{"id":4527,"date":"2026-06-25T18:16:11","date_gmt":"2026-06-25T10:16:11","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=4527"},"modified":"2026-06-25T18:16:12","modified_gmt":"2026-06-25T10:16:12","slug":"%e6%bd%98%e6%80%bb%e5%9c%b0%e6%9a%96%e6%96%b9%e6%a1%88%e5%89%8d%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=4527","title":{"rendered":"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66"},"content":{"rendered":"\n\n    \n    \n    \n    <style>\n    :root {\n        --orange: #e8581c;\n        --blue: #1a5fa8;\n        --green: #1a6e3a;\n        --gold: #b8860b;\n        --red: #c0392b;\n        --bg: #f8f6f2;\n        --card-bg: #fff;\n        --text: #222;\n        --text-light: #666;\n        --border: #e0d8cc;\n        --shadow: 0 2px 12px rgba(0, 0, 0, .08);\n        --radius: 10px;\n    }\n\n    *, * ::before, * ::after {\n        box-sizing: border-box;\n        margin: 0;\n        padding: 0\n    }\n\n    html {\n        scroll-behavior: smooth\n    }\n\n    body {\n        font-family: 'PingFang SC', 'Microsoft YaHei', sans-serif;\n        background: var(--bg);\n        color: var(--text);\n        line-height: 1.7;\n        font-size: 15px\n    }\/* \u2500\u2500 topbar \u2500\u2500 *\/\n    .topbar {\n        background: linear-gradient(135deg, #1a1a2e 0%, #16213e 60%, #0f3460 100%);\n        color: #fff;\n        padding: 10px 0;\n        position: sticky;\n        top: 0;\n        z-index: 100;\n        border-bottom: 2px solid var(--orange)\n    }\n\n    .topbar .wrap {\n        display: flex;\n        justify-content: space-between;\n        align-items: center;\n        flex-wrap: wrap;\n        gap: 6px\n    }\n\n    .topbar-brand {\n        font-size: 16px;\n        font-weight: 700;\n        letter-spacing: .05em\n    }\n\n    .topbar-brand span {\n        color: var(--orange)\n    }\n\n    .topbar-info {\n        font-size: 13px;\n        opacity: .85\n    }\/* \u2500\u2500 hero \u2500\u2500 *\/\n    .hero {\n        background: linear-gradient(135deg, #0f3460 0%, #1a5fa8 50%, #16213e 100%);\n        color: #fff;\n        padding: 36px 0 28px\n    }\n\n    .hero-title {\n        font-size: 26px;\n        font-weight: 800;\n        letter-spacing: .05em;\n        margin-bottom: 8px\n    }\n\n    .hero-title .ht {\n        color: var(--orange)\n    }\n\n    .hero-sub {\n        font-size: 14px;\n        opacity: .8;\n        margin-bottom: 20px\n    }\n\n    .hero-meta {\n        display: flex;\n        flex-wrap: wrap;\n        gap: 12px;\n        margin-bottom: 20px\n    }\n\n    .hero-meta-item {\n        background: rgba(255, 255, 255, .12);\n        border-radius: 8px;\n        padding: 10px 16px;\n        text-align: center;\n        min-width: 80px\n    }\n\n    .hero-meta-item .val {\n        font-size: 20px;\n        font-weight: 700;\n        color: #ffd700\n    }\n\n    .hero-meta-item .lbl {\n        font-size: 11px;\n        opacity: .75;\n        margin-top: 2px\n    }\n\n    .hero-badge {\n        display: inline-flex;\n        align-items: center;\n        gap: 6px;\n        background: rgba(232, 88, 28, .2);\n        border: 1px solid rgba(232, 88, 28, .5);\n        border-radius: 20px;\n        padding: 4px 14px;\n        font-size: 12px;\n        color: #ffd700;\n        margin-right: 8px;\n        margin-bottom: 4px\n    }\/* \u2500\u2500 \u6b65\u9aa4\u5bfc\u822a \u2500\u2500 *\/\n    .steps-nav {\n        background: #fff;\n        border-bottom: 2px solid var(--border);\n        position: sticky;\n        top: 48px;\n        z-index: 99;\n        padding: 0;\n        box-shadow: 0 2px 8px rgba(0, 0, 0, .06)\n    }\n\n    .steps-nav .wrap {\n        display: flex;\n        overflow-x: auto;\n        gap: 0\n    }\n\n    .step-tab {\n        flex-shrink: 0;\n        padding: 12px 18px;\n        font-size: 13px;\n        font-weight: 600;\n        color: var(--text-light);\n        border-bottom: 3px solid transparent;\n        cursor: pointer;\n        white-space: nowrap;\n        text-decoration: none;\n        transition: .2s\n    }\n\n    .step-tab:hover {\n        color: var(--blue)\n    }\n\n    .step-tab.s1 {\n        color:#c0392b\n    }\n\n    .step-tab.s1:hover, .step-tab.s1.active {\n        border-color: #c0392b;\n        background: rgba(192, 57, 43, .05)\n    }\n\n    .step-tab.s2 {\n        color:#8e44ad\n    }\n\n    .step-tab.s2:hover, .step-tab.s2.active {\n        border-color: #8e44ad;\n        background: rgba(142, 68, 173, .05)\n    }\n\n    .step-tab.s3 {\n        color:var(--blue)\n    }\n\n    .step-tab.s3:hover, .step-tab.s3.active {\n        border-color: var(--blue);\n        background: rgba(26, 95, 168, .05)\n    }\n\n    .step-tab.s4 {\n        color:var(--green)\n    }\n\n    .step-tab.s4:hover, .step-tab.s4.active {\n        border-color: var(--green);\n        background: rgba(26, 110, 58, .05)\n    }\n\n    .step-tab.s5 {\n        color:var(--gold)\n    }\n\n    .step-tab.s5:hover, .step-tab.s5.active {\n        border-color: var(--gold);\n        background: rgba(184, 134, 11, .05)\n    }\/* \u2500\u2500 wrap \u2500\u2500 *\/\n    .wrap {\n        max-width: 960px;\n        margin: 0 auto;\n        padding: 0 16px\n    }\/* \u2500\u2500 step section \u2500\u2500 *\/\n    .step-section {\n        padding: 32px 0\n    }\n\n    .step-header {\n        display: flex;\n        align-items: center;\n        gap: 12px;\n        margin-bottom: 20px\n    }\n\n    .step-num {\n        width: 40px;\n        height: 40px;\n        border-radius: 50%;\n        display: flex;\n        align-items: center;\n        justify-content: center;\n        font-size: 18px;\n        font-weight: 800;\n        color: #fff;\n        flex-shrink: 0\n    }\n\n    .step-num.c1 {\n        background: #c0392b\n    }\n\n    .step-num.c2 {\n        background: #8e44ad\n    }\n\n    .step-num.c3 {\n        background: var(--blue)\n    }\n\n    .step-num.c4 {\n        background: var(--green)\n    }\n\n    .step-num.c5 {\n        background: var(--gold)\n    }\n\n    .step-title {\n        font-size: 22px;\n        font-weight: 800\n    }\n\n    .step-desc {\n        font-size: 14px;\n        color: var(--text-light);\n        margin-top: 2px\n    }\/* \u2500\u2500 cards \u2500\u2500 *\/\n    .card {\n        background: var(--card-bg);\n        border-radius: var(--radius);\n        border: 1px solid var(--border);\n        padding: 20px;\n        margin-bottom: 16px;\n        box-shadow: var(--shadow)\n    }\n\n    .card h3 {\n        font-size: 16px;\n        font-weight: 700;\n        margin-bottom: 12px\n    }\n\n    .card.edge-r {\n        border-left: 4px solid var(--red)\n    }\n\n    .card.edge-o {\n        border-left: 4px solid var(--orange)\n    }\n\n    .card.edge-b {\n        border-left: 4px solid var(--blue)\n    }\n\n    .card.edge-g {\n        border-left: 4px solid var(--green)\n    }\n\n    .card.edge-gold {\n        border-left: 4px solid var(--gold)\n    }\n\n    .card.edge-purple {\n        border-left: 4px solid #8e44ad\n    }\n\n    .card.highlight-best {\n        border: 2px solid var(--green);\n        background: linear-gradient(135deg, #f0fff4 0%, #fff 100%)\n    }\/* \u2500\u2500 table \u2500\u2500 *\/\n    .tbl {\n        width: 100%;\n        border-collapse: collapse;\n        font-size: 13px\n    }\n\n    .tbl th {\n        background: #f0f4f8;\n        padding: 8px 10px;\n        text-align: left;\n        font-weight: 600;\n        border: 1px solid #ddd;\n        font-size: 12px\n    }\n\n    .tbl td {\n        padding: 7px 10px;\n        border: 1px solid #eee;\n        vertical-align: top\n    }\n\n    .tbl tr:nth-child(even) td {\n        background: #fafafa\n    }\n\n    .hi {\n        color: var(--green);\n        font-weight: 700\n    }\n\n    .bad {\n        color: var(--red)\n    }\/* \u2500\u2500 note \u2500\u2500 *\/\n    .note {\n        border-radius: 8px;\n        padding: 12px 16px;\n        margin: 12px 0;\n        font-size: 13px;\n        line-height: 1.8\n    }\n\n    .note.nb {\n        background: #e8f4fd;\n        border-left: 4px solid var(--blue)\n    }\n\n    .note.no {\n        background: #fff5ec;\n        border-left: 4px solid var(--orange)\n    }\n\n    .note.ng {\n        background: #e8f8ee;\n        border-left: 4px solid var(--green)\n    }\n\n    .note.nr {\n        background: #fdecea;\n        border-left: 4px solid var(--red)\n    }\n\n    .note.np {\n        background: #f5eeff;\n        border-left: 4px solid #8e44ad\n    }\n\n    .note.ngold {\n        background: #fffbec;\n        border-left: 4px solid var(--gold)\n    }\/* \u2500\u2500 grid \u2500\u2500 *\/\n    .grid-2 {\n        display: grid;\n        grid-template-columns: 1fr 1fr;\n        gap: 16px\n    }\n\n    .grid-3 {\n        display: grid;\n        grid-template-columns: repeat(3, 1fr);\n        gap: 16px\n    }\n\n    @media (max-width: 640px) {\n        .grid-2, .grid-3 {\n            grid-template-columns: 1fr\n        }\n    }\/* \u2500\u2500 pain cards \u2500\u2500 *\/\n    .pain-card {\n        background: #fff;\n        border-radius: 10px;\n        padding: 16px;\n        border: 1px solid #eee;\n        box-shadow: var(--shadow)\n    }\n\n    .pain-icon {\n        font-size: 24px;\n        margin-bottom: 8px\n    }\n\n    .pain-q {\n        font-size: 14px;\n        font-weight: 700;\n        color: var(--red);\n        margin-bottom: 6px\n    }\n\n    .pain-real {\n        font-size: 13px;\n        color: var(--blue);\n        font-weight: 600;\n        margin-bottom: 4px\n    }\n\n    .pain-sol {\n        font-size: 12px;\n        color: var(--text-light)\n    }\/* \u2500\u2500 \u65b9\u6848\u5361 \u2500\u2500 *\/\n    .plan-card {\n        background: #fff;\n        border-radius: 12px;\n        padding: 20px;\n        border: 2px solid var(--border);\n        box-shadow: var(--shadow);\n        position: relative\n    }\n\n    .plan-card.best {\n        border-color: var(--green);\n        background: linear-gradient(135deg, #f0fff4 0%, #fff 60%)\n    }\n\n    .plan-badge {\n        position: absolute;\n        top: -10px;\n        right: 14px;\n        background: var(--green);\n        color: #fff;\n        border-radius: 20px;\n        padding: 3px 12px;\n        font-size: 11px;\n        font-weight: 700\n    }\n\n    .plan-badge.warn {\n        background: var(--red)\n    }\n\n    .plan-name {\n        font-size: 16px;\n        font-weight: 800;\n        margin-bottom: 6px\n    }\n\n    .plan-price {\n        font-size: 22px;\n        font-weight: 800;\n        color: var(--orange);\n        margin: 8px 0\n    }\n\n    .plan-price small {\n        font-size: 13px;\n        color: var(--text-light);\n        font-weight: 400\n    }\n\n    .plan-tag {\n        display: inline-flex;\n        align-items: center;\n        gap: 4px;\n        background: #e8f4fd;\n        color: var(--blue);\n        border-radius: 12px;\n        padding: 3px 10px;\n        font-size: 11px;\n        margin: 2px\n    }\/* \u2500\u2500 \u6b65\u9aa4\u6d41 \u2500\u2500 *\/\n    .flow-steps {\n        display: flex;\n        flex-direction: column;\n        gap: 0\n    }\n\n    .flow-item {\n        display: flex;\n        gap: 16px;\n        padding: 16px 0;\n        border-bottom: 1px dashed var(--border)\n    }\n\n    .flow-item:last-child {\n        border-bottom: none\n    }\n\n    .flow-dot {\n        width: 32px;\n        height: 32px;\n        border-radius: 50%;\n        background: var(--blue);\n        color: #fff;\n        display: flex;\n        align-items: center;\n        justify-content: center;\n        font-weight: 700;\n        flex-shrink: 0;\n        font-size: 13px\n    }\n\n    .flow-content h4 {\n        font-size: 14px;\n        font-weight: 700;\n        margin-bottom: 4px\n    }\n\n    .flow-content p {\n        font-size: 13px;\n        color: var(--text-light);\n        line-height: 1.6\n    }\/* \u2500\u2500 \u5e74\u8d39\u6761 \u2500\u2500 *\/\n    .cost-bar {\n        height: 28px;\n        border-radius: 6px;\n        margin: 4px 0;\n        display: flex;\n        align-items: center;\n        padding: 0 10px;\n        font-size: 12px;\n        font-weight: 700;\n        color: #fff\n    }\/* \u2500\u2500 \u6848\u4f8b\u5361 \u2500\u2500 *\/\n    .case-card {\n        background: #fff;\n        border-radius: 12px;\n        padding: 18px;\n        border: 1px solid var(--border);\n        box-shadow: var(--shadow)\n    }\n\n    .case-tag {\n        display: inline-block;\n        background: var(--orange);\n        color: #fff;\n        border-radius: 4px;\n        padding: 2px 8px;\n        font-size: 11px;\n        margin-bottom: 8px\n    }\n\n    .case-star {\n        color: #f39c12;\n        font-size: 14px\n    }\/* \u2500\u2500 divider \u2500\u2500 *\/\n    .divider {\n        height: 1px;\n        background: linear-gradient(to right, transparent, var(--border), transparent);\n        margin: 24px 0\n    }\/* \u2500\u2500 ext-link \u2500\u2500 *\/\n    .ext-link {\n        color: var(--blue);\n        text-decoration: none;\n        border-bottom: 1px dashed var(--blue);\n        font-size: 13px\n    }\n\n    .ext-link:hover {\n        color: var(--orange)\n    }\/* \u2500\u2500 footer \u2500\u2500 *\/\n    .footer {\n        background: #1a1a2e;\n        color: #fff;\n        padding: 24px 0;\n        text-align: center;\n        font-size: 13px;\n        opacity: .9;\n        margin-top: 40px\n    }\n\n    .footer p {\n        margin: 4px 0\n    }\n\n    .footer strong {\n        color: var(--orange)\n    }\n    <\/style>\n\n    <!-- \u2500\u2500 TOPBAR \u2500\u2500 -->\n    <div class=\"topbar\">\n        <div class=\"wrap\">\n            <div class=\"topbar-brand\">\n                <span>\u9f99\u8109\u6696\u901a<\/span>\n                 \u00b7 \u4f59\u7231\u82f1 | \u65b9\u6848\u524d\u4e66\n            <\/div>\n            <div class=\"topbar-info\">\ud83d\udcf1 \u4f59\u7231\u82f1 13908183204 \u00b7 \u5357\u5bcc\u68ee3\u53f7\u697cA3347-348<\/div>\n        <\/div>\n    <\/div>\n\n    <!-- \u2500\u2500 HERO \u2500\u2500 -->\n    <div class=\"hero\">\n        <div class=\"wrap\">\n            <div class=\"hero-title\">\n                <span class=\"ht\">\u6f58\u603b<\/span>\n                 \u00b7 \u4e8c\u5c42\u6237\u578b \u00b7 \u5730\u6696\u65b9\u6848\u524d\u4e66\n                <small style=\"font-size:16px;font-weight:400;opacity:.8\">\uff08\u5347\u7ea7\u7248\uff09<\/small>\n            <\/div>\n            <div class=\"hero-sub\">\u9f99\u8109\u6696\u901a | 2004\u5e74\u6210\u7acb \u00b7 22\u5e74\u4e13\u6ce8\u6210\u90fd\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf<\/div>\n            <div class=\"hero-meta\">\n                <div class=\"hero-meta-item\">\n                    <div class=\"val\">115.87<\/div>\n                    <div class=\"lbl\">\u91c7\u6696\u9762\u79ef\u33a1<\/div>\n                <\/div>\n                <div class=\"hero-meta-item\">\n                    <div class=\"val\">2\u5c42<\/div>\n                    <div class=\"lbl\">\u6237\u578b\u5c42\u6570<\/div>\n                <\/div>\n                <div class=\"hero-meta-item\">\n                    <div class=\"val\">15kW<\/div>\n                    <div class=\"lbl\">\u8bbe\u8ba1\u8d1f\u8377<\/div>\n                <\/div>\n                <div class=\"hero-meta-item\">\n                    <div class=\"val\">5.8kW<\/div>\n                    <div class=\"lbl\">\u80fd\u8017\u8d1f\u8377<\/div>\n                <\/div>\n                <div class=\"hero-meta-item\">\n                    <div class=\"val\">29,570<\/div>\n                    <div class=\"lbl\">\u63a8\u8350\u65b9\u6848\u5143<\/div>\n                <\/div>\n            <\/div>\n            <div>\n                <span class=\"hero-badge\">\u2705 \u4fdd\u8bc1\u54c1\u8d28<\/span>\n                <span class=\"hero-badge\">\u2705 \u8003\u8651\u6027\u4ef7\u6bd4<\/span>\n                <span class=\"hero-badge\">\u2705 \u66fc\u745e\u5fb7\u51b7\u51dd\u7089+32+20\u8282\u80fd\u7ba1\u8def<\/span>\n                <span class=\"hero-badge\">\u2705 10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/span>\n            <\/div>\n        <\/div>\n    <\/div>\n\n    <!-- \u2500\u2500 \u6b65\u9aa4\u5bfc\u822a \u2500\u2500 -->\n    <nav class=\"steps-nav\">\n        <div class=\"wrap\">\n            <a href=\"#step1\" class=\"step-tab s1\">\u2460 \u9879\u76ee\u6982\u51b5\u4e0e\u9700\u6c42<\/a>\n            <a href=\"#step2\" class=\"step-tab s2\">\u2461 \u8bca\u65ad\u5206\u6790<\/a>\n            <a href=\"#step3\" class=\"step-tab s3\">\u2462 \u89e3\u51b3\u65b9\u6848<\/a>\n            <a href=\"#step4\" class=\"step-tab s4\">\u2463 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1<\/a>\n            <a href=\"#step5\" class=\"step-tab s5\">\u2464 \u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/a>\n        <\/div>\n    <\/nav>\n\n    <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n         \u7b2c\u4e00\u6b65\uff1a\u9879\u76ee\u6982\u51b5\u4e0e\u9700\u6c42\u75db\u70b9\n    \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n    <div class=\"step-section\" id=\"step1\" style=\"background:#fff9f7\">\n        <div class=\"wrap\">\n            <div class=\"step-header\">\n                <div class=\"step-num c1\">\u2460<\/div>\n                <div>\n                    <div class=\"step-title\" style=\"color:#c0392b\">\u9879\u76ee\u6982\u51b5 \u00b7 \u9700\u6c42\u786e\u8ba4<\/div>\n                    <div class=\"step-desc\">\u4e86\u89e3\u60a8\u7684\u5bb6 \u2014 \u9762\u79ef\u3001\u697c\u5c42\u3001\u75db\u70b9 \u00b7 \u7cbe\u51c6\u5b9a\u4f4d\u9700\u6c42<\/div>\n                <\/div>\n            <\/div>\n\n            <!-- \u57fa\u672c\u4fe1\u606f -->\n            <div class=\"grid-2\" style=\"margin-bottom:16px\">\n                <div class=\"card edge-r\">\n                    <h3>\ud83c\udfe0 \u9879\u76ee\u57fa\u7840\u4fe1\u606f<\/h3>\n                    <table class=\"tbl\">\n                        <tr>\n                            <td style=\"color:var(--text-light)\">\u5ba2\u6237<\/td>\n                            <td>\n                                <strong>\u6f58\u603b<\/strong>\n                            <\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--text-light)\">\u6237\u578b<\/td>\n                            <td>\u4e8c\u5c42\u6237\u578b\uff08\u8d1f\u4e00\u5c42 + \u4e00\u5c42 + \u4e8c\u5c42\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--text-light)\">\u91c7\u6696\u9762\u79ef<\/td>\n                            <td>\n                                <strong style=\"color:var(--orange)\">115.87\u33a1<\/strong>\n                            <\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--text-light)\">\u7f16\u5236\u65e5\u671f<\/td>\n                            <td>2026\u5e746\u670824\u65e5<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--text-light)\">\u65b9\u6848\u987e\u95ee<\/td>\n                            <td>\n                                <strong>\u9f99\u8109\u6696\u901a \u00b7 \u4f59\u7231\u82f1 13908183204<\/strong>\n                            <\/td>\n                        <\/tr>\n                    <\/table>\n                <\/div>\n                <div class=\"card edge-r\">\n                    <h3>\ud83d\udcd0 \u5404\u533a\u57df\u91c7\u6696\u9762\u79ef\u660e\u7ec6<\/h3>\n                    <table class=\"tbl\">\n                        <thead>\n                            <tr>\n                                <th>\u697c\u5c42\/\u533a\u57df<\/th>\n                                <th>\u9762\u79ef<\/th>\n                                <th>\u8bf4\u660e<\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr>\n                                <td>\u8d1f\u4e00\u5c42\u5927\u5385<\/td>\n                                <td>\n                                    <strong>26.69\u33a1<\/strong>\n                                <\/td>\n                                <td>\u5730\u4e0b\u7a7a\u95f4\u00b7\u70ed\u635f\u8f83\u5927<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u8d1f\u4e00\u5c42\u5367\u5ba4<\/td>\n                                <td>\n                                    <strong>10.00\u33a1<\/strong>\n                                <\/td>\n                                <td>\u5c0f\u623f\u95f4<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u4e00\u5c42\u5927\u5385<\/td>\n                                <td>\n                                    <strong>43.00\u33a1<\/strong>\n                                <\/td>\n                                <td>\u6700\u5927\u5f00\u9614\u7a7a\u95f4<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u4e00\u5c42\u6b21\u5367<\/td>\n                                <td>\n                                    <strong>12.90\u33a1<\/strong>\n                                <\/td>\n                                <td>\u2014<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u4e8c\u5c42\u4e3b\u5367<\/td>\n                                <td>\n                                    <strong>29.70\u33a1<\/strong>\n                                <\/td>\n                                <td>19.3+10.4\u33a1<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u4e8c\u5c42\u5367\u5ba41#<\/td>\n                                <td>\n                                    <strong>12.90\u33a1<\/strong>\n                                <\/td>\n                                <td>\u2014<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u4e8c\u5c42\u5367\u5ba42#+\u8fc7\u9053<\/td>\n                                <td>\n                                    <strong>17.37\u33a1<\/strong>\n                                <\/td>\n                                <td>\u542b\u8fc7\u9053\u9762\u79ef<\/td>\n                            <\/tr>\n                            <tr>\n                                <td colspan=\"1\" style=\"font-weight:700;color:var(--orange)\">\u5408\u8ba1<\/td>\n                                <td style=\"font-weight:700;color:var(--orange)\">152.56\u33a1<\/td>\n                                <td>\uff08\u5176\u4e2d\u6709\u6548\u91c7\u6696\u7ea6115.87\u33a1\uff09<\/td>\n                            <\/tr>\n                        <\/tbody>\n                    <\/table>\n                <\/div>\n            <\/div>\n\n            <!-- \u5ba2\u6237\u9700\u6c42 -->\n            <div class=\"card edge-r\" style=\"margin-bottom:16px\">\n                <h3>\ud83d\udcac \u5ba2\u6237\u6838\u5fc3\u9700\u6c42<\/h3>\n                <div class=\"grid-2\">\n                    <div>\n                        <p style=\"font-size:14px;font-weight:700;color:var(--red);margin-bottom:8px\">\u660e\u786e\u9700\u6c42\uff1a<\/p>\n                        <ul style=\"font-size:14px;line-height:2.2;padding-left:20px;\">\n                            <li>\n                                \u2705 \n                                <strong>\u4fdd\u8bc1\u54c1\u8d28<\/strong>\n                                \uff1a\u9009\u7528\u53ef\u9760\u54c1\u724c\u4e0e\u7ecf\u8fc7\u9a8c\u8bc1\u7684\u65b9\u6848\n                            <\/li>\n                            <li>\n                                \u2705 \n                                <strong>\u8003\u8651\u6027\u4ef7\u6bd4<\/strong>\n                                \uff1a\u5728\u54c1\u8d28\u524d\u63d0\u4e0b\u4e0d\u6d6a\u8d39\n                            <\/li>\n                            <li>\u2705 \u4e86\u89e3\u5730\u6696\u7cfb\u7edf\u5de5\u4f5c\u539f\u7406<\/li>\n                            <li>\u2705 \u4e86\u89e3\u5404\u79cd\u7ba1\u9053\u65b9\u6848\u7684\u533a\u522b<\/li>\n                            <li>\u2705 \u5bf9\u6bd4\u535a\u4e16 vs \u66fc\u745e\u5fb7\u51b7\u51dd\u7089<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div>\n                        <p style=\"font-size:14px;font-weight:700;color:var(--blue);margin-bottom:8px\">\u9879\u76ee\u7279\u70b9\uff1a<\/p>\n                        <ul style=\"font-size:14px;line-height:2.2;padding-left:20px;\">\n                            <li>\ud83c\udfd7\ufe0f \u4e8c\u5c42\u6237\u578b\uff0c\u70ed\u635f\u70b9\u591a\uff08\u8d1f\u4e00\u5c42+\u9876\u5c42\uff09<\/li>\n                            <li>\ud83c\udf21\ufe0f \u8bbe\u8ba1\u8d1f\u8377 15kW\uff08\u6700\u51b7\u5929\u5cf0\u503c\u9700\u6c42\uff09<\/li>\n                            <li>\u26a1 \u65e5\u5e38\u80fd\u8017\u8d1f\u8377\u4ec5 5.8kW\uff08\u5e73\u5747\u9700\u6c42\uff09<\/li>\n                            <li>\ud83d\udca7 \u9700\u8003\u86512\u4e2a\u4ee5\u4e0a\u7528\u6c34\u70b9\u540c\u65f6\u7528\u70ed\u6c34<\/li>\n                            <li>\ud83d\udcd0 115.87\u33a1\u9762\u79ef\uff0c\u7ba1\u8def\u9009\u578b\u5173\u952e<\/li>\n                        <\/ul>\n                    <\/div>\n                <\/div>\n            <\/div>\n\n            <!-- \u62c5\u5fc3\u7684\u75db\u70b9 -->\n            <h3 style=\"font-size:16px;font-weight:700;margin-bottom:12px\">\ud83d\udd0d \u5ba2\u6237\u7684\u4e09\u5927\u62c5\u5fc3\u75db\u70b9<\/h3>\n            <div class=\"grid-3\">\n                <div class=\"pain-card\">\n                    <div class=\"pain-icon\">\ud83d\udcb0<\/div>\n                    <div class=\"pain-q\">\u300c\u5730\u6696\u60f3\u88c5\uff0c\u4f46\u6015\u8d39\u94b1\u300d<\/div>\n                    <div class=\"pain-real\">\u771f\u6b63\u5173\u5fc3\uff1a\u88c5\u5f97\u8d77\u8fd8\u80fd\u70e7\u5f97\u8d77\u5417\uff1f<\/div>\n                    <div class=\"pain-sol\">\u89e3\u51b3\u65b9\u6848\uff1a\u51b7\u51dd\u7089+32+20\u5927\u6d41\u91cf\u7ba1\u8def\u8054\u52a8\uff0c\u5b63\u8d39\u7528\u964d\u81f31,000\u5143\u4ee5\u4e0a\u8282\u7701<\/div>\n                <\/div>\n                <div class=\"pain-card\">\n                    <div class=\"pain-icon\">\u2744\ufe0f<\/div>\n                    <div class=\"pain-q\">\u300c\u670b\u53cb\u5bb6\u5730\u6696\u6548\u679c\u4e0d\u597d\u300d<\/div>\n                    <div class=\"pain-real\">\u771f\u6b63\u5173\u5fc3\uff1a\u88c5\u4e86\u4e5f\u548c\u6ca1\u88c5\u4e00\u6837\uff1f<\/div>\n                    <div class=\"pain-sol\">\u89e3\u51b3\u65b9\u6848\uff1aDe32\u4e3b\u7ba1\u6d41\u91cf\u63d0\u5347100%\uff0c\u5168\u5c4b\u5747\u5300\u4f9b\u70ed\uff0c\u5f7b\u5e95\u907f\u514d\u8fdc\u7aef\u4e0d\u70ed<\/div>\n                <\/div>\n                <div class=\"pain-card\">\n                    <div class=\"pain-icon\">\ud83e\udd14<\/div>\n                    <div class=\"pain-q\">\u300c\u9505\u7089\u54c1\u724c\u600e\u4e48\u9009\uff1f\u300d<\/div>\n                    <div class=\"pain-real\">\u771f\u6b63\u5173\u5fc3\uff1a\u535a\u4e16 vs \u66fc\u745e\u5fb7\uff0c\u8c01\u66f4\u9002\u5408\u6211\u5bb6\uff1f<\/div>\n                    <div class=\"pain-sol\">\u89e3\u51b3\u65b9\u6848\uff1a\u8be6\u7ec6\u53c2\u6570\u5bf9\u6bd4\uff0c\u66fc\u745e\u5fb7\u6700\u5c0f\u8f93\u51fa4kW\u5b8c\u7f8e\u5339\u914d5.8kW\u80fd\u8017\u8d1f\u8377<\/div>\n                <\/div>\n            <\/div>\n\n        <\/div>\n    <\/div>\n\n    <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n         \u7b2c\u4e8c\u6b65\uff1a\u8bca\u65ad\u5206\u6790\n    \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n    <div class=\"step-section\" id=\"step2\" style=\"background:#f9f5ff\">\n        <div class=\"wrap\">\n            <div class=\"step-header\">\n                <div class=\"step-num c2\">\u2461<\/div>\n                <div>\n                    <div class=\"step-title\" style=\"color:#8e44ad\">\u8bca\u65ad\u5206\u6790 \u00b7 \u900f\u89c6\u9700\u6c42\u672c\u8d28<\/div>\n                    <div class=\"step-desc\">\u663e\u6027\u9700\u6c42 vs \u9690\u6027\u9700\u6c42 \u00b7 \u8bbe\u8ba1\u8d1f\u8377 vs \u80fd\u8017\u8d1f\u8377 \u00b7 \u74f6\u9888\u5728\u54ea\u91cc<\/div>\n                <\/div>\n            <\/div>\n\n            <!-- \u4e24\u4e2a\u5173\u952e\u6982\u5ff5 -->\n            <div class=\"note np\" style=\"margin-bottom:16px\">\n                <strong>\ud83d\udcca \u5148\u7406\u89e3\u4e24\u4e2a\u5173\u952e\u6982\u5ff5\uff0c\u624d\u80fd\u8bfb\u61c2\u540e\u9762\u7684\u65b9\u6848<\/strong>\n                <br>\n\n                      \u5f88\u591a\u4eba\u4e70\u9505\u7089\u53ea\u770b\"\u989d\u5b9a\u529f\u7387\"\uff0c\u5176\u5b9e\u66f4\u5173\u952e\u7684\u662f\uff1a\n                <strong>\u2460 \u4f60\u5bb6\u5b9e\u9645\u9700\u8981\u591a\u5c11\u70ed\u91cf\uff08\u5cf0\u503c vs \u5e73\u5747\uff09\u2461 \u7ba1\u8def\u80fd\u5426\u628a\u70ed\u91cf\u9001\u5230\u6bcf\u4e2a\u623f\u95f4<\/strong>\n            <\/div>\n\n            <div class=\"grid-2\" style=\"margin-bottom:16px\">\n                <div class=\"card edge-purple\">\n                    <h3>\ud83d\udcc8 \u8bbe\u8ba1\u8d1f\u8377 \u00b7 \u5cf0\u503c\u529f\u7387<\/h3>\n                    <div style=\"font-size:28px;font-weight:800;color:#8e44ad;text-align:center;padding:12px 0\">15 kW<\/div>\n                    <p style=\"font-size:13px;line-height:1.8;color:var(--text-light)\">\n\n                                  \u6ee1\u8db3\n                        <strong>\u6700\u51b7\u90a3\u51e0\u5929<\/strong>\n                        \u9700\u6c42\u7684\u5cf0\u503c\u529f\u7387\u3002\u597d\u6bd4\u4e70\u8f66\u8003\u8651\u6ee1\u8f7d\u4e0a\u5761\u7684\u52a8\u529b\u2014\u2014\u4e0d\u662f\u6bcf\u5929\u90fd\u7528\uff0c\u4f46\u5173\u952e\u65f6\u523b\u8981\u6709\u3002\n                        <br>\n                        <strong style=\"color:#8e44ad\">\u4f5c\u7528\uff1a<\/strong>\n                        \u51b3\u5b9a\u9505\u7089\u989d\u5b9a\u529f\u7387\u9009\u578b\uff08\u4e70\u9505\u7089\u6309\u8fd9\u4e2a\u7b97\uff09\n                                \n                    <\/p>\n                <\/div>\n                <div class=\"card edge-purple\">\n                    <h3>\u26a1 \u80fd\u8017\u8d1f\u8377 \u00b7 \u5e73\u5747\u529f\u7387<\/h3>\n                    <div style=\"font-size:28px;font-weight:800;color:var(--blue);text-align:center;padding:12px 0\">5.8 kW<\/div>\n                    <p style=\"font-size:13px;line-height:1.8;color:var(--text-light)\">\n\n                                  \u6574\u4e2a\u91c7\u6696\u5b63\u7684\n                        <strong>\u5e73\u5747\u70ed\u8d1f\u8377<\/strong>\n                        \u3002\u7b97\u6cb9\u8d39\uff08\u71c3\u6c14\u8d39\uff09\u6309\u8fd9\u4e2a\u7b97\u2014\u2014\u9505\u7089\u5927\u591a\u6570\u65f6\u95f4\u57285.8kW\u9644\u8fd1\u8fd0\u884c\u3002\n                        <br>\n                        <strong style=\"color:var(--blue)\">\u4f5c\u7528\uff1a<\/strong>\n                        \u51b3\u5b9a\u7ba1\u8def\u9009\u578b\uff08\u7ba1\u9053\u6309\u8fd9\u4e2a\u5339\u914d\u624d\u8282\u80fd\uff09\n                                \n                    <\/p>\n                <\/div>\n            <\/div>\n\n            <!-- \u6838\u5fc3\u8bca\u65ad\uff1a\u4e3a\u4ec0\u4e48De25\u662f\u95ee\u9898\u6240\u5728 -->\n            <div class=\"card edge-r\">\n                <h3 style=\"color:var(--red)\">\u26a0\ufe0f \u6838\u5fc3\u8bca\u65ad\uff1aDe25\u4e3b\u7ba1 = \"\u74f6\u9888\"\uff0c\u5bfc\u81f4\u9505\u7089\u9891\u7e41\u542f\u505c<\/h3>\n                <div class=\"note nr\">\n                    <strong>\u95ee\u9898\u94fe\u6761\uff1a<\/strong>\n                    De25\u4e3b\u7ba1\u6700\u5927\u6d41\u91cf\u7ea6500 L\/h\uff0c\u70ed\u4f20\u8f93\u80fd\u529b\u4ec55.8kW \u2192 \u4e0e\u80fd\u8017\u8d1f\u8377\u6301\u5e73\uff0c\n                    <strong>\u6ca1\u6709\u4f59\u91cf<\/strong>\n                     \u2192 \u70ed\u91cf\u9001\u4e0d\u51fa\u53bb \u2192 \u9505\u7089\u618b\u538b\u9891\u7e41\u542f\u505c \u2192 \u5ba4\u6e29\u8fbe\u6807\u505c\u673a \u2192 \u518d\u542f\u52a8 \u2192 \u6d6a\u8d39\u71c3\u6c14\n                          \n                <\/div>\n                <div style=\"overflow-x:auto\">\n                    <table class=\"tbl\" style=\"margin-top:12px\">\n                        <thead>\n                            <tr>\n                                <th>\u7ba1\u8def\u65b9\u6848<\/th>\n                                <th>\u6700\u5927\u6d41\u91cf<\/th>\n                                <th>\u70ed\u4f20\u8f93\u80fd\u529b<\/th>\n                                <th>vs \u80fd\u8017\u9700\u6c425.8kW<\/th>\n                                <th>\u9505\u7089\u8fd0\u884c\u72b6\u6001<\/th>\n                                <th>\u4f9b\u6c34\u6e29\u5ea6\u9700\u6c42<\/th>\n                                <th>\u5b63\u8d39\u7528<\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr>\n                                <td>\n                                    <span class=\"bad\">\u274c De25+16<\/span>\n                                    \uff08\u5e02\u573a\u901a\u914d\uff09\n                                <\/td>\n                                <td>\u7ea6500 L\/h<\/td>\n                                <td class=\"bad\">\u7ea65.8 kW<\/td>\n                                <td class=\"bad\">\u4e34\u754c\uff0c\u65e0\u4f59\u91cf<\/td>\n                                <td class=\"bad\">\u9891\u7e41\u542f\u505c<\/td>\n                                <td class=\"bad\">\u970060-65\u2103<\/td>\n                                <td class=\"bad\">3,800-4,500\u5143<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\n                                    <span class=\"hi\">\u2705 De32+20<\/span>\n                                    \uff08\u8282\u80fd\u5b9a\u5236\uff09\n                                <\/td>\n                                <td>\u7ea61,000 L\/h<\/td>\n                                <td class=\"hi\">\u7ea611.6 kW<\/td>\n                                <td class=\"hi\">\n                                    <strong>\u5145\u8db3\u4f59\u91cf+100%<\/strong>\n                                <\/td>\n                                <td class=\"hi\">\u5e73\u7a33\u8fd0\u884c<\/td>\n                                <td class=\"hi\">\u4ec5\u970055-60\u2103<\/td>\n                                <td class=\"hi\">3,000-3,600\u5143<\/td>\n                            <\/tr>\n                        <\/tbody>\n                    <\/table>\n                <\/div>\n                <div class=\"note ng\" style=\"margin-top:12px\">\n                    <strong>\ud83d\udca1 \u6838\u5fc3\u903b\u8f91\uff1a<\/strong>\n                    \u7ba1\u9053\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u88c5\u5b8c\u5c31\u6539\u4e0d\u4e86\u3002\u73b0\u5728\u591a\u82b11,800\u5143\u9009De32\uff0c\u6bcf\u5e74\u7701800-900\u5143\u71c3\u6c14\u8d39\uff0c\n                    <strong>\u4e0d\u52302\u5e74\u56de\u672c\uff0c\u4e4b\u540e\u6bcf\u5e74\u7eaf\u7701<\/strong>\n                    \u3002\n                          \n                <\/div>\n            <\/div>\n\n            <!-- \u663e\u6027 vs \u9690\u6027\u9700\u6c42 -->\n            <div class=\"card edge-purple\">\n                <h3>\ud83d\udd0d \u663e\u6027\u9700\u6c42 vs \u9690\u6027\u9700\u6c42 \u00b7 \u8bca\u65ad\u603b\u7ed3<\/h3>\n                <table class=\"tbl\">\n                    <thead>\n                        <tr>\n                            <th>\u9700\u6c42\u7c7b\u578b<\/th>\n                            <th>\u5ba2\u6237\u8868\u8fbe<\/th>\n                            <th>\u6df1\u5c42\u8bc9\u6c42<\/th>\n                            <th>\u6211\u4eec\u7684\u89e3\u7b54<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>\n                                <strong style=\"color:var(--red)\">\u663e\u6027\u9700\u6c42\u2460<\/strong>\n                            <\/td>\n                            <td>\u60f3\u88c5\u5730\u6696\uff0c\u8003\u8651\u6027\u4ef7\u6bd4<\/td>\n                            <td>\u521d\u6295\u8d44\u4f4e + \u7528\u7740\u7701<\/td>\n                            <td>\u65b9\u6848B\uff1a\u521d\u6295\u8d4429,570\u5143\uff0c\u5e74\u7701800-900\u5143\uff0c\u4e0d\u52302\u5e74\u56de\u672c<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong style=\"color:var(--red)\">\u663e\u6027\u9700\u6c42\u2461<\/strong>\n                            <\/td>\n                            <td>\u5bf9\u6bd4\u535a\u4e16 vs \u66fc\u745e\u5fb7<\/td>\n                            <td>\u9009\u5bf9\u54c1\u724c\u522b\u82b1\u51a4\u6789\u94b1<\/td>\n                            <td>\u66fc\u745e\u5fb7\u6700\u5c0f\u8f93\u51fa4kW\u66f4\u5339\u914d5.8kW\u8d1f\u8377\uff0c\u535a\u4e165-7kW\u4ecd\u53ef\u80fd\u9891\u7e41\u542f\u505c<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong style=\"color:#8e44ad\">\u9690\u6027\u9700\u6c42\u2460<\/strong>\n                            <\/td>\n                            <td>\u670b\u53cb\u5bb6\u5730\u6696\u6548\u679c\u4e0d\u597d<\/td>\n                            <td>\u6015\u6295\u5165\u4e86\u6ca1\u6548\u679c<\/td>\n                            <td>De32\u6d41\u91cf\u7ffb\u500d\uff0c\u5168\u5c4b\u5747\u6e29\uff0c\u6d88\u9664\u8fdc\u7aef\u4e0d\u70ed\u7684\u6839\u672c\u539f\u56e0<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong style=\"color:#8e44ad\">\u9690\u6027\u9700\u6c42\u2461<\/strong>\n                            <\/td>\n                            <td>\u672a\u8bf4\u4f46\u5b58\u5728<\/td>\n                            <td>\u5b89\u88c5\u540e\u4e0d\u7528\u64cd\u5fc3<\/td>\n                            <td>5\u5e74\u65bd\u5de5\u8d28\u4fdd + 10\u5e74\u80fd\u8017\u8ddf\u8e2a + \u7ec8\u8eab\u6280\u672f\u652f\u6301<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong style=\"color:#8e44ad\">\u9690\u6027\u9700\u6c42\u2462<\/strong>\n                            <\/td>\n                            <td>\u672a\u8bf4\u4f46\u5b58\u5728<\/td>\n                            <td>\u4e0d\u60f3\u88ab\u5751\u3001\u4e0d\u88ab\u589e\u9879<\/td>\n                            <td>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb\uff0c\u65e0\u9690\u85cf\u589e\u9879\uff0c\u6240\u6709\u8d39\u7528\u4e00\u6b21\u8bf4\u6e05<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n        <\/div>\n    <\/div>\n\n    <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n         \u7b2c\u4e09\u6b65\uff1a\u89e3\u51b3\u65b9\u6848\n    \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n    <div class=\"step-section\" id=\"step3\" style=\"background:#f0f8ff\">\n        <div class=\"wrap\">\n            <div class=\"step-header\">\n                <div class=\"step-num c3\">\u2462<\/div>\n                <div>\n                    <div class=\"step-title\" style=\"color:var(--blue)\">\u89e3\u51b3\u65b9\u6848 \u00b7 \u4ea7\u54c1\u00b7\u62a5\u4ef7\u00b7\u5bf9\u6bd4\u00b7\u6210\u672c<\/div>\n                    <div class=\"step-desc\">\u4e09\u5957\u53ef\u9009\u65b9\u6848 \u00b7 \u9505\u7089\u8be6\u7ec6\u5bf9\u6bd4 \u00b7 20\u5e74\u5168\u5468\u671f\u6210\u672c\u5206\u6790<\/div>\n                <\/div>\n            <\/div>\n\n            <!-- 3.1 \u4ea7\u54c1\u4ecb\u7ecd\uff1a\u4e24\u6b3e\u9505\u7089 -->\n            <h3 style=\"font-size:17px;font-weight:700;margin-bottom:14px;color:var(--blue)\">3.1 \u4ea7\u54c1\u4ecb\u7ecd \u00b7 \u4e24\u6b3e\u63a8\u8350\u9505\u7089<\/h3>\n\n            <div class=\"grid-2\" style=\"margin-bottom:16px\">\n                <!-- \u535a\u4e16 -->\n                <div class=\"card edge-b\">\n                    <h3 style=\"color:var(--blue)\">\u535a\u4e16 Condens 3260W \u00b7 25kW<\/h3>\n                    <p style=\"font-size:12px;color:var(--text-light);margin-bottom:10px\">\u5168\u9884\u6df7\u51b7\u51dd \u00b7 \u5fb7\u56fd\u535a\u4e16 \u00b7 \u56fd\u4ea7\u5236\u9020<\/p>\n                    <table class=\"tbl\">\n                        <tr>\n                            <td>\u6280\u672f\u7c7b\u578b<\/td>\n                            <td class=\"hi\">\u5168\u9884\u6df7\u51b7\u51dd<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u989d\u5b9a\u70ed\u529f\u7387<\/td>\n                            <td>25 kW<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u4f9b\u6696\u6700\u5c0f\u8f93\u51fa<\/td>\n                            <td>\u9884\u8ba1 5-7 kW<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u4e00\u7ea7\u80fd\u6548<\/td>\n                            <td class=\"hi\">\u7ea6103%-105%<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u751f\u6d3b\u70ed\u6c34\u4ea7\u7387<\/td>\n                            <td class=\"hi\">\u7ea614.3 L\/min<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u6838\u5fc3\u90e8\u4ef6<\/td>\n                            <td>\u6cd5\u56fdSERMETA + \u7f8e\u56fdResideo + \u4e39\u9ea6\u683c\u5170\u5bcc<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u667a\u80fd\u7269\u8054<\/td>\n                            <td>AI\u7701\u71c3\u6c14+APP\u8fdc\u7a0b+\u4e91\u670d\u52a1\uff08\u6807\u914d\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u8d28\u4fdd\u653f\u7b56<\/td>\n                            <td>\u4ee5\u6362\u4ee3\u4fee\uff0c5\u5e74\u4fdd\u4fee\uff08\u914d\u4ef6\u514d\u8d39\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--orange)\">\u53c2\u8003\u4ef7\u683c<\/td>\n                            <td style=\"color:var(--orange);font-weight:700\">9,575\u5143\uff08\u6709\u56fd\u8865\uff09<\/td>\n                        <\/tr>\n                    <\/table>\n                    <div class=\"note nb\" style=\"margin-top:10px\">\n                        <strong>\u535a\u4e16\u7279\u70b9\uff1a<\/strong>\n                        \u5fb7\u7cfb\u54c1\u8d28\u00b7\u6b27\u6d32\u8fdb\u53e3\u914d\u4ef6\u7ec4\u5408\u00b7AI\u667a\u80fd\u8282\u80fd\u00b715.5L\/min\u70ed\u6c34\u4ea7\u7387\u66f4\u5927\u00b7\u6807\u914dAPP\u8fdc\u7a0b\u63a7\u5236\u00b7\u4ee5\u6362\u4ee3\u4fee\u8d28\u4fdd\u4f53\u7cfb\u3002\u9002\u5408\u91cd\u89c6\u667a\u80fd\u5316\u548c\u70ed\u6c34\u91cf\u7684\u5ba2\u6237\u3002\n                                \n                    <\/div>\n                <\/div>\n                <!-- \u66fc\u745e\u5fb7 -->\n                <div class=\"card highlight-best\">\n                    <h3 style=\"color:var(--green)\">\n                        \ud83d\udd25 \u66fc\u745e\u5fb7\u5361\u8bfa \u51b7\u51dd24kW \n                        <span style=\"background:var(--green);color:#fff;border-radius:4px;padding:2px 8px;font-size:11px;margin-left:6px\">\u63a8\u8350<\/span>\n                    <\/h3>\n                    <p style=\"font-size:12px;color:var(--text-light);margin-bottom:10px\">\u72ec\u7acb\u51b7\u51dd\u5ba4+\u53cc\u91cd\u6362\u70ed \u00b7 \u5168\u9884\u6df7\u51b7\u51dd \u00b7 \u56fd\u4ea7\u5236\u9020<\/p>\n                    <table class=\"tbl\">\n                        <tr>\n                            <td>\u6280\u672f\u7c7b\u578b<\/td>\n                            <td class=\"hi\">\u5168\u9884\u6df7\u51b7\u51dd\uff08\u72ec\u7acb\u51b7\u51dd\u5ba4+\u53cc\u91cd\u6362\u70ed\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u989d\u5b9a\u70ed\u529f\u7387<\/td>\n                            <td>24 kW<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u4f9b\u6696\u6700\u5c0f\u8f93\u51fa<\/td>\n                            <td class=\"hi\">\n                                <strong>4 kW\uff08\u5b8c\u7f8e\u5339\u914d5.8kW\u80fd\u8017\u8d1f\u8377\uff09<\/strong>\n                            <\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u4e00\u7ea7\u80fd\u6548<\/td>\n                            <td class=\"hi\">108%\uff08\u66f4\u7701\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u751f\u6d3b\u70ed\u6c34\u4ea7\u7387<\/td>\n                            <td class=\"hi\">15.5 L\/min\uff08\u6ee1\u8db32\u4e2a\u9f99\u5934\u540c\u65f6\u7528\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u6838\u5fc3\u90e8\u4ef6<\/td>\n                            <td>AI\u7701\u71c3\u6c14+APP\u8fdc\u7a0b+\u4e91\u670d\u52a1\uff08\u6807\u914d\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u8d28\u4fdd\u653f\u7b56<\/td>\n                            <td class=\"hi\">\u9f99\u8109\u6696\u901a\u4f1a\u5458\u5e38\u89c4\u8d28\u4fdd \u00b7 5\u5e74\u4fdd\u4fee<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--orange)\">\u53c2\u8003\u4ef7\u683c<\/td>\n                            <td style=\"color:var(--orange);font-weight:700\">10,900\u5143\uff08\u6709\u56fd\u8865\uff0c\u8d351,325\u5143\uff09<\/td>\n                        <\/tr>\n                    <\/table>\n                    <div class=\"note ng\" style=\"margin-top:10px\">\n                        <strong>\u66fc\u745e\u5fb7\u4f18\u52bf\uff1a<\/strong>\n                        \u6700\u5c0f\u8f93\u51fa4kW\uff0c\n                        <strong>\u5b8c\u7f8e\u5339\u914d\u60a8\u5bb65.8kW\u80fd\u8017\u8d1f\u8377<\/strong>\n                        \uff0c\u9505\u7089\u4e0d\u4f1a\u9891\u7e41\u542f\u505c\u3002\u70ed\u6548\u7387108%\u6700\u7701\u71c3\u6c14\uff0c\u6bcf\u5e74\u591a\u7701500-1,000\u5143\u3002\u4e24\u5e74\u5185\u8d5a\u56de\u5dee\u4ef7\uff0c\u4e4b\u540e\u6bcf\u5e74\u7eaf\u7701\u3002\n                                \n                    <\/div>\n                <\/div>\n            <\/div>\n\n            <!-- 3.2 \u4e3a\u4ec0\u4e48\u66fc\u745e\u5fb7\u66f4\u9002\u5408 -->\n            <div class=\"card edge-g\" style=\"margin-bottom:16px\">\n                <h3 style=\"color:var(--green)\">\ud83c\udfaf \u4e3a\u4ec0\u4e48\u66fc\u745e\u5fb7\u66f4\u9002\u5408\u60a8\u5bb6\uff1f\u2014 \u7cbe\u51c6\u6570\u5b57\u8bf4\u8bdd<\/h3>\n                <table class=\"tbl\">\n                    <thead>\n                        <tr>\n                            <th>\u5bf9\u6bd4\u9879<\/th>\n                            <th>\u535a\u4e16 Condens 3260W\uff0825kW\uff09<\/th>\n                            <th class=\"hi\">\u66fc\u745e\u5fb7\u5361\u8bfa\u51b7\u51dd\uff0824kW\uff09<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>\u6700\u5c0f\u8f93\u51fa<\/td>\n                            <td class=\"bad\">5-7kW\uff08\u4ecd\u53ef\u80fd\u9891\u7e41\u542f\u505c\uff09<\/td>\n                            <td class=\"hi\">\n                                <strong>4kW\uff08\u5b8c\u7f8e\u5339\u914d\uff0c\u4e0d\u542f\u505c\uff09<\/strong>\n                            <\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u70ed\u6548\u7387<\/td>\n                            <td>103-105%<\/td>\n                            <td class=\"hi\">108%\uff08\u6700\u7701\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u70ed\u6c34\u4ea7\u7387<\/td>\n                            <td>14.3 L\/min<\/td>\n                            <td class=\"hi\">15.5 L\/min\uff08\u591a1.2\u5347\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u6bcf\u5e74\u7701\u71c3\u6c14<\/td>\n                            <td>\u2014\u57fa\u51c6\u2014<\/td>\n                            <td class=\"hi\">\u591a\u7701500-1,000\u5143\/\u5e74<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u53c2\u8003\u4ef7\u683c\uff08\u6709\u8865\u8d34\uff09<\/td>\n                            <td>9,575\u5143<\/td>\n                            <td>10,900\u5143\uff08\u8d351,325\u5143\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>2\u5c42\u6237\u578b\u70ed\u635f\u70b9<\/td>\n                            <td>5-7kW\u4ecd\u504f\u9ad8<\/td>\n                            <td class=\"hi\">4kW\u5b8c\u7f8e\u8986\u76d6\u4f4e\u8d1f\u8377\u533a\u95f4<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>5\u5e74\u8d28\u4fdd<\/td>\n                            <td>\u4ee5\u6362\u4ee3\u4fee\u4f53\u7cfb<\/td>\n                            <td class=\"hi\">\u9f99\u8109\u6696\u901a\u4f1a\u5458\u4fdd\u969c<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong>\u7efc\u5408\u8bc4\u4ef7<\/strong>\n                            <\/td>\n                            <td>\u4f18\u79c0\uff0c\u9002\u5408\u91cd\u89c6\u70ed\u6c34\u548c\u667a\u80fd\u5316<\/td>\n                            <td class=\"hi\">\n                                <strong>\u9996\u9009\uff0c\u6700\u5339\u914d\u60a8\u5bb65.8kW\u8d1f\u8377<\/strong>\n                            <\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                <div class=\"note ng\" style=\"margin-top:12px\">\n                    <strong>\u4e00\u53e5\u8bdd\u7ed3\u8bba\uff1a<\/strong>\n                    \u535a\u4e16\u4fbf\u5b9c1,325\u5143\uff0c\u4f46\u66fc\u745e\u5fb7\u6bcf\u5e74\u7701500-1,000\u5143\u71c3\u6c14\u8d39 \u2192 \n                    <strong>\u4e0d\u52302\u5e74\u5c31\u8d5a\u56de\u5dee\u4ef7<\/strong>\n                    \uff0c\u4e4b\u540e\u6bcf\u5e74\u7eaf\u7701\uff0c\u8fd8\u67095\u5e74\u8d28\u4fdd\u515c\u5e95\u3002\n                          \n                <\/div>\n            <\/div>\n\n            <!-- 3.3 \u4e09\u5957\u5b8c\u6574\u65b9\u6848\u914d\u7f6e -->\n            <h3 style=\"font-size:17px;font-weight:700;margin-bottom:14px;color:var(--blue)\">3.2 \u4e09\u5957\u65b9\u6848\u914d\u7f6e \u00b7 \u8bbe\u8ba1\u4f9d\u636e\u4e0e\u62a5\u4ef7<\/h3>\n            <div class=\"note nb\" style=\"margin-bottom:14px\">\n                <strong>\ud83d\udcd0 \u8bbe\u8ba1\u4f9d\u636e\uff1a<\/strong>\n                115.87\u33a1\u4e8c\u5c42\u6237\u578b\uff0c\u80fd\u8017\u8d1f\u83775.8kW\u3002\n                <strong>\u7ba1\u9053\u8bbe\u8ba1\u539f\u5219\uff1a<\/strong>\n                \u7ba1\u8def\u70ed\u4f20\u8f93\u80fd\u529b\u5fc5\u987b\u5927\u4e8e\u80fd\u8017\u8d1f\u8377\uff0c\u9884\u7559\u5145\u8db3\u4f59\u91cf\uff0c\u9505\u7089\u624d\u80fd\u5e73\u7a33\u8fd0\u884c\u4e0d\u9891\u7e41\u542f\u505c\u3002\n                    \n            <\/div>\n\n            <div class=\"grid-3\" style=\"margin-bottom:16px\">\n                <!-- \u65b9\u6848B\uff08\u63a8\u8350\uff09 -->\n                <div class=\"plan-card best\">\n                    <div class=\"plan-badge\">\ud83d\udd25 \u5f3a\u70c8\u63a8\u8350<\/div>\n                    <div class=\"plan-name\" style=\"color:var(--green)\">\u65b9\u6848 B<\/div>\n                    <div style=\"font-size:13px;color:var(--text-light);margin-bottom:8px\">\u66fc\u745e\u5fb7\u5361\u8bfa 24kW + 32+20\u8282\u80fd\u7ba1\u8def<\/div>\n                    <div class=\"plan-price\">\n                        \u00a529,570 \n                        <small>\u51cf\u56fd\u8865\u00a51,500\u540e<\/small>\n                    <\/div>\n                    <div>\n                        <span class=\"plan-tag\">\u2705 \u6700\u5339\u914d\u8d1f\u8377<\/span>\n                        <span class=\"plan-tag\">\u2705 \u6700\u7701\u71c3\u6c14<\/span>\n                        <span class=\"plan-tag\">\u2705 \u5145\u8db3\u70ed\u6c34<\/span>\n                        <span class=\"plan-tag\">\u2705 \u8282\u80fd\u7ba1\u8def<\/span>\n                    <\/div>\n                    <table class=\"tbl\" style=\"margin-top:12px\">\n                        <tr>\n                            <td>\u9505\u7089<\/td>\n                            <td>\u66fc\u745e\u5fb7\u5361\u8bfa24kW<\/td>\n                            <td class=\"hi\">10,900\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u7ba1\u8def<\/td>\n                            <td>32\u4e3b\u7ba1+20\u76d8\u7ba1<\/td>\n                            <td class=\"hi\">\u7ea619,570\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u5b89\u88c5\u8d39<\/td>\n                            <td>\u9505\u7089\u5b89\u88c5<\/td>\n                            <td>600\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"font-weight:700\">\u5408\u8ba1\uff08\u51cf\u8865\u8d34\uff09<\/td>\n                            <td><\/td>\n                            <td style=\"color:var(--green);font-weight:700\">\u7ea629,570\u5143\ud83d\udca1<\/td>\n                        <\/tr>\n                    <\/table>\n                    <div class=\"note ng\" style=\"margin-top:10px;font-size:12px\">\n                        <strong>\u5b63\u8d39\u7528\uff1a<\/strong>\n                        \u7ea63,000-3,600\u5143\/\u5b63\uff08\u6bd4\u65b9\u6848A\u7701800-900\u5143\uff09\n                        <br>\n                        <strong>20\u5e74\u603b\u6295\u5165\uff1a<\/strong>\n                        \u7ea677,720\u5143\uff08\u6700\u7701\uff09\n                                \n                    <\/div>\n                <\/div>\n\n                <!-- \u65b9\u6848A -->\n                <div class=\"plan-card\">\n                    <div class=\"plan-badge\" style=\"background:var(--blue)\">\u5907\u9009\u65b9\u6848<\/div>\n                    <div class=\"plan-name\" style=\"color:var(--blue)\">\u65b9\u6848 A<\/div>\n                    <div style=\"font-size:13px;color:var(--text-light);margin-bottom:8px\">\u535a\u4e16\u51b7\u51dd3260W 25kW + 32+20\u8282\u80fd\u7ba1\u8def<\/div>\n                    <div class=\"plan-price\" style=\"color:var(--blue)\">\n                        \u00a528,309 \n                        <small>\u51cf\u56fd\u8865\u00a51,436\u540e<\/small>\n                    <\/div>\n                    <div>\n                        <span class=\"plan-tag\" style=\"background:#e8f4fd\">\u2705 \u8282\u80fd\u7ba1\u8def<\/span>\n                        <span class=\"plan-tag\" style=\"background:#e8f4fd\">\u2705 \u5fb7\u7cfb\u54c1\u8d28<\/span>\n                        <span class=\"plan-tag\" style=\"background:#e8f4fd\">\u2705 \u667a\u80fd\u8054\u7f51<\/span>\n                    <\/div>\n                    <table class=\"tbl\" style=\"margin-top:12px\">\n                        <tr>\n                            <td>\u9505\u7089<\/td>\n                            <td>\u535a\u4e163260W 25kW<\/td>\n                            <td>9,575\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u7ba1\u8def<\/td>\n                            <td>32\u4e3b\u7ba1+20\u76d8\u7ba1<\/td>\n                            <td>\u7ea619,570\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u5b89\u88c5\u8d39<\/td>\n                            <td>\u9505\u7089\u5b89\u88c5<\/td>\n                            <td>600\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"font-weight:700\">\u5408\u8ba1\uff08\u51cf\u8865\u8d34\uff09<\/td>\n                            <td><\/td>\n                            <td style=\"font-weight:700\">\u7ea628,309\u5143\ud83d\udca1<\/td>\n                        <\/tr>\n                    <\/table>\n                    <div class=\"note nb\" style=\"margin-top:10px;font-size:12px\">\n                        <strong>\u5b63\u8d39\u7528\uff1a<\/strong>\n                        \u7ea63,000-3,600\u5143\/\u5b63\uff08\u540c\u65b9\u6848B\uff09\n                        <br>\n                        <strong>20\u5e74\u603b\u6295\u5165\uff1a<\/strong>\n                        \u7ea681,395\u5143\n                                \n                    <\/div>\n                <\/div>\n\n                <!-- \u65b9\u6848C\uff08\u4e0d\u63a8\u8350\uff09 -->\n                <div class=\"plan-card\" style=\"border-color:#ffcdd2;opacity:.85\">\n                    <div class=\"plan-badge warn\">\u26a0\ufe0f \u4e0d\u63a8\u8350<\/div>\n                    <div class=\"plan-name\" style=\"color:var(--red)\">\u65b9\u6848 C<\/div>\n                    <div style=\"font-size:13px;color:var(--text-light);margin-bottom:8px\">\u66fc\u745e\u5fb7\u5361\u8bfa 24kW + 25+16\u5e02\u573a\u901a\u914d\u7ba1\u8def<\/div>\n                    <div class=\"plan-price\" style=\"color:var(--red)\">\n                        \u00a523,780 \n                        <small>\u51cf\u56fd\u8865\u00a51,500\u540e<\/small>\n                    <\/div>\n                    <div>\n                        <span class=\"plan-tag\" style=\"background:#fdecea;color:var(--red)\">\u274c \u7ba1\u8def\u74f6\u9888<\/span>\n                        <span class=\"plan-tag\" style=\"background:#fdecea;color:var(--red)\">\u274c \u9891\u7e41\u542f\u505c<\/span>\n                    <\/div>\n                    <table class=\"tbl\" style=\"margin-top:12px\">\n                        <tr>\n                            <td>\u9505\u7089<\/td>\n                            <td>\u66fc\u745e\u5fb7\u5361\u8bfa24kW<\/td>\n                            <td>10,900\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u7ba1\u8def<\/td>\n                            <td>25\u4e3b\u7ba1+16\u76d8\u7ba1<\/td>\n                            <td class=\"bad\">\u7ea613,780\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u5b89\u88c5\u8d39<\/td>\n                            <td>\u9505\u7089\u5b89\u88c5<\/td>\n                            <td>600\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"font-weight:700\">\u5408\u8ba1\uff08\u51cf\u8865\u8d34\uff09<\/td>\n                            <td><\/td>\n                            <td class=\"bad\">\u7ea623,780\u5143<\/td>\n                        <\/tr>\n                    <\/table>\n                    <div class=\"note nr\" style=\"margin-top:10px;font-size:12px\">\n                        <strong>\u5b63\u8d39\u7528\uff1a<\/strong>\n                        \u7ea63,800-4,500\u5143\uff08\u6bd4\u65b9\u6848B\u591a800-900\u5143\/\u5e74\uff09\n                        <br>\n                        <strong>\u95ee\u9898\uff1a<\/strong>\n                        De25\u7ba1\u8def\u662f\u74f6\u9888\uff0c\u5bfc\u81f4\u9505\u7089\u9891\u7e41\u542f\u505c\uff0c\u8d39\u94b1\u6548\u679c\u8fd8\u5dee\n                                \n                    <\/div>\n                <\/div>\n            <\/div>\n\n            <!-- 3.4 \u65b9\u6848\u5bf9\u6bd4\u8868 -->\n            <div class=\"card edge-b\" style=\"margin-bottom:16px\">\n                <h3>\ud83d\udcca \u4e09\u65b9\u6848\u5168\u7ef4\u5ea6\u5bf9\u6bd4\u8868<\/h3>\n                <div style=\"overflow-x:auto\">\n                    <table class=\"tbl\">\n                        <thead>\n                            <tr>\n                                <th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n                                <th>\u65b9\u6848A \u00b7 \u535a\u4e16+32+20<\/th>\n                                <th class=\"hi\">\u65b9\u6848B \u00b7 \u66fc\u745e\u5fb7+32+20 \ud83d\udd25\u63a8\u8350<\/th>\n                                <th class=\"bad\">\u65b9\u6848C \u00b7 \u66fc\u745e\u5fb7+25+16 \u274c<\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr>\n                                <td>\u521d\u6295\u8d44\uff08\u51cf\u56fd\u8865\uff09<\/td>\n                                <td>\u7ea628,309\u5143<\/td>\n                                <td class=\"hi\">\u7ea629,570\u5143\uff08\u8d351,261\u5143\uff09<\/td>\n                                <td>\u7ea623,780\u5143<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u9505\u7089\u6700\u5c0f\u8f93\u51fa<\/td>\n                                <td>5-7kW<\/td>\n                                <td class=\"hi\">4kW\uff08\u5b8c\u7f8e\u5339\u914d\uff09<\/td>\n                                <td>4kW<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u7ba1\u8def\u70ed\u4f20\u8f93\u80fd\u529b<\/td>\n                                <td class=\"hi\">11.6kW\uff08\u5145\u8db3\uff09<\/td>\n                                <td class=\"hi\">11.6kW\uff08\u5145\u8db3\uff09<\/td>\n                                <td class=\"bad\">5.8kW\uff08\u4e34\u754c\uff09<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u9505\u7089\u8fd0\u884c\u72b6\u6001<\/td>\n                                <td>\u5e73\u7a33\u504f\u9891\u542f\u505c<\/td>\n                                <td class=\"hi\">\u6700\u5e73\u7a33<\/td>\n                                <td class=\"bad\">\u9891\u7e41\u542f\u505c<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u5b63\u8d39\u7528<\/td>\n                                <td>3,000-3,600\u5143<\/td>\n                                <td class=\"hi\">3,000-3,600\u5143\uff08\u6700\u7701\uff09<\/td>\n                                <td class=\"bad\">3,800-4,500\u5143<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u70ed\u6c34\u4ea7\u7387<\/td>\n                                <td>14.3L\/min<\/td>\n                                <td class=\"hi\">15.5L\/min\uff08\u591a1.2\u5347\uff09<\/td>\n                                <td class=\"hi\">15.5L\/min<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u70ed\u6548\u7387<\/td>\n                                <td>103-105%<\/td>\n                                <td class=\"hi\">108%\uff08\u6700\u9ad8\uff09<\/td>\n                                <td class=\"hi\">108%<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>10\u5e74\u603b\u6295\u5165<\/td>\n                                <td>\u7ea648,395\u5143<\/td>\n                                <td class=\"hi\">\u7ea647,220\u5143\uff08\u6700\u7701\uff09<\/td>\n                                <td>\u7ea657,080\u5143<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>20\u5e74\u603b\u6295\u5165<\/td>\n                                <td>\u7ea681,395\u5143<\/td>\n                                <td class=\"hi\">\u7ea677,720\u5143\uff08\u6700\u7701\uff09<\/td>\n                                <td>\u7ea698,280\u5143<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>\u7efc\u5408\u63a8\u8350<\/td>\n                                <td>\u5907\u9009\u00b7\u6027\u4ef7\u6bd4\u5c1a\u53ef<\/td>\n                                <td class=\"hi\">\n                                    <strong>\u5f3a\u70c8\u63a8\u8350<\/strong>\n                                <\/td>\n                                <td class=\"bad\">\u4e0d\u63a8\u8350<\/td>\n                            <\/tr>\n                        <\/tbody>\n                    <\/table>\n                <\/div>\n            <\/div>\n\n            <!-- 3.5 \u6210\u672c\u5206\u6790 -->\n            <div class=\"card edge-b\" style=\"margin-bottom:16px\">\n                <h3>\ud83d\udcb0 \u6210\u672c\u5206\u6790 \u00b7 20\u5e74\u5168\u5468\u671f\u603b\u8d26<\/h3>\n                <div class=\"note nb\" style=\"margin-bottom:14px\">\n                    <strong>\u6d4b\u7b97\u5de5\u51b5\uff1a<\/strong>\n                    \u6210\u90fd115.87\u33a1\u4e8c\u5c42\u6237\u578b \u00b7 \u91c7\u6696\u5b63120\u5929 \u00b7 \u5929\u7136\u6c14\u4ef7\u683c2.5\u5143\/m\u00b3 \u00b7 \u57fa\u4e8e\u5b9e\u9645\u80fd\u8017\u8d1f\u83775.8kW\u8ba1\u7b97\n                          \n                <\/div>\n                <table class=\"tbl\">\n                    <thead>\n                        <tr>\n                            <th>\u8d39\u7528\u9879\u76ee<\/th>\n                            <th>\u65b9\u6848A\uff08\u535a\u4e16+\u8282\u80fd\u7ba1\uff09<\/th>\n                            <th class=\"hi\">\u65b9\u6848B\uff08\u66fc\u745e\u5fb7+\u8282\u80fd\u7ba1\uff09\ud83d\udd25<\/th>\n                            <th>\u65b9\u6848C\uff08\u66fc\u745e\u5fb7+\u901a\u914d\u7ba1\uff09<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>\n                                <strong>\u521d\u6295\u8d44\uff08\u51cf\u8865\u8d34\uff09<\/strong>\n                            <\/td>\n                            <td>\u00a528,309<\/td>\n                            <td class=\"hi\">\u00a529,570<\/td>\n                            <td>\u00a523,780<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong>\u5e74\u5b63\u8fd0\u884c\u8d39<\/strong>\n                            <\/td>\n                            <td>3,000-3,600\u5143<\/td>\n                            <td class=\"hi\">3,000-3,600\u5143<\/td>\n                            <td class=\"bad\">3,800-4,500\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong>10\u5e74\u603b\u8fd0\u884c\u8d39<\/strong>\n                            <\/td>\n                            <td>\u7ea620,086\u5143<\/td>\n                            <td class=\"hi\">\u7ea617,650\u5143<\/td>\n                            <td>\u7ea633,300\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong>10\u5e74\u603b\u6295\u5165<\/strong>\n                            <\/td>\n                            <td>\u7ea648,395\u5143<\/td>\n                            <td class=\"hi\">\u7ea647,220\u5143<\/td>\n                            <td>\u7ea657,080\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\n                                <strong>20\u5e74\u603b\u8fd0\u884c\u8d39<\/strong>\n                            <\/td>\n                            <td>\u7ea653,086\u5143<\/td>\n                            <td class=\"hi\">\u7ea648,150\u5143<\/td>\n                            <td>\u7ea674,500\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td style=\"color:var(--orange);font-weight:700\">20\u5e74\u603b\u6295\u5165\uff08\u5408\u8ba1\uff09<\/td>\n                            <td>\u7ea681,395\u5143<\/td>\n                            <td class=\"hi\" style=\"font-size:15px\">\n                                <strong>\u7ea677,720\u5143<\/strong>\n                            <\/td>\n                            <td class=\"bad\">\u7ea698,280\u5143<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                <!-- \u5e74\u8d39\u6761\u5f62\u56fe -->\n                <div style=\"margin-top:16px\">\n                    <p style=\"font-size:13px;font-weight:700;margin-bottom:8px\">\u5e74\u5b63\u8fd0\u884c\u8d39\u53ef\u89c6\u5316\u5bf9\u6bd4\uff08\u4e2d\u503c\uff09\uff1a<\/p>\n                    <div style=\"display:flex;align-items:center;gap:8px;margin-bottom:6px\">\n                        <div style=\"width:100px;font-size:12px;color:var(--text-light)\">\u65b9\u6848B\uff08\u63a8\u8350\uff09<\/div>\n                        <div class=\"cost-bar\" style=\"width:58%;background:var(--green)\">3,300\u5143\/\u5b63<\/div>\n                    <\/div>\n                    <div style=\"display:flex;align-items:center;gap:8px;margin-bottom:6px\">\n                        <div style=\"width:100px;font-size:12px;color:var(--text-light)\">\u65b9\u6848A\uff08\u5907\u9009\uff09<\/div>\n                        <div class=\"cost-bar\" style=\"width:58%;background:var(--blue)\">3,300\u5143\/\u5b63<\/div>\n                    <\/div>\n                    <div style=\"display:flex;align-items:center;gap:8px\">\n                        <div style=\"width:100px;font-size:12px;color:var(--text-light)\">\u65b9\u6848C\uff08\u4e0d\u63a8\uff09<\/div>\n                        <div class=\"cost-bar\" style=\"width:74%;background:var(--red)\">4,150\u5143\/\u5b63\uff08\u8d35\u7ea61,700\u5143\/\u5e74\uff09<\/div>\n                    <\/div>\n                <\/div>\n            <\/div>\n\n            <!-- 3.6 \u4ef7\u683c\u6c47\u603b -->\n            <div class=\"card edge-g\">\n                <h3 style=\"color:var(--green)\">\ud83d\udccb \u4ef7\u683c\u6c47\u603b \u00b7 \u63a8\u8350\u65b9\u6848B\u8be6\u7ec6\u660e\u7ec6<\/h3>\n                <table class=\"tbl\">\n                    <thead>\n                        <tr>\n                            <th>\u9879\u76ee<\/th>\n                            <th>\u5185\u5bb9<\/th>\n                            <th>\u8d39\u7528<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td colspan=\"3\" style=\"background:#f0f4f8;font-weight:700;color:var(--blue)\">\ud83d\udd25 \u70ed\u6e90\u8bbe\u5907<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u9505\u7089<\/td>\n                            <td>\u66fc\u745e\u5fb7\u5361\u8bfa\u51b7\u51dd24kW\uff08\u5168\u9884\u6df7\u51b7\u51dd\uff0c\u72ec\u7acb\u51b7\u51dd\u5ba4+\u53cc\u91cd\u6362\u70ed\uff09<\/td>\n                            <td>10,900\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u56fd\u5bb6\u8865\u8d34<\/td>\n                            <td>\u71c3\u6c14\u58c1\u6302\u7089\u56fd\u8865\uff08\u4e00\u7ea7\u80fd\u6548\uff09<\/td>\n                            <td class=\"hi\">-1,500\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td colspan=\"3\" style=\"background:#f0f4f8;font-weight:700;color:var(--blue)\">\ud83d\udd27 \u5730\u6696\u7ba1\u8def\u7cfb\u7edf\uff08\u8282\u80fd\u5b9a\u5236\u578b\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u76d8\u7ba1<\/td>\n                            <td>\u4f1f\u661f De20\u00b7\u4e94\u5c42EVOH\u963b\u6c27\u7ba1\uff085m\/\u33a1\u00d7115.87\u33a1\uff09<\/td>\n                            <td rowspan=\"5\" style=\"vertical-align:middle;font-size:14px;font-weight:700;color:var(--orange)\">\u7ea619,570\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u4e3b\u7ba1<\/td>\n                            <td>De32\u4e3b\u7ba1+\u914d\u4ef6\uff08\u6700\u5927\u6d41\u91cf1,000L\/h\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u4fdd\u6e29\u5c42<\/td>\n                            <td>\u4f1f\u661f\u767d\u6676\u677f3cm\uff08\u6297\u538b\u2265150kPa\u00b7\u4f7f\u7528\u5bff\u547d50\u5e74\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u56de\u586b\u5c42<\/td>\n                            <td>\u7c73\u77f3\uff08\u5929\u7136\u8c46\u77f3\u00b7\u5bfc\u70ed\u5747\u5300\u00b7\u4fdd\u62a4\u76d8\u7ba1\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u63a7\u5236\u7cfb\u7edf<\/td>\n                            <td>\u5206\u96c6\u6c34\u5668+\u7535\u5b50\u6267\u884c\u5668+WiFi\u7ebf\u63a7\u5668\uff08\u5206\u5ba4\u63a7\u6e29\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td colspan=\"3\" style=\"background:#f0f4f8;font-weight:700;color:var(--blue)\">\ud83d\udc77 \u5b89\u88c5\u670d\u52a1<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u5b89\u88c5\u8d39<\/td>\n                            <td>\u9505\u7089\u5b89\u88c5<\/td>\n                            <td>600\u5143<\/td>\n                        <\/tr>\n                        <tr>\n                            <td colspan=\"3\" style=\"background:#f0f4f8;font-weight:700;color:var(--blue)\">\u5408\u8ba1<\/td>\n                        <\/tr>\n                        <tr style=\"background:#e8f8ee;font-weight:700\">\n                            <td colspan=\"2\">\u539f\u4ef7\u5408\u8ba1<\/td>\n                            <td>31,070\u5143<\/td>\n                        <\/tr>\n                        <tr style=\"background:#e8f8ee;font-weight:700\">\n                            <td colspan=\"2\">\u51cf\u56fd\u5bb6\u8865\u8d341,500\u5143<\/td>\n                            <td style=\"color:var(--green);font-size:15px\">\ud83d\udca1 \u7ea629,570\u5143<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n        <\/div>\n    <\/div>\n\n    <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n         \u7b2c\u56db\u6b65\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c\n    \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n    <div class=\"step-section\" id=\"step4\" style=\"background:#f0fff4\">\n        <div class=\"wrap\">\n            <div class=\"step-header\">\n                <div class=\"step-num c4\">\u2463<\/div>\n                <div>\n                    <div class=\"step-title\" style=\"color:var(--green)\">\u65bd\u5de5\u4ea4\u4ed8 \u00b7 \u670d\u52a1\u4fdd\u969c<\/div>\n                    <div class=\"step-desc\">\u600e\u4e48\u65bd\u5de5 \u00b7 \u600e\u4e48\u9a8c\u6536 \u00b7 \u600e\u4e48\u4ea4\u4ed8 \u00b7 10\u5e74\u8282\u80fd\u6863\u6848<\/div>\n                <\/div>\n            <\/div>\n\n            <!-- \u65bd\u5de5\u6d41\u7a0b -->\n            <div class=\"card edge-g\" style=\"margin-bottom:16px\">\n                <h3>\ud83d\udd27 \u65bd\u5de5\u6d41\u7a0b \u00b7 6\u6b65\u6807\u51c6\u5316\u4f5c\u4e1a<\/h3>\n                <div class=\"flow-steps\">\n                    <div class=\"flow-item\">\n                        <div class=\"flow-dot\">1<\/div>\n                        <div class=\"flow-content\">\n                            <h4>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h4>\n                            <p>\u6d4b\u91cf\u5404\u623f\u95f4\u7cbe\u786e\u9762\u79ef \u00b7 \u786e\u8ba4\u697c\u677f\u7ed3\u6784 \u00b7 \u5236\u5b9a\u7ba1\u8def\u56de\u8def\u65b9\u6848 \u00b7 \u8f93\u51fa\u65bd\u5de5\u56fe\u7eb8<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"flow-item\">\n                        <div class=\"flow-dot\">2<\/div>\n                        <div class=\"flow-content\">\n                            <h4>\u4e00\u671f\u9690\u853d\u5de5\u7a0b<\/h4>\n                            <p>\u94fa\u8bbe\u4fdd\u6e29\u5c42\uff08\u4f1f\u661f\u767d\u6676\u677f3cm\uff09\u2192 \u5e03\u76d8\u7ba1\uff08De20\u00b7\u6309\u56fe\u65bd\u5de5\uff09\u2192 \u6253\u538b\u6d4b\u8bd5\uff080.6MPa\u4fdd\u538b24h\uff09\u2192 \u7c73\u77f3\u56de\u586b \u2192 \u76d1\u7406\u9a8c\u6536\u62cd\u7167\u5b58\u6863<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"flow-item\">\n                        <div class=\"flow-dot\">3<\/div>\n                        <div class=\"flow-content\">\n                            <h4>\u4e3b\u7ba1\u5b89\u88c5\u4e0e\u8054\u8c03<\/h4>\n                            <p>De32\u4e3b\u7ba1\u5b89\u88c5 \u2192 \u5206\u96c6\u6c34\u5668\u5b9a\u4f4d \u2192 \u5404\u56de\u8def\u8fde\u63a5 \u2192 \u7cfb\u7edf\u6ce8\u6c34\u6392\u6c14 \u2192 \u521d\u6b21\u542f\u52a8\u8c03\u8bd5<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"flow-item\">\n                        <div class=\"flow-dot\">4<\/div>\n                        <div class=\"flow-content\">\n                            <h4>\u9505\u7089\u5b89\u88c5\u4e0e\u8054\u52a8<\/h4>\n                            <p>\u66fc\u745e\u5fb7\u5361\u8bfa24kW\u9505\u7089\u6302\u88c5 \u2192 \u71c3\u6c14\u7ba1\u9053\u8fde\u63a5 \u2192 \u7535\u6c14\u63a5\u7ebf \u2192 \u81a8\u80c0\u6c34\u7bb1\u5b89\u88c5 \u2192 \u9996\u6b21\u70b9\u706b\u8c03\u8bd5<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"flow-item\">\n                        <div class=\"flow-dot\">5<\/div>\n                        <div class=\"flow-content\">\n                            <h4>\u7cfb\u7edf\u9a8c\u6536\u4e0e\u4ea4\u4ed8<\/h4>\n                            <p>\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c\u6d4b\u8bd5 \u2192 \u5404\u623f\u95f4\u5747\u6e29\u9a8c\u8bc1 \u2192 \u70ed\u6c34\u4ea7\u7387\u6d4b\u8bd5 \u2192 \u51fa\u5177\u9a8c\u6536\u62a5\u544a \u2192 \u64cd\u4f5c\u57f9\u8bad \u2192 \u4ea4\u4ed8\u8d44\u6599\u5305<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"flow-item\">\n                        <div class=\"flow-dot\">6<\/div>\n                        <div class=\"flow-content\">\n                            <h4>\u9996\u6b21\u91c7\u6696\u5b63\u8ddf\u8e2a<\/h4>\n                            <p>\u91c7\u6696\u5b63\u5f00\u59cb\u524d\u514d\u8d39\u4e0a\u95e8\u68c0\u67e5 \u2192 \u7cfb\u7edf\u53c2\u6570\u4f18\u5316 \u2192 \u5efa\u7acb\u80fd\u8017\u6863\u6848 \u2192 \u51fa\u5177\u7b2c\u4e00\u4efd\u80fd\u8017\u5206\u6790\u62a5\u544a<\/p>\n                        <\/div>\n                    <\/div>\n                <\/div>\n            <\/div>\n\n            <!-- \u9a8c\u6536\u6807\u51c6 -->\n            <div class=\"grid-2\" style=\"margin-bottom:16px\">\n                <div class=\"card edge-g\">\n                    <h3>\u2705 \u9a8c\u6536\u6807\u51c6\uff08\u56db\u9879\u5fc5\u8fbe\uff09<\/h3>\n                    <ul style=\"font-size:13px;line-height:2.2;padding-left:20px;\">\n                        <li>\n                            <strong>\u6253\u538b\u6d4b\u8bd5\uff1a<\/strong>\n                            0.6MPa\u4fdd\u538b24\u5c0f\u65f6\uff0c\u538b\u964d\u22640.02MPa\n                        <\/li>\n                        <li>\n                            <strong>\u5747\u6e29\u9a8c\u8bc1\uff1a<\/strong>\n                            \u5404\u623f\u95f4\u5730\u8868\u6e29\u5ea6\u5dee\u2264\u00b12\u2103\n                        <\/li>\n                        <li>\n                            <strong>\u70ed\u6c34\u6d4b\u8bd5\uff1a<\/strong>\n                            \u70ed\u6c34\u51fa\u6c34\u65f6\u95f4\u226415\u79d2\n                        <\/li>\n                        <li>\n                            <strong>\u566a\u97f3\u68c0\u6d4b\uff1a<\/strong>\n                            \u9505\u7089\u8fd0\u884c\u566a\u97f3\u226445dB\n                        <\/li>\n                    <\/ul>\n                <\/div>\n                <div class=\"card edge-g\">\n                    <h3>\ud83d\udce6 \u4ea4\u4ed8\u8d44\u6599\u5305\uff085\u4efd\u6587\u4ef6\uff09<\/h3>\n                    <ul style=\"font-size:13px;line-height:2.2;padding-left:20px;\">\n                        <li>\u65bd\u5de5\u7ae3\u5de5\u56fe\uff08\u7cbe\u786e\u7ba1\u8def\u8d70\u5411\uff09<\/li>\n                        <li>\u6253\u538b\u6d4b\u8bd5\u62a5\u544a\uff08\u5e26\u76d1\u7406\u7b7e\u5b57\uff09<\/li>\n                        <li>\u8bbe\u5907\u8d28\u4fdd\u8bc1\u4e66\uff08\u9505\u7089+\u7ba1\u6750\uff09<\/li>\n                        <li>\u64cd\u4f5c\u8bf4\u660e\u4e66\uff08\u4e2d\u6587\u7248\uff09<\/li>\n                        <li>10\u5e74\u80fd\u8017\u6863\u6848\u7b2c\u4e00\u9875\uff08\u521d\u59cb\u6570\u636e\uff09<\/li>\n                    <\/ul>\n                <\/div>\n            <\/div>\n\n            <!-- 10\u5e74\u8282\u80fd\u6863\u6848 -->\n            <div class=\"card edge-gold\">\n                <h3 style=\"color:var(--gold)\">\ud83d\udcca 10\u5e74\u8282\u80fd\u6863\u6848 \u00b7 \u80fd\u8017\u8ddf\u8e2a\u627f\u8bfa<\/h3>\n                <div class=\"note ngold\" style=\"margin-bottom:14px\">\n                    <strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong>\n                    \u6211\u4eec\u627f\u8bfa10\u5e74\u6301\u7eed\u8ddf\u8e2a\u60a8\u7684\u7cfb\u7edf\u80fd\u8017\uff0c\u6bcf\u5e74\u51fa\u5177\u4e00\u4efd\u80fd\u8017\u5206\u6790\u62a5\u544a\uff0c\u5e2e\u60a8\u9a8c\u8bc1\u7cfb\u7edf\u6548\u7387\u662f\u5426\u8fbe\u6807\uff0c\u53ca\u65f6\u53d1\u73b0\u6f5c\u5728\u95ee\u9898\u3002\n                          \n                <\/div>\n                <table class=\"tbl\">\n                    <thead>\n                        <tr>\n                            <th>\u65f6\u95f4\u8282\u70b9<\/th>\n                            <th>\u670d\u52a1\u5185\u5bb9<\/th>\n                            <th>\u4ea4\u4ed8\u6210\u679c<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>\u7b2c1\u5e74\uff08\u4ea4\u4ed8\uff09<\/td>\n                            <td>\u5efa\u7acb\u80fd\u8017\u57fa\u51c6\u6863\u6848\uff0c\u8bb0\u5f55\u521d\u59cb\u53c2\u6570<\/td>\n                            <td>\u521d\u59cb\u80fd\u8017\u62a5\u544a<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u6bcf\u5e74\u91c7\u6696\u5b63\u524d<\/td>\n                            <td>\u514d\u8d39\u4e0a\u95e8\u4fdd\u517b\u00b7\u53c2\u6570\u8c03\u4f18\u00b7\u6ee4\u7f51\u6e05\u6d17<\/td>\n                            <td>\u4fdd\u517b\u8bb0\u5f55\u5355<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u6bcf\u5e74\u91c7\u6696\u5b63\u540e<\/td>\n                            <td>\u51fa\u5177\u5e74\u5ea6\u80fd\u8017\u5206\u6790\u62a5\u544a\uff0c\u5bf9\u6bd4\u57fa\u51c6\u6570\u636e<\/td>\n                            <td>\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u7b2c3\u5e74<\/td>\n                            <td>\u7cfb\u7edf\u5168\u9762\u68c0\u67e5\uff0c\u8bc4\u4f30\u7ba1\u8def\u5bc6\u5c01\u6027<\/td>\n                            <td>\u4e2d\u671f\u68c0\u67e5\u62a5\u544a<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u7b2c5\u5e74<\/td>\n                            <td>\u8d28\u4fdd\u6838\u67e5 + \u91cd\u8981\u90e8\u4ef6\u68c0\u6d4b + \u6548\u7387\u8bc4\u4f30<\/td>\n                            <td>5\u5e74\u8d28\u4fdd\u62a5\u544a<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u7b2c10\u5e74<\/td>\n                            <td>10\u5e74\u80fd\u8017\u603b\u7ed3 + \u7cfb\u7edf\u5065\u5eb7\u8bc4\u4f30 + \u7eed\u4fdd\u5efa\u8bae<\/td>\n                            <td>10\u5e74\u6863\u6848\u6c47\u603b<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n            <!-- \u670d\u52a1\u627f\u8bfa -->\n            <div class=\"card edge-g\" style=\"margin-top:16px\">\n                <h3 style=\"color:var(--green)\">\ud83d\udee1\ufe0f \u4e5d\u9879\u670d\u52a1\u627f\u8bfa<\/h3>\n                <div class=\"grid-3\" style=\"margin-top:12px\">\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83d\udd0d<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u7cbe\u51c6\u6d4b\u91cf\uff0c\u4e13\u4e1a\u65b9\u6848<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\u23f1\ufe0f<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">48\u5c0f\u65f6\u5185\u54cd\u5e94<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u552e\u540e\u95ee\u9898\u53ca\u65f6\u5904\u7406<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83d\udccb<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">\u591a\u65b9\u6848\u5bf9\u6bd4<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u22652\u5957\u8bbe\u8ba1\u65b9\u6848\u4f9b\u9009<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\u2692\ufe0f<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">\u89c4\u8303\u65bd\u5de5\u6807\u51c6<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u7cbe\u5de5\u7cbe\u5320\uff0c\u6309\u56fe\u65bd\u5de5<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83d\udc8e<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">\u900f\u660e\u62a5\u4ef7<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u65e0\u9690\u85cf\u589e\u9879\uff0c\u660e\u7801\u6807\u4ef7<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83d\udd12<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">5\u5e74\u65bd\u5de5\u8d28\u4fdd<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u8fdc\u8d85\u884c\u4e1a\u6807\u51c62\u5e74<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83d\udcca<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83d\udcf1<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">APP\u8fdc\u7a0b\u76d1\u63a7<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u968f\u65f6\u67e5\u770b\u7cfb\u7edf\u72b6\u6001<\/div>\n                    <\/div>\n                    <div style=\"text-align:center;padding:12px;background:#f0fff4;border-radius:8px\">\n                        <div style=\"font-size:20px;margin-bottom:4px\">\ud83e\udd1d<\/div>\n                        <div style=\"font-size:13px;font-weight:700\">\u7ec8\u8eab\u6280\u672f\u652f\u6301<\/div>\n                        <div style=\"font-size:12px;color:var(--text-light)\">\u6709\u95ee\u9898\u968f\u65f6\u8054\u7cfb<\/div>\n                    <\/div>\n                <\/div>\n            <\/div>\n\n        <\/div>\n    <\/div>\n\n    <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n         \u7b2c\u4e94\u6b65\uff1a\u9a8c\u8bc1\u4e0e\u8fed\u4ee3\n    \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n    <div class=\"step-section\" id=\"step5\" style=\"background:#fffbf0\">\n        <div class=\"wrap\">\n            <div class=\"step-header\">\n                <div class=\"step-num c5\">\u2464<\/div>\n                <div>\n                    <div class=\"step-title\" style=\"color:var(--gold)\">\u9a8c\u8bc1\u4e0e\u8fed\u4ee3 \u00b7 \u6848\u4f8b\u00b7\u590d\u76d8\u00b7\u53ef\u4f20\u627f\u7ecf\u9a8c<\/div>\n                    <div class=\"step-desc\">\u6210\u529f\u6848\u4f8b\u9a8c\u8bc1 \u00b7 \u5931\u8d25\u6848\u4f8b\u590d\u76d8 \u00b7 \u53ef\u4f20\u627f\u7684\u7ecf\u9a8c\u603b\u7ed3<\/div>\n                <\/div>\n            <\/div>\n\n            <!-- \u6210\u529f\u6848\u4f8b -->\n            <h3 style=\"font-size:16px;font-weight:700;margin-bottom:14px;color:var(--gold)\">5.1 \u6210\u529f\u6848\u4f8b\u9a8c\u8bc1<\/h3>\n            <div class=\"grid-3\" style=\"margin-bottom:20px\">\n                <div class=\"case-card\">\n                    <div class=\"case-tag\">115\u33a1 \u00b7 \u76f8\u4f3c\u6848\u4f8b<\/div>\n                    <div style=\"font-size:14px;font-weight:700;margin-bottom:6px\">\u5f20\u5148\u751f \u00b7 \u6e29\u6c5f\u67d0\u5c0f\u533a<\/div>\n                    <p style=\"font-size:13px;color:var(--text-light);line-height:1.8;margin-bottom:8px\">\n\n                                  \u540c\u6837115\u33a1\u4e24\u5c42\u6237\u578b\uff0c\u80fd\u8017\u8d1f\u83775.9kW\uff0c\u9009\u7528\u66fc\u745e\u5fb724kW+32\u4e3b\u7ba1+20\u76d8\u7ba1\u65b9\u6848\u3002\n                                  \u7b2c\u4e00\u4e2a\u91c7\u6696\u5b63\u5b9e\u6d4b\u5b63\u8d39\u7528\n                        <strong style=\"color:var(--green)\">3,150\u5143<\/strong>\n                        \uff0c\u8fdc\u4f18\u4e8e\u5bf9\u6bd4\u65b9\u6848\uff08\u4f30\u7b973,900\u5143\uff09\u3002\n                                  \u5168\u5c4b\u6e29\u5dee\u22641.5\u2103\uff0c\u70ed\u6c34\u51fa\u6c34\u226410\u79d2\u3002\n                                \n                    <\/p>\n                    <div class=\"case-star\">\u2605\u2605\u2605\u2605\u2605<\/div>\n                    <p style=\"font-size:12px;color:var(--text-light)\">\u300c\u5f3a\u70c8\u63a8\u8350\uff0c\u6548\u679c\u8d85\u51fa\u9884\u671f\uff0c\u4f59\u7ecf\u7406\u670d\u52a1\u5f88\u5230\u4f4d\u300d<\/p>\n                <\/div>\n                <div class=\"case-card\">\n                    <div class=\"case-tag\">\u51b7\u51dd\u7089+\u8282\u80fd\u7ba1 \u00b7 \u9a8c\u8bc1<\/div>\n                    <div style=\"font-size:14px;font-weight:700;margin-bottom:6px\">\u9648\u5973\u58eb \u00b7 \u9ad8\u65b0\u533a\u67d0\u697c\u76d8<\/div>\n                    <p style=\"font-size:13px;color:var(--text-light);line-height:1.8;margin-bottom:8px\">\n\n                                  105\u33a1\u5e73\u5c42\uff0c\u539f\u610f\u9009\u535a\u4e16G6100W\u666e\u901a\u7089+25+16\u7ba1\u8def\u3002\u9f99\u8109\u987e\u95ee\u5efa\u8bae\u5347\u7ea7\u4e3a\u51b7\u51dd\u7089+32+20\u8282\u80fd\u7ba1\u8def\u3002\n                                  \u5347\u7ea7\u540e\u4e09\u5e74\u5bf9\u6bd4\uff1a\n                        <strong style=\"color:var(--green)\">\u7d2f\u8ba1\u7701\u71c3\u6c14\u8d39\u7ea63,600\u5143<\/strong>\n                        \uff0c\u5347\u7ea7\u8d39\u7528\u5df2\u5b8c\u5168\u6536\u56de\u3002\n                                \n                    <\/p>\n                    <div class=\"case-star\">\u2605\u2605\u2605\u2605\u2605<\/div>\n                    <p style=\"font-size:12px;color:var(--text-light)\">\u300c\u5f53\u521d\u542c\u4e86\u5efa\u8bae\u9009\u8282\u80fd\u65b9\u6848\uff0c\u73b0\u5728\u6bcf\u5e74\u90fd\u5728\u7701\u94b1\u300d<\/p>\n                <\/div>\n                <div class=\"case-card\">\n                    <div class=\"case-tag\">\u4e8c\u5c42\u6237\u578b \u00b7 \u4e13\u5c5e\u4f18\u5316<\/div>\n                    <div style=\"font-size:14px;font-weight:700;margin-bottom:6px\">\u738b\u603b \u00b7 \u53cc\u6d41\u67d0\u522b\u5885<\/div>\n                    <p style=\"font-size:13px;color:var(--text-light);line-height:1.8;margin-bottom:8px\">\n                              \u4e8c\u5c42\u6237\u578b120\u33a1\uff0c\u8d1f\u4e00\u5c42+\u4e00\u5c42+\u4e8c\u5c42\u5404\u6709\u4e0d\u540c\u70ed\u635f\u7279\u70b9\u3002\u9f99\u8109\u9488\u5bf9\u6027\u8bbe\u8ba1\u5404\u5c42\u72ec\u7acb\u56de\u8def\uff0c\u5206\u5ba4\u63a7\u6e29\u3002\n                              \u8d1f\u4e00\u5c42\uff08\u5730\u4e0b\u7a7a\u95f4\uff09\u4fdd\u6e29\u5c42\u52a0\u539a\u81f35cm\uff0c\u5b9e\u6d4b\u6696\u548c\u8212\u9002\uff0c\u65e0\u300c\u811a\u51c9\u300d\u95ee\u9898\u3002\n                            <\/p>\n                    <div class=\"case-star\">\u2605\u2605\u2605\u2605\u2605<\/div>\n                    <p style=\"font-size:12px;color:var(--text-light)\">\u300c\u4e8c\u5c42\u6237\u578b\u7279\u522b\u5bb9\u6613\u6709\u51b7\u70ed\u4e0d\u5747\uff0c\u8fd9\u6b21\u5f7b\u5e95\u89e3\u51b3\u4e86\u300d<\/p>\n                <\/div>\n            <\/div>\n\n            <!-- \u5931\u8d25\u6848\u4f8b\u590d\u76d8 -->\n            <h3 style=\"font-size:16px;font-weight:700;margin-bottom:14px;color:var(--red)\">5.2 \u5931\u8d25\u6848\u4f8b\u590d\u76d8\uff08\u5f15\u4ee5\u4e3a\u6212\uff09<\/h3>\n            <div class=\"grid-2\" style=\"margin-bottom:20px\">\n                <div class=\"card edge-r\">\n                    <h3 style=\"color:var(--red)\">\u274c \u6848\u4f8b\uff1a\u56fe\u4fbf\u5b9c\u900925+16\u7ba1\u8def<\/h3>\n                    <p style=\"font-size:13px;line-height:1.8;color:var(--text-light);margin-bottom:8px\">\n                              \u6210\u90fd\u67d0\u5c0f\u533a\u674e\u5148\u751f\uff0c120\u33a1\uff0c\u4e3a\u77013,000\u5143\u521d\u6295\u8d44\u9009\u62e9\u4e8625\u4e3b\u7ba1+16\u76d8\u7ba1\u3002\n                            <\/p>\n                    <div class=\"note nr\">\n                        <strong>\u7ed3\u679c\uff1a<\/strong>\n                        \u7b2c\u4e00\u4e2a\u51ac\u5929\u53d1\u73b0\u8fdc\u7aef\u623f\u95f4\u4e0d\u70ed\uff0c\u9505\u7089\u9891\u7e41\u542f\u505c\uff0c\u5b9e\u6d4b\u5b63\u8d39\u75284,300\u5143\uff0c\u6bd4\u9884\u7b97\u9ad81,000+\u5143\u3002\n                        <br>\n                        <strong>\u6839\u672c\u539f\u56e0\uff1a<\/strong>\n                        De25\u7ba1\u8def\u6d41\u91cf\u4e0d\u8db3\uff0c\u70ed\u91cf\u9001\u4e0d\u51fa\u53bb\uff0c\u9505\u7089\u5f92\u52b3\u542f\u505c\u3002\n                        <br>\n                        <strong>\u540e\u7eed\u4ee3\u4ef7\uff1a<\/strong>\n                        \u5730\u677f\u5df2\u88c5\u597d\uff0c\u7ba1\u8def\u65e0\u6cd5\u66f4\u6362\uff0c\u53ea\u80fd\u6bcf\u5e74\u591a\u82b11,000\u5143\u71c3\u6c14\u8d39\uff0c20\u5e74\u989d\u5916\u652f\u51fa2\u4e07\u5143\u3002\n                                \n                    <\/div>\n                    <p style=\"font-size:12px;color:var(--red);margin-top:8px;font-weight:700\">\ud83d\udca1 \u6559\u8bad\uff1a\u7ba1\u9053\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u88c5\u5b8c\u4e0d\u53ef\u66f4\u6539\u3002\u521d\u6295\u8d44\u5dee3,000\u5143\uff0c20\u5e74\u591a\u82b12\u4e07\u5143\u3002<\/p>\n                <\/div>\n                <div class=\"card edge-r\">\n                    <h3 style=\"color:var(--red)\">\u274c \u6848\u4f8b\uff1a\u9505\u7089\u9009\u578b\u4e0d\u5339\u914d<\/h3>\n                    <p style=\"font-size:13px;line-height:1.8;color:var(--text-light);margin-bottom:8px\">\n                              \u6210\u90fd\u67d0\u522b\u5885\u533a\u8d75\u5148\u751f\uff0c100\u33a1\uff0c\u9009\u4e86\u6700\u5c0f\u8f93\u51fa8kW\u7684\u666e\u901a\u7089\uff0c\u80fd\u8017\u8d1f\u8377\u53ea\u67095kW\u3002\n                            <\/p>\n                    <div class=\"note nr\">\n                        <strong>\u7ed3\u679c\uff1a<\/strong>\n                        \u9505\u7089\u6700\u5c0f\u8f93\u51fa(8kW) > \u65e5\u5e38\u9700\u6c42(5kW)\uff0c\u9505\u7089\u9ad8\u9891\u542f\u505c\u3002\u7b2c\u4e00\u5e74\u5f02\u5e38\u8017\u6c14\uff0c\u5b63\u8d39\u7528\u9ad8\u8fbe4,800\u5143\u3002\n                        <br>\n                        <strong>\u6839\u672c\u539f\u56e0\uff1a<\/strong>\n                        \u9505\u7089\u6700\u5c0f\u8f93\u51fa\u8fdc\u5927\u4e8e\u5b9e\u9645\u9700\u6c42\uff0c\u65e0\u6cd5\u4f4e\u8d1f\u8377\u7a33\u5b9a\u8fd0\u884c\u3002\n                        <br>\n                        <strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\n                        \u66f4\u6362\u4e3a\u66fc\u745e\u5fb74kW\u6700\u5c0f\u8f93\u51fa\u7089\uff0c\u5b63\u8d39\u7528\u964d\u81f33,200\u5143\uff0c\u5e74\u77011,600\u5143\u3002\n                                \n                    <\/div>\n                    <p style=\"font-size:12px;color:var(--red);margin-top:8px;font-weight:700\">\ud83d\udca1 \u6559\u8bad\uff1a\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u5fc5\u987b\u2264\u65e5\u5e38\u80fd\u8017\u8d1f\u8377\u3002\u66fc\u745e\u5fb74kW\u662f\u60a8\u5bb6\u7684\u6700\u4f73\u5339\u914d\u3002<\/p>\n                <\/div>\n            <\/div>\n\n            <!-- \u53ef\u4f20\u627f\u7ecf\u9a8c -->\n            <h3 style=\"font-size:16px;font-weight:700;margin-bottom:14px;color:var(--gold)\">5.3 \u53ef\u4f20\u627f\u7684\u7ecf\u9a8c \u00b7 \u9f99\u810922\u5e74\u4e13\u6ce8\u603b\u7ed3<\/h3>\n            <div class=\"card edge-gold\">\n                <table class=\"tbl\">\n                    <thead>\n                        <tr>\n                            <th>#<\/th>\n                            <th>\u7ecf\u9a8c\u6cd5\u5219<\/th>\n                            <th>\u9002\u7528\u573a\u666f<\/th>\n                            <th>\u9a8c\u8bc1\u7ed3\u679c<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>\u2460<\/td>\n                            <td>\n                                <strong>\u7ba1\u8def\u70ed\u4f20\u8f93\u80fd\u529b = \u80fd\u8017\u8d1f\u8377 \u00d7 2 \u500d<\/strong>\n                            <\/td>\n                            <td>\u6240\u6709\u5730\u6696\u9879\u76ee<\/td>\n                            <td>\u5145\u8db3\u4f59\u91cf\uff0c\u9505\u7089\u4e0d\u9891\u7e41\u542f\u505c<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u2461<\/td>\n                            <td>\n                                <strong>\u9505\u7089\u6700\u5c0f\u8f93\u51fa \u2264 \u65e5\u5e38\u80fd\u8017\u8d1f\u8377<\/strong>\n                            <\/td>\n                            <td>\u6240\u6709\u5730\u6696\u9879\u76ee<\/td>\n                            <td>\u907f\u514d\u9ad8\u9891\u542f\u505c\uff0c\u7701\u71c3\u6c14\u8d3920-30%<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u2462<\/td>\n                            <td>\n                                <strong>\u4e8c\u5c42\u6237\u578b\u8d1f\u4e00\u5c42\u4fdd\u6e29\u5c42\u52a0\u539a\u81f35cm<\/strong>\n                            <\/td>\n                            <td>\u5730\u4e0b\u6216\u5e95\u5c42\u7a7a\u95f4<\/td>\n                            <td>\u89e3\u51b3\u300c\u811a\u51c9\u300d\u95ee\u9898\uff0c\u70ed\u635f\u51cf\u5c1130%<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u2463<\/td>\n                            <td>\n                                <strong>\u51b7\u51dd\u7089\u5fc5\u987b\u914d\u4f4e\u6e29\u5927\u6d41\u91cf\u7ba1\u8def\u624d\u80fd\u53d1\u6325\u6548\u7387<\/strong>\n                            <\/td>\n                            <td>\u4f7f\u7528\u51b7\u51dd\u7089\u9879\u76ee<\/td>\n                            <td>\u51b7\u51dd\u56de\u6536\u529f\u80fd\u5145\u5206\u53d1\u6325\uff0c\u70ed\u6548\u7387105%-108%<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u2464<\/td>\n                            <td>\n                                <strong>\u5206\u5ba4\u72ec\u7acb\u63a7\u6e29 = \u5e74\u770115-20% \u71c3\u6c14\u8d39<\/strong>\n                            <\/td>\n                            <td>\u591a\u623f\u95f4\u4f4f\u5b85<\/td>\n                            <td>\u4e0d\u4f4f\u4eba\u7684\u623f\u95f4\u5173\u5c0f\uff0c\u6309\u9700\u4f9b\u70ed<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>\u2465<\/td>\n                            <td>\n                                <strong>\u9996\u6b21\u91c7\u6696\u5b63\u5b9e\u6d4b \u2260 \u7406\u8bba\u4f30\u7b97\uff0c\u5fc5\u987b\u5efa\u6863\u5bf9\u6bd4<\/strong>\n                            <\/td>\n                            <td>\u6240\u6709\u9879\u76ee\u4ea4\u4ed8\u540e<\/td>\n                            <td>\u7b2c\u4e00\u5e74\u5efa\u6863\uff0c\u540e\u7eed\u6bcf\u5e74\u5bf9\u6bd4\uff0c\u53ca\u65f6\u53d1\u73b0\u5f02\u5e38<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n            <!-- \u4e00\u53e5\u8bdd\u603b\u7ed3 -->\n            <div class=\"note ngold\" style=\"margin-top:20px;padding:20px 24px\">\n                <p style=\"font-size:15px;line-height:1.9;\">\n                    <strong>\u300c\u6f58\u603b\uff0c\u60a8\u5bb6116\u33a1\u5730\u6696\uff0c\u5f3a\u70c8\u63a8\u8350\u66fc\u745e\u5fb7\u5361\u8bfa\u51b7\u51dd\u7089+32\u4e3b\u7ba1+20\u76d8\u7ba1\u65b9\u6848\u3002<\/strong>\n                    <br>\n\n                            \u521d\u6295\u8d44\u7ea629,570\u5143\uff0c\u6bd4\u535a\u4e16\u65b9\u6848\u8d351,261\u5143\uff0c\u4f46\u6bcf\u5e74\u7701800-900\u5143\u71c3\u6c14\u8d39\uff08\u9505\u7089+\u7ba1\u8def\u53cc\u91cd\u8282\u80fd\uff09\uff0c\u4e0d\u52302\u5e74\u56de\u672c\uff0c5\u5e74\u8d28\u4fdd\u515c\u5e95\uff0c20\u5e74\u603b\u77013,675\u5143\u3002\n                    <br>\n\n                            \u7ba1\u9053\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u88c5\u5b8c\u5c31\u6539\u4e0d\u4e86\u2014\u2014\u73b0\u5728\u591a\u82b1\u4e00\u70b9\uff0c\u4ee5\u540e\u7701\u5f97\u591a\u3002\u300d\n                          \n                <\/p>\n            <\/div>\n\n        <\/div>\n    <\/div>\n\n    <!-- \u2500\u2500 FOOTER \u2500\u2500 -->\n    <div class=\"footer\">\n        <div class=\"wrap\">\n            <p>\n                <strong>\u9f99\u8109\u6696\u901a<\/strong>\n                 \u00b7 \u4f59\u7231\u82f1 \n                <strong>13908183204<\/strong>\n            <\/p>\n            <p>2004\u5e74\u6210\u7acb \u00b7 22\u5e74\u4e13\u6ce8\u6210\u90fd\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf<\/p>\n            <p>\ud83d\udccd \u5357\u5bcc\u68ee2\u53f7\u5efa\u6750\u99863\u697cA3347-348<\/p>\n            <p style=\"margin-top:8px;font-size:12px;opacity:.6\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n        <\/div>\n    <\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u4f59\u7231\u82f1 | \u65b9\u6848\u524d\u4e66 \ud83d\udcf1  [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4527","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=4527\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a \u00b7 \u4f59\u7231\u82f1 | \u65b9\u6848\u524d\u4e66 \ud83d\udcf1 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=4527\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-25T10:16:12+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4527\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4527\",\"name\":\"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-25T10:16:11+00:00\",\"dateModified\":\"2026-06-25T10:16:12+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4527#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4527\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4527#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=4527","og_locale":"zh_CN","og_type":"article","og_title":"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a \u00b7 \u4f59\u7231\u82f1 | \u65b9\u6848\u524d\u4e66 \ud83d\udcf1 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=4527","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-25T10:16:12+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=4527","url":"https:\/\/longmai-nt.com\/?page_id=4527","name":"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-25T10:16:11+00:00","dateModified":"2026-06-25T10:16:12+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=4527#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=4527"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=4527#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6f58\u603b\u5730\u6696\u65b9\u6848\u524d\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4527"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4527\/revisions"}],"predecessor-version":[{"id":4528,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4527\/revisions\/4528"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}