{"id":5462,"date":"2026-07-04T19:32:37","date_gmt":"2026-07-04T11:32:37","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=5462"},"modified":"2026-07-05T14:24:04","modified_gmt":"2026-07-05T06:24:04","slug":"%e5%bc%a0%e5%a5%b3%e5%a3%ab-%c2%b7-%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e7%b3%bb%e5%88%97%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e9%80%89%e8%b4%ad%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=5462","title":{"rendered":"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848"},"content":{"rendered":"<p><!DOCTYPE html><br \/>\n<html lang=\"zh-CN\"><br \/>\n<head><br \/>\n<meta charset=\"UTF-8\"><br \/>\n<meta name=\"viewport\" content=\"width=device-width,initial-scale=1.0\"><br \/>\n<title>\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09\u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\u5316\u65b9\u6848\u4e66 &#8211; \u9f99\u8109\u6696\u901a<\/title><\/p>\n<style>\n:root{--pri:#1a5276;--gold:#c8960c;--gold-light:#f0d568;--green:#27ae60;--red:#e74c3c;--bg:#f4f6f8;--card:#fff;--text:#2c3e50;--muted:#7f8c8d;--border:#e0e4e8}\n*{margin:0;padding:0;box-sizing:border-box}\nbody{font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;background:var(--bg);color:var(--text);line-height:1.8;font-size:15px}\n.container{max-width:1100px;margin:0 auto;padding:40px 20px 60px}\n.hero{background:linear-gradient(135deg,#1a5276 0%,#2471a3 40%,#2e86c1 100%);color:#fff;border-radius:14px;padding:56px 40px;text-align:center;margin-bottom:24px}\n.hero .badge{display:inline-block;background:rgba(255,255,255,.15);border:1px solid rgba(255,255,255,.3);border-radius:20px;padding:6px 20px;font-size:13px;margin-bottom:18px}\n.hero h1{font-size:34px;margin-bottom:8px;font-weight:800}\n.hero .tagline{font-size:17px;opacity:.9}\n.hero .meta-tags{display:flex;gap:10px;flex-wrap:wrap;justify-content:center;margin:18px 0}\n.hero .meta-tag{background:rgba(255,255,255,.12);border:1px solid rgba(255,255,255,.25);border-radius:20px;padding:5px 16px;font-size:12px}\n.hero .price-row{display:flex;gap:20px;flex-wrap:wrap;justify-content:center;margin-top:18px}\n.hero .price-item{background:rgba(255,255,255,.1);border-radius:12px;padding:16px 22px;min-width:150px}\n.hero .price-item .label{font-size:13px;opacity:.8;margin-bottom:4px}\n.hero .price-item .val{font-size:28px;font-weight:800;color:var(--gold-light)}\n.section{background:var(--card);border-radius:12px;padding:36px;margin-bottom:22px;box-shadow:0 1px 8px rgba(0,0,0,.04)}\n.section-header{margin-bottom:22px;padding-bottom:14px;border-bottom:2px solid var(--border)}\n.section-title{font-size:22px;font-weight:700;color:var(--pri)}\nh3{font-size:17px;color:var(--pri);border-left:3px solid var(--gold);padding-left:10px;margin:24px 0 14px}\nh4{font-size:15px;font-weight:700;margin:16px 0 10px}\n.info-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;background:#f8f9fb;border-radius:10px;padding:22px 26px;margin:14px 0}\n.info-item .ilabel{font-size:11px;color:var(--muted);margin-bottom:2px}\n.info-item .ivalue{font-size:14px;font-weight:600}\n.card-grid-3{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:14px 0}\n.icon-card{background:var(--card);border:1px solid var(--border);border-radius:10px;padding:20px 16px;text-align:center}\n.icon-card .icn{font-size:30px;margin-bottom:8px}\n.icon-card .ititle{font-size:14px;font-weight:700;margin-bottom:6px}\n.icon-card .idesc{font-size:13px;color:var(--muted);line-height:1.6}\n.table-wrap{overflow-x:auto}\ntable{width:100%;border-collapse:collapse;font-size:13px;margin:14px 0;min-width:560px}\nthead th{background:var(--pri);color:#fff;padding:10px 12px;text-align:center;font-weight:600;font-size:13px}\ntbody td{padding:9px 12px;border-bottom:1px solid var(--border);text-align:center}\ntbody tr:nth-child(even) td{background:#fafbfc}\ntfoot td{background:var(--pri)!important;color:#fff!important;font-weight:700;padding:10px 12px;text-align:center}\ntd.left{text-align:left}\n.plan-compare{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0}\n.plan-card{background:var(--card);border:2px solid var(--border);border-radius:10px;padding:22px 18px;text-align:center}\n.plan-card.rec{border-color:var(--gold);box-shadow:0 0 0 3px rgba(200,150,12,.1);position:relative}\n.plan-card.rec::before{content:\"\u2b50 \u63a8\u8350\";position:absolute;top:-11px;left:50%;transform:translateX(-50%);background:var(--gold);color:#fff;padding:3px 14px;border-radius:12px;font-size:11px;font-weight:700}\n.plan-card .pbadge{display:inline-block;padding:2px 12px;border-radius:12px;font-size:11px;font-weight:700;color:#fff;background:var(--pri);margin-bottom:8px}\n.plan-card.rec .pbadge{background:var(--gold)}\n.plan-card .pname{font-size:17px;font-weight:800;margin-bottom:4px}\n.plan-card .pprice{font-size:30px;font-weight:900;color:var(--pri);margin:6px 0}\n.plan-card.rec .pprice{color:var(--gold)}\n.plan-card .pdetail{font-size:12px;color:var(--muted);line-height:1.6}\n.product-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:14px;margin:14px 0}\n.product-card{background:var(--card);border:1px solid var(--border);border-radius:10px;padding:22px 18px;text-align:center}\n.product-card.rec-card{border-color:var(--gold);border-width:2px}\n.product-card .pbrand{font-size:13px;color:var(--muted);margin-bottom:4px}\n.product-card .pmodel{font-size:15px;font-weight:800;margin-bottom:6px}\n.product-card .pspec{font-size:12px;color:var(--muted);margin-bottom:6px;line-height:1.5}\n.product-card .pprice{font-size:20px;font-weight:800;color:var(--red);margin:6px 0}\n.product-card .ptag{display:inline-block;padding:2px 8px;border-radius:6px;font-size:10px;font-weight:700;background:#e8f8f0;color:var(--green);margin:2px}\n.callout{padding:14px 18px;margin:14px 0;font-size:13px;border-radius:0 6px 6px 0}\n.callout.note{background:#fef9e7;border-left:3px solid var(--gold);color:#6b5900}\n.callout.info{background:#eaf2f8;border-left:3px solid #4db8ff;color:var(--pri)}\n.callout.warn{background:#fdedec;border-left:3px solid var(--red);color:#922b21}\n.check-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0}\n.check-card{padding:18px;border-radius:10px}\n.check-card.inc{background:#e8f8f0;border:1px solid #a3d9b1}\n.check-card.exc{background:#fdedec;border:1px solid #f5b7b1}\n.check-card .ch{font-size:16px;font-weight:700;margin-bottom:8px}\n.check-card.inc .ch{color:var(--green)}\n.check-card.exc .ch{color:var(--red)}\n.check-card ul{font-size:12px;color:#555;padding-left:18px;line-height:1.8;margin:0}\n.kpi-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:12px;margin:14px 0}\n.kpi-card{background:#f8f9fb;border:1px solid var(--border);border-radius:8px;padding:18px}\n.kpi-card .ki{font-size:20px;margin-bottom:6px}\n.kpi-card .kt{font-size:14px;font-weight:700;margin-bottom:4px}\n.kpi-card .kd{font-size:12px;color:var(--muted);line-height:1.6}\n.lc-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0}\n.lc-card{background:var(--card);border-radius:10px;padding:18px;text-align:center}\n.lc-card.a{border:2px solid var(--border)}\n.lc-card.b{border:2px solid var(--gold)}\n.lc-card .lctitle{font-size:15px;font-weight:700;margin-bottom:10px}\n.process-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:14px 0}\n.process-step{text-align:center;padding:16px 10px;background:var(--card);border:1px solid var(--border);border-radius:8px}\n.process-step .psnum{font-size:20px;font-weight:800;color:var(--pri);margin-bottom:4px}\n.process-step .pstitle{font-size:12px;font-weight:700;margin-bottom:3px}\n.process-step .psdesc{font-size:11px;color:var(--muted);line-height:1.5}\n.process-step.plus{background:#fef9e7;border-color:var(--gold)}\n.footer-box{background:var(--pri);color:#fff;border-radius:12px;padding:32px;text-align:center;margin:22px 0}\n.footer-box h3{color:#fff;border-left-color:rgba(255,255,255,.3);display:inline-block;margin-top:0}\n.footer-box p{color:rgba(255,255,255,.9)}\n.page-footer{text-align:center;color:var(--muted);font-size:11px;padding:16px}\n.red{color:var(--red)}.gold{color:var(--gold)}\n@media(max-width:768px){.info-grid,.card-grid-3,.plan-compare,.product-grid,.kpi-grid,.lc-grid,.process-grid,.check-grid{grid-template-columns:1fr}.hero h1{font-size:22px}.hero{padding:36px 20px}.section{padding:24px}.hero .price-item{padding:12px 14px;min-width:110px}.hero .price-item .val{font-size:20px}}\n@media print{body{background:#fff}.container{max-width:100%;padding:0}.section{box-shadow:none;border:1px solid #ddd;break-inside:avoid}}\n<\/style>\n<p><\/head><br \/>\n<body><\/p>\n<div class=\"container\">\n<div class=\"hero\">\n<div class=\"badge\">\u9f99\u8109\u6696\u901a \u00b7 \u4e13\u4e1a\u6696\u901a\u65b9\u6848<\/div>\n<h1>\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09\u00b7 \u6696\u901a\u65b9\u6848\u4e66<\/h1>\n<p class=\"tagline\">3\u697c \u00b7 \u5957\u5185122\u33a1 \u6a2a\u5385\u5e73\u5c42 \u00b7 \u5df2\u6253\u62c6\u5b8c\u6bd5 | \u4e2d\u592e\u7a7a\u8c03 + \u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696<\/p>\n<div class=\"meta-tags\">\n    <span class=\"meta-tag\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217<\/span><span class=\"meta-tag\">\u4e00\u62d6\u4e94 \/ \u4e00\u62d6\u56db<\/span><span class=\"meta-tag\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/span><span class=\"meta-tag\">\u4f1f\u661fDe32\u5730\u6696<\/span><span class=\"meta-tag\">WiFi\u5206\u5ba4\u8054\u52a8<\/span>\n  <\/div>\n<div class=\"price-row\">\n<div class=\"price-item\">\n<div class=\"label\">\u2b50 \u63a8\u8350\u5957\u9910\uff08\u65b9\u6848A+\u5730\u6696\uff09<\/div>\n<div class=\"val\">\u00a550,694<\/div>\n<\/div>\n<div class=\"price-item\">\n<div class=\"label\">\u7ecf\u6d4e\u5957\u9910\uff08\u65b9\u6848B+\u5730\u6696\uff09<\/div>\n<div class=\"val\">\u00a545,683<\/div>\n<\/div><\/div>\n<\/div>\n<p><!-- ====== \u4e00\u3001\u9879\u76ee\u6982\u51b5 ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u4e00\u3001\u9879\u76ee\u6982\u51b5<\/div>\n<\/div>\n<p style=\"margin-bottom:12px\"><strong>\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09<\/strong> \u2014 3\u697c\u5e73\u5c42\uff0c\u5957\u5185122\u33a1\uff0c\u6a2a\u538546\u33a1\u3002\u5e38\u4f4f3\u4eba\uff08\u592b\u59bb+\u5973\u513f+\u8001\u4eba\uff09\u3002\u623f\u5b50<strong>\u5df2\u6253\u62c6\u5b8c\u6bd5<\/strong>\uff0c\u539f\u8ba1\u5212\u98ce\u7ba1\u673a+\u6302\u673a\uff0c\u540e\u6539\u4e3a\u5168\u5c4b\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e00\u6b65\u5230\u4f4d\u3002<\/p>\n<div class=\"info-grid\">\n<div class=\"info-item\">\n<div class=\"ilabel\">\u5ba2\u6237<\/div>\n<div class=\"ivalue\">\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u9879\u76ee\u5730\u5740<\/div>\n<div class=\"ivalue red\">\u8bf7\u8865\u5145\u5c0f\u533a\u540d\u79f0<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u623f\u5c4b<\/div>\n<div class=\"ivalue\">3\u697c \u00b7 \u5957\u5185122\u33a1<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u5ba2\u9910\u5385<\/div>\n<div class=\"ivalue\">\u6a2a\u5385 \u00b7 46\u33a1<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u4e3b\u5367<\/div>\n<div class=\"ivalue\">16\u33a1<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u5973\u513f\u623f<\/div>\n<div class=\"ivalue\">13.5\u33a1<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u8001\u4eba\u623f<\/div>\n<div class=\"ivalue\">12\u33a1<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u5e38\u4f4f\u4eba\u53e3<\/div>\n<div class=\"ivalue\">3\u4eba\uff08\u592b\u59bb+\u5973\u513f+\u8001\u4eba\uff09<\/div>\n<\/div>\n<div class=\"info-item\">\n<div class=\"ilabel\">\u88c5\u4fee\u72b6\u6001<\/div>\n<div class=\"ivalue\">\u5df2\u6253\u62c6\u5b8c\u6bd5<\/div>\n<\/div><\/div>\n<h3>\u6838\u5fc3\u9700\u6c42<\/h3>\n<p style=\"font-size:14px;color:var(--pri);margin-bottom:12px\"><strong>\u5f20\u5973\u58eb\u539f\u8bdd\uff1a<\/strong>&#8220;\u623f\u5b50\u521a\u6253\u62c6\u5b8c\uff0c\u60f3\u7a7a\u8c03\u548c\u5730\u6696\u4e00\u6b65\u5230\u4f4d\uff0c\u4e0d\u60f3\u6765\u56de\u6298\u817e\u3002\u5ba2\u5385\u662f\u6a2a\u5385\u6bd4\u8f83\u5927\uff0c\u62c5\u5fc3\u4e00\u53f0\u7a7a\u8c03\u4e0d\u591f\u3002\u8fd8\u6709\uff0c\u4e07\u4e00\u4ee5\u540e\u574f\u4e86\u8981\u62c6\u540a\u9876\u5c31\u592a\u9ebb\u70e6\u4e86\u3002&#8221;<\/p>\n<div class=\"card-grid-3\">\n<div class=\"icon-card\">\n<div class=\"icn\">\ud83c\udf2c\ufe0f<\/div>\n<div class=\"ititle\">\u6a2a\u5385\u5747\u5300\u9001\u98ce<\/div>\n<div class=\"idesc\">46\u33a1\u6a2a\u5385\uff0c\u5355\u53f0\u5185\u673a\u9001\u98ce\u8ddd\u79bb\u6709\u9650\uff0c\u4e24\u5934\u6e29\u5dee\u53ef\u8fbe2~3\u2103\u3002<\/div>\n<\/div>\n<div class=\"icon-card\">\n<div class=\"icn\">\ud83d\udd25<\/div>\n<div class=\"ititle\">\u5168\u5c4b\u5730\u6696\u4e00\u6b65\u5230\u4f4d<\/div>\n<div class=\"idesc\">\u91c7\u669687.5\u33a1\uff0c\u5347\u6e29\u5747\u5300\u3001\u4e0d\u5360\u5c42\u9ad8\u3002\u7a7a\u8c03+\u5730\u6696\u8054\u5355\u7701\u94b1\u3002<\/div>\n<\/div>\n<div class=\"icon-card\">\n<div class=\"icn\">\ud83d\udd27<\/div>\n<div class=\"ititle\">\u7ef4\u4fee\u4e0d\u62c6\u540a\u9876<\/div>\n<div class=\"idesc\">\u62c5\u5fc3\u4e2d\u592e\u7a7a\u8c03\u574f\u4e86\u8981\u62c6\u540a\u9876\u4fee\u3002<\/div>\n<\/div><\/div>\n<h4>\u4e09\u5957\u65b9\u6848\u6838\u5fc3\u5bf9\u6bd4<\/h4>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u5bf9\u6bd4\u9879<\/th>\n<th style=\"background:#27ae60;\">\u2b50 \u65b9\u6848A\uff1a\u4e00\u62d6\u4e94<\/th>\n<th style=\"background:#2471a3;\">\u65b9\u6848B\uff1a\u4e00\u62d6\u56db<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u5916\u673a<\/strong><\/td>\n<td>\u8212\u4eab140\u5355\u98ce\u6247 RAS-140HRNAQ<\/td>\n<td>\u8212\u4eab125\u5355\u98ce\u6247 RAS-125HRNAQ<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5ba2\u5385\u5185\u673a<\/strong><\/td>\n<td>71\u578b + 22\u578b\uff08\u4e24\u53f0\uff0c\u6a2a\u5385\u6c14\u6d41\u5747\u5300\uff09<\/td>\n<td>71\u578b\uff08\u4e00\u53f0\uff0c\u591f\u7528\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5185\u673a\u603b\u6570<\/strong><\/td>\n<td>5\u53f0\uff08\u5ba22+\u4e3b1+\u59731+\u80011\uff09<\/td>\n<td>4\u53f0\uff08\u5ba21+\u4e3b1+\u59731+\u80011\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u603b\u5236\u51b7\u91cf<\/strong><\/td>\n<td>17.2kW<\/td>\n<td>15.0kW<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u8fde\u63a5\u7387<\/strong><\/td>\n<td>122.9% \u2705<\/td>\n<td>120.0% \u2705<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u7a7a\u8c03\u5230\u624b\u4ef7<\/strong><\/td>\n<td class=\"gold\" style=\"font-weight:700;\">28,507\u5143<\/td>\n<td style=\"font-weight:700;\">23,496\u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5730\u6696\u5230\u624b\u4ef7<\/strong><\/td>\n<td>22,187\u5143<\/td>\n<td>22,187\u5143<\/td>\n<\/tr>\n<tr style=\"background:#fef9e7;\">\n<td class=\"left\"><strong>\u7a7a\u8c03+\u5730\u6696\u5408\u8ba1<\/strong><\/td>\n<td style=\"font-size:20px;font-weight:800;\" class=\"gold\">~50,694\u5143<\/td>\n<td style=\"font-size:18px;font-weight:800;\">~45,683\u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u63a8\u8350\u573a\u666f<\/strong><\/td>\n<td>46\u33a1\u6a2a\u5385\u8ffd\u6c42\u6c14\u6d41\u5747\u5300 \u2192 \u9009\u4e00\u62d6\u4e94<\/td>\n<td>\u9884\u7b97\u4f18\u5148\u3001\u5ba2\u5385\u4e00\u53f0\u591f\u7528 \u2192 \u9009\u4e00\u62d6\u56db<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"callout note\"><strong>\ud83d\udca1 \u4e00\u53e5\u8bdd\uff1a<\/strong>\u4e00\u62d6\u56db\u5916\u673a125\u591f\u7528\uff0c\u4e00\u62d6\u4e94\u5916\u673a140\u624d\u591f\u2014\u2014\u591a\u4e00\u53f0\u5185\u673a\uff0c\u4e3b\u673a\u5c31\u8981\u5927\u4e00\u53f7\uff0c\u5dee5,011\u5143\u5c31\u662f\u8fd9\u53f0\u5185\u673a+\u4e3b\u673a\u5347\u7ea7\u7684\u94b1\u3002<\/div>\n<\/div>\n<p><!-- ====== \u4e8c\u3001\u7a7a\u8c03\u65b9\u6848\u8be6\u7ec6\u914d\u7f6e ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u4e8c\u3001\u7a7a\u8c03\u65b9\u6848\u8be6\u7ec6\u914d\u7f6e<\/div>\n<\/div>\n<h3>\u65b9\u6848A\uff1a\u8212\u4eab140\u5355\u98ce\u6247 \u00b7 \u4e00\u62d6\u4e94 \u2b50\u63a8\u8350<\/h3>\n<p style=\"font-size:13px;color:var(--muted);margin-bottom:12px\">\u5916\u673a\uff1aRAS-140HRNAQ | \u5236\u51b714.0kW \/ \u5236\u70ed16.0kW | APF 5.80 | \u5c3a\u5bf8770\u00d7980\u00d7360mm | \u566a\u97f354dB<\/p>\n<h4>\u5185\u673a\u914d\u7f6e<\/h4>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u623f\u95f4<\/th>\n<th>\u9762\u79ef<\/th>\n<th>\u5185\u673a\u578b\u53f7<\/th>\n<th>\u5236\u51b7\u91cf<\/th>\n<th>\u5236\u70ed\u91cf<\/th>\n<th>\u566a\u97f3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u5ba2\u9910\u5385\uff08\u4e3b\uff09<\/strong><\/td>\n<td rowspan=\"2\">46\u33a1<\/td>\n<td>RPIZ-71FSNAQD\/P<\/td>\n<td>7.1kW<\/td>\n<td>8.0kW<\/td>\n<td>21dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5ba2\u9910\u5385\uff08\u8f85\uff09<\/strong><\/td>\n<td>RPIZ-22FSNAQD\/P<\/td>\n<td>2.2kW<\/td>\n<td>2.5kW<\/td>\n<td>21dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u4e3b\u5367<\/strong><\/td>\n<td>16\u33a1<\/td>\n<td>RPIZ-32FSNAQD\/P<\/td>\n<td>3.2kW<\/td>\n<td>3.6kW<\/td>\n<td>19dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5973\u513f\u623f<\/strong><\/td>\n<td>13.5\u33a1<\/td>\n<td>RPIZ-25FSNAQD\/P<\/td>\n<td>2.5kW<\/td>\n<td>2.8kW<\/td>\n<td>28dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u8001\u4eba\u623f<\/strong><\/td>\n<td>12\u33a1<\/td>\n<td>RPIZ-22FSNAQD\/P<\/td>\n<td>2.2kW<\/td>\n<td>2.5kW<\/td>\n<td>21dB<\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<tr>\n<td colspan=\"2\">5\u53f0\u5185\u673a\u5408\u8ba1<\/td>\n<td>\u2014<\/td>\n<td><strong>17.2kW<\/strong><\/td>\n<td><strong>19.4kW<\/strong><\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tfoot>\n<\/table>\n<\/div>\n<h4>\u4ef7\u683c\u660e\u7ec6<\/h4>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u8ba1\u7b97\u65b9\u5f0f<\/th>\n<th>\u91d1\u989d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\">\u8bbe\u5907\u9762\u4ef7<\/td>\n<td class=\"left\">\u5916\u673a12,875 + 71=3,513 + 22=3,013 + 32=3,100 + 25=3,050 + 22=3,013<\/td>\n<td>28,564<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">8\u6298\u76f4\u4f9b<\/td>\n<td class=\"left\">28,564 \u00d7 80%<\/td>\n<td>22,850<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5b89\u88c5\u8d39<\/td>\n<td class=\"left\">\u5916\u673a600 + \u5185\u673a5\u00d71,600<\/td>\n<td>8,600<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">WiFi\u7ebf\u63a7\u5668<\/td>\n<td class=\"left\">5\u53f0 \u00d7 200\u5143<\/td>\n<td>1,000<\/td>\n<\/tr>\n<tr style=\"background:#f0f0f0;\">\n<td class=\"left\"><strong>\u6298\u540e\u5c0f\u8ba1<\/strong><\/td>\n<td><\/td>\n<td><strong>32,450<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u56fd\u8865<\/td>\n<td class=\"left\">-1,500\u5143<\/td>\n<td class=\"red\">-1,500<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5382\u5bb6\u4f18\u60e0<\/td>\n<td class=\"left\">-500\u5143<\/td>\n<td class=\"red\">-500<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u518d\u4f18\u60e05%<\/td>\n<td class=\"left\">32,450 \u00d7 5%<\/td>\n<td class=\"red\">-1,142<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u4f1a\u5458\u4f18\u60e0<\/td>\n<td class=\"left\">-1,000\u5143<\/td>\n<td class=\"red\">-1,000<\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<tr>\n<td colspan=\"2\"><strong>\u65b9\u6848A \u7a7a\u8c03\u5230\u624b\u4ef7\uff08\u542b199\u5143\u4f1a\u5458\uff09<\/strong><\/td>\n<td style=\"font-size:18px;\"><strong>28,507\u5143<\/strong><\/td>\n<\/tr>\n<\/tfoot>\n<\/table>\n<\/div>\n<h3>\u65b9\u6848B\uff1a\u8212\u4eab125\u5355\u98ce\u6247 \u00b7 \u4e00\u62d6\u56db<\/h3>\n<p style=\"font-size:13px;color:var(--muted);margin-bottom:12px\">\u5916\u673a\uff1aRAS-125HRNAQ | \u5236\u51b712.5kW \/ \u5236\u70ed14.0kW | APF 5.90 | \u5c3a\u5bf8770\u00d7980\u00d7360mm | \u566a\u97f354dB<\/p>\n<h4>\u5185\u673a\u914d\u7f6e<\/h4>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u623f\u95f4<\/th>\n<th>\u9762\u79ef<\/th>\n<th>\u5185\u673a\u578b\u53f7<\/th>\n<th>\u5236\u51b7\u91cf<\/th>\n<th>\u5236\u70ed\u91cf<\/th>\n<th>\u566a\u97f3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u5ba2\u9910\u5385<\/strong><\/td>\n<td>46\u33a1<\/td>\n<td>RPIZ-71FSNAQD\/P<\/td>\n<td>7.1kW<\/td>\n<td>8.0kW<\/td>\n<td>21dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u4e3b\u5367<\/strong><\/td>\n<td>16\u33a1<\/td>\n<td>RPIZ-32FSNAQD\/P<\/td>\n<td>3.2kW<\/td>\n<td>3.6kW<\/td>\n<td>19dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5973\u513f\u623f<\/strong><\/td>\n<td>13.5\u33a1<\/td>\n<td>RPIZ-25FSNAQD\/P<\/td>\n<td>2.5kW<\/td>\n<td>2.8kW<\/td>\n<td>28dB<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u8001\u4eba\u623f<\/strong><\/td>\n<td>12\u33a1<\/td>\n<td>RPIZ-22FSNAQD\/P<\/td>\n<td>2.2kW<\/td>\n<td>2.5kW<\/td>\n<td>21dB<\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<tr>\n<td colspan=\"2\">4\u53f0\u5185\u673a\u5408\u8ba1<\/td>\n<td>\u2014<\/td>\n<td><strong>15.0kW<\/strong><\/td>\n<td><strong>16.9kW<\/strong><\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tfoot>\n<\/table>\n<\/div>\n<h4>\u4ef7\u683c\u660e\u7ec6<\/h4>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u8ba1\u7b97\u65b9\u5f0f<\/th>\n<th>\u91d1\u989d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\">\u8bbe\u5907\u9762\u4ef7<\/td>\n<td class=\"left\">\u5916\u673a11,663 + 71=3,513 + 32=3,100 + 25=3,050 + 22=3,013<\/td>\n<td>24,339<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">8\u6298\u76f4\u4f9b<\/td>\n<td class=\"left\">24,339 \u00d7 80%<\/td>\n<td>19,470<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5b89\u88c5\u8d39<\/td>\n<td class=\"left\">\u5916\u673a600 + \u5185\u673a4\u00d71,600<\/td>\n<td>7,000<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">WiFi\u7ebf\u63a7\u5668<\/td>\n<td class=\"left\">4\u53f0 \u00d7 200\u5143<\/td>\n<td>800<\/td>\n<\/tr>\n<tr style=\"background:#f0f0f0;\">\n<td class=\"left\"><strong>\u6298\u540e\u5c0f\u8ba1<\/strong><\/td>\n<td><\/td>\n<td><strong>27,270<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u56fd\u8865<\/td>\n<td class=\"left\">-1,500\u5143<\/td>\n<td class=\"red\">-1,500<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5382\u5bb6\u4f18\u60e0<\/td>\n<td class=\"left\">-500\u5143<\/td>\n<td class=\"red\">-500<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u518d\u4f18\u60e05%<\/td>\n<td class=\"left\">27,270 \u00d7 5%<\/td>\n<td class=\"red\">-973<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u4f1a\u5458\u4f18\u60e0<\/td>\n<td class=\"left\">-1,000\u5143<\/td>\n<td class=\"red\">-1,000<\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<tr>\n<td colspan=\"2\"><strong>\u65b9\u6848B \u7a7a\u8c03\u5230\u624b\u4ef7\uff08\u542b199\u5143\u4f1a\u5458\uff09<\/strong><\/td>\n<td style=\"font-size:18px;\"><strong>23,496\u5143<\/strong><\/td>\n<\/tr>\n<\/tfoot>\n<\/table>\n<\/div>\n<div class=\"callout note\">\ud83d\udca1 \u591a\u4e00\u53f0\u5185\u673a + \u4e3b\u673a\u5927\u4e00\u53f7 = \u8d355,011\u5143\uff0c\u6362\u676546\u33a1\u6a2a\u5385\u4e24\u5934\u9001\u98ce\uff0c\u6e29\u5dee\u5c0f\u3001\u4f53\u611f\u5747\u5300\u3002<\/div>\n<h4>\u7a7a\u8c03\u5305\u542b\u4e0e\u4e0d\u5305\u542b<\/h4>\n<div class=\"check-grid\">\n<div class=\"check-card inc\">\n<div class=\"ch\">\u2705 \u5305\u542b<\/div>\n<ul>\n<li>\u8bbe\u5907\u3001\u6807\u51c6\u94dc\u7ba1\/\u4fdd\u6e29\/\u4fe1\u53f7\u7ebf\/\u51b7\u51dd\u6c34\u7ba1\u7b49\u5168\u90e8\u8f85\u6750<\/li>\n<li>\u7ba1\u8def\u8fc7\u6881\u5f00\u5b54\/\u7a7f\u5899\u5f00\u5b54\uff08\u4e0d\u542b\u627f\u91cd\u7ed3\u6784\uff09<\/li>\n<li>\u8bbe\u5907\u8fd0\u8f93\u53ca\u4e0a\u697c\u642c\u8fd0<\/li>\n<li>\u6807\u51c6\u5185\u673a+\u5916\u673a\u5b89\u88c5<\/li>\n<li>WiFi\u7ebf\u63a7\u5668\u5b89\u88c5<\/li>\n<li>\u7cfb\u7edf\u8c03\u8bd5\u5f00\u673a<\/li>\n<\/ul><\/div>\n<div class=\"check-card exc\">\n<div class=\"ch\">\u274c \u4e0d\u5305\u542b<\/div>\n<ul>\n<li>\u5916\u5899\u7ba1\u8def\u7f8e\u5316<\/li>\n<li>\u4e3b\u673a\u7535\u6e90\u7ebf\uff08\u4ece\u914d\u7535\u7bb1\u5230\u4e3b\u673a\uff09<\/li>\n<li>\u4e3b\u673a\u4f4d\u7f6e\u57fa\u7840\u5efa\u8bbe\uff08\u56de\u586b\/\u642d\u67b6\u5b50\/\u6392\u6c34\/\u63a5\u6c34\u76d8\uff09<\/li>\n<li>\u4e0b\u51fa\u98ce\u98ce\u7ba1\uff08\u6807\u51c6\u4e3a\u4fa7\u51fa\u4e0b\u56de\uff09<\/li>\n<li>\u51fa\u98ce\u53e3\u52a0\u957f<\/li>\n<li>\u540a\u9876\u62c6\u9664\u53ca\u6062\u590d\u3001\u5899\u9762\u5f00\u69fd\u53ca\u6062\u590d<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<h3>\u8212\u4eab\u7cfb\u5217 \u00b7 \u4e09\u5927\u6838\u5fc3\u4f18\u52bf<\/h3>\n<div class=\"card-grid-3\">\n<div class=\"icon-card\">\n<div class=\"icn\">\ud83c\udf21\ufe0f<\/div>\n<div class=\"ititle\">200\u7ea7\u7535\u5b50\u81a8\u80c0\u9600 \u00b7 \u00b10.5\u2103\u7cbe\u51c6\u63a7\u6e29<\/div>\n<div class=\"idesc\">\u6bcf\u53f0\u5185\u673a200\u7ea7\u7535\u5b50\u81a8\u80c0\u9600\uff0c\u544a\u522b&#8221;\u5f00\u5173\u5f0f&#8221;\u542f\u505c\uff0c\u6e29\u5ea6\u6ce2\u52a8\u63a7\u5236\u5728\u00b10.5\u2103\u4ee5\u5185\u3002<\/div>\n<\/div>\n<div class=\"icon-card\">\n<div class=\"icn\">\ud83c\udfed<\/div>\n<div class=\"ititle\">\u6838\u5fc3\u90e8\u4ef6100%\u65e5\u7acb\u81ea\u7814<\/div>\n<div class=\"idesc\">\u538b\u7f29\u673a\u3001\u53d8\u9891\u5668\u3001\u63a7\u5236\u7cfb\u7edf\u5168\u90e8\u81ea\u4e3b\u7814\u53d1\uff0c\u975e\u62fc\u88c5\u3002\u54c1\u8d28\u53ef\u9760\u3001\u5bff\u547d\u957f\u3002<\/div>\n<\/div>\n<div class=\"icon-card\">\n<div class=\"icn\">\ud83d\udd07<\/div>\n<div class=\"ititle\">17dB\u6781\u81f4\u9759\u97f3<\/div>\n<div class=\"idesc\">\u6700\u4f4e\u8fd0\u884c\u566a\u97f3\u4ec517\u5206\u8d1d\uff0c\u6bd4\u7ffb\u4e66\u8fd8\u5b89\u9759\u3002\u4e3b\u536732\u578b\u4ec519dB\u3002<\/div>\n<\/div><\/div>\n<\/div>\n<p><!-- ====== \u4e09\u3001\u51b7\u8d1f\u8377\u6838\u7b97 ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u4e09\u3001\u51b7\u8d1f\u8377\u6838\u7b97<\/div>\n<\/div>\n<div class=\"callout info\"><strong>\u8bbe\u8ba1\u4f9d\u636e\uff1a<\/strong>GB 50736-2012 \u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303 \u00b7 \u6210\u90fd\u590f\u5b63\u8bbe\u8ba1\u6e29\u5ea631.8\u2103\/26.7\u2103(\u5e72\u7403\/\u6e7f\u7403)<\/div>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u623f\u95f4<\/th>\n<th>\u9762\u79ef<\/th>\n<th>\u51b7\u8d1f\u8377\u7cfb\u6570<\/th>\n<th>\u9700\u51b7\u91cf<\/th>\n<th>\u9009\u914d\u5185\u673a<\/th>\n<th>\u5b9e\u9645\u51b7\u91cf<\/th>\n<th>\u5339\u914d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u5ba2\u9910\u5385<\/strong><\/td>\n<td>46\u33a1<\/td>\n<td>180W\/\u33a1<\/td>\n<td>8.3kW<\/td>\n<td>71\u578b + 22\u578b<\/td>\n<td>9.3kW<\/td>\n<td class=\"green\">\u2705 112%<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u4e3b\u5367<\/strong><\/td>\n<td>16\u33a1<\/td>\n<td>180W\/\u33a1<\/td>\n<td>2.9kW<\/td>\n<td>32\u578b<\/td>\n<td>3.2kW<\/td>\n<td class=\"green\">\u2705 110%<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5973\u513f\u623f<\/strong><\/td>\n<td>13.5\u33a1<\/td>\n<td>180W\/\u33a1<\/td>\n<td>2.4kW<\/td>\n<td>25\u578b<\/td>\n<td>2.5kW<\/td>\n<td class=\"green\">\u2705 104%<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u8001\u4eba\u623f<\/strong><\/td>\n<td>12\u33a1<\/td>\n<td>180W\/\u33a1<\/td>\n<td>2.2kW<\/td>\n<td>22\u578b<\/td>\n<td>2.2kW<\/td>\n<td class=\"green\">\u2705 100%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"callout note\"><strong>\u5ba2\u9910\u538546\u33a1\u6a2a\u5385\u4e3a\u4ec0\u4e48\u752871+22\u4e24\u53f0\uff1f<\/strong>\u6a2a\u5385\u957f\u6761\u5f62\u5e03\u5c40\uff0c\u4e00\u53f071\u5185\u673a\u88c5\u5728\u4e2d\u95f4\uff0c\u8fdc\u7aef\u9001\u98ce\u8ddd\u79bb\u8d855\u7c73\u65f6\u5236\u51b7\u6548\u679c\u6253\u6298\u6263\u3002\u52a0\u4e00\u53f022\u578b\u88c5\u5728\u8fdc\u7aef\u5f62\u6210&#8221;\u5bf9\u5439&#8221;\uff0c\u4e24\u5934\u6e29\u5dee\u63a7\u5236\u57281\u2103\u4ee5\u5185\u3002\u4e00\u62d6\u4e94\u6bd4\u4e00\u62d6\u56db\u591a\u82b15,011\u5143\uff0c\u6362\u676546\u33a1\u6a2a\u5385\u5168\u7a0b\u5747\u5300\u9001\u98ce\u3002<\/div>\n<\/div>\n<p><!-- ====== \u56db\u3001\u5730\u6696\u65b9\u6848 ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u56db\u3001\u5730\u6696\u65b9\u6848\uff1a\u83f2\u65af\u66fc\u51b7\u51dd\u7089 + \u4f1f\u661f\u7cfb\u7edf<\/div>\n<\/div>\n<h3>\u7cfb\u7edf\u914d\u7f6e<\/h3>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u89c4\u683c<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u9505\u7089<\/strong><\/td>\n<td>\u83f2\u65af\u66fc\u51b7\u51dd\u7089 25kW<\/td>\n<td class=\"left\">\u51b7\u51dd\u6548\u7387106%\uff0c\u6bd4\u666e\u901a\u7089\u7701\u6c1430%<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u4e3b\u7ba1<\/strong><\/td>\n<td>\u4f1f\u661f De32<\/td>\n<td class=\"left\">\u5927\u6d41\u91cf\uff0c\u662f\u666e\u901aDe25\u76842\u500d<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u76d8\u7ba1<\/strong><\/td>\n<td>\u4f1f\u661f De16 PERT\u963b\u6c27\u7ba1<\/td>\n<td class=\"left\">\u95f4\u8ddd150mm\uff0c50\u5e74\u8bbe\u8ba1\u5bff\u547d<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5206\u96c6\u6c34\u5668<\/strong><\/td>\n<td>\u4f1f\u661f \u94dc\u9540\u954d\u5e26\u6d41\u91cf\u8ba1<\/td>\n<td class=\"left\">\u6bcf\u8def\u72ec\u7acb\u8c03\u8282<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u63a7\u5236<\/strong><\/td>\n<td>WiFi\u5206\u5ba4\u8054\u52a8<\/td>\n<td class=\"left\">\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\uff0c\u624b\u673a\u8fdc\u7a0b<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u91c7\u6696\u9762\u79ef<\/strong><\/td>\n<td>87.5\u33a1<\/td>\n<td class=\"left\">\u4e0d\u542b\u536b\u751f\u95f4\u548c\u53a8\u623f<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5b8c\u6210\u9762\u9ad8\u5ea6<\/strong><\/td>\n<td>\u6e7f\u5f0f\u5730\u6696\u4ec5 4.5cm<\/td>\n<td class=\"left\">2.8m\u5c42\u9ad8\u94fa\u5b8c\u8fd8\u67092.75m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>\u4ef7\u683c\u660e\u7ec6<\/h3>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u8ba1\u7b97\u8fc7\u7a0b<\/th>\n<th>\u91d1\u989d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\">\u9505\u7089\u539f\u4ef7<\/td>\n<td class=\"left\">\u83f2\u65af\u66fc25kW\u51b7\u51dd\u7089<\/td>\n<td>13,579<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5355\u4e709\u6298<\/td>\n<td class=\"left\">13,579 \u00d7 90%<\/td>\n<td>12,221<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u7a7a\u8c03\u8054\u5355\u518d9\u6298<\/td>\n<td class=\"left\">12,221 \u00d7 90%<\/td>\n<td>10,999<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u56fd\u8865<\/td>\n<td class=\"left\">-1,500\u5143<\/td>\n<td class=\"red\">-1,500<\/td>\n<\/tr>\n<tr style=\"background:#fef9e7;\">\n<td class=\"left\"><strong>\u9505\u7089\u5230\u624b\u4ef7<\/strong><\/td>\n<td><\/td>\n<td><strong>9,499\u5143<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5730\u6696\u94fa\u8bbe<\/strong><\/td>\n<td class=\"left\">87.5\u33a1 \u00d7 145\u5143\/\u33a1<br \/><span style=\"font-size:11px;color:var(--muted);\">\u542bDe32\u4e3b\u7ba1+De16\u76d8\u7ba1+\u5206\u96c6\u6c34\u5668+\u56de\u586b+WiFi\u7ebf\u63a7<\/span><\/td>\n<td><strong>12,688\u5143<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<tr>\n<td colspan=\"2\"><strong>\ud83d\udd25 \u5730\u6696\u5408\u8ba1<\/strong><\/td>\n<td style=\"font-size:18px;\"><strong>22,187\u5143<\/strong><\/td>\n<\/tr>\n<\/tfoot>\n<\/table>\n<\/div>\n<div class=\"callout note\"><strong>\u2705 \u8054\u5355\u4e13\u5c5e\u4f18\u60e0\uff1a<\/strong>\u7a7a\u8c03+\u5730\u6696\u4e00\u8d77\u5b9a\uff0c\u9505\u7089\u4eab\u53cc\u91cd9\u6298\uff0c\u4ec5\u9505\u7089\u4e00\u9879\u5c31\u77012,222\u5143\u3002<\/div>\n<h3>\u8bbe\u8ba1\u903b\u8f91 \u2014\u2014 \u4e3a\u4ec0\u4e48\u8fd9\u4e48\u914d<\/h3>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u8981\u70b9<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u51b7\u51dd\u7089\u914dDe32\u4e3b\u7ba1<\/strong><\/td>\n<td class=\"left\">\u5927\u6d41\u91cf\u662f\u8282\u80fd\u7684\u5173\u952e\u2014\u2014\u597d\u8f66\u8981\u914d\u597d\u8def\u3002De32\u6d41\u91cf\u6bd4\u666e\u901aDe25\u7ffb\u500d\uff0c\u672b\u6bb5\u4e0d\u8870\u51cf\uff0c\u51b7\u51dd\u7089\u7684\u8282\u80fd\u4f18\u52bf\u624d\u80fd\u9001\u5230\u6bcf\u4e2a\u623f\u95f4<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5206\u5ba4\u8054\u52a8\u63a7\u6e29<\/strong><\/td>\n<td class=\"left\">\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acbWiFi\u6e29\u63a7\uff0c\u54ea\u4e2a\u623f\u95f4\u5230\u4e86\u6e29\u5ea6\u5c31\u81ea\u52a8\u5173\u3001\u9505\u7089\u81ea\u52a8\u964d\u706b\u3002\u7528\u54ea\u4e2a\u5f00\u54ea\u4e2a\uff0c<strong>\u80fd\u8017\u964d30%<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u5730\u66964.5cm<\/strong><\/td>\n<td class=\"left\">\u4ece\u539f\u59cb\u5730\u9762\u5230\u74f7\u7816\u5b8c\u6210\u9762\u53ea\u97004.5cm\uff0c2.8m\u5c42\u9ad8\u94fa\u5b8c\u8fd8\u67092.75m\uff0c\u5b8c\u5168\u4e0d\u538b\u6291<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4>\u5730\u6696\u5305\u542b\u4e0e\u4e0d\u5305\u542b<\/h4>\n<div class=\"check-grid\">\n<div class=\"check-card inc\">\n<div class=\"ch\">\u2705 \u5305\u542b<\/div>\n<ul>\n<li>\u9505\u7089\u8bbe\u5907\u53ca\u5b89\u88c5<\/li>\n<li>\u4f1f\u661f\u4e3b\u7ba1\/\u76d8\u7ba1\/\u5206\u96c6\u6c34\u5668\/\u53cd\u5c04\u819c<\/li>\n<li>\u5730\u6696\u56de\u586b<\/li>\n<li>\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acbWiFi\u6e29\u63a7\u5668<\/li>\n<li>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/li>\n<li>\u7cfb\u7edf\u8c03\u8bd5\u5f00\u673a<\/li>\n<\/ul><\/div>\n<div class=\"check-card exc\">\n<div class=\"ch\">\u274c \u4e0d\u5305\u542b<\/div>\n<ul>\n<li>\u539f\u59cb\u5730\u9762\u627e\u5e73<\/li>\n<li>\u5783\u573e\u6e05\u8fd0<\/li>\n<li>\u6c34\u7535\u6539\u9020<\/li>\n<li>\u9505\u7089\u70df\u7ba1\u5f00\u5b54<\/li>\n<li>\u8d85\u957f\u70df\u7ba1\u53ca\u5f2f\u5934\uff08\u6807\u914d\u4e00\u4e2a90\u00b0\u5f2f\u5934\u548c90cm\u70df\u7ba1\uff09<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/div>\n<p><!-- ====== \u4e94\u3001\u5957\u9910\u603b\u4ef7 ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u4e94\u3001\u7a7a\u8c03+\u5730\u6696\u5957\u9910\u603b\u4ef7<\/div>\n<\/div>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>\u5957\u9910\u7ec4\u5408<\/th>\n<th>\u7a7a\u8c03\u5230\u624b\u4ef7<\/th>\n<th>\u5730\u6696\u5230\u624b\u4ef7<\/th>\n<th>\u5408\u8ba1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background:#fef9e7;\">\n<td class=\"left\"><strong>\u2b50 \u63a8\u8350\u5957\u9910\uff08\u65b9\u6848A+\u5730\u6696\uff09<\/strong><\/td>\n<td>28,507\u5143<\/td>\n<td>22,187\u5143<\/td>\n<td style=\"font-size:22px;font-weight:800;\" class=\"gold\"><strong>50,694\u5143<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u7ecf\u6d4e\u5957\u9910\uff08\u65b9\u6848B+\u5730\u6696\uff09<\/strong><\/td>\n<td>23,496\u5143<\/td>\n<td>22,187\u5143<\/td>\n<td style=\"font-size:22px;font-weight:800;\" class=\"gold\"><strong>45,683\u5143<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<tr>\n<td colspan=\"2\"><strong>\u4e24\u5957\u9910\u5dee\u4ef7<\/strong><\/td>\n<td colspan=\"2\"><strong>5,011\u5143 = \u591a\u4e00\u53f0\u5185\u673a + \u4e3b\u673a\u5347\u4e00\u7ea7<\/strong><\/td>\n<\/tr>\n<\/tfoot>\n<\/table>\n<\/div>\n<h4>\u957f\u8fdc\u6765\u770b\uff1a15\u5e74\u7efc\u5408\u6210\u672c\u5bf9\u6bd4<\/h4>\n<div class=\"lc-grid\">\n<div class=\"lc-card a\">\n<div class=\"lctitle\">\u666e\u901a\u65b9\u6848\uff08\u6302\u673a+\u67dc\u673a+\u666e\u901a\u7089\uff09<\/div>\n<div class=\"table-wrap\">\n<table style=\"margin:8px 0\">\n<tbody>\n<tr>\n<td class=\"left\">\u521d\u6295\u8d44<\/td>\n<td>\u7ea6 30,000-38,000 \u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5e74\u8fd0\u884c\u8d39<\/td>\n<td>\u7ea6 3,800-5,500 \u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">15\u5e74\u8fd0\u884c\u8d39<\/td>\n<td>\u7ea6 57,000-82,500 \u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>15\u5e74\u603b\u6295\u5165<\/strong><\/td>\n<td class=\"red\" style=\"font-weight:700\">\u7ea6 87,000-120,500 \u5143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n<div class=\"lc-card b\">\n<div class=\"lctitle\">\u2b50 \u9f99\u8109\u65b9\u6848\uff08\u65e5\u7acb+\u83f2\u65af\u66fc+\u5730\u6696\uff09<\/div>\n<div class=\"table-wrap\">\n<table style=\"margin:8px 0\">\n<tbody>\n<tr>\n<td class=\"left\">\u521d\u6295\u8d44<\/td>\n<td>45,683 ~ 50,694 \u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">\u5e74\u8fd0\u884c\u8d39<\/td>\n<td>\u7ea6 2,500-3,500 \u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\">15\u5e74\u8fd0\u884c\u8d39<\/td>\n<td>\u7ea6 37,500-52,500 \u5143<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>15\u5e74\u603b\u6295\u5165<\/strong><\/td>\n<td class=\"red\" style=\"font-weight:700\">\u7ea6 83,000-103,000 \u5143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n<\/p><\/div>\n<div class=\"callout info\"><strong>\u7ed3\u8bba\uff1a<\/strong>\u867d\u7136\u521d\u6295\u8d44\u66f4\u9ad8\uff0c\u4f46\u6bcf\u5e74\u53ef\u8282\u7701\u7ea61,300-2,000\u5143\u8fd0\u884c\u8d39\u300215\u5e74\u603b\u6295\u5165\u57fa\u672c\u6301\u5e73\u751a\u81f3\u66f4\u4f4e\uff0c\u4e14\u83b7\u5f97\u66f4\u8212\u9002\u3001\u66f4\u7f8e\u89c2\u3001\u66f4\u5b89\u9759\u7684\u751f\u6d3b\u4f53\u9a8c\u3002<\/div>\n<\/div>\n<p><!-- ====== \u516d\u3001\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1 ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u516d\u3001\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c<\/div>\n<\/div>\n<h3>\u7cbe\u5de5\u516d\u6b65\u6cd5+2 \u00b7 \u65bd\u5de5\u5f71\u50cf\u6863\u6848<\/h3>\n<p style=\"font-size:13px;color:var(--muted);margin-bottom:14px\">\u7a7a\u8c03+\u5730\u6696\u53cc\u7cfb\u7edf\u534f\u540c\u65bd\u5de5\uff0c\u6bcf\u9053\u5de5\u5e8f\u62cd\u7167\u5b58\u6863\uff0c\u4ea4\u4ed8\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b<\/p>\n<div class=\"process-grid\">\n<div class=\"process-step\">\n<div class=\"psnum\">01<\/div>\n<div class=\"pstitle\">\u73b0\u573a\u52d8\u6d4b<\/div>\n<div class=\"psdesc\">\u9010\u95f4\u6d4b\u91cf\u9762\u79ef\u3001\u5c42\u9ad8\u3001\u671d\u5411<\/div>\n<\/div>\n<div class=\"process-step\">\n<div class=\"psnum\">02<\/div>\n<div class=\"pstitle\">\u7cfb\u7edf\u8bbe\u8ba1<\/div>\n<div class=\"psdesc\">\u7ed8\u5236\u94dc\u7ba1\u8d70\u5411+\u5730\u6696\u5e03\u7f6e\u56fe<\/div>\n<\/div>\n<div class=\"process-step\">\n<div class=\"psnum\">03<\/div>\n<div class=\"pstitle\">\u6750\u6599\u8fdb\u573a<\/div>\n<div class=\"psdesc\">\u4e0e\u5ba2\u6237\u5171\u540c\u9a8c\u6536\u54c1\u724c\u578b\u53f7<\/div>\n<\/div>\n<div class=\"process-step\">\n<div class=\"psnum\">04<\/div>\n<div class=\"pstitle\">\u7cfb\u7edf\u5b89\u88c5<\/div>\n<div class=\"psdesc\">\u7a7a\u8c03\u94dc\u7ba1\u6c2e\u6c14\u710a+\u5730\u6696\u76d8\u7ba1<\/div>\n<\/div>\n<div class=\"process-step\">\n<div class=\"psnum\">05<\/div>\n<div class=\"pstitle\">\u7cfb\u7edf\u8c03\u8bd5<\/div>\n<div class=\"psdesc\">\u9010\u53f0\u8bd5\u8fd0\u884c+\u5206\u5ba4\u6e29\u63a7\u9a8c\u8bc1<\/div>\n<\/div>\n<div class=\"process-step\">\n<div class=\"psnum\">06<\/div>\n<div class=\"pstitle\">\u7ae3\u5de5\u9a8c\u6536<\/div>\n<div class=\"psdesc\">\u9690\u853d\u5de5\u7a0b\u5f71\u50cf\u5f52\u6863\uff0c\u4ea4\u4ed8\u6863\u6848\u4e66<\/div>\n<\/div>\n<div class=\"process-step plus\">\n<div class=\"psnum\">+1<\/div>\n<div class=\"pstitle\">\u4ea4\u4ed8\u6559\u5b66<\/div>\n<div class=\"psdesc\">\u4e00\u5bf9\u4e00\u6559\u4f1a\u4f7f\u7528\u6e29\u63a7\u5668\u3001APP<\/div>\n<\/div>\n<div class=\"process-step plus\">\n<div class=\"psnum\">+2<\/div>\n<div class=\"pstitle\">10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/div>\n<div class=\"psdesc\">\u5e74\u5ea6\u56de\u8bbf+\u6570\u636e\u5f52\u6863\u6301\u7eed\u4f18\u5316<\/div>\n<\/div><\/div>\n<h3>\u7ef4\u4fee\u4fdd\u969c \u2014\u2014 \u56de\u7b54\u60a8\u6700\u62c5\u5fc3\u7684\u4e8b<\/h3>\n<div class=\"callout warn\"><strong>\ud83d\udd27 \u7ef4\u4fee\u4e0d\u62c6\u540a\u9876 \u2014\u2014 \u68c0\u4fee\u53e3\u5c31\u662f\u56de\u98ce\u53e3\u3002<\/strong>\u65e5\u7acb\u5185\u673a\u56de\u98ce\u53e3\u9762\u677f\u6253\u5f00\u540e\uff0c\u7535\u63a7\u76d2\u3001\u7535\u673a\u3001\u6392\u6c34\u7ba1\u5168\u90fd\u80fd\u6478\u5230\u3002\u4e09\u6b65\uff1a\u6253\u5f00\u9762\u677f \u2192 \u6362\u96f6\u4ef6(10\u5206\u949f) \u2192 \u88c5\u56de\u9762\u677f\uff0c\u5168\u7a0b\u4e0d\u78b0\u540a\u9876\u3002<\/div>\n<div class=\"callout warn\"><strong>\ud83d\udcca \u538b\u529b\u8868\u5168\u7a0b\u76d1\u6d4b \u2014\u2014 \u88c5\u4fee\u671f\u95f4\u4e0d\u7ffb\u8f66\u3002<\/strong>\u7ba1\u9053\u88c54.0MPa\u6c2e\u6c14\u4fdd\u538b\u8868\uff0c\u88c5\u4fee\u671f\u95f4\u4e00\u76f4\u6302\u7740\u3002\u4efb\u4f55\u65bd\u5de5\u635f\u4f24\u7ba1\u9053 \u2192 \u538b\u529b\u77ac\u95f4\u6389\u96f6 \u2192 \u8868\u4e0a\u76f4\u63a5\u62a5\u8b66\u3002<\/div>\n<div class=\"callout warn\"><strong>\ud83c\udfc6 12\u5e74\u524d\u7684\u65e5\u7acb\uff0c\u4e8c\u6b21\u88c5\u4fee\u7ee7\u7eed\u7528\u3002<\/strong>\u9f99\u8109\u5ba2\u62372014\u5e74\u88c5\u65e5\u7acb\uff0c2026\u5e74\u7ffb\u65b0\u5168\u5c4b\uff0c\u7a7a\u8c03\u6ca1\u6362\u6ca1\u62c6\u2014\u2014\u505a\u4e86\u6df1\u5ea6\u4fdd\u517b\u548c\u65b0\u51fa\u98ce\u53e3\uff0c\u8ddf\u65b0\u7684\u4e00\u6837\u3002\u65e5\u7acb\u8bbe\u8ba1\u5bff\u547d15-20\u5e74\u3002<\/div>\n<h3>\u552e\u540e\u4fdd\u969c<\/h3>\n<div class=\"kpi-grid\">\n<div class=\"kpi-card\">\n<div class=\"ki\">\ud83d\udee1\ufe0f<\/div>\n<div class=\"kt\">5\u5e74\u6574\u673a\u8d28\u4fdd<\/div>\n<div class=\"kd\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6574\u673a5\u5e74\u8d28\u4fdd\uff0c\u8fdc\u8d85\u56fd\u68073\u5e74\u3002\u8d28\u4fdd\u671f\u5185\u514d\u8d39\u7ef4\u4fee\u3001\u514d\u8d39\u66f4\u6362\u3002<\/div>\n<\/div>\n<div class=\"kpi-card\">\n<div class=\"ki\">\ud83d\udcca<\/div>\n<div class=\"kt\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/div>\n<div class=\"kd\">\u6bcf\u5e74\u4f7f\u7528\u5b63\u540e\u56de\u8bbf\uff0c\u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807\u3002\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae\u4e3b\u52a8\u63a8\u9001\uff0c\u5f02\u5e38\u80fd\u8017\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u3002<\/div>\n<\/div><\/div>\n<\/div>\n<p><!-- ====== \u4e03\u3001\u771f\u5b9e\u6848\u4f8b ====== --><\/p>\n<div class=\"section\">\n<div class=\"section-header\">\n<div class=\"section-title\">\u4e03\u3001\u771f\u5b9e\u6848\u4f8b\u53c2\u8003<\/div>\n<\/div>\n<h4>\u2605 \u4e1c\u5b89\u9996\u5e9c \u00b7 \u5f90\u5148\u751f\uff0894\u33a1\u5e73\u5c42\uff0c\u8212\u4eab180\u4e00\u62d6\u516d+\u65b0\u98ce\uff09<\/h4>\n<div class=\"table-wrap\">\n<table>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u6237\u578b<\/strong><\/td>\n<td>\u5e73\u5c4294\u33a1\uff0c\u53cc50\u5e76\u8054\u5ba2\u9910\u538542\u33a1<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u65b9\u6848<\/strong><\/td>\n<td>\u65e5\u7acb\u8212\u4eab180\u4e00\u62d6\u516d + \u65e5\u7acb\u5929\u51c0\u65b0\u98ce<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u53c2\u8003\u4ef7\u503c<\/strong><\/td>\n<td>\u540c\u4e3a\u5e73\u5c42\u6a2a\u5385\uff0c\u53cc\u5185\u673a\u5e76\u8054\u8bbe\u8ba1\u601d\u8def\u53ef\u53c2\u8003<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4>\u2605 \u9f99\u6e56\u4e09\u5343\u4e91\u9526 \u00b7 \u7f57\u8001\u5e08\uff08110\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u540c\u9762\u79ef\u53c2\u8003\uff09<\/h4>\n<div class=\"table-wrap\">\n<table>\n<tbody>\n<tr>\n<td class=\"left\"><strong>\u65b9\u6848<\/strong><\/td>\n<td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\u53cc\u65b9\u6848\u5bf9\u6bd4<\/td>\n<\/tr>\n<tr>\n<td class=\"left\"><strong>\u53c2\u8003\u4ef7\u503c<\/strong><\/td>\n<td>110\u33a1\u4e0e\u5f20\u5973\u58eb122\u33a1\u9762\u79ef\u63a5\u8fd1\uff0c\u65b9\u6848\u9009\u62e9\u601d\u8def\u76f8\u4f3c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"footer-box\">\n<h3>\ud83d\udcde \u8054\u7cfb\u60a8\u7684\u4e13\u5c5e\u987e\u95ee<\/h3>\n<p style=\"font-size:22px;margin:8px 0;\"><strong>\u90ed\u52c7\u79c0 18100839248<\/strong><\/p>\n<p style=\"margin:4px 0;\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u514d\u8d39\u65b9\u6848\u8bbe\u8ba1 \u00b7 \u514d\u8d39\u62a5\u4ef7<\/p>\n<p style=\"font-size:13px;margin:8px 0;\">\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<br \/>\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135<\/p>\n<p style=\"font-size:12px;opacity:.7;margin-top:8px;\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb2025\u94bb\u77f3\u5b89\u88c5\u5546 \u00b7 \u670d\u52a1\u6210\u90fd22\u5e74<\/p>\n<\/div>\n<div class=\"page-footer\">\u6570\u636e\u6765\u6e90\uff1a\u65e5\u7acb\/\u83f2\u65af\u66fc\/\u4f1f\u661f\u5b98\u65b9\u8d44\u6599\u53ca\u9f99\u8109\u6696\u901a\u4ef7\u683c\u8868 | \u5236\u4f5c\u65e5\u671f\uff1a2026\u5e747\u67085\u65e5 | \u65b9\u6848\u987e\u95ee\uff1a\u90ed\u52c7\u79c0<\/div>\n<\/div>\n<p><\/body><\/html><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09\u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\u5316\u65b9 [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-5462","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=5462\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09\u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\u5316\u65b9 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=5462\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-05T06:24:04+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5462\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5462\",\"name\":\"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-07-04T11:32:37+00:00\",\"dateModified\":\"2026-07-05T06:24:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5462#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5462\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5462#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=5462","og_locale":"zh_CN","og_type":"article","og_title":"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u5f20\u5973\u58eb\uff08\u73b2\u5170\uff09\u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\u5316\u65b9 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=5462","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-05T06:24:04+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=5462","url":"https:\/\/longmai-nt.com\/?page_id=5462","name":"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-07-04T11:32:37+00:00","dateModified":"2026-07-05T06:24:04+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=5462#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=5462"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=5462#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u9009\u8d2d\u65b9\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5462","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5462"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5462\/revisions"}],"predecessor-version":[{"id":5492,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5462\/revisions\/5492"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}