{"id":4846,"date":"2026-06-28T11:14:24","date_gmt":"2026-06-28T03:14:24","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=4846"},"modified":"2026-11-11T22:11:44","modified_gmt":"2026-11-11T14:11:44","slug":"%e8%94%b7%e8%96%87%e9%83%a1-l%e5%a5%b3%e5%a3%ab%e5%85%a8%e6%95%88%e4%ba%8c%e8%81%94%e4%be%9b%e6%a1%a3%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=4846","title":{"rendered":"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66"},"content":{"rendered":"\n\n<div class=\"db-root\" style=\"max-width:100%;overflow-x:hidden;word-wrap:break-word;box-sizing:border-box;\">\n<style>\n\/* \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n \u9f99\u8109\u6696\u901a \u00b7 \u4eea\u8868\u76d8\u753b\u5e03 \u8bbe\u8ba1\u7cfb\u7edf\n \u6863\u6848\u7248 \u00b7 \u4e09\u9636\u6bb5 \u00b7 \u5de6\u4fa7Stepper + \u53f3\u4fa7\u8be6\u60c5\u9762\u677f\n CSS\u547d\u540d\u7a7a\u95f4\uff1a.db-root\uff08WordPress\u9694\u79bb\uff09\n \u79fb\u52a8\u7aef\u65ad\u70b9\uff1a739px\n \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 *\/\n.db-root{\n --db-bg:#e6e6e6;--db-card:#fff;--db-card2:#ebebeb;--db-card3:#e0e0e0;\n --db-txt:#1a1a1a;--db-txt2:#555;--db-txt3:#777;\n --db-bd:rgba(0,0,0,0.22);--db-bd2:rgba(0,0,0,0.12);\n --db-rad-sm:6px;--db-rad:8px;--db-rad-lg:12px;\n --db-font:system-ui,-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;\n --db-blue:#1D6BA8;--db-blue-bg:rgba(29,107,168,0.08);--db-blue-bd:rgba(29,107,168,0.25);\n --db-green:#0F6E56;--db-green-bg:rgba(15,110,86,0.08);--db-green-bd:rgba(15,110,86,0.25);\n --db-purple:#534AB7;--db-purple-bg:rgba(83,74,183,0.08);--db-purple-bd:rgba(83,74,183,0.25);\n --db-amber:#BA7517;--db-amber-bg:rgba(186,117,23,0.08);--db-amber-bd:rgba(186,117,23,0.25);\n --db-red:#A32D2D;--db-red-bg:rgba(163,45,45,0.08);--db-red-bd:rgba(163,45,45,0.25);\n --db-olive:#639922;--db-olive-bg:rgba(99,153,34,0.08);\n --db-sky:#378ADD;--db-sky-bg:rgba(55,138,221,0.08);\n --db-warm:#D85A30;--db-warm-bg:rgba(216,90,48,0.08);\n font-family:var(--db-font);font-size:14px;color:var(--db-txt);line-height:1.6;\n background:var(--db-bg);padding:16px;margin:0;text-align:left;\n -webkit-font-smoothing:antialiased;\n}\n.db-root,.db-root *{box-sizing:border-box;margin:0;padding:0;}\n.db-root a{color:var(--db-blue);text-decoration:none;}\n.db-root table{width:100%;border-collapse:collapse;font-size:12px;}\n.db-root th,.db-root td{padding:7px 10px;text-align:left;border-bottom:0.5px solid var(--db-bd2);}\n.db-root th{font-weight:500;color:var(--db-txt2);font-size:11px;background:var(--db-card2);}\n.db-root td{color:var(--db-txt);}\n.db-root tr:last-child td,.db-root tr:last-child th{border-bottom:none;}\n\/* \u2550\u2550 \u9876\u90e8\u6863\u6848\u680f \u2550\u2550 *\/\n.db-topbar{background:var(--db-card);border-radius:var(--db-rad-lg);border:0.5px solid var(--db-bd);\n padding:16px 20px;margin-bottom:14px;display:flex;align-items:center;gap:14px;flex-wrap:wrap;}\n.db-avatar{width:42px;height:42px;border-radius:50%;display:flex;align-items:center;\n justify-content:center;font-weight:500;font-size:17px;color:#fff;flex-shrink:0;}\n.db-topinfo{flex:1;min-width:0;}\n.db-topname{font-size:15px;font-weight:500;color:var(--db-txt);}\n.db-topmeta{font-size:12px;color:var(--db-txt2);margin-top:3px;display:flex;flex-wrap:wrap;gap:0 16px;}\n.db-topbadge{font-size:11px;padding:3px 11px;border-radius:12px;font-weight:500;flex-shrink:0;}\n.db-topid{font-size:11px;color:var(--db-txt3);padding:4px 0;}\n\/* \u2550\u2550 \u9636\u6bb5\u6807\u7b7e\u680f \u2550\u2550 *\/\n.db-phase-bar{display:flex;gap:8px;margin-bottom:12px;flex-wrap:wrap;}\n.db-phase-btn{padding:7px 16px;border-radius:20px;font-size:12px;font-weight:500;cursor:pointer;\n border:0.5px solid var(--db-bd);background:var(--db-card);color:var(--db-txt2);transition:all .2s;}\n.db-phase-btn:hover{background:var(--db-card2);}\n.db-phase-btn.db-phase-active{color:#fff;}\n\/* \u2550\u2550 \u53cc\u680f\u4e3b\u4f53 \u2550\u2550 *\/\n.db-main{display:flex;gap:12px;flex-wrap:wrap;align-items:flex-start;}\n.db-left{width:220px;flex-shrink:0;display:flex;flex-direction:column;gap:10px;}\n.db-right{flex:1;min-width:320px;display:flex;flex-direction:column;gap:10px;}\n\/* \u2550\u2550 Stepper \u2550\u2550 *\/\n.db-stepper{background:var(--db-card);border-radius:var(--db-rad-lg);border:0.5px solid var(--db-bd);padding:6px;}\n.db-step{padding:8px 10px;border-radius:var(--db-rad);cursor:pointer;font-size:12px;\n display:flex;align-items:flex-start;gap:8px;transition:background .15s;margin:2px 0;}\n.db-step:hover{background:var(--db-card2);}\n.db-step.db-active{border:0.5px solid currentColor;}\n.db-step-num{display:inline-flex;align-items:center;justify-content:center;width:22px;height:22px;\n border-radius:50%;font-size:11px;font-weight:500;flex-shrink:0;margin-top:1px;\n background:var(--db-card3);color:var(--db-txt3);}\n.db-step.db-active .db-step-num{color:#fff;}\n.db-step-body{flex:1;min-width:0;}\n.db-step-title{font-weight:400;color:var(--db-txt2);line-height:1.4;}\n.db-step.db-active .db-step-title{font-weight:500;color:var(--db-txt);}\n.db-step-desc{font-size:10px;color:var(--db-txt3);margin-top:1px;line-height:1.3;}\n.db-step-divider{height:0.5px;background:var(--db-bd2);margin:4px 0;}\n.db-step-group{font-size:10px;font-weight:500;color:var(--db-txt3);padding:6px 10px 2px;\n letter-spacing:0.5px;text-transform:uppercase;}\n\/* \u2550\u2550 \u6307\u6807\u5361 \u2550\u2550 *\/\n.db-kpis{display:grid;grid-template-columns:1fr 1fr;gap:8px;margin-bottom:10px;}\n.db-kpi-3{display:grid;grid-template-columns:1fr 1fr 1fr;gap:8px;margin-bottom:10px;}\n.db-kpi{background:var(--db-card2);border-radius:var(--db-rad);padding:12px;text-align:center;}\n.db-kpi-val{font-size:19px;font-weight:500;margin:0;}\n.db-kpi-lbl{font-size:11px;color:var(--db-txt2);margin:3px 0 0;}\n.db-kpi.db-hi-blue{border:1px solid var(--db-blue-bd);background:var(--db-blue-bg);}\n.db-kpi.db-hi-blue .db-kpi-val{color:var(--db-blue);}\n.db-kpi.db-hi-green{border:1px solid var(--db-green-bd);background:var(--db-green-bg);}\n.db-kpi.db-hi-green .db-kpi-val{color:var(--db-green);}\n.db-kpi.db-hi-amber{border:1px solid var(--db-amber-bd);background:var(--db-amber-bg);}\n.db-kpi.db-hi-amber .db-kpi-val{color:var(--db-amber);}\n.db-kpi.db-hi-purple{border:1px solid var(--db-purple-bd);background:var(--db-purple-bg);}\n.db-kpi.db-hi-purple .db-kpi-val{color:var(--db-purple);}\n\/* \u2550\u2550 \u8be6\u60c5\u9762\u677f \u2550\u2550 *\/\n.db-panel{background:var(--db-card);border-radius:var(--db-rad-lg);border:0.5px solid var(--db-bd);padding:20px;}\n.db-phead{display:flex;align-items:center;gap:10px;margin-bottom:14px;padding-bottom:12px;\n border-bottom:0.5px solid var(--db-bd2);}\n.db-phead-num{display:inline-flex;align-items:center;justify-content:center;width:26px;height:26px;\n border-radius:var(--db-rad-sm);font-size:13px;font-weight:500;color:#fff;flex-shrink:0;}\n.db-phead-title{font-size:15px;font-weight:500;color:var(--db-txt);}\n.db-phead-sub{font-size:12px;color:var(--db-txt3);margin-left:auto;}\n\/* \u2550\u2550 \u63a8\u8350\u5361 \u2550\u2550 *\/\n.db-recbar{background:var(--db-card);border-radius:var(--db-rad-lg);border:0.5px solid var(--db-bd);padding:12px 16px;}\n.db-recbar-title{font-size:11px;font-weight:500;color:var(--db-txt2);margin-bottom:8px;}\n.db-rectags{display:flex;flex-wrap:wrap;gap:6px;}\n.db-tag{padding:4px 10px;border-radius:12px;font-size:11px;font-weight:500;}\n.db-tag-blue{background:#E6F1FB;color:var(--db-sky);}\n.db-tag-green{background:#E1F5EE;color:var(--db-green);}\n.db-tag-purple{background:#EEEDFE;color:var(--db-purple);}\n.db-tag-amber{background:#FAEEDA;color:var(--db-amber);}\n.db-tag-red{background:#FCEBEB;color:var(--db-red);}\n.db-tag-olive{background:#EEF7E0;color:var(--db-olive);}\n.db-tag-sep{font-size:11px;color:var(--db-txt3);}\n\/* \u2550\u2550 \u56fe\u8868 \u2550\u2550 *\/\n.db-chart-wrap{background:var(--db-card2);border-radius:var(--db-rad);padding:14px;margin-bottom:10px;}\n.db-chart-title{font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:10px;}\n.db-chart-wrap canvas{width:100%!important;height:220px!important;}\n\/* \u2550\u2550 \u75db\u70b9\u5361 \u2550\u2550 *\/\n.db-pain-grid{display:grid;grid-template-columns:1fr 1fr;gap:9px;margin-bottom:10px;}\n.db-pain-card{padding:12px 14px;border-radius:var(--db-rad);border-left:3px solid;font-size:12px;line-height:1.7;}\n.db-pain-card .db-ph{font-weight:500;font-size:12px;margin-bottom:5px;}\n.db-pain-card .db-pd{color:var(--db-txt2);}\n\/* \u2550\u2550 \u4fe1\u606f\u6761 \u2550\u2550 *\/\n.db-info{padding:12px 14px;border-radius:var(--db-rad);font-size:12px;color:var(--db-txt2);line-height:1.7;margin-bottom:10px;}\n\/* \u2550\u2550 \u4e09\u5bf9\u6bd4\u5361 \u2550\u2550 *\/\n.db-cmp3{display:grid;grid-template-columns:1fr 1fr 1fr;gap:10px;margin-bottom:10px;}\n.db-cmp2{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin-bottom:10px;}\n.db-cc{background:var(--db-card2);border-radius:var(--db-rad);padding:14px;border:0.5px solid var(--db-bd);}\n.db-cc.db-cc-star{border-width:2px;}\n.db-cc .db-cc-badge{display:inline-block;font-size:11px;padding:3px 10px;border-radius:10px;font-weight:500;margin-bottom:7px;}\n.db-cc .db-cc-title{font-size:13px;font-weight:500;color:var(--db-txt);margin:0 0 7px;}\n.db-cc .db-cc-spec{font-size:11px;color:var(--db-txt2);line-height:1.8;margin:0 0 8px;}\n.db-cc .db-cc-price{font-size:15px;font-weight:500;margin:0 0 4px;}\n\/* \u2550\u2550 \u6b65\u9aa4\u5361 \u2550\u2550 *\/\n.db-steps-grid{display:grid;grid-template-columns:1fr 1fr;gap:9px;margin-bottom:10px;}\n.db-step-card{padding:13px;border-radius:var(--db-rad);background:var(--db-card2);font-size:12px;}\n.db-step-card .db-sc-h{font-weight:500;color:var(--db-txt);margin-bottom:5px;font-size:13px;}\n.db-step-card .db-sc-d{color:var(--db-txt2);line-height:1.6;}\n\/* \u2550\u2550 \u627f\u8bfa\u5361 \u2550\u2550 *\/\n.db-commit-grid{display:grid;grid-template-columns:1fr 1fr;gap:9px;margin-bottom:10px;}\n.db-commit-card{padding:13px;border-radius:var(--db-rad);background:var(--db-card2);font-size:12px;}\n.db-commit-card .db-cch{font-weight:500;color:var(--db-txt);margin-bottom:5px;}\n.db-commit-card .db-ccd{color:var(--db-txt2);line-height:1.6;}\n\/* \u2550\u2550 \u65f6\u95f4\u7ebf \u2550\u2550 *\/\n.db-timeline{display:flex;flex-direction:column;gap:0;margin-bottom:10px;}\n.db-tl-item{display:flex;gap:12px;align-items:flex-start;padding:10px 0;}\n.db-tl-item:not(:last-child){border-bottom:0.5px solid var(--db-bd2);}\n.db-tl-dot{width:28px;height:28px;border-radius:50%;display:flex;align-items:center;justify-content:center;font-size:11px;font-weight:500;color:#fff;flex-shrink:0;margin-top:2px;}\n.db-tl-body{flex:1;min-width:0;}\n.db-tl-h{font-size:13px;font-weight:500;color:var(--db-txt);margin-bottom:3px;}\n.db-tl-d{font-size:11px;color:var(--db-txt2);line-height:1.6;}\n\/* \u2550\u2550 \u9ad8\u4eae\u5355\u5143 \u2550\u2550 *\/\n.db-hi-blue{color:var(--db-blue)!important;font-weight:500;}\n.db-hi-green{color:var(--db-green)!important;font-weight:500;}\n.db-hi-amber{color:var(--db-amber)!important;font-weight:500;}\n.db-hi-red{color:var(--db-red)!important;font-weight:500;}\n.db-cell-hi{background:rgba(15,110,86,0.05);}\n\/* \u2550\u2550 \u62a5\u4ef7\u6c47\u603b \u2550\u2550 *\/\n.db-price-box{background:var(--db-blue-bg);border:1px solid var(--db-blue-bd);border-radius:var(--db-rad);padding:14px 16px;margin-bottom:10px;display:flex;align-items:center;justify-content:space-between;flex-wrap:wrap;gap:8px;}\n.db-price-box .db-pb-label{font-size:12px;color:var(--db-txt2);}\n.db-price-box .db-pb-val{font-size:20px;font-weight:500;color:var(--db-blue);}\n\/* \u2550\u2550 \u72b6\u6001 \u2550\u2550 *\/\n.db-status-row{display:flex;align-items:center;gap:8px;padding:9px 12px;border-radius:var(--db-rad);background:var(--db-card2);font-size:12px;margin-bottom:7px;}\n.db-status-dot{width:8px;height:8px;border-radius:50%;flex-shrink:0;}\n\/* \u2550\u2550 \u516d\u7ef4\u5ea6\u96f7\u8fbe \u2550\u2550 *\/\n.db-radar-wrap{display:grid;grid-template-columns:1fr 1fr;gap:8px;margin-bottom:10px;}\n.db-radar-item{background:var(--db-card2);border-radius:var(--db-rad);padding:10px 14px;display:flex;align-items:center;gap:10px;}\n.db-radar-bar-bg{flex:1;height:6px;background:rgba(0,0,0,0.08);border-radius:3px;overflow:hidden;}\n.db-radar-bar{height:100%;border-radius:3px;}\n.db-radar-label{font-size:11px;color:var(--db-txt2);white-space:nowrap;width:56px;}\n.db-radar-val{font-size:11px;font-weight:500;white-space:nowrap;width:40px;text-align:right;}\n\/* \u2550\u2550 \u9875\u811a \u2550\u2550 *\/\n.db-footer{text-align:center;padding:18px 0 6px;font-size:11px;color:var(--db-txt3);\n border-top:0.5px solid var(--db-bd2);margin-top:12px;}\n.db-footer a{color:var(--db-blue);}\n\/* \u2550\u2550 \u79fb\u52a8\u7aef 739px \u2550\u2550 *\/\n@media(max-width:739px){\n .db-root{padding:10px;}\n .db-topbar{padding:10px 12px;gap:8px;}\n .db-avatar{width:34px;height:34px;font-size:14px;}\n .db-topname{font-size:13px;line-height:1.4;word-break:break-all;}\n .db-topmeta{gap:0 10px;font-size:11px;}\n .db-topid{font-size:10px;}\n .db-topbadge{font-size:10px;padding:2px 8px;}\n .db-topbar{flex-wrap:wrap;}\n .db-topinfo{flex:1 1 0;min-width:0;}\n .db-left{width:100%;flex-direction:row;}\n .db-stepper{display:flex;overflow-x:auto;-webkit-overflow-scrolling:touch;padding:4px;}\n .db-step{min-width:90px;flex-direction:column;align-items:center;text-align:center;gap:4px;}\n .db-step-body{min-width:0;}\n .db-step-desc{display:none;}\n .db-step-group{display:none;}\n .db-step-divider{display:none;}\n .db-right{min-width:100%;}\n .db-kpis{grid-template-columns:1fr 1fr;}\n .db-kpi-3{grid-template-columns:1fr 1fr;}\n .db-pain-grid{grid-template-columns:1fr;}\n .db-cmp3{grid-template-columns:1fr;}\n .db-cmp2{grid-template-columns:1fr;}\n .db-steps-grid{grid-template-columns:1fr;}\n .db-commit-grid{grid-template-columns:1fr;}\n .db-radar-wrap{grid-template-columns:1fr;}\n .db-panel{padding:14px;}\n .db-phase-bar{gap:6px;}\n .db-phase-btn{padding:6px 12px;font-size:11px;}\n .db-root img{max-width:100%;height:auto;}\n}\n<\/style>\n\n<!-- \u2550\u2550 \u9876\u90e8\u6863\u6848\u680f \u2550\u2550 -->\n<div class=\"db-topbar\">\n <div class=\"db-avatar\" style=\"background:var(--db-warm)\">\u5218<\/div>\n <div class=\"db-topinfo\">\n <div style=\"display:flex;align-items:center;flex-wrap:wrap;gap:6px;\">\n <div class=\"db-topname\">\u5218\u5973\u58eb \u00b7 \u5168\u5c4b\u8212\u9002\u7cfb\u7edf \u00b7 150\u33a1 \u5ba2\u9910\u5385+\u4e09\u5367<\/div>\n <span class=\"db-topbadge\" style=\"background:var(--db-blue-bg);color:var(--db-blue)\">\u4e2d\u592e\u7a7a\u8c03<\/span>\n <span class=\"db-topbadge\" style=\"background:var(--db-amber-bg);color:var(--db-amber)\">\u5730\u6696<\/span>\n <\/div>\n <div class=\"db-topmeta\">\n <span>\u987e\u95ee\uff1a\u5f90\u65b0\u5e73<\/span>\n <span>\u7f16\u5236\uff1a2026\u5e746\u670823\u65e5<\/span>\n <span>\u7248\u672c\uff1a\u6863\u6848\u7248<\/span>\n <\/div>\n <div class=\"db-topid\">\u6863\u6848\u7f16\u53f7\uff1alns-qwj-bb-01 \u00b7 \u8054\u7cfb\u65b9\u5f0f\uff1a18227055065<\/div>\n <\/div>\n<\/div>\n\n<!-- \u2550\u2550 \u9636\u6bb5\u5207\u6362\u680f \u2550\u2550 -->\n<div class=\"db-phase-bar\" id=\"db-phase-bar\">\n <button class=\"db-phase-btn db-phase-active\" data-phase=\"1\" style=\"background:var(--db-warm);border-color:var(--db-warm);\">\u4e00\u9636\u6bb5\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/button>\n <button class=\"db-phase-btn\" data-phase=\"2\">\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/button>\n <button class=\"db-phase-btn\" data-phase=\"3\">\u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316<\/button>\n<\/div>\n\n<!-- \u2550\u2550 \u53cc\u680f\u4e3b\u4f53 \u2550\u2550 -->\n<div class=\"db-main\">\n <div class=\"db-left\">\n <div class=\"db-stepper\" id=\"db-stepper\"><\/div>\n <\/div>\n <div class=\"db-right\">\n <div class=\"db-panel\" id=\"db-panel\"><\/div>\n <div class=\"db-recbar\" id=\"db-recbar\"><\/div>\n <div id=\"db-chart-area\" style=\"display:none\">\n <div class=\"db-chart-wrap\">\n <p class=\"db-chart-title\" id=\"db-chart-title\"><\/p>\n <canvas id=\"db-chart\"><\/canvas>\n <\/div>\n <\/div>\n <\/div>\n<\/div>\n\n<div class=\"db-footer\">\n <div style=\"font-size:14px;font-weight:500;color:var(--db-txt);margin-bottom:6px;\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/div>\n \u9f99\u8109\u6696\u901a \u00b7 \u4e13\u6ce8\u4ee5\u79d1\u5b66\u8bbe\u8ba1\u5339\u914d\u771f\u5b9e\u751f\u6d3b<br>\n \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u59cb\u4e8e2004 \u00b7 \u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd<br>\n \u65b9\u6848\u987e\u95ee\uff1a\u5f90\u65b0\u5e73 \u00b7 18227055065\n<\/div>\n\n<script src=\"https:\/\/cdnjs.cloudflare.com\/ajax\/libs\/Chart.js\/4.4.1\/chart.umd.js\"><\/script>\n<script>\n(function(){\n\n\/* \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n \u9636\u6bb5\u6570\u636e \u00b7 \u5168\u90e8\u5185\u5bb9\n \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 *\/\nvar phases = {\n\n\/* \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500 \u4e00\u9636\u6bb5\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1 \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500 *\/\n1:[\n {num:1,title:'\u5ba2\u6237\u4fe1\u606f',desc:'\u57fa\u672c\u60c5\u51b5\u4e0e\u75db\u70b9',color:'#D85A30',bg:'rgba(216,90,48,0.08)',\n content:`\n<div class=\"db-kpis\" style=\"grid-template-columns:1fr 1fr 1fr\">\n <div class=\"db-kpi db-hi-blue\"><p class=\"db-kpi-val\">150\u33a1<\/p><p class=\"db-kpi-lbl\">\u91c7\u6696\u9762\u79ef<\/p><\/div>\n <div class=\"db-kpi db-hi-amber\"><p class=\"db-kpi-val\">4\u5ba4<\/p><p class=\"db-kpi-lbl\">\u6237\u578b\u7ed3\u6784<\/p><\/div>\n <div class=\"db-kpi db-hi-green\"><p class=\"db-kpi-val\">2026.6.23<\/p><p class=\"db-kpi-lbl\">\u65b9\u6848\u65e5\u671f<\/p><\/div>\n<\/div>\n<table style=\"margin-bottom:12px\">\n <tr><th style=\"width:110px\">\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><th>\u5907\u6ce8<\/th><\/tr>\n <tr><td>\u5ba2\u6237\u79f0\u547c<\/td><td>\u5218\u5973\u58eb<\/td><td>\u2014<\/td><\/tr>\n <tr><td>\u6237\u578b\u6982\u51b5<\/td><td>\u5ba2\u9910\u538575\u33a1 + \u4e3b\u53671(30\u33a1) + \u4e3b\u53672(30\u33a1) + \u6b21\u5367(14\u33a1)<\/td><td>\u56db\u4e2a\u529f\u80fd\u533a<\/td><\/tr>\n <tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>\u7ea6150\u33a1<\/td><td>\u542b\u5730\u6696\u5168\u8986\u76d6<\/td><\/tr>\n <tr><td>\u65b9\u6848\u5b9a\u4f4d<\/td><td>\u5168\u5c4b\u8212\u9002\u7cfb\u7edf\u6863\u6848\u4e66<\/td><td>\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696<\/td><\/tr>\n <tr><td>\u670d\u52a1\u5546<\/td><td>\u9f99\u8109\u6696\u901a\uff08\u59cb\u4e8e2004\uff09<\/td><td>2\u4e07+\u5bb6\u5ead<\/td><\/tr>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u6838\u5fc3\u75db\u70b9\u901f\u89c8<\/h4>\n<div class=\"db-pain-grid\">\n <div class=\"db-pain-card\" style=\"border-left-color:var(--db-blue);background:var(--db-blue-bg)\">\n <p class=\"db-ph\" style=\"color:var(--db-blue)\">\u2744\ufe0f \u6015\u51b7<\/p>\n <p class=\"db-pd\">\u51ac\u5929\u5bb6\u91cc\u8981\u6696\u548c\uff0c\u7a7a\u8c03\u5439\u51fa\u6765\u7684\u98ce\u4e0d\u80fd\u523a\u9aa8\u3002<br>\u2192 \u6c1f\u7cfb\u7edf\u51fa\u98ce7-12\u2103\uff08\u4f53\u611f\u523a\u6fc0\uff09\uff0c\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\uff08\u51c9\u800c\u4e0d\u5bd2\uff09<\/p>\n <\/div>\n <div class=\"db-pain-card\" style=\"border-left-color:var(--db-green);background:var(--db-green-bg)\">\n <p class=\"db-ph\" style=\"color:var(--db-green)\">\ud83c\udf3f \u5bf9\u7a7a\u6c14\u654f\u611f<\/p>\n <p class=\"db-pd\">\u5bb6\u91cc\u7a7a\u6c14\u8981\u5e72\u51c0\uff0c\u4e0d\u80fd\u6709\u5f02\u5473\u3001\u7ec6\u83cc\u3002<br>\u2192 PE\u51c0\u5316+\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6740\u83cc\uff0cPM2.5\u53bb\u9664\u738799%<\/p>\n <\/div>\n <div class=\"db-pain-card\" style=\"border-left-color:var(--db-amber);background:var(--db-amber-bg)\">\n <p class=\"db-ph\" style=\"color:var(--db-amber)\">\ud83d\udebf \u5bf9\u70ed\u6c34\u8212\u9002\u6027\u8981\u6c42\u9ad8<\/p>\n <p class=\"db-pd\">\u6d17\u6fa1\u6c34\u8981\u7a33\u5b9a\uff0c\u4e0d\u80fd\u5ffd\u51b7\u5ffd\u70ed\u3002<br>\u2192 \u72ec\u7acb\u70ed\u6c34\u5668+\u4e3b\u7ba1\u5faa\u73af\uff0c12L\/min\u4ee5\u4e0a\uff0c2-3\u79d2\u5373\u51fa<\/p>\n <\/div>\n <div class=\"db-pain-card\" style=\"border-left-color:var(--db-red);background:var(--db-red-bg)\">\n <p class=\"db-ph\" style=\"color:var(--db-red)\">\ud83d\udd27 \u62c5\u5fc3\u8d28\u4fdd\u3001\u589e\u9879\u3001\u552e\u540e<\/p>\n <p class=\"db-pd\">\u6015\u540e\u671f\u52a0\u94b1\uff0c\u6015\u574f\u4e86\u6ca1\u4eba\u7ba1\u3002<br>\u2192 \u5408\u540c\u5217\u660e\u6e05\u5355+10\u5e74\u8d28\u4fdd+24h\u54cd\u5e94+199\u5143\/\u5e74\u4f1a\u5458\u5236<\/p>\n <\/div>\n<\/div>\n<div class=\"db-info\" style=\"background:var(--db-warm-bg)\">\n <span style=\"font-weight:500;color:var(--db-warm)\">\ud83d\udca1 \u6838\u5fc3\u8bca\u65ad\uff1a<\/span>\u60a8\u4e0d\u662f\u8981\u4e00\u53f0\u7a7a\u8c03\uff0c\u60a8\u8981\u7684\u662f\u4e00\u4e2a10\u5e74\u540e\u4f9d\u7136\u8212\u9002\u3001\u7701\u5fc3\u3001\u7701\u94b1\u7684\u5bb6\u3002\u8fd9\u6b63\u662f\u9f99\u8109\u6696\u901a\u4ece2004\u5e74\u81f3\u4eca\u4e00\u76f4\u5728\u89e3\u51b3\u7684\u95ee\u9898\u3002\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u51ac\u5929\u771f\u6b63\u6696\u548c<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-green\">\u7a7a\u6c14\u6d01\u51c0\u65e0\u5f02\u5473<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-red\">10\u5e74\u7701\u5fc3\u65e0\u5fe7<\/span><\/div>'},\n\n {num:2,title:'\u9700\u6c42\u6df1\u5ea6\u89e3\u6790',desc:'\u80fd\u91cf\u7ba1\u7406\u89c6\u89d2',color:'#1D6BA8',bg:'rgba(29,107,168,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-blue-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-blue)\">\u80fd\u91cf\u7ba1\u7406\u6846\u67b6\uff1a<\/span>\u5c06\u60a8\u7684\u6bcf\u4e00\u4e2a\u75db\u70b9\u7ffb\u8bd1\u4e3a\"\u80fd\u91cf\u95ee\u9898\"\uff0c\u518d\u7528\u7cfb\u7edf\u8bbe\u8ba1\u6765\u89e3\u51b3\u5b83\u3002\n<\/div>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th style=\"width:110px\">\u60a8\u62c5\u5fc3\u7684<\/th><th>\u80fd\u91cf\u7ba1\u7406\u7ffb\u8bd1<\/th><th>\u65b9\u6848\u8bbe\u8ba1\u65b9\u5411<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\"\u6015\u51b7\"<\/td><td>\u5ba4\u5185\u70ed\u73af\u5883\u4e0d\u7a33\u5b9a\uff0c\u80fd\u91cf\u8f93\u51fa\u4e0d\u8db3\u6216\u5206\u5e03\u4e0d\u5747<\/td><td class=\"db-hi-blue\">\u63d0\u9ad8\u5236\u70ed\u6548\u7387\uff0c\u4f18\u5316\u6c14\u6d41\u7ec4\u7ec7<\/td><\/tr>\n <tr><td>\"\u8d39\u7528\u9ad8\"<\/td><td>\u80fd\u91cf\u8f93\u5165\u6210\u672c\u504f\u9ad8\uff0c\u6d6a\u8d39\u5927<\/td><td class=\"db-hi-green\">\u63d0\u9ad8\u80fd\u91cf\u7ba1\u7406\u6548\u7387\uff0c\u51cf\u5c11\u65e0\u6548\u80fd\u8017<\/td><\/tr>\n <tr><td>\"\u5ffd\u51b7\u5ffd\u70ed\"<\/td><td>\u80fd\u91cf\u8f93\u51fa\u4e0d\u7a33\u5b9a\uff0c\u9891\u7e41\u542f\u505c<\/td><td class=\"db-hi-amber\">\u964d\u4f4e\u542f\u505c\u9891\u7387\uff0c\u53d8\u9891\u7cbe\u51c6\u63a7\u5236<\/td><\/tr>\n <tr><td>\"\u574f\u4e86\u6ca1\u4eba\u7ba1\"<\/td><td>\u80fd\u91cf\u7cfb\u7edf\u7f3a\u4e4f\u6301\u7eed\u76d1\u63a7\u548c\u7ef4\u62a4<\/td><td class=\"db-hi-red\">\u5efa\u7acb\u9884\u8b66\u548c\u8ffd\u8e2a\u673a\u5236\uff0c10\u5e74\u8ddf\u8e2a<\/td><\/tr>\n <\/tbody>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u65b9\u6848\u9009\u62e9\u5173\u952e\u6982\u5ff5<\/h4>\n<div class=\"db-cmp2\" style=\"margin-bottom:10px\">\n <div class=\"db-cc db-cc-star\" style=\"border-color:var(--db-blue)\">\n <span class=\"db-cc-badge\" style=\"background:var(--db-blue-bg);color:var(--db-blue)\">\u65b9\u6848A \u00b7 \u5c0a\u777f\u5168\u6548<\/span>\n <div class=\"db-cc-title\">\u5929\u6c1f\u5730\u6c34 \u4e24\u8054\u4f9b<\/div>\n <div class=\"db-cc-spec\">\u2022 \u7a7a\u8c03\u4fa7\u8d70\u6c1f\u5229\u6602<br>\u2022 \u5236\u51b7\u5feb\uff0c\u51fa\u98ce7-18\u2103<br>\u2022 \u6807\u914dPE\u51c0\u5316+\u4e09\u7ba1\u5236\u9664\u6e7f<br>\u2022 \u9002\u5408\uff1a\u5bf9\u9664\u6e7f\u6709\u521a\u9700\u3001\u8ffd\u6c42\u5feb\u901f\u5236\u51b7<\/div>\n <div class=\"db-cc-price\" style=\"color:var(--db-blue)\">89,804\u5143<\/div>\n <\/div>\n <div class=\"db-cc db-cc-star\" style=\"border-color:var(--db-green)\">\n <span class=\"db-cc-badge\" style=\"background:var(--db-green-bg);color:var(--db-green)\">\u65b9\u6848B \u00b7 \u6c34\u5885\u9002<\/span>\n <div class=\"db-cc-title\">\u5929\u6c34\u5730\u6c34 \u4e24\u8054\u4f9b<\/div>\n <div class=\"db-cc-spec\">\u2022 \u7a7a\u8c03\u4fa7\u8d70\u6c34<br>\u2022 \u51fa\u98ce\u67d4\u548c\uff0c15-20\u2103<br>\u2022 \u5168\u53d8\u9891\uff0c\u4e00\u6b21\u7cfb\u7edf<br>\u2022 \u9002\u5408\uff1a\u5bb6\u6709\u8001\u4eba\u5c0f\u5b69\u3001\u6015\u51b7\u98ce\u76f4\u5439<\/div>\n <div class=\"db-cc-price\" style=\"color:var(--db-green)\">93,849\u5143<\/div>\n <\/div>\n<\/div>\n<div class=\"db-info\" style=\"background:var(--db-olive-bg)\">\n <span style=\"font-weight:500;color:var(--db-olive)\">\ud83d\udca1 \u9009\u62e9\u903b\u8f91\uff1a<\/span>\u4e24\u8005\u5404\u6709\u4f18\u52bf\uff0c\u6ca1\u6709\u7edd\u5bf9\u597d\u574f\uff0c\u53d6\u51b3\u4e8e\u60a8\u66f4\u770b\u91cd\u4ec0\u4e48\u2014\u2014<strong>\u63a7\u6e7f\u9664\u6e7f\u9009A\uff0c\u6781\u81f4\u8212\u9002\u65e0\u98ce\u611f\u9009B<\/strong>\u3002\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u4e24\u65b9\u6848\u6838\u5fc3\u5dee\u5f02<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u65b9\u6848A\uff1a\u51fa\u98ce7-18\u2103 \u9664\u6e7f\u5f3a<\/span><span class=\"db-tag db-tag-sep\">vs<\/span><span class=\"db-tag db-tag-green\">\u65b9\u6848B\uff1a\u51fa\u98ce15-20\u2103 \u65e0\u98ce\u611f<\/span><\/div>'},\n\n {num:3,title:'\u5185\u673a\u914d\u7f6e\u603b\u89c8',desc:'\u5404\u533a\u9009\u578b',color:'#0F6E56',bg:'rgba(15,110,86,0.08)',\n content:`\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>A\uff1a\u5c0a\u777f\u5168\u6548\u5185\u673a<\/th><th>B\uff1a\u6c34\u5885\u9002\u98ce\u76d8<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5ba2\u9910\u5385<\/td><td>75\u33a1<\/td><td>90(\u4e24\u7ba1)+32(\u4e24\u7ba1)<\/td><td>153+119<\/td><\/tr>\n <tr><td>\u4e3b\u53671<\/td><td>30\u33a1<\/td><td>56(\u4e09\u7ba1)<\/td><td>119<\/td><\/tr>\n <tr><td>\u4e3b\u53672<\/td><td>30\u33a1<\/td><td>56(\u4e09\u7ba1)<\/td><td>119<\/td><\/tr>\n <tr><td>\u6b21\u5367<\/td><td>14\u33a1<\/td><td>25(\u4e09\u7ba1)<\/td><td>34<\/td><\/tr>\n <tr><td><strong>\u5408\u8ba1<\/strong><\/td><td>150\u33a1<\/td><td class=\"db-hi-blue\"><strong>5\u53f0\uff08\u5176\u4e2d3\u53f0\u4e09\u7ba1\uff09<\/strong><\/td><td class=\"db-hi-green\"><strong>5\u53f0\u98ce\u76d8<\/strong><\/td><\/tr>\n <\/tbody>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u5185\u5916\u673a\u529f\u80fd\u8bf4\u660e<\/h4>\n<div class=\"db-commit-grid\">\n <div class=\"db-commit-card\">\n <p class=\"db-cch\" style=\"color:var(--db-blue)\">\u4e09\u7ba1\u5236\u5185\u673a\uff08\u65b9\u6848A\u5367\u5ba4\uff09<\/p>\n <p class=\"db-ccd\">\u53ef\u5b9e\u73b0\"\u9664\u6e7f\u4e0d\u964d\u6e29\"\u2014\u2014\u6210\u90fd\u6885\u96e8\u5b63\uff08\u6e7f\u5ea680%+\uff09\uff0c\u666e\u901a\u7a7a\u8c03\u9664\u6e7f\u4f34\u968f\u964d\u6e29\uff0c\u8d8a\u9664\u8d8a\u51b7\uff1b<strong>\u4e09\u7ba1\u5236\u56de\u6536\u4f59\u70ed\u518d\u52a0\u70ed\uff0c\u51fa\u98ce\u63a5\u8fd1\u5ba4\u6e29\uff0c\u4f53\u611f\u8212\u9002<\/strong>\u3002\u8fd9\u662f\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7684\u6838\u5fc3\u5dee\u5f02\u5316\u529f\u80fd\u3002<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\" style=\"color:var(--db-txt2)\">\u4e24\u7ba1\u5236\u5185\u673a\uff08\u65b9\u6848A\u5ba2\u5385\uff09<\/p>\n <p class=\"db-ccd\">\u5e38\u89c4\u5236\u51b7\/\u5236\u70ed\uff0c\u65e0\u72ec\u7acb\u9664\u6e7f\u529f\u80fd\uff0c\u9002\u5408\u5ba2\u9910\u5385\u7b49\u5bf9\u6e7f\u5ea6\u63a7\u5236\u8981\u6c42\u4e0d\u9ad8\u7684\u533a\u57df\u3002<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\" style=\"color:var(--db-green)\">\u6c34\u5885\u9002\u98ce\u76d8\uff08\u65b9\u6848B\uff09<\/p>\n <p class=\"db-ccd\">\u8d70\u6c34\u7cfb\u7edf\uff0c\u51fa\u98ce\u6e29\u5ea615-20\u2103\uff0c<strong>\u65e0\u5439\u98ce\u611f\uff0c\u9002\u5408\u957f\u65f6\u95f4\u505c\u7559\u533a\u57df<\/strong>\u3002\u96f6\u8d8a\u7cfb\u5217\u98ce\u76d8\u673a\u8eab\u4ec5192mm\u8d85\u8584\uff0c\u6700\u4f4e17dB\u9759\u97f3\uff0c\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u3002\u5168\u5c4b\u67d4\u548c\u9001\u98ce\uff0c\u8001\u4eba\u5c0f\u5b69\u5c24\u5176\u8212\u9002\u3002<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\" style=\"color:var(--db-amber)\">\u5730\u6696\u7cfb\u7edf\uff08\u4e24\u65b9\u6848\u5171\u6709\uff09<\/p>\n <p class=\"db-ccd\">169\u5143\/\u33a1 \u00d7 150\u33a1 = 25,350\u5143\u3002\u5730\u6696\u51fa\u6c34\u6e29\u5ea6\u5747\u5300\uff0c\u811a\u6696\u5934\u4e0d\u70ed\uff0c\u662f\u89e3\u51b3\"\u6015\u51b7\"\u6700\u5f7b\u5e95\u7684\u65b9\u6848\u3002<\/p>\n <\/div>\n<\/div>\n<div class=\"db-info\" style=\"background:var(--db-blue-bg)\">\n <span style=\"font-weight:500;color:var(--db-blue)\">\u8d85\u914d\u7387\u8bf4\u660e\uff1a<\/span>\u65b9\u6848A\u8d85\u914d\u7387129.5%\uff08\u5141\u8bb8\u533a\u95f4110%-130%\uff09\u2705 &nbsp;&nbsp; \u65b9\u6848B\u6c34\u7cfb\u7edf\u8fde\u63a5\u7387\u4e0d\u53d7\u9650\uff08\u53ef\u8d85200%\uff09\u2705\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u914d\u7f6e\u4eae\u70b9<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u65b9\u6848A\uff1a5\u53f0\u542b3\u53f0\u4e09\u7ba1\u5236<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-green\">\u65b9\u6848B\uff1a5\u53f0\u98ce\u76d8\u6c34\u7cfb\u7edf<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-amber\">\u5730\u6696\uff1a150\u33a1\u5168\u8986\u76d6<\/span><\/div>'},\n\n {num:4,title:'\u65b9\u6848A\uff1a\u5c0a\u777f\u5168\u6548',desc:'\u914d\u7f6e\u4e0e\u6838\u7b97',color:'#1D6BA8',bg:'rgba(29,107,168,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-blue-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-blue)\">\u65b9\u6848\u5b9a\u4f4d\uff1a<\/span>\u63a8\u8350\u578b\u65b9\u6848\u2014\u2014\u9002\u5408\u5bf9\u9664\u6e7f\u3001\u51c0\u5316\u3001\u5feb\u901f\u5236\u51b7\u6709\u8981\u6c42\u7684\u7528\u6237\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u7cfb\u7edf\u914d\u7f6e\u4e0e\u62a5\u4ef7<\/h4>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>8.5\u6298\u540e<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-200FSXPN5Q<\/td><td>25,863<\/td><td>21,984<\/td><td>600<\/td><td class=\"db-hi-blue\">22,584<\/td><\/tr>\n <tr><td>\u5185\u673a90(\u4e24\u7ba1)<\/td><td>RPIZ-90FSVNZQD\/P<\/td><td>5,988<\/td><td>5,090<\/td><td>1,600<\/td><td class=\"db-hi-blue\">6,690<\/td><\/tr>\n <tr><td>\u5185\u673a32(\u4e24\u7ba1)<\/td><td>RPIZ-32FSVNZ1QD\/PC<\/td><td>4,513<\/td><td>3,836<\/td><td>1,600<\/td><td class=\"db-hi-blue\">5,436<\/td><\/tr>\n <tr><td>\u5185\u673a56(\u4e09\u7ba1)\u00d72<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>11,326<\/td><td>9,627<\/td><td>3,800<\/td><td class=\"db-hi-blue\">13,427<\/td><\/tr>\n <tr><td>\u5185\u673a25(\u4e09\u7ba1)<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>5,050<\/td><td>4,293<\/td><td>1,900<\/td><td class=\"db-hi-blue\">6,193<\/td><\/tr>\n <tr><td>\u6c34\u6a21\u5757<\/td><td>RWMG-160FWXNZQ<\/td><td>8,375<\/td><td>7,119<\/td><td>625<\/td><td class=\"db-hi-blue\">7,744<\/td><\/tr>\n <tr><td>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td>PC-P1HPQA \u00d75<\/td><td>2,380<\/td><td>2,380<\/td><td>\u2014<\/td><td class=\"db-hi-blue\">2,380<\/td><\/tr>\n <tr><td colspan=\"5\" style=\"font-weight:500\">\u7a7a\u8c03\u5c0f\u8ba1<\/td><td class=\"db-hi-blue\" style=\"font-weight:500\">64,454<\/td><\/tr>\n <tr><td colspan=\"5\">\u5730\u6696\u7cfb\u7edf\uff08169\u5143\/\u33a1 \u00d7 150\u33a1\uff09<\/td><td class=\"db-hi-amber\" style=\"font-weight:500\">25,350<\/td><\/tr>\n <\/tbody>\n<\/table>\n<div class=\"db-price-box\">\n <span class=\"db-pb-label\">\u65b9\u6848A\u603b\u4ef7\uff08\u542b\u7a7a\u8c03+\u5730\u6696\uff09<\/span>\n <span class=\"db-pb-val\">89,804\u5143<\/span>\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin:16px 0 8px\">\ud83c\udfe0 \u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u00b7 \u6838\u5fc3\u6280\u672f\u8be6\u60c5<\/h4>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\" style=\"display:inline-flex;align-items:center;gap:4px;font-size:11px;color:var(--db-blue);text-decoration:none;margin-bottom:12px;padding:3px 8px;background:var(--db-blue-bg);border-radius:4px\">\ud83d\udd17 \u67e5\u770b\u5b98\u7f51\u4ea7\u54c1\u8be6\u60c5\u9875 \u2192<\/a>\n\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:8px;margin-bottom:12px\">\n <div style=\"background:var(--db-blue-bg);border-radius:var(--db-rad-sm);padding:10px 12px\">\n <p style=\"font-size:11px;font-weight:600;color:var(--db-blue);margin-bottom:6px\">\ud83c\udf21\ufe0f \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/p>\n <p style=\"font-size:11px;color:var(--db-txt2);line-height:1.6\">\u884c\u4e1a\u72ec\u6709\u300c\u667a\u611f\u4e09\u7ba1\u70ed\u56de\u6536\u6280\u672f\u300d\uff08\u4e13\u5229 ZL201410039143.3\uff09\u3002\u4e24\u7247\u6362\u70ed\u5668\u72ec\u7acb\u8fd0\u884c\uff1aA\u7247\u5236\u51b7\u9664\u6e7f\uff0cB\u7247\u56de\u6536\u4f59\u70ed\u518d\u70ed\u51fa\u98ce\uff0c\u51fa\u98ce\u6e29\u5ea6\u4fdd\u6301 <strong style=\"color:var(--db-blue)\">18\u2103<\/strong>\uff08\u666e\u901a\u7a7a\u8c03\u4ec512\u2103\uff09\u3002\u4e09\u5927\u6a21\u5f0f\uff1a\u964d\u6e29\u9664\u6e7f \/ \u4e0d\u964d\u6e29\u9664\u6e7f \/ \u5347\u6e29\u9664\u6e7f\uff08\u56de\u5357\u5929\u4e13\u5c5e\uff09<\/p>\n <\/div>\n <div style=\"background:var(--db-green-bg);border-radius:var(--db-rad-sm);padding:10px 12px\">\n <p style=\"font-size:11px;font-weight:600;color:var(--db-green);margin-bottom:6px\">\ud83d\udee1\ufe0f \u5168\u98ce\u8def\u51c0\u5316\u8231<\/p>\n <p style=\"font-size:11px;color:var(--db-txt2);line-height:1.6\">\u516d\u91cd\u51c0\u5316\uff1a\u6da1\u8f6e\u6291\u83cc\u2192\u8717\u58f3\u6291\u83cc\u2192\u63a5\u6c34\u76d8\u6291\u83cc\u2192\u7fc5\u7247\u81ea\u6e05\u6d01\u219260\u2103\u9ad8\u6e29\u6740\u83cc\u2192PE+\u51c0\u5316\u6a21\u5757\u3002\u4e0d\u53ea\u8fc7\u6ee4\u7a7a\u6c14\uff0c\u66f4\u51c0\u5316\u7a7a\u8c03\u672c\u8eab\u3002PM2.5\u53bb\u9664\u7387 <strong style=\"color:var(--db-green)\">\u226599%<\/strong>\uff0c\u7532\u919b \u226588.6%\uff0c\u7532\u6d41\u75c5\u6bd2 \u226599%<\/p>\n <\/div>\n <div style=\"background:rgba(83,74,183,0.07);border-radius:var(--db-rad-sm);padding:10px 12px\">\n <p style=\"font-size:11px;font-weight:600;color:#534AB7;margin-bottom:6px\">\ud83e\udd2b \u6781\u81f4\u9759\u97f3 17dB<\/p>\n <p style=\"font-size:11px;color:var(--db-txt2);line-height:1.6\">\u56db\u7ef4\u534f\u540c\u964d\u566a\uff1a\u30c0\u30dc\u5d4c\u5408\u5de5\u827a\uff08\u87ba\u9489\u51cf\u5c1175%\u51cf\u9707\uff09+ \u76f4\u6d41\u65e0\u5237\u7535\u673a + \u4e13\u5229\u51b7\u5a92\u788e\u6ce1\u6280\u672f + \u8717\u58f3\u6574\u6d41\u788e\u6da1\u9001\u98ce\u3002\u65b0\u5185\u673a\u6700\u4f4e\u6863\u4ec5 <strong style=\"color:#534AB7\">17dB(A)<\/strong>\uff0c\u4f4e\u4e8e\u6811\u53f6\u6c99\u6c99\u58f0\uff0820dB\uff09<\/p>\n <\/div>\n <div style=\"background:var(--db-amber-bg);border-radius:var(--db-rad-sm);padding:10px 12px\">\n <p style=\"font-size:11px;font-weight:600;color:var(--db-amber);margin-bottom:6px\">\u2744\ufe0f \u5bbd\u6e29\u57df\u7a33\u5b9a\u8fd0\u884c<\/p>\n <p style=\"font-size:11px;color:var(--db-txt2);line-height:1.6\">\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a\uff1a\u5236\u70ed <strong style=\"color:var(--db-amber)\">-25\u2103<\/strong> \u4f4e\u6e29\u5f3a\u70ed \/ \u5236\u51b7 60\u2103 \u4e0d\u505c\u673a\uff0cAPF\u6700\u9ad8 6.2\uff0c\u51ac\u5b63\u5236\u70ed\u91cf\u63d0\u534730%\u3002\u6210\u90fd\u6781\u7aef\u5929\u6c14\uff08\u96e8\u5939\u96ea\u3001\u6301\u7eed\u9634\u51b7\uff09\u7167\u5e38\u7a33\u5b9a\u8fd0\u884c<\/p>\n <\/div>\n<\/div>\n\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u6838\u5fc3\u53c2\u6570<\/th><th colspan=\"2\">\u672c\u65b9\u6848\u9009\u914d\uff08RAS-200FSXPN5Q\uff09<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5236\u51b7\u91cf \/ \u5236\u70ed\u91cf<\/td><td colspan=\"2\">20.0 kW \/ 22.4 kW<\/td><\/tr>\n <tr><td>APF\u80fd\u6548<\/td><td colspan=\"2\">5.45<\/td><\/tr>\n <tr><td>\u6700\u5927\u65e5\u9664\u6e7f\u91cf<\/td><td colspan=\"2\">175L\uff08\u76f8\u5f53\u4e8e\u4e00\u6574\u6d74\u7f38\u6c34\u6c7d\uff09<\/td><\/tr>\n <tr><td>\u6e7f\u5ea6\u8c03\u8282\u8303\u56f4<\/td><td colspan=\"2\">35%~90% RH\uff0c\u7cbe\u5ea61%\uff0c56\u6863\u7cbe\u51c6\u8c03\u8282<\/td><\/tr>\n <tr><td>\u8fd0\u884c\u6e29\u5ea6\u8303\u56f4<\/td><td colspan=\"2\">\u5236\u51b7 -5\u2103~60\u2103 \/ \u5236\u70ed -25\u2103~43\u2103<\/td><\/tr>\n <tr><td>\u566a\u97f3\uff08\u65b0\u5185\u673a\uff09<\/td><td colspan=\"2\">\u6700\u4f4e 17dB(A)<\/td><\/tr>\n <tr><td>\u538b\u7f29\u673a\u7c7b\u578b<\/td><td colspan=\"2\">\u6da1\u65cb\u8865\u6c14\u589e\u7113\uff08200\u578b\u4ee5\u4e0a\uff09<\/td><\/tr>\n <tr><td>\u667a\u63a7<\/td><td colspan=\"2\">\u6807\u914d5G\u7269\u8054\u7f51\u6a21\u5757\uff0c\u300c\u65e5\u7acb\u667a\u5bb6\u300dAPP\uff0c\u652f\u6301OTA\u5347\u7ea7<\/td><\/tr>\n <tr><td>\u5b98\u65b9\u8d28\u4fdd<\/td><td colspan=\"2\">\u6574\u673a5\u5e74 \/ \u538b\u7f29\u673a6\u5e74\uff1b\u5165\u4f1a\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr>\n <\/tbody>\n<\/table>\n\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\ud83d\udcca \u6280\u672f\u6838\u7b97<\/h4>\n<table>\n <thead><tr><th>\u6838\u7b97\u9879<\/th><th>\u8ba1\u7b97<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5185\u673a\u603b\u51b7\u91cf<\/td><td>9.0+3.2+5.6\u00d72+2.5 = 25.9kW<\/td><td>\u2014<\/td><\/tr>\n <tr><td>\u5916\u673a\u5236\u51b7\u91cf<\/td><td>20.0kW<\/td><td>\u2014<\/td><\/tr>\n <tr><td>\u8d85\u914d\u7387<\/td><td>25.9\u00f720.0\u00d7100% = 129.5%<\/td><td class=\"db-hi-green\">\u2705 \u5141\u8bb8\u533a\u95f4\uff08110%-130%\uff09<\/td><\/tr>\n <tr><td>\u70ed\u8d1f\u8377\u5339\u914d<\/td><td>150\u33a1\u00d7100-120W\/\u33a1 = 15-18kW\uff1b\u5916\u673a\u5236\u70ed22.4kW<\/td><td class=\"db-hi-green\">\u2705 \u6ee1\u8db3\u6700\u51b7\u5929\u9700\u6c42<\/td><\/tr>\n <\/tbody>\n<\/table>`,\n rec:'<div class=\"db-recbar-title\">\u65b9\u6848A\u6838\u5fc3\u4f18\u52bf<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">PE\u51c0\u5316 PM2.5\u53bb\u966499%<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-green\">\u4e09\u7ba1\u5236\u9664\u6e7f\u4e0d\u964d\u6e29<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-amber\">89,804\u5143 \u5168\u5305<\/span><\/div>'},\n\n {num:5,title:'\u65b9\u6848B\uff1a\u6c34\u5885\u9002',desc:'\u914d\u7f6e\u4e0e\u6838\u7b97',color:'#0F6E56',bg:'rgba(15,110,86,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-green-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-green)\">\u65b9\u6848\u5b9a\u4f4d\uff1a<\/span>\u9ad8\u914d\u578b\u65b9\u6848\u2014\u2014\u9002\u5408\u6015\u51b7\u98ce\u76f4\u5439\u3001\u8ffd\u6c42\u6781\u81f4\u8212\u9002\u7684\u7528\u6237\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u7cfb\u7edf\u914d\u7f6e\u4e0e\u62a5\u4ef7<\/h4>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u6263\u540e<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-180FPUEN2Q\/M<\/td><td>30,110<\/td><td>25,594<\/td><td>3,600<\/td><td class=\"db-hi-green\">29,194<\/td><\/tr>\n <tr><td>\u98ce\u76d8153<\/td><td>RFP-153WAR\/DBT12Y03\/P<\/td><td>4,930<\/td><td>4,930<\/td><td>3,800<\/td><td class=\"db-hi-green\">8,730<\/td><\/tr>\n <tr><td>\u98ce\u76d8119\u00d73<\/td><td>RFP-119WAR\/DBT12Y03\/P<\/td><td>10,500<\/td><td>10,500<\/td><td>11,400<\/td><td class=\"db-hi-green\">21,900<\/td><\/tr>\n <tr><td>\u98ce\u76d834<\/td><td>RFP-34WAR\/DBT12Y03\/P<\/td><td>2,625<\/td><td>2,625<\/td><td>3,800<\/td><td class=\"db-hi-green\">6,425<\/td><\/tr>\n <tr><td>\u7ebf\u63a7\u5668<\/td><td>SXC-TD01 \u00d75<\/td><td>1,875<\/td><td>1,875<\/td><td>\u2014<\/td><td class=\"db-hi-green\">1,875<\/td><\/tr>\n <tr><td>\u6c34\u6e29\u63a7\u5236\u5668<\/td><td>SXC-TE01<\/td><td>375<\/td><td>375<\/td><td>\u2014<\/td><td class=\"db-hi-green\">375<\/td><\/tr>\n <tr><td colspan=\"5\" style=\"font-weight:500\">\u7a7a\u8c03\u5c0f\u8ba1<\/td><td class=\"db-hi-green\" style=\"font-weight:500\">68,499<\/td><\/tr>\n <tr><td colspan=\"5\">\u5730\u6696\u7cfb\u7edf\uff08169\u5143\/\u33a1 \u00d7 150\u33a1\uff09<\/td><td class=\"db-hi-amber\" style=\"font-weight:500\">25,350<\/td><\/tr>\n <\/tbody>\n<\/table>\n<div class=\"db-price-box\" style=\"background:var(--db-green-bg);border-color:var(--db-green-bd)\">\n <span class=\"db-pb-label\">\u65b9\u6848B\u603b\u4ef7\uff08\u542b\u7a7a\u8c03+\u5730\u6696\uff09<\/span>\n <span class=\"db-pb-val\" style=\"color:var(--db-green)\">93,849\u5143<\/span>\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u6280\u672f\u8def\u5f84<\/h4>\n<table>\n <thead><tr><th>\u6280\u672f\u9879<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u7cfb\u7edf\u8def\u5f84<\/td><td>\u5929\u6c34\u5730\u6c34 + \u4e00\u6b21\u7cfb\u7edf\uff08\u4e3b\u673a\u53d8\u9891\u6cf5\u76f4\u8fde\u672b\u7aef\uff0c\u65e0\u7f13\u51b2\u6c34\u7bb1\uff09<\/td><\/tr>\n <tr><td>\u6c34\u7cfb\u7edf\u8fde\u63a5\u7387<\/td><td class=\"db-hi-green\">\u6c34\u7cfb\u7edf\u4e0d\u53d7\u9650\uff0c\u53ef\u8d85200% \u2705<\/td><\/tr>\n <tr><td>\u5916\u673a\u80fd\u529b<\/td><td>180\u5916\u673a\u5236\u51b718kW\/\u5236\u70ed20kW\uff0c\u5339\u914d150\u33a1\u70ed\u8d1f\u8377\uff0815-18kW\uff09\u2705<\/td><\/tr>\n <tr><td>\u53d8\u9891\u4f18\u52bf<\/td><td>\u5168\u53d8\u9891\uff08\u538b\u7f29\u673a+\u6c34\u6cf5+\u98ce\u673a\uff09\uff0c\u4f4e\u9891\u8fd0\u884c\u53ef\u964d\u81f33-5kW\uff0c\u907f\u514d\u9891\u7e41\u542f\u505c<\/td><\/tr>\n <\/tbody>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin:16px 0 8px\">\ud83d\udca7 \u65e5\u7acb\u6c34\u5885\u9002 \u00b7 \u6838\u5fc3\u6280\u672f\u8be6\u60c5<\/h4>\n<div class=\"db-commit-grid\" style=\"margin-bottom:12px\">\n <div class=\"db-commit-card\" style=\"border-left:3px solid var(--db-green)\">\n <p class=\"db-cch\" style=\"color:var(--db-green)\">\u8865\u6c14\u589e\u7113 \u00b7 -30\u2103\u5f3a\u70ed<\/p>\n <p class=\"db-ccd\">\u51c6\u4e8c\u7ea7\u538b\u7f29\uff0c\u4e2d\u95f4\u8865\u6c14\u589e\u7113\uff0c\u51b7\u5a92\u5faa\u73af\u91cf\u589e\u52a030%\uff0c\u5236\u70ed\u8fd0\u884c\u6e29\u5ea6\u4f4e\u81f3 <strong>-30\u2103<\/strong>\u3002\u914d\u5408PTT\u667a\u80fd\u9664\u971c\uff08\u9664\u971c\u6b21\u6570\u51cf\u5c112\/3\uff09\uff0c\u51ac\u5b63\u5236\u70ed\u80fd\u529b\u65e0\u8870\u51cf\u3002<\/p>\n <\/div>\n <div class=\"db-commit-card\" style=\"border-left:3px solid var(--db-blue)\">\n <p class=\"db-cch\" style=\"color:var(--db-blue)\">\u5168\u53d8\u9891\u8054\u52a8 \u00b7 \u4e00\u6b21\u7cfb\u7edf<\/p>\n <p class=\"db-ccd\">\u538b\u7f29\u673a+\u6c34\u6cf5+\u98ce\u673a<strong>\u5168\u76f4\u6d41\u53d8\u9891<\/strong>\uff0cCS\u667a\u80fd\u53d8\u9891\u5668\uff08\u65b0\u5e72\u7ebf\u540c\u6b3e\u6280\u672f\uff09\u5b9e\u65f6\u8c03\u8282\u3002\u4e00\u6b21\u7cfb\u7edf\u67b6\u6784\uff0c\u65e0\u53cd\u51b2\u6c34\u7bb1\uff0c\u53d8\u9891\u6cf5\u529f\u8017\u6700\u5927\u4e0b\u964d40%\u3002180\u5916\u673a\u4f4e\u9891\u53ef\u964d\u81f33-5kW\uff0c\u675c\u7edd\u9891\u7e41\u542f\u505c\u3002<\/p>\n <\/div>\n <div class=\"db-commit-card\" style=\"border-left:3px solid var(--db-purple)\">\n <p class=\"db-cch\" style=\"color:var(--db-purple)\">\u51fa\u98ce\u67d4\u548c \u00b7 \u65e0\u98ce\u611f\u4f53\u9a8c<\/p>\n <p class=\"db-ccd\">\u98ce\u76d8\u51fa\u6c34\u6e29\u5ea67-12\u2103\uff0c\u9001\u98ce\u6e29\u5ea6<strong>15-20\u2103<\/strong>\uff08\u6c1f\u7cfb\u7edf7-12\u2103\uff09\uff0c\u6e29\u5dee\u8d8a\u5c0f\u4f53\u611f\u8d8a\u8212\u9002\u3002\u96f6\u8d8a\u98ce\u76d8\u6700\u4f4e<strong>17dB(A)<\/strong>\uff0c\u652f\u63013D\u51fa\u98ce\u53e3\uff0c\u5168\u5c4b\u65e0\u6b7b\u89d2\u9001\u98ce\u3002<\/p>\n <\/div>\n <div class=\"db-commit-card\" style=\"border-left:3px solid var(--db-amber)\">\n <p class=\"db-cch\" style=\"color:var(--db-amber)\">\u4e94\u91cd\u9632\u51bb \u00b7 \u5168\u5e74\u65e0\u5fe7<\/p>\n <p class=\"db-ccd\">\u7535\u52a0\u70ed\u5e26 + PTT\u667a\u80fd\u9664\u971c + \u6c34\u6d41\u76d1\u63a7 + \u4e3b\u673a\u4f4e\u6e29\u81ea\u542f + \u77ed\u4fe1\u9884\u8b66\uff0c<strong>\u4e94\u91cd\u9632\u51bb\u4fdd\u62a4<\/strong>\u3002\u5236\u51b7\u8fd0\u884c\u6e29\u5ea6-5~48\u2103\uff0c\u5236\u70ed-30~28\u2103\uff0c\u6781\u7aef\u5929\u6c14\u65e0\u60e7\u3002<\/p>\n <\/div>\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u672c\u65b9\u6848\u5339\u914d \u00b7 RAS-180FPUEN2Q\/M \u53c2\u6570<\/h4>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th style=\"width:140px\">\u53c2\u6570\u9879<\/th><th>\u672c\u673a\u6570\u636e<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u51b7\/\u70ed\u91cf<\/td><td>16.0kW \/ 18.0kW<\/td><td>\u5339\u914d150\u33a1\u70ed\u8d1f\u837715-18kW<\/td><\/tr>\n <tr><td>COP \/ APF<\/td><td>3.30 \/ 3.20<\/td><td>\u4e00\u7ea7\u80fd\u6548<\/td><\/tr>\n <tr><td>\u5236\u51b7\u529f\u7387<\/td><td>5.42kW<\/td><td>220V\u5bb6\u7528\u7535\uff0c\u65e0\u9700380V<\/td><\/tr>\n <tr><td>\u5236\u70ed\u529f\u7387<\/td><td>5.45kW<\/td><td>\u5168\u76f4\u6d41\u53d8\u9891\uff0c\u4f4e\u9891\u53ef\u964d\u81f33-5kW<\/td><\/tr>\n <tr><td>\u566a\u97f3<\/td><td>57dB(A)<\/td><td>\u5916\u673a\u5c3a\u5bf8 1380\u00d7950\u00d7320mm<\/td><\/tr>\n <tr><td>\u51fa\u6c34\u6e29\u5ea6<\/td><td>\u5236\u51b75-25\u2103 \/ \u5236\u70ed25-55\u2103<\/td><td>\u5bbd\u57df\u53ef\u8c03<\/td><\/tr>\n <tr><td>\u8d28\u4fdd<\/td><td>\u5165\u4f1a\u5458\u5ef6\u4fdd\u81f310\u5e74<\/td><td>\u8fdc\u8d85\u884c\u4e1a3\u5e74\u6807\u51c6<\/td><\/tr>\n <\/tbody>\n<\/table>\n<p style=\"font-size:11px;color:var(--db-txt3);margin-top:4px\">\ud83d\udcce \u4ea7\u54c1\u6765\u6e90\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\" style=\"color:var(--db-blue)\">\u9f99\u8109\u6696\u901a\u5b98\u7f51 \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\u4ea7\u54c1\u8be6\u60c5<\/a><\/p>`,\n rec:'<div class=\"db-recbar-title\">\u65b9\u6848B\u6838\u5fc3\u4f18\u52bf<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-green\">\u51fa\u98ce15-20\u2103 \u65e0\u5439\u98ce\u611f<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-blue\">\u5168\u53d8\u9891 \u4f4e\u80fd\u8017<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-amber\">93,849\u5143 \u5168\u5305<\/span><\/div>'},\n\n {num:6,title:'\u516d\u7ef4\u5ea6\u5bf9\u6bd4',desc:'\u4e24\u65b9\u6848\u7efc\u5408\u6bd4\u8f83',color:'#534AB7',bg:'rgba(83,74,183,0.08)',\n content:`\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u65b9\u6848A\uff1a\u5c0a\u777f\u5168\u6548<\/th><th>\u65b9\u6848B\uff1a\u6c34\u5885\u9002<\/th><th>\u4f18\u52bf\u65b9<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u521d\u6295\u8d44<\/td><td class=\"db-hi-blue\">89,804\u5143<\/td><td>93,849\u5143<\/td><td class=\"db-hi-blue\">\u65b9\u6848A\uff08\u77014,045\u5143\uff09<\/td><\/tr>\n <tr><td>\u8fd0\u884c\u8d39<\/td><td>\u7ea63,600\u5143\/\u5e74<\/td><td>\u7ea63,600\u5143\/\u5e74<\/td><td>\u6301\u5e73<\/td><\/tr>\n <tr><td>\u8212\u9002\u5ea6<\/td><td>\u51fa\u98ce7-18\u2103\uff0c\u9664\u6e7f\u5f3a<\/td><td class=\"db-hi-green\">\u51fa\u98ce15-20\u2103\uff0c\u65e0\u98ce\u611f<\/td><td>\u65b9\u6848A\u63a7\u6e7f\u66f4\u5f3a \/ \u65b9\u6848B\u66f4\u67d4\u548c<\/td><\/tr>\n <tr><td>\u7a33\u5b9a\u6027<\/td><td>\u65e5\u7acb\u81ea\u7814\u538b\u7f29\u673a\uff0c\u6280\u672f\u6210\u719f<\/td><td>\u65e5\u7acb\u5168\u53d8\u9891\uff0c\u4e00\u6b21\u7cfb\u7edf<\/td><td>\u6301\u5e73<\/td><\/tr>\n <tr><td>\u7ef4\u62a4\u8d39<\/td><td>\u6807\u914d\u6c34\u6cf5\uff0c\u65e0\u989d\u5916\u9009\u914d<\/td><td>\u6807\u914d\u6c34\u6cf5\uff0c\u65e0\u989d\u5916\u9009\u914d<\/td><td>\u6301\u5e73<\/td><\/tr>\n <tr><td>\u5bff\u547d<\/td><td>\u5165\u4f1a\u5ef6\u4fdd\u81f310\u5e74<\/td><td>\u5165\u4f1a\u5ef6\u4fdd\u81f310\u5e74<\/td><td>\u6301\u5e73<\/td><\/tr>\n <\/tbody>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">20\u5e74\u603b\u6295\u5165\u6d4b\u7b97<\/h4>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u8ba1\u7b97\u9879<\/th><th>\u65b9\u6848A<\/th><th>\u65b9\u6848B<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u521d\u6295\u8d44<\/td><td>89,804\u5143<\/td><td>93,849\u5143<\/td><\/tr>\n <tr><td>\u5e74\u8fd0\u884c\u8d39<\/td><td>3,600\u5143\/\u5e74<\/td><td>3,600\u5143\/\u5e74<\/td><\/tr>\n <tr><td>20\u5e74\u8fd0\u884c\u8d39<\/td><td>72,000\u5143<\/td><td>72,000\u5143<\/td><\/tr>\n <tr><td>\u8bbe\u5907\u66f4\u6362\u8d39\uff08\u7b2c10\u5e74\uff09<\/td><td>0\u5143\uff08\u5ef6\u4fdd\u671f\u5185\uff09<\/td><td>0\u5143\uff08\u5ef6\u4fdd\u671f\u5185\uff09<\/td><\/tr>\n <tr><td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td><td class=\"db-hi-blue\"><strong>161,804\u5143<\/strong><\/td><td class=\"db-hi-green\"><strong>165,849\u5143<\/strong><\/td><\/tr>\n <\/tbody>\n<\/table>\n<div class=\"db-info\" style=\"background:var(--db-purple-bg)\">\n <span style=\"font-weight:500;color:var(--db-purple)\">\ud83d\udd0d AI\u9a8c\u8bc1\u5efa\u8bae\uff1a<\/span>\u60a8\u53ef\u4ee5\u5c06\u672c\u65b9\u6848\u53c2\u6570\u590d\u5236\u7ed9\u8c46\u5305\u3001DeepSeek\u7b49AI\uff0c\u9a8c\u8bc1\u8d85\u914d\u7387(129.5%)\u3001\u70ed\u8d1f\u8377\u5339\u914d\u3001PE\u51c0\u5316\u6548\u679c\u7b49\u662f\u5426\u5408\u7406\u3002\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">20\u5e74\u603b\u8d26<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u65b9\u6848A\uff1a161,804\u5143<\/span><span class=\"db-tag db-tag-sep\">vs<\/span><span class=\"db-tag db-tag-green\">\u65b9\u6848B\uff1a165,849\u5143<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-amber\">\u5dee\u8ddd4,045\u5143<\/span><\/div>'},\n\n {num:7,title:'\u8d28\u4fdd\u4e0e\u4f1a\u5458\u6743\u76ca',desc:'10\u5e74\u4fdd\u969c\u4f53\u7cfb',color:'#A32D2D',bg:'rgba(163,45,45,0.08)',\n content:`\n<div class=\"db-commit-grid\">\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udee1\ufe0f \u8d28\u4fdd\u653f\u7b56<\/p>\n <p class=\"db-ccd\">\u5165\u4f1a\u540e\u5bf9\u5e94\u7cfb\u5217\u5ef6\u4fdd\u81f310\u5e74\uff0c\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6\uff08\u884c\u4e1a\u4e00\u822c\u4e3a3\u5e74\uff09<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udccb \u589e\u9879\u627f\u8bfa<\/p>\n <p class=\"db-ccd\">\u5408\u540c\u5217\u660e\u5168\u90e8\u6750\u6599\u54c1\u724c\u89c4\u683c\uff0c\u65e0\u9690\u85cf\u8d39\u7528\u3002\u6240\u6709\u8f85\u6750\u6e05\u5355\u5728\u7b7e\u7ea6\u524d\u7531\u60a8\u786e\u8ba4<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udcde \u552e\u540e\u54cd\u5e94<\/p>\n <p class=\"db-ccd\">24h\u54cd\u5e94\uff0c\u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8\uff0c\u4f1a\u5458\u4f18\u5148\u6d3e\u5355\uff0c\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u5904\u7406<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udcb0 \u9000\u6b3e\u89c4\u5219<\/p>\n <p class=\"db-ccd\">\u7b7e\u7ea6\u540e\u4efb\u610f\u65f6\u95f4\u4e0d\u60f3\u505a\uff1a199\u5143\u5168\u989d\u9000 \/ \u4ea4\u4ed8\u4e0d\u6ee1\u610f\uff1a199\u5143\u5168\u989d\u9000\u6216\u62b5\u8bbe\u5907\u6b3e \/ \u6ee1\u610f\u52a0\u5165\u4f1a\u5458\uff1a\u8f6c\u4e3a\u7b2c1\u5e74\u4f1a\u8d39<\/p>\n <\/div>\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u4f1a\u5458\u6743\u76ca\u6e05\u5355\uff08199\u5143\/\u5e74\uff09<\/h4>\n<table>\n <thead><tr><th>\u6743\u76ca<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u6696\u901a\u91d1\u989d<\/td><td class=\"db-hi-blue\">\u7b7e\u7ea6\u5373\u90011000\u5143\uff0c\u53ef\u62b5\u62635\u5e74\u4f1a\u5458\u8d39(995\u5143)\u3001\u8bbe\u5907\u6b3e\u3001\u5b89\u88c5\u8d39<\/td><\/tr>\n <tr><td>\u670d\u52a1\u6298\u6263<\/td><td>\u6ee4\u82af5\u6298\uff0c\u6e05\u6d176\u6298\uff0c\u7ef4\u4fee8\u6298<\/td><\/tr>\n <tr><td>\u7cfb\u7edf\u5f02\u5e38<\/td><td class=\"db-hi-green\">\u4e0d\u9650\u6b21\u6570\u514d\u8d39\u4e0a\u95e8<\/td><\/tr>\n <tr><td>\u9690\u853d\u5de5\u7a0b\u5ef6\u4fdd<\/td><td>\u4f1a\u5458\u5ef6\u4fdd\u81f35\u5e74\uff08\u975e\u4f1a\u54582\u5e74\uff09<\/td><\/tr>\n <tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td class=\"db-hi-green\">\u5165\u4f1a\u540e\u5ef6\u4fdd\u81f310\u5e74\uff08\u975e\u4f1a\u54585\u5e74\uff09<\/td><\/tr>\n <tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/td><\/tr>\n <tr><td>\u5e74\u5ea6\u68c0\u6d4b<\/td><td>\u6bcf\u5e74\u514d\u8d39\u7cfb\u7edf\u68c0\u6d4b\u4e00\u6b21<\/td><\/tr>\n <tr><td>\u7ef4\u4fdd\u63d0\u9192<\/td><td>\u6ee4\u82af\u66f4\u6362\u3001\u9505\u7089\u6e05\u6d17\u3001\u7cfb\u7edf\u4fdd\u517b\u4e3b\u52a8\u63d0\u9192<\/td><\/tr>\n <\/tbody>\n<\/table>`,\n rec:'<div class=\"db-recbar-title\">\u4fdd\u969c\u4eae\u70b9<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-green\">10\u5e74\u5ef6\u4fdd<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-blue\">1000\u5143\u6696\u901a\u91d1\u989d<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-red\">24h\u54cd\u5e94<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-amber\">199\u5143\/\u5e74<\/span><\/div>'}\n],\n\n\/* \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500 \u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1 \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500 *\/\n2:[\n {num:1,title:'\u8bbe\u8ba1\u4f9d\u636e',desc:'\u89c4\u8303\u4e0e\u6807\u51c6',color:'#1D6BA8',bg:'rgba(29,107,168,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-blue-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-blue)\">\ud83d\udccb \u672c\u9879\u76ee\u5730\u5740\uff1a<\/span>\u6210\u90fd\u5e02\uff08\u5f85\u586b\u5199\uff09\u00b7 150\u33a1 \u5168\u5c4b\u8212\u9002\u7cfb\u7edf\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u8bbe\u8ba1\u6807\u51c6<\/h4>\n<table style=\"margin-bottom:12px\">\n <tr><th>\u8bbe\u8ba1\u4f9d\u636e<\/th><th>\u6807\u51c6\u7f16\u53f7<\/th><\/tr>\n <tr><td>\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><td>GB 50736-2012<\/td><\/tr>\n <tr><td>\u5730\u9762\u8f90\u5c04\u4f9b\u6696\u6280\u672f\u89c4\u7a0b<\/td><td>JGJ 142-2012<\/td><\/tr>\n <tr><td>\u51b7\u8d1f\u8377\u8bbe\u8ba1\u53c2\u8003<\/td><td>\u300a\u5b9e\u7528\u4f9b\u70ed\u7a7a\u8c03\u8bbe\u8ba1\u624b\u518c\u300b<\/td><\/tr>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u5ba4\u5185\u8bbe\u8ba1\u53c2\u6570<\/h4>\n<table style=\"margin-bottom:12px\">\n <tr><th>\u5b63\u8282<\/th><th>\u8bbe\u8ba1\u6e29\u5ea6<\/th><th>\u8bbe\u8ba1\u6e7f\u5ea6<\/th><\/tr>\n <tr><td>\u590f\u5b63<\/td><td class=\"db-hi-blue\">24~26\u2103<\/td><td>40%~60%<\/td><\/tr>\n <tr><td>\u51ac\u5b63<\/td><td class=\"db-hi-amber\">18~22\u2103<\/td><td>\u65e0\u89c4\u5b9a<\/td><\/tr>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u91c7\u6696\u70ed\u8d1f\u8377\u8bbe\u8ba1<\/h4>\n<table>\n <tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u8bf4\u660e<\/th><\/tr>\n <tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>150\u33a1<\/td><td>\u5168\u5c4b\u5730\u6696\u8986\u76d6<\/td><\/tr>\n <tr><td>\u8bbe\u8ba1\u70ed\u8d1f\u8377\u6307\u6807<\/td><td>100-120 W\/\u33a1<\/td><td>GB 50736-2012 \u6210\u90fd\u5730\u533a\u9ad8\u5c42<\/td><\/tr>\n <tr><td>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/td><td class=\"db-hi-amber\">15-18kW<\/td><td>\u6700\u51b7\u5929\u9700\u6c42<\/td><\/tr>\n <tr><td>\u5916\u673a\u5236\u70ed\u91cf<\/td><td>22.4kW\uff08\u5236\u51b720kW\uff09<\/td><td class=\"db-hi-green\">\u2705 \u6ee1\u8db315-18kW\u91c7\u6696\u9700\u6c42<\/td><\/tr>\n<\/table>`,\n rec:'<div class=\"db-recbar-title\">\u8bbe\u8ba1\u6838\u5fc3\u6307\u6807<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">GB50736-2012<\/span><span class=\"db-tag db-tag-amber\">\u70ed\u8d1f\u837715-18kW<\/span><span class=\"db-tag db-tag-green\">\u5730\u6696169\u5143\/\u33a1<\/span><span class=\"db-tag db-tag-purple\">150\u33a1\u5168\u8986\u76d6<\/span><\/div>'},\n\n {num:2,title:'\u914d\u7f6e\u6e05\u5355',desc:'\u7a7a\u8c03+\u5730\u6696\u914d\u7f6e',color:'#BA7517',bg:'rgba(186,117,23,0.08)',\n content:`\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u65b9\u6848A \u7a7a\u8c03\u914d\u7f6e\uff08\u5c0a\u777f\u5168\u6548\uff09<\/h4>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u7c7b\u578b<\/th><th>\u51b7\u91cf<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5ba2\u9910\u5385<\/td><td>75\u33a1<\/td><td>RPIZ-90FSVNZQD\/P<\/td><td>\u4e24\u7ba1\u5236<\/td><td>9.0kW<\/td><\/tr>\n <tr><td>\u5ba2\u9910\u5385<\/td><td>75\u33a1<\/td><td>RPIZ-32FSVNZ1QD\/PC<\/td><td>\u4e24\u7ba1\u5236<\/td><td>3.2kW<\/td><\/tr>\n <tr><td>\u4e3b\u53671<\/td><td>30\u33a1<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>\u4e09\u7ba1\u5236<\/td><td>5.6kW<\/td><\/tr>\n <tr><td>\u4e3b\u53672<\/td><td>30\u33a1<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>\u4e09\u7ba1\u5236<\/td><td>5.6kW<\/td><\/tr>\n <tr><td>\u6b21\u5367<\/td><td>14\u33a1<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>\u4e09\u7ba1\u5236<\/td><td>2.5kW<\/td><\/tr>\n <tr><td><strong>\u5408\u8ba1<\/strong><\/td><td>150\u33a1<\/td><td><strong>5\u53f0<\/strong><\/td><td><strong>3\u4e09\u7ba1+2\u4e24\u7ba1<\/strong><\/td><td><strong>25.9kW<\/strong><\/td><\/tr>\n <\/tbody>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u5730\u6696\u914d\u7f6e<\/h4>\n<table>\n <thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u6807\u51c6<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u8986\u76d6\u9762\u79ef<\/td><td>150\u33a1 \u5168\u5c4b<\/td><td>\u5ba2\u9910\u538575\u33a1 + \u4e3b\u53671(30\u33a1) + \u4e3b\u53672(30\u33a1) + \u6b21\u5367(14\u33a1)<\/td><\/tr>\n <tr><td>\u5730\u6696\u7ba1\u6750<\/td><td>PE-RT \u00d820mm<\/td><td>JGJ 142-2012 \u6807\u51c6<\/td><\/tr>\n <tr><td>\u76d8\u7ba1\u95f4\u8ddd<\/td><td>200mm<\/td><td>\u2014<\/td><\/tr>\n <tr><td>\u8bbe\u8ba1\u6c34\u6e29<\/td><td>\u4f9b\u6c3435-45\u2103<\/td><td>GB 50736-2012 \u5730\u8868\u226429\u2103<\/td><\/tr>\n <tr><td>\u5355\u4ef7<\/td><td class=\"db-hi-amber\">169\u5143\/\u33a1<\/td><td>\u542b\u5206\u96c6\u6c34\u5668\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u56de\u586b<\/td><\/tr>\n <tr><td>\u5730\u6696\u5c0f\u8ba1<\/td><td class=\"db-hi-amber\"><strong>25,350\u5143<\/strong><\/td><td>169\u5143\/\u33a1 \u00d7 150\u33a1<\/td><\/tr>\n <\/tbody>\n<\/table>\n<div style=\"display:grid;grid-template-columns:1fr 1fr 1fr;gap:8px;margin-top:12px\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-01.jpg\" alt=\"\u8bbe\u5907\u6e05\u535501\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-02.jpg\" alt=\"\u8bbe\u5907\u6e05\u535502\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-03.jpg\" alt=\"\u8bbe\u5907\u6e05\u535503\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-04.jpg\" alt=\"\u8bbe\u5907\u6e05\u535504\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-05.jpg\" alt=\"\u8bbe\u5907\u6e05\u535505\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-06.jpg\" alt=\"\u8bbe\u5907\u6e05\u535506\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-07.jpg\" alt=\"\u8bbe\u5907\u6e05\u535507\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u914d\u7f6e\u901f\u89c8<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u65b9\u6848A\uff1a5\u53f0 25.9kW<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-amber\">\u5730\u6696\uff1a150\u33a1 25,350\u5143<\/span><span class=\"db-tag db-tag-sep\"><\/span><span class=\"db-tag db-tag-green\">\u76d8\u7ba1\u00d820mm \u95f4\u8ddd200mm<\/span><\/div>'},\n {num:3,title:'\u65bd\u5de5\u6d41\u7a0b',desc:'\u516d\u6b65\u7cbe\u5de5\u6807\u51c6',color:'#639922',bg:'rgba(99,153,34,0.08)',\n content:`\n<div class=\"db-timeline\">\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-blue)\">1<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/p>\n <p class=\"db-tl-d\">\u5de5\u957f\u5230\u573a\uff0c\u786e\u8ba4\u5185\u5916\u673a\u5b89\u88c5\u4f4d\u7f6e\u3001\u94dc\u7ba1\u8d70\u5411\u3001\u540a\u9876\u7a7a\u95f4\u3001\u5730\u6696\u5206\u533a\u8def\u7531\u3001\u5f00\u5b54\u70b9\u4f4d\uff0c\u62cd\u6444\u73b0\u573a\u7167\u7247\u5b58\u6863<\/p>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-green)\">2<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u7b2c\u4e8c\u6b65\uff1a\u8bbe\u8ba1\u51fa\u56fe<\/p>\n <p class=\"db-tl-d\">\u51fa\u5e73\u9762\u5e03\u7f6e\u56fe\uff08\u7a7a\u8c03+\u5730\u6696\uff09\u3001\u94dc\u7ba1\/\u6c34\u7ba1\u8d70\u5411\u56fe\u3001\u9001\u56de\u98ce\u53e3\u5c3a\u5bf8\u56fe\u3001\u5730\u6696\u5206\u533a\u793a\u610f\u56fe\uff0c\u63d0\u4f9b\u7ed9\u6728\u5de5\u548c\u74e6\u5de5\u5f00\u5b54\u53c2\u8003<\/p>\n <div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:8px;margin-top:10px\">\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-erliangongxitongshejitu01.png\" alt=\"\u4e8c\u8054\u4f9b\u7cfb\u7edf\u8bbe\u8ba1\u56fe\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u4e8c\u8054\u4f9b\u7cfb\u7edf\u8bbe\u8ba1\u56fe<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-kongtiaoshejitu01.png\" alt=\"\u7a7a\u8c03\u8bbe\u8ba1\u56fe\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u7a7a\u8c03\u8bbe\u8ba1\u56fe<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-dinuanshejitu01.jpg\" alt=\"\u5730\u6696\u8bbe\u8ba1\u56fe\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u5730\u6696\u8bbe\u8ba1\u56fe<\/figcaption>\n <\/figure>\n <\/div>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-olive)\">3<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u7b2c\u4e09\u6b65\uff1a\u9690\u853d\u5de5\u7a0b\u65bd\u5de5<\/p>\n <p class=\"db-tl-d\">\n <strong>\u7a7a\u8c03\uff1a<\/strong>\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a \u2192 \u4fdd\u6e29\u68c9\u5305\u624e \u2192 \u94dc\u7ba1\u4fdd\u538b\u6d4b\u8bd5\uff0830\u5206\u949f\u22653MPa\uff09\u2192 \u51b7\u51dd\u6c34\u7ba1\u901a\u6c34\u6d4b\u8bd5 \u2192 \u5206\u533a\u56de\u8def\u7f16\u53f7\u6807\u8bc6<br>\n <strong>\u5730\u6696\uff1a<\/strong>\u94fa\u8bbePE-RT\u7ba1 \u2192 \u5206\u96c6\u6c34\u5668\u5b89\u88c5 \u2192 \u4fdd\u538b\u6d4b\u8bd5\uff080.6MPa\uff0c24\u5c0f\u65f6\uff09\u2192 \u7ae3\u5de5\u524d\u9010\u56de\u8def\u8bb0\u5f55\n <\/p>\n <div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:8px;margin-top:10px\">\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-fucaijinchangyanshou01.jpg\" alt=\"\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e00\uff09\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e00\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-fucaijinchangyanshou02.jpg\" alt=\"\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e8c\uff09\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e8c\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-fucaijinchangyanshou03.jpg\" alt=\"\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e09\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e09\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-fucaijinchangyanshou04.jpg\" alt=\"\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u56db\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u56db\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-guanluanzhuang01.jpg\" alt=\"\u7ba1\u8def\u5b89\u88c5\uff08\u4e00\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u7ba1\u8def\u5b89\u88c5\uff08\u4e00\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-guanluanzhuang02.jpg\" alt=\"\u7ba1\u8def\u5b89\u88c5\uff08\u4e8c\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u7ba1\u8def\u5b89\u88c5\uff08\u4e8c\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-guanluanzhuang03.jpg\" alt=\"\u7ba1\u8def\u5b89\u88c5\uff08\u4e09\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u7ba1\u8def\u5b89\u88c5\uff08\u4e09\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-sanguanzhineijianzhuang01.jpg\" alt=\"\u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\uff08\u4e00\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\uff08\u4e00\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-sanguanzhineijianzhuang02.jpg\" alt=\"\u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\uff08\u4e8c\uff09\" style=\"width:75%;margin:0 12.5%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd);transform:rotate(-90deg)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\uff08\u4e8c\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-danqibaohuhanjie01.jpg\" alt=\"\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff08\u4e00\uff09\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff08\u4e00\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-danqibaohuhanjie02.jpg\" alt=\"\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff08\u4e8c\uff09\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff08\u4e8c\uff09<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-qwi-xxp-quanxiao200waijianzhuang01.jpg\" alt=\"\u5168\u6548200\u5916\u673a\u5b89\u88c5\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u5168\u6548200\u5916\u673a\u5b89\u88c5<\/figcaption>\n <\/figure>\n <\/div>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-amber)\">4<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u7b2c\u56db\u6b65\uff1a\u76d1\u7406\u5230\u4f4d<\/p>\n <p class=\"db-tl-d\">\u76d1\u7406\u5de1\u68c0\u9690\u853d\u5de5\u7a0b\u5173\u952e\u8282\u70b9\uff1a\u94dc\u7ba1\u710a\u63a5\u8d28\u91cf\u3001\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\u3001\u4fdd\u538b\u6d4b\u8bd5\u8bb0\u5f55\u3001\u9632\u62a4\u63aa\u65bd\u3002\u53d1\u73b0\u95ee\u9898\u5f53\u573a\u5904\u7406\uff0c\u62cd\u7167\u7559\u6863<\/p>\n <div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:8px;margin-top:10px\">\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gw-qwi-xxp-neijijianzhendianyanshou.jpg\" alt=\"\u5185\u673a\u51cf\u9707\u57ab\u9a8c\u6536\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u5185\u673a\u51cf\u9707\u57ab\u9a8c\u6536<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gw-qwi-xxp-neijijiekoubaowenyanshou.jpg\" alt=\"\u5185\u673a\u63a5\u53e3\u4fdd\u6e29\u9a8c\u6536\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u5185\u673a\u63a5\u53e3\u4fdd\u6e29\u9a8c\u6536<\/figcaption>\n <\/figure>\n <figure style=\"margin:0\">\n <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gw-qwi-xxp-lengningshuipaiqiguanyanshou.jpg\" alt=\"\u51b7\u51dd\u6c34\u6392\u6c14\u7ba1\u9a8c\u6536\" style=\"width:100%;border-radius:var(--db-rad-sm);border:0.5px solid var(--db-bd)\" loading=\"lazy\">\n <figcaption style=\"font-size:11px;color:var(--db-txt2);text-align:center;margin-top:4px\">\u51b7\u51dd\u6c34\u6392\u6c14\u7ba1\u9a8c\u6536<\/figcaption>\n <\/figure>\n <\/div>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-purple)\">5<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/p>\n <p class=\"db-tl-d\">\u5355\u673a\u8c03\u8bd5\uff08\u51fa\u98ce\u6e29\u5ea6\u53ef\u8c03\uff09\u2192 \u7cfb\u7edf\u8054\u8c03\uff08\u7a7a\u8c03+\u5730\u6696\u8054\u52a8\uff09\u2192 \u5ba2\u6237\u57f9\u8badAPP\u64cd\u4f5c<\/p>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-red)\">6<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536<\/p>\n <p class=\"db-tl-d\">\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c \/ \u7a7a\u8c03\u9001\u98ce\u53e3\u5b9e\u6d4b \/ \u5730\u6696\u5404\u533a\u51fa\u6c34\u6e29\u5ea6\u786e\u8ba4 \/ APP\u8fdc\u7a0b\u63a7\u5236\u6f14\u793a \/ \u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\uff0c\u9a8c\u6536\u7167\u7247\u5b58\u6863\uff0c\u6863\u6848\u5efa\u7acb<\/p>\n <\/div>\n <\/div>\n<\/div>\n<div class=\"db-info\" style=\"background:var(--db-olive-bg)\">\n <span style=\"font-weight:500;color:var(--db-olive)\">\ud83d\udcce \u65bd\u5de5\u6807\u51c6\uff1a<\/span>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6\uff0c\u81ea\u6709\u5de5\u4eba\u975e\u5916\u5305\uff0c\u9690\u853d\u5de5\u7a0b\u5168\u7a0b\u62cd\u7167\u7559\u6863\uff0c\u4e00\u6237\u4e00\u6863\u53ef\u8ffd\u6eaf\u3002\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u65bd\u5de5\u5468\u671f\u53c2\u8003<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u7a7a\u8c03 3-4\u5929<\/span><span class=\"db-tag db-tag-green\">\u5730\u6696 2-3\u5929<\/span><span class=\"db-tag db-tag-purple\">\u4ea4\u53c9\u65bd\u5de5\u7edf\u4e00\u534f\u8c03<\/span><\/div>'},\n\n {num:4,title:'\u4ea4\u4ed8\u4f7f\u7528',desc:'\u4ea4\u94a5\u5319\u4ea4\u4ed8\u4f53\u7cfb',color:'#BA7517',bg:'rgba(186,117,23,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-amber-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-amber)\">\u4ea4\u4ed8\u7406\u5ff5\uff1a<\/span>\u4ea4\u4ed8\u4e0d\u662f\"\u88c5\u5b8c\u4e86\"\uff0c\u800c\u662f\"\u6559\u4f1a\u60a8\u7528\"\u3002\u4ea4\u94a5\u5319\u5f53\u65e5\uff0c\u7531\u65b9\u6848\u987e\u95ee\u5e26\u961f\u5b8c\u6210\u5168\u5957\u4ea4\u4ed8\u6d41\u7a0b\u3002\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u4ea4\u4ed8\u524d \u00b7 \u68c0\u67e5\u6e05\u5355<\/h4>\n<table style=\"margin-bottom:12px\">\n <thead><tr><th>\u68c0\u67e5\u9879<\/th><th>\u6807\u51c6<\/th><th>\u786e\u8ba4<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u7a7a\u8c03\u5f00\u5173\u673a<\/td><td>\u5404\u5185\u673a\u72ec\u7acb\u5f00\u5173\u3001\u6a21\u5f0f\u5207\u6362\u6b63\u5e38<\/td><td>\u5f85\u7b7e\u5b57<\/td><\/tr>\n <tr><td>\u5730\u6696\u542f\u505c<\/td><td>\u5404\u56de\u8def\u901a\u65ad\u6b63\u5e38\uff0c\u5206\u96c6\u6c34\u5668\u9600\u95e8\u7075\u6d3b<\/td><td>\u5f85\u7b7e\u5b57<\/td><\/tr>\n <tr><td>\u9001\u56de\u98ce\u53e3<\/td><td>\u65e0\u906e\u6321\uff0c\u767e\u53f6\u65b9\u5411\u53ef\u8c03\uff0c\u98ce\u901f\u6b63\u5e38<\/td><td>\u5f85\u7b7e\u5b57<\/td><\/tr>\n <tr><td>\u7ebf\u63a7\u5668\/APP<\/td><td>\u5404\u623f\u95f4\u72ec\u7acb\u63a7\u5236\u6b63\u5e38\uff0c\u8fdc\u7a0b\u5f00\u5173\u6b63\u5e38<\/td><td>\u5f85\u7b7e\u5b57<\/td><\/tr>\n <tr><td>\u6392\u6c34\u6d4b\u8bd5<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u6392\u6c34\u901a\u7545\uff0c\u65e0\u5012\u704c<\/td><td>\u5f85\u7b7e\u5b57<\/td><\/tr>\n <tr><td>\u5916\u89c2\u68c0\u67e5<\/td><td>\u9762\u677f\u65e0\u5212\u75d5\uff0c\u98ce\u53e3\u989c\u8272\u7edf\u4e00<\/td><td>\u5f85\u7b7e\u5b57<\/td><\/tr>\n <\/tbody>\n<\/table>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px\">\u4ea4\u4ed8\u5f53\u65e5 \u00b7 \u56db\u6b65\u4ea4\u94a5\u5319\u6d41\u7a0b<\/h4>\n<div class=\"db-timeline\">\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-blue)\">1<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u73b0\u573a\u64cd\u4f5c\u57f9\u8bad<\/p>\n <p class=\"db-tl-d\">\u7ebf\u63a7\u5668\u57fa\u7840\u64cd\u4f5c\uff08\u5f00\u5173\/\u6a21\u5f0f\/\u6e29\u5ea6\/\u98ce\u901f\/\u5b9a\u65f6\uff09\u2192 APP\u8fdc\u7a0b\u63a7\u5236\u6f14\u793a \u2192 \u9664\u6e7f\u6a21\u5f0f\u4e13\u9879\u8bf4\u660e\uff08\u4e09\u7ba1\u5236\u5185\u673a\uff09\u2192 \u81ea\u6e05\u6d01\u64cd\u4f5c<\/p>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-green)\">2<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u5168\u7cfb\u7edf\u8054\u52a8\u6f14\u793a<\/p>\n <p class=\"db-tl-d\">\u7a7a\u8c03+\u5730\u6696\u540c\u65f6\u8fd0\u884c\u9a8c\u8bc1 \u2192 \u5404\u623f\u95f4\u9010\u4e00\u70b9\u68c0 \u2192 \u6548\u679c\u5ba2\u6237\u4eb2\u773c\u786e\u8ba4\uff08\u4f53\u611f+\u4eea\u8868\u6570\u636e\u53cc\u9a8c\u8bc1\uff09<\/p>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-amber)\">3<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u8d44\u6599\u79fb\u4ea4<\/p>\n <p class=\"db-tl-d\">\u8bbe\u5907\u8bf4\u660e\u4e66 \u2192 \u7ebf\u63a7\u5668\u7b80\u660e\u624b\u518c \u2192 \u6ee4\u7f51\u6e05\u6d17\u56fe\u89e3 \u2192 \u6863\u6848\u4e66\u7535\u5b50\u7248 \u2192 \u552e\u540e\u8054\u7cfb\u5361<\/p>\n <\/div>\n <\/div>\n <div class=\"db-tl-item\">\n <div class=\"db-tl-dot\" style=\"background:var(--db-red)\">4<\/div>\n <div class=\"db-tl-body\">\n <p class=\"db-tl-h\">\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4<\/p>\n <p class=\"db-tl-d\">\u4ea4\u4ed8\u9a8c\u6536\u5355\u7b7e\u5b57 \u2192 \u6863\u6848\u5efa\u7acb \u2192 \u4f1a\u5458\u5f00\u901a\uff08\u5982\u5df2\u52a0\u5165\uff09\u2192 \u9996\u5e74\u7ef4\u4fdd\u8ba1\u5212\u544a\u77e5<\/p>\n <\/div>\n <\/div>\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px;margin-top:10px\">\u4ea4\u4ed8\u540e \u00b7 \u9996\u6708\u8ddf\u8e2a<\/h4>\n<table>\n <tr><th>\u65f6\u95f4\u8282\u70b9<\/th><th>\u8ddf\u8fdb\u884c\u52a8<\/th><\/tr>\n <tr><td>\u4ea4\u4ed8\u540e\u7b2c3\u5929<\/td><td>\u7535\u8bdd\u56de\u8bbf\uff1a\u64cd\u4f5c\u662f\u5426\u987a\u624b\uff0c\u6709\u65e0\u7591\u95ee<\/td><\/tr>\n <tr><td>\u4ea4\u4ed8\u540e\u7b2c7\u5929<\/td><td>\u5fae\u4fe1\u56de\u8bbf\uff1a\u5236\u51b7\/\u5236\u70ed\u6548\u679c\u662f\u5426\u6ee1\u610f<\/td><\/tr>\n <tr><td>\u4ea4\u4ed8\u540e\u7b2c30\u5929<\/td><td>\u4e0a\u95e8\u590d\u68c0\uff1a\u6ee4\u7f51\u72b6\u6001\u3001\u6392\u6c34\u901a\u7545\u3001\u5730\u6696\u7ba1\u8def<\/td><\/tr>\n<\/table>`,\n rec:'<div class=\"db-recbar-title\">\u4ea4\u4ed8\u6846\u67b6<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u68c0\u67e5\u6e05\u5355<\/span><span class=\"db-tag db-tag-green\">\u73b0\u573a\u57f9\u8bad<\/span><span class=\"db-tag db-tag-amber\">\u8d44\u6599\u79fb\u4ea4<\/span><span class=\"db-tag db-tag-red\">\u7b7e\u5b57\u5efa\u6863<\/span><\/div>'},\n\n {num:5,title:'\u4ea4\u4ed8\u6559\u5b66',desc:'\u4f7f\u7528\u8981\u70b9\u901f\u67e5',color:'#534AB7',bg:'rgba(83,74,183,0.08)',\n content:`\n<table style=\"margin-bottom:12px\">\n <thead><tr><th style=\"width:140px\">\u64cd\u4f5c\u8981\u70b9<\/th><th>\u8bbe\u5b9a\/\u64cd\u4f5c\u65b9\u5f0f<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u5236\u51b7\u6a21\u5f0f<\/td><td>\u590f\u5b63\u8bbe\u5b9a\u6e29\u5ea6 <span class=\"db-hi-blue\">24-26\u2103<\/span>\uff0c\u6e7f\u5ea6 40%-60%<\/td><\/tr>\n <tr><td>\u5236\u70ed\u6a21\u5f0f<\/td><td>\u51ac\u5b63\u8bbe\u5b9a\u6e29\u5ea6 <span class=\"db-hi-amber\">18-22\u2103<\/span>\uff08\u7a7a\u8c03+\u5730\u6696\u8054\u52a8\u6700\u8212\u9002\uff09<\/td><\/tr>\n <tr><td>\u5730\u6696\u5f00\u542f<\/td><td>\u51ac\u5b63\u63d0\u524d1-2\u5c0f\u65f6\u5f00\u542f\uff0c\u5730\u6696\u70ed\u60f0\u6027\u5927\uff0c\u4e0d\u5efa\u8bae\u9891\u7e41\u5f00\u5173<\/td><\/tr>\n <tr><td>\u98ce\u901f\u5efa\u8bae<\/td><td>\u81ea\u52a8\u98ce\u901f\u4f18\u5148\uff1b\u7761\u7720\u65f6\u53ef\u624b\u52a8\u8c03\u81f3\u4f4e\u98ce\u6216\u9759\u97f3\u6863<\/td><\/tr>\n <tr><td>\u6ee4\u7f51\u6e05\u6d17<\/td><td>\u6bcf\u6708\u6e05\u6d17\u4e00\u6b21\uff08\u56de\u98ce\u53e3\u6ee4\u7f51\uff0c\u6e05\u6c34\u51b2\u6d17\u667e\u5e72\u540e\u88c5\u56de\uff09<\/td><\/tr>\n <tr><td>\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><td>\u6362\u5b63\u65f6\u8fd0\u884c\u4e00\u6b21\uff08\u7ea630\u5206\u949f\uff09\uff0c\u957f\u6309\"\u81ea\u6e05\u6d01\"\u952e\u542f\u52a8<\/td><\/tr>\n <tr><td>\u5916\u673a\u6563\u70ed<\/td><td>\u786e\u4fdd\u5916\u673a\u5468\u56f4\u65e0\u6742\u7269\u5806\u653e\uff0c\u901a\u98ce\u826f\u597d<\/td><\/tr>\n <tr><td>\u957f\u65f6\u95f4\u4e0d\u7528<\/td><td>\u65ad\u7535\uff0c\u6e05\u6d17\u6ee4\u7f51\u540e\u5173\u673a\uff1b\u5730\u6696\u9632\u51bb\u6a21\u5f0f\u4fdd\u630110\u2103\u4ee5\u4e0a<\/td><\/tr>\n <\/tbody>\n<\/table>\n<div class=\"db-info\" style=\"background:var(--db-purple-bg)\">\n <span style=\"font-weight:500;color:var(--db-purple)\">\ud83d\udca1 \u7279\u522b\u63d0\u9192\uff1a<\/span>\u5bf9\u7a7a\u6c14\u654f\u611f\u7684\u7528\u6237\uff0c\u5efa\u8bae\u6bcf\u6708\u5b9a\u671f\u6e05\u6d17\u56de\u98ce\u53e3\u6ee4\u7f51\uff0c\u6362\u5b63\u524d\u8fd0\u884c\u4e00\u6b21\u9ad8\u6e29\u9664\u83cc\uff0860\u2103\uff0c\u7ea630\u5206\u949f\uff09\u3002PE\u51c0\u5316\u6a21\u5757\uff08\u65b9\u6848A\u6807\u914d\uff09\u5efa\u8bae\u6bcf\u534a\u5e74\u68c0\u67e5\u4e00\u6b21\u5438\u9644\u677f\u72b6\u6001\u3002\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u4f7f\u7528\u63d0\u9192<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u6ee4\u7f51\u6bcf\u6708\u6e05\u6d17<\/span><span class=\"db-tag db-tag-red\">\u6362\u5b63\u9ad8\u6e29\u9664\u83cc<\/span><span class=\"db-tag db-tag-green\">\u5730\u6696\u63d0\u524d\u9884\u70ed<\/span><\/div>'},\n\n {num:6,title:'\u8d28\u4fdd\u4e0e\u552e\u540e',desc:'\u4fdd\u969c\u653f\u7b56\u8be6\u60c5',color:'#A32D2D',bg:'rgba(163,45,45,0.08)',\n content:`\n<div class=\"db-commit-grid\">\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83c\udfed \u8bbe\u5907\u8d28\u4fdd<\/p>\n <p class=\"db-ccd\">\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd\uff0c\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u542b\u88c5\u4fee\u671f6\u4e2a\u6708+\u6574\u673a\u8d28\u4fdd60\u4e2a\u6708\uff09<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udd17 \u4e09\u65b9\u8054\u4fdd<\/p>\n <p class=\"db-ccd\">\u9f99\u8109\u6696\u901a + \u65e5\u7acb\u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd\uff0c5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd\uff0c\u4e1a\u5185\u6700\u5f3a\u4fdd\u969c<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udc51 \u4f1a\u5458\u670d\u52a1<\/p>\n <p class=\"db-ccd\">199\u5143\/\u5e74\uff0c\u5e74\u5ea6\u68c0\u6d4b\/\u7ef4\u4fdd\u63d0\u9192\/\u4f18\u5148\u54cd\u5e94\/\u670d\u52a1\u6298\u6263\/\u8fdc\u7a0b\u8bca\u65ad\uff0c\u4f1a\u5458\u8d28\u4fdd\u5ef6\u81f310\u5e74<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udcde \u7d27\u6025\u62a5\u4fee<\/p>\n <p class=\"db-ccd\">24h\u54cd\u5e94\uff0c\u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8\u3002\u65e5\u7acb\u5b98\u65b9400\u7535\u8bdd + \u9f99\u8109\u6696\u901a\u552e\u540e\u4e13\u7ebf<\/p>\n <\/div>\n<\/div>\n<table>\n <thead><tr><th style=\"width:120px\">\u4fdd\u969c\u9879<\/th><th>\u975e\u4f1a\u5458<\/th><th>\u4f1a\u5458\uff08199\u5143\/\u5e74\uff09<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u6574\u673a\u8d28\u4fdd<\/td><td>5\u5e74<\/td><td class=\"db-hi-green\">10\u5e74 \u2705<\/td><\/tr>\n <tr><td>\u9690\u853d\u5de5\u7a0b\u8d28\u4fdd<\/td><td>2\u5e74<\/td><td class=\"db-hi-green\">5\u5e74 \u2705<\/td><\/tr>\n <tr><td>\u5730\u6696\u8d28\u4fdd<\/td><td>5\u5e74<\/td><td class=\"db-hi-green\">10\u5e74 \u2705<\/td><\/tr>\n <tr><td>\u5e74\u5ea6\u7ef4\u4fdd<\/td><td>\u2014<\/td><td class=\"db-hi-green\">\u2705 \u542b\u5e74\u5ea6\u68c0\u6d4b<\/td><\/tr>\n <tr><td>\u8fdc\u7a0b\u8bca\u65ad<\/td><td>\u2014<\/td><td class=\"db-hi-green\">\u2705<\/td><\/tr>\n <tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u2014<\/td><td class=\"db-hi-green\">\u2705 \u51ac\u590f\u9ad8\u5cf0\u4f18\u5148\u6d3e\u5355<\/td><\/tr>\n <tr><td>\u7cfb\u7edf\u5f02\u5e38\u4e0a\u95e8<\/td><td>\u6536\u8d39<\/td><td class=\"db-hi-green\">\u2705 \u4e0d\u9650\u6b21\u6570\u514d\u8d39<\/td><\/tr>\n <\/tbody>\n<\/table>` ,\n rec:'<div class=\"db-recbar-title\">\u8d28\u4fdd\u5bf9\u6bd4<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-green\">\u6574\u673a5\u219210\u5e74<\/span><span class=\"db-tag db-tag-blue\">\u4e09\u65b9\u8054\u4fdd<\/span><span class=\"db-tag db-tag-amber\">\u4f1a\u5458\u5e74\u5ea6\u7ef4\u4fdd<\/span><span class=\"db-tag db-tag-red\">24h\u54cd\u5e94<\/span><\/div>'}\n],\n\n\/* \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500 \u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3 \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500 *\/\n3:[\n {num:1,title:'\u516d\u7ef4\u5ea6\u8ddf\u8e2a',desc:'\u5168\u9762\u80fd\u8017\u76d1\u63a7',color:'#0F6E56',bg:'rgba(15,110,86,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-green-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-green)\">\u8ddf\u8e2a\u7406\u5ff5\uff1a<\/span>\u516d\u4e2a\u7ef4\u5ea6\uff0c\u8986\u76d6\u60a8\u771f\u6b63\u5173\u5fc3\u7684\u6bcf\u4e00\u7b14\u8d26\u3002\u6bcf\u5e74\u66f4\u65b0\uff0c\u6570\u636e\u968f\u65f6\u53ef\u67e5\u3002\n<\/div>\n<div class=\"db-commit-grid\">\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udcb0 \u8fd0\u884c\u8d39<\/p>\n <p class=\"db-ccd\">\u6bcf\u5e74\u5b9e\u9645\u7535\u8d39\u8bb0\u5f55\uff0c\u4e0e\u8bbe\u8ba1\u9884\u7b97\u5bf9\u6bd4\uff0c\u8ba1\u7b97\u8282\u7701\/\u8d85\u652f\u539f\u56e0<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udd27 \u7ef4\u62a4\u8d39<\/p>\n <p class=\"db-ccd\">\u51fa\u8fc7\u51e0\u6b21\u6545\u969c\u3001\u4fee\u4e86\u591a\u5c11\u94b1\uff0c\u6e05\u6670\u8bb0\u5f55\u6bcf\u7b14\u7ef4\u62a4\u652f\u51fa<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\u23f3 \u4f7f\u7528\u5bff\u547d<\/p>\n <p class=\"db-ccd\">\u4e3b\u673a\u3001\u63a7\u5236\u7cfb\u7edf\u3001\u5730\u6696\u7ba1\u9053\u7684\u5b9e\u9645\u4f7f\u7528\u5e74\u9650\u8ddf\u8e2a\u8bc4\u4f30<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\u2699\ufe0f \u7cfb\u7edf\u7a33\u5b9a\u6027<\/p>\n <p class=\"db-ccd\">\u6709\u6ca1\u6709\u9891\u7e41\u542f\u505c\u3001\u51b7\u70ed\u4e0d\u5747\uff0c\u5168\u90e8\u8bb0\u5f55\u5728\u6848<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83c\udf21\ufe0f \u8212\u9002\u5ea6<\/p>\n <p class=\"db-ccd\">\u51ac\u5929\u80fd\u4e0d\u80fd\u70ed\u8d77\u6765\uff08\u60a8\u6700\u5173\u5fc3\u8fd9\u4e2a\uff09\uff0c\u590f\u5929\u4f1a\u4e0d\u4f1a\u95f7\uff0c\u7a7a\u6c14\u662f\u5426\u6d01\u51c0<\/p>\n <\/div>\n <div class=\"db-commit-card\">\n <p class=\"db-cch\">\ud83d\udcb5 \u521d\u6295\u8d44\u56de\u987e<\/p>\n <p class=\"db-ccd\">\u60a8\u524d\u671f\u82b1\u4e86\u591a\u5c11\u94b1\uff0c\u4e0e\u9884\u7b97\u5bf9\u6bd4\uff0c\u4e0e\u540c\u7c7b\u65b9\u6848\u5bf9\u6bd4\uff0c\u8bc1\u660e\u9009\u62e9\u662f\u5426\u503c\u5f97<\/p>\n <\/div>\n<\/div>\n<h4 style=\"font-size:12px;font-weight:500;color:var(--db-txt2);margin-bottom:8px;margin-top:4px\">\u5e74\u5ea6\u8fd0\u884c\u8d39\u53c2\u8003\uff08\u9884\u4f30\uff09<\/h4>\n<table>\n <tr><th>\u9879\u76ee<\/th><th>\u65b9\u6848A<\/th><th>\u65b9\u6848B<\/th><\/tr>\n <tr><td>\u7a7a\u8c03\u5e74\u8fd0\u884c\u8d39\uff08\u5236\u51b7+\u5236\u70ed\uff09<\/td><td>\u7ea61,800-2,200\u5143<\/td><td>\u7ea61,800-2,200\u5143<\/td><\/tr>\n <tr><td>\u5730\u6696\u5e74\u8fd0\u884c\u8d39\uff08\u91c7\u6696\u5b63\uff09<\/td><td>\u7ea61,200-1,600\u5143<\/td><td>\u7ea61,200-1,600\u5143<\/td><\/tr>\n <tr><td><strong>\u5408\u8ba1\u4f30\u7b97<\/strong><\/td><td class=\"db-hi-blue\"><strong>\u7ea63,000-3,800\u5143\/\u5e74<\/strong><\/td><td class=\"db-hi-green\"><strong>\u7ea63,000-3,800\u5143\/\u5e74<\/strong><\/td><\/tr>\n<\/table>`,\n rec:'<div class=\"db-recbar-title\">\u516d\u7ef4\u8ddf\u8e2a<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-blue\">\u8fd0\u884c\u8d39<\/span><span class=\"db-tag db-tag-green\">\u7ef4\u62a4\u8d39<\/span><span class=\"db-tag db-tag-amber\">\u5bff\u547d<\/span><span class=\"db-tag db-tag-purple\">\u7a33\u5b9a\u6027<\/span><span class=\"db-tag db-tag-red\">\u8212\u9002\u5ea6<\/span><span class=\"db-tag db-tag-olive\">\u521d\u6295\u8d44\u56de\u987e<\/span><\/div>'},\n\n {num:2,title:'\u552e\u540e\u670d\u52a1\u8bb0\u5f55',desc:'\u6bcf\u6b21\u7ef4\u4fdd\u5b58\u6863',color:'#BA7517',bg:'rgba(186,117,23,0.08)',\n content:`\n<div class=\"db-info\" style=\"background:var(--db-amber-bg);margin-bottom:12px\">\n <span style=\"font-weight:500;color:var(--db-amber)\">\ud83d\udccb \u8bb0\u5f55\u89c4\u5219\uff1a<\/span>\u6bcf\u6b21\u7ef4\u4fdd\u3001\u68c0\u6d4b\u3001\u6e05\u6d17\u5747\u8bb0\u5f55\u5728\u6848\uff0c\u5305\u62ec\uff1a\u670d\u52a1\u65e5\u671f\u3001\u670d\u52a1\u7c7b\u578b\u3001\u670d\u52a1\u5185\u5bb9\u3001\u670d\u52a1\u4eba\u5458\u3001\u5ba2\u6237\u786e\u8ba4\u7b7e\u5b57\u3002\n<\/div>\n<table>\n <thead><tr><th>\u65e5\u671f<\/th><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u670d\u52a1\u5185\u5bb9<\/th><th>\u670d\u52a1\u4eba\u5458<\/th><th>\u5ba2\u6237\u786e\u8ba4<\/th><\/tr><\/thead>\n <tbody>\n <tr><td>\u7ae3\u5de5\u9a8c\u6536<\/td><td>\u4ea4\u4ed8\u9a8c\u6536<\/td><td>\u5168\u7cfb\u7edf\u8054\u8c03\u3001\u4f7f\u7528\u57f9\u8bad\u3001\u7b7e\u5b57\u786e\u8ba4<\/td><td>\u5f85\u586b\u5199<\/td><td>\u5f85\u586b\u5199<\/td><\/tr>\n <tr><td>\u7b2c1\u5e74\u56de\u8bbf<\/td><td>\u5e74\u5ea6\u68c0\u6d4b<\/td><td>\u6ee4\u7f51\u6e05\u6d17\u3001\u5236\u51b7\u5236\u70ed\u68c0\u6d4b\u3001\u5730\u6696\u7ba1\u8def\u68c0\u67e5\u3001\u51b7\u51dd\u6c34\u68c0\u67e5<\/td><td>\u2014<\/td><td>\u5f85\u586b\u5199<\/td><\/tr>\n <tr><td>\u7b2c3\u5e74\u68c0\u6d4b<\/td><td>\u6df1\u5ea6\u68c0\u6d4b<\/td><td>\u80fd\u6548\u6d4b\u8bd5\u3001PE\u51c0\u5316\u6a21\u5757\u68c0\u6d4b\u3001\u5730\u6696\u6c34\u8d28\u5316\u9a8c<\/td><td>\u2014<\/td><td>\u5f85\u586b\u5199<\/td><\/tr>\n <tr style=\"color:var(--db-txt3)\"><td colspan=\"5\" style=\"text-align:center;padding:20px;font-size:11px;\">\u540e\u7eed\u670d\u52a1\u8bb0\u5f55\u5c06\u9010\u6b65\u586b\u5165\u672c\u6863\u6848 \u00b7 \u6863\u6848\u7f16\u53f7\uff1alns-qwj-bb-01<\/td><\/tr>\n <\/tbody>\n<\/table>\n<div class=\"db-info\" style=\"background:var(--db-amber-bg);margin-top:10px\">\n <span style=\"font-weight:500;color:var(--db-amber)\">\ud83d\udcde \u8054\u7cfb\u65b9\u5f0f\uff1a<\/span>\u65b9\u6848\u987e\u95ee\u5f90\u65b0\u5e73 \u00b7 18227055065 \u00b7 \u9f99\u8109\u6696\u901a\u59cb\u4e8e2004 \u00b7 \u4f1a\u5458\u7eed\u8d39\u7387\u226570%\uff0c\u8f6c\u4ecb\u7ecd\u7387\u226530%\n<\/div>`,\n rec:'<div class=\"db-recbar-title\">\u6863\u6848\u72b6\u6001<\/div><div class=\"db-rectags\"><span class=\"db-tag db-tag-amber\">lns-qwj-bb-01<\/span><span class=\"db-tag db-tag-blue\">\u5df2\u7b7e\u7ea6<\/span><\/div>'}]\n};\n\n\/* \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n \u72b6\u6001\u7ba1\u7406\n \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 *\/\nvar currentPhase=1;\nvar currentStep=0;\nvar chartInstance=null;\n\nvar stepperEl=document.getElementById('db-stepper');\nvar panelEl=document.getElementById('db-panel');\nvar recbarEl=document.getElementById('db-recbar');\nvar chartAreaEl=document.getElementById('db-chart-area');\nvar chartTitleEl=document.getElementById('db-chart-title');\nvar chartEl=document.getElementById('db-chart');\n\n\/* \u9636\u6bb5\u5207\u6362 *\/\ndocument.getElementById('db-phase-bar').querySelectorAll('[data-phase]').forEach(function(btn){\n btn.addEventListener('click',function(){\n var p=parseInt(this.dataset.phase);\n currentPhase=p;\n currentStep=0;\n document.querySelectorAll('[data-phase]').forEach(function(b){\n b.classList.remove('db-phase-active');\n b.style.background='';b.style.borderColor='';b.style.color='';\n });\n this.classList.add('db-phase-active');\n var colors={1:'#D85A30',2:'#0F6E56',3:'#534AB7'};\n var c=colors[p]||'#D85A30';\n this.style.background=c;this.style.borderColor=c;this.style.color='#fff';\n render();\n });\n});\n\nfunction render(){\n var steps=phases[currentPhase];\n if(!steps)return;\n\n \/* \u6e32\u67d3 stepper *\/\n var groupLabels={1:'\u4e00\u9636\u6bb5',2:'\u4e8c\u9636\u6bb5',3:'\u4e09\u9636\u6bb5'};\n var html='<div class=\"db-step-group\">'+groupLabels[currentPhase]+'<\/div>';\n steps.forEach(function(s,i){\n var isActive=(i===currentStep);\n html+='<div class=\"db-step'+(isActive?' db-active':'')+'\" data-idx=\"'+i+'\" '\n +(isActive?'style=\"background:'+s.bg+';border-color:'+s.color+';color:'+s.color+'\"':'')+'>'\n +'<div class=\"db-step-num\" '+(isActive?'style=\"background:'+s.color+'\"':'')+'>'+s.num+'<\/div>'\n +'<div class=\"db-step-body\">'\n +'<div class=\"db-step-title\">'+s.title+'<\/div>'\n +'<div class=\"db-step-desc\">'+s.desc+'<\/div>'\n +'<\/div>'\n +'<\/div>';\n });\n stepperEl.innerHTML=html;\n stepperEl.querySelectorAll('[data-idx]').forEach(function(el){\n el.addEventListener('click',function(){\n currentStep=parseInt(this.dataset.idx);render();\n });\n });\n\n \/* \u6e32\u67d3\u9762\u677f *\/\n var s=steps[currentStep];\n panelEl.innerHTML='<div class=\"db-phead\">'\n +'<span class=\"db-phead-num\" style=\"background:'+s.color+'\">'+s.num+'<\/span>'\n +'<span class=\"db-phead-title\">'+s.title+'<\/span>'\n +'<span class=\"db-phead-sub\">'+s.desc+'<\/span>'\n +'<\/div>'+s.content;\n\n \/* \u63a8\u8350\u6807\u7b7e\u680f *\/\n var recParts=(s.rec||'').split('<div class=\"db-recbar-title\">');\n var recTitle=recParts.length>1?recParts[1].split('<\/div>')[0]:'';\n var recTagsParts=(s.rec||'').split('<div class=\"db-rectags\">');\n var recTags=recTagsParts.length>1?recTagsParts[1].split('<\/div>')[0]:'';\n recbarEl.innerHTML='<div class=\"db-recbar-title\">'+recTitle+'<\/div>'\n +'<div class=\"db-rectags\">'+recTags+'<\/div>';\n\n \/* \u56fe\u8868\u533a *\/\n if(chartInstance){chartInstance.destroy();chartInstance=null;}\n if(currentPhase===1&&currentStep===5){\n chartAreaEl.style.display='block';\n chartTitleEl.textContent='\u65b9\u6848A vs \u65b9\u6848B \u00b7 20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\uff08\u5143\uff09';\n chartInstance=new Chart(chartEl.getContext('2d'),{\n type:'bar',\n data:{\n labels:['\u521d\u6295\u8d44','\u5e74\u8fd0\u884c\u8d39(\u00d720)','20\u5e74\u603b\u6295\u5165'],\n datasets:[\n {label:'\u65b9\u6848A \u5c0a\u777f\u5168\u6548',data:[89804,72000,161804],backgroundColor:'rgba(29,107,168,0.7)',borderColor:'#1D6BA8',borderWidth:2},\n {label:'\u65b9\u6848B \u6c34\u5885\u9002',data:[93849,72000,165849],backgroundColor:'rgba(15,110,86,0.7)',borderColor:'#0F6E56',borderWidth:2}\n ]\n },\n options:{\n responsive:true,maintainAspectRatio:false,\n plugins:{legend:{display:true,position:'bottom',labels:{font:{size:11},boxWidth:12}}},\n scales:{\n x:{grid:{display:false},ticks:{font:{size:10}}},\n y:{grid:{color:'rgba(0,0,0,0.06)'},ticks:{font:{size:11},callback:function(v){return v>=10000?(v\/10000).toFixed(0)+'\u4e07':v+''}}}\n }\n }\n });\n } else {\n chartAreaEl.style.display='none';\n }\n}\n\nrender();\n})();\n<\/script>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u5218 \u5218\u5973\u58eb \u00b7 \u5168\u5c4b\u8212\u9002\u7cfb\u7edf \u00b7 150 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":1976,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4846","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5218 \u5218\u5973\u58eb \u00b7 \u5168\u5c4b\u8212\u9002\u7cfb\u7edf \u00b7 150 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=4846\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-11T14:11:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846\",\"name\":\"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/qwj-lns-sbqd-01.jpg\",\"datePublished\":\"2026-06-28T03:14:24+00:00\",\"dateModified\":\"2026-11-11T14:11:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/qwj-lns-sbqd-01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/qwj-lns-sbqd-01.jpg\",\"width\":800,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=4846#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u5730\u6696\u600e\u4e48\u88c5\u624d\u7b97\u88c5\u5bf9\uff5c\u9009\u578b\u3001\u65bd\u5de5\u4e0e\u9a8c\u6536\u5168\u89e3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1976\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"zh_CN","og_type":"article","og_title":"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5218 \u5218\u5973\u58eb \u00b7 \u5168\u5c4b\u8212\u9002\u7cfb\u7edf \u00b7 150 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=4846","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-11T14:11:44+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=4846","url":"https:\/\/longmai-nt.com\/?page_id=4846","name":"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=4846#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=4846#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-01.jpg","datePublished":"2026-06-28T03:14:24+00:00","dateModified":"2026-11-11T14:11:44+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=4846#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=4846"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=4846#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/qwj-lns-sbqd-01.jpg","width":800,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=4846#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u5730\u6696\u600e\u4e48\u88c5\u624d\u7b97\u88c5\u5bf9\uff5c\u9009\u578b\u3001\u65bd\u5de5\u4e0e\u9a8c\u6536\u5168\u89e3","item":"https:\/\/longmai-nt.com\/?page_id=1976"},{"@type":"ListItem","position":3,"name":"\u8537\u8587\u90e1-L\u5973\u58eb\u5168\u6548\u4e8c\u8054\u4f9b\u6863\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4846"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4846\/revisions"}],"predecessor-version":[{"id":18341,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/4846\/revisions\/18341"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1976"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}