{"id":5970,"date":"2026-07-09T17:28:16","date_gmt":"2026-07-09T09:28:16","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=5970"},"modified":"2026-07-09T17:28:17","modified_gmt":"2026-07-09T09:28:17","slug":"%e6%9d%a8%e5%a5%b3%e5%a3%ab-%c2%b7-%e7%91%9e%e4%ba%91%e5%a3%b9%e5%8f%b7%e6%9d%91%e5%ba%84%e6%97%a5%e7%ab%8b%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%8f%8c%e6%96%b9%e6%a1%88%e5%af%b9%e6%af%94","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=5970","title":{"rendered":"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4"},"content":{"rendered":"\n\n  \n  \n  \n  <style>\n    :root {\n      --primary: #1a5f7a;\n      --primary-light: #e8f4f8;\n      --primary-dark: #0d3d50;\n      --accent: #c0392b;\n      --accent-light: #fdeaea;\n      --green: #27ae60;\n      --green-light: #e8f7ef;\n      --orange: #e67e22;\n      --orange-light: #fef4e8;\n      --yellow-light: #fff9e6;\n      --bg: #f5f7fa;\n      --card-bg: #ffffff;\n      --text: #222;\n      --text-secondary: #555;\n      --text-muted: #888;\n      --border: #e0e0e0;\n      --radius: 10px;\n      --shadow: 0 2px 10px rgba(0,0,0,0.06);\n      --shadow-hover: 0 4px 20px rgba(0,0,0,0.10);\n    }\n    * { box-sizing: border-box; }\n    body {\n      font-family: \"PingFang SC\", \"Microsoft YaHei\", \"Helvetica Neue\", Arial, sans-serif;\n      background: var(--bg);\n      color: var(--text);\n      line-height: 1.7;\n      margin: 0;\n      padding: 0;\n    }\n    \/* === Header === *\/\n    header {\n      background: linear-gradient(135deg, var(--primary) 0%, #2c8da8 100%);\n      color: white;\n      padding: 50px 20px 40px;\n      text-align: center;\n    }\n    header h1 { margin: 0 0 10px; font-size: 2em; font-weight: 700; }\n    header .subtitle { margin: 0; font-size: 1.05em; opacity: 0.90; }\n    header .tags-line { margin-top: 12px; }\n    header .tag-white {\n      display: inline-block;\n      background: rgba(255,255,255,0.18);\n      color: white;\n      padding: 4px 14px;\n      border-radius: 20px;\n      font-size: 0.85em;\n      margin: 3px 5px;\n    }\n    \/* === Container === *\/\n    .container { max-width: 1100px; margin: 0 auto; padding: 30px 20px; }\n    \/* === TOC === *\/\n    nav.toc {\n      background: var(--card-bg);\n      border-radius: var(--radius);\n      box-shadow: var(--shadow);\n      padding: 22px 28px;\n      margin-bottom: 28px;\n    }\n    nav.toc h3 { margin: 0 0 14px; color: var(--primary); font-size: 1.2em; }\n    nav.toc .toc-grid {\n      display: grid;\n      grid-template-columns: repeat(auto-fill, minmax(200px, 1fr));\n      gap: 8px;\n    }\n    nav.toc .toc-grid a {\n      color: var(--text);\n      text-decoration: none;\n      padding: 6px 10px;\n      border-radius: 6px;\n      transition: background 0.2s;\n      font-size: 0.95em;\n    }\n    nav.toc .toc-grid a:hover { background: var(--primary-light); color: var(--primary); }\n    \/* === Section & Card === *\/\n    section { margin-bottom: 30px; }\n    .card {\n      background: var(--card-bg);\n      border-radius: var(--radius);\n      box-shadow: var(--shadow);\n      padding: 28px 30px;\n      margin-bottom: 22px;\n    }\n    .card h2 {\n      margin: 0 0 18px;\n      font-size: 1.45em;\n      color: var(--primary);\n      border-bottom: 2px solid var(--primary-light);\n      padding-bottom: 12px;\n    }\n    .card h3 { margin: 22px 0 12px; color: var(--text); font-size: 1.1em; }\n    .card h4 { margin: 15px 0 8px; font-size: 1em; }\n    \/* === \u5ba2\u6237\u6210\u529f\u76ee\u6807 \u4fe1\u606f\u5361 === *\/\n    .info-grid {\n      display: grid;\n      grid-template-columns: repeat(auto-fill, minmax(160px, 1fr));\n      gap: 12px;\n      margin: 16px 0;\n    }\n    .info-item {\n      background: var(--primary-light);\n      border-radius: 8px;\n      padding: 12px 14px;\n    }\n    .info-item .label { font-size: 0.8em; color: var(--text-secondary); margin-bottom: 3px; }\n    .info-item .value { font-size: 1.05em; font-weight: 600; color: var(--primary); }\n    \/* === Tags === *\/\n    .tag {\n      display: inline-block;\n      padding: 2px 10px;\n      border-radius: 20px;\n      font-size: 0.78em;\n      font-weight: 600;\n      margin-right: 5px;\n    }\n    .tag-primary { background: var(--primary-light); color: var(--primary); }\n    .tag-green { background: var(--green-light); color: var(--green); }\n    .tag-orange { background: var(--orange-light); color: var(--orange); }\n    .tag-red { background: var(--accent-light); color: var(--accent); }\n    .tag-star { background: var(--yellow-light); color: #d4a017; }\n    .tag-biaopei { background: #e8f4fd; color: #2980b9; }\n    .tag-xuanpei { background: #fef0e8; color: #e67e22; }\n    .tag-hexin { background: #fde8e8; color: #c0392b; }\n    \/* === Plan badges === *\/\n    .plan-badge {\n      display: inline-block;\n      padding: 3px 14px;\n      border-radius: 20px;\n      font-weight: 600;\n      font-size: 0.88em;\n    }\n    .plan-a { background: var(--primary-light); color: var(--primary); }\n    .plan-b { background: var(--orange-light); color: var(--orange); }\n    \/* === Tables === *\/\n    table {\n      width: 100%;\n      border-collapse: collapse;\n      margin: 14px 0;\n      font-size: 0.93em;\n    }\n    th, td {\n      border: 1px solid var(--border);\n      padding: 9px 11px;\n      text-align: left;\n    }\n    th { background: #f5f8fa; font-weight: 600; }\n    tr:nth-child(even) { background: #fafafa; }\n    .comparison-table th { background: var(--primary); color: white; }\n    .text-center { text-align: center; }\n    \/* === \u9700\u6c42\u6838\u5bf9\u8868 === *\/\n    .checklist { margin: 16px 0; }\n    .checklist tr td:last-child { text-align: center; font-weight: 700; color: var(--green); }\n    .checklist th { background: var(--primary); color: white; }\n    \/* === \u914d\u7f6e\u901f\u89c8 === *\/\n    .config-cards {\n      display: grid;\n      grid-template-columns: repeat(auto-fill, minmax(200px, 1fr));\n      gap: 14px;\n      margin: 16px 0;\n    }\n    .config-card {\n      background: #f8fafb;\n      border-radius: 8px;\n      padding: 16px;\n      border: 1px solid var(--border);\n    }\n    .config-card .room { font-weight: 600; color: var(--primary); margin-bottom: 4px; }\n    .config-card .area { font-size: 0.85em; color: var(--text-secondary); }\n    .config-card .unit { font-size: 1.1em; font-weight: 600; margin-top: 6px; }\n    .config-card .tag { margin-top: 6px; }\n    \/* === \u6838\u5fc3\u7279\u6027 === *\/\n    .feature-grid {\n      display: grid;\n      grid-template-columns: repeat(auto-fill, minmax(280px, 1fr));\n      gap: 14px;\n      margin: 16px 0;\n    }\n    .feature-card {\n      background: #f8fafb;\n      border-radius: 8px;\n      padding: 18px;\n      border: 1px solid var(--border);\n    }\n    .feature-card h4 { margin: 0 0 8px; font-size: 1em; }\n    .feature-card p { margin: 0; font-size: 0.9em; color: var(--text-secondary); }\n    \/* === \u62a5\u4ef7 === *\/\n    .price-grid {\n      display: grid;\n      grid-template-columns: repeat(auto-fill, minmax(280px, 1fr));\n      gap: 18px;\n      margin: 16px 0;\n    }\n    .price-card {\n      border: 2px solid var(--border);\n      border-radius: var(--radius);\n      padding: 22px;\n      transition: box-shadow 0.2s;\n    }\n    .price-card:hover { box-shadow: var(--shadow-hover); }\n    .price-card.selected { border-color: var(--primary); background: #fafcfd; }\n    .price-card .price-title { font-weight: 600; font-size: 1em; margin-bottom: 12px; }\n    .price-card .price-amount { font-size: 1.6em; font-weight: 700; color: var(--primary); margin: 8px 0; }\n    .price-card .price-note { font-size: 0.85em; color: var(--text-secondary); }\n    .price-row { display: flex; justify-content: space-between; padding: 6px 0; border-bottom: 1px dashed var(--border); font-size: 0.9em; }\n    .price-row.total { font-weight: 700; font-size: 1em; border-top: 2px solid var(--border); border-bottom: none; margin-top: 8px; padding-top: 10px; color: var(--primary); }\n    \/* === \u4f18\u60e0\u8bf4\u660e === *\/\n    .discount-box {\n      background: var(--yellow-light);\n      border-left: 4px solid #d4a017;\n      padding: 16px 20px;\n      border-radius: 6px;\n      margin: 16px 0;\n    }\n    .discount-box li { margin: 6px 0; }\n    \/* === \u7cbe\u5de5\u516d\u6b65 === *\/\n    .steps-grid {\n      display: grid;\n      grid-template-columns: repeat(auto-fill, minmax(230px, 1fr));\n      gap: 14px;\n      margin: 16px 0;\n    }\n    .step {\n      background: #f8fafb;\n      border-radius: 8px;\n      padding: 16px;\n      border-left: 4px solid var(--primary);\n    }\n    .step .num { font-size: 1.4em; font-weight: 700; color: var(--primary); margin-bottom: 6px; }\n    .step h4 { margin: 0 0 6px; }\n    .step p { margin: 0; font-size: 0.9em; color: var(--text-secondary); }\n    \/* === \u6848\u4f8b === *\/\n    .case-list { margin: 14px 0; }\n    .case-item { padding: 10px 0; border-bottom: 1px dashed var(--border); }\n    .case-item:last-child { border-bottom: none; }\n    .case-item a { color: var(--primary); text-decoration: none; font-weight: 500; }\n    .case-item a:hover { text-decoration: underline; }\n    .case-item .desc { font-size: 0.9em; color: var(--text-secondary); margin-top: 2px; }\n    \/* === FAQ === *\/\n    .faq-item { margin: 16px 0; }\n    .faq-item h4 { margin: 0 0 6px; color: var(--primary); }\n    .faq-item p { margin: 0; font-size: 0.93em; }\n    \/* === Recommend === *\/\n    .recommend-box {\n      background: var(--green-light);\n      border-left: 4px solid var(--green);\n      padding: 18px 20px;\n      border-radius: 8px;\n      margin: 20px 0;\n    }\n    .recommend-box h4 { margin: 0 0 8px; color: var(--green); }\n    .recommend-box p { margin: 4px 0; font-size: 0.95em; }\n    .warning-box {\n      background: var(--accent-light);\n      border-left: 4px solid var(--accent);\n      padding: 14px 18px;\n      border-radius: 8px;\n      margin: 16px 0;\n      font-size: 0.92em;\n    }\n    .note { font-size: 0.87em; color: var(--text-muted); margin-top: 6px; }\n    .highlight { background: var(--yellow-light); padding: 2px 6px; border-radius: 4px; font-weight: 600; }\n    \/* === Footer === *\/\n    footer {\n      background: #222;\n      color: #ccc;\n      text-align: center;\n      padding: 30px 20px;\n      margin-top: 40px;\n    }\n    footer p { margin: 5px 0; font-size: 0.93em; }\n    footer .tel { color: white; font-size: 1.1em; font-weight: 600; }\n    footer .store { color: #aaa; }\n    hr { border: none; border-top: 1px solid var(--border); margin: 24px 0; }\n    @media (max-width: 768px) {\n      header h1 { font-size: 1.5em; }\n      .info-grid { grid-template-columns: 1fr 1fr; }\n      .config-cards { grid-template-columns: 1fr 1fr; }\n      .price-grid { grid-template-columns: 1fr; }\n      .feature-grid { grid-template-columns: 1fr; }\n    }\n  <\/style>\n\n<header>\n  <h1>\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4<\/h1>\n  <p class=\"subtitle\">\u6210\u90fd\u00b7\u745e\u4e91\u58f9\u53f7\u6751\u5e84\u00b72\u5c42\u522b\u5885\u00b7\u5e38\u4f4f6\u4eba | \u65b9\u6848\u4e00\uff1aRAS-224HRNBQ\u4e00\u62d6\u4e03 \u5bf9\u6bd4 \u65b9\u6848\u4e8c\uff1aRAS-100HRNAQ+RAS-160HRNAQ\u5206\u5c42\u4e24\u5957<\/p>\n  <div class=\"tags-line\">\n    <span class=\"tag-white\">\ud83c\udfe0 142.5\u33a1<\/span>\n    <span class=\"tag-white\">\ud83d\udc68\u200d\ud83d\udc69\u200d\ud83d\udc67\u200d\ud83d\udc66 \u5e38\u4f4f6\u4eba<\/span>\n    <span class=\"tag-white\">\u2744\ufe0f \u5236\u51b7\u4e3a\u4e3b<\/span>\n    <span class=\"tag-white\">\ud83d\udd04 1-2\u5c42\u540c\u65f6\u4f7f\u7528<\/span>\n  <\/div>\n  <p style=\"margin-top:14px;font-size:0.9em;opacity:0.85;\">\ud83d\udcd6 <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" style=\"color:white;text-decoration:underline;\">\u67e5\u770b\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\u624b\u518c \u2192<\/a><\/p>\n<\/header>\n\n<div class=\"container\">\n\n  <!-- ==================== \u65b9\u6848\u76ee\u5f55 ==================== -->\n  <nav class=\"toc\">\n    <h3>\ud83d\udcc2 \u65b9\u6848\u76ee\u5f55<\/h3>\n    <div class=\"toc-grid\">\n      <a href=\"#s1\">\ud83d\udccb \u5ba2\u6237\u4fe1\u606f<\/a>\n      <a href=\"#s2\">\ud83c\udfaf \u9700\u6c42\u4e0e\u8bbe\u8ba1\u7b56\u7565<\/a>\n      <a href=\"#s3\">\ud83d\udd35 \u65b9\u6848\u4e00\u914d\u7f6e<\/a>\n      <a href=\"#s4\">\ud83d\udfe0 \u65b9\u6848\u4e8c\u914d\u7f6e<\/a>\n      <a href=\"#s5\">\u2696\ufe0f \u5bf9\u6bd4\u5206\u6790<\/a>\n      <a href=\"#s6\">\ud83d\udccb \u62a5\u4ef7\u6e05\u5355<\/a>\n      <a href=\"#s7\">\ud83d\udee0\ufe0f \u65bd\u5de5\u4fdd\u969c<\/a>\n      <a href=\"#s8\">\u2753 \u5e38\u89c1\u95ee\u9898<\/a>\n    <\/div>\n  <\/nav>\n\n  <!-- ==================== 1. \u5ba2\u6237\u4fe1\u606f ==================== -->\n  <section id=\"s1\">\n    <div class=\"card\">\n      <h2>\ud83d\udccb \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n      <div class=\"info-grid\">\n        <div class=\"info-item\"><div class=\"label\">\u5ba2\u6237\u79f0\u547c<\/div><div class=\"value\">\u6768\u5973\u58eb<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u9879\u76ee\u4f4d\u7f6e<\/div><div class=\"value\">\u745e\u4e91\u58f9\u53f7\u6751\u5e84<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"value\">\u7ea6142.5\u33a1<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u5e38\u4f4f\u4eba\u6570<\/div><div class=\"value\">6\u4eba<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u623f\u5c4b\u7c7b\u578b<\/div><div class=\"value\">2\u5c42\u522b\u5885<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u4e3b\u8981\u9700\u6c42<\/div><div class=\"value\">\u4e2d\u592e\u7a7a\u8c03\u00b7\u5236\u51b7\u4e3a\u4e3b<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u4f7f\u7528\u7279\u70b9<\/div><div class=\"value\">1-2\u5c42\u540c\u65f6\u4f7f\u7528<\/div><\/div>\n        <div class=\"info-item\"><div class=\"label\">\u5f85\u9009\u65b9\u6848<\/div><div class=\"value\">2\u5957\u914d\u7f6e<\/div><\/div>\n      <\/div>\n\n      <p><strong>\ud83c\udfaf \u6838\u5fc3\u9700\u6c42\uff1a<\/strong>\n        2\u5c42\u522b\u58856\u4eba\u5e38\u4f4f\u00b7\u5236\u51b7\u4e3a\u4e3b\u00b71-2\u5c42\u540c\u65f6\u4f7f\u7528\u00b7\u566a\u97f3\u8212\u9002\u00b7\u6027\u4ef7\u6bd4\u4f18\u5148<\/p>\n      <p><strong>\u4f7f\u7528\u6a21\u5f0f\uff1a<\/strong> \u767d\u59291-2\u5c42\u540c\u65f6\u5f00\u542f \u2192 \u665a\u4e0a\u5404\u623f\u95f4\u72ec\u7acb\u4f7f\u7528<\/p>\n      <p><strong>\u5f85\u9009\u65b9\u6848\uff1a<\/strong>\n        <span class=\"plan-badge plan-a\">\u65b9\u6848\u4e00<\/span> \u8212\u4eabRAS-224HRNBQ\u53cc\u98ce\u6247\u4e00\u62d6\u4e03\n        <span style=\"margin:0 8px\">|<\/span>\n        <span class=\"plan-badge plan-b\">\u65b9\u6848\u4e8c<\/span> \u8212\u4eabRAS-100HRNAQ+RAS-160HRNAQ\u5206\u5c42\u4e24\u5957<\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 2. \u9700\u6c42\u4e0e\u8bbe\u8ba1\u7b56\u7565 ==================== -->\n  <section id=\"s2\">\n    <div class=\"card\">\n      <h2>\ud83c\udfaf \u9700\u6c42\u4e0e\u8bbe\u8ba1\u7b56\u7565<\/h2>\n\n      <h3>\u5ba2\u6237\u60c5\u51b5<\/h3>\n      <p>\u745e\u4e91\u58f9\u53f7\u6751\u5e842\u5c42\u522b\u5885\uff0c\u5168\u5bb66\u4eba\u5e38\u4f4f\uff0c1\u697c2\u697c\u5747\u4f1a\u5f00\u542f\u7a7a\u8c03\uff0c\u4ee5\u5236\u51b7\u4e3a\u4e3b\u30026\u4eba\u5bb6\u5ead\u7684\u65e5\u5e38\u4f7f\u7528\u573a\u666f\u5bf9\u7cfb\u7edf\u7684<strong>\u51b7\u91cf\u5206\u914d\u3001\u8fd0\u884c\u7a33\u5b9a\u6027\u3001\u80fd\u6548\u8868\u73b0<\/strong>\u6709\u4e00\u5b9a\u8981\u6c42\u3002<\/p>\n\n      <h3>\u6838\u5fc3\u8bbe\u8ba1\u7b56\u7565<\/h3>\n      <p>\ud83d\udd35 <strong>\u65b9\u6848\u4e00\uff1a\u96c6\u4e2d\u5f0f\u7cfb\u7edf<\/strong> \u2014 \u5355\u53f022.4kW\u5927\u5916\u673aRAS-224HRNBQ\u8fde\u63a5\u5168\u5c4b7\u53f0\u5185\u673a\uff0c\u7cfb\u7edf\u96c6\u4e2d\u3001\u7ba1\u7406\u7b80\u4fbf\u3001\u53ea\u97001\u4e2a\u5916\u673a\u4f4d\u3002<\/p>\n      <p>\ud83d\udfe0 <strong>\u65b9\u6848\u4e8c\uff1a\u5206\u5c42\u72ec\u7acb\u7cfb\u7edf<\/strong> \u2014 1\u697c10kW+2\u697c15.5kW\u4e24\u53f0\u5916\u673a\u72ec\u7acb\u8fd0\u884c\uff0c\u4e92\u4e3a\u4fdd\u969c\u3001\u8fde\u63a5\u7387\u66f4\u5408\u7406\u3001\u72ec\u7acb\u8c03\u63a7\u3002<\/p>\n\n      <h3>\u2705 \u9700\u6c42\u6838\u5bf9\u8868 \u2014 \u65b9\u6848\u662f\u5426\u6ee1\u8db3\uff1f<\/h3>\n      <table class=\"checklist\">\n        <tr><th>#<\/th><th>\u5ba2\u6237\u9700\u6c42<\/th><th>\u65b9\u6848\u4e00<\/th><th>\u65b9\u6848\u4e8c<\/th><\/tr>\n        <tr><td>1<\/td><td>2\u5c42\u540c\u65f6\u4f7f\u7528\u7a7a\u8c03<\/td><td>\u2713 \u6ee1\u8db3<\/td><td>\u2713 \u6ee1\u8db3<\/td><\/tr>\n        <tr><td>2<\/td><td>6\u4eba\u5236\u51b7\u8212\u9002\u00b7\u51b7\u91cf\u5145\u8db3<\/td><td>\u2713 \u6ee1\u8db3\uff0829.1kW\u5185\u673a\u603b\u51b7\u91cf\uff09<\/td><td>\u2713 \u6ee1\u8db3\uff0830.1kW\u5185\u673a\u603b\u51b7\u91cf\uff09<\/td><\/tr>\n        <tr><td>3<\/td><td>\u5ba2\u9910\u5385\u5927\u7a7a\u95f4\u8986\u76d6<\/td><td>\u2713 90\u578b+32\u578b\u53cc\u5185\u673a\uff0812.2kW\uff09<\/td><td>\u2713 \u5ba2\u538590\u578b+\u9910\u538536\u578b\uff0812.6kW\uff09<\/td><\/tr>\n        <tr><td>4<\/td><td>\u7cfb\u7edf\u7a33\u5b9a\u00b7\u6545\u969c\u5197\u4f59<\/td><td>\u26a0 \u5355\u5916\u673a\uff0c\u5355\u70b9\u6545\u969c<\/td><td>\u2713 \u53cc\u5916\u673a\u4e92\u4e3a\u5907\u4efd<\/td><\/tr>\n        <tr><td>5<\/td><td>\u7cfb\u7edf\u72ec\u7acb\u8c03\u63a7<\/td><td>\u26a0 1-2\u697c\u5171\u7528\u5916\u673a<\/td><td>\u2713 \u5206\u5c42\u72ec\u7acb\u7cfb\u7edf<\/td><\/tr>\n        <tr><td>6<\/td><td>\u6027\u4ef7\u6bd4\u4f18\u5148<\/td><td>\u2713 \u603b\u4ef752,821\u5143<\/td><td>\u2713 \u603b\u4ef752,911\u5143\uff08\u4ec5\u5dee90\u5143\uff09<\/td><\/tr>\n      <\/table>\n      <p class=\"note\"><strong>\u5168\u90e8\u5bf9\u7167\u7ed3\u8bba\uff1a<\/strong> \u4e24\u5957\u65b9\u6848\u5747\u80fd\u6ee1\u8db3\u6768\u5973\u58eb\u7684\u6838\u5fc3\u9700\u6c42\uff0c\u65b9\u6848\u4e8c\u5728\u7cfb\u7edf\u5197\u4f59\u548c\u72ec\u7acb\u8c03\u63a7\u4e0a\u7565\u4f18\uff0c\u65b9\u6848\u4e00\u5728\u7cfb\u7edf\u96c6\u4e2d\u6027\u4e0a\u66f4\u4f18\u3002<\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 3. \u65b9\u6848\u4e00\u914d\u7f6e ==================== -->\n  <section id=\"s3\">\n    <div class=\"card\">\n      <h2>\ud83d\udd35 \u65b9\u6848\u4e00\uff1aRAS-224HRNBQ \u4e00\u62d6\u4e03<\/h2>\n      <p><span class=\"plan-badge plan-a\">\u65b9\u6848\u4e00<\/span> \u8212\u4eabRAS-224HRNBQ\u53cc\u98ce\u6247 \u00b7 \u5355\u53f022.4kW\u5916\u673a \u00b7 \u8fde\u63a5\u5168\u5c4b7\u53f0\u5185\u673a<\/p>\n      <p class=\"note\">\ud83d\udcce <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd \u2192<\/a><\/p>\n\n      <h3>\u2699\ufe0f \u914d\u7f6e\u901f\u89c8<\/h3>\n      <div class=\"config-cards\">\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83d\udecb\ufe0f \u5ba2\u9910\u5385\uff08\u5ba2\u5385\u533a\uff09<\/div>\n          <div class=\"area\">53\u33a1<\/div>\n          <div class=\"unit\">RPIZ-90FSVNZQD\/P \u00b7 9.0kW<\/div>\n        <\/div>\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83c\udf7d\ufe0f \u5ba2\u9910\u5385\uff08\u9910\u5385\u533a\uff09<\/div>\n          <div class=\"area\">53\u33a1<\/div>\n          <div class=\"unit\">RPIZ-32FSNAQD\/P \u00b7 3.2kW<\/div>\n        <\/div>\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83d\udecc \u8001\u4eba\u623f1+\u8336\u5ba4<\/div>\n          <div class=\"area\">25\u33a1<\/div>\n          <div class=\"unit\">RPIZ-50FSNAQD\/P \u00b7 5.0kW<\/div>\n        <\/div>\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83d\udecc \u8001\u4eba\u623f2<\/div>\n          <div class=\"area\">13\u33a1<\/div>\n          <div class=\"unit\">RPIZ-22FSNAQD\/P \u00b7 2.2kW<\/div>\n        <\/div>\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83d\udecc \u4e3b\u5367<\/div>\n          <div class=\"area\">25\u33a1<\/div>\n          <div class=\"unit\">RPIZ-50FSNAQD\/P \u00b7 5.0kW<\/div>\n        <\/div>\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83d\udecc \u5973\u513f\u623f1<\/div>\n          <div class=\"area\">13.5\u33a1<\/div>\n          <div class=\"unit\">RPIZ-25FSNAQD\/P \u00b7 2.5kW<\/div>\n        <\/div>\n        <div class=\"config-card\">\n          <div class=\"room\">\ud83d\udecc \u5973\u513f\u623f2<\/div>\n          <div class=\"area\">13\u33a1<\/div>\n          <div class=\"unit\">RPIZ-22FSNAQD\/P \u00b7 2.2kW<\/div>\n        <\/div>\n        <div class=\"config-card\" style=\"background: var(--primary-light); border-color: var(--primary);\">\n          <div class=\"room\" style=\"color:var(--primary);\">\ud83d\udce6 \u5916\u673a<\/div>\n          <div class=\"area\">7\u53f0\u5185\u673a \u00b7 \u603b\u51b7\u91cf29.1kW<\/div>\n          <div class=\"unit\">RAS-224HRNBQ \u00b7 22.4kW<\/div>\n          <div style=\"font-size:0.85em; color:var(--text-secondary); margin-top:6px;\">\u8fde\u63a5\u7387129.9%<\/div>\n        <\/div>\n      <\/div>\n\n      <h3>\ud83d\udd2c \u6838\u5fc3\u7279\u6027<\/h3>\n      <div class=\"feature-grid\">\n        <div class=\"feature-card\">\n          <span class=\"tag tag-biaopei\">\u6807\u914d<\/span>\n          <h4>\ud83e\uddf9 \u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6d88\u6bd2<\/h4>\n          <p>\u4e8c\u6b21\u7ed3\u51b0\u81a8\u80c0\u5265\u79bb\u6c61\u57a2+60\u2103\u9664\u83cc30\u5206\u949f\uff0c\u6740\u83cc\u738795%<\/p>\n        <\/div>\n        <div class=\"feature-card\">\n          <span class=\"tag tag-xuanpei\">\u9009\u914d<\/span>\n          <h4>\ud83c\udf3f PE\u751f\u6001\u51c0\u5316\u6a21\u5757<\/h4>\n          <p>PM2.5\u53bb\u966494.46%\uff0cH3N2\u75c5\u6bd2\u53bb\u966496.85%<\/p>\n        <\/div>\n        <div class=\"feature-card\">\n          <span class=\"tag tag-hexin\">\u6838\u5fc3<\/span>\n          <h4>\u26a1 \u5168\u76f4\u6d41\u53d8\u9891<\/h4>\n          <p>APF 5.0\uff0c\u4f4e\u9891\u8fd0\u884c\u5355\u5f00\u623f\u95f4\u2248800W<\/p>\n        <\/div>\n        <div class=\"feature-card\">\n          <span class=\"tag tag-hexin\">\u6838\u5fc3<\/span>\n          <h4>\ud83d\udd07 \u8d85\u9759\u97f3<\/h4>\n          <p>\u8717\u58f3\u6574\u6d41\u788e\u6da1\u6280\u672f\uff0c\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f3<\/p>\n        <\/div>\n      <\/div>\n\n      <h3>\u65b9\u6848\u4e00\u7279\u70b9<\/h3>\n      <p><span class=\"tag tag-green\">\u4f18\u52bf<\/span> \u7cfb\u7edf\u96c6\u4e2d\u30011\u4e2a\u5916\u673a\u4f4d\u3001\u7ef4\u62a4\u7b80\u6377\u3001\u8bbe\u5907\u603b\u4ef7\u4f4e\u3002<\/p>\n      <p><span class=\"tag tag-red\">\u6ce8\u610f<\/span> \u8fde\u63a5\u7387129.9%\u8f83\u9ad8\u30011-2\u697c\u5171\u7528\u5916\u673a\u65e0\u5907\u4efd\u3002<\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 4. \u65b9\u6848\u4e8c\u914d\u7f6e ==================== -->\n  <section id=\"s4\">\n    <div class=\"card\">\n      <h2>\ud83d\udfe0 \u65b9\u6848\u4e8c\uff1aRAS-100HRNAQ + RAS-160HRNAQ \u5206\u5c42\u4e24\u5957<\/h2>\n      <p><span class=\"plan-badge plan-b\">\u65b9\u6848\u4e8c<\/span> 1\u697cRAS-100HRNAQ\u5355\u98ce\u624710kW + 2\u697cRAS-160HRNAQ\u5355\u98ce\u624715.5kW \u00b7 \u4e24\u53f0\u5916\u673a\u72ec\u7acb\u8fd0\u884c<\/p>\n      <p class=\"note\">\ud83d\udcce <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd \u2192<\/a><\/p>\n\n      <h3>\u2699\ufe0f \u914d\u7f6e\u901f\u89c8<\/h3>\n      <div style=\"display:grid; grid-template-columns:1fr 1fr; gap:14px; margin:16px 0;\">\n        <div style=\"background:#f0f6fa; border-radius:8px; padding:14px;\">\n          <h4 style=\"margin:0 0 10px; color:var(--primary);\">\ud83c\udfe0 \u4e00\u5c42\uff08RAS-100HRNAQ\uff09<\/h4>\n          <div style=\"font-size:0.9em;\">\n            \ud83c\udf7d\ufe0f \u9910\u538513\u33a1 \u00b7 36\u578b 3.6kW<br>\n            \ud83d\udecc \u8001\u4eba\u623f1+\u8336\u5ba425\u33a1 \u00b7 50\u578b 5.0kW<br>\n            \ud83d\udecc \u8001\u4eba\u623f2 13\u33a1 \u00b7 22\u578b 2.2kW<br>\n            <span style=\"font-weight:600;color:var(--primary);\">\u5408\u8ba1\uff1a10.8kW \u00b7 \u8fde\u63a5\u7387108%<\/span>\n          <\/div>\n        <\/div>\n        <div style=\"background:#fef4e8; border-radius:8px; padding:14px;\">\n          <h4 style=\"margin:0 0 10px; color:var(--orange);\">\ud83c\udfe0 \u4e8c\u5c42\uff08RAS-160HRNAQ\uff09<\/h4>\n          <div style=\"font-size:0.9em;\">\n            \ud83d\udecb\ufe0f \u5ba2\u538540\u33a1 \u00b7 90\u578b 9.0kW<br>\n            \ud83d\udecc \u4e3b\u536725\u33a1 \u00b7 50\u578b 5.0kW<br>\n            \ud83d\udecc \u5973\u513f\u623f1 13.5\u33a1 \u00b7 28\u578b 2.8kW<br>\n            \ud83d\udecc \u5973\u513f\u623f2 13\u33a1 \u00b7 25\u578b 2.5kW<br>\n            <span style=\"font-weight:600;color:var(--orange);\">\u5408\u8ba1\uff1a19.3kW \u00b7 \u8fde\u63a5\u7387124.5%<\/span>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <h3>\ud83d\udd2c \u6838\u5fc3\u7279\u6027<\/h3>\n      <div class=\"feature-grid\">\n        <div class=\"feature-card\">\n          <span class=\"tag tag-biaopei\">\u6807\u914d<\/span>\n          <h4>\ud83e\uddf9 \u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u6d88\u6bd2<\/h4>\n          <p>\u4e8c\u6b21\u7ed3\u51b0+60\u2103\u9664\u83cc30\u5206\u949f\uff0c\u6740\u83cc\u738795%<\/p>\n        <\/div>\n        <div class=\"feature-card\">\n          <span class=\"tag tag-hexin\">\u6838\u5fc3<\/span>\n          <h4>\u26a1 \u5168\u76f4\u6d41\u53d8\u9891 APF 5.7\/5.5<\/h4>\n          <p>\u4e24\u53f0\u5916\u673aAPF\u5206\u522b5.7\u548c5.5\uff0c\u9ad8\u4e8e\u65b9\u6848\u4e00<\/p>\n        <\/div>\n        <div class=\"feature-card\">\n          <span class=\"tag tag-hexin\">\u6838\u5fc3<\/span>\n          <h4>\ud83d\udd04 \u53cc\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c<\/h4>\n          <p>1-2\u5c42\u5404\u81ea\u72ec\u7acb\uff0c\u4e00\u5c42\u6545\u969c\u4e0d\u5f71\u54cd\u53e6\u4e00\u5c42<\/p>\n        <\/div>\n        <div class=\"feature-card\">\n          <span class=\"tag tag-hexin\">\u6838\u5fc3<\/span>\n          <h4>\ud83d\udcca \u8fde\u63a5\u7387\u5408\u7406<\/h4>\n          <p>\u4e00\u5c42108%\uff0c\u4e8c\u5c42124.5%\uff0c\u5916\u673a\u4e0d\u6613\u6ee1\u8f7d<\/p>\n        <\/div>\n      <\/div>\n\n      <h3>\u65b9\u6848\u4e8c\u7279\u70b9<\/h3>\n      <p><span class=\"tag tag-green\">\u4f18\u52bf<\/span> \u4e24\u5c42\u72ec\u7acb\u7cfb\u7edf\u3001APF\u66f4\u9ad8\u3001\u8fde\u63a5\u7387\u5408\u7406\u3001\u4e92\u4e3a\u5907\u4efd\u3002<\/p>\n      <p><span class=\"tag tag-red\">\u6ce8\u610f<\/span> \u97002\u4e2a\u5916\u673a\u4f4d\u3001\u5b89\u88c5\u6750\u6599\u7565\u591a\u3002<\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 5. \u5bf9\u6bd4\u5206\u6790 ==================== -->\n  <section id=\"s5\">\n    <div class=\"card\">\n      <h2>\u2696\ufe0f \u5bf9\u6bd4\u5206\u6790<\/h2>\n\n      <h3>\u7efc\u5408\u5bf9\u6bd4\u8868<\/h3>\n      <table class=\"comparison-table\">\n        <tr><th>\u5bf9\u6bd4\u9879<\/th><th>\ud83d\udd35 \u65b9\u6848\u4e00<\/th><th>\ud83d\udfe0 \u65b9\u6848\u4e8c<\/th><\/tr>\n        <tr><td>\u5ba4\u5916\u673a\u914d\u7f6e<\/td><td>RAS-224HRNBQ \u53cc\u98ce\u6247\u00d71<\/td><td>RAS-100HRNAQ+RAS-160HRNAQ \u5355\u98ce\u6247\u00d72<\/td><\/tr>\n        <tr><td>\u5ba4\u5185\u673a<\/td><td>7\u53f0 \u00b7 \u603b\u51b7\u91cf29.1kW<\/td><td>7\u53f0 \u00b7 \u603b\u51b7\u91cf30.1kW<\/td><\/tr>\n        <tr><td>\u5ba4\u5916\u603b\u51b7\u91cf<\/td><td>22.4kW<\/td><td>25.5kW<\/td><\/tr>\n        <tr><td>\u8fde\u63a5\u7387<\/td><td>129.9%<\/td><td>108% \/ 124.5%<\/td><\/tr>\n        <tr><td>\u7efc\u5408APF<\/td><td>5.0<\/td><td>\u5e73\u5747\u7ea65.6<\/td><\/tr>\n        <tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td>50dB<\/td><td>53-54dB<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u72ec\u7acb\u6027<\/td><td>1\u5957\u7cfb\u7edf<\/td><td>2\u5957\u72ec\u7acb\u7cfb\u7edf<\/td><\/tr>\n        <tr><td>\u5916\u673a\u4f4d<\/td><td>1\u4e2a<\/td><td>2\u4e2a<\/td><\/tr>\n        <tr><td>\u6545\u969c\u5197\u4f59<\/td><td>\u5355\u70b9\u6545\u969c<\/td><td>\u4e92\u4e3a\u5907\u4efd<\/td><\/tr>\n        <tr><td><strong>\u65b9\u6848\u603b\u4ef7<\/strong><\/td><td><strong>52,821\u5143<\/strong><\/td><td><strong>52,911\u5143<\/strong><\/td><\/tr>\n      <\/table>\n\n      <h3>\u4f18\u7f3a\u70b9\u5bf9\u6bd4<\/h3>\n      <table>\n        <tr><th style=\"width:80px;\">\u7ef4\u5ea6<\/th><th>\ud83d\udd35 \u65b9\u6848\u4e00<\/th><th>\ud83d\udfe0 \u65b9\u6848\u4e8c<\/th><\/tr>\n        <tr><td>\u4f18\u52bf<\/td>\n          <td>\u00b7 \u7cfb\u7edf\u96c6\u4e2d\uff0c1\u4e2a\u5916\u673a\u4f4d<br>\u00b7 \u4e00\u5957\u7cfb\u7edf\u7ef4\u62a4\u65b9\u4fbf<br>\u00b7 \u5ba2\u9910\u538590\u578b+32\u578b\u53cc\u5185\u673a\u8986\u76d6<\/td>\n          <td>\u00b7 \u4e24\u5c42\u72ec\u7acb\uff0c\u4e92\u4e0d\u5e72\u6270<br>\u00b7 \u8fde\u63a5\u7387\u5408\u7406\uff0c\u5916\u673a\u4e0d\u6613\u6ee1\u8f7d<br>\u00b7 APF\u66f4\u9ad8\uff0c\u957f\u671f\u66f4\u7701\u7535<br>\u00b7 \u53cc\u5916\u673a\u4e92\u4e3a\u5907\u4efd<\/td>\n        <\/tr>\n        <tr><td>\u52a3\u52bf<\/td>\n          <td>\u00b7 \u8fde\u63a5\u7387129.9%\u9ad8\u5cf0\u4f59\u91cf\u5c0f<br>\u00b7 \u5916\u673a\u6545\u969c\u5168\u5c4b\u505c\u6446<br>\u00b7 \u5927\u5916\u673a\u4f4e\u8d1f\u8377\u6548\u7387\u4e0b\u964d<\/td>\n          <td>\u00b7 \u97002\u4e2a\u5916\u673a\u4f4d<br>\u00b7 \u4e24\u53f0\u5916\u673a\u566a\u97f3\u53e0\u52a0<br>\u00b7 \u5b89\u88c5\u7565\u590d\u6742<\/td>\n        <\/tr>\n      <\/table>\n\n      <h3>\u26a1 \u80fd\u8017\u5bf9\u6bd4<\/h3>\n      <table>\n        <tr><th>\u573a\u666f<\/th><th>\u65b9\u6848\u4e00\u4f30\u7b97<\/th><th>\u65b9\u6848\u4e8c\u4f30\u7b97<\/th><\/tr>\n        <tr><td>\u4e24\u5c42\u540c\u65f6\u5f00\u542f<\/td><td>\u7ea621.5kWh\/\u5929<\/td><td>\u7ea621.9kWh\/\u5929<\/td><\/tr>\n        <tr><td>\u4ec5\u4e00\u5c42\u5f00\u542f<\/td><td>\u7ea68-10kWh\/\u5929\uff08\u4f4e\u8d1f\u8377\u6548\u7387\u2193\uff09<\/td><td>\u7ea65-7kWh\/\u5929\uff08\u5355\u53f0\u9ad8\u6548\u8fd0\u884c\uff09<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u5b63\u4f30\u7b97\uff08120\u5929\uff09<\/td><td>\u7ea62,580-2,900kWh<\/td><td>\u7ea62,500-2,800kWh<\/td><\/tr>\n      <\/table>\n\n      <h3>\ud83d\udcb0 \u4ef7\u683c\u5bf9\u6bd4<\/h3>\n      <table>\n        <tr><th>\u8d39\u7528\u9879<\/th><th>\ud83d\udd35 \u65b9\u6848\u4e00<\/th><th>\ud83d\udfe0 \u65b9\u6848\u4e8c<\/th><\/tr>\n        <tr><td>\u8bbe\u5907\u9762\u4ef7<\/td><td>49,089\u5143<\/td><td>49,951\u5143<\/td><\/tr>\n        <tr><td>\u8bbe\u59078\u6298\u4ef7<\/td><td><strong>39,271\u5143<\/strong><\/td><td><strong>39,961\u5143<\/strong><\/td><\/tr>\n        <tr><td>\u7ebf\u63a7\u5668<\/td><td>1,750\u5143<\/td><td>1,750\u5143<\/td><\/tr>\n        <tr><td>\u5b89\u88c5\u8d39<\/td><td>11,800\u5143<\/td><td>11,200\u5143<\/td><\/tr>\n        <tr><td><strong>\u65b9\u6848\u603b\u4ef7<\/strong><\/td><td><strong>52,821\u5143<\/strong><\/td><td><strong>52,911\u5143<\/strong><\/td><\/tr>\n      <\/table>\n      <p>\u4e24\u5957\u65b9\u6848\u603b\u4ef7\u4ec5\u5dee <span class=\"highlight\">90\u5143<\/span>\uff08\u4e0d\u52300.2%\uff09\uff0c\u51e0\u4e4e\u6301\u5e73\u3002<\/p>\n\n      <div class=\"recommend-box\">\n        <h4>\ud83d\udca1 \u9009\u578b\u5efa\u8bae<\/h4>\n        <p>\u4ef7\u683c\u51e0\u4e4e\u4e00\u6837\uff0c\u5173\u952e\u5728\u4e8e\u7cfb\u7edf\u67b6\u6784\u504f\u597d\uff1a<\/p>\n        <p>\u504f\u597d<strong>\u96c6\u4e2d\u5f0f\uff081\u4e2a\u5916\u673a\u4f4d\u3001\u4e00\u5957\u7ef4\u62a4\uff09<\/strong> \u2192 \u9009 <strong>\u65b9\u6848\u4e00<\/strong><\/p>\n        <p>\u504f\u597d<strong>\u5206\u5c42\u72ec\u7acb\uff08\u53cc\u7cfb\u7edf\u5907\u4efd\u3001\u72ec\u7acb\u8c03\u63a7\u3001\u8fde\u63a5\u7387\u66f4\u4f18\uff09<\/strong> \u2192 \u9009 <strong>\u65b9\u6848\u4e8c<\/strong><\/p>\n        <p>\u7ed3\u5408\u60a8\"1\u697c2\u697c\u90fd\u4f1a\u540c\u65f6\u6253\u5f00\"\u7684\u4f7f\u7528\u9700\u6c42\uff0c<strong>\u65b9\u6848\u4e8c\u5728\u7cfb\u7edf\u5197\u4f59\u548c\u72ec\u7acb\u8c03\u63a7\u4e0a\u66f4\u8d34\u5408\u5b9e\u9645\u573a\u666f<\/strong>\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 6. \u62a5\u4ef7\u6e05\u5355 ==================== -->\n  <section id=\"s6\">\n    <div class=\"card\">\n      <h2>\ud83d\udccb \u65b9\u6848\u4e0e\u900f\u660e\u62a5\u4ef7<\/h2>\n\n      <h3>\ud83d\udcd0 \u623f\u95f4\u8d1f\u8377\u8ba1\u7b97<\/h3>\n      <table>\n        <tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5355\u4f4d\u51b7\u8d1f\u8377<\/th><th>\u65b9\u6848\u4e00\u5185\u673a<\/th><th>\u65b9\u6848\u4e8c\u5185\u673a<\/th><\/tr>\n        <tr><td>\u5ba2\u9910\u5385\/\u5ba2\u5385<\/td><td>53\/40\u33a1<\/td><td>180W\/\u33a1<\/td><td>90\u578b+32\u578b(12.2kW)<\/td><td>90\u578b(9kW)<\/td><\/tr>\n        <tr><td>\u9910\u5385<\/td><td>13\u33a1<\/td><td>180W\/\u33a1<\/td><td>\u2014\uff08\u5df2\u542b\u5ba2\u9910\u5385\uff09<\/td><td>36\u578b(3.6kW)<\/td><\/tr>\n        <tr><td>\u8001\u4eba\u623f1+\u8336\u5ba4<\/td><td>25\u33a1<\/td><td>180W\/\u33a1<\/td><td>50\u578b(5.0kW)<\/td><td>50\u578b(5.0kW)<\/td><\/tr>\n        <tr><td>\u8001\u4eba\u623f2<\/td><td>13\u33a1<\/td><td>180W\/\u33a1<\/td><td>22\u578b(2.2kW)<\/td><td>22\u578b(2.2kW)<\/td><\/tr>\n        <tr><td>\u4e3b\u5367<\/td><td>25\u33a1<\/td><td>180W\/\u33a1<\/td><td>50\u578b(5.0kW)<\/td><td>50\u578b(5.0kW)<\/td><\/tr>\n        <tr><td>\u5973\u513f\u623f1<\/td><td>13.5\u33a1<\/td><td>180W\/\u33a1<\/td><td>25\u578b(2.5kW)<\/td><td>28\u578b(2.8kW)<\/td><\/tr>\n        <tr><td>\u5973\u513f\u623f2<\/td><td>13\u33a1<\/td><td>180W\/\u33a1<\/td><td>22\u578b(2.2kW)<\/td><td>25\u578b(2.5kW)<\/td><\/tr>\n        <tr><th>\u5408\u8ba1<\/th><th>142.5\u33a1<\/th><th>\u2014<\/th><th>29.1kW \/ 129.9%<\/th><th>30.1kW \/ 108%+124.5%<\/th><\/tr>\n      <\/table>\n\n      <h3>\ud83d\udce6 \u914d\u7f6e\u6e05\u5355 \u00b7 \u65b9\u6848\u4e00<\/h3>\n      <table>\n        <tr><th>#<\/th><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u6298\u540e\u4ef7<\/th><\/tr>\n        <tr><td>1<\/td><td>\u8212\u4eab\u53cc\u98ce\u6247\u5916\u673a<\/td><td>RAS-224HRNBQ<\/td><td>1<\/td><td>19,420\u5143<\/td><\/tr>\n        <tr><td>2<\/td><td>\u8584\u578b\u98ce\u7ba1\u673a90\u578b<\/td><td>RPIZ-90FSVNZQD\/P<\/td><td>1<\/td><td>4,790\u5143<\/td><\/tr>\n        <tr><td>3<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a32\u578b<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>2<\/td><td>4,960\u5143<\/td><\/tr>\n        <tr><td>4<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a50\u578b<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>2<\/td><td>5,320\u5143<\/td><\/tr>\n        <tr><td>5<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a22\u578b<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2<\/td><td>4,820\u5143<\/td><\/tr>\n        <tr><td>6<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a25\u578b<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>1<\/td><td>2,440\u5143<\/td><\/tr>\n        <tr><td>7<\/td><td>WiFi\u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>7<\/td><td>1,750\u5143<\/td><\/tr>\n        <tr><td>\u2014<\/td><td>\u5b89\u88c5\u8d39<\/td><td>\u5ba4\u5916600+\u5ba4\u51857\u00d71,600<\/td><td>\u2014<\/td><td>11,800\u5143<\/td><\/tr>\n        <tr><th colspan=\"4\">\u65b9\u6848\u4e00\u603b\u4ef7<\/th><th><strong>52,821\u5143<\/strong><\/th><\/tr>\n      <\/table>\n\n      <h3>\ud83d\udce6 \u914d\u7f6e\u6e05\u5355 \u00b7 \u65b9\u6848\u4e8c<\/h3>\n      <table>\n        <tr><th>#<\/th><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u6298\u540e\u4ef7<\/th><\/tr>\n        <tr><td>1<\/td><td>\u8212\u4eab\u5355\u98ce\u6247\u5916\u673a<\/td><td>RAS-100HRNAQ<\/td><td>1<\/td><td>9,020\u5143<\/td><\/tr>\n        <tr><td>2<\/td><td>\u8212\u4eab\u5355\u98ce\u6247\u5916\u673a<\/td><td>RAS-160HRNAQ<\/td><td>1<\/td><td>11,020\u5143<\/td><\/tr>\n        <tr><td>3<\/td><td>\u8584\u578b\u98ce\u7ba1\u673a90\u578b<\/td><td>RPIZ-90FSVNZQD\/P<\/td><td>1<\/td><td>4,790\u5143<\/td><\/tr>\n        <tr><td>4<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a36\u578b<\/td><td>RPIZ-36FSNAQD\/P<\/td><td>1<\/td><td>2,500\u5143<\/td><\/tr>\n        <tr><td>5<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a50\u578b<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>2<\/td><td>5,320\u5143<\/td><\/tr>\n        <tr><td>6<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a28\u578b<\/td><td>RPIZ-28FSNAQD\/P<\/td><td>1<\/td><td>2,460\u5143<\/td><\/tr>\n        <tr><td>7<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a25\u578b<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>1<\/td><td>2,440\u5143<\/td><\/tr>\n        <tr><td>8<\/td><td>\u8212\u4eab\u98ce\u7ba1\u673a22\u578b<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1<\/td><td>2,410\u5143<\/td><\/tr>\n        <tr><td>9<\/td><td>WiFi\u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>7<\/td><td>1,750\u5143<\/td><\/tr>\n        <tr><td>\u2014<\/td><td>\u5b89\u88c5\u8d39<\/td><td>\u5ba4\u51857\u00d71,600<\/td><td>\u2014<\/td><td>11,200\u5143<\/td><\/tr>\n        <tr><th colspan=\"4\">\u65b9\u6848\u4e8c\u603b\u4ef7<\/th><th><strong>52,911\u5143<\/strong><\/th><\/tr>\n      <\/table>\n\n      <h3>\ud83d\udcb0 \u7edf\u4e00\u62a5\u4ef7\u5bf9\u6bd4<\/h3>\n      <div class=\"price-grid\">\n        <div class=\"price-card selected\">\n          <div class=\"price-title\"><span class=\"plan-badge plan-a\">\u65b9\u6848\u4e00<\/span> RAS-224HRNBQ\u4e00\u62d6\u4e03<\/div>\n          <div class=\"price-amount\">\u00a552,821<\/div>\n          <div class=\"price-note\">\u8bbe\u59078\u6298\u540e39,271 + \u7ebf\u63a7\u56681,750 + \u5b89\u88c511,800<\/div>\n          <hr>\n          <div class=\"price-row\"><span>\u8bbe\u5907\u9762\u4ef7<\/span><span>49,089\u5143<\/span><\/div>\n          <div class=\"price-row\"><span>\u8bbe\u59078\u6298\u4ef7<\/span><span>39,271\u5143<\/span><\/div>\n          <div class=\"price-row\"><span>\u7ebf\u63a7\u5668<\/span><span>1,750\u5143<\/span><\/div>\n          <div class=\"price-row\"><span>\u5b89\u88c5\u8d39<\/span><span>11,800\u5143<\/span><\/div>\n          <div class=\"price-row total\"><span>\u603b\u4ef7<\/span><span>52,821\u5143<\/span><\/div>\n        <\/div>\n        <div class=\"price-card\">\n          <div class=\"price-title\"><span class=\"plan-badge plan-b\">\u65b9\u6848\u4e8c<\/span> RAS-100+160HRNAQ\u5206\u5c42\u4e24\u5957<\/div>\n          <div class=\"price-amount\">\u00a552,911<\/div>\n          <div class=\"price-note\">\u8bbe\u59078\u6298\u540e39,961 + \u7ebf\u63a7\u56681,750 + \u5b89\u88c511,200<\/div>\n          <hr>\n          <div class=\"price-row\"><span>\u8bbe\u5907\u9762\u4ef7<\/span><span>49,951\u5143<\/span><\/div>\n          <div class=\"price-row\"><span>\u8bbe\u59078\u6298\u4ef7<\/span><span>39,961\u5143<\/span><\/div>\n          <div class=\"price-row\"><span>\u7ebf\u63a7\u5668<\/span><span>1,750\u5143<\/span><\/div>\n          <div class=\"price-row\"><span>\u5b89\u88c5\u8d39<\/span><span>11,200\u5143<\/span><\/div>\n          <div class=\"price-row total\"><span>\u603b\u4ef7<\/span><span>52,911\u5143<\/span><\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"discount-box\">\n        <strong>\ud83d\udccc \u4f18\u60e0\u4e0e\u4fdd\u969c\u8bf4\u660e<\/strong>\n        <ul style=\"margin:8px 0 0; padding-left:18px;\">\n          <li><strong>\u8bbe\u5907\u6298\u6263\uff1a<\/strong>\u6309\u4ef7\u683c\u8868\u9762\u4ef7\u62538\u6298\uff0c\u7ebf\u63a7\u5668\u53ca\u5b89\u88c5\u8d39\u4e0d\u6253\u6298\u3002<\/li>\n          <li><strong>\u4f1a\u5458\u798f\u5229\uff1a<\/strong>\u52a0\u5165\u516c\u53f8\u4f1a\u5458\u5e74\u8d39\u00a5199\uff0c\u4eab\u53d7\u5de5\u7a0b\u5ef6\u4fdd\u81f35\u5e74 + \u8bbe\u5907\u5ef6\u4fdd\u81f310\u5e74\u3002<\/li>\n          <li><strong>\u54c1\u724c\u6d3b\u52a8\uff1a<\/strong>\u5176\u4f59\u4f18\u60e0\u6839\u636e\u5546\u573a\u548c\u5382\u5bb6\u7684\u54c1\u724c\u6708\u6d3b\u52a8\u800c\u5b9a\uff0c\u534a\u5e74\u5185\u53ef\u4eab\u53d7\u6d3b\u52a8\u8865\u5dee\u3002<\/li>\n        <\/ul>\n        <p class=\"note\" style=\"margin-top:8px;\">\ud83d\udccc \u4ee5\u4e0a\u62a5\u4ef7\u4ec5\u4f9b\u53c2\u8003\uff0c\u6700\u7ec8\u4f18\u60e0\u4ee5\u7b7e\u8ba2\u5408\u540c\u4e3a\u51c6\u3002\u7cbe\u51c6\u4ef7\u683c\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u51fa\u5177\u7684\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 7. \u65bd\u5de5\u4fdd\u969c ==================== -->\n  <section id=\"s7\">\n    <div class=\"card\">\n      <h2>\ud83d\udee0\ufe0f \u65bd\u5de5\u4fdd\u969c\u00b7\u6848\u4f8b\u9a8c\u8bc1<\/h2>\n\n      <h3>\ud83d\udcd0 \u7cbe\u5de5\u516d\u6b65\u6cd5\uff08\u4e2d\u592e\u7a7a\u8c03\u4e13\u5c5e\uff09<\/h3>\n      <div class=\"steps-grid\">\n        <div class=\"step\">\n          <div class=\"num\">1<\/div>\n          <h4>\u73b0\u573a\u52d8\u6d4b<\/h4>\n          <p>\u786e\u8ba4\u6237\u578b\u3001\u540a\u9876\u3001\u94dc\u7ba1\u8d70\u5411\u3001\u5916\u673a\u4f4d<\/p>\n        <\/div>\n        <div class=\"step\">\n          <div class=\"num\">2<\/div>\n          <h4>\u7cfb\u7edf\u8bbe\u8ba1<\/h4>\n          <p>\u8d1f\u8377\u8ba1\u7b97\u00b7\u5b9a\u4f4d\u56fe\u00b7\u8d70\u5411\u56fe\u00b7\u5ba2\u6237\u786e\u8ba4<\/p>\n        <\/div>\n        <div class=\"step\">\n          <div class=\"num\">3<\/div>\n          <h4>\u6750\u6599\u9a8c\u6536<\/h4>\n          <p>\u8bbe\u5907\u8f85\u6750\u8fdb\u573a\u00b7\u5171\u540c\u9a8c\u6536\u54c1\u724c\u578b\u53f7<\/p>\n        <\/div>\n        <div class=\"step\">\n          <div class=\"num\">4<\/div>\n          <h4>\u7cfb\u7edf\u5b89\u88c5<\/h4>\n          <p>\u6309\u56fe\u65bd\u5de5\u00b7\u5145\u6c2e\u710a\u63a5\u00b7\u6bcf\u9053\u5de5\u5e8f\u62cd\u7167<\/p>\n        <\/div>\n        <div class=\"step\">\n          <div class=\"num\">5<\/div>\n          <h4>\u7cfb\u7edf\u8c03\u8bd5<\/h4>\n          <p>\u62bd\u771f\u7a7a\u2192\u8ffd\u52a0\u51b7\u5a92\u2192\u8bd5\u8fd0\u884c\u9a8c\u8bc1<\/p>\n        <\/div>\n        <div class=\"step\">\n          <div class=\"num\">6<\/div>\n          <h4>\u7ae3\u5de5\u9a8c\u6536<\/h4>\n          <p>\u5f71\u50cf\u5f52\u6863\u00b7\u4ea4\u4ed8\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b<\/p>\n        <\/div>\n      <\/div>\n\n      <h3>\u2b50 \u6848\u4f8b\u9a8c\u8bc1\u2014\u2014\u540c\u7c7b\u578b\u5ba2\u6237\u7684\u771f\u5b9e\u6548\u679c<\/h3>\n      <div class=\"case-list\">\n        <div class=\"case-item\">\n          <a href=\"https:\/\/longmai-nt.com\/?page_id=378\" target=\"_blank\">\u540c\u4e00\u4e1a\u4e3b\u00b7\u4e24\u4e2a\u5bb6\u80fd\u8017\u5bf9\u6bd4<\/a>\n          <div class=\"desc\">\u4ece\"\u80fd\u8017\u5c0f\u533a\u6700\u9ad8\"\u5230\"\u8282\u80fd\u5fc3\u91cc\u6709\u6570\"\u2014\u2014\u4e2d\u592e\u7a7a\u8c03\u4f4e\u9891\u8fd0\u884c\u5b9e\u6d4b<\/div>\n        <\/div>\n        <div class=\"case-item\">\n          <a href=\"https:\/\/longmai-nt.com\/?page_id=2899\" target=\"_blank\">\u4f73\u5146\u4e1a\u7530\u5973\u58eb\u00b7133\u33a1\u8212\u4eab\u5206\u8bbe\u53cc\u5916\u673a<\/a>\n          <div class=\"desc\">\u53e0\u62fc\u4e24\u5c42\u5206\u8bbe\u53cc\u5916\u673a\uff08140+125\uff09\uff0c\u72ec\u7acb\u8fd0\u884c\u4e92\u4e0d\u5e72\u6270\uff0c\u7eaf\u5236\u51b7\u65b9\u6848<\/div>\n        <\/div>\n        <div class=\"case-item\">\n          <a href=\"https:\/\/longmai-nt.com\/?page_id=982\" target=\"_blank\">\u6e56\u4e0e\u767dG\u8001\u5e08\u00b7\u4e2d\u592e\u7a7a\u8c03\u6863\u6848<\/a>\n          <div class=\"desc\">\u540c\u9762\u79ef\u6bb5\uff08\u7ea6110\u33a1\uff09\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u56db\u5b8c\u6574\u65b9\u6848<\/div>\n        <\/div>\n        <div class=\"case-item\">\n          <a href=\"https:\/\/longmai-nt.com\/?page_id=2815\" target=\"_blank\">\u6587\u5973\u58eb\u00b7121\u33a1\u8212\u4eab\u4e00\u62d6\u56db<\/a>\n          <div class=\"desc\">\u540c\u9762\u79ef\u6bb5\u8212\u4eab\u4e00\u62d6\u56db\u771f\u5b9e\u6848\u4f8b\uff0c\u65bd\u5de5\u914d\u7f6e\u5b8c\u6574\u5f52\u6863<\/div>\n        <\/div>\n      <\/div>\n      <p class=\"note\">\u6768\u5973\u58eb\u6848\u4f8b\u5c06\u52a0\u5165\u9f99\u8109\u6696\u901a\u6848\u4f8b\u5e93\uff1a\u9a8c\u6536\u540e\u80fd\u8017\u6570\u636e\u5c06\u8131\u654f\u5f52\u6863\uff0c\u7eb3\u5165\u540c\u6237\u578b\u5bf9\u6807\u5206\u6790\u3002<\/p>\n\n      <h3>\ud83d\udee1\ufe0f \u53cc\u91cd\u4fdd\u969c<\/h3>\n      <p><strong>\ud83d\udcc5 \u6574\u673a5\u5e74\u8d28\u4fdd<\/strong> \u2014 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6574\u673a5\u5e74\u8d28\u4fdd\uff0c\u8fdc\u8d85\u56fd\u5bb63\u5e74\u6807\u51c6\u3002<\/p>\n      <p><strong>\ud83d\udcca 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/strong> \u2014 \u80fd\u8017\u6570\u636e\u9010\u5e74\u5f52\u6863\uff0c\u540c\u6237\u578b\u5bf9\u6807\u5206\u6790\uff0c\u5f02\u5e38\u80fd\u8017\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u3002<\/p>\n\n      <h3>\ud83c\udfc6 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u8ba4\u8bc1<\/h3>\n      <p>\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743 \u00b7 \u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743 \u00b7 \u7279\u9080\u5b89\u88c5\u6388\u6743 \u00b7 \u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/p>\n      <p class=\"note\">\ud83d\udcce \u53c2\u8003\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ecb\u7ecd<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=5051\" target=\"_blank\">\u81ea\u6e05\u6d01\u6d88\u6bd2<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=5703\" target=\"_blank\">PE\u751f\u6001\u51c0\u5316<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=2170\" target=\"_blank\">3D\u4eba\u611f\u98ce\u53e3<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\u5168\u90e8\u6848\u4f8b\u805a\u5408<\/a><\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ==================== 8. FAQ ==================== -->\n  <section id=\"s8\">\n    <div class=\"card\">\n      <h2>\u2753 \u5e38\u89c1\u95ee\u9898\uff08FAQ\uff09<\/h2>\n\n      <div class=\"faq-item\">\n        <h4>\u4e24\u5957\u65b9\u6848\u4ef7\u683c\u5dee\u591a\u5c11\uff1f\u4e3a\u4ec0\u4e48\uff1f<\/h4>\n        <p>\u4ec5\u5dee90\u5143\uff0c\u51e0\u4e4e\u6301\u5e73\u3002\u65b9\u6848\u4e0052,821\u5143\uff0c\u65b9\u6848\u4e8c52,911\u5143\u3002\u4ef7\u683c\u5dee\u5f02\u6781\u5c0f\uff0c\u9009\u62e9\u5173\u952e\u5728\u4e8e\u7cfb\u7edf\u67b6\u6784\u504f\u597d\u800c\u975e\u9884\u7b97\u3002<\/p>\n      <\/div>\n\n      <div class=\"faq-item\">\n        <h4>\u65b9\u6848\u4e00\u8fde\u63a5\u7387129.9%\u662f\u5426\u504f\u9ad8\uff1f<\/h4>\n        <p>\u65e5\u7acb\u591a\u8054\u673a\u5141\u8bb8\u8fde\u63a5\u7387\u6700\u9ad8\u7ea6130%\uff0c129.9%\u5728\u5141\u8bb8\u8303\u56f4\u5185\u3002\u4f46\u9ad8\u5cf0\u65f6\u6bb5\u82e5\u5168\u90e8\u5185\u673a\u6ee1\u8d1f\u8377\uff0c\u5916\u673a\u4f59\u91cf\u8f83\u5c0f\u3002\u65e5\u5e38\u4f7f\u7528\u4e2d\u901a\u5e38\u4e0d\u4f1a\u5168\u90e8\u6ee1\u8d1f\u8377\uff0c\u8fd0\u884c\u65e0\u95ee\u9898\u3002<\/p>\n      <\/div>\n\n      <div class=\"faq-item\">\n        <h4>\u4e24\u5957\u65b9\u6848\u80fd\u8017\u5dee\u5f02\u5927\u5417\uff1f<\/h4>\n        <p>\u6574\u4f53\u5dee\u5f02\u4e0d\u5927\u3002\u65b9\u6848\u4e8cAPF\u8f83\u9ad8\uff0c\u65b9\u6848\u4e00\u7cfb\u7edf\u96c6\u4e2d\u3002\u82e5\u4e24\u5c42\u540c\u65f6\u4f7f\u7528\u9891\u7387\u9ad8\uff0c\u65b9\u6848\u4e8c\u7565\u7701\uff1b\u82e5\u5355\u5c42\u4f7f\u7528\u591a\uff0c\u65b9\u6848\u4e8c\u4f18\u52bf\u66f4\u660e\u663e\u3002<\/p>\n      <\/div>\n\n      <div class=\"faq-item\">\n        <h4>\u5efa\u8bae\u9009\u54ea\u5957\uff1f<\/h4>\n        <p>\u4ef7\u683c\u76f8\u540c\uff0c\u53d6\u51b3\u4e8e\u504f\u597d\uff1a\u559c\u6b22\u96c6\u4e2d\u5f0f\uff081\u4e2a\u5916\u673a\u4f4d\uff09\u9009\u65b9\u6848\u4e00\uff1b\u559c\u6b22\u5206\u5c42\u72ec\u7acb\uff08\u53cc\u7cfb\u7edf\u5907\u4efd\uff09\u9009\u65b9\u6848\u4e8c\u3002\u60a8\"1\u697c2\u697c\u90fd\u4f1a\u6253\u5f00\"\u7684\u4f7f\u7528\u573a\u666f\u4e0b\uff0c\u65b9\u6848\u4e8c\u7684\u7cfb\u7edf\u5197\u4f59\u66f4\u7a33\u59a5\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/section>\n\n<\/div>\n\n<!-- ==================== Footer ==================== -->\n<footer>\n  <p><strong>\u6768\u5973\u58eb\uff0c\u8fd9\u5957\u5bf9\u6bd4\u65b9\u6848\u662f\u5426\u6ee1\u8db3\u60a8\u7684\u9700\u6c42\uff1f<\/strong><\/p>\n  <p>\u5982\u6709\u7591\u95ee\uff0c\u6b22\u8fce\u968f\u65f6\u8054\u7cfb\u3002<\/p>\n  <p class=\"tel\">\ud83d\udcde \u5357\u5bcc\u68ee\u5e97 028-86131795\u3000\uff5c\u3000\ud83d\udcde \u5317\u5bcc\u68ee\u5e97 028-65272586<\/p>\n  <p class=\"store\">\ud83c\udfea \u5357\u5bcc\u68ee\u5e97\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/p>\n  <p class=\"store\">\ud83c\udfea \u5317\u5bcc\u68ee\u5e97\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/p>\n  <p>\u552e\u540e\uff1a028-61649321 | \u8f9c\u7ecf\u7406 13183879308 | longmai-nt.com<\/p>\n  <p style=\"margin-top:12px; font-size:0.85em; color:#666;\">\u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u4e13\u4e1a\u6696\u901a\u670d\u52a1\u5546<\/p>\n<\/footer>\n\n","protected":false},"excerpt":{"rendered":"<p>\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-5970","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=5970\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=5970\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-09T09:28:17+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5970\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5970\",\"name\":\"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-07-09T09:28:16+00:00\",\"dateModified\":\"2026-07-09T09:28:17+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5970#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5970\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=5970#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=5970","og_locale":"zh_CN","og_type":"article","og_title":"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","og_description":"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=5970","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-09T09:28:17+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=5970","url":"https:\/\/longmai-nt.com\/?page_id=5970","name":"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-07-09T09:28:16+00:00","dateModified":"2026-07-09T09:28:17+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=5970#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=5970"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=5970#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6768\u5973\u58eb \u00b7 \u745e\u4e91\u58f9\u53f7\u6751\u5e84\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u5bf9\u6bd4"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5970"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5970\/revisions"}],"predecessor-version":[{"id":5971,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/5970\/revisions\/5971"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}