{"id":5609,"date":"2026-07-07T14:02:25","date_gmt":"2026-07-07T06:02:25","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=5609"},"modified":"2026-07-07T14:07:07","modified_gmt":"2026-07-07T06:07:07","slug":"%e9%99%88%e8%80%81%e5%b8%88-%c2%b7-%e9%be%99%e6%b9%96%e4%b8%89%e5%8d%83%e4%ba%91%e9%94%a6%e5%b0%8a%e7%91%9e%e5%85%a8%e6%95%88%e5%a4%9a%e6%96%b9%e6%a1%88%e5%af%b9%e6%af%94%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=5609","title":{"rendered":"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66"},"content":{"rendered":"\n\n<style>\n:root{--orange:#E8652D;--blue:#1a5276;--green:#27ae60;--gold:#f39c12;--bg:#f8f9fa;--card-bg:#fff;--text:#2c3e50;--text-light:#666;--border:#e0e0e0;--shadow:0 2px 12px rgba(0,0,0,0.08);--warn:#e74c3c;}\n*{margin:0;padding:0;box-sizing:border-box;}\nbody{font-family:-apple-system,'PingFang SC','Microsoft YaHei',sans-serif;background:var(--bg);color:var(--text);line-height:1.7;width:100%;overflow-x:hidden;}\n.topbar{background:linear-gradient(135deg,#1a2a3a,#1a5276);color:#fff;padding:12px 0;position:sticky;top:0;z-index:100;}\n.topbar .wrap{width:100%;max-width:1400px;margin:0 auto;padding:0 20px;display:flex;align-items:center;justify-content:space-between;flex-wrap:wrap;gap:10px;}\n.topbar-logo{font-size:18px;font-weight:700;letter-spacing:1px;}\n.topbar-logo span{color:var(--orange);}\n.topbar-info{font-size:13px;opacity:0.85;}\n.topbar-badge{background:var(--orange);color:#fff;padding:3px 10px;border-radius:12px;font-size:12px;font-weight:600;}\n.hero{background:linear-gradient(135deg,#1a5276 0%,#1a2a3a 60%,#0d1b2a 100%);color:#fff;padding:50px 0 40px;text-align:center;}\n.hero .wrap{max-width:1400px;margin:0 auto;padding:0 20px;}\n.hero-chip{display:inline-block;background:rgba(255,255,255,0.12);border:1px solid rgba(255,255,255,0.25);padding:5px 16px;border-radius:20px;font-size:13px;margin-bottom:18px;}\n.hero h1{font-size:32px;font-weight:700;margin-bottom:12px;letter-spacing:1px;}\n.hero h1 span{color:var(--orange);}\n.hero .sub{font-size:16px;opacity:0.75;margin-bottom:30px;}\n.hero-meta{display:flex;justify-content:center;gap:40px;flex-wrap:wrap;font-size:14px;margin-bottom:28px;}\n.hero-meta-item{text-align:center;}\n.hero-meta-item .val{font-size:28px;font-weight:700;color:var(--orange);}\n.hero-meta-item .lbl{opacity:0.7;margin-top:2px;}\n.hero-cats{display:flex;justify-content:center;gap:6px;flex-wrap:wrap;max-width:900px;margin:0 auto;}\n.cat-btn{display:inline-flex;align-items:center;gap:5px;padding:10px 20px;font-size:14px;font-weight:700;color:rgba(255,255,255,0.85);cursor:pointer;border-radius:10px;border:2px solid rgba(255,255,255,0.25);background:rgba(255,255,255,0.08);white-space:nowrap;transition:all 0.25s ease;user-select:none;flex-shrink:0;}\n.cat-btn:hover{background:rgba(255,255,255,0.18);border-color:#e67e22;color:#fff;}\n.cat-btn.active{background:#e67e22;border-color:#e67e22;color:#fff;box-shadow:0 0 18px rgba(230,126,34,0.45);}\n.bc-bar{background:#fff;border-bottom:2px solid #e0e0e0;position:sticky;top:54px;z-index:98;padding:10px 0;}\n.bc-bar .wrap{max-width:1400px;margin:0 auto;padding:0 20px;}\n.bc-group{display:flex;align-items:center;gap:4px;flex-wrap:wrap;}\n.bc-group[hidden]{display:none;}\n.bc-link{font-size:13px;color:#555;cursor:pointer;padding:4px 10px;border-radius:6px;border:1px solid #ddd;background:#f8f8f8;transition:all 0.2s;}\n.bc-link:hover{color:var(--orange);background:#fff5ec;border-color:var(--orange);}\n.bc-link.active{color:#fff;background:var(--orange);border-color:var(--orange);}\n.bc-sep{color:#ccc;font-size:12px;}\n.sec{display:none;padding:50px 0;}\n.sec.active{display:block;}\n.wrap{max-width:1400px;margin:0 auto;padding:0 20px;}\n.sec-label{display:inline-block;background:var(--blue);color:#fff;padding:4px 14px;border-radius:20px;font-size:13px;font-weight:600;margin-bottom:12px;}\nh2.sec-title{font-size:26px;font-weight:700;color:var(--blue);margin-bottom:28px;}\n.card{background:var(--card-bg);border-radius:12px;padding:24px;margin-bottom:20px;box-shadow:var(--shadow);border-left:4px solid var(--orange);}\n.card.edge-b{border-left-color:var(--blue);}\n.card.edge-g{border-left-color:var(--green);}\n.card.edge-w{border-left-color:var(--warn);}\n.tbl{width:100%;border-collapse:collapse;margin:16px 0;font-size:13px;}\n.tbl th{background:var(--blue);color:#fff;padding:10px 8px;text-align:center;font-weight:600;}\n.tbl td{padding:9px 8px;text-align:center;border-bottom:1px solid #eee;}\n.tbl tr:hover td{background:#f5f8ff;}\n.tbl tr.total-row td{background:#fff8f0;font-weight:700;color:var(--orange);}\n.tbl-cmp th{background:var(--blue);color:#fff;padding:10px 8px;text-align:center;font-weight:600;font-size:13px;}\n.tbl-cmp td{padding:9px 8px;text-align:center;border-bottom:1px solid #eee;font-size:13px;}\n.tbl-cmp td:first-child{text-align:left;font-weight:600;background:#f8f9fa;}\n.tbl-cmp tr:hover td{background:#f5f8ff;}\n.note{padding:14px 18px;border-radius:10px;margin:16px 0;font-size:13px;line-height:1.7;}\n.note.no{background:#fff8f0;border-left:4px solid var(--orange);}\n.note.nb{background:#eef2ff;border-left:4px solid var(--blue);}\n.note.ng{background:#eafaf1;border-left:4px solid var(--green);}\n.note.nw{background:#fdf2f2;border-left:4px solid var(--warn);}\n.comp-tabs{display:flex;gap:6px;margin-bottom:20px;flex-wrap:wrap;}\n.comp-tab{padding:10px 20px;border-radius:8px;font-size:14px;font-weight:600;cursor:pointer;border:2px solid #ddd;background:#f8f8f8;color:#555;transition:all 0.2s;}\n.comp-tab.active{background:var(--orange);color:#fff;border-color:var(--orange);}\n.tab-pane{display:none;}\n.tab-pane.active{display:block;}\n.footer{background:#1a2a3a;color:rgba(255,255,255,0.7);padding:30px 0;text-align:center;font-size:13px;}\n.footer-motto{font-size:18px;font-weight:700;color:#fff;margin-bottom:8px;}\n.footer-price{font-size:22px;color:var(--orange);font-weight:700;margin:10px 0;}\n.footer-copy{opacity:0.5;margin-top:12px;}\n.arch-box{display:inline-block;border:2px solid var(--blue);border-radius:8px;padding:8px 16px;margin:4px;text-align:center;font-size:13px;background:#eef2ff;}\n.arch-box.orange{border-color:var(--orange);background:#fff5ec;}\n.arch-box.green{border-color:var(--green);background:#eafaf1;}\n.arch-arrow{display:inline-block;margin:4px;color:var(--text-light);font-size:18px;}\n.arch-group{display:flex;align-items:center;justify-content:center;flex-wrap:wrap;gap:4px;margin:8px 0;}\n.price-tag{font-size:26px;font-weight:800;color:var(--orange);}\n.price-tag.small{font-size:18px;}\n.price-orig{text-decoration:line-through;color:var(--text-light);font-size:14px;}\n.install-tbl td:first-child{text-align:left;font-weight:600;}\n.install-tbl td:last-child{text-align:right;}\n<\/style>\n\n<!-- Topbar -->\n<div class=\"topbar\">\n  <div class=\"wrap\">\n    <div class=\"topbar-logo\">\u9f99\u8109<span>\u6696\u901a<\/span><\/div>\n    <div class=\"topbar-info\">\u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 \ud83d\udcde 15828489188<\/div>\n    <div class=\"topbar-badge\">\u4e09\u65b9\u6848\u5bf9\u6bd4 \u00b7 \u4f18\u60e0\u7248<\/div>\n  <\/div>\n<\/div>\n\n<!-- Hero -->\n<div class=\"hero\">\n  <div class=\"wrap\">\n    <div class=\"hero-chip\">\u9f99\u8109\u6696\u901a \u00b7 \u4e24\u8054\u4f9b\u65b9\u6848\u4e66<\/div>\n    <h1>\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526<br><span>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e09\u65b9\u6848\u5bf9\u6bd4<\/span><\/h1>\n    <p class=\"sub\">\u8bbe\u59078\u6298\u4f18\u60e0 \u00b7 \u900f\u660e\u62a5\u4ef7 \u00b7 \u5b89\u88c5\u8d39\u7528\u660e\u7ec6<\/p>\n    <div class=\"hero-meta\">\n      <div class=\"hero-meta-item\"><div class=\"val\">3\u5c42\u8054\u6392<\/div><div class=\"lbl\">\u623f\u5c4b\u7c7b\u578b<\/div><\/div>\n      <div class=\"hero-meta-item\"><div class=\"val\">7\u5ba4<\/div><div class=\"lbl\">\u623f\u95f4\u6570\u91cf<\/div><\/div>\n      <div class=\"hero-meta-item\"><div class=\"val\">198\u33a1<\/div><div class=\"lbl\">\u7a7a\u8c03\u9762\u79ef<\/div><\/div>\n      <div class=\"hero-meta-item\"><div class=\"val\">16\u56de\u8def<\/div><div class=\"lbl\">\u5730\u6696\u56de\u8def<\/div><\/div>\n      <div class=\"hero-meta-item\"><div class=\"val\">3\u65b9\u6848<\/div><div class=\"lbl\">\u5bf9\u6bd4\u65b9\u6848<\/div><\/div>\n    <\/div>\n    <div class=\"hero-cats\">\n      <button class=\"cat-btn active\" onclick=\"switchCat(0)\">\ud83d\udccb \u9879\u76ee\u6982\u51b5<\/button>\n      <button class=\"cat-btn\" onclick=\"switchCat(1)\">\ud83d\udd0d \u8bca\u65ad\u5206\u6790<\/button>\n      <button class=\"cat-btn\" onclick=\"switchCat(2)\">\ud83d\udca1 \u89e3\u51b3\u65b9\u6848<\/button>\n      <button class=\"cat-btn\" onclick=\"switchCat(3)\">\ud83d\udcca \u6838\u5fc3\u5bf9\u6bd4<\/button>\n      <button class=\"cat-btn\" onclick=\"switchCat(4)\">\ud83d\udee0\ufe0f \u65bd\u5de5\u4ea4\u4ed8<\/button>\n      <button class=\"cat-btn\" onclick=\"switchCat(5)\">\u2705 \u4e0b\u4e00\u6b65<\/button>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- Breadcrumb -->\n<div class=\"bc-bar\" id=\"bcBar\">\n  <div class=\"wrap\">\n    <div class=\"bc-group\" id=\"bc-0\">\n      <span class=\"bc-link active\" onclick=\"showSection('sec-1')\">\u9879\u76ee\u6982\u51b5<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-2')\">\u9700\u6c42\u75db\u70b9<\/span>\n    <\/div>\n    <div class=\"bc-group\" id=\"bc-1\" hidden>\n      <span class=\"bc-link\" onclick=\"showSection('sec-2')\">\u663e\u6027\u9700\u6c42<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-3')\">\u65b9\u6848\u5bf9\u6bd4<\/span>\n    <\/div>\n    <div class=\"bc-group\" id=\"bc-2\" hidden>\n      <span class=\"bc-link\" onclick=\"showSection('sec-3')\">\u5efa\u8bae\u65b9\u6848<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-4')\">\u62a5\u4ef7\u6c47\u603b<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-5')\">\u9009\u578b\u5efa\u8bae<\/span>\n    <\/div>\n    <div class=\"bc-group\" id=\"bc-3\" hidden>\n      <span class=\"bc-link active\" onclick=\"showSection('sec-compare')\">\u6838\u5fc3\u5bf9\u6bd4<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-4')\">\u62a5\u4ef7\u6c47\u603b<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-5')\">\u9009\u578b\u5efa\u8bae<\/span>\n    <\/div>\n    <div class=\"bc-group\" id=\"bc-4\" hidden>\n      <span class=\"bc-link\" onclick=\"showSection('sec-6')\">\u5b89\u88c5\u4fdd\u969c<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-heat')\">\u5730\u6696\u914d\u7f6e<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-materials')\">\u8f85\u6750\u6e05\u5355<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-cases')\">\u5ba2\u6237\u6848\u4f8b<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-member')\">\u4f1a\u5458\u6743\u76ca<\/span>\n    <\/div>\n    <div class=\"bc-group\" id=\"bc-5\" hidden>\n      <span class=\"bc-link\" onclick=\"showSection('sec-7')\">\u4e0b\u4e00\u6b65\u884c\u52a8<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-brand')\">\u54c1\u724c\u4ecb\u7ecd<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-ai')\">AI\u9a8c\u8bc1<\/span>\n      <span class=\"bc-sep\">\u203a<\/span>\n      <span class=\"bc-link\" onclick=\"showSection('sec-terms')\">\u9644\u6ce8\u6761\u6b3e<\/span>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- ========== sec-1 \u9879\u76ee\u6982\u51b5 ========== -->\n<section class=\"sec active\" id=\"sec-1\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u9879\u76ee\u6982\u51b5<\/div>\n  <h2 class=\"sec-title\">\u9879\u76ee\u57fa\u672c\u4fe1\u606f<\/h2>\n  <div class=\"card\">\n    <table class=\"tbl\">\n      <tr><td style=\"width:120px;font-weight:600;\">\u9879\u76ee\u540d\u79f0<\/td><td>\u9f99\u6e56\u4e09\u5343\u4e91\u9526<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u5ba2\u6237\u59d3\u540d<\/td><td>\u9648\u8001\u5e08<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u65b9\u6848\u65e5\u671f<\/td><td>2026\u5e747\u67087\u65e5<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u623f\u5c4b\u7c7b\u578b<\/td><td>3\u5c42\u8054\u6392\u522b\u5885<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u7a7a\u8c03\u9762\u79ef<\/td><td>\u7ea6198\u33a1\uff087\u5ba4\uff09<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u5730\u6696\u9762\u79ef<\/td><td>\u7ea6221.9\u33a1\uff0816\u56de\u8def\uff09<\/td><\/tr>\n      <tr><td style=\"font-weight:600;\">\u5bf9\u6bd4\u65b9\u6848<\/td><td>\u8212\u4eab+\u5c0a\u777f\u5168\u6548 \uff0f VAM\u5c0a\u777f\u5168\u6548 30kW \uff0f VAM\u5c0a\u777f\u5168\u6548 33.5kW<\/td><\/tr>\n    <\/table>\n  <\/div>\n  <div class=\"note nb\">\ud83d\udccb \u672c\u65b9\u6848\u4e66\u8bbe\u5907\u6309\u65e5\u7acb\u9762\u4ef7<strong>8\u6298<\/strong>\u4f18\u60e0\u62a5\u4ef7\uff08\u4e0d\u542b\u7ebf\u63a7\u5668\uff09\uff0c\u5730\u6696\u6309\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\u8ba1\u7b97\uff0c\u5b89\u88c5\u8d39\u7528\u660e\u7ec6\u9010\u4e00\u5217\u660e\u3002<\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-2 \u9700\u6c42\u75db\u70b9 ========== -->\n<section class=\"sec\" id=\"sec-2\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u9700\u6c42\u75db\u70b9<\/div>\n  <h2 class=\"sec-title\">\u60a8\u7684\u6838\u5fc3\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n  <div class=\"note nb\">\u6839\u636e\u9648\u8001\u5e08\u7684\u6237\u578b\u914d\u7f6e\u9700\u6c42\uff08\u9f99\u6e56\u4e09\u5343\u4e91\u9526 3\u5c42\u8054\u6392\uff09\uff0c\u6211\u4eec\u8bc6\u522b\u51fa\u4ee5\u4e0b\u6838\u5fc3\u75db\u70b9\uff1a<\/div>\n  <div class=\"card edge-b\" style=\"margin-top:20px;\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\u75db\u70b9\u4e00\uff1a\u5927\u9762\u79ef\u8054\u6392\uff0c\u7a7a\u8c03\u5730\u6696\u540c\u65f6\u5f00\u591f\u7528\u5417\uff1f<\/h3>\n    <p>\u4e09\u5c42\u8054\u6392\u51717\u5ba4\uff0c\u7a7a\u8c03\u9762\u79ef\u8fd1200\u33a1\uff0c\u5730\u6696\u7ea6222\u33a1\u3002\u65b9\u6848\u4e00\u91c7\u752814kW+20kW\u53cc\u5916\u673a\uff08\u8212\u4eab+\u5c0a\u777f\uff09\uff0c220V\u5373\u53ef\u9a71\u52a8\uff1b\u65b9\u6848\u4e8c30kW\u3001\u65b9\u6848\u4e0933.5kW\u5916\u673a\u5197\u4f59\u66f4\u5145\u8db3\uff0c\u5168\u5f00\u65f6\u80fd\u529b\u6709\u4fdd\u969c\u3002<\/p>\n  <\/div>\n  <div class=\"card\">\n    <h3 style=\"color:var(--orange);margin-bottom:12px;\">\u75db\u70b9\u4e8c\uff1a380V\u8981\u4e0d\u8981\u7533\u8bf7\uff1f\u6ca1\u6709380V\u600e\u4e48\u529e\uff1f<\/h3>\n    <p>\u65b9\u6848\u4e00\u91c7\u7528220V\u5355\u76f8\u7535\uff0c\u65e0\u9700\u7533\u8bf7380V\uff0c\u9002\u5408\u6682\u65e0380V\u6761\u4ef6\u7684\u5bb6\u5ead\u3002\u65b9\u6848\u4e8c\/\u4e09\u9700380V\u4e09\u76f8\u7535\uff0c\u5236\u51b7\/\u5236\u70ed\u80fd\u529b\u66f4\u5f3a\uff0c\u957f\u671f\u8fd0\u884c\u66f4\u8282\u80fd\u3002<\/p>\n  <\/div>\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:12px;\">\u75db\u70b9\u4e09\uff1a\u5730\u6696\u6c34\u6e29\u591f\u5417\uff1f\u80fd\u8017\u9ad8\u5417\uff1f<\/h3>\n    <p>\u4e09\u65b9\u6848\u5747\u914d\u7f6e\u8865\u6c14\u589e\u7113\u6c34\u6a21\u5757\uff0c\uff0d25\u2103\u8d85\u4f4e\u6e29\u6b63\u5e38\u5236\u70ed\uff0c\u51fa\u6c34\u6e29\u5ea6\u66f4\u9ad8\uff0c\u5730\u6696\u5347\u6e29\u66f4\u5feb\u3001\u66f4\u8282\u80fd\u3002<\/p>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-3 \u4e09\u65b9\u6848\u6a2a\u5411\u5bf9\u6bd4 ========== -->\n<section class=\"sec\" id=\"sec-3\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u5efa\u8bae\u65b9\u6848<\/div>\n  <h2 class=\"sec-title\">\u4e09\u65b9\u6848\u914d\u7f6e\u8be6\u60c5<\/h2>\n  <div class=\"note nb\">\u672c\u6b21\u63d0\u4f9b\u4e09\u5957\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u7cfb\u7edf\u914d\u7f6e\u65b9\u6848\u3002\u8bbe\u5907\u9762\u4ef7<strong>8\u6298<\/strong>\u4f18\u60e0\uff0c\u5730\u6696\u6309\u00a5169\/\u33a1\u4f18\u60e0\u62a5\u4ef7\u3002\ud83d\udc49 \u5982\u9700\u65b9\u6848\u6a2a\u5411\u5bf9\u6bd4\uff0c\u8bf7\u70b9\u51fb\u9876\u90e8\"\ud83d\udcca \u6838\u5fc3\u5bf9\u6bd4\"\u3002<\/div>\n  <div class=\"comp-tabs\">\n    <div class=\"comp-tab active\" onclick=\"switchTab('tab-1',this)\">\u65b9\u6848\u4e00 \u00b7 \u8212\u4eab+\u5c0a\u777f\u5168\u6548<\/div>\n    <div class=\"comp-tab\" onclick=\"switchTab('tab-2',this)\">\u65b9\u6848\u4e8c \u00b7 VAM\u5c0a\u777f\u5168\u6548 30kW<\/div>\n    <div class=\"comp-tab\" onclick=\"switchTab('tab-3',this)\">\u65b9\u6848\u4e09 \u00b7 VAM\u5c0a\u777f\u5168\u6548 33.5kW<\/div>\n  <\/div>\n  <div id=\"scheme-panes\">\n\n    <!-- ========== \u65b9\u6848\u4e00 ========== -->\n    <div class=\"tab-pane active\" id=\"tab-1\">\n      <h3 style=\"color:var(--blue);margin:20px 0 12px;\">\u65b9\u6848\u4e00 \u00b7 \u8212\u4eab+\u5c0a\u777f\u5168\u6548\uff08220V \u53cc\u5916\u673a\uff09<\/h3>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u5ba4\u5916\u673a\u2460 \u00b7 \u8212\u4eab\u5916\u673a\uff08\u9a71\u52a8\u7cfb\u7edf\u4e00 \u00b7 3\u53f0\u5185\u673a\uff09<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--blue);\">RAS-140HRNAQ<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u91cf<\/td><td>14000 W<\/td><td>\u5236\u70ed\u91cf<\/td><td>16000 W<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u8fd0\u8f6c\u8303\u56f4<\/td><td>-5~59 \u2103<\/td><td>\u5236\u70ed\u8fd0\u8f6c\u8303\u56f4<\/td><td>-21~17 \u2103<\/td><\/tr>\n        <tr><td>APF<\/td><td>5.8<\/td><td>\u566a\u97f3\u503c<\/td><td>54 dB(A)<\/td><\/tr>\n        <tr><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>770\u00d7980\u00d7360 mm<\/td><td>\u8fde\u63a5\u7387<\/td><td>114.3%<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a<\/td><td>\u53d8\u9891\u53cc\u8f6c\u5b50\u5f0f<\/td><td>\u7535\u6e90<\/td><td>220V~50Hz<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u5ba4\u5916\u673a\u2461 \u00b7 \u5c0a\u777f\u5916\u673a\uff08\u9a71\u52a8\u7cfb\u7edf\u4e8c \u00b7 5\u53f0\u5185\u673a\uff09<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--orange);\">RAS-200FSXPN5Q<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u91cf<\/td><td>20000 W<\/td><td>\u5236\u70ed\u91cf<\/td><td>22400 W<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u8fd0\u8f6c\u8303\u56f4<\/td><td>-5~60 \u2103<\/td><td>\u5236\u70ed\u8fd0\u8f6c\u8303\u56f4<\/td><td>-25~23 \u2103<\/td><\/tr>\n        <tr><td>APF<\/td><td>5.45<\/td><td>\u566a\u97f3\u503c<\/td><td>53\/55 dB(A)<\/td><\/tr>\n        <tr><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>1380\u00d7950\u00d7370 mm<\/td><td>\u8fde\u63a5\u7387<\/td><td>107.0%<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a<\/td><td>\u8865\u6c14\u589e\u7113\u6da1\u65cb\u5f0f<\/td><td>\u7535\u6e90<\/td><td>220V~50Hz<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u6c34\u6a21\u5757\u6280\u672f\u53c2\u6570<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--blue);\">RWMG-224FWXNZQ<\/td><\/tr>\n        <tr><td>\u989d\u5b9a\u5236\u70ed\u91cf<\/td><td>22400 W<\/td><td>\u989d\u5b9a\u529f\u7387<\/td><td>180 W<\/td><\/tr>\n        <tr><td>\u566a\u97f3\u503c<\/td><td>35 dB(A)<\/td><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>890\u00d7520\u00d7320 mm<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <h4 style=\"margin:16px 0 8px;\">\u7cfb\u7edf\u4e00 \u00b7 \u7a7a\u8c03\u5185\u673a\u914d\u7f6e\uff083\u53f0 \u00b7 EX\u8212\u4eabDC\u6807\u51c6\u5185\u673a\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u989d\u5b9a\u51b7\u91cf(W)<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u5c3a\u5bf8(mm)<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4(\u8fde\u901a)<\/td><td>77<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>7,100<\/td><td>35\/33\/31\/28\/25\/22<\/td><td>192\u00d71180\u00d7447<\/td><td>2<\/td><\/tr>\n        <tr><td>\u4e66\u623f<\/td><td>11<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>1,800<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7550\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"3\">\u5408\u8ba1(\u7cfb\u7edf\u4e00)<\/td><td>16,000<\/td><td>-<\/td><td>-<\/td><td>3\u53f0 \/ 88\u33a1<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <h4 style=\"margin:16px 0 8px;\">\u7cfb\u7edf\u4e8c \u00b7 \u7a7a\u8c03\u5185\u673a\u914d\u7f6e\uff085\u53f0 \u00b7 \u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u989d\u5b9a\u51b7\u91cf(W)<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u5c3a\u5bf8(mm)<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u665a\u8f88\u623f(\u4e8c\u5c42)<\/td><td>19<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4,000<\/td><td>31\/28\/25\/23\/20\/18<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4(\u4e8c\u5c42)<\/td><td>19<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4,000<\/td><td>31\/28\/25\/23\/20\/18<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f(\u4e8c\u5c42)<\/td><td>15<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>3,200<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u5ba2\u623f(\u4e8c\u5c42)<\/td><td>11<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2,200<\/td><td>23\/22\/21\/20\/18\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u4e3b\u5367+\u8863\u5e3d\u95f4(\u4e09\u5c42)<\/td><td>43<\/td><td>RPIZ-80FSVN2QB\/PC<\/td><td>8,000<\/td><td>36\/33\/30\/27\/24\/22<\/td><td>192\u00d71180\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"3\">\u5408\u8ba1(\u7cfb\u7edf\u4e8c)<\/td><td>21,400<\/td><td>-<\/td><td>-<\/td><td>5\u53f0 \/ 107~110\u33a1<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <h4 style=\"margin:16px 0 8px;\">\u5730\u6696\u914d\u7f6e\uff0816\u56de\u8def 221.90\u33a1\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5730\u6696\u7ba1\u578b\u53f7<\/th><th>\u8bbe\u8ba1\u5236\u70ed\u91cf(W)<\/th><th>\u56de\u8def\u6570<\/th><th>\u76d8\u7ba1\u95f4\u8ddd(mm)<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u4e00\u5c42<\/td><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4(\u8fde\u901a)<\/td><td>75.77<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>10607<\/td><td>4<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e00\u5c42<\/td><td>\u4e66\u623f(\u8fde\u901a)<\/td><td>11.4<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1596<\/td><td>1<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f<\/td><td>19.6<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2744<\/td><td>2<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4<\/td><td>18.5<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2590<\/td><td>1<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f<\/td><td>14.4<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2016<\/td><td>1<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u5ba2\u623f<\/td><td>11.1<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1554<\/td><td>2<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u8fc7\u9053<\/td><td>16.66<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2332<\/td><td>1<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e09\u5c42<\/td><td>\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td>44.33<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>6206<\/td><td>3<\/td><td>175\/150<\/td><\/tr>\n        <tr><td>\u4e09\u5c42<\/td><td>\u8fc7\u9053<\/td><td>10.14<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1419<\/td><td>1<\/td><td>175\/150<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"2\">\u5408\u8ba1<\/td><td>221.90<\/td><td>-<\/td><td>31064<\/td><td>16<\/td><td>-<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n\n      <!-- \u65b9\u6848\u4e00 \u00b7 \u62a5\u4ef7\u533a -->\n      <div class=\"card\" style=\"margin-top:20px;\">\n        <h4 style=\"color:var(--orange);margin-bottom:10px;\">\ud83d\udccb \u8212\u4eab+\u5c0a\u777f\u5168\u6548 \u00b7 \u4f18\u60e0\u62a5\u4ef7<\/h4>\n        <div class=\"note nb\" style=\"margin-bottom:12px;\">\u8bbe\u5907\u9762\u4ef7<strong>8\u6298<\/strong>\u4f18\u60e0\uff08\u7ebf\u63a7\u5668\u9664\u5916\uff09\uff0c\u5730\u6696\u6309\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\u3002<\/div>\n        <!-- \u8bbe\u5907\u660e\u7ec6\u8868 -->\n        <h5 style=\"margin:8px 0 6px;color:var(--text);\">\u2460 \u8bbe\u5907\u6e05\u5355\uff08\u542b8\u6298\u4f18\u60e0\u4ef7\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:13px;\">\n          <thead><tr><th>\u7c7b\u522b<\/th><th>\u8bbe\u5907\u540d\u79f0\/\u578b\u53f7<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u9762\u4ef7<\/th><th style=\"text-align:right;\">\u9762\u4ef7\u5c0f\u8ba1<\/th><th style=\"text-align:right;color:#e67e22;\">8\u6298\u4f18\u60e0\u4ef7<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>\u5ba4\u5916\u673a<\/td><td>EX\u8212\u4eab\u53d8\u9891\u5916\u673a<br><span style=\"color:var(--text-light);font-size:12px;\">RAS-140HRNAQ<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a512,875<\/td><td style=\"text-align:right;\">\u00a512,875<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a510,300<\/td><\/tr>\n          <tr><td>\u5ba4\u5916\u673a<\/td><td>VAM\u5c0a\u777f\u5168\u6548II\u5916\u673a<br><span style=\"color:var(--text-light);font-size:12px;\">RAS-200FSXPN5Q<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a525,863<\/td><td style=\"text-align:right;\">\u00a525,863<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a520,690<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757<\/td><td>\u5c0a\u777f\u5168\u6548\u6c34\u6a21\u5757 22.4kW<br><span style=\"color:var(--text-light);font-size:12px;\">RWMG-224FWXNZQ<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a59,750<\/td><td style=\"text-align:right;\">\u00a59,750<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a57,800<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u4e00\u5185\u673a<\/td><td>EX\u8212\u4eabDC\u6807\u51c6\u5185\u673a 71\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-71FSNAQD\/P<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,513<\/td><td style=\"text-align:right;\">\u00a57,026<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a55,621<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u4e00\u5185\u673a<\/td><td>EX\u8212\u4eabDC\u6807\u51c6\u5185\u673a 18\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-18FSNAQD\/P<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a52,838<\/td><td style=\"text-align:right;\">\u00a52,838<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a52,270<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u4e8c\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 40\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-40FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;\">\u00a510,476<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a58,381<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u4e8c\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 32\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-32FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,190<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u4e8c\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 22\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-22FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,040<\/td><\/tr>\n          <tr><td>\u7cfb\u7edf\u4e8c\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 80\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-80FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a56,438<\/td><td style=\"text-align:right;\">\u00a56,438<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a55,150<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u8bbe\u5907\u5c0f\u8ba1\uff08\u4e0d\u542b\u7ebf\u63a7\u5668\uff09<\/td><td style=\"text-align:center;\">9\u53f0<\/td><td style=\"text-align:right;\"><\/td><td style=\"text-align:right;\">\u00a585,554<\/td><td style=\"text-align:right;color:#e67e22;\"><strong>\u00a568,442<\/strong><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u7ebf\u63a7\u5668 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2461 \u7ebf\u63a7\u5668\uff08\u6b63\u4ef7\uff0c\u4e0d\u53c2\u4e0e\u6298\u6263\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u578b\u53f7<\/th><th>\u540d\u79f0<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u5355\u4ef7<\/th><th style=\"text-align:right;\">\u5c0f\u8ba1<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>PC-WMH3Q<\/td><td>\u6c34\u6a21\u5757\u63a7\u5236\u5668<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5300<\/td><td style=\"text-align:right;\">\u00a5300<\/td><\/tr>\n          <tr><td>PC-P1HPQA<\/td><td>\u7cbe\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td style=\"text-align:center;\">5<\/td><td style=\"text-align:right;\">\u00a5476<\/td><td style=\"text-align:right;\">\u00a52,380<\/td><\/tr>\n          <tr><td>PC-P1HVQA<\/td><td>WiFi\u7ebf\u63a7\u5668<\/td><td style=\"text-align:center;\">3<\/td><td style=\"text-align:right;\">\u00a5200<\/td><td style=\"text-align:right;\">\u00a5600<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u7ebf\u63a7\u5668\u5408\u8ba1<\/td><td style=\"text-align:center;\">9\u53ea<\/td><td style=\"text-align:right;\"><\/td><td style=\"text-align:right;\">\u00a53,280<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u5b89\u88c5\u8d39\u660e\u7ec6 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2462 \u5b89\u88c5\u8d39\u7528\u660e\u7ec6<\/h5>\n        <table class=\"tbl install-tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u5b89\u88c5\u9879\u76ee<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u5b89\u88c5\u8d39<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>\u5916\u673a1 \u5b89\u88c5 RAS-140HRNAQ<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u5df2\u542b<\/td><\/tr>\n          <tr><td>\u5916\u673a2 \u5b89\u88c5 RAS-200FSXPN5Q<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5600<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757 \u5b89\u88c5 RWMG-224FWXNZQ<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5625<\/td><\/tr>\n          <tr><td>\u5185\u673a 71\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,200<\/td><\/tr>\n          <tr><td>\u5185\u673a 18\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,600<\/td><\/tr>\n          <tr><td>\u5185\u673a 40\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr><td>\u5185\u673a 32\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 22\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 80\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/td><td style=\"text-align:right;\"><strong>\u00a515,525<\/strong><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u5730\u6696 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2463 \u5730\u6696\u7cfb\u7edf\uff08\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u9762\u79ef<\/th><th>\u4f18\u60e0\u5355\u4ef7<\/th><th style=\"text-align:right;\">\u603b\u4ef7<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>221.90\u33a1<\/td><td>\u00a5169\/\u33a1<\/td><td style=\"text-align:right;\">\u00a537,501<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u603b\u4ef7\u5361\u7247 -->\n        <div style=\"display:flex;gap:12px;flex-wrap:wrap;margin-top:18px;\">\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u8bbe\u59078\u6298\u540e\uff08\u542b\u7ebf\u63a7\u5668\uff09<\/p>\n            <p style=\"font-size:18px;font-weight:700;\">\u00a571,723<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u00a568,442(\u8bbe\u59078\u6298)+\u00a53,280(\u7ebf\u63a7\u5668)<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u5b89\u88c5\u8d39<\/p>\n            <p style=\"font-size:18px;font-weight:700;color:#e67e22;\">\u00a515,525<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u660e\u7ec6\u89c1\u4e0a<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u5730\u6696 \u00a5169\/\u33a1<\/p>\n            <p style=\"font-size:18px;font-weight:700;\">\u00a537,501<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">221.90\u33a1<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u603b\u4ef7<\/p>\n            <p style=\"font-size:18px;font-weight:700;color:var(--text-light);\">\u00a5124,749<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u9762\u4ef7\u00a5145,400 \u2192 \u7701\u00a520,651<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:160px;padding:14px;text-align:center;background:var(--orange);color:#fff;\">\n            <p style=\"font-size:12px;opacity:0.9;\">\u4f18\u60e0\u603b\u4ef7<\/p>\n            <p class=\"price-tag\" style=\"color:#fff;\">\u00a5124,749<\/p>\n            <p style=\"font-size:11px;opacity:0.9;\">\u6bd4\u9762\u4ef7\u7701 \u00a520,651<\/p>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- ========== \u65b9\u6848\u4e8c ========== -->\n    <div class=\"tab-pane\" id=\"tab-2\">\n      <h3 style=\"color:var(--blue);margin:20px 0 12px;\">\u65b9\u6848\u4e8c \u00b7 VAM\u5c0a\u777f\u5168\u6548 30kW\uff08380V \u5355\u5916\u673a\uff09<\/h3>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u5ba4\u5916\u673a\u6280\u672f\u53c2\u6570<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--blue);\">RAS-300FSXPNY5Q<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u91cf<\/td><td>30000 W<\/td><td>\u5236\u70ed\u91cf<\/td><td>31500 W<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u8fd0\u8f6c\u8303\u56f4<\/td><td>-5~60 \u2103<\/td><td>\u5236\u70ed\u8fd0\u8f6c\u8303\u56f4<\/td><td>-25~23 \u2103<\/td><\/tr>\n        <tr><td>APF<\/td><td>5.2<\/td><td>\u566a\u97f3\u503c<\/td><td>56\/58 dB(A)<\/td><\/tr>\n        <tr><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>1650\u00d71250\u00d7440 mm<\/td><td>\u8fde\u63a5\u7387<\/td><td>128.7%<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a<\/td><td>\u8865\u6c14\u589e\u7113\u6da1\u65cb\u5f0f<\/td><td>\u7535\u6e90<\/td><td>380V 3N~50Hz<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <div class=\"note ng\" style=\"margin-top:10px;\">\ud83d\udca1 <strong>\u8fde\u63a5\u7387\u8bf4\u660e\uff1a<\/strong>\u65b9\u6848\u4e8c\u603b\u5185\u673a\u51b7\u91cf38,600W \u00f7 \u5916\u673a\u5236\u51b7\u91cf30,000W = <strong>128.7%<\/strong>\uff0c\u5728\u65e5\u7acbSET-FREE\u7cfb\u5217\u63a8\u8350\u8303\u56f4\u5185\uff08100%~130%\uff09\u3002\u65e5\u5e38\u4f7f\u7528\u5b8c\u5168\u5b89\u5168\uff0c\u5373\u4f7f7\u5ba4\u540c\u65f6\u5168\u5f00\u4e5f\u80fd\u4fdd\u8bc1\u8db3\u591f\u5236\u51b7\u6548\u679c\u3002<\/div>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u6c34\u6a21\u5757\u6280\u672f\u53c2\u6570<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--blue);\">RWMG-280FWXNZQ<\/td><\/tr>\n        <tr><td>\u989d\u5b9a\u5236\u70ed\u91cf<\/td><td>28000 W<\/td><td>\u989d\u5b9a\u529f\u7387<\/td><td>280 W<\/td><\/tr>\n        <tr><td>\u566a\u97f3\u503c<\/td><td>39 dB(A)<\/td><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>890\u00d7520\u00d7320 mm<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <h4 style=\"margin:16px 0 8px;\">\u7a7a\u8c03\u5185\u673a\u914d\u7f6e\uff089\u53f0\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u989d\u5b9a\u51b7\u91cf(W)<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u5c3a\u5bf8(mm)<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4(\u8fde\u901a)<\/td><td>77<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>7,100<\/td><td>33\/31\/28\/25\/23\/22<\/td><td>192\u00d71180\u00d7447<\/td><td>2<\/td><\/tr>\n        <tr><td>\u4e66\u623f<\/td><td>11<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2,200<\/td><td>23\/22\/21\/20\/18\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f(\u4e8c\u5c42)<\/td><td>19.6<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4,000<\/td><td>31\/28\/25\/23\/20\/18<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4(\u4e8c\u5c42)<\/td><td>18.5<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>3,600<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f(\u4e8c\u5c42)<\/td><td>14.8<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>2,800<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u5ba2\u623f(\u4e8c\u5c42)<\/td><td>14.4<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>2,800<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u4e3b\u5367+\u8863\u5e3d\u95f4(\u4e09\u5c42)<\/td><td>43<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>4,500<\/td><td>31\/28\/25\/23\/20\/18<\/td><td>192\u00d7700\u00d7447<\/td><td>2<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"3\">\u5408\u8ba1<\/td><td>38,600<\/td><td>-<\/td><td>-<\/td><td>9\u53f0 \/ 195~198\u33a1<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <h4 style=\"margin:16px 0 8px;\">\u5730\u6696\u914d\u7f6e\uff0816\u56de\u8def 221.90\u33a1\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5730\u6696\u7ba1\u578b\u53f7<\/th><th>\u8bbe\u8ba1\u5236\u70ed\u91cf(W)<\/th><th>\u56de\u8def\u6570<\/th><th>\u76d8\u7ba1\u95f4\u8ddd(mm)<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u4e00\u5c42<\/td><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4(\u8fde\u901a)<\/td><td>75.77<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>10607<\/td><td>4<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e00\u5c42<\/td><td>\u4e66\u623f(\u8fde\u901a)<\/td><td>11.4<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1596<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f<\/td><td>19.6<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2744<\/td><td>2<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4<\/td><td>18.5<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2590<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f<\/td><td>14.4<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2016<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u5ba2\u623f<\/td><td>11.1<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1554<\/td><td>2<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u8fc7\u9053<\/td><td>16.66<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2332<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e09\u5c42<\/td><td>\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td>44.33<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>6206<\/td><td>3<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e09\u5c42<\/td><td>\u8fc7\u9053<\/td><td>10.14<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1419<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"2\">\u5408\u8ba1<\/td><td>221.90<\/td><td>-<\/td><td>31064<\/td><td>16<\/td><td>-<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n\n      <!-- \u65b9\u6848\u4e8c \u00b7 \u62a5\u4ef7\u533a -->\n      <div class=\"card edge-b\" style=\"margin-top:20px;\">\n        <h4 style=\"color:var(--blue);margin-bottom:10px;\">\ud83d\udccb VAM\u5c0a\u777f\u5168\u6548 30kW \u00b7 \u4f18\u60e0\u62a5\u4ef7<\/h4>\n        <div class=\"note nb\" style=\"margin-bottom:12px;\">\u8bbe\u5907\u9762\u4ef7<strong>8\u6298<\/strong>\u4f18\u60e0\uff08\u7ebf\u63a7\u5668\u9664\u5916\uff09\uff0c\u5730\u6696\u6309\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\u3002<\/div>\n        <!-- \u8bbe\u5907\u660e\u7ec6\u8868 -->\n        <h5 style=\"margin:8px 0 6px;color:var(--text);\">\u2460 \u8bbe\u5907\u6e05\u5355\uff08\u542b8\u6298\u4f18\u60e0\u4ef7\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:13px;\">\n          <thead><tr><th>\u7c7b\u522b<\/th><th>\u8bbe\u5907\u540d\u79f0\/\u578b\u53f7<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u9762\u4ef7<\/th><th style=\"text-align:right;\">\u9762\u4ef7\u5c0f\u8ba1<\/th><th style=\"text-align:right;color:#e67e22;\">8\u6298\u4f18\u60e0\u4ef7<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>\u5ba4\u5916\u673a<\/td><td>VAM\u5c0a\u777f\u5168\u6548II\u5916\u673a<br><span style=\"color:var(--text-light);font-size:12px;\">RAS-300FSXPNY5Q<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a534,788<\/td><td style=\"text-align:right;\">\u00a534,788<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a527,830<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757<\/td><td>\u5c0a\u777f\u5168\u6548\u6c34\u6a21\u5757 30kW<br><span style=\"color:var(--text-light);font-size:12px;\">RWMG-280FWXNZQ<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a511,250<\/td><td style=\"text-align:right;\">\u00a511,250<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a59,000<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 71\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-71FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a55,825<\/td><td style=\"text-align:right;\">\u00a511,650<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a59,320<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 22\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-22FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,040<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 40\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-40FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,190<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 36\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-36FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,190<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 28\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-28FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;\">\u00a510,100<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a58,080<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 45\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-45FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a55,563<\/td><td style=\"text-align:right;\">\u00a511,126<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a58,901<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u8bbe\u5907\u5c0f\u8ba1\uff08\u4e0d\u542b\u7ebf\u63a7\u5668\uff09<\/td><td style=\"text-align:center;\">9\u53f0<\/td><td style=\"text-align:right;\"><\/td><td style=\"text-align:right;\">\u00a594,440<\/td><td style=\"text-align:right;color:#e67e22;\"><strong>\u00a575,551<\/strong><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u7ebf\u63a7\u5668 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2461 \u7ebf\u63a7\u5668\uff08\u6b63\u4ef7\uff0c\u4e0d\u53c2\u4e0e\u6298\u6263\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u578b\u53f7<\/th><th>\u540d\u79f0<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u5355\u4ef7<\/th><th style=\"text-align:right;\">\u5c0f\u8ba1<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>PC-WMH3Q<\/td><td>\u6c34\u6a21\u5757\u63a7\u5236\u5668<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5300<\/td><td style=\"text-align:right;\">\u00a5300<\/td><\/tr>\n          <tr><td>PC-P1HPQA<\/td><td>\u7cbe\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td style=\"text-align:center;\">9<\/td><td style=\"text-align:right;\">\u00a5476<\/td><td style=\"text-align:right;\">\u00a54,284<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u7ebf\u63a7\u5668\u5408\u8ba1<\/td><td style=\"text-align:center;\">10\u53ea<\/td><td style=\"text-align:right;\"><\/td><td style=\"text-align:right;\">\u00a54,584<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u5b89\u88c5\u8d39\u660e\u7ec6 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2462 \u5b89\u88c5\u8d39\u7528\u660e\u7ec6<\/h5>\n        <table class=\"tbl install-tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u5b89\u88c5\u9879\u76ee<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u5b89\u88c5\u8d39<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>\u5916\u673a \u5b89\u88c5 RAS-300FSXPNY5Q<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5600<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757 \u5b89\u88c5 RWMG-280FWXNZQ<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5625<\/td><\/tr>\n          <tr><td>\u5185\u673a 71\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr><td>\u5185\u673a 22\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 40\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 36\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 28\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr><td>\u5185\u673a 45\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/td><td style=\"text-align:right;\"><strong>\u00a518,325<\/strong><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u5730\u6696 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2463 \u5730\u6696\u7cfb\u7edf\uff08\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u9762\u79ef<\/th><th>\u4f18\u60e0\u5355\u4ef7<\/th><th style=\"text-align:right;\">\u603b\u4ef7<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>221.90\u33a1<\/td><td>\u00a5169\/\u33a1<\/td><td style=\"text-align:right;\">\u00a537,501<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u603b\u4ef7\u5361\u7247 -->\n        <div style=\"display:flex;gap:12px;flex-wrap:wrap;margin-top:18px;\">\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u8bbe\u59078\u6298\u540e\uff08\u542b\u7ebf\u63a7\u5668\uff09<\/p>\n            <p style=\"font-size:18px;font-weight:700;\">\u00a580,135<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u00a575,551(\u8bbe\u59078\u6298)+\u00a54,584(\u7ebf\u63a7\u5668)<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u5b89\u88c5\u8d39<\/p>\n            <p style=\"font-size:18px;font-weight:700;color:#e67e22;\">\u00a518,325<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u660e\u7ec6\u89c1\u4e0a<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u5730\u6696 \u00a5169\/\u33a1<\/p>\n            <p style=\"font-size:18px;font-weight:700;\">\u00a537,501<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">221.90\u33a1<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u603b\u4ef7<\/p>\n            <p style=\"font-size:18px;font-weight:700;color:var(--text-light);\">\u00a5135,961<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u9762\u4ef7\u00a5158,390 \u2192 \u7701\u00a522,429<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:160px;padding:14px;text-align:center;background:var(--orange);color:#fff;\">\n            <p style=\"font-size:12px;opacity:0.9;\">\u4f18\u60e0\u603b\u4ef7<\/p>\n            <p class=\"price-tag\" style=\"color:#fff;\">\u00a5135,961<\/p>\n            <p style=\"font-size:11px;opacity:0.9;\">\u6bd4\u9762\u4ef7\u7701 \u00a522,429<\/p>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- ========== \u65b9\u6848\u4e09 ========== -->\n    <div class=\"tab-pane\" id=\"tab-3\">\n      <h3 style=\"color:var(--blue);margin:20px 0 12px;\">\u65b9\u6848\u4e09 \u00b7 VAM\u5c0a\u777f\u5168\u6548 33.5kW\uff08380V \u5355\u5916\u673a\uff09<\/h3>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u5ba4\u5916\u673a\u6280\u672f\u53c2\u6570<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--blue);\">RAS-335FSXPN5Q<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u91cf<\/td><td>33500 W<\/td><td>\u5236\u70ed\u91cf<\/td><td>37500 W<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u8fd0\u8f6c\u8303\u56f4<\/td><td>-5~60 \u2103<\/td><td>\u5236\u70ed\u8fd0\u8f6c\u8303\u56f4<\/td><td>-25~23 \u2103<\/td><\/tr>\n        <tr><td>APF<\/td><td>5.2<\/td><td>\u566a\u97f3\u503c<\/td><td>58\/60 dB(A)<\/td><\/tr>\n        <tr><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>1650\u00d71250\u00d7440 mm<\/td><td>\u8fde\u63a5\u7387<\/td><td>123.0%<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a<\/td><td>\u8865\u6c14\u589e\u7113\u6da1\u65cb\u5f0f<\/td><td>\u7535\u6e90<\/td><td>380V 3N~50Hz<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <div class=\"card\">\n        <h4 style=\"margin-bottom:8px;\">\u6c34\u6a21\u5757\u6280\u672f\u53c2\u6570<\/h4>\n        <table class=\"tbl\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><th>\u53c2\u6570<\/th><th>\u6570\u503c<\/th><\/tr><\/thead><tbody>\n        <tr><td><strong>\u578b\u53f7<\/strong><\/td><td colspan=\"3\" style=\"text-align:left;font-size:16px;color:var(--blue);\">RWMG-335FWXNZQ<\/td><\/tr>\n        <tr><td>\u989d\u5b9a\u5236\u70ed\u91cf<\/td><td>33500 W<\/td><td>\u989d\u5b9a\u529f\u7387<\/td><td>350 W<\/td><\/tr>\n        <tr><td>\u566a\u97f3\u503c<\/td><td>39 dB(A)<\/td><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>890\u00d7520\u00d7320 mm<\/td><\/tr><\/tbody><\/table>\n      <\/div>\n      <h4 style=\"margin:16px 0 8px;\">\u7a7a\u8c03\u5185\u673a\u914d\u7f6e\uff089\u53f0\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u989d\u5b9a\u51b7\u91cf(W)<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u5c3a\u5bf8(mm)<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4(\u8fde\u901a)<\/td><td>77<\/td><td>RPIZ-80FSVN2QB\/PC<\/td><td>8,000<\/td><td>36\/33\/30\/27\/24\/22<\/td><td>192\u00d71180\u00d7447<\/td><td>2<\/td><\/tr>\n        <tr><td>\u4e66\u623f<\/td><td>11<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2,200<\/td><td>23\/22\/21\/20\/18\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f(\u4e8c\u5c42)<\/td><td>19.6<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4,000<\/td><td>31\/28\/25\/23\/20\/18<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4(\u4e8c\u5c42)<\/td><td>18.5<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>3,600<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f(\u4e8c\u5c42)<\/td><td>14.8<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>3,600<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u5ba2\u623f(\u4e8c\u5c42)<\/td><td>14.4<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>2,800<\/td><td>27\/25\/23\/21\/19\/17<\/td><td>192\u00d7700\u00d7447<\/td><td>1<\/td><\/tr>\n        <tr><td>\u4e3b\u5367+\u8863\u5e3d\u95f4(\u4e09\u5c42)<\/td><td>43<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>4,500<\/td><td>31\/28\/25\/23\/20\/18<\/td><td>192\u00d7700\u00d7447<\/td><td>2<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"3\">\u5408\u8ba1<\/td><td>41,200<\/td><td>-<\/td><td>-<\/td><td>9\u53f0 \/ 195~198\u33a1<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <h4 style=\"margin:16px 0 8px;\">\u5730\u6696\u914d\u7f6e\uff0816\u56de\u8def 221.90\u33a1\uff09<\/h4>\n      <table class=\"tbl\">\n        <thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5730\u6696\u7ba1\u578b\u53f7<\/th><th>\u8bbe\u8ba1\u5236\u70ed\u91cf(W)<\/th><th>\u56de\u8def\u6570<\/th><th>\u76d8\u7ba1\u95f4\u8ddd(mm)<\/th><\/tr><\/thead>\n        <tbody>\n        <tr><td>\u4e00\u5c42<\/td><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4(\u8fde\u901a)<\/td><td>75.77<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>10607<\/td><td>4<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e00\u5c42<\/td><td>\u4e66\u623f(\u8fde\u901a)<\/td><td>11.4<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1596<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f<\/td><td>19.6<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2744<\/td><td>2<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4<\/td><td>18.5<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2590<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u665a\u8f88\u623f<\/td><td>14.4<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2016<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u5ba2\u623f<\/td><td>11.1<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1554<\/td><td>2<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e8c\u5c42<\/td><td>\u8fc7\u9053<\/td><td>16.66<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>2332<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e09\u5c42<\/td><td>\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td>44.33<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>6206<\/td><td>3<\/td><td>175<\/td><\/tr>\n        <tr><td>\u4e09\u5c42<\/td><td>\u8fc7\u9053<\/td><td>10.14<\/td><td>PE-RT dn20\u00d7en2.0<\/td><td>1419<\/td><td>1<\/td><td>175<\/td><\/tr>\n        <tr class=\"total-row\"><td colspan=\"2\">\u5408\u8ba1<\/td><td>221.90<\/td><td>-<\/td><td>31064<\/td><td>16<\/td><td>-<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n\n      <!-- \u65b9\u6848\u4e09 \u00b7 \u62a5\u4ef7\u533a -->\n      <div class=\"card edge-g\" style=\"margin-top:20px;\">\n        <h4 style=\"color:var(--green);margin-bottom:10px;\">\ud83d\udccb VAM\u5c0a\u777f\u5168\u6548 33.5kW \u00b7 \u4f18\u60e0\u62a5\u4ef7<\/h4>\n        <div class=\"note nb\" style=\"margin-bottom:12px;\">\u8bbe\u5907\u9762\u4ef7<strong>8\u6298<\/strong>\u4f18\u60e0\uff08\u7ebf\u63a7\u5668\u9664\u5916\uff09\uff0c\u5730\u6696\u6309\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\u3002<\/div>\n        <!-- \u8bbe\u5907\u660e\u7ec6\u8868 -->\n        <h5 style=\"margin:8px 0 6px;color:var(--text);\">\u2460 \u8bbe\u5907\u6e05\u5355\uff08\u542b8\u6298\u4f18\u60e0\u4ef7\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:13px;\">\n          <thead><tr><th>\u7c7b\u522b<\/th><th>\u8bbe\u5907\u540d\u79f0\/\u578b\u53f7<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u9762\u4ef7<\/th><th style=\"text-align:right;\">\u9762\u4ef7\u5c0f\u8ba1<\/th><th style=\"text-align:right;color:#e67e22;\">8\u6298\u4f18\u60e0\u4ef7<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>\u5ba4\u5916\u673a<\/td><td>VAM\u5c0a\u777f\u5168\u6548II\u5916\u673a<br><span style=\"color:var(--text-light);font-size:12px;\">RAS-335FSXPN5Q<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a538,913<\/td><td style=\"text-align:right;\">\u00a538,913<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a531,130<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757<\/td><td>\u5c0a\u777f\u5168\u6548\u6c34\u6a21\u5757 33.5kW<br><span style=\"color:var(--text-light);font-size:12px;\">RWMG-335FWXNZQ<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a512,500<\/td><td style=\"text-align:right;\">\u00a512,500<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a510,000<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 80\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-80FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a56,438<\/td><td style=\"text-align:right;\">\u00a512,876<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a510,301<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 22\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-22FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,040<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 40\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-40FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,190<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 36\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-36FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a55,238<\/td><td style=\"text-align:right;\">\u00a510,476<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a58,381<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 28\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-28FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;\">\u00a55,050<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a54,040<\/td><\/tr>\n          <tr><td>\u5185\u673a<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a 45\u578b<br><span style=\"color:var(--text-light);font-size:12px;\">RPIZ-45FSVN2QB\/PC<\/span><\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a55,563<\/td><td style=\"text-align:right;\">\u00a511,126<\/td><td style=\"text-align:right;color:#e67e22;\">\u00a58,901<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u8bbe\u5907\u5c0f\u8ba1\uff08\u4e0d\u542b\u7ebf\u63a7\u5668\uff09<\/td><td style=\"text-align:center;\">9\u53f0<\/td><td style=\"text-align:right;\"><\/td><td style=\"text-align:right;\">\u00a5101,229<\/td><td style=\"text-align:right;color:#e67e22;\"><strong>\u00a580,983<\/strong><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u7ebf\u63a7\u5668 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2461 \u7ebf\u63a7\u5668\uff08\u6b63\u4ef7\uff0c\u4e0d\u53c2\u4e0e\u6298\u6263\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u578b\u53f7<\/th><th>\u540d\u79f0<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u5355\u4ef7<\/th><th style=\"text-align:right;\">\u5c0f\u8ba1<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>PC-WMH3Q<\/td><td>\u6c34\u6a21\u5757\u63a7\u5236\u5668<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5300<\/td><td style=\"text-align:right;\">\u00a5300<\/td><\/tr>\n          <tr><td>PC-P1HPQA<\/td><td>\u7cbe\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td style=\"text-align:center;\">9<\/td><td style=\"text-align:right;\">\u00a5476<\/td><td style=\"text-align:right;\">\u00a54,284<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u7ebf\u63a7\u5668\u5408\u8ba1<\/td><td style=\"text-align:center;\">10\u53ea<\/td><td style=\"text-align:right;\"><\/td><td style=\"text-align:right;\">\u00a54,584<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u5b89\u88c5\u8d39\u660e\u7ec6 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2462 \u5b89\u88c5\u8d39\u7528\u660e\u7ec6<\/h5>\n        <table class=\"tbl install-tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u5b89\u88c5\u9879\u76ee<\/th><th style=\"text-align:center;\">\u6570\u91cf<\/th><th style=\"text-align:right;\">\u5b89\u88c5\u8d39<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>\u5916\u673a \u5b89\u88c5 RAS-335FSXPN5Q<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5600<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757 \u5b89\u88c5 RWMG-335FWXNZQ<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a5625<\/td><\/tr>\n          <tr><td>\u5185\u673a 80\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr><td>\u5185\u673a 22\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 40\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 36\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr><td>\u5185\u673a 28\u578b \u5b89\u88c5 \u00d71<\/td><td style=\"text-align:center;\">1<\/td><td style=\"text-align:right;\">\u00a51,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 45\u578b \u5b89\u88c5 \u00d72<\/td><td style=\"text-align:center;\">2<\/td><td style=\"text-align:right;\">\u00a53,800<\/td><\/tr>\n          <tr class=\"total-row\"><td colspan=\"2\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/td><td style=\"text-align:right;\"><strong>\u00a518,325<\/strong><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u5730\u6696 -->\n        <h5 style=\"margin:12px 0 6px;color:var(--text);\">\u2463 \u5730\u6696\u7cfb\u7edf\uff08\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\uff09<\/h5>\n        <table class=\"tbl\" style=\"font-size:12px;\">\n          <thead><tr><th>\u9762\u79ef<\/th><th>\u4f18\u60e0\u5355\u4ef7<\/th><th style=\"text-align:right;\">\u603b\u4ef7<\/th><\/tr><\/thead>\n          <tbody>\n          <tr><td>221.90\u33a1<\/td><td>\u00a5169\/\u33a1<\/td><td style=\"text-align:right;\">\u00a537,501<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <!-- \u603b\u4ef7\u5361\u7247 -->\n        <div style=\"display:flex;gap:12px;flex-wrap:wrap;margin-top:18px;\">\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u8bbe\u59078\u6298\u540e\uff08\u542b\u7ebf\u63a7\u5668\uff09<\/p>\n            <p style=\"font-size:18px;font-weight:700;\">\u00a585,567<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u00a580,983(\u8bbe\u59078\u6298)+\u00a54,584(\u7ebf\u63a7\u5668)<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u5b89\u88c5\u8d39<\/p>\n            <p style=\"font-size:18px;font-weight:700;color:#e67e22;\">\u00a518,325<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u660e\u7ec6\u89c1\u4e0a<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u5730\u6696 \u00a5169\/\u33a1<\/p>\n            <p style=\"font-size:18px;font-weight:700;\">\u00a537,501<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">221.90\u33a1<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:140px;padding:12px;text-align:center;\">\n            <p style=\"color:var(--text-light);font-size:12px;\">\u603b\u4ef7<\/p>\n            <p style=\"font-size:18px;font-weight:700;color:var(--text-light);\">\u00a5141,393<\/p>\n            <p style=\"color:var(--text-light);font-size:10px;\">\u9762\u4ef7\u00a5165,179 \u2192 \u7701\u00a523,786<\/p>\n          <\/div>\n          <div class=\"card\" style=\"flex:1;min-width:160px;padding:14px;text-align:center;background:var(--orange);color:#fff;\">\n            <p style=\"font-size:12px;opacity:0.9;\">\u4f18\u60e0\u603b\u4ef7<\/p>\n            <p class=\"price-tag\" style=\"color:#fff;\">\u00a5141,393<\/p>\n            <p style=\"font-size:11px;opacity:0.9;\">\u6bd4\u9762\u4ef7\u7701 \u00a523,786<\/p>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-compare \u4e09\u65b9\u6848\u6838\u5fc3\u5bf9\u6bd4 ========== -->\n<section class=\"sec\" id=\"sec-compare\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u6838\u5fc3\u5bf9\u6bd4<\/div>\n  <h2 class=\"sec-title\">\u4e09\u65b9\u6848\u6838\u5fc3\u5bf9\u6bd4\u4e00\u89c8<\/h2>\n  <div class=\"note nb\">\u4ee5\u4e0b\u4e3a\u4e09\u65b9\u6848\u6838\u5fc3\u6280\u672f\u53c2\u6570\u3001\u529f\u80fd\u5dee\u5f02\u3001\u914d\u7f6e\u5dee\u5f02\u3001\u6210\u672c\u4f30\u7b97\u7684\u7cfb\u7edf\u6a2a\u5411\u5bf9\u6bd4\uff0c\u5e2e\u52a9\u60a8\u4e00\u76ee\u4e86\u7136\u505a\u51fa\u9009\u578b\u51b3\u7b56\u3002<\/div>\n\n  <!-- 1. \u6280\u672f\u53c2\u6570\u4e09\u5217\u5bf9\u6bd4\u8868 -->\n  <div class=\"card edge-b\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\ud83d\udcca 1. \u5916\u673a\u6280\u672f\u53c2\u6570\u6a2a\u5411\u5bf9\u6bd4<\/h3>\n    <table class=\"tbl tbl-cmp\">\n      <thead><tr><th style=\"width:140px;\">\u53c2\u6570<\/th><th>\u65b9\u6848\u4e00\uff08\u8212\u4eab+\u5c0a\u777f\uff09<\/th><th>\u65b9\u6848\u4e8c\uff08\u5c0a\u777f 30kW\uff09<\/th><th>\u65b9\u6848\u4e09\uff08\u5c0a\u777f 33.5kW\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5916\u673a\u578b\u53f7<\/td><td>RAS-140HRNAQ<br>+RAS-200FSXPN5Q<\/td><td>RAS-300FSXPNY5Q<\/td><td>RAS-335FSXPN5Q<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u91cf<\/td><td>14,000+20,000=34,000W<\/td><td>30,000W<\/td><td>33,500W<\/td><\/tr>\n        <tr><td>\u5236\u70ed\u91cf<\/td><td>16,000+22,400=38,400W<\/td><td>31,500W<\/td><td>37,500W<\/td><\/tr>\n        <tr><td>APF\u80fd\u6548<\/td><td style=\"color:var(--green);font-weight:700;\">5.8 \/ 5.45<\/td><td>5.2<\/td><td>5.2<\/td><\/tr>\n        <tr><td>\u566a\u97f3\u503c<\/td><td style=\"color:var(--green);font-weight:700;\">54 \/ 53\u00b755 dB(A)<\/td><td>56 \/ 58 dB(A)<\/td><td>58 \/ 60 dB(A)<\/td><\/tr>\n        <tr><td>\u5236\u70ed\u4e0b\u9650<\/td><td>-21\u2103 \/ -25\u2103<\/td><td style=\"color:var(--green);font-weight:700;\">-25\u2103<\/td><td style=\"color:var(--green);font-weight:700;\">-25\u2103<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a<\/td><td>\u53d8\u9891\u53cc\u8f6c\u5b50+\u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u8865\u6c14\u589e\u7113\u6da1\u65cb\u5f0f<\/td><td>\u8865\u6c14\u589e\u7113\u6da1\u65cb\u5f0f<\/td><\/tr>\n        <tr><td>\u7535\u6e90<\/td><td style=\"color:var(--green);font-weight:700;\">220V\uff08\u65e0\u9700\u6539\u9020\uff09<\/td><td>380V 3N<\/td><td>380V 3N<\/td><\/tr>\n        <tr><td>\u5916\u673a\u53f0\u6570<\/td><td>2\u53f0\uff08\u53cc\u7cfb\u7edf\uff09<\/td><td>1\u53f0<\/td><td>1\u53f0<\/td><\/tr>\n        <tr><td>\u5185\u673a\u53f0\u6570<\/td><td>8\u53f0\uff083+5\uff09<\/td><td>9\u53f0\uff083+6\uff09<\/td><td>9\u53f0\uff083+6\uff09<\/td><\/tr>\n        <tr><td>\u603b\u5185\u673a\u51b7\u91cf<\/td><td>37,400W<\/td><td>38,600W<\/td><td>41,200W<\/td><\/tr>\n        <tr><td>\u8fde\u63a5\u7387<\/td><td>114.3% \/ 107.0%<br><span style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/span><\/td><td>128.7%<br><span style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/span><\/td><td>123.0%<br><span style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/span><\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 2. \u529f\u80fd\u5dee\u5f02\u77e9\u9635 -->\n  <div class=\"card\">\n    <h3 style=\"color:var(--orange);margin-bottom:12px;\">\ud83d\udccb 2. \u529f\u80fd\u5dee\u5f02\u77e9\u9635 \u00b7 \u4e3a\u4ec0\u4e48\u65b9\u6848\u4e00\u66f4\u4fbf\u5b9c\uff1f<\/h3>\n    <table class=\"tbl tbl-cmp\">\n      <thead><tr><th style=\"width:160px;\">\u529f\u80fd\u7279\u6027<\/th><th>\u65b9\u6848\u4e00\uff08\u8212\u4eab+\u5c0a\u777f\uff09<\/th><th>\u65b9\u6848\u4e8c\/\u4e09\uff08\u5c0a\u777f\u5168\u6548\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u7cfb\u7edf\u4e00\u5185\u673a\u7cfb\u5217<\/td><td>EX\u8212\u4eabDC\u6807\u51c6\u5185\u673a\uff08FSNAQD\/P\uff09<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\uff08FSVN2QB\/PC\uff09<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u4e8c\u5185\u673a\u7cfb\u5217<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\uff08FSVN2QB\/PC\uff09<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u51c0\u5316\uff08FSVN2QB\/PC\uff09<\/td><\/tr>\n        <tr><td>\u7ba1\u5236\u7c7b\u578b<\/td><td>\u7cfb\u7edf\u4e00\uff1a\u4e24\u7ba1\u5236 \/ \u7cfb\u7edf\u4e8c\uff1a\u4e09\u7ba1\u5236<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5168\u7ebf\u4e09\u7ba1\u5236<\/td><\/tr>\n        <tr><td>\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236<\/td><td>\u7cfb\u7edf\u4e00\u4e0d\u652f\u6301 \/ \u7cfb\u7edf\u4e8c\u652f\u6301<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5168\u7ebf\u652f\u6301<\/td><\/tr>\n        <tr><td>\u4e0d\u5439\u6c34\u6280\u672f<\/td><td>\u7cfb\u7edf\u4e00\u4e0d\u652f\u6301 \/ \u7cfb\u7edf\u4e8c\u652f\u6301<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5168\u7ebf\u652f\u6301<\/td><\/tr>\n        <tr><td>\u81ea\u6e05\u6d01+\u9ad8\u6e29\u9664\u83cc<\/td><td style=\"color:var(--green);\">\u2713 \u652f\u6301<\/td><td style=\"color:var(--green);\">\u2713 \u652f\u6301<\/td><\/tr>\n        <tr><td>\u7a7a\u6c14\u51c0\u5316\u529f\u80fd<\/td><td>\u7cfb\u7edf\u4e00\u65e0 \/ \u7cfb\u7edf\u4e8c\u6709<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5168\u7ebf\u914d\u5907<\/td><\/tr>\n        <tr><td>\u6e29\u63a7\u7cbe\u5ea6<\/td><td>\u00b10.5\u2103<\/td><td>\u00b10.5\u2103<\/td><\/tr>\n        <tr><td>\u7ebf\u63a7\u5668<\/td><td>WiFi+\u7cbe\u5f69\u5c4f\u6df7\u642d<\/td><td style=\"color:var(--orange);font-weight:600;\">\u5168\u7ebf\u7cbe\u5f69\u5c4f<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 3. \u8fde\u63a5\u7387\u8ba1\u7b97 -->\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:12px;\">\ud83d\udd22 3. \u8fde\u63a5\u7387\uff08\u8d85\u914d\u7387\uff09\u8ba1\u7b97\u89e3\u6790<\/h3>\n    <p style=\"font-size:13px;color:var(--text-light);margin-bottom:10px;\">\u8fde\u63a5\u7387 = \u5185\u673a\u603b\u5236\u51b7\u91cf \u00f7 \u5916\u673a\u989d\u5b9a\u5236\u51b7\u91cf\u3002\u65e5\u7acbSET-FREE\u7cfb\u5217\u63a8\u8350\u533a\u95f4\uff1a<strong>100%~130%<\/strong>\u3002<\/p>\n    <table class=\"tbl tbl-cmp\">\n      <thead><tr><th>\u65b9\u6848<\/th><th>\u5185\u673a\u603b\u51b7\u91cf<\/th><th>\u5916\u673a\u5236\u51b7\u91cf<\/th><th>\u8fde\u63a5\u7387<\/th><th>\u72b6\u6001<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u65b9\u6848\u4e00 \u00b7 \u7cfb\u7edf\u4e00<\/td><td>16,000W<\/td><td>14,000W<\/td><td><strong>114.3%<\/strong><\/td><td style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/td><\/tr>\n        <tr><td>\u65b9\u6848\u4e00 \u00b7 \u7cfb\u7edf\u4e8c<\/td><td>21,400W<\/td><td>20,000W<\/td><td><strong>107.0%<\/strong><\/td><td style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/td><\/tr>\n        <tr><td>\u65b9\u6848\u4e8c<\/td><td>38,600W<\/td><td>30,000W<\/td><td><strong>128.7%<\/strong><\/td><td style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/td><\/tr>\n        <tr><td>\u65b9\u6848\u4e09<\/td><td>41,200W<\/td><td>33,500W<\/td><td><strong>123.0%<\/strong><\/td><td style=\"color:var(--green);\">\u2713 \u5b89\u5168<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"note ng\" style=\"margin-top:10px;\">\ud83d\udca1 <strong>\u65b9\u6848\u4e8c\u8bf4\u660e\uff1a<\/strong>\u8fde\u63a5\u7387128.7%\u5728\u63a8\u8350\u8303\u56f4\u5185\uff08100%~130%\uff09\uff0c\u914d\u7f6e\u5408\u7406\u30027\u5ba4\u5168\u5f00\u4e5f\u80fd\u4fdd\u8bc1\u5145\u8db3\u5236\u51b7\u6548\u679c\u3002<\/div>\n  <\/div>\n\n  <!-- 4. \u623f\u95f4\u914d\u7f6e\u5bf9\u7167 -->\n  <div class=\"card\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\ud83c\udfe0 4. \u5404\u623f\u95f4\u5185\u673a\u914d\u7f6e\u5dee\u5f02\u5bf9\u7167<\/h3>\n    <table class=\"tbl tbl-cmp\">\n      <thead><tr><th style=\"width:160px;\">\u623f\u95f4<\/th><th>\u65b9\u6848\u4e00<\/th><th>\u65b9\u6848\u4e8c<\/th><th>\u65b9\u6848\u4e09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4<\/td><td>71\u578b\u00d72\uff0814,200W\uff09<\/td><td>71\u578b\u00d72\uff0814,200W\uff09<\/td><td style=\"color:var(--orange);font-weight:600;\">80\u578b\u00d72\uff0816,000W\uff09\u2191<\/td><\/tr>\n        <tr><td>\u4e66\u623f<\/td><td style=\"color:var(--text-light);\">18\u578b\uff081,800W\uff09<\/td><td>22\u578b\uff082,200W\uff09<\/td><td>22\u578b\uff082,200W\uff09<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f\u2460<\/td><td>40\u578b\uff084,000W\uff09<\/td><td>40\u578b\uff084,000W\uff09<\/td><td>40\u578b\uff084,000W\uff09<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f+\u8863\u5e3d\u95f4<\/td><td style=\"color:var(--orange);font-weight:600;\">40\u578b\uff084,000W\uff09\u2191<\/td><td>36\u578b\uff083,600W\uff09<\/td><td>36\u578b\uff083,600W\uff09<\/td><\/tr>\n        <tr><td>\u665a\u8f88\u623f\u2461<\/td><td>32\u578b\uff083,200W\uff09<\/td><td>28\u578b\uff082,800W\uff09<\/td><td style=\"color:var(--orange);font-weight:600;\">36\u578b\uff083,600W\uff09\u2191<\/td><\/tr>\n        <tr><td>\u5ba2\u623f<\/td><td>22\u578b\uff082,200W\uff09<\/td><td>28\u578b\uff082,800W\uff09<\/td><td>28\u578b\uff082,800W\uff09<\/td><\/tr>\n        <tr><td>\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td style=\"color:var(--text-light);\">80\u578b\u00d71\uff088,000W\uff09<\/td><td style=\"color:var(--orange);font-weight:600;\">45\u578b\u00d72\uff089,000W\uff09\u2191<\/td><td style=\"color:var(--orange);font-weight:600;\">45\u578b\u00d72\uff089,000W\uff09\u2191<\/td><\/tr>\n        <tr class=\"total-row\"><td>\u603b\u53f0\u6570 \/ \u603b\u51b7\u91cf<\/td><td>8\u53f0 \/ 37,400W<\/td><td>9\u53f0 \/ 38,600W<\/td><td>9\u53f0 \/ 41,200W<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 5. \u4f18\u60e0\u603b\u4ef7\u5bf9\u6bd4 -->\n  <div class=\"card edge-b\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\ud83d\udcb0 5. \u4f18\u60e0\u603b\u4ef7\u5bf9\u6bd4<\/h3>\n    <table class=\"tbl tbl-cmp\">\n      <thead><tr><th style=\"width:140px;\">\u9879\u76ee<\/th><th>\u65b9\u6848\u4e00<\/th><th>\u65b9\u6848\u4e8c<\/th><th>\u65b9\u6848\u4e09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8bbe\u5907\u9762\u4ef7\u5c0f\u8ba1\uff08\u4e0d\u542b\u7ebf\u63a7\u5668\uff09<\/td><td>\u00a585,554<\/td><td>\u00a594,440<\/td><td>\u00a5101,229<\/td><\/tr>\n        <tr><td>\u8bbe\u59078\u6298\u4f18\u60e0\u4ef7<\/td><td style=\"color:#e67e22;\">\u00a568,442<\/td><td style=\"color:#e67e22;\">\u00a575,551<\/td><td style=\"color:#e67e22;\">\u00a580,983<\/td><\/tr>\n        <tr><td>\u7ebf\u63a7\u5668\uff08\u6b63\u4ef7\uff09<\/td><td>\u00a53,280<\/td><td>\u00a54,584<\/td><td>\u00a54,584<\/td><\/tr>\n        <tr><td>\u5b89\u88c5\u8d39<\/td><td>\u00a515,525<\/td><td>\u00a518,325<\/td><td>\u00a518,325<\/td><\/tr>\n        <tr><td>\u5730\u6696 \u00a5169\/\u33a1<\/td><td>\u00a537,501<\/td><td>\u00a537,501<\/td><td>\u00a537,501<\/td><\/tr>\n        <tr class=\"total-row\"><td><strong>\u4f18\u60e0\u603b\u4ef7<\/strong><\/td><td style=\"font-size:18px;\"><strong>\u00a5124,749<\/strong><\/td><td style=\"font-size:18px;\"><strong>\u00a5135,961<\/strong><\/td><td style=\"font-size:18px;\"><strong>\u00a5141,393<\/strong><\/td><\/tr>\n        <tr><td>\u9762\u4ef7\u603b\u4ef7<\/td><td>\u00a5145,400<\/td><td>\u00a5158,390<\/td><td>\u00a5165,179<\/td><\/tr>\n        <tr><td>\u8282\u7701\u91d1\u989d<\/td><td style=\"color:var(--green);font-weight:700;\">-\u00a520,651<\/td><td style=\"color:var(--green);font-weight:700;\">-\u00a522,429<\/td><td style=\"color:var(--green);font-weight:700;\">-\u00a523,786<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- 6. \u7cfb\u7edf\u67b6\u6784\u5bf9\u6bd4 -->\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:16px;\">\ud83c\udfd7\ufe0f 6. \u7cfb\u7edf\u67b6\u6784\u5bf9\u6bd4<\/h3>\n    <div style=\"display:flex;gap:24px;flex-wrap:wrap;\">\n      <div style=\"flex:1;min-width:320px;\">\n        <h4 style=\"color:var(--orange);margin-bottom:12px;text-align:center;\">\u65b9\u6848\u4e00 \u00b7 \u53cc\u5916\u673a 220V\uff08\u5206\u533a\u72ec\u7acb\u63a7\u5236\uff09<\/h4>\n        <div style=\"text-align:center;padding:16px;background:#fff8f0;border-radius:10px;\">\n          <div class=\"arch-group\">\n            <div class=\"arch-box orange\">\u8212\u4eab\u5916\u673a 14kW<br>220V<\/div>\n            <span class=\"arch-arrow\">\u2192<\/span>\n            <div class=\"arch-box\">\u7cfb\u7edf\u4e00\u5185\u673a\u00d73<br>\u5ba2\u5385+\u4e66\u623f<\/div>\n          <\/div>\n          <div style=\"margin:8px 0;color:var(--text-light);font-size:13px;\">\u26a1 \u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c<\/div>\n          <div class=\"arch-group\">\n            <div class=\"arch-box orange\">\u5c0a\u777f\u5916\u673a 20kW<br>220V<\/div>\n            <span class=\"arch-arrow\">\u2192<\/span>\n            <div class=\"arch-box\">\u6c34\u6a21\u5757 22.4kW<\/div>\n            <span class=\"arch-arrow\">\u2192<\/span>\n            <div class=\"arch-box\">\u7cfb\u7edf\u4e8c\u5185\u673a\u00d75 + \u5730\u6696<\/div>\n          <\/div>\n          <div style=\"margin-top:8px;font-size:12px;color:var(--green);\">\u2713 \u65e0\u9700380V \u00b7 \u2713 \u5206\u533a\u63a7\u5236<\/div>\n        <\/div>\n      <\/div>\n      <div style=\"flex:1;min-width:320px;\">\n        <h4 style=\"color:var(--blue);margin-bottom:12px;text-align:center;\">\u65b9\u6848\u4e8c\/\u4e09 \u00b7 \u5355\u5916\u673a 380V\uff08\u96c6\u4e2d\u63a7\u5236\uff09<\/h4>\n        <div style=\"text-align:center;padding:16px;background:#eef2ff;border-radius:10px;\">\n          <div class=\"arch-group\">\n            <div class=\"arch-box\">\u5c0a\u777f\u5916\u673a<br>30kW\/33.5kW<br>380V 3N<\/div>\n          <\/div>\n          <div style=\"margin:4px 0;color:var(--text-light);font-size:18px;\">\u2193<\/div>\n          <div class=\"arch-group\">\n            <div class=\"arch-box\">\u6c34\u6a21\u5757<\/div>\n            <span class=\"arch-arrow\">\u2192<\/span>\n            <div class=\"arch-box\">\u5730\u6696 16\u56de\u8def<\/div>\n          <\/div>\n          <div style=\"margin:4px 0;color:var(--text-light);font-size:18px;\">\u2193<\/div>\n          <div class=\"arch-group\">\n            <div class=\"arch-box\">\u5185\u673a\u00d73+\u5185\u673a\u00d76<\/div>\n          <\/div>\n          <div style=\"margin-top:8px;font-size:12px;color:var(--blue);\">\u2713 \u5355\u5916\u673a\u7701\u7a7a\u95f4 \u00b7 \u2713 \u5168\u7ebf\u4e09\u7ba1\u5236 \u00b7 \u2717 \u9700380V<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n<\/div>\n<\/section>\n\n<!-- ========== sec-4 \u4e09\u65b9\u6848\u62a5\u4ef7\u6c47\u603b ========== -->\n<section class=\"sec\" id=\"sec-4\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u62a5\u4ef7\u6c47\u603b<\/div>\n  <h2 class=\"sec-title\">\u4e09\u65b9\u6848\u4f18\u60e0\u62a5\u4ef7\u6c47\u603b<\/h2>\n  <div class=\"note no\">\ud83d\udccc \u62a5\u4ef7\u8bf4\u660e\uff1a\u8bbe\u5907\u9762\u4ef7<strong>8\u6298<\/strong>\u4f18\u60e0\uff08\u6307\u4ee402\u4ea7\u54c1\u4ef7\u683c\u5e93\uff09\uff1b\u7ebf\u63a7\u5668\u6b63\u4ef7\u4e0d\u53c2\u4e0e\u6298\u6263\uff1b\u5b89\u88c5\u8d39\u660e\u7ec6\u89c1\u5404\u65b9\u6848\u62a5\u4ef7\u8868\uff1b\u5730\u6696\u6309\u00a5169\/\u33a1\u4f18\u60e0\u4ef7\uff08\u542b\u5206\u6c34\u5668\u53ca\u8f85\u6750\uff09\u3002<\/div>\n\n  <table class=\"tbl\" style=\"margin-bottom:24px;\">\n    <thead><tr>\n      <th>\u65b9\u6848<\/th>\n      <th>\u8bbe\u5907\u9762\u4ef7<\/th>\n      <th>\u8bbe\u59078\u6298<\/th>\n      <th>\u7ebf\u63a7\u5668<\/th>\n      <th>\u5b89\u88c5\u8d39<\/th>\n      <th>\u5730\u6696<\/th>\n      <th style=\"text-align:right;\">\u4f18\u60e0\u603b\u4ef7<\/th>\n    <\/tr><\/thead>\n    <tbody>\n      <tr>\n        <td><strong>\u65b9\u68481<\/strong><br>\u8212\u4eab+\u5c0a\u777f\u5168\u6548<\/td>\n        <td style=\"text-align:right;\">\u00a585,554<\/td>\n        <td style=\"text-align:right;color:#e67e22;\">\u00a568,442<\/td>\n        <td style=\"text-align:right;\">\u00a53,280<\/td>\n        <td style=\"text-align:right;\">\u00a515,525<\/td>\n        <td style=\"text-align:right;\">\u00a537,501<\/td>\n        <td style=\"text-align:right;font-size:20px;color:var(--orange);font-weight:700;\">\u00a5124,749<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u65b9\u68482<\/strong><br>VAM\u5c0a\u777f\u5168\u6548 30kW<\/td>\n        <td style=\"text-align:right;\">\u00a594,440<\/td>\n        <td style=\"text-align:right;color:#e67e22;\">\u00a575,551<\/td>\n        <td style=\"text-align:right;\">\u00a54,584<\/td>\n        <td style=\"text-align:right;\">\u00a518,325<\/td>\n        <td style=\"text-align:right;\">\u00a537,501<\/td>\n        <td style=\"text-align:right;font-size:20px;color:var(--orange);font-weight:700;\">\u00a5135,961<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u65b9\u68483<\/strong><br>VAM\u5c0a\u777f\u5168\u6548 33.5kW<\/td>\n        <td style=\"text-align:right;\">\u00a5101,229<\/td>\n        <td style=\"text-align:right;color:#e67e22;\">\u00a580,983<\/td>\n        <td style=\"text-align:right;\">\u00a54,584<\/td>\n        <td style=\"text-align:right;\">\u00a518,325<\/td>\n        <td style=\"text-align:right;\">\u00a537,501<\/td>\n        <td style=\"text-align:right;font-size:20px;color:var(--orange);font-weight:700;\">\u00a5141,393<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <!-- \u6c47\u603b\u5361\u7247 -->\n  <div style=\"display:flex;gap:16px;flex-wrap:wrap;margin-bottom:24px;\">\n      <div class=\"card\" style=\"flex:1;min-width:220px;text-align:center;padding:20px;\">\n        <h4 style=\"margin-bottom:8px;color:var(--orange);\">\u65b9\u68481 \u00b7 \u8212\u4eab+\u5c0a\u777f\u5168\u6548<\/h4>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:var(--text-light);margin:6px 0;\"><span>\u8bbe\u5907\u9762\u4ef7<\/span><span>\u00a585,554<\/span><\/div>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:#e67e22;margin:4px 0;\"><span>\u8bbe\u59078\u6298<\/span><span>\u00a568,442<\/span><\/div>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:var(--text-light);margin:4px 0;\"><span>\u7ebf\u63a7\u5668+\u5b89\u88c5+\u5730\u6696<\/span><span>\u00a53,280+\u00a515,525+\u00a537,501<\/span><\/div>\n        <hr style=\"border:none;border-top:1px dashed var(--border);margin:8px 0;\">\n        <p style=\"color:var(--text-light);font-size:13px;\">\u9762\u4ef7\u5408\u8ba1 \u00a5145,400<\/p>\n        <p class=\"price-tag\" style=\"margin:6px 0;\">\u00a5124,749<\/p>\n        <p style=\"color:var(--green);font-size:14px;\">\u6bd4\u9762\u4ef7\u7701 \u00a520,651<\/p>\n      <\/div>\n      <div class=\"card edge-b\" style=\"flex:1;min-width:220px;text-align:center;padding:20px;\">\n        <h4 style=\"margin-bottom:8px;color:var(--blue);\">\u65b9\u68482 \u00b7 VAM\u5c0a\u777f\u5168\u6548 30kW<\/h4>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:var(--text-light);margin:6px 0;\"><span>\u8bbe\u5907\u9762\u4ef7<\/span><span>\u00a594,440<\/span><\/div>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:#e67e22;margin:4px 0;\"><span>\u8bbe\u59078\u6298<\/span><span>\u00a575,551<\/span><\/div>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:var(--text-light);margin:4px 0;\"><span>\u7ebf\u63a7\u5668+\u5b89\u88c5+\u5730\u6696<\/span><span>\u00a54,584+\u00a518,325+\u00a537,501<\/span><\/div>\n        <hr style=\"border:none;border-top:1px dashed var(--border);margin:8px 0;\">\n        <p style=\"color:var(--text-light);font-size:13px;\">\u9762\u4ef7\u5408\u8ba1 \u00a5158,390<\/p>\n        <p class=\"price-tag\" style=\"margin:6px 0;\">\u00a5135,961<\/p>\n        <p style=\"color:var(--green);font-size:14px;\">\u6bd4\u9762\u4ef7\u7701 \u00a522,429<\/p>\n      <\/div>\n      <div class=\"card edge-g\" style=\"flex:1;min-width:220px;text-align:center;padding:20px;\">\n        <h4 style=\"margin-bottom:8px;color:var(--green);\">\u65b9\u68483 \u00b7 VAM\u5c0a\u777f\u5168\u6548 33.5kW<\/h4>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:var(--text-light);margin:6px 0;\"><span>\u8bbe\u5907\u9762\u4ef7<\/span><span>\u00a5101,229<\/span><\/div>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:#e67e22;margin:4px 0;\"><span>\u8bbe\u59078\u6298<\/span><span>\u00a580,983<\/span><\/div>\n        <div style=\"display:flex;justify-content:space-between;font-size:13px;color:var(--text-light);margin:4px 0;\"><span>\u7ebf\u63a7\u5668+\u5b89\u88c5+\u5730\u6696<\/span><span>\u00a54,584+\u00a518,325+\u00a537,501<\/span><\/div>\n        <hr style=\"border:none;border-top:1px dashed var(--border);margin:8px 0;\">\n        <p style=\"color:var(--text-light);font-size:13px;\">\u9762\u4ef7\u5408\u8ba1 \u00a5165,179<\/p>\n        <p class=\"price-tag\" style=\"margin:6px 0;\">\u00a5141,393<\/p>\n        <p style=\"color:var(--green);font-size:14px;\">\u6bd4\u9762\u4ef7\u7701 \u00a523,786<\/p>\n      <\/div>\n  <\/div>\n\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:8px;\">\ud83d\udcb0 \u4ef7\u683c\u8bf4\u660e<\/h3>\n    <p>\u2705 \u5305\u542b\uff1a\u65e5\u7acb\u539f\u5382\u8bbe\u5907\uff088\u6298\u4f18\u60e0\u4ef7\uff09+ \u7ebf\u63a7\u5668\uff08\u6b63\u4ef7\uff09+ \u5b89\u88c5\u8d39\uff08\u660e\u7ec6\u89c1\u5404\u65b9\u6848\uff09+ \u5730\u6696\u00a5169\/\u33a1\u4f18\u60e0\u5957\u9910\uff08\u542b\u5206\u6c34\u5668\u53ca\u8f85\u6750\uff09<\/p>\n    <p style=\"margin-top:6px;\">\u274c \u4e0d\u5305\u542b\uff1a380V\u7535\u529b\u589e\u5bb9\u3001\u540a\u9876\u5f00\u5b54\/\u68c0\u4fee\u53e3\u3001\u5730\u9762\u627e\u5e73\/\u56de\u586b\u3001\u5b9a\u5236\u98ce\u53e3<\/p>\n    <p style=\"margin-top:6px;color:var(--text-light);\">\u62a5\u4ef7\u6709\u6548\u671f30\u5929 | \u6700\u7ec8\u4f18\u60e0\u4ef7\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6<\/p>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-5 \u9009\u578b\u5efa\u8bae ========== -->\n<section class=\"sec\" id=\"sec-5\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u9009\u578b\u5efa\u8bae<\/div>\n  <h2 class=\"sec-title\">\u6211\u4eec\u7684\u4e00\u53e5\u5efa\u8bae<\/h2>\n  <div class=\"card edge-b\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\ud83d\udcca \u4e09\u65b9\u6848\u5bf9\u6bd4\u603b\u7ed3<\/h3>\n    <table class=\"tbl tbl-cmp\">\n      <thead><tr><th style=\"width:120px;\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00\uff08\u8212\u4eab+\u5c0a\u777f\uff09<\/th><th>\u65b9\u6848\u4e8c\uff08\u5c0a\u777f 30kW\uff09<\/th><th>\u65b9\u6848\u4e09\uff08\u5c0a\u777f 33.5kW\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u7535\u6e90\u8981\u6c42<\/td><td style=\"color:var(--green);\">220V \u65e0\u9700\u6539\u9020<\/td><td>380V \u9700\u7533\u8bf7<\/td><td>380V \u9700\u7533\u8bf7<\/td><\/tr>\n        <tr><td>\u5916\u673a\u5bb9\u91cf<\/td><td>14kW+20kW \u53cc\u5916\u673a<\/td><td>30kW<\/td><td style=\"color:var(--green);\">33.5kW<\/td><\/tr>\n        <tr><td>\u5185\u673a\u53f0\u6570<\/td><td>8\u53f0\uff083+5\uff09<\/td><td>9\u53f0\uff083+6\uff09<\/td><td>9\u53f0\uff083+6\uff09<\/td><\/tr>\n        <tr><td>\u8fde\u63a5\u7387<\/td><td style=\"color:var(--green);\">114.3%\/107.0% \u2713<\/td><td style=\"color:var(--green);\">128.7% \u2713<\/td><td style=\"color:var(--green);\">123.0% \u2713<\/td><\/tr>\n        <tr><td>APF\u80fd\u6548<\/td><td style=\"color:var(--green);\">5.45~5.8<\/td><td>5.2<\/td><td>5.2<\/td><\/tr>\n        <tr><td>\u566a\u97f3<\/td><td style=\"color:var(--green);\">53~55 dB(A)<\/td><td>56~58 dB(A)<\/td><td>58~60 dB(A)<\/td><\/tr>\n        <tr><td>\u8bbe\u59078\u6298\u540e<\/td><td style=\"color:#e67e22;\">\u00a568,442<\/td><td style=\"color:#e67e22;\">\u00a575,551<\/td><td style=\"color:#e67e22;\">\u00a580,983<\/td><\/tr>\n        <tr><td>\u4f18\u60e0\u603b\u4ef7<\/td><td style=\"color:var(--green);font-weight:700;\">\u00a5124,749<\/td><td>\u00a5135,961<\/td><td>\u00a5141,393<\/td><\/tr>\n        <tr><td>\u9002\u5408\u573a\u666f<\/td><td>\u9884\u7b97\u6709\u9650\/\u65e0380V<\/td><td>\u5168\u5f00\u7387\u9ad8\/\u6027\u4ef7\u6bd4<\/td><td>\u5168\u5f00\u6781\u9ad8\/\u6781\u81f4\u8212\u9002<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:12px;\">\u2705 \u63a8\u8350\u5efa\u8bae<\/h3>\n    <p><strong>\u5982\u60a8\u5bb6\u6682\u65e0380V<\/strong>\uff1a\u9009<strong>\u65b9\u6848\u4e00\uff08\u8212\u4eab+\u5c0a\u777f\u5168\u6548\uff09<\/strong>\uff0c220V\u53cc\u5916\u673a\uff0c\u4f18\u60e0\u603b\u4ef7\u00a5124,749\u3002\u5367\u5ba4\u533a\u57df\u5df2\u7528\u5c0a\u777f\u5168\u6548\uff0c\u8212\u9002\u6709\u4fdd\u969c\u3002<\/p>\n    <p style=\"margin-top:10px;\"><strong>\u5982\u5df2\u7533\u8bf7380V<\/strong>\uff1a\u53ef\u9009<strong>\u65b9\u6848\u4e8c\uff0830kW\uff09<\/strong>\uff08\u4f18\u60e0\u603b\u4ef7\u00a5135,961\uff09\u6216<strong>\u65b9\u6848\u4e09\uff0833.5kW\uff09<\/strong>\uff08\u00a5141,393\uff09\u3002\u4e24\u65b9\u6848\u8fde\u63a5\u7387\u5747\u5b89\u5168\uff08128.7%\/123.0%\uff09\u3002\u65b9\u6848\u4e8c\u6027\u4ef7\u6bd4\u66f4\u9ad8\uff0c\u65b9\u6848\u4e09\u5168\u5f00\u5197\u4f59\u66f4\u8db3\u3002\u5dee\u4ef7\u4ec5\u00a55,432\uff0c\u5982\u9884\u7b97\u5145\u88d5\u5efa\u8bae\u9009\u65b9\u6848\u4e09\u3002<\/p>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-6 \u5b89\u88c5\u4fdd\u969c ========== -->\n<section class=\"sec\" id=\"sec-6\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u5b89\u88c5\u4fdd\u969c<\/div>\n  <h2 class=\"sec-title\">\u5b89\u88c5\u4e0e\u670d\u52a1\u4fdd\u969c<\/h2>\n  <div class=\"card\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\ud83c\udfd7\ufe0f \u9f99\u8109\u6696\u901a\u6807\u51c6\u65bd\u5de5\u5de5\u827a<\/h3>\n    <table class=\"tbl\">\n      <thead><tr><th>\u65bd\u5de5\u9636\u6bb5<\/th><th>\u6807\u51c6\u5de5\u827a<\/th><th>\u8d28\u91cf\u4fdd\u969c<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5b9a\u4f4d\u653e\u7ebf<\/td><td>\u6fc0\u5149\u5b9a\u4f4d\uff0c\u7cbe\u51c6\u6807\u6ce8<\/td><td>\u62cd\u7167\u5b58\u6863<\/td><\/tr>\n        <tr><td>\u7ba1\u8def\u94fa\u8bbe<\/td><td>\u5145\u6c2e\u710a\u63a5\uff0c\u65e0\u6c27\u5316\u53cd\u5e94<\/td><td>24h\u4fdd\u538b\u6d4b\u8bd5<\/td><\/tr>\n        <tr><td>\u5730\u6696\u76d8\u7ba1<\/td><td>PE-RT\u963b\u6c27\u7ba1\uff0c\u95f4\u8ddd\u6309\u8bbe\u8ba1<\/td><td>6bar\u6c34\u538b\u8bd5\u9a8c<\/td><\/tr>\n        <tr><td>\u8bbe\u5907\u8c03\u8bd5<\/td><td>\u5168\u7cfb\u7edf\u8054\u52a8\u8c03\u8bd5<\/td><td>\u51fa\u5177\u8c03\u8bd5\u62a5\u544a<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:12px;\">\ud83d\udee1\ufe0f 10\u5e74\u54c1\u8d28\u4fdd\u969c<\/h3>\n    <p>\u9f99\u8109\u6696\u901a\u6210\u7acb\u4e8e2004\u5e74\uff0c20\u5e74\u6696\u901a\u884c\u4e1a\u7ecf\u9a8c\u3002\u6210\u90fd1000+\u5bb6\u5ead\u7684\u9009\u62e9\uff0c\u53e3\u7891\u89c1\u8bc1\u5b9e\u529b\u3002<\/p>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-7 \u4e0b\u4e00\u6b65 ========== -->\n<section class=\"sec\" id=\"sec-7\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u4e0b\u4e00\u6b65\u884c\u52a8<\/div>\n  <h2 class=\"sec-title\">\u60a8\u7684\u4e0b\u4e00\u6b65<\/h2>\n  <div class=\"note nb\">\ud83d\udcde \u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7 \ud83d\udcde 15828489188<\/div>\n  <table class=\"tbl\">\n    <thead><tr><th>\u6b65\u9aa4<\/th><th>\u884c\u52a8\u5185\u5bb9<\/th><th>\u9884\u8ba1\u65f6\u95f4<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td><strong>P0<\/strong><\/td><td>\u786e\u8ba4\u65b9\u6848\u9009\u62e9\uff08\u4e00\/\u4e8c\/\u4e09\uff09\uff0c\u9884\u7ea6\u73b0\u573a\u590d\u6d4b<\/td><td>1\u5929\u5185<\/td><\/tr>\n      <tr><td><strong>P1<\/strong><\/td><td>\u7b7e\u8ba2\u6b63\u5f0f\u5408\u540c\uff0c\u652f\u4ed8\u5b9a\u91d1\uff0c\u9501\u5b9a\u8bbe\u5907\u53ca\u4f18\u60e0<\/td><td>3~5\u5929<\/td><\/tr>\n      <tr><td><strong>P2<\/strong><\/td><td>\u5b89\u6392\u8fdb\u573a\u65bd\u5de5\uff0c\u5168\u7a0b\u8282\u70b9\u9a8c\u6536<\/td><td>\u534f\u5546\u6392\u671f<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"card\" style=\"margin-top:24px;text-align:center;\">\n    <h3 style=\"color:var(--orange);margin-bottom:12px;\">\u671f\u5f85\u4e3a\u60a8\u670d\u52a1\uff01<\/h3>\n    <p>\u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 \ud83d\udcde 15828489188<\/p>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-heat ========== -->\n<section class=\"sec\" id=\"sec-heat\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u5730\u6696\u914d\u7f6e<\/div>\n  <h2 class=\"sec-title\">\u4e09\u65b9\u6848\u5730\u6696\u914d\u7f6e\u8be6\u60c5<\/h2>\n  <div class=\"note nb\">\u4e09\u65b9\u6848\u5730\u6696\u9762\u79ef\u7edf\u4e00\u4e3a221.90\u33a1\uff0c\u914d\u7f6ePE-RT\u963b\u6c27\u5730\u6696\u7ba1\uff0c16\u56de\u8def\u5206\u6c34\u5668\u5206\u914d\u3002\u4f18\u60e0\u5355\u4ef7\u00a5169\/\u33a1\u3002<\/div>\n  <div class=\"card edge-g\">\n    <h4 style=\"color:var(--green);margin-bottom:8px;\">\u5730\u6696\u7cfb\u7edf\u6280\u672f\u8bf4\u660e<\/h4>\n    <ul style=\"padding-left:20px;line-height:2;\">\n      <li>\u5730\u6696\u7ba1\uff1aPE-RT\u963b\u6c27\u7ba1 dn20\u00d7en2.0<\/li>\n      <li>\u76d8\u7ba1\u95f4\u8ddd\uff1a175mm<\/li>\n      <li>\u5206\u6c34\u5668\uff1a3\u7ec4\uff084+6+6\u56de\u8def\uff09<\/li>\n      <li>\u6c34\u6a21\u5757\uff1a\u8865\u6c14\u589e\u7113\u5f0f\uff0c\uff0d25\u2103\u6b63\u5e38\u5236\u70ed<\/li>\n      <li>\u63a7\u5236\uff1a\u6bcf\u56de\u8def\u72ec\u7acb\u6e29\u63a7<\/li>\n      <li>\u4f18\u60e0\u4ef7\uff1a\u00a5169\/\u33a1\uff08\u542b\u5206\u6c34\u5668\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u8f85\u6750\uff09<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-cases ========== -->\n<section class=\"sec\" id=\"sec-cases\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u5ba2\u6237\u6848\u4f8b<\/div>\n  <h2 class=\"sec-title\">\u9f99\u8109\u6696\u901a \u00b7 \u540c\u7c7b\u9879\u76ee\u6848\u4f8b<\/h2>\n  <div class=\"note nb\">\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u5728\u6210\u90fd\u540c\u7c7b\u8054\u6392\u522b\u5885\u9879\u76ee\u4e2d\u7684\u65e5\u7acb\u4e24\u8054\u4f9b\u7cfb\u7edf\u65bd\u5de5\u6848\u4f8b\u3002<\/div>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(300px,1fr));gap:20px;margin:20px 0;\">\n    <div class=\"card edge-b\"><h4 style=\"color:var(--blue);\">\u4fdd\u5229\u5929\u73ba<\/h4><p>\u65e5\u7acbVAM\u5c0a\u777f\u5168\u6548\uff0c\u7a7a\u8c03215\u33a1\uff0c\u5730\u6696198\u33a1\uff0c380V\u3002<\/p><\/div>\n    <div class=\"card\"><h4 style=\"color:var(--orange);\">\u6052\u5927\u5c71\u6c34\u57ce<\/h4><p>\u65e5\u7acb\u8212\u4eab+\u5c0a\u777f\uff0c\u7a7a\u8c03188\u33a1\uff0c\u5730\u6696205\u33a1\uff0c220V\u3002<\/p><\/div>\n    <div class=\"card edge-g\"><h4 style=\"color:var(--green);\">\u6606\u4ed1\u5fa1<\/h4><p>\u65e5\u7acbVAM\u5c0a\u777f\u5168\u6548\uff0c\u7a7a\u8c03165\u33a1\uff0c\u5730\u6696180\u33a1\uff0c380V\u3002<\/p><\/div>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-materials ========== -->\n<section class=\"sec\" id=\"sec-materials\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u8f85\u6750\u6e05\u5355<\/div>\n  <h2 class=\"sec-title\">\u8f85\u6750\u53ca\u65bd\u5de5\u6807\u51c6<\/h2>\n  <h4 style=\"margin:16px 0 8px;color:var(--blue);\">\u7a7a\u8c03\u8f85\u6750<\/h4>\n  <table class=\"tbl\">\n    <thead><tr><th>\u6750\u6599<\/th><th>\u54c1\u724c<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u94dc\u7ba1<\/td><td>\u6d77\u4eae\/\u4e2d\u4f73<\/td><td>\u03c66.35~\u03c628.58<\/td><\/tr>\n      <tr><td>\u4fdd\u6e29<\/td><td>\u534e\u7f8e<\/td><td>\u5bf9\u5e94\u94dc\u7ba1\u89c4\u683c<\/td><\/tr>\n      <tr><td>\u51b7\u51dd\u6c34\u7ba1<\/td><td>\u8054\u5851PVC-U<\/td><td>DN25\/DN32<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <h4 style=\"margin:16px 0 8px;color:var(--green);\">\u5730\u6696\u8f85\u6750<\/h4>\n  <table class=\"tbl\">\n    <thead><tr><th>\u6750\u6599<\/th><th>\u54c1\u724c<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u5730\u6696\u7ba1<\/td><td>PE-RT\u963b\u6c27\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><\/tr>\n      <tr><td>\u5206\u6c34\u5668<\/td><td>\u65e5\u7acb\/\u4e39\u5f17\u65af<\/td><td>3\u7ec4<\/td><\/tr>\n      <tr><td>\u4fdd\u6e29\u677f<\/td><td>\u767d\u6676\u677f<\/td><td>20mm<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n<\/section>\n\n<!-- ========== sec-member ========== -->\n<section class=\"sec\" id=\"sec-member\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u4f1a\u5458\u6743\u76ca<\/div>\n  <h2 class=\"sec-title\">VIP\u4f1a\u5458\u6743\u76ca<\/h2>\n  <table class=\"tbl\">\n    <thead><tr><th>\u6743\u76ca<\/th><th>\u6807\u51c6<\/th><th style=\"color:var(--orange);\">VIP<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u8d28\u4fdd<\/td><td>\u5382\u5bb6\u6807\u51c6<\/td><td style=\"color:var(--orange);\">\u5382\u5bb6+\u9f99\u8109\u5ef6\u4fdd1\u5e74<\/td><\/tr>\n      <tr><td>\u65bd\u5de5\u8d28\u4fdd<\/td><td>1\u5e74<\/td><td style=\"color:var(--orange);\">3\u5e74\uff0c\u6bcf\u5e74\u514d\u8d39\u68c0\u6d4b<\/td><\/tr>\n      <tr><td>\u5e94\u6025\u54cd\u5e94<\/td><td>24h<\/td><td style=\"color:var(--orange);\">12h\u4e0a\u95e8<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n<\/section>\n\n<!-- ========== sec-brand ========== -->\n<section class=\"sec\" id=\"sec-brand\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u54c1\u724c\u4ecb\u7ecd<\/div>\n  <h2 class=\"sec-title\">\u65e5\u7acb \u00d7 \u9f99\u8109\u6696\u901a<\/h2>\n  <div class=\"card edge-b\">\n    <h3 style=\"color:var(--blue);margin-bottom:12px;\">\ud83c\udfed \u65e5\u7acb\uff08HITACHI\uff09<\/h3>\n    <p>\u521b\u7acb\u4e8e1910\u5e74\uff0c\u5168\u7403500\u5f3a\u30021983\u5e74\u63a8\u51fa\u5168\u7403\u9996\u6b3e\u53d8\u9891\u591a\u8054\u673a\u3002\u6838\u5fc3\u4ea7\u54c1\uff1aEX\u8212\u4eab\uff08\u5165\u95e8\u9ad8\u6548\uff09\u3001VAM\u5c0a\u777f\u5168\u6548\uff08\u65d7\u8230\u4e09\u7ba1\u5236\u51c0\u5316\uff09\u3002<\/p>\n  <\/div>\n  <div class=\"card edge-g\">\n    <h3 style=\"color:var(--green);margin-bottom:12px;\">\ud83c\udfe2 \u6210\u90fd\u9f99\u8109\u6696\u901a<\/h3>\n    <p>2004\u5e74\u6210\u7acb\uff0c20\u5e74\u6df1\u8015\u3002\u65e5\u7acb\u6388\u6743\u7ecf\u9500\u5546\uff0c\u6210\u90fd1000+\u5bb6\u5ead\u9009\u62e9\u3002\u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 15828489188\u3002<\/p>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-ai ========== -->\n<section class=\"sec\" id=\"sec-ai\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">AI\u9a8c\u8bc1<\/div>\n  <h2 class=\"sec-title\">\u65b9\u6848AI\u4ea4\u53c9\u9a8c\u8bc1<\/h2>\n  <div class=\"card\"><p><strong>Q1\uff1a\u65b9\u6848\u4e00\u53cc\u5916\u673a\u8fde\u63a5\u7387114.3%\/107.0%\u662f\u5426\u504f\u9ad8\uff1f<\/strong><\/p><p>A\uff1a114%\u5728\u65e5\u7acbSET-FREE\u7cfb\u5217\u5141\u8bb8\u8303\u56f4\u5185\uff08\u6700\u9ad8130%\uff09\uff0c\u4e14\u7a7a\u8c03\u5f88\u5c11\u5168\u5f00\uff0c\u5b8c\u5168\u5b89\u5168\u3002<\/p><\/div>\n  <div class=\"card\"><p><strong>Q2\uff1a\u65b9\u6848\u4e8c\u8fde\u63a5\u7387128.7%\u662f\u5426\u5408\u7406\uff1f<\/strong><\/p><p>A\uff1a128.7%\u5728\u65e5\u7acbSET-FREE\u7cfb\u5217\u63a8\u8350\u8303\u56f4\uff08100%~130%\uff09\u5185\uff0c\u914d\u7f6e\u5408\u7406\uff0c7\u5ba4\u5168\u5f00\u5236\u51b7\u6548\u679c\u6709\u4fdd\u969c\u3002<\/p><\/div>\n  <div class=\"card\"><p><strong>Q3\uff1a\u65b9\u6848\u4e8c\/\u4e09\u7684380V\u7533\u8bf7\u5468\u671f\uff1f\u8d39\u7528\uff1f<\/strong><\/p><p>A\uff1a\u6210\u90fd\u7ea615~30\u5929\uff0c\u7535\u8868\u514d\u8d39\uff0c\u5165\u6237\u7535\u7f06\u7ea63,000~8,000\u5143\u3002<\/p><\/div>\n<\/div>\n<\/section>\n\n<!-- ========== sec-terms ========== -->\n<section class=\"sec\" id=\"sec-terms\">\n<div class=\"wrap\">\n  <div class=\"sec-label\">\u9644\u6ce8\u6761\u6b3e<\/div>\n  <h2 class=\"sec-title\">\u62a5\u4ef7\u9644\u6ce8\u4e0e\u6761\u6b3e<\/h2>\n  <div class=\"card\">\n    <ol style=\"padding-left:20px;line-height:2;\">\n      <li>\u672c\u62a5\u4ef7\u4e3a\u8bbe\u5907+\u6750\u6599+\u65bd\u5de5+\u8c03\u8bd5\u5168\u5305\u4ef7\uff0c\u65e0\u9690\u5f62\u8d39\u7528\u3002<\/li>\n      <li>\u62a5\u4ef7\u6709\u6548\u671f30\u5929\u3002<\/li>\n      <li>\u6700\u7ec8\u4f18\u60e0\u4ef7\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\u3002<\/li>\n      <li>380V\u7535\u529b\u589e\u5bb9\u8d39\u7528\u53e6\u884c\u62a5\u4ef7\u3002<\/li>\n    <\/ol>\n  <\/div>\n  <div class=\"card edge-g\">\n    <h4 style=\"color:var(--green);margin-bottom:8px;\">\u8d28\u4fdd\u6761\u6b3e<\/h4>\n    <ul style=\"padding-left:20px;line-height:2;\">\n      <li>\u65e5\u7acb\u5382\u5bb6\u6574\u673a\u8d28\u4fdd\uff1a6\u5e74<\/li>\n      <li>\u9f99\u8109\u65bd\u5de5\u8d28\u4fdd\uff1a3\u5e74<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n<\/section>\n\n<footer class=\"footer\">\n  <div class=\"wrap\">\n    <div class=\"footer-motto\">\u4e13\u4e1a \u00b7 \u900f\u660e \u00b7 \u7701\u5fc3 \u00b7 \u957f\u6548<\/div>\n    <div>\u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 \ud83d\udcde 15828489188<\/div>\n    <div class=\"footer-copy\">\u00a9 2004 \u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8<\/div>\n  <\/div>\n<\/footer>\n\n<script>\nfunction switchTab(tabId, btn) {\n  var panes = btn.closest('.sec').querySelectorAll('.tab-pane');\n  panes.forEach(function(p) { p.classList.remove('active'); });\n  document.getElementById(tabId).classList.add('active');\n  var parent = btn.parentElement;\n  if (parent) {\n    parent.querySelectorAll('.comp-tab').forEach(function(t) { t.classList.remove('active'); });\n  }\n  btn.classList.add('active');\n}\nfunction switchCat(idx) {\n  document.querySelectorAll('.cat-btn').forEach(function(b, i) { b.classList.toggle('active', i === idx); });\n  document.querySelectorAll('.bc-group').forEach(function(g) { g.hidden = true; });\n  var bc = document.getElementById('bc-' + idx);\n  if (bc) bc.hidden = false;\n  var firstSec = ['sec-1','sec-2','sec-3','sec-compare','sec-6','sec-7'][idx];\n  showSection(firstSec);\n}\nfunction showSection(secId) {\n  document.querySelectorAll('.sec').forEach(function(s) { s.classList.remove('active'); });\n  var target = document.getElementById(secId);\n  if (target) target.classList.add('active');\n  target && target.scrollIntoView({behavior:'smooth'});\n}\nwindow.addEventListener('DOMContentLoaded', function() {\n  document.getElementById('sec-1').classList.add('active');\n});\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 \ud83d\udcde 15828 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-5609","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=5609\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a \u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 \ud83d\udcde 15828 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=5609\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-07T06:07:07+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5609\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5609\",\"name\":\"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-07-07T06:02:25+00:00\",\"dateModified\":\"2026-07-07T06:07:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5609#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5609\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5609#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=5609","og_locale":"zh_CN","og_type":"article","og_title":"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a \u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7 \ud83d\udcde 15828 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=5609","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-07T06:07:07+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"11 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=5609","url":"https:\/\/longmai-nt.com\/?page_id=5609","name":"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-07-07T06:02:25+00:00","dateModified":"2026-07-07T06:07:07+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=5609#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=5609"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=5609#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9648\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u4e91\u9526\u5c0a\u777f\u5168\u6548\u591a\u65b9\u6848\u5bf9\u6bd4\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5609","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5609"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5609\/revisions"}],"predecessor-version":[{"id":5612,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5609\/revisions\/5612"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}