{"id":5042,"date":"2026-07-01T22:33:24","date_gmt":"2026-07-01T14:33:24","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=5042"},"modified":"2026-10-22T12:19:28","modified_gmt":"2026-10-22T04:19:28","slug":"%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e7%b3%bb%e5%88%97-%c2%b7-%e4%b8%89%e7%b3%bb%e7%bb%9f%e9%9b%86%e6%88%90%e6%96%b9%e6%a1%88%e6%8a%a5%e4%bb%b7%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=5042","title":{"rendered":"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66"},"content":{"rendered":"\n\n<style>\n  :root {\n    --primary: #1a3c6e;\n    --accent: #c41e2a;\n    --gold: #b8860b;\n    --bg-light: #f8f9fa;\n    --bg-white: #ffffff;\n    --text: #2d3436;\n    --text-light: #636e72;\n    --border: #e0e0e0;\n    --shadow: 0 2px 12px rgba(0,0,0,0.08);\n  }\n  * { margin:0; padding:0; box-sizing:border-box; }\n  body { \n    font-family: \"Microsoft YaHei\",\"PingFang SC\",\"Helvetica Neue\",sans-serif;\n    color: var(--text); line-height:1.8; background: var(--bg-light);\n  }\n\n  \/* Cover *\/\n  .cover {\n    background: linear-gradient(135deg, #0d1b3e 0%, #1a3c6e 50%, #0d2850 100%);\n    color:#fff; text-align:center; padding:80px 40px 60px; position:relative; overflow:hidden;\n  }\n  .cover::before {\n    content:''; position:absolute; top:-50%; right:-20%; width:600px; height:600px;\n    background: radial-gradient(circle, rgba(196,30,42,0.15) 0%, transparent 70%);\n  }\n  .cover-content { position:relative; z-index:1; }\n  .cover .brand { font-size:14px; letter-spacing:4px; color:rgba(255,255,255,0.6); margin-bottom:16px; }\n  .cover h1 { font-size:36px; font-weight:700; margin-bottom:12px; letter-spacing:2px; }\n  .cover .subtitle { font-size:18px; color:rgba(255,255,255,0.8); margin-bottom:30px; }\n  .cover .meta { display:flex; justify-content:center; gap:40px; flex-wrap:wrap; }\n  .cover .meta-item { text-align:center; }\n  .cover .meta-item .label { font-size:12px; color:rgba(255,255,255,0.5); text-transform:uppercase; letter-spacing:2px; }\n  .cover .meta-item .value { font-size:16px; color:#fff; margin-top:4px; }\n  .cover .divider { width:60px; height:1px; background:var(--accent); margin:30px auto; }\n\n  \/* Navigation *\/\n  .nav-fixed {\n    position:sticky; top:0; z-index:100; background:var(--primary); \n    display:flex; justify-content:center; flex-wrap:wrap; gap:4px; \n    padding:10px 20px; box-shadow:0 2px 8px rgba(0,0,0,0.3);\n  }\n  .nav-fixed a { color:rgba(255,255,255,0.85); text-decoration:none; font-size:13px; padding:6px 14px; border-radius:4px; transition:all 0.2s; white-space:nowrap; }\n  .nav-fixed a:hover { background:rgba(255,255,255,0.15); color:#fff; }\n\n  \/* Section *\/\n  .section { max-width:960px; margin:0 auto; padding:60px 30px; }\n  .section-title { \n    font-size:28px; font-weight:700; color:var(--primary); margin-bottom:8px;\n    padding-bottom:16px; border-bottom:3px solid var(--accent); position:relative;\n  }\n  .section-title .num { \n    display:inline-block; background:var(--accent); color:#fff; width:36px; height:36px; \n    border-radius:50%; text-align:center; line-height:36px; font-size:16px; margin-right:12px; \n  }\n\n  \/* Card *\/\n  .card {\n    background:var(--bg-white); border-radius:10px; padding:30px; margin:20px 0;\n    box-shadow:var(--shadow); border-left:4px solid var(--primary);\n  }\n  .card.accent-left { border-left-color:var(--accent); }\n  .card.gold-left { border-left-color:var(--gold); }\n\n  \/* Table *\/\n  .table-wrap { overflow-x:auto; margin:20px 0; }\n  table { width:100%; border-collapse:collapse; font-size:14px; }\n  th { background:var(--primary); color:#fff; padding:12px 14px; text-align:center; font-weight:600; white-space:nowrap; }\n  td { padding:10px 14px; border-bottom:1px solid var(--border); text-align:center; }\n  tr:nth-child(even) td { background:var(--bg-light); }\n  tr:hover td { background:#e8edf5; }\n  .text-left { text-align:left; }\n  .text-right { text-align:right; }\n  .highlight { font-weight:700; color:var(--accent); }\n\n  \/* Price highlight *\/\n  .total-box {\n    background:linear-gradient(135deg, #fef5f5, #fff8f0); \n    border:2px solid var(--accent); border-radius:12px; padding:30px; \n    text-align:center; margin:30px 0;\n  }\n  .total-box .total-label { font-size:16px; color:var(--text-light); margin-bottom:8px; }\n  .total-box .total-amount { font-size:42px; font-weight:800; color:var(--accent); letter-spacing:1px; }\n  .total-box .total-note { font-size:13px; color:var(--text-light); margin-top:8px; }\n\n  \/* System cards grid *\/\n  .system-grid { display:grid; grid-template-columns:repeat(auto-fit,minmax(280px,1fr)); gap:20px; margin:20px 0; }\n  .system-card { \n    background:var(--bg-white); border-radius:10px; padding:24px; box-shadow:var(--shadow);\n    border-top:3px solid var(--primary); text-align:center;\n  }\n  .system-card .icon { font-size:40px; margin-bottom:12px; }\n  .system-card h3 { font-size:18px; color:var(--primary); margin-bottom:8px; }\n  .system-card p { font-size:14px; color:var(--text-light); line-height:1.6; }\n\n  \/* Warning box *\/\n  .warn-box {\n    background:#fff8e1; border-left:4px solid #f59e0b; padding:16px 20px; \n    border-radius:6px; margin:16px 0; font-size:14px; color:#92400e;\n  }\n  .warn-box strong { color:#d97706; }\n\n  \/* Info box *\/\n  .info-box {\n    background:#e8f4fd; border-left:4px solid #3b82f6; padding:16px 20px; \n    border-radius:6px; margin:16px 0; font-size:14px; color:#1e40af;\n  }\n\n  \/* Check list *\/\n  .check-list { list-style:none; padding:0; }\n  .check-list li { padding:8px 0 8px 28px; position:relative; font-size:14px; }\n  .check-list li::before { content:'\u2713'; position:absolute; left:0; color:#10b981; font-weight:700; }\n\n  \/* Star list *\/\n  .star-list { list-style:none; padding:0; }\n  .star-list li { padding:8px 0 8px 24px; position:relative; font-size:14px; }\n  .star-list li::before { content:'\u2605'; position:absolute; left:0; color:var(--gold); }\n\n  \/* Room grid *\/\n  .room-grid { display:grid; grid-template-columns:repeat(auto-fit,minmax(260px,1fr)); gap:16px; margin:20px 0; }\n  .room-card {\n    background:var(--bg-white); border-radius:8px; padding:18px; box-shadow:var(--shadow);\n    border-top:3px solid #3b82f6;\n  }\n  .room-card h4 { font-size:15px; color:var(--primary); margin-bottom:8px; }\n  .room-card .detail { font-size:13px; color:var(--text-light); line-height:1.7; }\n\n  \/* Footer *\/\n  .footer {\n    background:var(--primary); color:rgba(255,255,255,0.8); text-align:center;\n    padding:40px 20px; font-size:13px; line-height:2;\n  }\n  .footer strong { color:#fff; }\n  .footer a { color:rgba(255,255,255,0.9); }\n\n  \/* Step flow *\/\n  .step-flow { display:flex; flex-wrap:wrap; justify-content:center; gap:12px; margin:24px 0; }\n  .step-item {\n    background:var(--bg-white); border-radius:8px; padding:16px 20px; text-align:center;\n    box-shadow:var(--shadow); min-width:120px; border-top:3px solid var(--accent);\n  }\n  .step-item .step-num { font-size:24px; font-weight:800; color:var(--accent); }\n  .step-item .step-label { font-size:12px; color:var(--text-light); margin-top:4px; }\n\n  \/* Tag *\/\n  .tag { display:inline-block; background:var(--bg-light); padding:2px 10px; border-radius:12px; font-size:12px; color:var(--text-light); font-weight:500; }\n  .tag.red { background:#fef2f2; color:#dc2626; }\n  .tag.green { background:#f0fdf4; color:#16a34a; }\n  .tag.blue { background:#eff6ff; color:#2563eb; }\n\n  \/* Print *\/\n  @media print {\n    .nav-fixed { position:relative; }\n    .section { break-inside:avoid; padding:30px 20px; }\n    body { background:#fff; }\n  }\n\n  @media (max-width:768px) {\n    .cover h1 { font-size:24px; }\n    .section { padding:40px 16px; }\n    .system-grid, .room-grid { grid-template-columns:1fr; }\n  }\n<\/style>\n\n<div class=\"cover\">\n  <div class=\"cover-content\">\n    <div class=\"brand\">HITACHI \u00b7 \u9f99\u8109\u6696\u901a \u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546<\/div>\n    <h2>\u4e2d\u592e\u7a7a\u8c03\u00b7\u65b0\u98ce\u00b7\u5730\u6696<\/h2>\n    <div class=\"subtitle\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66<\/div>\n    <div class=\"divider\"><\/div>\n    <div class=\"meta\">\n      <div class=\"meta-item\"><div class=\"label\">\u5ba2\u6237<\/div><div class=\"value\">\u65b0\u7586\u5ba2\u6237<\/div><\/div>\n      <div class=\"meta-item\"><div class=\"label\">\u91c7\u6696\u9762\u79ef<\/div><div class=\"value\">121 \u33a1<\/div><\/div>\n      <div class=\"meta-item\"><div class=\"label\">\u697c\u5c42<\/div><div class=\"value\">\u4e24\u5c42\uff08\u4e00\u697c+\u4e8c\u697c\uff09<\/div><\/div>\n      <div class=\"meta-item\"><div class=\"label\">\u7cfb\u7edf\u7c7b\u578b<\/div><div class=\"value\">\u7a7a\u8c03\u4e00\u62d6\u4e94 + \u65b0\u98ce + \u9505\u7089\u5730\u6696<\/div><\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<nav class=\"nav-fixed\">\n  <a href=\"#s1\">\ud83d\udccb \u9879\u76ee\u6982\u51b5<\/a>\n  <a href=\"#s2\">\ud83d\udcd0 \u8bbe\u8ba1\u4f9d\u636e<\/a>\n  <a href=\"#s3\">\ud83d\udd27 \u7cfb\u7edf\u65b9\u6848<\/a>\n  <a href=\"#s4\">\ud83d\udcca \u8bbe\u5907\u6e05\u5355<\/a>\n  <a href=\"#s5\">\ud83e\uddf0 \u8f85\u6750\u6e05\u5355<\/a>\n  <a href=\"#s6\">\ud83d\udcb0 \u62a5\u4ef7\u660e\u7ec6<\/a>\n  <a href=\"#s7\">\ud83c\udfd7 \u65bd\u5de5\u670d\u52a1<\/a>\n  <a href=\"#s8\">\ud83d\udee1 \u552e\u540e\u4fdd\u969c<\/a>\n  <a href=\"#s9\">\u26a1 10\u5e74\u80fd\u6e90\u4fdd\u969c<\/a>\n  <a href=\"#s10\">\ud83d\udcde \u8054\u7cfb\u6211\u4eec<\/a>\n<\/nav>\n\n<div class=\"section\" id=\"s1\">\n  <h2 class=\"section-title\"><span class=\"num\">1<\/span> \u9879\u76ee\u6982\u51b5<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:16px;\">\u5ba2\u6237\u9700\u6c42\u753b\u50cf<\/h3>\n    <table>\n      <tbody><tr><td style=\"width:120px;font-weight:600;background:var(--bg-light);\">\u6838\u5fc3\u9700\u6c42<\/td><td>\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u96c6\u6210\uff0c\u6027\u4ef7\u6bd4\u9ad8\uff0c\u7cfb\u7edf\u7a33\u5b9a\uff0c\u5236\u51b7\u5236\u70ed\u6548\u679c\u597d<\/td><\/tr>\n      <tr><td style=\"font-weight:600;background:var(--bg-light);\">\u5ba2\u6237\u6765\u6e90<\/td><td>\u65b0\u7586\u7c4d \u00b7 \u623f\u5c4b\u4f4d\u4e8e\u6210\u90fd\u5730\u533a<\/td><\/tr>\n      <tr><td style=\"font-weight:600;background:var(--bg-light);\">\u91c7\u6696\u9762\u79ef<\/td><td class=\"highlight\">121 \u33a1<\/td><\/tr>\n      <tr><td style=\"font-weight:600;background:var(--bg-light);\">\u697c\u5c42\u5206\u5e03<\/td><td>\u4e00\u697c\uff1a\u5ba2\u9910\u5385 + \u6b21\u5367\uff1b\u4e8c\u697c\uff1a\u4e3b\u5367 + \u6b21\u5367 + \u4e66\u623f + \u8fc7\u9053<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:16px;\">\ud83c\udfe0 \u9010\u623f\u95f4\u9762\u79ef\u4e0e\u7528\u9014<\/h3>\n    <div class=\"room-grid\">\n      <div class=\"room-card\">\n        <h4>\ud83d\udecb \u4e00\u697c \u00b7 \u5ba2\u5385\u9910\u5385<\/h4>\n        <div class=\"detail\">\n          \u9762\u79ef\uff1a<strong>56.36 \u33a1<\/strong><br>\n          \u7528\u9014\uff1a\u5bb6\u5ead\u6d3b\u52a8\u4e2d\u5fc3\u3001\u65e5\u5e38\u8d77\u5c45\u3001\u4f1a\u5ba2<br>\n          \u7a7a\u8c03\u914d\u7f6e\uff1a71\u5185\u673a\uff087.1kW\uff09<br>\n          \u65b0\u98ce\u8986\u76d6\uff1a\u2714 \u4e00\u697c\u5171\u7528\n        <\/div>\n      <\/div>\n      <div class=\"room-card\">\n        <h4>\ud83d\udecf \u4e00\u697c \u00b7 \u6b21\u5367<\/h4>\n        <div class=\"detail\">\n          \u9762\u79ef\uff1a<strong>9.92 \u33a1<\/strong><br>\n          \u7528\u9014\uff1a\u5ba2\u623f\/\u8001\u4eba\u623f<br>\n          \u7a7a\u8c03\u914d\u7f6e\uff1a22\u5185\u673a\uff082.2kW\uff09<br>\n          \u65b0\u98ce\u8986\u76d6\uff1a\u2714\n        <\/div>\n      <\/div>\n      <div class=\"room-card\">\n        <h4>\ud83d\udecf \u4e8c\u697c \u00b7 \u4e3b\u5367<\/h4>\n        <div class=\"detail\">\n          \u9762\u79ef\uff1a<strong>22 \u33a1<\/strong><br>\n          \u7528\u9014\uff1a\u4e3b\u4eba\u5367\u5ba4<br>\n          \u7a7a\u8c03\u914d\u7f6e\uff1a36\u5185\u673a\uff083.6kW\uff09<br>\n          \u65b0\u98ce\u8986\u76d6\uff1a\u2714 \u8de8\u5c42\u5b89\u88c5\n        <\/div>\n      <\/div>\n      <div class=\"room-card\">\n        <h4>\ud83d\udecf \u4e8c\u697c \u00b7 \u6b21\u5367<\/h4>\n        <div class=\"detail\">\n          \u9762\u79ef\uff1a<strong>18.2 \u33a1<\/strong><br>\n          \u7528\u9014\uff1a\u5b50\u5973\u623f\/\u5ba2\u623f<br>\n          \u7a7a\u8c03\u914d\u7f6e\uff1a32\u5185\u673a\uff083.2kW\uff09<br>\n          \u65b0\u98ce\u8986\u76d6\uff1a\u2714\n        <\/div>\n      <\/div>\n      <div class=\"room-card\">\n        <h4>\ud83d\udeb6 \u4e8c\u697c \u00b7 \u8fc7\u9053<\/h4>\n        <div class=\"detail\">\n          \u9762\u79ef\uff1a<strong>6.76 \u33a1<\/strong><br>\n          \u7528\u9014\uff1a\u4ea4\u901a\u7a7a\u95f4<br>\n          \u7a7a\u8c03\u914d\u7f6e\uff1a\u4e0d\u72ec\u7acb\u8bbe\u7f6e\uff08\u8fc7\u6e21\u533a\u57df\uff09<br>\n          \u5730\u6696\u8986\u76d6\uff1a\u2714\n        <\/div>\n      <\/div>\n    <\/div>\n    <div class=\"info-box\" style=\"margin-top:16px;\">\n      <strong>\ud83d\udca1 \u8bbe\u8ba1\u8bf4\u660e\uff1a<\/strong>\u4e8c\u697c\u8fc7\u9053\u4e3a\u8fc7\u6e21\u7a7a\u95f4\uff0c\u4e0d\u5355\u72ec\u8bbe\u7f6e\u7a7a\u8c03\u672b\u7aef\uff0c\u5176\u51b7\u70ed\u91cf\u901a\u8fc7\u76f8\u90bb\u623f\u95f4\u81ea\u7136\u6e17\u900f\u6ee1\u8db3\u3002\u65b0\u98ce\u7cfb\u7edf\u91c7\u7528\u8de8\u5c42\u5b89\u88c5\u65b9\u6848\uff0c\u8986\u76d6\u4e00\u697c\u5ba2\u9910\u5385+\u6b21\u5367\uff0c\u4ee5\u53ca\u4e8c\u697c\u4e3b\u5367+\u6b21\u5367+\u4e66\u623f\u5171\u4e94\u4e2a\u623f\u95f4\uff08\u7ea6116\u33a1\uff09\uff0c350\u98ce\u91cf\u5b9e\u73b0\u5168\u5c4b\u7ea61\u6b21\/\u5c0f\u65f6\u7684\u6362\u6c14\u7387\u3002\u8de8\u5c42\u65bd\u5de5\u9700\u589e\u52a0\u7acb\u7ba1\u7a7f\u697c\u677f\u7684\u5bc6\u5c01\u9632\u6c34\u5904\u7406\u53ca\u989d\u5916\u7ba1\u8def\u6750\u6599\u3002\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s2\">\n  <h2 class=\"section-title\"><span class=\"num\">2<\/span> \u8bbe\u8ba1\u4f9d\u636e<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:16px;\">\ud83d\udcdc \u8bbe\u8ba1\u6807\u51c6\u4e0e\u89c4\u8303<\/h3>\n    <table>\n      <tbody><tr><th style=\"width:40%;\">\u6807\u51c6\/\u89c4\u8303<\/th><th>\u9002\u7528\u8303\u56f4<\/th><\/tr>\n      <tr><td class=\"text-left\">GB50736-2012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td><td>\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97\u57fa\u7840\u6807\u51c6<\/td><\/tr>\n      <tr><td class=\"text-left\">GB\/T 18837-2015\u300a\u591a\u8054\u5f0f\u7a7a\u8c03\uff08\u70ed\u6cf5\uff09\u673a\u7ec4\u300b<\/td><td>\u4e2d\u592e\u7a7a\u8c03\u4e3b\u673a\u6027\u80fd\u6807\u51c6<\/td><\/tr>\n      <tr><td class=\"text-left\">GB50242-2002\u300a\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303\u300b<\/td><td>\u5730\u6696\u7cfb\u7edf\u65bd\u5de5\u9a8c\u6536\u6807\u51c6<\/td><\/tr>\n      <tr><td class=\"text-left\">GB\/T 34010-2017\u300a\u5efa\u7b51\u901a\u98ce\u6548\u679c\u6d4b\u8bd5\u4e0e\u8bc4\u4ef7\u6807\u51c6\u300b<\/td><td>\u65b0\u98ce\u7cfb\u7edf\u6548\u679c\u8bc4\u4ef7\u4f9d\u636e<\/td><\/tr>\n      <tr><td class=\"text-left\">\u9f99\u8109\u6696\u901a \u00b7 \u6307\u4ee401\uff08\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 V5.0\uff09<\/td><td>\u5185\u90e8\u8bbe\u8ba1\u7ea2\u7ebf\u4e0e\u62a5\u8b66\u89c4\u5219<\/td><\/tr>\n      <tr><td class=\"text-left\">\u9f99\u8109\u6696\u901a \u00b7 \u6307\u4ee402\uff08\u4ea7\u54c1\u4ef7\u683c\u5e93 V5.0\uff09<\/td><td>\u4ea7\u54c1\u9762\u4ef7\u4e0e\u6298\u6263\u6807\u51c6<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:16px;\">\ud83c\udf21 \u6210\u90fd\u5730\u533a\u6c14\u5019\u8bbe\u8ba1\u53c2\u6570<\/h3>\n    <table>\n      <tbody><tr><th>\u53c2\u6570\u9879<\/th><th>\u590f\u5b63\u5236\u51b7<\/th><th>\u51ac\u5b63\u5236\u70ed\/\u91c7\u6696<\/th><\/tr>\n      <tr><td>\u5ba4\u5916\u8bbe\u8ba1\u6e29\u5ea6<\/td><td>32~35\u2103\uff08\u5e72\u7403\uff09<\/td><td>0~2\u2103\uff08\u590f\u70ed\u51ac\u51b7\u5730\u533a\uff09<\/td><\/tr>\n      <tr><td>\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea6<\/td><td>24~26\u2103<\/td><td>20~22\u2103<\/td><\/tr>\n      <tr><td>\u5355\u4f4d\u51b7\/\u70ed\u8d1f\u8377<\/td><td>120~180 W\/\u33a1<\/td><td>60~80 W\/\u33a1\uff08\u5730\u6696\uff09<\/td><\/tr>\n      <tr><td>\u8bbe\u8ba1\u7b56\u7565<\/td><td>\u5feb\u901f\u5236\u51b7+\u9664\u6e7f<\/td><td>\u6301\u7eed\u7a33\u5b9a\u4f4e\u6e29\u4f9b\u70ed<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"info-box\" style=\"margin-top:12px;\">\n      <strong>\ud83d\udca1 \u6210\u90fd\u5730\u533a\u8bbe\u8ba1\u7279\u70b9\uff1a<\/strong>\u6210\u90fd\u5c5e\u5efa\u7b51\u70ed\u5de5\u8bbe\u8ba1\u5206\u533a\u4e2d\u7684<strong>\u590f\u70ed\u51ac\u51b7\u5730\u533a<\/strong>\uff0c\u590f\u5b63\u95f7\u70ed\u6f6e\u6e7f\u9700\u517c\u987e\u9664\u6e7f\uff0c\u51ac\u5b63\u867d\u4e0d\u4e25\u5bd2\u4f46\u6e7f\u5ea6\u5927\u3001\u4f53\u611f\u6e29\u5ea6\u4f4e\uff0c\u5730\u6696\u662f\u63d0\u5347\u51ac\u5b63\u8212\u9002\u5ea6\u7684\u5173\u952e\u914d\u7f6e\u3002\u672c\u65b9\u6848\u7a7a\u8c03\u4e3b\u673a16.0kW\u5236\u51b7\u91cf\u5bf9\u8be5\u6237\u578b\u6709\u5145\u8db3\u4f59\u91cf\uff0c\u5730\u669624kW\u5206\u6bb5\u71c3\u70e7\u9505\u7089\u5728\u6210\u90fd\u6c14\u5019\u4e0b\u53ef\u957f\u671f\u4ee5\u4f4e\u529f\u7387\u6a21\u5f0f\u8fd0\u884c\uff0c\u8282\u80fd\u9ad8\u6548\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:16px;\">\ud83c\udfaf \u5ba2\u6237\u6210\u529f\u6cd5\u5219 \u00b7 \u9700\u6c42\u5c42\u6b21\u9a8c\u8bc1<\/h3>\n    <div style=\"font-size:14px; line-height:2;\">\n      <div style=\"display:flex;align-items:center;gap:8px;padding:6px 0;\">\n        <span class=\"tag green\">\u2713 \u6ee1\u8db3<\/span><strong>\u5b89\u5168\u5c42\uff1a<\/strong>\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u5b89\u88c5\u3001\u56fd\u6807\u65bd\u5de5\u9a8c\u6536\u3001\u963b\u6c27\u5730\u6696\u7ba1\u675c\u7edd\u6c27\u5316\u8150\u8680\n      <\/div>\n      <div style=\"display:flex;align-items:center;gap:8px;padding:6px 0;\">\n        <span class=\"tag green\">\u2713 \u6ee1\u8db3<\/span><strong>\u57fa\u7840\u51b7\u6696\u5c42\uff1a<\/strong>\u8212\u4eab160\u4e3b\u673a16kW\u5f3a\u52b2\u5236\u51b7 + 24kW\u5206\u6bb5\u71c3\u70e7\u9505\u7089\u4fdd\u969c\u6210\u90fd\u51ac\u5b63\n      <\/div>\n      <div style=\"display:flex;align-items:center;gap:8px;padding:6px 0;\">\n        <span class=\"tag green\">\u2713 \u6ee1\u8db3<\/span><strong>\u5065\u5eb7\u8212\u9002\u5c42\uff1a<\/strong>350\u98ce\u91cf\u65b0\u98ce\u7cfb\u7edf\u4e00\u5c0f\u65f6\u5168\u5c4b\u6362\u6c14 + \u5730\u6696\u8db3\u6696\u5934\u51c9\u6700\u4f73\u4f53\u611f\n      <\/div>\n      <div style=\"display:flex;align-items:center;gap:8px;padding:6px 0;\">\n        <span class=\"tag green\">\u2713 \u6ee1\u8db3<\/span><strong>\u8282\u80fd\u7701\u5fc3\u5c42\uff1a<\/strong>DC\u76f4\u6d41\u5185\u673a+\u5206\u6bb5\u71c3\u70e7\u9505\u7089\u7cbe\u51c6\u63a7\u6e29 + 10\u5e74\u80fd\u6e90\u8ddf\u8e2a\uff08B\u7ec4\u53c2\u4e0e\uff09\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s3\">\n  <h2 class=\"section-title\"><span class=\"num\">3<\/span> \u7cfb\u7edf\u65b9\u6848<\/h2>\n\n  <div class=\"system-grid\">\n    <div class=\"system-card\">\n      <div class=\"icon\">\u2744\ufe0f<\/div>\n      <h3>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/h3>\n      <p>\n        <strong>\u65e5\u7acbEX\u8212\u4eab\u7cfb\u5217<\/strong><br>\n        \u5916\u673a\uff1aRAS-160HRNAQ<br>\n        \u5236\u51b7\u91cf 16.0kW \/ \u5236\u70ed\u91cf 18.0kW<br>\n        \u5355\u98ce\u6247\u7d27\u51d1\u8bbe\u8ba1<br>\n        \u652f\u6301-25\u2103\u4f4e\u6e29\u5236\u70ed<br>\n        \u4e00\u62d6\u4e94\u914d\u7f6e | \u8d85\u914d\u7387 114.4%<br>\n        <span class=\"tag blue\">8\u6298\u4f18\u60e0<\/span>\n      <\/p>\n    <\/div>\n    <div class=\"system-card\">\n      <div class=\"icon\">\ud83c\udf2c\ufe0f<\/div>\n      <h3>\u65b0\u98ce\u7cfb\u7edf<\/h3>\n      <p>\n        <strong>\u65e5\u7acb\u4e91\u51c0\u7cfb\u5217<\/strong><br>\n        KPI-3521Q3A\/F<br>\n        \u98ce\u91cf\uff1a350m\u00b3\/h<br>\n        \u8986\u76d6\u4e00\u4e8c\u697c\u5168\u5c4b\u4e94\u623f<br>\n        \u8de8\u5c42\u5b89\u88c5 \u00b7 \u5168\u70ed\u4ea4\u6362<br>\n        \u5168\u70ed\u4ea4\u6362\u56de\u6536\u80fd\u91cf<br>\n        \u9759\u97f3\u8fd0\u884c \u226432dB(A)\n      <\/p>\n    <\/div>\n    <div class=\"system-card\">\n      <div class=\"icon\">\ud83d\udd25<\/div>\n      <h3>\u5730\u6696\u7cfb\u7edf<\/h3>\n      <p>\n        <strong>\u66fc\u745e\u5fb7 + \u9f99\u8109\u8282\u80fd\u7cfb\u7edf<\/strong><br>\n        \u9505\u7089\uff1aLL1PB26-Heidelberg Min.<br>\n        24kW \u5206\u6bb5\u71c3\u70e7\u6280\u672f<br>\n        \u91c7\u6696\u9762\u79ef\uff1a121 \u33a1<br>\n        \u03a620\u963b\u6c27\u5730\u6696\u7ba1<br>\n        169\u5143\/\u33a1 \u8282\u80fd\u7cfb\u7edf\u5305\u5e72<br>\n        <span class=\"tag green\">\u7cfb\u7edf\u8bbe\u8ba1\u5b8c\u5168\u5b9a\u5236<\/span>\n      <\/p>\n    <\/div>\n  <\/div>\n\n  <div class=\"card\" style=\"margin-top:24px;\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\u2744\ufe0f \u7a7a\u8c03\u7cfb\u7edf\u914d\u7f6e\u8be6\u8868<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u5339\u6570<\/th><th>\u5236\u51b7\u91cf(kW)<\/th><th>\u5355\u4f4d\u51b7\u8d1f\u8377(W\/\u33a1)<\/th><\/tr>\n        <tr><td rowspan=\"2\">\u4e00\u697c<\/td><td>\u5ba2\u5385\u9910\u5385<\/td><td>56.36<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>2.8<\/td><td>7.1<\/td><td>126<\/td><\/tr>\n        <tr><td>\u6b21\u5367<\/td><td>9.92<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1.0<\/td><td>2.2<\/td><td>222<\/td><\/tr>\n        <tr><td rowspan=\"3\">\u4e8c\u697c<\/td><td>\u4e3b\u5367<\/td><td>22<\/td><td>RPIZ-36FSNAQD\/P<\/td><td>1.5<\/td><td>3.6<\/td><td>164<\/td><\/tr>\n        <tr><td>\u6b21\u5367<\/td><td>18.2<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1.3<\/td><td>3.2<\/td><td>176<\/td><\/tr>\n        <tr><td>\u4e66\u623f<\/td><td>9.95<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1.0<\/td><td>2.2<\/td><td>221<\/td><\/tr>\n        <tr style=\"font-weight:700;background:#f0f4ff;\"><td colspan=\"4\" class=\"text-left\">\u5185\u673a\u603b\u51b7\u91cf<\/td><td colspan=\"2\">18.3 kW<\/td><td>\u2014<\/td><\/tr>\n        <tr style=\"font-weight:700;background:#fef2f2;\"><td colspan=\"4\" class=\"text-left\">\u5916\u673a\u989d\u5b9a\u5236\u51b7\u91cf\uff08RAS-160HRNAQ\uff09<\/td><td colspan=\"2\">16.0 kW<\/td><td>\u2014<\/td><\/tr>\n        <tr style=\"font-weight:700;\"><td colspan=\"4\" class=\"text-left\">\u8d85\u914d\u7387<\/td><td colspan=\"2\" class=\"highlight\">114.4% \u2713<\/td><td>\u2014<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n    <div class=\"info-box\">\n      <strong>\ud83d\udca1 \u8d85\u914d\u7387\u5206\u6790\uff1a<\/strong>114.4% \u5728\u6c1f\u7cfb\u7edf50%~130%\u5b89\u5168\u533a\u95f4\u5185\uff0c\u8ddd90%~110%\u7406\u60f3\u533a\u95f4\u4ec5\u504f\u5dee4.4%\u3002\u8003\u8651\u5230\u5ba2\u6237\u4e0d\u540c\u623f\u95f4\u7684\u540c\u65f6\u4f7f\u7528\u7387\uff08\u4e66\u623f\u4e0e\u5367\u5ba4\u901a\u5e38\u4e0d\u540c\u65f6\u5168\u5f00\uff09\uff0c\u5b9e\u9645\u8fd0\u884c\u4e2d\u8d85\u914d\u7387\u5c06\u8fdb\u4e00\u6b65\u964d\u4f4e\uff0c\u7cfb\u7edf\u8fd0\u884c\u7a33\u5b9a\u9ad8\u6548\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\" style=\"margin-top:16px;\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83d\udd25 \u5730\u6696\u7cfb\u7edf\u914d\u7f6e\u8be6\u8868<\/h3>\n    <table>\n      <tbody><tr><th>\u914d\u7f6e\u9879<\/th><th>\u53c2\u6570<\/th><th>\u8bf4\u660e<\/th><\/tr>\n      <tr><td>\u9505\u7089\u578b\u53f7<\/td><td class=\"highlight\">LL1PB26-Heidelberg Min.<\/td><td>\u66fc\u745e\u5fb7 \u00b7 \u5206\u6bb5\u71c3\u70e7 24kW<\/td><\/tr>\n      <tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>121 \u33a1<\/td><td>\u542b\u4e8c\u697c\u8fc7\u9053\u5168\u533a\u57df\u8986\u76d6<\/td><\/tr>\n      <tr><td>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/td><td>60~80 W\/\u33a1<\/td><td>\u6210\u90fd\u590f\u70ed\u51ac\u51b7\u5730\u533a\u6807\u51c6\uff0c\u6309121\u33a1\u00d770W\u22488.5kW<\/td><\/tr>\n      <tr><td>\u70ed\u6e90\u529f\u7387\u5339\u914d<\/td><td>24kW \/ 8.5kW = 282%<\/td><td>\u5206\u6bb5\u71c3\u70e7\u6700\u5c0f\u8f93\u51fa\u7ea66kW\uff0c\u53ef\u5339\u914d\u6052\u6e29\u8d1f\u8377<\/td><\/tr>\n      <tr><td>\u7ba1\u5f84<\/td><td>\u03a620 \u963b\u6c27\u7ba1\uff08De20\uff09<\/td><td>\u4e94\u5c42\u963b\u6c27EVOH\u7ba1\u6750\uff0c\u7b26\u5408\u56fd\u6807\u8981\u6c42<\/td><\/tr>\n      <tr><td>\u5e03\u7ba1\u65b9\u5f0f<\/td><td>\u56de\u5b57\u5f62\uff08\u6807\u51c6\u56de\u8def\uff09<\/td><td>\u6bcf\u56de\u8def\u8986\u76d6\u226415\u33a1\uff0c\u5747\u5300\u4f9b\u70ed<\/td><\/tr>\n      <tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7<\/td><td>\u6bcf\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\u9762\u677f + \u7535\u52a8\u6267\u884c\u5668<\/td><\/tr>\n      <tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td class=\"highlight\">\u9f99\u8109\u6696\u901a\u8282\u80fd\u7cfb\u7edf 169\u5143\/\u33a1<\/td><td>\u542b\u6750\u6599+\u4eba\u5de5\u5168\u5305\u5e72\u4ef7<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"warn-box\">\n      <strong>\ud83d\udca1 \u8bbe\u8ba1\u8bf4\u660e\uff1a<\/strong>\u9505\u7089\u989d\u5b9a\u529f\u738724kW\u4e3a\u8bbe\u8ba1\u70ed\u8d1f\u8377\u7684282%\uff0c\u5728\u6210\u90fd\u590f\u70ed\u51ac\u51b7\u5730\u533a\u5c5e\u4e8e\"\u5927\u9505\u7089\u5c0f\u8d1f\u8377\"\u914d\u7f6e\u2014\u2014\u4f46\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u6280\u672f\u53ef\u5c06\u6700\u5c0f\u8f93\u51fa\u964d\u81f3\u7ea66kW\uff0c\u57fa\u672c\u5339\u914d\u6210\u90fd\u51ac\u5b63\u6052\u6e29\u8d1f\u8377\uff08\u7ea65~6kW\uff09\uff0c\u907f\u514d\u9891\u7e41\u542f\u505c\u95ee\u9898\u300224kW\u989d\u5b9a\u529f\u7387\u4e5f\u8db3\u4ee5\u5e94\u5bf9\u751f\u6d3b\u70ed\u6c34\uff08\u5982\u6d74\u7f38\u5feb\u901f\u6ce8\u6c34\u7b49\uff09\u7684\u5cf0\u503c\u9700\u6c42\u3002\u8be5\u914d\u7f6e\u7b26\u5408\u6307\u4ee401\u8bbe\u8ba1\u89c4\u8303\u4e2d\u7684\"\u6700\u63a5\u8fd1\u539f\u5219\"\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\" style=\"margin-top:16px;\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83c\udf2c\ufe0f \u65b0\u98ce\u7cfb\u7edf\u914d\u7f6e\u8be6\u8868<\/h3>\n    <table>\n      <tbody><tr><th>\u914d\u7f6e\u9879<\/th><th>\u53c2\u6570<\/th><\/tr>\n      <tr><td>\u578b\u53f7<\/td><td class=\"highlight\">KPI-3521Q3A\/F\uff08\u65e5\u7acb\u4e91\u51c0\u7cfb\u5217\uff09<\/td><\/tr>\n      <tr><td>\u98ce\u91cf<\/td><td>350 m\u00b3\/h<\/td><\/tr>\n      <tr><td>\u8986\u76d6\u533a\u57df<\/td><td>\u4e00\u697c\u5ba2\u9910\u5385\uff0856.36\u33a1\uff09+ \u6b21\u5367\uff089.92\u33a1\uff09<br>\u4e8c\u697c\u4e3b\u5367\uff0822\u33a1\uff09+ \u6b21\u5367\uff0818.2\u33a1\uff09+ \u4e66\u623f\uff089.95\u33a1\uff09<br>\u5408\u8ba1\u7ea6 116\u33a1 \u00b7 \u8de8\u5c42\u5b89\u88c5<\/td><\/tr>\n      <tr><td>\u6362\u6c14\u6b21\u6570<\/td><td>350 \u00f7 (116\u00d72.8) \u2248 1.07\u6b21\/\u5c0f\u65f6\uff08\u6ee1\u8db3\u56fd\u68070.5\u6b21\/\u5c0f\u65f6\uff09<\/td><\/tr>\n      <tr><td>\u8fc7\u6ee4\u7b49\u7ea7<\/td><td>PM2.5 \u9ad8\u6548\u8fc7\u6ee4 \u226595%<\/td><\/tr>\n      <tr><td>\u70ed\u4ea4\u6362\u65b9\u5f0f<\/td><td>\u5168\u70ed\u4ea4\u6362\u82af\uff0c\u56de\u6536\u6392\u98ce\u80fd\u91cf\uff0c\u8282\u80fd\u8fd0\u884c<\/td><\/tr>\n      <tr><td>\u5b89\u88c5\u4f4d\u7f6e<\/td><td>\u4e00\u697c\u540a\u9876\u5185\uff08\u4e3b\u673a\uff09+ \u7acb\u7ba1\u7a7f\u697c\u677f\u81f3\u4e8c\u697c \u00b7 \u8de8\u5c42\u65bd\u5de5<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"info-box\">\n      <strong>\ud83d\udca1 \u65b0\u98ce\u914d\u7f6e\u903b\u8f91\uff1a<\/strong>\u65b0\u98ce\u91c7\u7528\u8de8\u5c42\u5b89\u88c5\u65b9\u6848\uff0c\u4e00\u53f0350m\u00b3\/h\u4e3b\u673a\u8986\u76d6\u4e00\u697c\u5ba2\u9910\u5385+\u6b21\u5367\u53ca\u4e8c\u697c\u4e09\u4e2a\u5367\u5ba4\u5171\u4e94\u4e2a\u623f\u95f4\uff08\u7ea6116\u33a1\uff09\uff0c\u6362\u6c14\u7387\u7ea61\u6b21\/\u5c0f\u65f6\u6ee1\u8db3\u56fd\u6807\u8981\u6c42\u3002\u8de8\u5c42\u65bd\u5de5\u9700\u589e\u52a0\u7acb\u7ba1\u7a7f\u697c\u677f\u3001\u5bc6\u5c01\u9632\u6c34\u53ca\u4e8c\u697c\u652f\u7ba1\u94fa\u8bbe\u7b49\u989d\u5916\u5de5\u4f5c\u91cf\uff08+\u00a51,500\u8de8\u5c42\u8d39\uff09\u3002\u5168\u70ed\u4ea4\u6362\u82af\u53ef\u56de\u6536\u6392\u98ce\u4e2d\u7ea670%\u7684\u70ed\u91cf\uff0c\u6709\u6548\u964d\u4f4e\u65b0\u98ce\u5bf9\u91c7\u6696\/\u5236\u51b7\u80fd\u8017\u7684\u5f71\u54cd\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card\" style=\"margin-top:16px;\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\ud83d\udd0d \u65b9\u6848\u8bbe\u8ba1\u81ea\u68c0\u9a8c\u8bc1\uff08\u6307\u4ee401 \u00b7 \u6267\u884c\u6b65\u9aa4\uff09<\/h3>\n    <ul class=\"check-list\">\n      <li>\u8d85\u914d\u7387 114.4%\uff0c\u5728 50%~130% \u5b89\u5168\u533a\u95f4\u5185 <span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n      <li>\u8212\u4eab\u5916\u673a RAS-160HRNAQ \u642d\u914d\u8212\u4eabDC\u6807\u51c6\u5185\u673a\uff0c\u7cfb\u5217\u5339\u914d <span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n      <li>\u5730\u6696\u4e3b\u7ba1 De25 \u4ee5\u4e0a\uff0c\u76d8\u7ba1 De20\uff0c\u7ba1\u5f84\u6ee1\u8db3\u6d41\u91cf\u8981\u6c42 <span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n      <li>\u914d\u7f6e\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\u9762\u677f\uff0c\u5b9e\u73b0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236 <span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n      <li>\u9505\u708924kW\u5206\u6bb5\u71c3\u70e7\uff0c\u6700\u5c0f\u8f93\u51fa\u7ea66kW\uff0c\u5339\u914d\u6052\u6e29\u8d1f\u8377 <span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n      <li>\u91c7\u6696\u9762\u79ef121\u33a1 \u2265 80\u33a1\uff0c\u666e\u901a24kW\u9505\u7089\u53ef\u4f7f\u7528\uff08\u975e\u51b7\u51dd\u7089\u62a5\u8b66\u6761\u4ef6\u4e0d\u89e6\u53d1\uff09<span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n      <li>\u5730\u6696\u9009\u7528\u4e94\u5c42\u963b\u6c27EVOH\u7ba1\u6750\uff0c\u672a\u5c40\u90e8\u7701\u7565\u963b\u6c27\u5c42 <span class=\"tag green\">\u2713 \u901a\u8fc7<\/span><\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s4\">\n  <h2 class=\"section-title\"><span class=\"num\">4<\/span> \u8bbe\u5907\u6e05\u5355<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u8bbe\u5907\u6e05\u5355<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">\u5ba4\u5916\u673a<\/td><td class=\"text-left\">RAS-160HRNAQ<\/td><td>\u5236\u51b716.0kW\/\u5236\u70ed18.0kW<\/td><td>1\u53f0<\/td><td>13,775<\/td><\/tr>\n        <tr><td>2<\/td><td class=\"text-left\">\u5ba4\u5185\u673a\uff08\u5ba2\u9910\u5385\uff09<\/td><td class=\"text-left\">RPIZ-71FSNAQD\/P<\/td><td>7.1kW DC\u6807\u51c6\u5185\u673a<\/td><td>1\u53f0<\/td><td>3,513<\/td><\/tr>\n        <tr><td>3<\/td><td class=\"text-left\">\u5ba4\u5185\u673a\uff08\u4e00\u697c\u6b21\u5367\uff09<\/td><td class=\"text-left\">RPIZ-22FSNAQD\/P<\/td><td>2.2kW DC\u6807\u51c6\u5185\u673a<\/td><td>1\u53f0<\/td><td>3,013<\/td><\/tr>\n        <tr><td>4<\/td><td class=\"text-left\">\u5ba4\u5185\u673a\uff08\u4e8c\u697c\u4e3b\u5367\uff09<\/td><td class=\"text-left\">RPIZ-36FSNAQD\/P<\/td><td>3.6kW DC\u6807\u51c6\u5185\u673a<\/td><td>1\u53f0<\/td><td>3,125<\/td><\/tr>\n        <tr><td>5<\/td><td class=\"text-left\">\u5ba4\u5185\u673a\uff08\u4e8c\u697c\u6b21\u5367\uff09<\/td><td class=\"text-left\">RPIZ-32FSNAQD\/P<\/td><td>3.2kW DC\u6807\u51c6\u5185\u673a<\/td><td>1\u53f0<\/td><td>3,100<\/td><\/tr>\n        <tr><td>6<\/td><td class=\"text-left\">\u5ba4\u5185\u673a\uff08\u4e8c\u697c\u4e66\u623f\uff09<\/td><td class=\"text-left\">RPIZ-22FSNAQD\/P<\/td><td>2.2kW DC\u6807\u51c6\u5185\u673a<\/td><td>1\u53f0<\/td><td>3,013<\/td><\/tr>\n        <tr><td>7<\/td><td class=\"text-left\">WiFi\u7ebf\u63a7\u5668<\/td><td class=\"text-left\">PC-P1HVQA<\/td><td>\u767d\u8272\u00b7WiFi\u8054\u52a8<\/td><td>5\u4e2a<\/td><td>200\/\u4e2a<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\u65b0\u98ce\u7cfb\u7edf \u00b7 \u8bbe\u5907\u6e05\u5355<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">\u65b0\u98ce\u4e3b\u673a<\/td><td class=\"text-left\">KPI-3521Q3A\/F<\/td><td>350m\u00b3\/h \u5168\u70ed\u4ea4\u6362<\/td><td>1\u53f0<\/td><td>6,200<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\u5730\u6696\u7cfb\u7edf \u00b7 \u8bbe\u5907\u6e05\u5355<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">\u71c3\u6c14\u58c1\u6302\u7089<\/td><td class=\"text-left\">LL1PB26-Heidelberg Min.<\/td><td>24kW \u5206\u6bb5\u71c3\u70e7<\/td><td>1\u53f0<\/td><td>5,599<\/td><\/tr>\n        <tr><td>2<\/td><td class=\"text-left\">\u5730\u6696\u7cfb\u7edf\uff08\u5305\u5e72\uff09<\/td><td class=\"text-left\">\u9f99\u8109\u6696\u901a\u8282\u80fd\u7cfb\u7edf<\/td><td>169\u5143\/\u33a1 \u00d7 121\u33a1<\/td><td>1\u5957<\/td><td>20,449<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s5\">\n  <h2 class=\"section-title\"><span class=\"num\">5<\/span> \u8f85\u6750\u914d\u7f6e\u6e05\u5355<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\u2744\ufe0f \u7a7a\u8c03\u7cfb\u7edf \u00b7 \u8f85\u6750\u6e05\u5355\uff08\u542b\u5728\u5b89\u88c5\u8d39\u5185\uff09<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u8f85\u6750\u7c7b\u522b<\/th><th>\u54c1\u724c\/\u89c4\u683c<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u51b7\u5a92\u94dc\u7ba1\uff08\u6c14\u7ba1+\u6db2\u7ba1\uff09<\/td><td>\u6d77\u4eae\/\u9f99\u715c R410A\u4e13\u7528<\/td><td>\u542b\u4fdd\u6e29\u68c9\u5305\u88f9\uff0c\u58c1\u539a\u6309\u7ba1\u5f84\u5339\u914d<\/td><\/tr>\n        <tr><td>\u51b7\u51dd\u6c34\u7ba1<\/td><td>\u8054\u5851\/\u516c\u5143 U-PVC<\/td><td>\u542b\u4fdd\u6e29\uff0c\u5761\u5ea6\u22651%<\/td><\/tr>\n        <tr><td>\u5206\u6b67\u7ba1\/\u5206\u6b67\u7bb1<\/td><td>\u65e5\u7acb\u539f\u88c5<\/td><td>Y\u578b\u5206\u6b67\u7ba1\uff0c\u51cf\u5c11\u51b7\u5a92\u504f\u6d41<\/td><\/tr>\n        <tr><td>\u51b7\u5a92 R410A<\/td><td>\u5de8\u5316\/\u675c\u90a6<\/td><td>\u6309\u7ba1\u8def\u957f\u5ea6\u5b9a\u91cf\u5145\u6ce8<\/td><\/tr>\n        <tr><td>\u4fe1\u53f7\u7ebf\/\u7535\u6e90\u7ebf<\/td><td>\u7f8e\u6cb3\/\u8fdc\u4e1c RVVP\u5c4f\u853d\u7ebf<\/td><td>\u542b\u7ebf\u7ba1\uff0c\u72ec\u7acb\u56de\u8def\u4f9b\u7535<\/td><\/tr>\n        <tr><td>\u540a\u6746\/\u652f\u67b6\/\u51cf\u9707\u57ab<\/td><td>\u56fd\u6807\u70ed\u9540\u950c<\/td><td>\u5916\u673a\u51cf\u9707+\u5185\u673a\u540a\u88c5<\/td><\/tr>\n        <tr><td>\u51fa\u98ce\u53e3\/\u56de\u98ce\u53e3<\/td><td>ABS\u53cc\u5c42\u767e\u53f6<\/td><td>\u767d\u8272\uff0c\u542b\u56de\u98ce\u68c0\u4fee\u53e3<\/td><\/tr>\n        <tr><td>\u4fdd\u6e29\u6750\u6599<\/td><td>\u534e\u7f8e\/\u4e16\u9738\u9f99 B1\u7ea7<\/td><td>\u94dc\u7ba1+\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29<\/td><\/tr>\n        <tr><td>\u6c2e\u6c14\u710a\u63a5\u4fdd\u62a4<\/td><td>\u9ad8\u7eaf\u6c2e\u6c14<\/td><td>\u5168\u7a0b\u6c2e\u6c14\u4fdd\u62a4\u710a\uff0c\u9632\u6c27\u5316<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83c\udf2c\ufe0f \u65b0\u98ce\u7cfb\u7edf \u00b7 \u8f85\u6750\u6e05\u5355\uff08\u542b\u5728\u5b89\u88c5\u8d39\u5185\uff09<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u8f85\u6750\u7c7b\u522b<\/th><th>\u54c1\u724c\/\u89c4\u683c<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u65b0\u98ce\u4e3b\u7ba1<\/td><td>\u03a6160 PE\u6ce2\u7eb9\u7ba1\/UPVC<\/td><td>\u542b\u4fdd\u6e29\uff0c\u5ba4\u5916\u6bb5\u9632\u6652\u5904\u7406<\/td><\/tr>\n        <tr><td>\u65b0\u98ce\u652f\u7ba1<\/td><td>\u03a6110 PE\u6ce2\u7eb9\u7ba1<\/td><td>\u81f3\u5404\u9001\/\u6392\u98ce\u53e3<\/td><\/tr>\n        <tr><td>\u9001\u98ce\u53e3\/\u6392\u98ce\u53e3<\/td><td>ABS\u5706\u5f62\/\u65b9\u5f62\u98ce\u53e3<\/td><td>\u542b\u8c03\u8282\u9600\uff0c\u98ce\u91cf\u53ef\u8c03<\/td><\/tr>\n        <tr><td>\u5ba4\u5916\u9632\u96e8\u98ce\u5e3d<\/td><td>\u4e0d\u9508\u94a2+\u9632\u866b\u7f51<\/td><td>\u9632\u96e8\u9632\u866b\uff0c\u65b0\u6392\u98ce\u72ec\u7acb\u8bbe\u7f6e<\/td><\/tr>\n        <tr><td>\u7ba1\u5361\/\u5bc6\u5c01\u80f6<\/td><td>\u56fd\u6807<\/td><td>\u7ba1\u9053\u8fde\u63a5\u5bc6\u5c01<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83d\udd25 \u5730\u6696\u7cfb\u7edf \u00b7 \u8f85\u6750\u6e05\u5355\uff08169\u5143\/\u33a1\u5305\u5e72\u542b\u4ee5\u4e0b\u5168\u90e8\uff09<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u8f85\u6750\u7c7b\u522b<\/th><th>\u54c1\u724c\/\u89c4\u683c<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u5730\u6696\u76d8\u7ba1<\/td><td>\u03a620\u00d72.0 \u4e94\u5c42\u963b\u6c27EVOH\u7ba1<\/td><td>PERT-II\u578b\uff0c\u963b\u6c27\u5c42EVOH<\/td><\/tr>\n        <tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u66fc\u745e\u5fb7 \u4e0d\u9508\u94a2\u953b\u9020<\/td><td>\u542b\u6d41\u91cf\u8ba1+\u8c03\u8282\u9600+\u81ea\u52a8\u6392\u6c14\u9600<\/td><\/tr>\n        <tr><td>\u6e29\u63a7\u9762\u677f<\/td><td>\u66fc\u745e\u5fb7 \u5206\u5ba4\u6db2\u6676\u9762\u677f<\/td><td>\u6bcf\u623f\u95f4\u72ec\u7acb\u63a7\u5236<\/td><\/tr>\n        <tr><td>\u7535\u52a8\u6267\u884c\u5668<\/td><td>\u66fc\u745e\u5fb7 230V\u5e38\u95ed\u578b<\/td><td>\u4e0e\u6e29\u63a7\u9762\u677f\u8054\u52a8<\/td><\/tr>\n        <tr><td>\u6324\u5851\u4fdd\u6e29\u677f<\/td><td>XPS \u226530mm\u539a\uff0c\u5bc6\u5ea6\u226532kg\/m\u00b3<\/td><td>\u5e95\u5c42\u9694\u70ed<\/td><\/tr>\n        <tr><td>\u8fb9\u754c\u4fdd\u6e29\u6761<\/td><td>EVA 8mm\u539a<\/td><td>\u9632\u6b62\u70ed\u91cf\u4fa7\u5411\u6d41\u5931<\/td><\/tr>\n        <tr><td>\u53cd\u5c04\u819c<\/td><td>\u7eaf\u94dd\u65e0\u7eba\u5e03\u590d\u5408\u819c<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n        <tr><td>\u94a2\u4e1d\u7f51<\/td><td>\u03a62.5mm 100\u00d7100mm\u7f51\u683c<\/td><td>\u52a0\u56fa\u627e\u5e73\u5c42<\/td><\/tr>\n        <tr><td>\u5361\u9489\/\u624e\u5e26<\/td><td>\u5c3c\u9f99\u4e13\u7528\u5361\u9489<\/td><td>\u56fa\u5b9a\u76d8\u7ba1<\/td><\/tr>\n        <tr><td>\u4e3b\u7ba1\uff08\u9505\u7089\u2192\u5206\u96c6\u6c34\u5668\uff09<\/td><td>PERT-II De32<\/td><td>\u542b\u4fdd\u6e29\u5957\u7ba1<\/td><\/tr>\n        <tr><td>\u9505\u7089\u5b89\u88c5\u914d\u4ef6<\/td><td>\u70df\u7ba1+\u9600\u95e8+\u8fc7\u6ee4\u5668+\u6cc4\u538b\u9600<\/td><td>\u5168\u5957\u5b89\u88c5\u9644\u4ef6<\/td><\/tr>\n        <tr><td>\u8c46\u77f3\u6df7\u51dd\u571f\u627e\u5e73<\/td><td>C15\u7ec6\u77f3\u6df7\u51dd\u571f 4~5cm<\/td><td>\u8986\u76d6\u76d8\u7ba1\uff0c\u4e00\u6b21\u627e\u5e73<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"info-box\" style=\"margin-top:16px;\">\n    <strong>\ud83d\udca1 \u6307\u4ee406 \u00b7 \u8f85\u6750\u81ea\u52a8\u751f\u6210\u89c4\u5219\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u8f85\u6750\u6e05\u5355\u6309\u9f99\u8109\u6696\u901a\u6307\u4ee406\uff08V2.0\uff09\u89c4\u5219\u81ea\u52a8\u5339\u914d\u751f\u6210\u2014\u2014\u7a7a\u8c03\u7cfb\u7edf\u5bf9\u5e94\u9644\u8868A\uff08\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u8f85\u6750\u6807\u51c6\u914d\u7f6e\uff09\u3001\u65b0\u98ce\u7cfb\u7edf\u5bf9\u5e94\u9644\u8868C\uff08\u65b0\u98ce\u7cfb\u7edf\u8f85\u6750\u6807\u51c6\u914d\u7f6e\uff09\u3001\u5730\u6696\u7cfb\u7edf\u5bf9\u5e94\u9644\u8868D\uff08\u71c3\u6c14\u9505\u7089\u5730\u6696\u7cfb\u7edf\u8f85\u6750\u6807\u51c6\u914d\u7f6e\uff09\u3002\u6240\u6709\u8f85\u6750\u54c1\u724c\u5747\u4e3a\u9f99\u8109\u957f\u671f\u5408\u4f5c\u4f9b\u5e94\u5546\u540d\u5f55\u5185\u54c1\u724c\uff0c\u89c4\u683c\u7b26\u5408\u56fd\u6807\u4e0e\u9f99\u8109\u8bbe\u8ba1\u7ea2\u7ebf\u8981\u6c42\u3002\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s6\">\n  <h2 class=\"section-title\"><span class=\"num\">6<\/span> \u62a5\u4ef7\u660e\u7ec6<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\ud83d\udcca \u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf \u00b7 \u62a5\u4ef7\u660e\u7ec6<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907<\/th><th>\u9762\u4ef7(\u5143)<\/th><th>\u6298\u6263<\/th><th>\u6298\u540e\u4ef7(\u5143)<\/th><th>\u5b89\u88c5\u8d39(\u5143)<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">RAS-160HRNAQ \u5ba4\u5916\u673a<\/td><td>13,775<\/td><td>8\u6298<\/td><td class=\"highlight\">11,020.00<\/td><td>\u5df2\u542b<\/td><td>11,020.00<\/td><\/tr>\n        <tr><td>2<\/td><td class=\"text-left\">RPIZ-71FSNAQD\/P\uff08\u5ba2\u9910\u5385\uff09<\/td><td>3,513<\/td><td>8\u6298<\/td><td class=\"highlight\">2,810.40<\/td><td>1,600<\/td><td>4,410.40<\/td><\/tr>\n        <tr><td>3<\/td><td class=\"text-left\">RPIZ-22FSNAQD\/P\uff08\u4e00\u697c\u6b21\u5367\uff09<\/td><td>3,013<\/td><td>8\u6298<\/td><td class=\"highlight\">2,410.40<\/td><td>1,600<\/td><td>4,010.40<\/td><\/tr>\n        <tr><td>4<\/td><td class=\"text-left\">RPIZ-36FSNAQD\/P\uff08\u4e8c\u697c\u4e3b\u5367\uff09<\/td><td>3,125<\/td><td>8\u6298<\/td><td class=\"highlight\">2,500.00<\/td><td>1,600<\/td><td>4,100.00<\/td><\/tr>\n        <tr><td>5<\/td><td class=\"text-left\">RPIZ-32FSNAQD\/P\uff08\u4e8c\u697c\u6b21\u5367\uff09<\/td><td>3,100<\/td><td>8\u6298<\/td><td class=\"highlight\">2,480.00<\/td><td>1,600<\/td><td>4,080.00<\/td><\/tr>\n        <tr><td>6<\/td><td class=\"text-left\">RPIZ-22FSNAQD\/P\uff08\u4e8c\u697c\u4e66\u623f\uff09<\/td><td>3,013<\/td><td>8\u6298<\/td><td class=\"highlight\">2,410.40<\/td><td>1,600<\/td><td>4,010.40<\/td><\/tr>\n        <tr style=\"background:#f0f4ff;font-weight:600;\">\n          <td colspan=\"5\" class=\"text-left\">\u7a7a\u8c03\u8bbe\u5907\u5c0f\u8ba1\uff08\u6298\u540e+\u542b\u5b89\u88c5\uff09<\/td><td class=\"highlight\">31,631.20<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83c\udf9b \u7ebf\u63a7\u5668<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u6570\u91cf<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">WiFi\u7ebf\u63a7\u5668 PC-P1HVQA<\/td><td>200<\/td><td>5<\/td><td class=\"highlight\">1,000.00<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n    <div class=\"info-box\">\n      <strong>\u53ef\u5347\u7ea7\u9009\u9879\uff1a<\/strong>\u5982\u9700\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668 PC-P1HPQA\uff0c\u00a5476\/\u4e2a\uff0c5\u53f0\u5171 \u00a52,380 \u2014\u2014 \u5347\u7ea7\u8d39\u7528 \u00a51,380\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83c\udf2c\ufe0f \u65b0\u98ce\u7cfb\u7edf \u00b7 \u62a5\u4ef7\u660e\u7ec6<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u5b89\u88c5\u8d39(\u5143)<\/th><th>\u8de8\u5c42\u8d39(\u5143)<\/th><th>\u6570\u91cf<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">KPI-3521Q3A\/F \u65b0\u98ce\u4e3b\u673a<\/td><td>6,200<\/td><td>6,000<\/td><td>1,500<\/td><td>1<\/td><td class=\"highlight\">13,700.00<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83d\udd25 \u5730\u6696\u7cfb\u7edf \u00b7 \u62a5\u4ef7\u660e\u7ec6<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\/\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u6570\u91cf<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr>\n        <tr><td>1<\/td><td class=\"text-left\">LL1PB26-Heidelberg Min. \u9505\u7089<\/td><td>24kW \u5206\u6bb5\u71c3\u70e7<\/td><td>5,599<\/td><td>1\u53f0<\/td><td>5,599.00<\/td><\/tr>\n        <tr><td>2<\/td><td class=\"text-left\">\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>\u542b\u70df\u7ba1+\u914d\u4ef6<\/td><td>600<\/td><td>1<\/td><td>600.00<\/td><\/tr>\n        <tr><td>3<\/td><td class=\"text-left\">\u9f99\u8109\u6696\u901a\u8282\u80fd\u5730\u6696\u7cfb\u7edf<\/td><td>169\u5143\/\u33a1 \u00d7 121\u33a1<\/td><td>169\/\u33a1<\/td><td>121\u33a1<\/td><td class=\"highlight\">20,449.00<\/td><\/tr>\n        <tr style=\"background:#f0f4ff;font-weight:600;\">\n          <td colspan=\"4\" class=\"text-left\">\u5730\u6696\u7cfb\u7edf\u5c0f\u8ba1<\/td><td class=\"highlight\">26,648.00<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n    <div class=\"info-box\">\n      <strong>\ud83d\udca1 \u8282\u80fd\u5730\u6696\u7cfb\u7edf 169\u5143\/\u33a1 \u5305\u542b\uff1a<\/strong>\u03a620\u4e94\u5c42\u963b\u6c27EVOH\u5730\u6696\u76d8\u7ba1 + XPS\u6324\u5851\u4fdd\u6e29\u677f + \u7eaf\u94dd\u53cd\u5c04\u819c + \u94a2\u4e1d\u7f51 + \u8fb9\u754c\u4fdd\u6e29\u6761 + \u5206\u96c6\u6c34\u5668 + \u5206\u5ba4\u6e29\u63a7\u9762\u677f + \u7535\u52a8\u6267\u884c\u5668 + \u4e3b\u7ba1\u9053 + \u5361\u9489\u624e\u5e26 + \u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b\u627e\u5e73 + \u5168\u5957\u65bd\u5de5\u4eba\u5de5\u3002\u4e0d\u542b\u9505\u7089\u3001\u4e0d\u542b\u5929\u7136\u6c14\u7ba1\u9053\u63a5\u5165\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card\" style=\"border-left-color:#f59e0b;\">\n    <h3 style=\"color:#f59e0b;margin-bottom:12px;\">\ud83d\udcca \u5730\u6696\u7cfb\u7edf \u00b7 \u65b9\u6848\u5bf9\u6bd4\u9009\u578b<\/h3>\n    <p style=\"font-size:13px;color:var(--text-light);margin-bottom:16px;\">\n      \u9f99\u8109\u6696\u901a\u4e3a\u5ba2\u6237\u63d0\u4f9b\u4e24\u79cd\u5730\u6696\u7cfb\u7edf\u65b9\u6848\uff0c\u4f9b\u60a8\u6839\u636e\u9884\u7b97\u4e0e\u957f\u671f\u4f7f\u7528\u9700\u6c42\u505a\u51fa\u6700\u4f18\u9009\u62e9\uff1a\n    <\/p>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th style=\"width:18%;\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th style=\"width:41%;background:#1a6b3c;\">\u2b50 \u9f99\u8109\u8282\u80fd\u7cfb\u7edf\uff08\u63a8\u8350\uff09<\/th><th style=\"width:41%;background:#636e72;\">\u5e02\u573a\u7edf\u914d\u7cfb\u7edf<\/th><\/tr>\n        <tr>\n          <td class=\"highlight\">\u5355\u33a1\u4ef7\u683c<\/td>\n          <td class=\"highlight\" style=\"font-size:18px;\">169 \u5143\/\u33a1<\/td>\n          <td style=\"font-size:18px;\">129 \u5143\/\u33a1<\/td>\n        <\/tr>\n        <tr>\n          <td>121\u33a1\u603b\u9020\u4ef7<\/td>\n          <td class=\"highlight\">\u00a520,449<\/td>\n          <td>\u00a515,609<\/td>\n        <\/tr>\n        <tr>\n          <td>\u524d\u671f\u9020\u4ef7\u5dee<\/td>\n          <td colspan=\"2\" style=\"text-align:center;\">\u9f99\u8109\u591a\u6295\u5165 <strong style=\"color:#1a6b3c;\">\u00a54,840<\/strong><\/td>\n        <\/tr>\n        <tr>\n          <td>\u5730\u6696\u76d8\u7ba1<\/td>\n          <td style=\"text-align:left;\">\u03a620\u00d72.0 <strong>\u4e94\u5c42\u963b\u6c27EVOH\u7ba1<\/strong>\uff08PERT-II\u578b\uff09<br>\u963b\u6c27\u5c42\u9632\u6c27\u5316\u8150\u8680\uff0c\u5ef6\u957f\u7cfb\u7edf\u5bff\u547d<\/td>\n          <td style=\"text-align:left;\">\u03a620\u00d72.0 PERT\u666e\u901a\u7ba1<br>\u65e0\u963b\u6c27\u5c42\u6216\u5355\u5c42\u963b\u6c27\uff0c\u957f\u671f\u6613\u6c27\u5316\u7ed3\u57a2<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4fdd\u6e29\u4f53\u7cfb<\/td>\n          <td style=\"text-align:left;\">XPS\u6324\u5851\u677f \u226530mm + \u7eaf\u94dd\u53cd\u5c04\u819c + \u8fb9\u754c\u4fdd\u6e29\u6761<br>\u5411\u4e0b\u70ed\u635f\u5931 \u22645%<\/td>\n          <td style=\"text-align:left;\">XPS\u6324\u5851\u677f 20mm + \u666e\u901a\u53cd\u5c04\u819c<br>\u5411\u4e0b\u70ed\u635f\u5931 10~15%<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5206\u96c6\u6c34\u5668<\/td>\n          <td style=\"text-align:left;\">\u66fc\u745e\u5fb7 \u4e0d\u9508\u94a2\u953b\u9020 \u00b7 \u5e26\u6d41\u91cf\u8ba1+\u8c03\u8282\u9600<\/td>\n          <td style=\"text-align:left;\">\u666e\u901a\u54c1\u724c \u94dc\u8d28\/\u94c1\u8d28 \u00b7 \u7b80\u6613\u624b\u52a8\u9600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6e29\u63a7\u7cfb\u7edf<\/td>\n          <td style=\"text-align:left;\">\u66fc\u745e\u5fb7 \u5206\u5ba4\u6db2\u6676\u9762\u677f + \u7535\u52a8\u6267\u884c\u5668<br>\u6bcf\u623f\u95f4\u72ec\u7acb\u63a7\u6e29<\/td>\n          <td style=\"text-align:left;\">\u57fa\u7840\u673a\u68b0\u6e29\u63a7\u6216\u5355\u70b9\u603b\u63a7<br>\u65e0\u6cd5\u5206\u5ba4\u8c03\u8282<\/td>\n        <\/tr>\n        <tr>\n          <td>\u56de\u586b\u627e\u5e73<\/td>\n          <td style=\"text-align:left;\">\u2714 \u8c46\u77f3\u6df7\u51dd\u571f 4~5cm\uff08\u542b\u4eba\u5de5\uff09<\/td>\n          <td style=\"text-align:left;\">\u9700\u5355\u72ec\u4ed8\u8d39\u6216\u7b80\u6613\u6c34\u6ce5\u6c99\u6d46<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"color:var(--accent);font-weight:700;\">\u540e\u671f\u4f7f\u7528\u8d39<\/td>\n          <td style=\"text-align:left;background:#f0fdf4;\">\u2705 <strong>\u963b\u6c27\u7ba1+\u4f18\u8d28\u4fdd\u6e29<\/strong> \u2192 \u7cfb\u7edf\u6548\u7387\u9ad8<br>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6301\u7eed\u4f18\u5316 \u2192 <strong>\u9010\u5e74\u964d\u4f4e\u80fd\u8017<\/strong><\/td>\n          <td style=\"text-align:left;background:#fef2f2;\">\u274c <strong>\u65e0\u963b\u6c27\u5c42<\/strong> \u2192 3~5\u5e74\u540e\u7ba1\u9053\u7ed3\u57a2\u70ed\u963b\u589e\u52a0<br>\u4fdd\u6e29\u5dee \u2192 \u70ed\u91cf\u4e0b\u4f20 \u2192 <strong>\u80fd\u8017\u9010\u5e74\u4e0a\u5347 15~25%<\/strong><\/td>\n        <\/tr>\n        <tr>\n          <td>\u4f7f\u7528\u5bff\u547d\u5bf9\u6bd4<\/td>\n          <td style=\"text-align:left;background:#f0fdf4;\">\u2705 \u963b\u6c27\u7ba1 <strong>50\u5e74<\/strong>\u5382\u5bb6\u8d28\u4fdd<br>\u5168\u7cfb\u7edf\u8bbe\u8ba1\u5bff\u547d 30\u5e74+<\/td>\n          <td style=\"text-align:left;background:#fef2f2;\">\u274c \u666e\u901a\u7ba1 10~15\u5e74\u5373\u51fa\u73b0\u6548\u7387\u8870\u51cf<br>\u6c27\u5316\u8150\u8680\u53ef\u80fd\u5bfc\u81f4\u63d0\u524d\u66f4\u6362<\/td>\n        <\/tr>\n        <tr>\n          <td>10\u5e74\u603b\u62e5\u6709\u6210\u672c<br><small>(\u521d\u6295\u8d44 + 10\u5e74\u71c3\u6c14\u8d39)<\/small><\/td>\n          <td style=\"text-align:left;background:#f0fdf4;\">\n            <strong>\u521d\u6295\u8d44 \u00a520,449<\/strong><br>\n            10\u5e74\u71c3\u6c14\u8d39\u9884\u4f30 \u00a510,000~14,000<br>\n            \u2248 \u5171\u8ba1 \u00a530,000~34,000\n          <\/td>\n          <td style=\"text-align:left;background:#fef2f2;\">\n            <strong>\u521d\u6295\u8d44 \u00a515,609<\/strong><br>\n            10\u5e74\u71c3\u6c14\u8d39\u9884\u4f30 \u00a513,000~18,000<br>\n            \u2248 \u5171\u8ba1 \u00a528,500~33,500<br>\n            <span style=\"color:#dc2626;font-size:12px;\">(\u9ad8\u80fd\u8017\u573a\u666f\u4e0b\u53ef\u80fd\u53cd\u8d85)<\/span>\n          <\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ef4\u62a4\u6210\u672c<\/td>\n          <td style=\"background:#f0fdf4;\">\u2705 \u51e0\u4e4e\u514d\u7ef4\u62a4\uff08\u963b\u6c27\u7ba1\u4e0d\u7ed3\u57a2\uff09<\/td>\n          <td style=\"background:#fef2f2;\">\u274c \u6bcf3~5\u5e74\u9700\u6e05\u6d17\u7ba1\u8def\uff08\u00a51,500~3,000\/\u6b21\uff09<\/td>\n        <\/tr>\n      <\/tbody><\/table>\n    <\/div>\n    <div class=\"info-box\" style=\"margin-top:16px;\">\n      <strong>\ud83d\udca1 \u9f99\u8109\u5efa\u8bae\uff1a<\/strong>\u5730\u6696\u5c5e\u4e8e\"\u4e00\u6b21\u6295\u8d44\u3001\u957f\u671f\u53d7\u76ca\"\u7684\u9690\u853d\u5de5\u7a0b\uff0c\u65bd\u5de5\u5b8c\u6210\u540e\u65e0\u6cd5\u8f7b\u6613\u66f4\u6362\u3002\u867d\u7136\u9f99\u8109\u8282\u80fd\u7cfb\u7edf\u524d\u671f\u591a\u6295\u5165 \u00a54,840\uff0c\u4f46\u51ed\u501f<strong>\u963b\u6c27\u7ba150\u5e74\u5bff\u547d<\/strong>\u3001<strong>\u4f18\u8d28\u4fdd\u6e29\u964d\u4f4e\u70ed\u635f\u5931<\/strong>\u3001<strong>\u5206\u5ba4\u6e29\u63a7\u7cbe\u51c6\u8282\u80fd<\/strong>\u4e09\u5927\u6838\u5fc3\u4f18\u52bf\uff0c3~5\u5e74\u5185\u5373\u53ef\u901a\u8fc7\u8282\u7701\u7684\u71c3\u6c14\u8d39\u548c\u514d\u7ef4\u62a4\u6210\u672c\u6536\u56de\u5dee\u989d\uff0c\u4e4b\u540e\u6bcf\u5e74\u90fd\u662f\u51c0\u6536\u76ca\u3002\u6210\u90fd\u5730\u533a\u51ac\u5b63\u7ea63~4\u4e2a\u6708\u91c7\u6696\u5b63\uff0c\u957f\u671f\u7d2f\u79ef\u8282\u80fd\u6548\u679c\u540c\u6837\u53ef\u89c2\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"total-box\">\n    <div class=\"total-label\">\u65b9\u6848\u603b\u62a5\u4ef7\uff08\u4e09\u7cfb\u7edf\u96c6\u6210\uff09<\/div>\n    <div class=\"total-amount\">\u00a5 72,979<small style=\"font-size:20px;\">.20<\/small><\/div>\n    <div style=\"font-size:15px;margin-top:12px;\">\n      <div style=\"display:flex;justify-content:center;flex-wrap:wrap;gap:24px;\">\n        <div><span style=\"color:var(--text-light);\">\u7a7a\u8c03\u7cfb\u7edf\uff1a<\/span><strong>\u00a531,631.20<\/strong><\/div>\n        <div><span style=\"color:var(--text-light);\">\u7ebf\u63a7\u5668\uff1a<\/span><strong>\u00a51,000.00<\/strong><\/div>\n        <div><span style=\"color:var(--text-light);\">\u65b0\u98ce\u7cfb\u7edf\uff1a<\/span><strong>\u00a513,700.00<\/strong><\/div>\n        <div><span style=\"color:var(--text-light);\">\u5730\u6696\u7cfb\u7edf\uff1a<\/span><strong>\u00a526,648.00<\/strong><\/div>\n      <\/div>\n    <\/div>\n    <div class=\"total-note\">\n      * \u4ee5\u4e0a\u4ef7\u683c\u4e3a\u9762\u4ef7\u00d78\u6298\uff08\u8212\u4eab\u7cfb\u5217\uff09\u540e\u7684\u6298\u540e\u4ef7 + \u5b89\u88c5\u8d39 + \u5730\u6696169\u5143\/\u33a1\u5305\u5e72\u4ef7<br>\n      * \u65b0\u98ce\u542b\u8de8\u5c42\u5b89\u88c5\u9644\u52a0\u8d39 \u00a51,500\uff08\u7acb\u7ba1\u7a7f\u697c\u677f + \u4e8c\u697c\u652f\u7ba1\u94fa\u8bbe + \u5bc6\u5c01\u9632\u6c34\uff09<br>\n      * \u62a5\u4ef7\u6309\u9f99\u8109\u6696\u901a\u6307\u4ee402\uff08V5.0\uff09\u4ef7\u683c\u5e93\u6807\u51c6\uff0c2024\u5e748\u6708\u8d77\u6267\u884c<br>\n      * \u6700\u7ec8\u6210\u4ea4\u4ef7\u683c\u4ee5\u5408\u540c\u4e3a\u51c6\uff0c\u672c\u62a5\u4ef7\u4e66\u6709\u6548\u671f30\u5929\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s7\">\n  <h2 class=\"section-title\"><span class=\"num\">7<\/span> \u65bd\u5de5\u670d\u52a1<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:16px;\">\ud83c\udfd7 \u65bd\u5de5\u6d41\u7a0b \u00b7 \u516d\u5927\u6b65\u9aa4<\/h3>\n    <div class=\"step-flow\">\n      <div class=\"step-item\"><div class=\"step-num\">\u2460<\/div><div class=\"step-label\">\u4e0a\u95e8\u52d8\u6d4b<br>\u8d1f\u8377\u8ba1\u7b97<\/div><\/div>\n      <div class=\"step-item\"><div class=\"step-num\">\u2461<\/div><div class=\"step-label\">\u65b9\u6848\u786e\u8ba4<br>\u7b7e\u7ea6\u6392\u671f<\/div><\/div>\n      <div class=\"step-item\"><div class=\"step-num\">\u2462<\/div><div class=\"step-label\">\u6c34\u7535\u4ea4\u5e95<br>\u7ba1\u8def\u9884\u57cb<\/div><\/div>\n      <div class=\"step-item\"><div class=\"step-num\">\u2463<\/div><div class=\"step-label\">\u8bbe\u5907\u5b89\u88c5<br>\u7ba1\u8def\u8fde\u63a5<\/div><\/div>\n      <div class=\"step-item\"><div class=\"step-num\">\u2464<\/div><div class=\"step-label\">\u7cfb\u7edf\u8c03\u8bd5<br>\u538b\u529b\u6d4b\u8bd5<\/div><\/div>\n      <div class=\"step-item\"><div class=\"step-num\">\u2465<\/div><div class=\"step-label\">\u4ea4\u4ed8\u9a8c\u6536<br>\u4f7f\u7528\u57f9\u8bad<\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83d\udd27 \u5173\u952e\u65bd\u5de5\u5de5\u827a\u627f\u8bfa<\/h3>\n    <ul class=\"star-list\">\n      <li><strong>\u5168\u7a0b\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff1a<\/strong>\u94dc\u7ba1\u710a\u63a5\u5168\u8fc7\u7a0b\u901a\u6c2e\u6c14\u9632\u6c27\u5316\uff0c\u675c\u7edd\u710a\u6e23\u5835\u585e\u7ba1\u8def<\/li>\n      <li><strong>\u4fdd\u538b\u68c0\u6f0f\uff1a<\/strong>\u7a7a\u8c03\u7cfb\u7edf4.0MPa\u6c2e\u6c14\u4fdd\u538b24\u5c0f\u65f6\u65e0\u538b\u964d\uff1b\u5730\u6696\u7cfb\u7edf0.6MPa\u6c34\u538b\u8bd5\u9a8c\u5408\u683c<\/li>\n      <li><strong>\u62bd\u771f\u7a7a\u5e72\u71e5\uff1a<\/strong>\u51b7\u5a92\u7ba1\u8def\u771f\u7a7a\u5ea6\u2264100Pa\uff0c\u5e72\u71e5\u5904\u7406\u540e\u65b9\u5145\u6ce8\u51b7\u5a92<\/li>\n      <li><strong>\u51b7\u51dd\u6c34\u6d4b\u8bd5\uff1a<\/strong>\u6240\u6709\u5185\u673a\u901a\u6c34\u8bd5\u9a8c\uff0c\u786e\u4fdd\u6392\u6c34\u901a\u7545\u65e0\u6e17\u6f0f<\/li>\n      <li><strong>\u5730\u6696\u56de\u586b\u517b\u62a4\uff1a<\/strong>\u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b\u540e\u6d12\u6c34\u517b\u62a47\u5929\uff0c\u9632\u6b62\u5f00\u88c2<\/li>\n      <li><strong>\u9505\u7089\u8c03\u8bd5\uff1a<\/strong>\u71c3\u6c14\u538b\u529b\u68c0\u6d4b + \u71c3\u70e7\u6548\u7387\u6d4b\u8bd5 + CO\u6392\u653e\u68c0\u6d4b<\/li>\n      <li><strong>\u65b0\u98ce\u98ce\u91cf\u5e73\u8861\uff1a<\/strong>\u9010\u98ce\u53e3\u6d4b\u98ce\u901f\uff0c\u786e\u4fdd\u8bbe\u8ba1\u98ce\u91cf\u504f\u5dee\u226410%<\/li>\n    <\/ul>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83d\udcc5 \u9884\u4f30\u5de5\u671f<\/h3>\n    <table>\n      <tbody><tr><th>\u65bd\u5de5\u9636\u6bb5<\/th><th>\u5de5\u671f<\/th><th>\u5173\u952e\u8282\u70b9<\/th><\/tr>\n      <tr><td>\u7a7a\u8c03\u7ba1\u8def\u9884\u57cb<\/td><td>2~3\u5929<\/td><td>\u6c34\u7535\u9636\u6bb5\u540c\u6b65\u8fdb\u884c<\/td><\/tr>\n      <tr><td>\u65b0\u98ce\u7ba1\u8def\u9884\u57cb<\/td><td>1~2\u5929<\/td><td>\u540a\u9876\u5c01\u677f\u524d\u5b8c\u6210<\/td><\/tr>\n      <tr><td>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe<\/td><td>2~3\u5929<\/td><td>\u5730\u9762\u627e\u5e73\u524d\u5b8c\u6210<\/td><\/tr>\n      <tr><td>\u5730\u6696\u56de\u586b\u517b\u62a4<\/td><td>7\u5929<\/td><td>\u517b\u62a4\u671f\u4e0d\u53ef\u4e0a\u4eba<\/td><\/tr>\n      <tr><td>\u8bbe\u5907\u5b89\u88c5\uff08\u5916\u673a+\u5185\u673a+\u65b0\u98ce\u4e3b\u673a+\u9505\u7089\uff09<\/td><td>2~3\u5929<\/td><td>\u88c5\u4fee\u540e\u671f\u7edf\u4e00\u5b89\u88c5<\/td><\/tr>\n      <tr><td>\u7cfb\u7edf\u8c03\u8bd5+\u9a8c\u6536<\/td><td>1~2\u5929<\/td><td>\u6c34\u7535\u71c3\u6c14\u63a5\u901a\u540e<\/td><\/tr>\n      <tr style=\"font-weight:700;background:#f0f4ff;\"><td colspan=\"2\" class=\"text-left\">\u7d2f\u8ba1\u65bd\u5de5\u5de5\u671f\uff08\u4e0d\u542b\u88c5\u4fee\u95f4\u6b47\uff09<\/td><td>\u7ea6 15~20 \u4e2a\u5de5\u4f5c\u65e5<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s8\">\n  <h2 class=\"section-title\"><span class=\"num\">8<\/span> \u552e\u540e\u4fdd\u969c<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:16px;\">\ud83d\udee1 \u8d28\u4fdd\u671f\u9650 \u00b7 \u4e09\u7cfb\u7edf\u5206\u522b\u627f\u8bfa<\/h3>\n    <table>\n      <tbody><tr><th>\u7cfb\u7edf<\/th><th>\u8bbe\u5907\/\u90e8\u4ef6<\/th><th>\u8d28\u4fdd\u671f\u9650<\/th><th>\u8d28\u4fdd\u8303\u56f4<\/th><\/tr>\n      <tr><td>\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u65e5\u7acbEX\u8212\u4eab\u5916\u673a+\u5185\u673a<\/td><td class=\"highlight\">\u6574\u673a5\u5e74<\/td><td>\u538b\u7f29\u673a\u3001\u7535\u673a\u3001\u7535\u63a7\u677f\u7b49\u5168\u90e8\u5668\u4ef6<\/td><\/tr>\n      <tr><td>\u65b0\u98ce\u7cfb\u7edf<\/td><td>\u65e5\u7acb\u4e91\u51c0KPI-3521Q3A\/F<\/td><td class=\"highlight\">\u6574\u673a3\u5e74<\/td><td>\u7535\u673a\u3001\u70ed\u4ea4\u6362\u82af\u3001\u7535\u63a7\u6a21\u5757<\/td><\/tr>\n      <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u66fc\u745e\u5fb7\u9505\u7089 LL1PB26<\/td><td class=\"highlight\">\u6574\u673a3\u5e74<\/td><td>\u71c3\u70e7\u5668\u3001\u6c34\u6cf5\u3001\u677f\u6362\u3001\u7535\u63a7<\/td><\/tr>\n      <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u9f99\u8109\u65bd\u5de5\u00b7\u5730\u6696\u76d8\u7ba1<\/td><td class=\"highlight\">\u76d8\u7ba150\u5e74<\/td><td>\u4e94\u5c42\u963b\u6c27EVOH\u7ba1\u6750\uff08\u5382\u5bb6\u8d28\u4fdd\uff09<\/td><\/tr>\n      <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u9f99\u8109\u65bd\u5de5\u00b7\u8f85\u6750\u4e0e\u5b89\u88c5<\/td><td class=\"highlight\">5\u5e74<\/td><td>\u5206\u96c6\u6c34\u5668\u3001\u6267\u884c\u5668\u3001\u6e29\u63a7\u9762\u677f<\/td><\/tr>\n      <tr><td>\u5b89\u88c5\u5de5\u7a0b<\/td><td>\u9f99\u8109\u6696\u901a \u00b7 \u5b89\u88c5\u4eba\u5de5<\/td><td class=\"highlight\">5\u5e74<\/td><td>\u94dc\u7ba1\u710a\u63a5\u3001\u51b7\u5a92\u7ba1\u8def\u3001\u6392\u6c34\u7ba1\u8def\u7b49<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83d\udd04 \u53c2\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u540e \u00b7 \u8d28\u4fdd\u5347\u7ea7<\/h3>\n    <div class=\"table-wrap\">\n      <table>\n        <tbody><tr><th>\u539f\u8d28\u4fdd<\/th><th>B\u7ec4\uff08\u63a8\u8350\uff09\u5347\u7ea7\u540e<\/th><\/tr>\n        <tr><td>\u9f99\u8109\u65bd\u5de5\u90e8\u5206 5\u5e74<\/td><td class=\"highlight\">\u5168\u7cfb\u7edf 5\u5e74 \u2192 \u5165\u4f1a\u5ef6\u81f3 10\u5e74<\/td><\/tr>\n        <tr><td>\u65e0\u80fd\u8017\u8ddf\u8e2a<\/td><td class=\"highlight\">\u514d\u8d39\u8054\u52a8\u63a7\u5236\u5668 + 10\u5e74\u80fd\u6e90\u8ddf\u8e2a\u62a5\u544a<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n    <div style=\"font-size:14px;margin-top:12px;color:var(--text-light);\">\n      * \u8be6\u89c1\u7b2c9\u8282\u300c10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u300d\uff0c\u5efa\u8bae\u5ba2\u6237\u9009\u62e9<strong>B\u7ec4\uff08\u5b9e\u9a8c\u7ec4\uff09<\/strong>\u53c2\u4e0e\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83d\udcde \u552e\u540e\u54cd\u5e94<\/h3>\n    <ul class=\"star-list\">\n      <li><strong>24\u5c0f\u65f6\u54cd\u5e94\uff1a<\/strong>\u63a5\u5230\u62a5\u4fee\u540e24\u5c0f\u65f6\u5185\u54cd\u5e94\uff0c48\u5c0f\u65f6\u5185\u4e0a\u95e8<\/li>\n      <li><strong>\u91c7\u6696\u5b63\u4f18\u5148\uff1a<\/strong>\u6bcf\u5e7410\u6708~\u6b21\u5e744\u6708\u91c7\u6696\u5b63\uff0c\u552e\u540e\u7eff\u8272\u901a\u9053\u4f18\u5148\u5904\u7406<\/li>\n      <li><strong>\u5e74\u5ea6\u5de1\u68c0\uff1a<\/strong>\u6bcf\u5e74\u514d\u8d39\u4e0a\u95e8\u5de1\u68c0\u4e00\u6b21\uff08\u542b\u8fc7\u6ee4\u7f51\u6e05\u6d17\u3001\u51b7\u5a92\u538b\u529b\u68c0\u6d4b\u3001\u9505\u7089\u71c3\u70e7\u68c0\u6d4b\uff09<\/li>\n      <li><strong>\u5907\u4ef6\u4fdd\u969c\uff1a<\/strong>\u6210\u90fd\u4ed3\u5e93\u5907\u6709\u65e5\u7acb+\u66fc\u745e\u5fb7\u5e38\u7528\u914d\u4ef6\uff0c\u7d27\u6025\u4ef648\u5c0f\u65f6\u5230\u4f4d<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s9\">\n  <h2 class=\"section-title\"><span class=\"num\">9<\/span> 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\u26a1 \u9f99\u8109\u6696\u901a \u00b7 \u5730\u669610\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff08V3.0\uff09<\/h3>\n    <p style=\"font-size:14px;color:var(--text-light);margin-bottom:16px;\">\n      \u9f99\u8109\u6696\u901a2004\u5e74\u6210\u7acb\uff0c22\u5e74\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf\u3002\u8fd9\u4e0d\u662f\u8425\u9500\u6d3b\u52a8\uff0c\u800c\u662f\u5199\u5165\u5ba2\u6237\u6863\u6848\u7684<strong>10\u5e74\u670d\u52a1\u627f\u8bfa<\/strong>\u3002\n      \u53c2\u4e0e\u8005\u6210\u4e3a\"\u8282\u80fd\u7814\u7a76\u8005\"\uff0c\u6bcf\u5e74\u81ea\u52a8\u91c7\u96c6\u80fd\u8017\u6570\u636e\u3001\u751f\u6210\u5206\u6790\u62a5\u544a\uff0c\u7528\u6570\u636e\u9a8c\u8bc1\u7cfb\u7edf\u771f\u5b9e\u8282\u80fd\u6548\u679c\u3002\n    <\/p>\n\n    <table>\n      <tbody><tr><th>\u7ec4\u522b<\/th><th>\u6838\u5fc3\u6807\u51c6<\/th><th>\u6838\u5fc3\u6743\u76ca<\/th><th style=\"width:60px;\">\u63a8\u8350<\/th><\/tr>\n      <tr>\n        <td><strong>A\u7ec4<\/strong><br>\u5bf9\u7167\u7ec4<\/td>\n        <td>\u90e8\u5206\u8ba4\u53ef\u9f99\u8109\u8bbe\u8ba1\uff0c\u6709\u81ea\u5df1\u60f3\u6cd5\uff08\u5982\u5df2\u6709\u5fc3\u4eea\u9505\u7089\u54c1\u724c\uff09<\/td>\n        <td style=\"text-align:left;\">\u9f99\u8109\u65bd\u5de5\u90e8\u52065\u5e74\u2192\u5165\u4f1a\u5ef6\u81f310\u5e74<br>\u5e74\u5ea6\u7528\u6c14\u91cf+\u540c\u6237\u578b\u5bf9\u6807<\/td>\n        <td><\/td>\n      <\/tr>\n      <tr style=\"background:#fef3c7;\">\n        <td><strong>B\u7ec4<\/strong><br>\u5b9e\u9a8c\u7ec4<\/td>\n        <td>\u5b8c\u5168\u8ba4\u53ef\u9f99\u8109\u7cfb\u7edf\u8bbe\u8ba1\uff0c\u4fe1\u4efb\u9f99\u810922\u5e74\u7ecf\u9a8c<\/td>\n        <td style=\"text-align:left;\">\u5168\u7cfb\u7edf5\u5e74\u2192\u5165\u4f1a\u5ef6\u81f3<strong>10\u5e74<\/strong><br>\u9505\u7089\u5ba2\u6237\uff1a<strong>\u514d\u8d39\u8054\u52a8\u63a7\u5236\u5668<\/strong><br>\u5e74\u5ea6\u80fd\u8017\u5206\u6790\u62a5\u544a+\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae<br>6\u7ef4\u8ffd\u8e2a\uff1a\u8fd0\u884c\u8d39\/\u7ef4\u62a4\u8d39\/\u5bff\u547d\/\u7a33\u5b9a\u6027\/\u8212\u9002\u5ea6\/\u521d\u6295\u8d44<\/td>\n        <td><span class=\"tag red\">\u2b50\u63a8\u8350<\/span><\/td>\n      <\/tr>\n    <\/tbody><\/table>\n\n    <div class=\"info-box\" style=\"margin-top:16px;\">\n      <strong>\ud83d\udca1 \u63a8\u8350B\u7ec4\u7684\u7406\u7531\uff1a<\/strong>\u672c\u9879\u76ee\u91c7\u7528\u9f99\u8109\u6696\u901a\u8282\u80fd\u5730\u6696\u7cfb\u7edf\uff08169\u5143\/\u33a1\uff09\uff0c\u914d\u5408\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u9505\u7089\uff0c\u7cfb\u7edf\u8bbe\u8ba1\u5b8c\u5168\u7531\u9f99\u8109\u56e2\u961f\u4e3b\u5bfc\uff0c\u975e\u5e38\u9002\u5408\u53c2\u4e0eB\u7ec4\u5b9e\u9a8c\u2014\u2014\u53ef\u4ee5\u83b7\u5f97<strong>\u514d\u8d39\u8054\u52a8\u63a7\u5236\u5668<\/strong>\uff08\u5b9e\u73b0\u9505\u7089\u4e0e\u5ba4\u6e29\u7684\u667a\u80fd\u8054\u52a8\uff09\uff0c\u4eab\u53d7<strong>10\u5e74\u5168\u7cfb\u7edf\u8d28\u4fdd<\/strong>\uff0c\u4ee5\u53ca\u6bcf\u5e74\u4e13\u5c5e\u7684\u80fd\u8017\u5206\u6790\u62a5\u544a\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83d\udcc5 10\u5e74\u8ddf\u8e2a\u56db\u9636\u6bb5<\/h3>\n    <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:16px;\">\n      <div style=\"text-align:center;padding:16px;background:#f0f4ff;border-radius:8px;\">\n        <div style=\"font-size:28px;font-weight:800;color:var(--primary);\">\u7b2c1\u5e74<\/div>\n        <div style=\"font-size:14px;color:var(--text-light);margin-top:6px;\">\u57fa\u51c6\u5efa\u7acb\u671f<br>\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848<\/div>\n      <\/div>\n      <div style=\"text-align:center;padding:16px;background:#f0fdf4;border-radius:8px;\">\n        <div style=\"font-size:28px;font-weight:800;color:#16a34a;\">\u7b2c3\u5e74<\/div>\n        <div style=\"font-size:14px;color:var(--text-light);margin-top:6px;\">\u6548\u679c\u9a8c\u8bc1\u671f<br>3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a<\/div>\n      <\/div>\n      <div style=\"text-align:center;padding:16px;background:#fffbeb;border-radius:8px;\">\n        <div style=\"font-size:28px;font-weight:800;color:#f59e0b;\">\u7b2c5\u5e74<\/div>\n        <div style=\"font-size:14px;color:var(--text-light);margin-top:6px;\">\u6df1\u5ea6\u89e3\u6790\u671f<br>\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad<\/div>\n      <\/div>\n      <div style=\"text-align:center;padding:16px;background:#fef2f2;border-radius:8px;\">\n        <div style=\"font-size:28px;font-weight:800;color:var(--accent);\">\u7b2c10\u5e74<\/div>\n        <div style=\"font-size:14px;color:var(--text-light);margin-top:6px;\">\u627f\u8bfa\u5151\u73b0\u671f<br>10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83d\udcdd \u56db\u5927\u6838\u5fc3\u627f\u8bfa<\/h3>\n    <ul class=\"star-list\">\n      <li><strong>\u627f\u8bfa\u4e00\uff1a<\/strong>\u6bcf\u5e74\u51fa\u5177\u4e00\u4efd\u4e13\u5c5e\u80fd\u8017\u5206\u6790\u62a5\u544a + \u7cfb\u7edf\u4f18\u5316\u5efa\u8bae<\/li>\n      <li><strong>\u627f\u8bfa\u4e8c\uff1a<\/strong>\u56e0\u7cfb\u7edf\u8bbe\u8ba1\u6216\u65bd\u5de5\u7f3a\u9677\u5bfc\u81f4\u7684\u95ee\u9898\u2014\u2014\u514d\u8d39\u4f18\u5316\u6539\u9020\uff08\u6392\u9664\u7528\u6237\u4f7f\u7528\u4e0d\u5f53\uff09<\/li>\n      <li><strong>\u627f\u8bfa\u4e09\uff1a<\/strong>10\u5e74\u5168\u7a0b\u8ddf\u8e2a\u670d\u52a1\uff1b\u76d8\u7ba150\u5e74\u5382\u5bb6\u8d28\u4fdd\uff1b\u9505\u7089\u7b2c9\u5e74\u4e3b\u52a8\u63d0\u9192\u66f4\u6362<\/li>\n      <li><strong>\u627f\u8bfa\u56db\uff1a<\/strong>10\u5e74\u671f\u6ee1\u540e\uff0c\u7ee7\u7eed\u63d0\u4f9b20\u5e74\u552e\u540e\u7ef4\u4fdd\u670d\u52a1<\/li>\n    <\/ul>\n    <div style=\"font-size:13px;color:var(--text-light);margin-top:12px;\">\n      <strong>\u4e0d\u5c5e\u4e8e\u7cfb\u7edf\u539f\u56e0\u7684\u4f8b\u5916\uff1a<\/strong>\u957f\u671f\u5f00\u7a97\u901a\u98ce \/ \u5ba4\u6e29\u8bbe\u7f6e\u8d85\u8fc722\u2103 \/ \u672a\u6309\u8981\u6c42\u7ef4\u62a4\u4fdd\u517b \/ \u623f\u5c4b\u4fdd\u6e29\u6761\u4ef6\u53d1\u751f\u91cd\u5927\u53d8\u5316<br>\n      <strong>\u6570\u636e\u9690\u79c1\uff1a<\/strong>\u4e0d\u516c\u5f00\u3001\u4e0d\u6bd4\u8f83\u3001\u4e0d\u8bc4\u5224\u3002\u5ba2\u6237\u6570\u636e\u8131\u654f\u7f16\u7801\u5904\u7406\uff08\u5982 B-B-CD-01\uff09\uff0c\u4e0d\u613f\u5171\u4eab\u8005\u53ef\u7b7e\u4fdd\u5bc6\u534f\u8bae\u3002\n    <\/div>\n  <\/div>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:12px;\">\u2705 \u53c2\u4e0e\u6b65\u9aa4<\/h3>\n    <ol style=\"font-size:14px;line-height:2;padding-left:20px;\">\n      <li>\u7b7e\u7ea6\u65f6\u5411\u65b9\u6848\u987e\u95ee\u786e\u8ba4\u53c2\u4e0e\u300c10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u300d<\/li>\n      <li>\u7b7e\u7f72\u300a10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u786e\u8ba4\u4e66\u300b\uff08\u4e00\u5f0f\u4e24\u4efd\uff0c\u5ba2\u6237\u4e0e\u9f99\u8109\u5404\u6267\u4e00\u4efd\uff09<\/li>\n      <li>\u786e\u8ba4\u4e66\u626b\u63cf\u4ef6\u5b58\u5165\u5ba2\u6237\u4e13\u5c5e\u6863\u6848\uff0c\u4eab\u7ec8\u8eab\u670d\u52a1\u8ffd\u8e2a<\/li>\n    <\/ol>\n  <\/div>\n<\/div>\n\n<div class=\"section\" id=\"s10\">\n  <h2 class=\"section-title\"><span class=\"num\">10<\/span> \u8054\u7cfb\u6211\u4eec<\/h2>\n\n  <div class=\"card\">\n    <h3 style=\"color:var(--primary);margin-bottom:16px;\">\ud83c\udfe2 \u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546<\/h3>\n    <table>\n      <tbody><tr><td style=\"font-weight:600;width:120px;\">\u6210\u7acb\u65f6\u95f4<\/td><td>2004\u5e74\uff0c22\u5e74\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u6388\u6743\u8d44\u8d28<\/td><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546 | \u66fc\u745e\u5fb7 \u00b7 \u6388\u6743\u670d\u52a1\u5546<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u670d\u52a1\u533a\u57df<\/td><td>\u6210\u90fd\u5e02\u53ca\u5468\u8fb9\uff0c\u65b0\u7586\u5730\u533a\u53ef\u627f\u63a5\uff08\u9700\u786e\u8ba4\u5177\u4f53\u57ce\u5e02\uff09<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card accent-left\">\n    <h3 style=\"color:var(--accent);margin-bottom:12px;\">\ud83d\udccd \u95e8\u5e97\u4fe1\u606f<\/h3>\n    <div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;\">\n      <div style=\"padding:16px;background:var(--bg-light);border-radius:8px;\">\n        <h4 style=\"color:var(--primary);\">\ud83c\udfea \u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97<\/h4>\n        <div style=\"font-size:13px;color:var(--text-light);\">\n          \u7535\u8bdd\uff1a028-86131795<br>\n          \u8303\u4e3d\u5982\uff1a13398198375<br>\n          \u90ed\u52c7\u79c0\uff1a18100839248<br>\n          \u4f59\u6653\u73b2\uff1a13908183204\n        <\/div>\n      <\/div>\n      <div style=\"padding:16px;background:var(--bg-light);border-radius:8px;\">\n        <h4 style=\"color:var(--primary);\">\ud83c\udfea \u5317\u5bcc\u68ee\u6210\u534e\u5e97<\/h4>\n        <div style=\"font-size:13px;color:var(--text-light);\">\n          \u7535\u8bdd\uff1a028-65272586<br>\n          \u9ec4\u52c7\uff1a15828489188<br>\n          \u9b4f\u767e\u6210\uff1a18100839248<br>\n          \u4f59\u7231\u82f1\uff1a13908183204\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"card gold-left\">\n    <h3 style=\"color:var(--gold);margin-bottom:12px;\">\ud83c\udf10 \u5728\u7ebf\u4e86\u89e3<\/h3>\n    <div style=\"font-size:14px;line-height:2;\">\n      <div>\u5b98\u65b9\u7f51\u7ad9\uff1a<a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" style=\"color:var(--primary);\">https:\/\/longmai-nt.com<\/a><\/div>\n      <div>\u65b9\u6848\u5185\u5bb9\u542b\uff1a\u4e2d\u592e\u7a7a\u8c03 \/ \u5730\u6696 \/ \u65b0\u98ce \/ \u51c0\u6c34 \/ \u70ed\u6c34 \u4e94\u5927\u8212\u9002\u7cfb\u7edf<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"footer\">\n  <strong>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546<\/strong><br>\n  2004-2026 \u00b7 22\u5e74\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf<br>\n  \u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff1a028-86131795 | \u5317\u5bcc\u68ee\u6210\u534e\u5e97\uff1a028-65272586<br>\n  \u5b98\u7f51\uff1a<a href=\"https:\/\/longmai-nt.com\">longmai-nt.com<\/a><br>\n  <br>\n  \u672c\u65b9\u6848\u62a5\u4ef7\u4e66\u751f\u6210\u65f6\u95f4\uff1a2026\u5e747\u67081\u65e5 | \u6709\u6548\u671f30\u5929<br>\n  \u00a9 2026 \u9f99\u8109\u6696\u901a \u7248\u6743\u6240\u6709\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>HITACHI \u00b7 \u9f99\u8109\u6696\u901a \u5b98\u65b9\u6388\u6743\u7ecf [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-5042","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=5042\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"HITACHI \u00b7 \u9f99\u8109\u6696\u901a \u5b98\u65b9\u6388\u6743\u7ecf [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=5042\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-22T04:19:28+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5042\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5042\",\"name\":\"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-07-01T14:33:24+00:00\",\"dateModified\":\"2026-10-22T04:19:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5042#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5042\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5042#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=5042","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"HITACHI \u00b7 \u9f99\u8109\u6696\u901a \u5b98\u65b9\u6388\u6743\u7ecf [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=5042","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-22T04:19:28+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"7 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=5042","url":"https:\/\/longmai-nt.com\/?page_id=5042","name":"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-07-01T14:33:24+00:00","dateModified":"2026-10-22T04:19:28+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=5042#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=5042"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=5042#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u62a5\u4ef7\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5042","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5042"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5042\/revisions"}],"predecessor-version":[{"id":16112,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5042\/revisions\/16112"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}