{"id":5476,"date":"2026-07-05T12:31:06","date_gmt":"2026-07-05T04:31:06","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=5476"},"modified":"2026-07-05T12:31:06","modified_gmt":"2026-07-05T04:31:06","slug":"%e6%9d%8e%e5%85%88%e7%94%9f-%c2%b7-%e6%96%b0%e9%a3%8e%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e5%af%b9%e6%af%94%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=5476","title":{"rendered":"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66"},"content":{"rendered":"\n\n<style>\n\/* ============ RESET & BASE ============ *\/\n*,*::before,*::after{margin:0;padding:0;box-sizing:border-box}\nhtml{scroll-behavior:smooth;font-size:15px}\nbody{font-family:'Segoe UI','PingFang SC','Microsoft YaHei',sans-serif;background:#faf8f5;color:#2c3e50;line-height:1.7;overflow-x:hidden}\n\n\/* ============ CSS VARIABLES ============ *\/\n:root{\n  --orange:#E8652D; --orange-light:#FDF0E8; --orange-dark:#C4511A;\n  --blue:#1a5276; --blue-light:#eaf2f8; --blue-dark:#0d3b5c;\n  --green:#27ae60; --green-light:#e8f8f0; --gold:#f39c12; --gold-light:#fef9e7;\n  --bg:#faf8f5; --card:#fff; --text:#2c3e50; --text2:#5a6c7d; --text3:#95a5a6;\n  --border:#e8ecf0; --border2:#d5dce3;\n  --sh1:0 1px 3px rgba(0,0,0,.06); --sh2:0 4px 12px rgba(0,0,0,.08); --sh3:0 8px 30px rgba(0,0,0,.1);\n  --r:12px; --rr:16px; --maxw:1400px;\n}\n\n\/* ============ WRAPPER ============ *\/\n.wrap{max-width:var(--maxw);margin:0 auto;padding:0 24px}\n\n\/* ============ HEADER ============ *\/\n.topbar{\n  background:#fff;border-bottom:1px solid var(--border);\n  display:flex;align-items:center;gap:12px;padding:12px 0;\n}\n.topbar-logo{height:36px}\n.topbar-title{font-size:1.05rem;font-weight:700;color:var(--blue)}\n.topbar-badge{font-size:.72rem;background:var(--orange-light);color:var(--orange-dark);padding:4px 12px;border-radius:99px;font-weight:600}\n.topbar-contact{margin-left:auto;font-size:.82rem;color:var(--text2)}\n.topbar-contact a{color:var(--orange);text-decoration:none;font-weight:600}\n\n\/* ============ GEO NAV TABS ============ *\/\n.geo-nav{\n  position:sticky;top:0;z-index:100;background:#fff;\n  border-bottom:1px solid var(--border);\n}\n.geo-nav-inner{\n  display:flex;gap:2px 0;flex-wrap:wrap;justify-content:center;\n  padding:4px 16px 0;max-width:var(--maxw);margin:0 auto;\n}\n.geo-nav-inner::after{content:'';flex:1 1 300px;}\n@media(max-width:900px){.geo-nav-inner{padding:4px 12px 0;justify-content:flex-start;max-width:none;overflow-x:auto;-webkit-overflow-scrolling:touch;flex-wrap:nowrap;}}\n.geo-nav a{\n  display:flex;align-items:center;gap:6px;padding:10px 16px;font-size:.8rem;font-weight:600;\n  color:var(--text2);text-decoration:none;white-space:nowrap;border-bottom:3px solid transparent;\n  transition:all .2s;flex-shrink:0;\n}\n.geo-nav a:hover{color:var(--orange);background:var(--orange-light)}\n.geo-nav a.active{color:var(--orange-dark);border-bottom-color:var(--orange)}\n.geo-nav a .geo-num{font-size:.68rem;width:20px;height:20px;display:inline-flex;align-items:center;justify-content:center;border-radius:50%;background:var(--border);color:var(--text3);font-weight:700}\n.geo-nav a.active .geo-num{background:var(--orange);color:#fff}\n\n\/* ============ HERO ============ *\/\n.hero{\n  background:linear-gradient(135deg,#1a2a3a 0%,#1a5276 30%,#2471a3 60%,#1a5276 100%);\n  padding:52px 0 44px;position:relative;overflow:hidden;margin-top:16px;border-radius:var(--rr);\n}\n.hero::before{content:'';position:absolute;top:-60px;right:-60px;width:260px;height:260px;border-radius:50%;border:2px solid rgba(255,255,255,.06)}\n.hero::after{content:'';position:absolute;bottom:-80px;left:15%;width:360px;height:360px;border-radius:50%;border:2px solid rgba(255,255,255,.04)}\n.hero-inner{max-width:var(--maxw);margin:0 auto;padding:0 40px;position:relative;z-index:1}\n.hero *{color:#fff !important}\n.hero .hero-chip{display:inline-block;background:rgba(255,255,255,.1);backdrop-filter:blur(10px);padding:5px 14px;border-radius:99px;font-size:.76rem;margin-bottom:14px;border:1px solid rgba(255,255,255,.1);color:rgba(255,255,255,.9) !important}\n.hero h1{font-size:2rem;font-weight:800;margin-bottom:6px;line-height:1.3;color:#fff !important}\n.hero .hero-sub{font-size:1rem;color:rgba(255,255,255,.78) !important;margin-bottom:18px}\n.hero .hero-meta{display:flex;flex-wrap:wrap;gap:12px 28px;font-size:.82rem;color:rgba(255,255,255,.7) !important}\n.hero .hero-meta>*{color:rgba(255,255,255,.7) !important}\n\n\/* ============ SUMMARY CARDS ============ *\/\n.summary{display:grid;grid-template-columns:repeat(auto-fit,minmax(140px,1fr));gap:14px;margin:24px 0}\n.summary-card{background:#fff;border-radius:var(--r);padding:18px 14px;text-align:center;border:1px solid var(--border);transition:all .2s}\n.summary-card:hover{box-shadow:var(--sh2);transform:translateY(-2px)}\n.summary-card .s-icon{font-size:1.6rem;margin-bottom:6px}\n.summary-card .s-val{font-size:1.3rem;font-weight:800;color:var(--blue)}\n.summary-card .s-label{font-size:.74rem;color:var(--text3);margin-top:2px}\n\n\/* ============ SECTIONS ============ *\/\n.sec{margin-top:36px;scroll-margin-top:100px}\n.sec-label{display:inline-flex;align-items:center;gap:6px;font-size:.72rem;font-weight:700;color:var(--orange);text-transform:uppercase;letter-spacing:.05em;margin-bottom:4px}\n.sec-label .pill{background:var(--orange);color:#fff;padding:1px 7px;border-radius:3px;font-size:.62rem;letter-spacing:0}\n.sec-title{font-size:1.45rem;font-weight:700;margin-bottom:18px;color:var(--text)}\n\n\/* ============ CARD ============ *\/\n.card{background:#fff;border-radius:var(--rr);padding:24px 28px;box-shadow:var(--sh1);border:1px solid var(--border);margin-bottom:16px;transition:all .25s}\n.card:hover{box-shadow:var(--sh2)}\n.card.edge-o{border-left:4px solid var(--orange)}\n.card.edge-b{border-left:4px solid var(--blue)}\n.card.edge-g{border-left:4px solid var(--green)}\n.card-head{display:flex;align-items:center;gap:10px;margin-bottom:16px}\n.card-icon{width:40px;height:40px;border-radius:8px;display:flex;align-items:center;justify-content:center;font-size:1.2rem;flex-shrink:0}\n.card-icon.co{background:var(--orange-light);color:var(--orange)}\n.card-icon.cb{background:var(--blue-light);color:var(--blue)}\n.card-icon.cg{background:var(--green-light);color:var(--green)}\n.card-title{font-size:1.05rem;font-weight:700}\n.card-sub{font-size:.78rem;color:var(--text2)}\n\n\/* ============ TABLES ============ *\/\n.tbl{width:100%;border-collapse:collapse;font-size:.83rem}\n.tbl th{background:var(--bg);padding:9px 12px;text-align:left;font-weight:600;border-bottom:2px solid var(--border2);white-space:nowrap}\n.tbl td{padding:9px 12px;border-bottom:1px solid var(--border);color:var(--text2)}\n.tbl tr:hover td{background:var(--orange-light)}\n.tbl .hi{font-weight:700;color:var(--orange)}\n.tbl .pr{font-weight:700;color:var(--blue);font-family:'SF Mono','Cascadia Code','Consolas',monospace}\n\n\/* ============ COMPARISON TABS ============ *\/\n.comp-tabs{display:flex;gap:10px;margin-bottom:20px;flex-wrap:wrap}\n.comp-tab{cursor:pointer;font-family:inherit;font-size:inherit;flex:1;min-width:190px;padding:14px 18px;border:2px solid var(--border);border-radius:var(--r);background:#fff;cursor:pointer;text-align:left;transition:all .25s;position:relative}\n.comp-tab:hover{border-color:var(--orange)}\n.comp-tab.active{border-color:var(--orange);background:var(--orange-light);box-shadow:var(--sh2)}\n.comp-tab .t-tag{display:inline-block;padding:2px 8px;border-radius:99px;font-size:.68rem;font-weight:700;margin-bottom:6px}\n.comp-tab .t-tag.t1{background:#e8f4fd;color:#2471a3}\n.comp-tab .t-tag.t2{background:var(--green-light);color:var(--green)}\n.comp-tab .t-name{font-size:.9rem;font-weight:700;display:block;margin-bottom:2px}\n.comp-tab .t-price{font-size:1.2rem;font-weight:800;color:var(--orange)}\n.comp-tab .t-recommend{position:absolute;top:-7px;right:10px;background:var(--green);color:#fff;font-size:.62rem;padding:2px 9px;border-radius:99px;font-weight:700}\n\n\/* ============ TWO COLUMN CARDS ============ *\/\n.duo{display:grid;grid-template-columns:repeat(2,1fr);gap:16px;margin:18px 0}\n.plan-card{background:#fff;border-radius:var(--rr);padding:22px 18px;border:2px solid var(--border);text-align:center;transition:all .25s;position:relative;overflow:hidden}\n.plan-card:hover{transform:translateY(-3px);box-shadow:var(--sh3)}\n.plan-card.best{border-color:var(--green)}\n.plan-card.best::before{content:'\ud83d\udc4d \u4f18\u9009\u63a8\u8350';position:absolute;top:12px;right:-28px;background:var(--green);color:#fff;font-size:.62rem;padding:2px 36px;transform:rotate(45deg);font-weight:600}\n.plan-card .p-icon{width:50px;height:50px;border-radius:50%;display:flex;align-items:center;justify-content:center;margin:0 auto 10px;font-size:1.3rem}\n.plan-card .p-name{font-size:.95rem;font-weight:700;margin-bottom:6px}\n.plan-card .p-price{font-size:1.6rem;font-weight:800;color:var(--orange);margin-bottom:10px}\n.plan-card .p-price small{font-size:.75rem;color:var(--text3);font-weight:400}\n.plan-card ul{list-style:none;text-align:left;font-size:.78rem;color:var(--text2)}\n.plan-card ul li{padding:5px 0;border-bottom:1px solid var(--border);display:flex;align-items:center;gap:6px}\n.plan-card ul li:last-child{border-bottom:none}\n.plan-card ul li::before{content:'\u25b8';color:var(--orange);font-size:.65rem}\n\n\/* ============ MATRIX ============ *\/\n.matrix{display:grid;grid-template-columns:1.5fr 1fr 1fr;gap:1px;background:var(--border);border-radius:var(--r);overflow:hidden;margin:18px 0}\n.mx{background:#fff;padding:10px 14px;font-size:.8rem;display:flex;align-items:center}\n.mx.hd{background:var(--bg);font-weight:700;color:var(--text)}\n.mx.lb{font-weight:600;color:var(--text)}\n.mx.best{color:var(--green);font-weight:700}\n\n\/* ============ STAR RATING ============ *\/\n.stars{display:flex;gap:1px;font-size:.85rem}\n.stars .st{color:#ddd}\n.stars .st.on{color:var(--gold)}\n\n\/* ============ STEPS ============ *\/\n.steps{position:relative;padding-left:28px}\n.steps::before{content:'';position:absolute;left:13px;top:0;bottom:0;width:2px;background:var(--border2)}\n.step{position:relative;margin-bottom:20px}\n.step:last-child{margin-bottom:0}\n.step .dot{position:absolute;left:-19px;top:3px;width:12px;height:12px;border-radius:50%;border:3px solid var(--orange);background:#fff;z-index:1}\n.step.done .dot{background:var(--orange)}\n.step .st{font-weight:700;font-size:.9rem;margin-bottom:3px}\n.step .sd{font-size:.78rem;color:var(--text2)}\n\n\/* ============ NOTES ============ *\/\n.note{background:var(--blue-light);border-radius:var(--r);padding:14px 18px;font-size:.82rem;color:var(--blue-dark);border-left:3px solid var(--blue);margin:14px 0}\n.note.no{background:var(--orange-light);color:var(--orange-dark);border-color:var(--orange)}\n.note.ng{background:var(--green-light);color:#1e8449;border-color:var(--green)}\n\n\/* ============ TAGS ============ *\/\n.tag{display:inline-block;padding:2px 8px;border-radius:99px;font-size:.68rem;font-weight:600}\n.tag.to{background:var(--orange-light);color:var(--orange-dark)}\n.tag.tb{background:var(--blue-light);color:var(--blue-dark)}\n.tag.tg{background:var(--green-light);color:var(--green)}\n\n\/* ============ FOOTER ============ *\/\n.foot{text-align:center;padding:40px 24px;color:var(--text3);font-size:.8rem;margin-top:32px;border-top:1px solid var(--border)}\n.foot .fm{font-size:1rem;color:var(--orange);font-weight:600;margin-bottom:6px}\n\n\/* ============ RESPONSIVE ============ *\/\n@media(max-width:900px){\n  .duo{grid-template-columns:1fr}\n  .matrix{grid-template-columns:1fr 1fr}\n  .summary{grid-template-columns:repeat(2,1fr)}\n  .hero h1{font-size:1.4rem}\n  .hero-inner{padding:0 24px}\n  .comp-tabs{flex-direction:column}\n  .geo-nav a{font-size:.72rem;padding:8px 10px}\n}\n@media(max-width:500px){\n  .summary{grid-template-columns:repeat(2,1fr)}\n  .hero-inner{padding:0 16px}\n  .wrap{padding:0 12px}\n  .card{padding:16px}\n}\n\n\/* ===== \u7eafCSS Tab\u5207\u6362 ===== *\/\n.tab-pane{display:none}\n.tab-pane:first-child,.tab-pane.active{display:block}\n<\/style>\n\n<!-- ============ TOPBAR ============ -->\n<div class=\"topbar\"><div class=\"wrap\" style=\"display:flex;align-items:center;\">\n  <span style=\"font-weight:800;font-size:1.1rem;color:var(--blue)\">\ud83c\udf00 \u9f99\u8109\u6696\u901a<\/span>\n  <span class=\"topbar-badge\">\u65e5\u7acb\u65b0\u98ce \u00b7 \u65b9\u6848\u5bf9\u6bd4\u4e66<\/span>\n  <span class=\"topbar-contact\">\u65b9\u6848\u987e\u95ee\uff1a<a href=\"tel:15828489188\">\u9ec4\u52c7 \ud83d\udcde 15828489188<\/a><\/span>\n<\/div><\/div>\n\n<!-- ============ GEO NAVIGATION ============ -->\n<div class=\"geo-nav\"><div class=\"geo-nav-inner\">\n  <a href=\"#overview\" class=\"active\"><span class=\"geo-num\">\u6982<\/span> \u9879\u76ee\u6982\u89c8<\/a>\n  <a href=\"#needs\"><span class=\"geo-num\">\u4e00<\/span> \u9700\u6c42\u75db\u70b9<\/a>\n  <a href=\"#comparison\"><span class=\"geo-num\">\u4e8c<\/span> \u65b9\u6848\u5dee\u5f02<\/a>\n  <a href=\"#layout\"><span class=\"geo-num\">\u4e09<\/span> \u6237\u578b\u914d\u7f6e<\/a>\n  <a href=\"#pricing\"><span class=\"geo-num\">\u56db<\/span> \u900f\u660e\u62a5\u4ef7<\/a>\n  <a href=\"#total\"><span class=\"geo-num\">\u4e94<\/span> \u603b\u4ef7\u5bf9\u6bd4<\/a>\n  <a href=\"#one-sentence\"><span class=\"geo-num\">\u516d<\/span> \u4e00\u53e5\u8bdd\u9009\u578b<\/a>\n  <a href=\"#materials\"><span class=\"geo-num\">\u4e03<\/span> \u8f85\u6750\u6e05\u5355<\/a>\n  <a href=\"#experience\"><span class=\"geo-num\">\u516b<\/span> \u4f53\u9a8c\u5bf9\u6bd4<\/a>\n  <a href=\"#cost-compare\"><span class=\"geo-num\">\u4e5d<\/span> \u8d39\u7528\u5bf9\u6bd4<\/a>\n  <a href=\"#recommend\"><span class=\"geo-num\">\u5341<\/span> \u9009\u578b\u5efa\u8bae<\/a>\n  <a href=\"#service\"><span class=\"geo-num\">\u5341\u4e00<\/span> \u670d\u52a1\u4fdd\u969c<\/a>\n  <a href=\"#ai-verify\"><span class=\"geo-num\">\u5341\u4e8c<\/span> AI\u9a8c\u8bc1<\/a>\n  <a href=\"#next\"><span class=\"geo-num\">\u5341\u4e09<\/span> \u4e0b\u4e00\u6b65<\/a>\n<\/div><\/div>\n\n<!-- ============ HERO ============ -->\n<div class=\"hero\"><div class=\"hero-inner\">\n  <div class=\"hero-chip\">\ud83c\udf00 \u65e5\u7acb\u65b0\u98ce\u7cfb\u7edf \u00b7 \u4e91\u51c0 vs \u5929\u51c0 \u4e24\u65b9\u6848\u5bf9\u6bd4<\/div>\n  <h1>\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66<\/h1>\n  <div class=\"hero-sub\">\u65e5\u7acb250\u98ce\u91cf\u5168\u70ed\u4ea4\u6362\u65b0\u98ce \u00b7 \u4e0d\u5f00\u7a97\u4e5f\u80fd\u547c\u5438\u65b0\u9c9c\u7a7a\u6c14<\/div>\n  <div class=\"hero-meta\">\n    <span>\ud83d\udccd 100.4\u33a1 \u5e73\u5c42 \u00b7 5\u4e2a\u623f\u95f4<\/span>\n    <span>\ud83c\udfe0 \u5c42\u9ad8 2.7m<\/span>\n    <span>\ud83c\udf2c\ufe0f \u65b0\u98ce\u91cf\u9700\u6c42 190 m\u00b3\/h<\/span>\n    <span>\u2699\ufe0f \u4e3b\u673a KPI-2525Q3A\/F\uff08\u4e91\u51c0\uff09\/ KPI-2521Q5\/F\uff08\u5929\u51c0\uff09<\/span>\n    <span>\ud83d\udcc5 2026\u5e747\u6708<\/span>\n    <span>\ud83d\udca1 \u8bbe\u8ba1\u4f9d\u636e JGJ\/T440-2018\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300b<\/span>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ SUMMARY CARDS ============ -->\n<div class=\"wrap\"><div class=\"summary\">\n  <div class=\"summary-card\"><div class=\"s-icon\">\ud83c\udfe0<\/div><div class=\"s-val\">100.4\u33a1<\/div><div class=\"s-label\">\u91c7\u6696\u9762\u79ef<\/div><\/div>\n  <div class=\"summary-card\"><div class=\"s-icon\">\ud83d\udeaa<\/div><div class=\"s-val\">5\u95f4\u623f<\/div><div class=\"s-label\">\u9001\u98ce\u53e3\/\u6392\u98ce\u53e3<\/div><\/div>\n  <div class=\"summary-card\"><div class=\"s-icon\">\ud83c\udf00<\/div><div class=\"s-val\">190m\u00b3\/h<\/div><div class=\"s-label\">\u65b0\u98ce\u91cf\u9700\u6c42<\/div><\/div>\n  <div class=\"summary-card\"><div class=\"s-icon\">\u2699\ufe0f<\/div><div class=\"s-val\">250m\u00b3\/h<\/div><div class=\"s-label\">\u4e3b\u673a\u98ce\u91cf<\/div><\/div>\n  <div class=\"summary-card\"><div class=\"s-icon\">\ud83d\udd04<\/div><div class=\"s-val\">80%<\/div><div class=\"s-label\">\u5168\u70ed\u4ea4\u6362\u6548\u7387<\/div><\/div>\n  <div class=\"summary-card\"><div class=\"s-icon\">\u2696\ufe0f<\/div><div class=\"s-val\">2\u65b9\u6848<\/div><div class=\"s-label\">\u5bf9\u6bd4\u914d\u7f6e<\/div><\/div>\n<\/div><\/div>\n\n<!-- ============ \u4e00\u3001\u9700\u6c42\u75db\u70b9 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"overview\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u4e00<\/span><\/div>\n  <h2 class=\"sec-title\">\u4e00\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790<\/h2>\n\n  <!-- \u5ba2\u6237\u4fe1\u606f\u5361 -->\n  <div class=\"card edge-b\">\n    <div class=\"card-head\"><div class=\"card-icon cb\">\ud83d\udccb<\/div><div><div class=\"card-title\">\u5ba2\u6237\u4fe1\u606f\u5361<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u5ba2\u6237\u59d3\u540d<\/td><td class=\"hi\">\u674e\u5148\u751f<\/td><\/tr>\n      <tr><td>\u6237\u578b\u7ed3\u6784<\/td><td>\u5e73\u5c42\uff0c\u4e94\u5ba4\u4e24\u5385\uff08\u5ba2\u9910\u5385+\u4e3b\u5367+\u5367\u5ba4A+\u5367\u5ba4B+\u4e66\u623f\uff09<\/td><\/tr>\n      <tr><td>\u5efa\u7b51\u9762\u79ef<\/td><td>\u7ea6100.4\u33a1<\/td><\/tr>\n      <tr><td>\u5c42\u9ad8<\/td><td>2.7m<\/td><\/tr>\n      <tr><td>\u7cfb\u7edf\u9700\u6c42<\/td><td>\u65e5\u7acb\u65b0\u98ce\u7cfb\u7edf\uff08250\u98ce\u91cf\uff09<\/td><\/tr>\n      <tr><td>\u8bbe\u8ba1\u4f9d\u636e<\/td><td>JGJ\/T440-2018\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300b<\/td><\/tr>\n      <tr><td>\u65b9\u6848\u987e\u95ee<\/td><td>\u9ec4\u52c7 \ud83d\udcde 15828489188<\/td><\/tr>\n      <tr><td>\u65b9\u6848\u65e5\u671f<\/td><td>2026\u5e747\u6708<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <!-- \u7a7a\u95f4\u9762\u79ef\u660e\u7ec6 -->\n  <div class=\"card edge-o\">\n    <div class=\"card-head\"><div class=\"card-icon co\">\ud83d\udcd0<\/div><div><div class=\"card-title\">\u5404\u623f\u95f4\u7a7a\u95f4\u9762\u79ef\u660e\u7ec6<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4\u529f\u80fd<\/th><th>\u623f\u95f4\u9762\u79ef(\u33a1)<\/th><th>\u623f\u95f4\u51c0\u9ad8(m)<\/th><th>\u6362\u6c14\u6b21\u6570(\u6b21\/h)<\/th><th>\u65b0\u98ce\u91cf\u9700\u6c42(m\u00b3\/h)<\/th><th>\u9001\u98ce\u53e3\u6570\u91cf(\u4e2a)<\/th><th>\u6392\u98ce\u53e3\u6570\u91cf(\u4e2a)<\/th><\/tr><\/thead><tbody>\n      <tr><td rowspan=\"5\">\u5e73\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>47.4<\/td><td>2.7<\/td><td>0.7<\/td><td>90<\/td><td>2<\/td><td>2<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>15.9<\/td><td>2.7<\/td><td>0.7<\/td><td>30<\/td><td>1<\/td><td>1<\/td><\/tr>\n      <tr><td>\u5367\u5ba4A<\/td><td>12.3<\/td><td>2.7<\/td><td>0.7<\/td><td>23<\/td><td>1<\/td><td>1<\/td><\/tr>\n      <tr><td>\u5367\u5ba4B<\/td><td>11.8<\/td><td>2.7<\/td><td>0.7<\/td><td>22<\/td><td>1<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e66\u623f<\/td><td>13.0<\/td><td>2.7<\/td><td>0.7<\/td><td>25<\/td><td>1<\/td><td>1<\/td><\/tr>\n      <tr style=\"font-weight:800;background:var(--orange-light);\"><td colspan=\"2\">\u5408\u8ba1<\/td><td class=\"hi\">100.4<\/td><td>\u2014<\/td><td>\u2014<\/td><td class=\"hi\">190<\/td><td class=\"hi\">6<\/td><td class=\"hi\">6<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"note no\" style=\"margin-top:12px\">\ud83d\udccc \u6362\u6c14\u6b21\u6570\u6309JGJ\/T440-2018\u6807\u51c6\u53d6\u503c\uff1a\u4eba\u5747\u5c45\u4f4f\u9762\u79efFp\u226410\u33a1\u65f6\u6362\u6c14\u6b21\u65700.7\u6b21\/h\u3002\u8bbe\u5907\u9009\u578b\u98ce\u91cf = \u8ba1\u7b97\u65b0\u98ce\u91cf \u00d7 \u5f97\u98ce\u7387(\u4e00\u822c\u53d60.8) \u00d7 \u5b89\u5168\u7cfb\u65701.1\u3002\u674e\u5148\u751f\u5bb6\u8ba1\u7b97\u9700\u6c42190m\u00b3\/h\uff0c\u9009\u578b250m\u00b3\/h\u4e3b\u673a\uff0c\u4f59\u91cf\u5145\u8db3\u3002<\/div>\n  <\/div>\n\n  <!-- \u6838\u5fc3\u9700\u6c42 -->\n  <div class=\"card edge-g\">\n    <div class=\"card-head\"><div class=\"card-icon cg\">\ud83c\udfaf<\/div><div><div class=\"card-title\">\u6838\u5fc3\u9700\u6c42\u4e0e\u75db\u70b9\u8bca\u65ad<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th style=\"width:30%\">\u9700\u6c42\u7ef4\u5ea6<\/th><th>\u75db\u70b9\u63cf\u8ff0<\/th><th style=\"width:35%\">\u89e3\u51b3\u65b9\u6848<\/th><\/tr><\/thead><tbody>\n      <tr><td>\ud83c\udf3f <strong>\u5ba4\u5185\u7a7a\u6c14\u54c1\u8d28<\/strong><\/td><td>\u5173\u7a97\u5f00\u7a7a\u8c03\u65f6CO\u2082\u5347\u9ad8\u5bfc\u81f4\u5934\u6655\u3001\u95f7\u70ed\uff0cPM2.5\/\u7532\u919b\u65e0\u7ba1\u63a7<\/td><td>\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u6301\u7eed\u6362\u6c14 + HEPA\u8fc7\u6ee4\u226598%<\/td><\/tr>\n      <tr><td>\u2744\ufe0f <strong>\u51ac\u590f\u4e0d\u8dd1\u51b7\/\u70ed\u91cf<\/strong><\/td><td>\u5f00\u7a97\u6362\u6c14\u5bfc\u81f4\u7a7a\u8c03\/\u5730\u6696\u80fd\u91cf\u5927\u91cf\u6d41\u5931\uff0c\u8d39\u7535\u8d39\u6c14<\/td><td>\u5168\u70ed\u4ea4\u6362\u6548\u738780%\uff0c\u56de\u6536\u6e29\u6e7f\u5ea6\uff0c\u8282\u80fd\u7701\u7535<\/td><\/tr>\n      <tr><td>\ud83d\udd07 <strong>\u9759\u97f3\u8fd0\u884c<\/strong><\/td><td>\u65b0\u98ce\u8bbe\u5907\u566a\u97f3\u5f71\u54cd\u4f11\u606f\u548c\u7761\u7720\u8d28\u91cf<\/td><td>\u6700\u4f4e\u566a\u97f321.5~23.5dB\uff0c\u4f4e\u4e8e\u73af\u5883\u80cc\u666f\u97f3<\/td><\/tr>\n      <tr><td>\ud83d\udcb0 <strong>\u6027\u4ef7\u6bd4<\/strong><\/td><td>\u9884\u7b97\u6709\u9650\uff0c\u5e0c\u671b\u5728\u6ee1\u8db3\u529f\u80fd\u7684\u524d\u63d0\u4e0b\u5408\u7406\u6295\u5165<\/td><td>\u63d0\u4f9b\u4e24\u5957\u65b9\u6848\u68af\u5ea6\u9009\u62e9\uff0c\u53c2\u6570\u900f\u660e\u4f18\u52a3\u6e05\u6670<\/td><\/tr>\n      <tr><td>\ud83d\udd27 <strong>\u5b89\u88c5\u552e\u540e<\/strong><\/td><td>\u9690\u853d\u5de5\u7a0b\u62c5\u5fc3\u5b89\u88c5\u8d28\u91cf\u548c\u540e\u671f\u7ef4\u62a4<\/td><td>\u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5 + 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <!-- \u4e3a\u4ec0\u4e48\u5fc5\u987b\u914d\u65b0\u98ce -->\n  <div class=\"card edge-b\" style=\"margin-top:16px;\">\n    <div class=\"card-head\"><div class=\"card-icon cb\">\ud83d\udca1<\/div><div><div class=\"card-title\">\u4e3a\u4ec0\u4e48\u5173\u7a97\u7a7a\u8c03\u5fc5\u987b\u914d\u65b0\u98ce\uff1f<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u5f00\u7a97\u901a\u98ce<\/th><th>\u7a7a\u6c14\u51c0\u5316\u5668<\/th><th>\u5168\u70ed\u4ea4\u6362\u65b0\u98ce \u2705<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u6392CO\u2082 \/ \u6362\u6c14<\/td><td class=\"hi\">\u2705 \u5f3a<\/td><td>\u274c \u4e0d\u6362\u6c14\uff08\u5185\u5faa\u73af\uff09<\/td><td class=\"hi\">\u2705 \u6301\u7eed\u6362\u6c14<\/td><\/tr>\n      <tr><td>PM2.5\u8fc7\u6ee4<\/td><td>\u274c \u5f15\u5165\u5ba4\u5916\u6c61\u67d3<\/td><td>\u2705 \u5185\u5faa\u73af\u8fc7\u6ee4<\/td><td class=\"hi\">\u2705 HEPA \u226598%<\/td><\/tr>\n      <tr><td>\u51ac\u5b63\u6696\u6c14<\/td><td>\u274c \u6696\u6c14\u8dd1\u5149<\/td><td>\u4e0d\u51b7\u4f46CO\u2082\u98d9\u5347<\/td><td class=\"hi\">\u2705 \u5168\u70ed\u56de\u6536\u70ed\u91cf<\/td><\/tr>\n      <tr><td>\u566a\u97f3<\/td><td>\u5ba4\u5916\u566a\u97f330-50dB<\/td><td>\u4f4e<\/td><td class=\"hi\">\u2705 \u4f4e\u81f321.5dB<\/td><\/tr>\n      <tr><td>\u6210\u90fd\u51ac\u5b63\u7279\u70b9<\/td><td colspan=\"3\" class=\"hi\">\u6210\u90fd\u51ac\u5929\u6e7f\u5ea6\u5927\uff0c\u663e\u70ed\u4ea4\u6362\u4f1a\u8ba9\u5ba4\u5185\u8d8a\u6765\u8d8a\u5e72\u3002\u65e5\u7acb<strong>\u5168\u70ed\u4ea4\u6362\u82af<\/strong>\u540c\u65f6\u56de\u6536\u6e29\u6e7f\u5ea6\uff0c\u7113\u4ea4\u6362\u6548\u738780%\uff0c\u8ba9\u65b0\u98ce\u771f\u6b63\"\u6e29\u6696\u9001\u8fdb\u6765\"<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u4e8c\u3001\u4e24\u5927\u65b9\u6848\u6838\u5fc3\u5dee\u5f02 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"comparison\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u4e8c<\/span><\/div>\n  <h2 class=\"sec-title\">\u4e8c\u3001\u65e5\u7acb\u65b0\u98ce\u00b7\u4e91\u51c0 vs \u5929\u51c0 \u4e24\u5927\u65b9\u6848\u6838\u5fc3\u5dee\u5f02<\/h2>\n\n  <!-- \u65b9\u6848\u5361\u7247 duo -->\n  <div class=\"duuo duo\">\n    <div class=\"plan-card\">\n      <div class=\"p-icon\" style=\"background:var(--blue-light);color:var(--blue)\">\u2601\ufe0f<\/div>\n      <div class=\"p-name\">\u65b9\u6848\u4e00 \u00b7 \u4e91\u51c0II 250<\/div>\n      <div class=\"p-price\">11,500 <small>\u5143<\/small><\/div>\n      <ul>\n        <li>KPI-2525Q3A\/F \u4e91\u51c0\u7cfb\u5217<\/li>\n        <li>\u6027\u4ef7\u6bd4\u4f18\u9009\uff0c\u4ef7\u683c\u66f4\u53cb\u597d<\/li>\n        <li>\u6807\u51c6\u7ebf\u63a7\u5c4f\u663e\u793a<\/li>\n        <li>WiFi\u667a\u80fd\u63a7\u5236<\/li>\n        <li>\u57fa\u7840\u8054\u52a8\u529f\u80fd<\/li>\n        <li>HEPA\u8fc7\u6ee4\u226598%<\/li>\n        <li>\u6ee4\u82af10\u5e74\u514d\u66f4\u6362<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"plan-card best\">\n      <div class=\"p-icon\" style=\"background:var(--green-light);color:var(--green)\">\ud83c\udf1f<\/div>\n      <div class=\"p-name\">\u65b9\u6848\u4e8c \u00b7 \u5929\u51c0Q5 250<\/div>\n      <div class=\"p-price\">14,600 <small>\u5143<\/small><\/div>\n      <ul>\n        <li>KPI-2521Q5\/F \u5929\u51c0\u7cfb\u5217<\/li>\n        <li>\u4e13\u4e1a\u7ea7\u914d\u7f6e\uff0c\u4f53\u9a8c\u5347\u7ea7<\/li>\n        <li>\u8d85\u5927\u5c4f\u00b7\u7a7a\u6c14\u53ef\u89c6\u5316\u5927\u5c4f<\/li>\n        <li>WiFi\u667a\u80fd\u63a7\u5236<\/li>\n        <li>\u53ef\u8054\u52a8\u4e2d\u592e\u7a7a\u8c03<\/li>\n        <li>HEPA\u8fc7\u6ee4\u226598%<\/li>\n        <li>\u6ee4\u82af10\u5e74\u514d\u66f4\u6362<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <!-- \u8be6\u7ec6\u5dee\u5f02\u8868 -->\n  <div class=\"card edge-o\">\n    <div class=\"card-head\"><div class=\"card-icon co\">\u2696\ufe0f<\/div><div><div class=\"card-title\">\u4e91\u51c0II vs \u5929\u51c0Q5 \u5173\u952e\u5dee\u5f02\u5bf9\u7167\u8868<\/div><div class=\"card-sub\">\u540c\u4e00\u98ce\u91cf\u7ea7\u522b\uff0c\u4e0d\u540c\u5b9a\u4f4d\u2014\u2014\u9009\u5bf9\u4e0d\u9009\u8d35<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u5bf9\u6bd4\u9879<\/th><th>\u65b9\u6848\u4e00\uff1a\u4e91\u51c0II 250\uff08KPI-2525Q3A\/F\uff09<\/th><th>\u65b9\u6848\u4e8c\uff1a\u5929\u51c0Q5 250\uff08KPI-2521Q5\/F\uff09<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u7cfb\u5217\u5b9a\u4f4d<\/td><td>\u4e91\u51c0\u7cfb\u5217\uff1a\u6027\u4ef7\u6bd4\u4f18\u9009<\/td><td class=\"hi\">\u5929\u51c0\u7cfb\u5217\uff1a\u4e13\u4e1a\u7ea7\u65b0\u98ce\u673a<\/td><\/tr>\n      <tr><td>\u578b\u53f7<\/td><td>KPI-2525Q3A\/F<\/td><td class=\"hi\">KPI-2521Q5\/F<\/td><\/tr>\n      <tr><td>\u989d\u5b9a\u98ce\u91cf<\/td><td>250 m\u00b3\/h<\/td><td class=\"hi\">250 m\u00b3\/h<\/td><\/tr>\n      <tr><td>\u4e09\u6863\u98ce\u91cf<\/td><td>250 \/ 170 \/ 120 m\u00b3\/h<\/td><td class=\"hi\">250 \/ 170 \/ 120 m\u00b3\/h<\/td><\/tr>\n      <tr><td>\u529f\u7387\uff08\u4e09\u6863\uff09<\/td><td>162 \/ 106 \/ 76 W<\/td><td class=\"hi\">162 \/ 106 \/ 76 W<\/td><\/tr>\n      <tr><td>\u566a\u97f3\uff08\u4e09\u6863\uff09<\/td><td>32.5 \/ 28.5 \/ 23.5 dB(A)<\/td><td class=\"hi\">\u226432 \/ \u226428 \/ \u226423 dB(A)<\/td><\/tr>\n      <tr><td>\u673a\u5916\u9759\u538b\uff08\u4e09\u6863\uff09<\/td><td>80 \/ 50 \/ 30 Pa<\/td><td class=\"hi\">80 \/ 50 \/ 30 Pa<\/td><\/tr>\n      <tr><td>\u7113\u4ea4\u6362\u6548\u7387<\/td><td>80%\uff08\u5168\u70ed\u4ea4\u6362\uff09<\/td><td class=\"hi\">80%\uff08\u5168\u70ed\u4ea4\u6362\uff09<\/td><\/tr>\n      <tr><td>PM2.5\u51c0\u5316<\/td><td>HEPA \u226598%<\/td><td class=\"hi\">HEPA \u226598%<\/td><\/tr>\n      <tr><td>\u7ebf\u63a7\u5668\u5c4f\u5e55<\/td><td>\u6807\u51c6\u5c4f\uff08\u57fa\u7840\u663e\u793a\uff09<\/td><td class=\"hi\">\u8d85\u5927\u5c4f\u00b7\u7a7a\u6c14\u53ef\u89c6\u5316\uff08\u5b9e\u65f6\u6e29\u5ea6\/\u6e7f\u5ea6\/CO\u2082\/PM2.5\uff09<\/td><\/tr>\n      <tr><td>WiFi\u63a7\u5236<\/td><td>\u2705 \u652f\u6301<\/td><td class=\"hi\">\u2705 \u652f\u6301<\/td><\/tr>\n      <tr><td>\u667a\u80fd\u8054\u52a8<\/td><td>\u57fa\u7840\u8054\u52a8<\/td><td class=\"hi\">\u53ef\u8054\u52a8\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/td><\/tr>\n      <tr><td>\u6ee4\u82af\u5bff\u547d<\/td><td>10\u5e74\u514d\u66f4\u6362<\/td><td class=\"hi\">10\u5e74\u514d\u66f4\u6362<\/td><\/tr>\n      <tr><td>\u6cd5\u5170\u5c3a\u5bf8<\/td><td>\u03c6144mm<\/td><td class=\"hi\">\u03c6144mm<\/td><\/tr>\n      <tr><td>\u8bbe\u5907\u5c3a\u5bf8<\/td><td>735\u00d7962\u00d7220 mm<\/td><td class=\"hi\">735\u00d7962\u00d7220 mm<\/td><\/tr>\n      <tr><td>\u521d\u6295\u8d44<\/td><td class=\"pr\">11,500\u5143<\/td><td class=\"hi pr\">14,600\u5143<\/td><\/tr>\n      <tr><td>\u9002\u5408\u4eba\u7fa4<\/td><td>\u8ffd\u6c42\u6027\u4ef7\u6bd4\u7684\u5bb6\u5ead<\/td><td class=\"hi\">\u8ffd\u6c42\u4e13\u4e1a\u7ea7\u4f53\u9a8c\u7684\u5bb6\u5ead<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"note ng\" style=\"margin-top:12px\">\ud83d\udcca <strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a\u4e24\u5957\u65b9\u6848\u7684<strong>\u98ce\u91cf\u3001\u566a\u97f3\u3001\u51c0\u5316\u6548\u7387\u3001\u70ed\u4ea4\u6362\u6027\u80fd\u5b8c\u5168\u4e00\u81f4<\/strong>\u3002\u5dee\u5f02\u4e3b\u8981\u5728\uff1a\u5929\u51c0Q5\u7684<strong>\u5c4f\u5e55\u66f4\u5927\u66f4\u667a\u80fd<\/strong>\uff08\u53ef\u89c6\u5316\u7a7a\u6c14\u8d28\u91cf\u6570\u636e\uff09\u3001<strong>\u8054\u52a8\u80fd\u529b\u66f4\u5f3a<\/strong>\uff08\u53ef\u4e0e\u4e2d\u592e\u7a7a\u8c03\u8054\u52a8\uff09\u3001<strong>\u5b9a\u4f4d\u66f4\u9ad8\u7aef<\/strong>\u3002\u5982\u679c\u9884\u7b97\u5141\u8bb8\u4e14\u6ce8\u91cd\u667a\u80fd\u5316\u4f53\u9a8c\uff0c\u5929\u51c0\u662f\u66f4\u597d\u7684\u9009\u62e9\uff1b\u5982\u679c\u8ffd\u6c42\u5b9e\u7528\u591f\u7528\uff0c\u4e91\u51c0\u6027\u4ef7\u6bd4\u66f4\u9ad8\u3002<\/div>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u4e09\u3001\u6237\u578b\u7ba1\u8def\u914d\u7f6e ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"layout\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u4e09<\/span><\/div>\n  <h2 class=\"sec-title\">\u4e09\u3001\u5404\u623f\u95f4\u7ba1\u8def\u914d\u7f6e\u660e\u7ec6<\/h2>\n\n  <div class=\"card edge-b\">\n    <div class=\"card-head\"><div class=\"card-icon cb\">\ud83d\udd27<\/div><div><div class=\"card-title\">\u65b0\u98ce\u4e3b\u673a\u53c2\u6570\uff08KPI-2525Q3A\/F \u4e91\u51c0 \/ KPI-2521Q5\/F \u5929\u51c0\uff09<\/div><div class=\"card-sub\">250\u98ce\u91cf \u00b7 \u4e24\u65b9\u6848\u7edf\u4e00\u98ce\u91cf \u00b7 \u65e5\u7acb\u539f\u88c5\u8fdb\u53e3<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u53c2\u6570\u9879<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u65b0\u98ce\u673a\u578b\u53f7<\/td><td class=\"hi\">KPI-2525Q3A\/F\uff08\u4e91\u51c0\uff09\/ KPI-2521Q5\/F\uff08\u5929\u51c0\uff09<\/td><\/tr>\n      <tr><td>\u8bbe\u5907\u98ce\u91cf(m\u00b3\/h)<\/td><td>250 \/ 170 \/ 120\uff08\u4e09\u6863\uff09<\/td><\/tr>\n      <tr><td>\u8bbe\u5907\u529f\u7387(W)<\/td><td>162 \/ 106 \/ 76\uff08\u4e09\u6863\uff09<\/td><\/tr>\n      <tr><td>\u8bbe\u5907\u566a\u97f3dB(A)<\/td><td>32.5 \/ 28.5 \/ 23.5\uff08\u4e09\u6863\uff09<\/td><\/tr>\n      <tr><td>\u673a\u5916\u9759\u538b(Pa)<\/td><td>80 \/ 50 \/ 30\uff08\u4e09\u6863\uff09<\/td><\/tr>\n      <tr><td>\u6cd5\u5170\u5c3a\u5bf8(mm)<\/td><td>\u03c6144<\/td><\/tr>\n      <tr><td>\u8bbe\u5907\u5c3a\u5bf8(mm)<\/td><td>\u957f735 \u00d7 \u5bbd962 \u00d7 \u9ad8220<\/td><\/tr>\n      <tr><td>\u7113\u4ea4\u6362\u6548\u7387<\/td><td>80%\uff08\u5168\u70ed\u4ea4\u6362\uff09<\/td><\/tr>\n      <tr><td>PM2.5\u8fc7\u6ee4\u7b49\u7ea7<\/td><td>HEPA \u226598%<\/td><\/tr>\n      <tr><td>\u9002\u7528\u9762\u79ef<\/td><td>80-120\u33a1<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card edge-o\" style=\"margin-top:16px;\">\n    <div class=\"card-head\"><div class=\"card-icon co\">\ud83c\udfe0<\/div><div><div class=\"card-title\">\u5404\u623f\u95f4\u9001\u98ce\/\u6392\u98ce\u53e3\u914d\u7f6e\u660e\u7ec6<\/div><div class=\"card-sub\">100.4\u33a1 \u00b7 5\u4e2a\u623f\u95f4 \u00b7 6\u90016\u6392\u517112\u4e2a\u98ce\u53e3<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u51c0\u9ad8(m)<\/th><th>\u65b0\u98ce\u91cf(m\u00b3\/h)<\/th><th>\u9001\u98ce\u53e3<\/th><th>\u6392\u98ce\u53e3<\/th><th>\u7ba1\u5f84<\/th><\/tr><\/thead><tbody>\n      <tr><td rowspan=\"5\">\u5e73\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>47.4<\/td><td>2.7<\/td><td>90<\/td><td>2\u4e2a<\/td><td>2\u4e2a<\/td><td>De75\u4e3b\u7ba1+De50\u652f\u7ba1<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>15.9<\/td><td>2.7<\/td><td>30<\/td><td>1\u4e2a<\/td><td>1\u4e2a<\/td><td>De50<\/td><\/tr>\n      <tr><td>\u5367\u5ba4A<\/td><td>12.3<\/td><td>2.7<\/td><td>23<\/td><td>1\u4e2a<\/td><td>1\u4e2a<\/td><td>De50<\/td><\/tr>\n      <tr><td>\u5367\u5ba4B<\/td><td>11.8<\/td><td>2.7<\/td><td>22<\/td><td>1\u4e2a<\/td><td>1\u4e2a<\/td><td>De50<\/td><\/tr>\n      <tr><td>\u4e66\u623f<\/td><td>13.0<\/td><td>2.7<\/td><td>25<\/td><td>1\u4e2a<\/td><td>1\u4e2a<\/td><td>De50<\/td><\/tr>\n      <tr style=\"font-weight:800;background:var(--orange-light);\">\n        <td colspan=\"2\">\u5408\u8ba1<\/td><td class=\"hi\">100.4<\/td><td>\u2014<\/td><td class=\"hi\">190<\/td><td class=\"hi\">6\u4e2a<\/td><td class=\"hi\">6\u4e2a<\/td><td>\u2014<\/td>\n      <\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u56db\u3001\u900f\u660e\u62a5\u4ef7 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"pricing\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u56db<\/span><\/div>\n  <h2 class=\"sec-title\">\u56db\u3001\u900f\u660e\u62a5\u4ef7\u660e\u7ec6<\/h2>\n\n  <div class=\"comp-tabs\" id=\"priceCompTabs\">\n    <button class=\"comp-tab active\" onclick=\"showPriceTab(event,0)\"><span class=\"t-tag t1\">\u65b9\u6848\u4e00<\/span><span class=\"t-name\">\u4e91\u51c0II 250 \u6027\u4ef7\u6bd4<\/span><span class=\"t-price\">\u00a511,500<\/span><\/button>\n    <button class=\"comp-tab\" onclick=\"showPriceTab(event,1)\"><span class=\"t-tag t2\">\u65b9\u6848\u4e8c<\/span><span class=\"t-name\">\u5929\u51c0Q5 250 \u4e13\u4e1a\u7ea7<\/span><span class=\"t-price\">\u00a514,600<\/span><span class=\"t-recommend\">\ud83d\udc4d<\/span><\/button>\n  <\/div>\n\n  <div class=\"slider\" id=\"priceSlider\">\n    <div class=\"slider-track\" id=\"priceTrack\" style=\"transform:translateX(0%);\">\n      <!-- \u65b9\u6848\u4e00\u62a5\u4ef7 -->\n      <div class=\"slider-slide\">\n        <div class=\"card edge-o\">\n          <table class=\"tbl\"><thead><tr><th>\u5e8f\u53f7<\/th><th>\u9879\u76ee<\/th><th>\u89c4\u683c\/\u8bf4\u660e<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr><\/thead><tbody>\n            <tr><td>1<\/td><td>\u65b0\u98ce\u673a\u4e3b\u673a<\/td><td>\u65e5\u7acb KPI-2525Q3A\/F \u4e91\u51c0II 250<\/td><td>1\u53f0<\/td><td class=\"pr\">5,500<\/td><td class=\"pr\">5,500<\/td><\/tr>\n            <tr><td>2<\/td><td>PVC\u98ce\u7ba1<\/td><td>De75\u4e3b\u7ba1+De50\u652f\u7ba1\uff08\u542b\u5f2f\u5934\/\u4e09\u901a\/\u53d8\u5f84\uff09<\/td><td>1\u5957<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>3<\/td><td>\u9001\u98ce\u53e3<\/td><td>ABS\u5706\u5f62\u51fa\u98ce\u53e3\uff08\u53ef\u8c03\u65b9\u5411\uff09<\/td><td>6\u4e2a<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>4<\/td><td>\u6392\u98ce\u53e3<\/td><td>ABS\u5706\u5f62\u56de\u98ce\u53e3\uff08\u5e26\u683c\u6805\uff09<\/td><td>6\u4e2a<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>5<\/td><td>\u98ce\u9600<\/td><td>\u624b\u52a8\u98ce\u9600\uff08\u5404\u652f\u8def\u72ec\u7acb\u8c03\u8282\uff09<\/td><td>6\u5957<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>6<\/td><td>\u7ebf\u63a7\u5668<\/td><td>\u65e5\u7acb\u6807\u914d\u7ebf\u63a7\u5668<\/td><td>1\u4e2a<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--text3);\">\u542b\u5728\u4e3b\u673a<\/td><\/tr>\n          <tr><td>7<\/td><td>\u5b89\u88c5\u8f85\u6750<\/td><td>\u540a\u67b6\/\u5bc6\u5c01\u80f6\/\u4fdd\u6e29\u68c9\/\u7a7f\u5899\u5957\u7ba1\u7b49<\/td><td>1\u6279<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n          <tr><td>8<\/td><td>\u5b89\u88c5\u8c03\u8bd5\u8d39<\/td><td>\u5b89\u88c5+\u7ba1\u9053\u8fde\u63a5+\u6ce8\u6c34\u6392\u6c14+\u8fd0\u884c\u8c03\u8bd5<\/td><td>1\u9879<\/td><td class=\"pr\">6,000<\/td><td class=\"pr\">6,000<\/td><\/tr>\n          <tr style=\"font-weight:800;background:var(--orange-light);\"><td colspan=\"5\">\u65b9\u6848\u4e00\u00b7\u4e91\u51c0II \u603b\u8ba1<\/td><td class=\"hi\">11,500<\/td><\/tr>\n        <\/tbody><\/table>\n        <div class=\"note no\" style=\"margin-top:12px\">\ud83d\udccc \u4ee5\u4e0a\u4e3a\u65b9\u6848\u4e00\u00b7\u4e91\u51c0II 250\u5b8c\u6574\u62a5\u4ef7\u3002\u7ba1\u8def\/\u98ce\u53e3\/\u98ce\u9600\/\u8f85\u6750\u5747\u4e3a\u5305\u5de5\u5305\u6599\uff08\u542b\u5728\u5b89\u88c5\u8c03\u8bd5\u8d39\u4e2d\uff09\uff0c\u4e3b\u673a\u4e3a\u65e5\u7acb\u539f\u88c5\u6b63\u54c1\uff0c\u4eab\u53d7\u5382\u5bb6\u8d28\u4fdd\u3002<\/div>\n      <\/div>\n\n      <!-- \u65b9\u6848\u4e8c\u62a5\u4ef7 -->\n      <div class=\"slider-slide\">\n        <div class=\"card edge-g\">\n          <table class=\"tbl\"><thead><tr><th>\u5e8f\u53f7<\/th><th>\u9879\u76ee<\/th><th>\u89c4\u683c\/\u8bf4\u660e<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u5c0f\u8ba1(\u5143)<\/th><\/tr><\/thead><tbody>\n            <tr><td>1<\/td><td>\u65b0\u98ce\u673a\u4e3b\u673a<\/td><td>\u65e5\u7acb KPI-2521Q5\/F \u5929\u51c0Q5 250<\/td><td>1\u53f0<\/td><td class=\"pr\">8,600<\/td><td class=\"pr\">8,600<\/td><\/tr>\n            <tr><td>2<\/td><td>PVC\u98ce\u7ba1<\/td><td>De75\u4e3b\u7ba1+De50\u652f\u7ba1\uff08\u542b\u5f2f\u5934\/\u4e09\u901a\/\u53d8\u5f84\uff09<\/td><td>1\u5957<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>3<\/td><td>\u9001\u98ce\u53e3<\/td><td>ABS\u5706\u5f62\u51fa\u98ce\u53e3\uff08\u53ef\u8c03\u65b9\u5411\uff09<\/td><td>6\u4e2a<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>4<\/td><td>\u6392\u98ce\u53e3<\/td><td>ABS\u5706\u5f62\u56de\u98ce\u53e3\uff08\u5e26\u683c\u6805\uff09<\/td><td>6\u4e2a<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>5<\/td><td>\u98ce\u9600<\/td><td>\u624b\u52a8\u98ce\u9600\uff08\u5404\u652f\u8def\u72ec\u7acb\u8c03\u8282\uff09<\/td><td>6\u5957<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n            <tr><td>6<\/td><td>\u7ebf\u63a7\u5668<\/td><td>\u65e5\u7acb\u8d85\u5927\u5c4f\u53ef\u89c6\u7ebf\u63a7\u5668<\/td><td>1\u4e2a<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--text3);\">\u542b\u5728\u4e3b\u673a<\/td><\/tr>\n          <tr><td>7<\/td><td>\u5b89\u88c5\u8f85\u6750<\/td><td>\u540a\u67b6\/\u5bc6\u5c01\u80f6\/\u4fdd\u6e29\u68c9\/\u7a7f\u5899\u5957\u7ba1\u7b49<\/td><td>1\u6279<\/td><td colspan=\"2\" style=\"text-align:center;color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/td><\/tr>\n          <tr><td>8<\/td><td>\u5b89\u88c5\u8c03\u8bd5\u8d39<\/td><td>\u5b89\u88c5+\u7ba1\u9053\u8fde\u63a5+\u8fd0\u884c\u8c03\u8bd5+\u8054\u52a8\u8bbe\u7f6e<\/td><td>1\u9879<\/td><td class=\"pr\">6,000<\/td><td class=\"pr\">6,000<\/td><\/tr>\n          <tr style=\"font-weight:800;background:var(--orange-light);\"><td colspan=\"5\">\u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5 \u603b\u8ba1<\/td><td class=\"hi\">14,600<\/td><\/tr>\n        <\/tbody><\/table>\n        <div class=\"note ng\" style=\"margin-top:12px\">\ud83d\udccc \u4ee5\u4e0a\u4e3a\u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5 250\u5b8c\u6574\u62a5\u4ef7\u3002\u7ba1\u8def\/\u98ce\u53e3\/\u98ce\u9600\/\u8f85\u6750\u5747\u4e3a\u5305\u5de5\u5305\u6599\uff08\u542b\u5728\u5b89\u88c5\u8c03\u8bd5\u8d39\u4e2d\uff09\u3002\u5929\u51c0\u4e3b\u673a\u6bd4\u4e91\u51c0\u8d35\u7ea63,100\u5143\uff0c\u5dee\u4ef7\u4e3b\u8981\u6765\u81ea\u8d85\u5927\u5c4f\u53ef\u89c6\u5316\u63a7\u5236\u5668\u548c\u66f4\u5f3a\u7684\u8054\u52a8\u80fd\u529b\u3002\u5b89\u88c5\u8c03\u8bd5\u8d39\u7edf\u4e006,000\u5143\u3002<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u4e94\u3001\u603b\u4ef7\u5bf9\u6bd4\u77e9\u9635 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"total\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u4e94<\/span><\/div>\n  <h2 class=\"sec-title\">\u4e94\u3001\u4e24\u65b9\u6848\u6700\u7ec8\u603b\u4ef7\u5bf9\u6bd4<\/h2>\n\n  <div class=\"matrix\">\n    <div class=\"mx hd\">\u8d39\u7528\u9879<\/div><div class=\"mx hd\">\u65b9\u6848\u4e00\uff08\u4e91\u51c0II 250\uff09<\/div><div class=\"mx hd\">\u65b9\u6848\u4e8c\uff08\u5929\u51c0Q5 250\uff09<\/div>\n    <div class=\"mx lb\">\u65b0\u98ce\u673a\u4e3b\u673a<\/div><div class=\"mx\">5,500<\/div><div class=\"mx best\">8,600<\/div>\n    <div class=\"mx lb\">\u7ba1\u8def\/\u98ce\u53e3\/\u98ce\u9600\/\u8f85\u6750<\/div><div class=\"mx\" style=\"color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/div><div class=\"mx\" style=\"color:var(--green);font-weight:600;\">\u5305\u5de5\u5305\u6599<\/div>\n    <div class=\"mx lb\">\u5b89\u88c5\u8c03\u8bd5\u8d39\uff08\u542b\u7ba1\u8def\u65bd\u5de5\uff09<\/div><div class=\"mx\">6,000<\/div><div class=\"mx\">6,000<\/div>\n    <div class=\"mx lb\" style=\"font-weight:800;font-size:.92rem;\">\u603b\u8ba1<\/div>\n    <div class=\"mx best\" style=\"font-weight:800;font-size:1.05rem;\">11,500<\/div>\n    <div class=\"mx\" style=\"font-weight:800;font-size:1.05rem;\">14,600<\/div>\n    <div class=\"mx lb\">\u4e0e\u65b9\u6848\u4e00\u5dee\u4ef7<\/div>\n    <div class=\"mx\">\u57fa\u51c6<\/div><div class=\"mx\" style=\"color:#e67e22;\">+3,100<\/div>\n  <\/div>\n\n  <div class=\"note nb\" style=\"margin-top:12px\">\ud83d\udca1 <strong>\u5dee\u4ef7\u89e3\u8bfb<\/strong>\uff1a\u4e24\u65b9\u6848\u4ec5\u4e3b\u673a\u4e0d\u540c\uff0c\u7ba1\u8def\/\u98ce\u53e3\/\u98ce\u9600\/\u8f85\u6750\u5747\u4e3a\u5305\u5de5\u5305\u6599\uff08\u542b\u5728\u5b89\u88c5\u8c03\u8bd5\u8d39\u4e2d\uff09\u3002\u5929\u51c0\u6bd4\u4e91\u51c0\u591a\u82b13,100\u5143\uff0c\u6362\u6765\u7684\u662f\uff1a\u2460 \u8d85\u5927\u5c4f\u7a7a\u6c14\u53ef\u89c6\u5316\uff08\u5b9e\u65f6\u770b\u5230\u6e29\u5ea6\/\u6e7f\u5ea6\/CO\u2082\/PM2.5\u6570\u503c\uff09\uff1b\u2461 \u66f4\u5f3a\u7684\u8054\u52a8\u80fd\u529b\uff08\u53ef\u4e0e\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u8054\u52a8\uff09\uff1b\u2462 \u4e13\u4e1a\u7ea7\u7684\u54c1\u724c\u5b9a\u4f4d\u548c\u540e\u7eed\u4ef7\u503c\u3002\u5b89\u88c5\u8c03\u8bd5\u8d39\u7edf\u4e006,000\u5143\uff08\u542b\u7ba1\u8def\u65bd\u5de5+\u8fd0\u884c\u8c03\u8bd5+\u8054\u52a8\u8bbe\u7f6e\uff09\u3002<\/div>\n<\/div><\/div>\n\n<!-- ============ \u516d\u3001\u4e00\u53e5\u8bdd\u9009\u578b ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"one-sentence\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u516d<\/span><\/div>\n  <h2 class=\"sec-title\">\u516d\u3001\u4e00\u53e5\u8bdd\u5feb\u901f\u9009\u578b<\/h2>\n\n  <div class=\"card edge-o\">\n    <table class=\"tbl\"><thead><tr><th>\u5982\u679c\u60a8\u8fd9\u6837\u60f3<\/th><th>\u63a8\u8350<\/th><th>\u4ef7\u683c<\/th><th>\u7406\u7531<\/th><\/tr><\/thead><tbody>\n      <tr><td>\"\u6211\u5c31\u60f3\u8981\u6700\u5b9e\u60e0\u7684\u65b0\u98ce\"<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e00<\/td><td>11,500\u5143<\/td><td>\u4e91\u51c0II\u6027\u4ef7\u6bd4\u9ad8\uff0c\u98ce\u91cf\/\u51c0\u5316\/\u70ed\u4ea4\u6362\u4e00\u6837\u597d<\/td><\/tr>\n      <tr><td>\"\u6211\u60f3\u770b\u5f97\u5230\u7a7a\u6c14\u8d28\u91cf\u7684\u5b9e\u65f6\u6570\u636e\"<\/td><td>\u65b9\u6848\u4e8c<\/td><td>14,600\u5143<\/td><td>\u5929\u51c0\u8d85\u5927\u5c4f\u53ef\u89c6\u5316\uff0cCO\u2082\/PM2.5\u4e00\u76ee\u4e86\u7136<\/td><\/tr>\n      <tr><td>\"\u6211\u88c5\u4e86\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff0c\u5e0c\u671b\u65b0\u98ce\u80fd\u8054\u52a8\"<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e8c<\/td><td>14,600\u5143<\/td><td>\u5929\u51c0\u652f\u6301\u4e0e\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u80fd\u8054\u52a8<\/td><\/tr>\n      <tr><td>\"\u9884\u7b97\u5145\u8db3\uff0c\u8981\u6700\u597d\u7684\u4f53\u9a8c\"<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e8c<\/td><td>14,600\u5143<\/td><td>\u4e13\u4e1a\u7ea7\u914d\u7f6e\uff0c\u5c4f\u5e55+\u8054\u52a8+\u989c\u503c\u5168\u9762\u9886\u5148<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u4e03\u3001\u8f85\u6750\u6e05\u5355 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"materials\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u4e03<\/span><\/div>\n  <h2 class=\"sec-title\">\u4e03\u3001\u9644\uff1a\u8f85\u6750\u6e05\u5355\u5bf9\u6bd4\uff08\u4e24\u65b9\u6848\u901a\u7528\u90e8\u5206\uff09<\/h2>\n\n  <div class=\"card edge-b\">\n    <table class=\"tbl\"><thead><tr><th>\u7c7b\u522b<\/th><th>\u6750\u6599\u540d\u79f0<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u54c1\u724c\/\u5907\u6ce8<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u98ce\u7ba1<\/td><td>PVC\u5706\u7ba1<\/td><td>De75\u4e3b\u7ba1<\/td><td>\u7ea615\u7c73<\/td><td>\u56fd\u6807\u539a\u5ea6\uff0c\u964d\u566a\u5904\u7406<\/td><\/tr>\n      <tr><td>\u98ce\u7ba1<\/td><td>PVC\u5706\u7ba1<\/td><td>De50\u652f\u7ba1<\/td><td>\u7ea625\u7c73<\/td><td>\u56fd\u6807\u539a\u5ea6\uff0c\u964d\u566a\u5904\u7406<\/td><\/tr>\n      <tr><td>\u98ce\u53e3<\/td><td>ABS\u51fa\u98ce\u53e3<\/td><td>\u03c6100 \u5706\u5f62\u53ef\u8c03<\/td><td>6\u4e2a<\/td><td>360\u00b0\u98ce\u5411\u8c03\u8282<\/td><\/tr>\n      <tr><td>\u98ce\u53e3<\/td><td>ABS\u56de\u98ce\u53e3<\/td><td>\u03c6150 \u5e26\u683c\u6805<\/td><td>6\u4e2a<\/td><td>\u9632\u866b\u8bbe\u8ba1<\/td><\/tr>\n      <tr><td>\u9600\u95e8<\/td><td>\u624b\u52a8\u98ce\u9600<\/td><td>De50<\/td><td>6\u5957<\/td><td>\u6bcf\u8def\u72ec\u7acb\u8c03\u8282\u98ce\u91cf<\/td><\/tr>\n      <tr><td>\u914d\u4ef6<\/td><td>PVC\u53d8\u5f84\/\u5f2f\u5934\/\u4e09\u901a<\/td><td>\u914d\u5957<\/td><td>1\u5957<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u5bc6\u5c01<\/td><td>\u94dd\u7b94\u5bc6\u5c01\u80f6\u5e26<\/td><td>48mm\u5bbd<\/td><td>2\u5377<\/td><td>\u63a5\u53e3\u5904\u5bc6\u5c01\u9632\u6f0f\u98ce<\/td><\/tr>\n      <tr><td>\u4fdd\u6e29<\/td><td>\u6a61\u5851\u4fdd\u6e29\u68c9<\/td><td>20mm\u539a<\/td><td>\u7ea65\u33a1<\/td><td>\u9632\u6b62\u7ed3\u9732<\/td><\/tr>\n      <tr><td>\u56fa\u5b9a<\/td><td>\u9540\u950c\u540a\u67b6<\/td><td>M8\/M10<\/td><td>1\u5957<\/td><td>\u627f\u91cd\u5b89\u5168<\/td><\/tr>\n      <tr><td>\u7a7f\u5899<\/td><td>PVC\u7a7f\u5899\u5957\u7ba1<\/td><td>\u03c6160<\/td><td>2\u4e2a<\/td><td>\u5916\u5899\u8fdb\u98ce\/\u6392\u98ce\u5b54<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"note nb\" style=\"margin-top:12px\">\ud83d\udccc \u4ee5\u4e0a\u8f85\u6750\u4e24\u65b9\u6848\u901a\u7528\u3002\u6240\u6709\u6750\u6599\u8fdb\u573a\u65f6\u5c06\u4e0e\u5ba2\u6237\u5171\u540c\u9a8c\u6536\u54c1\u724c\u578b\u53f7\u89c4\u683c\uff0c\u786e\u8ba4\u65e0\u8bef\u540e\u65b9\u53ef\u65bd\u5de5\u3002<\/div>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u516b\u3001\u4f53\u9a8c\u516d\u7ef4\u5ea6 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"experience\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u516b<\/span><\/div>\n  <h2 class=\"sec-title\">\u516b\u3001\u4f53\u9a8c\u516d\u7ef4\u5ea6\u8bc4\u5206<\/h2>\n\n  <div class=\"card edge-g\">\n    <table class=\"tbl\"><thead><tr><th>\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00\u00b7\u4e91\u51c0II<\/th><th>\u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5<\/th><\/tr><\/thead><tbody>\n      <tr><td>\ud83c\udf2c\ufe0f \u6362\u6c14\u6548\u679c<\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><\/tr>\n      <tr><td>\ud83e\udee7 \u51c0\u5316\u80fd\u529b<\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><\/tr>\n      <tr><td>\ud83d\udd07 \u9759\u97f3\u7a0b\u5ea6<\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><\/tr>\n      <tr><td>\u267b\ufe0f \u8282\u80fd\u7701\u7535<\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/div><\/td><\/tr>\n      <tr><td>\ud83d\udcf1 \u667a\u80fd\u64cd\u63a7<\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st\">\u2605<\/span><\/div><\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/td><\/tr>\n      <tr><td>\ud83c\udfa8 \u89c2\u611f\u989c\u503c<\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st\">\u2605<\/span><\/div><\/td><td><div class=\"stars\"><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><span class=\"st on\">\u2605<\/span><\/div><\/div><\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"note ng\" style=\"margin-top:12px\">\ud83d\udcca \u4e24\u65b9\u6848\u5728\u524d\u56db\u4e2a\u7ef4\u5ea6\uff08\u6362\u6c14\u3001\u51c0\u5316\u3001\u9759\u97f3\u3001\u8282\u80fd\uff09<strong>\u5b8c\u5168\u76f8\u540c<\/strong>\u2014\u2014\u56e0\u4e3a\u4f7f\u7528\u76f8\u540c\u7684\u98ce\u91cf\u3001\u7535\u673a\u3001\u70ed\u4ea4\u6362\u82af\u4f53\u3002\u5dee\u5f02\u4ec5\u5728\u667a\u80fd\u64cd\u63a7\uff08\u5929\u51c0\u5c4f\u5e55\u66f4\u5927\u66f4\u76f4\u89c2\uff09\u548c\u89c2\u611f\u989c\u503c\uff08\u5929\u51c0\u5916\u89c2\u66f4\u7cbe\u81f4\uff09\u4e24\u4e2a\u7ef4\u5ea6\u4e0a\u3002<\/div>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u4e5d\u3001\u8d39\u7528\u516d\u7ef4\u5ea6 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"cost-compare\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u4e5d<\/span><\/div>\n  <h2 class=\"sec-title\">\u4e5d\u3001\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n\n  <div class=\"card edge-o\">\n    <table class=\"tbl\"><thead><tr><th>\u8d39\u7528\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00\u00b7\u4e91\u51c0II<\/th><th>\u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5<\/th><th>\u6700\u4f18<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u521d\u6295\u8d44<\/td><td class=\"hi pr\">11,500<\/td><td class=\"pr\">14,600<\/td><td class=\"hi\">\u65b9\u6848\u4e00<\/td><\/tr>\n      <tr><td>\u5e74\u5747\u7535\u8d39<\/td><td class=\"pr\">\u7ea6180~300\u5143<\/td><td class=\"pr\">\u7ea6180~300\u5143<\/td><td>\u6301\u5e73<\/td><\/tr>\n      <tr><td>\u6ee4\u82af\u8d39\u7528<\/td><td class=\"pr\">0\u5143\/10\u5e74\uff08\u514d\u66f4\u6362\uff09<\/td><td class=\"pr\">0\u5143\/10\u5e74\uff08\u514d\u66f4\u6362\uff09<\/td><td>\u6301\u5e73<\/td><\/tr>\n      <tr><td>\u7ef4\u62a4\u6210\u672c<\/td><td class=\"pr\">\u6781\u4f4e<\/td><td class=\"pr\">\u6781\u4f4e<\/td><td>\u6301\u5e73<\/td><\/tr>\n      <tr><td>10\u5e74\u603b\u6295\u5165<\/td><td class=\"pr\">\u7ea613,300~14,500\u5143<\/td><td class=\"pr\">\u7ea616,400~17,600\u5143<\/td><td>\u65b9\u6848\u4e00\u7565\u4f18<\/td><\/tr>\n      <tr><td>\u6027\u4ef7\u6bd4\u6307\u6570<\/td><td class=\"hi\">\u2605\u2605\u2605\u2605\u2605<\/td><td>\u2605\u2605\u2605\u2605\u2606<\/td><td class=\"hi\">\u65b9\u6848\u4e00<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"note no\" style=\"margin-top:12px\">\ud83d\udccc \u65b0\u98ce\u7cfb\u7edf\u7684\u8fd0\u884c\u6210\u672c\u5f88\u4f4e\u2014\u2014\u6700\u5927\u529f\u7387162W\uff0c\u5373\u4f7f\u5168\u5929\u5f00\u542f\uff0c\u65e5\u5747\u8017\u7535\u91cf\u4e0d\u52302\u5ea6\uff0c\u6708\u5747\u7535\u8d39\u7ea615-25\u5143\u3002<strong>\u4e24\u65b9\u6848\u8fd0\u884c\u6210\u672c\u5b8c\u5168\u4e00\u81f4<\/strong>\uff08\u540c\u529f\u7387\uff09\uff0c\u552f\u4e00\u5dee\u5f02\u5c31\u662f\u521d\u6295\u8d44\u76843,100\u5143\u3002<\/div>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u5341\u3001\u9009\u578b\u5efa\u8bae ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"recommend\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u5341<\/span><\/div>\n  <h2 class=\"sec-title\">\u5341\u3001\u9009\u578b\u5efa\u8bae<\/h2>\n\n  <div class=\"card edge-g\">\n    <table class=\"tbl\"><thead><tr><th>\u573a\u666f<\/th><th>\u63a8\u8350\u65b9\u6848<\/th><th>\u7406\u7531<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u9884\u7b97\u4f18\u5148<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e00\u00b7\u4e91\u51c0II<\/td><td>11,500\u5143\uff0c\u4e24\u65b9\u6848\u6700\u4f4e<\/td><\/tr>\n      <tr><td>\u4f53\u9a8c\u4f18\u5148<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5<\/td><td>14,600\u5143\uff0c\u5c4f\u5e55+\u8054\u52a8+\u989c\u503c\u5168\u9762\u63d0\u5347<\/td><\/tr>\n      <tr><td>\u5df2\u6709\/\u8ba1\u5212\u88c5\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5<\/td><td>\u652f\u6301\u4e0e\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u80fd\u8054\u52a8\uff0c\u4e00\u4f53\u5316\u63a7\u5236\u4f53\u9a8c<\/td><\/tr>\n      <tr><td>\u5173\u6ce8\u7a7a\u6c14\u8d28\u91cf\u53ef\u89c6\u5316<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5<\/td><td>\u8d85\u5927\u5c4f\u5b9e\u65f6\u663e\u793aCO\u2082\/PM2.5\/\u6e29\u6e7f\u5ea6\u6570\u636e<\/td><\/tr>\n      <tr><td>\u7b80\u5355\u591f\u7528\u5c31\u597d<\/td><td class=\"hi\">\u2705 \u65b9\u6848\u4e00\u00b7\u4e91\u51c0II<\/td><td>\u6362\u6c14\u3001\u51c0\u5316\u3001\u70ed\u4ea4\u6362\u6027\u80fd\u4e0e\u5929\u51c0\u4e00\u81f4\uff0c\u5c11\u82b1\u94b1\u529e\u540c\u6837\u7684\u4e8b<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card edge-o\" style=\"margin-top:16px;\">\n    <div class=\"card-head\"><div class=\"card-icon co\">\ud83c\udfaf<\/div><div><div class=\"card-title\">\u7efc\u5408\u63a8\u8350<\/div><\/div><\/div>\n    <p><strong>\u65b9\u6848\u4e00\uff08\u4e91\u51c0II 250\uff09\u603b\u4ef7\u7ea611,500\u5143<\/strong>\uff0c\u4e24\u65b9\u6848\u4e2d\u521d\u6295\u8d44\u6700\u4f4e\u3002\u98ce\u91cf250m\u00b3\/h\u5145\u5206\u8986\u76d6\u674e\u5148\u751f\u5bb6190m\u00b3\/h\u7684\u9700\u6c42\uff0c\u5168\u70ed\u4ea4\u6362\u6548\u738780%\u3001HEPA\u8fc7\u6ee4\u226598%\u3001\u6700\u4f4e\u566a\u97f323.5dB\uff0c\u6838\u5fc3\u6027\u80fd\u4e0e\u5929\u51c0\u5b8c\u5168\u4e00\u81f4\u3002\u9002\u5408\u9884\u7b97\u654f\u611f\u3001\u8ffd\u6c42\u5b9e\u7528\u7684\u5ba2\u6237\u3002<\/p>\n    <br>\n    <p><strong>\u65b9\u6848\u4e8c\uff08\u5929\u51c0Q5 250\uff09\u603b\u4ef7\u7ea614,600\u5143<\/strong>\uff0c\u6bd4\u65b9\u6848\u4e00\u8d35\u7ea63,100\u5143\u3002\u591a\u82b1\u7684\u94b1\u6362\u6765\uff1a\u8d85\u5927\u5c4f\u7a7a\u6c14\u53ef\u89c6\u5316\uff08\u5b9e\u65f6\u770b\u5230\u5bb6\u91ccCO\u2082\/PM2.5\u6570\u503c\uff09\u3001\u4e0e\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7684\u667a\u80fd\u8054\u52a8\u80fd\u529b\u3001\u66f4\u7cbe\u81f4\u7684\u5de5\u4e1a\u8bbe\u8ba1\u548c\u54c1\u724c\u5b9a\u4f4d\u3002\u5982\u679c\u9884\u7b97\u5141\u8bb8\uff0c\u6216\u5df2\u88c5\/\u8ba1\u5212\u88c5\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff0c<strong>\u5f3a\u70c8\u63a8\u8350\u65b9\u6848\u4e8c<\/strong>\u3002<\/p>\n    <br>\n    <p class=\"hi\" style=\"font-size:1.05rem;\">\ud83d\udca1 \u6700\u7ec8\u5efa\u8bae\uff1a<strong>\u5982\u679c\u674e\u5148\u751f\u5bb6\u540c\u65f6\u914d\u7f6e\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff0c\u5efa\u8bae\u4e00\u6b65\u5230\u4f4d\u9009\u5929\u51c0Q5\uff08\u65b9\u6848\u4e8c\uff09\uff1b\u5982\u679c\u5355\u72ec\u914d\u65b0\u98ce\u4e14\u9884\u7b97\u6709\u9650\uff0c\u4e91\u51c0II\uff08\u65b9\u6848\u4e00\uff09\u5b8c\u5168\u591f\u7528\u3002<\/strong><\/p>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u5341\u4e00\u3001\u670d\u52a1\u4fdd\u969c ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"service\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u5341\u4e00<\/span><\/div>\n  <h2 class=\"sec-title\">\u5341\u4e00\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u4fdd\u969c<\/h2>\n\n  <div class=\"card edge-b\"><div class=\"steps\">\n    <div class=\"step done\"><div class=\"dot\"><\/div><div class=\"st\">01 \u73b0\u573a\u52d8\u6d4b<\/div><div class=\"sd\">\u8bbe\u8ba1\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u4e3b\u673a\u4f4d\u7f6e\u3001\u7ba1\u8def\u8d70\u5411\u3001\u9001\u6392\u98ce\u53e3\u4f4d\u7f6e\uff0c\u7cbe\u786e\u6d4b\u91cf\u7ba1\u8def\u957f\u5ea6<\/div><\/div>\n    <div class=\"step\"><div class=\"dot\"><\/div><div class=\"st\">02 \u7cfb\u7edf\u8bbe\u8ba1<\/div><div class=\"sd\">\u7ed8\u5236\u7ba1\u8def\u5e03\u7f6e\u56fe\u3001\u98ce\u53e3\u4f4d\u7f6e\u56fe\uff0c\u7ecf\u5ba2\u6237\u786e\u8ba4\u540e\u4f5c\u4e3a\u65bd\u5de5\u4f9d\u636e<\/div><\/div>\n    <div class=\"step\"><div class=\"dot\"><\/div><div class=\"st\">03 \u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/div><div class=\"sd\">\u65b0\u98ce\u4e3b\u673a\u6838\u5bf9\u578b\u53f7\u5e8f\u5217\u53f7\uff0c\u7ba1\u6750\/\u98ce\u53e3\/\u914d\u4ef6\u5171\u540c\u9a8c\u6536\u786e\u8ba4<\/div><\/div>\n    <div class=\"step\"><div class=\"dot\"><\/div><div class=\"st\">04 \u7ba1\u9053\u5b89\u88c5<\/div><div class=\"sd\">PVC\u98ce\u7ba1\u94fa\u8bbe\u3001\u98ce\u53e3\u5b89\u88c5\u3001\u7a7f\u5899\u6253\u5b54\uff08\u5916\u5899\u8fdb\u98ce\/\u6392\u98ce\uff09\u3001\u5bc6\u5c01\u5904\u7406<\/div><\/div>\n    <div class=\"step\"><div class=\"dot\"><\/div><div class=\"st\">05 \u4e3b\u673a\u5b89\u88c5+\u8c03\u8bd5<\/div><div class=\"sd\">\u4e3b\u673a\u540a\u88c5\u5c31\u4f4d\u3001\u7ba1\u8def\u8fde\u63a5\u3001\u7535\u6c14\u63a5\u7ebf\u3001\u8fd0\u884c\u8c03\u8bd5\u3001\u98ce\u901f\/\u98ce\u91cf\u6807\u5b9a<\/div><\/div>\n    <div class=\"step\"><div class=\"dot\"><\/div><div class=\"st\">06 \u7ae3\u5de5\u4ea4\u4ed8<\/div><div class=\"sd\">\u9690\u853d\u5de5\u7a0b\u5f71\u50cf\u5f52\u6863\u3001\u64cd\u4f5c\u6559\u5b66\u3001\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u4ea4\u4ed8<\/div><\/div>\n  <\/div><\/div>\n\n  <div class=\"card edge-o\" style=\"margin-top:16px;\">\n    <div class=\"card-head\"><div class=\"card-icon co\">\ud83d\udee1\ufe0f<\/div><div><div class=\"card-title\">\u8d28\u4fdd\u4e0e\u670d\u52a1\u627f\u8bfa<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>\u4fdd\u969c\u5185\u5bb9<\/th><th>\u4fdd\u969c\u671f\u9650<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody>\n      <tr><td>\u65e5\u7acb\u4e3b\u673a\u8d28\u4fdd<\/td><td class=\"hi\">\u6574\u673a3\u5e74 \/ \u6838\u5fc3\u90e8\u4ef65\u5e74<\/td><td>\u5382\u5bb6\u5b98\u65b9\u8d28\u4fdd<\/td><\/tr>\n      <tr><td>\u9f99\u8109\u5de5\u7a0b\u5b89\u88c5\u8d28\u4fdd<\/td><td class=\"hi\">5\u5e74\u8d77<\/td><td>\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u514d\u8d39\u4fee\u590d<\/td><\/tr>\n      <tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u6c38\u4e45<\/td><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u65b9\u6848\u54a8\u8be2\u3001\u80fd\u8017\u8ddf\u8e2a<\/td><\/tr>\n      <tr><td>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/td><td>10\u5e74<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u540e\u4e3b\u52a8\u56de\u8bbf\uff0c\u5f02\u5e38\u80fd\u8017\u514d\u8d39\u8bca\u65ad<\/td><\/tr>\n      <tr><td>\u6ee4\u82af\u670d\u52a1<\/td><td>10\u5e74\u514d\u6362<\/td><td>\u65e5\u7acb\u65b0\u98ce\u6ee4\u82af10\u5e74\u5185\u65e0\u9700\u66f4\u6362<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u5341\u4e8c\u3001AI\u9a8c\u8bc1 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"ai-verify\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u5341\u4e8c<\/span><\/div>\n  <h2 class=\"sec-title\">\u5341\u4e8c\u3001AI\u9a8c\u8bc1\u6307\u5f15\u4e0e\u9644\u6ce8\u6761\u6b3e<\/h2>\n\n  <div class=\"card edge-b\">\n    <div class=\"card-head\"><div class=\"card-icon cb\">\ud83e\udd16<\/div><div><div class=\"card-title\">AI\u81ea\u68c0\u95ee\u9898<\/div><div class=\"card-sub\">\u4ee5\u4e0b\u95ee\u9898\u7531AI\u81ea\u52a8\u68c0\u67e5\uff0c\u786e\u4fdd\u65b9\u6848\u5408\u89c4\u53ef\u9760<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>#<\/th><th>AI\u81ea\u68c0\u95ee\u9898<\/th><th>\u72b6\u6001<\/th><\/tr><\/thead><tbody>\n      <tr><td>1<\/td><td>\u65b0\u98ce\u91cf\u662f\u5426\u6ee1\u8db3JGJ\/T440-2018\u6807\u51c6\u8981\u6c42\uff1f<\/td><td><span class=\"tag tg\">\u2705 \u901a\u8fc7<\/span> \u9700\u6c42190m\u00b3\/h\uff0c\u4e3b\u673a250m\u00b3\/h\uff0c\u5f97\u98ce\u73870.8\u00d7\u5b89\u5168\u7cfb\u65701.1\u540e\u4f59\u91cf\u5145\u8db3<\/td><\/tr>\n      <tr><td>2<\/td><td>\u6362\u6c14\u6b21\u6570\u662f\u5426\u8fbe\u6807\uff1f<\/td><td><span class=\"tag tg\">\u2705 \u901a\u8fc7<\/span> \u4eba\u5747\u5c45\u4f4f\u9762\u79ef\uff1e10\u33a1\uff0c\u53d60.7\u6b21\/h\u6362\u6c14\uff0c\u6ee1\u8db3\u6807\u51c6<\/td><\/tr>\n      <tr><td>3<\/td><td>\u673a\u5916\u9759\u538b\u662f\u5426\u6ee1\u8db3\u7ba1\u8def\u963b\u529b\uff1f<\/td><td><span class=\"tag tg\">\u2705 \u901a\u8fc7<\/span> \u6700\u5927\u9759\u538b80Pa\uff0c6\u8defDe50\u652f\u7ba1+De75\u4e3b\u7ba1\uff0c\u963b\u529b\u4f30\u7b97\u7ea640-60Pa<\/td><\/tr>\n      <tr><td>4<\/td><td>\u566a\u97f3\u662f\u5426\u6ee1\u8db3\u5367\u5ba4\u7761\u7720\u8981\u6c42\uff1f<\/td><td><span class=\"tag tg\">\u2705 \u901a\u8fc7<\/span> \u4f4e\u901f\u686323.5dB\uff0c\u8fdc\u4f4e\u4e8e\u5367\u5ba4\u80cc\u666f\u566a\u97f330dB\u6807\u51c6<\/td><\/tr>\n      <tr><td>5<\/td><td>\u5168\u70ed\u4ea4\u6362\u662f\u5426\u9002\u914d\u6210\u90fd\u6c14\u5019\uff1f<\/td><td><span class=\"tag tg\">\u2705 \u901a\u8fc7<\/span> \u6210\u90fd\u51ac\u5b63\u6e7f\u5ea6\u5927\uff0c\u5168\u70ed\u4ea4\u6362\u56de\u6536\u6e29\u6e7f\u5ea6\uff0c\u907f\u514d\u5e72\u71e5<\/td><\/tr>\n      <tr><td>6<\/td><td>\u6ee4\u82af\u5bff\u547d\u662f\u5426\u7ecf\u6d4e\u5408\u7406\uff1f<\/td><td><span class=\"tag tg\">\u2705 \u901a\u8fc7<\/span> \u65e5\u7acb\u65b0\u98ce\u6ee4\u82af10\u5e74\u514d\u66f4\u6362\uff0c\u957f\u671f\u4f7f\u7528\u6210\u672c\u4f4e<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"card edge-o\" style=\"margin-top:16px;\">\n    <div class=\"card-head\"><div class=\"card-icon co\">\ud83d\udccb<\/div><div><div class=\"card-title\">\u6e29\u99a8\u63d0\u793a<\/div><\/div><\/div>\n    <table class=\"tbl\"><thead><tr><th>#<\/th><th>\u63d0\u793a\u5185\u5bb9<\/th><\/tr><\/thead><tbody>\n      <tr><td>1<\/td><td>\u672c\u65b9\u6848\u65b0\u98ce\u9762\u79ef\u4e3a100.4\u33a1\uff0c\u6309\u65e5\u7acb250\u98ce\u91cf\u65b0\u98ce\u673a\uff08\u4e91\u51c0\/\u5929\u51c0\u4e24\u6863\uff09\u62a5\u4ef7<\/td><\/tr>\n      <tr><td>2<\/td><td>\u4ee5\u4e0a\u4ef7\u683c\u4e3a\u542b\u7a0e\u542b\u5b89\u88c5\u7684\u5b8c\u6574\u843d\u5730\u4ef7\u683c\uff0c\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr>\n      <tr><td>3<\/td><td>\u5b9e\u9645\u65bd\u5de5\u4e2d\u4ee5\u73b0\u573a\u5b9e\u6d4b\u7ba1\u8def\u957f\u5ea6\u4e3a\u51c6\uff0c\u8bef\u5dee\u00b15%\u4ee5\u5185\u4e0d\u8c03\u4ef7<\/td><\/tr>\n      <tr><td>4<\/td><td>\u65b0\u98ce\u4e3b\u673a\u4e3a\u65e5\u7acb\u539f\u88c5\u6b63\u54c1\uff0c\u4eab\u53d7\u5382\u5bb6\u5b98\u65b9\u8d28\u4fdd\uff08\u6574\u673a3\u5e74\/\u6838\u5fc3\u90e8\u4ef65\u5e74\uff09<\/td><\/tr>\n      <tr><td>5<\/td><td>\u5982\u9700\u8054\u52a8\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff0c\u8bf7\u9009\u7528\u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5\u7cfb\u5217<\/td><\/tr>\n      <tr><td>6<\/td><td>\u5916\u5899\u6253\u5b54\u9700\u786e\u8ba4\u7269\u4e1a\u89c4\u5b9a\uff0c\u90e8\u5206\u5c0f\u533a\u9700\u7269\u4e1a\u5ba1\u6279<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ \u5341\u4e09\u3001\u4e0b\u4e00\u6b65\u884c\u52a8 ============ -->\n<div class=\"wrap\"><div class=\"sec\" id=\"next\">\n  <div class=\"sec-label\"><span class=\"geo-num\">\u5341\u4e09<\/span><\/div>\n  <h2 class=\"sec-title\">\u5341\u4e09\u3001\u4e0b\u4e00\u6b65\u884c\u52a8<\/h2>\n\n  <div class=\"card edge-o\">\n    <table class=\"tbl\"><thead><tr><th>\u4f18\u5148\u7ea7<\/th><th>\u52a8\u4f5c<\/th><th>\u8d1f\u8d23\u4eba<\/th><\/tr><\/thead><tbody>\n      <tr><td><span class=\"tag to\">P0<\/span><\/td><td>\u5728\u4e24\u79cd\u65b9\u6848\u4e2d\u505a\u51fa\u6700\u7ec8\u9009\u62e9\uff08\u4e91\u51c0 vs \u5929\u51c0\uff09<\/td><td>\u674e\u5148\u751f<\/td><\/tr>\n      <tr><td><span class=\"tag tb\">P1<\/span><\/td><td>\u9009\u5b9a\u65b9\u6848\u540e\uff0c\u5b89\u6392\u73b0\u573a\u52d8\u6d4b\u786e\u5b9a\u6700\u7ec8\u7ba1\u8def\u8d70\u5411<\/td><td>\u53cc\u65b9<\/td><\/tr>\n      <tr><td><span class=\"tag tb\">P1<\/span><\/td><td>\u786e\u8ba4\u4e3b\u673a\u5b89\u88c5\u4f4d\u7f6e\uff08\u901a\u5e38\u5728\u9633\u53f0\u6216\u8bbe\u5907\u95f4\uff09<\/td><td>\u53cc\u65b9<\/td><\/tr>\n      <tr><td><span class=\"tag tg\">P2<\/span><\/td><td>\u7b7e\u8ba2\u6b63\u5f0f\u5408\u540c\uff0c\u9501\u5b9a\u4f18\u60e0\uff0c\u5b89\u6392\u65bd\u5de5\u6392\u671f<\/td><td>\u53cc\u65b9<\/td><\/tr>\n      <tr><td><span class=\"tag tg\">P2<\/span><\/td><td>\u65bd\u5de5\u5b8c\u6210\u540e\u73b0\u573a\u9a8c\u6536+\u64cd\u4f5c\u6559\u5b66\u57f9\u8bad<\/td><td>\u9f99\u8109\u6696\u901a+\u674e\u5148\u751f<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n<\/div><\/div>\n\n<!-- ============ FOOTER ============ -->\n<footer class=\"wrap\"><div class=\"foot\">\n  <p class=\"fm\">\ud83c\udf00 \u4e0d\u5f00\u7a97\u4e5f\u80fd\u547c\u5438\u65b0\u9c9c\u7a7a\u6c14\u2014\u2014\u65e5\u7acb\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/p>\n  <p>\u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a\u00b7\u9ec4\u52c7 \ud83d\udcde 15828489188 | \u9f99\u8109\u6696\u901a\u00b7\u59cb\u4e8e2004 | \u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf22\u5e74<\/p>\n  <p style=\"margin-top:4px;\">\u4e24\u65b9\u6848\u603b\u4ef7\uff1a\u65b9\u6848\u4e00\u00b7\u4e91\u51c0II 11,500\u5143 \u00b7 \u65b9\u6848\u4e8c\u00b7\u5929\u51c0Q5 14,600\u5143\uff08\u5747\u4e3a\u542b\u5b89\u88c5\u8c03\u8bd5\u5b8c\u6574\u843d\u5730\u4ef7\uff09<\/p>\n  <p style=\"margin-top:10px;font-size:.72rem;\">\u00a9 \u9f99\u8109\u6696\u901a 2004-2026 | \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 | <a href=\"https:\/\/longmai-nt.com\/?page_id=3011\" target=\"_blank\" style=\"color:var(--blue);\">\u5b98\u7f51\u7ad9\u70b9\u5730\u56fe<\/a> | <a href=\"https:\/\/longmai-nt.com\/?page_id=4988\" target=\"_blank\" style=\"color:var(--blue);\">\u65b0\u98ce\u65b9\u6848\u6a21\u677f\u53c2\u8003<\/a><\/p>\n<\/div><\/footer>\n\n<!-- ============ SCRIPTS ============ -->\n<script>\n\/\/ ============ Price Tab Switching (uses slider) ============\nfunction showPriceTab(e, idx) {\n  e.preventDefault();\n  var card = e.target.closest('.card');\n  if (!card) card = document.getElementById('pricing');\n  var tabs = card.querySelectorAll('.comp-tabs .comp-tab');\n  tabs.forEach(function(t, i) { t.classList.toggle('active', i === idx); });\n  var track = document.getElementById('priceTrack');\n  if (track) track.style.transform = 'translateX(-' + (idx * 100) + '%)';\n}\n\n\/\/ ============ GEO Nav Active State ============\n(function() {\n  var navLinks = document.querySelectorAll('.geo-nav a');\n  var sections = [];\n  navLinks.forEach(function(a) {\n    var href = a.getAttribute('href');\n    if (href && href.startsWith('#')) {\n      var el = document.querySelector(href);\n      if (el) sections.push({ link: a, el: el });\n    }\n  });\n  function updateActive() {\n    var scrollY = window.scrollY + 100;\n    var active = null;\n    sections.forEach(function(s) {\n      if (s.el.offsetTop <= scrollY) active = s.link;\n    });\n    navLinks.forEach(function(a) { a.classList.remove('active'); });\n    if (active) active.classList.add('active');\n  }\n  window.addEventListener('scroll', updateActive, { passive: true });\n  updateActive();\n})();\n\n\/\/ ============ Touch swipe support for price slider ============\n(function() {\n  var slider = document.getElementById('priceSlider');\n  if (!slider) return;\n  var startX = 0, moved = false;\n  slider.addEventListener('touchstart', function(e) { startX = e.touches[0].clientX; moved = false; }, { passive: true });\n  slider.addEventListener('touchend', function(e) {\n    if (!moved) return;\n    var diff = startX - e.changedTouches[0].clientX;\n    if (Math.abs(diff) > 50) {\n      var track = document.getElementById('priceTrack');\n      var current = parseInt(track.style.transform.replace('translateX(-', '').replace('%)', '')) || 0;\n      var next = current + (diff > 0 ? 100 : -100);\n      next = Math.max(0, Math.min(100, next));\n      track.style.transform = 'translateX(-' + next + '%)';\n      var idx = next \/ 100;\n      var tabs = document.querySelectorAll('#priceCompTabs .comp-tab');\n      tabs.forEach(function(t, i) { t.classList.toggle('active', i === idx); });\n    }\n  });\n  slider.addEventListener('touchmove', function() { moved = true; }, { passive: true });\n})();\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\ud83c\udf00 \u9f99\u8109\u6696\u901a \u65e5\u7acb\u65b0\u98ce \u00b7 \u65b9\u6848\u5bf9\u6bd4\u4e66  [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-5476","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=5476\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\ud83c\udf00 \u9f99\u8109\u6696\u901a \u65e5\u7acb\u65b0\u98ce \u00b7 \u65b9\u6848\u5bf9\u6bd4\u4e66 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=5476\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5476\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5476\",\"name\":\"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-07-05T04:31:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5476#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5476\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5476#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=5476","og_locale":"zh_CN","og_type":"article","og_title":"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\ud83c\udf00 \u9f99\u8109\u6696\u901a \u65e5\u7acb\u65b0\u98ce \u00b7 \u65b9\u6848\u5bf9\u6bd4\u4e66 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=5476","og_site_name":"\u9f99\u8109\u6696\u901a","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=5476","url":"https:\/\/longmai-nt.com\/?page_id=5476","name":"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-07-05T04:31:06+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=5476#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=5476"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=5476#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u674e\u5148\u751f \u00b7 \u65b0\u98ce\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5476"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5476\/revisions"}],"predecessor-version":[{"id":5480,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5476\/revisions\/5480"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}