{"id":6173,"date":"2026-07-11T12:24:17","date_gmt":"2026-07-11T04:24:17","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=6173"},"modified":"2026-07-11T12:29:02","modified_gmt":"2026-07-11T04:29:02","slug":"%e5%91%a8%e5%a5%b3%e5%a3%ab%e7%9a%84%e6%97%a5%e7%ab%8b%e5%b0%8a%e7%9d%bf%e5%85%a8%e6%95%88%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e4%ba%8c%e8%81%94%e4%be%9b%e6%96%b9%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=6173","title":{"rendered":"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66"},"content":{"rendered":"\n<style>\n*{margin:0;padding:0;box-sizing:border-box}\nbody{font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;background:#f5f7fa;color:#2d3436;line-height:1.8}\n.cover{background:linear-gradient(135deg,#1a3a5c 0%,#2c5f8a 60%,#457b9d 100%);color:#fff;border-radius:16px;padding:50px 40px;text-align:center;margin-bottom:40px;max-width:950px;margin-left:auto;margin-right:auto}\n.cover h1{font-size:32px;margin-bottom:8px}.cover .sub{font-size:18px;opacity:.88;margin-bottom:4px}\n.cover .tag{display:inline-block;background:rgba(255,255,255,.2);border-radius:20px;padding:6px 20px;font-size:13px;margin-top:12px}\n.cover .hot{display:inline-block;background:#c62828;border-radius:20px;padding:5px 16px;font-size:13px;margin-left:8px}\n.cover .meta{font-size:14px;opacity:.7;margin-top:16px}\n.sec{background:#fff;border-radius:14px;padding:32px;margin-bottom:24px;box-shadow:0 2px 12px rgba(0,0,0,.06);max-width:950px;margin-left:auto;margin-right:auto}\n.sec h2{font-size:22px;font-weight:700;color:#1a3a5c;margin-bottom:18px;padding-bottom:10px;border-bottom:2px solid #e8ecf1}\n.sec h3{font-size:17px;color:#2176c9;border-left:4px solid #2176c9;padding-left:12px;margin:22px 0 12px}\n.info-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;background:#f0f6fc;border-radius:12px;padding:20px 24px;margin:14px 0}\n.info-item .lbl{font-size:12px;color:#888;margin-bottom:2px}\n.info-item .val{font-size:15px;font-weight:600;color:#1a3a5c}\ntable{width:100%;border-collapse:collapse;font-size:14px;margin:14px 0}\nthead th{background:#1a3a5c;color:#fff;padding:10px 14px;text-align:left;font-weight:600}\ntbody td{padding:8px 14px;border-bottom:1px solid #e8ecf1}\ntbody tr:nth-child(even) td{background:#faf8f5}\n.price-total td{background:#1a3a5c!important;color:#fff!important;font-weight:800;font-size:17px!important}\n.adv-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:14px;margin:14px 0}\n.adv-card{background:#faf8f5;border:1px solid #e0d6c8;border-radius:10px;padding:18px;text-align:center}\n.adv-card .ai{font-size:28px;margin-bottom:6px}.adv-card .at{font-size:15px;font-weight:700;color:#1a3a5c;margin-bottom:4px}\n.adv-card .ad{font-size:13px;color:#555;line-height:1.6}\n.quote{background:#f0f6fc;border-left:4px solid #2176c9;border-radius:0 8px 8px 0;padding:14px 18px;margin:12px 0;font-size:14px;color:#666}\n.quote strong{color:#1a3a5c}\n@media(max-width:768px){.info-grid,.adv-grid{grid-template-columns:1fr}}\n<\/style>\n\n\n\n<div style=\"background:linear-gradient(135deg,#1a3a5c 0%,#2c5f8a 60%,#457b9d 100%);color:#fff;border-radius:16px;padding:50px 40px;text-align:center;margin:0 auto 40px;max-width:950px\">\n  <h1 style=\"font-size:32px;margin-bottom:8px;color:#fff\">\u5b9c\u5bbe\u5468\u59d0 \u00b7 \u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u65b9\u6848\u4e66<\/h1>\n  <p style=\"font-size:18px;opacity:.88;margin-bottom:4px\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548335\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b | 280\u33a1\u5927\u5b85 \u00b7 \u5168\u5c4b\u5730\u6696 \u00b7 \u65b0\u98ce\u7cfb\u7edf<\/p>\n  <span style=\"display:inline-block;background:rgba(255,255,255,.2);border-radius:20px;padding:6px 20px;font-size:13px;margin-top:12px\">\ud83c\udf0a \u5929\u6c1f\u5730\u6c34\u5168\u6848<\/span>\n  <span style=\"display:inline-block;background:#c62828;border-radius:20px;padding:5px 16px;font-size:13px;margin-left:8px\">\ud83d\udd25 \u4e94\u6052\u8fdb\u9636<\/span>\n  <p style=\"font-size:14px;opacity:.7;margin-top:16px\">\u65b9\u6848\u987e\u95ee\uff1a\u90ed\u52c7\u79c0 \u00b7 \u9f99\u8109\u6696\u901a \u00b7 2026\u5e747\u670810\u65e5<\/p>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83d\udccb \u5ba2\u6237\u4fe1\u606f\u5361<\/h2>\n  <p><strong>\u5b9c\u5bbe\u5468\u59d0<\/strong> \u2014 280\u33a1\u5927\u5b85\uff0c\u5e38\u4f4f5\u4eba\u3002\u5df2\u5bf9\u6bd4\u5927\u91d1\u3001\u7ea6\u514b\u3001\u65e5\u7acb\u4e09\u4e2a\u54c1\u724c\u3002\u9700\u8981\u4e00\u5957\u8212\u9002\u3001\u7a33\u5b9a\u3001\u8282\u80fd\u7684\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u8054\u4f9b\u7cfb\u7edf\u3002<\/p>\n  <div class=\"info-grid\">\n    <div class=\"info-item\"><div class=\"lbl\">\u5ba2\u6237<\/div><div class=\"val\">\u5468\u59d0<\/div><\/div>\n    <div class=\"info-item\"><div class=\"lbl\">\u9879\u76ee\u5730\u5740<\/div><div class=\"val\">\u5b9c\u5bbe<\/div><\/div>\n    <div class=\"info-item\"><div class=\"lbl\">\u5efa\u7b51\u9762\u79ef<\/div><div class=\"val\">\u7ea6280\u33a1<\/div><\/div>\n    <div class=\"info-item\"><div class=\"lbl\">\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"val\">\u7ea6208\u33a1<\/div><\/div>\n    <div class=\"info-item\"><div class=\"lbl\">\u5e38\u4f4f\u4eba\u53e3<\/div><div class=\"val\">5\u4eba<\/div><\/div>\n    <div class=\"info-item\"><div class=\"lbl\">\u5df2\u5bf9\u6bd4\u54c1\u724c<\/div><div class=\"val\">\u5927\u91d1 \u00b7 \u7ea6\u514b \u00b7 \u65e5\u7acb<\/div><\/div>\n  <\/div>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83d\udcd0 \u5404\u623f\u95f4\u9762\u79ef\u4e0e\u5185\u673a\u914d\u7f6e<\/h2>\n  <table>\n    <thead><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u5ba2\u9910\u5385+\u53a8\u623f+\u8fc7\u9053+\u9633\u53f0<\/td><td><strong>127\u33a1<\/strong><\/td><td>RPIZ-80FSVN2QB\/PC \u00d7 3<\/td><td>8.0kW\u00d73<\/td><td>\u4e3b\u8981\u6d3b\u52a8\u533a<\/td><\/tr>\n      <tr><td>\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td><strong>36\u33a1<\/strong><\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>7.1kW<\/td><td>\u26a0\ufe0f \u897f\u6652<\/td><\/tr>\n      <tr><td>\u5367\u5ba4A\uff08\u5957\u623f\uff09<\/td><td><strong>22\u33a1<\/strong><\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4.0kW<\/td><td>\u26a0\ufe0f \u4e66\u623f\u5f53\u6652<\/td><\/tr>\n      <tr><td>\u5367\u5ba4B<\/td><td><strong>11\u33a1<\/strong><\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2kW<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u5367\u5ba4C<\/td><td><strong>12\u33a1<\/strong><\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2.5kW<\/td><td>\u2014<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:13px;color:#999\">\u8d85\u914d\u7387\uff1a118.8% \u2705 \u5408\u7406\u5339\u914d\uff08\u2264130%\uff09\u00b7 \u4e00\u62d6\u4e03 \u00b7 \u4e09\u7ba1\u5236\u6e29\u5ba4\u53cc\u63a7\u5185\u673a<\/p>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83c\udfd7\ufe0f \u7cfb\u7edf\u67b6\u6784<\/h2>\n  <div style=\"background:#f0f6fc;border-radius:12px;padding:24px;font-size:14px;line-height:2.2;font-family:monospace\">\n    \u65e5\u7acb\u5c0a\u777f\u5168\u6548335\u5916\u673a<br>\n    &nbsp;&nbsp;&nbsp;\u251c\u2500\u2500 \u4e09\u7ba1\u5236\u6e29\u5ba4\u53cc\u63a7\u5185\u673a \u00d7 7\u53f0\uff08\u7a7a\u8c03\u672b\u7aef\uff09<br>\n    &nbsp;&nbsp;&nbsp;\u2502&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;\u2514\u2500\u2500 \u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668 \u00d7 7\u4e2a<br>\n    &nbsp;&nbsp;&nbsp;\u251c\u2500\u2500 \u5c0a\u777f\u5168\u6548\u6c34\u6a21\u5757 RWMG-335FWXNZQ\uff08\u5730\u6696\u70ed\u6e90\uff09<br>\n    &nbsp;&nbsp;&nbsp;\u2502&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;\u2514\u2500\u2500 \u4f1f\u661f\u5730\u6696\u7cfb\u7edf\uff0850\u4e3b\u7ba1+20\u76d8\u7ba1+2\u5206\u96c6\u6c34\u5668\uff09<br>\n    &nbsp;&nbsp;&nbsp;\u2514\u2500\u2500 DC\u5168\u70ed\u4ea4\u6362\u65b0\u98ce \u00d7 2\u5957 + 11\u540bAI\u667a\u6167\u5c4f\uff08\u5168\u5c4b\u7a7a\u6c14\u7ba1\u7406\uff09\n  <\/div>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83d\udd0d \u5929\u6c1f\u5730\u6c34 vs \u5929\u6c34\u5730\u6c34 \u00b7 \u6838\u5fc3\u5bf9\u6bd4<\/h2>\n  <div class=\"quote\"><strong>\ud83d\udca1 \u6838\u5fc3\u8bba\u70b9\uff1a<\/strong>\u5929\u6c34\u5730\u6c34\u6709\u7684\u529f\u80fd\uff0c\u5929\u6c1f\u5730\u6c34\u90fd\u6709\uff1b\u5929\u6c1f\u5730\u6c34\u6709\u7684\u529f\u80fd\uff08\u81ea\u6e05\u6d01\u3001\u9ad8\u6e29\u6740\u83cc\u3001\u6e29\u6e7f\u53cc\u63a7\uff09\uff0c\u5929\u6c34\u5730\u6c34\u6ca1\u6709\u3002<\/div>\n  <table>\n    <thead><tr><th>\u7ef4\u5ea6<\/th><th>\ud83c\udf0a \u5929\u6c1f\u5730\u6c34\uff08\u672c\u65b9\u6848\uff09<\/th><th>\ud83d\udca7 \u5929\u6c34\u5730\u6c34<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td><strong>\u7cfb\u7edf\u539f\u7406<\/strong><\/td><td>\u4e00\u6b21\u6362\u70ed\uff0c\u51b7\u5a92\u76f4\u8fde\u5185\u673a<\/td><td>\u4e8c\u6b21\u6362\u70ed\uff0c\u591a\u6c34\u6cf5+\u6362\u70ed\u5668<\/td><\/tr>\n      <tr><td><strong>\u8212\u9002\u6027<\/strong><\/td><td>\u51fa\u98ce\u53ef\u8c03\u81f318\u2103+\u6e29\u6e7f\u53cc\u63a7<\/td><td>\u51fa\u98ce\u67d4\u548c\u4f46\u65e0\u6e29\u6e7f\u53cc\u63a7<\/td><\/tr>\n      <tr><td><strong>\u8282\u80fd\u6027<\/strong><\/td><td>\u4e00\u6b21\u6362\u70ed\uff0c\u5c11\u4e00\u4e2a\u6c34\u6cf5\u635f\u8017<\/td><td>\u6c34\u6cf5\u6301\u7eed\u8fd0\u884c\u635f\u8017<\/td><\/tr>\n      <tr><td><strong>\u81ea\u6e05\u6d01<\/strong><\/td><td>\u2705 \u6807\u914d\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01<\/td><td>\u274c \u65e0<\/td><\/tr>\n      <tr><td><strong>\u9ad8\u6e29\u6740\u83cc<\/strong><\/td><td>\u2705 56\u2103\/30min\u6807\u914d<\/td><td>\u274c \u65e0<\/td><\/tr>\n      <tr><td><strong>\u9664\u6e7f\u4e0d\u964d\u6e29<\/strong><\/td><td>\u2705 \u6807\u914d<\/td><td>\u274c \u65e0<\/td><\/tr>\n      <tr><td><strong>\u7cfb\u7edf\u590d\u6742\u5ea6<\/strong><\/td><td>\u7b80\u6d01\uff0c\u6545\u969c\u70b9\u5c11<\/td><td>\u590d\u6742\uff0c\u6545\u969c\u7387\u9ad8<\/td><\/tr>\n      <tr><td><strong>\u7ef4\u62a4\u6210\u672c<\/strong><\/td><td>\u4f4e\uff0c\u65e0\u51bb\u88c2\u98ce\u9669<\/td><td>\u9ad8\uff0c\u9700\u5b9a\u671f\u6e05\u6d17\u9632\u51bb<\/td><\/tr>\n      <tr><td><strong>\u5382\u5bb6\u8d28\u4fdd<\/strong><\/td><td><strong>10\u5e74<\/strong><\/td><td>\u6807\u51c63~5\u5e74<\/td><\/tr>\n      <tr><td><strong>\u4e94\u6052\u80fd\u529b<\/strong><\/td><td>\u52a0\u65b0\u98ce\u53ef\u5b9e\u73b0\u4e94\u60523.0<\/td><td>\u4e94\u60522.0<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"quote\"><strong>\ud83c\udf1e \u6253\u6d88\u987e\u8651\uff1a<\/strong>\u5929\u6c1f\u5730\u6c34\u51fa\u98ce\u6e29\u5ea6\u53ef\u8c03\u81f318\u2103\uff0c\u8ddf\u6c34\u673a\u4e00\u6837\u6e29\u548c\u3002\u7cfb\u7edf\u66f4\u7b80\u5355\u3001\u6545\u969c\u7387\u66f4\u4f4e\uff0c\u5341\u5e74\u8d28\u4fdd\u3002<\/div>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83d\udcb0 \u8be6\u7ec6\u914d\u7f6e\u4e0e\u62a5\u4ef7<\/h2>\n  <h3>\u2460 \u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\uff08\u5c0a\u777f\u5168\u6548335 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e00\u62d6\u4e03\uff09<\/h3>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7<\/th><th>85\u6298\u540e<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u5916\u673a<\/td><td>RAS-335FSXPN5Q<\/td><td>1\u53f0<\/td><td>38,913<\/td><td>33,076<\/td><\/tr>\n      <tr><td>\u6c34\u6a21\u5757<\/td><td>RWMG-335FWXNZQ<\/td><td>1\u53f0<\/td><td>12,500<\/td><td>10,625<\/td><\/tr>\n      <tr><td>\u5185\u673a80\u578b\u00d73<\/td><td>RPIZ-80FSVN2QB\/PC<\/td><td>3\u53f0<\/td><td>19,314<\/td><td>16,417<\/td><\/tr>\n      <tr><td>\u5185\u673a71\u578b<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,825<\/td><td>4,951<\/td><\/tr>\n      <tr><td>\u5185\u673a40\u578b<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,238<\/td><td>4,452<\/td><\/tr>\n      <tr><td>\u5185\u673a22\u578b<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,050<\/td><td>4,293<\/td><\/tr>\n      <tr><td>\u5185\u673a25\u578b<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,050<\/td><td>4,293<\/td><\/tr>\n      <tr><td>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td>PC-P1HPQA<\/td><td>7\u4e2a<\/td><td>4,116 \ud83d\udeab<\/td><td>4,116<\/td><\/tr>\n      <tr><td>\u5185\u673a\u5b89\u88c5\uff082,100\/\u53f0\uff09<\/td><td>\u2014<\/td><td>7\u53f0<\/td><td>14,700 \ud83d\udeab<\/td><td>14,700<\/td><\/tr>\n      <tr><td>\u4e3b\u673a\u5b89\u88c5<\/td><td>\u2014<\/td><td>1\u5957<\/td><td>500 \ud83d\udeab<\/td><td>500<\/td><\/tr>\n      <tr><td>\u6c34\u6a21\u5757\u5b89\u88c5<\/td><td>\u2014<\/td><td>1\u5957<\/td><td>625 \ud83d\udeab<\/td><td>625<\/td><\/tr>\n      <tr class=\"price-total\"><td colspan=\"4\"><strong>\u2705 \u7a7a\u8c03\u7cfb\u7edf\u5c0f\u8ba1<\/strong><\/td><td><strong>\u00a598,048<\/strong><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:12px;color:#999\">\ud83d\udeab = \u7ebf\u63a7\u5668\/\u5b89\u88c5\u8d39\u4e0d\u6253\u6298<\/p>\n\n  <h3>\u2461 \u5730\u6696\u7cfb\u7edf\uff08\u4f1f\u661f\uff09<\/h3>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u9762\u79ef<\/th><th>\u91d1\u989d<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4f1f\u661f\u5730\u6696\uff0850\u4e3b\u7ba1+20\u76d8\u7ba1+2\u5206\u96c6\u6c34\u5668\uff09<\/td><td>179\u5143\/\u33a1<\/td><td>208\u33a1<\/td><td><strong>\u00a537,232<\/strong><\/td><\/tr>\n      <tr class=\"price-total\"><td colspan=\"3\"><strong>\u2705 \u5730\u6696\u5c0f\u8ba1<\/strong><\/td><td><strong>\u00a537,232<\/strong><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3>\u2462 \u65b0\u98ce+AI\u667a\u6167\u5c4f<\/h3>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u91d1\u989d<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>DC\u5168\u70ed\u4ea4\u6362\u5668<\/td><td>KPI-3521Q5\/F 350m\u00b3\/h<\/td><td>2\u5957<\/td><td>16,628 \ud83d\udd39<\/td><\/tr>\n      <tr><td>\u65b0\u98ce\u5b89\u88c5\u8d39<\/td><td>\u2014<\/td><td>2\u5957<\/td><td>11,600 \ud83d\udeab<\/td><\/tr>\n      <tr><td>11\u540bAI\u667a\u6167\u5c4f\uff08\u542b\u5b89\u88c5\uff09<\/td><td>1920\u00d71200 FHD+<\/td><td>1\u4e2a<\/td><td>5,600 \ud83d\udd39<\/td><\/tr>\n      <tr class=\"price-total\"><td colspan=\"3\"><strong>\u2705 \u65b0\u98ce+\u667a\u6167\u5c4f\u5c0f\u8ba1<\/strong><\/td><td><strong>\u00a533,268<\/strong><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:12px;color:#999\">\ud83d\udd39 = \u8bbe\u5907\u603b\u4ef7\u62539\u6298 &nbsp;|&nbsp; \ud83d\udeab = \u5b89\u88c5\u8d39\u4e0d\u6253\u6298<\/p>\n\n  <h3>\u2463 \u603b\u4ef7\u6c47\u603b<\/h3>\n  <table>\n    <thead><tr><th>\u6a21\u5757<\/th><th>\u91d1\u989d<\/th><th>\u5360\u6bd4<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\uff08\u5929\u6c1f\u5730\u6c34\u00b7\u4e00\u62d6\u4e03\uff09<\/td><td>98,048<\/td><td>58%<\/td><\/tr>\n      <tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u4f1f\u661f208\u33a1\uff09<\/td><td>37,232<\/td><td>22%<\/td><\/tr>\n      <tr><td>\u65b0\u98ce+11\u540bAI\u667a\u6167\u5c4f<\/td><td>33,268<\/td><td>20%<\/td><\/tr>\n      <tr><td><strong>\u57fa\u7840\u5408\u8ba1<\/strong><\/td><td><strong>168,548<\/strong><\/td><td>100%<\/td><\/tr>\n      <tr><td>\u8fdc\u7a0b\u670d\u52a1\u8d39\uff08+5%\uff09<\/td><td>+8,427<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u51cf\uff1a\u56fd\u8865<\/td><td>\u20131,500<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u51cf\uff1a\u5382\u5bb6\u4f18\u60e0<\/td><td>\u20132,000<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u51cf\uff1a\u65b0\u98ce\u4f18\u60e0<\/td><td>\u20131,000<\/td><td>\u2014<\/td><\/tr>\n      <tr class=\"price-total\"><td><strong>\u2705 \u6700\u7ec8\u5230\u624b\u4ef7<\/strong><\/td><td><strong>\u00a5172,475<\/strong><\/td><td>\u2014<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:13px;color:#999;text-align:center\">\u9a8c\u8bc1\uff1a168,548 \u00d7 1.05 \u2212 1,500 \u2212 2,000 \u2212 1,000 = 172,475\u5143<\/p>\n  <div class=\"quote\">\n    <strong>\ud83d\udccc \u4ea7\u54c1\u94fe\u63a5\uff1a<\/strong><br>\n    \ud83d\udd17 <a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7cfb\u5217\u4ea7\u54c1\u4ecb\u7ecd \u2192<\/a><br>\n    \ud83d\udd17 <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u65e5\u7acb\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u4ea7\u54c1\u4ecb\u7ecd \u2192<\/a>\n  <\/div>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83c\udf21\ufe0f \u8212\u9002\u6027 \u00b7 \u8282\u80fd\u6027<\/h2>\n  <div class=\"adv-grid\">\n    <div class=\"adv-card\"><div class=\"ai\">\ud83c\udf00<\/div><div class=\"at\">\u51fa\u98ce18\u2103\u67d4\u548c\u4e0d\u523a\u9aa8<\/div><div class=\"ad\">\u51fa\u98ce\u6e29\u5ea6\u53ef\u8c03\u81f318\u2103\uff0c\u6e29\u6e7f\u53cc\u63a7\uff0c\u6e7f\u5ea640%~60%<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udd25<\/div><div class=\"at\">\u5168\u5c4b208\u33a1\u5730\u6696<\/div><div class=\"ad\">\u811a\u6696\u5934\u51c9\uff0c\u6e29\u5dee\u22642\u2103<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\u26a1<\/div><div class=\"at\">\u4e00\u6b21\u6362\u70ed\u66f4\u8282\u80fd<\/div><div class=\"ad\">\u5c11\u4e00\u4e2a\u6c34\u6cf5\u3001\u5c11\u4e00\u9053\u6362\u70ed\uff0c\u65e0\u6301\u7eed\u6c34\u6cf5\u529f\u8017<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udcb0<\/div><div class=\"at\">\u91c7\u6696\u8d39\u7528\u53c2\u8003<\/div><div class=\"ad\">\u7ea6208\u33a1\u5730\u6696\uff0c\u6708\u5747800~1,200\u5143<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83c\udf2c\ufe0f<\/div><div class=\"at\">\u65b0\u98ce\u5168\u5929\u5019\u6362\u6c14<\/div><div class=\"ad\">DC\u5168\u70ed\u4ea4\u6362\u00d72\u5957\uff0c\u5173\u7a97\u4e5f\u6709\u65b0\u9c9c\u7a7a\u6c14<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83e\udd2b<\/div><div class=\"at\">20dB\u56fe\u4e66\u9986\u7ea7\u9759\u97f3<\/div><div class=\"ad\">\u4e0d\u5f71\u54cd\u7761\u7720<\/div><\/div>\n  <\/div>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83d\udd27 \u7cbe\u5de5\u65bd\u5de5\u6807\u51c6<\/h2>\n  <table>\n    <thead><tr><th>\u5de5\u827a\u73af\u8282<\/th><th>\u9f99\u8109\u6807\u51c6<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\ud83d\udd29 \u6c2e\u6c14\u4fdd\u62a4\u710a<\/td><td>\u5145\u6c2e\u710a\u63a5\uff0c\u675c\u7edd\u710a\u6e23\u6c27\u5316<\/td><\/tr>\n      <tr><td>\ud83e\uddea \u6c14\u5bc6\u6027\u6d4b\u8bd5<\/td><td>4.0MPa\u4fdd\u538b24\u5c0f\u65f6\uff0c\u96f6\u6cc4\u6f0f<\/td><\/tr>\n      <tr><td>\ud83d\udca7 \u771f\u7a7a\u5e72\u71e5<\/td><td>\u62bd\u771f\u7a7a\u22654\u5c0f\u65f6<\/td><\/tr>\n      <tr><td>\ud83d\udcd0 \u7ba1\u8def\u5e03\u5c40<\/td><td>BIM\u4e09\u7ef4\u653e\u6837\uff0c\u6a2a\u5e73\u7ad6\u76f4<\/td><\/tr>\n      <tr><td>\ud83e\uddf9 \u9690\u853d\u9a8c\u6536<\/td><td>22\u9879\u68c0\u67e5\u6e05\u5355\uff0c\u5168\u90e8\u901a\u8fc7\u624d\u5c01\u9876<\/td><\/tr>\n      <tr><td>\ud83d\udccb \u4ea4\u4ed8\u57f9\u8bad<\/td><td>\u4e00\u5bf9\u4e00\u4f7f\u7528\u6559\u5b66+\u64cd\u4f5c\u624b\u518c<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83c\udfc5 \u5b98\u65b9\u6388\u6743\u8d44\u8d28<\/h2>\n  <p>\u9f99\u8109\u6696\u901a\u521b\u5efa\u4e8e<strong>2004\u5e74<\/strong>\uff0c22\u5e74\u4e13\u6ce8\u6210\u90fd\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf\u3002\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<strong>\u6210\u90fd\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/strong>\uff0c<strong>2025\u5e74\u5ea6\u94bb\u77f3\u5b89\u88c5\u5546<\/strong>\u3002\u5bf9\u9762\u5927\u91d1\u6362\u4e86\u56db\u4e2a\u8001\u677f\uff0c\u9f99\u8109\u4e00\u76f4\u6ca1\u6362\u8fc7\u3002<\/p>\n<\/div>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n\n<figure class=\"wp-block-image size-medium\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer-208x300.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u5546\"\/><figcaption>\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u5546<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-medium\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u65e5\u7acb\u5b89\u88c5\u7279\u9080\u6388\u6743.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u5546\"\/><figcaption>\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u5546<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-medium\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-gold-203x300.jpg\" alt=\"\u91d1\u724c\u5b89\u88c5\u5546\"\/><figcaption>\u91d1\u724c\u5b89\u88c5\u5546\uff082024\uff09<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-medium\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/\u5fae\u4fe1\u56fe\u7247_20260429153324_59_93-214x300.png\" alt=\"\u94bb\u77f3\u5b89\u88c5\u5546\"\/><figcaption>\u2b50 \u94bb\u77f3\u5b89\u88c5\u5546\uff082025\uff09<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-medium\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-water-214x300.jpg\" alt=\"\u6c34\u5885\u9002\u7ecf\u9500\u6388\u6743\"\/><figcaption>\u6c34\u5885\u9002\u7ecf\u9500\u6388\u6743<\/figcaption><\/figure>\n<\/figure>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83d\udcf8 \u5c0a\u777f\u5168\u6548\u5916\u673a\u5c55\u793a<\/h2>\n  <p style=\"font-size:14px;color:#666;margin-bottom:16px\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u4e09\u7ba1\u5236\u65d7\u8230\u7cfb\u5217 \u00b7 335\u578b\u5916\u673a<\/p>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" alt=\"\u65e5\u7acb\u5c0a\u777f\u5168\u6548II\u5916\u673a\"\/><figcaption>\u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u4e09\u7ba1\u5236\u65d7\u8230\u7cfb\u5217 \u00b7 335\u578b\u5916\u673a<\/figcaption><\/figure>\n\n\n\n<div class=\"sec\">\n  <h2>\ud83c\udfc6 \u4e3a\u4ec0\u4e48\u9009\u9f99\u8109\u6696\u901a<\/h2>\n  <div class=\"adv-grid\">\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udcdc<\/div><div class=\"at\">22\u5e74\u4e13\u6ce8\u6210\u90fd<\/div><div class=\"ad\">\u59cb\u4e8e2004\uff0c\u5bf9\u9762\u5927\u91d1\u6362\u4e86\u56db\u4e2a\u8001\u677f\uff0c\u9f99\u8109\u4e00\u76f4\u6ca1\u6362\u8fc7<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udd27<\/div><div class=\"at\">\u81ea\u5efa\u5de5\u961f\u975e\u5916\u5305<\/div><div class=\"ad\">\u81ea\u6709\u6301\u8bc1\u65bd\u5de5\u56e2\u961f\uff0c22\u5e74\u7ecf\u9a8c\u6c89\u6dc0<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udcf8<\/div><div class=\"at\">\u53ef\u89c6\u5316\u4ea4\u4ed8<\/div><div class=\"ad\">\u65bd\u5de5\u5168\u6d41\u7a0b\u62cd\u7167\u5b58\u8bc1\uff0c\u7ec8\u8eab\u6863\u6848\u53ef\u67e5<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udee1\ufe0f<\/div><div class=\"at\">10\u5e74\u8d28\u4fdd<\/div><div class=\"ad\">\u5382\u5bb610\u5e74\u8d28\u4fdd+\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udcde<\/div><div class=\"at\">2\u5c0f\u65f6\u54cd\u5e94<\/div><div class=\"ad\">\u552e\u540e2\u5c0f\u65f6\u54cd\u5e94\uff0c\u5e02\u533a24\u5c0f\u65f6\u5185\u4e0a\u95e8<\/div><\/div>\n    <div class=\"adv-card\"><div class=\"ai\">\ud83d\udcac<\/div><div class=\"at\">\u8f6c\u4ecb\u7ecd\u738760%+<\/div><div class=\"ad\">\u53e3\u7891\u662f\u6700\u597d\u7684\u5e7f\u544a<\/div><\/div>\n  <\/div>\n<\/div>\n\n\n\n<div style=\"background:linear-gradient(135deg,#1a3a5c,#2c5f8a);color:#fff;border-radius:14px;padding:28px;text-align:center;margin:20px auto;max-width:950px\">\n  <h3 style=\"color:#fff;margin-bottom:6px\">\ud83d\udcde \u65b9\u6848\u54a8\u8be2 \u00b7 \u514d\u8d39\u52d8\u6d4b<\/h3>\n  <p><strong>\u90ed\u52c7\u79c0<\/strong> \u00b7 \u6210\u90fd\u9f99\u8109\u6696\u901a<\/p>\n  <p style=\"font-size:22px;font-weight:700;margin:8px 0\">181-0083-9248<\/p>\n  <p>\ud83d\udccd \u5357\u5bcc\u68ee\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7A348 \u00b7 028-86131795<\/p>\n  <p>\ud83d\udccd \u5317\u5bcc\u68ee\uff1a\u6210\u534e\u533aA\u5e625\u697cA5135 \u00b7 028-65272586<\/p>\n  <p style=\"font-size:12px;opacity:.5;margin-top:10px\">\u5b98\u7f51\uff1a<a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" style=\"color:#fff;text-decoration:underline\">longmai-nt.com<\/a> \u00b7 \u672c\u65b9\u6848\u62a5\u4ef7\u6709\u6548\u671f30\u5929<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5b9c\u5bbe\u5468\u59d0 \u00b7 \u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u65b9\u6848\u4e66 \u65e5 [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6173","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=6173\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5b9c\u5bbe\u5468\u59d0 \u00b7 \u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u65b9\u6848\u4e66 \u65e5 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=6173\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-11T04:29:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer-208x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173\",\"name\":\"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/license-dealer-208x300.jpg\",\"datePublished\":\"2026-07-11T04:24:17+00:00\",\"dateModified\":\"2026-07-11T04:29:02+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/license-dealer.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/license-dealer.jpg\",\"width\":1280,\"height\":1850},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6173#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=6173","og_locale":"zh_CN","og_type":"article","og_title":"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5b9c\u5bbe\u5468\u59d0 \u00b7 \u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u65b9\u6848\u4e66 \u65e5 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=6173","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-11T04:29:02+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer-208x300.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=6173","url":"https:\/\/longmai-nt.com\/?page_id=6173","name":"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=6173#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=6173#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer-208x300.jpg","datePublished":"2026-07-11T04:24:17+00:00","dateModified":"2026-07-11T04:29:02+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=6173#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=6173"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=6173#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg","width":1280,"height":1850},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=6173#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5468\u5973\u58eb\u7684\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7a7a\u8c03\u5730\u6696\u4e8c\u8054\u4f9b\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6173"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6173\/revisions"}],"predecessor-version":[{"id":6176,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6173\/revisions\/6176"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}