4ed6\u9632\u51bb\u6db2\u9700\u5f97\u5230\u672c\u516c\u53f8\u786e\u8ba4\u3002\u52a3\u8d28\u9632\u51bb\u6db2\u4f1a\u5bfc\u81f4\u7cfb\u7edf\u7ba1\u8def\/\u90e8\u4ef6\u8150\u8680\u3001\u673a\u68b0\u6027\u78e8\u635f\u7b49\uff0c\u8fdb\u4e00\u6b65\u53ef\u80fd\u5bfc\u81f4\u6c34\u7cfb\u7edf\u635f\u574f\u3001\u6f0f\u6c34\u3002\u7531\u4e8e\u9632\u51bb\u6db2\u4f7f\u7528\u4e0d\u5f53\u6216\u4f7f\u7528\u52a3\u8d28\u9632\u51bb\u6db2\u5bfc\u81f4\u7684\u635f\u5931\uff0c\u672c\u516c\u53f8\u4e0d\u627f\u62c5\u76f8\u5173\u8d23\u4efb\u3002\n<\/div>\n<h3>2. \u6c34\u6a21\u5757\u90e8\u4ef6\u7b80\u4ecb<\/h3>\n<ul>\n<li><strong>\u6c34\u6cf5<\/strong> \u2014 \u4fdd\u8bc1\u7cfb\u7edf\u4e2d\u6c34\u7684\u5faa\u73af\u6d41\u52a8\u3002<\/li>\n<li><strong>\u5b89\u5168\u9600<\/strong> \u2014 \u4fdd\u8bc1\u7cfb\u7edf\u6c34\u538b\u4e3a 3bar \u4ee5\u4e0b\uff0c\u9632\u6b62\u6c34\u7cfb\u7edf\u538b\u529b\u8fc7\u9ad8\u3002\u5f53\u6c34\u538b\u8d85\u8fc7\u8bbe\u5b9a\u538b\u529b\u65f6\u81ea\u52a8\u6392\u6c34\u3002<\/li>\n<li><strong>\u81a8\u80c0\u7f50<\/strong> \u2014 \u7cfb\u7edf\u5185\u6c34\u70ed\u80c0\u51b7\u7f29\u65f6\u8c03\u8282\u7cfb\u7edf\u6c34\u538b\u529b\u4e0d\u81f3\u4e8e\u8fc7\u9ad8\u6216\u8fc7\u4f4e\uff0c\u907f\u514d\u9891\u7e41\u6392\u6c34\u6216\u8865\u6c34\u3002<\/li>\n<li><strong>\u6392\u6c14\u9600<\/strong> \u2014 \u6392\u9664\u6c34\u7cfb\u7edf\u4e2d\u6b8b\u4f59\u7a7a\u6c14\u3002<\/li>\n<li><strong>\u6c34\u538b\u5f00\u5173<\/strong> \u2014 \u68c0\u6d4b\u7cfb\u7edf\u6c34\u8def\u538b\u529b\uff0c\u4e3a\u6c34\u7cfb\u7edf\u63d0\u4f9b\u4fdd\u62a4\u3002<\/li>\n<li><strong>\u6c34\u8fc7\u6ee4\u5668<\/strong> \u2014 \u8fc7\u6ee4\u6c34\u4e2d\u6742\u8d28\uff0c\u4ee5\u514d\u635f\u574f\u3001\u5835\u585e\u6c34\u6cf5\u6216\u677f\u5f0f\u6362\u70ed\u5668\u3002\u5e94\u5b9a\u671f\u6e05\u7406\u3002<\/li>\n<\/ul>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u8bf7\u52a1\u5fc5\u7528\u4e8e\u73b0\u573a\u5b89\u88c5\uff0c\u5426\u5219\u4f1a\u5bfc\u81f4\u673a\u7ec4\u65e0\u6cd5\u6b63\u5e38\u8fd0\u8f6c\u3002\u7981\u6b62\u5c06\u5730\u6696\u70ed\u6cf5\u6c34\u6a21\u5757\u673a\u7ec4\u7528\u4e8e\u53e6\u4e00\u79cd\u70ed\u6e90\u7cfb\u5217\uff08\u5982\u71c3\u6c14\u7089\uff09\u4e2d\u3002\n<\/div>\n<h3>3. \u5b89\u88c5\u6240\u9700\u7684\u5de5\u5177\u53ca\u4eea\u5668<\/h3>\n<p>\u6838\u67e5\u673a\u5668\u7684\u8bbe\u8ba1\u538b\u529b\u4e3a 4.3MPa\u3002\u5728\u8fdb\u884c\u5b89\u88c5\u65bd\u5de5\u65f6\uff0c\u6709\u5fc5\u8981\u51c6\u5907\u5982\u4e0b\u5de5\u5177\uff1a<\/p>\n<table>\n<thead>\n<tr>\n<th>\u7f16\u53f7<\/th>\n<th>\u5de5\u5177<\/th>\n<th>\u7f16\u53f7<\/th>\n<th>\u5de5\u5177<\/th>\n<th>\u7f16\u53f7<\/th>\n<th>\u5de5\u5177<\/th>\n<th>\u7f16\u53f7<\/th>\n<th>\u5de5\u5177<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u624b\u952f<\/td>\n<td>6<\/td>\n<td>\u5f2f\u7ba1\u673a<\/td>\n<td>11<\/td>\n<td>\u6273\u624b<\/td>\n<td>16<\/td>\n<td>\u6c34\u5e73\u4eea<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u87ba\u4e1d\u5200<\/td>\n<td>7<\/td>\n<td>\u8001\u864e\u94b3<\/td>\n<td>12<\/td>\n<td>\u5145\u6db2\u7f50<\/td>\n<td>17<\/td>\n<td>\u7ebf\u5934\u54ac\u5408\u5668<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u771f\u7a7a\u6cf5<\/td>\n<td>8<\/td>\n<td>\u5207\u7ba1\u673a<\/td>\n<td>13<\/td>\n<td>\u8c03\u8282\u9600<\/td>\n<td>18<\/td>\n<td>\u5347\u964d\u673a<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u5145\u6ce8\u5bfc\u7ba1<\/td>\n<td>9<\/td>\n<td>\u948e\u710a\u5de5\u5177<\/td>\n<td>14<\/td>\n<td>\u5207\u7ebf\u5668<\/td>\n<td>19<\/td>\n<td>\u7535\u6d41\u8ba1<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u5146\u6b27\u8868<\/td>\n<td>10<\/td>\n<td>\u516d\u89d2\u6273\u624b<\/td>\n<td>15<\/td>\n<td>\u68c0\u6f0f\u4eea<\/td>\n<td>20<\/td>\n<td>\u7535\u538b\u8ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5173\u4e8e\u771f\u7a7a\u6cf5\u3001\u5236\u51b7\u5242\u7ba1\u9053\u3001\u5145\u6db2\u7f50\u3001\u591a\u529f\u80fd\u6d4b\u91cf\u4eea\uff0c\u8bf7\u4f7f\u7528\u4e13\u7528\u4e8e R410A \u7684\u8bbe\u5907\uff0c\u52ff\u548c\u5176\u5b83\u5236\u51b7\u5242\u8bbe\u5907\u6df7\u7528\u3002\n<\/div>\n<div class=\"alert alert-danger\">\n  <span class=\"label\">\u5371\u9669<\/span>\u5236\u51b7\u5242 R410A \u7684\u8bbe\u8ba1\u538b\u529b\u4e3a 4.3MPa\uff0c\u5fc5\u987b\u4f7f\u7528\u6307\u5b9a\u7684\u6750\u6599\u3001\u5de5\u5177\uff0c\u5426\u5219\u53ef\u80fd\u5bfc\u81f4\u7206\u70b8\u3001\u4eba\u8eab\u635f\u4f24\u3002\u6c34\u5206\u3001\u6c27\u5316\u76ae\u3001\u6cb9\u8102\u7b49\u6742\u8d28\u5f88\u5bb9\u6613\u5f71\u54cd\u5236\u51b7\u5242\u6027\u80fd\uff0c\u5fc5\u987b\u53bb\u9664\u5236\u51b7\u7cfb\u7edf\u4e2d\u7684\u6c34\u4efd\u3001\u7070\u5c18\u7b49\u5176\u4ed6\u5236\u51b7\u5242\u6216\u51b7\u51bb\u673a\u6cb9\u3002\n<\/div>\n<h3>4. \u8fd0\u8f93\u548c\u642c\u8fd0<\/h3>\n<h4>4.1 \u8fd0\u8f93<\/h4>\n<ul>\n<li>\u6c34\u6a21\u5757\u5e94\u5305\u88c5\u5728\u7eb8\u677f\u7bb1\u5185\u8fd0\u8f93\u3002\u4e3a\u907f\u514d\u8fd0\u8f93\u4e2d\u635f\u574f\uff0c\u8bf7\u5728\u5b89\u88c5\u4e4b\u524d\u518d\u6253\u5f00\u7eb8\u7bb1\u3002<\/li>\n<li>\u5728\u62c6\u7bb1\u524d\u628a\u673a\u5668\u8fd0\u8f93\u5230\u79bb\u5b89\u88c5\u5730\u70b9\u5c3d\u53ef\u80fd\u8fd1\u7684\u5730\u65b9\u3002<\/li>\n<\/ul>\n<h4>4.2 \u642c\u8fd0<\/h4>\n<ul>\n<li>\u6c34\u6a21\u5757\u9700\u8981\u4e24\u4e2a\u4eba\u6216\u591a\u4eba\u642c\u8fd0\u4e0e\u653e\u7f6e\u673a\u7ec4\u3002<\/li>\n<li>\u642c\u8fd0\u65f6\u8bf7\u6234\u624b\u5957\u505a\u597d\u9632\u62a4\uff0c\u4e25\u7981\u62c6\u9664\u6728\u5e95\u6258\u3002<\/li>\n<li>\u642c\u8fd0\u65f6\u8bf7\u505a\u597d\u673a\u7ec4\u8868\u9762\u7684\u9632\u62a4\u63aa\u65bd\uff0c\u4e0d\u8981\u63e1\u4f4f\u914d\u7ba1\u3001\u9762\u677f\u7b49\u90e8\u5206\u3002<\/li>\n<\/ul>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u673a\u5668\u5916\u5305\u88c5\u7eb8\u677f\u5f3a\u5ea6\u6709\u9650\uff0c\u4e25\u7981\u8e29\u8e0f\u673a\u5668\u5305\u88c5\uff0c\u4e25\u7981\u5728\u673a\u5668\u4e0a\u653e\u7f6e\u4efb\u4f55\u6750\u6599\u3002\n<\/div>\n<hr class=\"section-sep\">\n<p><!-- ====== 5. \u6c34\u6a21\u5757\u7684\u5b89\u88c5 ====== --><\/p>\n<h2 id=\"install-prep\">5. \u6c34\u6a21\u5757\u7684\u5b89\u88c5<\/h2>\n<h3>5.1 \u968f\u673a\u9644\u4ef6<\/h3>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span>\u5728\u5b89\u88c5\u8c03\u8bd5\u4e4b\u524d\uff0c\u6c34\u6a21\u5757\u5185\u4e0d\u8981\u653e\u4efb\u4f55\u65e0\u5173\u6750\u6599\uff0c\u786e\u4fdd\u673a\u5185\u65e0\u6742\u7269\uff0c\u5426\u5219\u53ef\u80fd\u53d1\u751f\u706b\u707e\u6216\u4e8b\u6545\u3002\n<\/div>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5982\u679c\u9644\u4ef6\u672a\u968f\u673a\u88c5\u8fd0\uff0c\u8bf7\u4e0e\u7ecf\u9500\u5546\u8054\u7cfb\u3002\n<\/div>\n<table>\n<caption>\u88685.1 \u968f\u673a\u9644\u4ef6<\/caption>\n<thead>\n<tr>\n<th>NO<\/th>\n<th>\u540d\u79f0<\/th>\n<th>\u6570\u91cf<\/th>\n<th>\u5907\u6ce8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u968f\u673a\u8bf4\u660e\u4e66<\/td>\n<td>1<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u6c34\u8def\u7403\u9600<\/td>\n<td>1<\/td>\n<td>\u8fde\u63a5\u5728\u6c34\u6a21\u5757\u51fa\u6c34\u4fa7\uff0c\u7528\u4e8e\u5173\u65ad\u6c34\u6a21\u5757\u6c34\u8def\u3001\u6392\u6c34\u3001\u6ce8\u6c34\u7b49<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u6a61\u80f6\u57ab\u7247<\/td>\n<td>2<\/td>\n<td>\u6c34\u6a21\u5757\u548c\u7403\u9600\u4e4b\u95f4\u8fde\u63a5\u65f6\u5bc6\u5c01\u7528<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u6c34\u8fc7\u6ee4\u5668\u7403\u9600<\/td>\n<td>1<\/td>\n<td>\u8fde\u63a5\u5728\u6c34\u6a21\u5757\u8fdb\u6c34\u4fa7\uff0c\u7528\u4e8e\u5173\u65ad\u6c34\u6a21\u5757\u6c34\u8def\u3001\u6392\u6c34\u3001\u6ce8\u6c34\u3001\u8fc7\u6ee4\u6742\u8d28\u7b49<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u6302\u677f<\/td>\n<td>1<\/td>\n<td>\u6302\u7f6e\u6c34\u6a21\u5757\u673a\u7ec4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"img-grid\">\n<figure>\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u968f\u673a\u9644\u4ef6-\u6302\u677f\u5c3a\u5bf8\u56fe.jpg\" alt=\"\u968f\u673a\u9644\u4ef6-\u6302\u677f\u5c3a\u5bf8\u56fe\"><figcaption>\u56fe\uff1a\u968f\u673a\u9644\u4ef6 \u2014 \u6302\u677f\u5c3a\u5bf8\u56fe<\/figcaption><\/figure>\n<figure>\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u968f\u673a\u9644\u4ef6-\u7403\u9600\u8fc7\u6ee4\u5668\u56fe\u793a.jpg\" alt=\"\u968f\u673a\u9644\u4ef6-\u7403\u9600\u8fc7\u6ee4\u5668\u56fe\u793a\"><figcaption>\u56fe\uff1a\u968f\u673a\u9644\u4ef6 \u2014 \u7403\u9600\u8fc7\u6ee4\u5668\u56fe\u793a<\/figcaption><\/figure>\n<\/div>\n<table style=\"margin-top:16px;\">\n<caption>\u88685.2 \u9009\u914d\u4ef6<\/caption>\n<thead>\n<tr>\n<th>NO<\/th>\n<th>\u540d\u79f0<\/th>\n<th>\u6570\u91cf<\/th>\n<th>\u5907\u6ce8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u6709\u7ebf\u9065\u63a7\u5668<\/td>\n<td>1<\/td>\n<td>\u578b\u53f7\u4e3a PC-WMH30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 id=\"install\">5.2 \u521d\u671f\u68c0\u67e5<\/h3>\n<p>\u5c06\u6c34\u6a21\u5757\u5b89\u88c5\u5728\u6613\u4e8e\u64cd\u4f5c\u53ca\u7ef4\u62a4\u7684\u7a7a\u95f4\u4f4d\u7f6e\u3002\u5b89\u88c5\u5730\u70b9\u9009\u62e9\uff1a\u5ba4\u5185\u6216\u5ba4\u5916\uff08\u4e13\u7528\u673a\u623f\u3001\u5c01\u95ed\u9633\u53f0\u3001\u5730\u4e0b\u5ba4\u3001\u8d70\u5eca\u3001\u8bbe\u5907\u95f4\u7b49\u5ba4\u5185\u533a\u57df\uff0c\u6216\u5f00\u653e\u9633\u53f0\u7b49\u9876\u90e8\u6709\u906e\u6321\u7684\u5ba4\u5916\uff09\u3002\u5b89\u88c5\u8868\u9762\u5fc5\u987b\u662f\u5e73\u5766\u3001\u5782\u76f4\u3001\u4e0d\u53ef\u71c3\u7684\u5899\u9762\uff0c\u4e14\u80fd\u591f\u627f\u53d7\u673a\u7ec4\u8fd0\u8f6c\u91cd\u91cf\u3002<\/p>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u6c34\u6a21\u5757\u5916\u5f62\u5c3a\u5bf8\u56fe.jpg\" alt=\"\u6c34\u6a21\u5757\u5916\u5f62\u5c3a\u5bf8\u56fe\"><figcaption>\u56fe5.1 \u6c34\u6a21\u5757\u5916\u5f62\u5c3a\u5bf8\u56fe\uff08\u5355\u4f4d\uff1amm\uff09<\/figcaption><\/figure>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u5b89\u88c5\u4e0e\u7ef4\u62a4\u7a7a\u95f4\u8981\u6c42\u56fe.jpg\" alt=\"\u5b89\u88c5\u4e0e\u7ef4\u62a4\u7a7a\u95f4\u8981\u6c42\u56fe\"><figcaption>\u56fe5.2 \u5b89\u88c5\u4e0e\u7ef4\u62a4\u7a7a\u95f4\u8981\u6c42\u56fe\uff08\u7ea2\u8272\u533a\u57df\u8868\u793a\u7ef4\u4fee\u7a7a\u95f4\uff0c\u5355\u4f4d\uff1amm\uff09<\/figcaption><\/figure>\n<ul>\n<li>\u6c34\u6a21\u5757\u5e94\u5b89\u88c5\u4e8e\u9634\u51c9\u5904\uff0c\u907f\u514d\u9633\u5149\u76f4\u5c04\u6216\u9ad8\u6e29\u70ed\u6e90\u76f4\u63a5\u8f90\u5c04\u3002<\/li>\n<li>\u5b89\u88c5\u4f4d\u7f6e\u73af\u5883\u6e29\u5ea6\u5728 -25\uff5e60\u2103 \u4e4b\u95f4\uff0c\u76f8\u5bf9\u6e7f\u5ea6\u4e0d\u8d85\u8fc7 80%\u3002<\/li>\n<li>\u6c34\u6a21\u5757\u5e94\u7f6e\u4e8e\u65e0\u9178\u3001\u78b1\u6027\u7b49\u8150\u8680\u6027\u6c14\u4f53\u7684\u5730\u65b9\u3002<\/li>\n<li>\u4e0d\u8981\u5b89\u88c5\u4e8e\u9ad8\u6cb9\u6c61\u3001\u7ea4\u7ef4\u3001\u7c89\u5c18\u3001\u6325\u53d1\u6027\u6613\u71c3\u6c14\u4f53\u5982\u6c7d\u6cb9\u3001\u6cb9\u6f06\u6eb6\u5242\u7b49\u5730\u70b9\u3002<\/li>\n<li>\u4e0d\u8981\u5b89\u88c5\u4e8e\u7535\u78c1\u6ce2\u53ef\u76f4\u63a5\u8f90\u5c04\u5230\u7535\u6c14\u76d2\u7684\u5730\u65b9\u3002\u5c3d\u91cf\u8fdc\u79bb\u7535\u78c1\u6ce2\u8f90\u5c04\uff0c\u81f3\u5c11 3m \u4ee5\u4e0a\u3002<\/li>\n<li>\u6c34\u6a21\u5757\u7684\u566a\u97f3\u5e94\u4e0d\u5f71\u54cd\u4eba\u5458\u8d77\u5c45\u3001\u529e\u516c\u7b49\u3002<\/li>\n<\/ul>\n<h3>5.3 \u5b89\u88c5\u6c34\u6a21\u5757<\/h3>\n<h4>5.3.1 \u68c0\u67e5\u3001\u6253\u5f00\u6c34\u6a21\u5757<\/h4>\n<p>\u4ece\u6c34\u6a21\u5757\u80cc\u9762\u62c6\u4e0b\"\u652f\u67b6\"\u3002\u5916\u7f69\u58f3\u4e3a\u5206\u4f53\u5f0f\u7ed3\u6784\uff0c\u68c0\u4fee\u673a\u5668\u65f6\u53ef\u4ec5\u5c06\u7ef4\u4fee\u9876\u76d6\u5411\u4e0a\u63d0\u62c9\u53d6\u4e0b\u3002\u6253\u5f00\u6c34\u6a21\u5757\u524d\u677f\u7684\u4e0b\u4fa7\u76d6\u677f\uff08\u76d6\u677f\u4f9d\u9760\u78c1\u94c1\u56fa\u5b9a\uff09\uff0c\u53ef\u89c1\u7ebf\u63a7\u5668\u5b89\u88c5\u5b54\u3002<\/p>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u5916\u7f69\u58f3\u62c6\u5378\u793a\u610f\u56fe.jpg\" alt=\"\u5916\u7f69\u58f3\u62c6\u5378\u793a\u610f\u56fe\"><figcaption>\u56fe\uff1a\u5916\u7f69\u58f3\u62c6\u5378\u793a\u610f\u56fe<\/figcaption><\/figure>\n<h4>5.3.2 \u5b89\u88c5\u6c34\u6a21\u5757<\/h4>\n<p>\u5b89\u88c5\u5899\u9762\u52a1\u5fc5\u80fd\u627f\u53d7\u4f4f\u6c34\u6a21\u5757\u8fd0\u8f6c\u91cd\u91cf\u3002\u6c34\u6a21\u5757\u524d\u540e\u5de6\u53f3\u4e0d\u503e\u659c\uff0c\u8fd0\u884c\u65f6\u65e0\u5f02\u5e38\u632f\u52a8\u3001\u566a\u97f3\u3002\u5c06\u6c34\u6a21\u5757\u60ac\u6302\u81f3\u652f\u67b6\u4e0a\u3002\u5982\u6709\u7279\u6b8a\u539f\u56e0\u4e0d\u80fd\u4fdd\u8bc1\u5782\u76f4\u4e8e\u5730\u9762\u5b89\u88c5\uff0c\u52a1\u5fc5\u4f7f\u503e\u659c\u65b9\u5411\u503e\u5411\u51dd\u6c34\u53e3\u5904\uff0c\u503e\u89d2 \u22642\u00b0\u3002<\/p>\n<div class=\"img-grid\">\n<figure>\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4-\u6302\u5899\u56fa\u5b9a.jpg\" alt=\"\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4-\u6302\u5899\u56fa\u5b9a\"><figcaption>\u56fe\uff1a\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4 \u2014 \u6302\u5899\u56fa\u5b9a<\/figcaption><\/figure>\n<\/div>\n<div class=\"img-grid\">\n<figure>\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4-\u5e95\u90e8\u56fa\u5b9a.jpg\" alt=\"\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4-\u5e95\u90e8\u56fa\u5b9a\"><figcaption>\u56fe\uff1a\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4 \u2014 \u5e95\u90e8\u56fa\u5b9a<\/figcaption><\/figure>\n<\/div>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4-\u5378\u6728\u5e95\u6258.jpg\" alt=\"\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4-\u5378\u6728\u5e95\u6258\"><figcaption>\u56fe\uff1a\u58c1\u6302\u5b89\u88c5\u6b65\u9aa4 \u2014 \u5378\u6728\u5e95\u6258<\/figcaption><\/figure>\n<div class=\"alert alert-tip\">\n  <span class=\"label\">\u5b89\u88c5\u6b65\u9aa4\u603b\u7ed3<\/span><\/p>\n<ol>\n<li>\u5c06\u652f\u67b6\u7528 2 \u9897\u81a8\u80c0\u87ba\u6813\u6c34\u5e73\u5b89\u88c5\u81f3\u5899\u9762<\/li>\n<li>\u5c06\u6c34\u6a21\u5757\u60ac\u6302\u81f3\u652f\u67b6\u4e0a<\/li>\n<li>\u7528 2 \u9897 M8 \u7684\u81a8\u80c0\u87ba\u6813\u901a\u8fc7\u5e95\u677f\u5916\u7f18\u4e0a\u7684\u4e24\u4e2a\u5b54\u5c06\u6c34\u6a21\u5757\u5e95\u90e8\u56fa\u5b9a<\/li>\n<\/ol>\n<\/div>\n<hr class=\"section-sep\">\n<p><!-- ====== 6. \u5236\u51b7\u5242\u53ca\u6c34\u8def\u7ba1\u9053 ====== --><\/p>\n<h2 id=\"piping\">6. \u5236\u51b7\u5242\u53ca\u6c34\u8def\u7ba1\u9053<\/h2>\n<div class=\"alert alert-danger\">\n  <span class=\"label\">\u5371\u9669<\/span>\u5728\u5236\u51b7\u56de\u8def\u4e2d\u5145\u6ce8\u5236\u51b7\u5242 R410A\u3002\u68c0\u6f0f\u53ca\u6c14\u5bc6\u6027\u8bd5\u9a8c\u65f6\uff0c\u4e0d\u8981\u6df7\u5165\u6c27\u6c14\u3001\u4e59\u7094\u548c\u6613\u71c3\u3001\u6709\u6bd2\u6c14\u4f53\uff0c\u5efa\u8bae\u7528\u6c2e\u6c14\u505a\u8fd9\u4e9b\u8bd5\u9a8c\u3002\n<\/div>\n<h3>6.1 \u5236\u51b7\u5242\u7ba1\u9053\u7ba1\u6750<\/h3>\n<p>\u94dc\u7ba1\u5728\u73b0\u573a\u7b79\u5907\uff0c\u6309\u4e0b\u8868\u9009\u7ba1\u5c3a\u5bf8\uff1a<\/p>\n<table>\n<thead>\n<tr>\n<th>\u5bb9\u91cf (10\u00b2W)<\/th>\n<th>\u6c14\u7ba1<\/th>\n<th>\u6db2\u7ba1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>160 \/ 224<\/td>\n<td>\u03a615.88<\/td>\n<td>\u03a69.53<\/td>\n<\/tr>\n<tr>\n<td>280 \/ 335<\/td>\n<td>\u03a619.05<\/td>\n<td>\u03a612.7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u9009\u62e9\u7ba1\u5185\u65e0\u5c18\u65e0\u6f6e\u6c14\u7684\u94dc\u7ba1\u3002\u7ba1\u9053\u5b89\u88c5\u524d\uff0c\u7528\u6c2e\u6c14\u6216\u5e72\u71e5\u7a7a\u6c14\u5439\u9664\u7ba1\u9053\u5185\u7070\u5c18\u53ca\u6742\u8d28\u3002<\/p>\n<h3>6.2 \u5236\u51b7\u5242\u7ba1\u9053\u7684\u8fde\u63a5<\/h3>\n<ol>\n<li>\u786e\u8ba4\u622a\u6b62\u9600\u5df2\u5173\u95ed\u3002<\/li>\n<li>\u948e\u710a\u5f2f\u5934\u548c\u73b0\u573a\u7b79\u5907\u7684\u7ba1\u9053\u3002<\/li>\n<li>\u7528\u4e24\u4e2a\u6273\u624b\u62e7\u7d27\u7eb3\u5b50\u5e3d\uff0c\u53c2\u8003\u4e0b\u8868\u529b\u77e9\u8981\u6c42\u3002<\/li>\n<\/ol>\n<table>\n<thead>\n<tr>\n<th>\u7ba1\u5f84<\/th>\n<th>\u626d\u77e9 (N\u00b7m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u03a69.53<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>\u03a612.7<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>\u03a615.88<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>\u03a619.05<\/td>\n<td>100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u5236\u51b7\u5242\u7ba1\u8fde\u63a5-\u62e7\u7d27\u7eb3\u5b50\u5e3d.jpg\" alt=\"\u5236\u51b7\u5242\u7ba1\u8fde\u63a5-\u62e7\u7d27\u7eb3\u5b50\u5e3d\"><figcaption>\u56fe6.1 \u5236\u51b7\u5242\u7ba1\u9053\u8fde\u63a5 \u2014 \u62e7\u7d27\u7eb3\u5b50\u5e3d<\/figcaption><\/figure>\n<p><strong>\u5236\u51b7\u5242\u7ba1\u7684\u4fdd\u6e29\uff1a<\/strong>\u63a5\u7ba1\u540e\u5e94\u91c7\u7528\u73b0\u573a\u4fdd\u6e29\u6750\u6599\u5c06\u6c14\u7ba1\u3001\u6db2\u7ba1\u53ca\u68c0\u6d4b\u63a5\u5934\u3001\u63a5\u5934\u87ba\u6bcd\u7b49\u8fde\u63a5\u90e8\u4f4d\u4fdd\u6e29\uff0c\u5e76\u5e94\u7528\u80f6\u5e26\u5305\u7f20\u5916\u8868\uff0c\u4ee5\u9632\u6563\u70ed\u548c\u7ba1\u9053\u8868\u9762\u51b7\u51dd\u3002<\/p>\n<p><strong>\u5236\u51b7\u5242\u5145\u6ce8\u4e0e\u6392\u653e\uff1a<\/strong>\u6309\u5ba4\u5916\u673a\u7684\u5b89\u88c5\u4fdd\u517b\u624b\u518c\u64cd\u4f5c\u3002<\/p>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5f53\u7ba1\u7a7f\u8fc7\u5b54\u6d1e\u65f6\uff0c\u8981\u7528\u5c01\u5e3d\u5835\u4f4f\u7ba1\u5934\u3002\u5728\u7ba1\u7aef\u90e8\u7528\u5c01\u5e3d\u6216\u7528\u80f6\u5e26\u5c01\u5835\uff0c\u4e0d\u8981\u76f4\u63a5\u653e\u5728\u5730\u4e0a\u3002\n<\/div>\n<h3>6.3 \u6c34\u7ba1\u9053\u7684\u8fde\u63a5<\/h3>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u6c34\u7ba1\u9053\u8fde\u63a5\u4f4d\u7f6e\u793a\u610f\u56fe.jpg\" alt=\"\u6c34\u7ba1\u9053\u8fde\u63a5\u4f4d\u7f6e\u793a\u610f\u56fe\"><figcaption>\u56fe6.2 \u6c34\u7ba1\u9053\u8fde\u63a5\u4f4d\u7f6e\u793a\u610f\u56fe<\/figcaption><\/figure>\n<h4>\u6c34\u7ba1\u8fde\u63a5\u6ce8\u610f\u4e8b\u9879<\/h4>\n<ul>\n<li>\u8bf7\u6ce8\u610f\u63a5\u7ba1\u4f4d\u7f6e\uff0c\u4e0d\u8981\u5c06\u8fdb\u3001\u51fa\u6c34\u7ba1\u63a5\u53cd\u3002<\/li>\n<li>\u4f7f\u7528\u7b26\u5408\u5f53\u5730\u6216\u56fd\u5bb6\u6cd5\u89c4\u7684\u6c34\u7ba1\uff0c\u6c34\u7ba1\u5c3a\u5bf8\u7b49\u4e8e\u6216\u5927\u4e8e\u6c34\u6a21\u5757\u4e0a\u63a5\u53e3\u5c3a\u5bf8\uff08G1-1\/4\"\uff09\u3002<\/li>\n<li>\u8fdb\u3001\u51fa\u6c34\u7ba1\u8bf7\u59a5\u5584\u4fdd\u6e29\u7edd\u70ed\uff0c\u9632\u6b62\u51b7\u51dd\u6c34\u6216\u7ba1\u8def\u51bb\u7ed3\u3002<\/li>\n<li>\u8fc7\u6ee4\u5668\uff08\u6216\u7403\u9600\u8fc7\u6ee4\u5668\uff09\u5e94\u5b89\u88c5\u5230\u6c34\u6a21\u5757\u8fdb\u6c34\u53e3\uff0c\u6392\u6c61\u53e3\u5411\u4e0b\u4e14\u6309\u7167\u6c34\u6d41\u65b9\u5411\u5b89\u88c5\u3002\u6839\u636e\u963b\u585e\u7a0b\u5ea6\u5e94\u5b9a\u671f\u6e05\u6d01\u6c34\u8fc7\u6ee4\u5668\u3002<\/li>\n<li>\u5728\u51ac\u5b63\u957f\u65f6\u95f4\u505c\u673a\u65f6\uff0c\u5efa\u8bae\u5c06\u6c34\u6a21\u5757\u548c\u6c34\u7ba1\u8def\u5185\u7684\u6c34\u5168\u90e8\u6392\u51fa\uff0c\u9632\u6b62\u7ed3\u51b0\u3002<\/li>\n<li>\u4efb\u4f55\u957f\u65f6\u95f4\u505c\u673a\u540e\u7684\u521d\u6b21\u542f\u52a8\uff0c\u8bf7\u5f7b\u5e95\u68c0\u67e5\u548c\u6e05\u7406\u673a\u7ec4\u4ee5\u53ca\u6c34\u7ba1\u7cfb\u7edf\u7684\u5176\u4ed6\u8bbe\u5907\u3002<\/li>\n<\/ul>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u968f\u673a\u9644\u4ef6-\u7403\u9600\u8fc7\u6ee4\u5668\u56fe\u793a.jpg\" alt=\"\u7403\u9600\u8fc7\u6ee4\u5668\u5b89\u88c5\u793a\u610f\"><figcaption>\u56fe6.3 \u7403\u9600\u8fc7\u6ee4\u5668\u5b89\u88c5\u793a\u610f\u56fe<\/figcaption><\/figure>\n<h4>\u6c34\u7ba1\u64cd\u4f5c\u57fa\u672c\u8981\u6c42<\/h4>\n<ul>\n<li>\u5b89\u88c5\u524d\u5f7b\u5e95\u51b2\u6d17\u6240\u6709\u6c34\u7ba1\u9053\uff0c\u4f7f\u4e4b\u65e0\u5f02\u7269\u3002<\/li>\n<li>\u914d\u7ba1\u548c\u7ba1\u63a5\u5934\u5fc5\u987b\u6709\u72ec\u7acb\u7684\u652f\u6491\uff0c\u4e0d\u5e94\u652f\u6491\u5728\u6c34\u6a21\u5757\u4e0a\u3002<\/li>\n<li>\u6c34\u6a21\u5757\u7684\u63a5\u7ba1\u548c\u7ba1\u63a5\u5934\u5e94\u5bb9\u6613\u62c6\u9664\uff0c\u4ee5\u4fbf\u4e8e\u64cd\u4f5c\u548c\u6e05\u6d01\u3002<\/li>\n<li>\u5fc5\u987b\u5728\u6c34\u5faa\u73af\u7cfb\u7edf\u8fdb\u51fa\u6c34\u7ba1\u8def\u4e0a\u5b89\u88c5\u95f8\u9600\u3002<\/li>\n<li>\u6c34\u6a21\u5757\u63a5\u53e3\u4e0e\u73b0\u573a\u7ba1\u9053\u4e4b\u95f4\u5e94\u91c7\u7528\u67d4\u6027\u63a5\u5934\u3002<\/li>\n<li>\u91c7\u7528\u9644\u4ef6\u4e2d\u6c34\u7ba1\u63a5\u5934\u5c06\u63a5\u6c34\u76d8\u6392\u6c34\u53e3\u4e0e\u5382\u5916\u7528\u6392\u6c34\u7ba1\u8fde\u63a5\u5728\u4e00\u8d77\uff0c\u7528\u5361\u7b8d\u56fa\u5b9a\u3002<\/li>\n<li>\u7cfb\u7edf\u5185\u6240\u6709\u53ef\u80fd\u51bb\u7ed3\u7684\u6c34\u7ba1\u5747\u5e94\u52a0\u4ee5\u4fdd\u6e29\uff0c\u4ee5\u9632\u6b62\u5728\u4f4e\u6e29\u73af\u5883\u4e0b\u7ba1\u9053\u7ed3\u51b0\u51bb\u88c2\u3002<\/li>\n<li>\u6c34\u7cfb\u7edf\u4e2d\u6240\u6709\u7684\u7ba1\u8def\u90fd\u5fc5\u987b\u4fdd\u6e29\u3002\u4e14\u5982\u679c\u5ba4\u5185\u6e29\u5ea6\u9ad8\u4e8e 30\u2103\uff0c\u76f8\u5bf9\u6e7f\u5ea6\u9ad8\u4e8e 80%\uff0c\u90a3\u4e48\u5bc6\u5c01\u6750\u6599\u7684\u539a\u5ea6\u81f3\u5c11 20mm\uff0c\u907f\u514d\u5bc6\u5c01\u8868\u9762\u51dd\u9732\u3002<\/li>\n<li>\u4e3a\u65b9\u4fbf\u68c0\u4fee\uff0c\u5e94\u5728\u8fdb\u3001\u51fa\u6c34\u7ba1\u8def\u4e0a\u5b89\u88c5\u6e29\u5ea6\u8ba1\u548c\u538b\u529b\u8868\uff08\u9700\u7528\u6237\u81ea\u884c\u91c7\u8d2d\uff09\u3002<\/li>\n<li>\u6c34\u7cfb\u7edf\u7684\u6240\u6709\u4f4e\u70b9\u4f4d\u7f6e\u5747\u5e94\u8bbe\u7f6e\u6392\u6c34\u63a5\u53e3\uff1b\u6240\u6709\u9ad8\u70b9\u4f4d\u7f6e\u5747\u5e94\u8bbe\u7f6e\u6392\u6c14\u88c5\u7f6e\u3002<\/li>\n<\/ul>\n<h4>\u6c34\u5904\u7406\u548c\u6c34\u8d28\u7ba1\u7406<\/h4>\n<p>\u6c34\u5904\u7406\u4e2d\u4f7f\u7528\u4efb\u4f55\u6c34\u57a2\u6291\u5236\u5242\u3001\u9632\u8150\u5242\u524d\uff0c\u8bf7\u4e0e\u6c34\u5904\u7406\u516c\u53f8\u786e\u8ba4\u8fd9\u4e9b\u6eb6\u6db2\u5bf9\u4e0d\u9508\u94a2\u3001\u94dc\u5236\u54c1\u65e0\u8150\u8680\u4f5c\u7528\u3002\u6c34\u8d28\u7ba1\u7406\u529e\u6cd5\u548c\u57fa\u51c6\u53c2\u8003\u65e5\u672c\u51b7\u51bb\u7a7a\u8c03\u5de5\u4e1a\u534f\u4f1a\u7684\u6c34\u8d28\u8981\u6c42\uff08JRA-GL-02-1994\uff09\u3002\u6c34\u6a21\u5757\u673a\u7ec4\u9002\u7528\u4e2d\u4f4e\u6e29\u6c34\u57fa\u51c6\u503c\u89c1\u88686.1\u3002<\/p>\n<table>\n<caption>\u88686.1 \u4e2d\u4f4e\u6e29\u6c34\u3001\u8865\u7ed9\u6c34\u8d28\u57fa\u51c6\uff08\u53c2\u8003\u503c\uff09<\/caption>\n<thead>\n<tr>\n<th rowspan=\"2\">\u9879\u76ee<\/th>\n<th colspan=\"2\">\u4e2d\u4f4e\u6e29\u6c34\u7cfb 20\u2103&lt;T&lt;60\u2103<\/th>\n<th rowspan=\"2\">\u503e\u5411<br \/>\u8150\u8680<\/th>\n<th rowspan=\"2\">\u503e\u5411<br \/>\u6c34\u57a2<\/th>\n<\/tr>\n<tr>\n<th>\u5faa\u73af\u6c34<\/th>\n<th>\u8865\u7ed9\u6c34<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>pH (25\u2103)<\/td>\n<td>7.0~8.0<\/td>\n<td>7.0~8.0<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>\u5bfc\u7535\u6027 (mS\/m) (25\u2103)<\/td>\n<td>&lt;30<\/td>\n<td>&lt;30<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>\u6c2f\u79bb\u5b50 (mgCl\u207b\/L)<\/td>\n<td>&lt;50<\/td>\n<td>&lt;50<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u786b\u9178\u79bb\u5b50 (mgSO\u2084\u00b2\u207b\/L)<\/td>\n<td>&lt;50<\/td>\n<td>&lt;50<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u9178\u6d88\u8017\u91cf pH4.8 (mgCaCO\u2083\/L)<\/td>\n<td>&lt;50<\/td>\n<td>&lt;50<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u603b\u786c\u5ea6 (mgCaCO\u2083\/L)<\/td>\n<td>&lt;70<\/td>\n<td>&lt;70<\/td>\n<td><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>\u9499\u786c\u5ea6 (mgCaCO\u2083\/L)<\/td>\n<td>&lt;50<\/td>\n<td>&lt;50<\/td>\n<td><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>\u79bb\u5b50\u6001\u7845 (mgCaSiO\u2083\/L)<\/td>\n<td>&lt;30<\/td>\n<td>&lt;30<\/td>\n<td><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>\u94c1 (mgFe\/L)<\/td>\n<td>&lt;1.0<\/td>\n<td>&lt;0.3<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>\u94dc (mgCu\/L)<\/td>\n<td>&lt;1.0<\/td>\n<td>&lt;0.1<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u786b\u79bb\u5b50 (mgS\u00b2\u207b\/L)<\/td>\n<td>\u4e0d\u80fd\u6d4b\u5b9a<\/td>\n<td>\u4e0d\u80fd\u6d4b\u5b9a<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u94f5\u79bb\u5b50 (mgNH\u2084\u207a\/L)<\/td>\n<td>&lt;0.3<\/td>\n<td>&lt;0.1<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6b8b\u7559\u6c2f (mgCl\/L)<\/td>\n<td>&lt;0.25<\/td>\n<td>&lt;0.3<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6e38\u79bb\u4e8c\u6c27\u5316\u78b3 (mgCO\u2082\/L)<\/td>\n<td>&lt;0.4<\/td>\n<td>&lt;4.0<\/td>\n<td>\u221a<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7a33\u5b9a\u6307\u6570<\/td>\n<td>-<\/td>\n<td><\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr class=\"section-sep\">\n<p><!-- ====== 7. \u6c34\u5faa\u73af ====== --><\/p>\n<h2 id=\"water-cycle\">7. \u6c34\u5faa\u73af<\/h2>\n<h3>7.1 \u68c0\u67e5\u6c34\u5faa\u73af<\/h3>\n<ul>\n<li>\u6c34\u6a21\u5757\u7531\u8fdb\u6c34\u53e3\u548c\u51fa\u6c34\u53e3\u8fde\u63a5\u5230\u4e00\u4e2a\u6c34\u5faa\u73af\u7cfb\u7edf\uff0c\u5fc5\u987b\u7531\u6709\u8d44\u683c\u7684\u7ba1\u9053\u5de5\u5b89\u88c5\u3002<\/li>\n<li>\u6c34\u6a21\u5757\u53ea\u9002\u7528\u4e8e\u5c01\u95ed\u7684\u6c34\u7cfb\u7edf\uff0c\u5e94\u7528\u5230\u5f00\u653e\u7cfb\u7edf\u53ef\u80fd\u5bfc\u81f4\u6c34\u7ba1\u8150\u8680\u3002<\/li>\n<li>\u7cfb\u7edf\u6700\u5927\u6c34\u538b\u4e0d\u4f1a\u8d85\u8fc7 3bar\uff0c\u82e5\u73b0\u573a\u8865\u6c34\u538b\u529b\u5927\u4e8e 3bar\uff0c\u5efa\u8bae\u5b89\u88c5\u51cf\u538b\u9600\u6216\u81ea\u52a8\u8865\u6c34\u9600\u3002<\/li>\n<li>\u6392\u6c34\u5b54\u5e94\u5728\u6c34\u7cfb\u7edf\u6700\u4f4e\u70b9\u5904\u3002<\/li>\n<li>\u6392\u6c14\u88c5\u7f6e\u5e94\u8be5\u5728\u7cfb\u7edf\u6700\u9ad8\u70b9\u5904\u3002\u68c0\u67e5\u6c34\u6a21\u5757\u4e2d\u7684\u81ea\u52a8\u6392\u6c14\u9600\u53ef\u4ee5\u6b63\u5e38\u6392\u6c14\uff0c\u6709\u6c14\u6d41\u6025\u901f\u6392\u51fa\u7684\u58f0\u97f3\u3002<\/li>\n<li>\u786e\u4fdd\u5b89\u5168\u9600\u53ef\u4ee5\u6b63\u5e38\u6392\u6c34\uff0c\u907f\u514d\u6c34\u6d41\u5165\u673a\u5668\u5185\u63a5\u89e6\u5230\u7535\u6c14\u90e8\u4ef6\u3002<\/li>\n<\/ul>\n<h3>7.2 \u68c0\u67e5\u6c34\u5bb9\u79ef\u548c\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b<\/h3>\n<p>\u6c34\u6a21\u5757\u6709\u4e00\u4e2a 10L \u81a8\u80c0\u7f50\uff0c\u521d\u59cb\u538b\u529b\u51fa\u5382\u8bbe\u5b9a\u503c 1bar\uff0c\u6700\u5927\u5de5\u4f5c\u538b\u529b 3bar\u3002\u4e3a\u907f\u514d\u673a\u7ec4\u8fd0\u884c\u65f6\u5730\u6696\u6c34\u6e29\u4e0a\u5347\u8fc7\u5feb\u9020\u6210\u9891\u7e41\u542f\u505c\u673a\uff0c\u5faa\u73af\u6c34\u5e94\u6709\"\u6700\u5c0f\u6c34\u5bb9\u79ef\"\u8981\u6c42\uff1a\u6700\u5c0f\u6c34\u5bb9\u79ef\u63a8\u8350\u503c\u4e3a 2L\/kW\u3002\u4f8b\u5982\u5916\u673a\u4e3a 16kW \u540d\u4e49\u5236\u70ed\u80fd\u529b\uff0c\u5219\u6700\u5c0f\u6c34\u5bb9\u79ef\u4e3a 32L\u3002\u5728\u5927\u591a\u6570\u60c5\u51b5\u4e0b\u8fd9\u4e2a\u6700\u5c0f\u5bb9\u79ef\u7684\u503c\u90fd\u7b26\u5408\u8981\u6c42\uff1b\u5f53\u6c34\u7cfb\u7edf\u5bb9\u79ef\u4e0d\u6ee1\u8db3\u4e0a\u8ff0\u8981\u6c42\u65f6\uff0c\u9700\u8981\u589e\u52a0\u7f13\u51b2\u6c34\u7bb1\u4ee5\u4fdd\u8bc1\u6c34\u6e29\u76f8\u5bf9\u7a33\u5b9a\u3002<\/p>\n<p>\u4f7f\u7528\u6c34\u5bb9\u91cf\u68c0\u67e5\u8868 7.1\uff0c\u51b3\u5b9a\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b\u662f\u5426\u9700\u8981\u8c03\u6574\uff1a<\/p>\n<table>\n<caption>\u88687.1 \u6c34\u5bb9\u91cf\u68c0\u67e5\u8868<\/caption>\n<thead>\n<tr>\n<th>\u5b89\u88c5\u9ad8\u5ea6\u5dee (H)<\/th>\n<th>\u6c34\u5bb9\u91cf \u2264424L<\/th>\n<th>\u6c34\u5bb9\u91cf &gt;424L<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u22647m<\/td>\n<td>\u4e0d\u9700\u8981\u8c03\u6574\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b<\/td>\n<td>\u9700\u8981\u964d\u4f4e\u521d\u59cb\u538b\u529b\uff0c\u6839\u636e Pg=H\/10+0.3 \u8ba1\u7b97\uff0c\u68c0\u67e5\u6c34\u5bb9\u79ef\u662f\u5426\u6bd4\u5141\u8bb8\u7684\u6700\u5927\u6c34\u5bb9\u79ef\u4f4e<\/td>\n<\/tr>\n<tr>\n<td>&gt;7m<\/td>\n<td>\u9700\u8981\u589e\u52a0\u521d\u59cb\u538b\u529b\uff0c\u6839\u636e Pg=H\/10+0.3 \u8ba1\u7b97\uff0c\u68c0\u67e5\u6c34\u5bb9\u79ef\u662f\u5426\u6bd4\u5141\u8bb8\u7684\u6700\u5927\u6c34\u5bb9\u79ef\u4f4e<\/td>\n<td>\u673a\u7ec4\u7684\u81a8\u80c0\u7f50\u5bf9\u4e8e\u5b89\u88c5\u6765\u8bf4\u592a\u5c0f\uff08\u9700\u8981\u73b0\u573a\u4f9b\u5e94\u5408\u9002\u7684\u81a8\u80c0\u7f50\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u8ba1\u7b97\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b<\/h3>\n<p>\u6839\u636e\u6700\u5927\u5b89\u88c5\u9ad8\u5ea6\u5dee (H)\uff0c\u51b3\u5b9a\u521d\u59cb\u538b\u529b (Pg)\uff1a<strong>Pg = H\/10 + 0.3<\/strong>\uff08\u5355\u4f4d\uff1aH\u2014m\uff0cPg\u2014bar\uff09\u3002\u5176\u4e2d 0.3bar \u4e3a\u81a8\u80c0\u7f50\u5382\u5916\u521d\u59cb\u538b\u529b\u8bbe\u5b9a\u6700\u5c0f\u503c\u3002<\/p>\n<figure><figcaption>\u56fe7.1 \u6700\u5927\u6c34\u5bb9\u79ef\u66f2\u7ebf\u56fe<\/figcaption><!-- \u66f2\u7ebf\u56fe\u65e0\u5bf9\u5e94\u4e0a\u4f20\u56fe\u7247\uff0c\u7528\u8868\u683c\u8bf4\u660e --><\/p>\n<div class=\"spec-card\">\n<p>\u521d\u59cb\u538b\u529b 0.3bar \u65f6\u5bf9\u5e94\u6700\u5927\u6c34\u5bb9\u79ef\u7ea6 424L\uff1b\u521d\u59cb\u538b\u529b\u8d8a\u9ad8\uff0c\u5141\u8bb8\u7684\u6700\u5927\u6c34\u5bb9\u79ef\u8d8a\u5c0f\u3002\u5f53\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b\u8bbe\u4e3a\u6700\u5c0f\u503c 0.3bar \u65f6\u7cfb\u7edf\u6240\u9700\u5faa\u73af\u6c34\u91cf\u4ecd\u5927\u4e8e\u6781\u9650\u503c\uff0c\u9700\u66f4\u6362\u5927\u5bb9\u79ef\u81a8\u80c0\u7f50\u3002<\/p>\n<\/p><\/div>\n<\/figure>\n<h3>7.3 \u8c03\u6574\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b<\/h3>\n<p>\u5f53\u8981\u6539\u53d8\u81a8\u80c0\u7f50\u521d\u59cb\u538b\u529b\u9ed8\u8ba4\u503c\u65f6\uff0c\u53ea\u7528\u5e72\u71e5\u7684\u6c2e\u6c14\u8c03\u6574\u3002\u521d\u59cb\u538b\u529b\u53ea\u80fd\u7531\u6709\u4e13\u4e1a\u77e5\u8bc6\u7684\u4eba\u5458\u8c03\u6574\u3002<\/p>\n<h3>7.4 \u6ce8\u6c34<\/h3>\n<ol>\n<li>\u5982\u679c\u7cfb\u7edf\u5b89\u88c5\u4e86\u8865\u6c34\u53e3\uff0c\u76f4\u63a5\u4ece\u8865\u6c34\u53e3\u8865\u6c34\uff1b\u5426\u5219\u53ef\u901a\u8fc7\u7403\u9600\u7684\u8865\u6c34\u53e3\u8865\u6c34\u3002<\/li>\n<li>\u786e\u4fdd\u81ea\u52a8\u6392\u6c14\u9600\u662f\u6253\u5f00\u7684\uff08\u81f3\u5c11\u65cb\u8f6c 2 \u5708\uff09\u3002<\/li>\n<li>\u76f4\u5230\u6c34\u538b\u529b\u8868\u663e\u793a\u538b\u529b\u7ea6 2bar \u65f6\u505c\u6b62\u8865\u6c34\u3002\u673a\u7ec4\u8fd0\u8f6c\u6b63\u5e38\u6c34\u538b\u8303\u56f4\uff1a\u6c34\u538b\u4f4e\u4e8e 1bar \u65f6\uff0c\u8bf7\u8865\u6c34\u81f3 2bar\u3002<\/li>\n<li>\u6253\u5f00\u5b89\u5168\u9600\uff0c\u68c0\u67e5\u7cfb\u7edf\u4e2d\u6c34\u538b\u8fc7\u5927\u65f6\u662f\u5426\u53ef\u4ee5\u6b63\u5e38\u6392\u6c34\u3002<\/li>\n<\/ol>\n<div class=\"alert alert-note\">\n  <span class=\"label\">\u6ce8<\/span>\u6ce8\u6c34\u65f6\u5e76\u4e0d\u80fd\u6392\u5c3d\u7cfb\u7edf\u4e2d\u5168\u90e8\u7a7a\u6c14\uff0c\u5269\u4f59\u7a7a\u6c14\u5c06\u5728\u7cfb\u7edf\u8fd0\u884c\u5f00\u59cb\u7684\u51e0\u5c0f\u65f6\u91cc\u901a\u8fc7\u81ea\u52a8\u6392\u6c14\u9600\u6392\u51fa\uff0c\u56e0\u6b64\u6839\u636e\u6c34\u538b\u8870\u51cf\u60c5\u51b5\uff0c\u53ef\u80fd\u8fd8\u9700\u989d\u5916\u6ce8\u6c34\u3002\u6c34\u538b\u5e94\u59cb\u7ec8\u4fdd\u6301\u5728 1bar \u4ee5\u4e0a\uff0c\u907f\u514d\u7a7a\u6c14\u8fdb\u5165\u6c34\u5faa\u73af\u3002\n<\/div>\n<hr class=\"section-sep\">\n<p><!-- ====== 8. \u914d\u7ebf ====== --><\/p>\n<h2 id=\"wiring\">8. \u914d\u7ebf<\/h2>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span><\/p>\n<ul>\n<li>\u5728\u63a5\u7535\u7ebf\u6216\u5b9a\u671f\u68c0\u67e5\u4e4b\u524d\uff0c\u5173\u6389\u6c34\u6a21\u5757\u4e0e\u5ba4\u5916\u673a\u7684\u4e3b\u7535\u6e90\u5f00\u5173 10 \u5206\u949f\u4ee5\u4e0a\u3002<\/li>\n<li>\u5fc5\u987b\u5bf9\u7535\u7ebf\u3001\u6392\u6c34\u7ba1\u3001\u7535\u5668\u4ef6\u7b49\u90e8\u4ef6\u52a0\u4ee5\u4fdd\u62a4\uff0c\u4ee5\u9632\u8001\u9f20\u53ca\u5176\u4ed6\u5c0f\u52a8\u7269\u7834\u574f\u3002<\/li>\n<li>\u7528\u80f6\u5e26\u7b49\u6750\u6599\u5305\u88f9\u7535\u7ebf\uff0c\u5c01\u4f4f\u7535\u7ebf\u8fde\u63a5\u5904\uff0c\u9632\u6b62\u51b7\u51dd\u6c34\u53ca\u6606\u866b\u8fdb\u5165\u3002<\/li>\n<li>\u907f\u514d\u7535\u7ebf\u548c\u5236\u51b7\u5242\u7ba1\u9053\u3001\u94a3\u91d1\u7684\u8fb9\u7f18\u53ca\u673a\u5668\u5185\u7684\u7535\u5668\u90e8\u4ef6\u76f8\u63a5\u89e6\u3002<\/li>\n<li>\u4f7f\u7528\u4e2d\u7b49\u611f\u5e94\u901f\u5ea6\u4ee5\u4e0a\u7684 ELB\u3002<\/li>\n<li>\u87ba\u9489\u626d\u77e9\u53c2\u8003\uff1aM4: 1.0~1.3 N\u00b7m\uff1bM5: 2.0~2.4 N\u00b7m\uff1bM6: 4.0~5.0 N\u00b7m\uff1b M7: 9.0~11.0 N\u00b7m\uff1bM8: 18.0~23.0 N\u00b7m\u3002<\/li>\n<\/ul>\n<\/div>\n<h3>8.1 \u4e00\u822c\u68c0\u67e5<\/h3>\n<p>\u786e\u4fdd\u5b89\u88c5\u73b0\u573a\u6240\u7528\u7535\u5668\u4ef6\u5df2\u6309\u7167\u6280\u672f\u624b\u518c\u6570\u636e\u9009\u62e9\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u5de5\u6807\u51c6\u3002\u68c0\u67e5\u7535\u6e90\u7535\u538b\u5728\u989d\u5b9a\u7535\u538b \u00b110% \u8303\u56f4\u5185\u3002\u786e\u8ba4\u5df2\u63a5\u5730\u7ebf\u3002<\/p>\n<table>\n<caption>\u88688.1 \u6c34\u6a21\u5757\u7684\u7535\u53c2\u6570\u53ca\u7535\u7ebf\u89c4\u683c<\/caption>\n<thead>\n<tr>\n<th>\u5bb9\u91cf (10\u00b2W)<\/th>\n<th>\u6700\u5927\u7535\u6d41<\/th>\n<th>\u7535\u6e90<\/th>\n<th>\u7535\u6e90\u7ebf\u89c4\u683c<\/th>\n<th>\u901a\u8baf\u7ebf\u89c4\u683c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>160<\/td>\n<td>1.72A<\/td>\n<td rowspan=\"4\">220V~50Hz<\/td>\n<td rowspan=\"4\">2.5mm\u00b2<\/td>\n<td rowspan=\"4\">0.75mm\u00b2 \u5c4f\u853d\u7ebf<br \/>(RVVPS, \u5c4f\u853d\u5c42\u9700\u63a5\u5730)<\/td>\n<\/tr>\n<tr>\n<td>224<\/td>\n<td>1.74A<\/td>\n<\/tr>\n<tr>\n<td>280<\/td>\n<td>1.97A<\/td>\n<\/tr>\n<tr>\n<td>335<\/td>\n<td>1.99A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"alert alert-note\">\n  <span class=\"label\">\u6ce8<\/span><\/p>\n<ul>\n<li>\u73b0\u573a\u914d\u7ebf\u65f6\u8981\u4f9d\u7167\u5f53\u5730\u6cd5\u5f8b\u6cd5\u89c4\u7684\u89c4\u5b9a\uff0c\u4e14\u6240\u6709\u63a5\u7ebf\u4f5c\u4e1a\u5fc5\u987b\u7531\u6709\u8d44\u683c\u7684\u4e13\u4e1a\u4eba\u5458\u8fdb\u884c\u3002<\/li>\n<li>\u4e0a\u8ff0\u7535\u6e90\u7ebf\u5c3a\u5bf8\u53c2\u7167\u76f8\u5173\u6807\u51c6\u3002\u5728\u7535\u6e90\u7ebf\u4f7f\u7528\u5206\u7ebf\u76d2\u8fde\u63a5\u60c5\u51b5\u4e0b\uff0c\u5408\u8ba1\u7535\u6d41\u503c\u5e76\u6309\u76f8\u5173\u6807\u51c6\u9009\u7535\u7ebf\u3002<\/li>\n<li>\u7535\u6e90\u7ebf\u9009\u7528\u4e0d\u5f97\u8f7b\u4e8e GB\/T 5013.1 \u89c4\u5b9a\u7684\u6c2f\u4e01\u6a61\u80f6\u62a4\u5957\u7ebf 57 \u53f7\u7ebf\u8981\u6c42\uff0c\u7535\u6e90\u7ebf\u8981\u4f7f\u7528\u94dc\u5bfc\u7ebf\u3002<\/li>\n<li>\u5f31\u7535\u901a\u8baf\u56de\u8def\u914d\u7ebf\u89c4\u683c\u4e0d\u4f4e\u4e8e RVVPS \u5c4f\u853d\u7ebf\u6216\u540c\u7b49\u54c1\uff0c\u5c4f\u853d\u5c42\u9700\u63a5\u5730\u3002<\/li>\n<li>\u5982\u679c\u7535\u6e90\u7ebf\u635f\u574f\uff0c\u987b\u53ca\u65f6\u8054\u7cfb\u7ecf\u9500\u5546\u6216\u6307\u5b9a\u7ef4\u4fee\u90e8\u95e8\u7684\u4e13\u4e1a\u4eba\u5458\u8fdb\u884c\u7ef4\u4fee\u66f4\u6362\u3002<\/li>\n<li>\u5b89\u88c5\u7535\u6e90\u7ebf\u65f6\uff0c\u63a5\u5730\u7ebf\u987b\u957f\u4e8e\u8f7d\u6d41\u5bfc\u7ebf\u3002<\/li>\n<li>\u6bcf\u4e2a\u7cfb\u7edf\u5355\u72ec\u5b89\u88c5\u4e3b\u5f00\u5173\u548c ELB\uff0c\u5e76\u9009\u62e9\u53cd\u5e94\u65f6\u95f4\u5728 0.1 \u79d2\u4e4b\u5185\u7684\u9ad8\u7075\u654f\u5ea6 ELB\u3002<\/li>\n<li>\u4ece\u7535\u6e90\u7ebf\u4e2d\u5206\u79bb\u5f00\u5ba4\u5916\u673a\u548c\u5ba4\u5185\u673a\u4e4b\u95f4\u7684\u63a7\u5236\u7ebf\uff0c\u4fdd\u6301\u8ddd\u79bb\u5728 5 \u5230 6cm \u4ee5\u4e0a\uff0c\u63a7\u5236\u7ebf\u4e0d\u80fd\u4e0e\u7535\u6e90\u7ebf\u5e76\u884c\u3002<\/li>\n<li>\u7535\u52a0\u70ed\u4e3a\u9009\u914d\u4ef6\uff0c\u914d\u7f6e\u5916\u7f6e\u7535\u52a0\u70ed\u65f6\u7535\u6e90\u7ebf\u89c4\u683c\u5fc5\u987b\u6309\u5b9e\u9645\u8d1f\u8f7d\u7535\u6d41\u91cd\u65b0\u9009\u914d\u3002<\/li>\n<li>\u5728\u7535\u6e90\u548c\u7a7a\u8c03\u673a\u7ec4\u4e4b\u95f4\uff0c\u5e94\u5b89\u88c5\u80fd\u591f\u786e\u4fdd\u5168\u6781\u65ad\u5f00\u7684\u5f00\u5173\uff0c\u6b64\u5f00\u5173\u89e6\u70b9\u76f8\u8ddd 3mm \u6216\u66f4\u5927\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u4e25\u7981\u4f7f\u7528\u7a7a\u8c03\u7535\u6e90\u7aef\u5b50\u6392\u8f6c\u63a5\u7535\u6e90\u7ebf\uff0c\u53ef\u5728\u7a7a\u8c03\u5185\u673a\u4fa7\u4f7f\u7528\u7535\u6e90\u5206\u7ebf\u76d2\u6269\u5c55\u7535\u6e90\u914d\u7ebf\uff0c\u6ce8\u610f\u914d\u7ebf\u5bb9\u91cf\u8ba1\u7b97\uff0c\u5426\u5219\u914d\u7ebf\u5bb9\u91cf\u8fc7\u5c0f\u5bb9\u6613\u5f15\u8d77\u706b\u707e\u3002\n<\/div>\n<h3>8.2 \u63a5\u7ebf<\/h3>\n<h4>8.2.1 \u6c34\u6a21\u5757\u7ed3\u6784\u56fe<\/h4>\n<p>\u6c34\u6a21\u5757\u7684\u7535\u7ebf\u63a5\u5b54\u4e0e\u5185\u90e8\u8d70\u7ebf\u5982\u4e0b\u56fe\u6240\u793a\u3002\u5ba4\u5185\u3001\u5916\u673a\u914d\u7ebf\u5fc5\u987b\u91c7\u7528\u56fa\u5b9a\u5e03\u7ebf\u8fde\u63a5\u65b9\u5f0f\uff0c\u7a7f\u7ebf\u7ba1\u5fc5\u987b\u91c7\u7528\u786c\u8d28\u5bfc\u7ebf\u7ba1\uff0c\u7a0d\u5fae\u7a7f\u5165\u673a\u5668\u5185\u5373\u53ef\u3002\u7528\u56fa\u7ebf\u5939\u5c06\u7535\u6e90\u7ebf\u4e0e\u901a\u8baf\u7ebf\u5206\u522b\u7d27\u56fa\u3002<\/p>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u7535\u6c14\u63a5\u7ebf\u4e0e\u5185\u90e8\u8d70\u7ebf\u793a\u610f\u56fe.jpg\" alt=\"\u7535\u6c14\u63a5\u7ebf\u4e0e\u5185\u90e8\u8d70\u7ebf\u793a\u610f\u56fe\"><figcaption>\u56fe8.1 &amp; \u56fe8.2 \u7535\u7ebf\u8d70\u7ebf\u4f4d\u7f6e\u793a\u610f\u56fe \/ \u5185\u90e8\u8d70\u7ebf\u793a\u610f\u56fe<\/figcaption><\/figure>\n<h4>8.2.2 \u901a\u8baf\u7ebf\u63a5\u7ebf<\/h4>\n<p>\u7528\u56fa\u7ebf\u5939\u56fa\u5b9a\u597d\u5ba4\u5916\u673a\u4e0e\u6c34\u6a21\u5757\u4e4b\u95f4\u7684\u901a\u8baf\u7ebf\u3002\u4e0e\u5916\u673a\u901a\u8baf\u7ebf\u53ca\u4e0e\u7ebf\u63a7\u5668\u901a\u8baf\u7ebf\u5206\u522b\u8fde\u63a5\uff0c\u786e\u4fdd\u63a5\u7ebf\u7262\u56fa\u3002<\/p>\n<h4>8.2.3 \u7535\u6e90\u7ebf\u63a5\u7ebf<\/h4>\n<ol>\n<li>\u8fde\u63a5\u7535\u6e90\u7ebf\u548c\u5730\u7ebf\u5230\u7535\u6c14\u76d2\u7684\u7aef\u5b50\u4e0a\uff0c\u5e76\u7528\u56fa\u7ebf\u5939\u56fa\u5b9a\u3002<\/li>\n<li>\u68c0\u67e5\u786e\u4fdd\u7535\u6e90\u7aef\u5b50\u6392\u706b\u96f6\u7ebf\u6b63\u786e\u8fde\u63a5\uff0c\u5982\u679c\u63a5\u53cd\uff0c\u4e00\u4e9b\u90e8\u4ef6\u5c06\u88ab\u635f\u574f\u3002<\/li>\n<\/ol>\n<h4>8.2.4 \u8054\u52a8\u529f\u80fd\u63a7\u5236\u63a5\u7ebf<\/h4>\n<p>\u9009\u7528\u5177\u6709\u5e72\u63a5\u70b9\u63a7\u5236\u63a5\u53e3\uff08C1\u3001C2\uff09\u7684\u6e29\u63a7\u5668\u3002\u5404\u4e2a\u6e29\u63a7\u5668\u7684\u5e72\u63a5\u70b9\u5e76\u8054\u540e\u63a5\u5230\u6c34\u6a21\u5757\u7535\u6c14\u76d2\u7ec4\u4ef6\u5185\u7aef\u5b50\u6392\u7684 33\u300134 \u7aef\u5b50\u4e0a\u300233\u300134 \u7aef\u5b50\u95f4\u4e3a\u5f3a\u7535\u7535\u538b 220V\uff0c\u63a5\u7ebf\u81f3\u5c11\u7528 1.0mm\u00b2 \u7684\u7ebf\u3002<\/p>\n<hr class=\"section-sep\">\n<p><!-- ====== 9. \u5916\u7f6e\u6c34\u6cf5 ====== --><\/p>\n<h2 id=\"ext-pump\">9. \u5916\u7f6e\u6c34\u6cf5\u7684\u5b89\u88c5<\/h2>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u672c\u54c1\u5df2\u5185\u7f6e\u6c34\u6cf5\uff0c\u6ee1\u8db3\u4e00\u822c\u6761\u4ef6\u4e0b\u7684\u4f7f\u7528\u9700\u6c42\u3002\u4f46\u5f53\u672b\u7aef\u8fc7\u591a\u3001\u6c34\u4fa7\u7ba1\u8def\u957f\u3001\u963b\u529b\u5927\u3001\u7cfb\u7edf\u6c34\u6d41\u91cf\u8fc7\u5c0f\u65f6\uff0c\u9700\u8981\u5728\u5916\u90e8\u7ba1\u8def\u7cfb\u7edf\u4e2d\u589e\u52a0\u5916\u7f6e\u6c34\u6cf5\u3002\u5916\u7f6e\u6c34\u6cf5\u7684\u542f\u505c\u63a7\u5236\u548c\u5185\u7f6e\u6c34\u6cf5\u5b8c\u5168\u540c\u6b65\u3002\n<\/div>\n<h3>9.1 \u5916\u7f6e\u6c34\u6cf5\u7684\u5b89\u88c5\u4f4d\u7f6e<\/h3>\n<p>\u5916\u7f6e\u6c34\u6cf5\u5b89\u88c5\u5728\u6c34\u6a21\u5757\u51fa\u6c34\u7ba1\u4e0a\u4e3b\u7ba1\u9053\u4e0a\u3002\u51fa\u4e8e\u566a\u97f3\u8003\u8651\uff0c\u5916\u7f6e\u6c34\u6cf5\u9700\u5b89\u88c5\u5728\u5bf9\u566a\u97f3\u8981\u6c42\u4e0d\u9ad8\u7684\u4f4d\u7f6e\u3002<\/p>\n<h3>9.2 \u5916\u7f6e\u6c34\u6cf5\u7684\u9009\u578b\u8981\u6c42<\/h3>\n<ul>\n<li>\u4e32\u8054\u5916\u7f6e\u6c34\u6cf5\u540e\uff0c\u7cfb\u7edf\u6c34\u6d41\u91cf\u4e0d\u80fd\u5927\u4e8e\u6c34\u6a21\u5757\u5185\u7f6e\u6c34\u6cf5\u6700\u5927\u6d41\u91cf\u3002<\/li>\n<li>\u5185\u7f6e\u6c34\u6cf5\u6700\u5927\u627f\u53d7\u538b\u529b 10bar\uff0c\u4e32\u8054\u5916\u7f6e\u6c34\u6cf5\u540e\u4e0d\u80fd\u8d85\u8fc7\u6b64\u503c\u3002<\/li>\n<li>\u9009\u7528\u5916\u7f6e\u6c34\u6cf5\u65f6\uff0c\u9700\u6839\u636e\u5b9e\u9645\u5b89\u88c5\u73af\u5883\u6309\u7167\u6c34\u6cf5\u4ea7\u54c1\u6027\u80fd\u53c2\u6570\u66f2\u7ebf\u9009\u62e9\u5408\u9002\u578b\u53f7\u3002<\/li>\n<li>\u7535\u6c14\u63a5\u7ebf\u9700\u4e25\u683c\u6309\u7167\u8981\u6c42\uff0c\u5426\u5219\u53ef\u80fd\u5bfc\u81f4\u70e7\u6bc1\u4e3b\u63a7\u57fa\u677f\u3002<\/li>\n<\/ul>\n<h3>9.3 \u5916\u7f6e\u6c34\u6cf5\u63a5\u7ebf<\/h3>\n<ul>\n<li><strong>\u8f93\u5165\u529f\u7387 \u2264800W\uff1a<\/strong>\u6c34\u6cf5\u53ef\u76f4\u63a5\u9a71\u52a8\uff0c\u901a\u8fc7\u4e3b\u63a7\u57fa\u677f PCN13 \u7aef\u5b50\u548c\u7aef\u5b50\u6392 31\u300132\u300133 \u63a5\u7ebf\u3002<\/li>\n<li><strong>\u8f93\u5165\u529f\u7387 &gt;800W\uff1a<\/strong>\u9700\u901a\u8fc7\u4ea4\u6d41\u63a5\u89e6\u5668\u9a71\u52a8\uff0c\u6b64\u65f6\u7aef\u5b50\u6392\u8f93\u51fa\u4fe1\u53f7\u53ea\u80fd\u505a\u5916\u7f6e\u6c34\u6cf5\u7684\u63a7\u5236\u4fe1\u53f7\u4f7f\u7528\u3002\u9700\u914d\u7f6e\u4ea4\u6d41\u63a5\u89e6\u5668\u3001\u5269\u4f59\u7535\u6d41\u52a8\u4f5c\u65ad\u8def\u5668\uff08\u6f0f\u4fdd\u5f00\u5173\uff09\u53ca\u5916\u7f6e\u4f9b\u7535\u7535\u6e90\u3002<\/li>\n<\/ul>\n<hr class=\"section-sep\">\n<p><!-- ====== 10. \u5916\u7f6e\u7535\u8f85\u70ed ====== --><\/p>\n<h2 id=\"ext-heat\">10. \u5916\u7f6e\u7535\u8f85\u70ed<\/h2>\n<p>\u5f53\u4f7f\u7528\u673a\u7ec4\u9009\u914d\u7535\u52a0\u70ed\u65f6\uff0c\u8bf7\u5c06 DSW4-1\uff08\u5177\u4f53\u53c2\u9605 DSW4 \u673a\u7ec4\u7279\u6b8a\u529f\u80fd\u8bbe\u5b9a\uff09\u62e8\u6210 ON\u3002<\/p>\n<div class=\"spec-card\">\n  <strong>DSW4 \u673a\u7ec4\u7279\u6b8a\u529f\u80fd\u8bbe\u5b9a\uff1a<\/strong><br \/>\n  \u51fa\u5382\u8bbe\u5b9a\uff08\u5168\u90e8 OFF\uff09\u72b6\u6001 \u2192 \u5c06 DSW4-1 \u62e8\u6210 ON \u5373\u4e3a\"\u673a\u7ec4\u9009\u914d\u7535\u52a0\u70ed\"\u6709\u6548\u3002\n<\/div>\n<h3>10.1 \u5916\u7f6e\u7535\u8f85\u70ed\u9009\u578b\u8981\u6c42<\/h3>\n<ul>\n<li>\u6ee1\u8db3\u56fd\u5bb6\u76f8\u5173\u6cd5\u5f8b\u6cd5\u89c4\u5b89\u5168\u8bbe\u8ba1\u8981\u6c42\u3002<\/li>\n<li>\u5177\u6709\u6e29\u63a7\u4fdd\u62a4\u5f00\u5173\u3002<\/li>\n<li>\u5fc5\u987b\u5339\u914d\u5bf9\u5e94\u89c4\u683c\u4ea4\u6d41\u63a5\u89e6\u5668\u548c\u65ad\u8def\u5668\u4f7f\u7528\u3002<\/li>\n<\/ul>\n<h3>10.2 \u5916\u7f6e\u7535\u8f85\u70ed\u63a5\u7ebf<\/h3>\n<p>\u5916\u7f6e\u7535\u52a0\u70ed\u5fc5\u987b\u901a\u8fc7\u5916\u7f6e\u4ea4\u6d41\u63a5\u89e6\u5668\u7b49\u4e2d\u7ee7\u5668\u7ed9\u7535\u52a0\u70ed\u4f9b\u7535\uff0c\u673a\u7ec4\u53ea\u63d0\u4f9b\u63a7\u5236\u4fe1\u53f7\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th>\u4ee3\u53f7<\/th>\n<th>\u540d\u79f0\/\u4f5c\u7528<\/th>\n<th>\u63a8\u8350\u9009\u578b\u89c4\u683c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>EH<\/td>\n<td>\u7535\u52a0\u70ed\u603b\u6210<\/td>\n<td>\u5fc5\u987b\u6709\u5bf9\u5e94\u7684\u6e29\u5ea6\u4fdd\u62a4\u5f00\u5173\u6216\u6e29\u5ea6\u4fdd\u9669\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>EHT<\/td>\n<td>\u7535\u52a0\u70ed\u7ba1<\/td>\n<td>\u4f9d\u636e\u5b9e\u9645\u9700\u6c42\u9009\u62e9\u529f\u7387<\/td>\n<\/tr>\n<tr>\n<td>TFe<\/td>\n<td>\u6e29\u5ea6\u4fdd\u9669\u7ba1\/\u6e29\u5ea6\u4fdd\u62a4\u5f00\u5173<\/td>\n<td>\u6e29\u5ea6\u4fdd\u62a4\u52a8\u4f5c\u503c\uff1a90\u00b15\u2103<\/td>\n<\/tr>\n<tr>\n<td>THe<\/td>\n<td>\u81ea\u52a8\u6062\u590d\u6e29\u5ea6\u4fdd\u62a4\u5f00\u5173<\/td>\n<td>\u6e29\u5ea6\u4fdd\u62a4\u52a8\u4f5c\u503c\uff1a75\u00b15\u2103<\/td>\n<\/tr>\n<tr>\n<td>AR3<\/td>\n<td>\u4ea4\u6d41\u63a5\u89e6\u5668\uff08\u4e2d\u7ee7\u5668\uff09<\/td>\n<td>\u7535\u52a0\u70ed\u529f\u7387 &gt;3000W \u65f6\u5fc5\u9700<\/td>\n<\/tr>\n<tr>\n<td>FU5 \/ FU6<\/td>\n<td>\u4fdd\u9669\u7ba1<\/td>\n<td>\u6309\u9700\u9009\u578b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u56e0\u7535\u52a0\u70ed\u8d28\u91cf\u3001\u9009\u578b\u4e0d\u5408\u7406\u3001\u672a\u6309\u8981\u6c42\u8fde\u63a5\u7b49\u5bfc\u81f4\u7684\u4e8b\u6545\u6216\u635f\u5931\uff0c\u7a7a\u8c03\u5382\u5bb6\u4e0d\u627f\u62c5\u4efb\u4f55\u8d23\u4efb\u3002\n<\/div>\n<hr class=\"section-sep\">\n<p><!-- ====== 11. \u8bd5\u8fd0\u884c ====== --><\/p>\n<h2 id=\"test-run\">11. \u8bd5\u8fd0\u884c<\/h2>\n<h3>11.1 \u5236\u70ed\u8bd5\u8fd0\u884c<\/h3>\n<p>\u6309\u7167\u6709\u7ebf\u9065\u63a7\u5668\u6216\u8005\u5ba4\u5916\u673a\u76f8\u5173\u64cd\u4f5c\u8c03\u8bd5\u8fd0\u884c\u3002\u5b89\u88c5\u597d\u673a\u7ec4\u540e\uff0c\u5728\u6253\u5f00\u6f0f\u7535\u65ad\u8def\u5668\u524d\u8bf7\u6392\u67e5\u4ee5\u4e0b\u4e8b\u9879\uff1a<\/p>\n<ol>\n<li><strong>\u73b0\u573a\u914d\u7ebf<\/strong> \u2014 \u786e\u4fdd\u914d\u7ebf\u6309\u7167\u914d\u7ebf\u56fe\u548c\u56fd\u5bb6\u6cd5\u89c4\u8fdb\u884c\u3002<\/li>\n<li><strong>\u4fdd\u9669\u4e1d\u6216\u4fdd\u62a4\u88c5\u7f6e<\/strong> \u2014 \u68c0\u67e5\u5c3a\u5bf8\u548c\u578b\u53f7\u662f\u5426\u7b26\u5408\u8868 8.1 \u7684\u6280\u672f\u89c4\u683c\u3002<\/li>\n<li><strong>\u5730\u7ebf<\/strong> \u2014 \u786e\u4fdd\u5730\u7ebf\u5df2\u8fde\u63a5\u4e14\u63a5\u5730\u7b26\u5408\u8981\u6c42\u3002<\/li>\n<li><strong>\u5185\u90e8\u914d\u7ebf<\/strong> \u2014 \u68c0\u67e5\u7535\u6c14\u76d2\u5185\u6709\u65e0\u677e\u52a8\u7684\u63d2\u63a5\u5668\u6216\u635f\u574f\u7684\u7535\u6c14\u5143\u4ef6\u3002<\/li>\n<li><strong>\u56fa\u5b9a<\/strong> \u2014 \u68c0\u67e5\u673a\u7ec4\u662f\u5426\u56fa\u5b9a\uff0c\u907f\u514d\u542f\u52a8\u65f6\u6709\u4e0d\u6b63\u5e38\u566a\u97f3\u548c\u632f\u52a8\u3002<\/li>\n<li><strong>\u635f\u574f\u7684\u90e8\u4ef6<\/strong> \u2014 \u68c0\u67e5\u673a\u7ec4\u5185\u90e8\u6709\u65e0\u635f\u574f\u7684\u5143\u4ef6\u6216\u6324\u538b\u8fc7\u7684\u7ba1\u5b50\u3002<\/li>\n<li><strong>\u5236\u51b7\u5242\u6cc4\u6f0f<\/strong> \u2014 \u68c0\u67e5\u6709\u65e0\u5236\u51b7\u5242\u6cc4\u6f0f\uff0c\u5982\u6709\u8bf7\u8054\u7cfb\u5f53\u5730\u7ecf\u9500\u5546\u3002<\/li>\n<li><strong>\u7535\u6e90\u7535\u538b<\/strong> \u2014 \u7535\u538b\u5fc5\u987b\u7b26\u5408\u673a\u7ec4\u94ed\u724c\u4e0a\u7684\u7535\u538b\u503c\u3002<\/li>\n<li><strong>\u6392\u6c14\u9600<\/strong> \u2014 \u786e\u4fdd\u81ea\u52a8\u6392\u6c14\u9600\u662f\u6253\u5f00\u7684\uff0c\u81f3\u5c11\u62e7\u5f00\u4e24\u5708\u3002<\/li>\n<li><strong>\u5b89\u5168\u9600<\/strong> \u2014 \u68c0\u67e5\u7cfb\u7edf\u5df2\u5b8c\u5168\u6ce8\u6ee1\u6c34\uff0c\u5b89\u5168\u9600\u624b\u52a8\u6253\u5f00\u65f6\u6392\u51fa\u7684\u662f\u6c34\u800c\u975e\u7a7a\u6c14\u3002<\/li>\n<li><strong>\u7403\u9600<\/strong> \u2014 \u786e\u4fdd\u7403\u9600\u6b63\u786e\u5b89\u88c5\u5e76\u5b8c\u5168\u6253\u5f00\u3002\u5173\u95ed\u9600\u95e8\u8fd0\u884c\u4f1a\u635f\u574f\u6c34\u6cf5\u3002<\/li>\n<li><strong>\u7535\u52a8\u4e09\u901a\u9600<\/strong> \u2014 \u786e\u4fdd\u63a5\u7ebf\u65b9\u5f0f\u548c\u9600\u4f53\u5b89\u88c5\u65b9\u5411\u90fd\u7b26\u5408\u8981\u6c42\u3002<\/li>\n<\/ol>\n<h4>\u8bd5\u8fd0\u884c\u524d\u6c34\u8def\u68c0\u67e5<\/h4>\n<ol type=\"A\">\n<li>\u786e\u8ba4\u6240\u6709\u6c34\u7ba1\u65bd\u5de5\u5747\u5904\u4e8e\u6b63\u786e\u72b6\u6001\u3002<\/li>\n<li>\u5411\u6c34\u6a21\u5757\u6ce8\u6c34\uff0c\u786e\u8ba4\u677f\u5f0f\u6362\u70ed\u5668\u5185\u6ce8\u6ee1\u5faa\u73af\u6c34\uff1b\u5f00\u542f\u6c34\u6cf5\u548c\u6392\u6c14\u9600\uff0c\u786e\u8ba4\u673a\u7ec4\u53ca\u7ba1\u8def\u5185\u7a7a\u6c14\u5df2\u7ecf\u6392\u51fa\u3002<\/li>\n<li>\u5c06\u57fa\u677f\u4e0a\u62e8\u7801\u5f00\u5173 DSW3-2 \u62e8\u6210 ON \u53ef\u5f3a\u5236\u8fd0\u884c\u6c34\u6cf5\uff0c\u901a\u8fc7\u8bfb\u53d6\u538b\u529b\u8868\u7684\u503c\u53ca\u786e\u8ba4\u6c34\u6d41\u5f00\u5173\u52a8\u4f5c\u6765\u68c0\u67e5\u6c34\u5faa\u73af\u7cfb\u7edf\u5b89\u88c5\u662f\u5426\u6b63\u786e\u3002\u68c0\u67e5\u5b8c\u6bd5\u540e\u8bf7\u5c06\u62e8\u7801\u5f00\u5173\u62e8\u4e0b\u3002<\/li>\n<li>\u9996\u6b21\u8bd5\u8fd0\u884c\u540e\uff0c\u6e05\u7406\u6c34\u8fc7\u6ee4\u5668\uff0c\u786e\u8ba4\u8fc7\u6ee4\u7f51\u6e05\u6d01\u65e0\u6c61\u7269\u3002<\/li>\n<\/ol>\n<div class=\"alert alert-warning\">\n  <span class=\"label\">\u8b66\u544a<\/span>\u6240\u6709\u68c0\u67e5\u70b9\u90fd\u5df2\u67e5\u6e05\u540e\u624d\u53ef\u542f\u52a8\u673a\u5668\u3002\u7cfb\u7edf\u8fd0\u884c\u65f6\u4e0d\u8981\u89e6\u6478\u6392\u6c14\u7aef\u4efb\u4f55\u90e8\u4ef6\uff08\u6e29\u5ea6\u9ad8\u8fbe 90\u2103 \u4ee5\u4e0a\uff09\u3002\u4e0d\u8981\u6309\u4ea4\u6d41\u63a5\u89e6\u5668\u6309\u94ae\u3002\u5173\u65ad\u4e3b\u7535\u6e90\u540e 10 \u5206\u949f\u5185\u4e0d\u8981\u89e6\u6478\u4efb\u4f55\u7535\u5668\u5143\u4ef6\u3002\n<\/div>\n<h3>11.2 \u6253\u5f00\u6c34\u6a21\u5757\u7535\u6e90<\/h3>\n<p>\u6253\u5f00\u6c34\u6a21\u5757\u7684\u7535\u6e90\u540e\uff0c\u521d\u59cb\u72b6\u6001\u65f6\u7ebf\u63a7\u5668\u4e0a\u56fe\u4f1a\u5168\u90e8\u663e\u793a\u6301\u7eed 10 \u79d2\u3002<\/p>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5f53\u5ba4\u5916\u6e29\u5ea6\u8f83\u4f4e\u65f6\uff0c\u6253\u5f00\u6c34\u6a21\u5757\u7535\u6e90\u53ef\u80fd\u4f1a\u76f4\u63a5\u8fdb\u5165\u9632\u51bb\u7ed3\u8fd0\u8f6c\u6a21\u5f0f\uff0c\u6c34\u6cf5\u4f1a\u81ea\u52a8\u8fd0\u884c\uff0c\u8fd9\u5c5e\u4e8e\u6b63\u5e38\u73b0\u8c61\u3002\n<\/div>\n<h3>11.3 \u73b0\u573a\u8bbe\u5b9a<\/h3>\n<p>\u5b89\u88c5\u4eba\u5458\u53ef\u6839\u636e\u5b89\u88c5\u73af\u5883\u4ee5\u53ca\u7528\u6237\u9700\u8981\u901a\u8fc7\u7ebf\u63a7\u5668\u5bf9\u53ef\u9009\u53c2\u6570\u8fdb\u884c\u8bbe\u5b9a\uff0c\u5177\u4f53\u89c1\"\u6709\u7ebf\u9065\u63a7\u5668\"\u8bf4\u660e\u4e66\u3002\u901a\u8fc7\u5ba4\u5916\u673a\u62e8\u7801\u5f00\u5173\u8fdb\u884c\u8bd5\u8fd0\u8f6c\u540e\uff0c\u52a1\u5fc5\u8bb0\u4f4f\u5c06\u62e8\u7801\u5f00\u5173\u62e8\u56de\u5230\u51fa\u5382\u8bbe\u5b9a\u72b6\u6001\u3002<\/p>\n<h3>11.4 \u8bd5\u8fd0\u8f6c\u548c\u6700\u7ec8\u68c0\u67e5<\/h3>\n<p>\u5b89\u88c5\u5b8c\u6210\u540e\u5fc5\u987b\u68c0\u67e5\u6c34\u6a21\u5757\u548c\u5ba4\u5916\u673a\u662f\u5426\u6b63\u786e\u5b89\u88c5\u3002\u8bd5\u8fd0\u8f6c\u53ef\u901a\u8fc7\u6709\u7ebf\u9065\u63a7\u5668\u6216\u8005\u5ba4\u5916\u673a\u64cd\u4f5c\u5b9e\u73b0\uff0c\u8be6\u89c1\u6709\u7ebf\u63a7\u5668\u8bf4\u660e\u4e66\u6216\u8005\u5ba4\u5916\u673a\u76f8\u5173\u64cd\u4f5c\u8bf4\u660e\u3002\u5982\u679c\u6709\u9519\u8bef\u6216\u6545\u969c\uff0c\u6709\u7ebf\u9065\u63a7\u5668\u5c4f\u5e55\u4e0a\u4f1a\u663e\u793a\u6545\u969c\u4ee3\u7801\u3002<\/p>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u8bd5\u8fd0\u8f6c\u65f6\u6c34\u6a21\u5757\u8bbe\u5b9a\u6c34\u6e29\u8f83\u9ad8\uff0855\u2103\uff09\uff0c\u70ed\u80c0\u51b7\u7f29\u4f1a\u5bf9\u5730\u677f\u9020\u6210\u4e00\u5b9a\u635f\u4f24\uff0c\u8bf7\u63a7\u5236\u5730\u6696\u8bd5\u8fd0\u884c\u65f6\u95f4\u5728 30 \u5206\u949f\u5185\u3002\u4f4e\u6e29\u70ed\u6c34\u5730\u9762\u8f90\u5c04\u4f9b\u6696\u7cfb\u7edf\u672a\u7ecf\u8c03\u8bd5\u4e25\u7981\u8fd0\u884c\u4f7f\u7528\uff0c\u521d\u6b21\u4f9b\u6696\u65f6\u70ed\u6c34\u5347\u6e29\u5e94\u5e73\u7f13\u3002\n<\/div>\n<hr class=\"section-sep\">\n<p><!-- ====== \u6545\u969c\u4ee3\u7801 ====== --><\/p>\n<h2 id=\"codes\">\u6545\u969c\u4ee3\u7801\u8868<\/h2>\n<table>\n<caption>\u886811.1 \u62a5\u8b66\u4ee3\u7801<\/caption>\n<thead>\n<tr>\n<th>\u6545\u969c\u4ee3\u7801<\/th>\n<th>\u5f02\u5e38\u60c5\u51b5<\/th>\n<th>\u6545\u969c\u539f\u56e0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>03<\/td>\n<td>\u901a\u8baf\u5f02\u5e38<\/td>\n<td>\u6c34\u6a21\u5757\u548c\u5ba4\u5916\u673a\u901a\u4fe1\u6545\u969c<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>\u5165\u53e3\u6c34\u6e29\u4f20\u611f\u5668\u5f02\u5e38<\/td>\n<td>\u6e29\u5ea6\u4f20\u611f\u5668\u7ebf\u77ed\u8def\u6216\u8005\u5f00\u8def<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>\u51fa\u53e3\u6c34\u6e29\u4f20\u611f\u5668\u5f02\u5e38<\/td>\n<td>\u6e29\u5ea6\u4f20\u611f\u5668\u7ebf\u77ed\u8def\u6216\u8005\u5f00\u8def<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>\u6db2\u7ba1\u6e29\u5ea6\u4f20\u611f\u5668\u5f02\u5e38<\/td>\n<td>\u6e29\u5ea6\u4f20\u611f\u5668\u7ebf\u77ed\u8def\u6216\u8005\u5f00\u8def<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>\u6c14\u7ba1\u6e29\u5ea6\u4f20\u611f\u5668\u5f02\u5e38<\/td>\n<td>\u6e29\u5ea6\u4f20\u611f\u5668\u7ebf\u77ed\u8def\u6216\u8005\u5f00\u8def<\/td>\n<\/tr>\n<tr>\n<td>70<\/td>\n<td>\u6c34\u5f02\u5e38<\/td>\n<td>\u6c34\u7cfb\u7edf\u6c34\u538b\u4e0d\u591f\uff0c\u6216\u8005\u6c34\u6d41\u91cf\u4f4e\u4e0b<\/td>\n<\/tr>\n<tr>\n<td>76<\/td>\n<td>\u6db2\u7ba1\u51bb\u7ed3<\/td>\n<td>\u6db2\u7ba1\u6e29\u5ea6\u4f4e\u4e0b<\/td>\n<\/tr>\n<tr>\n<td>79<\/td>\n<td>\u5ba4\u5916\u5355\u5143\u7ec4\u5408\u5f02\u5e38<\/td>\n<td>\u5ba4\u5916\u5355\u5143\u578b\u53f7\u4e0d\u5339\u914d<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>\u901a\u8baf\u5f02\u5e38<\/td>\n<td>\u6c34\u6a21\u5757\u4e0e\u7ebf\u63a7\u5668\u901a\u4fe1\u6545\u969c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u65e5\u7acb\u6c34\u6a21\u575716\u6545\u969c\u4ee3\u7801\u8bf4\u660e_\u89c4\u8303\u7248.jpg\" alt=\"\u65e5\u7acb\u6c34\u6a21\u5757\u6545\u969c\u4ee3\u7801\u8bf4\u660e\"><figcaption>\u56fe\uff1a\u65e5\u7acb\u6c34\u6a21\u5757\u6545\u969c\u4ee3\u7801\u8bf4\u660e\uff08\u89c4\u8303\u7248\uff09<\/figcaption><\/figure>\n<hr class=\"section-sep\">\n<p><!-- ====== \u8bd5\u8fd0\u8f6c\u53ca\u4fdd\u517b\u8bb0\u5f55 ====== --><\/p>\n<h3>\u886811.2 \u8bd5\u8fd0\u8f6c\u53ca\u4fdd\u517b\u8bb0\u5f55<\/h3>\n<div class=\"spec-card\">\n<p><strong>\u578b\u53f7\uff1a_______ &nbsp;&nbsp; \u5e8f\u53f7\uff1a_______ &nbsp;&nbsp; \u538b\u7f29\u673a\u53f7\uff1a_______ &nbsp;&nbsp; \u7528\u6237\u540d\u79f0\u548c\u5730\u5740\uff1a_______ &nbsp;&nbsp; \u65e5\u671f\uff1a_______<\/strong><\/p>\n<\/div>\n<ol class=\"checklist\">\n<li>\u81ea\u52a8\u6392\u6c14\u9600\u662f\u5426\u6b63\u5e38\u6392\u6c14\uff1f<\/li>\n<li>\u538b\u529b\u8868\u793a\u6570\u662f\u5426\u663e\u793a\u6ce8\u6c34\u538b\u529b\u5df2\u8fbe\u5230\u8981\u6c42\u7684\u538b\u529b\uff081.0-2.5bar\uff09\uff1f<\/li>\n<li>\u6c34\u6a21\u5757\u8fdb\u3001\u51fa\u6c34\u53e3\u5b89\u88c5\u662f\u5426\u6b63\u786e\uff0c\u6240\u6709\u6c34\u7ba1\u662f\u5426\u505a\u4e86\u65e0\u6cc4\u6f0f\u68c0\u67e5\uff1f<\/li>\n<li>\u968f\u673a\u6240\u914d\u9644\u4ef6\u662f\u5426\u6b63\u786e\u5b89\u88c5\uff1f<\/li>\n<li>\u538b\u7f29\u673a\u6709\u65e0\u5f02\u5e38\u7684\u58f0\u97f3\uff1f<\/li>\n<li>\u7cfb\u7edf\u662f\u5426\u5df2\u542f\u52a8\u81f3\u5c11 20 \u5206\u949f\uff1f<\/li>\n<li>\u67e5\u6c34\u6a21\u5757\u8fdb\u3001\u51fa\u6c34\u6e29\u5ea6 \u2014 \u8fdb\u53e3\uff1a___\u2103 &nbsp; \u51fa\u53e3\uff1a___\u2103<\/li>\n<li>\u67e5\u5236\u51b7\u5242\u6e29\u5ea6 \u2014 \u5236\u51b7\u5242\u6db2\u7ba1\u6e29\u5ea6\uff1a___\u2103 &nbsp; \u5236\u51b7\u5242\u6c14\u7ba1\u6e29\u5ea6\uff1a___\u2103<\/li>\n<li>\u67e5\u538b\u529b \u2014 \u6392\u6c14\u538b\u529b\uff1a___MPa &nbsp; \u5438\u6c14\u538b\u529b\uff1a___MPa<\/li>\n<li>\u67e5\u7535\u538b \u2014 \u989d\u5b9a\u7535\u538b\uff1a___V &nbsp; \u8fd0\u8f6c\u7535\u538b\uff1a___V &nbsp; \u542f\u52a8\u7535\u538b\uff1a___V<\/li>\n<li>\u67e5\u538b\u7f29\u673a\u8f93\u5165\u8fd0\u884c\u7535\u6d41 \u2014 \u8f93\u5165\u529f\u7387\uff1a___kW &nbsp; \u8fd0\u8f6c\u7535\u6d41\uff1a___A<\/li>\n<li>\u662f\u5426\u6709\u8db3\u591f\u6c34\u6d41\u901a\u8fc7\u677f\u5f0f\u6362\u70ed\u5668\uff1f<\/li>\n<li>\u5236\u51b7\u5242\u5145\u6ce8\u91cf\u662f\u5426\u8db3\u591f\uff1f<\/li>\n<li>\u8fd0\u884c\u63a7\u5236\u88c5\u7f6e\u662f\u5426\u6b63\u786e\uff1f<\/li>\n<li>\u5b89\u5168\u88c5\u7f6e\uff08\u5982\u6d41\u91cf\u5f00\u5173\uff09\u662f\u5426\u52a8\u4f5c\u6b63\u5e38\uff1f<\/li>\n<li>\u662f\u5426\u5df2\u505a\u4e86\u5236\u51b7\u7cfb\u7edf\u68c0\u6f0f\u548c\u6c34\u7cfb\u7edf\u68c0\u6f0f\uff1f<\/li>\n<li>\u6240\u6709\u673a\u5668\u76d6\u677f\u662f\u5426\u5df2\u56fa\u5b9a\u597d\uff1f<\/li>\n<li>\u6240\u6709\u673a\u5668\u76d6\u677f\u662f\u5426\u6709\u5f02\u5e38\u58f0\u54cd\uff1f<\/li>\n<li>\u6c34\u8fc7\u6ee4\u5668\u6ee4\u7f51\u662f\u5426\u6e05\u6d01\uff1f<\/li>\n<li>\u9996\u6b21\u8bd5\u8fd0\u884c\u540e\uff0c\u6c34\u8fc7\u6ee4\u5668\u662f\u5426\u6e05\u6d17\u5b8c\u6bd5\uff1f<\/li>\n<li>\u622a\u6b62\u9600\u662f\u5426\u6253\u5f00\u5b8c\u5168\uff1f<\/li>\n<li>\u673a\u5668\u5185\u5916\u662f\u5426\u6e05\u7406\u5e72\u51c0\uff1f<\/li>\n<li>\u63a5\u6c34\u76d8\u6392\u6c34\u53e3\u662f\u5426\u80fd\u987a\u7545\u6392\u5165\u4e0b\u6c34\u7ba1\u9053\uff1f<\/li>\n<\/ol>\n<hr class=\"section-sep\">\n<p><!-- ====== 12. \u7ef4\u62a4\u548c\u4fdd\u517b ====== --><\/p>\n<h2 id=\"maintain\">12. \u7ef4\u62a4\u548c\u4fdd\u517b<\/h2>\n<div class=\"alert alert-caution\">\n  <span class=\"label\">\u6ce8\u610f<\/span>\u5f00\u59cb\u7ef4\u4fee\u4fdd\u517b\u524d\uff0c\u8bf7\u52a1\u5fc5\u5173\u95ed\u5ba4\u5916\u673a\u4e0e\u6c34\u6a21\u5757\u7684\u7535\u6e90\u3002\n<\/div>\n<p>\u6c34\u6a21\u5757\u673a\u7ec4\u5e94\u5b9a\u671f\u6309\u7167\"\u8bd5\u8fd0\u884c\"\u4e00\u8282\u4e2d\u6240\u8ff0\u76f8\u540c\u9879\u76ee\u8fdb\u884c\u68c0\u67e5\u3002\u4e0b\u8ff0\u5185\u5bb9\u6bcf\u5e74\u81f3\u5c11\u68c0\u67e5\u4e00\u6b21\uff1a<\/p>\n<ol>\n<li><strong>\u6c34\u538b<\/strong> \u2014 \u68c0\u67e5\u6c34\u538b\u662f\u5426\u4e0d\u4f4e\u4e8e 1bar\uff0c\u5982\u679c\u5fc5\u8981\u8bf7\u52a0\u6c34\u3002<\/li>\n<li><strong>\u8fc7\u6ee4\u5668<\/strong> \u2014 \u6e05\u6d01\u6c34\u8fc7\u6ee4\u5668\u53ca\u8fc7\u6ee4\u7f51\u3002<\/li>\n<li><strong>\u5b89\u5168\u9600<\/strong> \u2014 \u62e8\u52a8\u5b89\u5168\u9600\u624b\u52a8\u5f00\u5173\u68c0\u67e5\u662f\u5426\u6709\u6c34\u6d41\u51fa\uff1b\u5982\u65e0\u6c34\u6d41\u51fa\u8054\u7cfb\u7ecf\u9500\u5546\uff1b\u5982\u6c34\u6301\u7eed\u6d41\u51fa\uff0c\u5148\u5173\u95ed\u6c34\u7ba1\u8def\u4e0a\u9600\u95e8\u518d\u8054\u7cfb\u7ecf\u9500\u5546\u3002<\/li>\n<li><strong>\u5b89\u5168\u9600\u6392\u6c34\u8f6f\u7ba1<\/strong> \u2014 \u68c0\u67e5\u8f6f\u7ba1\u4f4d\u7f6e\u662f\u5426\u9002\u5f53\uff0c\u80fd\u6392\u51fa\u6c34\u3002<\/li>\n<li><strong>\u7535\u6c14\u76d2<\/strong>\uff08\u5fc5\u987b\u8054\u7cfb\u7ecf\u9500\u5546\uff09\u2014 \u68c0\u67e5\u662f\u5426\u6709\u677e\u52a8\u7684\u63a5\u7ebf\u3002<\/li>\n<li><strong>\u98ce\u673a\u76d8\u7ba1<\/strong> \u2014 \u4fdd\u517b\u65b9\u6cd5\u8bf7\u53c2\u9605\u98ce\u673a\u76d8\u7ba1\u7684\u8bf4\u660e\u4e66\u3002<\/li>\n<\/ol>\n<div class=\"alert alert-note\">\n  <span class=\"label\">\u6ce8<\/span>\u4ee5\u4e0b\u68c0\u67e5\u9664\u7279\u6b8a\u8bf4\u660e\u5916\uff0c\u5747\u53ef\u7531\u7528\u6237\u81ea\u884c\u68c0\u67e5\uff0c\u53d1\u73b0\u5f02\u5e38\u53ca\u65f6\u8054\u7cfb\u5f53\u5730\u7ecf\u9500\u5546\u3002\n<\/div>\n<h4>\u7279\u522b\u6ce8\u610f\u4e8b\u9879<\/h4>\n<ol>\n<li><strong>\u677f\u5f0f\u6362\u70ed\u5668\u51bb\u7ed3<\/strong> \u2014 \u5b9a\u671f\u68c0\u67e5\u6c34\u6a21\u5757\u8fdb\u51fa\u6c34\u6e29\u5ea6\u5dee\u3001\u538b\u529b\u5dee\uff0c\u68c0\u67e5\u8fc7\u6ee4\u5668\u662f\u5426\u5835\u585e\u3001\u7cfb\u7edf\u6c34\u91cf\u51cf\u5c11\u6216\u6709\u7a7a\u6c14\u5438\u5165\u3002\u53d1\u751f\u677f\u5f0f\u6362\u70ed\u5668\u5185\u90e8\u51bb\u7ed3\u65f6\u7acb\u5373\u505c\u6b62\u673a\u7ec4\u8fd0\u884c\uff0c\u67e5\u6e05\u6392\u9664\u539f\u56e0\u4e4b\u524d\u7981\u6b62\u518d\u6b21\u542f\u52a8\u3002<\/li>\n<li><strong>\u6c34\u8def\u6c89\u79ef\u5835\u585e<\/strong> \u2014 \u8fd0\u884c\u4e00\u6bb5\u65f6\u95f4\u540e\u5916\u6765\u5fae\u7c92\u3001\u7070\u5c18\u548c\u78b3\u9178\u9499\u7b49\u77ff\u7269\u8d28\u5728\u677f\u5f0f\u6362\u70ed\u5668\u8868\u9762\u6c89\u79ef\uff0c\u5c06\u8fc7\u5ea6\u6d88\u8017\u7535\u529b\u5e76\u53ef\u80fd\u5bfc\u81f4\u677f\u5f0f\u6362\u70ed\u5668\u51bb\u7ed3\u3002\u6839\u636e\u6c34\u8fc7\u6ee4\u5668\u963b\u585e\u7a0b\u5ea6\u5b9a\u671f\u6e05\u6d01\uff0c\u5426\u5219\u53ef\u80fd\u56e0\u5f02\u5e38\u538b\u529b\u5bfc\u81f4\u6ee4\u7f51\u7834\u635f\u3002<\/li>\n<\/ol>\n<hr class=\"section-sep\">\n<p><!-- ====== 13. \u4fdd\u62a4\u548c\u63a7\u5236\u88c5\u7f6e ====== --><\/p>\n<h2>13. \u4fdd\u62a4\u548c\u63a7\u5236\u88c5\u7f6e<\/h2>\n<p><strong>\u6c34\u6cf5\u7684\u4fdd\u62a4\uff1a<\/strong>\u6c34\u6cf5\u5f02\u5e38\u5bfc\u81f4\u7535\u6d41\u5927\u4e8e 10A\uff0c\u7535\u6d41\u4fdd\u9669\u4e1d\u7194\u65ad\uff08\u4e0d\u53ef\u6062\u590d\uff09\uff0c\u505c\u673a\u4fdd\u62a4\uff1b\u5f53\u6c34\u8def\u4e2d\u6c34\u6d41\u6216\u538b\u529b\u5c0f\u4e8e\u8bbe\u5b9a\u503c\uff0c\u6c34\u6cf5\u6d41\u91cf\u62a5\u8b66\u6216\u538b\u529b\u5f00\u5173\u52a8\u4f5c\uff0c\u505c\u673a\u4fdd\u62a4\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th>\u5bb9\u91cf<\/th>\n<th>160\/224<\/th>\n<th>280\/335<\/th>\n<th>\u5907\u6ce8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u63a7\u5236\u7535\u8def\u57fa\u677f\u4fdd\u9669\u4e1d\u5bb9\u91cf<\/td>\n<td>10A<\/td>\n<td>10A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5\u7535\u6e90\u4fdd\u9669\u4e1d\u5bb9\u91cf<\/td>\n<td>10A<\/td>\n<td>10A<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr class=\"section-sep\">\n<p><!-- ====== \u4ea7\u54c1\u4e2d\u6709\u5bb3\u7269\u8d28 ====== --><\/p>\n<h2>\u4ea7\u54c1\u4e2d\u6709\u5bb3\u7269\u8d28\u7684\u540d\u79f0\u53ca\u542b\u91cf<\/h2>\n<p>\u672c\u8868\u683c\u4f9d\u636e SJ\/T 11364 \u7684\u89c4\u5b9a\u7f16\u5236\u3002\u25cb\uff1a\u8868\u793a\u8be5\u6709\u5bb3\u7269\u8d28\u5728\u8be5\u90e8\u4ef6\u6240\u6709\u5747\u8d28\u6750\u6599\u4e2d\u7684\u542b\u91cf\u5728 GB\/T 26572 \u89c4\u5b9a\u7684\u9650\u91cf\u8981\u6c42\u4ee5\u4e0b\uff1b\u00d7\uff1a\u8868\u793a\u81f3\u5c11\u5728\u8be5\u90e8\u4ef6\u7684\u67d0\u4e00\u5747\u8d28\u6750\u6599\u4e2d\u542b\u91cf\u8d85\u51fa\u9650\u91cf\u8981\u6c42\uff0c\u7531\u4e8e\u6280\u672f\u539f\u56e0\u76ee\u524d\u65e0\u6cd5\u5b9e\u73b0\u66ff\u4ee3\uff0c\u540e\u7eed\u968f\u7740\u6280\u672f\u8fdb\u6b65\u5c06\u9010\u6e10\u6539\u8fdb\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th>\u90e8\u4ef6<\/th>\n<th>\u94c5(Pb)<\/th>\n<th>\u6c5e(Hg)<\/th>\n<th>\u9549(Cd)<\/th>\n<th>\u516d\u4ef7\u94ec(CrVI)<\/th>\n<th>\u591a\u6eb4\u8054\u82ef(PBB)<\/th>\n<th>\u591a\u6eb4\u4e8c\u82ef\u919a(PBDE)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u6362\u70ed\u5668<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u8def\u4ef6<\/td>\n<td>\u00d7<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5<\/td>\n<td>\u00d7<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u6c34\u7bb1<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u52a0\u70ed\u5668<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u80c0\u6c34\u7bb1<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u52a8\u4e09\u901a\u7403\u9600<\/td>\n<td>\u00d7<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u538b\u529b\u8868<\/td>\n<td>\u00d7<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u9600\u7c7b<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u87ba\u9489\u3001\u87ba\u6813\u7b49\u7d27\u56fa\u4ef6<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u94a3\u91d1\u7c7b<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u3001\u963b\u5c3c\u5757\u7c7b<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u5851\u6599\u4ef6<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u53d1\u6ce1\u7c7b<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u6a61\u80f6\u4ef6<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90\u7ebf\u53ca\u8fde\u63a5\u7ebf<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u5370\u5237\u7535\u8def\u677f\u53ca\u7535\u5668\u5143\u5668\u4ef6<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u5370\u5237\u4ef6<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u5668<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u5176\u4ed6\u5bc6\u5c01\u7c7b<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<tr>\n<td>\u5176\u4ed6\u5370\u8bb0\u7c7b<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<td>\u25cb<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"alert alert-note\">\n  <span class=\"label\">\u73af\u4fdd\u63d0\u793a<\/span><\/p>\n<ul>\n<li>\u660e\u7ec6\u4e2d\u7684\u90e8\u4ef6\u4e3a\u4e0d\u540c\u578b\u53f7\u6240\u5305\u542b\u7684\u4e3b\u8981\u90e8\u4ef6\u6c47\u603b\uff0c\u672c\u4ea7\u54c1\u662f\u5426\u5305\u542b\u8be5\u90e8\u4ef6\u4ee5\u4ea7\u54c1\u7684\u5b9e\u9645\u914d\u7f6e\u4e3a\u51c6\u3002<\/li>\n<li>\u4e0a\u8868\u4e2d\u6253\"\u00d7\"\u7684\u90e8\u4ef6\uff0c\u7531\u4e8e\u6280\u672f\u539f\u56e0\u76ee\u524d\u65e0\u6cd5\u5b9e\u73b0\u66ff\u4ee3\uff0c\u540e\u7eed\u968f\u7740\u6280\u672f\u4e0a\u7684\u8fdb\u6b65\u5c06\u9010\u6e10\u6539\u8fdb\u3002<\/li>\n<li>\u4e3a\u4e86\u4fdd\u62a4\u73af\u5883\u53ca\u4eba\u7c7b\u5065\u5eb7\uff1a\u672c\u4ea7\u54c1\u62a5\u5e9f\u540e\u8bf7\u4e0e\u751f\u6d3b\u5783\u573e\u5206\u5f00\uff0c\u6d88\u8d39\u8005\u6709\u8d23\u4efb\u5c06\u5176\u9001\u81f3\u6709\u8d44\u8d28\u7684\u56de\u6536\u70b9\uff1b\u56de\u6536\u5904\u7406\u4e2d\u5fc3\u5c06\u901a\u8fc7\u9002\u5f53\u7684\u65b9\u6cd5\u56de\u6536\u518d\u5229\u7528\u4ea7\u54c1\u4e2d\u7684\u6750\u6599\uff1b\u73af\u4fdd\u4f7f\u7528\u671f\u9650\u5230\u671f\u540e\u8bf7\u53ca\u65f6\u8054\u7cfb\u5f53\u5730\u7ecf\u9500\u5546\u6216\u670d\u52a1\u5546\u8fdb\u884c\u66f4\u6362\u3002<\/li>\n<\/ul>\n<\/div>\n<hr class=\"section-sep\">\n<p><!-- ====== \u88c5\u7bb1\u5355 \/ \u5408\u683c\u8bc1 \/ \u4e8c\u7ef4\u7801 ====== --><\/p>\n<h2>\u88c5\u7bb1\u5355<\/h2>\n<ul>\n<li>\u6c34\u6a21\u5757\uff1a1 \u53f0<\/li>\n<li>\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66\uff1a1 \u518c<\/li>\n<li>\u9644\u4ef6\u76d2\uff1a2 \u4e2a<\/li>\n<\/ul>\n<hr class=\"section-sep\">\n<h2>\u4ea7\u54c1\u5408\u683c\u8bc1 &amp; \u670d\u52a1\u4fe1\u606f<\/h2>\n<figure>\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4ea7\u54c1\u5408\u683c\u8bc1.jpg\" alt=\"\u4ea7\u54c1\u5408\u683c\u8bc1\"><figcaption>\u56fe\uff1a\u4ea7\u54c1\u5408\u683c\u8bc1<\/figcaption><\/figure>\n<div class=\"spec-card\">\n<p><strong>\u9752\u5c9b\u6d77\u4fe1\u65e5\u7acb\u7a7a\u8c03\u7cfb\u7edf\u6709\u9650\u516c\u53f8<\/strong><\/p>\n<p>\u5730\u5740\uff1a\u9752\u5c9b\u7ecf\u6d4e\u6280\u672f\u5f00\u53d1\u533a\u524d\u6e7e\u6e2f\u8def 218 \u53f7 &nbsp; | &nbsp; \u90ae\u7f16\uff1a266510<\/p>\n<p>\u5ba2\u6237\u670d\u52a1\u70ed\u7ebf\uff1a400-860-1111<\/p>\n<p>\u7535\u5b50\u90ae\u4ef6\uff1ahhcsc@hisensehitachi.com<\/p>\n<p>\u5b98\u7f51\uff1ahttp:\/\/www.hisensehitachi.com<\/p>\n<\/div>\n<div class=\"qr-row\" style=\"display:flex; justify-content:center; gap:40px; flex-wrap:wrap; margin:20px 0;\">\n<figure style=\"margin:0;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u65e5\u7acb\u670d\u52a1\u4e8c\u7ef4\u7801.jpg\" alt=\"\u65e5\u7acb\u670d\u52a1\u4e8c\u7ef4\u7801\" style=\"width:140px;\"><figcaption>\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u670d\u52a1<\/figcaption><\/figure>\n<figure style=\"margin:0;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u65e5\u7acb\u5b98\u65b9\u5fae\u4fe1\u4e8c\u7ef4\u7801.jpg\" alt=\"\u65e5\u7acb\u5b98\u65b9\u5fae\u4fe1\u4e8c\u7ef4\u7801\" style=\"width:140px;\"><figcaption>\u65e5\u7acb\u5b98\u65b9\u5fae\u4fe1<\/figcaption><\/figure>\n<\/div>\n<p style=\"text-align:center; margin-top:8px;\">* \u672c\u516c\u53f8\u81f4\u529b\u4e8e\u4e0d\u65ad\u5730\u5bf9\u4ea7\u54c1\u8fdb\u884c\u6539\u8fdb\uff0c\u5982\u6709\u53d8\u66f4\u6055\u4e0d\u53e6\u884c\u901a\u77e5\u3002<\/p>\n<p><\/main><\/p>\n<footer>\n<p>N6010001156 &nbsp; 2026.01 V01 &nbsp; | &nbsp; \u672c\u8bf4\u660e\u4e66\u4e3a\u6c34\u6a21\u5757\u4e13\u7528\u8bf4\u660e\u4e66\uff0c\u8bf7\u540c\u65f6\u9605\u8bfb\u4e0e\u4e4b\u5339\u914d\u7684\u5ba4\u5916\u673a\u8bf4\u660e\u4e66<\/p>\n<\/footer>\n","protected":false},"excerpt":{"rendered":"<p>\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 \u6c34\u6a21\u5757\u673a\u7ec4 WATER [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3183","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=3183\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 \u6c34\u6a21\u5757\u673a\u7ec4 WATER [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=3183\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-09T17:06:56+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3183\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3183\",\"name\":\"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\\\/ 224 \\\/ 280 \\\/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-13T11:06:31+00:00\",\"dateModified\":\"2026-11-09T17:06:56+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3183#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3183\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3183#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\\\/ 224 \\\/ 280 \\\/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=3183","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 \u6c34\u6a21\u5757\u673a\u7ec4 WATER [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=3183","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-09T17:06:56+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"10 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=3183","url":"https:\/\/longmai-nt.com\/?page_id=3183","name":"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-13T11:06:31+00:00","dateModified":"2026-11-09T17:06:56+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=3183#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=3183"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=3183#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u65e5\u7acb\u5168\u6548\u6c34\u6a21\u5757RWMG-160\/ 224 \/ 280 \/335FWXNZQ\u5b89\u88c5\u53ca\u4fdd\u517b\u8bf4\u660e\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3183","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3183"}],"version-history":[{"count":5,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3183\/revisions"}],"predecessor-version":[{"id":19559,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3183\/revisions\/19559"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3183"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}