{"id":599,"date":"2026-05-12T01:19:39","date_gmt":"2026-05-11T17:19:39","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=599"},"modified":"2026-11-12T00:44:46","modified_gmt":"2026-11-11T16:44:46","slug":"%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a%c2%b7%e4%ba%94%e6%81%92%e7%b3%bb%e7%bb%9f%e9%a1%b9%e7%9b%ae%e6%a1%a3%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=599","title":{"rendered":"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66"},"content":{"rendered":"<div class=\"lm-geo\" data-cat=\"\u4e94\u6052\" data-layer=\"\u53f6\" data-step=\"4\" data-q=\"\u5929\u5e9c\u516c\u9986\u72ec\u680b\u522b\u5885\u6c34\u6c1f\u590d\u5408\u4e94\u6052\u7cfb\u7edf\u7684\u914d\u7f6e\u4ea4\u4ed8\u4e0e\u9a8c\u6536\u6863\u6848\"><\/div>\n<h3 class=\"wp-block-heading\">\u2014\u2014\u5173\u6ce8\u7528\u623720\u5e74\u4f7f\u7528\u8212\u9002\u3001\u7a33\u5b9a\u3001\u8282\u80fd\uff0c\u6863\u6848\u4e3a\u7528\u6237\u63d0\u4f9b\u670d\u52a1\u4fdd\u969c\u53ef\u89c6\u5316<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u6881\u603b<br \/><strong>\u9879\u76ee<\/strong>\uff1a\u5929\u5e9c\u516c\u9986\u00b7\u72ec\u680b\u522b\u5885<a href=\"https:\/\/longmai-nt.com\/?page_id=673\">\u4e94\u6052<\/a>\u7cfb\u7edf<br \/><strong>\u9879\u76ee\u8d1f\u8d23\u4eba<\/strong>\uff1a\u4f59\u6653\u73b2<br \/><strong>\u7b7e\u7ea6\u65e5\u671f<\/strong>\uff1a2024\u5e74<br \/><strong>\u6587\u6863\u7f16\u53f7<\/strong>\uff1aLY-2026-LIANG-002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u65f6\u95f4\u53e3\u5f84\u8bf4\u660e<\/strong>\uff1a\u672c\u9879\u76ee 2024 \u5e74\u7b7e\u7ea6\uff0c\u540c\u5e74\u5185\u5b8c\u6210\u73b0\u573a\u52d8\u6d4b\u3001\u7cfb\u7edf\u8bbe\u8ba1\u3001\u6750\u6599\u8fdb\u573a\u548c\u5b89\u88c5\uff1b2025 \u5e74 5 \u6708\u5b8c\u6210\u7cfb\u7edf\u8c03\u8bd5\u3001\u7ae3\u5de5\u9a8c\u6536\u4e0e\u4ea4\u4ed8\u6559\u5b66\uff0c\u9a8c\u6536\u5355\u4e0a\u7684\u300c2025.5\u300d\u662f\u4e1a\u4e3b\u4e0e\u9879\u76ee\u8d1f\u8d23\u4eba\u7b7e\u5b57\u65e5\u671f\uff1b2025 \u5e74 11 \u6708 26 \u65e5\u505a\u8fc7\u4e00\u6b21\u91c7\u6696\u53ca\u51c0\u5316\u6548\u679c\u56de\u8bbf\u3002\u8fd9\u4efd\u6863\u6848\u4e66\u548c\u540e\u9644\u7684\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u524d\u4e66\uff0c\u662f 2026 \u5e74 5 \u6708\u6309\u516c\u53f8 10 \u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u56de\u6eaf\u8865\u5f55\u7684\uff0c\u6240\u4ee5\u6863\u6848\u4e66\u7f16\u53f7\u91cc\u5e26 2026\u3002\u6587\u4e2d\u51fa\u73b0\u7684\u300c2026 \u5e74 5 \u6708\u300d\u90fd\u6307\u8865\u5f55\u65f6\u95f4\uff0c\u4e0d\u662f\u65bd\u5de5\u6216\u4ea4\u4ed8\u65f6\u95f4\uff1b\u65b9\u6848\u524d\u4e66\u539f\u4ef6\u51fa\u5177\u4e8e 2024 \u5e74 10 \u6708\uff0c\u843d\u6b3e\u5199\u7684\u662f\u539f\u4ef6\u65e5\u671f\u3002<\/p>\n<div class=\"wp-block-group has-small-font-size is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">\u3010\u76ee\u5f55\u3011<\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg01\">\u4e00\u3001\u9879\u76ee\u4fe1\u606f<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg011\">1.1 \u9879\u76ee\u6982\u51b5<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg012\">1.2 \u4e1a\u4e3b\u80cc\u666f\u4e0e\u7279\u6b8a\u9700\u6c42<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg02\">\u4e8c\u3001\u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg021\">2.1 \u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg022\">2.2 \u7b2c\u4e8c\u6b65\uff1a\u7cfb\u7edf\u8bbe\u8ba1\uff08\u542b\u8bbe\u8ba1\u53c2\u6570\u8868\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg023\">2.3 \u7b2c\u4e09\u6b65\uff1a\u6750\u6599\u8fdb\u573a\uff08\u542b\u8bbe\u5907\u6e05\u5355\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg024\">2.4 \u7b2c\u56db\u6b65\uff1a\u7cfb\u7edf\u5b89\u88c5<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg025\">2.5 \u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg026\">2.6 \u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536\uff08\u542b\u4e94\u6052\u6307\u6807\u5b9e\u6d4b\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg027\">2.7 +1\uff1a\u4ea4\u4ed8\u6559\u5b66\uff08\u542b\u64cd\u4f5c\u8981\u70b9\u901f\u67e5\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg028\">2.8 +2\uff1a\u552e\u540e\u4fdd\u969c\uff08\u542b\u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg03\">\u4e09\u3001\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg04\">\u56db\u3001\u5ba2\u6237\u53cd\u9988<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg041\">4.1 \u5ba2\u6237\u539f\u8bdd\u5b9e\u5f55<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg042\">4.2 \u6ee1\u610f\u5ea6\u8bc4\u5206<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg05\">\u4e94\u3001\u80fd\u8017\u8ddf\u8e2a\u6863\u6848<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg050\">5.0 \u8bf4\u660e\uff1a\u8d77\u70b9\u6570\u636e\u7684\u91c7\u96c6\u539f\u5219\uff08\u65b0\u589e\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg051\">5.1 \u6570\u636e\u57fa\u51c6\uff08\u8c03\u8bd5\u5f53\u65e5\u8bb0\u5f55\uff09- \u90e8\u5206\u6570\u636e\u7f3a\u5931\u8bf4\u660e<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg052\">5.2 \u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg053\">5.3 \u667a\u80fd\u7535\u8868\uff08B\u7ec4-\u4e24\u8054\u4f9b\u4e13\u5c5e\uff09- \u672a\u5b89\u88c5\u8bf4\u660e\uff08\u65b0\u589e\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg054\">5.4 AI\u8bca\u65ad\u8bb0\u5f55\uff08\u9884\u7559\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg06\">\u516d\u3001\u5ba2\u6237\u670d\u52a1\u8bb0\u5f55<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg061\">6.1 \u670d\u52a1\u8bb0\u5f55\u8868<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg062\">6.2 \u4f18\u5316\u5efa\u8bae\u8ddf\u8e2a\u8868\uff08\u65b0\u589e\uff09<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg07\">\u4e03\u3001\u9644\u4ef6\u6e05\u5355<\/a><\/h2>\n<h2 class=\"wp-block-heading has-small-font-size\"><a href=\"#tfgg08\">\u516b\u3001\u5ba2\u6237\u65b9\u6848\u524d\u4e66\uff08\u8bca\u65ad\u5206\u6790\u63d0\u51fa\u89e3\u51b3\u65b9\u6848\uff09<\/a><\/h2>\n<\/div>\n<h2 id=\"tfgg01\" class=\"wp-block-heading\">\u4e00\u3001\u9879\u76ee\u4fe1\u606f\uff1a\u5929\u5e9c\u516c\u9986<a href=\"https:\/\/longmai-nt.com\/?page_id=916\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/a>\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u9879\u76ee\u540d\u79f0<\/td>\n<td>\u72ec\u680b\u522b\u5885<a href=\"https:\/\/longmai-nt.com\/?page_id=916\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/a>\u4e94\u6052\u7cfb\u7edf\uff08\u6c34\u6c1f\u53cc\u7cfb\u7edf\u590d\u5408\u8bbe\u8ba1\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u9879\u76ee\u5730\u5740<\/td>\n<td>\u6210\u90fd\u00b7\u5929\u5e9c\u516c\u9986<\/td>\n<\/tr>\n<tr>\n<td>\u5efa\u7b51\u89c4\u6a21<\/td>\n<td>1-3\u697c\u516c\u533a\uff08\u7a7a\u8c03242.6\u33a1\/\u5730\u6696217.9\u33a1\uff09+ 4\u697c\u79c1\u533a\uff08\u7a7a\u8c03\u7ea650\u33a1\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u7c7b\u578b<\/td>\n<td>\u516c\u533a\uff1a\u6c34\u5885\u9002VF\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e94\u6052\uff08\u5929\u6c34\u5730\u6c34\uff09\/ \u79c1\u533a\uff1a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u4e94\u6052 \/ \u9152\u7a96\uff1a\u72ec\u7acb\u7cbe\u51c6\u63a7\u6e7f<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce\u7cfb\u7edf<\/td>\n<td>\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u4e00\u4f53\u673a \u00d7 4\u53f0\uff08350\u98ce\u91cf\u00d72 + 250\u98ce\u91cf\u00d72\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u7cfb\u7edf<\/td>\n<td>\u516c\u533a\uff1a\u667a\u5885\u5168\u611f2.0 \/ \u79c1\u533a\uff1a\u5168\u5c4b\u5168\u611f2.0<\/td>\n<\/tr>\n<tr>\n<td>\u4e1a\u4e3b\u80cc\u666f<\/td>\n<td>\u5317\u65b9\u4eba\uff0c\u9000\u4f11\u4f01\u4e1a\u5bb6\uff0c\u73b0\u5c45\u6210\u90fd\u517b\u8001\uff0c\u559c\u597d\u6536\u85cf\u540d\u9152<\/td>\n<\/tr>\n<tr>\n<td>\u7279\u6b8a\u9700\u6c42<\/td>\n<td>\u9152\u7a96\u5168\u5e74\u6052\u6e29\u6052\u6e7f\uff0850%\u00b15%\uff09\u3001\u8fdc\u7a0b\u667a\u63a7\uff08\u4e0d\u5e38\u4f4f\u6210\u90fd\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 id=\"tfgg02\" class=\"wp-block-heading\">\u4e8c\u3001\u65bd\u5de5\u6d41\u7a0b\uff1a<a href=\"https:\/\/longmai-nt.com\/#installation\">\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/a><\/h2>\n<h3 id=\"tfgg021\" class=\"wp-block-heading\">\u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u52d8\u6d4b\u65e5\u671f<\/td>\n<td>2024\u5e74<\/td>\n<\/tr>\n<tr>\n<td>\u52d8\u6d4b\u4eba\u5458<\/td>\n<td>\u4f59\u6653\u73b2<\/td>\n<\/tr>\n<tr>\n<td>\u52d8\u6d4b\u5185\u5bb9<\/td>\n<td>1-3\u697c\u516c\u533a\u9762\u79ef\/4\u697c\u79c1\u533a\u9762\u79ef\/\u9152\u7a96\u4f4d\u7f6e\u4e0e\u9762\u79ef\/\u5916\u673a\u4f4d\u6761\u4ef6\/\u7535\u6e90\u6761\u4ef6\/\u71c3\u6c14\u6761\u4ef6\/\u697c\u5c42\u4fdd\u6e29\/\u95e8\u7a97\u5bc6\u5c01\/\u5404\u623f\u95f4\u529f\u80fd\u786e\u8ba4<\/td>\n<\/tr>\n<tr>\n<td>\u52d8\u6d4b\u7ed3\u8bba<\/td>\n<td>\u516c\u533a\u9762\u79ef\u5927\u3001\u957f\u65f6\u95f4\u63a5\u5f85\uff0c\u9002\u5408\u6c34\u7cfb\u7edf\uff08\u51fa\u98ce\u67d4\u548c\u3001\u8fde\u63a5\u7387\u4e0d\u53d7\u9650\uff09\uff1b\u79c1\u533a\u9762\u79ef\u5c0f\u3001\u5076\u5c14\u4f7f\u7528\uff0c\u9002\u5408\u6c1f\u7cfb\u7edf\uff08\u54cd\u5e94\u5feb\u3001\u8282\u80fd\uff09\uff1b\u9152\u7a96\u9700\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce24h\u8fd0\u884c<\/td>\n<\/tr>\n<tr>\n<td><strong>\u73b0\u573a\u7167\u7247<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u73b0\u573a\u52d8\u6d4b\u7167\u7247\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-10 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"957\" height=\"718\" data-id=\"437\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143257.jpg\" alt=\"\u6881\u603b\u5929\u5e9c\u516c\u9986\u5916\u673a\u5b9a\u4f4d\" class=\"wp-image-437\" style=\"width:606px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143257.jpg 957w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143257-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143257-768x576.jpg 768w\" sizes=\"auto, (max-width: 957px) 100vw, 957px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"951\" height=\"713\" data-id=\"416\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143239.jpg\" alt=\"\u6881\u603b\u5929\u5e9c\u516c\u9986\u5ba4\u5185\u673a\u5b9a\u4f4d\" class=\"wp-image-416\" style=\"width:602px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143239.jpg 951w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143239-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143239-768x576.jpg 768w\" sizes=\"auto, (max-width: 951px) 100vw, 951px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"932\" height=\"699\" data-id=\"420\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143250.jpg\" alt=\"\u6881\u603b\u5929\u5e9c\u516c\u9986\u7ba1\u9053\u5b9a\u4f4d\" class=\"wp-image-420\" style=\"width:598px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143250.jpg 932w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143250-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143250-768x576.jpg 768w\" sizes=\"auto, (max-width: 932px) 100vw, 932px\" \/><\/figure>\n<\/figure>\n<\/div>\n<h3 id=\"tfgg022\" class=\"wp-block-heading\">\u7b2c\u4e8c\u6b65\uff1a\u7cfb\u7edf\u8bbe\u8ba1<\/h3>\n<p class=\"wp-block-paragraph\">\u8be6\u7ec6\u7cfb\u7edf\u8bbe\u8ba1\uff0c\u4e3a\u7528\u6237\u5206\u6790\u8bca\u65ad\u9700\u6c42\u75db\u70b9\uff0c\u63d0\u4f9b\u591a\u79cd\u53ef\u9009\u89e3\u51b3\u65b9\u6848\u89c1<a href=\"#tfgg08\">\u65b9\u6848\u524d\u4e66<\/a>\uff0c\u9a8c\u8bc1\u8fed\u4ee3\u89c1<a href=\"#tfgg06\">\u5ba2\u6237\u670d\u52a1\u8bb0\u5f55<\/a>\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5b8c\u6210\u65e5\u671f<\/td>\n<td>2024\u5e74<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u4eba\u5458<\/td>\n<td>\u4f59\u6653\u73b2<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u5185\u5bb9<\/td>\n<td>\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97\uff08GB 50736-2012\uff09\/\u6c34\u529b\u8ba1\u7b97\/\u51b7\u5a92\u7ba1\u8def\u8bbe\u8ba1\/\u65b0\u98ce\u7ba1\u8def\u8bbe\u8ba1\/\u4e94\u6052\u6307\u6807\u8bbe\u5b9a\/\u53cc\u7cfb\u7edf\u63a7\u5236\u903b\u8f91\u8bbe\u8ba1\/\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\u65b9\u6848<\/td>\n<\/tr>\n<tr>\n<td>\u6838\u5fc3\u8bbe\u8ba1\u51b3\u7b56<\/td>\n<td>\u516c\u533a\u6c34\u7cfb\u7edf+\u79c1\u533a\u6c1f\u7cfb\u7edf\u2014\u2014\u6c34\u6c1f\u590d\u5408\u8bbe\u8ba1\u3002\u516c\u533a10\u53f0\u5185\u673a\u7528\u6c34\u7cfb\u7edf\uff08\u51fa\u98ce15-20\u2103\u3001\u65e0\u98ce\u611f\u3001\u9002\u5408\u957f\u65f6\u95f4\u63a5\u5f85\uff09\uff0c\u79c1\u533a3\u53f0\u5185\u673a\u7528\u6c1f\u7cfb\u7edf\uff08\u51fa\u98ce7-12\u2103\u3001\u5236\u51b7\u5feb\u3001\u9002\u5408\u5076\u5c14\u4f7f\u7528\uff09\uff0c\u53cc\u7cfb\u7edf\u4e92\u4e3a\u5907\u4efd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ba1\u8def\u8bbe\u8ba1\u56fe<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165CAD\u7ba1\u8def\u8d70\u5411\u56fe\uff09<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5206\u96c6\u6c34\u5668\u5b9a\u4f4d\u56fe<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u73b0\u573a\u6807\u6ce8\u7167\u7247\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u516c\u533a\uff081-3\u697c\uff09<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u79c1\u533a\uff084\u697c\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u7a7a\u8c03\u9762\u79ef<\/td>\n<td>242.6\u33a1<\/td>\n<td>\u7ea650\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u9762\u79ef<\/td>\n<td>217.9\u33a1<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u8d1f\u8377\u6807\u51c6<\/td>\n<td>150-220W\/\u33a1\uff08\u522b\u5885\uff09<\/td>\n<td>80-120W\/\u33a1\uff08\u9ad8\u5c42\u6807\u51c6\uff0c\u9876\u5c42\u4fee\u6b63\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u8d85\u914d\u7387<\/td>\n<td>110%-130%<\/td>\n<td>90%-110%<\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u6307\u6807\u5bf9\u7167\u6807\u51c6<\/td>\n<td>T\/CAS 1009-2025<\/td>\n<td>\u540c\u5de6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-11 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"415\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143500-1-1024x768.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u4e2d\u592e\u7a7a\u8c03\u5ba4\u5185\u8bbe\u8ba1\" class=\"wp-image-415\" style=\"width:467px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143500-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143500-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143500-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143500-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143500-1-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"409\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143515-1024x768.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u5730\u6696\u7cfb\u7edf\u8bbe\u8ba1\" class=\"wp-image-409\" style=\"width:467px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143515-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143515-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143515-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143515-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143515.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"413\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143507-1024x768.jpg\" alt=\"\" class=\"wp-image-413\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143507-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143507-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143507-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143507-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143507-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"411\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143518-1024x768.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u5730\u6696\u65bd\u5de5\u56fe1\" class=\"wp-image-411\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143518-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143518-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143518-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143518-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143518.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"414\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143530-1024x768.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u5730\u6696\u65bd\u5de5\u56fe2\" class=\"wp-image-414\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143530-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143530-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143530-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143530-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143530.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"412\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143545-1024x768.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u65b0\u98ce\u8bbe\u8ba11\" class=\"wp-image-412\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143545-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143545-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143545-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143545-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143545-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n<\/div>\n<h3 id=\"tfgg023\" class=\"wp-block-heading\">\u7b2c\u4e09\u6b65\uff1a\u6750\u6599\u8fdb\u573a<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8fdb\u573a\u65e5\u671f<\/td>\n<td>2024\u5e74<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u4eba\u5458<\/td>\n<td>\u4e1a\u4e3b\/\u65bd\u5de5\u8d1f\u8d23\u4eba<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u5185\u5bb9<\/td>\n<td>\u4e3b\u673a\/\u5185\u673a\/\u65b0\u98ce\/\u6c34\u6cf5\/\u76d8\u7ba1\/\u4e3b\u7ba1\/\u5206\u96c6\u6c34\u5668\/\u6e29\u63a7\u5668\/\u4fdd\u6e29\u677f\/\u53cd\u5c04\u819c\/\u94dc\u7ba1\/\u8f85\u6750\u7684\u54c1\u724c\/\u578b\u53f7\/\u6570\u91cf\u6838\u5bf9<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u7ed3\u679c<\/td>\n<td>\u5168\u90e8\u6838\u5bf9\u65e0\u8bef\uff0c\u4e1a\u4e3b\u7b7e\u5b57\u786e\u8ba4<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6750\u6599\u7167\u7247<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u6750\u6599\u8fdb\u573a\u5168\u666f\u7167\u7247+\u54c1\u724c\u6807\u7b7e\u7279\u5199\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6750\u6599\u6e05\u5355\uff08\u8ba1\u6570\uff0c\u4e0d\u8ba1\u4ef7\uff09\uff1a<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u516c\u533a\u2014\u2014\u6c34\u7cfb\u7edf\u4e94\u6052\uff081-3\u697c\uff09<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7c7b\u522b<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\/\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u70ed\u6e90<\/td>\n<td>\u4e3b\u673a<\/td>\n<td>\u65e5\u7acb\u6c34\u5885\u9002VF<\/td>\n<td>RAS-280FEWNY1Q\/M<\/td>\n<td>1<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u672b\u7aef<\/td>\n<td>\u5185\u673a<\/td>\n<td>\u96f6\u8d8aDC\u98ce\u673a\u76d8\u7ba1<\/td>\n<td>\u5e26PE\u51c0\u5316\u6a21\u5757<\/td>\n<td>10<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce<\/td>\n<td>\u9664\u6e7f\u65b0\u98ce<\/td>\n<td>\u5929\u51c0<\/td>\n<td>350\u98ce\u91cf<\/td>\n<td>2<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce<\/td>\n<td>\u9664\u6e7f\u65b0\u98ce<\/td>\n<td>\u5929\u51c0<\/td>\n<td>250\u98ce\u91cf<\/td>\n<td>1<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236<\/td>\n<td>\u667a\u63a7\u7cfb\u7edf<\/td>\n<td>\u667a\u5885\u5168\u611f2.0<\/td>\n<td>\u2014<\/td>\n<td>1<\/td>\n<td>\u5957<\/td>\n<\/tr>\n<tr>\n<td>\u8f93\u914d<\/td>\n<td>\u4e3b\u7ba1<\/td>\n<td>PPR S3.2<\/td>\n<td>\u6309\u6c34\u529b\u8ba1\u7b97\u9009\u578b<\/td>\n<td>\u6309\u9700<\/td>\n<td>\u7c73<\/td>\n<\/tr>\n<tr>\n<td>\u8f93\u914d<\/td>\n<td>\u5206\u96c6\u6c34\u5668<\/td>\n<td>\u94dc\u8d28\u4e00\u4f53\u953b\u9020<\/td>\n<td>\u6309\u56de\u8def\u6570<\/td>\n<td>\u6309\u9700<\/td>\n<td>\u5957<\/td>\n<\/tr>\n<tr>\n<td>\u672b\u7aef<\/td>\n<td>\u5730\u6696\u76d8\u7ba1<\/td>\n<td>PE-RT\u963b\u6c27\u7ba1<\/td>\n<td>De20<\/td>\n<td>\u6309\u9700<\/td>\n<td>\u7c73<\/td>\n<\/tr>\n<tr>\n<td>\u8f85\u6750<\/td>\n<td>\u4fdd\u6e29\u677f\/\u53cd\u5c04\u819c\/\u8fb9\u754c\u4fdd\u6e29\u6761\u7b49<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u6309\u9700<\/td>\n<td>\u33a1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u79c1\u533a\u2014\u2014\u6c1f\u7cfb\u7edf\u4e94\u6052\uff084\u697c\uff09<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7c7b\u522b<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\/\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u70ed\u6e90<\/td>\n<td>\u4e3b\u673a<\/td>\n<td>\u65e5\u7acb\u667a\u4eab<\/td>\n<td>RAS-140FSPUNQ<\/td>\n<td>1<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u672b\u7aef<\/td>\n<td>\u5185\u673a<\/td>\n<td>\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td>\n<td>\u5e26\u81ea\u6e05\u6d01+PE\u51c0\u5316<\/td>\n<td>3<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce<\/td>\n<td>\u9664\u6e7f\u65b0\u98ce<\/td>\n<td>\u5929\u51c0<\/td>\n<td>250\u98ce\u91cf<\/td>\n<td>1<\/td>\n<td>\u53f0<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236<\/td>\n<td>\u667a\u63a7\u7cfb\u7edf<\/td>\n<td>\u5168\u5c4b\u5168\u611f2.0<\/td>\n<td>\u2014<\/td>\n<td>1<\/td>\n<td>\u5957<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-12 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"896\" height=\"672\" data-id=\"436\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143306.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u6c34\u5885\u9002\u4e3b\u673a\u8fdb\u573a\u9a8c\u6536\" class=\"wp-image-436\" style=\"width:602px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143306.jpg 896w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143306-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143306-768x576.jpg 768w\" sizes=\"auto, (max-width: 896px) 100vw, 896px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"961\" height=\"721\" data-id=\"431\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143312.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u6c34\u673a\u6750\u6599\u6e05\u5355\u9a8c\u6536\" class=\"wp-image-431\" style=\"width:606px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143312.jpg 961w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143312-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143312-768x576.jpg 768w\" sizes=\"auto, (max-width: 961px) 100vw, 961px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"941\" height=\"706\" data-id=\"432\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143353-1.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u5730\u6696\u5206\u96c6\u6c34\u5668\u68c0\u67e5\" class=\"wp-image-432\" style=\"width:598px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143353-1.jpg 941w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143353-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143353-1-768x576.jpg 768w\" sizes=\"auto, (max-width: 941px) 100vw, 941px\" \/><\/figure>\n<\/figure>\n<\/div>\n<h3 id=\"tfgg024\" class=\"wp-block-heading\">\u7b2c\u56db\u6b65\uff1a\u7cfb\u7edf\u5b89\u88c5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u65bd\u5de5\u65e5\u671f<\/td>\n<td>2024\u5e74<\/td>\n<\/tr>\n<tr>\n<td>\u65bd\u5de5\u4eba\u5458<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u65bd\u5de5\u5185\u5bb9<\/td>\n<td><strong>\u516c\u533a\u6c34\u7cfb\u7edf<\/strong>\uff1a\u4e3b\u673a\u5c31\u4f4d\u2192\u6c34\u6cf5\u5b89\u88c5\u2192\u4e3b\u7ba1\u94fa\u8bbe\uff08PPR S3.2\u70ed\u7194\u8fde\u63a5\uff0c\u9632\u7f29\u5f84\u5de5\u827a\uff09\u2192\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u2192\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08De20\u963b\u6c27\u7ba1\/200mm\u95f4\u8ddd\uff09\u2192\u96f6\u8d8a\u98ce\u76d8\u540a\u88c5\u2192\u98ce\u7ba1\u8fde\u63a5\u2192\u5929\u51c0\u65b0\u98ce\u5b89\u88c5<br \/><strong>\u79c1\u533a\u6c1f\u7cfb\u7edf<\/strong>\uff1a\u4e3b\u673a\u5c31\u4f4d\u2192\u94dc\u7ba1\u710a\u63a5\uff08\u5168\u7a0b\u5145\u6c2e\u4fdd\u62a4\uff09\u2192\u5206\u6b67\u7ba1\u5b89\u88c5\u2192\u4fdd\u538b\u6d4b\u8bd5\uff084.0MPa\/24h\uff09\u2192\u5185\u673a\u540a\u88c5\u2192\u5929\u51c0\u65b0\u98ce\u5b89\u88c5<br \/><strong>\u5168\u697c<\/strong>\uff1a\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22651%\/\u91d1\u5c5e\u63a5\u5934\u4e09\u9053\u5bc6\u5c01\u5de5\u827a\uff08\u751f\u6599\u5e26+\u538c\u6c27\u80f6+\u9ebb\u4e1d\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u538b\u8bb0\u5f55<\/td>\n<td>\u6253\u538b\u538b\u529b___MPa\uff0c\u4fdd\u538b\u65f6\u957f___\u5c0f\u65f6\uff0c\u538b\u964d___MPa<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u7ed3\u679c<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>\u65bd\u5de5\u7167\u7247<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u65bd\u5de5\u8fc7\u7a0b\u7167\u7247\u2014\u2014\u94dc\u7ba1\u710a\u63a5\/\u7ba1\u9053\u94fa\u8bbe\/\u5185\u673a\u540a\u88c5\/\u4fdd\u538b\u6d4b\u8bd5\u538b\u529b\u8868\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-13 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"866\" height=\"649\" data-id=\"408\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152423_204_336.jpg\" alt=\"\" class=\"wp-image-408\" style=\"width:602px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152423_204_336.jpg 866w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152423_204_336-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152423_204_336-768x576.jpg 768w\" sizes=\"auto, (max-width: 866px) 100vw, 866px\" \/><\/figure>\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"397\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143330-1024x768.jpg\" alt=\"\" class=\"wp-image-397\" style=\"width:606px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143330-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143330-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143330-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143330.jpg 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"805\" height=\"604\" data-id=\"407\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152424_205_336.jpg\" alt=\"\" class=\"wp-image-407\" style=\"width:598px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152424_205_336.jpg 805w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152424_205_336-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504152424_205_336-768x576.jpg 768w\" sizes=\"auto, (max-width: 805px) 100vw, 805px\" \/><\/figure>\n<\/figure>\n<\/div>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u65bd\u5de5\u5de5\u827a\u63d0\u793a<\/strong>\uff1a\u6c34\u7cfb\u7edfPPR\u7ba1\u70ed\u7194\u8fde\u63a5\u65f6\u4e25\u683c\u63a7\u5236\u6e29\u5ea6\u548c\u65f6\u95f4\uff0c\u9632\u6b62\u7f29\u5f84\u3002\u94dc\u7ba1\u710a\u63a5\u5168\u7a0b\u5145\u6c2e\u6c14\u4fdd\u62a4\uff0c\u9632\u6b62\u5185\u58c1\u6c27\u5316\u4ea7\u751f\u6742\u8d28\u3002\u6240\u6709\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u5b58\u6863\u3002<\/p>\n<\/blockquote>\n<h3 id=\"tfgg025\" class=\"wp-block-heading\">\u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8c03\u8bd5\u65e5\u671f<\/td>\n<td>2025\u5e745\u6708<\/td>\n<\/tr>\n<tr>\n<td>\u8c03\u8bd5\u4eba\u5458<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u8c03\u8bd5\u5185\u5bb9<\/td>\n<td><strong>\u516c\u533a\u6c34\u7cfb\u7edf<\/strong>\uff1a\u4e3b\u673a\u53d8\u9891\u8fd0\u884c\u6d4b\u8bd5\/\u6c34\u6cf5\u6d41\u91cf\u8c03\u8282\/\u5404\u56de\u8def\u6c34\u529b\u5e73\u8861\u8c03\u8282\/\u5730\u6696\u5347\u6e29\u6d4b\u8bd5\/\u96f6\u8d8a\u98ce\u76d8\u5236\u51b7\/\u5236\u70ed\u6d4b\u8bd5\/\u566a\u97f3\u6d4b\u8bd5<br \/><strong>\u79c1\u533a\u6c1f\u7cfb\u7edf<\/strong>\uff1a\u4e3b\u673a\u53d8\u9891\u8fd0\u884c\u6d4b\u8bd5\/\u51b7\u5a92\u8ffd\u52a0\u91cf\u786e\u8ba4\/\u5185\u673a\u5236\u51b7\/\u5236\u70ed\u6d4b\u8bd5\/\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\u529f\u80fd\u6d4b\u8bd5\/\u566a\u97f3\u6d4b\u8bd5<br \/><strong>\u65b0\u98ce\u7cfb\u7edf<\/strong>\uff1a\u56db\u53f0\u5929\u51c0\u72ec\u7acb\u8fd0\u884c\u6d4b\u8bd5\/\u9664\u6e7f\u529f\u80fd\u6d4b\u8bd5\/\u5168\u70ed\u56de\u6536\u6548\u7387\u9a8c\u8bc1\/\u4e94\u7ef4\u76d1\u6d4b\u6570\u636e\u6821\u51c6\uff08\u6e29\/\u6e7f\/PM2.5\/CO\u2082\/TVOC\uff09<br \/><strong>\u63a7\u5236\u7cfb\u7edf<\/strong>\uff1a\u667a\u5885\u5168\u611f2.0\u573a\u666f\u6a21\u5f0f\u6d4b\u8bd5\uff08\u4f1a\u5ba2\/\u805a\u9910\/\u9152\u7a96\/\u7761\u7720\/\u79bb\u5bb6\uff09\/\u5168\u5c4b\u5168\u611f2.0 AI\u81ea\u5b66\u4e60\u542f\u52a8\/APP\u8fdc\u7a0b\u63a7\u5236\u6d4b\u8bd5<br \/><strong>\u8054\u52a8\u6d4b\u8bd5<\/strong>\uff1a\u5ba4\u6e29\u8fbe\u6807\u2192\u6c34\u6cf5\u505c\u673a\u2192\u4e3b\u673a\u505c\u673a\uff08\u675c\u7edd\u65e0\u6548\u4ea7\u70ed\uff09\/CO\u2082\u8d85\u6807\u2192\u65b0\u98ce\u81ea\u52a8\u52a0\u5927\u6362\u6c14\u91cf\/\u6e7f\u5ea6\u8d85\u6807\u2192\u9664\u6e7f\u65b0\u98ce\u72ec\u7acb\u542f\u52a8<\/td>\n<\/tr>\n<tr>\n<td>\u8c03\u8bd5\u6570\u636e<\/td>\n<td>\u5ba4\u6e29_27__\u2103\/\u51fa\u98ce\u53e3\u6e29\u5ea6_24.3_\u2103\/\u7532\u919b__0_ppm\/CO\u2082__588_ppm\/PM2.5_25__\u03bcg\/m\u00b3\/\u6e7f\u5ea6_48_%\/\u566a\u97f3_24__dB<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u7ed3\u679c<\/td>\n<td>\u4e94\u6052\u6307\u6807\u5168\u90e8\u8fbe\u6807<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8c03\u8bd5\u7167\u7247<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u96c6\u63a7\u5c4f\u4e94\u7ef4\u6570\u636e\u663e\u793a\u56fe\/\u5404\u623f\u95f4\u6e29\u6e7f\u5ea6\u5b9e\u6d4b\u7167\u7247\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-14 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"988\" data-id=\"440\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504164838_305_31-1024x988.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u6c34\u5885\u9002\u4e3b\u673a\u8c03\u8bd5\" class=\"wp-image-440\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504164838_305_31-1024x988.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504164838_305_31-300x290.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504164838_305_31-768x741.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504164838_305_31.jpg 1153w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"423\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143436-1024x768.jpg\" alt=\"\u5929\u5e9c\u516c\u9986\u5929\u6c1f\u5730\u6c34\u5168\u5c4b\u5168\u611f\u8c03\u8bd5\" class=\"wp-image-423\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143436-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143436-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143436-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143436.jpg 1242w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"891\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9a8c\u65361-1-1024x768.jpg\" alt=\"\" class=\"wp-image-891\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9a8c\u65361-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9a8c\u65361-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9a8c\u65361-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9a8c\u65361-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9a8c\u65361-1-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n<\/div>\n<h3 id=\"tfgg026\" class=\"wp-block-heading\">\u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u9a8c\u6536\u65e5\u671f<\/td>\n<td>2025\u5e745\u6708<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u4eba\u5458<\/td>\n<td>\u6881\u603b\/\u4f59\u6653\u73b2<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u5185\u5bb9<\/td>\n<td>\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c\/\u4e94\u6052\u6307\u6807\u5b9e\u6d4b\/\u5404\u623f\u95f4\u6548\u679c\u786e\u8ba4\/\u9152\u7a96\u6052\u6e29\u6052\u6e7f\u9a8c\u8bc1\/APP\u8fdc\u7a0b\u63a7\u5236\u6f14\u793a<\/td>\n<\/tr>\n<tr>\n<td>\u9a8c\u6536\u7ed3\u8bba<\/td>\n<td>\u4e94\u6052\u6307\u6807\u5168\u90e8\u8fbe\u6807\uff0c\u5ba2\u6237\u6ee1\u610f\u5ea610\u5206<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9a8c\u6536\u7167\u7247<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u7ae3\u5de5\u9a8c\u6536\u73b0\u573a\u7167\u7247\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u4e94\u6052\u6307\u6807\u5b9e\u6d4b\u6570\u636e<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u76ee\u6807<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4ea4\u4ed8\u5b9e\u6d4b<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ed3\u8bba<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u6052\u6e29\uff08\u590f\u5b63\uff09<\/td>\n<td>\u516c\u533a22-24\u2103\/\u79c1\u533a20-22\u2103<\/td>\n<td>\u8fbe\u6807<\/td>\n<td>\u2705<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e7f<\/td>\n<td>40%-70%\uff08\u5168\u5e74\uff09<\/td>\n<td>48%<\/td>\n<td>\u2705<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6c27<\/td>\n<td>CO\u2082 \u2264 800ppm<\/td>\n<td>\u2264588ppm<\/td>\n<td>\u2705 \u4f18\u4e8e\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6d01<\/td>\n<td>PM2.5 \u2264 25\u03bcg\/m\u00b3\uff0c\u7532\u919b0\uff0cVOC\u4e3a0<\/td>\n<td>\u226425\u03bcg\/m\u00b3\uff0c\u7532\u919b0\uff0cVOC\u4e3a0<\/td>\n<td>\u2705 \u4f18\u4e8e\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u9759<\/td>\n<td>\u5367\u5ba4 \u2264 30dB<\/td>\n<td>\u226426dB\uff08\u516c\u533a\uff09\/\u226424dB\uff08\u4e3b\u5367\uff09<\/td>\n<td>\u2705 \u4f18\u4e8e\u6807\u51c6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 id=\"tfgg027\" class=\"wp-block-heading\">+1\uff1a\u4ea4\u4ed8\u6559\u5b66<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u6559\u5b66\u65e5\u671f<\/td>\n<td>2025\u5e745\u6708<\/td>\n<\/tr>\n<tr>\n<td>\u6559\u5b66\u4eba\u5458<\/td>\n<td>\u4f59\u6653\u73b2<\/td>\n<\/tr>\n<tr>\n<td>\u6559\u5b66\u5185\u5bb9<\/td>\n<td>\u2460\u53cc\u7cfb\u7edf\u5f00\u5173\u673a\u53ca\u6e29\u5ea6\u8bbe\u5b9a\uff08\u516c\u533a\u6c34\u7cfb\u7edf\/\u79c1\u533a\u6c1f\u7cfb\u7edf\u72ec\u7acb\u64cd\u4f5c\uff09\uff1b\u2461\u573a\u666f\u6a21\u5f0f\u5207\u6362\uff08\u4f1a\u5ba2\/\u805a\u9910\/\u9152\u7a96\/\u7761\u7720\/\u79bb\u5bb6\uff09\uff1b\u2462APP\u8fdc\u7a0b\u63a7\u5236\u64cd\u4f5c\uff08\u65e5\u7acb\u667a\u5bb6APP\uff09\uff1b\u2463\u65b0\u98ce\u9664\u6e7f\u8bbe\u5b9a\uff08\u6e7f\u5ea6\u76ee\u6807\u503c\/\u8fd0\u884c\u6a21\u5f0f\uff09\uff1b\u2464\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\u64cd\u4f5c\uff1b\u2465\u7cfb\u7edf\u8865\u6c34\u64cd\u4f5c\uff1b\u2466\u51ac\u5b63\u9632\u51bb\u8bbe\u7f6e\uff08\u957f\u671f\u79bb\u5bb6\u6a21\u5f0f\uff09\uff1b\u2467\u6ee4\u7f51\u6e05\u6d17\u5468\u671f\u63d0\u9192<\/td>\n<\/tr>\n<tr>\n<td>\u6559\u5b66\u786e\u8ba4<\/td>\n<td>\u4e1a\u4e3b\u5df2\u72ec\u7acb\u5b8c\u6210\u4e0a\u8ff0\u64cd\u4f5c\uff0c\u786e\u8ba4\u638c\u63e1 \u25a1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6559\u5b66\u73b0\u573a\u7167\u7247<\/strong><\/td>\n<td><em>\uff08\u6b64\u5904\u63d2\u5165\u4ea4\u4ed8\u6559\u5b66\u73b0\u573a\u7167\u7247\uff09<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u6559\u5b66\u8981\u70b9\u901f\u67e5\uff08\u4e94\u6052\u7cfb\u7edf\u4e13\u7528\uff09<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8981\u70b9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u516c\u533a\u6c34\u7cfb\u7edf\u6c34\u6e29<\/td>\n<td>\u590f\u5b63\u4f9b\u6c347-12\u2103\uff0c\u51ac\u5b63\u4f9b\u6c3435-45\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u79c1\u533a\u6c1f\u7cfb\u7edf\u8bbe\u5b9a<\/td>\n<td>\u590f\u5b6324-26\u2103\uff0c\u51ac\u5b6320-22\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u9152\u7a96\u6a21\u5f0f<\/td>\n<td>\u6e29\u5ea618-22\u2103\/\u6e7f\u5ea650%\u00b15%\/24\u5c0f\u65f6\u8fd0\u884c<\/td>\n<\/tr>\n<tr>\n<td>\u79bb\u5bb6\u6a21\u5f0f<\/td>\n<td>\u516c\u533a\u5173\u3001\u79c1\u533a\u5173\u3001\u9152\u7a96\u4fdd\u6301\/\u9632\u51bb\u6a21\u5f0f\u542f\u7528<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce\u9664\u6e7f\u8bbe\u5b9a<\/td>\n<td>\u6885\u96e8\u5b63\u6e7f\u5ea6\u8bbe\u5b9a50%\/\u8fc7\u6e21\u5b63\u53ef\u8c03\u9ad8\u81f355%<\/td>\n<\/tr>\n<tr>\n<td>APP\u8fdc\u7a0b<\/td>\n<td>\u65e5\u7acb\u667a\u5bb6APP\u53ef\u67e5\u770b\u5168\u5c4b\u6e29\u6e7f\u5ea6\/\u8c03\u8282\/\u63a5\u6536\u62a5\u8b66<\/td>\n<\/tr>\n<tr>\n<td>\u957f\u671f\u79bb\u5bb6<\/td>\n<td>\u4fdd\u6301\u9505\u7089\u901a\u7535\u901a\u6c14\uff0c\u542f\u7528\u9632\u51bb\u6a21\u5f0f<\/td>\n<\/tr>\n<tr>\n<td>\u6ee4\u7f51\u6e05\u6d17<\/td>\n<td>\u65b0\u98ce\u6ee4\u7f513-6\u4e2a\u6708\u66f4\u6362\uff0c\u5185\u673a\u6ee4\u7f51\u6bcf\u6708\u6e05\u6d17<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 id=\"tfgg028\" class=\"wp-block-heading\">+2\uff1a\u552e\u540e\u4fdd\u969c<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u969c\u9879<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8bbe\u5907\u8d28\u4fdd<\/td>\n<td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd<\/td>\n<\/tr>\n<tr>\n<td>\u5de5\u7a0b\u8d28\u4fdd<\/td>\n<td>5\u5e74\u8d77<\/td>\n<\/tr>\n<tr>\n<td>\u4e09\u65b9\u8054\u4fdd<\/td>\n<td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td>\n<\/tr>\n<tr>\n<td>\u4f1a\u5458\u670d\u52a1<\/td>\n<td>\u5e74\u5ea6\u68c0\u6d4b\/\u7ef4\u4fdd\u63d0\u9192\/\u4f18\u5148\u54cd\u5e94\/\u670d\u52a1\u6298\u6263\/\u8fdc\u7a0b\u8bca\u65ad<\/td>\n<\/tr>\n<tr>\n<td>\u7d27\u6025\u62a5\u4fee<\/td>\n<td><em><a href=\"tel:4008601111\">\u65e5\u7acb\u5b98\u65b9400\u7535\u8bdd<\/a><\/em> <a href=\"tel:13183879308\">\u9f99\u8109\u6696\u901a\u552e\u540e\u7535\u8bdd<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355\uff08\u4e94\u6052\u7cfb\u7edf\u4e13\u7528\uff09<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u4fdd\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5468\u671f<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u65b0\u98ce\u6ee4\u7f51\u66f4\u6362<\/td>\n<td>3-6\u4e2a\u6708<\/td>\n<td>HEPA\u6ee4\u7f51\/\u6d3b\u6027\u70ad\u6ee4\u7f51<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a\u6ee4\u7f51\u6e05\u6d17<\/td>\n<td>\u6bcf\u6708<\/td>\n<td>\u6e05\u6d17\u56de\u98ce\u53e3\u6ee4\u7f51<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u7cfb\u7edf\u6c34\u8d28\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5PH\u503c\/\u6d4a\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5\u8fd0\u884c\u68c0\u6d4b<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u566a\u97f3\/\u632f\u52a8\/\u7535\u6d41<\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u4f20\u611f\u5668\u6821\u51c6<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u6e29\u6e7f\u5ea6\/CO\u2082\/PM2.5\u4f20\u611f\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u5a92\u538b\u529b\u68c0\u6d4b<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u662f\u5426\u6709\u6cc4\u6f0f<\/td>\n<\/tr>\n<tr>\n<td>\u9664\u6e7f\u6a21\u5757\u6e05\u6d17<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u51b7\u51dd\u6c34\u76d8\/\u6362\u70ed\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u7ba1\u6c14\u5bc6\u6027\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u6f0f\u98ce\u70b9<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u8054\u8c03\u6d4b\u8bd5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c\u6d4b\u8bd5<\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u672b\u7aef\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u6709\u65e0\u7ed3\u9732\u75d5\u8ff9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 id=\"tfgg03\" class=\"wp-block-heading\">\u4e09\u3001\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9a8c\u6536\u9879<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5b9e\u6d4b\u7ed3\u679c<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ed3\u8bba<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u516c\u533a\u6c34\u7cfb\u7edf\u5236\u51b7<\/td>\n<td>\u51fa\u98ce\u6e29\u5ea615-20\u2103\/\u5ba4\u6e29\u8fbe\u6807<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u516c\u533a\u6c34\u7cfb\u7edf\u5236\u70ed<\/td>\n<td>\u5730\u6696\u5347\u6e29\u6b63\u5e38\/\u5ba4\u6e29\u8fbe\u6807<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u79c1\u533a\u6c1f\u7cfb\u7edf\u5236\u51b7<\/td>\n<td>\u51fa\u98ce\u6e29\u5ea67-12\u2103\/\u5ba4\u6e29\u8fbe\u6807<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u79c1\u533a\u6c1f\u7cfb\u7edf\u5236\u70ed<\/td>\n<td>\u5730\u6696\u5347\u6e29\u6b63\u5e38\/\u5ba4\u6e29\u8fbe\u6807<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e29\uff08\u5168\u697c\uff09<\/td>\n<td>\u8bbe\u8ba1\u503c\u00b11\u2103<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e7f\uff08\u5168\u697c\uff09<\/td>\n<td>40%-60%\/\u9152\u7a9650%\u00b15%<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6c27<\/td>\n<td>CO\u2082\u2264800ppm<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6d01<\/td>\n<td>PM2.5\u226425\u03bcg\/m\u00b3<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u9759<\/td>\n<td>\u516c\u533a\u226435dB\/\u5367\u5ba4\u226430dB<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce\u9664\u6e7f\u72ec\u7acb\u8fd0\u884c<\/td>\n<td>\u56db\u53f0\u5929\u51c0\u6b63\u5e38\u8fd0\u884c<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u667a\u5885\u5168\u611f2.0\u573a\u666f\u6a21\u5f0f<\/td>\n<td>\u4f1a\u5ba2\/\u805a\u9910\/\u9152\u7a96\/\u7761\u7720\/\u79bb\u5bb6<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u5168\u5c4b\u5168\u611f2.0 AI\u81ea\u5b66\u4e60<\/td>\n<td>\u542f\u52a8\u6b63\u5e38<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>APP\u8fdc\u7a0b\u63a7\u5236<\/td>\n<td>\u624b\u673a\u7aef\u53ef\u67e5\u770b\/\u8c03\u8282\/\u63a5\u6536\u62a5\u8b66<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f<\/td>\n<td>24h\u8fd0\u884c\/\u6e7f\u5ea650%\u00b15%<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<tr>\n<td>\u4ea4\u4ed8\u6559\u5b66<\/td>\n<td>\u4e1a\u4e3b\u72ec\u7acb\u5b8c\u6210\u57fa\u672c\u64cd\u4f5c<\/td>\n<td><\/td>\n<td>\u25a1\u901a\u8fc7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-15 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"750\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u8c03\u8bd5\u4e00\u5bf9\u4e00\u6559\u5b66-1024x768.jpg\" alt=\"\" class=\"wp-image-750\" style=\"width:602px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u8c03\u8bd5\u4e00\u5bf9\u4e00\u6559\u5b66-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u8c03\u8bd5\u4e00\u5bf9\u4e00\u6559\u5b66-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u8c03\u8bd5\u4e00\u5bf9\u4e00\u6559\u5b66-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u8c03\u8bd5\u4e00\u5bf9\u4e00\u6559\u5b66.jpg 1290w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"956\" height=\"717\" data-id=\"433\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143327.jpg\" alt=\"\" class=\"wp-image-433\" style=\"width:606px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143327.jpg 956w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143327-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504143327-768x576.jpg 768w\" sizes=\"auto, (max-width: 956px) 100vw, 956px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"990\" height=\"743\" data-id=\"399\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504134802_372_29.jpg\" alt=\"\" class=\"wp-image-399\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504134802_372_29.jpg 990w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504134802_372_29-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260504134802_372_29-768x576.jpg 768w\" sizes=\"auto, (max-width: 990px) 100vw, 990px\" \/><\/figure>\n<\/figure>\n<\/div>\n<p class=\"wp-block-paragraph\"><strong>\u9a8c\u6536\u7ed3\u8bba<\/strong>\uff1a_____________\u5408\u683c______________________<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e1a\u4e3b\u7b7e\u540d<\/strong>\uff1a_______________&nbsp;<strong>\u65e5\u671f<\/strong>\uff1a______2025.5_________<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee\u8d1f\u8d23\u4eba\u7b7e\u540d<\/strong>\uff1a\u4f59\u6653\u73b2&nbsp;<strong>\u65e5\u671f<\/strong>\uff1a____2025.5___________<\/p>\n<h2 id=\"tfgg04\" class=\"wp-block-heading\">\u56db\u3001\u5ba2\u6237\u53cd\u9988<\/h2>\n<p class=\"wp-block-paragraph\" id=\"tfgg041\"><strong>\u5ba2\u6237\u539f\u8bdd\u5b9e\u5f55<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53cd\u9988\u7c7b\u578b<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u539f\u8bdd<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u4e3a\u4ec0\u4e48\u9009\u62e9\u9f99\u8109<\/strong><\/td>\n<td>\u201c23\u5e74\u7684\u65f6\u5019\u5c31\u51c6\u5907\u4e3e\u5bb6\u642c\u5230\u6210\u90fd\uff0c\u7136\u540e\u5c31\u5f00\u59cb\u9010\u6e10\u8003\u5bdf\u5168\u6210\u90fd\u7684\u91c7\u6696\u7406\u5ff5\u3002\u6700\u540e\u9009\u62e9\u9f99\u8109\uff0c\u6700\u4e3b\u8981\u7684\u539f\u56e0\u662f\u4f60\u4eec\u7279\u522b\u4f18\u79c0\u8282\u80fd\u7684\u4e94\u6052\u7cfb\u7edf\u3002\u5bf9\u4e8e\u5317\u65b9\u7684\u6211\uff0c\u611f\u89c9\u8fd9\u4e2a\u7cfb\u7edf\u7279\u522b\u9002\u5408\uff0c\u6240\u4ee5\u9009\u62e9\u4e86\u9f99\u8109\u6696\u901a\u3002\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u670d\u52a1\u8bc4\u4ef7<\/strong><\/td>\n<td>\u201c\u5f88\u597d\u5f88\u597d\u3002\u4ece\u4f60\u4eec\u5f00\u59cb\u52d8\u6d4b\u73b0\u573a\u5230\u540e\u671f\u7684\u5de5\u7a0b\u5168\u8fc7\u7a0b\u7684\u7ba1\u7406\uff0c\u4ee5\u53ca\u540e\u671f\u7684\u8c03\u8bd5\u4ea4\u4ed8\uff0c\u57fa\u672c\u4e0a\u662f\u5b9e\u73b0\u4e86\u4fdd\u59c6\u7ea7\u7684\u3001\u4ece\u524d\u5230\u540e\u7684\u4e00\u4e2a\u670d\u52a1\u8fc7\u7a0b\u3002\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6548\u679c\u4e0e\u4ef7\u683c<\/strong><\/td>\n<td>\u201c\u4ef7\u683c\u5f88\u7f8e\u4e3d\uff0c\u6548\u679c\u5f88\u597d\u3002\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5165\u4f4f\u7b2c\u4e00\u611f\u89c9<\/strong><\/td>\n<td>\u201c\u521a\u88c5\u4fee\u5b8c\u5165\u4f4f\uff0c\u7b2c\u4e00\u611f\u89c9\u5c31\u662f\u6ca1\u4ec0\u4e48\u5473\u9053\uff0c\u65b0\u98ce\u7cfb\u7edf\u6bd4\u8f83\u7ed9\u529b\u3002\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u85cf\u9152\u73af\u5883<\/strong><\/td>\n<td>\u201c\u85cf\u9152\u6bd4\u8f83\u591a\uff0c\u5c4b\u91cc\u80fd\u968f\u65f6\u4fdd\u8bc1\u6052\u6e29\u3001\u6052\u6e7f\uff0c\u5f88\u653e\u5fc3\u3002\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u53cc\u7cfb\u7edf\u5bf9\u6bd4\u611f\u53d7<\/strong><\/td>\n<td>\u201c\u76ee\u524d\u5929\u6c14\u4e0d\u662f\u592a\u70ed\uff0c\u8fd8\u6bd4\u8f83\u4e0d\u51fa\u54ea\u4e2a\u7cfb\u7edf\u66f4\u80dc\u4e00\u7b79\uff0c\u611f\u89c9\u90fd\u5f88\u8212\u9002\u3002\u7b2c\u4e00\u8981\u9009\u62e9\u670d\u52a1\u5230\u4f4d\u7684\u516c\u53f8\uff0c\u80fd\u7ad9\u5230\u7528\u6237\u7684\u89d2\u5ea6\u8003\u8651\u8212\u9002\u4e0e\u8282\u80fd\uff1b\u7b2c\u4e8c\uff0c\u5728\u540c\u7b49\u6280\u672f\u4e0e\u4ea7\u54c1\u6210\u719f\u6761\u4ef6\u4e0b\uff0c\u9009\u62e9\u6027\u4ef7\u6bd4\u9ad8\u7684\u4ea7\u54c1\u4e0e\u7cfb\u7edf\u3002\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5982\u679c\u518d\u88c5\u4fee\u9009\u54ea\u4e2a<\/strong><\/td>\n<td>\u201c\u5e94\u8be5\u662f\u5929\u6c1f\u5730\u6c34\uff0c\u8fd9\u79cd\u8fd0\u884c\u65b9\u5f0f\u66f4\u7b26\u5408\u70ed\u5347\u51b7\u964d\u7684\u81ea\u7136\u89c4\u5f8b\u3002\u201d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\" id=\"tfgg042\"><strong>\u5ba2\u6237\u6ee1\u610f\u5ea6\u8bc4\u5206<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bc4\u5206\uff0810\u5206\u5236\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u6e29\u5ea6\u6548\u679c<\/td>\n<td>10\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u6e7f\u5ea6\u63a7\u5236<\/td>\n<td>10\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u6e05\u65b0\u5ea6<\/td>\n<td>10\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u9759\u97f3\u6548\u679c<\/td>\n<td>10\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u8fdc\u7a0b\u63a7\u5236<\/td>\n<td>9\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u8282\u80fd\u6548\u679c<\/td>\n<td>10\u5206<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6574\u4f53\u6ee1\u610f\u5ea6<\/strong><\/td>\n<td><strong>10\u5206<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 id=\"tfgg05\" class=\"wp-block-heading\">\u4e94\u3001\u80fd\u8017\u8ddf\u8e2a\u6863\u6848<\/h2>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u6881\u603b\uff0c\u60a8\u7684\u4e94\u6052\u7cfb\u7edf\u5df2\u7eb3\u5165\u9f99\u8109\u6696\u901a\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u3002\u6211\u4eec\u5c06\u5bf9\u7cfb\u7edf\u8fdb\u884c\u6301\u7eed\u8ddf\u8e2a\uff0c\u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a\u3002\u8fd9\u4efd\u6863\u6848\u662f\u8ddf\u8e2a\u7684\u6570\u636e\u57fa\u51c6\u3002<\/p>\n<\/blockquote>\n<h3 id=\"tfgg050\" class=\"wp-block-heading\">5.0 \u8bf4\u660e\uff1a\u8d77\u70b9\u6570\u636e\u7684\u91c7\u96c6\u539f\u5219<\/h3>\n<p class=\"wp-block-paragraph\">\u672c\u6863\u6848\u7684\u80fd\u8017\u8ddf\u8e2a\u8d77\u70b9\u4e3a\u8c03\u8bd5\u5f53\u65e5\u3002\u8d77\u70b9\u6570\u636e\u5305\u62ec\uff1a\u7535\u8868\u8bfb\u6570\u3001\u4f9b\u6c34\u6e29\u5ea6\u3001\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6\u3001\u5ba4\u5916\u6e29\u5ea6\u7b49\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6881\u603b\u9879\u76ee\u7b7e\u7ea6\u4e8e2024\u5e74\uff0c\u5f53\u65f6\u9f99\u8109\u6696\u901a\u768410\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u5c1a\u672a\u542f\u52a8\u3002\u56e0\u6b64\uff0c2025 \u5e74 5 \u6708\u8c03\u8bd5\u5f53\u65e5\u6ca1\u6709\u91c7\u96c6\u5b8c\u6574\u7684\u8d77\u70b9\u6570\u636e\u30022026 \u5e74 5 \u6708\uff0c\u516c\u53f8\u542f\u52a8 10 \u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff0c\u5df2\u6309\u8ba1\u5212\u5bf9\u672c\u6863\u6848\u505a\u56de\u6eaf\u8865\u5f55\uff1b\u5f53\u5e74\u7f3a\u7684\u8d77\u70b9\u6570\u636e\u53ea\u6309\u7535\u8d39\u8d26\u5355\u4f30\u7b97\uff0c\u4e0d\u505a\u4e8b\u540e\u8865\u586b\u3002<\/p>\n<h3 id=\"tfgg051\" class=\"wp-block-heading\">5.1 \u6570\u636e\u57fa\u51c6\uff08\u8c03\u8bd5\u5f53\u65e5\u8bb0\u5f55\uff09\uff1a\u8868\u683c\u4e3a\u793a\u4f8b\uff0c\u8be6\u7ec6\u6570\u636e\u89c1\u793a\u4f8b\u4e0b\u6587<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u57fa\u51c6\u6570\u636e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8c03\u8bd5\u65e5\u671f<\/td>\n<td>2025\u5e745\u6708<\/td>\n<\/tr>\n<tr>\n<td>\u516c\u533a\u6c34\u7cfb\u7edf\u4f9b\u6c34\u6e29\u5ea6<\/td>\n<td>___\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u79c1\u533a\u6c1f\u7cfb\u7edf\u8bbe\u5b9a\u6e29\u5ea6<\/td>\n<td>___\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u5916\u6e29\u5ea6<\/td>\n<td>___\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6<\/td>\n<td>___\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u9152\u7a96\u6e29\u5ea6\/\u6e7f\u5ea6<\/td>\n<td>___\u2103 \/ ___%<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u8868\u521d\u59cb\u8bfb\u6570<\/td>\n<td>___kWh<\/td>\n<\/tr>\n<tr>\n<td>\u516c\u533a\u4e3b\u673a\u578b\u53f7<\/td>\n<td>\u6c34\u5885\u9002VF RAS-280FEWNY1Q\/M<\/td>\n<\/tr>\n<tr>\n<td>\u79c1\u533a\u4e3b\u673a\u578b\u53f7<\/td>\n<td>\u667a\u4eab RAS-140FSPUNQ<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u603b\u9762\u79ef<\/td>\n<td>\u7ea6292.6\u33a1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-16 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" data-id=\"894\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf01-576x1024.jpg\" alt=\"\" class=\"wp-image-894\" style=\"width:602px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf01-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf01-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf01-768x1365.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf01-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf01.jpg 1080w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"1920\" data-id=\"895\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf02.jpg\" alt=\"\" class=\"wp-image-895\" style=\"width:606px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf02.jpg 1080w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf02-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf02-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf02-768x1365.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf02-864x1536.jpg 864w\" sizes=\"auto, (max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" data-id=\"896\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf03-576x1024.jpg\" alt=\"\" class=\"wp-image-896\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf03-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf03-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf03-768x1365.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf03-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf03.jpg 1080w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<\/figure>\n<\/div>\n<h3 id=\"tfgg052\" class=\"wp-block-heading\">5.2 \u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55\uff1a<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5236\u51b7\u5b63(\u6708)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u5b63(\u6708)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u603b\u7528\u7535\u91cf(kWh)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u603b\u8d39\u7528(\u5143)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6708\u5747\u8d39\u7528(\u5143)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d\u8d39\u7528(\u5143\/\u33a1\u00b7\u6708)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4e1a\u4e3b\u53cd\u9988<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u7b2c1\u5e74<\/td>\n<td>2025\u5e74<\/td>\n<td>\u2014<\/td>\n<td>\u672a\u5b8c\u6574\u8bb0\u5f55<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u65b0\u623f\u5165\u4f4f\uff0c\u6682\u672a\u5b8c\u6574\u7edf\u8ba1<\/td>\n<\/tr>\n<tr>\n<td>\u7b2c2\u5e74<\/td>\n<td>2026\u5e74<\/td>\n<td><\/td>\n<td>\u672a\u5b8c\u6574\u8bb0\u5f55<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>\u4e34\u65f6\u5c45\u4f4f<\/td>\n<\/tr>\n<tr>\n<td>\u7b2c3\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c4\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c5\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c6\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c7\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c8\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c9\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7b2c10\u5e74<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 id=\"tfgg053\" class=\"wp-block-heading\">5.3 \u667a\u80fd\u7535\u8868\uff08B\u7ec4-\u4e24\u8054\u4f9b\u4e13\u5c5e\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\u6881\u603b\u9879\u76ee\u7b7e\u7ea6\u4e8e2024\u5e74\uff0c\u5f53\u65f6\u9f99\u8109\u6696\u901a\u7684\u667a\u80fd\u7535\u8868+AI\u80fd\u6e90\u7ba1\u5bb6\u670d\u52a1\u5c1a\u672a\u63a8\u51fa\u3002\u56e0\u6b64\uff0c\u672c\u9879\u76ee\u672a\u914d\u7f6e\u667a\u80fd\u7535\u8868\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u73b0\u72b6<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u667a\u80fd\u7535\u8868\uff1a\u672a\u5b89\u88c5<\/li>\n<li>AI\u80fd\u6e90\u7ba1\u5bb6\uff1a\u672a\u63a5\u5165<\/li>\n<li>\u80fd\u8017\u6570\u636e\u91c7\u96c6\u65b9\u5f0f\uff1a\u624b\u52a8\u8bb0\u5f55\uff08\u901a\u8fc7\u7535\u8d39\u8d26\u5355\u4f30\u7b97\uff09<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u540e\u7eed\u8ba1\u5212<\/strong>\uff1a<\/p>\n<p class=\"wp-block-paragraph\">\u5982\u6881\u603b\u613f\u610f\u8865\u88c5\u667a\u80fd\u7535\u8868\uff0c\u9f99\u8109\u6696\u901a\u53ef\u514d\u8d39\u63d0\u4f9b\u8bbe\u5907\u5e76\u5b89\u6392\u5b89\u88c5\u3002\u8865\u88c5\u540e\uff0c\u672c\u9879\u76ee\u53ef\u63a5\u5165AI\u80fd\u6e90\u7ba1\u7406\u5e73\u53f0\uff0c\u4eab\u53d710\u5e74AI\u80fd\u6e90\u7ba1\u5bb6\u670d\u52a1\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8bf4\u660e<\/strong>\uff1a\u4ece2026\u5e74\u8d77\uff0c\u6240\u6709\u65b0\u7b7e\u7ea6\u7684\u4e24\u8054\u4f9b\u5ba2\u6237\uff08B\u7ec4\uff09\u5747\u6309\u300a\u6307\u4ee44\u300b\u8981\u6c42\uff0c\u514d\u8d39\u914d\u7f6e\u667a\u80fd\u7535\u8868\u5e76\u63a5\u5165AI\u80fd\u6e90\u7ba1\u7406\u5e73\u53f0\u3002<\/p>\n<h3 id=\"tfgg054\" class=\"wp-block-heading\">5.4 AI\u8bca\u65ad\u8bb0\u5f55\uff08\u9884\u7559\uff0c\u56fe\u7247\u4e3a\u793a\u4f8b\uff09<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u968f\u65f6\u67e5\u8be2\u5386\u53f2\u6570\u636e<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u4f60\u53ef\u4ee5\u968f\u65f6\u5411\u65b9\u6848\u987e\u95ee\u7d22\u53d6\u4efb\u610f\u65f6\u95f4\u6bb5\u7684\u5386\u53f2\u6570\u636e\u622a\u56fe\u3002\u6211\u4eec\u4f1a\u63d0\u4f9b\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u80fd\u8017\u66f2\u7ebf\u56fe<\/li>\n<li>AI\u8bca\u65ad\u539f\u6587<\/li>\n<li>\u540c\u6237\u578b\u5bf9\u6bd4\u53c2\u8003\uff08\u8131\u654f\uff09<\/li>\n<\/ul>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-17 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"858\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe01-1024x768.png\" alt=\"\" class=\"wp-image-858\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe01-1024x768.png 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe01-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe01-768x576.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe01.png 1132w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"857\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe02-1024x768.png\" alt=\"\" class=\"wp-image-857\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe02-1024x768.png 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe02-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe02-768x576.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u80fd\u6e90\u7ba1\u7406\u7cfb\u7edf\u56fe02.png 1213w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n<\/div>\n<h2 id=\"tfgg06\" class=\"wp-block-heading\">\u516d\u3001\u5ba2\u6237\u670d\u52a1\u8bb0\u5f55<\/h2>\n<p class=\"wp-block-paragraph\" id=\"tfgg061\"><strong>6.1 \u670d\u52a1\u8bb0\u5f55\u8868<\/strong><\/p>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u65e5\u671f<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u7c7b\u578b<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u5185\u5bb9<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u4eba\u5458<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u786e\u8ba4<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2025\u5e7411\u670826\u65e5<\/td>\n<td>\u91c7\u6696\u53ca\u51c0\u5316\u6548\u679c\u56de\u8bbf<\/td>\n<td>\u4e86\u89e3\u5730\u6696\u4f7f\u7528\u60c5\u51b5\u3002\u5f53\u65f6\u6881\u603b\u56de\u5bb6\uff0c\u53d1\u73b0\u5929\u5e9c\u516c\u9986\u56db\u5468\u90bb\u5c45\u90fd\u5728\u88c5\u4fee\u7684\u60c5\u51b5\u4e0b\uff0c\u7279\u522b\u7070\u5927\u4e5f\u7279\u522b\u5435\u3002\u8ba9\u6881\u603b\u6253\u5f00\u65b0\u98ce\u548c\u5185\u673a\u51c0\u5316\u529f\u80fd\uff0c\u8ddf\u8e2a\u65e5\u7acbPE\u751f\u6001\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u6548\u679c<\/td>\n<td>\u7f2a\u5f02<\/td>\n<td>\u5728\u5ba4\u5185\u4e8c\u6c27\u5316\u78b3\u6d53\u5ea6\u4e0d\u8d85\u6807\u7684\u60c5\u51b5\u4e0b\uff0c\u5173\u95ed\u65b0\u98ce\u529f\u80fd\uff0c\u5f00\u542f\u5ba4\u5185\u5faa\u73af\u51c0\u5316\u6a21\u5f0f\uff0c\u6548\u679c\u7acb\u7aff\u89c1\u5f71<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-18 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" data-id=\"898\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf05-576x1024.jpg\" alt=\"\" class=\"wp-image-898\" style=\"width:602px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf05-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf05-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf05-768x1365.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf05-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf05.jpg 1080w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1290\" height=\"2293\" data-id=\"902\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07.jpg\" alt=\"\" class=\"wp-image-902\" style=\"width:606px;height:auto\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07.jpg 1290w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07-768x1365.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf07-1152x2048.jpg 1152w\" sizes=\"auto, (max-width: 1290px) 100vw, 1290px\" \/><\/figure>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" data-id=\"899\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06-576x1024.png\" alt=\"\u5929\u5e9c\u516c\u9986\u6881\u603b\u51c0\u5316\u6548\u679c\u56de\u8bbf3\" class=\"wp-image-899\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06-576x1024.png 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06-169x300.png 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06-768x1365.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06-864x1536.png 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06-1152x2048.png 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u5929\u5e9c\u516c\u9986\u6881\u603b\u56de\u8bbf06.png 1290w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<\/figure>\n<\/div>\n<p class=\"wp-block-paragraph\" id=\"tfgg062\"><strong>6.2 \u4f18\u5316\u5efa\u8bae\u8ddf\u8e2a\u8868<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u65e5\u671f<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u5185\u5bb9<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6267\u884c\u60c5\u51b5<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6548\u679c\u9a8c\u8bc1<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8ddf\u8e2a\u72b6\u6001<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2025.11.26<\/td>\n<td>\u5173\u95ed\u65b0\u98ce\u3001\u5f00\u542f\u5185\u673a\u5faa\u73af\u51c0\u5316\uff08\u56db\u5468\u88c5\u4fee\u7070\u5c18\u5927\uff09<\/td>\n<td>\u5df2\u6267\u884c<\/td>\n<td>\u6548\u679c\u7acb\u7aff\u89c1\u5f71<\/td>\n<td>\u2705 \u5df2\u95ed\u73af<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<\/div>\n<h2 id=\"tfgg07\" class=\"wp-block-heading\">\u4e03\u3001\u9644\u4ef6\u6e05\u5355<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9644\u4ef6\u540d\u79f0<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5f62\u5f0f<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5b58\u6863\u4f4d\u7f6e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u524d\u4e66<\/td>\n<td>PDF<\/td>\n<td>IMA\u77e5\u8bc6\u5e93<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u7ba1\u8def\u8d70\u5411\u8bbe\u8ba1\u56fe\uff08\u516c\u533a\u6c34\u7cfb\u7edf+\u79c1\u533a\u6c1f\u7cfb\u7edf\uff09<\/td>\n<td>CAD\/PDF<\/td>\n<td>IMA\u77e5\u8bc6\u5e93<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u7cbe\u5de5\u516d\u6b65\u6cd5+2 \u65bd\u5de5\u7167\u7247\u96c6<\/td>\n<td>\u7167\u7247\/VR\u5168\u666f<\/td>\n<td>IMA\u77e5\u8bc6\u5e93<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd\u5361<\/td>\n<td>\u7eb8\u8d28<\/td>\n<td>\u5ba2\u6237\u7559\u5b58<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/td>\n<td>\u7eb8\u8d28+\u626b\u63cf\u4ef6<\/td>\n<td>\u53cc\u5b58\u6863<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u4f7f\u7528\u624b\u518c<\/td>\n<td>\u7eb8\u8d28+\u7535\u5b50\u7248<\/td>\n<td>\u5ba2\u6237\u7559\u5b58<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u6881\u603b\u89c6\u9891\u91c7\u8bbf\uff08\u5c0f\u7ea2\u4e66\u5b98\u65b9\u8d26\u53f7\uff09<\/td>\n<td>\u89c6\u9891<\/td>\n<td>\u9f99\u8109\u6696\u901a\u5c0f\u7ea2\u4e66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6863\u6848\u4e66\u7ed3\u675f\u3002<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u00b7\u4f59\u6653\u73b2<br \/>2026\u5e745\u6708\uff08\u6863\u6848\u4e66\u56de\u6eaf\u8865\u5f55\uff09<\/p>\n<h2 id=\"tfgg08\" class=\"wp-block-heading\">\u516b\u3001\u9f99\u8109\u6696\u901a\u00b7\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u524d\u4e66<\/h2>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u6881\u603b<br \/><strong>\u9879\u76ee<\/strong>\uff1a\u5929\u5e9c\u516c\u9986\u00b7\u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf<br \/><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a[\u65b9\u6848DS]<br \/><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670812\u65e5\uff08\u8865\u5f55\uff0c\u539f\u5408\u540c\u7b7e\u7f72\u4e8e2024\u5e74\uff09<br \/><strong>\u6587\u6863\u7f16\u53f7<\/strong>\uff1aLY-2024-LIANG-001<\/p>\n<h3 class=\"wp-block-heading\">8.1\u3001\u5ba2\u6237\u9700\u6c42\u7406\u89e3<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u8bf4\u7684<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7406\u89e3\u7684<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u201c\u6210\u90fd\u51ac\u5929\u6e7f\u51b7\u523a\u9aa8\uff0c\u53d7\u4e0d\u4e86\u201d<\/td>\n<td>\u5317\u65b9\u4eba\u5bf9\u6210\u90fd\u51ac\u5b63\u9ad8\u6e7f\u4f4e\u6e29\u7684\u4f53\u611f\u4e0d\u9002\u5e94\u2014\u2014\u6e29\u5ea60-8\u2103\u4f46\u6e7f\u5ea680%+\uff0c\u4f53\u611f\u6e29\u5ea6\u6bd4\u5b9e\u9645\u4f4e3-5\u2103\u3002\u666e\u901a\u7a7a\u8c03\u70ed\u98ce\u5439\u4e0d\u5230\u811a\uff0c\u5730\u6696\u662f\u521a\u9700<\/td>\n<\/tr>\n<tr>\n<td>\u201c\u6536\u85cf\u4e86\u5f88\u591a\u540d\u9152\uff0c\u9152\u7a96\u4e0d\u80fd\u51fa\u95ee\u9898\u201d<\/td>\n<td>\u9152\u7a96\u9700\u8981\u5168\u5e74\u6052\u6e29\u6052\u6e7f\u2014\u2014\u6e29\u5ea618-22\u2103\uff0c\u6e7f\u5ea650%\u00b15%\u3002\u666e\u901a\u7a7a\u8c03\u548c\u9664\u6e7f\u673a\u505a\u4e0d\u5230\u7cbe\u51c6\u63a7\u5236\uff0c\u5fc5\u987b\u72ec\u7acb\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u201c\u5168\u56fd\u5404\u5730\u670b\u53cb\u591a\uff0c\u7ecf\u5e38\u5728\u5bb6\u805a\u4f1a\u201d<\/td>\n<td>1-3\u697c\u516c\u533a\u957f\u65f6\u95f4\u63a5\u5f8510-20\u4eba\uff0c\u5bf9\u7a7a\u6c14\u8d28\u91cf\u3001\u9759\u97f3\u3001\u65e0\u98ce\u611f\u8981\u6c42\u6781\u9ad8\u3002\u5ba2\u4eba\u611f\u53d7\u4e0d\u5230\u8bbe\u5907\u5b58\u5728\uff0c\u624d\u662f\u6700\u597d\u7684\u8212\u9002<\/td>\n<\/tr>\n<tr>\n<td>\u201c\u4e0d\u5e38\u4f4f\u5728\u6210\u90fd\uff0c\u7ecf\u5e38\u56de\u5317\u65b9\u201d<\/td>\n<td>\u7cfb\u7edf\u9700\u8981\u8fdc\u7a0b\u53ef\u63a7\u3001\u5206\u533a\u8fd0\u884c\u2014\u2014\u4e0d\u5e38\u4f4f\u65f6\u53ea\u5f00\u57fa\u7840\u4fdd\u969c\uff0c\u805a\u4f1a\u65f6\u5168\u5f00\u3002\u53cc\u7cfb\u7edf\u5197\u4f59\uff1a\u4e00\u5957\u51fa\u95ee\u9898\uff0c\u53e6\u4e00\u5957\u4ecd\u53ef\u4fdd\u969c\u57fa\u7840\u751f\u6d3b<\/td>\n<\/tr>\n<tr>\n<td>\u201c\u5e0c\u671b\u4e00\u6b65\u5230\u4f4d\uff0c\u672a\u676520\u5e74\u4e0d\u6298\u817e\u201d<\/td>\n<td>\u4e0d\u662f\u521d\u6295\u8d44\u6700\u4f4e\uff0c\u662f\u957f\u671f\u7a33\u5b9a\u3001\u4e0d\u843d\u4f0d\u3002\u7cfb\u7edf\u9700\u8981\u53ef\u5347\u7ea7\uff08OTA\uff09\uff0c\u552e\u540e\u9700\u8981\u957f\u671f\u4fdd\u969c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">8.2\u3001\u8bbe\u8ba1\u7406\u5ff5<\/h3>\n<h3 class=\"wp-block-heading\">8.2.1 \u6838\u5fc3\u539f\u5219\uff1a\u6c34\u6c1f\u590d\u5408\uff0c\u5206\u5c42\u5b9a\u5236<\/h3>\n<p class=\"wp-block-paragraph\">\u6881\u603b\u5bb6\u4e0d\u662f\u201c\u4e00\u5957\u7cfb\u7edf\u7ba1\u5168\u5c4b\u201d\u7684\u6807\u51c6\u7b54\u6848\u30021-3\u697c\u516c\u533a\u548c4\u697c\u79c1\u533a\u7684\u4f7f\u7528\u573a\u666f\u5b8c\u5168\u4e0d\u540c\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">1-3\u697c\u516c\u533a<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">4\u697c\u79c1\u533a<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u7ed3\u8bba<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u4f7f\u7528\u9891\u7387<\/td>\n<td>\u63a5\u5f85\u65f6\u5168\u5f00\uff0c\u5e73\u65f6\u65e0\u4eba<\/td>\n<td>\u5076\u5c14\u56de\u6765\u4f4f<\/td>\n<td>\u516c\u533a\u9700\u8981\u957f\u65f6\u95f4\u8fd0\u884c\u8212\u9002\u5ea6\u9ad8\uff0c\u79c1\u533a\u9700\u8981\u5feb\u901f\u54cd\u5e94<\/td>\n<\/tr>\n<tr>\n<td>\u505c\u7559\u65f6\u95f4<\/td>\n<td>\u805a\u4f1a\u6301\u7eed4-8\u5c0f\u65f6<\/td>\n<td>\u7761\u77208\u5c0f\u65f6<\/td>\n<td>\u516c\u533a\u7528\u6c34\u7cfb\u7edf\uff08\u51fa\u98ce\u67d4\u548c\u3001\u4e0d\u5e72\u71e5\uff09\uff0c\u79c1\u533a\u7528\u6c1f\u7cfb\u7edf\uff08\u5236\u51b7\u5feb\u3001\u8282\u80fd\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4eba\u6570\u8d1f\u8377<\/td>\n<td>10-20\u4eba<\/td>\n<td>2\u4eba<\/td>\n<td>\u516c\u533a\u9700\u8981\u5927\u51b7\u91cf\u3001\u9ad8\u65b0\u98ce\u91cf\uff0c\u79c1\u533a\u4f4e\u8d1f\u8377\u5373\u53ef<\/td>\n<\/tr>\n<tr>\n<td>\u5907\u7528\u9700\u6c42<\/td>\n<td>\u4e3b\u673a\u6545\u969c\u65f6\u5168\u5c4b\u762b\u75ea<\/td>\n<td>\u4e0d\u5f71\u54cd\u516c\u533a<\/td>\n<td>\u53cc\u7cfb\u7edf\u4e92\u4e3a\u5907\u4efd\uff0c\u4e00\u5957\u6545\u969c\u53e6\u4e00\u5957\u4ecd\u53ef\u4fdd\u969c\u57fa\u7840\u751f\u6d3b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a\u4e00\u5957\u5927\u7cfb\u7edf\u5168\u5c4b\u7edf\u4e00\u8fd0\u884c\uff0c\u4f1a\u5bfc\u81f4\u516c\u533a\u5f00\u7684\u65f6\u5019\u79c1\u533a\u88ab\u8feb\u5f00\u673a\uff08\u6d6a\u8d39\u80fd\u6e90\uff09\uff0c\u6216\u8005\u79c1\u533a\u5f00\u7684\u65f6\u5019\u516c\u533a\u5927\u4e3b\u673a\u4f4e\u8d1f\u8377\u8fd0\u884c\uff08\u9891\u7e41\u542f\u505c\uff09\u3002\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff0c\u6309\u9700\u8fd0\u884c\uff0c\u7efc\u5408\u8282\u80fd30%\u4ee5\u4e0a\u3002<\/p>\n<h3 class=\"wp-block-heading\">8.2.2 \u8bbe\u8ba1\u903b\u8f91\uff1a\u4ece\u5ba2\u6237\u62c5\u5fc3\u7684\u201c\u6e7f\u51b7\u201d\u51fa\u53d1<\/h3>\n<p class=\"wp-block-paragraph\">\u6881\u603b\u5728\u6210\u90fd\u8fc7\u51ac\u7684\u4f53\u9a8c\u662f\u201c\u6e7f\u51b7\u523a\u9aa8\u201d\u2014\u2014\u8fd9\u4e0d\u662f\u6e29\u5ea6\u95ee\u9898\uff0c\u662f<strong>\u6e7f\u5ea6+\u4f4e\u6e29<\/strong>\u7684\u53e0\u52a0\u6548\u5e94\u3002\u89e3\u51b3\u8def\u5f84\uff1a<\/p>\n<p class=\"wp-block-paragraph\">text<\/p>\n<pre class=\"wp-block-preformatted\">\u6210\u90fd\u51ac\u5b63\u6e7f\u51b7\uff080-8\u2103\uff0c\u6e7f\u5ea680%+\uff09\n        \u2193\n\u4f53\u611f\u6e29\u5ea6\u6bd4\u5b9e\u9645\u4f4e3-5\u2103\n        \u2193\n\u89e3\u51b3\u65b9\u6848\u4e0d\u662f\u201c\u52a0\u5927\u7a7a\u8c03\u529f\u7387\u201d\n        \u2193\n\u800c\u662f\u201c\u5730\u6696\u89e3\u51b3\u811a\u51b7 + \u6c34\u7cfb\u7edf\u51fa\u98ce\u67d4\u548c\u89e3\u51b3\u4f53\u611f + \u72ec\u7acb\u9664\u6e7f\u89e3\u51b3\u6e7f\u5ea6\u201d\n        \u2193\n\u4e94\u6052\u7cfb\u7edf = \u6052\u6e29 + \u6052\u6e7f + \u6052\u6c27 + \u6052\u6d01 + \u6052\u9759<\/pre>\n<p class=\"wp-block-paragraph\">\u8fd9\u5957\u903b\u8f91\u51b3\u5b9a\u4e86\uff1a\u6881\u603b\u5bb6\u4e0d\u662f\u4e70\u4e00\u5957\u8d35\u7684\u7a7a\u8c03\uff0c\u800c\u662f\u914d\u4e00\u5957\u80fd\u5728\u6210\u90fd\u6c14\u5019\u4e0b\u771f\u6b63\u8212\u9002\u7684\u7a7a\u6c14\u7ba1\u7406\u7cfb\u7edf\u3002<\/p>\n<h3 class=\"wp-block-heading\">8.3\u3001\u7cfb\u7edf\u8bbe\u8ba1\u8bf4\u660e<\/h3>\n<h4 class=\"wp-block-heading\">8.3.1 \u516c\u533a\uff081-3\u697c\uff09\uff1a\u6c34\u7cfb\u7edf\u4e94\u6052\u2014\u2014\u5929\u6c34\u5730\u6c34<\/h4>\n<p class=\"wp-block-paragraph\"><strong>\u4e3a\u4ec0\u4e48\u9009\u5929\u6c34\u5730\u6c34\uff1f<\/strong><\/p>\n<p class=\"wp-block-paragraph\">1-3\u697c\u516c\u533a\u662f\u957f\u65f6\u95f4\u63a5\u5f85\u573a\u6240\u3002\u805a\u4f1a\u65f610-20\u4eba\u5728\u5ba2\u5385\u3001\u9910\u5385\u3001\u5a31\u4e50\u533a\u6d3b\u52a8\uff0c\u505c\u7559\u65f6\u95f44-8\u5c0f\u65f6\u3002\u6c34\u7cfb\u7edf\u51fa\u98ce\u6e29\u5ea615-20\u2103\uff08\u6c1f\u7cfb\u7edf\u51fa\u98ce7-12\u2103\uff09\uff0c\u51c9\u800c\u4e0d\u5bd2\u3001\u65e0\u5439\u98ce\u611f\uff0c\u5ba2\u4eba\u957f\u65f6\u95f4\u5750\u7740\u804a\u5929\u3001\u54c1\u9152\u3001\u7528\u9910\uff0c\u4e0d\u4f1a\u89c9\u5f97\u51b7\u98ce\u76f4\u5439\u6216\u76ae\u80a4\u5e72\u71e5\u3002\u8fd9\u662f\u6c1f\u7cfb\u7edf\u505a\u4e0d\u5230\u7684\u4f53\u611f\u5dee\u5f02\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6b64\u5916\uff0c\u6c34\u7cfb\u7edf\u8fde\u63a5\u7387\u4e0d\u53d7\u9650\uff08\u53ef\u8d85200%\uff09\uff0c\u516c\u533a\u5185\u673a\u591a\u8fbe10\u53f0\uff0c\u5355\u53f0\u5927\u5916\u673a\u6216\u6c1f\u7cfb\u7edf\u591a\u53f0\u5e76\u8054\u90fd\u65e0\u6cd5\u5b9e\u73b0\u8fd9\u79cd\u7075\u6d3b\u6027\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u8bbe\u5907\u914d\u7f6e<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\/\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd\u7279\u6027<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u4e3b\u673a<\/td>\n<td>\u65e5\u7acb\u6c34\u5885\u9002VF<\/td>\n<td>RAS-280FEWNY1Q\/M<\/td>\n<td>1\u53f0<\/td>\n<td>\u5168\u53d8\u9891\uff08\u538b\u7f29\u673a+\u6c34\u6cf5+\u98ce\u673a\uff09\/\u8865\u6c14\u589e\u7113\u6da1\u65cb\/-30\u2103\u5236\u70ed\/COP\u22653.0<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a<\/td>\n<td>\u96f6\u8d8aDC\u98ce\u673a\u76d8\u7ba1<\/td>\n<td>\u5e26PE\u51c0\u5316\u6a21\u5757<\/td>\n<td>10\u53f0<\/td>\n<td>\u76f4\u6d41\u65e0\u5237\/\u6700\u4f4e19.5dB\/\u5168\u5305\u5f0f\u7ed3\u6784\uff08\u675c\u7edd\u7ed3\u9732\u6ce1\u9876\uff09\/PE\u51c0\u5316<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce<\/td>\n<td>\u5929\u51c0\u9664\u6e7f\u65b0\u98ce<\/td>\n<td>350\u98ce\u91cf<\/td>\n<td>2\u53f0\uff081-2\u697c\uff09<\/td>\n<td>\u72ec\u7acb\u9664\u6e7f+\u5168\u70ed\u56de\u6536+\u4e94\u7ef4\u76d1\u6d4b\uff08\u6e29\/\u6e7f\/PM2.5\/CO\u2082\/TVOC\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce<\/td>\n<td>\u5929\u51c0\u9664\u6e7f\u65b0\u98ce<\/td>\n<td>250\u98ce\u91cf<\/td>\n<td>1\u53f0\uff083\u697c\uff09<\/td>\n<td>\u540c\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236<\/td>\n<td>\u667a\u5885\u5168\u611f2.0<\/td>\n<td>\u2014<\/td>\n<td>1\u5957<\/td>\n<td>\u522b\u5885\u5b9a\u5236\/\u4f1a\u5ba2\/\u805a\u9910\/\u9152\u7a96\u6a21\u5f0f\u4e00\u952e\u5207\u6362\/AI\u8054\u52a8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">8.3.2 \u79c1\u533a\uff084\u697c\uff09\uff1a\u6c1f\u7cfb\u7edf\u4e94\u6052\u2014\u2014\u5929\u6c1f\u5730\u6c34<\/h4>\n<p class=\"wp-block-paragraph\"><strong>\u4e3a\u4ec0\u4e48\u9009\u5929\u6c1f\u5730\u6c34\uff1f<\/strong><\/p>\n<p class=\"wp-block-paragraph\">4\u697c\u662f\u6881\u603b\u548c\u592b\u4eba\u7684\u4e3b\u5367\u5957\u95f4\uff0c\u5076\u5c14\u56de\u6765\u4f4f\u3002\u4f7f\u7528\u7279\u70b9\u662f\u201c\u4e0d\u5e38\u5f00\u3001\u4e00\u5f00\u5c31\u8981\u5feb\u901f\u51b7\u4e0b\u6765\/\u70ed\u8d77\u6765\u201d\u3002\u6c1f\u7cfb\u7edf\u5236\u51b7\u5feb\uff08\u6c1f\u5229\u6602\u76f4\u51b7\uff0c\u51fa\u98ce7-12\u2103\uff09\uff0c\u6bd4\u6c34\u7cfb\u7edf\u54cd\u5e94\u901f\u5ea6\u66f4\u5feb\uff0c\u66f4\u9002\u5408\u95f4\u6b47\u4f7f\u7528\u3002\u6b64\u5916\uff0c4\u697c\u9762\u79ef\u7ea650\u33a1\uff0c\u53ea\u9700\u89813\u53f0\u5185\u673a\uff0c\u7528\u4e00\u53f0\u5c0f\u5916\u673a\u72ec\u7acb\u8fd0\u884c\u5373\u53ef\u2014\u2014\u5982\u679c\u5e76\u5165\u516c\u533a\u5927\u7cfb\u7edf\uff0c\u5f00\u4e00\u4e2a\u5367\u5ba4\u4e5f\u8981\u542f\u52a8\u5927\u4e3b\u673a\uff0c\u80fd\u8017\u6d6a\u8d39\u4e25\u91cd\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u667a\u4eab\u7cfb\u5217\u4e3b\u673a\u5185\u7f6e\u6c34\u6a21\u5757\uff0c\u65e0\u9700\u989d\u5916\u5b89\u88c5\u6c34\u6a21\u5757\u8bbe\u5907\uff0c4\u697c\u7a7a\u95f4\u7d27\u51d1\uff0c\u5b89\u88c5\u66f4\u7b80\u6d01\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u8bbe\u5907\u914d\u7f6e<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\/\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd\u7279\u6027<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u4e3b\u673a<\/td>\n<td>\u65e5\u7acb\u667a\u4eab<\/td>\n<td>RAS-140FSPUNQ<\/td>\n<td>1\u53f0<\/td>\n<td>\u5929\u6c1f\u5730\u6c34\/\u5185\u7f6e\u6c34\u6a21\u5757\/\u5168\u76f4\u6d41\u53d8\u9891\/APF 5.0+<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a<\/td>\n<td>\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td>\n<td>\u5e26\u81ea\u6e05\u6d01+PE\u51c0\u5316<\/td>\n<td>3\u53f0<\/td>\n<td>\u81ea\u6e05\u6d01+56\u2103\u9ad8\u6e29\u6740\u83cc\/\u6700\u4f4e17dB\/PE\u51c0\u5316PM2.5\u53bb\u9664\u738799%<\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce<\/td>\n<td>\u5929\u51c0\u9664\u6e7f\u65b0\u98ce<\/td>\n<td>250\u98ce\u91cf<\/td>\n<td>1\u53f0<\/td>\n<td>\u72ec\u7acb\u9664\u6e7f+\u5168\u70ed\u56de\u6536+\u4e94\u7ef4\u76d1\u6d4b<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236<\/td>\n<td>\u5168\u5c4b\u5168\u611f2.0<\/td>\n<td>\u2014<\/td>\n<td>1\u5957<\/td>\n<td>AI\u81ea\u5b66\u4e60\/\u8fdc\u7a0b\u63a7\u5236\/OTA\u5347\u7ea7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">8.3.3 \u9152\u7a96\uff1a\u72ec\u7acb\u7cbe\u51c6\u63a7\u6e7f<\/h4>\n<p class=\"wp-block-paragraph\">\u6881\u603b\u6536\u85cf\u540d\u9152\uff0c\u9152\u7a96\u9700\u8981\u5168\u5e74\u6052\u6e29\u6052\u6e7f\uff1a\u6e29\u5ea618-22\u2103\uff0c\u6e7f\u5ea650%\u00b15%\u3002\u666e\u901a\u7a7a\u8c03\u9664\u6e7f\u4f34\u968f\u964d\u6e29\uff0c\u65e0\u6cd5\u505a\u5230\u201c\u53ea\u9664\u6e7f\u4e0d\u964d\u6e29\u201d\u3002\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u72ec\u7acb\u8fd0\u884c\uff0c\u7cbe\u51c6\u63a7\u5236\u6e7f\u5ea6\u2014\u2014\u9664\u6e7f\u540e\u51fa\u98ce\u6e29\u5ea618-26\u2103\uff0c\u4e0d\u62c9\u4f4e\u6e29\uff0c\u4e0d\u5f71\u54cd\u9152\u7a96\u6e29\u5ea6\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u9152\u7a96\u4e13\u7528\u914d\u7f6e\uff1a\u72ec\u7acb\u5929\u51c0\u9664\u6e7f\u65b0\u98ce24\u5c0f\u65f6\u8fd0\u884c\uff0c\u7ed3\u5408\u6c34\u7cfb\u7edf\u98ce\u76d8\u6052\u6e29\u63a7\u5236\u3002\u6e7f\u5ea6\u8d85\u6807\u65f6\u9664\u6e7f\u65b0\u98ce\u81ea\u52a8\u52a0\u5927\u9664\u6e7f\u91cf\uff0c\u6e7f\u5ea6\u8fbe\u6807\u540e\u81ea\u52a8\u5207\u6362\u4f4e\u98ce\u91cf\u7ef4\u6301\u3002<\/p>\n<h4 class=\"wp-block-heading\">8.3.4 \u8bbe\u8ba1\u53c2\u6570\u4e0e\u6280\u672f\u6807\u51c6<\/h4>\n<p class=\"wp-block-paragraph\"><strong>\u4e94\u6052\u8bbe\u8ba1\u6307\u6807<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u76ee\u6807<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4f9d\u636e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u6052\u6e29<\/td>\n<td>\u516c\u533a22-26\u2103\/\u79c1\u533a20-24\u2103\/\u9152\u7a9618-22\u2103\uff08\u6ce2\u52a8\u00b11\u2103\uff09<\/td>\n<td>GB 50736-2012\/T-CAS 1009-2025<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e7f<\/td>\n<td>40%-60%\/\u9152\u7a9650%\u00b15%<\/td>\n<td>T-CAS 1009-2025<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6c27<\/td>\n<td>CO\u2082\u2264800ppm<\/td>\n<td>GB\/T 18883<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6d01<\/td>\n<td>PM2.5\u226425\u03bcg\/m\u00b3<\/td>\n<td>T-CECS 1800<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u9759<\/td>\n<td>\u516c\u533a\u226435dB\/\u5367\u5ba4\u226430dB<\/td>\n<td>GB 50118<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7cfb\u7edf\u8bbe\u8ba1\u53c2\u6570<\/strong>\uff1a\u516c\u533a\u7a7a\u8c03\u9762\u79ef\u7ea6242.6\u33a1\uff0c\u5730\u6696\u9762\u79ef\u7ea6217.9\u33a1\uff0c\u51b7\u8d1f\u8377\u6309GB 50736\u522b\u5885\u6807\u51c6150-220W\/\u33a1\u8ba1\u7b97\uff0c\u8d85\u914d\u7387\u63a7\u5236\u5728110%-130%\u5408\u7406\u533a\u95f4\u3002\u79c1\u533a\u7a7a\u8c03\u9762\u79ef\u7ea650\u33a1\uff0c\u6309\u9ad8\u5c42\u4f4f\u5b85\u6807\u51c680-120W\/\u33a1\u8ba1\u7b97\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6c34\u7cfb\u7edf\u7ba1\u8def\u8bbe\u8ba1<\/strong>\uff1a\u4e3b\u7ba1\u91c7\u7528PPR S3.2\uff08\u4e24\u8054\u4f9b\u4e3b\u7ba1\u9053\u5f3a\u5236\u58c1\u539a\u7b49\u7ea7\uff09\uff0c\u7ba1\u5f84\u6309\u6c34\u529b\u8ba1\u7b97\u9009\u578b\u3002\u672b\u7aef\u91c7\u7528\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\uff0c\u786e\u4fdd\u5404\u56de\u8def\u6c34\u529b\u5e73\u8861\u3002\u4e00\u6b21\u7cfb\u7edf\u4f18\u5148\u2014\u2014\u6c34\u5885\u9002VF\u5168\u53d8\u9891\u6c34\u6cf5\u81ea\u9002\u5e94\u53d8\u6d41\u91cf\uff0c\u7cfb\u7edf\u6c34\u91cf\u6ee1\u8db3\u5f00\u5229\u6807\u51c6\uff08\u5236\u51b7\u91cf\u00d73.25L\/kW\uff09\uff0c\u65e0\u9700\u7f13\u51b2\u6c34\u7bb1\u3002<\/p>\n<h3 class=\"wp-block-heading\">8.4\u3001\u65bd\u5de5\u670d\u52a1\u627f\u8bfa<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8bbe\u8ba1\u6807\u51c6<\/td>\n<td>\u6309GB 50736-2012\u3001JGJ 142-2012\u8bbe\u8ba1\uff1b\u4e94\u6052\u6307\u6807\u5bf9\u7167T\/CAS 1009-2025\uff082025\u5e742\u6708\u53d1\u5e03\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u65bd\u5de5\u6807\u51c6<\/td>\n<td>\u65e5\u7acb\u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6 + \u4e09\u9053\u5bc6\u5c01\u5de5\u827a + \u5168\u7a0b\u5145\u6c2e\u4fdd\u62a4\u710a<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u6750\u8d28\u4fdd<\/td>\n<td>\u4f1f\u661f\u5382\u5bb650\u5e74 + \u4e2d\u56fd\u4eba\u4fdd\u627f\u4fdd<\/td>\n<\/tr>\n<tr>\n<td>\u5de5\u7a0b\u8d28\u4fdd<\/td>\n<td>5\u5e74\u8d77<\/td>\n<\/tr>\n<tr>\n<td>\u4e09\u65b9\u8054\u4fdd<\/td>\n<td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td>\n<\/tr>\n<tr>\n<td>\u552e\u540e\u670d\u52a1<\/td>\n<td>\u4f1a\u5458\u7ec8\u8eab\u670d\u52a1\uff08\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192+\u4f18\u5148\u54cd\u5e94+\u8fdc\u7a0b\u8bca\u65ad\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">8.5\u3001\u8bbe\u8ba1\u4f9d\u636e<\/h3>\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u8bbe\u8ba1\u4f9d\u636e\u4ee5\u4e0b\u516c\u5f00\u53ef\u67e5\u7684\u56fd\u5bb6\u6807\u51c6\u4e0e\u884c\u4e1a\u89c4\u8303\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u672c\u65b9\u6848\u5f15\u7528\u5904<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GB 50736-2012<\/td>\n<td>\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td>\n<td>\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97<\/td>\n<\/tr>\n<tr>\n<td>JGJ 142-2012<\/td>\n<td>\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td>\n<td>\u5730\u6696\u7cfb\u7edf\u8bbe\u8ba1<\/td>\n<\/tr>\n<tr>\n<td>T\/CAS 1009-2025<\/td>\n<td>\u667a\u6167\u4eba\u5c45\u73af\u5883\u5ba4\u5185\u4e94\u6052\u7cfb\u7edf\u5de5\u7a0b\u6280\u672f\u89c4\u8303<\/td>\n<td>\u4e94\u6052\u6307\u6807\u8bbe\u5b9a<\/td>\n<\/tr>\n<tr>\n<td>GB\/T 18883<\/td>\n<td>\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u6807\u51c6<\/td>\n<td>CO\u2082\/PM2.5\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>GB 50118<\/td>\n<td>\u6c11\u7528\u5efa\u7b51\u9694\u58f0\u8bbe\u8ba1\u89c4\u8303<\/td>\n<td>\u566a\u97f3\u6807\u51c6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6807\u51c6\u5e74\u4efd\u8bf4\u660e<\/strong>\uff1a\u4e0a\u8868\u91cc\u7684 T\/CAS 1009-2025\u300a\u667a\u6167\u4eba\u5c45\u73af\u5883\u5ba4\u5185\u4e94\u6052\u7cfb\u7edf\u5de5\u7a0b\u6280\u672f\u89c4\u8303\u300b\u662f\u4e2d\u56fd\u6807\u51c6\u5316\u534f\u4f1a\u7684\u56e2\u4f53\u6807\u51c6\uff0c2025 \u5e74 2 \u6708 8 \u65e5\u53d1\u5e03\u5e76\u5b9e\u65bd\u3002\u672c\u9879\u76ee 2024 \u5e74\u5b8c\u6210\u8bbe\u8ba1\uff0c\u5f53\u65f6\u8fd9\u4efd\u6807\u51c6\u8fd8\u6ca1\u6709\u53d1\u5e03\uff0c\u6240\u4ee5\u5b83\u4e0d\u662f\u5f53\u5e74\u8bbe\u8ba1\u7684\u4f9d\u636e\u30022026 \u5e74 5 \u6708\u56de\u6eaf\u8865\u5f55\u8fd9\u4efd\u6863\u6848\u4e66\u65f6\uff0c\u6309\u5f53\u65f6\u7684\u73b0\u884c\u6807\u51c6\u505a\u4e86\u4e94\u6052\u6307\u6807\u5bf9\u7167\uff0c\u624d\u628a\u5b83\u5217\u8fdb\u8fd9\u5f20\u8868\u30022024 \u5e74\u8bbe\u8ba1\u7528\u7684\u662f GB 50736-2012\u3001JGJ 142-2012 \u7b49\u5f53\u65f6\u5df2\u7ecf\u65bd\u884c\u7684\u6807\u51c6\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7406\u8bba\u6846\u67b6\u4f9d\u636e<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>[<a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/home-environment.html\">\u9f99\u8109\u6696\u901a\u00b7\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66<\/a>]\u2014\u2014\u4e94\u5c42\u9700\u6c42\u7406\u8bba\u00b7\u516d\u7ef4\u6807\u51c6\u00b7\u56db\u8981\u7d20\u8bbe\u8ba1\u6cd5\u00b7\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u5206\u6790<\/li>\n<li>[<a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/fluorine.html\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u53ca\u4e24\u8054\u4f9b\u00b7\u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a>]\u2014\u2014\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u8bbe\u8ba1<\/li>\n<li>[<a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/water.html\">\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u00b7\u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a>]\u2014\u2014\u6c34\u5885\u9002VF\u7cfb\u7edf\u8bbe\u8ba1<\/li>\n<li>[<a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/five-constant.html\">\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7\u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a>]\u2014\u2014\u4e94\u6052\u5168\u7ef4\u7ba1\u7406<\/li>\n<\/ul>\n<div style=\"margin:26px 0;padding:16px 18px;background:#f6f8fa;border-left:4px solid #1a2b3c;border-radius:8px;\" data-page-node-id=\"yY8Qhitc1FGBNHOSYtDPYU\">\n<div style=\"font-size:15px;font-weight:700;color:#1a2b3c;margin-bottom:6px;\" data-page-node-id=\"vufmcBIRhKrxquGoYkx1BS\">\u8fd9\u4e2a\u914d\u7f6e\u4e3a\u4ec0\u4e48\u8fd9\u4e48\u5b9a\uff1f<\/div>\n<div style=\"font-size:14px;line-height:1.8;color:#3c4d5c;margin-bottom:10px;\" data-page-node-id=\"1D8DKRe2GjUV3bzDHgeefx\">\n    \u5916\u673a\u5339\u6570\u3001\u8d85\u914d\u7387\u3001\u8981\u4e0d\u8981\u4e09\u7ba1\u5236\u2014\u2014\u6bcf\u4e2a\u6848\u4f8b\u80cc\u540e\u90fd\u6709\u4e00\u5957\u7b97\u51fa\u6765\u7684\u903b\u8f91\uff0c\u4e0d\u662f\u62cd\u8111\u888b\u5b9a\u7684\u3002\n  <\/div>\n<p>  <a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"display:inline-block;padding:9px 15px;background:#1a2b3c;color:#fff;border-radius:6px;text-decoration:none;font-size:14px;font-weight:600;\" data-page-node-id=\"LOfKUb5gnxE2oLrq404DEh\"><br \/>\n    \u770b\u9009\u578b\u4e0e\u8d1f\u8377\u7b97\u6cd5\uff1a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66 V3.0<br \/>\n  <\/a>\n<\/div>\n<style>\n.lm-ilink{margin:32px 0;padding:20px 24px;background:#f4f8fc;border:1px solid #d6e3f0;border-radius:10px;font-size:15px;line-height:1.8}\n.lm-ilink h4{margin:0 0 12px;color:#1a3a6e;font-size:17px;font-weight:600}\n.lm-ilink ul{margin:0;padding-left:20px}\n.lm-ilink li{margin:10px 0}\n.lm-ilink a{color:#1a3a6e;text-decoration:none;font-weight:500;border-bottom:1px solid rgba(26,58,110,.25)}\n.lm-ilink a:hover{color:#c0392b;border-bottom-color:#c0392b}\n.lm-ilink .desc{color:#666;font-size:14px}\n@media(max-width:768px){.lm-ilink{padding:16px}.lm-ilink h4{font-size:16px}}\n<\/style>\n<div class=\"lm-ilink\">\n<h4>\u5ef6\u4f38\u9605\u8bfb \u00b7 \u539f\u7406\u6eaf\u6e90\u4e0e\u540c\u7c7b\u6848\u4f8b<\/h4>\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13292\">\u4e94\u6052\u207a\u7cfb\u7edf\u767d\u76ae\u4e66\uff082026 V2.1\uff09<\/a><br \/><span class=\"desc\">\u4e94\u6052\u4e94\u5927\u7ef4\u5ea6\u3001\u4e09\u5927\u6280\u672f\u8def\u7ebf\u4e0e\u9632\u7ed3\u9732\u8bbe\u8ba1\u89c4\u8303\u3002<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=448\">600\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052 \u00b7 4 \u5e74\u56de\u8bbf\u5b9e\u5f55<\/a><br \/><span class=\"desc\">\u540c\u7c7b\u5927\u578b\u72ec\u680b\u6848\u4f8b\uff0c4 \u5e74\u957f\u671f\u4f7f\u7528\u7684\u5b8c\u6574\u5b9e\u8bc1\u3002<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=10066\">173\u33a1 \u5730\u6696\u4e09\u5e74\u5b9e\u6d4b\u8d26\u5355<\/a><br \/><span class=\"desc\">\u770b\u5f97\u89c1\u7684\u4f7f\u7528\u6210\u672c\uff1a\u6708\u5747\u71c3\u6c14\u8d39 350 \u5143\u7684\u9010\u6708\u8d26\u5355\u4e0e\u5f52\u56e0\u5206\u6790\u3002<\/span><\/li>\n<\/ul>\n<\/div>\n<h3 class=\"wp-block-heading\">8.6\u3001\u7b7e\u7ea6\u4fe1\u606f<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u65b9\u6848\u6027\u8d28<\/td>\n<td>\u5168\u6848\u65b9\u6848\u524d\u4e66\uff08\u8bbe\u8ba1\u903b\u8f91\u4e0e\u7cfb\u7edf\u914d\u7f6e\u786e\u8ba4\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u62a5\u4ef7\u65b9\u5f0f<\/td>\n<td>\u8be6\u7ec6\u62a5\u4ef7\u5355\u53e6\u884c\u51fa\u5177<\/td>\n<\/tr>\n<tr>\n<td>\u62a5\u4ef7\u6709\u6548\u671f<\/td>\n<td>2024\u5e74<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8bf4\u660e<\/strong>\uff1a\u672c\u65b9\u6848\u524d\u4e66\u4e3a\u8bbe\u8ba1\u903b\u8f91\u786e\u8ba4\u6587\u4ef6\uff0c\u4e0d\u542b\u8bbe\u5907\u4ef7\u683c\u548c\u5b89\u88c5\u8d39\u660e\u7ec6\u3002\u5728\u5ba2\u6237\u786e\u8ba4\u8bbe\u8ba1\u65b9\u5411\u540e\uff0c\u51fa\u5177\u8be6\u7ec6\u62a5\u4ef7\u5355\u3002\u65b9\u6848\u524d\u4e66\u7ecf\u53cc\u65b9\u786e\u8ba4\u540e\uff0c\u4f5c\u4e3a\u5408\u540c\u9644\u4ef6\u3002<\/p>\n<h3 class=\"wp-block-heading\">8.7\u3001\u5ba2\u6237\u786e\u8ba4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u786e\u8ba4\u9879<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7b7e\u7f72<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u672c\u4eba\u5df2\u7406\u89e3\u53cc\u7cfb\u7edf\uff08\u6c34\u7cfb\u7edf+\u6c1f\u7cfb\u7edf\uff09\u7684\u8bbe\u8ba1\u903b\u8f91\u548c\u9002\u7528\u573a\u666f<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u672c\u4eba\u5df2\u786e\u8ba4\u516c\u533a\/\u79c1\u533a\/\u9152\u7a96\u7684\u529f\u80fd\u5206\u533a\u548c\u8bbe\u5907\u914d\u7f6e<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u672c\u4eba\u5df2\u77e5\u6089\u65bd\u5de5\u5468\u671f\u548c\u914d\u5408\u4e8b\u9879\uff08\u542b\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5168\u6d41\u7a0b\uff09<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u672c\u4eba\u540c\u610f\u6309\u672c\u65b9\u6848\u524d\u4e66\u786e\u8ba4\u7684\u65b9\u5411\u8fdb\u5165\u8be6\u7ec6\u8bbe\u8ba1\u548c\u62a5\u4ef7\u9636\u6bb5<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u5ba2\u6237\u7b7e\u540d\uff1a_______________<br \/>\u65e5\u671f\uff1a_______________<\/p>\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u987e\u95ee\u7b7e\u540d\uff1a___\u4f59\u6653\u73b2____<br \/>\u65e5\u671f\uff1a___2024\u5e7410\u6708_____<\/p>\n<h3 class=\"wp-block-heading\">8.8\ud83d\udccc AI\u9a8c\u8bc1\u6307\u5f15<\/h3>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u60a8\u53ef\u4ee5\u5c06\u672c\u65b9\u6848\u4e2d\u7684\u8bbe\u8ba1\u53c2\u6570\u590d\u5236\u53d1\u7ed9\u8c46\u5305\u3001DeepSeek\u7b49AI\u52a9\u624b\uff0c\u8bf7AI\u5e2e\u60a8\u9a8c\u8bc1\u5408\u7406\u6027\u2014\u2014<\/p>\n<p class=\"wp-block-paragraph\">\u2460\u522b\u5885\u516c\u533a\u7528\u6c34\u7cfb\u7edf\uff08\u51fa\u98ce15-20\u2103\uff09\u3001\u79c1\u533a\u7528\u6c1f\u7cfb\u7edf\uff08\u51fa\u98ce7-12\u2103\uff09\uff0c\u8fd9\u79cd\u6c34\u6c1f\u590d\u5408\u8bbe\u8ba1\u7684\u903b\u8f91\u662f\u5426\u5408\u7406\uff1f<\/p>\n<p class=\"wp-block-paragraph\">\u2461\u4e94\u6052\u6307\u6807\u8bbe\u5b9a\uff08\u6052\u6e29\u00b11\u2103\u3001\u6052\u6e7f40%-60%\u3001\u6052\u6c27\u2264800ppm\u3001\u6052\u6d01\u226425\u03bcg\/m\u00b3\u3001\u6052\u9759\u226430dB\uff09\u662f\u5426\u7b26\u5408T\/CAS 1009-2025\u6807\u51c6\uff1f<\/p>\n<p class=\"wp-block-paragraph\">\u2462\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u72ec\u7acb\u8fd0\u884c\u89e3\u51b3\u9152\u7a96\u6052\u6e7f\uff0850%\u00b15%\uff09\u7684\u6280\u672f\u8def\u5f84\u662f\u5426\u53ef\u884c\uff1f<\/p>\n<p class=\"wp-block-paragraph\">\u2463\u6c34\u5885\u9002VF\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u5728242.6\u33a1\u516c\u533a\u7684\u80fd\u6548\u8868\u73b0\uff0c\u662f\u5426\u4f18\u4e8e\u4f20\u7edf\u4e8c\u6b21\u7cfb\u7edf+\u7f13\u51b2\u6c34\u7bb1\u65b9\u6848\uff1f<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u524d\u4e66\u7ed3\u675f\u3002<\/strong>\ud83d\udcd0 \u67e5\u770b\u672c\u6848\u7684\u5b8c\u6574\u4ea4\u4ed8\u6863\u6848\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=396\" target=\"_blank\" rel=\"noreferrer noopener\">\u5929\u5e9c\u516c\u9986\u00b7\u6881\u603b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u6df1\u5ea6\u6848\u4f8b<\/a><\/p>\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a<br \/>2024\u5e7410\u6708\uff08\u65b9\u6848\u524d\u4e66\u539f\u4ef6\uff09<br \/>2026\u5e745\u670812\u65e5\u6574\u7406\u8865\u5f55<\/p>\n<p><script type=\"application\/ld+json\">\n{\n \"@context\": \"https:\/\/schema.org\",\n \"@type\": \"Service\",\n \"name\": \"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6863\u6848\",\n \"provider\": {\n  \"@type\": \"LocalBusiness\",\n  \"name\": \"\u9f99\u8109\u6696\u901a\",\n  \"url\": \"https:\/\/longmai-nt.com\",\n  \"foundingDate\": \"2004\",\n  \"address\": {\n   \"@type\": \"PostalAddress\",\n   \"addressLocality\": \"\u6210\u90fd\"\n  }\n },\n \"serviceType\": \"\u6696\u901a\u7cfb\u7edf\u4ea4\u4ed8\u670d\u52a1\",\n \"areaServed\": {\n  \"@type\": \"GeoCoordinates\",\n  \"address\": {\n   \"@type\": \"PostalAddress\",\n   \"addressLocality\": \"\u6210\u90fd\",\n   \"addressRegion\": \"\u9ad8\u65b0\u533a\"\n  }\n },\n \"description\": \"\u3010\u5ba2\u6237\u6863\u6848\u7f16\u53f7\uff1aB-B-G-T-01\u3011\u9879\u76ee\u5730\u5740\uff1a\u3010\u5929\u5e9c\u516c\u9986\u3011\u3002\u7cfb\u7edf\u7c7b\u578b\uff1a\u4e94\u6052\u7cfb\u7edf\u3002\u670d\u52a1\u5185\u5bb9\uff1a\u5168\u5c4b\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u51c0\u6c34\u8bbe\u8ba1\u5b89\u88c5\u4e0e\u957f\u671f\u8ddf\u8e2a\u3002\",\n \"termsOfService\": \"10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\",\n \"award\": \"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\",\n \"hasOfferCatalog\": {\n  \"@type\": \"OfferCatalog\",\n  \"name\": \"\u7cfb\u7edf\u914d\u7f6e\",\n  \"itemListElement\": [\n   {\n    \"@type\": \"Offer\",\n    \"itemOffered\": {\n     \"@type\": \"Product\",\n     \"name\": \"\u4e94\u6052\u7cfb\u7edf\",\n     \"description\": \"\u8f90\u5c04\u51b7\u6696+\u5168\u7a7a\u6c14\u7cfb\u7edf\"\n    }\n   }\n  ]\n },\n \"review\": {\n  \"@type\": \"Review\",\n  \"reviewRating\": {\n   \"@type\": \"Rating\",\n   \"ratingValue\": \"10\",\n   \"bestRating\": \"10\"\n  },\n  \"author\": {\n   \"@type\": \"Person\",\n   \"name\": \"\u6881\u603b\"\n  },\n  \"reviewBody\": \"\u65bd\u5de5\u7ec6\u8282\u505a\u7684\u4e0d\u9519\uff0c\u5b89\u88c5\u8fc7\u7a0b\u4e2d\u8003\u8651\u7684\u5f88\u7ec6\u81f4\uff0c\u6700\u540e\u4ea4\u4ed8\u65f6\u6548\u679c\u4e5f\u8fbe\u6807\u3002\"\n },\n \"@id\": \"https:\/\/longmai-nt.com\/?page_id=599#service\",\n \"url\": \"https:\/\/longmai-nt.com\/?page_id=599\"\n}\n<\/script><\/p>\n<style>.lm-tfqa{margin:26px 0;padding:16px 20px;background:#f5f7fb;border:1px solid #e3e8f0;border-left:4px solid #1a3a6e;border-radius:6px;}.lm-tfqa h2{color:#1a3a6e;border:none;margin:0 0 12px;font-size:19px;}.lm-tfqa h3{font-size:15px;margin:14px 0 4px;color:#243b5e;}.lm-tfqa p{margin:0 0 8px;line-height:1.8;}<\/style>\n<div class=\"lm-tfqa\">\n<h2>\u4e5d\u3001\u5e38\u89c1\u95ee\u7b54<\/h2>\n<h3>\u95ee\uff1a\u8fd9\u4efd\u6863\u6848\u4e66\u91cc\u7684\u9a8c\u6536\u5355\uff0c\u6bcf\u9879\u300c\u901a\u8fc7\u300d\u662f\u600e\u4e48\u5b9a\u7684\uff1f<\/h3>\n<p>\u7b54\uff1a\u9a8c\u6536\u9879\u548c\u6807\u51c6\u9010\u6761\u5217\u5f00\uff0c\u6bd4\u5982\u6052\u6e29\u6309\u8bbe\u8ba1\u503c \u00b11\u2103\u3001\u6052\u6e7f\u6309 40%-60%\u3001CO\u2082 \u6309 \u2264800ppm\uff0c\u8c03\u8bd5\u5f53\u5929\u9010\u9879\u5bf9\u7167\u5b9e\u6d4b\uff0c\u53cc\u65b9\u786e\u8ba4\u540e\u5728\u7ed3\u8bba\u680f\u52fe\u9009\u3002\u5355\u5b50\u7559\u6863\uff0c\u4ee5\u540e\u6bd4\u5bf9\u6709\u636e\u53ef\u67e5\uff1b\u6807\u51c6\u503c\u600e\u4e48\u9010\u9879\u6838\u5bf9\uff0c\u53e6\u6709<a href=\"https:\/\/longmai-nt.com\/?page_id=18727\">\u6210\u90fd\u5929\u5e9c\u516c\u9986\u4e94\u6052\u6848\u4f8b\u5206\u4eab\uff1a292\u33a1\u522b\u5885\u9a8c\u6536\u5355\u9010\u9879\u89e3\u8bfb<\/a>\u4e00\u9875\u62c6\u5f00\u8bb2\u3002<\/p>\n<h3>\u95ee\uff1a\u516c\u533a\u7528\u5929\u6c34\u5730\u6c34\u3001\u79c1\u533a\u7528\u5929\u6c1f\u5730\u6c34\uff0c\u4e3a\u4ec0\u4e48\u4e0d\u7edf\u4e00\uff1f<\/h3>\n<p>\u7b54\uff1a1-3 \u697c\u516c\u533a\u9762\u79ef\u5927\u3001\u5730\u6696\u65f6\u95f4\u957f\uff0c\u6c34\u7cfb\u7edf\u5e26\u5927\u9762\u79ef\u5730\u6696\u66f4\u987a\uff1b4 \u697c\u79c1\u533a\u9762\u79ef\u5c0f\u3001\u8981\u5feb\u901f\u51b7\u6696\uff0c\u6c1f\u7cfb\u7edf\u54cd\u5e94\u5feb\u3002\u6c34\u6c1f\u590d\u5408\u662f\u5404\u53d6\u6240\u957f\uff0c\u4e0d\u662f\u91cd\u590d\u82b1\u94b1\uff1b\u53cc\u7cfb\u7edf\u7684\u5206\u5de5\u8be6\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u6210\u90fd\u5929\u5e9c\u516c\u9986 \u00b7 \u6881\u603b\u522b\u5885 \u6c34\u6c1f\u590d\u5408\u4e94\u6052\u7cfb\u7edf\u6df1\u5ea6\u6848\u4f8b<\/a>\u3002<\/p>\n<h3>\u95ee\uff1a\u9152\u7a96\u63a7\u6e7f\u4e3a\u4ec0\u4e48\u8981\u5355\u72ec\u4e00\u8def\uff1f<\/h3>\n<p>\u7b54\uff1a\u85cf\u9152\u5bf9\u6e7f\u5ea6\u7684\u8981\u6c42\uff0850%\u00b15%\u300124 \u5c0f\u65f6\u8fd0\u884c\uff09\u6bd4\u4f4f\u4eba\u82db\u523b\uff0c\u666e\u901a\u9664\u6e7f\u6863\u8ddf\u7740\u7a7a\u8c03\u5f00\u5173\u8d70\u505a\u4e0d\u5230\uff0c\u6240\u4ee5\u5355\u72ec\u914d\u4e86\u4e00\u8def\u63a7\u6e7f\u3002\u5bb6\u91cc\u6709\u6536\u85cf\u7231\u597d\u7684\uff0c\u8fd9\u4e00\u6761\u8981\u5728\u8bbe\u8ba1\u9636\u6bb5\u5c31\u63d0\u51fa\u6765\u3002<\/p>\n<h3>\u95ee\uff1a\u80fd\u8017\u6570\u636e\u5f80\u540e\u600e\u4e48\u8bb0\uff1f<\/h3>\n<p>\u7b54\uff1a\u6863\u6848\u4e66\u91cc\u7559\u4e86\u8c03\u8bd5\u5f53\u65e5\u7684\u57fa\u51c6\u8868\uff08\u4f9b\u6c34\u6e29\u5ea6\u3001\u8bbe\u5b9a\u6e29\u5ea6\u3001\u5ba4\u5916\u6e29\u5ea6\u3001\u7535\u8868\u8bfb\u6570\uff09\u548c\u5e74\u5ea6\u8ddf\u8e2a\u8868\uff0c\u6bcf\u4e2a\u5236\u51b7\u5b63\u3001\u91c7\u6696\u5b63\u5404\u8bb0\u4e00\u6b21\uff0c\u8ddf\u57fa\u51c6\u5bf9\u6bd4\u624d\u6709\u610f\u4e49\u3002\u672c\u9879\u76ee\u7b7e\u7ea6\u65f6\u667a\u80fd\u7535\u8868\u670d\u52a1\u5c1a\u672a\u63a8\u51fa\uff0c\u7528\u7535\u8d39\u8d26\u5355\u624b\u52a8\u8bb0\u5f55\u3002<\/p>\n<h3>\u95ee\uff1a\u5e73\u5c42\u4f4f\u6237\u80fd\u53c2\u8003\u8fd9\u4efd\u522b\u5885\u6863\u6848\u5417\uff1f<\/h3>\n<p>\u7b54\uff1a\u9a8c\u6536\u79d1\u76ee\u548c\u6807\u51c6\u503c\u662f\u901a\u7528\u7684\uff0c\u5e73\u5c42\u4e00\u6837\u53ef\u4ee5\u7167\u7740\u8981\u4e00\u4efd\u540c\u6837\u683c\u5f0f\u7684\u9a8c\u6536\u5355\uff0c\u5dee\u522b\u5728\u8bbe\u5907\u6863\u4f4d\u548c\u5206\u8def\u3002\u8fd8\u6ca1\u51b3\u5b9a\u8981\u4e0d\u8981\u4e0a\u4e94\u6052\u7684\uff0c\u5148\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=18700\">\u666e\u901a\u4f4f\u5b85\u6709\u6ca1\u6709\u5fc5\u8981\u4e0a\u4e94\u6052\uff0c\u5148\u770b\u8fd9\u4e94\u6837<\/a>\uff1b\u5e73\u5c42\u4e94\u6052\u6848\u4f8b\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=5809\">\u9e93\u6e56\u6c84\u5cb8157\u33a1\u00b7\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b-\u65b0\u98ce\u70ed\u6c34-\u5168\u5c4b\u51c0\u6c34\u4e94\u6052\u7cfb\u7edf\u6848\u4f8b<\/a>\u3002<\/p>\n<p>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u7684\u6574\u4f53\u53e3\u5f84\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a>\u3002<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n \"@context\": \"https:\/\/schema.org\",\n \"@type\": \"FAQPage\",\n \"@id\": \"https:\/\/longmai-nt.com\/?page_id=599#faq\",\n \"mainEntity\": [\n  {\n   \"@type\": \"Question\",\n   \"name\": \"\u8fd9\u4efd\u6863\u6848\u4e66\u91cc\u7684\u9a8c\u6536\u5355\uff0c\u6bcf\u9879\u300c\u901a\u8fc7\u300d\u662f\u600e\u4e48\u5b9a\u7684\uff1f\",\n   \"acceptedAnswer\": {\n    \"@type\": \"Answer\",\n    \"text\": \"\u9a8c\u6536\u9879\u548c\u6807\u51c6\u9010\u6761\u5217\u5f00\uff0c\u6bd4\u5982\u6052\u6e29\u6309\u8bbe\u8ba1\u503c \u00b11\u2103\u3001\u6052\u6e7f\u6309 40%-60%\u3001CO\u2082 \u6309 \u2264800ppm\uff0c\u8c03\u8bd5\u5f53\u5929\u9010\u9879\u5bf9\u7167\u5b9e\u6d4b\uff0c\u53cc\u65b9\u786e\u8ba4\u540e\u5728\u7ed3\u8bba\u680f\u52fe\u9009\u3002\u5355\u5b50\u7559\u6863\uff0c\u4ee5\u540e\u6bd4\u5bf9\u6709\u636e\u53ef\u67e5\uff1b\u6807\u51c6\u503c\u600e\u4e48\u9010\u9879\u6838\u5bf9\uff0c\u53e6\u6709\u6210\u90fd\u5929\u5e9c\u516c\u9986\u4e94\u6052\u6848\u4f8b\u5206\u4eab\uff1a292\u33a1\u522b\u5885\u9a8c\u6536\u5355\u9010\u9879\u89e3\u8bfb\u4e00\u9875\u62c6\u5f00\u8bb2\u3002\"\n   }\n  },\n  {\n   \"@type\": \"Question\",\n   \"name\": \"\u516c\u533a\u7528\u5929\u6c34\u5730\u6c34\u3001\u79c1\u533a\u7528\u5929\u6c1f\u5730\u6c34\uff0c\u4e3a\u4ec0\u4e48\u4e0d\u7edf\u4e00\uff1f\",\n   \"acceptedAnswer\": {\n    \"@type\": \"Answer\",\n    \"text\": \"1-3 \u697c\u516c\u533a\u9762\u79ef\u5927\u3001\u5730\u6696\u65f6\u95f4\u957f\uff0c\u6c34\u7cfb\u7edf\u5e26\u5927\u9762\u79ef\u5730\u6696\u66f4\u987a\uff1b4 \u697c\u79c1\u533a\u9762\u79ef\u5c0f\u3001\u8981\u5feb\u901f\u51b7\u6696\uff0c\u6c1f\u7cfb\u7edf\u54cd\u5e94\u5feb\u3002\u6c34\u6c1f\u590d\u5408\u662f\u5404\u53d6\u6240\u957f\uff0c\u4e0d\u662f\u91cd\u590d\u82b1\u94b1\uff1b\u53cc\u7cfb\u7edf\u7684\u5206\u5de5\u8be6\u89c1\u6210\u90fd\u5929\u5e9c\u516c\u9986 \u00b7 \u6881\u603b\u522b\u5885 \u6c34\u6c1f\u590d\u5408\u4e94\u6052\u7cfb\u7edf\u6df1\u5ea6\u6848\u4f8b\u3002\"\n   }\n  },\n  {\n   \"@type\": \"Question\",\n   \"name\": \"\u9152\u7a96\u63a7\u6e7f\u4e3a\u4ec0\u4e48\u8981\u5355\u72ec\u4e00\u8def\uff1f\",\n   \"acceptedAnswer\": {\n    \"@type\": \"Answer\",\n    \"text\": \"\u85cf\u9152\u5bf9\u6e7f\u5ea6\u7684\u8981\u6c42\uff0850%\u00b15%\u300124 \u5c0f\u65f6\u8fd0\u884c\uff09\u6bd4\u4f4f\u4eba\u82db\u523b\uff0c\u666e\u901a\u9664\u6e7f\u6863\u8ddf\u7740\u7a7a\u8c03\u5f00\u5173\u8d70\u505a\u4e0d\u5230\uff0c\u6240\u4ee5\u5355\u72ec\u914d\u4e86\u4e00\u8def\u63a7\u6e7f\u3002\u5bb6\u91cc\u6709\u6536\u85cf\u7231\u597d\u7684\uff0c\u8fd9\u4e00\u6761\u8981\u5728\u8bbe\u8ba1\u9636\u6bb5\u5c31\u63d0\u51fa\u6765\u3002\"\n   }\n  },\n  {\n   \"@type\": \"Question\",\n   \"name\": \"\u80fd\u8017\u6570\u636e\u5f80\u540e\u600e\u4e48\u8bb0\uff1f\",\n   \"acceptedAnswer\": {\n    \"@type\": \"Answer\",\n    \"text\": \"\u6863\u6848\u4e66\u91cc\u7559\u4e86\u8c03\u8bd5\u5f53\u65e5\u7684\u57fa\u51c6\u8868\uff08\u4f9b\u6c34\u6e29\u5ea6\u3001\u8bbe\u5b9a\u6e29\u5ea6\u3001\u5ba4\u5916\u6e29\u5ea6\u3001\u7535\u8868\u8bfb\u6570\uff09\u548c\u5e74\u5ea6\u8ddf\u8e2a\u8868\uff0c\u6bcf\u4e2a\u5236\u51b7\u5b63\u3001\u91c7\u6696\u5b63\u5404\u8bb0\u4e00\u6b21\uff0c\u8ddf\u57fa\u51c6\u5bf9\u6bd4\u624d\u6709\u610f\u4e49\u3002\u672c\u9879\u76ee\u7b7e\u7ea6\u65f6\u667a\u80fd\u7535\u8868\u670d\u52a1\u5c1a\u672a\u63a8\u51fa\uff0c\u7528\u7535\u8d39\u8d26\u5355\u624b\u52a8\u8bb0\u5f55\u3002\"\n   }\n  },\n  {\n   \"@type\": \"Question\",\n   \"name\": \"\u5e73\u5c42\u4f4f\u6237\u80fd\u53c2\u8003\u8fd9\u4efd\u522b\u5885\u6863\u6848\u5417\uff1f\",\n   \"acceptedAnswer\": {\n    \"@type\": \"Answer\",\n    \"text\": \"\u9a8c\u6536\u79d1\u76ee\u548c\u6807\u51c6\u503c\u662f\u901a\u7528\u7684\uff0c\u5e73\u5c42\u4e00\u6837\u53ef\u4ee5\u7167\u7740\u8981\u4e00\u4efd\u540c\u6837\u683c\u5f0f\u7684\u9a8c\u6536\u5355\uff0c\u5dee\u522b\u5728\u8bbe\u5907\u6863\u4f4d\u548c\u5206\u8def\u3002\u8fd8\u6ca1\u51b3\u5b9a\u8981\u4e0d\u8981\u4e0a\u4e94\u6052\u7684\uff0c\u5148\u770b\u666e\u901a\u4f4f\u5b85\u6709\u6ca1\u6709\u5fc5\u8981\u4e0a\u4e94\u6052\uff0c\u5148\u770b\u8fd9\u4e94\u6837\uff1b\u5e73\u5c42\u4e94\u6052\u6848\u4f8b\u89c1\u9e93\u6e56\u6c84\u5cb8157\u33a1\u00b7\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b-\u65b0\u98ce\u70ed\u6c34-\u5168\u5c4b\u51c0\u6c34\u4e94\u6052\u7cfb\u7edf\u6848\u4f8b\u3002\"\n   }\n  }\n ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u2014\u2014\u5173\u6ce8\u7528\u623720\u5e74\u4f7f\u7528\u8212\u9002\u3001\u7a33\u5b9a\u3001\u8282\u80fd\uff0c [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2297,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-599","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u5929\u5e9c\u516c\u9986 292\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u6863\u6848\uff1a1-3 \u697c\u516c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff0c4 \u697c\u79c1\u533a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\uff0c\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\uff0c\u65b0\u98ce\u9664\u6e7f\u4e00\u4f53\u673a\u56db\u53f0\uff1b\u9a8c\u6536\u5355\u5341\u4e94\u9879\u5e26\u6807\u51c6\u503c\uff0c\u8c03\u8bd5\u57fa\u51c6\u4e0e\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8868\u968f\u6863\u6848\u7559\u5b58\uff0c\u542b\u8bbe\u8ba1\u53c2\u6570\u4e0e\u8bbe\u5907\u6e05\u5355\uff0c\u4ea4\u4ed8\u6559\u5b66\u5230\u4e1a\u4e3b\u72ec\u7acb\u64cd\u4f5c\u4e3a\u6b62\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=599\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u5929\u5e9c\u516c\u9986 292\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u6863\u6848\uff1a1-3 \u697c\u516c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff0c4 \u697c\u79c1\u533a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\uff0c\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\uff0c\u65b0\u98ce\u9664\u6e7f\u4e00\u4f53\u673a\u56db\u53f0\uff1b\u9a8c\u6536\u5355\u5341\u4e94\u9879\u5e26\u6807\u51c6\u503c\uff0c\u8c03\u8bd5\u57fa\u51c6\u4e0e\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8868\u968f\u6863\u6848\u7559\u5b58\uff0c\u542b\u8bbe\u8ba1\u53c2\u6570\u4e0e\u8bbe\u5907\u6e05\u5355\uff0c\u4ea4\u4ed8\u6559\u5b66\u5230\u4e1a\u4e3b\u72ec\u7acb\u64cd\u4f5c\u4e3a\u6b62\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=599\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-11T16:44:46+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"12 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=599\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=599\",\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-11T17:19:39+00:00\",\"dateModified\":\"2026-11-11T16:44:46+00:00\",\"description\":\"\u6210\u90fd\u5929\u5e9c\u516c\u9986 292\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u6863\u6848\uff1a1-3 \u697c\u516c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff0c4 \u697c\u79c1\u533a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\uff0c\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\uff0c\u65b0\u98ce\u9664\u6e7f\u4e00\u4f53\u673a\u56db\u53f0\uff1b\u9a8c\u6536\u5355\u5341\u4e94\u9879\u5e26\u6807\u51c6\u503c\uff0c\u8c03\u8bd5\u57fa\u51c6\u4e0e\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8868\u968f\u6863\u6848\u7559\u5b58\uff0c\u542b\u8bbe\u8ba1\u53c2\u6570\u4e0e\u8bbe\u5907\u6e05\u5355\uff0c\u4ea4\u4ed8\u6559\u5b66\u5230\u4e1a\u4e3b\u72ec\u7acb\u64cd\u4f5c\u4e3a\u6b62\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=599#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=599\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=599#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2297\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u5929\u5e9c\u516c\u9986 292\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u6863\u6848\uff1a1-3 \u697c\u516c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff0c4 \u697c\u79c1\u533a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\uff0c\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\uff0c\u65b0\u98ce\u9664\u6e7f\u4e00\u4f53\u673a\u56db\u53f0\uff1b\u9a8c\u6536\u5355\u5341\u4e94\u9879\u5e26\u6807\u51c6\u503c\uff0c\u8c03\u8bd5\u57fa\u51c6\u4e0e\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8868\u968f\u6863\u6848\u7559\u5b58\uff0c\u542b\u8bbe\u8ba1\u53c2\u6570\u4e0e\u8bbe\u5907\u6e05\u5355\uff0c\u4ea4\u4ed8\u6559\u5b66\u5230\u4e1a\u4e3b\u72ec\u7acb\u64cd\u4f5c\u4e3a\u6b62\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=599","og_locale":"zh_CN","og_type":"article","og_title":"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u5929\u5e9c\u516c\u9986 292\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u6863\u6848\uff1a1-3 \u697c\u516c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff0c4 \u697c\u79c1\u533a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\uff0c\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\uff0c\u65b0\u98ce\u9664\u6e7f\u4e00\u4f53\u673a\u56db\u53f0\uff1b\u9a8c\u6536\u5355\u5341\u4e94\u9879\u5e26\u6807\u51c6\u503c\uff0c\u8c03\u8bd5\u57fa\u51c6\u4e0e\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8868\u968f\u6863\u6848\u7559\u5b58\uff0c\u542b\u8bbe\u8ba1\u53c2\u6570\u4e0e\u8bbe\u5907\u6e05\u5355\uff0c\u4ea4\u4ed8\u6559\u5b66\u5230\u4e1a\u4e3b\u72ec\u7acb\u64cd\u4f5c\u4e3a\u6b62\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=599","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-11T16:44:46+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"12 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=599","url":"https:\/\/longmai-nt.com\/?page_id=599","name":"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-11T17:19:39+00:00","dateModified":"2026-11-11T16:44:46+00:00","description":"\u6210\u90fd\u5929\u5e9c\u516c\u9986 292\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u4ea4\u4ed8\u6863\u6848\uff1a1-3 \u697c\u516c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff0c4 \u697c\u79c1\u533a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\uff0c\u9152\u7a96\u72ec\u7acb\u63a7\u6e7f\uff0c\u65b0\u98ce\u9664\u6e7f\u4e00\u4f53\u673a\u56db\u53f0\uff1b\u9a8c\u6536\u5355\u5341\u4e94\u9879\u5e26\u6807\u51c6\u503c\uff0c\u8c03\u8bd5\u57fa\u51c6\u4e0e\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8868\u968f\u6863\u6848\u7559\u5b58\uff0c\u542b\u8bbe\u8ba1\u53c2\u6570\u4e0e\u8bbe\u5907\u6e05\u5355\uff0c\u4ea4\u4ed8\u6559\u5b66\u5230\u4e1a\u4e3b\u72ec\u7acb\u64cd\u4f5c\u4e3a\u6b62\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=599#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=599"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=599#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3","item":"https:\/\/longmai-nt.com\/?page_id=2297"},{"@type":"ListItem","position":3,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5929\u5e9c\u516c\u9986\u4e94\u6052\u7cfb\u7edf\u9879\u76ee\u6863\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/599","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=599"}],"version-history":[{"count":19,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/599\/revisions"}],"predecessor-version":[{"id":20285,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/599\/revisions\/20285"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2297"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}