{"id":3246,"date":"2026-06-14T14:07:47","date_gmt":"2026-06-14T06:07:47","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=3246"},"modified":"2026-10-23T17:41:33","modified_gmt":"2026-10-23T09:41:33","slug":"%e4%bb%81%e5%92%8c%e8%a1%9739%e5%8f%b7%e9%99%a2-%c2%b7-%e5%b8%b8%e8%80%81%e5%b8%88%e6%9a%97%e5%9f%8b%e6%9a%96%e6%b0%94%e7%89%87-%e6%a1%a3%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=3246","title":{"rendered":"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66"},"content":{"rendered":"\n\n<style>\n  :root {\n    --primary: #6b1d1d;\n    --accent: #c0392b;\n    --accent-light: #e74c3c;\n    --bg: #f8f9fa;\n    --card-bg: #fff;\n    --text: #2c3e50;\n    --text-light: #5d6d7e;\n    --border: #dee2e6;\n    --highlight: #fdf2f2;\n    --success: #27ae60;\n    --warn: #e67e22;\n  }\n  * { box-sizing: border-box; margin: 0; padding: 0; }\n  body {\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", \"PingFang SC\", \"Microsoft YaHei\", sans-serif;\n    color: var(--text); background: var(--bg);\n    line-height: 1.8; font-size: 15px;\n  }\n  .cover {\n    background: linear-gradient(135deg, #6b1d1d 0%, #922b21 30%, #c0392b 70%, #e74c3c 100%);\n    color: #fff; text-align: center;\n    padding: 80px 40px 60px; position: relative; overflow: hidden;\n  }\n  .cover::before { content:''; position:absolute; top:-100px; right:-100px; width:400px; height:400px; border:2px solid rgba(255,255,255,0.1); border-radius:50%; }\n  .cover::after  { content:''; position:absolute; bottom:-80px; left:-80px;  width:300px; height:300px; border:2px solid rgba(255,255,255,0.08); border-radius:50%; }\n  .cover .brand { font-size:14px; letter-spacing:4px; opacity:0.7; margin-bottom:20px; text-transform:uppercase; }\n  .cover h1 { font-size:32px; font-weight:700; margin-bottom:12px; }\n  .cover .subtitle { font-size:18px; opacity:0.85; margin-bottom:10px; }\n  .cover .system-tag { font-size:14px; opacity:0.7; margin-bottom:30px; }\n  .cover .tags { display:flex; flex-wrap:wrap; justify-content:center; gap:10px; margin-bottom:30px; }\n  .cover .tag { display:inline-block; padding:4px 14px; border-radius:16px; font-size:12px; background:rgba(255,255,255,0.15); border:1px solid rgba(255,255,255,0.25); }\n  .cover .meta { display:inline-flex; flex-wrap:wrap; justify-content:center; gap:30px; font-size:14px; opacity:0.75; }\n  .cover .meta span strong { display:block; font-size:13px; opacity:0.6; margin-top:2px; }\n\n  .container { max-width:1000px; margin:0 auto; padding:0 20px; }\n\n  .toc-wrapper { background:var(--card-bg); padding:40px; margin:30px auto; border-radius:12px; box-shadow:0 2px 12px rgba(0,0,0,0.06); }\n  .toc-wrapper h2 { color:var(--primary); font-size:24px; margin-bottom:24px; padding-bottom:12px; border-bottom:2px solid var(--accent); }\n  .toc-stage { margin-bottom:24px; }\n  .toc-stage-title { font-size:18px; font-weight:700; color:var(--primary); padding:8px 16px; background:var(--highlight); border-radius:6px; margin-bottom:10px; display:block; }\n  .toc-list { list-style:none; padding-left:20px; }\n  .toc-list li { margin:4px 0; }\n  .toc-list a { color:var(--accent); text-decoration:none; font-size:14px; transition:color 0.2s; }\n  .toc-list a:hover { color:var(--primary); text-decoration:underline; }\n  .toc-sub { padding-left:24px; list-style:none; }\n  .toc-sub a { font-size:13px; color:var(--text-light); }\n  .toc-sub-sub { padding-left:20px; }\n  .toc-sub-sub a { font-size:12.5px; color:#7f8c8d; }\n\n  .stage-header { background:linear-gradient(135deg, var(--primary), var(--accent)); color:#fff; padding:30px 40px; margin:40px 0 20px; border-radius:12px; }\n  .stage-header h2 { font-size:24px; margin-bottom:6px; }\n  .stage-header .stage-label { font-size:13px; opacity:0.7; letter-spacing:2px; text-transform:uppercase; }\n  section { background:var(--card-bg); margin:20px 0; padding:32px 40px; border-radius:10px; box-shadow:0 1px 6px rgba(0,0,0,0.05); }\n  section h3 { font-size:20px; color:var(--primary); margin-bottom:16px; padding-bottom:8px; border-bottom:1px solid var(--border); }\n  section h4 { font-size:16px; color:var(--accent); margin:20px 0 12px; }\n  section h5 { font-size:14px; color:var(--text); margin:16px 0 8px; font-weight:600; }\n  section p { margin:8px 0; color:var(--text-light); }\n\n  .table-wrap { overflow-x:auto; margin:16px 0; }\n  table { width:100%; border-collapse:collapse; font-size:13.5px; }\n  thead { background:var(--primary); color:#fff; }\n  thead th { padding:10px 12px; text-align:left; font-weight:600; white-space:nowrap; }\n  tbody td { padding:9px 12px; border-bottom:1px solid var(--border); }\n  tbody tr:nth-child(even) { background:var(--highlight); }\n  tbody tr:hover { background:#f5b7b1; }\n  .subtotal-row td { font-weight:700; background:#fdedec; border-top:2px solid var(--success); }\n  .total-row td { font-weight:700; font-size:15px; background:#d5f5e3; }\n\n  .info-card { background:var(--highlight); border-left:4px solid var(--accent); padding:16px 20px; margin:16px 0; border-radius:0 8px 8px 0; }\n  .info-card p { margin:4px 0; }\n  .info-card .label { font-weight:700; color:var(--primary); min-width:100px; display:inline-block; }\n  .commitment-card { background:linear-gradient(135deg, #fdedec, #fdebd0); border:1px solid #f5b7b1; padding:20px; margin:16px 0; border-radius:8px; }\n  .commitment-item { display:flex; gap:10px; margin:8px 0; align-items:flex-start; }\n  .commitment-item .check { color:var(--success); font-size:18px; flex-shrink:0; }\n  .highlight-box { background:linear-gradient(135deg, #fef9e7, #fdebd0); border:1px solid #f5b041; padding:20px; margin:16px 0; border-radius:8px; }\n  blockquote { background:#fdf2e9; border-left:4px solid var(--warn); padding:12px 16px; margin:12px 0; border-radius:0 6px 6px 0; font-style:italic; color:#7d6608; }\n  .empty-data { color:#95a5a6; font-style:italic; padding:8px 16px; }\n\n  .survey-gallery { display:grid; grid-template-columns:repeat(2, 1fr); gap:16px; margin:16px 0; }\n  .survey-gallery figure { margin:0; background:var(--card-bg); border:1px solid var(--border); border-radius:8px; overflow:hidden; transition:transform 0.2s, box-shadow 0.2s; }\n  .survey-gallery figure:hover { transform:translateY(-2px); box-shadow:0 4px 16px rgba(0,0,0,0.12); }\n  .survey-gallery img { width:100%; height:auto; display:block; object-fit:cover; aspect-ratio:4\/3; }\n  .survey-gallery figcaption { padding:8px 12px; font-size:13px; color:var(--text-light); text-align:center; background:#fafafa; }\n  @media (max-width:640px) { .survey-gallery { grid-template-columns:1fr; } }\n\n  .badge { display:inline-block; padding:2px 10px; border-radius:12px; font-size:12px; font-weight:600; }\n  .badge-primary { background:var(--accent); color:#fff; }\n  .badge-success { background:var(--success); color:#fff; }\n  .badge-heat { background:var(--accent-light); color:#fff; }\n\n  .valve-grid { display:grid; grid-template-columns:1fr 1fr; gap:16px; margin:16px 0; }\n  .valve-card { background:var(--highlight); border-radius:8px; padding:20px; border:1px solid var(--border); }\n  .valve-card h5 { color:var(--primary); margin-bottom:8px; font-size:15px; }\n  .valve-card .icon { font-size:28px; margin-bottom:8px; }\n\n  .flow-steps { display:flex; flex-wrap:wrap; gap:12px; margin:16px 0; }\n  .flow-step { flex:1; min-width:100px; text-align:center; background:var(--highlight); border-radius:8px; padding:16px 12px; border:1px solid var(--border); }\n  .flow-step .step-num { width:32px; height:32px; border-radius:50%; background:var(--accent); color:#fff; display:inline-flex; align-items:center; justify-content:center; font-weight:700; font-size:14px; margin-bottom:8px; }\n  .flow-step .step-title { font-size:13px; font-weight:600; color:var(--primary); }\n  .flow-step .step-desc { font-size:11px; color:var(--text-light); margin-top:4px; }\n\n  footer { text-align:center; padding:40px 20px; color:var(--text-light); font-size:13px; border-top:1px solid var(--border); margin-top:40px; }\n  footer p { margin:4px 0; }\n  .back-to-top { display:inline-block; margin-top:16px; padding:8px 24px; background:var(--accent); color:#fff; border-radius:20px; text-decoration:none; font-size:13px; }\n\n  @media print { body { background:#fff; font-size:12px; } .cover { padding:40px; } section { box-shadow:none; border-bottom:1px solid #ccc; break-inside:avoid; } .back-to-top { display:none; } }\n<\/style>\n\n<!-- ============ COVER ============ -->\n<div class=\"cover\">\n  <div class=\"brand\">\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u4e13\u6ce8\u53ef\u89c6\u5316\u670d\u52a1<\/div>\n  <h1>\ud83d\udd25 \u6697\u57cb\u6696\u6c14\u7247 \u00b7 \u7ecf\u5178\u6848\u4f8b<\/h1>\n  <div class=\"subtitle\">\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u96c5\u5c45<\/div>\n  <div class=\"system-tag\">\u66fc\u745e\u5fb7 L1B24-Heidelberg Min.5 + \u5f02\u7a0b\u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf<\/div>\n  <div class=\"tags\">\n    <span class=\"tag\">\ud83d\udd25 \u66fc\u745e\u5fb7 L1B24-Heidelberg Min.5<\/span>\n    <span class=\"tag\">\ud83d\udd27 \u5355\u72ec\u9600\u95e8\u63a7\u5236<\/span>\n    <span class=\"tag\">\ud83c\udfe1 \u6697\u57cb\u6696\u6c14\u7247<\/span>\n    <span class=\"tag\">\ud83d\udcb0 \u900f\u660e\u9884\u7b97<\/span>\n    <span class=\"tag\">\ud83d\udd17 \u5f02\u7a0b\u8fde\u63a5<\/span>\n    <span class=\"tag\">\ud83c\udfe1 33.6\u33a1\u91c7\u6696\u9762\u79ef<\/span>\n  <\/div>\n  <div class=\"meta\">\n    <span>\u6863\u6848\u7f16\u53f7<br><strong>R-B-H-002<\/strong><\/span>\n    <span>\u623f\u5c4b\u9762\u79ef<br><strong>~55\u33a1<\/strong><\/span>\n    <span>\u91c7\u6696\u9762\u79ef<br><strong>33.6\u33a1<\/strong><\/span>\n    <span>\u5ba2\u6237\u7c7b\u578b<br><strong>\u8001\u5ba2\u6237\u590d\u8d2d<\/strong><\/span>\n    <span>\u7f16\u5236\u65e5\u671f<br><strong>2026\u5e746\u670814\u65e5<\/strong><\/span>\n    <span>\u7248\u672c<br><strong>V1.0\uff08\u6863\u6848\u7248\uff09<\/strong><\/span>\n  <\/div>\n<\/div>\n\n<div class=\"container\">\n\n<!-- ============ CUSTOMER SUCCESS TARGET ============ -->\n<div class=\"info-card\">\n  <p><strong style=\"color:var(--primary);\">\ud83c\udfaf \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/strong><\/p>\n  <p>\u4e3a\u5e38\u8001\u5e08\u6bcd\u4eb2\u4f4f\u5b85\u4ea4\u4ed8\u4e00\u5957\u5b89\u5168\u3001\u6696\u548c\u3001\u7701\u5fc3\u7684\u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf\u300233.6\u33a1\u91c7\u6696\u9762\u79ef\uff0c\u4e24\u4f4d60+\u5c81\u8001\u4eba\u6e29\u6696\u8fc7\u51ac\uff0c\u9002\u8001\u5316\u914d\u7f6e\u786e\u4fdd\u70ed\u503c\u5145\u8db3\u3001\u64cd\u4f5c\u7b80\u5355\u3001\u5b89\u5168\u65e0\u5fe7\u3002\u8001\u5ba2\u6237\u4fe1\u8d56\u590d\u8d2d\uff0c\u5168\u7a0b\u900f\u660e\u53ef\u8ffd\u6eaf\u3002<\/p>\n<\/div>\n\n<!-- ============ TABLE OF CONTENTS ============ -->\n<div class=\"toc-wrapper\" id=\"top\">\n  <h2>\ud83d\udccb \u5b8c\u6574\u76ee\u5f55<\/h2>\n\n  <!-- \u4e00\u9636\u6bb5 -->\n  <div class=\"toc-stage\">\n    <span class=\"toc-stage-title\">\u4e00\u9636\u6bb5\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1\uff08\u65b9\u6848\u524d\u4e66\uff09<\/span>\n    <ul class=\"toc-list\">\n      <li><a href=\"#rhjcls01\">1. \u9700\u6c42\u7406\u89e3<\/a><\/li>\n      <li><a href=\"#rhjcls02\">2. \u914d\u7f6e\u603b\u89c8<\/a><\/li>\n      <li>\n        <a href=\"#rhjcls03\">3. \u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf<\/a>\n        <ul class=\"toc-sub\">\n          <li><a href=\"#rhjcls0301\">3.1 \u914d\u7f6e\u6e05\u5355<\/a><\/li>\n          <li><a href=\"#rhjcls0302\">3.2 \u6838\u5fc3\u53c2\u6570<\/a><\/li>\n          <li><a href=\"#rhjcls0303\">3.3 \u62a5\u4ef7\u660e\u7ec6<\/a><\/li>\n        <\/ul>\n      <\/li>\n      <li><em style=\"color:#95a5a6; font-size:13px;\">\uff08\u672c\u65b9\u6848\u65e0\u5730\u6696\/\u65b0\u98ce\u7cfb\u7edf\uff0c\u5bf9\u5e94\u7ae0\u8282\u5df2\u7701\u7565\uff09<\/em><\/li>\n      <li><a href=\"#rhjcls06\">4. \u4f1a\u5458\u6743\u76ca<\/a><\/li>\n      <li><a href=\"#rhjcls07\">5. \u4e13\u9879\u627f\u8bfa<\/a><\/li>\n      <li><a href=\"#rhjcls08\">6. \u7b7e\u7ea6\u540e\u6743\u76ca<\/a><\/li>\n      <li><a href=\"#rhjcls09\">7. \u670d\u52a1\u627f\u8bfa<\/a><\/li>\n      <li><a href=\"#rhjcls10\">8. \u603b\u7ed3<\/a><\/li>\n    <\/ul>\n  <\/div>\n\n  <!-- \u4e8c\u9636\u6bb5 -->\n  <div class=\"toc-stage\">\n    <span class=\"toc-stage-title\">\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/span>\n    <ul class=\"toc-list\">\n      <li>\n        <a href=\"#rhjcls11\">1. \u6982\u8ff0\uff1a\u6750\u6599\u6e05\u5355\u53ca\u8bbe\u8ba1\u8bf4\u660e<\/a>\n        <ul class=\"toc-sub\">\n          <li><a href=\"#rhjcls1101\">1.1 \u914d\u7f6e\u6750\u6599\u6e05\u5355<\/a><\/li>\n          <li><a href=\"#rhjcls1102\">1.2 \u8bbe\u8ba1\u4f9d\u636e<\/a><\/li>\n          <li><a href=\"#rhjcls1103\">1.3 \u5907\u6ce8\u8bf4\u660e<\/a><\/li>\n        <\/ul>\n      <\/li>\n      <li>\n        <a href=\"#rhjcls12\">2. \u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de56\u6b65\u6cd5+2<\/a>\n        <ul class=\"toc-sub\">\n          <li><a href=\"#rhjcls1201\">2.1 \u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/a><\/li>\n          <li><a href=\"#rhjcls1202\">2.2 \u7b2c\u4e8c\u6b65\uff1a\u8bbe\u8ba1\u51fa\u56fe<\/a><\/li>\n          <li><a href=\"#rhjcls1203\">2.3 \u7b2c\u4e09\u6b65\uff1a\u9690\u853d\u5de5\u7a0b\u7cbe\u5de56\u6b65\u6cd5<\/a><\/li>\n          <li><a href=\"#rhjcls1204\">2.4 \u7b2c\u56db\u6b65\uff1a\u76d1\u7406\u5230\u4f4d<\/a><\/li>\n          <li><a href=\"#rhjcls1205\">2.5 \u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/a><\/li>\n          <li><a href=\"#rhjcls1206\">2.6 \u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536<\/a><\/li>\n          <li><a href=\"#rhjcls1207\">2.7 +1\uff1a\u4ea4\u4ed8\u6559\u5b66\uff08\u542b\u64cd\u4f5c\u8981\u70b9\u901f\u67e5\uff09<\/a><\/li>\n          <li><a href=\"#rhjcls1208\">2.8 +2\uff1a\u552e\u540e\u4fdd\u969c\uff08\u542b\u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355\uff09<\/a><\/li>\n        <\/ul>\n      <\/li>\n    <\/ul>\n  <\/div>\n\n  <!-- \u4e09\u9636\u6bb5 -->\n  <div class=\"toc-stage\">\n    <span class=\"toc-stage-title\">\u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3<\/span>\n    <ul class=\"toc-list\">\n      <li><a href=\"#rhjcls13\">1. \u5ba2\u6237\u53cd\u9988<\/a><\/li>\n      <li>\n        <a href=\"#rhjcls14\">2. \u8fd0\u884c\u8bb0\u5f55\u4e0e\u89e3\u6790<\/a>\n        <ul class=\"toc-sub\">\n          <li><a href=\"#rhjcls1401\">2.1 \u8fd0\u884c\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa<\/a><\/li>\n          <li><a href=\"#rhjcls1402\">2.2 \u6570\u636e\u57fa\u51c6<\/a><\/li>\n          <li><a href=\"#rhjcls1403\">2.3 \u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55<\/a><\/li>\n          <li><a href=\"#rhjcls1404\">2.4 \u8fd0\u884c\u5bf9\u6807\u57fa\u51c6<\/a><\/li>\n        <\/ul>\n      <\/li>\n      <li><a href=\"#rhjcls15\">3. \u552e\u540e\u670d\u52a1\u8bb0\u5f55\u4e0e\u89e3\u6790<\/a><\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<!-- ============================================================ -->\n<!-- \u4e00\u9636\u6bb5\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1\uff08\u65b9\u6848\u524d\u4e66\uff09 -->\n<!-- ============================================================ -->\n<div class=\"stage-header\" id=\"stage1\">\n  <span class=\"stage-label\">\u7b2c\u4e00\u9636\u6bb5<\/span>\n  <h2>\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1\uff08\u65b9\u6848\u524d\u4e66\uff09<\/h2>\n<\/div>\n\n<!-- 1. \u9700\u6c42\u7406\u89e3 -->\n<section id=\"rhjcls01\">\n  <h3>1. \u9700\u6c42\u7406\u89e3<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u60a8\u8bf4\u7684<\/th><th>\u6211\u4eec\u7406\u89e3\u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\"\u6211\u5bb6\u6696\u6c14\u7247\u662f\u4f60\u5b89\u7684\uff0c\u6211\u5988\u5bb6\u4e5f\u8981\"<\/td><td>\u8001\u5ba2\u6237\u6df1\u5ea6\u4fe1\u8d56\uff0c\u65e0\u9700\u5bf9\u6bd4\u5373\u53ef\u51b3\u7b56\uff0c\u4fe1\u4efb\u662f\u6700\u597d\u7684\u9500\u552e<\/td><\/tr>\n        <tr><td>\"\u6328\u5230\u5f97\u4e0d\u5f97\u70eb\u8d77\u98de\uff1f\"\uff08\u6bcd\u4eb2\u62c5\u5fc3\uff09<\/td><td>\u8001\u5e74\u4eba\u5bf9\u6696\u6c14\u7247\u5b89\u5168\u6027\u6709\u987e\u8651\uff0c\u9700\u8981\u8868\u9762\u6e29\u5ea6\u5b89\u5168\u63a7\u5236\uff0c\u63a5\u89e6\u4e0d\u70eb\u4f24<\/td><\/tr>\n        <tr><td>\"\u6bcd\u4eb2\u5e74\u7eaa\u5927\u4e86\uff0c\u6015\u51b7\"<\/td><td>\u8001\u5e74\u4eba\u5bf9\u6e29\u5ea6\u66f4\u654f\u611f\uff0c\u70ed\u503c\u914d\u7f6e\u5fc5\u987b\u5145\u8db3\uff0c\u786e\u4fdd\u6bcf\u4e2a\u623f\u95f4\u6696\u548c\u5230\u4f4d<\/td><\/tr>\n        <tr><td>\"\u542c\u4f60\u5b89\u6392\uff0c\u4f60\u662f\u4e13\u4e1a\u7684\"<\/td><td>\u5ba2\u6237\u5b89\u5fc3\u8ddf\u968f\uff0c\u9500\u552e\u5168\u7a0b\u4e3b\u5bfc\uff0c\u5feb\u901f\u51b3\u7b56\u3001\u5feb\u901f\u65bd\u5de5<\/td><\/tr>\n        <tr><td>\"\u5c3d\u91cf\u4e0d\u8981\u5f71\u54cd\u8001\u4eba\u751f\u6d3b\"<\/td><td>\u5c0f\u6237\u578b\u6697\u57cb\u65b9\u6848\uff0c\u65bd\u5de5\u5468\u671f1-2\u5929\uff0c\u65e0\u9700\u642c\u51fa\uff0c\u4e0d\u6270\u8001\u4eba\u751f\u6d3b<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"commitment-card\">\n    <h4>\u672c\u65b9\u6848\u7684\u6838\u5fc3\u627f\u8bfa<\/h4>\n    <div class=\"commitment-item\"><span class=\"check\">\u2705<\/span><span><strong>\u6696\u548c<\/strong>\uff1a\u5ba2\u5385C33\u52a0\u539a\u578b+\u5367\u5ba4C22\u4f4e\u77ee\u578b\uff0c\u70ed\u503c\u8d85\u914d\uff0c\u8001\u5e74\u4eba\"\u591a\u7ed9\u4e00\u70b9\u6e29\u6696\"<\/span><\/div>\n    <div class=\"commitment-item\"><span class=\"check\">\u2705<\/span><span><strong>\u5b89\u5168<\/strong>\uff1a\u6696\u6c14\u7247\u8868\u9762\u6e29\u5ea6\u5b89\u5168\u63a7\u5236\uff0c\u63a5\u89e6\u4e0d\u70eb\u4f24\uff0c\u8ba9\u8001\u4eba\u7528\u5f97\u653e\u5fc3<\/span><\/div>\n    <div class=\"commitment-item\"><span class=\"check\">\u2705<\/span><span><strong>\u7b80\u5355<\/strong>\uff1a\u72ec\u7acb\u7403\u9600\u63a7\u5236\uff0c\u64cd\u4f5c\u76f4\u89c2\uff0c\u8001\u5e74\u4eba\u4e5f\u80fd\u8f7b\u677e\u638c\u63a7<\/span><\/div>\n    <div class=\"commitment-item\"><span class=\"check\">\u2705<\/span><span><strong>\u5feb\u901f<\/strong>\uff1a\u6697\u57cb\u65b9\u68481-2\u5929\u5b8c\u5de5\uff0c\u4e0d\u642c\u5bb6\u5177\u3001\u4e0d\u6270\u751f\u6d3b<\/span><\/div>\n    <div class=\"commitment-item\"><span class=\"check\">\u2705<\/span><span><strong>\u4fdd\u969c<\/strong>\uff1a\u8001\u5ba2\u6237\u590d\u8d2d\uff0c\u9f99\u8109\u5168\u7a0b\u8d1f\u8d23\uff0c\u6863\u6848\u53ef\u8ffd\u6eaf<\/span><\/div>\n  <\/div>\n<\/section>\n\n<!-- 2. \u914d\u7f6e\u603b\u89c8 -->\n<section id=\"rhjcls02\">\n  <h3>2. \u914d\u7f6e\u603b\u89c8<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u7cfb\u7edf<\/th><th>\u914d\u7f6e<\/th><th>\u6838\u5fc3\u7279\u70b9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td><strong>\u70ed\u6e90<\/strong><\/td><td>\u66fc\u745e\u5fb7 L1B24-Heidelberg Min.5 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/td><td>\u5fb7\u7cfb\u54c1\u8d28\uff0c24kW\u4e24\u7528\u7089\uff0c\u5206\u6bb5\u71c3\u70e7\u7cbe\u51c6\u63a7\u6e29<\/td><\/tr>\n        <tr><td><strong>\u672b\u7aef<\/strong><\/td><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247 \u00d7 2\u7ec4\uff08\u5ba2\u5385C33\u52a0\u539a\u578b + \u5367\u5ba4C22\u4f4e\u77ee\u578b\uff09<\/td><td>\u9002\u8001\u5316\u914d\u7f6e\uff0c\u70ed\u503c\u5145\u8db3\uff0c\u6cbf\u7a97\u53f0\u4e0b\u5b89\u88c5\u7f8e\u89c2\u6574\u6d01<\/td><\/tr>\n        <tr><td><strong>\u8fde\u63a5<\/strong><\/td><td>\u5f02\u7a0b\u8fde\u63a5\uff08\u65e0\u5206\u96c6\u6c34\u5668\uff09<\/td><td>\u7ba1\u8def\u7b80\u6d01\u3001\u65bd\u5de5\u65b9\u4fbf\u3001\u6210\u672c\u66f4\u4f18<\/td><\/tr>\n        <tr><td><strong>\u63a7\u5236<\/strong><\/td><td>\u72ec\u7acb\u9ec4\u94dc\u7403\u9600 + \u624b\u52a8\u6e29\u63a7\u9600<\/td><td>\u5404\u7ec4\u72ec\u7acb\u63a7\u5236\uff0c\u64cd\u4f5c\u7b80\u5355\uff0c\u65e0\u7535\u5b50\u4f9d\u8d56<\/td><\/tr>\n        <tr><td><strong>\u7ba1\u9053<\/strong><\/td><td>PPR\u70ed\u6c34\u7ba1 + \u534e\u7f8e\u4fdd\u6e29\u7ba1\u6697\u57cb\u6577\u8bbe<\/td><td>\u8010\u9ad8\u6e29\u3001\u6297\u8001\u5316\u3001\u70ed\u635f\u5931\u5c0f<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- 3. \u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf -->\n<section id=\"rhjcls03\">\n  <h3>3. \u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf\uff08\u66fc\u745e\u5fb7\u9505\u7089 + \u5f02\u7a0b\u8fde\u63a5\uff09<\/h3>\n\n  <!-- 3.1 -->\n  <h4 id=\"rhjcls0301\">3.1 \u914d\u7f6e\u6e05\u5355<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u533a\u57df<\/th><th>\u8bbe\u5907\/\u6750\u6599<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u7279\u70b9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5ba2\u5385<\/td><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247<\/td><td>C33\u52a0\u539a\u578b 900\u00d71000mm<\/td><td>1\u7ec4<\/td><td>\u6563\u70ed\u91cf\u66f4\u5145\u8db3\uff0c\u9002\u8001\u5316\u914d\u7f6e\u786e\u4fdd\u6696\u548c<\/td><\/tr>\n        <tr><td>\u5367\u5ba4<\/td><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247<\/td><td>C22 300\u00d71400mm<\/td><td>1\u7ec4<\/td><td>300mm\u4f4e\u77ee\u578b\u6cbf\u7a97\u53f0\u4e0b\u5b89\u88c5\uff0c\u8282\u7701\u7a7a\u95f4\u7f8e\u89c2\u6574\u6d01<\/td><\/tr>\n        <tr><td>\u70ed\u6e90<\/td><td>\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/td><td>\u66fc\u745e\u5fb7 L1B24-Heidelberg Min.5<\/td><td>1\u53f0<\/td><td>\u5fb7\u7cfb\u54c1\u8d28\uff0c24kW\u4e24\u7528\u7089\uff0c\u5206\u6bb5\u71c3\u70e7<\/td><\/tr>\n        <tr><td>\u9600\u95e8<\/td><td>\u9ec4\u94dc\u7403\u9600 + \u6e29\u63a7\u9600<\/td><td>\u54c1\u724c\u5b9a\u5236<\/td><td>\u6309\u9700<\/td><td>\u6bcf\u7ec4\u6696\u6c14\u7247\u72ec\u7acb\u63a7\u5236\uff0c\u624b\u52a8\u8c03\u6e29<\/td><\/tr>\n        <tr><td>\u7ba1\u8def<\/td><td>PPR\u70ed\u6c34\u7ba1 + \u4fdd\u6e29\u5957\u7ba1<\/td><td>\u534e\u7f8e\u4fdd\u6e29\u7ba1<\/td><td>1\u5957<\/td><td>\u6697\u57cb\u6577\u8bbe\uff0c\u5f02\u7a0b\u8fde\u63a5\uff0c\u70ed\u635f\u5931\u5c0f<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 3.2 -->\n  <h4 id=\"rhjcls0302\">3.2 \u6838\u5fc3\u53c2\u6570<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u5bf9\u60a8\u7684\u4ef7\u503c<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u9505\u7089\u578b\u53f7<\/td><td>\u66fc\u745e\u5fb7 L1B24-Heidelberg Min.5<\/td><td>\u5fb7\u7cfb\u54c1\u724c\uff0c\u54c1\u8d28\u4fdd\u969c<\/td><\/tr>\n        <tr><td>\u9505\u7089\u529f\u7387<\/td><td>24 kW<\/td><td>\u6ee1\u8db333.6\u33a1\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\u9700\u6c42<\/td><\/tr>\n        <tr><td>\u71c3\u70e7\u65b9\u5f0f<\/td><td>\u5206\u6bb5\u71c3\u70e7<\/td><td>\u7cbe\u51c6\u63a7\u6e29\uff0c\u8282\u80fd\u7701\u6c14<\/td><\/tr>\n        <tr><td>\u5ba2\u5385\u6696\u6c14\u7247<\/td><td>C33\u52a0\u539a\u578b 900\u00d71000mm<\/td><td>\u6563\u70ed\u91cf\u5145\u8db3\uff0c\u8001\u5e74\u4eba\u66f4\u6696\u548c<\/td><\/tr>\n        <tr><td>\u5367\u5ba4\u6696\u6c14\u7247<\/td><td>C22 300\u00d71400mm<\/td><td>\u4f4e\u77ee\u578b\u4e0d\u5360\u7a7a\u95f4\uff0c\u6cbf\u7a97\u53f0\u7f8e\u89c2\u5b89\u88c5<\/td><\/tr>\n        <tr><td>\u8fde\u63a5\u65b9\u5f0f<\/td><td>\u5f02\u7a0b\u8fde\u63a5<\/td><td>\u65e0\u9700\u5206\u96c6\u6c34\u5668\uff0c\u7ba1\u8def\u7b80\u6d01\uff0c\u6210\u672c\u66f4\u4f18<\/td><\/tr>\n        <tr><td>\u7ba1\u9053\u7cfb\u7edf<\/td><td>PPR\u70ed\u6c34\u7ba1\u6697\u57cb<\/td><td>\u8010\u9ad8\u6e29\u3001\u6297\u8001\u5316\u3001\u6697\u57cb\u7f8e\u89c2<\/td><\/tr>\n        <tr><td>\u63a7\u5236\u65b9\u5f0f<\/td><td>\u72ec\u7acb\u7403\u9600+\u624b\u52a8\u6e29\u63a7\u9600<\/td><td>\u64cd\u4f5c\u7b80\u5355\uff0c\u65e0\u7535\u5b50\u4f9d\u8d56\uff0c\u9002\u5408\u8001\u5e74\u4eba<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 3.3 -->\n  <h4 id=\"rhjcls0303\">3.3 \u62a5\u4ef7\u660e\u7ec6<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c\/\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7\uff08\u5143\uff09<\/th><th>\u5c0f\u8ba1\uff08\u5143\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u66fc\u745e\u5fb7\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/td><td>L1B24-Heidelberg Min.5<\/td><td>1\u53f0<\/td><td>\u2014<\/td><td>\u9762\u8bae<\/td><\/tr>\n        <tr><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247\uff08\u5ba2\u5385\uff09<\/td><td>C33\u52a0\u539a\u578b 900\u00d71000mm<\/td><td>1\u7ec4<\/td><td>\u2014<\/td><td>\u9762\u8bae<\/td><\/tr>\n        <tr><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247\uff08\u5367\u5ba4\uff09<\/td><td>C22 300\u00d71400mm<\/td><td>1\u7ec4<\/td><td>\u2014<\/td><td>\u9762\u8bae<\/td><\/tr>\n        <tr><td>PPR\u70ed\u6c34\u7ba1\u6697\u57cb\u7cfb\u7edf<\/td><td>\u70ed\u6c34\u7ba1+\u534e\u7f8e\u4fdd\u6e29\u7ba1<\/td><td>1\u5957<\/td><td>\u2014<\/td><td>\u9762\u8bae<\/td><\/tr>\n        <tr><td>\u9ec4\u94dc\u7403\u9600+\u6e29\u63a7\u9600<\/td><td>\u54c1\u724c\u5b9a\u5236<\/td><td>\u6309\u9700<\/td><td>\u2014<\/td><td>\u9762\u8bae<\/td><\/tr>\n        <tr><td>\u65bd\u5de5\u5b89\u88c5\u8d39<\/td><td>\u7cbe\u5de5\u516d\u6b65+2\u6807\u51c6<\/td><td>1\u9879<\/td><td>\u2014<\/td><td>\u542b\u6253\u5b54\/\u5e03\u7ba1\/\u8c03\u8bd5\/\u6559\u5b66<\/td><\/tr>\n        <tr class=\"subtotal-row\"><td colspan=\"4\"><strong>\u5408\u8ba1\uff08\u4f18\u60e0\u524d\uff09<\/strong><\/td><td><strong>\u9762\u8bae<\/strong><\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p>\u2705 \u542b\u8bbe\u5907\u3001\u5b89\u88c5\u3001\u6240\u6709\u8f85\u6750\uff0c\u900f\u660e\u62a5\u4ef7\u65e0\u9690\u5f62\u6d88\u8d39<\/p>\n  <p>\u2705 \u8001\u5ba2\u6237\u590d\u8d2d\u4e13\u5c5e\u4f18\u60e0\uff0c\u5177\u4f53\u9762\u8bae<\/p>\n<\/section>\n\n<!-- 4. \u4f1a\u5458\u6743\u76ca\uff08\u5bf9\u5e94\u6e56\u4e0e\u767d06\uff09-->\n<section id=\"rhjcls06\">\n  <h3>4. \u4f1a\u5458\u6743\u76ca <span class=\"badge badge-primary\">199\u5143\/\u5e74\uff0c\u9996\u5e74\u53ef\u7528\u6696\u901a\u91d1\u989d\u62b5\u6263<\/span><\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u6743\u76ca<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td>\u9505\u7089\u5ef6\u4fdd\u81f310\u5e74\uff08\u4ee5\u5382\u5bb6\u653f\u7b56\u4e3a\u51c6\uff09<\/td><\/tr>\n        <tr><td>\u670d\u52a1\u6298\u6263<\/td><td>\u6240\u6709\u670d\u52a1\u53ca\u8017\u67505-8\u6298<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8<\/td><td>\u4e0d\u9650\u6b21\u6570<\/td><\/tr>\n        <tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/td><\/tr>\n        <tr><td>10\u5e74\u8fd0\u884c\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u51fa\u5177\u8fd0\u884c\u5206\u6790\u62a5\u544a<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- 5. \u4e13\u9879\u627f\u8bfa -->\n<section id=\"rhjcls07\">\n  <h3>5. \u9488\u5bf9\u60a8\u75db\u70b9\u7684\u4e13\u9879\u627f\u8bfa<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u60a8\u7684\u75db\u70b9<\/th><th>\u6211\u4eec\u7684\u89e3\u51b3\u65b9\u6848<\/th><th>\u6548\u679c\u627f\u8bfa<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td><strong>\u6696\u6c14\u7247\u70eb\u4eba<\/strong><\/td><td>\u8868\u9762\u6e29\u5ea6\u5b89\u5168\u63a7\u5236\uff0c\u63a5\u89e6\u4e0d\u70eb\u4f24<\/td><td>\u8001\u4eba\u4f7f\u7528\u5b89\u5168\u65e0\u5fe7<\/td><\/tr>\n        <tr><td><strong>\u8001\u4eba\u4e0d\u4f1a\u64cd\u4f5c<\/strong><\/td><td>\u72ec\u7acb\u7403\u9600+\u624b\u52a8\u6e29\u63a7\u9600\uff0c\u64cd\u4f5c\u76f4\u89c2<\/td><td>\u8001\u5e74\u4eba\u4e5f\u80fd\u8f7b\u677e\u638c\u63a7<\/td><\/tr>\n        <tr><td><strong>\u70ed\u503c\u4e0d\u591f\u6696<\/strong><\/td><td>C33\u52a0\u539a\u578b\u8d85\u914d+\u5367\u5ba4C22\u4f4e\u77ee\u578b<\/td><td>\u6bcf\u4e2a\u623f\u95f4\u6696\u548c\u5230\u4f4d<\/td><\/tr>\n        <tr><td><strong>\u65bd\u5de5\u6270\u6c11<\/strong><\/td><td>\u6697\u57cb\u65b9\u68481-2\u5929\u5b8c\u5de5<\/td><td>\u4e0d\u642c\u5bb6\u5177\u3001\u4e0d\u6270\u8001\u4eba\u751f\u6d3b<\/td><\/tr>\n        <tr><td><strong>\u8001\u5ba2\u6237\u6ca1\u4fdd\u969c<\/strong><\/td><td>\u9f99\u810922\u5e74\u54c1\u724c+\u6863\u6848\u53ef\u8ffd\u6eaf<\/td><td>\u5168\u7a0b\u900f\u660e\uff0c\u5b98\u7f51\u53ef\u67e5<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- 6. \u7b7e\u7ea6\u540e\u6743\u76ca -->\n<section id=\"rhjcls08\">\n  <h3>6. \u7b7e\u7ea6\u540e\u60a8\u5c06\u62e5\u6709<\/h3>\n  <p>\u8fd9\u4e0d\u662f\u5e7f\u544a\u3002\u8fd9\u662f\u771f\u5b9e\u5ba2\u6237\u7684\u6863\u6848\u793a\u4f8b\u3002<\/p>\n  <p>\u7b7e\u7ea6\u540e\uff0c\u60a8\u4e5f\u4f1a\u62e5\u6709\u8fd9\u6837\u4e00\u4efd\u4e13\u5c5e\u6863\u6848\u2014\u2014\u4ece\u65bd\u5de5\u7167\u7247\u5230\u9a8c\u6536\u5355\u5230\u6bcf\u5e74\u8fd0\u884c\u6570\u636e\uff0c\u5168\u90e8\u516c\u5f00\u900f\u660e\uff0c\u5b98\u7f51\u53ef\u67e5\u3002<\/p>\n\n  <div class=\"info-card\">\n    <p><strong>\u6863\u6848\u5305\u542b<\/strong>\uff1a<\/p>\n    <ul style=\"padding-left:20px; margin:8px 0;\">\n      <li>\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5168\u6d41\u7a0b\u7167\u7247\u8bb0\u5f55<\/li>\n      <li>\u8bbe\u5907\u6750\u6599\u6e05\u5355<\/li>\n      <li>\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/li>\n      <li>\u6bcf\u5e74\u8fd0\u884c\u6570\u636e\uff08\u6301\u7eed\u8ddf\u8e2a10\u5e74\uff09<\/li>\n      <li>\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/li>\n    <\/ul>\n  <\/div>\n<\/section>\n\n<!-- 7. \u670d\u52a1\u627f\u8bfa -->\n<section id=\"rhjcls09\">\n  <h3>7. \u670d\u52a1\u627f\u8bfa<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u627f\u8bfa\u9879<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr>\n        <tr><td>\u6807\u51c6\u65bd\u5de5<\/td><td>\u9f99\u8109\u7cbe\u5de5\u6807\u51c6+\u6697\u57cb\u5de5\u827a\u89c4\u8303<\/td><\/tr>\n        <tr><td>\u900f\u660e\u62a5\u4ef7<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr>\n        <tr><td>\u5de5\u7a0b\u8d28\u4fdd<\/td><td>5\u5e74\u8d77\uff08\u4ee5\u5408\u540c\u6761\u6b3e\u4e3a\u51c6\uff09<\/td><\/tr>\n        <tr><td>10\u5e74\u8fd0\u884c\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u51fa\u5177\u5206\u6790\u62a5\u544a<\/td><\/tr>\n        <tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>199\u5143\/\u5e74\u4eab5-8\u6298\u670d\u52a1<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- 8. \u603b\u7ed3 -->\n<section id=\"rhjcls10\">\n  <h3>8. \u603b\u7ed3<\/h3>\n  <p><strong>\u8fd9\u5957\u65b9\u6848\u4e00\u6b21\u6027\u89e3\u51b3\u4e86\u60a8\u5173\u5fc3\u7684\u6240\u6709\u95ee\u9898\uff1a<\/strong><\/p>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u60a8\u7684\u95ee\u9898<\/th><th>\u7b54\u6848<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u6696\u6c14\u7247\u70eb\u4eba\uff1f<\/td><td>\u8868\u9762\u6e29\u5ea6\u5b89\u5168\u63a7\u5236\uff0c\u63a5\u89e6\u4e0d\u70eb\u4f24<\/td><\/tr>\n        <tr><td>\u8001\u4eba\u4e0d\u4f1a\u64cd\u4f5c\uff1f<\/td><td>\u72ec\u7acb\u7403\u9600\u63a7\u5236\uff0c\u64cd\u4f5c\u76f4\u89c2\u7b80\u5355<\/td><\/tr>\n        <tr><td>\u70ed\u503c\u4e0d\u591f\u6696\uff1f<\/td><td>C33\u52a0\u539a\u578b\u8d85\u914d\uff0c\u8001\u5e74\u4eba\"\u591a\u7ed9\u4e00\u70b9\u6e29\u6696\"<\/td><\/tr>\n        <tr><td>\u65bd\u5de5\u6270\u6c11\uff1f<\/td><td>\u6697\u57cb\u65b9\u68481-2\u5929\u5b8c\u5de5\uff0c\u4e0d\u642c\u5bb6\u5177<\/td><\/tr>\n        <tr><td>\u8001\u5ba2\u6237\u6ca1\u4fdd\u969c\uff1f<\/td><td>\u9f99\u810922\u5e74\u54c1\u724c\uff0c\u6863\u6848\u53ef\u8ffd\u6eaf\uff0c\u5b98\u7f51\u53ef\u67e5<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"highlight-box\">\n    <h4>\u8001\u5ba2\u6237\u590d\u8d2d\u4e13\u5c5e\u4f18\u60e0\uff0c\u5177\u4f53\u9762\u8bae<\/h4>\n    <p>\uff08\u542b\u66fc\u745e\u5fb7\u9505\u7089+\u6696\u6c14\u7247+\u6697\u57cb\u7ba1\u8def+\u6240\u6709\u5b89\u88c5\u8f85\u6750+5\u5e74\u8d28\u4fdd+10\u5e74\u8fd0\u884c\u8ddf\u8e2a\uff09<\/p>\n    <p><strong>\u4e0b\u4e00\u6b65<\/strong>\uff1a\u5b89\u6392\u5de5\u7a0b\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u9505\u7089\u4f4d\u7f6e\u3001\u7ba1\u8def\u8d70\u5411\u3001\u6696\u6c14\u7247\u5b89\u88c5\u4f4d\u7f6e\uff0c\u51fa\u5177\u7cbe\u786e\u5408\u540c\u4ef7\u3002<\/p>\n  <\/div>\n\n  <div class=\"info-card\">\n    <p><span class=\"label\">\u9f99\u8109\u6696\u901a\u987e\u95ee\uff1a<\/span>\u8303\u4e3d\u5982<\/p>\n    <p><span class=\"label\">\u8054\u7cfb\u7535\u8bdd\uff1a<\/span>13398198375<\/p>\n    <p><span class=\"label\">\u95e8\u5e97\u5730\u5740\uff1a<\/span>\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986\u4e09\u697cA-348<\/p>\n  <\/div>\n\n  <blockquote>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002\u671f\u5f85\u4e3a\u60a8\u6bcd\u4eb2\u4f4f\u5b85\u4ea4\u4ed8\u4e00\u5957\u6e29\u6696\u3001\u5b89\u5168\u3001\u7701\u5fc3\u7684\u6696\u6c14\u7cfb\u7edf\u3002<\/blockquote>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- \u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1 -->\n<!-- ============================================================ -->\n<div class=\"stage-header\" id=\"stage2\">\n  <span class=\"stage-label\">\u7b2c\u4e8c\u9636\u6bb5<\/span>\n  <h2>\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/h2>\n<\/div>\n\n<!-- 1. \u6982\u8ff0 -->\n<section id=\"rhjcls11\">\n  <h3>1. \u6982\u8ff0\uff1a\u4ec1\u548c\u885739\u53f7\u9662\u5e38\u8001\u5e08\u914d\u7f6e\u6750\u6599\u6e05\u5355\u53ca\u8bbe\u8ba1\u8bf4\u660e<\/h3>\n\n  <!-- 1.1 -->\n  <h4 id=\"rhjcls1101\">1.1 \u914d\u7f6e\u6750\u6599\u6e05\u5355<\/h4>\n\n  <h5>\u70ed\u6e90\u90e8\u5206\uff08\u66fc\u745e\u5fb7\uff09\u2014\u2014 \u9505\u7089<\/h5>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/td><td>L1B24-Heidelberg Min.5<\/td><td>1<\/td><td>\u53f0<\/td><td>24kW\u4e24\u7528\u7089\uff0c\u5206\u6bb5\u71c3\u70e7\uff0c\u5fb7\u7cfb\u54c1\u8d28<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h5>\u672b\u7aef\u90e8\u5206 \u2014\u2014 \u6696\u6c14\u7247<\/h5>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u5b89\u88c5\u4f4d\u7f6e<\/th><th>\u5907\u6ce8<\/th><\/thead>\n      <tbody>\n        <tr><td>\u54c1\u724c<\/td><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247<\/td><td>C33\u52a0\u539a\u578b 900\u00d71000mm<\/td><td>1<\/td><td>\u7ec4<\/td><td>\u5ba2\u5385<\/td><td>\u5ba2\u538524.2\u33a1\uff0c\u6563\u70ed\u91cf\u5145\u8db3\uff0c\u9002\u8001\u5316\u914d\u7f6e<\/td><\/tr>\n        <tr><td>\u54c1\u724c<\/td><td>\u94a2\u5236\u67f1\u5f0f\u6696\u6c14\u7247<\/td><td>C22 300\u00d71400mm<\/td><td>1<\/td><td>\u7ec4<\/td><td>\u5367\u5ba4<\/td><td>\u5367\u5ba429.4\u33a1\uff08\u542b\u9633\u53f0\uff09\uff0c\u4f4e\u77ee\u578b\u6cbf\u7a97\u53f0\u4e0b\u5b89\u88c5<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h5>\u7ba1\u8def\u53ca\u8f85\u6750\u90e8\u5206<\/h5>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u529f\u80fd<\/th><th>\u5907\u6ce8<\/th><\/thead>\n      <tbody>\n        <tr><td>\u54c1\u724c<\/td><td>PPR\u70ed\u6c34\u7ba1<\/td><td>\u8010\u9ad8\u6e29PPR\u7ba1<\/td><td>\u6309\u9700<\/td><td>m<\/td><td>\u6697\u57cb\u70ed\u6c34\u8f93\u9001<\/td><td>\u8010\u9ad8\u6e29\u3001\u6297\u8001\u5316<\/td><\/tr>\n        <tr><td>\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u5957\u7ba1<\/td><td>\u00d825\/\u00d820<\/td><td>\u6309\u9700<\/td><td>m<\/td><td>\u7ba1\u9053\u4fdd\u6e29\uff0c\u51cf\u5c11\u70ed\u635f\u5931<\/td><td>\u534e\u7f8e\u54c1\u724c\uff0c\u4fdd\u6e29\u6027\u80fd\u597d<\/td><\/tr>\n        <tr><td>\u54c1\u724c<\/td><td>\u9ec4\u94dc\u7403\u9600<\/td><td>DN15<\/td><td>2<\/td><td>\u4e2a<\/td><td>\u6bcf\u7ec4\u6696\u6c14\u7247\u72ec\u7acb\u901a\u65ad<\/td><td>\u6253\u5f00\/\u5173\u95ed\u4e92\u4e0d\u5f71\u54cd<\/td><\/tr>\n        <tr><td>\u54c1\u724c<\/td><td>\u624b\u52a8\u6e29\u63a7\u9600<\/td><td>DN15<\/td><td>2<\/td><td>\u4e2a<\/td><td>\u8c03\u8282\u70ed\u6c34\u6d41\u91cf\uff0c\u63a7\u5236\u5ba4\u6e29<\/td><td>\u624b\u52a8\u64cd\u4f5c\uff0c\u7b80\u5355\u53ef\u9760<\/td><\/tr>\n        <tr><td>\u54c1\u724c<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u5f2f\u5934\u3001\u4e09\u901a\u7b49<\/td><td>1<\/td><td>\u9879<\/td><td>\u8fde\u63a5\u7ba1\u9053<\/td><td>\u5f02\u7a0b\u8fde\u63a5\u4e13\u7528<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 1.2 -->\n  <h4 id=\"rhjcls1102\">1.2 \u8bbe\u8ba1\u4f9d\u636e<\/h4>\n  <ul style=\"padding-left:20px; margin:12px 0;\">\n    <li>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB50736-2012<\/li>\n    <li>\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142-2012<\/li>\n    <li>\u300a\u91c7\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB50019-2015<\/li>\n    <li>\u597d\u7cfb\u7edf\u56db\u8981\u7d20\uff1a\u70ed\u6e90+\u8f93\u914d+\u672b\u7aef+\u63a7\u5236<\/li>\n    <li>\u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/li>\n  <\/ul>\n  <p><strong>\u8bbe\u8ba1\u53c2\u6570<\/strong>\uff1a\u51ac\u5b63\u8bbe\u8ba1\u5ba4\u6e29 18~22\u2103\uff1b\u6696\u6c14\u7247\u4f9b\u6c34\u6e29\u5ea6 70~80\u2103\uff08\u5e38\u89c4\uff09\/ 50~60\u2103\uff08\u4f4e\u6e29\u578b\uff09\uff1b\u5f02\u7a0b\u8fde\u63a5\u6d41\u901f\u22650.25m\/s\uff1b\u4fdd\u6e29\u540e\u7ba1\u8def\u70ed\u635f\u5931&lt;5%\u3002<\/p>\n  <p><strong>\u9002\u8001\u5316\u8bbe\u8ba1\u8981\u70b9<\/strong>\uff1a\u70ed\u503c\u8d85\u914d\uff08\u786e\u4fdd\u6696\u548c\uff09\uff1b\u64cd\u4f5c\u7b80\u5355\uff08\u72ec\u7acb\u7403\u9600\uff0c\u65e0\u9700\u5b66\u4e60\uff09\uff1b\u5b89\u5168\u63a7\u5236\uff08\u8868\u9762\u6e29\u5ea6\u4e0d\u70eb\u4f24\uff09\uff1b\u65bd\u5de5\u4e0d\u6270\u6c11\uff081-2\u5929\u5b8c\u5de5\uff09\u3002<\/p>\n\n  <!-- 1.3 -->\n  <h4 id=\"rhjcls1103\">1.3 \u5907\u6ce8\u8bf4\u660e<\/h4>\n  <ul style=\"padding-left:20px; margin:12px 0;\">\n    <li>\u672c\u65b9\u6848\u542b\u9505\u7089\u3001\u6696\u6c14\u7247\u3001\u7ba1\u8def\u53ca\u6240\u6709\u8f85\u6750\uff0c\u5305\u5de5\u5305\u6599\uff1b<\/li>\n    <li>\u6697\u57cb\u7ba1\u8def\u65bd\u5de5\u524d\u9700\u786e\u8ba4\u5899\u9762\/\u5730\u9762\u5f00\u69fd\u4f4d\u7f6e\uff0c\u7ecf\u5ba2\u6237\u540c\u610f\u540e\u65b9\u53ef\u65bd\u5de5\uff1b<\/li>\n    <li>\u4fdd\u6e29\u5957\u7ba1\u5168\u7a0b\u8986\u76d6\uff0c\u51cf\u5c11\u70ed\u635f\u5931\uff1b<\/li>\n    <li>\u5f02\u7a0b\u8fde\u63a5\u65e0\u9700\u5206\u96c6\u6c34\u5668\uff0c\u7ba1\u8def\u7b80\u6d01\uff0c\u6210\u672c\u66f4\u4f18\uff1b<\/li>\n    <li>\u6240\u6709\u62a5\u4ef7\u4ec5\u4f9b\u53c2\u8003\uff0c\u6700\u7ec8\u4ee5\u5408\u540c\u7b7e\u5b57\u76d6\u7ae0\u4e3a\u51c6\uff1b<\/li>\n    <li>\u8001\u5ba2\u6237\u590d\u8d2d\uff0c\u4eab\u53d7\u4e13\u5c5e\u4f18\u60e0\uff0c\u5177\u4f53\u9762\u8bae\u3002<\/li>\n  <\/ul>\n<\/section>\n\n<!-- 2. \u65bd\u5de5\u6d41\u7a0b -->\n<section id=\"rhjcls12\">\n  <h3>2. \u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de56\u6b65\u6cd5+2<\/h3>\n\n  <h4 id=\"rhjcls1201\">2.1 \u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/h4>\n  <p>\u4ee5\u4e0b\u4e3a\u4ec1\u548c\u885739\u53f7\u966212-1-506\u53f7\u73b0\u573a\u52d8\u6d4b\u5b9e\u62cd\uff0c\u6db5\u76d6\u9505\u7089\u5b89\u88c5\u4f4d\u3001\u6696\u6c14\u7247\u9884\u7559\u4f4d\u3001\u7ba1\u8def\u8d70\u5411\u7b49\u5173\u952e\u8282\u70b9\u3002<\/p>\n  <div class=\"survey-gallery\">\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG01.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724701\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 01<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG02.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724702\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 02<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG03.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724703\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 03<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG04.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724704\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 04<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG05.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724705\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 05<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG06.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724706\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 06<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG07.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724707\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 07<\/figcaption>\n    <\/figure>\n    <figure>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG08.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u7167\u724708\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u7167\u7247 08<\/figcaption>\n    <\/figure>\n  <\/div>\n\n  <h4 id=\"rhjcls1202\">2.2 \u7b2c\u4e8c\u6b65\uff1a\u8bbe\u8ba1\u51fa\u56fe<\/h4>\n  <ul style=\"padding-left:20px; margin:8px 0;\">\n    <li>\u6696\u6c14\u7247\u5e03\u7f6e\u56fe\uff08\u6807\u6ce8\u5b89\u88c5\u4f4d\u7f6e\u3001\u89c4\u683c\uff09<\/li>\n    <li>\u6697\u57cb\u7ba1\u8def\u8d70\u5411\u56fe\uff08\u5f00\u69fd\u4f4d\u7f6e\u3001\u5f02\u7a0b\u8fde\u63a5\u8def\u5f84\uff09<\/li>\n    <li>\u9505\u7089\u5b89\u88c5\u5b9a\u4f4d\u56fe<\/li>\n  <\/ul>\n\n  <h4 id=\"rhjcls1203\">2.3 \u7b2c\u4e09\u6b65\uff1a\u9690\u853d\u5de5\u7a0b\u7cbe\u5de56\u6b65\u6cd5<\/h4>\n  <p>\u5b9a\u4f4d \u2192 \u6e05\u5355\u9a8c\u6536 \u2192 \u6309\u56fe\u65bd\u5de5 \u2192 \u6807\u51c6\u5de5\u827a \u2192 \u76d1\u7406 \u2192 \u4e09\u65b9\u9a8c\u6536<\/p>\n  <ul style=\"padding-left:20px; margin:8px 0;\">\n    <li>\u6309\u56fe\u65bd\u5de5\u3001\u6697\u57cb\u7ba1\u8def\u5f00\u69fd\u3001PPR\u70ed\u7194\u8fde\u63a5<\/li>\n    <li>\u4fdd\u6e29\u5957\u7ba1\u5168\u7a0b\u8986\u76d6\u3001\u5f02\u7a0b\u8fde\u63a5\u7ba1\u8def\u5e73\u8861<\/li>\n    <li>\u9505\u7089\u5b89\u88c5\u3001\u70df\u9053\u5b89\u88c5\u3001\u6c34\u8def\u8fde\u63a5<\/li>\n    <li>\u6696\u6c14\u7247\u6302\u88c5\u3001\u9600\u95e8\u5b89\u88c5<\/li>\n  <\/ul>\n\n  <h4 id=\"rhjcls1204\">2.4 \u7b2c\u56db\u6b65\uff1a\u76d1\u7406\u5230\u4f4d<\/h4>\n  <p>\u4e13\u4e1a\u76d1\u7406\u4eba\u5458\u5168\u7a0b\u8ddf\u8e2a\u65bd\u5de5\u8d28\u91cf\uff0c\u91cd\u70b9\u5173\u6ce8\u6697\u57cb\u7ba1\u8def\u70ed\u7194\u8d28\u91cf\u3001\u4fdd\u6e29\u5957\u7ba1\u8986\u76d6\u3001\u5f02\u7a0b\u8fde\u63a5\u5e73\u8861\u3002<\/p>\n\n  <h4 id=\"rhjcls1205\">2.5 \u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/h4>\n  <p>\u9505\u7089\u70b9\u706b\u6d4b\u8bd5\u3001\u6696\u6c14\u7247\u5347\u6e29\u6d4b\u8bd5\u3001\u9600\u95e8\u63a7\u5236\u6d4b\u8bd5\u3001\u5f02\u7a0b\u8fde\u63a5\u70ed\u5e73\u8861\u6d4b\u8bd5\u3002<\/p>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u8c03\u8bd5\u9879\u76ee<\/th><th>\u6807\u51c6<\/th><th>\u7ed3\u679c<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u9505\u7089\u70b9\u706b<\/td><td>\u6b63\u5e38\u70b9\u706b\uff0c\u65e0\u6545\u969c\u4ee3\u7801<\/td><td class=\"empty-data\">\u23f3 \u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u5ba2\u5385\u6696\u6c14\u7247\u5347\u6e29<\/td><td>30\u5206\u949f\u5185\u8868\u9762\u6e29\u5ea6\u226550\u2103<\/td><td class=\"empty-data\">\u23f3 \u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u5367\u5ba4\u6696\u6c14\u7247\u5347\u6e29<\/td><td>30\u5206\u949f\u5185\u8868\u9762\u6e29\u5ea6\u226550\u2103<\/td><td class=\"empty-data\">\u23f3 \u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u5f02\u7a0b\u8fde\u63a5\u5e73\u8861<\/td><td>\u4e24\u7ec4\u6696\u6c14\u7247\u70ed\u6548\u679c\u4e00\u81f4\uff0c\u65e0\u660e\u663e\u6e29\u5dee<\/td><td class=\"empty-data\">\u23f3 \u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u9600\u95e8\u63a7\u5236<\/td><td>\u72ec\u7acb\u7403\u9600\u5f00\/\u5173\u6b63\u5e38\uff0c\u4e92\u4e0d\u5f71\u54cd<\/td><td class=\"empty-data\">\u23f3 \u5f85\u586b\u5199<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h4 id=\"rhjcls1206\">2.6 \u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u9a8c\u6536\u65e5\u671f<\/td><td class=\"empty-data\">\u5e74 \u6708 \u65e5<\/td><\/tr>\n        <tr><td>\u9a8c\u6536\u4eba\u5458<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u9a8c\u6536\u5185\u5bb9<\/td><td>\u5168\u7cfb\u7edf\u8fd0\u884c \/ \u6696\u6c14\u7247\u5347\u6e29\u6548\u679c \/ \u9600\u95e8\u63a7\u5236\u786e\u8ba4 \/ \u64cd\u4f5c\u6559\u5b66\u6f14\u793a<\/td><\/tr>\n        <tr><td>\u9a8c\u6536\u7ed3\u8bba<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- +1 \u4ea4\u4ed8\u6559\u5b66 -->\n  <h4 id=\"rhjcls1207\">2.7 +1\uff1a\u4ea4\u4ed8\u6559\u5b66\uff08\u542b\u64cd\u4f5c\u8981\u70b9\u901f\u67e5\uff09<\/h4>\n\n  <h5>\u4e00\u3001\u9505\u7089\u90e8\u5206\uff08\u66fc\u745e\u5fb7 L1B24\uff09<\/h5>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u64cd\u4f5c\u8981\u70b9<\/th><th>\u8bbe\u5b9a\/\u64cd\u4f5c\u65b9\u5f0f<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td><strong>\u91c7\u6696\u6c34\u6e29\u8bbe\u7f6e<\/strong><\/td><td><strong>50-70\u2103<\/strong>\uff08\u6696\u6c14\u7247\u5e38\u89c4\u8fd0\u884c\uff0c\u4e0d\u8d85\u8fc780\u2103\uff09<\/td><\/tr>\n        <tr><td>\u5ba4\u6e29\u8bbe\u7f6e<\/td><td>\u901a\u8fc7\u624b\u52a8\u6e29\u63a7\u9600\u8c03\u8282\uff0c\u5efa\u8bae <strong>18-22\u2103<\/strong><\/td><\/tr>\n        <tr><td>\u51ac\u5b63\u6a21\u5f0f<\/td><td>\u9505\u7089\u8bbe\u5b9a\u4e3a\"\u51ac\u5b63\u6a21\u5f0f\"\uff0c\u540c\u65f6\u63d0\u4f9b\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34<\/td><\/tr>\n        <tr><td>\u590f\u5b63\u6a21\u5f0f<\/td><td>\u4ec5\u63d0\u4f9b\u751f\u6d3b\u70ed\u6c34\uff0c\u5173\u95ed\u91c7\u6696\u529f\u80fd<\/td><\/tr>\n        <tr><td>\u5916\u51fa\u6a21\u5f0f<\/td><td>\u77ed\u671f\u79bb\u5bb6\u53ef\u9002\u5f53\u8c03\u4f4e\u6c34\u6e29\uff0c<strong>\u4e0d\u8981\u5b8c\u5168\u5173\u95ed<\/strong>\uff08\u9632\u51bb\uff09<\/td><\/tr>\n        <tr><td>\u957f\u671f\u79bb\u5bb6<\/td><td>\u4fdd\u6301\u9505\u7089\u901a\u7535\u901a\u6c14\uff0c\u542f\u7528\u9632\u51bb\u6a21\u5f0f\uff08\u6e29\u5ea6&lt;5\u2103\u81ea\u52a8\u542f\u52a8\uff09<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u8865\u6c34<\/td><td>\u6c34\u538b\u4f4e\u4e8e<strong>1.0bar<\/strong>\u65f6\u6253\u5f00\u8865\u6c34\u9600\uff0c\u8865\u6c34\u81f3<strong>1.2-1.5bar<\/strong>\u540e\u5173\u95ed<\/td><\/tr>\n        <tr><td>\u6392\u6c14\u64cd\u4f5c<\/td><td>\u91c7\u6696\u5b63\u5f00\u59cb\u524d\uff0c\u5bf9\u6696\u6c14\u7247\u8fdb\u884c\u6392\u6c14\uff08\u7528\u6392\u6c14\u9600\u87ba\u4e1d\u5200\uff09<\/td><\/tr>\n        <tr><td>\u9505\u7089\u4fdd\u517b<\/td><td>1-2\u5e74\u6e05\u6d17\u71c3\u70e7\u5ba4\u3001\u98ce\u673a\u53f6\u8f6e<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h5>\u4e8c\u3001\u6696\u6c14\u7247\u90e8\u5206\uff08\u5355\u72ec\u9600\u95e8\u63a7\u5236\uff09<\/h5>\n  <div class=\"valve-grid\">\n    <div class=\"valve-card\">\n      <div class=\"icon\">\ud83d\udd35<\/div>\n      <h5>\u5404\u7ec4\u72ec\u7acb\u7403\u9600<\/h5>\n      <p>\u5ba2\u5385C33\u4e0e\u5367\u5ba4C22\u5404\u5b89\u88c5\u72ec\u7acb\u9ec4\u94dc\u7403\u9600\uff0c\u6253\u5f00\/\u5173\u95ed\u4e92\u4e0d\u5f71\u54cd\u3002\u9700\u8981\u54ea\u4e2a\u623f\u95f4\u6696\u548c\uff0c\u5c31\u5f00\u54ea\u4e2a\u9600\u2014\u2014\u64cd\u4f5c\u76f4\u89c2\uff0c\u8001\u5e74\u4eba\u4e5f\u80fd\u8f7b\u677e\u638c\u63a7\u3002<\/p>\n    <\/div>\n    <div class=\"valve-card\">\n      <div class=\"icon\">\ud83c\udf21\ufe0f<\/div>\n      <h5>\u6e29\u63a7\u9600\u624b\u52a8\u8c03\u6e29<\/h5>\n      <p>\u6bcf\u7ec4\u6696\u6c14\u7247\u642d\u914d\u624b\u52a8\u6e29\u63a7\u9600\uff0c\u53ef\u5206\u522b\u8c03\u8282\u70ed\u6c34\u6d41\u91cf\uff0c\u5b9e\u73b0\u5ba2\u5385\u4e0e\u5367\u5ba4\u6e29\u5ea6\u5dee\u5f02\u5316\u8c03\u8282\u2014\u2014\u8001\u5e74\u4eba\u5e38\u5f85\u5ba2\u5385\u5f00\u5927\uff0c\u5367\u5ba4\u7761\u7720\u65f6\u8c03\u5c0f\uff0c\u7701\u6c14\u53c8\u8212\u9002\u3002<\/p>\n    <\/div>\n    <div class=\"valve-card\">\n      <div class=\"icon\">\ud83d\udee0\ufe0f<\/div>\n      <h5>\u7cfb\u7edf\u7b80\u6d01\u53ef\u9760<\/h5>\n      <p>\u65e0\u9700\u989d\u5916\u63a7\u5236\u6a21\u5757\uff0c\u7ba1\u8def\u4e0e\u9600\u95e8\u76f4\u63a5\u63a7\u5236\uff0c\u6545\u969c\u70b9\u5c11\u3001\u7ef4\u62a4\u7b80\u5355\u3002\u65e0\u7535\u5b50\u8bbe\u5907\u4f9d\u8d56\uff0c\u4e0d\u53d7\u505c\u7535\u3001\u4fe1\u53f7\u5f71\u54cd\uff0c\u7ecf\u4e45\u8010\u7528\uff0c\u7279\u522b\u9002\u5408\u8001\u5e74\u4eba\u5bb6\u5ead\u4f7f\u7528\u3002<\/p>\n    <\/div>\n    <div class=\"valve-card\">\n      <div class=\"icon\">\ud83d\udca1<\/div>\n      <h5>\u4f7f\u7528\u65b9\u5f0f\u8bf4\u660e<\/h5>\n      <p>\u9505\u7089\u6b63\u5e38\u8fd0\u884c\u65f6\uff0c\u6253\u5f00\u5bf9\u5e94\u6696\u6c14\u7247\u7403\u9600\u5373\u53ef\u4f9b\u6696\uff1b\u5355\u72ec\u5173\u95ed\u67d0\u7ec4\u4e0d\u5f71\u54cd\u53e6\u4e00\u7ec4\u4f9b\u6696\u3002\u5916\u51fa\u8f83\u957f\u65f6\u95f4\u53ef\u624b\u52a8\u5173\u95ed\u5168\u90e8\u9600\u95e8\uff0c\u56de\u6765\u524d\u518d\u6253\u5f00\uff0c\u7b80\u5355\u65b9\u4fbf\u3002<\/p>\n    <\/div>\n  <\/div>\n\n  <h5>\u4e09\u3001\u901a\u7528\u7ef4\u62a4\u63d0\u9192<\/h5>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u9879\u76ee<\/th><th>\u5468\u671f<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u6696\u6c14\u7247\u6392\u6c14<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u5f00\u59cb\u524d<\/td><td>\u81ea\u884c\u64cd\u4f5c\uff0c\u7528\u6392\u6c14\u9600\u87ba\u4e1d\u5200<\/td><\/tr>\n        <tr><td>\u9505\u7089\u8865\u6c34<\/td><td>\u6c34\u538b\u4f4e\u4e8e1.0bar\u65f6<\/td><td>\u81ea\u884c\u64cd\u4f5c\uff0c\u8865\u6c34\u81f31.2-1.5bar<\/td><\/tr>\n        <tr><td>\u9505\u7089\u4fdd\u517b<\/td><td>1-2\u5e74<\/td><td>\u4e13\u4e1a\u552e\u540e\u4e0a\u95e8<\/td><\/tr>\n        <tr><td>\u7ba1\u8def\u68c0\u67e5<\/td><td>\u6bcf\u5e74<\/td><td>\u68c0\u67e5\u4fdd\u6e29\u5957\u7ba1\u662f\u5426\u5b8c\u597d<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u5e74\u5ea6\u68c0\u6d4b<\/td><td>\u6bcf\u5e74<\/td><td>\u4f1a\u5458\u670d\u52a1\u5305\u542b<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h5>\u56db\u3001\u7d27\u6025\u60c5\u51b5\u5904\u7406<\/h5>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u95ee\u9898<\/th><th>\u5904\u7406\u65b9\u5f0f<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u9505\u7089\u62a5\u6545\u969c\u4ee3\u7801<\/td><td>\u8bb0\u5f55\u4ee3\u7801\uff0c\u8054\u7cfb\u552e\u540e\uff0813398198375\uff09<\/td><\/tr>\n        <tr><td>\u6696\u6c14\u7247\u4e0d\u70ed<\/td><td>\u68c0\u67e5\u7403\u9600\u662f\u5426\u6253\u5f00\uff1b\u6392\u6c14\uff1b\u8054\u7cfb\u552e\u540e<\/td><\/tr>\n        <tr><td>\u67d0\u7ec4\u6696\u6c14\u7247\u4e0d\u70ed\uff08\u5f02\u7a0b\uff09<\/td><td>\u68c0\u67e5\u9600\u95e8\uff1b\u6392\u6c14\uff1b\u8054\u7cfb\u552e\u540e\u8c03\u6574\u6d41\u91cf<\/td><\/tr>\n        <tr><td>\u9505\u7089\u6c34\u538b\u8fc7\u4f4e<\/td><td>\u6253\u5f00\u8865\u6c34\u9600\uff0c\u8865\u6c34\u81f31.2-1.5bar<\/td><\/tr>\n        <tr><td>\u957f\u671f\u79bb\u5bb6\u540e\u7cfb\u7edf\u51bb\u574f<\/td><td>\u4fdd\u6301\u9505\u7089\u901a\u7535\u901a\u6c14\uff0c\u542f\u7528\u9632\u51bb\u6a21\u5f0f<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- +2 \u552e\u540e\u4fdd\u969c -->\n  <h4 id=\"rhjcls1208\">2.8 +2\uff1a\u552e\u540e\u4fdd\u969c\uff08\u542b\u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355\uff09<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u4fdd\u969c\u9879<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8bbe\u5907\u8d28\u4fdd<\/td><td>\u66fc\u745e\u5fb7\u5382\u5bb6\u8d28\u4fdd\uff08\u4ee5\u5382\u5bb6\u653f\u7b56\u4e3a\u51c6\uff09<\/td><\/tr>\n        <tr><td>\u5de5\u7a0b\u8d28\u4fdd<\/td><td>5\u5e74\u8d77\uff08\u4ee5\u5408\u540c\u6761\u6b3e\u4e3a\u51c6\uff09<\/td><\/tr>\n        <tr><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd\uff08\u5982\u9002\u7528\uff09<\/td><\/tr>\n        <tr><td>\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b\/\u7ef4\u4fdd\u63d0\u9192\/\u4f18\u5148\u54cd\u5e94\/\u670d\u52a1\u6298\u6263\/\u8fdc\u7a0b\u8bca\u65ad<\/td><\/tr>\n        <tr><td>\u7d27\u6025\u62a5\u4fee<\/td><td>\u9f99\u8109\u6696\u901a\u552e\u540e\u7535\u8bdd\uff1a13398198375<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- \u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3 -->\n<!-- ============================================================ -->\n<div class=\"stage-header\" id=\"stage3\">\n  <span class=\"stage-label\">\u7b2c\u4e09\u9636\u6bb5<\/span>\n  <h2>\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3<\/h2>\n<\/div>\n\n<!-- 1. \u5ba2\u6237\u53cd\u9988 -->\n<section id=\"rhjcls13\">\n  <h3>1. \u5ba2\u6237\u53cd\u9988<\/h3>\n  <div class=\"info-card\">\n    <p><strong>\ud83d\udcdd \u53cd\u9988\u8bb0\u5f55<\/strong><\/p>\n    <p>\u5e38\u8001\u5e08\u539f\u8bdd\uff1a\"\u6211\u5bb6\u6696\u6c14\u7247\u662f\u4f60\u5b89\u7684\uff0c\u6211\u5988\u5bb6\u4e5f\u8981\u3002\"\u2014\u2014\u4fe1\u4efb\u662f\u6700\u597d\u7684\u9500\u552e\u3002<\/p>\n    <p>\u6bcd\u4eb2\u53cd\u9988\uff1a<span class=\"empty-data\">\u23f3 \u5f85\u91c7\u6696\u5b63\u4f7f\u7528\u540e\u91c7\u96c6<\/span><\/p>\n  <\/div>\n  <blockquote>\n    \u8001\u5ba2\u6237\u4fe1\u8d56\u590d\u8d2d\uff0c\u662f\u5bf9\u9f99\u8109\u6696\u901a\u6700\u5927\u7684\u8ba4\u53ef\u3002\u6211\u4eec\u5c06\u4e3a\u5e38\u8001\u5e08\u6bcd\u4eb2\u4f4f\u5b85\u4ea4\u4ed8\u4e00\u5957\u540c\u6837\u9ad8\u54c1\u8d28\u7684\u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf\uff0c\u8ba9\u4e24\u4f4d\u8001\u4eba\u6e29\u6696\u8fc7\u51ac\u3002\n  <\/blockquote>\n<\/section>\n\n<!-- 2. \u8fd0\u884c\u8bb0\u5f55 -->\n<section id=\"rhjcls14\">\n  <h3>2. \u8fd0\u884c\u8bb0\u5f55\u4e0e\u89e3\u6790 <span class=\"badge badge-primary\">\u5f85\u5e74\u5ea6\u6570\u636e\u5f55\u5165<\/span><\/h3>\n\n  <h4 id=\"rhjcls1401\">2.1 \u8fd0\u884c\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa<\/h4>\n  <p>\u6211\u4eec\u5173\u6ce8\u60a8\u672a\u676520\u5e74\u7684\u4f7f\u7528\u8212\u9002\u3001\u7a33\u5b9a\u548c\u8282\u80fd\u3002\u4e3a\u6b64\uff0c\u6211\u4eec\u627f\u8bfa\uff1a<\/p>\n\n  <div class=\"commitment-card\">\n    <h5>1\u3001\u6bcf\u5e74\u8fd0\u884c\u5206\u6790\u4e0e\u4f18\u5316\u5efa\u8bae<\/h5>\n    <p>\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\uff0c\u4e3a\u60a8\u63d0\u4f9b\u4e00\u4efd\u8fd0\u884c\u5206\u6790\u62a5\u544a\uff0c\u5305\u542b\uff1a\u5f53\u5e74\u5b9e\u9645\u7528\u6c14\u91cf\u53ca\u8d39\u7528\u3001\u540c\u6237\u578b\u540c\u914d\u7f6e\u5bf9\u6807\u6570\u636e\u3001\u8282\u80fd\u4f18\u5316\u5efa\u8bae\u3002\u5982\u7cfb\u7edf\u8fd0\u884c\u8d39\u7528\u663e\u8457\u9ad8\u4e8e\u5408\u7406\u8303\u56f4\uff0c\u6211\u4eec\u4e3b\u52a8\u4e0a\u95e8\u6392\u67e5\u539f\u56e0\u3002<\/p>\n  <\/div>\n\n  <div class=\"commitment-card\">\n    <h5>2\u3001\u514d\u8d39\u4f18\u5316\u65b9\u6848<\/h5>\n    <p>\u5982\u6392\u67e5\u53d1\u73b0\u7cfb\u7edf\u5b58\u5728\u53ef\u4f18\u5316\u7684\u73af\u8282\uff08\u5982\u7ba1\u8def\u6c34\u529b\u5e73\u8861\u5fae\u8c03\u3001\u9600\u95e8\u8c03\u8282\u3001\u8bbe\u5907\u53c2\u6570\u8c03\u6574\uff09\uff0c\u6211\u4eec\u514d\u8d39\u63d0\u4f9b\u4f18\u5316\u65b9\u6848\u5e76\u534f\u52a9\u5b9e\u65bd\u3002<\/p>\n  <\/div>\n\n  <div class=\"commitment-card\">\n    <h5>3\u300110\u5e74\u8ddf\u8e2a\u627f\u8bfa<\/h5>\n    <p>\u4ee5\u672c\u6863\u6848\u7b7e\u7f72\u65e5\u671f\u4e3a\u8d77\u70b9\uff0c\u6211\u4eec\u63d0\u4f9b<strong>10\u5e74\u8fd0\u884c\u8ddf\u8e2a\u670d\u52a1<\/strong>\u3002PPR\u7ba1\u9053\u7cfb\u7edf\u8bbe\u8ba1\u5bff\u547d20\u5e74\u4ee5\u4e0a\u3002\u9505\u7089\u4e3a\u56fd\u5bb6\u5f3a\u5236\u6027\u62a5\u5e9f\u8bbe\u5907\uff08\u62a5\u5e9f\u671f8\u5e74\uff09\uff0c\u6211\u4eec\u5c06\u5728\u7b2c9\u5e74\u4e3b\u52a8\u63d0\u9192\u60a8\u66f4\u6362\u8bbe\u5907\uff0c\u66f4\u6362\u540e\u8fd0\u884c\u8ddf\u8e2a\u670d\u52a1\u81ea\u52a8\u5ef6\u7eed\u3002<\/p>\n  <\/div>\n\n  <blockquote>\u5e38\u8001\u5e08\uff0c\u60a8\u5df2\u52a0\u5165\u9f99\u8109\u6696\u901a\"\u6696\u6c14\u7247\u6d4b\u8bc4\u5b98\"\u8ba1\u5212\u3002\u6211\u4eec\u5c06\u5bf9\u60a8\u5bb6\u6696\u6c14\u7247\u7cfb\u7edf\u8fdb\u884c10\u5e74\u8fd0\u884c\u8ddf\u8e2a\uff0c\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\u51fa\u5177\u4e00\u4efd\u8fd0\u884c\u5206\u6790\u62a5\u544a\u3002\u8fd9\u4efd\u6863\u6848\u662f\u8ddf\u8e2a\u7684\u6570\u636e\u57fa\u51c6\u3002<\/blockquote>\n\n  <!-- 2.2 -->\n  <h4 id=\"rhjcls1402\">2.2 \u6570\u636e\u57fa\u51c6\uff08\u8c03\u8bd5\u5f53\u65e5\u8bb0\u5f55\uff09<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u9879\u76ee<\/th><th>\u57fa\u51c6\u6570\u636e<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8c03\u8bd5\u65e5\u671f<\/td><td class=\"empty-data\">\u5e74 \u6708 \u65e5<\/td><\/tr>\n        <tr><td>\u9505\u7089\u4f9b\u6c34\u6e29\u5ea6<\/td><td class=\"empty-data\">\u5f85\u586b\u5199 \u2103<\/td><\/tr>\n        <tr><td>\u5ba2\u5385\u6696\u6c14\u7247\u8868\u9762\u6e29\u5ea6<\/td><td class=\"empty-data\">\u5f85\u586b\u5199 \u2103<\/td><\/tr>\n        <tr><td>\u5367\u5ba4\u6696\u6c14\u7247\u8868\u9762\u6e29\u5ea6<\/td><td class=\"empty-data\">\u5f85\u586b\u5199 \u2103<\/td><\/tr>\n        <tr><td>\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6<\/td><td>20 \u2103\uff08\u5efa\u8bae\uff09<\/td><\/tr>\n        <tr><td>\u5ba4\u5916\u6e29\u5ea6<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u71c3\u6c14\u8868\u521d\u59cb\u8bfb\u6570<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td>\u9505\u7089\u578b\u53f7<\/td><td>\u66fc\u745e\u5fb7 L1B24-Heidelberg Min.5<\/td><\/tr>\n        <tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>33.6\u33a1<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 2.3 -->\n  <h4 id=\"rhjcls1403\">2.3 \u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u5e74\u5ea6<\/th><th>\u91c7\u6696\u5b63(\u6708)<\/th><th>\u603b\u7528\u6c14\u91cf(m\u00b3)<\/th><th>\u603b\u8d39\u7528(\u5143)<\/th><th>\u6708\u5747\u8d39\u7528(\u5143)<\/th><th>\u5355\u4f4d\u8d39\u7528(\u5143\/\u33a1\u00b7\u6708)<\/th><th>\u4e1a\u4e3b\u53cd\u9988<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u7b2c1\u5e74<\/td><td class=\"empty-data\">2026\u5e74<\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><\/tr>\n        <tr><td>\u7b2c2\u5e74<\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><\/tr>\n        <tr><td>\u7b2c3\u5e74<\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><\/tr>\n        <tr><td>\u7b2c4\u5e74<\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><\/tr>\n        <tr><td>\u7b2c5\u5e74<\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><td class=\"empty-data\"><\/td><\/tr>\n        <tr><td colspan=\"7\" style=\"text-align:center; color:#95a5a6; font-style:italic;\">\u2026\u2026 \u8ddf\u8e2a\u81f3\u7b2c10\u5e74 \u2026\u2026<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 2.4 -->\n  <h4 id=\"rhjcls1404\">2.4 \u8fd0\u884c\u5bf9\u6807\u57fa\u51c6<\/h4>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u5bf9\u6807\u9879<\/th><th>\u5408\u7406\u8303\u56f4<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>33.6\u33a1\u6696\u6c14\u7247\u7cfb\u7edf\u91c7\u6696\u5b63\u8d39\u7528<\/td><td>\u7ea6 800-1500\u5143\/\u6708<\/td><td>\u4ee5\u6210\u90fd\u6c14\u4ef7\u7ea62.5\u5143\/m\u00b3\u4f30\u7b97\uff0c\u5b9e\u9645\u4ee5\u71c3\u6c14\u8d26\u5355\u4e3a\u51c6<\/td><\/tr>\n        <tr><td>\u9505\u7089\u70ed\u6548\u7387<\/td><td>\u226590%<\/td><td>\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\uff0c\u70ed\u6548\u7387\u4f18\u5f02<\/td><\/tr>\n        <tr><td>\u6696\u6c14\u7247\u8868\u9762\u6e29\u5ea6<\/td><td>50-70\u2103<\/td><td>\u4f9b\u6c34\u6e29\u5ea670-80\u2103\u65f6\uff0c\u8868\u9762\u6e29\u5ea6\u8fbe\u6807<\/td><\/tr>\n        <tr><td>\u5ba4\u6e29\u8fbe\u6807\u65f6\u95f4<\/td><td>\u9505\u7089\u542f\u52a8\u540e30\u5206\u949f\u5185<\/td><td>\u6696\u6c14\u7247\u5347\u6e29\u5feb\uff0c\u4f18\u4e8e\u5730\u6696<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- 3. \u552e\u540e\u670d\u52a1\u8bb0\u5f55 -->\n<section id=\"rhjcls15\">\n  <h3>3. \u552e\u540e\u670d\u52a1\u8bb0\u5f55\u4e0e\u89e3\u6790<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u65e5\u671f<\/th><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u670d\u52a1\u5185\u5bb9<\/th><th>\u5de5\u7a0b\u5e08<\/th><th>\u5ba2\u6237\u786e\u8ba4<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><td class=\"empty-data\">\u5f85\u586b\u5199<\/td><\/tr>\n        <tr><td colspan=\"5\" style=\"text-align:center; color:#95a5a6; font-style:italic;\">\u670d\u52a1\u8bb0\u5f55\u5c06\u6301\u7eed\u66f4\u65b0\u2026\u2026<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<\/div><!-- \/container -->\n\n<!-- ============ FOOTER ============ -->\n<footer>\n  <p><strong>\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u4e13\u6ce8\u53ef\u89c6\u5316\u670d\u52a1<\/strong><\/p>\n  <p>\u8ba9\u6bcf\u4e00\u6b21\u670d\u52a1\u90fd\u7ecf\u5f97\u8d77\u8ffd\u6eaf \u00b7 \u8ba9\u6bcf\u4e00\u4f4d\u5ba2\u6237\u90fd\u62e5\u6709\u4e13\u5c5e\u6863\u6848<\/p>\n  <p style=\"margin-top:12px;\">\u6863\u6848\u7f16\u53f7\uff1aR-B-H-002 \uff5c \u7f16\u5236\u65e5\u671f\uff1a2026\u5e746\u670814\u65e5 \uff5c \u7248\u672c\uff1aV1.0\uff08\u6863\u6848\u7248\uff09<\/p>\n  <p style=\"font-size:12px; color:#bdc3c7; margin-top:8px;\">\u672c\u6863\u6848\u7531\u9f99\u8109\u6696\u901a\u5ba2\u6237\u6210\u529f\u7cfb\u7edf\u81ea\u52a8\u751f\u6210\uff0c\u771f\u5b9e\u53ef\u67e5\u3002<\/p>\n  <a href=\"#top\" class=\"back-to-top\">\u2191 \u8fd4\u56de\u76ee\u5f55<\/a>\n<\/footer>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u4e13\u6ce8\u53ef\u89c6\u5316\u670d\u52a1 \ud83d\udd25  [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3246","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u4e13\u6ce8\u53ef\u89c6\u5316\u670d\u52a1 \ud83d\udd25 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=3246\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-23T09:41:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246\",\"name\":\"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/RHJ-CLS-NQSG01.jpg\",\"datePublished\":\"2026-06-14T06:07:47+00:00\",\"dateModified\":\"2026-10-23T09:41:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/RHJ-CLS-NQSG01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/RHJ-CLS-NQSG01.jpg\",\"width\":1440,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3246#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"zh_CN","og_type":"article","og_title":"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u4e13\u6ce8\u53ef\u89c6\u5316\u670d\u52a1 \ud83d\udd25 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=3246","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-23T09:41:33+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=3246","url":"https:\/\/longmai-nt.com\/?page_id=3246","name":"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=3246#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=3246#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG01.jpg","datePublished":"2026-06-14T06:07:47+00:00","dateModified":"2026-10-23T09:41:33+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=3246#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=3246"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=3246#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/RHJ-CLS-NQSG01.jpg","width":1440,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=3246#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4ec1\u548c\u885739\u53f7\u9662 \u00b7 \u5e38\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247-\u6863\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3246"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3246\/revisions"}],"predecessor-version":[{"id":3256,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3246\/revisions\/3256"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}