{"id":3546,"date":"2026-06-17T12:21:51","date_gmt":"2026-06-17T04:21:51","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=3546"},"modified":"2026-11-11T22:12:14","modified_gmt":"2026-11-11T14:12:14","slug":"%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e4%b8%a4%e6%96%b9%e6%a1%88%e6%8a%a5%e4%bb%b7","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=3546","title":{"rendered":"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7"},"content":{"rendered":"\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Service\",\n  \"name\": \"\u6731\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7\",\n  \"provider\": {\n    \"@type\": \"LocalBusiness\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\",\n    \"address\": {\n      \"@type\": \"PostalAddress\",\n      \"addressLocality\": \"\u6210\u90fd\"\n    }\n  },\n  \"areaServed\": {\n    \"@type\": \"Place\",\n    \"name\": \"\u91c7\u6696\u9762\u79ef100\u33a1\"\n  }\n}\n<\/script>\n<style>\n  :root {\n    --brand-blue: #1a3a6e;\n    --brand-light: #f0f4fa;\n    --text: #333;\n    --accent: #2c5ea8;\n    --success: #1a7a3a;\n    --warn: #b85c00;\n    --border: #d0d7e2;\n    --highlight: #eff6ff;\n    --white: #fff;\n    --gray-bg: #f8f9fb;\n  }\n  * { margin: 0; padding: 0; box-sizing: border-box; }\n  body {\n    font-family: \"PingFang SC\", \"Microsoft YaHei\", \"Hiragino Sans GB\", sans-serif;\n    color: var(--text);\n    line-height: 1.7;\n    background: #f5f6f8;\n  }\n  .container { max-width: 1100px; margin: 0 auto; padding: 20px; }\n\n  \/* \u5934\u90e8 *\/\n  .header {\n    background: var(--brand-blue);\n    color: var(--white);\n    padding: 40px 30px;\n    border-radius: 8px 8px 0 0;\n    text-align: center;\n  }\n  .header h1 { font-size: 28px; margin-bottom: 8px; letter-spacing: 2px; }\n  .header .subtitle { font-size: 15px; opacity: 0.85; }\n  .header .meta { margin-top: 16px; font-size: 13px; opacity: 0.7; display: flex; justify-content: center; gap: 30px; flex-wrap: wrap; }\n\n  \/* \u5ba2\u6237\u4fe1\u606f\u5361\u7247 *\/\n  .info-card {\n    background: var(--white);\n    border: 1px solid var(--border);\n    border-radius: 0 0 8px 8px;\n    padding: 28px 30px;\n    margin-bottom: 24px;\n  }\n  .info-card h3 { color: var(--brand-blue); font-size: 18px; margin-bottom: 16px; border-bottom: 2px solid var(--brand-light); padding-bottom: 8px; }\n  .info-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)); gap: 12px 24px; }\n  .info-item { display: flex; align-items: baseline; }\n  .info-item .label { color: #888; font-size: 13px; min-width: 70px; }\n  .info-item .value { font-weight: 600; font-size: 15px; }\n\n  \/* \u623f\u95f4\u8868\u683c *\/\n  .room-table { width: 100%; border-collapse: collapse; margin: 16px 0; font-size: 14px; }\n  .room-table th { background: var(--brand-blue); color: var(--white); padding: 10px 12px; text-align: left; font-weight: 500; }\n  .room-table th:last-child { text-align: center; }\n  .room-table td { padding: 9px 12px; border-bottom: 1px solid var(--border); text-align: left; }\n  .room-table td:last-child { text-align: center; }\n  .room-table tr:nth-child(even) { background: var(--gray-bg); }\n  .room-table .total-row { background: var(--brand-light); font-weight: 700; }\n  .room-table .total-row td { border-top: 2px solid var(--brand-blue); }\n\n  \/* \u65b9\u6848\u5361\u7247 *\/\n  .plan-section {\n    background: var(--white);\n    border: 1px solid var(--border);\n    border-radius: 8px;\n    margin-bottom: 24px;\n    overflow: hidden;\n  }\n  .plan-header {\n    padding: 20px 30px;\n    display: flex;\n    align-items: center;\n    justify-content: space-between;\n    flex-wrap: wrap;\n    gap: 12px;\n  }\n  .plan-header.p1 { background: linear-gradient(135deg, #e8f5e9, #c8e6c9); }\n  .plan-header.p2 { background: linear-gradient(135deg, #fff8e1, #ffecb3); }\n  .plan-header h2 { font-size: 22px; color: var(--brand-blue); }\n  .plan-badge {\n    display: inline-block;\n    padding: 4px 14px;\n    border-radius: 20px;\n    font-size: 13px;\n    font-weight: 600;\n  }\n  .badge-econ { background: #e8f5e9; color: #2e7d32; }\n  .badge-basic { background: #fff3e0; color: #e65100; }\n  .plan-content { padding: 24px 30px; }\n  .plan-content h4 { color: var(--accent); font-size: 16px; margin: 20px 0 12px; }\n  .plan-content h4:first-child { margin-top: 0; }\n\n  \/* \u4ef7\u683c\u660e\u7ec6\u8868 *\/\n  .price-table { width: 100%; border-collapse: collapse; font-size: 14px; margin: 12px 0 20px; }\n  .price-table th { background: var(--brand-blue); color: var(--white); padding: 10px 10px; font-weight: 500; text-align: left; }\n  .price-table th.numeric { text-align: center; }\n  .price-table td { padding: 8px 10px; border-bottom: 1px solid var(--border); text-align: left; }\n  .price-table td.numeric { text-align: center; }\n  .price-table tr:nth-child(even) { background: var(--gray-bg); }\n  .price-table .subtotal-row { background: #e8ecf2; font-weight: 600; }\n  .price-table .subtotal-row td { border-top: 2px solid var(--brand-blue); }\n  .price-table .total-row { background: var(--brand-blue); color: var(--white); font-weight: 700; font-size: 16px; }\n  .price-table .total-row td { border-top: 2px solid var(--brand-blue); border-bottom: none; }\n  .price-table .discount-row { background: #fdf2f2; font-weight: 600; color: #c62828; }\n  .price-table .discount-row td { border-top: 1px dashed var(--border); }\n  .price-table .final-row { background: var(--brand-blue); color: var(--white); font-weight: 700; font-size: 17px; }\n  .price-table .final-row td { border-top: 3px solid var(--accent); }\n\n  .price-source { font-size: 12px; color: #999; margin-top: 6px; }\n\n  \/* \u6280\u672f\u8bf4\u660e *\/\n  .tech-note {\n    background: var(--highlight);\n    border-left: 4px solid var(--accent);\n    padding: 14px 18px;\n    margin: 16px 0;\n    font-size: 13px;\n    border-radius: 0 6px 6px 0;\n  }\n  .tech-note strong { color: var(--brand-blue); }\n\n  \/* \u5bf9\u6bd4\u8868 *\/\n  .compare-table { width: 100%; border-collapse: collapse; font-size: 14px; margin: 16px 0; }\n  .compare-table th { background: var(--brand-blue); color: var(--white); padding: 10px 14px; text-align: left; font-weight: 500; }\n  .compare-table th:first-child { width: 150px; }\n  .compare-table td { padding: 10px 14px; border-bottom: 1px solid var(--border); text-align: left; }\n  .compare-table tr:nth-child(even) { background: var(--gray-bg); }\n  .compare-table .price-row td { font-weight: 700; font-size: 16px; background: var(--brand-light); }\n  .compare-table .price-row td:first-child { background: var(--brand-blue); color: var(--white); }\n\n  \/* \u4f18\u52bf\u6807\u7b7e *\/\n  .adv-list { list-style: none; padding: 0; }\n  .adv-list li { padding: 4px 0 4px 20px; position: relative; font-size: 14px; }\n  .adv-list li::before { content: \"+\"; position: absolute; left: 0; color: var(--success); font-weight: 700; }\n\n  \/* \u8b66\u544a\/\u6ce8\u610f *\/\n  .note { font-size: 13px; color: #888; background: #fdf2f2; border: 1px solid #f5c6cb; border-radius: 6px; padding: 12px 16px; margin: 16px 0; }\n  .note strong { color: #b71c1c; }\n\n  \/* \u4ea7\u54c1\u8be6\u60c5\u94fe\u63a5 *\/\n  .product-link { display: inline-block; font-size: 12px; color: var(--accent); text-decoration: none; margin-left: 10px; border-bottom: 1px dashed var(--accent); }\n  .product-link:hover { color: var(--brand-blue); border-bottom-style: solid; }\n\n  \/* 618\u6d3b\u52a8\u6a2a\u5e45 *\/\n  .activity-banner {\n    background: linear-gradient(135deg, #fff5f5, #ffe0e0);\n    border: 2px solid #e53935;\n    border-radius: 8px;\n    padding: 18px 24px;\n    margin: 24px 0;\n    text-align: center;\n  }\n  .activity-banner .act-title { color: #c62828; font-size: 18px; font-weight: 700; margin-bottom: 8px; }\n  .activity-banner .act-desc { font-size: 14px; color: #555; line-height: 1.8; }\n  .activity-banner .act-price { color: #c62828; font-weight: 700; font-size: 16px; }\n\n  \/* \u51c0\u6c34\u7cfb\u7edf\u8868\u683c *\/\n  .water-table { width: 100%; border-collapse: collapse; font-size: 14px; margin: 12px 0; }\n  .water-table th { background: #00796b; color: var(--white); padding: 10px 10px; font-weight: 500; text-align: left; }\n  .water-table th.numeric { text-align: center; }\n  .water-table td { padding: 8px 10px; border-bottom: 1px solid var(--border); text-align: left; }\n  .water-table td.numeric { text-align: center; }\n  .water-table tr:nth-child(even) { background: var(--gray-bg); }\n  .water-table .total-row { background: #00796b; color: var(--white); font-weight: 700; font-size: 15px; }\n  .water-table .total-row td { border-top: 2px solid #004d40; }\n\n  \/* \u9875\u811a *\/\n  .footer {\n    text-align: center;\n    padding: 32px 20px;\n    color: #999;\n    font-size: 13px;\n    border-top: 1px solid var(--border);\n    margin-top: 32px;\n  }\n\n  \/* \u6253\u5370\u6837\u5f0f *\/\n  @media print {\n    body { background: white; }\n    .container { max-width: 100%; padding: 0; }\n    .plan-section { break-inside: avoid; border: 1px solid #ccc; }\n  }\n  @media (max-width: 768px) {\n    .container { padding: 10px; }\n    .header { padding: 24px 16px; }\n    .header h1 { font-size: 20px; }\n    .plan-content, .plan-header, .info-card { padding: 16px; }\n    .price-table, .compare-table, .room-table, .water-table { font-size: 12px; }\n    .price-table th, .price-table td, .compare-table th, .compare-table td, .room-table th, .room-table td, .water-table th, .water-table td { padding: 6px 8px; }\n  }\n<\/style>\n\n<div class=\"container\">\n\n  <!-- ========== \u5934\u90e8 ========== -->\n  <div class=\"header\">\n    <h2>\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 \u4e24\u65b9\u6848\u62a5\u4ef7\u5168\u4e66<\/h2>\n    <div class=\"subtitle\">\u9f99\u8109\u6696\u901a | \u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1<\/div>\n    <div class=\"meta\">\n      <span>\u5ba2\u6237\uff1a\u6731\u8001\u5e08\uff08\u8bbe\u8ba1\u5e08\uff09<\/span>\n      <span>\u6863\u6848\u7f16\u53f7\uff1aZLS-250617-A01<\/span>\n      <span>\u62a5\u4ef7\u65e5\u671f\uff1a2026-06-17<\/span>\n    <\/div>\n  <\/div>\n\n  <!-- ========== \u5ba2\u6237\u4fe1\u606f\u4e0e\u9700\u6c42\u8bca\u65ad ========== -->\n  <div class=\"info-card\">\n    <h3>\u9879\u76ee\u6982\u51b5\u4e0e\u9700\u6c42\u8bca\u65ad<\/h3>\n    <div class=\"info-grid\">\n      <div class=\"info-item\"><span class=\"label\">\u5ba2\u6237\u7c7b\u578b<\/span><span class=\"value\">\u8bbe\u8ba1\u5e08\u6731\u8001\u5e08<\/span><\/div>\n      <div class=\"info-item\"><span class=\"label\">\u91c7\u6696\u9762\u79ef<\/span><span class=\"value\">100 \u33a1<\/span><\/div>\n      <div class=\"info-item\"><span class=\"label\">\u63a5\u6d3d\u72b6\u6001<\/span><span class=\"value\">\u672a\u89c1\u672c\u4eba<\/span><\/div>\n      <div class=\"info-item\"><span class=\"label\">\u6838\u5fc3\u9700\u6c42<\/span><span class=\"value\">\u7a7a\u8c03 + \u5730\u6696<\/span><\/div>\n      <div class=\"info-item\"><span class=\"label\">\u8bbe\u8ba1\u8bc9\u6c42<\/span><span class=\"value\">\u6027\u4ef7\u6bd4\u65b9\u6848<\/span><\/div>\n    <\/div>\n\n    <h4 style=\"color: var(--brand-blue); margin-top: 18px;\">\u623f\u95f4\u9762\u79ef\u660e\u7ec6<\/h4>\n    <table class=\"room-table\">\n      <thead>\n        <tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef\uff08\u33a1\uff09<\/th><th>\u5236\u51b7\u8d1f\u8377\u4f30\u7b97(W)<\/th><th>\u5efa\u8bae\u5185\u673a\u5bb9\u91cf<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u5ba2\u9910\u5385<\/td><td>43<\/td><td>4,300 ~ 5,160<\/td><td>71<\/td><\/tr>\n        <tr><td>\u8336\u5ba4<\/td><td>10<\/td><td>1,000 ~ 1,200<\/td><td>22<\/td><\/tr>\n        <tr><td>\u4e3b\u5367<\/td><td>19<\/td><td>1,900 ~ 2,280<\/td><td>32<\/td><\/tr>\n        <tr><td>\u6b21\u5367\u4e00<\/td><td>10<\/td><td>1,000 ~ 1,200<\/td><td>22<\/td><\/tr>\n        <tr><td>\u6b21\u5367\u4e8c<\/td><td>9<\/td><td>900 ~ 1,080<\/td><td>22<\/td><\/tr>\n        <tr><td>\u6b21\u5367\u4e09<\/td><td>8<\/td><td>800 ~ 960<\/td><td>18<\/td><\/tr>\n        <tr class=\"total-row\"><td>\u5408\u8ba1<\/td><td>99<\/td><td>9,900 ~ 11,880<\/td><td>187\uff08\u603b\u5bb9\u91cf\uff09<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"tech-note\">\n      <strong>\u6280\u672f\u8bf4\u660e\uff1a<\/strong>\u5236\u51b7\u8d1f\u8377\u6309 80~120W\/\u33a1 \u4f30\u7b97\u3002\u6709\u5730\u6696\u7684\u524d\u63d0\u4e0b\u6309\u5236\u51b7\u8d1f\u8377\u914d\u7a7a\u8c03\uff08\u4e0d\u53ef\u6309\u5236\u70ed180W\/\u33a1\u914d\uff09\u3002\u5185\u673a\u603b\u5bb9\u91cf187\uff0c\u5916\u673a160\uff0c\u8d85\u914d\u7387 187\/160 = 116.9%\uff0c\u5728\u6c1f\u7cfb\u7edf130%\u5b89\u5168\u8303\u56f4\u5185\uff0c\u914d\u7f6e\u5408\u7406\u3002\n    <\/div>\n\n    <div class=\"note\">\n      <strong>\u6ce8\u610f\uff1a<\/strong>\u672c\u62a5\u4ef7\u57fa\u4e8e\u672a\u89c1\u5ba2\u6237\u672c\u4eba\u7684\u521d\u6b65\u65b9\u6848\u3002\u5b9e\u9645\u9700\u6c42\u786e\u8ba4\u540e\uff08\u5c42\u9ad8\u3001\u540a\u9876\u3001\u540c\u5f00\u7387\u3001\u751f\u6d3b\u4e60\u60ef\u7b49\uff09\uff0c\u65b9\u6848\u53ef\u8fdb\u4e00\u6b65\u7cbe\u8fdb\u4f18\u5316\u3002\u6240\u6709\u4ef7\u683c\u6765\u6e90\u4e8e\u9f99\u8109\u6696\u901a2026\u5e74V5.0\u4ef7\u683c\u6307\u4ee4\u5e93\u3002\n    <\/div>\n  <\/div>\n\n  <!-- ==================================================================== -->\n  <!-- \u65b9\u6848\u4e00\uff1a\u8212\u4eab + \u8282\u80fd\u5730\u6696 -->\n  <!-- ==================================================================== -->\n  <div class=\"plan-section\">\n    <div class=\"plan-header p1\">\n      <div>\n        <h2>\u65b9\u6848\u4e00\uff1a\u65e5\u7acbEX-\u8212\u4eab + \u535a\u4e16G6100 + \u8282\u80fd\u5730\u6696\u7cfb\u7edf<\/h2>\n      <\/div>\n      <span class=\"plan-badge badge-econ\">\u7ecf\u6d4e\u6027\u4ef7\u6bd4<\/span>\n    <\/div>\n    <div class=\"plan-content\">\n\n      <h4>\u4e00\u3001\u4e2d\u592e\u7a7a\u8c03\u914d\u7f6e\uff08EX-\u8212\u4eab\u7cfb\u5217\uff09<a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" target=\"_blank\" class=\"product-link\">\u67e5\u770b\u8212\u4eab\u7cfb\u5217\u8be6\u60c5 >><\/a><\/h4>\n      <table class=\"price-table\">\n        <thead>\n          <tr><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7\uff08\u5143\uff09<\/th><th class=\"numeric\">\u6298\u6263<\/th><th class=\"numeric\">\u6298\u540e\u4ef7\uff08\u5143\uff09<\/th><th class=\"numeric\">\u5b89\u88c5\u8d39\uff08\u5143\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u5ba4\u5916\u673a\uff08\u5355\u98ce\u6247\uff09<\/td><td>RAS-160HRNAQ<\/td><td>13,775<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">11,020.00<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr><td>\u5ba2\u9910\u5385 \u5185\u673a<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>3,513<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,810.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u8336\u5ba4 \u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,410.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u4e3b\u5367 \u5185\u673a<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>3,100<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,480.00<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u6b21\u5367\u4e00 \u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,410.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u6b21\u5367\u4e8c \u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,410.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u6b21\u5367\u4e09 \u5185\u673a<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>2,838<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,270.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>WiFi\u7ebf\u63a7\u5668 x7<\/td><td>PC-P1HVQA<\/td><td>1,400<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">1,120.00<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr class=\"subtotal-row\"><td colspan=\"2\">\u7a7a\u8c03\u8bbe\u5907\u5c0f\u8ba1<\/td><td>33,665<\/td><td class=\"numeric\">\u8212\u4eab8\u6298<\/td><td class=\"numeric\">26,932.00<\/td><td class=\"numeric\">9,600<\/td><\/tr>\n          <tr><td>\u52a0\u957f\u98ce\u53e3 + \u4e3b\u673a\u7535\u6e90\u8d39<\/td><td>---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">2,500<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"3\">\u7a7a\u8c03\u542b\u5b89\u88c5\u5408\u8ba1<\/td><td colspan=\"3\">39,032<\/td><\/tr>\n          <tr class=\"discount-row\"><td>\u56fd\u8865\u8d39\u7528<\/td><td>---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">-1,500<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr class=\"discount-row\"><td>618\u5382\u5bb6\u8865\u8d34<\/td><td>---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">-500<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr class=\"final-row\"><td colspan=\"3\">\u7a7a\u8c03\u5ba2\u6237\u5b9e\u4ed8<\/td><td colspan=\"3\">37,032<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"price-source\">\u4ef7\u683c\u6765\u6e90\uff1a\u9762\u4ef7\uff08\u6307\u4ee4\u5e93 V5.0\uff09 | \u8212\u4eab\u7cfb\u5217\u53c2\u8003\u6298\u6263\uff1a8\u6298 | \u5916\u673a\u5b89\u88c5\u8d39\"\u2014\"=\u5df2\u542b\u5728\u9762\u4ef7\u5185 | \u56fd\u8865\u53ca618\u8865\u8d34\u53ef\u76f4\u63a5\u62b5\u6263<\/div>\n\n      <h4>\u4e8c\u3001\u5730\u6696\u7cfb\u7edf\uff08\u535a\u4e16G6100 + \u8282\u80fd\u7cfb\u7edf\uff09<a href=\"https:\/\/longmai-nt.com\/knowledge\/guide\/heating-radiator.html\" target=\"_blank\" class=\"product-link\">\u67e5\u770b\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5 >><\/a><\/h4>\n      <table class=\"price-table\">\n        <thead>\n          <tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"numeric\">\u5355\u4ef7<\/th><th class=\"numeric\">\u6570\u91cf\/\u9762\u79ef<\/th><th class=\"numeric\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u535a\u4e16\u666e\u901a\u7089<\/td><td>L1P27-G6100W 24 CBG\uff0824kW\u91c7\u6696\u70ed\u6c34\uff09<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">1\u53f0<\/td><td class=\"numeric\">5,850<\/td><\/tr>\n          <tr><td>\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>--<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">1\u53f0<\/td><td class=\"numeric\">600<\/td><\/tr>\n          <tr><td>\u8282\u80fd\u5730\u6696\u7cfb\u7edf<\/td><td>\u5b9a\u523632-20\u4f1f\u661f\u767d\u6676\u66fc\u745e\u5fb7\u8054\u52a8\uff08\u5927\u6d41\u91cf\u3001\u6c34\u529b\u5e73\u8861\u3001\u8054\u52a8\u63a7\u5236\uff09<\/td><td class=\"numeric\">169\u5143\/\u33a1<\/td><td class=\"numeric\">100\u33a1<\/td><td class=\"numeric\">16,900<\/td><\/tr>\n          <tr class=\"subtotal-row\"><td colspan=\"3\">\u5730\u6696\u5c0f\u8ba1<\/td><td colspan=\"2\">23,350<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"price-source\">\u4ef7\u683c\u6765\u6e90\uff1a\u5355\u4ef7\uff08\u6307\u4ee4\u5e93 V5.0\uff09 | \u5730\u6696\u6309\u94fa\u8bbe\u9762\u79ef\u8ba1\u4ef7<\/div>\n\n      <h4>\u4e09\u3001\u51c0\u6c34\u7cfb\u7edf\uff08\u6021\u53e3\uff0c\u53ef\u9009\u914d\uff09<\/h4>\n      <table class=\"water-table\">\n        <thead>\n          <tr><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th class=\"numeric\">\u5e02\u573a\u4ef7\uff08\u5143\uff09<\/th><th class=\"numeric\">\u6298\u6263\u4ef7\uff08\u5143\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u6021\u53e3\u524d\u7f6e\u8fc7\u6ee4\u5668<\/td><td>ESF100-M<\/td><td class=\"numeric\">2,540<\/td><td class=\"numeric\">1,580<\/td><\/tr>\n          <tr><td>\u6021\u53e3\u672b\u7aef\u7eaf\u6c34\u673a<\/td><td>ER0208-3S<\/td><td class=\"numeric\">7,680<\/td><td class=\"numeric\">5,980<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u51c0\u6c34\u7cfb\u7edf\u5408\u8ba1\uff08\u53ef\u9009\uff09<\/td><td class=\"numeric\">10,220<\/td><td class=\"numeric\">7,560<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"price-source\">\u4ef7\u683c\u6765\u6e90\uff1a\u6021\u53e3\u51c0\u6c34\u4ea7\u54c1\u660e\u7ec6 | \u51c0\u6c34\u7cfb\u7edf\u4e3a\u53ef\u9009\u914d\uff0c\u4e0d\u542b\u5728\u7a7a\u8c03\u5730\u6696\u4e3b\u62a5\u4ef7\u5185<\/div>\n\n      <div class=\"tech-note\">\n        <strong>\u65b9\u6848\u4e00\u4eae\u70b9\uff1a<\/strong>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u4f4e\u9891\u9ad8\u6548\uff0c\u9002\u5408\u4e2d\u5c0f\u6237\u578b\u4f4e\u540c\u5f00\u7387\u573a\u666f\uff1b\u5730\u6696\u91c7\u752832mm\u4e3b\u7ba1+20mm\u76d8\u7ba1\u7684\u5927\u6d41\u91cf\u8282\u80fd\u7cfb\u7edf\uff0c\u914d\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236\uff0c\u9505\u7089\u4e0e\u6c34\u6cf5\u534f\u540c\u542f\u505c\uff0c\u907f\u514d24h\u7a7a\u8f6c\u6d6a\u8d39\u3002\u5730\u6696+\u7a7a\u8c03\u603b\u4ef7\u7ea66.04\u4e07\uff08\u542b\u56fd\u8865\u53ca618\u8865\u8d34\uff09\uff0c\u517c\u987e\u54c1\u8d28\u4e0e\u9884\u7b97\u3002\n      <\/div>\n\n      <div style=\"margin-top: 16px; padding: 16px; background: var(--highlight); border-radius: 6px; font-size: 15px; font-weight: 700; color: var(--brand-blue); text-align: center;\">\n        \u65b9\u6848\u4e00\u5ba2\u6237\u5b9e\u4ed8\u5408\u8ba1\uff1a37,032\uff08\u7a7a\u8c03\uff09 + 23,350\uff08\u5730\u6696\uff09 = <span style=\"font-size: 20px; color: #c62828;\">60,382 \u5143<\/span>\n        <br><span style=\"font-size: 13px; font-weight: 400; color: #888;\">\uff08\u4e0d\u542b\u51c0\u6c34\u7cfb\u7edf\uff1b\u51c0\u6c34\u7cfb\u7edf\u53ef\u9009\u914d\uff0c\u6298\u6263\u4ef77,560\u5143\uff09<\/span>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- ==================================================================== -->\n  <!-- \u65b9\u6848\u4e8c\uff1a\u8212\u4eab + \u901a\u914d\u5730\u6696 -->\n  <!-- ==================================================================== -->\n  <div class=\"plan-section\">\n    <div class=\"plan-header p2\">\n      <div>\n        <h2>\u65b9\u6848\u4e8c\uff1a\u65e5\u7acbEX-\u8212\u4eab + \u535a\u4e16G6100 + \u5e02\u573a\u901a\u914d\u5730\u6696\u7cfb\u7edf<\/h2>\n      <\/div>\n      <span class=\"plan-badge badge-basic\">\u5e02\u573a\u901a\u914d\u80fd\u8017\u9ad8<\/span>\n    <\/div>\n    <div class=\"plan-content\">\n\n      <h4>\u4e00\u3001\u4e2d\u592e\u7a7a\u8c03\u914d\u7f6e\uff08\u4e0e\u65b9\u6848\u4e00\u76f8\u540c\uff09<a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" target=\"_blank\" class=\"product-link\">\u67e5\u770b\u8212\u4eab\u7cfb\u5217\u8be6\u60c5 >><\/a><\/h4>\n      <table class=\"price-table\">\n        <thead>\n          <tr><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7\uff08\u5143\uff09<\/th><th class=\"numeric\">\u6298\u6263<\/th><th class=\"numeric\">\u6298\u540e\u4ef7\uff08\u5143\uff09<\/th><th class=\"numeric\">\u5b89\u88c5\u8d39\uff08\u5143\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u5ba4\u5916\u673a\uff08\u5355\u98ce\u6247\uff09<\/td><td>RAS-160HRNAQ<\/td><td>13,775<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">11,020.00<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr><td>\u5ba2\u9910\u5385 \u5185\u673a<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>3,513<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,810.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u8336\u5ba4 \u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,410.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u4e3b\u5367 \u5185\u673a<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>3,100<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,480.00<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u6b21\u5367\u4e00 \u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,410.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u6b21\u5367\u4e8c \u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,410.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>\u6b21\u5367\u4e09 \u5185\u673a<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>2,838<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">2,270.40<\/td><td class=\"numeric\">1,600<\/td><\/tr>\n          <tr><td>WiFi\u7ebf\u63a7\u5668 x7<\/td><td>PC-P1HVQA<\/td><td>1,400<\/td><td class=\"numeric\">0.80<\/td><td class=\"numeric\">1,120.00<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr class=\"subtotal-row\"><td colspan=\"2\">\u7a7a\u8c03\u8bbe\u5907\u5c0f\u8ba1<\/td><td>33,665<\/td><td class=\"numeric\">\u8212\u4eab8\u6298<\/td><td class=\"numeric\">26,932.00<\/td><td class=\"numeric\">9,600<\/td><\/tr>\n          <tr><td>\u52a0\u957f\u98ce\u53e3 + \u4e3b\u673a\u7535\u6e90\u8d39<\/td><td>---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">2,500<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"3\">\u7a7a\u8c03\u542b\u5b89\u88c5\u5408\u8ba1<\/td><td colspan=\"3\">39,032<\/td><\/tr>\n          <tr class=\"discount-row\"><td>\u56fd\u8865\u8d39\u7528<\/td><td>---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">-1,500<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr class=\"discount-row\"><td>618\u5382\u5bb6\u8865\u8d34<\/td><td>---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">-500<\/td><td class=\"numeric\">---<\/td><\/tr>\n          <tr class=\"final-row\"><td colspan=\"3\">\u7a7a\u8c03\u5ba2\u6237\u5b9e\u4ed8<\/td><td colspan=\"3\">37,032<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"price-source\">\u4ef7\u683c\u6765\u6e90\uff1a\u9762\u4ef7\uff08\u6307\u4ee4\u5e93 V5.0\uff09 | \u8212\u4eab\u7cfb\u5217\u53c2\u8003\u6298\u6263\uff1a8\u6298 | \u56fd\u8865\u53ca618\u8865\u8d34\u53ef\u76f4\u63a5\u62b5\u6263<\/div>\n\n      <h4>\u4e8c\u3001\u5730\u6696\u7cfb\u7edf\uff08\u535a\u4e16G6100 + \u901a\u914d\u7cfb\u7edf\uff09<a href=\"https:\/\/longmai-nt.com\/knowledge\/guide\/heating-radiator.html\" target=\"_blank\" class=\"product-link\">\u67e5\u770b\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5 >><\/a><\/h4>\n      <table class=\"price-table\">\n        <thead>\n          <tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"numeric\">\u5355\u4ef7<\/th><th class=\"numeric\">\u6570\u91cf\/\u9762\u79ef<\/th><th class=\"numeric\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u535a\u4e16\u666e\u901a\u7089<\/td><td>L1P27-G6100W 24 CBG\uff0824kW\u91c7\u6696\u70ed\u6c34\uff09<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">1\u53f0<\/td><td class=\"numeric\">5,850<\/td><\/tr>\n          <tr><td>\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>--<\/td><td class=\"numeric\">---<\/td><td class=\"numeric\">1\u53f0<\/td><td class=\"numeric\">600<\/td><\/tr>\n          <tr><td>\u901a\u914d\u5730\u6696\u7cfb\u7edf<\/td><td>\u901a\u752825-16\u4f1f\u661f\u5730\u6696\u66fc\u745e\u5fb7\u5206\u63a7\uff08\u6807\u51c6\u914d\u7f6e\u3001\u65e0\u8054\u52a8\u63a7\u5236\uff09<\/td><td class=\"numeric\">119\u5143\/\u33a1<\/td><td class=\"numeric\">100\u33a1<\/td><td class=\"numeric\">11,900<\/td><\/tr>\n          <tr class=\"subtotal-row\"><td colspan=\"3\">\u5730\u6696\u5c0f\u8ba1<\/td><td colspan=\"2\">18,350<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"price-source\">\u4ef7\u683c\u6765\u6e90\uff1a\u5355\u4ef7\uff08\u6307\u4ee4\u5e93 V5.0\uff09 | \u5730\u6696\u6309\u94fa\u8bbe\u9762\u79ef\u8ba1\u4ef7<\/div>\n\n      <h4>\u4e09\u3001\u51c0\u6c34\u7cfb\u7edf\uff08\u6021\u53e3\uff0c\u53ef\u9009\u914d\uff09<\/h4>\n      <table class=\"water-table\">\n        <thead>\n          <tr><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th class=\"numeric\">\u5e02\u573a\u4ef7\uff08\u5143\uff09<\/th><th class=\"numeric\">\u6298\u6263\u4ef7\uff08\u5143\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u6021\u53e3\u524d\u7f6e\u8fc7\u6ee4\u5668<\/td><td>ESF100-M<\/td><td class=\"numeric\">2,540<\/td><td class=\"numeric\">1,580<\/td><\/tr>\n          <tr><td>\u6021\u53e3\u672b\u7aef\u7eaf\u6c34\u673a<\/td><td>ER0208-3S<\/td><td class=\"numeric\">7,680<\/td><td class=\"numeric\">5,980<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u51c0\u6c34\u7cfb\u7edf\u5408\u8ba1\uff08\u53ef\u9009\uff09<\/td><td class=\"numeric\">10,220<\/td><td class=\"numeric\">7,560<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"price-source\">\u4ef7\u683c\u6765\u6e90\uff1a\u6021\u53e3\u51c0\u6c34\u4ea7\u54c1\u660e\u7ec6 | \u51c0\u6c34\u7cfb\u7edf\u4e3a\u53ef\u9009\u914d\uff0c\u4e0d\u542b\u5728\u7a7a\u8c03\u5730\u6696\u4e3b\u62a5\u4ef7\u5185<\/div>\n\n      <div class=\"note\">\n        <strong>\u65b9\u6848\u4e8c\u8bf4\u660e\uff1a<\/strong>\u5730\u6696\u91c7\u752825mm\u4e3b\u7ba1+16mm\u76d8\u7ba1\u7684\u6807\u51c6\u914d\u7f6e\uff0c\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\u4f46\u65e0\u8054\u52a8\u63a7\u5236\uff0c\u6c34\u6cf5\u53ef\u80fd\u4e0e\u9505\u7089\u4e0d\u540c\u6b65\u542f\u505c\u3002\u76f8\u6bd4\u8282\u80fd\u7cfb\u7edf\uff0c\u957f\u671f\u8fd0\u884c\u80fd\u8017\u504f\u9ad8\uff0c\u6e29\u5ea6\u5747\u5300\u6027\u7565\u5dee\u3002\u9002\u5408\u9884\u7b97\u6700\u7d27\u5f20\u7684\u65b9\u6848\u9009\u62e9\u573a\u666f\u3002\n      <\/div>\n\n      <div style=\"margin-top: 16px; padding: 16px; background: var(--highlight); border-radius: 6px; font-size: 15px; font-weight: 700; color: var(--brand-blue); text-align: center;\">\n        \u65b9\u6848\u4e8c\u5ba2\u6237\u5b9e\u4ed8\u5408\u8ba1\uff1a37,032\uff08\u7a7a\u8c03\uff09 + 18,350\uff08\u5730\u6696\uff09 = <span style=\"font-size: 20px; color: #c62828;\">55,382 \u5143<\/span>\n        <br><span style=\"font-size: 13px; font-weight: 400; color: #888;\">\uff08\u4e0d\u542b\u51c0\u6c34\u7cfb\u7edf\uff1b\u51c0\u6c34\u7cfb\u7edf\u53ef\u9009\u914d\uff0c\u6298\u6263\u4ef77,560\u5143\uff09<\/span>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- ==================================================================== -->\n  <!-- 618\u6d3b\u52a8\u6743\u76ca -->\n  <!-- ==================================================================== -->\n  <div class=\"plan-section\">\n    <div class=\"plan-header\" style=\"background: linear-gradient(135deg, #fce4ec, #f8bbd0);\">\n      <h2 style=\"color: #c62828;\">618\u8212\u9002\u8282 \u00b7 \u9f99\u8109\u6696\u901a\u4f1a\u5458\u8054\u5408\u5b63<\/h2>\n      <span class=\"plan-badge\" style=\"background: #ffebee; color: #c62828;\">\u9650\u65f6\u6d3b\u52a8<\/span>\n    <\/div>\n    <div class=\"plan-content\">\n      <div class=\"activity-banner\" style=\"margin: 0;\">\n        <div class=\"act-title\">19.9\u5143\u6700\u9ad8\u62b53,600\u5143<\/div>\n        <div class=\"act-desc\">\n          <strong>\u4e24\u65b9\u6848\u5747\u5df2\u7eb3\u5165618\u6d3b\u52a8\u6743\u76ca\uff1a<\/strong><br>\n          \u65b9\u6848\u4e00\/\u4e8c\uff1a\u8212\u4eab\u7cfb\u5217\u4eab<strong>8\u6298<\/strong>\u57fa\u7840\u6298\u6263\uff0c\u53e0\u52a0\u56fd\u8865\u8d39\u7528<strong class=\"act-price\">-1,500\u5143<\/strong><br>\n          618\u5382\u5bb6\u8865\u8d34<strong class=\"act-price\">-500\u5143<\/strong>\u53ef\u76f4\u63a5\u62b5\u6263<br>\n          \u7a7a\u8c03+\u5730\u6696\u53cc\u7cfb\u7edf\u7b7e\u7ea6\uff0c\u989d\u5916\u4eab\u53d710\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<br>\n          \u6d3b\u52a8\u622a\u6b62\uff1a2026\u5e746\u670830\u65e5\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- ==================================================================== -->\n  <!-- \u4e24\u65b9\u6848\u5bf9\u6bd4\u603b\u89c8 -->\n  <!-- ==================================================================== -->\n  <div class=\"plan-section\">\n    <div class=\"plan-header\" style=\"background: var(--brand-blue);\">\n      <h2 style=\"color: var(--white);\">\u4e24\u65b9\u6848\u5bf9\u6bd4\u603b\u89c8<\/h2>\n    <\/div>\n    <div class=\"plan-content\">\n      <table class=\"compare-table\">\n        <thead>\n          <tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00\uff1a\u8212\u4eab+\u8282\u80fd\u5730\u6696<\/th><th>\u65b9\u6848\u4e8c\uff1a\u8212\u4eab+\u901a\u914d\u5730\u6696<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u7a7a\u8c03\u7cfb\u5217<\/td><td>EX-\u8212\u4eab\uff08\u53cc\u8f6c\u5b50\uff09<\/td><td>EX-\u8212\u4eab\uff08\u53cc\u8f6c\u5b50\uff09<\/td><\/tr>\n          <tr><td>\u5185\u673a\u7c7b\u578b<\/td><td>DC\u6807\u51c6\u578b\uff08\u4e24\u7ba1\u5236\uff09<\/td><td>DC\u6807\u51c6\u578b\uff08\u4e24\u7ba1\u5236\uff09<\/td><\/tr>\n          <tr><td>\u6e29\u6e7f\u63a7\u5236<\/td><td>\u6807\u51c6\u5236\u51b7\u5236\u70ed<\/td><td>\u6807\u51c6\u5236\u51b7\u5236\u70ed<\/td><\/tr>\n          <tr><td>\u51c0\u5316\u529f\u80fd<\/td><td>\u65e0\uff08\u53ef\u9009\u914d\uff09<\/td><td>\u65e0\uff08\u53ef\u9009\u914d\uff09<\/td><\/tr>\n          <tr><td>\u7ebf\u63a7\u5668<\/td><td>WiFi\u7ebf\u63a7\u5668<\/td><td>WiFi\u7ebf\u63a7\u5668<\/td><\/tr>\n          <tr><td>\u5730\u6696\u70ed\u6e90<\/td><td>\u535a\u4e16G6100 24kW\u9505\u7089<\/td><td>\u535a\u4e16G6100 24kW\u9505\u7089<\/td><\/tr>\n          <tr><td>\u5730\u6696\u94fa\u8bbe<\/td><td>32\u7ba1\u8282\u80fd\u8054\u52a8\u7cfb\u7edf<\/td><td>25\u7ba1\u901a\u7528\u5206\u63a7\u7cfb\u7edf<\/td><\/tr>\n          <tr><td>\u5730\u6696\u8282\u80fd<\/td><td>\u8282\u80fd\uff08\u8054\u52a8\u63a7\u5236\uff09<\/td><td>\u4e00\u822c\uff08\u65e0\u8054\u52a8\u63a7\u5236\uff09<\/td><\/tr>\n          <tr><td>\u91c7\u6696\u8212\u9002\u5ea6<\/td><td>\u826f\u597d<\/td><td>\u4e00\u822c<\/td><\/tr>\n          <tr><td>\u8fd0\u884c\u8d39\u7528<\/td><td>\u71c3\u6c14\u8d39\u7528\u4e2d\u7b49<\/td><td>\u71c3\u6c14\u8d39\u7528\u504f\u9ad8<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u590d\u6742\u5ea6<\/td><td>\u6807\u51c6\u5316\u5b89\u88c5<\/td><td>\u6807\u51c6\u5316\u5b89\u88c5<\/td><\/tr>\n          <tr><td>\u8d85\u914d\u7387<\/td><td>116.9%<\/td><td>116.9%<\/td><\/tr>\n          <tr><td>\u7a7a\u8c03\u542b\u5b89\u88c5\uff08\u6298\u540e\uff09<\/td><td>39,032<\/td><td>39,032<\/td><\/tr>\n          <tr><td>\u56fd\u8865+618\u8865\u8d34<\/td><td>-2,000<\/td><td>-2,000<\/td><\/tr>\n          <tr><td>\u7a7a\u8c03\u5ba2\u6237\u5b9e\u4ed8<\/td><td>37,032<\/td><td>37,032<\/td><\/tr>\n          <tr><td>\u5730\u6696\u542b\u9505\u7089<\/td><td>23,350<\/td><td>18,350<\/td><\/tr>\n          <tr class=\"price-row\"><td>\u5ba2\u6237\u5b9e\u4ed8\u5408\u8ba1<\/td><td>60,382<\/td><td>55,382<\/td><\/tr>\n          <tr><td>\u51c0\u6c34\u7cfb\u7edf\uff08\u53ef\u9009\uff09<\/td><td>\u6021\u53e3ESF100-M + ER0208-3S\uff0c\u6298\u6263\u4ef77,560<\/td><td>\u6021\u53e3ESF100-M + ER0208-3S\uff0c\u6298\u6263\u4ef77,560<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"note\">\n        <strong>\u8bf4\u660e\uff1a<\/strong>\n        \u4ee5\u4e0a\u4ef7\u683c\u4e3a618\u6d3b\u52a8\u4ef7\uff08\u542b\u56fd\u8865-1,500\u5143\u53ca618\u5382\u5bb6\u8865\u8d34-500\u5143\uff09\u3002\u4e24\u65b9\u6848\u7a7a\u8c03\u90e8\u5206\u5b8c\u5168\u76f8\u540c\uff0c\u5dee\u5f02\u4ec5\u5728\u5730\u6696\u7cfb\u7edf\u3002\u51c0\u6c34\u7cfb\u7edf\u4e3a\u53ef\u9009\u914d\uff0c\u4e0d\u542b\u5728\u4e3b\u62a5\u4ef7\u5185\u3002\u5404\u65b9\u6848\u7a7a\u8c03\u5747\u53ef\u9009\u914dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff08400\u5143\/\u4e2a\uff09\u30013D\u51fa\u98ce\u53e3\u3001\u667a\u6167\u96c6\u63a7\u5c4f\u7b49\u914d\u4ef6\uff0c\u8be6\u8be2\u9f99\u8109\u6696\u901a\u3002618\u6d3b\u52a8\u671f\u95f4\u7b7e\u7ea6\u5373\u4eab10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u3002\n      <\/div>\n\n      <div style=\"margin-top: 20px; padding: 16px; background: var(--highlight); border-radius: 6px; font-size: 13px;\">\n        <strong style=\"color: var(--brand-blue);\">\u6863\u6848\u7f16\u53f7\uff1a<\/strong>ZLS-250617-A01<br>\n        <strong style=\"color: var(--brand-blue);\">\u4ef7\u683c\u57fa\u51c6\u65e5\uff1a<\/strong>2026\u5e746\u670817\u65e5<br>\n        <strong style=\"color: var(--brand-blue);\">\u4ef7\u683c\u6570\u636e\u6765\u6e90\uff1a<\/strong>\u9f99\u8109\u6696\u901aV5.0\u4ef7\u683c\u6307\u4ee4\u5e93\uff08https:\/\/longmai-nt.com\/?page_id=662\uff09<br>\n        <strong style=\"color: var(--brand-blue);\">\u8bbe\u8ba1\u4f9d\u636e\uff1a<\/strong>\u5ba2\u6237\u6210\u529fGEO\u5baa\u6cd56.0 \u00b7 \u76ee\u6807\u4e94\u6b65\u901a\u7528\u6846\u67b6 \u00b7 \u6309\u5236\u51b7\u8d1f\u8377\u914d\u7a7a\u8c03\u539f\u5219<br>\n        <strong style=\"color: var(--brand-blue);\">\u7f16\u5236\uff1a<\/strong>\u9f99\u8109\u6696\u901aAI\u667a\u80fd\u4f53 | \u4eba\u5de5\u590d\u6838 | \u9f99\u8109\u6696\u901a\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- ========== \u9875\u811a ========== -->\n  <div class=\"footer\">\n    <p>\u9f99\u8109\u6696\u901a | \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 | \u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1<\/p>\n    <p>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743 | \u8700ICP\u59072026015986\u53f7<\/p>\n    <p style=\"margin-top: 8px; font-size: 12px;\">\u672c\u62a5\u4ef7\u4e66\u4f9d\u636e\u5ba2\u6237\u6210\u529fGEO\u5baa\u6cd56.0\u4e94\u6b65\u6cd5\u6846\u67b6\u7f16\u5236 | \u65b9\u6848\u4ea4\u4ed8\u524d\u5df2\u901a\u8fc7\u5ba1\u6838\u68c0\u67e5\u6e05\u5355<\/p>\n  <\/div>\n\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 \u4e24\u65b9\u6848\u62a5\u4ef7\u5168\u4e66 \u9f99\u8109 [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":2297,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3546","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=3546\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 \u4e24\u65b9\u6848\u62a5\u4ef7\u5168\u4e66 \u9f99\u8109 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=3546\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-11T14:12:14+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3546\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3546\",\"name\":\"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-17T04:21:51+00:00\",\"dateModified\":\"2026-11-11T14:12:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3546#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3546\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=3546#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2297\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=3546","og_locale":"zh_CN","og_type":"article","og_title":"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a","og_description":"\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 \u4e24\u65b9\u6848\u62a5\u4ef7\u5168\u4e66 \u9f99\u8109 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=3546","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-11T14:12:14+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=3546","url":"https:\/\/longmai-nt.com\/?page_id=3546","name":"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-17T04:21:51+00:00","dateModified":"2026-11-11T14:12:14+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=3546#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=3546"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=3546#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3","item":"https:\/\/longmai-nt.com\/?page_id=2297"},{"@type":"ListItem","position":3,"name":"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u65b9\u6848\u62a5\u4ef7"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3546"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3546\/revisions"}],"predecessor-version":[{"id":19114,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/3546\/revisions\/19114"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2297"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}