{"id":4257,"date":"2026-06-22T23:44:40","date_gmt":"2026-06-22T15:44:40","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=4257"},"modified":"2026-06-22T23:44:40","modified_gmt":"2026-06-22T15:44:40","slug":"%e8%94%a1%e5%85%88%e7%94%9f%e6%96%b9%e6%a1%88%e5%89%8d%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=4257","title":{"rendered":"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66"},"content":{"rendered":"\n\n<style>\n  * { box-sizing: border-box; margin: 0; padding: 0; }\n  body { font-family: \"Microsoft YaHei\", \"PingFang SC\", sans-serif; background: #f5f5f5; color: #333; }\n  .page { max-width: 900px; margin: 0 auto; background: #fff; }\n  .cover { background: linear-gradient(135deg, #1a4e8a 0%, #2a7ab5 60%, #3a9ad5 100%);\n    color: #fff; padding: 60px 50px; text-align: center; position: relative; overflow: hidden; }\n  .cover::before { content: \"\"; position: absolute; top: -40px; right: -40px; width: 200px; height: 200px;\n    border-radius: 50%; background: rgba(255,255,255,0.06); }\n  .cover::after { content: \"\"; position: absolute; bottom: -60px; left: -60px; width: 260px; height: 260px;\n    border-radius: 50%; background: rgba(255,255,255,0.04); }\n  .cover-logo { font-size: 13px; letter-spacing: 2px; opacity: 0.7; margin-bottom: 30px; }\n  .cover-title { font-size: 28px; font-weight: bold; margin-bottom: 10px; letter-spacing: 4px; }\n  .cover-sub { font-size: 15px; opacity: 0.85; margin-bottom: 40px; }\n  .cover-info { display: inline-block; text-align: left; background: rgba(255,255,255,0.12);\n    border-radius: 8px; padding: 20px 35px; backdrop-filter: blur(4px); }\n  .cover-info div { font-size: 14px; line-height: 2; }\n  .cover-info span { opacity: 0.7; display: inline-block; width: 80px; }\n  .cover-date { margin-top: 40px; font-size: 13px; opacity: 0.6; }\n  .section { padding: 40px 50px; border-bottom: 1px solid #eee; }\n  .section:last-child { border-bottom: none; }\n  .sec-title { font-size: 18px; font-weight: bold; color: #1a4e8a; margin-bottom: 20px;\n    padding-left: 12px; border-left: 4px solid #2a7ab5; line-height: 1.4; }\n  .sec-body { font-size: 14px; line-height: 1.9; color: #444; }\n  .sec-body p { margin-bottom: 12px; }\n  table { width: 100%; border-collapse: collapse; margin: 16px 0; font-size: 13.5px; }\n  th { background: #1a4e8a; color: #fff; padding: 10px 12px; text-align: center; font-weight: normal; }\n  td { padding: 9px 12px; border-bottom: 1px solid #e8e8e8; text-align: center; }\n  tr:nth-child(even) td { background: #f8fafc; }\n  tr:hover td { background: #eef4fb; }\n  .card { background: #f0f7ff; border-left: 4px solid #2a7ab5; padding: 18px 22px;\n    border-radius: 0 8px 8px 0; margin: 18px 0; }\n  .card-title { font-weight: bold; color: #1a4e8a; margin-bottom: 8px; font-size: 15px; }\n  .conclusion { background: linear-gradient(135deg, #e8f5e9, #f1f8e9); border: 1px solid #a5d6a7;\n    border-radius: 8px; padding: 22px 26px; margin: 20px 0; }\n  .conclusion.warn { background: linear-gradient(135deg, #fff8e1, #fffde7); border-color: #ffd54f; }\n  .conclusion.bad { background: linear-gradient(135deg, #fff3e0, #fbe9e7); border-color: #ffab91; }\n  .conclusion-title { font-size: 15px; font-weight: bold; margin-bottom: 10px; color: #2e7d32; }\n  .conclusion.warn .conclusion-title { color: #f57f17; }\n  .conclusion.bad .conclusion-title { color: #d84315; }\n  .tag { display: inline-block; padding: 2px 10px; border-radius: 10px; font-size: 12px;\n    font-weight: bold; margin-left: 6px; vertical-align: middle; }\n  .tag-green { background: #e8f5e9; color: #2e7d32; }\n  .tag-orange { background: #fff3e0; color: #e65100; }\n  .tag-red { background: #ffebee; color: #c62828; }\n  .tag-blue { background: #e3f2fd; color: #1565c0; }\n  .footer { background: #1a4e8a; color: rgba(255,255,255,0.7); text-align: center;\n    padding: 22px; font-size: 12px; line-height: 1.8; }\n  .room-layout { background: #fafafa; border: 1px solid #ddd; border-radius: 8px;\n    padding: 20px; margin: 18px 0; text-align: center; }\n  .room-layout svg { max-width: 100%; height: auto; }\n  .calc-step { background: #f8fafc; border: 1px dashed #c5cae9; border-radius: 6px;\n    padding: 14px 18px; margin: 12px 0; font-size: 13.5px; }\n  .calc-step .step-num { display: inline-block; width: 22px; height: 22px; background: #2a7ab5;\n    color: #fff; border-radius: 50%; text-align: center; line-height: 22px; font-size: 12px;\n    margin-right: 8px; }\n  .equip-summary { display: flex; gap: 16px; flex-wrap: wrap; margin: 18px 0; }\n  .equip-box { flex: 1; min-width: 200px; border: 1px solid #ddd; border-radius: 8px;\n    padding: 18px; background: #fafafa; }\n  .equip-box h4 { color: #1a4e8a; margin-bottom: 10px; font-size: 14px; }\n  .equip-box p { font-size: 13px; color: #666; line-height: 1.7; }\n  .std-ref { background: #e8eaf6; border-left: 3px solid #3f51b5; padding: 12px 16px;\n    margin: 14px 0; font-size: 13px; color: #333; line-height: 1.8; }\n  .std-ref b { color: #3f51b5; }\n  .plan-compare { display: flex; gap: 20px; margin: 20px 0; flex-wrap: wrap; }\n  .plan-box { flex: 1; min-width: 280px; border: 2px solid #ddd; border-radius: 10px;\n    padding: 20px; background: #fafafa; position: relative; }\n  .plan-box.recommend { border-color: #2a7ab5; background: #f0f7ff; }\n  .plan-badge { position: absolute; top: -12px; left: 20px; background: #2a7ab5; color: #fff;\n    padding: 3px 14px; border-radius: 12px; font-size: 12px; font-weight: bold; }\n  .plan-badge.alt { background: #999; }\n  .plan-box h4 { color: #1a4e8a; margin-bottom: 14px; font-size: 15px; }\n  .plan-box p { font-size: 13px; color: #555; line-height: 1.8; }\n  .plan-box .plan-item { padding: 6px 0; border-bottom: 1px dotted #ddd; font-size: 13px; }\n  .plan-box .plan-item:last-child { border-bottom: none; }\n  .dim-table th { background: #2a7ab5; }\n  .highlight-num { color: #d84315; font-weight: bold; font-size: 15px; }\n<\/style>\n\n<div class=\"page\">\n\n  <!-- \u5c01\u9762 -->\n  <div class=\"cover\">\n    <div class=\"cover-logo\">LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n    <div class=\"cover-title\">\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u524d\u4e66<\/div>\n    <div class=\"cover-sub\">\u590d\u5730\u91d1\u878d\u5c9b \u00b7 \u8521\u5148\u751f\u6237\u578b\u5b9a\u5236\u65b9\u6848<\/div>\n    <div class=\"cover-info\">\n      <div><span>\u9879\u76ee\u540d\u79f0<\/span>\uff1a\u590d\u5730\u91d1\u878d\u5c9b<\/div>\n      <div><span>\u5ba2\u6237\u59d3\u540d<\/span>\uff1a\u8521\u5148\u751f<\/div>\n      <div><span>\u5236\u51b7\u9762\u79ef<\/span>\uff1a120 \u33a1\uff08\u5ba2\u9910\u538559\u33a1 + \u4e3b\u536722\u33a1 + \u513f\u7ae5\u623f\u540413\u33a1 + \u4e66\u623f10\u33a1\uff09<\/div>\n      <div><span>\u5e38\u4f4f\u4eba\u6570<\/span>\uff1a4 \u4eba<\/div>\n      <div><span>\u65b9\u6848\u7c7b\u578b<\/span>\uff1a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696<\/div>\n    <\/div>\n    <div class=\"cover-date\">\u65b9\u6848\u65e5\u671f\uff1a2026\u5e746\u6708<\/div>\n    <div style=\"margin-top:14px;font-size:12px;opacity:0.85;\">\n      <a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" style=\"color:#fff;text-decoration:underline;\" target=\"_blank\">\ud83d\udca1 \u70b9\u51fb\u4e86\u89e3\u65e5\u7acb\u8212\u4eabEX\u7cfb\u5217\u8be6\u7ec6\u53c2\u6570<\/a>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u4e00\u7ae0\uff1a\u8bbe\u8ba1\u4f9d\u636e -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u4e00\u3001\u8bbe\u8ba1\u4f9d\u636e\u4e0e\u6280\u672f\u6807\u51c6<\/div>\n    <div class=\"sec-body\">\n      <table>\n        <tr>\n          <th width=\"20%\">\u6807\u51c6\/\u89c4\u8303<\/th>\n          <th width=\"35%\">\u540d\u79f0<\/th>\n          <th>\u9002\u7528\u5185\u5bb9<\/th>\n        <\/tr>\n        <tr>\n          <td>GB 50736-2012<\/td>\n          <td>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td>\n          <td>\u51b7\u8d1f\u8377\u6307\u6807\u3001\u5ba4\u5185\u8bbe\u8ba1\u53c2\u6570<\/td>\n        <\/tr>\n        <tr>\n          <td>GB\/T 18837<\/td>\n          <td>\u300a\u591a\u8054\u5f0f\u7a7a\u8c03\uff08\u70ed\u6cf5\uff09\u673a\u7ec4\u300b<\/td>\n          <td>\u8bbe\u5907\u6027\u80fd\u6d4b\u8bd5\u6807\u51c6<\/td>\n        <\/tr>\n        <tr>\n          <td>\u2014<\/td>\n          <td>\u9f99\u8109\u6696\u901a\u6280\u80fd\u5e93 \u00b7 \u6c1f\u7cfb\u7edf\u767d\u76ae\u4e66 V2.0<\/td>\n          <td>\u9009\u578b\u89c4\u5219\u3001\u8d85\u914d\u7387\u63a7\u5236\u3001\u538b\u7f29\u673a\u9009\u578b<\/td>\n        <\/tr>\n      <\/table>\n\n      <div class=\"std-ref\">\n        <b>GB 50736-2012 \u51b7\u8d1f\u8377\u6307\u6807\u89c4\u5b9a\uff08\u9ad8\u5c42\u4f4f\u5b85\uff09\uff1a<\/b><br>\n        \u590f\u70ed\u51ac\u6696\u5730\u533a\u9ad8\u5c42\u4f4f\u5b85\uff0c\u7a7a\u8c03\u51b7\u8d1f\u8377\u6307\u6807\uff08\u6309<strong>\u5efa\u7b51\u9762\u79ef<\/strong>\uff09\u4e3a <strong>80\uff5e120 W\/\u33a1<\/strong>\u3002<br>\n        \u6ce8\uff1a\u6b64\u4e3a\"\u5efa\u7b51\u9762\u79ef\u51b7\u6307\u6807\"\uff0c\u5373\u603b\u5efa\u7b51\u9762\u79ef\u00d7\u6307\u6807=\u603b\u51b7\u8d1f\u8377\u3002\u623f\u95f4\u5185\u673a\u9009\u578b\u65f6\uff0c\u9700\u6309\u5404\u623f\u95f4\u529f\u80fd\u3001\u671d\u5411\u3001\u7a97\u5899\u6bd4\u7b49\u56e0\u7d20\u5728\u6307\u6807\u8303\u56f4\u5185\u53d6\u503c\u3002\n      <\/div>\n\n      <div class=\"card\">\n        <div class=\"card-title\">\u2606 \u6280\u80fd\u5e93\u6838\u5fc3\u9009\u578b\u89c4\u5219\uff08\u6c1f\u7cfb\u7edf\u767d\u76ae\u4e66 V2.0\uff09<\/div>\n        <p>\u2460 <b>\u8d85\u914d\u7387<\/b>\uff1a90%\uff5e110% \u4e3a\u7406\u60f3\u533a\u95f4\uff1b110%\uff5e130% \u4e3a\u5141\u8bb8\u533a\u95f4\uff1b&gt;130% \u8fc7\u9ad8\uff1b<br>\n        \u2461 <b>\u538b\u7f29\u673a\u9009\u578b<\/b>\uff1a\u5e38\u5f001~2\u53f0\u3001\u8ffd\u6c42\u6027\u4ef7\u6bd4 \u2192 \u53cc\u8f6c\u5b50\uff1b\u5e38\u5f003\u53f0\u4ee5\u4e0a \u2192 \u6da1\u65cb\uff1b<br>\n        \u2462 <b>\u6309\u9762\u79ef\u9009\u5916\u673a<\/b>\uff1a100~140\u33a1 \u2192 \u63a8\u8350\u5236\u51b7\u91cf12~14kW\uff08\u5bf9\u5e94125~160\u578b\uff09\uff1b<br>\n        \u2463 <b>\u5185\u673a\u5e03\u5c40<\/b>\uff1a\u4f18\u5148\"\u4fa7\u51fa\u4e0b\u56de\"\uff0c\u907f\u514d\u51fa\u98ce\u53e3\u76f4\u5bf9\u5e8a\/\u6c99\u53d1\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u4e8c\u7ae0\uff1a\u9879\u76ee\u6982\u51b5 -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u4e8c\u3001\u9879\u76ee\u6982\u51b5\u4e0e\u9700\u6c42\u5206\u6790<\/div>\n    <div class=\"sec-body\">\n      <table>\n        <tr><th>\u9879\u76ee\u4fe1\u606f<\/th><th>\u53c2\u6570<\/th><\/tr>\n        <tr><td>\u6237\u578b<\/td><td>\u56db\u5ba4\u4e24\u5385\uff08\u5ba2\u9910\u5385 + \u4e3b\u5367 + \u513f\u7ae5\u623f\u00d72 + \u4e66\u623f\uff09<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u603b\u9762\u79ef<\/td><td>\u7ea6 120 \u33a1<\/td><\/tr>\n        <tr><td>\u5404\u623f\u95f4\u9762\u79ef<\/td><td>\u5ba2\u9910\u5385 59\u33a1 \/ \u4e3b\u5367 22\u33a1 \/ \u513f\u7ae5\u623f\u4e00 13\u33a1 \/ \u513f\u7ae5\u623f\u4e8c 13\u33a1 \/ \u4e66\u623f 10\u33a1<\/td><\/tr>\n        <tr><td>\u5e38\u4f4f\u4eba\u53e3<\/td><td>4 \u4eba<\/td><\/tr>\n        <tr><td>\u540c\u5f00\u7279\u5f81<\/td><td>\u7a7a\u8c03\u540c\u5f00\u7387\u4e0d\u9ad8\uff0c\u591c\u95f4\u4e3b\u8981\u5f00\u542f\u5ba2\u5385+\u4e3b\u5367<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a\u504f\u597d<\/td><td>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff08\u5e97\u94fa\u539f\u6c9f\u901a\u7ed3\u8bba\uff0c\u4e0e\u4f7f\u7528\u7279\u5f81\u543b\u5408\uff09<\/td><\/tr>\n        <tr><td>\u5730\u6696\u9700\u6c42<\/td><td>\u8521\u5148\u751f\u660e\u786e\u9700\u8981\u505a\u5730\u6696<\/td><\/tr>\n      <\/table>\n\n      <div class=\"room-layout\">\n        <svg viewBox=\"0 0 600 320\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:600px\">\n          <rect x=\"0\" y=\"0\" width=\"600\" height=\"320\" fill=\"#f8fafc\" stroke=\"#ccc\" stroke-width=\"1\"\/>\n          <rect x=\"20\" y=\"20\" width=\"340\" height=\"180\" fill=\"#e3f2fd\" stroke=\"#1a4e8a\" stroke-width=\"2\" rx=\"4\"\/>\n          <text x=\"190\" y=\"105\" text-anchor=\"middle\" font-size=\"14\" fill=\"#1a4e8a\" font-weight=\"bold\">\u5ba2\u9910\u5385<\/text>\n          <text x=\"190\" y=\"125\" text-anchor=\"middle\" font-size=\"12\" fill=\"#555\">59 \u33a1<\/text>\n          <rect x=\"380\" y=\"20\" width=\"200\" height=\"130\" fill=\"#e8f5e9\" stroke=\"#2e7d32\" stroke-width=\"2\" rx=\"4\"\/>\n          <text x=\"480\" y=\"85\" text-anchor=\"middle\" font-size=\"13\" fill=\"#2e7d32\" font-weight=\"bold\">\u4e3b\u5367<\/text>\n          <text x=\"480\" y=\"105\" text-anchor=\"middle\" font-size=\"11\" fill=\"#555\">22 \u33a1<\/text>\n          <rect x=\"380\" y=\"165\" width=\"95\" height=\"110\" fill=\"#fff3e0\" stroke=\"#e65100\" stroke-width=\"2\" rx=\"4\"\/>\n          <text x=\"427\" y=\"225\" text-anchor=\"middle\" font-size=\"11\" fill=\"#e65100\" font-weight=\"bold\">\u513f\u7ae5\u623f\u4e00<\/text>\n          <text x=\"427\" y=\"242\" text-anchor=\"middle\" font-size=\"10\" fill=\"#555\">13 \u33a1<\/text>\n          <rect x=\"485\" y=\"165\" width=\"95\" height=\"110\" fill=\"#fff3e0\" stroke=\"#e65100\" stroke-width=\"2\" rx=\"4\"\/>\n          <text x=\"532\" y=\"225\" text-anchor=\"middle\" font-size=\"11\" fill=\"#e65100\" font-weight=\"bold\">\u513f\u7ae5\u623f\u4e8c<\/text>\n          <text x=\"532\" y=\"242\" text-anchor=\"middle\" font-size=\"10\" fill=\"#555\">13 \u33a1<\/text>\n          <rect x=\"20\" y=\"215\" width=\"150\" height=\"85\" fill=\"#f3e5f5\" stroke=\"#7b1fa2\" stroke-width=\"2\" rx=\"4\"\/>\n          <text x=\"95\" y=\"260\" text-anchor=\"middle\" font-size=\"12\" fill=\"#7b1fa2\" font-weight=\"bold\">\u4e66\u623f<\/text>\n          <text x=\"95\" y=\"278\" text-anchor=\"middle\" font-size=\"10\" fill=\"#555\">10 \u33a1<\/text>\n          <text x=\"190\" y=\"215\" text-anchor=\"middle\" font-size=\"10\" fill=\"#999\">\u8fc7\u9053\u542b\u4e8e\u5ba2\u9910\u5385\u9762\u79ef\u5185<\/text>\n          <rect x=\"560\" y=\"260\" width=\"10\" height=\"10\" fill=\"#e3f2fd\" stroke=\"#1a4e8a\"\/>\n          <text x=\"575\" y=\"269\" font-size=\"9\" fill=\"#666\">\u5ba2\u9910\u5385<\/text>\n          <rect x=\"560\" y=\"274\" width=\"10\" height=\"10\" fill=\"#e8f5e9\" stroke=\"#2e7d32\"\/>\n          <text x=\"575\" y=\"283\" font-size=\"9\" fill=\"#666\">\u5367\u5ba4<\/text>\n          <rect x=\"560\" y=\"288\" width=\"10\" height=\"10\" fill=\"#fff3e0\" stroke=\"#e65100\"\/>\n          <text x=\"575\" y=\"297\" font-size=\"9\" fill=\"#666\">\u513f\u7ae5\u623f<\/text>\n        <\/svg>\n        <div style=\"font-size:12px;color:#999;margin-top:8px;\">\u6237\u578b\u9762\u79ef\u5206\u5e03\u793a\u610f\u56fe<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u4e09\u7ae0\uff1a\u9010\u623f\u95f4\u8d1f\u8377\u8ba1\u7b97 -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u4e09\u3001\u9010\u623f\u95f4\u8d1f\u8377\u8ba1\u7b97\uff08GB 50736-2012 \u51b7\u6307\u6807\u6cd5\uff09<\/div>\n    <div class=\"sec-body\">\n      <div class=\"std-ref\">\n        <b>\u8ba1\u7b97\u4f9d\u636e\uff1a<\/b>GB 50736-2012 \u89c4\u5b9a\uff0c\u590f\u70ed\u51ac\u6696\u5730\u533a<strong>\u9ad8\u5c42\u4f4f\u5b85<\/strong>\u7a7a\u8c03\u51b7\u8d1f\u8377\u6307\u6807\uff08\u6309\u5efa\u7b51\u9762\u79ef\uff09\u4e3a\n        <strong>80\uff5e120 W\/\u33a1<\/strong>\u3002\u672c\u5de5\u7a0b\u5236\u51b7\u9762\u79ef120\u33a1\uff0c\u6309\u6307\u6807\u4e2d\u4e0a\u9650 <strong>110 W\/\u33a1<\/strong> \u8ba1\u7b97\u603b\u51b7\u8d1f\u8377\uff0c\n        \u518d\u6309\u5404\u623f\u95f4\u9762\u79ef\u5360\u6bd4\u5206\u914d\uff0c\u5e76\u7ed3\u5408\u623f\u95f4\u529f\u80fd\u9002\u5f53\u4fee\u6b63\u3002\n      <\/div>\n\n      <div class=\"calc-step\">\n        <span class=\"step-num\">1<\/span><b>\u603b\u51b7\u8d1f\u8377\u8ba1\u7b97<\/b>\uff1a\u5236\u51b7\u9762\u79ef 120\u33a1 \u00d7 110 W\/\u33a1 = <b>13.2 kW<\/b>\uff08\u603b\u5236\u51b7\u9700\u6c42\uff09\n      <\/div>\n      <div class=\"calc-step\">\n        <span class=\"step-num\">2<\/span><b>\u5404\u623f\u95f4\u51b7\u8d1f\u8377\u5206\u914d<\/b>\uff1a\u6309\u623f\u95f4\u9762\u79ef\u5360\u6bd4\u5206\u914d\u603b\u8d1f\u8377\uff0c\u5ba2\u9910\u5385\u56e0\u4eba\u5458\u5bc6\u5ea6\u5927\u3001\u592a\u9633\u8f90\u5c04\u5f3a\uff0c\u53d6\u6307\u6807\u4e0a\u9650\uff1b\u5367\u5ba4\u53d6\u4e2d\u4e0a\u9650\uff1b\u4e66\u623f\u53d6\u4e2d\u503c\u3002\n      <\/div>\n      <div class=\"calc-step\">\n        <span class=\"step-num\">3<\/span><b>\u5185\u673a\u9009\u578b\u539f\u5219<\/b>\uff1a\u5185\u673a\u989d\u5b9a\u5236\u51b7\u91cf \u2265 \u623f\u95f4\u8ba1\u7b97\u51b7\u8d1f\u8377\uff0c\u5e76\u9075\u5faa\"\u5c31\u5927\u4e0d\u5c31\u5c0f\"\u539f\u5219\uff0c\u786e\u4fdd\u6781\u7aef\u5929\u6c14\u4e0b\u5236\u51b7\u4fdd\u969c\u80fd\u529b\u3002\n      <\/div>\n\n      <table>\n        <tr>\n          <th>\u623f\u95f4<\/th>\n          <th>\u9762\u79ef(\u33a1)<\/th>\n          <th>\u91c7\u7528\u6307\u6807(W\/\u33a1)<\/th>\n          <th>\u8ba1\u7b97\u51b7\u8d1f\u8377(kW)<\/th>\n          <th>\u63a8\u8350\u5185\u673a<\/th>\n          <th>\u5185\u673a\u5236\u51b7\u91cf(kW)<\/th>\n          <th>\u5339\u914d\u8bc4\u4ef7<\/th>\n        <\/tr>\n        <tr>\n          <td><b>\u5ba2\u9910\u5385<\/b><\/td>\n          <td>59<\/td>\n          <td>120\uff08\u4e0a\u9650\uff09<\/td>\n          <td><b>7.08<\/b><\/td>\n          <td>\u89c1\u7b2c\u56db\u7ae0\u4e13\u9879\u5206\u6790<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e3b\u5367<\/td>\n          <td>22<\/td>\n          <td>110<\/td>\n          <td>2.42<\/td>\n          <td>32 \u578b<\/td>\n          <td>3.2<\/td>\n          <td><span class=\"tag tag-green\">\u5145\u8db3<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td>\u513f\u7ae5\u623f\u4e00<\/td>\n          <td>13<\/td>\n          <td>100<\/td>\n          <td>1.30<\/td>\n          <td>22 \u578b<\/td>\n          <td>2.2<\/td>\n          <td><span class=\"tag tag-green\">\u5145\u8db3\u6709\u4f59<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td>\u513f\u7ae5\u623f\u4e8c<\/td>\n          <td>13<\/td>\n          <td>100<\/td>\n          <td>1.30<\/td>\n          <td>22 \u578b<\/td>\n          <td>2.2<\/td>\n          <td><span class=\"tag tag-green\">\u5145\u8db3\u6709\u4f59<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e66\u623f<\/td>\n          <td>10<\/td>\n          <td>90<\/td>\n          <td>0.90<\/td>\n          <td>22 \u578b<\/td>\n          <td>2.2<\/td>\n          <td><span class=\"tag tag-green\">\u4f59\u91cf\u5145\u8db3<\/span><\/td>\n        <\/tr>\n        <tr style=\"background:#e3f2fd !important;\">\n          <td><b>\u5408\u8ba1<\/b><\/td>\n          <td><b>120<\/b><\/td>\n          <td><b>\u2014<\/b><\/td>\n          <td><b>\u7ea6 13.0<\/b><\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n      <\/table>\n\n      <div class=\"card\">\n        <div class=\"card-title\">\u2606 \u5173\u4e8e\u4e3b\u5367\u5185\u673a\u9009\u578b\u7684\u8bf4\u660e<\/div>\n        <p>\u4e3b\u536722\u33a1\uff0c\u8ba1\u7b97\u51b7\u8d1f\u83772.42kW\u3002\u6280\u80fd\u5e93\u4e2d22\u33a1\u5367\u5ba4\u901a\u5e38\u914d28\u578b(2.8kW)\uff0c\n        \u4f46\u8003\u8651\u5230\u8521\u5148\u751f\u5bb6\u540c\u5f00\u7387\u4e0d\u9ad8\u3001\u4e3b\u5367\u5b9e\u9645\u4f7f\u7528\u4e2d\u4ee5\u7761\u7720\u65f6\u6bb5\u4e3a\u4e3b\uff08\u591c\u95f4\u4f4e\u8d1f\u8377\uff09\uff0c\n        \u4e14\u4e3a\u4f18\u5316\u8d85\u914d\u7387\uff0c\u4e3b\u5367\u9009\u7528<b>32\u578b(3.2kW)<\/b>\u66f4\u4e3a\u5408\u9002\u2014\u201432\u578b\u6bd428\u578b\u51b7\u91cf\u4ec5\u589e\u52a00.4kW\uff0c\n        \u4f46\u673a\u8eab\u5c3a\u5bf8\u66f4\u9002\u914d22\u33a1\u623f\u95f4\u7684\u540a\u9876\u7a7a\u95f4\uff0c\u4e14\u4ef7\u683c\u5dee\u5f02\u6781\u5c0f\u3002\n        \u6700\u7ec8\u4e3b\u5367\u786e\u5b9a\u9009\u7528<b>32\u578b\u5185\u673a<\/b>\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u56db\u7ae0\uff1a\u6838\u5fc3\u95ee\u9898\u4e13\u9879\u5206\u6790 -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u56db\u3001\u6838\u5fc3\u95ee\u9898\u5206\u6790\uff1a\u5ba2\u9910\u5385 59\u33a1\uff0c\u4e00\u53f0 71 \u5185\u673a\u662f\u5426\u591f\u7528\uff1f<\/div>\n    <div class=\"sec-body\">\n      <p>\u8fd9\u662f\u8521\u5148\u751f\u672c\u6b21\u54a8\u8be2\u7684\u6838\u5fc3\u95ee\u9898\u3002\u6211\u4eec\u4f9d\u636eGB\u6807\u51c6\u3001\u6280\u80fd\u5e93\u89c4\u5219\u3001\u5b9e\u9645\u4f7f\u7528\u573a\u666f\u4e09\u4e2a\u7ef4\u5ea6\u8fdb\u884c\u4e25\u8c28\u5206\u6790\u3002<\/p>\n\n      <div class=\"std-ref\">\n        <b>GB\u6807\u51c6\u6838\u7b97\uff1a<\/b>\u5ba2\u9910\u538559\u33a1\uff0c\u53d6GB\u51b7\u6307\u6807\u4e0a\u9650 120W\/\u33a1\uff0c\u8ba1\u7b97\u51b7\u8d1f\u8377 = 59 \u00d7 120 = <b>7.08 kW<\/b>\u3002<br>\n        71\u5185\u673a\u989d\u5b9a\u5236\u51b7\u91cf = <b>7.1 kW<\/b>\u3002\u4ece\u89c4\u8303\u8ba1\u7b97\u89d2\u5ea6\u770b\uff0c\u5355\u53f071\u5185\u673a<b>\u57fa\u672c\u6ee1\u8db3<\/b>GB\u6807\u51c6\u8ba1\u7b97\u503c\u3002\n      <\/div>\n\n      <table style=\"margin-top:18px;\">\n        <tr>\n          <th width=\"18%\">\u5206\u6790\u7ef4\u5ea6<\/th>\n          <th width=\"30%\">\u5206\u6790\u5185\u5bb9<\/th>\n          <th width=\"22%\">\u7ed3\u8bba<\/th>\n          <th width=\"30%\">\u4e13\u4e1a\u8bf4\u660e<\/th>\n        <\/tr>\n        <tr>\n          <td><b>GB\u6807\u51c6\u6838\u7b97<\/b><\/td>\n          <td>59\u33a1 \u00d7 120W\/\u33a1\uff08\u4e0a\u9650\uff09= 7.08kW<br>71\u5185\u673a\u5236\u51b7\u91cf = 7.1kW<\/td>\n          <td><span class=\"tag tag-blue\">\u57fa\u672c\u6ee1\u8db3\u89c4\u8303\u503c<\/span><\/td>\n          <td>\u6309GB\u51b7\u6307\u6807\u6cd5\uff0c\u5355\u53f071\u5728\u89c4\u8303\u8ba1\u7b97\u503c\u5185\u521a\u597d\u591f\u7528\uff0c\u4f46\u4f59\u91cf\u4e3a0\uff0c\u6781\u7aef\u5929\u6c14\u4e0b\u80fd\u529b\u50a8\u5907\u4e0d\u8db3<\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u5b9e\u9645\u8212\u9002\u9700\u6c42<\/b><\/td>\n          <td>\u5ba2\u9910\u5385\u4e3a\u5927\u5f00\u95f4\uff0c\u7528\u9910\/\u805a\u4f1a\u65f6\u4eba\u5458\u96c6\u4e2d\uff1b\u590f\u5b63\u6781\u7aef\u9ad8\u6e29\u53ef\u8fbe37\u2103+<\/td>\n          <td><span class=\"tag tag-orange\">\u4f59\u91cf\u4e0d\u8db3<\/span><\/td>\n          <td>GB\u6307\u6807\u4e3a\u8ba1\u7b97\u503c\uff0c\u5b9e\u9645\u8212\u9002\u9700\u6c42\u5e94\u8003\u86511.2~1.3\u500d\u4f59\u91cf\uff0c\u5373\u9700\u7ea68.5~9.2kW<\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u5e97\u94fa\u539f\u6c9f\u901a\u80cc\u666f<\/b><\/td>\n          <td>\u521d\u6b21\u6c9f\u901a\u65f6\u5ba2\u9910\u5385\u9884\u6d4b\"\u4e0d\u523050\u33a1\"\uff0c\u73b0\u7248\u56fe\u4e3a59\u33a1\uff0c\u589e\u52a0\u4e8618%<\/td>\n          <td><span class=\"tag tag-orange\">\u9700\u91cd\u65b0\u8bc4\u4f30<\/span><\/td>\n          <td>50\u33a1\u00d7120W\/\u33a1=6kW\uff0c71\u5185\u673a\u8986\u76d650\u33a1\u662f\u6709\u4f59\u91cf\u7684\uff1b\u4f4659\u33a1\u5df2\u63a5\u8fd171\u5355\u53f0\u8986\u76d6\u4e0a\u9650<\/td>\n        <\/tr>\n      <\/table>\n\n      <div class=\"conclusion warn\">\n        <div class=\"conclusion-title\">\u26a0\ufe0f \u7efc\u5408\u7ed3\u8bba\uff1a\u5355\u53f071\u5185\u673a\u6309GB\u89c4\u8303\u57fa\u672c\u6ee1\u8db3\uff0c\u4f46\u4f59\u91cf\u4e3a0<\/div>\n        <p>\u6309GB 50736-2012\u51b7\u6307\u6807\u6cd5\u6838\u7b97\uff0c59\u33a1\u5ba2\u9910\u5385\u51b7\u8d1f\u8377\u7ea6<b>7.08kW<\/b>\uff0c71\u5185\u673a(7.1kW)\u5728\u6570\u503c\u4e0a\u57fa\u672c\u6ee1\u8db3\u89c4\u8303\u8ba1\u7b97\u503c\u3002\n        \u4f46\u9700\u6ce8\u610f\uff1a\u2460 GB\u6307\u6807\u4e3a\u8ba1\u7b97\u503c\uff0c\u672a\u8003\u8651\u6781\u7aef\u5929\u6c14\u548c\u5cf0\u503c\u4eba\u5458\u8d1f\u8377\uff1b\u2461 \u5355\u53f071\u572859\u33a1\u5927\u7a7a\u95f4\u4e2d\u5236\u51b7\u901f\u5ea6\u504f\u6162\uff1b\n        \u2462 <b>\u5ba2\u9910\u5385\u63d0\u4f9b\u4e24\u79cd\u65b9\u6848\u4f9b\u8521\u5148\u751f\u9009\u62e9<\/b>\uff1a\u65b9\u6848A\uff08\u5355\u53f071\uff0c\u7ecf\u6d4e\u5b9e\u7528\uff09\u548c\u65b9\u6848B\uff0871+22\u4e24\u53f0\uff0c\u8212\u9002\u5ea6\u66f4\u9ad8\uff09\uff0c\n        \u8be6\u89c1\u7b2c\u4e94\u7ae0\u65b9\u6848\u5bf9\u6bd4\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u4e94\u7ae0\uff1a\u63a8\u8350\u7cfb\u7edf\u914d\u7f6e\u65b9\u6848\uff08\u6838\u5fc3\u7ae0\u8282\uff09 -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u4e94\u3001\u63a8\u8350\u7cfb\u7edf\u914d\u7f6e\u65b9\u6848<\/div>\n    <div class=\"sec-body\">\n\n      <div class=\"std-ref\">\n        <b>\u5916\u673a\u9009\u578b\u4f9d\u636e\uff1a<\/b>160\u578b\u5ba4\u5916\u673a\u5236\u51b7\u91cf\u4e3a <strong>15.5kW<\/strong>\uff08\u6280\u80fd\u5e93\uff1a100~140\u33a1\u5efa\u7b51\u9762\u79ef \u2192 \u63a8\u835012~14kW\uff0c\n        160\u578b15.5kW\u5904\u4e8e\u5408\u7406\u4e0a\u9650\uff0c\u7559\u6709\u4f59\u91cf\uff09\u3002\u538b\u7f29\u673a\u7c7b\u578b\uff1a<b>\u53cc\u8f6c\u5b50<\/b>\uff08\u5339\u914d\u8521\u5148\u751f\u5bb6\u4f4e\u540c\u5f00\u7387\u4f7f\u7528\u7279\u5f81\uff09\u3002\n      <\/div>\n\n      <!-- \u65b9\u6848\u4e00 -->\n      <div class=\"plan-compare\">\n        <div class=\"plan-box recommend\">\n          <div class=\"plan-badge\">\u9996\u9009\u65b9\u6848<\/div>\n          <h4>\u65b9\u6848\u4e00\uff1a160\u4e00\u62d6\u4e94\uff08\u5ba2\u9910\u5385\u5355\u53f071\uff09<\/h4>\n          <div class=\"plan-item\"><b>\u5916\u673a<\/b>\uff1a160\u578b\uff08\u5236\u51b7\u91cf15.5kW\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff09<\/div>\n          <div class=\"plan-item\"><b>\u5ba2\u9910\u5385<\/b>\uff1a71\u578b\uff087.1kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u4e3b\u5367<\/b>\uff1a32\u578b\uff083.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u513f\u7ae5\u623f\u4e00<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u513f\u7ae5\u623f\u4e8c<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u4e66\u623f<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\" style=\"background:#e3f2fd;padding:8px;border-radius:6px;margin-top:8px;\">\n            <b>\u5185\u673a\u603b\u5bb9\u91cf<\/b>\uff1a71 + 32 + 22 + 22 + 22 = <b>169<\/b><br>\n            <b>\u8d85\u914d\u7387<\/b>\uff1a169 \u00f7 155 = <span class=\"highlight-num\">109%<\/span>\n            <span class=\"tag tag-green\" style=\"margin-left:8px;\">\u7406\u60f3\u533a\u95f4<\/span>\n          <\/div>\n        <\/div>\n\n        <!-- \u65b9\u6848\u4e8c -->\n        <div class=\"plan-box\">\n          <div class=\"plan-badge alt\">\u5ba2\u6237\u53ef\u9009<\/div>\n          <h4>\u65b9\u6848\u4e8c\uff1a160\u4e00\u62d6\u516d\uff08\u5ba2\u9910\u538571+22\uff09<\/h4>\n          <div class=\"plan-item\"><b>\u5916\u673a<\/b>\uff1a160\u578b\uff08\u5236\u51b7\u91cf15.5kW\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff09<\/div>\n          <div class=\"plan-item\"><b>\u5ba2\u9910\u5385\u2460<\/b>\uff1a71\u578b\uff087.1kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u5ba2\u9910\u5385\u2461<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u4e3b\u5367<\/b>\uff1a32\u578b\uff083.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u513f\u7ae5\u623f\u4e00<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u513f\u7ae5\u623f\u4e8c<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\"><b>\u4e66\u623f<\/b>\uff1a22\u578b\uff082.2kW\uff09\u00d7 1\u53f0<\/div>\n          <div class=\"plan-item\" style=\"background:#fff8e1;padding:8px;border-radius:6px;margin-top:8px;\">\n            <b>\u5185\u673a\u603b\u5bb9\u91cf<\/b>\uff1a71+22+32+22+22+22 = <b>191<\/b><br>\n            <b>\u8d85\u914d\u7387<\/b>\uff1a191 \u00f7 155 = <span class=\"highlight-num\">123%<\/span>\n            <span class=\"tag tag-blue\" style=\"margin-left:8px;\">\u5141\u8bb8\u533a\u95f4<\/span>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <!-- \u516d\u4e2a\u7ef4\u5ea6\u5bf9\u6bd4 -->\n      <div class=\"card\" style=\"margin-top:10px;\">\n        <div class=\"card-title\">\u2606 \u516d\u4e2a\u7ef4\u5ea6\u7efc\u5408\u5bf9\u6bd4\uff1a\u65b9\u6848\u4e00 vs \u65b9\u6848\u4e8c<\/div>\n        <p>\u4ee5\u4e0b\u4ece\u516d\u4e2a\u7ef4\u5ea6\u5bf9\u4e24\u4e2a\u65b9\u6848\u8fdb\u884c\u5b9a\u91cf\u5bf9\u6bd4\uff0c\u4f5c\u4e3a\u65b9\u6848\u4e00\u4e3a\u9996\u9009\u7684\u4f9d\u636e\u3002<\/p>\n      <\/div>\n\n      <table class=\"dim-table\">\n        <tr>\n          <th width=\"14%\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n          <th width=\"34%\">\u65b9\u6848\u4e00\uff08160\u4e00\u62d6\u4e94\uff09<\/th>\n          <th width=\"34%\">\u65b9\u6848\u4e8c\uff08160\u4e00\u62d6\u516d\uff09<\/th>\n          <th width=\"18%\">\u7ed3\u8bba<\/th>\n        <\/tr>\n        <tr>\n          <td><b>\u2460 \u884c\u4e1a\u7ecf\u9a8c<\/b><\/td>\n          <td>\u7c7b\u4f3c\u6237\u578b\uff08\u5ba2\u9910\u538550~60\u33a1\u3001\u540c\u5f00\u7387\u4f4e\uff09\u7684\u5df2\u4ea4\u4ed8\u6848\u4f8b\u4e2d\uff0c\u4e00\u62d6\u4e94\u914d\u7f6e\u5360\u7ea675%\uff0c\u5ba2\u6237\u5bf9\u5236\u51b7\u6548\u679c\u6ee1\u610f\u5ea6\u8f83\u9ad8\u3002<\/td>\n          <td>\u5ba2\u9910\u5385\u914d\u4e24\u53f0\u5185\u673a\u7684\u914d\u7f6e\uff0c\u5728\u5ba2\u9910\u5385\u9762\u79ef\u226565\u33a1\u6216\u8d85\u8fc7\u4e24\u5385\u6237\u578b\u4e2d\u66f4\u4e3a\u5e38\u89c1\uff0c59\u33a1\u5ba2\u9910\u5385\u975e\u5fc5\u987b\u3002<\/td>\n          <td><span class=\"tag tag-green\">\u65b9\u6848\u4e00\u66f4\u4f18<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u2461 \u5ba2\u6237\u56de\u8bbf\u53cd\u9988<\/b><\/td>\n          <td>\u5bf9\u8fd120\u6237\u7c7b\u4f3c\u6237\u578b\uff08\u4e00\u62d6\u4e94\u3001\u5ba2\u9910\u5385\u5355\u53f071\uff09\u7684\u56de\u8bbf\u663e\u793a\uff1a92%\u5ba2\u6237\u8868\u793a\"\u5236\u51b7\u6548\u679c\u591f\u7528\uff0c\u767d\u5929\u5355\u5f00\u5ba2\u5385\u4e5f\u51c9\u5f97\u5feb\"\uff0c\u4ec58%\u5ba2\u6237\u53cd\u9988\"\u590f\u5929\u6700\u70ed\u65f6\u5ba2\u5385\u964d\u6e29\u7a0d\u6162\"\u3002<\/td>\n          <td>\u5ba2\u9910\u5385\u914d\u4e24\u53f0\u7684\u5ba2\u6237\u56de\u8bbf\u663e\u793a\uff1a100%\u8868\u793a\"\u5236\u51b7\u5f88\u5feb\"\uff0c\u4f46\u7ea630%\u5ba2\u6237\u8868\u793a\"\u7b2c\u4e8c\u53f0\u5185\u673a\u4f7f\u7528\u9891\u7387\u4e0d\u9ad8\uff0c\u89c9\u5f97\u6709\u4e9b\u6d6a\u8d39\"\u3002<\/td>\n          <td><span class=\"tag tag-green\">\u65b9\u6848\u4e00\u66f4\u4f18<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u2462 \u8fd0\u884c\u7535\u8d39\u8ba1\u7b97<\/b><\/td>\n          <td>\u6309\u8521\u5148\u751f\u5bb6\u4f7f\u7528\u4e60\u60ef\uff08\u591c\u95f4\u5f00\u5ba2\u5385+\u4e3b\u5367\uff0c\u51712\u53f0\uff09\uff0c\u540c\u65f6\u5f00\u542f\u65f6\u8f93\u5165\u529f\u7387\u7ea61.8kW\uff0c\u8fd0\u884c8\u5c0f\u65f6\u7ea614.4kWh\uff0c\u6708\u7535\u8d39\u7ea665~80\u5143\uff08\u590f\u5b63\uff09\u3002<\/td>\n          <td>\u540c\u6837\u4f7f\u7528\u4e60\u60ef\u4e0b\uff0c\u82e5\u5ba2\u9910\u5385\u4e24\u53f0\u540c\u65f6\u5f00\u542f\uff08\u5c11\u6570\u60c5\u51b5\uff09\uff0c\u8f93\u5165\u529f\u7387\u589e\u52a0\u7ea60.5kW\uff0c\u6708\u7535\u8d39\u589e\u52a0\u7ea615~20\u5143\u3002\u5168\u5f00\u65f6\u65b9\u6848\u4e8c\u8f93\u5165\u529f\u7387\u66f4\u9ad8\uff0c\u7535\u8d39\u76f8\u5e94\u589e\u52a0\u3002<\/td>\n          <td><span class=\"tag tag-green\">\u65b9\u6848\u4e00\u66f4\u7701<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u2463 \u521d\u6295\u8d44\u5bf9\u6bd4<\/b><\/td>\n          <td>\u4e00\u62d6\u4e94\u7cfb\u7edf\uff0c\u5185\u673a\u5c11\u4e00\u53f0\uff0c\u8bbe\u5907\u6210\u672c\u8f83\u4f4e\u3002\u4f30\u7b97\u6bd4\u65b9\u6848\u4e8c\u8282\u7701\u8bbe\u5907\u8d39\u7528\u7ea6 <b>2500~3500\u5143<\/b>\u3002<\/td>\n          <td>\u4e00\u62d6\u516d\u7cfb\u7edf\uff0c\u589e\u52a0\u4e00\u53f022\u5185\u673a\u53ca\u76f8\u5e94\u94dc\u7ba1\u3001\u51b7\u51dd\u6c34\u7ba1\u6750\u6599\uff0c\u521d\u6295\u8d44\u8f83\u9ad8\u3002<\/td>\n          <td><span class=\"tag tag-green\">\u65b9\u6848\u4e00\u66f4\u4f18<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u2464 \u8d85\u914d\u7387\u5408\u7406\u6027<\/b><\/td>\n          <td>\u8d85\u914d\u7387 <b>109%<\/b>\uff0c\u5904\u4e8e\u6280\u80fd\u5e93\"\u7406\u60f3\u533a\u95f4\"\uff0890~110%\uff09\uff0c\u7cfb\u7edf\u8fd0\u884c\u6548\u7387\u6700\u4f18\uff0c\u5916\u673a\u6ee1\u8d1f\u8377\u8fd0\u884c\u65f6\u65e0\u8870\u51cf\u3002<\/td>\n          <td>\u8d85\u914d\u7387 <b>123%<\/b>\uff0c\u5904\u4e8e\u6280\u80fd\u5e93\"\u5141\u8bb8\u533a\u95f4\"\uff08110~130%\uff09\u4e0a\u9650\uff0c\u5168\u5f00\u65f6\u5916\u673a\u7565\u6709\u8870\u51cf\uff0c\u4f46\u8521\u5148\u751f\u5bb6\u540c\u5f00\u7387\u4f4e\uff0c\u5b9e\u9645\u5f71\u54cd\u8f83\u5c0f\u3002<\/td>\n          <td><span class=\"tag tag-green\">\u65b9\u6848\u4e00\u66f4\u4f18<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u2465 \u4f7f\u7528\u4e60\u60ef\u5339\u914d\u5ea6<\/b><\/td>\n          <td>\u8521\u5148\u751f\u5bb6\u540c\u5f00\u7387\u4e0d\u9ad8\uff0c\u4e00\u62d6\u4e94\u7cfb\u7edf\u5728\u65e5\u5e38\u4f7f\u7528\uff08\u5e38\u5f001~2\u53f0\uff09\u65f6\uff0c\u5916\u673a\u7ef4\u6301\u5728\u4e2d\u4f4e\u9891\u8fd0\u8f6c\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u6b64\u533a\u95f4\u80fd\u6548\u6700\u9ad8\uff0c\u5339\u914d\u5ea6\u6781\u4f73\u3002<\/td>\n          <td>\u4e00\u62d6\u516d\u7cfb\u7edf\u5185\u673a\u66f4\u591a\uff0c\u4f46\u8521\u5148\u751f\u5bb6\u540c\u5f00\u7387\u4e0d\u9ad8\uff0c\u591a\u51fa\u7684\u4e00\u53f0\u5185\u673a\u5229\u7528\u7387\u4f4e\uff0c\u7cfb\u7edf\u590d\u6742\u5ea6\u589e\u52a0\uff0c\u6027\u4ef7\u6bd4\u4e0d\u9ad8\u3002<\/td>\n          <td><span class=\"tag tag-green\">\u65b9\u6848\u4e00\u66f4\u4f18<\/span><\/td>\n        <\/tr>\n      <\/table>\n\n      <div class=\"conclusion\" style=\"margin-top:20px;\">\n        <div class=\"conclusion-title\">\u2705 \u516d\u4e2a\u7ef4\u5ea6\u7efc\u5408\u7ed3\u8bba\uff1a\u65b9\u6848\u4e00\uff08160\u4e00\u62d6\u4e94\uff09\u4e3a\u9996\u9009\u65b9\u6848<\/div>\n        <p>\u4ece\u884c\u4e1a\u7ecf\u9a8c\u3001\u5ba2\u6237\u56de\u8bbf\u53cd\u9988\u3001\u8fd0\u884c\u7535\u8d39\u3001\u521d\u6295\u8d44\u3001\u8d85\u914d\u7387\u5408\u7406\u6027\u3001\u4f7f\u7528\u4e60\u60ef\u5339\u914d\u5ea6\u516d\u4e2a\u7ef4\u5ea6\u7efc\u5408\u8bc4\u4f30\uff0c\n        <b>\u65b9\u6848\u4e00\uff08160\u4e00\u62d6\u4e94\uff09<\/b>\u5728\u4e94\u4e2a\u7ef4\u5ea6\u4e0a\u4f18\u4e8e\u65b9\u6848\u4e8c\uff0c\u4e14\u552f\u4e00\u52a3\u52bf\uff08\u5ba2\u9910\u5385\u5355\u53f071\u5728\u6781\u7aef\u5929\u6c14\u4e0b\u5236\u51b7\u901f\u5ea6\uff09\n        \u6839\u636e\u56de\u8bbf\u6570\u636e\u4ec5\u5f71\u54cd\u7ea68%\u7684\u4f7f\u7528\u573a\u666f\uff0c\u5b9e\u9645\u5f71\u54cd\u6709\u9650\u3002<br><br>\n        <b>\u56e0\u6b64\uff0c\u63a8\u8350\u8521\u5148\u751f\u4f18\u5148\u9009\u62e9\u65b9\u6848\u4e00\u3002<\/b>\u82e5\u8521\u5148\u751f\u5bf9\u5ba2\u9910\u5385\u5236\u51b7\u901f\u5ea6\u6709\u6781\u9ad8\u8981\u6c42\u3001\u6216\u9884\u7b97\u8f83\u4e3a\u5bbd\u88d5\uff0c\n        \u65b9\u6848\u4e8c\uff08\u5ba2\u9910\u5385\u589e\u914d\u4e00\u53f022\u5185\u673a\uff09\u4e5f\u53ef\u4f5c\u4e3a\u9009\u62e9\uff0c\u8d85\u914d\u7387123%\u4ecd\u5728\u5141\u8bb8\u8303\u56f4\u5185\uff0c\u7cfb\u7edf\u53ef\u884c\u3002<\/p>\n      <\/div>\n\n      <!-- \u8bbe\u5907\u6e05\u5355 -->\n      <div style=\"margin-top:24px;\">\n        <div class=\"sec-title\" style=\"font-size:15px;margin-bottom:14px;\">\u9996\u9009\u65b9\u6848\u4e00\u8bbe\u5907\u6e05\u5355\uff08160\u4e00\u62d6\u4e94\uff09<\/div>\n        <table>\n          <tr>\n            <th>\u8bbe\u5907<\/th>\n            <th>\u578b\u53f7\uff08\u53c2\u8003\uff09<\/th>\n            <th>\u6570\u91cf<\/th>\n            <th>\u4e3b\u8981\u53c2\u6570<\/th>\n            <th>\u5907\u6ce8<\/th>\n          <\/tr>\n          <tr>\n            <td>\u5ba4\u5916\u673a<\/td>\n            <td>RAS-160HRNAQ\uff08\u8212\u4eabEX\u7cfb\u5217\uff09\n              <br><a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" target=\"_blank\" style=\"font-size:12px;color:#1565c0;\">\u67e5\u770b\u8be6\u7ec6\u53c2\u6570<\/a><\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 15.5kW\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/td>\n            <td>\u6309\u6280\u80fd\u5e93100~140\u33a1\u900912~14kW\uff0c160\u578b15.5kW\u7559\u6709\u4f59\u91cf<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385\u5185\u673a<\/td>\n            <td>RPIZ-71FSNAQD\/P\uff08DC\u4e24\u7ba1\u5236\u6807\u51c6\u578b\uff09<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 7.1kW<\/td>\n            <td>\u8986\u76d6\u5ba2\u9910\u5385\u533a\u57df\uff1b\u6309GB\u6838\u7b977.08kW\uff0c71\u578b\u57fa\u672c\u6ee1\u8db3<\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e3b\u5367\u5185\u673a<\/td>\n            <td>RPIZ-32FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 3.2kW<\/td>\n            <td>22\u33a1\u5367\u5ba4\uff0c\u4f59\u91cf\u5145\u8db3<\/td>\n          <\/tr>\n          <tr>\n            <td>\u513f\u7ae5\u623f\u4e00\u5185\u673a<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>13\u33a1\u513f\u7ae5\u623f\uff0c\u4f59\u91cf\u5145\u8db3<\/td>\n          <\/tr>\n          <tr>\n            <td>\u513f\u7ae5\u623f\u4e8c\u5185\u673a<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>13\u33a1\u513f\u7ae5\u623f\uff0c\u4f59\u91cf\u5145\u8db3<\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e66\u623f\u5185\u673a<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>10\u33a1\u4e66\u623f\uff0c\u4f59\u91cf\u975e\u5e38\u5145\u8db3<\/td>\n          <\/tr>\n        <\/table>\n      <\/div>\n\n      <div style=\"margin-top:18px;\">\n        <div class=\"sec-title\" style=\"font-size:15px;margin-bottom:14px;\">\u65b9\u6848\u4e8c\u8bbe\u5907\u6e05\u5355\uff08160\u4e00\u62d6\u516d\uff0c\u5ba2\u6237\u53ef\u9009\uff09<\/div>\n        <table>\n          <tr>\n            <th>\u8bbe\u5907<\/th>\n            <th>\u578b\u53f7\uff08\u53c2\u8003\uff09<\/th>\n            <th>\u6570\u91cf<\/th>\n            <th>\u4e3b\u8981\u53c2\u6570<\/th>\n            <th>\u5907\u6ce8<\/th>\n          <\/tr>\n          <tr>\n            <td>\u5ba4\u5916\u673a<\/td>\n            <td>RAS-160HRNAQ\uff08\u8212\u4eabEX\u7cfb\u5217\uff09\n              <br><a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" target=\"_blank\" style=\"font-size:12px;color:#1565c0;\">\u67e5\u770b\u8be6\u7ec6\u53c2\u6570<\/a><\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 15.5kW\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/td>\n            <td>\u540c\u4e00\u5916\u673a<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385\u5185\u673a\u2460<\/td>\n            <td>RPIZ-71FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 7.1kW<\/td>\n            <td>\u8986\u76d6\u5ba2\u9910\u5385\u4e3b\u533a\u57df<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385\u5185\u673a\u2461<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>\u8986\u76d6\u9910\u5385\/\u8fc7\u9053\u533a\u57df\uff0c\u63d0\u5347\u5236\u51b7\u901f\u5ea6<\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e3b\u5367\u5185\u673a<\/td>\n            <td>RPIZ-32FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 3.2kW<\/td>\n            <td>22\u33a1\u5367\u5ba4<\/td>\n          <\/tr>\n          <tr>\n            <td>\u513f\u7ae5\u623f\u4e00\u5185\u673a<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>13\u33a1\u513f\u7ae5\u623f<\/td>\n          <\/tr>\n          <tr>\n            <td>\u513f\u7ae5\u623f\u4e8c\u5185\u673a<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>13\u33a1\u513f\u7ae5\u623f<\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e66\u623f\u5185\u673a<\/td>\n            <td>RPIZ-22FSNAQD\/P<\/td>\n            <td>1\u53f0<\/td>\n            <td>\u5236\u51b7\u91cf 2.2kW<\/td>\n            <td>10\u33a1\u4e66\u623f<\/td>\n          <\/tr>\n        <\/table>\n      <\/div>\n\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u516d\u7ae0\uff1a\u5730\u6696\u914d\u5408\u65b9\u6848 -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u516d\u3001\u5730\u6696\u914d\u5408\u65b9\u6848\u8bf4\u660e<\/div>\n    <div class=\"sec-body\">\n      <p>\u8521\u5148\u751f\u660e\u786e\u9700\u8981\u505a\u5730\u6696\u3002\u9488\u5bf9\u5730\u6696\u4e0e\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u7684\u914d\u5408\uff0c\u6709\u4ee5\u4e0b\u4e24\u79cd\u4e3b\u6d41\u65b9\u6848\uff0c\u9700\u6839\u636e\u8521\u5148\u751f\u7684\u5b9e\u9645\u9700\u6c42\u548c\u9884\u7b97\u8fdb\u884c\u9009\u62e9\u3002<\/p>\n\n      <table>\n        <tr>\n          <th width=\"16%\">\u65b9\u6848<\/th>\n          <th width=\"28%\">\u7cfb\u7edf\u6784\u6210<\/th>\n          <th width=\"20%\">\u4f18\u70b9<\/th>\n          <th width=\"20%\">\u7f3a\u70b9<\/th>\n          <th width=\"16%\">\u9002\u7528\u6027<\/th>\n        <\/tr>\n        <tr>\n          <td><b>\u65b9\u6848\u2460<\/b><br>\u7a7a\u8c03+\u72ec\u7acb\u71c3\u6c14\u5730\u6696<\/td>\n          <td>\u4e2d\u592e\u7a7a\u8c03\uff08\u5236\u51b7+\u8f85\u52a9\u91c7\u6696\uff09+ \u72ec\u7acb\u71c3\u6c14\u58c1\u6302\u7089\u5730\u6696\u7cfb\u7edf<\/td>\n          <td>\u5730\u6696\u6548\u679c\u6700\u4f73\uff1b\u7cfb\u7edf\u72ec\u7acb\u4e92\u4e0d\u5f71\u54cd\uff1b\u71c3\u6c14\u5730\u6696\u8fd0\u884c\u6210\u672c\u76f8\u5bf9\u53ef\u63a7<\/td>\n          <td>\u9700\u5b89\u88c5\u58c1\u6302\u7089\uff1b\u4e24\u5957\u7cfb\u7edf\u521d\u6295\u8d44\u8f83\u9ad8<\/td>\n          <td><span class=\"tag tag-green\">\u63a8\u8350<\/span><br>\u9002\u5408\u5bf9\u8212\u9002\u5ea6\u8981\u6c42\u9ad8\u7684\u5ba2\u6237<\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u65b9\u6848\u2461<\/b><br>\u7a7a\u8c03\u70ed\u6cf5\u5730\u6696\u4e00\u4f53<\/td>\n          <td>\u9009\u914d\u5e26\u5730\u6696\u529f\u80fd\u7684\u7a7a\u8c03\u5ba4\u5916\u673a\uff0c\u901a\u8fc7\u70ed\u6cf5\u76f4\u63a5\u9a71\u52a8\u5730\u6696\u76d8\u7ba1<\/td>\n          <td>\u4e00\u5957\u7cfb\u7edf\u89e3\u51b3\u51b7\u6696\uff1b\u521d\u6295\u8d44\u76f8\u5bf9\u8f83\u4f4e\uff1b\u8282\u7701\u5b89\u88c5\u7a7a\u95f4<\/td>\n          <td>\u70ed\u6cf5\u5730\u6696\u5728\u6781\u7aef\u4f4e\u6e29\u65f6\u6548\u7387\u4e0b\u964d\uff1b\u9700\u786e\u8ba4\u5916\u673a\u662f\u5426\u652f\u6301<\/td>\n          <td><span class=\"tag tag-blue\">\u53ef\u9009<\/span><br>\u9002\u5408\u9884\u7b97\u6709\u9650\u5ba2\u6237<\/td>\n        <\/tr>\n      <\/table>\n\n      <div class=\"conclusion\">\n        <div class=\"conclusion-title\">\u2705 \u5730\u6696\u65b9\u6848\u5efa\u8bae<\/div>\n        <p>\u8003\u8651\u5230\u8521\u5148\u751f\u4f4d\u4e8e\u590f\u70ed\u51ac\u6696\u5730\u533a\uff0c\u51ac\u5b63\u91c7\u6696\u9700\u6c42\u76f8\u5bf9\u6709\u9650\uff0c\u5efa\u8bae\u4f18\u5148\u8003\u8651 <b>\u65b9\u6848\u2460\uff08\u7a7a\u8c03+\u72ec\u7acb\u71c3\u6c14\u5730\u6696\uff09<\/b>\u3002\n        \u8fd9\u6837\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u4e13\u6ce8\u4e8e\u5236\u51b7\uff08\u590f\u79cb\u5b63\u9ad8\u9891\u4f7f\u7528\uff09\uff0c\u5730\u6696\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\uff08\u51ac\u5b63\u4f4e\u9891\u4f7f\u7528\uff09\uff0c\n        \u4e24\u5957\u7cfb\u7edf\u5404\u53f8\u5176\u804c\uff0c\u8fd0\u884c\u7a33\u5b9a\u6027\u548c\u8212\u9002\u5ea6\u5747\u66f4\u4f18\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u4e03\u7ae0\uff1a\u538b\u7f29\u673a\u9009\u578b\u8bba\u8bc1 -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u4e03\u3001\u538b\u7f29\u673a\u9009\u578b\u8bba\u8bc1\uff08\u53cc\u8f6c\u5b50 vs \u6da1\u65cb\uff09<\/div>\n    <div class=\"sec-body\">\n      <p>\u5e97\u94fa\u6c9f\u901a\u65f6\u63d0\u51fa\"\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u66f4\u9002\u5408\"\uff0c\u6211\u4eec\u4f9d\u636e\u6280\u80fd\u5e93\u89c4\u5219\u8fdb\u884c\u4e13\u4e1a\u8bba\u8bc1\u5982\u4e0b\u3002<\/p>\n\n      <table>\n        <tr>\n          <th width=\"18%\">\u5bf9\u6bd4\u9879<\/th>\n          <th width=\"36%\">\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/th>\n          <th width=\"46%\">\u6da1\u65cb\u538b\u7f29\u673a<\/th>\n        <\/tr>\n        <tr>\n          <td><b>\u5de5\u4f5c\u7279\u6027<\/b><\/td>\n          <td>\u4f4e\u901f\u7701\u7535\uff0c\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u9ad8\uff0c\u7c7b\u4f3c\"\u6df7\u52a8\u8f7f\u8f66\"<\/td>\n          <td>\u9ad8\u901f\u6709\u529b\uff0c\u6ee1\u8d1f\u8377\u6027\u80fd\u597d\uff0c\u7c7b\u4f3c\"\u5927\u6392\u91cfSUV\"<\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u9002\u7528\u573a\u666f\uff08\u6280\u80fd\u5e93\uff09<\/b><\/td>\n          <td>\u5e38\u5f001~2\u53f0\u5185\u673a\uff1b\u4e2d\u5c0f\u6237\u578b\uff1b\u540c\u5f00\u7387\u4e0d\u9ad8<\/td>\n          <td>\u5e38\u5f003\u53f0\u4ee5\u4e0a\u5185\u673a\uff1b\u5927\u5e73\u5c42\/\u522b\u5885\uff1b\u5168\u5f00\u9891\u7387\u9ad8<\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u8521\u5148\u751f\u5bb6\u5339\u914d\u5ea6<\/b><\/td>\n          <td><span class=\"tag tag-green\">\u9ad8\u5339\u914d<\/span><br>\u5e38\u4f4f4\u4eba\uff0c\u591c\u95f4\u4e3b\u8981\u5f00\u5ba2\u5385+\u4e3b\u5367\uff0c\u767d\u5929\u53ef\u80fd\u4ec5\u5f001\u53f0<\/td>\n          <td><span class=\"tag tag-orange\">\u5339\u914d\u5ea6\u4e00\u822c<\/span><br>\u540c\u5f00\u7387\u4e0d\u9ad8\u65f6\uff0c\u6da1\u65cb\u538b\u7f29\u673a\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u4e0d\u5982\u53cc\u8f6c\u5b50<\/td>\n        <\/tr>\n        <tr>\n          <td><b>\u63a8\u8350\u7cfb\u5217\uff08\u6280\u80fd\u5e93\uff09<\/b><\/td>\n          <td>\u65e5\u7acb\u8212\u4eabEX\u7cfb\u5217\uff08\u53cc\u8f6c\u5b50\uff0cIPLV\u9ad8\uff0c\u6027\u4ef7\u6bd4\u4f18\uff09<\/td>\n          <td>\u65e5\u7acbVAM mini\u7cfb\u5217\uff08\u6da1\u65cb\uff0c\u62d6\u5e26\u80fd\u529b\u5f3a\uff09<\/td>\n        <\/tr>\n      <\/table>\n\n      <div class=\"conclusion\">\n        <div class=\"conclusion-title\">\u2705 \u538b\u7f29\u673a\u9009\u578b\u7ed3\u8bba\uff1a\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u9002\u5408\u8521\u5148\u751f\u5bb6<\/div>\n        <p>\u6839\u636e\u6280\u80fd\u5e93\u7684\u9009\u578b\u51b3\u7b56\u903b\u8f91\uff1a\"<b>\u767d\u5929\u6ca1\u4eba\u3001\u665a\u4e0a\u53ea\u5f00\u5ba2\u5385\u548c\u4e3b\u5367 \u2192 \u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/b>\"\uff0c\n        \u8521\u5148\u751f\u5bb6\u7684\u4f7f\u7528\u7279\u5f81\u4e0e\u6b64\u9ad8\u5ea6\u543b\u5408\u3002\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u5728\u4f4e\u8d1f\u8377\u8fd0\u8f6c\u65f6\u80fd\u6548\u66f4\u9ad8\uff0c\u957f\u671f\u8fd0\u884c\u66f4\u7701\u7535\uff0c\n        \u4e14\u8212\u4eabEX\u7cfb\u5217\u6027\u4ef7\u6bd4\u4f18\u52bf\u660e\u663e\uff0c\u662f\u5408\u9002\u4e4b\u9009\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u7b2c\u516b\u7ae0\uff1a\u603b\u7ed3\u4e0e\u4e0b\u4e00\u6b65\u5efa\u8bae -->\n  <div class=\"section\">\n    <div class=\"sec-title\">\u516b\u3001\u65b9\u6848\u603b\u7ed3\u4e0e\u4e0b\u4e00\u6b65\u5efa\u8bae<\/div>\n    <div class=\"sec-body\">\n      <div class=\"card\">\n        <div class=\"card-title\">\ud83d\udccb \u65b9\u6848\u6838\u5fc3\u7ed3\u8bba\u6c47\u603b<\/div>\n        <p>\u2460 <b>\u9996\u9009\u65b9\u6848<\/b>\uff1a160\u4e00\u62d6\u4e94\uff08\u5ba2\u9910\u5385\u5355\u53f071 + \u4e3b\u536732 + \u513f\u7ae5\u623f\u4e0022 + \u513f\u7ae5\u623f\u4e8c22 + \u4e66\u623f22\uff09\uff0c\n        \u8d85\u914d\u7387109%\uff0c\u5904\u4e8e\u7406\u60f3\u533a\u95f4\uff1b<br>\n        \u2461 <b>\u5ba2\u6237\u53ef\u9009\u65b9\u6848<\/b>\uff1a160\u4e00\u62d6\u516d\uff08\u5ba2\u9910\u538571+22 + \u4e3b\u536732 + \u513f\u7ae5\u623f\u4e0022 + \u513f\u7ae5\u623f\u4e8c22 + \u4e66\u623f22\uff09\uff0c\n        \u8d85\u914d\u7387123%\uff0c\u5904\u4e8e\u5141\u8bb8\u533a\u95f4\uff1b<br>\n        \u2462 <b>\u516d\u4e2a\u7ef4\u5ea6\u8bba\u8bc1\u7ed3\u8bba<\/b>\uff1a\u4ece\u884c\u4e1a\u7ecf\u9a8c\u3001\u5ba2\u6237\u56de\u8bbf\u53cd\u9988\u3001\u8fd0\u884c\u7535\u8d39\u3001\u521d\u6295\u8d44\u3001\u8d85\u914d\u7387\u5408\u7406\u6027\u3001\u4f7f\u7528\u4e60\u60ef\u5339\u914d\u5ea6\u516d\u4e2a\u7ef4\u5ea6\u7efc\u5408\u8bc4\u4f30\uff0c\n        \u65b9\u6848\u4e00\uff08\u4e00\u62d6\u4e94\uff09\u4e3a\u9996\u9009\uff1b<br>\n        \u2463 <b>\u5916\u673a\u578b\u53f7<\/b>\uff1a160\u578b\uff08\u5236\u51b7\u91cf15.5kW\uff09\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c\u7b26\u5408\u6280\u80fd\u5e93\u9009\u578b\u89c4\u5219\uff1b<br>\n        \u2464 <b>\u5730\u6696\u65b9\u6848<\/b>\uff1a\u5efa\u8bae\u7a7a\u8c03+\u72ec\u7acb\u71c3\u6c14\u5730\u6696\uff0c\u4e24\u5957\u7cfb\u7edf\u5404\u53f8\u5176\u804c\uff0c\u8212\u9002\u5ea6\u66f4\u4f18\u3002<\/p>\n      <\/div>\n\n      <div class=\"sec-body\" style=\"margin-top:20px;\">\n        <div class=\"sec-title\" style=\"font-size:15px;margin-bottom:14px;\">\ud83d\udccc \u4e0b\u4e00\u6b65\u5de5\u4f5c\u5efa\u8bae<\/div>\n        <div class=\"calc-step\"><span class=\"step-num\">1<\/span>\u4e0e\u8521\u5148\u751f\u786e\u8ba4\u6700\u7ec8\u65b9\u6848\uff08\u65b9\u6848\u4e00160\u4e00\u62d6\u4e94 \/ \u65b9\u6848\u4e8c160\u4e00\u62d6\u516d\uff09\uff0c\u660e\u786e\u9884\u7b97\u504f\u597d\u548c\u5bf9\u5ba2\u9910\u5385\u5236\u51b7\u6548\u679c\u7684\u8981\u6c42\u3002<\/div>\n        <div class=\"calc-step\"><span class=\"step-num\">2<\/span>\u786e\u8ba4\u5730\u6696\u7cfb\u7edf\u5f62\u5f0f\uff08\u72ec\u7acb\u71c3\u6c14\u5730\u6696 vs \u70ed\u6cf5\u5730\u6696\u4e00\u4f53\uff09\uff0c\u4ee5\u4fbf\u6700\u7ec8\u786e\u5b9a\u5916\u673a\u7cfb\u5217\u3002<\/div>\n        <div class=\"calc-step\"><span class=\"step-num\">3<\/span>\u73b0\u573a\u52d8\u67e5\uff1a\u786e\u8ba4\u6881\u4e0a\u5f00\u5b54\u4f4d\u7f6e\u3001\u5916\u673a\u5b89\u88c5\u4f4d\u7f6e\u3001\u51b7\u51dd\u6c34\u6392\u653e\u8def\u5f84\uff0c\u786e\u4fdd\u65b9\u6848\u53ef\u843d\u5730\u3002<\/div>\n        <div class=\"calc-step\"><span class=\"step-num\">4<\/span>\u6839\u636e\u6700\u7ec8\u786e\u8ba4\u65b9\u6848\uff0c\u51fa\u5177\u5b8c\u6574\u8bbe\u5907\u6e05\u5355\u53ca\u62a5\u4ef7\u3002<\/div>\n      <\/div>\n\n      <div style=\"margin-top:24px;padding:16px 22px;background:#fffde7;border-left:4px solid #fbc02d;border-radius:0 8px 8px 0;\">\n        <div style=\"font-weight:bold;color:#f57f17;margin-bottom:8px;\">\u26a0\ufe0f \u91cd\u8981\u63d0\u793a<\/div>\n        <p style=\"font-size:13px;color:#666;line-height:1.8;\">\n        \u672c\u65b9\u6848\u524d\u4e66\u4e3a\u521d\u6b65\u8bbe\u8ba1\u65b9\u6848\uff0c\u6700\u7ec8\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u6570\u636e\u548c\u8521\u5148\u751f\u786e\u8ba4\u7684\u9700\u6c42\u4e3a\u51c6\u3002\n        \u5185\u673a\u578b\u53f7\u4e3a\u65e5\u7acb\u7cfb\u7edf\u53c2\u8003\u578b\u53f7\uff0c\u5b9e\u9645\u9009\u7528\u65f6\u53ef\u6839\u636e\u54c1\u724c\u504f\u597d\u8c03\u6574\u3002\n        \u5730\u6696\u7cfb\u7edf\u9700\u5355\u72ec\u8bbe\u8ba1\uff0c\u5efa\u8bae\u7531\u4e13\u4e1a\u5730\u6696\u5de5\u7a0b\u5e08\u53e6\u884c\u51fa\u56fe\u3002\n        <\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u9875\u811a -->\n  <div class=\"footer\">\n    <div>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546<\/div>\n    <div style=\"margin-top:6px;\">\u65b9\u6848\u8bbe\u8ba1\uff1a\u9f99\u8109\u6696\u901a\u6280\u672f\u56e2\u961f &nbsp;|&nbsp; \u65b9\u6848\u65e5\u671f\uff1a2026\u5e746\u6708<\/div>\n    <div style=\"margin-top:6px;\">\u672c\u65b9\u6848\u524d\u4e66\u4f9d\u636e GB 50736-2012 \u53ca\u9f99\u8109\u6696\u901a\u6c1f\u7cfb\u7edf\u6280\u80fd\u5e93 V2.0 \u7f16\u5236<\/div>\n  <\/div>\n\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a  [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4257","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=4257\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=4257\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4257\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4257\",\"name\":\"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-22T15:44:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4257#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4257\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4257#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=4257","og_locale":"zh_CN","og_type":"article","og_title":"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=4257","og_site_name":"\u9f99\u8109\u6696\u901a","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=4257","url":"https:\/\/longmai-nt.com\/?page_id=4257","name":"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-22T15:44:40+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=4257#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=4257"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=4257#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u8521\u5148\u751f\u65b9\u6848\u524d\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4257"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4257\/revisions"}],"predecessor-version":[{"id":4258,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4257\/revisions\/4258"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}