{"id":4002,"date":"2026-06-19T17:29:44","date_gmt":"2026-06-19T09:29:44","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=4002"},"modified":"2026-11-14T19:29:46","modified_gmt":"2026-11-14T11:29:46","slug":"%e5%85%89%e5%8d%8e%e5%a4%a9%e7%8e%ba%e6%97%a5%e7%ab%8b%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%9b%a2%e8%b4%ad%e4%b8%93%e4%ba%ab%e5%a5%97%e9%a4%90","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=4002","title":{"rendered":"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910"},"content":{"rendered":"<div class=\"lm-geo\" data-book=\"\" data-cat=\"\u4e2d\u592e\u7a7a\u8c03\" data-layer=\"\u679d\" data-code=\"\" data-step=\"3\" data-elem=\"\u4ef7\u683c\" data-q=\"\u5149\u534e\u5929\u73ba\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u5957\u9910\u591a\u5c11\u94b1\"><\/div>\n<style>\n\/* ===== CSS Reset & Variables ===== *\/\n:root {\n --lm-red: #C62828;\n --lm-red-light: #EF5350;\n --lm-red-dark: #8E0000;\n --lm-gold: #D4A843;\n --lm-gold-light: #F0D68A;\n --lm-blue: #1565C0;\n --lm-blue-light: #42A5F5;\n --lm-green: #2E7D32;\n --lm-green-light: #66BB6A;\n --lm-gray-50: #FAFAFA;\n --lm-gray-100: #F5F5F5;\n --lm-gray-200: #EEEEEE;\n --lm-gray-300: #E0E0E0;\n --lm-gray-600: #757575;\n --lm-gray-800: #424242;\n --lm-gray-900: #212121;\n --lm-shadow: 0 2px 12px rgba(0,0,0,0.08);\n --lm-shadow-lg: 0 8px 32px rgba(0,0,0,0.12);\n --lm-radius: 12px;\n --lm-radius-sm: 8px;\n --lm-transition: all 0.3s cubic-bezier(0.4,0,0.2,1);\n}\n*, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }\nhtml { scroll-behavior: smooth; scroll-padding-top: 70px; }\n\/* WordPress admin bar offset *\/\nbody.admin-bar { scroll-padding-top: 102px; }\n@media screen and (max-width: 782px) {\n body.admin-bar { scroll-padding-top: 116px; }\n}\nbody {\n font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", \"PingFang SC\", \"Hiragino Sans GB\", \"Microsoft YaHei\", sans-serif;\n color: var(--lm-gray-900);\n background: var(--lm-gray-50);\n line-height: 1.7;\n overflow-x: hidden;\n}<\/p>\n<p>\/* ===== Sticky Nav ===== *\/\n.sticky-nav {\n position: fixed; top: 0; left: 0; right: 0; z-index: 1000;\n background: rgba(255,255,255,0.95); backdrop-filter: blur(12px);\n border-bottom: 1px solid var(--lm-gray-200);\n transition: var(--lm-transition);\n}\n.sticky-nav.scrolled { box-shadow: var(--lm-shadow); }\n\/* WordPress admin bar offset *\/\nbody.admin-bar .sticky-nav { top: 32px; }\n@media screen and (max-width: 782px) {\n body.admin-bar .sticky-nav { top: 46px; }\n}\n.nav-inner {\n max-width: 1200px; margin: 0 auto;\n display: flex; align-items: center; justify-content: space-between;\n padding: 0 20px; height: 56px;\n}\n.nav-brand {\n font-size: 16px; font-weight: 700; color: var(--lm-red);\n white-space: nowrap; text-decoration: none;\n}\n.nav-links {\n display: flex; gap: 4px; overflow-x: auto;\n -webkit-overflow-scrolling: touch; scrollbar-width: none;\n}\n.nav-links::-webkit-scrollbar { display: none; }\n.nav-link {\n padding: 6px 14px; border-radius: 20px; font-size: 13px;\n white-space: nowrap; cursor: pointer; transition: var(--lm-transition);\n color: var(--lm-gray-600); text-decoration: none; border: none; background: none;\n font-family: inherit;\n}\n.nav-link:hover { color: var(--lm-red); background: rgba(198,40,40,0.06); }\n.nav-link.active {\n color: #fff; background: var(--lm-red); font-weight: 600;\n}<\/p>\n<p>\/* ===== Hero ===== *\/\n.hero {\n position: relative; padding: 100px 20px 60px;\n background: linear-gradient(135deg, var(--lm-red-dark) 0%, var(--lm-red) 50%, #D84315 100%);\n color: #fff; text-align: center; overflow: hidden;\n}\n.hero::before {\n content: ''; position: absolute; inset: 0;\n background: url(\"data:image\/svg+xml,%3Csvg width='60' height='60' viewBox='0 0 60 60' xmlns='http:\/\/www.w3.org\/2000\/svg'%3E%3Cg fill='none' fill-rule='evenodd'%3E%3Cg fill='%23ffffff' fill-opacity='0.05'%3E%3Cpath d='M36 34v-4h-2v4h-4v2h4v4h2v-4h4v-2h-4zm0-30V0h-2v4h-4v2h4v4h2V6h4V4h-4zM6 34v-4H4v4H0v2h4v4h2v-4h4v-2H6zM6 4V0H4v4H0v2h4v4h2V6h4V4H6z'\/%3E%3C\/g%3E%3C\/g%3E%3C\/svg%3E\");\n}\n.hero-content { position: relative; z-index: 1; max-width: 800px; margin: 0 auto; }\n.hero-badge {\n display: inline-block; padding: 6px 20px; border-radius: 20px;\n background: rgba(255,255,255,0.15); backdrop-filter: blur(8px);\n font-size: 14px; margin-bottom: 20px; border: 1px solid rgba(255,255,255,0.2);\n}\n.hero h1 { font-size: clamp(28px, 5vw, 42px); font-weight: 800; margin-bottom: 16px; line-height: 1.3; }\n.hero p { font-size: 16px; opacity: 0.9; margin-bottom: 32px; max-width: 600px; margin-left: auto; margin-right: auto; }\n.hero-tags { display: flex; gap: 12px; justify-content: center; flex-wrap: wrap; }\n.hero-tag {\n display: flex; align-items: center; gap: 6px; padding: 8px 16px;\n background: rgba(255,255,255,0.12); border-radius: 8px; font-size: 14px;\n}\n.hero-tag .icon { font-size: 18px; }<\/p>\n<p>\/* ===== Section Base ===== *\/\n.section {\n max-width: 1200px; margin: 0 auto;\n padding: 60px 20px;\n}\n.section-header {\n text-align: center; margin-bottom: 48px;\n}\n.section-header .num {\n display: inline-flex; align-items: center; justify-content: center;\n width: 36px; height: 36px; border-radius: 50%;\n background: var(--lm-red); color: #fff; font-size: 16px; font-weight: 700;\n margin-bottom: 12px;\n}\n.section-header h2 {\n font-size: clamp(24px, 4vw, 32px); font-weight: 800; color: var(--lm-gray-900);\n margin-bottom: 8px;\n}\n.section-header .subtitle {\n font-size: 15px; color: var(--lm-gray-600); max-width: 600px; margin: 0 auto;\n}\n.section-divider {\n width: 48px; height: 3px; background: var(--lm-red);\n margin: 16px auto 0; border-radius: 2px;\n}<\/p>\n<p>\/* ===== Module 1: Needs Analysis ===== *\/\n.needs-grid {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n gap: 20px;\n}\n.need-card {\n background: #fff; border-radius: var(--lm-radius); padding: 28px;\n box-shadow: var(--lm-shadow); transition: var(--lm-transition);\n border: 1px solid var(--lm-gray-200); position: relative; overflow: hidden;\n}\n.need-card:hover {\n transform: translateY(-4px); box-shadow: var(--lm-shadow-lg);\n border-color: var(--lm-red-light);\n}\n.need-card::before {\n content: ''; position: absolute; top: 0; left: 0; right: 0; height: 3px;\n background: linear-gradient(90deg, var(--lm-red), var(--lm-red-light));\n}\n.need-icon { font-size: 36px; margin-bottom: 16px; }\n.need-card h3 { font-size: 18px; font-weight: 700; margin-bottom: 10px; }\n.need-card p { font-size: 14px; color: var(--lm-gray-600); line-height: 1.8; }\n.need-card .pain { color: var(--lm-red); font-weight: 600; }<\/p>\n<p>\/* ===== Module 2: Product Specs ===== *\/\n.product-section { margin-bottom: 40px; }\n.product-section h3 {\n font-size: 20px; font-weight: 700; margin-bottom: 20px;\n display: flex; align-items: center; gap: 10px;\n}\n.product-section h3 .badge {\n font-size: 12px; padding: 2px 10px; border-radius: 10px;\n background: var(--lm-red); color: #fff; font-weight: 600;\n}<\/p>\n<p>\/* Image Slider *\/\n.slider-container {\n position: relative; border-radius: var(--lm-radius);\n overflow: hidden; background: #000; margin-bottom: 24px;\n}\n.slider-track {\n display: flex; transition: transform 0.5s cubic-bezier(0.4,0,0.2,1);\n}\n.slider-track img {\n width: 100%; flex-shrink: 0; object-fit: contain;\n max-height: 400px; background: #f8f8f8;\n}\n.slider-btn {\n position: absolute; top: 50%; transform: translateY(-50%);\n width: 44px; height: 44px; border-radius: 50%; border: none;\n background: rgba(255,255,255,0.9); color: var(--lm-gray-900);\n font-size: 20px; cursor: pointer; transition: var(--lm-transition);\n display: flex; align-items: center; justify-content: center;\n box-shadow: var(--lm-shadow); z-index: 2;\n}\n.slider-btn:hover { background: #fff; box-shadow: var(--lm-shadow-lg); }\n.slider-btn.prev { left: 12px; }\n.slider-btn.next { right: 12px; }\n.slider-dots {\n position: absolute; bottom: 12px; left: 50%; transform: translateX(-50%);\n display: flex; gap: 8px; z-index: 2;\n}\n.slider-dot {\n width: 8px; height: 8px; border-radius: 50%;\n background: rgba(255,255,255,0.5); cursor: pointer; border: none;\n transition: var(--lm-transition);\n}\n.slider-dot.active { background: #fff; width: 24px; border-radius: 4px; }<\/p>\n<p>\/* Spec Table *\/\n.spec-table-wrap {\n overflow-x: auto; border-radius: var(--lm-radius);\n box-shadow: var(--lm-shadow); margin-bottom: 24px;\n}\n.spec-table {\n width: 100%; border-collapse: collapse; font-size: 14px;\n background: #fff;\n}\n.spec-table th, .spec-table td {\n padding: 12px 16px; text-align: left; border-bottom: 1px solid var(--lm-gray-200);\n}\n.spec-table th {\n background: var(--lm-gray-100); font-weight: 600; white-space: nowrap;\n color: var(--lm-gray-800); font-size: 13px;\n}\n.spec-table tr:hover { background: rgba(198,40,40,0.02); }\n.spec-table .highlight { color: var(--lm-red); font-weight: 600; }\n.spec-table .label-col { width: 120px; color: var(--lm-gray-600); }<\/p>\n<p>\/* Product Link Button *\/\n.product-link {\n display: inline-flex; align-items: center; gap: 6px;\n padding: 10px 24px; border-radius: 8px; font-size: 14px; font-weight: 600;\n text-decoration: none; transition: var(--lm-transition);\n border: 2px solid var(--lm-red); color: var(--lm-red);\n}\n.product-link:hover {\n background: var(--lm-red); color: #fff;\n}<\/p>\n<p>\/* ===== Module 3: Solutions ===== *\/\n.solution-cards {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr));\n gap: 24px; margin-bottom: 32px;\n}\n.sol-card {\n background: #fff; border-radius: var(--lm-radius); overflow: hidden;\n box-shadow: var(--lm-shadow); border: 2px solid transparent;\n transition: var(--lm-transition); position: relative;\n}\n.sol-card:hover { box-shadow: var(--lm-shadow-lg); transform: translateY(-4px); }\n.sol-card.recommended { border-color: var(--lm-red); }\n.sol-card .rec-badge {\n position: absolute; top: 16px; right: -32px;\n background: var(--lm-red); color: #fff; font-size: 12px; font-weight: 700;\n padding: 4px 40px; transform: rotate(45deg);\n}\n.sol-card-header {\n padding: 24px 24px 16px; border-bottom: 1px solid var(--lm-gray-200);\n}\n.sol-card-header .brand { font-size: 12px; color: var(--lm-gray-600); text-transform: uppercase; letter-spacing: 1px; }\n.sol-card-header h4 { font-size: 20px; font-weight: 800; margin: 6px 0; }\n.sol-card-header .model { font-size: 13px; color: var(--lm-gray-600); font-family: monospace; }\n.sol-card-body { padding: 20px 24px; }\n.sol-feature {\n display: flex; align-items: flex-start; gap: 10px;\n padding: 8px 0; font-size: 14px;\n}\n.sol-feature .dot {\n width: 6px; height: 6px; border-radius: 50%; background: var(--lm-red);\n flex-shrink: 0; margin-top: 8px;\n}\n.sol-card-footer {\n padding: 16px 24px 24px; border-top: 1px solid var(--lm-gray-200);\n}\n.sol-price { font-size: 28px; font-weight: 800; color: var(--lm-red); }\n.sol-price small { font-size: 14px; font-weight: 400; color: var(--lm-gray-600); }\n.sol-price-note { font-size: 12px; color: var(--lm-gray-600); margin-top: 4px; }\n.sol-link {\n display: block; margin-top: 12px; padding: 10px; text-align: center;\n border-radius: 8px; font-size: 14px; font-weight: 600;\n text-decoration: none; transition: var(--lm-transition);\n border: 1.5px solid var(--lm-gray-300); color: var(--lm-gray-800);\n}\n.sol-link:hover { border-color: var(--lm-red); color: var(--lm-red); }<\/p>\n<p>\/* Design Note *\/\n.design-note {\n background: linear-gradient(135deg, #FFF8E1, #FFF3E0);\n border-radius: var(--lm-radius); padding: 20px 24px;\n border-left: 4px solid var(--lm-gold);\n font-size: 14px; line-height: 1.8; color: var(--lm-gray-800);\n}\n.design-note strong { color: var(--lm-red); }<\/p>\n<p>\/* ===== Module 4: Pricing ===== *\/\n.price-summary {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n gap: 20px; margin-bottom: 32px;\n}\n.price-card {\n background: #fff; border-radius: var(--lm-radius); padding: 24px;\n box-shadow: var(--lm-shadow); text-align: center;\n border: 2px solid var(--lm-gray-200); transition: var(--lm-transition);\n}\n.price-card:hover { border-color: var(--lm-red-light); }\n.price-card.best { border-color: var(--lm-red); background: linear-gradient(135deg, #FFF8F8, #fff); }\n.price-card .label { font-size: 14px; color: var(--lm-gray-600); margin-bottom: 8px; }\n.price-card .name { font-size: 18px; font-weight: 700; margin-bottom: 12px; }\n.price-card .amount {\n font-size: 36px; font-weight: 800; color: var(--lm-red);\n}\n.price-card .amount small { font-size: 16px; }\n.price-card .breakdown {\n margin-top: 16px; text-align: left; font-size: 13px; color: var(--lm-gray-600);\n}\n.price-card .breakdown div {\n display: flex; justify-content: space-between; padding: 4px 0;\n border-bottom: 1px dashed var(--lm-gray-200);\n}<\/p>\n<p>\/* Benefits *\/\n.benefits-grid {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n gap: 16px; margin-bottom: 24px;\n}\n.benefit-item {\n display: flex; align-items: flex-start; gap: 12px;\n padding: 16px; background: #fff; border-radius: var(--lm-radius-sm);\n box-shadow: 0 1px 4px rgba(0,0,0,0.06);\n}\n.benefit-icon {\n width: 40px; height: 40px; border-radius: 10px;\n display: flex; align-items: center; justify-content: center;\n font-size: 20px; flex-shrink: 0;\n}\n.benefit-item h4 { font-size: 14px; font-weight: 700; margin-bottom: 4px; }\n.benefit-item p { font-size: 12px; color: var(--lm-gray-600); }<\/p>\n<p>\/* Price Disclaimer *\/\n.price-disclaimer {\n background: var(--lm-gray-100); border-radius: var(--lm-radius-sm);\n padding: 16px 20px; font-size: 13px; color: var(--lm-gray-600);\n line-height: 1.8;\n}<\/p>\n<p>\/* ===== Module 5: Construction & Warranty ===== *\/\n.construction-flow {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n gap: 16px; margin-bottom: 40px;\n}\n.flow-step {\n text-align: center; padding: 24px 16px;\n background: #fff; border-radius: var(--lm-radius);\n box-shadow: var(--lm-shadow); position: relative;\n}\n.flow-step .step-num {\n width: 32px; height: 32px; border-radius: 50%;\n background: var(--lm-red); color: #fff; font-weight: 700;\n display: inline-flex; align-items: center; justify-content: center;\n font-size: 14px; margin-bottom: 12px;\n}\n.flow-step h4 { font-size: 15px; font-weight: 700; margin-bottom: 6px; }\n.flow-step p { font-size: 13px; color: var(--lm-gray-600); }\n.flow-arrow {\n position: absolute; right: -14px; top: 50%; transform: translateY(-50%);\n font-size: 20px; color: var(--lm-gray-300);\n}<\/p>\n<p>\/* Installation Slider (same as product slider) *\/\n.install-slider-section { margin-bottom: 40px; }<\/p>\n<p>\/* Warranty Cards *\/\n.warranty-grid {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr));\n gap: 16px; margin-bottom: 40px;\n}\n.warranty-card {\n padding: 24px; background: #fff; border-radius: var(--lm-radius);\n box-shadow: var(--lm-shadow); text-align: center;\n border-top: 3px solid var(--lm-red);\n}\n.warranty-card .w-icon { font-size: 32px; margin-bottom: 12px; }\n.warranty-card h4 { font-size: 16px; font-weight: 700; margin-bottom: 8px; }\n.warranty-card .w-year { font-size: 28px; font-weight: 800; color: var(--lm-red); }\n.warranty-card .w-year small { font-size: 14px; font-weight: 400; }\n.warranty-card p { font-size: 13px; color: var(--lm-gray-600); margin-top: 8px; }<\/p>\n<p>\/* Auth\/Cert Images *\/\n.cert-grid {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n gap: 16px;\n}\n.cert-item {\n background: #fff; border-radius: var(--lm-radius-sm); overflow: hidden;\n box-shadow: var(--lm-shadow); transition: var(--lm-transition);\n}\n.cert-item:hover { transform: translateY(-2px); box-shadow: var(--lm-shadow-lg); }\n.cert-item img { width: 100%; height: 200px; object-fit: cover; }\n.cert-item .cert-label {\n padding: 10px 14px; font-size: 13px; font-weight: 600;\n text-align: center; color: var(--lm-gray-800);\n}<\/p>\n<p>\/* ===== Module 6: Cases ===== *\/\n.case-cards {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr));\n gap: 20px;\n}\n.case-card {\n background: #fff; border-radius: var(--lm-radius); overflow: hidden;\n box-shadow: var(--lm-shadow); transition: var(--lm-transition);\n}\n.case-card:hover { transform: translateY(-4px); box-shadow: var(--lm-shadow-lg); }\n.case-card .case-header {\n padding: 20px 24px; background: linear-gradient(135deg, var(--lm-red-dark), var(--lm-red));\n color: #fff;\n}\n.case-card .case-header h4 { font-size: 16px; font-weight: 700; }\n.case-card .case-header .case-loc { font-size: 13px; opacity: 0.85; margin-top: 4px; }\n.case-card .case-body { padding: 20px 24px; }\n.case-card .case-stat {\n display: flex; justify-content: space-between; padding: 8px 0;\n border-bottom: 1px dashed var(--lm-gray-200); font-size: 14px;\n}\n.case-card .case-stat .val { font-weight: 700; color: var(--lm-red); }<\/p>\n<p>\/* ===== Boiler Principle Section ===== *\/\n.boiler-section {\n max-width: 1200px; margin: 0 auto; padding: 40px 20px 60px;\n}\n.boiler-section .section-header { margin-bottom: 24px; }\n.accordion-trigger {\n width: 100%; padding: 16px 24px; border: 2px solid var(--lm-gray-300);\n border-radius: var(--lm-radius-sm); background: #fff; cursor: pointer;\n display: flex; align-items: center; justify-content: space-between;\n font-size: 16px; font-weight: 700; transition: var(--lm-transition);\n font-family: inherit; color: var(--lm-gray-900);\n}\n.accordion-trigger:hover { border-color: var(--lm-red); color: var(--lm-red); }\n.accordion-trigger .arrow { transition: transform 0.3s; font-size: 14px; }\n.accordion-trigger.open { border-color: var(--lm-red); color: var(--lm-red); border-radius: var(--lm-radius-sm) var(--lm-radius-sm) 0 0; }\n.accordion-trigger.open .arrow { transform: rotate(180deg); }\n.accordion-content {\n max-height: 0; overflow: hidden; transition: max-height 0.5s cubic-bezier(0.4,0,0.2,1);\n border: 2px solid transparent; border-top: none;\n border-radius: 0 0 var(--lm-radius-sm) var(--lm-radius-sm);\n}\n.accordion-content.open {\n max-height: 3000px; border-color: var(--lm-red);\n}<\/p>\n<p>\/* ===== Footer ===== *\/\n.page-footer {\n background: var(--lm-gray-900); color: #fff;\n padding: 40px 20px; text-align: center;\n}\n.page-footer h3 { font-size: 20px; margin-bottom: 8px; }\n.page-footer p { font-size: 14px; opacity: 0.7; margin-bottom: 4px; }<\/p>\n<p>\/* ===== Scroll Animations ===== *\/\n.fade-in {\n opacity: 0; transform: translateY(30px);\n transition: opacity 0.6s, transform 0.6s;\n}\n.fade-in.visible { opacity: 1; transform: translateY(0); }<\/p>\n<p>\/* ===== Responsive ===== *\/\n@media (max-width: 768px) {\n .section { padding: 40px 16px; }\n .hero { padding: 110px 16px 40px; }\n .hero h1 { font-size: 24px; }\n .hero-tags { gap: 8px; }\n .hero-tag { padding: 6px 12px; font-size: 12px; }\n .needs-grid { grid-template-columns: 1fr; }\n .solution-cards { grid-template-columns: 1fr; }\n .price-summary { grid-template-columns: 1fr; }\n .construction-flow { grid-template-columns: repeat(2, 1fr); }\n .flow-arrow { display: none; }\n .nav-link { padding: 6px 10px; font-size: 12px; }\n .cert-grid { grid-template-columns: repeat(2, 1fr); }\n .case-cards { grid-template-columns: 1fr; }\n}\n\/* ===== Calculator ===== *\/\n.calc-section {\n background: linear-gradient(135deg, #f8fafc, #eef2ff);\n border-radius: var(--lm-radius);\n padding: 32px 24px;\n margin-top: 40px;\n box-shadow: var(--lm-shadow);\n}\n.calc-form {\n display: grid;\n grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n gap: 20px;\n margin-bottom: 28px;\n}\n.calc-field { display: flex; flex-direction: column; gap: 6px; }\n.calc-field label {\n font-size: 14px; font-weight: 600; color: var(--lm-gray-800);\n}\n.calc-field select, .calc-field input {\n padding: 10px 14px; border: 2px solid var(--lm-gray-300);\n border-radius: 8px; font-size: 15px; font-family: inherit;\n background: #fff; color: var(--lm-gray-900);\n transition: var(--lm-transition);\n}\n.calc-field select:focus, .calc-field input:focus {\n outline: none; border-color: var(--lm-red); box-shadow: 0 0 0 3px rgba(198,40,40,0.1);\n}\n.calc-result {\n background: #fff; border-radius: var(--lm-radius);\n padding: 28px; box-shadow: var(--lm-shadow);\n border: 2px solid var(--lm-red);\n}\n.calc-result .result-header {\n display: flex; align-items: center; justify-content: space-between;\n margin-bottom: 20px; flex-wrap: wrap; gap: 12px;\n}\n.calc-result .result-title { font-size: 18px; font-weight: 700; }\n.calc-result .result-total {\n font-size: 36px; font-weight: 800; color: var(--lm-red);\n}\n.calc-result .result-total small { font-size: 16px; font-weight: 400; color: var(--lm-gray-600); }\n.calc-breakdown { font-size: 14px; color: var(--lm-gray-600); }\n.calc-breakdown .bd-row {\n display: flex; justify-content: space-between; padding: 8px 0;\n border-bottom: 1px dashed var(--lm-gray-200);\n}\n.calc-breakdown .bd-row.bd-total { border-bottom: none; font-weight: 700; color: var(--lm-gray-900); font-size: 15px; }\n.calc-btn {\n display: inline-flex; align-items: center; gap: 6px;\n padding: 12px 32px; border-radius: 8px; font-size: 16px; font-weight: 700;\n background: var(--lm-red); color: #fff; border: none; cursor: pointer;\n transition: var(--lm-transition); font-family: inherit;\n}\n.calc-btn:hover { background: var(--lm-red-dark); transform: translateY(-2px); }\n.calc-note { font-size: 12px; color: var(--lm-gray-600); margin-top: 16px; line-height: 1.8; }<\/p>\n<p>\/* \u5730\u6696\u6a21\u5f0f\u5361\u7247 *\/\n.heating-mode-cards {\n display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr));\n gap: 24px; margin-top: 24px;\n}\n.mode-card {\n background: #fff; border-radius: var(--lm-radius); overflow: hidden;\n box-shadow: var(--lm-shadow); border: 2px solid transparent;\n transition: var(--lm-transition); position: relative;\n}\n.mode-card:hover { box-shadow: var(--lm-shadow-lg); transform: translateY(-4px); }\n.mode-card.recommended { border-color: var(--lm-gold); }\n.mode-card .rec-badge {\n position: absolute; top: 16px; right: -32px;\n background: var(--lm-gold); color: #fff; font-size: 12px; font-weight: 700;\n padding: 4px 40px; transform: rotate(45deg);\n}\n.mode-card-header {\n padding: 24px 24px 16px; border-bottom: 1px solid var(--lm-gray-200);\n}\n.mode-card-header .mode-tag { font-size: 12px; color: var(--lm-gray-600); text-transform: uppercase; letter-spacing: 1px; }\n.mode-card-header h4 { font-size: 20px; font-weight: 800; margin: 6px 0; }\n.mode-card-header .mode-sub { font-size: 13px; color: var(--lm-gray-600); }\n.mode-card-body { padding: 20px 24px; }\n.mode-feature {\n display: flex; align-items: flex-start; gap: 10px;\n padding: 8px 0; font-size: 14px;\n}\n.mode-feature .dot {\n width: 6px; height: 6px; border-radius: 50%; background: var(--lm-gold);\n flex-shrink: 0; margin-top: 8px;\n}\n.mode-card-footer {\n padding: 16px 24px 24px; border-top: 1px solid var(--lm-gray-200);\n}\n.mode-price { font-size: 28px; font-weight: 800; color: var(--lm-red); }\n.mode-price small { font-size: 14px; font-weight: 400; color: var(--lm-gray-600); }\n.mode-price-note { font-size: 12px; color: var(--lm-gray-600); margin-top: 4px; }<\/p>\n<p>@media (max-width: 768px) {\n .heating-mode-cards { grid-template-columns: 1fr; }\n .calc-form { grid-template-columns: 1fr; }\n}\n<\/style>\n<p><!-- ===== Sticky Navigation ===== --><\/p>\n<nav class=\"sticky-nav\" id=\"stickyNav\">\n<div class=\"nav-inner\">\n <a href=\"#\" class=\"nav-brand\">\ud83d\udd25 \u9f99\u8109\u6696\u901a\u00b7\u56e2\u8d2d<\/a><\/p>\n<div class=\"nav-links\">\n <a class=\"nav-link active\" href=\"#needs\" data-section=\"needs\">\u9700\u6c42\u5206\u6790<\/a><br \/>\n <a class=\"nav-link\" href=\"#products\" data-section=\"products\">\u4ea7\u54c1\u53c2\u6570<\/a><br \/>\n <a class=\"nav-link\" href=\"#solutions\" data-section=\"solutions\">\u89e3\u51b3\u65b9\u6848<\/a><br \/>\n <a class=\"nav-link\" href=\"#pricing\" data-section=\"pricing\">\u62a5\u4ef7\u56e2\u8d2d<\/a><br \/>\n <a class=\"nav-link\" href=\"#heating-modes\" data-section=\"heating-modes\">\u5730\u6696\u6a21\u5f0f<\/a><br \/>\n <a class=\"nav-link\" href=\"#calculator\" data-section=\"calculator\">\u62a5\u4ef7\u8ba1\u7b97<\/a><br \/>\n <a class=\"nav-link\" href=\"#construction\" data-section=\"construction\">\u65bd\u5de5\u4fdd\u969c<\/a><br \/>\n <a class=\"nav-link\" href=\"#cases\" data-section=\"cases\">\u6848\u4f8b\u5206\u4eab<\/a>\n <\/div>\n<\/p>\n<\/div>\n<\/nav>\n<p><!-- ===== Hero ===== --><\/p>\n<section class=\"hero\">\n<div class=\"hero-content\">\n<div class=\"hero-badge\">\ud83c\udfe0 \u5149\u534e\u5929\u73ba \u00b7 618\u56e2\u8d2d\u4e13\u4eab<\/div>\n<h2>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696<a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b<\/a><br \/>\u56e2\u8d2d\u4e13\u4eab\u5957\u9910<\/h2>\n<p>99m\u00b2\u5bb6\u5ead\u4e13\u5c5e\u65b9\u6848 | \u4e09\u79cd\u9505\u7089\u81ea\u7531\u9009 | 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/p>\n<div class=\"hero-tags\">\n<div class=\"hero-tag\"><span class=\"icon\">\ud83c\udfed<\/span>\u65e5\u7acb\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/div>\n<div class=\"hero-tag\"><span class=\"icon\">\ud83d\udee1\ufe0f<\/span>10\u5e74\u8d85\u957f\u8d28\u4fdd<\/div>\n<div class=\"hero-tag\"><span class=\"icon\">\ud83d\udccb<\/span>50\u5e74\u5730\u6696\u8054\u4fdd<\/div>\n<div class=\"hero-tag\"><span class=\"icon\">\ud83d\udcb0<\/span>\u5b9a\u91d119.9\u62b5500<\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- ===== Module 1: \u9700\u6c42\u5206\u6790 ===== --><\/p>\n<section class=\"section\" id=\"needs\">\n<div class=\"section-header fade-in\">\n<div class=\"num\">1<\/div>\n<h2>\u9700\u6c42\u5206\u6790<\/h2>\n<p class=\"subtitle\">99m\u00b2\u5bb6\u5ead\u7684\u91c7\u6696\u7a7a\u8c03\u771f\u76f8\u2014\u2014\u9009\u9519\u65b9\u6848\uff0c\u540e\u60a3\u5341\u5e74<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"needs-grid\">\n<div class=\"need-card fade-in\">\n<div class=\"need-icon\">\ud83e\udd76<\/div>\n<h3>\u7a7a\u8c03\u5730\u6696\uff0c\u53ea\u80fd\u4e8c\u9009\u4e00\uff1f<\/h3>\n<p>\u4f20\u7edf\u65b9\u6848\uff1a\u88c5\u4e2d\u592e\u7a7a\u8c03\u5c31\u4e0d\u88c5\u5730\u6696\uff0c\u51ac\u5929\u9760\u7a7a\u8c03\u5439\u70ed\u98ce\u3002\u7ed3\u679c\uff1a<span class=\"pain\">\u5934\u70ed\u811a\u51b7\u3001\u76ae\u80a4\u5e72\u71e5\u3001\u7535\u8d39\u98d9\u5347<\/span>\u3002\u5730\u6696\u7684\u811a\u6696\u5934\u51c9\u8212\u9002\u611f\uff0c\u7a7a\u8c03\u6c38\u8fdc\u7ed9\u4e0d\u4e86\u3002<\/p>\n<\/p>\n<\/div>\n<div class=\"need-card fade-in\">\n<div class=\"need-icon\">\ud83d\udcb8<\/div>\n<h3>\u71c3\u6c14\u8d39\u662f\"\u65e0\u5e95\u6d1e\"\uff1f<\/h3>\n<p>\u666e\u901a\u9505\u7089\u914d\u5730\u6696\uff0c<span class=\"pain\">\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u5927\uff0c\u9891\u7e41\u542f\u505c<\/span>\uff0c\u5b9e\u9645\u7528\u6c14\u8fdc\u8d85\u9884\u671f\u300299m\u00b2\u5bb6\u5ead\u6bcf\u6708\u71c3\u6c14\u8d39\u4e0a\u5343\uff0c\u5fc3\u75bc\u5374\u65e0\u5948\u2014\u2014\u6b8a\u4e0d\u77e5\u9009\u5bf9\u70ed\u6e90\u53ef\u4ee5\u7701\u4e00\u534a\u3002<\/p>\n<\/p>\n<\/div>\n<div class=\"need-card fade-in\">\n<div class=\"need-icon\">\ud83d\udd27<\/div>\n<h3>\u88c5\u5b8c\u5c31\u4e0d\u7ba1\u4e86\uff1f<\/h3>\n<p>\u6696\u901a\u884c\u4e1a\u91cd\u9500\u552e\u8f7b\u670d\u52a1\u3002<span class=\"pain\">\u88c5\u5b8c\u627e\u4e0d\u5230\u4eba\u3001\u552e\u540e\u63a8\u8bff\u626f\u76ae<\/span>\uff0c\u51fa\u95ee\u9898\u53ea\u80fd\u81ea\u5df1\u625b\u3002\u5730\u6696\u7ba1\u57cb\u5728\u5730\u4e0b\uff0c\u51fa\u4e86\u95ee\u9898\u6bd4\u767b\u5929\u8fd8\u96be\u4fee\u2014\u2014\u5b89\u88c5\u5de5\u827a\u548c\u552e\u540e\u4fdd\u969c\u624d\u662f\u91cd\u4e2d\u4e4b\u91cd\u3002<\/p>\n<\/p>\n<\/div>\n<div class=\"need-card fade-in\">\n<div class=\"need-icon\">\ud83d\udcd0<\/div>\n<h3>\u65b9\u6848\"\u4e00\u5200\u5207\"\uff1f<\/h3>\n<p>\u4e0d\u540c\u5bb6\u5ead\u91c7\u6696\u9762\u79ef\u3001\u70ed\u6c34\u9700\u6c42\u3001\u9884\u7b97\u5404\u4e0d\u76f8\u540c\u3002<span class=\"pain\">\u4e00\u5957\u65b9\u6848\u6253\u5929\u4e0b<\/span>\uff0c\u7ed3\u679c\u5927\u9a6c\u62c9\u5c0f\u8f66\u8d39\u6c14\u3001\u5c0f\u9a6c\u62c9\u5927\u8f66\u4e0d\u70ed\u3002\u7cbe\u51c6\u5339\u914d\uff0c\u624d\u80fd\u8212\u9002\u53c8\u7701\u94b1\u3002<\/p>\n<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- ===== Module 2: \u4ea7\u54c1\u7ec4\u5408\u6027\u80fd\u53c2\u6570 ===== --><\/p>\n<section class=\"section\" id=\"products\">\n<div class=\"section-header fade-in\">\n<div class=\"num\">2<\/div>\n<h2>\u4ea7\u54c1\u7ec4\u5408 \u00b7 \u6027\u80fd\u53c2\u6570<\/h2>\n<p class=\"subtitle\">\u65e5\u7acb\u53cc\u8f6c\u5b50\u538b\u7f29\u673a + \u4e09\u6b3e\u9505\u7089 + \u4f1f\u661f\u5730\u6696\u7cfb\u7edf\uff0c\u6bcf\u4e2a\u7ec4\u4ef6\u90fd\u7ecf\u5f97\u8d77\u63a8\u6572<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<p> <!-- \u65e5\u7acb\u8212\u4eab --><\/p>\n<div class=\"product-section fade-in\">\n<h3>\ud83c\udf21\ufe0f \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u8212\u4eab\u7cfb\u5217 <span class=\"badge\">\u6838\u5fc3<\/span><\/h3>\n<div class=\"slider-container\" id=\"acSlider\">\n<div class=\"slider-track\" id=\"acTrack\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1.jpg\" alt=\"\u65e5\u7acb\u8212\u4eab\u5916\u673a-1\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2.jpg\" alt=\"\u65e5\u7acb\u8212\u4eab\u5916\u673a-2\" loading=\"lazy\">\n <\/div>\n<p> <button class=\"slider-btn prev\" onclick=\"slidePrev('ac')\">\u2039<\/button><br \/>\n <button class=\"slider-btn next\" onclick=\"slideNext('ac')\">\u203a<\/button><\/p>\n<div class=\"slider-dots\" id=\"acDots\"><\/div>\n<\/p>\n<\/div>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<tbody>\n<tr>\n<td class=\"label-col\">\u538b\u7f29\u673a<\/td>\n<td>\u65e5\u7acb\u53cc\u8f6c\u5b50\u538b\u7f29\u673a \u00b7 \u65e5\u672c\u539f\u88c5\u6838\u5fc3\u6280\u672f<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u5916\u673a\u578b\u53f7<\/td>\n<td>RAS-125HRNAQ \u00b7 12.5kW<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u5185\u673a\u603b\u51b7\u91cf<\/td>\n<td>14.7kW\uff08\u56db\u53f0\u5185\u673a\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8d85\u914d\u7387<\/td>\n<td>117% <small style=\"color:var(--lm-gray-600)\">\uff08\u5408\u7406\u533a\u95f450%-130%\uff0c99m\u00b2\u65e5\u5e38\u4f7f\u7528\u7ef0\u7ef0\u6709\u4f59\uff09<\/small><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u53d8\u9891\u6280\u672f<\/td>\n<td>\u5168\u76f4\u6d41\u53d8\u9891 <span class=\"highlight\">APF\u80fd\u6548\u6700\u9ad86.1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8fd0\u884c\u8303\u56f4<\/td>\n<td>-21\u2103 ~ 59\u2103\u5bbd\u57df\u8fd0\u884c<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9759\u97f3<\/td>\n<td><span class=\"highlight\">17dB\u8d85\u4f4e\u9759\u97f3<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u63a7\u5236\u5668<\/td>\n<td>\u6807\u914d\u65e5\u7acb\u7ebf\u63a7\u5668 \u00b7 \u53ef\u52a0\u88c5WiFi\u8fdc\u7a0b\u63a7\u5236<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8d28\u4fdd<\/td>\n<td>\u6574\u673a66\u4e2a\u6708 + \u8212\u4eab\u5ef6\u4fdd\u5361 \u2192 <span class=\"highlight\">10\u5e74\u8d28\u4fdd<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p> <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u67e5\u770b\u65e5\u7acb\u8212\u4eab\u5b8c\u6574\u4ea7\u54c1\u624b\u518c \u2192<\/a>\n <\/div>\n<p> <!-- \u8212\u4eab\u53cc\u98ce\u6247 \u00b7 \u5168\u7cfb\u5217 --><\/p>\n<div class=\"fade-in\" style=\"margin-top:36px;\">\n<h4 style=\"font-size:16px;font-weight:700;margin-bottom:16px;color:var(--lm-blue);\">\ud83c\udf00 \u8212\u4eab\u53cc\u98ce\u6247\u7cfb\u5217\uff08\u53ef\u9009\u5347\u7ea7\uff09<\/h4>\n<div class=\"sol-feature\" style=\"margin-bottom:8px;\">\n <span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><br \/>\n <span>\u53cc\u98ce\u6247\u6563\u70ed \u00b7 \u6bd4\u5355\u98ce\u6247\u6392\u98ce\u91cf\u5927\u5e45\u63d0\u5347 \u00b7 \u53cd\u8f6c\u9664\u5c18\u81ea\u6e05\u6d01 \u00b7 \u5236\u70ed\u4f4e\u81f3-23\u2103<\/span>\n <\/div>\n<div class=\"sol-feature\" style=\"margin-bottom:16px;\">\n <span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><br \/>\n <span>\u9002\u5408\u4e2d\u5927\u6237\u578b\uff08100-200\u33a1\uff09\u00b7 \u9ad8\u6e29\u5236\u51b7\u4e0d\u964d\u9891 \u00b7 \u4e25\u5bd2\u5730\u533a\u5236\u70ed\u66f4\u5f3a<\/span>\n <\/div>\n<p> <!-- \u53cc\u98ce\u6247\u5916\u673a\u56fe\u7247 --><\/p>\n<div class=\"slider-container\" id=\"dualFanSlider\" style=\"margin-bottom:20px;\">\n<div class=\"slider-track\" id=\"dualFanTrack\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg\" alt=\"\u8212\u4eab\u53cc\u98ce\u6247\u5916\u673a-1\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-08.jpeg\" alt=\"\u8212\u4eab\u53cc\u98ce\u6247\u5916\u673a-2\" loading=\"lazy\">\n <\/div>\n<p> <button class=\"slider-btn prev\" onclick=\"slidePrev(&quot;dualFan&quot;)\">\u2039<\/button><br \/>\n <button class=\"slider-btn next\" onclick=\"slideNext(&quot;dualFan&quot;)\">\u203a<\/button><\/p>\n<div class=\"slider-dots\" id=\"dualFanDots\"><\/div>\n<\/p>\n<\/div>\n<p> <!-- \u6807\u51c6\u53cc\u98ce\u6247 125-160 --><\/p>\n<h5 style=\"font-size:14px;font-weight:700;margin-bottom:12px;color:var(--lm-gray-800);\">\ud83d\udcd0 \u6807\u51c6\u53cc\u98ce\u6247 \u00b7 125-160\u578b<\/h5>\n<div class=\"spec-table-wrap\" style=\"margin-bottom:16px;\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th>\u578b\u53f7<\/th>\n<th>\u5236\u51b7\u91cf (kW)<\/th>\n<th>\u5236\u70ed\u91cf (kW)<\/th>\n<th>APF<\/th>\n<th>\u5916\u5f62\u5c3a\u5bf8 H\u00d7W\u00d7D (mm)<\/th>\n<th>\u566a\u97f3 dB(A)<\/th>\n<th>\u51c0\u91cd (kg)<\/th>\n<th>\u6700\u591a\u5185\u673a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">RAS-125HRNBQ<\/td>\n<td>12.5<\/td>\n<td>14.0<\/td>\n<td class=\"highlight\">6.10<\/td>\n<td>1380\u00d7950\u00d7320<\/td>\n<td>52<\/td>\n<td>106<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">RAS-140HRNBQ<\/td>\n<td>14.0<\/td>\n<td>16.0<\/td>\n<td>5.85<\/td>\n<td>1380\u00d7950\u00d7320<\/td>\n<td>52<\/td>\n<td>106<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">RAS-160HRNBQ<\/td>\n<td>15.5<\/td>\n<td>18.0<\/td>\n<td>5.60<\/td>\n<td>1380\u00d7950\u00d7320<\/td>\n<td>53<\/td>\n<td>106<\/td>\n<td>7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"sol-feature\" style=\"margin-bottom:8px;\">\n <span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><br \/>\n <span><strong>\u53cd\u8f6c\u9664\u5c18\u6280\u672f\uff1a<\/strong>\u5173\u673a\u540e\u5916\u673a\u7535\u673a\u53cd\u8f6c\u8fd0\u884c\uff0c\u5f3a\u529b\u53cd\u5411\u6c14\u6d41\u5439\u51fa\u7fc5\u7247\u79ef\u5c18\/\u67f3\u7d6e\uff0c\u7ef4\u6301\u9ad8\u6548\u6362\u70ed\uff0c\u5ef6\u957f\u6574\u673a\u5bff\u547d<\/span>\n <\/div>\n<div class=\"sol-feature\" style=\"margin-bottom:20px;\">\n <span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><br \/>\n <span><strong>\u66f4\u5f3a\u5236\u70ed\uff1a<\/strong>\u5236\u70ed\u8fd0\u884c\u4e0b\u9650 -23\u2103(WB)\uff0c\u6bd4\u5355\u98ce\u6247 -21\u2103 \u66f4\u4f4e\uff0c\u9002\u5408\u4e1c\u5317\/\u897f\u5317\u7b49\u5bd2\u51b7\u5730\u533a<\/span>\n <\/div>\n<p> <!-- \u5927\u5bb9\u91cf\u53cc\u98ce\u6247 180-224 --><\/p>\n<h5 style=\"font-size:14px;font-weight:700;margin-bottom:12px;color:var(--lm-gray-800);\">\ud83d\udcd0 \u5927\u5bb9\u91cf\u578b \u00b7 180-224\u578b\uff08\u5927\u5e73\u5c42\/\u522b\u5885\u4e13\u5c5e\uff09<\/h5>\n<div class=\"spec-table-wrap\" style=\"margin-bottom:16px;\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th>\u578b\u53f7<\/th>\n<th>\u5236\u51b7\/\u5236\u70ed\u91cf (kW)<\/th>\n<th>\u9002\u7528\u9762\u79ef<\/th>\n<th>\u6700\u591a\u5185\u673a<\/th>\n<th>\u5178\u578b\u6237\u578b<\/th>\n<th>\u5907\u6ce8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">RAS-180HRNBQ<\/td>\n<td>18.0 \/ 20.0<\/td>\n<td>140~170\u33a1<\/td>\n<td>9\u53f0<\/td>\n<td>\u4e09\u5ba4\u4e24\u5385+\u53a8\u536b<\/td>\n<td>APF 5.05 \u00b7 \u6700\u5b89\u9759<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">RAS-200HRNBQ<\/td>\n<td>20.0 \/ 22.4<\/td>\n<td>160~185\u33a1<\/td>\n<td>10\u53f0<\/td>\n<td>\u56db\u5ba4\u4e24\u5385+\u53a8\u536b<\/td>\n<td>\u4e2d\u578b\u5927\u5e73\u5c42\u9996\u9009<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">RAS-224HRNBQ<\/td>\n<td>22.4 \/ 25.0<\/td>\n<td>180~200\u33a1<\/td>\n<td>12\u53f0<\/td>\n<td>\u5927\u5e73\u5c42\/\u522b\u5885<\/td>\n<td class=\"highlight\">\u4e00\u62d6\u5341\u4e8c \u00b7 \u6700\u5927\u51b7\u91cf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"design-note\" style=\"border-left-color:var(--lm-blue);margin-bottom:12px;\">\n \ud83d\udca1 <strong>\u5355\u98ce\u6247 vs \u53cc\u98ce\u6247 \u600e\u4e48\u9009\uff1a<\/strong>100\u33a1\u4ee5\u4e0b\u9009\u5355\u98ce\u6247125\u578b\u8db3\u77e3\uff1b100-150\u33a1\u63a8\u8350\u53cc\u98ce\u6247125\/140\u578b\uff0c\u6563\u70ed\u66f4\u4ece\u5bb9\u3001APF\u6700\u9ad86.10\uff1b150\u33a1\u4ee5\u4e0a\u9009160\u53cc\u98ce\u6247\u6216\u5927\u5bb9\u91cf180-224\u578b\u3002\u53cc\u98ce\u6247\u5728\u9ad8\u6e29\u5236\u51b7\u548c\u4f4e\u6e29\u5236\u70ed\u4e24\u7aef\u8868\u73b0\u5747\u4f18\u4e8e\u5355\u98ce\u6247\uff0c\u5c24\u5176\u9002\u5408\u9876\u697c\/\u897f\u6652\/\u534e\u5357\u9ad8\u6e29\/\u5317\u65b9\u4e25\u5bd2\u7b49\u6781\u7aef\u5de5\u51b5\u3002\n <\/div>\n<div style=\"display:flex;gap:12px;flex-wrap:wrap;\">\n <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u8212\u4eab\u5168\u7cfb\u4ea7\u54c1\u624b\u518c \u2192<\/a><br \/>\n <a href=\"https:\/\/longmai-nt.com\/?page_id=2782\" target=\"_blank\" class=\"product-link\">\ud83d\udcd0 \u5927\u5bb9\u91cf\u53cc\u98ce\u6247\u4e13\u9898 \u2192<\/a>\n <\/div>\n<\/p>\n<\/div>\n<p> <!-- \u65e5\u7acb\u8212\u4eab vs \u7f8e\u7684\u9886\u822a\u8005IV \u6280\u672f\u5bf9\u6bd4\uff08\u624b\u98ce\u7434\u6298\u53e0\uff09 --><\/p>\n<div class=\"boiler-section\" style=\"margin-top:20px;\">\n <button type=\"button\" class=\"accordion-trigger\" id=\"hltVsMideaTrigger\" onclick=\"toggleHltVsMidea()\"><br \/>\n <span>\u2694\ufe0f \u70b9\u51fb\u5c55\u5f00\u65e5\u7acb\u8212\u4eab vs \u7f8e\u7684\u9886\u822a\u8005\u2163 \u00b7 \u6838\u5fc3\u5dee\u5f02<\/span><br \/>\n <span class=\"arrow\">\u25bc<\/span><br \/>\n <\/button><\/p>\n<div class=\"accordion-content\" id=\"hltVsMideaContent\">\n<div class=\"fade-in\" style=\"margin-top:0;\">\n<h3 style=\"font-size:20px;font-weight:700;margin-bottom:4px;text-align:center;\">\u65e5\u7acb\u8212\u4eab vs \u7f8e\u7684\u9886\u822a\u8005\u2163 \u00b7 \u6838\u5fc3\u5dee\u5f02<\/h3>\n<p style=\"text-align:center;font-size:14px;color:var(--lm-gray-600);margin-bottom:24px;\">\u4ef7\u683c\u57fa\u672c\u6301\u5e73\uff0c\u4f46\u65e5\u7acb\u5728\u56db\u5927\u786c\u6307\u6807\u4e0a\u5168\u9762\u9886\u5148<\/p>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n<th>\ud83d\udd34 \u65e5\u7acb\u8212\u4eab<\/th>\n<th>\ud83d\udfe3 \u7f8e\u7684\u9886\u822a\u8005\u2163<\/th>\n<th>\u7ed3\u8bba<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">\u80fd\u6548\u6bd4 APF<\/td>\n<td class=\"highlight\">5.60<\/td>\n<td>4.80<\/td>\n<td>\u65e5\u7acb\u9ad817%\uff0c\u66f4\u7701\u7535<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9759\u97f3 dB(A)<\/td>\n<td class=\"highlight\">50<\/td>\n<td>54<\/td>\n<td>\u65e5\u7acb\u5b89\u9759\u8fd1\u4e00\u500d<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9632\u6f0f\u6c34<\/td>\n<td class=\"highlight\">DC\u6c34\u6cf5+\u6d6e\u5b50\u5f00\u5173\uff08\u6807\u914d\uff09<\/td>\n<td>\u9700\u989d\u5916\u9009\u914d<\/td>\n<td>\u65e5\u7acb\u6807\u914d\u53cc\u91cd\u9632\u62a4<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u81ea\u6e05\u6d01<\/td>\n<td class=\"highlight\">\u53cd\u8f6c\u9664\u5c18\uff08\u6807\u914d\uff09<\/td>\n<td>\u65e0<\/td>\n<td>\u65e5\u7acb\u514d\u7ef4\u62a4\u66f4\u6301\u4e45<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div style=\"margin-top:20px;padding:16px 20px;background:var(--lm-gray-100);border-radius:8px;font-size:13px;line-height:1.9;color:var(--lm-gray-800);\">\n \ud83c\udfc6 <strong>\u6838\u5fc3\u7ed3\u8bba\uff1a<\/strong>\u65e5\u7acb\u8212\u4eab\u5728<strong>\u80fd\u6548\u3001\u9759\u97f3\u3001\u9632\u6f0f\u6c34\u3001\u81ea\u6e05\u6d01<\/strong>\u56db\u5927\u786c\u6307\u6807\u4e0a\u5168\u9762\u9886\u5148\uff1b\u7f8e\u7684\u9886\u822a\u8005\u2163\u4ef7\u683c\u6700\u4f4e\u4f46\u54c1\u8d28\u7ec6\u8282\u8584\u5f31\u3002\u65e5\u7acb\u8212\u4eab\u662f\"\u54c1\u8d28\u6700\u4f18\u89e3\"\u2014\u2014\u548c\u7f8e\u7684\u4ef7\u683c\u6301\u5e73\u4f46\u54c1\u8d28\u8fdc\u80dc\u3002<br \/>\n \ud83d\udca7 <strong>\u9632\u6f0f\u6c34\u6740\u624b\u950f\uff1a<\/strong>\u4e2d\u592e\u7a7a\u8c03\u6f0f\u6c34\u6ce1\u540a\u9876\uff0c\u4e00\u6b21\u7ef4\u4fee\u8d395,000~20,000\u5143\u3002\u65e5\u7acb\u8212\u4eab\u5168\u7cfb\u6807\u914dDC\u6c34\u6cf5+\u6d6e\u5b50\u5f00\u5173\u53cc\u91cd\u9632\u6f0f\uff0c\u7f8e\u7684\u5747\u9700\u989d\u5916\u9009\u914d\u3002<strong>\u77013,000\u4e70\u7a7a\u8c03\uff0c\u8d545,000\u4fee\u540a\u9876\u2014\u2014\u8fd9\u7b14\u8d26\u600e\u4e48\u7b97\uff1f<\/strong>\n <\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p> <!-- \u65e5\u7acb\u5176\u4ed6\u53ef\u9009\u7cfb\u7edf --><\/p>\n<div class=\"product-section fade-in\">\n<h3>\ud83d\udd00 \u65e5\u7acb\u5176\u4ed6\u53ef\u9009\u7cfb\u7edf <span class=\"badge\" style=\"background:var(--lm-blue);\">\u53ef\u9009<\/span><\/h3>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px;margin-top:20px;\">\n <!-- \u5c0a\u777f\u5168\u6548 --><\/p>\n<div style=\"background:#fff;border-radius:var(--lm-radius);overflow:hidden;box-shadow:var(--lm-shadow);border:1px solid var(--lm-gray-200);\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg\" alt=\"\u5c0a\u777f\u5168\u6548\" style=\"width:100%;height:240px;object-fit:cover;\" loading=\"lazy\"><\/p>\n<div style=\"padding:20px;\">\n<h4 style=\"font-size:16px;font-weight:700;margin-bottom:10px;\">\u5c0a\u777f\u5168\u6548<\/h4>\n<p style=\"font-size:13px;color:var(--lm-gray-600);line-height:1.8;\">\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 \u00b7 \u8865\u6c14\u589e\u7113\u538b\u7f29\u673a \u00b7 \u53ef\u5347\u7ea7\u4e09\u8054\u4f9b \u00b7 \u53a8\u623f\/\u536b\u6d74\/\u8863\u5e3d\u95f4\u4e13\u7528\u673a\u53ef\u9009<\/p>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34 --><\/p>\n<div style=\"background:#fff;border-radius:var(--lm-radius);overflow:hidden;box-shadow:var(--lm-shadow);border:1px solid var(--lm-gray-200);\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/27d76b4b48c4b6178d44db1caeee4451.jpg\" alt=\"\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\" style=\"width:100%;height:240px;object-fit:cover;\" loading=\"lazy\"><\/p>\n<div style=\"padding:20px;\">\n<h4 style=\"font-size:16px;font-weight:700;margin-bottom:10px;\">\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34<\/h4>\n<p style=\"font-size:13px;color:var(--lm-gray-600);line-height:1.8;\">\u5929\u6c34\u5730\u6c34\u4e8c\u8054\u4f9b \u00b7 15-20\u2103\u67d4\u548c\u51fa\u98ce \u00b7 \u5730\u6696\u4e00\u4f53\u4e0d\u5e72\u71e5 \u00b7 \u4e00\u7ea7\u80fd\u6548 \u00b7 \u522b\u5885\u5927\u5e73\u5c42\u4f18\u9009<\/p>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- VAMmini II --><\/p>\n<div style=\"background:#fff;border-radius:var(--lm-radius);overflow:hidden;box-shadow:var(--lm-shadow);border:1px solid var(--lm-gray-200);\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/deda78feae006ba07372341ed4414987.jpg\" alt=\"VAMmini II\" style=\"width:100%;height:240px;object-fit:cover;\" loading=\"lazy\"><\/p>\n<div style=\"padding:20px;\">\n<h4 style=\"font-size:16px;font-weight:700;margin-bottom:10px;\">VAMmini II<\/h4>\n<p style=\"font-size:13px;color:var(--lm-gray-600);line-height:1.8;\">\u53cc\u98ce\u6247\u6da1\u65cb\u538b\u7f29\u673a \u00b7 -25\u2103~60\u2103\u7a33\u5b9a\u8fd0\u884c \u00b7 \u7d27\u51d1\u673a\u8eab \u00b7 \u4e2d\u5c0f\u6237\u578b\u6027\u4ef7\u6bd4\u4e4b\u9009<\/p>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p> <!-- \u9505\u7089\u4e09\u9009\u4e00 --><\/p>\n<div class=\"product-section fade-in\">\n<h3>\ud83d\udd25 \u58c1\u6302\u7089 \u00b7 \u4e09\u9009\u4e00<\/h3>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th>\u53c2\u6570<\/th>\n<th>\u535a\u4e16 G6100W<\/th>\n<th>\u83f2\u65af\u66fc A1JE<\/th>\n<th>\u66fc\u745e\u5fb7 HI.PRO<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">\u54c1\u724c\u4ea7\u5730<\/td>\n<td>\u5fb7\u56fd\u54c1\u724c<\/td>\n<td>\u5fb7\u56fd\u54c1\u724c<\/td>\n<td>\u56fd\u4ea7\u54c1\u724c<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u578b\u53f7<\/td>\n<td>L1P27-G6100W<\/td>\n<td>Vitopend 100-W L1P27-A1JE<\/td>\n<td>N1PB18-HI.PRO<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u989d\u5b9a\u529f\u7387<\/td>\n<td>24kW<\/td>\n<td>24kW<\/td>\n<td>18kW<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u7c7b\u578b<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089\uff08\u677f\u6362\u5f0f\uff09<\/td>\n<td><span class=\"highlight\">\u53d8\u9891\u5355\u91c7\u6696\u7089<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u6838\u5fc3\u7279\u70b9<\/td>\n<td>\u54c1\u724c\u529b\u5f3a<br \/>\u552e\u540e\u7f51\u70b9\u591a<\/td>\n<td>\u5168\u7403\u9500\u91cf\u9886\u5148<br \/>\u4e0d\u9508\u94a2\u71c3\u70e7\u5668<\/td>\n<td>\u76f4\u6d41\u53d8\u9891\u98ce\u673a<br \/>\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u4f4e<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u6362\u70ed\u65b9\u5f0f<\/td>\n<td>\u677f\u6362\u5f0f<\/td>\n<td>\u677f\u6362\u5f0f<\/td>\n<td>\u677f\u6362\u5f0f<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u63a7\u5236\u9762\u677f<\/td>\n<td>LED\u6db2\u6676\u9762\u677f<\/td>\n<td>LED\u6db2\u6676\u9762\u677f<\/td>\n<td>LED\u6db2\u6676\u9762\u677f<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9002\u914d\u5206\u6790<\/td>\n<td>\u54c1\u724c\u4fdd\u969c\uff0c\u552e\u540e\u4fbf\u5229<\/td>\n<td>\u6210\u719f\u7a33\u5b9a\uff0c\u5168\u7403\u9a8c\u8bc1<\/td>\n<td><span class=\"highlight\">18kW\u7cbe\u51c6\u5339\u914d66m\u00b2<br \/>\u51cf\u5c11\u542f\u505c\uff0c\u66f4\u8282\u80fd<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9505\u7089\u4ef7\u683c<\/td>\n<td><span class=\"highlight\">\u00a55,600<\/span><\/td>\n<td><span class=\"highlight\">\u00a55,800<\/span><\/td>\n<td><span class=\"highlight\">\u00a54,666<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u542b\u5b89\u88c5\u8fd0\u8f93<\/td>\n<td>\u2705 \u5305\u5b89\u88c5\u548c\u8fd0\u8f93<\/td>\n<td>\u2705 \u5305\u5b89\u88c5\u548c\u8fd0\u8f93<\/td>\n<td>\u2705 \u5305\u5b89\u88c5\u548c\u8fd0\u8f93<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p> <!-- \u58c1\u6302\u7089\u5916\u89c2\u56fe --><\/p>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(180px,1fr));gap:12px;margin:20px 0 24px;\">\n<div style=\"text-align:center;\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u535a\u4e16\u58c1\u6302\u7089-G6100W-1.jpg\" alt=\"\u535a\u4e16G6100W\u5916\u89c2\" style=\"width:100%;border-radius:8px;box-shadow:var(--lm-shadow);\" loading=\"lazy\"><\/p>\n<div style=\"font-size:12px;color:var(--lm-gray-600);margin-top:6px;\">\u535a\u4e16 G6100W<\/div>\n<\/p>\n<\/div>\n<div style=\"text-align:center;\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u83f2\u65af\u66fc\u58c1\u6302\u7089-B1JG-1.jpg\" alt=\"\u83f2\u65af\u66fcB1JG\u5916\u89c2\" style=\"width:100%;border-radius:8px;box-shadow:var(--lm-shadow);\" loading=\"lazy\"><\/p>\n<div style=\"font-size:12px;color:var(--lm-gray-600);margin-top:6px;\">\u83f2\u65af\u66fc B1JG<\/div>\n<\/p>\n<\/div>\n<div style=\"text-align:center;\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u66fc\u745e\u5fb7\u58c1\u6302\u7089.png\" alt=\"\u66fc\u745e\u5fb7HI.PRO\u5916\u89c2\" style=\"width:100%;border-radius:8px;box-shadow:var(--lm-shadow);\" loading=\"lazy\"><\/p>\n<div style=\"font-size:12px;color:var(--lm-gray-600);margin-top:6px;\">\u66fc\u745e\u5fb7 HI.PRO<\/div>\n<\/p>\n<\/div>\n<\/div>\n<div style=\"display:flex;gap:12px;flex-wrap:wrap;\">\n <a href=\"https:\/\/longmai-nt.com\/?p=835\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a><br \/>\n <a href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a><br \/>\n <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a>\n <\/div>\n<\/p>\n<\/div>\n<p> <!-- \u5730\u6696\u7cfb\u7edf --><\/p>\n<div class=\"product-section fade-in\">\n<h3>\u2668\ufe0f \u5730\u6696\u7cfb\u7edf \u00b7 99\u5143\/m\u00b2\u5957\u9910<\/h3>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th>\u7c7b\u522b<\/th>\n<th>\u54c1\u724c<\/th>\n<th>\u540d\u79f0\u89c4\u683c<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">\u76d8\u7ba1<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>PE-RT\u4e94\u5c42\u963b\u6c27\u5730\u6696\u7ba1 dn16\u00d72.0<\/td>\n<td>\u5730\u6696\u4e13\u7528\u8010\u70ed\u7ba1<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u4fdd\u6e29\u677f<\/td>\n<td>\u8bfa\u5c14<\/td>\n<td>\u6324\u5851\u677f 2cm<\/td>\n<td>\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u53cd\u5c04\u819c<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>\u955c\u9762\u53cd\u5c04\u819c<\/td>\n<td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u56de\u586b\u5c42<\/td>\n<td>\u6210\u90fd\u5b9a\u5236<\/td>\n<td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td>\n<td>\u84c4\u70ed\u5c42\uff0c\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u5206\u96c6\u6c34\u5668<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>\u94dc\u8d28 DN25<\/td>\n<td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\uff0c\u5206\u8def\u63a7\u5236<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u6e29\u63a7\u5668<\/td>\n<td>\u66fc\u745e\u5fb7<\/td>\n<td>RT1.23i \u00d74\u4e2a<\/td>\n<td>\u6c34\u91c7\u6696+\u8054\u52a8+WiFi<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u7535\u5b50\u6267\u884c\u5668<\/td>\n<td>\u66fc\u745e\u5fb7<\/td>\n<td>SEH35.23<\/td>\n<td>AC220V\uff0c\u63a7\u5236\u56de\u8def\u901a\u65ad<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u4e3b\u7ba1\u9053<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>F-PPR\u7ea4\u7ef4\u590d\u5408\u7ba1<\/td>\n<td>\u8010\u9ad8\u6e29\u3001\u9632\u6e17\u6c27<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9505\u7089\u63a7\u5236\u5668<\/td>\n<td>\u66fc\u745e\u5fb7<\/td>\n<td>\u2014<\/td>\n<td>\u5730\u6696\u603b\u63a7\u7cfb\u7edf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"design-note\">\n \ud83d\udca1 <strong>\u8bbe\u8ba1\u8bf4\u660e\uff1a<\/strong>66m\u00b2\u91c7\u6696\u9762\u79ef\uff0c\u6052\u6e29\u8d1f\u8377\u7ea63.3-5.3kW\u3002\u535a\u4e16G6100W\u54c1\u724c\u529b\u5f3a\u552e\u540e\u7f51\u70b9\u591a\uff1b\u83f2\u65af\u66fcA1JE\u5168\u7403\u9500\u91cf\u9886\u5148\uff1b\u66fc\u745e\u5fb7\u53d8\u9891\u708918kW\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u66f4\u4f4e\uff0c\u66f4\u5339\u914d\u5730\u6696\u4f4e\u8d1f\u8377\u8fd0\u884c\u3002\u4e09\u79cd\u65b9\u6848\u5404\u6709\u4fa7\u91cd\uff0c\u6309\u9884\u7b97\u548c\u504f\u597d\u9009\u62e9\u3002\n <\/div>\n<\/p>\n<\/div>\n<p> <!-- \u5c0a\u777f\u5168\u6548II \u00b7 \u65e5\u7acb\u9ad8\u7aef\u65b9\u6848 --><\/p>\n<div class=\"product-section fade-in\" id=\"vamII\">\n<h3>\ud83c\udf1f \u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u00b7 \u9ad8\u7aef\u4e4b\u9009 <span class=\"badge\">\u5347\u7ea7<\/span><\/h3>\n<div class=\"slider-container\" id=\"vamSlider\">\n<div class=\"slider-track\" id=\"vamTrack\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/VAM\u5c0a\u777f\u5168\u6548II01.jpg\" alt=\"\u5c0a\u777f\u5168\u6548II\u5916\u673a\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/VAM\u5c0a\u777f\u5168\u6548II02.jpg\" alt=\"\u5c0a\u777f\u5168\u6548II\u5ba4\u5185\u673a\" loading=\"lazy\">\n <\/div>\n<p> <button class=\"slider-btn prev\" onclick=\"slidePrev('vam')\">\u2039<\/button><br \/>\n <button class=\"slider-btn next\" onclick=\"slideNext('vam')\">\u203a<\/button><\/p>\n<div class=\"slider-dots\" id=\"vamDots\"><\/div>\n<\/p>\n<\/div>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<tbody>\n<tr>\n<td class=\"label-col\">\u4ea7\u54c1\u5b9a\u4f4d<\/td>\n<td>\u65e5\u7acb\u9ad8\u7aef\u65d7\u8230 \u00b7 \u5168\u6548\u578b\u4e2d\u592e\u7a7a\u8c03<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u538b\u7f29\u673a<\/td>\n<td>\u65e5\u7acb\u53cc\u8f6c\u5b50\u538b\u7f29\u673a \u00b7 \u8865\u6c14\u589e\u7113\u6280\u672f<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u80fd\u6548\u7b49\u7ea7<\/td>\n<td class=\"highlight\">APF \u6700\u9ad8 6.1 \u00b7 \u8d85\u4e00\u7ea7\u80fd\u6548<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8fd0\u884c\u8303\u56f4<\/td>\n<td>-21\u2103 ~ 59\u2103 \u5bbd\u57df\u8fd0\u884c<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9759\u97f3<\/td>\n<td class=\"highlight\">17dB \u8d85\u4f4e\u9759\u97f3\uff08\u884c\u4e1a\u5929\u82b1\u677f\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u51c0\u5316\u7cfb\u7edf<\/td>\n<td>PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff08PM2.5 94.46% \u00b7 \u7532\u919b74.9%\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u667a\u80fd\u63a7\u5236<\/td>\n<td>WiFi + \u8bed\u97f3 + \u7c73\u5bb6 + 16\u573a\u666f\u6a21\u5f0f<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9002\u7528\u573a\u666f<\/td>\n<td>\u5927\u6237\u578b\/\u522b\u5885 \u00b7 \u8ffd\u6c42\u6781\u81f4\u8212\u9002\u5ea6\u5bb6\u5ead<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8d28\u4fdd<\/td>\n<td class=\"highlight\">10\u5e74\u8d85\u957f\u8d28\u4fdd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"design-note\" style=\"border-left-color:var(--lm-gold);\">\n \ud83d\udca1 <strong>\u65b9\u6848\u8bf4\u660e\uff1a<\/strong>\u5c0a\u777f\u5168\u6548II\u662f\u65e5\u7acb\u9ad8\u7aef\u65d7\u8230\uff0c\u5728\u8212\u4eab\u7cfb\u5217\u57fa\u7840\u4e0a\u8fdb\u4e00\u6b65\u5347\u7ea7\u51c0\u5316\u7cfb\u7edf\u548c\u9759\u97f3\u8868\u73b0\uff0c\u9002\u5408\u5bf9\u7a7a\u6c14\u54c1\u8d28\u548c\u8212\u9002\u5ea6\u6709\u6781\u81f4\u8981\u6c42\u7684\u5bb6\u5ead\u3002\u914d\u5408\u5730\u6696\u7cfb\u7edf\uff0c\u5b9e\u73b0\u7a7a\u8c03\u5730\u6696\u4e00\u4f53\u5316\u9ad8\u54c1\u8d28\u65b9\u6848\u3002\n <\/div>\n<\/p>\n<\/div>\n<p> <!-- \u6c34\u5885\u9002 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b --><\/p>\n<div class=\"product-section fade-in\" id=\"suituku\">\n<h3>\ud83d\udca7 \u65e5\u7acb\u6c34\u5885\u9002 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b <span class=\"badge\" style=\"background:var(--lm-blue);\">\u4e24\u8054\u4f9b<\/span><\/h3>\n<div class=\"slider-container\" id=\"suitukuSlider\">\n<div class=\"slider-track\" id=\"suitukuTrack\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u6c34\u5885\u9002VF01.jpg\" alt=\"\u6c34\u5885\u9002\u5916\u673a\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u6c34\u5885\u9002VF02.jpg\" alt=\"\u6c34\u5885\u9002\u7cfb\u7edf\u793a\u610f\u56fe\" loading=\"lazy\">\n <\/div>\n<p> <button class=\"slider-btn prev\" onclick=\"slidePrev('suituku')\">\u2039<\/button><br \/>\n <button class=\"slider-btn next\" onclick=\"slideNext('suituku')\">\u203a<\/button><\/p>\n<div class=\"slider-dots\" id=\"suitukuDots\"><\/div>\n<\/p>\n<\/div>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<tbody>\n<tr>\n<td class=\"label-col\">\u7cfb\u7edf\u7c7b\u578b<\/td>\n<td class=\"highlight\">\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\uff08\u7a7a\u8c03+\u5730\u6696\u4e00\u5957\u4e3b\u673a\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u4e3b\u673a\u578b\u53f7<\/td>\n<td>\u65e5\u7acb\u6c34\u5885\u9002 VF\u7cfb\u5217<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u7a7a\u8c03\u672b\u7aef<\/td>\n<td>\u6c34\u7cfb\u7edf\u51fa\u98ce \u00b7 \u67d4\u548c\u4e0d\u5e72\u71e5 \u00b7 \u6e29\u5dee\u5c0f\u4f53\u611f\u8212\u9002<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u5730\u6696\u672b\u7aef<\/td>\n<td>\u6c34\u5730\u6696 \u00b7 \u811a\u6696\u5934\u51c9 \u00b7 \u84c4\u70ed\u5f0f\u6301\u7eed\u6563\u70ed<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u80fd\u6548\u4f18\u52bf<\/td>\n<td class=\"highlight\">\u5730\u6696\u8fd0\u884c\u8d39\u7528\u6bd4\u71c3\u6c14\u770140%-60%<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u9002\u7528\u573a\u666f<\/td>\n<td>\u5bb6\u6709\u8001\u4eba\/\u5c0f\u5b69 \u00b7 \u6ce8\u91cd\u957f\u671f\u8282\u80fd \u00b7 \u8ffd\u6c42\u6700\u9ad8\u8212\u9002\u5ea6<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u6838\u5fc3\u4f18\u52bf<\/td>\n<td>\u4e00\u5957\u4e3b\u673a\u89e3\u51b3\u51b7\u6696 \u00b7 \u51fa\u6c34\u6e29\u5ea6\u7cbe\u51c6\u63a7\u5236 \u00b7 \u8fd0\u884c\u6781\u9759<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8d28\u4fdd<\/td>\n<td class=\"highlight\">10\u5e74\u8d85\u957f\u8d28\u4fdd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"design-note\" style=\"border-left-color:var(--lm-blue);\">\n \ud83d\udca7 <strong>\u4e24\u8054\u4f9b\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong>\u7a7a\u8c03\u7528\u5730\u6696\u7528\uff0c\u4e00\u5957\u4e3b\u673a\u641e\u5b9a\u51b7\u6696\u3002\u6c34\u7cfb\u7edf\u7a7a\u8c03\u51fa\u98ce\u67d4\u548c\u3001\u4e0d\u5e72\u71e5\u3001\u6e29\u5dee\u5c0f\uff08\u6bd4\u6c1f\u7a7a\u8c03\u8212\u9002\u4e00\u4e2a\u6863\u6b21\uff09\uff1b\u5730\u6696\u7528\u7a7a\u6c14\u80fd\u70ed\u6cf5\u9a71\u52a8\uff0c\u8fd0\u884c\u8d39\u7528\u6bd4\u71c3\u6c14\u9505\u7089\u770140%-60%\uff0c\u957f\u671f\u770b\u6781\u5176\u5212\u7b97\u3002<br \/>\n \ud83c\udfc6 <strong>\u9002\u5408\u8c01\uff1a<\/strong>\u5c24\u5176\u9002\u5408\u5bb6\u6709\u8001\u4eba\/\u5c0f\u5b69\u3001\u6ce8\u91cd\u957f\u671f\u8282\u80fd\u3001\u8ffd\u6c42\u6700\u9ad8\u8212\u9002\u5ea6\u7684\u5bb6\u5ead\u3002\u5149\u534e\u5929\u73ba99\u33a1\u6237\u578b\u4e5f\u53ef\u9009\u914d\u6c34\u5885\u9002mini\u7cfb\u5217\uff0c\u5177\u4f53\u53ef\u54a8\u8be2\u8bbe\u8ba1\u5e08\u3002\n <\/div>\n<p> <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u67e5\u770b\u65e5\u7acb\u5168\u7cfb\u4ea7\u54c1\u624b\u518c \u2192<\/a>\n <\/div>\n<p> <!-- \u7a7a\u8c03\u8f85\u6750 --><\/p>\n<div class=\"product-section fade-in\">\n<h3>\ud83d\udd27 \u7a7a\u8c03\u5b89\u88c5\u8f85\u6750\u6e05\u5355<\/h3>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th>\u7c7b\u522b<\/th>\n<th>\u54c1\u724c<\/th>\n<th>\u540d\u79f0\u89c4\u683c<\/th>\n<th>\u529f\u80fd<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">\u94dc\u7ba1<\/td>\n<td>\u9f99\u715c<\/td>\n<td>\u7d2b\u94dc\u7ba1 6.35\/9.53\/12.7\u00d70.8mm<\/td>\n<td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u94dc\u7ba1<\/td>\n<td>\u9f99\u715c<\/td>\n<td>\u7d2b\u94dc\u7ba1 15.88\/19.05\u00d71.0mm<\/td>\n<td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u5206\u6b67\u7ba1<\/td>\n<td>\u9f99\u715c<\/td>\n<td>\u5206\u6b67\u7ba1<\/td>\n<td>\u51b7\u5a92\u5206\u914d<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u51b7\u5a92<\/td>\n<td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td>\n<td>R410A\u65b0\u51b7\u5a92<\/td>\n<td>\u73af\u4fdd\u51b7\u5a92<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u94dc\u7ba1\u4fdd\u6e29<\/td>\n<td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td>\n<td>\u4fdd\u6e29\u68c9 \u539a\u5ea615\/20mm<\/td>\n<td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u51fa\u98ce\u53e3<\/td>\n<td>\u5b9a\u5236<\/td>\n<td>ABS\u9632\u7ed3\u9732\u767e\u53f6\u51fa\u98ce\u53e3 \u00d74<\/td>\n<td>\u4fa7\u9001\u98ce\uff0c\u9632\u51dd\u9732<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u56de\u98ce\u53e3<\/td>\n<td>\u5b9a\u5236<\/td>\n<td>ABS\u9632\u7ed3\u9732\u767e\u53f6\u56de\u98ce\u53e3 \u00d74<\/td>\n<td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee\u53e3<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u7535\u6e90\u7ebf<\/td>\n<td>\u5854\u724c<\/td>\n<td>BV\u7535\u6e90\u7ebf 1\u00d72.5mm\u00b2<\/td>\n<td>\u5185\u673a\u914d\u7535<\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u901a\u8baf\u7ebf<\/td>\n<td>\u7f8e\u6cb3<\/td>\n<td>RVVP\u5c4f\u853d\u7ebf 2\u00d70.75mm\u00b2<\/td>\n<td>\u63a7\u5236\u5668\u901a\u8baf\u63a5\u7ebf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"design-note\" style=\"border-left-color: var(--lm-blue);\">\n \ud83d\udccc <strong>\u8f85\u6750\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u8f85\u6750\u5df2\u542b\u5728\u7a7a\u8c03\u5b89\u88c5\u8d39\u5185\uff0c\u5305\u5de5\u5305\u6599\u3002\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u8f85\u6750\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3001\u4e0d\u542b\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\u3002\n <\/div>\n<\/p>\n<\/div>\n<\/section>\n<p><!-- ===== Module 3: \u591a\u79cd\u53ef\u884c\u89e3\u51b3\u65b9\u6848 ===== --><\/p>\n<section class=\"section\" id=\"solutions\">\n<div class=\"section-header fade-in\">\n<div class=\"num\">3<\/div>\n<h2>\u591a\u79cd\u53ef\u884c\u89e3\u51b3\u65b9\u6848<\/h2>\n<p class=\"subtitle\">\u540c\u4e00\u5957\u65e5\u7acb\u7a7a\u8c03+\u5730\u6696\uff0c\u4e09\u79cd\u9505\u7089\u65b9\u6848\u6309\u9884\u7b97\u548c\u504f\u597d\u9009\u62e9<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"solution-cards\">\n <!-- \u5957\u9910A \u535a\u4e16 --><\/p>\n<div class=\"sol-card fade-in\">\n<div class=\"sol-card-header\">\n<div class=\"brand\">\u5957\u9910A<\/div>\n<h4>\ud83d\udd25 \u535a\u4e16 G6100W<\/h4>\n<div class=\"model\">L1P27-G6100W \u00b7 24kW\u5e38\u89c4\u4e24\u7528\u7089<\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-body\">\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u5fb7\u56fd\u54c1\u724c \u00b7 \u54c1\u724c\u529b\u5f3a\uff0c\u552e\u540e\u7f51\u70b9\u904d\u5e03<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>24kW\u989d\u5b9a\u529f\u7387 \u00b7 \u677f\u6362\u5f0f\u6362\u70ed<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>LED\u6db2\u6676\u9762\u677f \u00b7 \u64cd\u4f5c\u7b80\u4fbf<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u7d27\u51d1\u673a\u8eab \u00b7 \u5b89\u88c5\u7075\u6d3b<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u535a\u4e16\u5168\u7403\u670d\u52a1\u4f53\u7cfb \u00b7 \u5b89\u5fc3\u4e4b\u9009<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-footer\">\n<div class=\"sol-price\">\u00a55,600 <small>\/\u53f0<\/small><\/div>\n<div class=\"sol-price-note\">\u5305\u5b89\u88c5\u548c\u8fd0\u8f93<\/div>\n<p> <a href=\"https:\/\/longmai-nt.com\/?p=835\" target=\"_blank\" class=\"sol-link\">\u67e5\u770b\u535a\u4e16\u8be6\u60c5 \u2192<\/a>\n <\/div>\n<\/p>\n<\/div>\n<p> <!-- \u5957\u9910B \u83f2\u65af\u66fc --><\/p>\n<div class=\"sol-card fade-in recommended\">\n<div class=\"rec-badge\">\u70ed\u9500<\/div>\n<div class=\"sol-card-header\">\n<div class=\"brand\">\u5957\u9910B<\/div>\n<h4>\ud83d\udd25 \u83f2\u65af\u66fc A1JE<\/h4>\n<div class=\"model\">Vitopend 100-W L1P27-A1JE \u00b7 24kW\u5e38\u89c4\u4e24\u7528\u7089<\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-body\">\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u5fb7\u56fd\u54c1\u724c \u00b7 \u5168\u7403\u9500\u91cf\u9886\u5148<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>24kW\u989d\u5b9a\u529f\u7387 \u00b7 \u677f\u6362\u5f0f\u6362\u70ed<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u4e0d\u9508\u94a2\u71c3\u70e7\u5668 \u00b7 \u8010\u7528\u53ef\u9760<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>LED\u6db2\u6676\u9762\u677f \u00b7 \u64cd\u4f5c\u7b80\u4fbf<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u7d27\u51d1\u673a\u8eab \u00b7 \u5b89\u88c5\u7075\u6d3b<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-footer\">\n<div class=\"sol-price\">\u00a55,800 <small>\/\u53f0<\/small><\/div>\n<div class=\"sol-price-note\">\u5305\u5b89\u88c5\u548c\u8fd0\u8f93<\/div>\n<p> <a href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\" class=\"sol-link\">\u67e5\u770b\u83f2\u65af\u66fc\u8be6\u60c5 \u2192<\/a>\n <\/div>\n<\/p>\n<\/div>\n<p> <!-- \u5957\u9910C \u66fc\u745e\u5fb7 --><\/p>\n<div class=\"sol-card fade-in\">\n<div class=\"sol-card-header\">\n<div class=\"brand\">\u5957\u9910C<\/div>\n<h4>\ud83d\udd25 \u66fc\u745e\u5fb7 HI.PRO<\/h4>\n<div class=\"model\">N1PB18-HI.PRO \u00b7 18kW\u53d8\u9891\u5355\u91c7\u6696\u7089<\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-body\">\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong>18kW\u7cbe\u51c6\u5339\u914d<\/strong> \u4e13\u4e3a66-80\u33a1\u91c7\u6696\u8bbe\u8ba1\uff0c\u907f\u514d\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u9891\u7e41\u542f\u505c<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong>\u76f4\u6d41\u53d8\u9891\u98ce\u673a<\/strong> \u6700\u5c0f\u8f93\u51fa\u529f\u7387\u4f4e\u81f3\u22483kW\uff0c\u4f4e\u70ed\u8d1f\u8377\u4e0b\u7a33\u5b9a\u8fd0\u884c<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong>\u5355\u91c7\u6696\u4e13\u7528<\/strong> \u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u8bbe\u8ba1\uff0c\u5f7b\u5e95\u89c4\u907f\u4e24\u7528\u7089\"\u70ed\u6c34\u62a2\u529f\u7387\"\u77db\u76fe<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong>\u51cf\u5c11\u542f\u505c=\u7701\u6c14<\/strong> \u53d8\u9891\u7cbe\u51c6\u5339\u914d\u8d1f\u8377\uff0c\u6d88\u9664\u65e0\u6548\u4ea7\u70ed\uff0c\u8fd0\u884c\u8d39\u7528\u66f4\u4f4e<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u56fd\u4ea7\u54c1\u724c \u00b7 \u53d8\u9891\u6280\u672f\u6210\u719f \u00b7 \u6027\u4ef7\u6bd4\u6781\u81f4\u4e4b\u9009<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-footer\">\n<div class=\"sol-price\">\u00a54,666 <small>\/\u53f0<\/small><\/div>\n<div class=\"sol-price-note\">\u5305\u5b89\u88c5\u548c\u8fd0\u8f93 \u00b7 \u6781\u81f4\u6027\u4ef7\u6bd4<\/div>\n<p> <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" class=\"sol-link\">\u67e5\u770b\u66fc\u745e\u5fb7\u8be6\u60c5 \u2192<\/a>\n <\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- ===== \u51b7\u51dd\u7089\u5347\u7ea7\u65b9\u6848 ===== --><\/p>\n<section class=\"section\" id=\"condensing\">\n<div class=\"section-header fade-in\">\n<div class=\"num\" style=\"background:var(--lm-green);\">+<\/div>\n<h2>\u51b7\u51dd\u7089\u5347\u7ea7\u65b9\u6848<\/h2>\n<p class=\"subtitle\">\u66f4\u9ad8\u70ed\u6548\u7387 \u00b7 \u66f4\u4f4e\u8fd0\u884c\u8d39\u7528 \u00b7 \u957f\u671f\u8282\u80fd\u4e4b\u9009<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"solution-cards\">\n <!-- \u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089 --><\/p>\n<div class=\"sol-card fade-in recommended\">\n<div class=\"rec-badge\">\u63a8\u8350<\/div>\n<div class=\"sol-card-header\">\n<div class=\"brand\">\u51b7\u51dd\u5347\u7ea7A<\/div>\n<h4>\ud83d\udd25 \u83f2\u65af\u66fc B1JG 25kW<\/h4>\n<div class=\"model\">\u5fb7\u56fd\u767e\u5e74\u54c1\u724c \u00b7 \u51b7\u51dd\u70ed\u56de\u6536\u6280\u672f<\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-body\">\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong style=\"font-size:18px;color:var(--lm-red);\">\u88f8\u673a\u4ef7 \u00a59,600<\/strong> \u5b89\u88c5\u8d39 \u00a5600 \u53e6\u8ba1<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u5fb7\u56fd\u767e\u5e74\u54c1\u724c \u00b7 \u5168\u7403\u9886\u5148<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u51b7\u51dd\u70ed\u56de\u6536\u6280\u672f <strong>\u70ed\u6548\u7387108%<\/strong><\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>25kW\u5927\u529f\u7387 \u00b7 \u91c7\u6696+\u70ed\u6c34\u5145\u8db3<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u5168\u9884\u6df7\u71c3\u70e7 \u00b7 \u8d85\u4f4e\u6392\u653e<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-footer\">\n<div class=\"sol-price\"><strong style=\"font-size:22px;\">\u00a59,600<\/strong> <small>\u88f8\u673a\u4ef7<\/small><span style=\"display:block;font-size:13px;color:var(--lm-gray-600);margin-top:4px;\">+ \u5b89\u88c5\u8d39 \u00a5600<\/span><\/div>\n<div class=\"sol-price-note\">\u5b89\u88c5\u8d39 \u00a5600 \u53e6\u8ba1 \u00b7 \u5fb7\u56fd\u539f\u88c5\u54c1\u8d28<\/div>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u535a\u4e163260W\u51b7\u51dd\u7089 --><\/p>\n<div class=\"sol-card fade-in\">\n<div class=\"sol-card-header\">\n<div class=\"brand\">\u51b7\u51dd\u5347\u7ea7B<\/div>\n<h4>\ud83d\udd25 \u535a\u4e16 3260W \u51b7\u51dd\u7089<\/h4>\n<div class=\"model\">\u5fb7\u56fd\u54c1\u724c \u00b7 1:8\u5bbd\u5e45\u8c03\u8282<\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-body\">\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong style=\"font-size:18px;color:var(--lm-red);\">\u88f8\u673a\u4ef7 \u00a58,600<\/strong> \u5b89\u88c5\u8d39 \u00a5600 \u53e6\u8ba1<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u5fb7\u56fd\u54c1\u724c \u00b7 \u54c1\u8d28\u53ef\u9760<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong>1:8\u5bbd\u5e45\u8c03\u8282<\/strong> \u7cbe\u51c6\u5339\u914d\u8d1f\u8377<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u91c7\u6696+\u70ed\u6c34 \u00b7 \u4e00\u5957\u641e\u5b9a<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u7d27\u51d1\u8bbe\u8ba1 \u00b7 \u5b89\u88c5\u7075\u6d3b<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-footer\">\n<div class=\"sol-price\"><strong style=\"font-size:22px;\">\u00a58,600<\/strong> <small>\u88f8\u673a\u4ef7<\/small><span style=\"display:block;font-size:13px;color:var(--lm-gray-600);margin-top:4px;\">+ \u5b89\u88c5\u8d39 \u00a5600<\/span><\/div>\n<div class=\"sol-price-note\">\u5b89\u88c5\u8d39 \u00a5600 \u53e6\u8ba1 \u00b7 \u5fb7\u7cfb\u54c1\u8d28<\/div>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u5c0f\u5361\u51b7\u51dd\u7089 --><\/p>\n<div class=\"sol-card fade-in\">\n<div class=\"sol-card-header\">\n<div class=\"brand\">\u51b7\u51dd\u5347\u7ea7C<\/div>\n<h4>\ud83d\udd25 \u5c0f\u5361 \u51b7\u51dd\u7089<\/h4>\n<div class=\"model\">5\u5e74\u8d28\u4fdd \u00b7 \u6570\u5b57\u5316\u51b7\u51dd\u7089<\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-body\">\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong style=\"font-size:18px;color:var(--lm-red);\">\u88f8\u673a\u4ef7 \u00a57,600<\/strong> \u5b89\u88c5\u8d39 \u00a5600 \u53e6\u8ba1<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span><strong>5\u5e74\u8d28\u4fdd<\/strong> \u552e\u540e\u65e0\u5fe7<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u6570\u5b57\u5316\u51b7\u51dd\u7089 \u00b7 \u667a\u80fd\u63a7\u5236<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u51b7\u51dd\u70ed\u56de\u6536 \u00b7 \u9ad8\u6548\u8282\u80fd<\/span><\/div>\n<div class=\"sol-feature\"><span class=\"dot\"><\/span><span>\u6027\u4ef7\u6bd4\u4e4b\u9009 \u00b7 \u51b7\u51dd\u5165\u95e8\u9996\u9009<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"sol-card-footer\">\n<div class=\"sol-price\"><strong style=\"font-size:22px;\">\u00a57,600<\/strong> <small>\u88f8\u673a\u4ef7<\/small><span style=\"display:block;font-size:13px;color:var(--lm-gray-600);margin-top:4px;\">+ \u5b89\u88c5\u8d39 \u00a5600<\/span><\/div>\n<div class=\"sol-price-note\">\u5b89\u88c5\u8d39 \u00a5600 \u53e6\u8ba1 \u00b7 5\u5e74\u8d28\u4fdd<\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"design-note fade-in\" style=\"margin-top:24px;\">\n \ud83d\udca1 <strong>\u5347\u7ea7\u5efa\u8bae\uff1a<\/strong>\u51b7\u51dd\u7089\u901a\u8fc7\u56de\u6536\u70df\u6c14\u4f59\u70ed\uff0c\u70ed\u6548\u7387\u53ef\u8fbe103%-108%\uff0c\u6bd4\u5e38\u89c4\u7089\u7701\u6c1415%-25%\u3002\u642d\u914d<a href=\"#heating-modes\" style=\"color:var(--lm-red);font-weight:600;\">\u8282\u80fd\u5957\u9910\u5730\u6696\u7cfb\u7edf<\/a>\uff08DE32+DE20\u7ba1\u5f84\uff09\uff0c\u51b7\u51dd\u8282\u80fd\u6548\u679c\u624d\u80fd\u5145\u5206\u53d1\u6325\u3002\n <\/div>\n<\/section>\n<p><!-- ===== Module 4: \u62a5\u4ef7\u548c\u56e2\u8d2d ===== --><\/p>\n<section class=\"section\" id=\"pricing\">\n<div class=\"section-header fade-in\">\n<div class=\"num\">4<\/div>\n<h2>\u62a5\u4ef7\u548c\u56e2\u8d2d<\/h2>\n<p class=\"subtitle\">618\u56e2\u8d2d\u4e13\u4eab\u4ef7 \u00b7 \u4e09\u79cd\u65b9\u6848\u6700\u7ec8\u5b9e\u4ed8\u5bf9\u6bd4<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"price-summary\">\n<div class=\"price-card fade-in\">\n<div class=\"label\">\ud83d\udd25 \u5957\u9910A<\/div>\n<div class=\"name\">\u535a\u4e16 G6100W \u65b9\u6848<\/div>\n<div class=\"amount\">\u00a534,854<\/div>\n<div class=\"breakdown\">\n<div><span>\u65e5\u7acb\u7a7a\u8c03\u90e8\u5206<\/span><span>\u00a522,720<\/span><\/div>\n<div><span>\u5730\u6696\u5957\u9910(66m\u00b2)<\/span><span>\u00a56,534<\/span><\/div>\n<div><span>\u535a\u4e16\u9505\u7089<\/span><span>\u00a55,600<\/span><\/div>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"price-card best fade-in\">\n<div class=\"label\">\ud83d\udd25 \u5957\u9910B<\/div>\n<div class=\"name\">\u83f2\u65af\u66fc A1JE \u65b9\u6848<\/div>\n<div class=\"amount\">\u00a535,054<\/div>\n<div class=\"breakdown\">\n<div><span>\u65e5\u7acb\u7a7a\u8c03\u90e8\u5206<\/span><span>\u00a522,720<\/span><\/div>\n<div><span>\u5730\u6696\u5957\u9910(66m\u00b2)<\/span><span>\u00a56,534<\/span><\/div>\n<div><span>\u83f2\u65af\u66fc\u9505\u7089<\/span><span>\u00a55,800<\/span><\/div>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"price-card fade-in\">\n<div class=\"label\">\ud83d\udd25 \u5957\u9910C<\/div>\n<div class=\"name\">\u66fc\u745e\u5fb7 HI.PRO \u65b9\u6848<\/div>\n<div class=\"amount\">\u00a533,920<\/div>\n<div class=\"breakdown\">\n<div><span>\u65e5\u7acb\u7a7a\u8c03\u90e8\u5206<\/span><span>\u00a522,720<\/span><\/div>\n<div><span>\u5730\u6696\u5957\u9910(66m\u00b2)<\/span><span>\u00a56,534<\/span><\/div>\n<div><span>\u66fc\u745e\u5fb7\u9505\u7089<\/span><span>\u00a54,666<\/span><\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p> <!-- \u5730\u6696\u5957\u9910\u8bf4\u660e --><\/p>\n<div class=\"design-note fade-in\" style=\"margin-bottom: 32px;\">\n \ud83d\udca1 <strong>\u5730\u6696\u5957\u9910\uff1a<\/strong>\u5e02\u573a\u901a\u914d\u65b9\u6848 66m\u00b2 \u00d7 \u00a599\/m\u00b2 = \u00a56,534\uff1b\u8282\u80fd\u5957\u9910\u56e2\u8d2d\u4ef7 66m\u00b2 \u00d7 \u00a5169\/m\u00b2 = \u00a511,154\uff08\u539f\u4ef7\u00a5179\/m\u00b2\uff0c\u56e2\u8d2d\u7701\u00a5660\uff09\u3002\u542b\u7ba1\u9053\u3001\u4fdd\u6e29\u3001\u63a7\u5236\u3001\u56de\u586b\u3001\u8bbe\u8ba1\u5b89\u88c5\u76d1\u7406\u53ca\u4e09\u65b9\u8054\u4fdd\u3002\u4f1f\u661fPE-RT\u963b\u6c27\u7ba1\/\u767d\u6676\u677f \u00b7 \u8bfa\u5c14\u6324\u5851\u677f \u00b7 \u4f1f\u661f\u955c\u9762\u53cd\u5c04\u819c \u00b7 \u66fc\u745e\u5fb7\u603b\u63a7\/\u5206\u63a7\u7cfb\u7edf \u00b7 C15\u788e\u77f3\u6df7\u51dd\u571f\u56de\u586b\u5c42 \u00b7 \u5382\u5bb6\u8d28\u4fdd50\u5e74\u3002\u8282\u80fd\u5957\u9910\u989d\u5916\u542bDE32+DE20\u7ba1\u5f84\u5347\u7ea7\u3001\u9505\u7089\u8054\u52a8\u63a7\u5236\u3001\u4e91\u7aef\u6570\u636e\u670d\u52a1\u3002\n <\/div>\n<div class=\"design-note fade-in\" style=\"margin-top:20px;text-align:center;font-size:15px;\">\n \ud83d\udca1 \u5730\u6696\u7cfb\u7edf\u652f\u6301\u4e24\u79cd\u6a21\u5f0f\u53ef\u9009\uff08\u5e02\u573a\u901a\u914d \u00a599\/m\u00b2 \u6216 \u8282\u80fd\u5957\u9910\u56e2\u8d2d\u4ef7 \u00a5169\/m\u00b2\uff09\uff0c<a href=\"#calculator\" style=\"color:var(--lm-red);font-weight:700;\">\u524d\u5f80\u62a5\u4ef7\u8ba1\u7b97\u5668 \u2192<\/a> \u9009\u62e9\u60a8\u7684\u6237\u578b\u5373\u5f97\u4e13\u5c5e\u56e2\u8d2d\u4ef7\u3002\n <\/div>\n<p> <!-- 618\u56e2\u8d2d\u6743\u76ca --><\/p>\n<h3 style=\"font-size:20px;font-weight:700;margin-bottom:20px;text-align:center;\" class=\"fade-in\">\ud83c\udf81 618\u56e2\u8d2d\u6743\u76ca\u660e\u7ec6<\/h3>\n<div class=\"benefits-grid\">\n<div class=\"benefit-item fade-in\">\n<div class=\"benefit-icon\" style=\"background:#FFF3E0;\">\ud83d\udcb0<\/div>\n<div>\n<h4>\u5b9a\u91d1\u81a8\u80c0 -\u00a5500<\/h4>\n<p>19.9\u5143\u4e92\u52a8\u5427\u5b9a\u91d1\u62b5500\u5143\uff0c\u5df2\u76f4\u63a5\u6263\u9664\uff08\u8212\u4eab\u5355\u98ce\u6247\u4e13\u5c5e\uff09<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"benefit-item fade-in\">\n<div class=\"benefit-icon\" style=\"background:#E8F5E9;\">\ud83d\udee1\ufe0f<\/div>\n<div>\n<h4>10\u5e74\u8d85\u957f\u8d28\u4fdd<\/h4>\n<p>\u8212\u4eab\u5ef6\u4fdd\u5361420\u5143\u5df2\u8ba1\u5165\uff0c\u8d28\u4fdd\u5ef6\u957f\u81f310\u5e74\uff08\u6574\u673a60\u4e2a\u6708+6\u4e2a\u6708\u88c5\u4fee\u671f+\u5ef6\u4fdd\uff09<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"benefit-item fade-in\">\n<div class=\"benefit-icon\" style=\"background:#E3F2FD;\">\u26a1<\/div>\n<div>\n<h4><a href=\"https:\/\/longmai-nt.com\/?page_id=518\" target=\"_blank\" style=\"color:inherit;text-decoration:none;\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/a><\/h4>\n<p>618\u7b7e\u7ea6\u81ea\u52a8\u52a0\u5165A\u7ec4\uff0c\u4eab\u5e74\u5ea6\u7528\u6c14\u8ddf\u8e2a+\u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807 <a href=\"https:\/\/longmai-nt.com\/?page_id=518\" target=\"_blank\" style=\"color:var(--lm-red);font-weight:600;\">\u67e5\u770b\u4e13\u9879\u8bf4\u660e\u2192<\/a><\/p>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"benefit-item fade-in\">\n<div class=\"benefit-icon\" style=\"background:#FCE4EC;\">\ud83c\udfe0<\/div>\n<div>\n<h4>50\u5e74\u5730\u6696\u8054\u4fdd<\/h4>\n<p>\u9f99\u8109+\u4f1f\u661f+\u4e2d\u56fd\u4eba\u4fdd\uff0c\u4e09\u65b950\u5e74\u4ea7\u54c1\u8054\u4fdd<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"benefit-item fade-in\">\n<div class=\"benefit-icon\" style=\"background:#F3E5F5;\">\ud83c\udff7\ufe0f<\/div>\n<div>\n<h4>618\u8212\u4eab8\u6298\u4f18\u60e0<\/h4>\n<p>\u4ee5\u4e0a\u603b\u4ef7\u5df2\u542b618\u8212\u4eab8\u6298\u4f18\u60e0<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"benefit-item fade-in\">\n<div class=\"benefit-icon\" style=\"background:#E0F7FA;\">\ud83d\udccb<\/div>\n<div>\n<h4>\u4f1f\u661f\u661f\u76d1\u7406<\/h4>\n<p>\u5382\u5bb6\u7b2c\u4e09\u65b9\u76d1\u7406 \u00b7 \u4e13\u4e1a\u6253\u538b+VR\u5168\u666f\u5b58\u6863<\/p>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"price-disclaimer fade-in\">\n \u26a0\ufe0f \u62a5\u4ef7\u6709\u6548\u671f\u81f32026\u5e747\u670830\u65e5\u3002\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57\u76d6\u7ae0\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002\n <\/div>\n<\/section>\n<p><!-- ===== \u5730\u6696\u65b9\u6848 \u00b7 \u53ef\u9009\u6a21\u5f0f ===== --><\/p>\n<section class=\"section\" id=\"heating-modes\">\n<div class=\"section-header fade-in\">\n<div class=\"num\" style=\"background:var(--lm-blue);\">+<\/div>\n<h2>\u5730\u6696\u65b9\u6848 \u00b7 \u53ef\u9009\u6a21\u5f0f<\/h2>\n<p class=\"subtitle\">\u540c\u4e00\u5957\u9505\u7089\u548c\u7a7a\u8c03\uff0c\u5730\u6696\u7cfb\u7edf\u4e5f\u53ef\u6309\u9884\u7b97\u548c\u8282\u80fd\u9700\u6c42\u81ea\u7531\u9009\u62e9<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"heating-mode-cards\">\n <!-- \u5e02\u573a\u901a\u914d\u65b9\u6848 --><\/p>\n<div class=\"mode-card fade-in\">\n<div class=\"mode-card-header\">\n<div class=\"mode-tag\">\u6a21\u5f0f\u4e00 \u00b7 \u5e02\u573a\u901a\u914d<\/div>\n<h4>\ud83d\udd27 \u5e02\u573a\u901a\u914d\u65b9\u6848<\/h4>\n<div class=\"mode-sub\">\u4f1f\u661f\u603b\u63a7 \u00b7 \u9ad8\u6027\u4ef7\u6bd4\u4e4b\u9009<\/div>\n<\/p>\n<\/div>\n<div class=\"mode-card-body\">\n<div class=\"mode-feature\"><span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><span>\u5730\u6696\u7ba1\uff1a\u4f1f\u661fPE-RT\u963b\u6c27\u7ba1 DE25+DE16<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><span>\u4fdd\u6e29\u677f\uff1a\u8bfa\u5c14\u6324\u5851\u677f 2cm<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><span>\u53cd\u5c04\u819c\uff1a\u666e\u901a\u53cd\u5c04\u819c<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><span>\u63a7\u5236\u5668\uff1a\u4f1f\u661f\u603b\u63a7\u7cfb\u7edf<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><span>\u8bbe\u8ba1+\u5b89\u88c5+\u76d1\u7406+\u4e09\u65b9\u8054\u4fdd \u5168\u5957\u670d\u52a1<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\" style=\"background:var(--lm-blue);\"><\/span><span>\u9002\u5408\uff1a\u9884\u7b97\u4f18\u5148\u3001\u57fa\u7840\u91c7\u6696\u9700\u6c42\u5bb6\u5ead<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"mode-card-footer\">\n<div class=\"mode-price\">\u00a599 <small>\/m\u00b2<\/small><\/div>\n<div class=\"mode-price-note\">66m\u00b2 \u5408\u8ba1 \u00a56,534 \u00b7 \u542b\u5168\u5957\u5b89\u88c5\u670d\u52a1<\/div>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u8282\u80fd\u5957\u9910 --><\/p>\n<div class=\"mode-card recommended fade-in\">\n<div class=\"rec-badge\">\u63a8\u8350<\/div>\n<div class=\"mode-card-header\">\n<div class=\"mode-tag\">\u6a21\u5f0f\u4e8c \u00b7 \u8282\u80fd\u73af\u4fdd\u5b9a\u5236<\/div>\n<h4>\u267b\ufe0f \u5730\u6696\u8282\u80fd\u5957\u9910<\/h4>\n<div class=\"mode-sub\">\u4f1f\u661f\u767d\u6676\u677f + \u66fc\u745e\u5fb7\u5206\u63a7 \u00b7 \u8fd0\u884c\u8d39\u7528\u770130%<\/div>\n<\/p>\n<\/div>\n<div class=\"mode-card-body\">\n<div class=\"mode-feature\"><span class=\"dot\"><\/span><span>\u5730\u6696\u7ba1\uff1a\u4f1f\u661fPE-RT DE32+DE20\uff08\u6d41\u91cf\u63d0\u5347\uff09<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\"><\/span><span>\u4fdd\u6e29\u677f\uff1a\u4f1f\u661f\u767d\u6676\u677f 3cm\uff08\u9ad8\u6548\u4fdd\u6e29\uff09<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\"><\/span><span>\u5206\u96c6\u6c34\u5668\uff1a\u4f1f\u661f\u9ad8\u7aef\u94dc\u8d28 + \u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\"><\/span><span>\u63a7\u5236\u5668\uff1a\u66fc\u745e\u5fb7WiFi\u667a\u80fd\u6e29\u63a7\u5668 \u00d7 N\u4e2a<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\"><\/span><span>\u8054\u52a8\u7cfb\u7edf\uff1a\u9505\u7089\u8054\u52a8\u63a7\u5236 \u00b7 \u6309\u9700\u542f\u505c\u66f4\u8282\u80fd<\/span><\/div>\n<div class=\"mode-feature\"><span class=\"dot\"><\/span><span>\u4e91\u7aef\u6570\u636e\u670d\u52a1 \u00b7 \u4e09\u65b9\u76d1\u7406 \u00b7 \u4e09\u65b9\u8054\u4fdd<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"mode-card-footer\">\n<div class=\"mode-price\">\u00a5169 <small>\/m\u00b2<\/small> <span style=\"font-size:14px;color:var(--lm-gray-600);text-decoration:line-through;font-weight:400;\">\u00a5179<\/span><\/div>\n<div class=\"mode-price-note\">66m\u00b2 \u5408\u8ba1 \u00a511,154 \u00b7 \u56e2\u8d2d\u4ef7\u7701\u00a5660 \u00b7 \u5e74\u8fd0\u884c\u8d39\u7701\u7ea630%<\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"design-note fade-in\" style=\"margin-top:32px;\">\n \ud83d\udca1 <strong>\u9009\u914d\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u4e24\u79cd\u5730\u6696\u6a21\u5f0f\u53ef\u4e0e Module 3 \u7684\u4e09\u79cd\u9505\u7089\u65b9\u6848\u4efb\u610f\u7ec4\u5408\u3002\u5e02\u573a\u901a\u914d\u65b9\u6848\uff08\u00a599\/m\u00b2\uff09\u4e3a\u6807\u914d\uff1b\u8282\u80fd\u5957\u9910\u56e2\u8d2d\u4ef7 \u00a5169\/m\u00b2\uff08\u539f\u4ef7\u00a5179\/m\u00b2\uff09\uff0c\u542b\u4f1f\u661f\u767d\u6676\u677f\u3001DE32+DE20\u7ba1\u5f84\u3001\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\u53ca\u9505\u7089\u8054\u52a8\u7cfb\u7edf\uff0c\u8fd0\u884c\u8d39\u7528\u7701\u7ea630%\u3002\u5b9e\u9645\u91c7\u6696\u9762\u79ef\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002\n <\/div>\n<p> <!-- \u5730\u6696\u914d\u7f6e\u5206\u5c42\u5bf9\u6bd4\u8868 --><\/p>\n<div class=\"fade-in\" style=\"margin-top:48px;\">\n<h3 style=\"font-size:20px;font-weight:700;margin-bottom:4px;text-align:center;\">\ud83d\udcca \u4e24\u79cd\u5730\u6696\u65b9\u6848 \u00b7 \u6838\u5fc3\u5dee\u5f02\u4e00\u89c8<\/h3>\n<p style=\"text-align:center;font-size:14px;color:var(--lm-gray-600);margin-bottom:24px;\">\u51b7\u51dd\u7089\u8282\u80fd\u7684\u524d\u63d0\u662f\"\u7cfb\u7edf\u5339\u914d\"\uff0c\u7ba1\u5f84\u548c\u63a7\u5236\u65b9\u5f0f\u51b3\u5b9a\u6700\u7ec8\u6548\u679c<\/p>\n<div class=\"spec-table-wrap\">\n<table class=\"spec-table\">\n<thead>\n<tr>\n<th style=\"min-width:140px;\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n<th style=\"background:#FFF8E1;\">\ud83d\udd27 \u5e02\u573a\u901a\u914d \u00b7 \u00a599\/m\u00b2<\/th>\n<th style=\"background:#E8F5E9;\">\u267b\ufe0f \u8282\u80fd\u5957\u9910 \u00b7 \u00a5169\/m\u00b2\uff08\u56e2\u8d2d\u4ef7\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"label-col\">\u4e3b\u7ba1 \/ \u76d8\u7ba1\u7ba1\u5f84<\/td>\n<td>DE25\u4e3b\u7ba1 + DE16\u76d8\u7ba1<\/td>\n<td style=\"background:rgba(46,125,50,0.04);font-weight:600;\">DE32\u4e3b\u7ba1 + DE20\u76d8\u7ba1<span style=\"font-weight:400;color:var(--lm-green);display:block;font-size:12px;margin-top:2px;\">\u5927\u6d41\u91cf\u4f4e\u6e29\u8fd0\u884c \u00b7 \u51b7\u51dd\u7089\u8282\u80fd\u4f18\u52bf\u5145\u5206\u53d1\u6325<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u4fdd\u6e29\u677f<\/td>\n<td>\u8bfa\u5c14\u6324\u5851\u677f 2cm<\/td>\n<td style=\"background:rgba(46,125,50,0.04);font-weight:600;\">\u4f1f\u661f\u767d\u6676\u677f 3cm<span style=\"font-weight:400;color:var(--lm-green);display:block;font-size:12px;margin-top:2px;\">\u4fdd\u6e29\u6027\u80fd\u66f4\u4f18 \u00b7 \u5411\u4e0b\u70ed\u635f\u5931\u51cf\u5c1130%+<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u53cd\u5c04\u819c<\/td>\n<td>\u4f1f\u661f\u955c\u9762\u53cd\u5c04\u819c<\/td>\n<td style=\"background:rgba(46,125,50,0.04);font-weight:600;\">\u4f1f\u661f\u955c\u9762\u5168\u94dd\u53cd\u5c04\u819c<span style=\"font-weight:400;color:var(--lm-green);display:block;font-size:12px;margin-top:2px;\">\u7eaf\u94dd\u5c42\u6297\u6c34\u6ce5\u8150\u8680 \u00b7 \u957f\u671f\u53cd\u5c04\u6027\u80fd\u7a33\u5b9a<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u63a7\u5236\u7cfb\u7edf<\/td>\n<td>\u4f1f\u661f\u603b\u63a7\u7cfb\u7edf\uff08\u7edf\u4e00\u542f\u505c\uff09<\/td>\n<td style=\"background:rgba(46,125,50,0.04);font-weight:600;\">\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7 + \u9505\u7089\u8054\u52a8<span style=\"font-weight:400;color:var(--lm-green);display:block;font-size:12px;margin-top:2px;\">\u6309\u9700\u542f\u505c \u00b7 \u6d88\u9664\u65e0\u6548\u4ea7\u70ed \u00b7 \u8282\u80fd10-25%<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u51b7\u51dd\u7089\u5339\u914d\u5ea6<\/td>\n<td><span style=\"color:#E65100;\">\u26a0\ufe0f \u7ba1\u5f84\u53d7\u9650 \u00b7 \u4f4e\u6e29\u8fd0\u884c\u6548\u679c\u6253\u6298<\/span><\/td>\n<td style=\"background:rgba(46,125,50,0.04);\"><span style=\"color:var(--lm-green);font-weight:600;\">\u2705 \u5927\u6d41\u91cf \u00b7 \u51b7\u51dd\u7089\u9ad8\u6548\u533a\u5145\u5206\u53d1\u6325<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u8fd0\u884c\u8d39\u7528\u53c2\u8003<\/td>\n<td>\u5e38\u89c4\u8d39\u7528\u57fa\u51c6<\/td>\n<td style=\"background:rgba(46,125,50,0.04);font-weight:600;\">\u5e74\u7701\u7ea630%<span style=\"font-weight:400;display:block;font-size:12px;margin-top:2px;color:var(--lm-gray-600);\">\u8f9b\u603b\u6848\u4f8b\uff1a450\u33a1\u4e24\u8054\u4f9b\u6708\u8d39\uff1c2000\u5143\uff0c\u90bb\u5c45\u770150%<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"label-col\">\u56e2\u8d2d\u8d60\u9001<\/td>\n<td>\u2014<\/td>\n<td style=\"background:rgba(46,125,50,0.04);\"><span style=\"color:var(--lm-red);font-weight:700;\">\u8d60\u9001\u9505\u7089\u8054\u52a8\u63a7\u5236 + \u4e91\u7aef\u6570\u636e\u670d\u52a1<\/span><span style=\"display:block;font-size:12px;margin-top:2px;color:var(--lm-gray-600);\">\u5e74\u5ea6\u7528\u6c14\u8ddf\u8e2a \u00b7 \u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p> <!-- \u51b7\u51dd\u7089\u8282\u80fd\u6027\u8b66\u793a\u5361\u7247 --><\/p>\n<div class=\"fade-in\" style=\"margin-top:48px;\">\n<div style=\"background:linear-gradient(135deg,#FFF8E1,#FFF3E0);border-radius:var(--lm-radius);padding:28px 24px;border-left:4px solid #E65100;\">\n<div style=\"display:flex;align-items:flex-start;gap:12px;margin-bottom:20px;\">\n <span style=\"font-size:32px;line-height:1;\">\u26a0\ufe0f<\/span><\/p>\n<div>\n<h4 style=\"font-size:18px;font-weight:800;color:#E65100;margin-bottom:6px;\">\u907f\u5751\u63d0\u793a\uff1a\u51b7\u51dd\u7089\u4e70\u56de\u6765\uff0c\u4e0d\u4e00\u5b9a\u8282\u80fd\uff01<\/h4>\n<p style=\"font-size:13px;color:var(--lm-gray-600);\">\u5730\u6696\u662f\"\u7cfb\u7edf\u5339\u914d\"\u800c\u975e\"\u8bbe\u5907\u5806\u780c\"\u2014\u2014\u9009\u9519\u5730\u6696\u914d\u7f6e\uff0c\u51b7\u51dd\u7089\u7684\u9ad8\u6548\u70ed\u6548\u7387\u65e0\u6cd5\u53d1\u6325\uff0c\u591a\u82b1\u7684\u94b1\u5c31\u767d\u8d39\u4e86<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div style=\"font-size:14px;line-height:2;color:var(--lm-gray-900);margin-bottom:20px;\">\n<p style=\"margin-bottom:8px;\"><strong style=\"color:var(--lm-green);\">\u2705 \u51b7\u51dd\u7089\u8282\u80fd\u7684\u4e24\u4e2a\u524d\u63d0\uff08\u7f3a\u4e00\u4e0d\u53ef\uff09<\/strong><\/p>\n<div style=\"padding-left:16px;margin-bottom:16px;\">\n<p>\u2460 <strong>\u4f4e\u6e29\u7cfb\u7edf<\/strong>\uff1a\u4f9b\u6c34\u6e29\u5ea6\u226455\u2103\uff08\u6700\u597d\u226450\u2103\uff09\uff0c\u51b7\u51dd\u56de\u6536\u529f\u80fd\u624d\u542f\u52a8\uff0c\u70ed\u6548\u7387\u53ef\u8fbe103-108%<\/p>\n<p>\u2461 <strong>\u7cfb\u7edf\u5339\u914d\u5230\u4f4d<\/strong>\uff1a\u6c34\u529b\u5e73\u8861 + \u8054\u52a8\u63a7\u5236 + \u5927\u6d41\u91cf\u7ba1\u5f84\uff08DE32\u4e3b\u7ba1+DE20\u76d8\u7ba1\uff09<\/p>\n<\/p>\n<\/div>\n<p style=\"margin-bottom:8px;\"><strong style=\"color:#E65100;\">\u274c \u5e02\u573a\u901a\u914d\u65b9\u6848\uff08DE25+DE16\uff09\u7684\u5c40\u9650<\/strong><\/p>\n<div style=\"padding-left:16px;margin-bottom:16px;color:var(--lm-gray-800);\">\n<p>\u2014 \u7ba1\u5f84\u504f\u5c0f \u2192 \u6d41\u91cf\u53d7\u9650 \u2192 \u4f4e\u6e29\u8fd0\u884c\u65f6\u8fdc\u7aef\u652f\u8def\u6d41\u91cf\u4e0d\u8db3\u3001\u672b\u7aef\u4e0d\u70ed<\/p>\n<p>\u2014 \u9505\u7089\u88ab\u8feb\u63d0\u9ad8\u4f9b\u6c34\u6e29\u5ea6\u8865\u507f \u2192 <strong>\u51b7\u51dd\u56de\u6536\u529f\u80fd\u65e0\u6cd5\u542f\u52a8<\/strong> \u2192 \u5b9e\u9645\u6548\u7387\u4e0e\u666e\u901a\u7089\u65e0\u5f02<\/p>\n<p>\u2014 \u7b80\u5355\u8bf4\uff1a\u7528\u901a\u914d\u5730\u6696\u914d\u51b7\u51dd\u7089\uff0c\u7b49\u4e8e\"\u4e70\u5954\u9a70\u5f00\u5728\u4e61\u6751\u571f\u8def\u4e0a\"<\/p>\n<\/p>\n<\/div>\n<p style=\"margin-bottom:8px;\"><strong style=\"color:var(--lm-green);\">\u2705 \u8282\u80fd\u5957\u9910\uff08DE32+DE20\uff09\u7684\u4f18\u52bf<\/strong><\/p>\n<div style=\"padding-left:16px;color:var(--lm-gray-800);\">\n<p>\u2014 \u6d41\u91cf\u5145\u8db3\u3001\u7cfb\u7edf\u963b\u529b\u5c0f \u2192 \u4f4e\u6e29\u5927\u6d41\u91cf\u8fd0\u884c \u2192 \u672b\u7aef\u70ed\u91cf\u5206\u914d\u5747\u5300<\/p>\n<p>\u2014 \u51b7\u51dd\u7089\u51b7\u51dd\u56de\u6536\u529f\u80fd\u6b63\u5e38\u542f\u52a8 \u2192 <strong>\u7efc\u5408\u8282\u80fd\u6548\u679c\u660e\u663e<\/strong> \u2192 \u8fd0\u884c\u8d39\u7528\u770130%+<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div style=\"padding:16px 20px;background:rgba(198,40,40,0.06);border-radius:8px;font-size:13px;color:var(--lm-red);line-height:1.9;\">\n \ud83d\udca1 <strong>\u9009\u8d2d\u5efa\u8bae\uff1a<\/strong>\u5982\u679c\u9009\u51b7\u51dd\u7089\u65b9\u6848\uff08\u83f2\u65af\u66fcA1JE\u3001\u535a\u4e16G6100W\u5747\u4e3a\u51b7\u51dd\u7089\uff09\uff0c<strong>\u5f3a\u70c8\u5efa\u8bae\u540c\u6b65\u9009\u8282\u80fd\u5957\u9910\u5730\u6696\u7cfb\u7edf<\/strong>\uff0c\u5426\u5219\u51b7\u51dd\u7089\"\u9ad8\u6548\u8282\u80fd\"\u53ea\u662f\u4e00\u53e5\u7a7a\u8bdd\u3002\u5e02\u573a\u901a\u914d\u65b9\u6848\u66f4\u9002\u5408\u914d\u5408\u5e38\u89c4\u4e24\u7528\u7089\u4f7f\u7528\uff0c\u4ef7\u683c\u66f4\u4eb2\u6c11\u3002<br \/>\n <span style=\"font-size:12px;color:var(--lm-gray-600);\">\ud83d\udccb \u6570\u636e\u4f9d\u636e\uff1a\u4f9d\u636e\u9f99\u8109\u6696\u901a\u5730\u6696\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7\uff08page_id=1976\uff09\u5206\u6790\u53ca\u591a\u4e2a\u5ba2\u6237\u6848\u4f8b\uff08\u4e07\u8001\u5e08\/\u674e\u6d77\/\u8f9b\u603b\uff09\u5b9e\u6d4b\u9a8c\u8bc1\u3002<\/span>\n <\/div>\n<\/p>\n<\/div>\n<\/div>\n<p><!-- \u58c1\u6302\u7089\u8fd0\u884c\u539f\u7406\uff08\u5730\u6696\u8fd0\u884c\u539f\u7406\uff09 --><\/p>\n<div class=\"boiler-section fade-in\" style=\"margin-top:48px;\">\n<h3 style=\"font-size:20px;font-weight:700;margin-bottom:4px;text-align:center;\">\ud83d\udd2c \u58c1\u6302\u7089\u8fd0\u884c\u539f\u7406<\/h3>\n<p style=\"text-align:center;font-size:14px;color:var(--lm-gray-600);margin-bottom:24px;\">\u4e09\u79cd\u5de5\u51b5\uff08\u91c7\u6696\/\u751f\u6d3b\u70ed\u6c34\/\u5c0f\u5faa\u73af\uff09\u6c34\u8def\u52a8\u6001\u6f14\u793a<\/p>\n<p> <button class=\"accordion-trigger\" id=\"boilerTrigger\" onclick=\"toggleAccordion()\"><br \/>\n <span>\ud83d\udcd6 \u70b9\u51fb\u5c55\u5f00\u58c1\u6302\u7089\u8fd0\u884c\u539f\u7406\u52a8\u6001\u56fe<\/span><br \/>\n <span class=\"arrow\">\u25bc<\/span><br \/>\n <\/button><\/p>\n<div class=\"accordion-content\" id=\"boilerContent\">\n <iframe src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-bgl-bigualu-bigualuyunxingyuanli.html\"\n style=\"width:100%; height:2200px; border:none;\"\n scrolling=\"yes\"\n loading=\"lazy\"><br \/>\n <\/iframe>\n <\/div>\n<\/p>\n<\/div>\n<p><!-- \u5730\u6696\u6210\u672c\u660e\u7ec6\u5206\u6790\uff08\u624b\u98ce\u7434\u6298\u53e0\uff09 --><\/p>\n<div class=\"boiler-section\" style=\"margin-top:20px;\">\n <button type=\"button\" class=\"accordion-trigger\" id=\"costTrigger\" onclick=\"toggleCostAccordion()\"><br \/>\n <span>\ud83d\udcca \u70b9\u51fb\u5c55\u5f00\u5730\u6696\u6210\u672c\u660e\u7ec6\u5206\u6790<\/span><br \/>\n <span class=\"arrow\">\u25bc<\/span><br \/>\n <\/button><\/p>\n<div class=\"accordion-content\" id=\"costContent\">\n <iframe src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-dn-dncbfx-dinuanchengbenfenxi.html\" style=\"width:100%;height:800px;border:none;\" scrolling=\"yes\" loading=\"lazy\"><\/iframe>\n <\/div>\n<\/p>\n<\/div>\n<p><!-- ===== \u5730\u6696\u907f\u5751\u6307\u5357\uff08\u624b\u98ce\u7434\u6298\u53e0\uff09 ===== --><\/p>\n<div class=\"boiler-section\" style=\"margin-top:10px; margin-bottom:20px;\">\n <button type=\"button\" class=\"accordion-trigger\" id=\"dinuanBikengTrigger\" onclick=\"toggleDinuanBikeng()\"><br \/>\n <span>\ud83d\udee1\ufe0f \u70b9\u51fb\u5c55\u5f00\u5730\u6696\u907f\u5751\u6307\u5357<\/span><br \/>\n <span class=\"arrow\">\u25bc<\/span><br \/>\n <\/button><\/p>\n<div class=\"accordion-content\" id=\"dinuanBikengContent\">\n <iframe src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-dn-dnbkzn-dinuan-bikengzhinan.html\" width=\"100%\" height=\"1200\" frameborder=\"0\" scrolling=\"auto\" style=\"max-width:720px;margin:0 auto;display:block;\" loading=\"lazy\"><\/iframe>\n <\/div>\n<\/div>\n<\/section>\n<section class=\"section\" id=\"calculator\">\n<div class=\"section-header fade-in\">\n<div class=\"num\" style=\"background:var(--lm-green);\">\u03b2<\/div>\n<h2>\u56e2\u8d2d\u4ef7\u683c\u8ba1\u7b97\u5668<\/h2>\n<p class=\"subtitle\">\u9009\u62e9\u6237\u578b\u548c\u7cfb\u7edf\u914d\u7f6e\uff0c\u4e00\u952e\u7b97\u51fa\u60a8\u7684\u4e13\u5c5e\u56e2\u8d2d\u4ef7<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"calc-section fade-in\">\n<div class=\"calc-form\">\n<div class=\"calc-field\">\n <label for=\"calcHouseType\">\ud83c\udfe0 \u9009\u62e9\u6237\u578b<\/label><br \/>\n <select id=\"calcHouseType\" onchange=\"onHouseTypeChange()\"><option value=\"A\" selected>A\u6237\u578b \u00b7 99m\u00b2\uff083\u5ba42\u53851\u536b\uff09\u00b7 \u6e05\u6c34\u623f<\/option><option value=\"B\">B\u6237\u578b \u00b7 88m\u00b2\uff082\u5ba42\u53851\u536b\uff09\u00b7 \u7cbe\u88c5\u623f<\/option><option value=\"C\">C\u6237\u578b \u00b7 120m\u00b2\uff084\u5ba42\u53852\u536b\uff09\u00b7 \u7cbe\u88c5\u623f<\/option><option value=\"custom\">\u81ea\u5b9a\u4e49\u9762\u79ef<\/option><\/select>\n <\/div>\n<div class=\"calc-field\">\n <label for=\"calcHeatingArea\">\ud83d\udcd0 \u91c7\u6696\u9762\u79ef\uff08m\u00b2\uff09<\/label><br \/>\n <input type=\"number\" id=\"calcHeatingArea\" value=\"66\" min=\"20\" max=\"200\" step=\"1\" onchange=\"calcUpdate()\">\n <\/div>\n<div class=\"calc-field\">\n <label for=\"calcBoiler\">\ud83d\udd25 \u9505\u7089\u65b9\u6848<\/label><br \/>\n <select id=\"calcBoiler\" onchange=\"calcUpdate()\"><option value=\"C\">\u5957\u9910C \u00b7 \u66fc\u745e\u5fb7 HI.PRO\uff08\u00a54,666\uff09\u2014 \u6027\u4ef7\u6bd4\u9996\u9009<\/option><option value=\"A\">\u5957\u9910A \u00b7 \u535a\u4e16 G6100W\uff08\u00a55,600\uff09<\/option><option value=\"B\" selected>\u5957\u9910B \u00b7 \u83f2\u65af\u66fc A1JE\uff08\u00a55,800\uff09\u2014 \u70ed\u9500<\/option><\/select>\n <\/div>\n<div class=\"calc-field\">\n <label for=\"calcHeatingMode\">\u2668\ufe0f \u5730\u6696\u65b9\u6848\u6a21\u5f0f<\/label><br \/>\n <select id=\"calcHeatingMode\" onchange=\"calcUpdate()\"><option value=\"standard\" selected>\u5e02\u573a\u901a\u914d \u00b7 \u00a599\/m\u00b2\uff08\u4f1f\u661f\u603b\u63a7\uff09<\/option><option value=\"energy\">\u8282\u80fd\u5957\u9910 \u00b7 \u00a5169\/m\u00b2\uff08\u56e2\u8d2d\u4ef7 \u539f\u4ef7\u00a5179\uff09<\/option><\/select>\n <\/div>\n<\/p>\n<\/div>\n<div class=\"calc-result\" id=\"calcResult\">\n<div class=\"result-header\">\n<div class=\"result-title\">\ud83d\udccb \u60a8\u7684\u56e2\u8d2d\u4e13\u4eab\u4ef7<\/div>\n<div class=\"result-total\" id=\"calcTotal\">\u00a535,054<\/div>\n<\/p>\n<\/div>\n<div class=\"calc-breakdown\" id=\"calcBreakdown\">\n<div class=\"bd-row\"><span>\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03<\/span><span id=\"bdAC\">\u00a522,720<\/span><\/div>\n<div class=\"bd-row\"><span>\u5730\u6696\u7cfb\u7edf <span id=\"bdArea\">66<\/span>m\u00b2\uff08<span id=\"bdMode\">\u6807\u51c6<\/span>\u65b9\u6848\uff09<\/span><span id=\"bdHeating\">\u00a56,534<\/span><\/div>\n<div class=\"bd-row\"><span>\u9505\u7089\uff08<span id=\"bdBoiler\">\u83f2\u65af\u66fc A1JE<\/span>\uff09<\/span><span id=\"bdBoilerPrice\">\u00a55,800<\/span><\/div>\n<div class=\"bd-row\"><span>\u5b9a\u91d1\u81a8\u80c0\u4f18\u60e0\uff0819.9\u62b5500\uff09<\/span><span id=\"bdDeposit\">-\u00a5500<\/span><\/div>\n<div class=\"bd-row bd-total\"><span>\u56e2\u8d2d\u4e13\u4eab\u603b\u4ef7<\/span><span id=\"bdTotal\">\u00a535,054<\/span><\/div>\n<\/p>\n<\/div>\n<div class=\"calc-note\">\n \u26a0\ufe0f \u4ee5\u4e0a\u4ef7\u683c\u5df2\u542b618\u8212\u4eab8\u6298\u4f18\u60e0\u53ca\u5b9a\u91d1\u81a8\u80c0\u62b5\u6263\u3002\u62a5\u4ef7\u6709\u6548\u671f\u81f32026\u5e747\u670830\u65e5\uff0c\u6700\u7ec8\u4ef7\u683c\u4ee5\u53cc\u65b9\u7b7e\u5b57\u786e\u8ba4\u7684\u65b9\u6848\u4e3a\u51c6\u3002\u91c7\u6696\u9762\u79ef\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\uff0c\u591a\u9000\u5c11\u8865\u3002\n <\/div>\n<\/p>\n<\/div>\n<\/div>\n<p><!-- ===== \u8212\u4eab\u62a5\u4ef7\u8ba1\u7b97\u5668\uff08\u624b\u98ce\u7434\u6298\u53e0\uff09 ===== --><\/p>\n<div class=\"boiler-section\" style=\"margin-top:10px; margin-bottom:20px;\">\n <button type=\"button\" class=\"accordion-trigger\" id=\"shuxiangQuoteTrigger\" onclick=\"toggleShuxiangQuote()\"><br \/>\n <span>\ud83d\udcb0 \u70b9\u51fb\u5c55\u5f00\u8212\u4eab\u7cfb\u5217\u62a5\u4ef7\u8ba1\u7b97\u5668<\/span><br \/>\n <span class=\"arrow\">\u25bc<\/span><br \/>\n <\/button><\/p>\n<div class=\"accordion-content\" id=\"shuxiangQuoteContent\">\n <iframe loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-sxbj-ex-shuxiang-baojiajisuanqi.html\" width=\"100%\" height=\"1200\" frameborder=\"0\" scrolling=\"auto\" style=\"max-width:720px;margin:0 auto;display:block;\"><\/iframe>\n <\/div>\n<\/div>\n<\/section>\n<p><!-- ===== Module 5: \u65bd\u5de5\u7ec4\u7ec7\u548c\u670d\u52a1\u4fdd\u969c ===== --><\/p>\n<section class=\"section\" id=\"construction\">\n<div class=\"section-header fade-in\">\n<div class=\"num\">5<\/div>\n<h2>\u65bd\u5de5\u7ec4\u7ec7\u548c\u670d\u52a1\u4fdd\u969c<\/h2>\n<p class=\"subtitle\">\u7cbe\u5de56+2\u5b89\u88c5\u4f53\u7cfb \u00b7 \u4e13\u6ce8\u53ef\u89c6\u5316\u670d\u52a1<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<p> <!-- \u65bd\u5de5\u6d41\u7a0b --><\/p>\n<h3 style=\"font-size:18px;font-weight:700;margin-bottom:20px;text-align:center;\" class=\"fade-in\">\ud83d\udcd0 \u6807\u51c6\u5316\u65bd\u5de5\u6d41\u7a0b<\/h3>\n<div class=\"construction-flow fade-in\">\n<div class=\"flow-step\">\n<div class=\"step-num\">1<\/div>\n<h4>\u4e0a\u95e8\u8bca\u65ad<\/h4>\n<p>\u73b0\u573a\u52d8\u6d4b\u6237\u578b\u7ed3\u6784<br \/>\u786e\u5b9a\u8bbe\u5907\u4f4d\u7f6e<\/p>\n<p> <span class=\"flow-arrow\">\u2192<\/span>\n <\/div>\n<div class=\"flow-step\">\n<div class=\"step-num\">2<\/div>\n<h4>\u4e09\u65b9\u5b9a\u4f4d<\/h4>\n<p>\u8bbe\u8ba1\u5e08+\u5b89\u88c5\u5e08+\u4e1a\u4e3b<br \/>\u73b0\u573a\u786e\u8ba4\u65b9\u6848<\/p>\n<p> <span class=\"flow-arrow\">\u2192<\/span>\n <\/div>\n<div class=\"flow-step\">\n<div class=\"step-num\">3<\/div>\n<h4>\u7cbe\u5de5\u5b89\u88c5<\/h4>\n<p>\u7ecf\u65e5\u7acb\u6280\u672f\u57f9\u8bad\u8003\u6838\u540e\u4e0a\u5c97\u7684\u6280\u5e08\u65bd\u5de5<br \/>\u65e5\u7acb\u5382\u5bb6\u57f9\u8bad\u8003\u6838<\/p>\n<p> <span class=\"flow-arrow\">\u2192<\/span>\n <\/div>\n<div class=\"flow-step\">\n<div class=\"step-num\">4<\/div>\n<h4>\u6253\u538b\u9a8c\u6536<\/h4>\n<p>\u4f1f\u661f\u661f\u76d1\u7406<br \/>\u4e13\u4e1a\u6253\u538b+VR\u5168\u666f<\/p>\n<p> <span class=\"flow-arrow\">\u2192<\/span>\n <\/div>\n<div class=\"flow-step\">\n<div class=\"step-num\">5<\/div>\n<h4>\u4ea4\u4ed8\u4f7f\u7528<\/h4>\n<p>\u7cfb\u7edf\u8c03\u8bd5\u5b8c\u6210<br \/>\u4f7f\u7528\u6307\u5bfc+\u5b58\u6863<\/p>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u5b89\u88c5\u5de5\u827a\u56fe Slider --><\/p>\n<div class=\"install-slider-section fade-in\">\n<h3 style=\"font-size:18px;font-weight:700;margin-bottom:16px;\">\ud83d\udcf7 \u5b89\u88c5\u5de5\u827a\u5b9e\u62cd<\/h3>\n<div class=\"slider-container\" id=\"installSlider\">\n<div class=\"slider-track\" id=\"installTrack\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143253.jpg\" alt=\"\u7cbe\u5de56+2-\u4e13\u5c5e\u56fe\u7eb8\u4e0e\u73b0\u573a\u5b9a\u4f4d\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143320-1.jpg\" alt=\"\u7cbe\u5de56+2-\u8bbe\u5907\u4e0e\u6750\u6599\u900f\u660e\u9a8c\u6536\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143239.jpg\" alt=\"\u7cbe\u5de56+2-\u6309\u56fe\u65bd\u5de5\u4e0e\u73b0\u573a\u6838\u5bf9\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a.jpg\" alt=\"\u7cbe\u5de56+2-\u7ba1\u9053\u710a\u63a5\u6807\u51c6\u5de5\u827a\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/\u5fae\u4fe1\u56fe\u7247_20260428181008_36_182.jpg\" alt=\"\u7cbe\u5de56+2-\u9690\u853d\u5de5\u7a0b\u8054\u5408\u9a8c\u6536\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u62bd\u771f\u7a7a\u4fdd\u538b-scaled.jpg\" alt=\"\u7cbe\u5de56+2-\u7cfb\u7edf\u7cbe\u51c6\u8c03\u8bd5\u4ea4\u4ed8\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u8c03\u8bd5\u4e00\u5bf9\u4e00\u6559\u5b66.jpg\" alt=\"\u7cbe\u5de56+2-\u4e00\u5bf9\u4e00\u4f7f\u7528\u6559\u5b66\" loading=\"lazy\"><br \/>\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5ba2\u6237\u6863\u6848\u4e66-1.jpg\" alt=\"\u7cbe\u5de56+2-\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\" loading=\"lazy\">\n <\/div>\n<p> <button class=\"slider-btn prev\" onclick=\"slidePrev('install')\">\u2039<\/button><br \/>\n <button class=\"slider-btn next\" onclick=\"slideNext('install')\">\u203a<\/button><\/p>\n<div class=\"slider-dots\" id=\"installDots\"><\/div>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u8d28\u4fdd\u4f53\u7cfb --><\/p>\n<h3 style=\"font-size:18px;font-weight:700;margin-bottom:20px;text-align:center;\" class=\"fade-in\">\ud83d\udee1\ufe0f \u8d28\u4fdd\u4fdd\u969c\u4f53\u7cfb<\/h3>\n<div class=\"warranty-grid fade-in\">\n<div class=\"warranty-card\">\n<div class=\"w-icon\">\ud83c\udfed<\/div>\n<h4>\u65e5\u7acb\u6388\u6743\u7ecf\u9500\u5546<\/h4>\n<div class=\"w-year\">10<small>\u5e74<\/small><\/div>\n<p>\u5b98\u65b9\u8ba4\u8bc1\u5b89\u88c5\u670d\u52a1\u5546<br \/>\u8212\u4eab\u5ef6\u4fdd\u5361 \u00b7 \u6574\u673a60\u4e2a\u6708+\u5ef6\u4fdd<\/p>\n<\/p>\n<\/div>\n<div class=\"warranty-card\">\n<div class=\"w-icon\">\ud83d\udee1\ufe0f<\/div>\n<h4>\u4e2d\u56fd\u4eba\u4fdd\u627f\u4fdd<\/h4>\n<div class=\"w-year\">50<small>\u5e74<\/small><\/div>\n<p>\u9f99\u8109+\u4f1f\u661f+\u4e2d\u56fd\u4eba\u4fdd<br \/>\u4e09\u65b950\u5e74\u5730\u6696\u4ea7\u54c1\u8054\u4fdd<\/p>\n<\/p>\n<\/div>\n<div class=\"warranty-card\">\n<div class=\"w-icon\">\u26a1<\/div>\n<h4><a href=\"https:\/\/longmai-nt.com\/?page_id=518\" target=\"_blank\" style=\"color:inherit;text-decoration:none;\">\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/a><\/h4>\n<div class=\"w-year\">10<small>\u5e74<\/small><\/div>\n<p>\u5e74\u5ea6\u7528\u6c14\u8ddf\u8e2a<br \/>\u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807<\/p>\n<p style=\"margin-top:8px;\"><a href=\"https:\/\/longmai-nt.com\/?page_id=518\" target=\"_blank\" style=\"font-size:12px;color:var(--lm-red);text-decoration:none;font-weight:600;\">\ud83d\udccb \u67e5\u770b\u4e13\u9879\u8bf4\u660e \u2192<\/a><\/p>\n<\/p>\n<\/div>\n<div class=\"warranty-card\">\n<div class=\"w-icon\">\ud83d\udccb<\/div>\n<h4>\u6b63\u89c4\u8d44\u8d28<\/h4>\n<div class=\"w-year\" style=\"font-size:20px;\">\u2705<\/div>\n<p>\u8425\u4e1a\u6267\u7167 \u00b7 \u673a\u7535\u5b89\u88c5\u8d44\u8d28<br \/>\u5b89\u5168\u751f\u4ea7\u8bb8\u53ef\u8bc1 \u00b7 \u7a0e\u52a1\u767b\u8bb0<\/p>\n<\/p>\n<\/div>\n<\/div>\n<p> <!-- \u6388\u6743\u8d44\u8d28\u56fe --><\/p>\n<h3 style=\"font-size:18px;font-weight:700;margin-bottom:16px;\" class=\"fade-in\">\ud83d\udcdc \u6388\u6743\u8d44\u8d28\u8bc1\u4e66<\/h3>\n<div class=\"cert-grid fade-in\">\n<div class=\"cert-item\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u65e5\u7acb\u5b89\u88c5\u7279\u9080\u6388\u6743.jpg\" alt=\"\u65e5\u7acb\u5b89\u88c5\u7279\u9080\u6388\u6743\" loading=\"lazy\"><\/p>\n<div class=\"cert-label\">\u65e5\u7acb\u5b89\u88c5\u7279\u9080\u6388\u6743<\/div>\n<\/p>\n<\/div>\n<div class=\"cert-item\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4f1f\u661f\u6388\u6743_210x300.jpg\" alt=\"\u4f1f\u661f\u6388\u6743\" loading=\"lazy\"><\/p>\n<div class=\"cert-label\">\u4f1f\u661f\u6388\u6743\u7ecf\u9500\u5546<\/div>\n<\/p>\n<\/div>\n<div class=\"cert-item\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/\u5fae\u4fe1\u56fe\u7247_20260429153324_59_93-scaled.png\" alt=\"\u65e5\u7acb\u94bb\u77f3\u670d\u52a1\u5546\u8ba4\u8bc1\" loading=\"lazy\"><\/p>\n<div class=\"cert-label\">\u65e5\u7acb\u94bb\u77f3\u670d\u52a1\u5546\u8ba4\u8bc1<\/div>\n<\/p>\n<\/div>\n<div class=\"cert-item\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-gold.jpg\" alt=\"\u91d1\u724c\u8d44\u8d28\" loading=\"lazy\"><\/p>\n<div class=\"cert-label\">\u91d1\u724c\u5b89\u88c5\u8d44\u8d28<\/div>\n<\/p>\n<\/div>\n<div class=\"cert-item\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg\" alt=\"\u7ecf\u9500\u5546\u8d44\u8d28\" loading=\"lazy\"><\/p>\n<div class=\"cert-label\">\u6388\u6743\u7ecf\u9500\u5546\u8d44\u8d28<\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- ===== Module 6: \u6848\u4f8b\u5206\u4eab ===== --><\/p>\n<section class=\"section\" id=\"cases\">\n<div class=\"section-header fade-in\">\n<div class=\"num\">6<\/div>\n<h2>\u6848\u4f8b\u5206\u4eab<\/h2>\n<p class=\"subtitle\">\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b \u00b7 \u7528\u6570\u636e\u8bf4\u8bdd<\/p>\n<div class=\"section-divider\"><\/div>\n<\/p>\n<\/div>\n<div class=\"case-cards\">\n<div class=\"case-card fade-in\">\n<div class=\"case-header\">\n<h4>\ud83c\udfe0 \u548c\u8d35\u5357\u5c71\u4e0a \u00b7 \u8f9b\u603b\u522b\u5885<\/h4>\n<div class=\"case-loc\">450\u33a1 \u4e24\u8054\u4f9b<\/div>\n<\/p>\n<\/div>\n<div class=\"case-body\">\n<div class=\"case-stat\"><span>\u91c7\u6696\u9762\u79ef<\/span><span class=\"val\">450\u33a1<\/span><\/div>\n<div class=\"case-stat\"><span>\u7cfb\u7edf\u7c7b\u578b<\/span><span class=\"val\">\u4e24\u8054\u4f9b<\/span><\/div>\n<div class=\"case-stat\"><span>\u5730\u6696\u6708\u8d39<\/span><span class=\"val\">\uff1c2000\u5143<\/span><\/div>\n<div class=\"case-stat\"><span>\u5bf9\u6bd4\u90bb\u5c45<\/span><span class=\"val\">\u770150%<\/span><\/div>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"case-card fade-in\">\n<div class=\"case-header\">\n<h4>\ud83c\udfe0 \u4fdd\u5229\u4e07\u79d1\u7fe1\u7fe0\u548c\u60a6 \u00b7 \u674e\u603b<\/h4>\n<div class=\"case-loc\">173\u33a1 \u53e0\u62fc\u51b7\u51dd\u7089\u65b9\u6848<\/div>\n<\/p>\n<\/div>\n<div class=\"case-body\">\n<div class=\"case-stat\"><span>\u91c7\u6696\u9762\u79ef<\/span><span class=\"val\">173\u33a1<\/span><\/div>\n<div class=\"case-stat\"><span>\u7cfb\u7edf\u7c7b\u578b<\/span><span class=\"val\">\u51b7\u51dd\u7089\u4e24\u8054\u4f9b<\/span><\/div>\n<div class=\"case-stat\"><span>\u6708\u71c3\u6c14\u8d39<\/span><span class=\"val\">~500\u5143<\/span><\/div>\n<div class=\"case-stat\"><span>\u5bf9\u6bd4\u4f20\u7edf<\/span><span class=\"val\">\u770160%<\/span><\/div>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"case-card fade-in\">\n<div class=\"case-header\">\n<h4>\ud83c\udfe0 \u9f99\u6e56\u5149\u5e74 \u00b7 \u5411\u673a\u957f<\/h4>\n<div class=\"case-loc\">\u5927\u5e73\u5c42\u6c34\u5885\u9002\u4e24\u8054\u4f9b+\u5929\u51c0\u65b0\u98ce<\/div>\n<\/p>\n<\/div>\n<div class=\"case-body\">\n<div class=\"case-stat\"><span>\u7cfb\u7edf\u7c7b\u578b<\/span><span class=\"val\">\u6c34\u5885\u9002+\u5929\u51c0\u65b0\u98ce<\/span><\/div>\n<div class=\"case-stat\"><span>\u5165\u4f4f\u53cd\u9988<\/span><span class=\"val\">\u96f6\u6295\u8bc9<\/span><\/div>\n<div class=\"case-stat\"><span>\u8212\u9002\u5ea6\u8bc4\u4ef7<\/span><span class=\"val\">\u4e94\u661f \u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/div>\n<div class=\"case-stat\"><span>\u8be6\u7ec6\u6848\u4f8b<\/span><span class=\"val\">\ud83d\udc49 1000+\u6848\u4f8b\u5e93<\/span><\/div>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"text-align:center;margin-top:32px;\" class=\"fade-in\">\n <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u67e5\u770b\u9f99\u8109\u6696\u901a1000+\u6848\u4f8b\u5e93 \u2192<\/a>\n <\/div>\n<p> <!-- \u84dd\u82b1\u6979 \u00b7 \u9b4f\u603b\u53cc\u6848\u4f8b --><\/p>\n<div class=\"fade-in\" style=\"margin-top:48px;background:#fff;border-radius:var(--lm-radius);box-shadow:var(--lm-shadow);padding:32px 24px;border-left:4px solid var(--lm-blue);\">\n<h3 style=\"font-size:20px;font-weight:800;color:var(--lm-blue);margin-bottom:4px;\">\u540c\u4e00\u4e2a\u4e1a\u4e3b\uff0c\u4e24\u4e2a\u5bb6\uff1a\u4ece\"\u80fd\u8017\u5c0f\u533a\u6700\u9ad8\"\u5230\"\u8282\u80fd\u5fc3\u91cc\u6709\u6570\"<\/h3>\n<p style=\"font-size:13px;color:var(--lm-gray-600);margin-bottom:20px;\">\u84dd\u82b1\u6979 \u00b7 \u8a89\u5cf0 \u53cc\u6848\u4f8b\u95ed\u73af<\/p>\n<div style=\"font-size:14px;line-height:1.9;color:var(--lm-gray-800);margin-bottom:20px;\">\n<p>\u9b4f\u603b\u84dd\u82b1\u6979\u65b0\u5b85\u91c7\u7528<strong>\u65e5\u7acb\u5c0a\u777f\u522b\u588512HP + \u745e\u7f8e\u53cc\u51b7\u51dd\u7089\u5730\u6696 + \u65b0\u98ce<\/strong>\uff0c\u8d39\u7528\u53ef\u63a7\uff1b\u8a89\u5cf0\u65e7\u5b85\u8bca\u65ad\u53d1\u73b0\u529f\u7387\u8d85\u914d\u3001\u56de\u8def\u4e0d\u8db3\u3001\u6c34\u529b\u5931\u8861\u7b49\u95ee\u9898\uff0c\u6539\u9020\u540e\u7528\u53cc\u51b7\u51dd\u7089+\u53bb\u8026\u7f50\u89e3\u51b3\uff0c\u5ba2\u6237\u4e3b\u52a8\u63a8\u8350\u3002\u5b8c\u6574\u6539\u9020\u524d\u540e\u5bf9\u6bd4\u56fe\u3001\u7cfb\u7edf\u8bca\u65ad\u5206\u6790\u3001\u5ba2\u6237\u539f\u8bdd\u7b49\u8be6\u60c5\u8bf7\u70b9\u51fb\u4e0b\u65b9\u94fe\u63a5\u67e5\u770b\u3002<\/p>\n<\/p>\n<\/div>\n<div style=\"background:var(--lm-gray-100);border-radius:var(--lm-radius-sm);padding:16px 20px;margin-bottom:20px;\">\n<div style=\"font-size:13px;line-height:2;color:var(--lm-gray-800);\">\n<p>\u2705 \u7cfb\u7edf\u56db\u8981\u7d20\uff1a\u70ed\u6e90\u2192\u8f93\u914d\u2192\u672b\u7aef\u2192\u63a7\u5236\u7cbe\u786e\u5339\u914d<\/p>\n<p>\u2705 \u7cbe\u5de56+2\u5b89\u88c5\u6807\u51c6\uff0c\u5ba2\u6237\u7b7e\u5b57\u6743\u5168\u7a0b\u89c1\u8bc1<\/p>\n<p>\u2705 20\u5e74\u603b\u8d26\u6bd4\u521d\u6295\u8d44\u66f4\u91cd\u8981\u2014\u2014W\u603b\u4e3b\u52a8\u9009\u62e9\u53cc\u51b7\u51dd\u7089<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div style=\"text-align:center;\">\n <a href=\"https:\/\/longmai-nt.com\/?page_id=378\" target=\"_blank\" class=\"product-link\">\ud83d\udccb \u67e5\u770b\u5b8c\u6574\u6848\u4f8b\u6587\u7ae0\uff08\u542b\u6539\u9020\u524d\u540e\u5bf9\u6bd4\u56fe\uff09 \u2192<\/a>\n <\/div>\n<\/p>\n<\/div>\n<\/section>\n<p><!-- ===== Footer ===== --><\/p>\n<footer class=\"page-footer\">\n<h3>\u9f99\u8109\u6696\u901a<\/h3>\n<p>\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e24\u8054\u4f9b | \u4e13\u6ce8 \u00b7 \u53ef\u89c6\u5316\u670d\u52a1<\/p>\n<p style=\"margin-top:8px;\">\ud83d\udcde \u9884\u7ea6\u54a8\u8be2 \u00b7 \u4e0a\u95e8\u8bca\u65ad \u00b7 \u514d\u8d39\u51fa\u65b9\u6848<\/p>\n<p style=\"margin-top:16px;font-size:12px;opacity:0.5;\">\u00a9 2026 \u9f99\u8109\u6696\u901a \u00b7 \u4fdd\u7559\u6240\u6709\u6743\u5229<\/p>\n<\/footer>\n<p><!-- ===== JavaScript ===== --><br \/>\n<script>\n\/\/ === WordPress Admin Bar Detection ===\nfunction adjustNavForAdminBar() {\n var adminBar = document.getElementById('wpadminbar');\n var stickyNav = document.getElementById('stickyNav');\n if (adminBar && stickyNav) {\n var offset = adminBar.offsetHeight;\n stickyNav.style.top = offset + 'px';\n document.documentElement.style.scrollPaddingTop = (offset + 56 + 14) + 'px';\n }\n}\nwindow.addEventListener('load', adjustNavForAdminBar);\nwindow.addEventListener('resize', adjustNavForAdminBar);<\/p>\n<p>\/\/ === Sticky Nav Scroll Effect ===\nconst nav = document.getElementById('stickyNav');\nconst navLinks = document.querySelectorAll('.nav-link');\nconst sections = document.querySelectorAll('section[id]');<\/p>\n<p>window.addEventListener('scroll', () => {\n \/\/ Nav shadow\n nav.classList.toggle('scrolled', window.scrollY > 10);<\/p>\n<p> \/\/ Dynamic scroll offset (admin bar + nav height + margin)\n var adminBar = document.getElementById('wpadminbar');\n var adminOffset = adminBar ? adminBar.offsetHeight : 0;\n var scrollOffset = adminOffset + 56 + 14;<\/p>\n<p> \/\/ Active section highlight\n let current = '';\n sections.forEach(section => {\n const top = section.offsetTop - scrollOffset;\n if (window.scrollY >= top) current = section.id;\n });\n navLinks.forEach(link => {\n link.classList.toggle('active', link.getAttribute('data-section') === current);\n });\n});<\/p>\n<p>\/\/ === Slider System ===\nconst sliders = {};<\/p>\n<p>function initSlider(name, trackId, dotsId) {\n const track = document.getElementById(trackId);\n const dotsEl = document.getElementById(dotsId);\n const imgs = track.querySelectorAll('img');\n const count = imgs.length;<\/p>\n<p> \/\/ Create dots\n for (let i = 0; i < count; i++) {\n const dot = document.createElement('button');\n dot.className = 'slider-dot' + (i === 0 ? ' active' : '');\n dot.onclick = () => goToSlide(name, i);\n dotsEl.appendChild(dot);\n }<\/p>\n<p> sliders[name] = { track, dotsEl, current: 0, count, autoTimer: null };<\/p>\n<p> \/\/ Auto-slide every 5s\n startAutoSlide(name);\n}<\/p>\n<p>function goToSlide(name, index) {\n const s = sliders[name];\n s.current = index;\n s.track.style.transform = `translateX(-${index * 100}%)`;\n const dots = s.dotsEl.querySelectorAll('.slider-dot');\n dots.forEach((d, i) => d.classList.toggle('active', i === index));\n}<\/p>\n<p>function slideNext(name) {\n const s = sliders[name];\n goToSlide(name, (s.current + 1) % s.count);\n resetAutoSlide(name);\n}<\/p>\n<p>function slidePrev(name) {\n const s = sliders[name];\n goToSlide(name, (s.current - 1 + s.count) % s.count);\n resetAutoSlide(name);\n}<\/p>\n<p>function startAutoSlide(name) {\n sliders[name].autoTimer = setInterval(() => slideNext(name), 5000);\n}<\/p>\n<p>function resetAutoSlide(name) {\n clearInterval(sliders[name].autoTimer);\n startAutoSlide(name);\n}<\/p>\n<p>\/\/ Init sliders\ninitSlider('ac', 'acTrack', 'acDots');\ninitSlider('install', 'installTrack', 'installDots');\ninitSlider('vam', 'vamTrack', 'vamDots');\ninitSlider('suituku', 'suitukuTrack', 'suitukuDots');<\/p>\n<p>\/\/ Touch swipe support\ndocument.querySelectorAll('.slider-container').forEach(container => {\n let startX = 0;\n container.addEventListener('touchstart', e => { startX = e.touches[0].clientX; }, { passive: true });\n container.addEventListener('touchend', e => {\n const diff = startX - e.changedTouches[0].clientX;\n const name = container.id === 'acSlider' ? 'ac' : 'install';\n if (Math.abs(diff) > 50) {\n diff > 0 ? slideNext(name) : slidePrev(name);\n }\n }, { passive: true });\n});<\/p>\n<p>\/\/ === Accordion ===\nfunction toggleAccordion() {\n const trigger = document.getElementById('boilerTrigger');\n const content = document.getElementById('boilerContent');\n trigger.classList.toggle('open');\n content.classList.toggle('open');\n}<\/p>\n<p>function toggleCostAccordion() {\n const trigger = document.getElementById('costTrigger');\n const content = document.getElementById('costContent');\n trigger.classList.toggle('open');\n content.classList.toggle('open');\n}<\/p>\n<p>\/\/ === Calculator ===\nconst houseTypes = {\n 'A': { heatingArea: 66, acPrice: 22720, label: '99\u33a1\u6e05\u6c34\u623f' },\n 'B': { heatingArea: 66, acPrice: 19800, label: '88\u33a1\u7cbe\u88c5\u623f' },\n 'C': { heatingArea: 66, acPrice: 27500, label: '120\u33a1\u7cbe\u88c5\u623f' },\n 'custom': { heatingArea: 66, acPrice: 22720, label: '\u81ea\u5b9a\u4e49' }\n};\nconst boilerData = {\n 'A': { price: 5600, name: '\u535a\u4e16 G6100W' },\n 'B': { price: 5800, name: '\u83f2\u65af\u66fc A1JE' },\n 'C': { price: 4666, name: '\u66fc\u745e\u5fb7 HI.PRO' }\n};\nconst heatingData = {\n 'standard': { ppm: 99, name: '\u5e02\u573a\u901a\u914d' },\n 'energy': { ppm: 169, name: '\u8282\u80fd\u5957\u9910' }\n};<\/p>\n<p>function onHouseTypeChange() {\n const type = document.getElementById('calcHouseType').value;\n const areaInput = document.getElementById('calcHeatingArea');\n if (type !== 'custom' && houseTypes[type]) {\n areaInput.value = houseTypes[type].heatingArea;\n }\n calcUpdate();\n}<\/p>\n<p>function calcUpdate() {\n const type = document.getElementById('calcHouseType').value;\n const area = parseFloat(document.getElementById('calcHeatingArea').value) || 0;\n const boilerKey = document.getElementById('calcBoiler').value;\n const modeKey = document.getElementById('calcHeatingMode').value;<\/p>\n<p> const acPrice = (type !== 'custom' && houseTypes[type]) ? houseTypes[type].acPrice : 22720;\n const boiler = boilerData[boilerKey];\n const mode = heatingData[modeKey];\n const heating = Math.round(area * mode.ppm);\n const total = acPrice + heating + boiler.price - 500;<\/p>\n<p> document.getElementById('calcTotal').innerHTML = '\u00a5' + total.toLocaleString() + '<small> \u8d77<\/small>';\n document.getElementById('bdAC').textContent = '\u00a5' + acPrice.toLocaleString();\n document.getElementById('bdArea').textContent = area;\n document.getElementById('bdMode').textContent = mode.name;\n document.getElementById('bdHeating').textContent = '\u00a5' + heating.toLocaleString();\n document.getElementById('bdBoiler').textContent = boiler.name;\n document.getElementById('bdBoilerPrice').textContent = '\u00a5' + boiler.price.toLocaleString();\n document.getElementById('bdTotal').textContent = '\u00a5' + total.toLocaleString();\n}<\/p>\n<p>\/\/ Init\ncalcUpdate();<\/p>\n<p>\/\/ === Scroll Fade-in Animation ===\nconst fadeEls = document.querySelectorAll('.fade-in');\nconst observer = new IntersectionObserver((entries) => {\n entries.forEach(entry => {\n if (entry.isIntersecting) {\n entry.target.classList.add('visible');\n }\n });\n}, { threshold: 0.1, rootMargin: '0px 0px -40px 0px' });<\/p>\n<p>fadeEls.forEach(el => observer.observe(el));<\/p>\n<p>function toggleShuxiangQuote() {\n var c = document.getElementById(\"shuxiangQuoteContent\");\n var btn = document.getElementById(\"shuxiangQuoteTrigger\");\n var isOpen = c.classList.contains(\"open\");\n if (isOpen) {\n c.classList.remove(\"open\");\n btn.classList.remove(\"open\");\n } else {\n c.classList.add(\"open\");\n btn.classList.add(\"open\");\n }\n}<\/p>\n<p>function toggleDinuanBikeng() {\n var c = document.getElementById(\"dinuanBikengContent\");\n var btn = document.getElementById(\"dinuanBikengTrigger\");\n var isOpen = c.classList.contains(\"open\");\n if (isOpen) {\n c.classList.remove(\"open\");\n btn.classList.remove(\"open\");\n } else {\n c.classList.add(\"open\");\n btn.classList.add(\"open\");\n }\n}<\/p>\n<p>function toggleHltVsMidea() {\n var c = document.getElementById(\"hltVsMideaContent\");\n var btn = document.getElementById(\"hltVsMideaTrigger\");\n var isOpen = c.classList.contains(\"open\");\n if (isOpen) {\n c.classList.remove(\"open\");\n btn.classList.remove(\"open\");\n } else {\n c.classList.add(\"open\");\n btn.classList.add(\"open\");\n }\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\ud83d\udd25 \u9f99\u8109\u6696\u901a\u00b7\u56e2\u8d2d \u9700\u6c42\u5206\u6790 \u4ea7\u54c1\u53c2\u6570  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4002","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=4002\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\ud83d\udd25 \u9f99\u8109\u6696\u901a\u00b7\u56e2\u8d2d \u9700\u6c42\u5206\u6790 \u4ea7\u54c1\u53c2\u6570 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=4002\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-14T11:29:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002\",\"name\":\"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p01-04.jpeg\",\"datePublished\":\"2026-06-19T09:29:44+00:00\",\"dateModified\":\"2026-11-14T11:29:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p01-04.jpeg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p01-04.jpeg\",\"width\":258,\"height\":374},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4002#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=4002","og_locale":"zh_CN","og_type":"article","og_title":"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910 - \u9f99\u8109\u6696\u901a","og_description":"\ud83d\udd25 \u9f99\u8109\u6696\u901a\u00b7\u56e2\u8d2d \u9700\u6c42\u5206\u6790 \u4ea7\u54c1\u53c2\u6570 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=4002","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-14T11:29:46+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"13 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=4002","url":"https:\/\/longmai-nt.com\/?page_id=4002","name":"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=4002#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=4002#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg","datePublished":"2026-06-19T09:29:44+00:00","dateModified":"2026-11-14T11:29:46+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=4002#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=4002"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=4002#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg","width":258,"height":374},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=4002#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5149\u534e\u5929\u73ba*\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u56e2\u8d2d\u4e13\u4eab\u5957\u9910"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4002","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4002"}],"version-history":[{"count":17,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4002\/revisions"}],"predecessor-version":[{"id":20567,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4002\/revisions\/20567"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4002"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}