{"id":4775,"date":"2026-06-27T16:14:18","date_gmt":"2026-06-27T08:14:18","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=4775"},"modified":"2026-07-19T15:00:57","modified_gmt":"2026-07-19T07:00:57","slug":"%e5%a4%a9%e5%ba%9c%e5%a3%b9%e5%8f%b7l%e5%a5%b3%e5%a3%ab%ef%bc%8c%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab2%e6%8b%968%e5%8a%a0%e8%b4%9f%e4%b8%80%e5%b1%82%e7%94%b5%e5%9c%b0%e6%9a%96","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=4775","title":{"rendered":"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848"},"content":{"rendered":"\n<style>\n\/* ===== \u6807\u9898\u5c42\u6b21\u611f ===== *\/\n.wp-block-heading { border-bottom: 2px solid #e63946; padding-bottom: 8px; margin-top: 40px !important; margin-bottom: 20px !important; }\n.wp-block-heading:first-child { border-bottom: none; margin-top: 0 !important; }\n\n\/* ===== \u8868\u683c\u7f8e\u5316 ===== *\/\n.wp-block-table table { width: 100%; border-collapse: collapse; margin: 20px 0; }\n.wp-block-table th { background: #1d3557; color: #fff; padding: 12px 15px; text-align: center; font-weight: bold; }\n.wp-block-table td { padding: 10px 15px; text-align: center; border-bottom: 1px solid #e0e0e0; }\n.wp-block-table tr:nth-child(even) td { background: #f8f9fa; }\n.wp-block-table tr:hover td { background: #e8f4f8; }\n\n\/* ===== \u6838\u5fc3\u4f18\u52bf\u5361\u7247 ===== *\/\n.advantage-grid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 15px; margin: 20px 0; }\n.advantage-card { background: linear-gradient(135deg, #1d3557 0%, #457b9d 100%); color: #fff; padding: 20px; border-radius: 8px; text-align: center; }\n.advantage-card strong { display: block; font-size: 16px; margin-bottom: 6px; }\n.advantage-card span { font-size: 13px; opacity: 0.9; }\n\n\/* ===== \u62a5\u4ef7\u91d1\u6846 ===== *\/\n.price-box { background: linear-gradient(135deg, #fff3cd, #ffeeba); border: 3px solid #e63946; border-radius: 12px; padding: 25px; text-align: center; margin: 20px 0; }\n.price-box .final-price { font-size: 36px; color: #e63946; font-weight: bold; }\n\n\/* ===== \u7ade\u54c1\u5bf9\u6bd4\u6807\u8bb0 ===== *\/\n.compare-win { background: #d4edda !important; color: #155724 !important; }\n.compare-loss { background: #f8d7da !important; color: #721c24 !important; }\n\n\/* ===== \u6a2a\u5e45\u6e10\u53d8 ===== *\/\n.banner-box { background: linear-gradient(135deg, #1d3557 0%, #e63946 100%); color: #fff; padding: 30px; border-radius: 10px; margin: 20px 0; text-align: center; }\n\n\/* ===== \u7167\u7247\u5360\u4f4d\u6846 ===== *\/\n.photo-placeholder { border: 2px dashed #1d3557; border-radius: 8px; padding: 30px; text-align: center; color: #1d3557; margin: 15px 0; background: #f0f8ff; }\n.photo-placeholder::before { content: \"\ud83d\udcf8 \"; font-size: 24px; display: block; margin-bottom: 8px; }\n\n\/* ===== \u76ee\u5f55\u5bfc\u822a ===== *\/\n.toc-box { background: #f1f3f5; border-radius: 8px; padding: 20px; margin: 20px 0; }\n.toc-box ol { columns: 2; column-gap: 30px; }\n.toc-box li { margin-bottom: 6px; }\n.toc-box a { color: #1d3557; text-decoration: none; }\n.toc-box a:hover { color: #e63946; text-decoration: underline; }\n\n\/* ===== \u79fb\u52a8\u7aef\u9002\u914d ===== *\/\n@media (max-width: 768px) {\n  .advantage-grid { grid-template-columns: 1fr; }\n  .toc-box ol { columns: 1; }\n}\n\n\/* ===== \u624b\u98ce\u7434\u7bad\u5934 ===== *\/\n.h2-arrow { color: #e63946; font-size: 0.8em; margin-left: 8px; cursor: pointer; }\n.accordion-panel { overflow: hidden; transition: max-height 0.3s ease; }\n.accordion-closed + * { display: none !important; }\n.accordion-closed ~ .accordion-panel { display: none !important; }\n<\/style>\n\n\n\n<h2 class=\"wp-block-heading\">\u660e\u4fe1\u5929\u5e9c\u58f9\u53f7 \u00b7 \u65e5\u7acbEX-\u8212\u4eab160\u4e8c\u62d6\u516b + \u65b0\u98ce350 + \u7535\u5730\u6696<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83c\udfe1 \u660e\u4fe1\u5929\u5e9c\u58f9\u53f7 \u00b7 \u4e09\u5c42\u8054\u6392\u522b\u5885 \u00b7 \u4e24\u53f0\u65e5\u7acbEX-\u8212\u4eab160\u4e3b\u673a\u62d68\u53f0\u5185\u673a + \u8d1f\u4e00\u697c\u65b0\u98ce\u7cfb\u7edf + \u5fb7\u56fd\u6c49\u5821\u9601\u7535\u5730\u669640\u33a1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65e5\u7acb<\/strong> EX-\u8212\u4eab160 \u4e8c\u62d6\u516b | <strong>\u65b0\u98ce<\/strong> \u5355\u5411\u6d41350 | <strong>\u6c49\u5821\u9601<\/strong> \u7535\u5730\u6696 40\u33a1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc64 \u5ba2\u6237\uff1a\u8d56\u5973\u58eb | \ud83c\udfe0 \u6237\u578b\uff1a\u8054\u6392\u522b\u5885 \u00b7 \u4e09\u5c42 | \ud83d\udc69\u200d\ud83d\udcbc \u987e\u95ee\uff1a\u90ed\u52c7\u79c0 | \ud83d\udcc5 \u5efa\u6863\uff1a2026\u5e746\u670827\u65e5<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"toc-box\">\n<strong>\ud83d\udccb \u76ee\u5f55<\/strong>\n<ol>\n<li><a href=\"#m1\">\u9879\u76ee\u6982\u51b5<\/a><\/li>\n<li><a href=\"#m2\">\u9700\u6c42\u8bca\u65ad\u4e0e\u65b9\u6848\u65b9\u5411<\/a><\/li>\n<li><a href=\"#m3\">\u65b9\u6848\u914d\u7f6e\u8be6\u60c5<\/a><\/li>\n<li><a href=\"#m4\">\u51b7\u8d1f\u8377\u6838\u7b97<\/a><\/li>\n<li><a href=\"#m5\">\u6700\u7ec8\u4f18\u60e0\u62a5\u4ef7<\/a><\/li>\n<li><a href=\"#m6\">\u7ade\u54c1\u5bf9\u6bd4\u5206\u6790<\/a><\/li>\n<li><a href=\"#m7\">\u65b9\u6848\u6838\u5fc3\u4f18\u52bf<\/a><\/li>\n<li><a href=\"#m8\">\u670d\u52a1\u627f\u8bfa<\/a><\/li>\n<li><a href=\"#m9\">\u5408\u540c\u914d\u7f6e<\/a><\/li>\n<li><a href=\"#m10\">\u73b0\u573a\u52d8\u6d4b\u5b9a\u4f4d<\/a><\/li>\n<li><a href=\"#m11\">\u8bbe\u8ba1\u56fe\u7eb8<\/a><\/li>\n<li><a href=\"#m12\">\u6309\u56fe\u65bd\u5de5<\/a><\/li>\n<li><a href=\"#m13\">\u76d1\u7406\u8bb0\u5f55<\/a><\/li>\n<li><a href=\"#m14\">\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/a><\/li>\n<li><a href=\"#m15\">\u65b9\u6848\u987e\u95ee<\/a><\/li>\n<\/ol>\n<\/div>\n\n\n\n<h2 id=\"m1\" class=\"wp-block-heading\">\u4e00\u3001\u9879\u76ee\u6982\u51b5<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u9879\u76ee<\/th><th>\u8be6\u60c5<\/th><\/tr><tr><td><strong>\u4e1a\u4e3b<\/strong><\/td><td>\u8d56\u5973\u58eb<\/td><\/tr><tr><td><strong>\u9879\u76ee\u5730\u5740<\/strong><\/td><td>\u660e\u4fe1\u5929\u5e9c\u58f9\u53f7<\/td><\/tr><tr><td><strong>\u6237\u578b\u7c7b\u578b<\/strong><\/td><td>\u4e09\u5c42\u8054\u6392\u522b\u5885<\/td><\/tr><tr><td><strong>\u8986\u76d6\u9762\u79ef<\/strong><\/td><td>\u7ea6190\u33a1\uff08\u7a7a\u8c03\u8986\u76d68\u4e2a\u533a\u57df\uff09<\/td><\/tr><tr><td><strong>\u697c\u5c42\u5206\u5e03<\/strong><\/td><td>\u8d1f\u4e00\u697c\uff08\u6311\u9ad8+\u5939\u5c42\uff09+ \u4e00\u697c + \u4e8c\u697c<\/td><\/tr><tr><td><strong>\u5e38\u4f4f\u4eba\u53e3<\/strong><\/td><td>\u5e74\u8f7b\u592b\u59bb + \u5c0f\u5b69 + \u4fdd\u59c6\u963f\u59e8\uff084\u53e3\uff09<\/td><\/tr><tr><td><strong>\u5c45\u4f4f\u6a21\u5f0f<\/strong><\/td><td>\u5bd2\u6691\u5047\u5916\u51fa\u65c5\u6e38\uff0c\u5e73\u65f6\u5728\u6210\u90fd\u65f6\u95f4\u4e0d\u5b9a<\/td><\/tr><tr><td><strong>\u88c5\u4fee\u72b6\u6001<\/strong><\/td><td>\u6b63\u5728\u89c4\u5212<\/td><\/tr><tr><td><strong>\u9700\u6c42\u7cfb\u7edf<\/strong><\/td><td>\u4e2d\u592e\u7a7a\u8c03 + \u65b0\u98ce + \u5c40\u90e8\u7535\u5730\u6696<\/td><\/tr><tr><td><strong>\u54c1\u724c\u9009\u62e9<\/strong><\/td><td>\u65e5\u7acbEX-\u8212\u4eab\u7cfb\u5217\uff08\u5ba2\u6237\u6307\u5b9a\uff09<\/td><\/tr><tr><td><strong>\u65b9\u6848\u987e\u95ee<\/strong><\/td><td>\u90ed\u52c7\u79c0\uff08\u9f99\u8109\u6696\u901a\uff09<\/td><\/tr><tr><td><strong>\u8054\u7cfb\u7535\u8bdd<\/strong><\/td><td>18100839248<\/td><\/tr><tr><td><strong>\u5efa\u6863\u65e5\u671f<\/strong><\/td><td>2026\u5e746\u670827\u65e5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"banner-box\">\n<h3 style=\"color:#fff; margin-top:0;\">\ud83c\udfe1 \u4e09\u5c42\u8054\u6392\u522b\u5885 \u00b7 \u53cc\u4e3b\u673a\u5206\u5c42\u72ec\u7acb\u63a7\u5236<\/h3>\n<p style=\"color:#fff; opacity:0.9; margin-bottom:0;\">\u4e24\u53f0\u65e5\u7acbEX-\u8212\u4eab160\u4e3b\u673a\u5206\u522b\u62d6\u5e26\u8d1f\u4e00\u5c42+\u4e00\u5c42\u548c\u4e8c\u5c42\u533a\u57df\uff0c\u5206\u5c42\u72ec\u7acb\u63a7\u5236\uff0c\u5bd2\u6691\u5047\u5916\u51fa\u8fdc\u7a0b\u5173\u505c\u4e00\u5c42\uff0c\u4e8c\u5c42\u7167\u6837\u53ef\u7528<\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udd0d \u65b9\u6848\u4eae\u70b9\uff1a<\/strong> \u8054\u6392\u522b\u5885\u7ea6190\u33a1\u8986\u76d6\uff0c\u4e24\u53f0\u65e5\u7acbEX-\u8212\u4eab160\u5355\u98ce\u6247\u4e3b\u673a\u5404\u62d64\u53f0\u5185\u673a\uff0c\u603b8\u53f0\u5185\u673a\u3002\u8d1f\u4e00\u697c+\u4e00\u697c\u5171\u7528\u4e3b\u673a1\uff08\u9ad8\u9891\u6d3b\u52a8\u533a\uff09\uff0c\u4e8c\u697c\u72ec\u7acb\u4e3b\u673a2\uff08\u5367\u5ba4\u9759\u533a\uff09\u3002\u5ba2\u9910\u538567\u33a1\u91c7\u7528\u53cc71\u578b\u5e76\u8054\uff0c\u51b7\u91cf14.2kW\u5145\u8db3\u8986\u76d6\u3002\u642d\u914d\u8d1f\u4e00\u697c\u65e5\u7acb\u65b0\u98ceFM-350H2 + \u5fb7\u56fd\u6c49\u5821\u9601\u7535\u5730\u6696GMTX-230V2 41\u33a1\uff0c\u4e09\u5c42\u697c\u51b7\u6696\u65b0\u98ce\u4e00\u5e94\u4ff1\u5168\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m2\" class=\"wp-block-heading\">\u4e8c\u3001\u9700\u6c42\u8bca\u65ad\u4e0e\u65b9\u6848\u65b9\u5411<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6838\u5fc3\u8bc9\u6c42<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u7cfb\u7edf<\/th><th>\u5ba2\u6237\u5173\u6ce8\u70b9<\/th><th>\u65b9\u6848\u65b9\u5411<\/th><\/tr><tr><td>\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u5ba2\u9910\u538567\u33a1\u8d85\u5927\u7a7a\u95f4\uff0c\u5355\u53f0\u5185\u673a\u51b7\u4e0d\u4e0b\u6765<\/td><td>\u53cc71\u578b\u5e76\u8054\uff08\u603b\u51b7\u91cf14.2kW\uff09\uff0c212W\/\u33a1\u9ad8\u6807\u51c6\uff0c\u4e24\u53f0\u5185\u673a\u00b145\u00b0\u6446\u53f6\u4e92\u76f8\u8865\u5145<\/td><\/tr><tr><td>\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u4e00\u697c\u548c\u4e8c\u697c\u65e0\u5730\u6696\uff0c\u7a7a\u8c03\u51ac\u5929\u8981\u80fd\u5236\u70ed<\/td><td>\u8212\u4eab160\u5236\u70ed17kW\/\u53f0\uff0c\u5236\u70ed\u8fd0\u884c-21\u2103~17\u2103\uff0c\u6696\u4ece\u8db3\u8d77\u8986\u76d6\u5168\u5c4b<\/td><\/tr><tr><td>\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u5bd2\u6691\u5047\u5916\u51fa\u65c5\u6e38\uff0c\u5e73\u65f6\u5c45\u4f4f\u65f6\u95f4\u4e0d\u5b9a<\/td><td>WiFi\u578b\u7ebf\u63a7\u5668\u8fdc\u7a0b\u63a7\u5236\uff0c\u968f\u65f6\u542f\u505c\uff1b\u53cc\u4e3b\u673a\u5206\u5c42\u72ec\u7acb\uff0c\u5173\u4e00\u5c42\u7701\u4e00\u5c42<\/td><\/tr><tr><td>\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u8d1f\u4e00\u697c41\u33a1\u6311\u9ad8\u533a\uff0c\u5c42\u9ad8\u8f83\u9ad8\u6015\u51b7\u4e0d\u4e0b\u6765<\/td><td>71\u578b\u5927\u51b7\u91cf\u5185\u673a+3D\u51fa\u98ce\u53e3\uff0c\u6c14\u6d41\u8986\u76d6\u6311\u9ad8\u7a7a\u95f4\uff0c\u5355\u4f4d\u51b7\u91cf173W\/\u33a1<\/td><\/tr><tr><td>\u65b0\u98ce\u7cfb\u7edf<\/td><td>\u8d1f\u4e00\u697c\u91c7\u5149\u901a\u98ce\u5dee\uff0c\u9700\u8981\u65b0\u98ce\u6362\u6c14<\/td><td>\u65e5\u7acb\u65b0\u98ceFM-350H2\uff0c350\/120m\u00b3\/h \u53cc\u901f\uff0c125W\u529f\u8017\uff0c\u8986\u76d665\u33a1<\/td><\/tr><tr><td>\u7535\u5730\u6696<\/td><td>\u8d1f\u4e00\u697c\u51ac\u5929\u9634\u51b7\u6f6e\u6e7f\uff0c\u9700\u8981\u5730\u6696\u63d0\u5347\u8212\u9002\u5ea6<\/td><td>\u5fb7\u56fd\u6c49\u5821\u9601\u7535\u5730\u669640\u33a1\uff0c\u6696\u4ece\u811a\u8d77\uff0c\u72ec\u7acb\u6e29\u63a7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u9700\u6c42-\u62c5\u5fc3-\u75db\u70b9\u4e09\u7ef4\u8bca\u65ad<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u7ef4\u5ea6<\/th><th>\u5177\u4f53\u8868\u73b0<\/th><th>\u6743\u91cd<\/th><\/tr><tr><td>\u75db\u70b9<\/td><td>\u5ba2\u9910\u538567\u33a1+\u8054\u6392\u522b\u5885\u5916\u5899\u6563\u70ed\uff0c\u6015\u590f\u5929\u4e0d\u591f\u51b7<\/td><td>\u2605\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u75db\u70b9<\/td><td>\u8d1f\u4e00\u697c\u6311\u9ad841\u33a1\u5c42\u9ad8\u8f83\u9ad8\uff0c\u7a7a\u8c03\u51b7\u6c14\u96be\u4ee5\u4e0b\u6c89\u5230\u6d3b\u52a8\u533a<\/td><td>\u2605\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u75db\u70b9<\/td><td>\u8d1f\u4e00\u697c\u91c7\u5149\u901a\u98ce\u5dee\uff0c\u51ac\u5929\u9634\u51b7\u6f6e\u6e7f<\/td><td>\u2605\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u62c5\u5fc3<\/td><td>\u5bd2\u6691\u5047\u5916\u51fa\u540e\u56de\u6765\uff0c\u4e24\u4e2a\u4e3b\u673a\u540c\u65f6\u51b7\u542f\u52a8\u4f1a\u4e0d\u4f1a\u7535\u8d39\u592a\u9ad8<\/td><td>\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u62c5\u5fc3<\/td><td>\u4e24\u53f0\u98ce\u76d8\u572867\u33a1\u5ba2\u9910\u5385\u540c\u65f6\u5f00\uff0c\u4f1a\u4e0d\u4f1a\u58f0\u97f3\u5927<\/td><td>\u2605\u2605\u2605<\/td><\/tr><tr><td>\u62c5\u5fc3<\/td><td>\u90e8\u5206\u623f\u95f4\u5bd2\u6691\u5047\u957f\u671f\u4e0d\u7528\uff0c\u7a7a\u8c03\u4f1a\u4e0d\u4f1a\u95f2\u7f6e\u635f\u8017<\/td><td>\u2605\u2605\u2605<\/td><\/tr><tr><td>\u9700\u6c42<\/td><td>\u4e09\u5c42\u697c\u6bcf\u5c42\u80fd\u72ec\u7acb\u63a7\u6e29\uff0c\u51fa\u53bb\u65c5\u6e38\u53ef\u8fdc\u7a0b\u5173\u505c<\/td><td>\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u9700\u6c42<\/td><td>\u8054\u6392\u522b\u5885\u957f\u671f\u4f7f\u7528\u7a33\u5b9a\u53ef\u9760\uff0c\u552e\u540e\u6709\u4fdd\u969c<\/td><td>\u2605\u2605\u2605\u2605<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83c\udfc6 \u6838\u5fc3\u8bbe\u8ba1\u903b\u8f91\uff1a<\/strong> \u8054\u6392\u522b\u5885\u5171\u4e09\u5c42\u7ea6190\u33a1\uff0c\u91c7\u7528<strong>\u53cc\u4e3b\u673a\u5206\u5c42\u63a7\u5236<\/strong>\u7b56\u7565\u2014\u2014\u4e3b\u673a1\u62d6\u5e26\u8d1f\u4e00\u697c+\u4e00\u697c\uff08\u65e5\u5e38\u6d3b\u52a8\u9ad8\u9891\u533a\uff09\uff0c\u4e3b\u673a2\u62d6\u5e26\u4e8c\u697c\uff08\u5367\u5ba4\u9759\u533a\uff09\u3002\u4e24\u53f0160\u4e3b\u673a\u5404\u62d64\u53f0\u5185\u673a\uff0c\u603b8\u53f0\u5185\u673a\u51b7\u91cf39.4kW\uff0c\u603b\u8d85\u914d\u7387127.1%\uff0c\u5904\u4e8e\u9ec4\u91d1\u533a\u95f4\uff08100%~130%\uff09\u3002\u5173\u952e\u8bbe\u8ba1\u70b9\uff1a\u2460\u5ba2\u9910\u538567\u33a1\u91c7\u7528\u53cc71\u578b\u5e76\u8054\uff0c212W\/\u33a1\u51b7\u91cf\u6807\u51c6\uff0c\u5e94\u5bf9\u8054\u6392\u522b\u5885\u5916\u5899\u6563\u70ed\u548c\u6210\u90fd\u590f\u5b63\u9ad8\u6e29\uff1b\u2461\u8d1f\u4e00\u697c\u6311\u9ad8\u533a41\u33a1\u914d71\u578b\u5927\u51b7\u91cf\uff0c\u5355\u4f4d173W\/\u33a1\uff0c\u5efa\u8bae\u52a0\u88c53D\u51fa\u98ce\u53e3\u589e\u5f3a\u6c14\u6d41\u4e0b\u6c89\uff1b\u2462\u4e00\u697c\u548c\u4e8c\u697c\u65e0\u5730\u6696\uff0c\u7a7a\u8c03\u9700\u6ee1\u8db3\u51ac\u5b63\u5236\u70ed\uff0c\u8212\u4eab160\u5236\u70ed17kW\/\u53f0\u8986\u76d6\u5145\u5206\uff1b\u2463\u53cc\u4e3b\u673a\u5206\u5c42\u72ec\u7acb\u63a7\u5236\uff0c\u51fa\u53bb\u65c5\u6e38\u53ef\u7528\u624b\u673a\u8fdc\u7a0b\u5173\u505c\u4e00\u5c42\uff0c\u4e8c\u5c42\u5367\u5ba4\u533a\u7167\u5e38\u7528\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m3\" class=\"wp-block-heading\">\u4e09\u3001\u65b9\u6848\u914d\u7f6e\u8be6\u60c5<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">3.1 \u7a7a\u8c03\u5ba4\u5916\u4e3b\u673a \u00d7 2\u53f0<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u7cfb\u5217<\/th><th>\u578b\u53f7<\/th><th>\u5236\u51b7\u91cf<\/th><th>\u5236\u70ed\u91cf<\/th><th>APF\u80fd\u6548<\/th><th>\u538b\u7f29\u673a<\/th><th>\u8fd0\u884c\u8303\u56f4<\/th><th>\u566a\u97f3<\/th><th>\u7535\u6e90<\/th><\/tr><tr><td>\u65e5\u7acbEX-\u8212\u4eab<\/td><td>RAS-160HRNAQ<\/td><td>15.5 kW<\/td><td>17.0 kW<\/td><td>5.50\uff08\u4e00\u7ea7\uff09<\/td><td>\u5bbd\u9891\u9ad8\u8f6c\u901f \u00b7 \u5168\u76f4\u6d41\u53d8\u9891<\/td><td>\u5236\u51b7 -5\u2103~59\u2103 \/ \u5236\u70ed -21\u2103~17\u2103<\/td><td>54 dB(A)<\/td><td>220V\u5355\u76f8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u53c2\u6570<\/th><th>\u503c<\/th><th>\u53c2\u6570<\/th><th>\u503c<\/th><\/tr><tr><td>\u5916\u5f62\u5c3a\u5bf8 H\u00d7W\u00d7D<\/td><td>770\u00d7980\u00d7360 mm<\/td><td>\u51c0\u91cd<\/td><td>71 kg<\/td><\/tr><tr><td>\u98ce\u6247\u7c7b\u578b<\/td><td>\u5355\u98ce\u6247<\/td><td>\u51b7\u5a92<\/td><td>R410A \/ 3.0 kg<\/td><\/tr><tr><td>\u6c14\u7ba1\/\u6db2\u7ba1\u53e3\u5f84<\/td><td>\u03a615.88 \/ \u03a69.53 mm<\/td><td>APF\u80fd\u6548<\/td><td>5.50\uff08\u8d85\u4e00\u7ea7\uff09<\/td><\/tr><tr><td>\u6700\u5927\u914d\u7ba1\u603b\u957f<\/td><td>120m<\/td><td>\u5185\u5916\u673a\u9ad8\u5dee<\/td><td>30m<\/td><\/tr><tr><td>\u6700\u591a\u8fde\u63a5\u5185\u673a<\/td><td>10\u53f0<\/td><td>\u5185\u673a\u95f4\u9ad8\u5dee<\/td><td>15m<\/td><\/tr><tr><td>\u8054\u673a\u914d\u6bd4\u8303\u56f4<\/td><td colspan=\"3\">50%~130%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6570\u91cf\uff1a2\u53f0<\/strong>\uff08\u4e3b\u673a1\u2192\u8d1f\u4e00\u697c+\u4e00\u697c \/ \u4e3b\u673a2\u2192\u4e8c\u697c\uff09| \u4e24\u53f0\u5408\u8ba1\u5236\u51b7\u91cf 31.0kW<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.2 \u7a7a\u8c03\u5ba4\u5185\u673a\u914d\u7f6e\uff088\u53f0\u8d85\u8584\u98ce\u7ba1\u673a\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25b8 \u4e3b\u673a1\u533a\u57df\uff1a\u8d1f\u4e00\u5c42 + \u4e00\u5c42\uff08\u65e5\u5e38\u6d3b\u52a8\u9ad8\u9891\u533a\uff09<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u53f0\u6570<\/th><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u6311\u9ad8\u533a<\/td><td>41\u33a1<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>7.1kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5939\u5c42\u7535\u7ade\u5ba4<\/td><td>10\u33a1<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>1.8kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385A<\/td><td>67\u33a1<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>7.1kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u6b21\u5367<\/td><td>18.5\u33a1<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>4.0kW<\/td><td>1\u53f0<\/td><\/tr><tr><td colspan=\"3\"><strong>\u4e3b\u673a1\u5c0f\u8ba1<\/strong><\/td><td colspan=\"2\"><strong>4\u53f0<\/strong><\/td><td><strong>20.0 kW<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3b\u673a1\u8d85\u914d\u7387\uff1a20.0 \u00f7 15.5 = <strong>129.0%<\/strong>\uff08\u6c1f\u7cfb\u7edf\u5141\u8bb8\u2264130%\uff0c\u5408\u7406 \u2705\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25b8 \u4e3b\u673a2\u533a\u57df\uff1a\u4e00\u5c42\u5ba2\u9910\u5385 + \u4e8c\u5c42\uff08\u5367\u5ba4\u9759\u533a\uff09<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u53f0\u6570<\/th><\/tr><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385B<\/td><td>67\u33a1<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>7.1kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u4e3b\u5367<\/td><td>25.5\u33a1<\/td><td>RPIZ-56FSNAQD\/P<\/td><td>5.6kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u513f\u7ae5\u623f<\/td><td>19.5\u33a1<\/td><td>RPIZ-45FSNAQD\/P<\/td><td>4.5kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u4e66\u623f<\/td><td>8.7\u33a1<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2.2kW<\/td><td>1\u53f0<\/td><\/tr><tr><td colspan=\"3\"><strong>\u4e3b\u673a2\u5c0f\u8ba1<\/strong><\/td><td colspan=\"2\"><strong>4\u53f0<\/strong><\/td><td><strong>19.4 kW<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3b\u673a2\u8d85\u914d\u7387\uff1a19.4 \u00f7 15.5 = <strong>125.2%<\/strong>\uff08\u5408\u7406 \u2705\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th colspan=\"3\">\u603b\u8ba1<\/th><th>8\u53f0<\/th><th>39.4 kW<\/th><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u603b\u8d85\u914d\u7387\uff1a39.4 \u00f7 31.0 = <strong>127.1%<\/strong>\uff08\u53cc\u4e3b\u673a\u603b\u989d\u5904\u4e8e\u9ec4\u91d1\u533a\u95f4100%~130%\uff09<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.3 \u5206\u673a\u903b\u8f91\u8bf4\u660e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f53\u524d\u5206\u673a\u65b9\u5f0f\uff08\u5ba2\u6237\u6307\u5b9a\uff09\uff1a<\/strong> \u4e3b\u673a1\u62d6\u8d1f\u4e00\u697c71+18 + \u4e00\u697c\u5ba2\u9910\u538571+\u6b21\u536740\uff084\u53f0\uff09\uff0c\u4e3b\u673a2\u62d6\u4e00\u697c\u5ba2\u9910\u538571 + \u4e8c\u697c\u4e3b\u536756+\u513f\u7ae5\u623f45+\u4e66\u623f22\uff084\u53f0\uff09\u3002\u4e24\u53f0\u4e3b\u673a\u5404\u62d64\u53f0\u3001\u8d1f\u8377\u5747\u7b49\uff08129% \/ 125%\uff09\uff0c\u4e00\u697c67\u33a1\u5ba2\u9910\u5385\u7684\u53cc71\u578b\u5404\u6302\u4e00\u53f0\u4e3b\u673a\u4f9b\u7535\uff0c\u4efb\u4e00\u4e3b\u673a\u6545\u969c\u65f6\u5ba2\u9910\u5385\u4ecd\u6709\u72ec\u7acb\u7a7a\u8c03\u53ef\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 \u5907\u9009\u5206\u673a\u65b9\u6848\uff1a<\/strong> \u82e5\u8ffd\u6c42\u66f4\u6e05\u6670\u7684\u5206\u5c42\u72ec\u7acb\u63a7\u5236\u903b\u8f91\u2014\u2014\u53ef\u5c06<strong>\u4e3b\u673a1\u4e13\u95e8\u8d1f\u8d23\u8d1f\u4e00\u697c+\u4e00\u697c\uff08\u8d1f\u4e00\u697c71+18 + \u4e00\u697c71\u00d72 + \u6b21\u536740\uff0c\u51715\u53f0\uff0c27.1kW\uff09<\/strong>\uff0c\u8d85\u914d\u7387\u7ea6175%\uff0c\u5df2\u8d85\u51fa\u6c1f\u7cfb\u7edf130%\u4e0a\u9650\uff0c<strong style=\"color:#e63946;\">\u4e0d\u5efa\u8bae\u91c7\u7528\u6b64\u65b9\u6848<\/strong>\u3002\u5efa\u8bae\u7ef4\u6301\u5f53\u524d\u5206\u673a\u65b9\u5f0f\uff0c\u65e2\u80fd\u4fdd\u6301\u5206\u5c42\u903b\u8f91\u6e05\u6670\uff08\u9ad8\u6d3b\u52a8\u533a vs \u5367\u5ba4\u533a\u76f8\u5bf9\u72ec\u7acb\uff09\uff0c\u53c8\u63a7\u5236\u5728\u884c\u4e1a\u5141\u8bb8\u8d85\u914d\u8303\u56f4\u5185\u3002\u5f53\u524d\u65b9\u6848\u4e24\u53f0\u4e3b\u673a\u8d1f\u8377\u5747\u8861\uff0c\u5ba2\u9910\u5385\u53cc71\u5206\u5c5e\u4e24\u53f0\u4e3b\u673a\u662f\u989d\u5916\u5197\u4f59\u4f18\u52bf\u3002<\/p>\n\n\n\n<div class=\"banner-box\">\n<h3 style=\"color:#fff; margin-top:0;\">\u26a1 \u53cc71\u578b\u5e76\u8054 \u00b7 \u5ba2\u9910\u538567\u33a1\u5168\u8986\u76d6<\/h3>\n<p style=\"color:#fff; opacity:0.9; margin-bottom:0;\">\u4e24\u53f071\u578b\u98ce\u76d8\uff08\u603b\u51b7\u91cf14.2kW\uff0c212W\/\u33a1\uff09\u5206\u5c5e\u4e24\u53f0\u4e3b\u673a\u72ec\u7acb\u4f9b\u7535 \u00b145\u00b0\u6446\u53f6\u4e92\u76f8\u8865\u5145 \u2192 \u6bcf\u4e2a\u89d2\u843d\u6e29\u5ea6\u5747\u5300\uff0c\u4e00\u53f0\u4e3b\u673a\u6545\u969c\u4e5f\u4e0d\u5f71\u54cd\u5ba2\u9910\u5385\u5236\u51b7<\/p>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">3.4 \u65b0\u98ce\u7cfb\u7edf\u914d\u7f6e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u7c7b\u578b<\/th><th>\u98ce\u91cf<\/th><th>\u9002\u7528\u9762\u79ef<\/th><th>\u5b89\u88c5\u533a\u57df<\/th><th>\u529f\u80fd<\/th><\/tr><tr><td>\u65e5\u7acb\u65b0\u98ce<\/td><td>350\/120 m\u00b3\/h \u53cc\u901f<\/td><td>\u7ea665\u33a1\uff08\u8d1f\u4e00\u697c\u4f11\u95f2\u538541\u33a1+\u5939\u5c4224\u33a1\uff09<\/td><td>\u8d1f\u4e00\u697c<\/td><td>\u4e24\u6863\u98ce\u91cf\uff0c125W\u4f4e\u529f\u8017\uff0c\u6362\u6c14\u9664\u6e7f\u9632\u9709<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b0\u98ce\u91cf\u6838\u7b97\uff1a<\/strong> \u8d1f\u4e00\u697c\u8986\u76d6\u9762\u79ef65\u33a1\uff08\u4f11\u95f2\u538541\u33a1 + \u5939\u5c4224\u33a1\uff09\uff0c350m\u00b3\/h \u00f7 65\u33a1 = 5.4\u6b21\/\u5c0f\u65f6\u6362\u6c14 \u2192 \u8fdc\u8d85\u56fd\u68071.0\u6b21\/\u5c0f\u65f6 \u2705\u3002\u5927\u98ce\u91cf\u6a21\u5f0f\uff08350m\u00b3\/h\uff09\u5e94\u5bf9\u805a\u4f1a\u9ad8\u5cf0\u671f\uff0c\u5c0f\u98ce\u91cf\u6a21\u5f0f\uff08120m\u00b3\/h\uff0c24dB\uff09\u591c\u95f4\u5b89\u9759\u6362\u6c14\u4e0d\u6253\u6270\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b0\u98ce\u54c1\u724c\u53ca\u578b\u53f7\uff1a<\/strong>\u65e5\u7acb\u65b0\u98ce FM-350H2\uff0c\u5927\u98ce\u91cf350 m\u00b3\/h \/ \u5c0f\u98ce\u91cf120 m\u00b3\/h\uff0c\u8bbe\u5907\u529f\u7387125W\uff0c\u8fd0\u884c\u566a\u97f333\/24 dB(A)\uff0c\u9759\u538b100\/40 Pa\uff0c\u6cd5\u5170\u53e3\u5f84\u03c6120\uff0c\u8bbe\u5907\u5c3a\u5bf8500\u00d7300\u00d7260 mm\uff0c\u8986\u76d6\u8d1f\u4e00\u5c42\u4f11\u95f2\u538541\u33a1 + \u5939\u5c42\u4f11\u95f2\u538524\u33a1 = \u517165\u33a1\u3002<\/p>\n\n\n\n<div class=\"photo-placeholder\">\n<p style=\"margin:0; font-size:16px;\"><strong>\ud83d\udcf8 \u6b64\u5904\u6dfb\u52a0\u65b0\u98ce\u7ba1\u8def\/\u8bbe\u5907\u914d\u7f6e\u56fe<\/strong><\/p>\n<p style=\"margin:8px 0 0 0; font-size:13px;\">\u5728\u53ef\u89c6\u5316\u7f16\u8f91\u5668\u91cc\uff0c\u628a\u5149\u6807\u653e\u5728\u8fd9\u91cc \u2192 \u70b9\u300c+\u300d\u2192 \u9009\u300c\u56fe\u7247\u300d\u2192 \u4e0a\u4f20\u65b0\u98ce\u914d\u7f6e\u7167\u7247<\/p>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">3.5 \u7535\u5730\u6696\u7cfb\u7edf\u914d\u7f6e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u54c1\u724c<\/th><th>\u94fa\u8bbe\u9762\u79ef<\/th><th>\u5b89\u88c5\u533a\u57df<\/th><th>\u603b\u529f\u7387<\/th><th>\u63a7\u5236\u65b9\u5f0f<\/th><\/tr><tr><td><strong>\u5fb7\u56fd\u6c49\u5821\u9601<\/strong> Halmburger<\/td><td>41 \u33a1<\/td><td>\u8d1f\u4e00\u697c\u4f11\u95f2\u5385<\/td><td><strong>4600W<\/strong>\uff08\u7ea6112W\/\u33a1\uff09<\/td><td>\u66fc\u745e\u5fb7\u72ec\u7acb\u6e29\u63a7\u5668<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea7\u54c1\u578b\u53f7\uff1a<\/strong>\u6c49\u5821\u9601 GMTX-230V2 \u53d1\u70ed\u7535\u7f06\uff0c\u642d\u914d GMTX-2300 \u7535\u7f06\uff0c\u8bfa\u5c14\u54c1\u724c\u6324\u5851\u677f + \u4f1f\u661f\u54c1\u724c\u53cd\u5c04\u819c\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u90e8\u4ef6<\/th><th>\u54c1\u724c\/\u578b\u53f7<\/th><th>\u8bf4\u660e<\/th><\/tr><tr><td>\u53d1\u70ed\u7535\u7f06<\/td><td>\u6c49\u5821\u9601 GMTX-230V2 \/ GMTX-2300<\/td><td>\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\uff0c\u53cc\u5bfc\u53cc\u5c4f\u853d<\/td><\/tr><tr><td>\u6324\u5851\u677f<\/td><td>\u8bfa\u5c14<\/td><td>\u4fdd\u6e29\u9694\u70ed<\/td><\/tr><tr><td>\u53cd\u5c04\u819c<\/td><td>\u4f1f\u661f<\/td><td>\u70ed\u91cf\u5411\u4e0a\u53cd\u5c04\uff0c\u51cf\u5c11\u5411\u4e0b\u635f\u5931<\/td><\/tr><tr><td>\u6e29\u63a7\u5668<\/td><td>\u66fc\u745e\u5fb7<\/td><td>\u72ec\u7acb\u5206\u533a\u63a7\u6e29<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u8981\u70b9\uff1a<\/strong> \u8d1f\u4e00\u697c\u51ac\u5b63\u9634\u51b7\u6f6e\u6e7f\uff0c\u7535\u5730\u669641\u33a1\u6696\u4ece\u811a\u8d77\uff0c\u642d\u914d\u65b0\u98ceFM-350H2\u6392\u6e7f\uff0c\u6253\u9020\u5e72\u723d\u6e29\u6696\u7684\u5730\u4e0b\u6d3b\u52a8\u7a7a\u95f4\u3002\u603b\u529f\u73874.6kW\uff0c\u72ec\u7acb\u6e29\u63a7\u5668\u4e0e\u7a7a\u8c03\u7cfb\u7edf\u5206\u79bb\uff0c\u4e92\u4e0d\u5e72\u6270\u3002\u7535\u6e90\u9884\u7559\u6309\u5355\u8def4.6kW\u914d\u7f6e\uff0c\u5efa\u8bae\u72ec\u7acb20A\u56de\u8def\u3002<\/p>\n\n\n\n<div class=\"photo-placeholder\">\n<p style=\"margin:0; font-size:16px;\"><strong>\ud83d\udcf8 \u6b64\u5904\u6dfb\u52a0\u7535\u5730\u6696\u914d\u7f6e\/\u94fa\u8bbe\u56fe<\/strong><\/p>\n<p style=\"margin:8px 0 0 0; font-size:13px;\">\u5728\u53ef\u89c6\u5316\u7f16\u8f91\u5668\u91cc\uff0c\u628a\u5149\u6807\u653e\u5728\u8fd9\u91cc \u2192 \u70b9\u300c+\u300d\u2192 \u9009\u300c\u56fe\u7247\u300d\u2192 \u4e0a\u4f20\u6c49\u5821\u9601\u7535\u5730\u6696\u914d\u7f6e\u7167\u7247<\/p>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m4\" class=\"wp-block-heading\">\u56db\u3001\u51b7\u8d1f\u8377\u6838\u7b97<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u914d\u7f6e\u5185\u673a<\/th><th>\u51b7\u91cf<\/th><th>\u51b7\u8d1f\u8377\u6307\u6807<\/th><th>\u5224\u65ad<\/th><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u6311\u9ad8\u533a<\/td><td>41\u33a1<\/td><td>71\u578b \u00d71<\/td><td>7.1 kW<\/td><td>173 W\/\u33a1<\/td><td>\u26a0\ufe0f \u5c42\u9ad8\u8f83\u9ad8\uff0c\u5efa\u8bae3D\u98ce\u53e3\u589e\u5f3a\u6c14\u6d41\u4e0b\u6c89<\/td><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u7535\u7ade\u5ba4<\/td><td>10\u33a1<\/td><td>18\u578b \u00d71<\/td><td>1.8 kW<\/td><td>180 W\/\u33a1<\/td><td>\u2705 \u5c01\u95ed\u7a7a\u95f4\u5145\u8db3<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>67\u33a1<\/td><td>71\u578b \u00d72<\/td><td>14.2 kW<\/td><td>212 W\/\u33a1<\/td><td>\u2705 \u9ad8\u6807\u51c6\uff0c\u5e94\u5bf9\u8054\u6392\u522b\u5885\u5916\u5899\u6563\u70ed<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u6b21\u5367<\/td><td>18.5\u33a1<\/td><td>40\u578b \u00d71<\/td><td>4.0 kW<\/td><td>216 W\/\u33a1<\/td><td>\u2705 \u5145\u8db3<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u4e3b\u5367<\/td><td>25.5\u33a1<\/td><td>56\u578b \u00d71<\/td><td>5.6 kW<\/td><td>220 W\/\u33a1<\/td><td>\u2705 \u5927\u4e3b\u5367\u914d\u7f6e\u5230\u4f4d<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u513f\u7ae5\u623f<\/td><td>19.5\u33a1<\/td><td>45\u578b \u00d71<\/td><td>4.5 kW<\/td><td>231 W\/\u33a1<\/td><td>\u2705 \u5145\u8db3<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u4e66\u623f<\/td><td>8.7\u33a1<\/td><td>22\u578b \u00d71<\/td><td>2.2 kW<\/td><td>253 W\/\u33a1<\/td><td>\u2705 \u5145\u8db3<\/td><\/tr><tr><td colspan=\"5\"><strong>\u8bbe\u8ba1\u6807\u51c6<\/strong><\/td><td colspan=\"2\">GB 50736-2012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5236\u70ed\u6821\u6838\uff1a<\/strong> \u4e00\u697c\u548c\u4e8c\u697c\u65e0\u5730\u6696\uff0c\u51ac\u5b63\u5236\u70ed\u4f9d\u8d56\u7a7a\u8c03\u3002\u8212\u4eab160\u5236\u70ed\u91cf17.0kW\u00d72 = 34.0kW\uff0c8\u53f0\u5185\u673a\u603b\u5236\u70ed\u91cf\u7ea644kW\uff0c\u8fde\u63a5\u7387\u4e0d\u8d85130%\uff0c\u51ac\u5b63\u6b63\u5e38\u5236\u70ed\u6709\u4fdd\u969c \u2705\u3002\u6210\u90fd\u51ac\u5b63\u6e7f\u51b7\uff0c\u5efa\u8bae\u5236\u70ed\u65f6\u5ba2\u9910\u5385\u53cc71\u578b\u540c\u6b65\u5f00\u542f\uff0c\u5229\u7528\u4e24\u53f0\u5185\u673a\u5439\u98ce\u8986\u76d6\u9762\u79ef\u5927\u7684\u4f18\u52bf\u5feb\u901f\u5347\u6e29\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m5\" class=\"wp-block-heading\">\u4e94\u3001\u6700\u7ec8\u4f18\u60e0\u62a5\u4ef7<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u9879\u76ee<\/th><th>\u914d\u7f6e<\/th><th>\u6570\u91cf<\/th><\/tr><tr><td>\u65e5\u7acbEX-\u8212\u4eab160\u5355\u98ce\u6247\u4e3b\u673a<\/td><td>RAS-160HRNAQ<\/td><td>2\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a71\u578b<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>3\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a56\u578b<\/td><td>RPIZ-56FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a45\u578b<\/td><td>RPIZ-45FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a40\u578b<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a22\u578b<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a18\u578b<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u65e5\u7acb\u65b0\u98ce FM-350H2<\/td><td>350\/120 m\u00b3\/h\uff0c125W\uff0c33\/24dB<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u5fb7\u56fd\u6c49\u5821\u9601\u7535\u5730\u6696 GMTX-230V2<\/td><td>GMTX-2300 \u53d1\u70ed\u7535\u7f06\uff0c41\u33a1<\/td><td>1\u5957<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u62a5\u4ef7\u660e\u7ec6\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u9879\u76ee<\/th><th>\u91d1\u989d<\/th><\/tr><tr><td>\u65e5\u7acbEX-\u8212\u4eab160\u4e8c\u62d6\u516b\u4e2d\u592e\u7a7a\u8c03\uff08\u8bbe\u5907\uff09<\/td><td>63500<\/td><\/tr><tr><td>\u7a7a\u8c03\u5b89\u88c5\u8d39\uff08\u4e24\u53f0\u4e3b\u673a+8\u53f0\u5185\u673a\uff09<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb\u65b0\u98ce FM-350H2\uff08\u8bbe\u5907+\u5b89\u88c5\uff09<\/td><td>4200<\/td><\/tr><tr><td>\u5fb7\u56fd\u6c49\u5821\u9601\u7535\u5730\u6696 GMTX-230V2 41\u33a1\uff08\u8bbe\u5907+\u5b89\u88c5\uff09<\/td><td>10000<\/td><\/tr><tr><td>\u51cf\uff1a\u4f18\u60e0<\/td><td>500<\/td><\/tr><tr><td>\u51cf\uff1a\u56fd\u8865<\/td><td>1500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m6\" class=\"wp-block-heading\">\u516d\u3001\u7ade\u54c1\u5bf9\u6bd4\u5206\u6790<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u5bf9\u6bd4\u9879<\/th><th>\u65e5\u7acbEX-\u8212\u4eab160\u4e8c\u62d6\u516b\uff08\u6211\u65b9\uff09<\/th><th>\u683c\u529bSTAR 160\u4e8c\u62d6\u516b<\/th><th>\u7f8e\u7684\u7406\u60f3\u5bb6160\u4e8c\u62d6\u516b<\/th><\/tr><tr><td>\u5355\u53f0\u5236\u51b7\u91cf<\/td><td>15.5 kW<\/td><td>15.5 kW<\/td><td>15.5 kW<\/td><\/tr><tr><td>APF\u80fd\u6548<\/td><td><strong>5.50 \u4e00\u7ea7\u80fd\u6548<\/strong><\/td><td>\u7ea64.80<\/td><td>\u7ea65.00<\/td><\/tr><tr><td>\u5185\u673a\u6700\u4f4e\u566a\u97f3<\/td><td><strong>17 dB<\/strong><\/td><td>22 dB<\/td><td>20 dB<\/td><\/tr><tr><td>\u5236\u51b7\u8fd0\u884c\u4e0a\u9650<\/td><td><strong>59\u2103 \u9ad8\u6e29\u4e0d\u505c\u673a<\/strong><\/td><td>52\u2103<\/td><td>52\u2103<\/td><\/tr><tr><td>\u5236\u70ed\u8fd0\u884c\u4e0b\u9650<\/td><td><strong>-21\u2103 \u7167\u6837\u5236\u70ed<\/strong><\/td><td>-15\u2103<\/td><td>-15\u2103<\/td><\/tr><tr><td>\u538b\u7f29\u673a\u7c7b\u578b<\/td><td><strong>8\u7ea712\u69fd\u5bbd\u9891\u7535\u673a \u00b7 \u5168\u76f4\u6d41\u53d8\u9891<\/strong><\/td><td>\u683c\u529b\u53cc\u8f6c\u5b50<\/td><td>\u7f8e\u829d\u53cc\u8f6c\u5b50<\/td><\/tr><tr><td>\u81ea\u6e05\u6d01<\/td><td><strong>\u4e8c\u6b21\u7ed3\u51b0\u4e13\u5229\u81ea\u6e05\u6d01<\/strong><\/td><td>\u666e\u901a\u81ea\u6e05\u6d01<\/td><td>\u666e\u901a\u81ea\u6e05\u6d01<\/td><\/tr><tr><td>\u53cc\u4e3b\u673a\u5197\u4f59<\/td><td><strong>\u5ba2\u9910\u5385\u53cc71\u5206\u5c5e\u4e24\u53f0\u4e3b\u673a\uff0c\u4e92\u5907\u5197\u4f59<\/strong><\/td><td>\u901a\u5e38\u5355\u4e3b\u673a\u65b9\u6848\uff0c\u65e0\u5197\u4f59<\/td><td>\u901a\u5e38\u5355\u4e3b\u673a\u65b9\u6848\uff0c\u65e0\u5197\u4f59<\/td><\/tr><tr><td>\u8fdc\u7a0b\u63a7\u5236<\/td><td><strong>WiFi\u7ebf\u63a7\u5668+\u65e5\u7acb\u667a\u5bb6APP<\/strong><\/td><td>\u9700\u989d\u5916\u8d2d\u4e70\u6a21\u5757<\/td><td>\u57fa\u7840WiFi<\/td><\/tr><tr><td>\u8d28\u4fdd<\/td><td><strong>\u5165\u4f1a\u5ef6\u4fdd10\u5e74<\/strong><\/td><td>6\u5e74<\/td><td>6\u5e74<\/td><\/tr><tr><td>\u5b89\u88c5\u6807\u51c6<\/td><td><strong>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u7cbe\u5de5\u6807\u51c6<\/strong><\/td><td>\u666e\u901a\u6807\u51c6<\/td><td>\u666e\u901a\u6807\u51c6<\/td><\/tr><tr><td>\u54c1\u724c\u539f\u4ea7\u5730<\/td><td>\u65e5\u672c\u6280\u672f\/\u9752\u5c9b\u5408\u8d44<\/td><td>\u73e0\u6d77\u56fd\u4ea7<\/td><td>\u987a\u5fb7\u56fd\u4ea7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acbEX-\u8212\u4eab\u5728APF\u80fd\u6548\uff085.50\uff09\u3001\u6781\u7aef\u5de5\u51b5\u8303\u56f4\uff08\u5236\u51b759\u2103\/\u5236\u70ed-21\u2103\uff09\u3001\u9759\u97f3\uff0817dB\uff09\u3001\u4e13\u5229\u81ea\u6e05\u6d01\u3001\u53cc\u4e3b\u673a\u5197\u4f59\u67b6\u6784\u4e94\u5927\u7ef4\u5ea6\u5168\u9762\u9886\u5148\u3002\u5bf9\u4e8e\u8054\u6392\u522b\u5885\u8fd9\u7c7b\u5927\u9762\u79ef\u591a\u697c\u5c42\u573a\u666f\uff0c\u53cc\u4e3b\u673a\u5206\u5c42\u72ec\u7acb\u63a7\u5236\u5929\u7136\u4f18\u4e8e\u5355\u4e3b\u673a\u65b9\u6848\u2014\u2014\u51fa\u53bb\u65c5\u6e38\u5173\u4e00\u5c42\u7701\u4e00\u5c42\u7535\u8d39\uff0c\u56de\u6765\u51b7\u542f\u52a8\u4e5f\u4e0d\u4f1a\u4e24\u53f0\u4e3b\u673a\u540c\u65f6\u6ee1\u8d1f\u8377\u51b2\u51fb\u7535\u7f51\u30028\u7ea712\u69fd\u5bbd\u9891\u7535\u673a\u6bd4\u666e\u901a6\u7ea79\u69fd\u8f6c\u77e9\u4f4e40%\uff0c\u5728\u90e8\u5206\u8d1f\u8377\uff08\u65e5\u5e38\u53ea\u5f00\u51e0\u4e2a\u623f\u95f4\uff09\u65f6\u80fd\u6548\u6bd4\u5353\u8d8a\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m7\" class=\"wp-block-heading\">\u4e03\u3001\u65b9\u6848\u6838\u5fc3\u4f18\u52bf<\/h2>\n\n\n\n<div class=\"advantage-grid\">\n<div class=\"advantage-card\">\n<strong>\ud83c\udfe1 \u53cc\u4e3b\u673a\u5206\u5c42<\/strong>\n<span>\u8d1f\u4e00+\u4e00\u697c\/\u4e8c\u697c\u72ec\u7acb\u63a7\u5236<br>\u51fa\u6e38\u5173\u4e00\u5c42\uff0c\u7701\u4e00\u5c42\u7535\u8d39<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83c\udfaf \u53cc71\u5e76\u8054<\/strong>\n<span>\u5ba2\u9910\u538567\u33a1\u5168\u8986\u76d6<br>212W\/\u33a1\uff0c\u6781\u7aef\u9ad8\u6e29\u65e0\u5fe7<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83d\udd04 \u4e92\u5907\u5197\u4f59<\/strong>\n<span>\u5ba2\u9910\u5385\u53cc71\u5206\u5c5e\u4e24\u4e3b\u673a<br>\u4efb\u4e00\u6545\u969c\u4ecd\u6709\u51b7\u6c14\u53ef\u7528<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83c\udf21\ufe0f \u5bbd\u57df\u8fd0\u884c<\/strong>\n<span>\u5236\u51b7-5~59\u2103\/\u5236\u70ed-21~17\u2103<br>\u6210\u90fd\u56db\u5b63\u6781\u7aef\u5929\u6c14\u4ece\u5bb9<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83d\udcf1 \u8fdc\u7a0b\u667a\u63a7<\/strong>\n<span>WiFi\u7ebf\u63a7\u5668+APP\u8fdc\u7a0b<br>\u5bd2\u6691\u5047\u5916\u51fa\u968f\u65f6\u5173\u505c\u542f\u505c<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83d\udd25 \u4e09\u7cfb\u7edf\u96c6\u6210<\/strong>\n<span>\u7a7a\u8c03+\u65b0\u98ce+\u7535\u5730\u6696<br>\u51b7\u6696\u65b0\u98ce\u4e00\u5e94\u4ff1\u5168<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83d\udd07 17dB\u9759\u97f3<\/strong>\n<span>\u5367\u5ba4\u533a\u6700\u4f4e17dB\u8fd0\u884c<br>\u56fe\u4e66\u9986\u7ea7\u5b89\u9759\u7761\u7720<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\u2744\ufe0f \u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01<\/strong>\n<span>\u81a8\u80c0\u529b\u5265\u79bb\u6df1\u5c42\u6c61\u57a2<br>60\u2103\u9ad8\u6e29\u9664\u83cc30\u5206\u949f<\/span>\n<\/div>\n<div class=\"advantage-card\">\n<strong>\ud83d\udee1\ufe0f 10\u5e74\u8d28\u4fdd<\/strong>\n<span>\u5165\u4f1a\u5ef6\u4fdd10\u5e74<br>\u94bb\u77f3\u5b89\u88c5\u5546\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/span>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m8\" class=\"wp-block-heading\">\u516b\u3001\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u670d\u52a1\u9879\u76ee<\/th><th>\u627f\u8bfa\u5185\u5bb9<\/th><\/tr><tr><td>\ud83c\udd93 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\ud83d\udcd0 \u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/td><\/tr><tr><td>\ud83d\udd27 \u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><\/tr><tr><td>\ud83d\udcb0 \u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td>\ud83c\udfd7\ufe0f \u5de5\u7a0b\u8d28\u4fdd<\/td><td>5\u5e74\u8d77<\/td><\/tr><tr><td>\ud83c\udf96\ufe0f \u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m9\" class=\"wp-block-heading\">\u4e5d\u3001\u5408\u540c\u914d\u7f6e<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg\" alt=\"\" class=\"wp-image-4783\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-htpz.jpg\" alt=\"\" class=\"wp-image-4784\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-htpz.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-htpz-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-htpz-1.jpg\" alt=\"\" class=\"wp-image-4785\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-htpz-1.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-htpz-1-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-htpz.jpg\" alt=\"\" class=\"wp-image-4786\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-htpz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-htpz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-htpz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-htpz.jpg\" alt=\"\" class=\"wp-image-4787\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-htpz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-htpz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-htpz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m10\" class=\"wp-block-heading\">\u5341\u3001\u73b0\u573a\u52d8\u6d4b\u5b9a\u4f4d<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-xckc.jpg\" alt=\"\" class=\"wp-image-4788\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-xckc.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-xckc-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-xckc.jpg\" alt=\"\" class=\"wp-image-4789\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-xckc.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-xckc-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-xckc.jpg\" alt=\"\" class=\"wp-image-4790\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-xckc.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-xckc-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-xckc-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m11\" class=\"wp-block-heading\">\u5341\u4e00\u3001\u8bbe\u8ba1\u56fe\u7eb8<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-tz-1024x724.png\" alt=\"\" class=\"wp-image-4791\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-tz-1024x724.png 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-tz-300x212.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-tz-768x543.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-tz-1536x1086.png 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-tz-2048x1448.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-tz-1024x724.png\" alt=\"\" class=\"wp-image-4792\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-tz-1024x724.png 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-tz-300x212.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-tz-768x543.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-tz-1536x1086.png 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-tz-2048x1448.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-tz-1024x724.png\" alt=\"\" class=\"wp-image-4793\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-tz-1024x724.png 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-tz-300x212.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-tz-768x543.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-tz-1536x1086.png 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-tz-2048x1448.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m12\" class=\"wp-block-heading\">\u5341\u4e8c\u3001\u6309\u56fe\u65bd\u5de5<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4794\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4795\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4796\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4797\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4798\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-07-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4799\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-07-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-07-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-07-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4800\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4801\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4802\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-ktxfaz.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-ktxfaz-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4803\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-ktxfaz.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-ktxfaz-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-14-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4804\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-14-ktxfaz.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-14-ktxfaz-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz-1.jpg\" alt=\"\" class=\"wp-image-4805\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz-1.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-11-ktxfaz-1-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-12-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4806\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-12-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-12-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-12-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-13-ktxfaz.jpg\" alt=\"\" class=\"wp-image-4807\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-13-ktxfaz.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-13-ktxfaz-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-13-ktxfaz-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m13\" class=\"wp-block-heading\">\u5341\u4e09\u3001\u76d1\u7406\u8bb0\u5f55<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-jlys.jpg\" alt=\"\" class=\"wp-image-4808\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-jlys.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-01-jlys-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-jlys.jpg\" alt=\"\" class=\"wp-image-4809\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-jlys.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-02-jlys-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-jlys.jpg\" alt=\"\" class=\"wp-image-4810\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-jlys.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-03-jlys-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-jlys.jpg\" alt=\"\" class=\"wp-image-4811\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-jlys.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-jlys-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-04-jlys-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-jlys.jpg\" alt=\"\" class=\"wp-image-4812\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-jlys.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-jlys-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-jlys-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-jlys.jpg\" alt=\"\" class=\"wp-image-4813\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-jlys.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-jlys-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-06-jlys-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-08-jlys.jpg\" alt=\"\" class=\"wp-image-4814\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-08-jlys.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-08-jlys-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-08-jlys-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-jlys.jpg\" alt=\"\" class=\"wp-image-4815\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-jlys.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-jlys-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-09-jlys-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-jlys.jpg\" alt=\"\" class=\"wp-image-4816\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-jlys.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-jlys-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-10-jlys-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m14\" class=\"wp-block-heading\">\u5341\u56db\u3001\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udee0\ufe0f \u7cfb\u7edf\u8c03\u8bd5\u62a5\u544a\u3001\u4f7f\u7528\u6307\u5bfc\u7b7e\u6536\u3001\u4fdd\u4fee\u5361\u53d1\u653e\u3001\u56de\u8bbf\u8bb0\u5f55\u7b49\u552e\u540e\u670d\u52a1\u5185\u5bb9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u8c03\u8bd5\u8bb0\u5f55<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u9879\u76ee<\/th><th>\u8bb0\u5f55<\/th><\/tr><tr><td><strong>\u8c03\u8bd5\u65e5\u671f<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u8c03\u8bd5\u4eba\u5458<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u4e3b\u673a1\u5236\u51b7\u8bd5\u8fd0\u884c\u53c2\u6570<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u4e3b\u673a2\u5236\u51b7\u8bd5\u8fd0\u884c\u53c2\u6570<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u5404\u623f\u95f4\u51fa\u98ce\u53e3\u6e29\u5ea6<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u65b0\u98ce\u98ce\u901f\u5b9e\u6d4b<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u7535\u5730\u6696\u901a\u7535\u6d4b\u8bd5<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u8fd0\u884c\u566a\u97f3<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u5ba2\u6237\u7b7e\u6536<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u4f7f\u7528\u6559\u5b66<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u2610 \u7a7a\u8c03\u64cd\u4f5c\u6559\u5b66\uff08\u4e3b\u673a1\/\u4e3b\u673a2\u5206\u522b\u8bf4\u660e\uff09\u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n\n\n\n<li>\u2610 \u7ebf\u63a7\u5668\/WiFi APP\u4f7f\u7528\u6559\u5b66 \u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n\n\n\n<li>\u2610 \u65b0\u98ce\u64cd\u4f5c\u6559\u5b66 \u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n\n\n\n<li>\u2610 \u7535\u5730\u6696\u6e29\u63a7\u5668\u64cd\u4f5c\u6559\u5b66 \u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n\n\n\n<li>\u2610 \u6ee4\u7f51\u6e05\u6d17\u5468\u671f\u8bf4\u660e \u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n\n\n\n<li>\u2610 \u5bd2\u6691\u5047\u5916\u51fa\u5173\u673a\u6d41\u7a0b\u6559\u5b66 \u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n\n\n\n<li>\u2610 \u4f7f\u7528\u8bf4\u660e\u4e66\u4ea4\u4ed8 \u2014\u2014 \u8bf7\u8865\u5145\u5b8c\u6210\u65e5\u671f<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u4fdd\u4fee\u4fe1\u606f<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u9879\u76ee<\/th><th>\u8be6\u60c5<\/th><\/tr><tr><td><strong>\u4fdd\u4fee\u5361\u7f16\u53f7<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u4fdd\u4fee\u8d77\u59cb\u65e5<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u7a7a\u8c03\u5ef6\u4fdd\u81f3<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u65b0\u98ce\u4fdd\u4fee\u81f3<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u7535\u5730\u6696\u4fdd\u4fee\u81f3<\/strong><\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><tr><td><strong>\u5de5\u7a0b\u8d28\u4fdd\u671f<\/strong><\/td><td>5\u5e74<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u56de\u8bbf\u8bb0\u5f55<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c1\u6b21\u56de\u8bbf\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u65e5\u671f<\/th><th>\u56de\u8bbf\u5185\u5bb9<\/th><th>\u5ba2\u6237\u53cd\u9988<\/th><th>\u5904\u7406\u7ed3\u679c<\/th><\/tr><tr><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c2\u6b21\u56de\u8bbf\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u65e5\u671f<\/th><th>\u56de\u8bbf\u5185\u5bb9<\/th><th>\u5ba2\u6237\u53cd\u9988<\/th><th>\u5904\u7406\u7ed3\u679c<\/th><\/tr><tr><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5e74\u5ea6\u56de\u8bbf\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u65e5\u671f<\/th><th>\u56de\u8bbf\u5185\u5bb9<\/th><th>\u5ba2\u6237\u53cd\u9988<\/th><th>\u5904\u7406\u7ed3\u679c<\/th><\/tr><tr><td>\u8bf7\u8865\u5145<\/td><td>\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><td>\u8bf7\u8865\u5145<\/td><td>\u8bf7\u8865\u5145<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 \u5982\u4f55\u6dfb\u52a0\u65b0\u56de\u8bbf\u8bb0\u5f55\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u53ef\u89c6\u5316\u7f16\u8f91\u5668\u91cc\uff0c\u628a\u5149\u6807\u653e\u5728\u6700\u540e\u4e00\u4e2a\u56de\u8bbf\u8bb0\u5f55\u8868\u683c\u7684\u4efb\u610f\u4f4d\u7f6e \u2192 \u8868\u683c\u5de5\u5177\u680f\u4f1a\u51fa\u73b0 \u2192 \u70b9\u300c\u5728\u4e0b\u65b9\u63d2\u5165\u884c\u300d\u5c31\u80fd\u52a0\u65b0\u884c\u4e86\uff01<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"m15\" class=\"wp-block-heading\">\u5341\u4e94\u3001\u65b9\u6848\u987e\u95ee<\/h2>\n\n\n\n<div style=\"text-align:center; padding:20px; background:#f8f9fa; border-radius:8px;\">\n<p style=\"font-size:18px; margin:0;\">\ud83d\udc69\u200d\ud83d\udcbc <strong>\u90ed\u52c7\u79c0<\/strong> \u00b7 \u9f99\u8109\u6696\u901a<\/p>\n<p style=\"font-size:16px; color:#1d3557; margin:8px 0;\">\ud83d\udcf1 181-0083-9248<\/p>\n<p style=\"font-size:12px; color:#999; margin:0;\">\ud83c\udfe2 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u59cb\u4e8e2004<\/p>\n<p style=\"font-size:12px; color:#999; margin:4px 0;\">\ud83d\udccd \u5357\u5bcc\u68ee\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/p>\n<p style=\"font-size:12px; color:#999; margin:0;\">\ud83d\udccd \u5317\u5bcc\u68ee\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/p>\n<p style=\"font-size:12px; color:#999; margin:4px 0;\">\ud83d\udcde \u95e8\u5e97\u70ed\u7ebf\uff1a028-86131795 \/ 028-65272586<\/p>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u6848\u4f8b\u7248\u672c V1.0 \u00b7 \u5efa\u6863 2026\u5e746\u670827\u65e5<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u672c\u65b9\u6848\u6240\u6709\u6280\u672f\u53c2\u6570\u5f15\u7528 GB 50736-2012 \u53ca\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u624b\u518c\uff0c\u53ef\u72ec\u7acb\u9a8c\u8bc1<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<\/em><\/p>\n\n\n\n<script>\n\/\/ ===== \u624b\u98ce\u7434\u6298\u53e0\u529f\u80fd =====\n(function() {\n  var headings = document.querySelectorAll('h2.wp-block-heading');\n  headings.forEach(function(h, i) {\n    if (i === 0) return;\n    h.style.cursor = 'pointer';\n    var arrow = document.createElement('span');\n    arrow.textContent = ' \u25bc';\n    arrow.className = 'h2-arrow';\n    h.appendChild(arrow);\n    h.addEventListener('click', function() {\n      this.classList.toggle('accordion-closed');\n      var arr = this.querySelector('.h2-arrow');\n      if (this.classList.contains('accordion-closed')) {\n        arr.textContent = ' \u25b6';\n      } else {\n        arr.textContent = ' \u25bc';\n      }\n    });\n  });\n})();\n\n\/\/ ===== \u56de\u5230\u9876\u90e8\u6309\u94ae =====\n(function() {\n  var btn = document.createElement('button');\n  btn.textContent = '\u2191';\n  btn.style.cssText = 'position:fixed;bottom:30px;right:30px;z-index:9999;width:45px;height:45px;border-radius:50%;background:#e63946;color:#fff;border:none;font-size:22px;cursor:pointer;display:none;box-shadow:0 2px 10px rgba(0,0,0,0.3);';\n  document.body.appendChild(btn);\n  btn.addEventListener('click', function() {\n    window.scrollTo({ top: 0, behavior: 'smooth' });\n  });\n  window.addEventListener('scroll', function() {\n    btn.style.display = window.scrollY > 300 ? 'block' : 'none';\n  });\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u660e\u4fe1\u5929\u5e9c\u58f9\u53f7 \u00b7 \u65e5\u7acbEX-\u8212\u4eab160\u4e8c [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4775","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=4775\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u660e\u4fe1\u5929\u5e9c\u58f9\u53f7 \u00b7 \u65e5\u7acbEX-\u8212\u4eab160\u4e8c [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=4775\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-19T07:00:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"814\" \/>\n\t<meta property=\"og:image:height\" content=\"611\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"12 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775\",\"name\":\"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/mxttfyh-lns-05-htpz.jpg\",\"datePublished\":\"2026-06-27T08:14:18+00:00\",\"dateModified\":\"2026-07-19T07:00:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/mxttfyh-lns-05-htpz.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/mxttfyh-lns-05-htpz.jpg\",\"width\":814,\"height\":611},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4775#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=4775","og_locale":"zh_CN","og_type":"article","og_title":"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u660e\u4fe1\u5929\u5e9c\u58f9\u53f7 \u00b7 \u65e5\u7acbEX-\u8212\u4eab160\u4e8c [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=4775","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-19T07:00:57+00:00","og_image":[{"width":814,"height":611,"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"12 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=4775","url":"https:\/\/longmai-nt.com\/?page_id=4775","name":"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=4775#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=4775#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg","datePublished":"2026-06-27T08:14:18+00:00","dateModified":"2026-07-19T07:00:57+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=4775#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=4775"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=4775#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/mxttfyh-lns-05-htpz.jpg","width":814,"height":611},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=4775#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5929\u5e9c\u58f9\u53f7L\u5973\u58eb\uff0c\u65e5\u7acb\u8212\u4eab2\u62d68\u52a0\u8d1f\u4e00\u5c42\u7535\u5730\u6696\u6863\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4775","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4775"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4775\/revisions"}],"predecessor-version":[{"id":7090,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4775\/revisions\/7090"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4775"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}