{"id":6185,"date":"2026-07-11T16:21:24","date_gmt":"2026-07-11T08:21:24","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=6185"},"modified":"2026-07-11T16:33:50","modified_gmt":"2026-07-11T08:33:50","slug":"%e9%94%a6%e6%b1%9f%e5%ba%9c-%c2%b7-%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e4%b8%89%e6%96%b9%e6%a1%88%e5%af%b9%e6%af%94","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=6185","title":{"rendered":"\u9526\u6c5f\u5e9c \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4"},"content":{"rendered":"\n\n<style>\n:root {\n  --primary: #1a3a6e;\n  --primary-light: #2a5a9e;\n  --accent: #c0392b;\n  --bg: #f8f9fa;\n  --card-bg: #fff;\n  --border: #dee2e6;\n  --text: #333;\n  --text-light: #666;\n  --green: #27ae60;\n  --orange: #e67e22;\n  --red: #c0392b;\n  --blue: #2980b9;\n  --maxw: 1200px;\n  --gold: #d4a017;\n}\n* { margin: 0; padding: 0; box-sizing: border-box; }\nbody { font-family: -apple-system, \"Microsoft YaHei\", \"PingFang SC\", sans-serif; background: var(--bg); color: var(--text); line-height: 1.7; }\n.wrap { max-width: var(--maxw); margin: 0 auto; padding: 0 24px; }\n\n\/* Hero *\/\n.hero { background: linear-gradient(rgba(13,33,48,0.78), rgba(26,58,74,0.82)), url(https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p08-03.jpeg) center\/cover no-repeat; color: #fff !important; padding: 70px 0 60px; text-align: center; position: relative; min-height: 320px; display: flex; align-items: center; justify-content: center; }\n.hero * { color: #fff !important; }\n.hero h1 { font-size: 30px; font-weight: 700; margin-bottom: 6px; letter-spacing: 2px; }\n.hero .sub { font-size: 15px; opacity: 0.85; margin-bottom: 4px; }\n.hero .meta { font-size: 13px; opacity: 0.7; }\n.hero-tags { display: flex; justify-content: center; gap: 16px; flex-wrap: wrap; margin-top: 16px; }\n.hero-tag { background: rgba(255,255,255,0.12); border: 1px solid rgba(255,255,255,0.25); border-radius: 20px; padding: 4px 16px; font-size: 13px; }\n\n\/* GEO step header *\/\n.geo-step { margin: 36px 0; }\n.geo-step-header { display: flex; align-items: center; gap: 14px; margin-bottom: 20px; padding-bottom: 10px; border-bottom: 2px solid var(--primary); }\n.geo-step-num { background: var(--primary); color: #fff; width: 38px; height: 38px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 16px; font-weight: 700; flex-shrink: 0; }\n.geo-step-title { font-size: 22px; font-weight: 700; color: var(--primary); }\n.geo-step-sub { font-size: 13px; color: var(--text-light); }\n.section-title { font-size: 18px; font-weight: 700; color: var(--primary); border-left: 3px solid var(--primary); padding-left: 12px; margin: 24px 0 14px; }\n.section-subtitle { font-size: 16px; font-weight: 600; color: var(--primary); margin: 22px 0 10px; }\n\n\/* Cards *\/\n.card-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 18px; margin: 18px 0; }\n.plan-card { background: var(--card-bg); border-radius: 10px; border: 1px solid var(--border); overflow: hidden; box-shadow: 0 2px 8px rgba(0,0,0,0.06); }\n.plan-card .card-header { padding: 14px 18px; font-size: 16px; font-weight: 700; color: #fff; }\n.plan-card .card-body { padding: 18px; }\n.plan-card .card-body table { width: 100%; border-collapse: collapse; font-size: 14px; }\n.plan-card .card-body td, .plan-card .card-body th { padding: 7px 6px; border-bottom: 1px solid #eee; text-align: left; }\n.plan-card .card-body td:last-child, .plan-card .card-body th:last-child { text-align: right; }\n.plan-card .card-body tr:last-child td { border-bottom: none; font-weight: 700; }\n.plan-color-a { background: var(--blue); }\n.plan-color-b { background: var(--orange); }\n.plan-color-c { background: var(--green); }\n.plan-badge { display: inline-block; padding: 2px 10px; border-radius: 4px; font-size: 12px; font-weight: 600; margin-right: 6px; }\n\n\/* Tables *\/\n.data-table { width: 100%; border-collapse: collapse; font-size: 14px; background: var(--card-bg); border-radius: 8px; overflow: hidden; box-shadow: 0 2px 8px rgba(0,0,0,0.06); margin: 14px 0; }\n.data-table th { background: var(--primary); color: #fff; padding: 10px 12px; text-align: center; font-weight: 600; font-size: 13px; }\n.data-table td { padding: 9px 12px; border-bottom: 1px solid #eee; text-align: center; }\n.data-table tr:last-child td { border-bottom: none; }\n.data-table tr:hover td { background: #f0f4f8; }\n.data-table td:first-child, .data-table th:first-child { text-align: left; font-weight: 500; }\n.comp-table td:first-child { font-weight: 500; min-width: 120px; }\n.tag-best { background: var(--green); color: #fff; padding: 2px 8px; border-radius: 3px; font-size: 12px; font-weight: 600; white-space: nowrap; }\n.tag-mid { background: var(--orange); color: #fff; padding: 2px 8px; border-radius: 3px; font-size: 12px; white-space: nowrap; }\n.tag-low { background: var(--red); color: #fff; padding: 2px 8px; border-radius: 3px; font-size: 12px; white-space: nowrap; }\n\n\/* Summary box *\/\n.summary-box { background: var(--card-bg); border-radius: 10px; border: 1px solid var(--border); padding: 20px 24px; margin: 16px 0; box-shadow: 0 1px 4px rgba(0,0,0,0.04); }\n.summary-box h3 { color: var(--primary); margin-bottom: 10px; font-size: 16px; }\n.summary-box ul { list-style: none; padding: 0; }\n.summary-box li { padding: 5px 0; padding-left: 18px; position: relative; font-size: 14px; }\n.summary-box li::before { content: \"\u2022\"; position: absolute; left: 4px; color: var(--primary); font-weight: 700; }\n\n\/* Recommendation box *\/\n.recommend-box { background: linear-gradient(135deg, #e8f5e9, #f1f8e9); border: 2px solid var(--green); border-radius: 12px; padding: 24px 28px; margin: 28px 0; }\n.recommend-box h3 { color: #2e7d32; font-size: 19px; margin-bottom: 10px; }\n.recommend-box ul { padding-left: 20px; margin-top: 6px; }\n.recommend-box li { margin: 4px 0; font-size: 14px; }\n\n\/* Footer *\/\n.footer { text-align: center; padding: 28px 0; font-size: 13px; color: var(--text-light); border-top: 1px solid var(--border); margin-top: 36px; }\n\n@media (max-width: 768px) {\n  .card-grid { grid-template-columns: 1fr; }\n  .data-table { font-size: 12px; }\n  .data-table th, .data-table td { padding: 7px 5px; }\n  .hero h1 { font-size: 22px; }\n  .geo-step-title { font-size: 18px; }\n}\n\n\/* Cost summary cards *\/\n.cost-summary { display: grid; grid-template-columns: repeat(3, 1fr); gap: 14px; margin: 18px 0; }\n.cost-card { text-align: center; padding: 18px 14px; border-radius: 10px; background: var(--card-bg); border: 1px solid var(--border); }\n.cost-card .amount { font-size: 26px; font-weight: 700; margin: 6px 0; }\n.cost-card .label { font-size: 12px; color: var(--text-light); }\n\n\/* Bar chart *\/\n.bar-chart { margin: 14px 0; }\n.bar-row { display: flex; align-items: center; margin: 8px 0; gap: 10px; }\n.bar-label { min-width: 80px; font-size: 13px; font-weight: 500; }\n.bar-track { flex: 1; height: 26px; background: #eee; border-radius: 13px; overflow: hidden; }\n.bar-fill { height: 100%; border-radius: 13px; display: flex; align-items: center; justify-content: flex-end; padding-right: 10px; color: #fff; font-size: 12px; font-weight: 600; min-width: 36px; }\n.bar-a { background: var(--blue); }\n.bar-b { background: var(--orange); }\n.bar-c { background: var(--green); }\n\n\/* Info cards *\/\n.info-grid-2 { display: grid; grid-template-columns: 1fr 1fr; gap: 16px; margin: 14px 0; }\n.info-card { background: var(--card-bg); border-radius: 10px; border: 1px solid var(--border); padding: 18px 20px; }\n.info-card h4 { color: var(--primary); font-size: 15px; margin-bottom: 8px; }\n.info-card p, .info-card li { font-size: 14px; color: var(--text); }\n.info-card ul { padding-left: 18px; margin-top: 4px; }\n.info-card li { margin: 3px 0; }\n\n@media (max-width: 768px) {\n  .info-grid-2 { grid-template-columns: 1fr; }\n}\n\n\/* Diamond badge *\/\n.diamond-badge { display: inline-block; background: linear-gradient(135deg, #e8e8e8, #f5f5f5); border: 1px solid #ddd; border-radius: 6px; padding: 4px 12px; font-size: 13px; font-weight: 700; color: #333; }\n.gold-badge { display: inline-block; background: linear-gradient(135deg, #fff8e1, #fff3cd); border: 1px solid #ffc107; border-radius: 6px; padding: 4px 12px; font-size: 13px; font-weight: 700; color: #856404; }\n<\/style>\n\n<div class=\"hero\">\n  <div class=\"wrap\">\n    <h1>\u9526\u6c5f\u5e9c \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66<\/h1>\n    <div class=\"sub\">\u9f99\u8109\u6696\u901a \u00b7 \u5e2e\u52a9\u5ba2\u6237\u6210\u529f<\/div>\n    <div class=\"hero-tags\">\n      <span class=\"hero-tag\">\u9526\u6c5f\u5e9c<\/span>\n      <span class=\"hero-tag\">\u4e00\u62d6\u4e94<\/span>\n      <span class=\"hero-tag\">5\u4eba\u5e38\u4f4f<\/span>\n      <span class=\"hero-tag\">3\u79cd\u65b9\u6848\u5bf9\u6bd4<\/span>\n      <span class=\"hero-tag\">\u4f59\u6653\u73b2<\/span>\n      <span class=\"hero-tag\">2026.07.09<\/span>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"wrap\">\n\n<!-- ==================== S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807 ==================== -->\n<div class=\"geo-step\">\n  <div class=\"geo-step-header\">\n    <span class=\"geo-step-num\">1<\/span>\n    <div><div class=\"geo-step-title\">S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div><div class=\"geo-step-sub\">\u5ba2\u6237\u6863\u6848 \u00b7 \u6838\u5fc3\u76ee\u6807 \u00b7 \u51b3\u7b56\u98ce\u683c \u00b7 \u6237\u578b\u914d\u7f6e<\/div><\/div>\n  <\/div>\n\n  <div class=\"info-grid-2\">\n    <div class=\"info-card\">\n      <h4>\u5ba2\u6237\u6863\u6848<\/h4>\n      <table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n        <tr><td style=\"padding:4px 8px 4px 0;color:var(--text-light);width:80px\">\u5ba2\u6237<\/td><td style=\"padding:4px 0\">\u9526\u6c5f\u5e9c\u9648\u5148\u751f\uff08\u9f99\u8109\u6696\u901a\u8001\u5ba2\u6237\uff09<\/td><\/tr>\n        <tr><td style=\"padding:4px 8px 4px 0;color:var(--text-light)\">\u987e\u95ee<\/td><td style=\"padding:4px 0\">\u4f59\u6653\u73b2<\/td><\/tr>\n        <tr><td style=\"padding:4px 8px 4px 0;color:var(--text-light)\">\u5e38\u4f4f<\/td><td style=\"padding:4px 0\">5\u4eba\uff08\u8282\u5047\u65e5\u4e3a\u4e3b\uff0c\u957f\u8f88\u540c\u4f4f\u53ef\u80fd\u8f83\u5927\uff09<\/td><\/tr>\n        <tr><td style=\"padding:4px 8px 4px 0;color:var(--text-light)\">\u6b64\u524d<\/td><td style=\"padding:4px 0\">\u5df2\u5b89\u88c5\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u7cfb\u7edf\uff0c\u672c\u6b21\u4e3a\u65b0\u623f\u914d\u7f6e<\/td><\/tr>\n      <\/table>\n    <\/div>\n    <div class=\"info-card\">\n      <h4>\u6838\u5fc3\u76ee\u6807<\/h4>\n      <ul>\n        <li>\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff08\u5ba2\u9910\u538571\u578b\u5355\u53f0\u8986\u76d6\uff09<\/li>\n        <li>\u5730\u6696\u4e09\u79cd\u65b9\u6848\u5bf9\u6bd4\u51b3\u7b56<\/li>\n        <li>\u6539\u5584\u70ed\u6c34\u4f53\u9a8c\uff08\u6c34\u91cf\u5c0f\/\u5ffd\u51b7\u5ffd\u70ed\uff09<\/li>\n        <li>\u52a0\u88c5PE\u51c0\u5316\uff08\u5c0f\u5b69+\u5ba0\u7269\uff09<\/li>\n        <li>\u63a7\u5236\u521d\u6295\u4e0e\u957f\u671f\u4f7f\u7528\u8d39<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <div class=\"info-grid-2\">\n    <div class=\"info-card\">\n      <h4>\u51b3\u7b56\u98ce\u683c<\/h4>\n      <p><strong>\"\u65e2\u8981\u53c8\u8981\"\u578b\uff1a<\/strong>\u65e2\u8981\u7701\u94b1\uff08\u521d\u6295\u4f4e\uff09\uff0c\u53c8\u8981\u6548\u679c\u597d\uff1b\u65e2\u8981\u5730\u6696\u8212\u670d\uff0c\u53c8\u8981\u70ed\u6c34\u4e0d\u51b7\u3002<\/p>\n      <p style=\"margin-top:6px\">\u6574\u4f53\u503e\u5411\u7406\u6027\uff0c\u613f\u610f\u542c\u53d6\u4e13\u4e1a\u903b\u8f91\uff0c\u4ee5\u6570\u636e\u548c\u5386\u53f2\u6848\u4f8b\u8f85\u52a9\u51b3\u7b56\u3002<\/p>\n    <\/div>\n    <div class=\"info-card\">\n      <h4>\u6237\u578b\u4e0e\u914d\u7f6e<\/h4>\n      <table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n        <tr><th style=\"text-align:left;padding:3px 6px;font-size:13px;color:var(--text-light);font-weight:500\">\u5ba2\u9910\u5385<\/th><td style=\"padding:3px 6px\">42\u33a1 \u2192 71\u578b\u5355\u53f0<\/td><\/tr>\n        <tr><th style=\"text-align:left;padding:3px 6px;font-size:13px;color:var(--text-light);font-weight:500\">\u8001\u4eba\u623f<\/th><td style=\"padding:3px 6px\">13\u33a1 \u2192 22\u578b<\/td><\/tr>\n        <tr><th style=\"text-align:left;padding:3px 6px;font-size:13px;color:var(--text-light);font-weight:500\">\u513f\u7ae5\u623f<\/th><td style=\"padding:3px 6px\">13\u33a1 \u2192 22\u578b<\/td><\/tr>\n        <tr><th style=\"text-align:left;padding:3px 6px;font-size:13px;color:var(--text-light);font-weight:500\">\u4e3b\u5367<\/th><td style=\"padding:3px 6px\">24\u33a1 \u2192 36\u578b<\/td><\/tr>\n        <tr><th style=\"text-align:left;padding:3px 6px;font-size:13px;color:var(--text-light);font-weight:500\">\u4e66\u623f<\/th><td style=\"padding:3px 6px\">8.65\u33a1 \u2192 22\u578b<\/td><\/tr>\n        <tr><th style=\"text-align:left;padding:3px 6px;font-size:13px;color:var(--text-light);font-weight:500\">\u52a0\u88c5<\/th><td style=\"padding:3px 6px\">PE\u751f\u6001\u51c0\u5316\u6a21\u5757<\/td><\/tr>\n      <\/table>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- ==================== S2 \u9700\u6c42\u4e0e\u8bbe\u8ba1\u7b56\u7565 ==================== -->\n<div class=\"geo-step\">\n  <div class=\"geo-step-header\">\n    <span class=\"geo-step-num\">2<\/span>\n    <div><div class=\"geo-step-title\">S2 \u00b7 \u9700\u6c42\u4e0e\u8bbe\u8ba1\u7b56\u7565<\/div><div class=\"geo-step-sub\">\u8bbe\u8ba1\u903b\u8f91\u9a8c\u8bc1 \u00b7 \u65b9\u6848\u8def\u5f84\u68b3\u7406 \u00b7 \u8001\u5ba2\u6237\u6743\u76ca<\/div><\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u5ba2\u9910\u5385\u4e00\u53f071\u673a\u591f\u4e0d\u591f\uff1f<\/div>\n  <div class=\"summary-box\">\n    <p style=\"font-size:15px;font-weight:600;color:var(--green);margin-bottom:10px\">\u591f\u7528\u3002\u4e09\u4e2a\u7ef4\u5ea6\u9a8c\u8bc1\uff1a<\/p>\n    <ul>\n      <li><strong>\u56fd\u6807\uff1a<\/strong>\u9ad8\u5c42\u4f4f\u5b85\u5236\u51b7\u8d1f\u837780-120W\/\u33a1\uff0c42\u33a1\u00d7120W=5,040W\u9700\u6c42\uff0c71\u673a7.1kW\u5b8c\u5168\u8986\u76d6<\/li>\n      <li><strong>\u7528\u6237\u884c\u4e3a\uff1a<\/strong>\u590d\u76d8\u8001\u5ba2\u6237\uff0c\u5ba2\u9910\u5385\u914d\u4e24\u53f0\u5185\u673a\u65f690%\u4ee5\u4e0a\u5e38\u5e74\u53ea\u5f00\u4e00\u53f0<\/li>\n      <li><strong>\u5386\u53f2\u6570\u636e\uff1a<\/strong>\u91d1\u6c99\u57ce\u7b49\u5ba2\u623750+\u33a1\u5ba2\u9910\u5385\uff0c\u5355\u53f0\u5185\u673a\u7535\u8d39\u7ea6700\u5143\/\u6708\u6548\u679c\u8db3\u591f<\/li>\n    <\/ul>\n    <p style=\"margin-top:10px;font-size:14px;color:var(--text-light)\">\u8bbe\u8ba1\u903b\u8f91\uff1a\u65b9\u6b63\u6237\u578b\u4e00\u53f0\u5c45\u4e2d\u5e03\u7f6e\uff0c\u6c14\u6d41\u7ec4\u7ec7\u6700\u4f73<\/p>\n  <\/div>\n\n  <div class=\"section-title\">\u4e00\u62d6\u4e94 vs \u4e00\u62d6\u516d<\/div>\n  <div class=\"summary-box\">\n    <p style=\"font-size:14px\"><strong>\u63a8\u8350\u4e00\u62d6\u4e94<\/strong>\uff08\u5ba2\u53851\u53f0+\u5367\u5ba44\u53f0\uff09\uff0c\u4e0d\u63a8\u8350\u4e00\u62d6\u516d\uff08\u6ca1\u5fc5\u8981\u4e3a\u6781\u5c11\u5f00\u7684\u5c0f\u623f\u95f4\u5355\u72ec\u52a0\u4e00\u53f0\u5185\u673a\uff09\u3002<\/p>\n    <ul style=\"margin-top:8px\">\n      <li>\u5c11\u4e00\u53f0\u5185\u673a\uff1a\u8212\u4eab\u7cfb\u5217\u7701\u7ea64,000+\u5143 \/ \u5c0a\u777f\u7cfb\u5217\u7701\u7ea65,000-6,000\u5143<\/li>\n      <li>\u907f\u514d\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\uff1a\u5927\u4e3b\u673a\uff08\u5982180\uff09\u4f4e\u9891\u65f6\u80fd\u6548\u4e0b\u964d\uff0c\u9891\u7e41\u542f\u505c\u5f71\u54cd\u5bff\u547d\u548c\u8212\u9002\u5ea6<\/li>\n    <\/ul>\n  <\/div>\n\n  <div class=\"section-title\">\u5730\u6696\u4e09\u79cd\u65b9\u6848\u8def\u5f84<\/div>\n  <p style=\"font-size:14px;color:var(--text-light);margin-bottom:12px\">\u5ba2\u6237\u4e3b\u52a8\u63d0\u51fa\u4e09\u79cd\u65b9\u6848\uff0c\u987e\u95ee\u68b3\u7406\u5982\u4e0b\uff1a<\/p>\n\n  <div class=\"card-grid\">\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-b\">\u65b9\u6848\u4e00 \u00b7 \u9505\u7089\u4e24\u7528\u7089<\/div>\n      <div class=\"card-body\">\n        <table>\n          <tr><td>\u7cfb\u7edf<\/td><td>\u4e2d\u592e\u7a7a\u8c03+\u666e\u901a\u9505\u7089\u4e24\u7528\u7089\uff08\u5730\u6696+\u70ed\u6c34\u5171\u7528\uff09<\/td><\/tr>\n          <tr><td>\u521d\u6295<\/td><td>\u8f83\u4f4e<\/td><\/tr>\n          <tr><td>\u70ed\u6c34\u4f53\u9a8c<\/td><td>\u8f83\u5dee\uff08\u6c34\u91cf\u5c0f\u00b7\u5ffd\u51b7\u5ffd\u70ed\u00b7\u590f\u5b63\u4e5f\u8017\u6c14\uff09<\/td><\/tr>\n          <tr><td>\u5730\u6696\u6548\u7387<\/td><td>\u666e\u901a<\/td><\/tr>\n          <tr><td>20\u5e74\u603b\u8d39\u7528<\/td><td>\u4e2d\u7b49\u504f\u9ad8<\/td><\/tr>\n          <tr><td>\u9002\u5408<\/td><td>\u9884\u7b97\u4f18\u5148\u3001\u5bf9\u70ed\u6c34\u8981\u6c42\u4e0d\u9ad8\u7684\u5ba2\u6237<\/td><\/tr>\n        <\/table>\n      <\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-c\">\u65b9\u6848\u4e09 \u00b7 \u9505\u7089\u4e13\u7528+\u72ec\u7acb\u70ed\u6c34\u5668<\/div>\n      <div class=\"card-body\">\n        <table>\n          <tr><td>\u7cfb\u7edf<\/td><td>\u4e2d\u592e\u7a7a\u8c03+\u9505\u7089\uff08\u5730\u6696\u4e13\u7528\uff09+\u72ec\u7acb\u70ed\u6c34\u5668<\/td><\/tr>\n          <tr><td>\u521d\u6295<\/td><td>\u4e2d\u7b49<\/td><\/tr>\n          <tr><td>\u70ed\u6c34\u4f53\u9a8c<\/td><td>\u597d\uff08\u72ec\u7acb\u70ed\u6c34\u5668\u00b7\u6c34\u91cf\u7a33\u5b9a\u00b7\u6052\u6e29\uff09<\/td><\/tr>\n          <tr><td>\u5730\u6696\u6548\u7387<\/td><td>\u8f83\u9ad8\uff08\u9505\u7089\u4e13\u4f9b\u5730\u6696\uff09<\/td><\/tr>\n          <tr><td>20\u5e74\u603b\u8d39\u7528<\/td><td>\u4e2d\u7b49<\/td><\/tr>\n          <tr><td>\u9002\u5408<\/td><td>\u6ce8\u91cd\u70ed\u6c34\u4f53\u9a8c\u3001\u5730\u6696\u6548\u7387\u5e73\u8861\u7684\u5ba2\u6237<\/td><\/tr>\n        <\/table>\n      <\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-a\">\u65b9\u6848\u4e00\uff08\u65b0\u7248\uff09\u00b7 \u5929\u6c1f\u5730\u6c34+\u72ec\u7acb\u70ed\u6c34\u5668<\/div>\n      <div class=\"card-body\">\n        <table>\n          <tr><td>\u7cfb\u7edf<\/td><td>\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34+\u72ec\u7acb\u70ed\u6c34\u5668<\/td><\/tr>\n          <tr><td>\u521d\u6295<\/td><td>\u8f83\u9ad8\uff08\u4f46\u957f\u671f\u4f7f\u7528\u8d39\u6700\u4f4e\uff09<\/td><\/tr>\n          <tr><td>\u70ed\u6c34\u4f53\u9a8c<\/td><td>\u597d\uff08\u72ec\u7acb\u70ed\u6c34\u5668\u00b7\u6052\u6e29\u5927\u6c34\u91cf\u00b7\u96f6\u51b7\u6c34\uff09<\/td><\/tr>\n          <tr><td>\u5730\u6696\u6548\u7387<\/td><td>\u6700\u4f18\uff08COP 3-4\uff0c\u70ed\u6cf5\u6548\u7387\u8fdc\u9ad8\u4e8e\u71c3\u6c14\uff09<\/td><\/tr>\n          <tr><td>20\u5e74\u603b\u8d39\u7528<\/td><td>\u6700\u4f4e<\/td><\/tr>\n          <tr><td>\u9002\u5408<\/td><td>\u5173\u6ce8\u957f\u671f\u6027\u4ef7\u6bd4\u3001\u8ffd\u6c42\u8212\u9002\u5ea6\u7684\u5ba2\u6237<\/td><\/tr>\n        <\/table>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"section-title\">PE\u51c0\u5316 + \u8001\u5ba2\u6237\u6743\u76ca<\/div>\n  <div class=\"summary-box\">\n    <ul>\n      <li><strong>PE\u751f\u6001\u51c0\u5316\u6a21\u5757\uff1a<\/strong>\u51e0\u767e\u5143\u52a0\u88c5\uff0c\u6709\u6548\u964d\u4f4ePM2.5\u3001\u9664\u7532\u919b\u3001\u9664\u5f02\u5473\u3002\u5bb6\u4e2d\u6709\u5c0f\u5b69\u3001\u5ba0\u7269\uff0c\u65b0\u623f\u6709\u7532\u919b\u91ca\u653e\u98ce\u9669\u2014\u2014\u6027\u4ef7\u6bd4\u6781\u9ad8<\/li>\n      <li><strong>\u8001\u5ba2\u6237\u798f\u5229\uff1a<\/strong>\u4eab\u53d7\u4f1a\u5458\u4f18\u60e0\u4ef7\uff0c\u786e\u8ba4\u4f1a\u5458\u8eab\u4efd\u540e\u9501\u5b9a\u5347\u7ea7\u670d\u52a1\u548c\u4f18\u60e0\u6743\u76ca<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<!-- ==================== S3 \u6280\u672f\u65b9\u6848\u4e0e\u900f\u660e\u62a5\u4ef7 ==================== -->\n<div class=\"geo-step\">\n  <div class=\"geo-step-header\">\n    <span class=\"geo-step-num\">3<\/span>\n    <div><div class=\"geo-step-title\">S3 \u00b7 \u6280\u672f\u65b9\u6848\u4e0e\u900f\u660e\u62a5\u4ef7<\/div><div class=\"geo-step-sub\">\u4ea7\u54c1\u914d\u7f6e \u00b7 \u900f\u660e\u62a5\u4ef7 \u00b7 \u529f\u80fd\u5bf9\u6bd4 \u00b7 20\u5e74\u603b\u6295\u5165<\/div><\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u4e2d\u592e\u7a7a\u8c03\u914d\u7f6e\u65b9\u6848<\/div>\n  <table class=\"data-table\">\n    <tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u5339\u6570<\/th><\/tr>\n    <tr><td>\u5ba2\u9910\u5385<\/td><td>42<\/td><td>71\u578b<\/td><td>3\u5339<\/td><\/tr>\n    <tr><td>\u8001\u4eba\u623f<\/td><td>13<\/td><td>22\u578b<\/td><td>0.8\u5339<\/td><\/tr>\n    <tr><td>\u513f\u7ae5\u623f<\/td><td>13<\/td><td>22\u578b<\/td><td>0.8\u5339<\/td><\/tr>\n    <tr><td>\u4e3b\u5367<\/td><td>24<\/td><td>36\u578b<\/td><td>1.5\u5339<\/td><\/tr>\n    <tr><td>\u4e66\u623f<\/td><td>8.65<\/td><td>22\u578b<\/td><td>0.8\u5339<\/td><\/tr>\n    <tr style=\"background:#f0f4f8;font-weight:600\"><td>\u5408\u8ba1<\/td><td>~101<\/td><td>\u4e00\u62d6\u4e94<\/td><td>\u4e3b\u673a160\uff08\u8d85\u914d\u7387108%\uff09<\/td><\/tr>\n  <\/table>\n\n  <div class=\"section-title\">\u4e09\u5957\u65b9\u6848\u603b\u89c8<\/div>\n  <div class=\"card-grid\">\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-a\">\u65b9\u6848\u4e00 \u00b7 \u5c0a\u4eab\u65d7\u8230\u578b<br><span style=\"font-size:12px;opacity:0.85\">\u5929\u6c1f\u5730\u6c34 + \u72ec\u7acb\u70ed\u6c34\u5668<\/span><\/div>\n      <div class=\"card-body\">\n        <table>\n          <tr><td>\u7a7a\u8c03\u4e3b\u673a<\/td><td><a href=\"https:\/\/longmai-nt.com\/guide\/zunrui-quanxiao.html\" style=\"color:inherit;text-decoration:underline\">\u5c0a\u777f\u5168\u6548II 160<\/a>\uff08RAS-160FSXPN5Q\uff09<\/td><\/tr>\n          <tr><td>\u5ba4\u5185\u673a<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a \u00d7 5<\/td><\/tr>\n          <tr><td>\u6c34\u6a21\u5757<\/td><td>RWMG-160FWXNZQ<\/td><\/tr>\n          <tr><td>\u7ebf\u63a7\u5668<\/td><td>\u9ad8\u6e05\u5f69\u5c4f \u00d7 5<\/td><\/tr>\n          <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u4f1f\u661f\u963b\u6c27+\u8054\u52a8 179\u5143\/\u33a1<\/td><\/tr>\n          <tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td><a href=\"https:\/\/longmai-nt.com\/guide\/zunrui-quanxiao.html\" style=\"color:inherit;text-decoration:underline\">\u745e\u7f8e16L\u96f6\u51b7\u6c34\u72ec\u7acb\u70ed\u6c34\u5668<\/a><\/td><\/tr>\n          <tr><td>PE\u51c0\u5316<\/td><td>JK-LZA \u6a21\u5757<\/td><\/tr>\n        <\/table>\n      <\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-b\">\u65b9\u6848\u4e8c \u00b7 \u7ecf\u6d4e\u5165\u95e8\u578b<br><span style=\"font-size:12px;opacity:0.85\">\u6c1f\u7a7a\u8c03 + \u535a\u4e16\u4e24\u7528\u7089<\/span><\/div>\n      <div class=\"card-body\">\n        <table>\n          <tr><td>\u7a7a\u8c03\u4e3b\u673a<\/td><td><a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" style=\"color:inherit;text-decoration:underline\">\u8212\u4eab\u7cfb\u5217160<\/a>\uff08RAS-160HRNAQ\uff09<\/td><\/tr>\n          <tr><td>\u5ba4\u5185\u673a<\/td><td>DC\u6807\u51c6\u5185\u673a \u00d7 5<\/td><\/tr>\n          <tr><td>\u7ebf\u63a7\u5668<\/td><td>WiFi\u7ebf\u63a7\u5668 \u00d7 5<\/td><\/tr>\n          <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u4f1f\u661f\u767d\u6676+\u8054\u52a8 169\u5143\/\u33a1<\/td><\/tr>\n          <tr><td>\u5730\u6696\u70ed\u6e90 + \u70ed\u6c34<\/td><td>\u535a\u4e16G6100W 24kW\u4e24\u7528\u7089\uff0811.8L\/min\uff09<\/td><\/tr>\n          <tr><td>PE\u51c0\u5316<\/td><td>\u53ef\u9009\u914d<\/td><\/tr>\n        <\/table>\n      <\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-c\">\u65b9\u6848\u4e09 \u00b7 \u5206\u4f53\u4f18\u9009\u578b<br><span style=\"font-size:12px;opacity:0.85\">\u6c1f\u7a7a\u8c03 + \u53d8\u9891\u91c7\u6696 + \u72ec\u7acb\u70ed\u6c34<\/span><\/div>\n      <div class=\"card-body\">\n        <table>\n          <tr><td>\u7a7a\u8c03\u4e3b\u673a<\/td><td><a href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" style=\"color:inherit;text-decoration:underline\">\u8212\u4eab\u7cfb\u5217160<\/a>\uff08RAS-160HRNAQ\uff09<\/td><\/tr>\n          <tr><td>\u5ba4\u5185\u673a<\/td><td>DC\u6807\u51c6\u5185\u673a \u00d7 5<\/td><\/tr>\n          <tr><td>\u7ebf\u63a7\u5668<\/td><td>WiFi\u7ebf\u63a7\u5668 \u00d7 5<\/td><\/tr>\n          <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u4f1f\u661f\u767d\u6676+\u8054\u52a8 169\u5143\/\u33a1<\/td><\/tr>\n          <tr><td>\u5730\u6696\u70ed\u6e90<\/td><td>\u66fc\u745e\u5fb718kW\u53d8\u9891\u5355\u91c7\u6696\u7089<\/td><\/tr>\n          <tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u745e\u7f8e16L\u96f6\u51b7\u6c34\u72ec\u7acb\u70ed\u6c34\u5668<\/td><\/tr>\n          <tr><td>PE\u51c0\u5316<\/td><td>\u53ef\u9009\u914d<\/td><\/tr>\n        <\/table>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u900f\u660e\u62a5\u4ef7<\/div>\n\n  <div class=\"section-subtitle\">\u7a7a\u8c03\u8bbe\u5907\u62a5\u4ef7<\/div>\n  <table class=\"data-table\">\n    <tr><th>\u8d39\u7528\u9879\u76ee<\/th><th>\u65b9\u6848\u4e00\uff08\u5c0a\u777f\u65d7\u8230\uff09<\/th><th>\u65b9\u6848\u4e8c\uff08\u8212\u4eab\u7ecf\u6d4e\uff09<\/th><th>\u65b9\u6848\u4e09\uff08\u8212\u4eab\u5206\u4f53\uff09<\/th><\/tr>\n    <tr><td>\u4e3b\u673a\u9762\u4ef7<\/td><td>20,600\u5143<\/td><td>13,775\u5143<\/td><td>13,775\u5143<\/td><\/tr>\n    <tr><td>\u5185\u673a71\u578b\u9762\u4ef7<\/td><td>5,825\u5143\uff08\u4e09\u7ba1\u5236\u51c0\u5316\uff09<\/td><td>3,513\u5143\uff08DC\u6807\u51c6\uff09<\/td><td>3,513\u5143\uff08DC\u6807\u51c6\uff09<\/td><\/tr>\n    <tr><td>\u5185\u673a22\u578b\u00d73\u9762\u4ef7<\/td><td>15,150\u5143\uff08\u4e09\u7ba1\u5236\u51c0\u5316\uff09<\/td><td>9,039\u5143\uff08DC\u6807\u51c6\uff09<\/td><td>9,039\u5143\uff08DC\u6807\u51c6\uff09<\/td><\/tr>\n    <tr><td>\u5185\u673a36\u578b\u9762\u4ef7<\/td><td>5,238\u5143\uff08\u4e09\u7ba1\u5236\u51c0\u5316\uff09<\/td><td>3,125\u5143\uff08DC\u6807\u51c6\uff09<\/td><td>3,125\u5143\uff08DC\u6807\u51c6\uff09<\/td><\/tr>\n    <tr><td>\u6c34\u6a21\u5757\u9762\u4ef7<\/td><td>8,375\u5143<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u7ebf\u63a7\u5668\u00d75<\/td><td>2,380\u5143\uff08\u9ad8\u6e05\u5f69\u5c4f\uff09<\/td><td>1,000\u5143\uff08WiFi\uff09<\/td><td>1,000\u5143\uff08WiFi\uff09<\/td><\/tr>\n    <tr style=\"background:#f0f4f8\"><td><strong>\u8bbe\u5907\u9762\u4ef7\u5408\u8ba1<\/strong><\/td><td><strong>57,568\u5143<\/strong><\/td><td><strong>30,452\u5143<\/strong><\/td><td><strong>30,452\u5143<\/strong><\/td><\/tr>\n    <tr style=\"background:#fff8e1\"><td><strong>\u6298\u6263\u89c4\u5219<\/strong><\/td><td>\u5c0a\u777f\u8bbe\u59078\u6298\uff1b\u6c34\u6a21\u5757\u4e0d\u6253\u6298<\/td><td><strong>\u8212\u4eab\u7cfb\u52178.0\u6298<\/strong><\/td><td><strong>\u8212\u4eab\u7cfb\u52178.0\u6298<\/strong><\/td><\/tr>\n    <tr><td>\u6298\u540e\u2014\u4e3b\u673a\/\u5185\u673a\/\u7ebf\u63a7\u5668<\/td><td>49,193\u00d70.8=39,354\u5143<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u6298\u540e\u2014\u6c34\u6a21\u5757<\/td><td>8,375\u5143\uff08\u4e0d\u6253\u6298\uff09<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr>\n    <tr style=\"background:#f0f4f8\"><td><strong>\u6298\u540e\u8bbe\u5907\u4ef7<\/strong><\/td><td><strong>47,729\u5143<\/strong><\/td><td><strong>24,362\u5143<\/strong><\/td><td><strong>24,362\u5143<\/strong><\/td><\/tr>\n    <tr><td>\u4e3b\u673a\u5b89\u88c5\u8d39<\/td><td>\u5df2\u542b<\/td><td>\u5df2\u542b<\/td><td>\u5df2\u542b<\/td><\/tr>\n    <tr><td>\u5185\u673a\u5b89\u88c5\u8d39\u00d75<\/td><td>9,500\u5143<\/td><td>8,000\u5143<\/td><td>8,000\u5143<\/td><\/tr>\n    <tr><td>\u6c34\u6a21\u5757\u5b89\u88c5\u8d39<\/td><td>625\u5143<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr>\n    <tr style=\"background:#f0f4f8\"><td><strong>\u7a7a\u8c03\u603b\u4ef7<\/strong><\/td><td><strong>57,854\u5143<\/strong><\/td><td><strong>32,362\u5143<\/strong><\/td><td><strong>32,362\u5143<\/strong><\/td><\/tr>\n  <\/table>\n\n  <div class=\"section-subtitle\">\u5730\u6696\u7cfb\u7edf + \u70ed\u6e90\/\u70ed\u6c34\u62a5\u4ef7<\/div>\n  <table class=\"data-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u65b9\u6848\u4e00<\/th><th>\u65b9\u6848\u4e8c<\/th><th>\u65b9\u6848\u4e09<\/th><\/tr>\n    <tr><td>\u5730\u6696\u5957\u9910<\/td><td>\u4f1f\u661f\u963b\u6c27+\u8054\u52a8 179\u5143\/\u33a1<\/td><td>\u4f1f\u661f\u767d\u6676+\u8054\u52a8 169\u5143\/\u33a1<\/td><td>\u4f1f\u661f\u767d\u6676+\u8054\u52a8 169\u5143\/\u33a1<\/td><\/tr>\n    <tr><td>\u5730\u6696\u5c0f\u8ba1\uff08100\u33a1\uff09<\/td><td>17,900\u5143<\/td><td>16,900\u5143<\/td><td>16,900\u5143<\/td><\/tr>\n    <tr><td>\u9505\u7089\/\u70ed\u6e90<\/td><td>\u2014<\/td><td>\u535a\u4e16G6100W 24kW<\/td><td>\u66fc\u745e\u5fb7N1PB18 \u53d8\u9891\u5355\u91c7\u6696<\/td><\/tr>\n    <tr><td>\u9505\u7089\uff08\u542b\u5b89\u88c5\uff09<\/td><td>\u2014<\/td><td>6,450\u5143<\/td><td>5,266\u5143<\/td><\/tr>\n    <tr><td>\u70ed\u6c34\u5668<\/td><td>\u745e\u7f8e16L\u96f6\u51b7\u6c34 3,999\u5143<\/td><td>\u9505\u7089\u4e00\u4f53\uff08\u65e0\uff09<\/td><td>\u745e\u7f8e16L\u96f6\u51b7\u6c34 3,999\u5143<\/td><\/tr>\n  <\/table>\n\n  <div class=\"section-subtitle\">\u521d\u6295\u8d44\u6c47\u603b<\/div>\n  <div class=\"cost-summary\">\n    <div class=\"cost-card\"><div class=\"label\">\u65b9\u6848\u4e00 \u00b7 \u5c0a\u4eab\u65d7\u8230\u578b<\/div><div class=\"amount\" style=\"color:var(--blue)\">79,753\u5143<\/div><div class=\"label\">\u7a7a\u8c0357,854 + \u5730\u669617,900 + \u70ed\u6c343,999<\/div><\/div>\n    <div class=\"cost-card\"><div class=\"label\">\u65b9\u6848\u4e8c \u00b7 \u7ecf\u6d4e\u5165\u95e8\u578b<\/div><div class=\"amount\" style=\"color:var(--orange)\">55,712\u5143<\/div><div class=\"label\">\u7a7a\u8c0332,362 + \u5730\u669616,900 + \u9505\u70896,450<\/div><\/div>\n    <div class=\"cost-card\"><div class=\"label\">\u65b9\u6848\u4e09 \u00b7 \u5206\u4f53\u4f18\u9009\u578b<\/div><div class=\"amount\" style=\"color:var(--green)\">58,527\u5143<\/div><div class=\"label\">\u7a7a\u8c0332,362 + \u5730\u669616,900 + \u9505\u7089\u70ed\u6c349,265<\/div><\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u4ea7\u54c1\u529f\u80fd\u5bf9\u6bd4<\/div>\n  <table class=\"data-table comp-table\">\n    <tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00\uff08\u5c0a\u777f\u5168\u6548\uff09<\/th><th>\u65b9\u6848\u4e8c\uff08\u8212\u4eab+\u535a\u4e16\uff09<\/th><th>\u65b9\u6848\u4e09\uff08\u8212\u4eab+\u66fc\u745e\u5fb7\uff09<\/th><\/tr>\n    <tr><td>\u538b\u7f29\u673a<\/td><td>\u53cc\u8f6c\u5b50+\u8865\u6c14\u589e\u7113<\/td><td>\u53cc\u8f6c\u5b50<\/td><td>\u53cc\u8f6c\u5b50<\/td><\/tr>\n    <tr><td>\u6e29\u6e7f\u53cc\u63a7<\/td><td><span class=\"tag-best\">\u652f\u6301\uff08\u4e09\u7ba1\u5236\u72ec\u7acb\u9664\u6e7f\uff09<\/span><\/td><td>\u4e0d\u652f\u6301<\/td><td>\u4e0d\u652f\u6301<\/td><\/tr>\n    <tr><td>\u51c0\u5316\u529f\u80fd<\/td><td><span class=\"tag-best\">\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/span><\/td><td>\u65e0\u51c0\u5316<\/td><td>\u65e0\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u70ed\u6e90\u6548\u7387<\/td><td><span class=\"tag-best\">COP\u22483.5\uff08\u7535\u9a71\u70ed\u6cf5\uff09<\/span><\/td><td>\u7ea688%\uff08\u71c3\u6c14\uff09<\/td><td>\u7ea692%\uff08\u71c3\u6c14\uff09<\/td><\/tr>\n    <tr><td>\u70ed\u6c34\u4ea7\u7387<\/td><td><span class=\"tag-best\">16L\/min \u96f6\u51b7\u6c34<\/span><\/td><td>11.8L\/min \u5ffd\u51b7\u5ffd\u70ed<\/td><td><span class=\"tag-best\">16L\/min \u96f6\u51b7\u6c34<\/span><\/td><\/tr>\n    <tr><td>\u51ac\u5b63\u70ed\u6c34\u51b2\u7a81<\/td><td>\u65e0\u51b2\u7a81\uff08\u72ec\u7acb\u7cfb\u7edf\uff09<\/td><td><span class=\"tag-low\">\u5730\u6696\u62a2\u70ed\u6c34\u8d1f\u8377<\/span><\/td><td>\u65e0\u51b2\u7a81\uff08\u72ec\u7acb\u7cfb\u7edf\uff09<\/td><\/tr>\n    <tr><td>\u4e3b\u673a\u5bff\u547d<\/td><td><span class=\"tag-best\">20\u5e74+\uff0c\u65e0\u9700\u66f4\u6362<\/span><\/td><td>15~20\u5e74<\/td><td>15~20\u5e74<\/td><\/tr>\n    <tr><td>\u9505\u7089\u5bff\u547d<\/td><td>\u2014<\/td><td><span class=\"tag-low\">7~8\u5e74\uff08\u56fd\u6807\u5f3a\u5236\u6362\uff09<\/span><\/td><td><span class=\"tag-low\">7~8\u5e74\uff08\u56fd\u6807\u5f3a\u5236\u6362\uff09<\/span><\/td><\/tr>\n  <\/table>\n\n  <div class=\"section-title\">\u7cfb\u7edf\u4f18\u52a3\u5206\u6790<\/div>\n  <div class=\"card-grid\">\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-a\">\u65b9\u6848\u4e00 \u4f18\u52bf<\/div>\n      <div class=\"card-body\"><ul style=\"padding-left:18px;font-size:14px;line-height:2\">\n        <li>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff1a\u6885\u96e8\u5b63\u4e0d\u95f7\u4e0d\u6f6e<\/li>\n        <li>\u5929\u6c1f\u5730\u6c34\u8fd0\u884c\u8d39\u4ec5\u4e3a\u71c3\u6c14\u7089\u76841\/3~1\/2<\/li>\n        <li>\u5185\u673a\u81ea\u5e26\u51c0\u5316\uff0c\u5c0f\u5b69\u5ba0\u7269\u53cb\u597d<\/li>\n        <li>\u70ed\u6c34\u96f6\u51b7\u6c34+\u5927\u6d41\u91cf+\u4e0d\u53d7\u5e72\u6270<\/li>\n        <li><strong>\u4e3b\u673a\/\u6c34\u6a21\u575720\u5e74+\u514d\u66f4\u6362<\/strong><\/li>\n      <\/ul><\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header\" style=\"background:var(--blue)\">\u65b9\u6848\u4e00 \u52a3\u52bf<\/div>\n      <div class=\"card-body\"><ul style=\"padding-left:18px;font-size:14px;line-height:2;color:#c0392b\">\n        <li>\u521d\u6295\u6700\u9ad8\uff0879,753\u5143\uff09<\/li>\n        <li>\u4e09\u7ba1\u5236\u5185\u673a\u540a\u9876\u9700\u6c42\u7565\u5927<\/li>\n        <li>\u6c34\u6a21\u5757\u9700\u4e13\u4e1a\u8c03\u8bd5<\/li>\n      <\/ul><\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-b\">\u65b9\u6848\u4e8c \u4f18\u52bf<\/div>\n      <div class=\"card-body\"><ul style=\"padding-left:18px;font-size:14px;line-height:2\">\n        <li>\u521d\u6295\u6700\u4f4e\uff0855,712\u5143\uff09<\/li>\n        <li>\u7cfb\u7edf\u7b80\u5355\uff0c\u5b89\u88c5\u6210\u719f<\/li>\n        <li>\u4e00\u5957\u8bbe\u5907\u5360\u5730\u5c0f<\/li>\n      <\/ul><\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header\" style=\"background:var(--orange)\">\u65b9\u6848\u4e8c \u52a3\u52bf<\/div>\n      <div class=\"card-body\"><ul style=\"padding-left:18px;font-size:14px;line-height:2;color:#c0392b\">\n        <li>\u70ed\u6c34\u4f53\u9a8c\u5dee\uff0811.8L\u504f\u5c0f\u00b7\u5ffd\u51b7\u5ffd\u70ed\uff09<\/li>\n        <li>\u9505\u7089\u6548\u738788%\u8fd0\u884c\u8d39\u9ad8<\/li>\n        <li><strong>\u9505\u70897~8\u5e74\u6362\u00d72\u6b21=12,900\u5143<\/strong><\/li>\n        <li>\u51ac\u5b63\u5730\u6696\u62a2\u70ed\u6c34\u8d1f\u8377<\/li>\n      <\/ul><\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header plan-color-c\">\u65b9\u6848\u4e09 \u4f18\u52bf<\/div>\n      <div class=\"card-body\"><ul style=\"padding-left:18px;font-size:14px;line-height:2\">\n        <li>\u521d\u6295\u9002\u4e2d\uff0858,527\u5143\uff09<\/li>\n        <li>\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u4e92\u4e0d\u5e72\u6270<\/li>\n        <li>\u53d8\u9891\u7089\u7cbe\u51c6\u5339\u914d\u5730\u6696\u4f4e\u8d1f\u8377<\/li>\n        <li>\u70ed\u6c34\u4f53\u9a8c\u597d\u00b716L\u96f6\u51b7\u6c34<\/li>\n      <\/ul><\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header\" style=\"background:var(--green)\">\u65b9\u6848\u4e09 \u52a3\u52bf<\/div>\n      <div class=\"card-body\"><ul style=\"padding-left:18px;font-size:14px;line-height:2;color:#c0392b\">\n        <li>\u9505\u7089+\u70ed\u6c34\u5668\u5360\u7a7a\u95f4\u8f83\u5927<\/li>\n        <li><strong>\u9505\u70897~8\u5e74\u6362\u00d72\u6b21=10,532\u5143<\/strong><\/li>\n        <li>\u7a7a\u8c03\u4e0d\u53c2\u4e0e\u5236\u70ed<\/li>\n      <\/ul><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u8282\u80fd\u4e0e\u8fd0\u884c\u8d39\u5bf9\u6bd4<\/div>\n  <p style=\"font-size:13px;color:var(--text-light);margin-bottom:12px\">\u6d4b\u7b97\u57fa\u7840\uff1a\u6210\u90fd\u5730\u533a\uff0c\u91c7\u6696\u5b6390\u5929\uff0c100\u33a1\u5730\u6696\u6052\u6e29\u8d1f\u83776kW\uff0860W\/\u33a1\uff09\uff0c\u65e5\u8fd0\u884c10\u5c0f\u65f6\uff0c\u5929\u7136\u6c143.0\u5143\/m\u00b3\uff0c\u75350.6\u5143\/kWh<\/p>\n  <table class=\"data-table\">\n    <tr><th>\u5bf9\u6bd4\u9879\u76ee<\/th><th>\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/th><th>\u65b9\u6848\u4e8c\uff08\u535a\u4e16\u4e24\u7528\u7089\uff09<\/th><th>\u65b9\u6848\u4e09\uff08\u66fc\u745e\u5fb7\u53d8\u9891\uff09<\/th><\/tr>\n    <tr><td>\u70ed\u6e90\u6548\u7387<\/td><td>COP\u22483.5<\/td><td>88%<\/td><td>92%<\/td><\/tr>\n    <tr><td>\u5e74\u91c7\u6696\u8d39\u7528<\/td><td><span class=\"tag-best\">926\u5143<\/span><\/td><td>1,938\u5143<\/td><td>1,854\u5143<\/td><\/tr>\n    <tr><td>\u5e74\u70ed\u6c34\u8d39\u7528<\/td><td>300\u5143<\/td><td>500\u5143<\/td><td>300\u5143<\/td><\/tr>\n    <tr><td>\u5e74\u5236\u51b7\u7535\u8d39<\/td><td>~800\u5143<\/td><td>~800\u5143<\/td><td>~800\u5143<\/td><\/tr>\n    <tr style=\"background:#f0f4f8\"><td><strong>\u5e74\u8fd0\u884c\u603b\u8d39\u7528<\/strong><\/td><td><strong>~2,026\u5143<\/strong><\/td><td><strong>~3,238\u5143<\/strong><\/td><td><strong>~2,954\u5143<\/strong><\/td><\/tr>\n    <tr><td>vs \u65b9\u6848\u4e8c\u6bcf\u5e74\u8282\u7701<\/td><td><span class=\"tag-best\">1,212\u5143<\/span><\/td><td>\u2014<\/td><td>284\u5143<\/td><\/tr>\n  <\/table>\n\n  <div class=\"section-title\">20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\uff08\u542b\u8bbe\u5907\u66f4\u65b0\uff09<\/div>\n  <div class=\"summary-box\" style=\"border-left:4px solid var(--accent);background:#fff5f5\">\n    <h3 style=\"color:var(--accent);font-size:15px\">\u5bff\u547d\u5047\u8bbe\uff08\u672c\u62a5\u544a\u6838\u5fc3\u5dee\u5f02\uff09<\/h3>\n    <ul>\n      <li><strong>\u65b9\u6848\u4e00\uff1a<\/strong>\u5c0a\u777f\u5168\u6548\u4e3b\u673a+\u6c34\u6a21\u5757\u5bff\u547d20\u5e74+\uff0c20\u5e74\u5185\u65e0\u9700\u4e8c\u6b21\u8d2d\u7f6e\uff1b\u70ed\u6c34\u5668\u4e0d\u8003\u8651\u4e8c\u6b21\u8d2d\u7f6e\u8d39\u7528<\/li>\n      <li><strong>\u65b9\u6848\u4e8c\/\u4e09\uff1a<\/strong>\u71c3\u6c14\u9505\u7089\u6309\u56fd\u68077~8\u5e74\u66f4\u6362\uff0c20\u5e74\u5185\u63622\u6b21\uff08\u7b2c8\u5e74\u3001\u7b2c16\u5e74\uff09<\/li>\n    <\/ul>\n  <\/div>\n  <table class=\"data-table\">\n    <tr><th>\u8d39\u7528\u9879<\/th><th>\u65b9\u6848\u4e00<\/th><th>\u65b9\u6848\u4e8c<\/th><th>\u65b9\u6848\u4e09<\/th><\/tr>\n    <tr><td>\u521d\u6295\u8d44<\/td><td>79,753\u5143<\/td><td>55,712\u5143<\/td><td>58,527\u5143<\/td><\/tr>\n    <tr><td>20\u5e74\u8fd0\u884c\u8d39<\/td><td>40,520\u5143<\/td><td>64,760\u5143<\/td><td>59,080\u5143<\/td><\/tr>\n    <tr><td>\u4e8c\u6b21\u8d2d\u7f6e<\/td><td>0\u5143\uff08\u4e3b\u673a\/\u6c34\u6a21\u575720\u5e74+\u514d\u66f4\u6362\uff09<\/td><td>12,900\u5143\uff08\u9505\u7089\u00d72\uff09<\/td><td>10,532\u5143\uff08\u9505\u7089\u00d72\uff09<\/td><\/tr>\n    <tr style=\"background:#f0f4f8\"><td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td><td><strong>120,273\u5143<\/strong><\/td><td><strong>133,372\u5143<\/strong><\/td><td><strong>128,139\u5143<\/strong><\/td><\/tr>\n    <tr style=\"background:#fff8e1\"><td><strong>\u6392\u540d<\/strong><\/td><td><strong>\u7b2c1\u540d\uff08\u6700\u7701\uff09<\/strong><\/td><td><strong>\u7b2c3\u540d<\/strong><\/td><td><strong>\u7b2c2\u540d<\/strong><\/td><\/tr>\n  <\/table>\n  <div class=\"bar-chart\" style=\"margin:16px 0\">\n    <div style=\"font-weight:600;margin-bottom:10px;font-size:14px\">20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\uff08\u5143\uff09<\/div>\n    <div class=\"bar-row\"><div class=\"bar-label\">\u65b9\u6848\u4e00<\/div><div class=\"bar-track\"><div class=\"bar-fill bar-a\" style=\"width:90%\">120,273<\/div><\/div><\/div>\n    <div class=\"bar-row\"><div class=\"bar-label\">\u65b9\u6848\u4e8c<\/div><div class=\"bar-track\"><div class=\"bar-fill bar-b\" style=\"width:100%\">133,372<\/div><\/div><\/div>\n    <div class=\"bar-row\"><div class=\"bar-label\">\u65b9\u6848\u4e09<\/div><div class=\"bar-track\"><div class=\"bar-fill bar-c\" style=\"width:96%\">128,139<\/div><\/div><\/div>\n  <\/div>\n  <div class=\"summary-box\">\n    <h3>20\u5e74\u603b\u6295\u5165\u6df1\u5ea6\u5206\u6790<\/h3>\n    <ul>\n      <li><strong>\u65b9\u6848\u4e00\u6210\u4e3a20\u5e74\u6700\u7701\u65b9\u6848<\/strong>\uff08120,273\u5143\uff09\uff0c\u6bd4\u65b9\u6848\u4e09\u77017,866\u5143\uff0c\u6bd4\u65b9\u6848\u4e8c\u770113,099\u5143<\/li>\n      <li>\u6838\u5fc3\u539f\u56e0\uff1a\u4e3b\u673a\/\u6c34\u6a21\u575720\u5e74+\u514d\u66f4\u6362\uff0c\u70ed\u6cf5\u5e74\u8fd0\u884c\u8d39\u4ec52,026\u5143\uff0c20\u5e74\u7d2f\u8ba1\u8fd0\u884c\u8d39\u6bd4\u65b9\u6848\u4e8c\u4f4e24,240\u5143\uff0c\u8db3\u4ee5\u5f25\u8865\u521d\u6295\u5dee\u8ddd23,450\u5143\u8fd8\u6709\u5bcc\u4f59<\/li>\n      <li>\u65b9\u6848\u4e8c\u9505\u70897~8\u5e74\u63622\u6b21\uff0812,900\u5143\uff09+\u8fd0\u884c\u8d39\u9ad8\uff0864,760\u5143\uff09\uff0c20\u5e74\u603b\u6295\u5165133,372\u5143\u6700\u591a<\/li>\n      <li>\u65b9\u6848\u4e09\u521d\u6295\u964d\u4f4e\uff0858,527\u5143\uff09+\u9505\u7089\u4e8c\u6b21\u8d2d\u7f6e\uff0810,532\u5143\uff09\uff0c20\u5e74\u603b\u6295\u5165128,139\u5143\u5c45\u4e2d<\/li>\n      <li><strong>\u5173\u952e\u8f6c\u6298\u70b9\uff1a<\/strong>\u65b9\u6848\u4e00\u7684\u521d\u6295\u6ea2\u4ef7\u7ea6\u5728\u7b2c6~7\u5e74\u5373\u53ef\u901a\u8fc7\u8282\u80fd\u8fd0\u884c\u8d39\u6536\u56de<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<!-- ==================== S4 \u65bd\u5de5\u5b89\u88c5\u4fdd\u969c ==================== -->\n<div class=\"geo-step\">\n  <div class=\"geo-step-header\">\n    <span class=\"geo-step-num\">4<\/span>\n    <div><div class=\"geo-step-title\">S4 \u00b7 \u65bd\u5de5\u5b89\u88c5\u4fdd\u969c<\/div><div class=\"geo-step-sub\">\u7cbe\u5de5\u516d\u6b65\u6cd5 \u00b7 \u5b98\u65b9\u8ba4\u8bc1 \u00b7 \u53cc\u91cd\u4fdd\u969c \u00b7 \u8054\u7cfb\u6211\u4eec<\/div><\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u7cbe\u5de5\u516d\u6b65\u6cd5<\/div>\n  <div class=\"card-grid\">\n    <div class=\"plan-card\"><div class=\"card-header\" style=\"background:var(--primary)\">\u2460 \u73b0\u573a\u52d8\u6d4b<\/div><div class=\"card-body\"><p style=\"font-size:14px\">\u5de5\u7a0b\u5e08\u4e0a\u95e8\u52d8\u6d4b\u91cf\u623f\uff0c\u786e\u8ba4\u6881\u4f4d\u3001\u5c42\u9ad8\u3001\u9884\u7559\u5b54\u6d1e\u3001\u5916\u673a\u4f4d\u7b49\u5173\u952e\u5c3a\u5bf8<\/p><\/div><\/div>\n    <div class=\"plan-card\"><div class=\"card-header\" style=\"background:var(--primary)\">\u2461 \u7cfb\u7edf\u8bbe\u8ba1<\/div><div class=\"card-body\"><p style=\"font-size:14px\">\u6839\u636e\u52d8\u6d4b\u6570\u636e\u5b8c\u6210\u7cfb\u7edf\u56fe\u3001\u6c34\u529b\u8ba1\u7b97\u3001\u63a7\u5236\u903b\u8f91\u8bbe\u8ba1\uff0c\u8f93\u51fa\u65bd\u5de5\u56fe\u7eb8<\/p><\/div><\/div>\n    <div class=\"plan-card\"><div class=\"card-header\" style=\"background:var(--primary)\">\u2462 \u6750\u6599\u9a8c\u6536<\/div><div class=\"card-body\"><p style=\"font-size:14px\">\u4e1a\u4e3b\u5230\u573a\u6838\u5bf9\u54c1\u724c\u578b\u53f7\uff0c\u62cd\u7167\u7559\u6863\uff0c\u786e\u8ba4\u65b9\u53ef\u65bd\u5de5<\/p><\/div><\/div>\n    <div class=\"plan-card\"><div class=\"card-header\" style=\"background:var(--primary)\">\u2463 \u5145\u6c2e\u710a\u63a5\u5b89\u88c5<\/div><div class=\"card-body\"><p style=\"font-size:14px\">\u5168\u7a0b\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5\uff0c\u6bcf\u9053\u5de5\u5e8f\u62cd\u7167\u8bb0\u5f55\uff0c\u53ef\u8ffd\u6eaf<\/p><\/div><\/div>\n    <div class=\"plan-card\"><div class=\"card-header\" style=\"background:var(--primary)\">\u2464 \u62bd\u771f\u7a7a\u8c03\u8bd5<\/div><div class=\"card-body\"><p style=\"font-size:14px\">\u7cfb\u7edf\u62bd\u771f\u7a7a\u68c0\u6f0f\uff0c\u4fdd\u538b\u6d4b\u8bd5\uff0c\u8bbe\u5907\u8054\u52a8\u8c03\u8bd5<\/p><\/div><\/div>\n    <div class=\"plan-card\"><div class=\"card-header\" style=\"background:var(--primary)\">\u2465 \u7ae3\u5de5\u9a8c\u6536<\/div><div class=\"card-body\"><p style=\"font-size:14px\">\u63d0\u4ea4\u9879\u76ee\u6863\u6848\u4e66\uff08\u542b\u65bd\u5de5\u5168\u6d41\u7a0b\u7167\u7247\u3001\u8c03\u8bd5\u6570\u636e\u3001\u80fd\u8017\u57fa\u51c6\uff09<\/p><\/div><\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u5b98\u65b9\u6388\u6743\u8ba4\u8bc1<\/div>\n  <div class=\"summary-box\" style=\"text-align:center\">\n    <p style=\"font-size:15px;margin-bottom:8px\">\n      <span class=\"diamond-badge\">\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1<\/span>\n      &nbsp;&nbsp;\n      <span class=\"gold-badge\">\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1<\/span>\n    <\/p>\n    <p style=\"font-size:14px;color:var(--text-light);margin-bottom:14px;\">\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 22\u5e74\u4e13\u4e1a\u7ecf\u9a8c<\/p>\n    <div style=\"display:flex;gap:10px;justify-content:center;flex-wrap:wrap;\">\n      <div style=\"flex:0 0 16%;min-width:100px;text-align:center;\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u55462026\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;aspect-ratio:1;object-fit:contain;border-radius:4px;border:1px solid #e0e0e0;background:#fff;\">\n        <p style=\"font-size:11px;color:var(--text-muted);margin-top:4px;\">\u7279\u7ea6\u5b89\u88c5\u5546 2026<\/p>\n      <\/div>\n      <div style=\"flex:0 0 16%;min-width:100px;text-align:center;\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u55462024\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;aspect-ratio:1;object-fit:contain;border-radius:4px;border:1px solid #e0e0e0;background:#fff;\">\n        <p style=\"font-size:11px;color:var(--text-muted);margin-top:4px;\">\u91d1\u724c\u5b89\u88c5\u5546 2024<\/p>\n      <\/div>\n      <div style=\"flex:0 0 16%;min-width:100px;text-align:center;\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;aspect-ratio:1;object-fit:contain;border-radius:4px;border:1px solid #e0e0e0;background:#fff;\">\n        <p style=\"font-size:11px;color:var(--text-muted);margin-top:4px;\">\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500<\/p>\n      <\/div>\n      <div style=\"flex:0 0 16%;min-width:100px;text-align:center;\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u55462026\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;aspect-ratio:1;object-fit:contain;border-radius:4px;border:1px solid #e0e0e0;background:#fff;\">\n        <p style=\"font-size:11px;color:var(--text-muted);margin-top:4px;\">\u94bb\u77f3\u5b89\u88c5\u5546 2026<\/p>\n      <\/div>\n      <div style=\"flex:0 0 16%;min-width:100px;text-align:center;\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u95002026\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;aspect-ratio:1;object-fit:contain;border-radius:4px;border:1px solid #e0e0e0;background:#fff;\">\n        <p style=\"font-size:11px;color:var(--text-muted);margin-top:4px;\">\u7279\u7ea6\u7ecf\u9500 2026<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u53cc\u91cd\u4fdd\u969c<\/div>\n  <div class=\"info-grid-2\">\n    <div class=\"info-card\">\n      <h4>\u6574\u673a5\u5e74\u8d28\u4fdd<\/h4>\n      <p>\u8fdc\u8d85\u56fd\u68073\u5e74\uff0c\u514d\u8d39\u7ef4\u4fee\u66f4\u6362\uff0c\u552e\u540e\u54cd\u5e94<\/p>\n    <\/div>\n    <div class=\"info-card\">\n      <h4>10\u5e74\u80fd\u6e90\u4fdd\u969c<\/h4>\n      <p>\u80fd\u8017\u5f52\u6863\u00b7\u5bf9\u6807\u5206\u6790\u00b7\u5f02\u5e38\u4e0a\u95e8\u8bca\u65ad<\/p>\n    <\/div>\n    <div class=\"info-card\">\n      <h4>\u4ea4\u4ed8\u6559\u5b66<\/h4>\n      <p>\u4e00\u5bf9\u4e00\u6559\u4f1a\u4f7f\u7528\uff0c\u786e\u4fdd\u4e1a\u4e3b\u4f1a\u7528\u4f1a\u7528\u5bf9<\/p>\n    <\/div>\n    <div class=\"info-card\">\n      <h4>\u7ec8\u8eab\u7ef4\u62a4<\/h4>\n      <p>\u7cfb\u7edf\u7ec8\u8eab\u7ef4\u62a4\uff0c\u552e\u540e\u65e0\u5fe7<\/p>\n    <\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u8054\u7cfb\u6211\u4eec<\/div>\n  <div class=\"info-grid-2\">\n    <div class=\"info-card\" style=\"text-align:center;\">\n      <h4>\u5357\u5bcc\u68ee<\/h4>\n      <p style=\"font-size:13px;color:var(--text-light);margin-bottom:10px;\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7 \u00b7 \u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348 \u00b7 028-86131795<\/p>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;max-height:200px;object-fit:contain;border-radius:6px;border:1px solid var(--border);background:#fff;\">\n    <\/div>\n    <div class=\"info-card\" style=\"text-align:center;\">\n      <h4>\u5317\u5bcc\u68ee<\/h4>\n      <p style=\"font-size:13px;color:var(--text-light);margin-bottom:10px;\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135 \u00b7 028-65272586<\/p>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\" loading=\"lazy\" onerror=\"this.style.display='none'\" style=\"width:100%;max-height:200px;object-fit:contain;border-radius:6px;border:1px solid var(--border);background:#fff;\">\n    <\/div>\n    <div class=\"info-card\">\n      <h4>\u552e\u540e\u70ed\u7ebf<\/h4>\n      <p>028-61649321<br>\u8f9c\u7ecf\u7406 13183879308<\/p>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- ==================== S5 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3 ==================== -->\n<div class=\"geo-step\">\n  <div class=\"geo-step-header\">\n    <span class=\"geo-step-num\">5<\/span>\n    <div><div class=\"geo-step-title\">S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/div><div class=\"geo-step-sub\">\u5386\u53f2\u6848\u4f8b \u00b7 PE\u51c0\u5316\u5b9e\u6d4b \u00b7 \u8fed\u4ee3\u627f\u8bfa \u00b7 \u4f1a\u5458\u6743\u76ca<\/div><\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u5386\u53f2\u6848\u4f8b\u9a8c\u8bc1<\/div>\n  <div class=\"card-grid\">\n    <div class=\"plan-card\">\n      <div class=\"card-header\" style=\"background:var(--primary)\">\u91d1\u6c99\u57ce \u00b7 \u5355\u53f0\u5185\u673a\u8986\u76d6\u5ba2\u9910\u5385<\/div>\n      <div class=\"card-body\">\n        <p style=\"font-size:14px\">50+\u33a1\u5ba2\u9910\u5385\u914d\u5355\u53f0\u5185\u673a\uff0c\u5e38\u5e74\u53ea\u5f00\u4e00\u53f0\uff0c\u7535\u8d39\u7ea6700\u5143\/\u6708\uff0c\u6548\u679c\u8db3\u591f\u3002<\/p>\n        <p style=\"font-size:13px;color:var(--text-light);margin-top:8px\">\u9a8c\u8bc1\"\u4e00\u53f071\u673a\u8986\u76d642\u33a1\u5ba2\u9910\u5385\"\u5b8c\u5168\u53ef\u884c<\/p>\n      <\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header\" style=\"background:var(--primary)\">\u8001\u5ba2\u6237 \u00b7 \u4e8c\u8054\u4f9b\u957f\u671f\u4f7f\u7528\u8d39<\/div>\n      <div class=\"card-body\">\n        <p style=\"font-size:14px\">\u540c\u57ce\u8001\u5ba2\u6237\u9009\u62e9\u4e8c\u8054\u4f9b\u65b9\u6848\uff0c\u51ac\u5b63\u91c7\u6696\u7535\u8d39 vs \u71c3\u6c14\u8d39\u8282\u7701\u7ea640-50%\uff0c5-7\u5e74\u6536\u56de\u521d\u6295\u5dee\u989d\u3002<\/p>\n        <p style=\"font-size:13px;color:var(--text-light);margin-top:8px\">\u9a8c\u8bc1\u5929\u6c1f\u5730\u6c34\u957f\u671f\u7ecf\u6d4e\u6027<\/p>\n      <\/div>\n    <\/div>\n    <div class=\"plan-card\">\n      <div class=\"card-header\" style=\"background:var(--primary)\">PE\u51c0\u5316 \u00b7 \u5ba0\u7269\u5bb6\u5ead\u5b9e\u6d4b<\/div>\n      <div class=\"card-body\">\n        <p style=\"font-size:14px\">\u591a\u6237\u6709\u5c0f\u5b69\/\u5ba0\u7269\u5bb6\u5ead\u52a0\u88c5PE\u51c0\u5316\u6a21\u5757\u540e\uff0cPM2.5\u53bb\u966494.46%\uff0c\u7532\u919b\u53bb\u966474.9%\uff0c\u5f02\u5473\u660e\u663e\u6539\u5584\u3002<\/p>\n        <p style=\"font-size:13px;color:var(--text-light);margin-top:8px\">\u9a8c\u8bc1PE\u51c0\u5316\u5bf9\u5c0f\u5b69\u5ba0\u7269\u5bb6\u5ead\u7684\u5fc5\u8981\u6027<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"section-title\">\u8001\u5ba2\u6237\u4f1a\u5458\u6743\u76ca + \u8fed\u4ee3\u627f\u8bfa<\/div>\n  <div class=\"summary-box\">\n    <ul>\n      <li><strong>\u8001\u5ba2\u6237\u4f1a\u5458\u4e13\u5c5e\uff1a<\/strong>\u786e\u8ba4\u4f1a\u5458\u8eab\u4efd\u540e\u9501\u5b9a\u5347\u7ea7\u670d\u52a1\u548c\u4f18\u60e0\u6743\u76ca<\/li>\n      <li><strong>\u8fed\u4ee3\u627f\u8bfa\uff1a<\/strong>\u4ea4\u4ed8\u540e\u8ddf\u8e2a\u80fd\u8017\u6570\u636e\uff0c\u5e74\u5ea6\u56de\u8bbf\uff0c\u7cfb\u7edf\u4f18\u5316\u4e3b\u52a8\u63a8\u9001<\/li>\n      <li><strong>10\u5e74\u4fdd\u969c\uff1a<\/strong>\u5f02\u5e38\u80fd\u8017\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\uff0c\u786e\u4fdd\u957f\u671f\u4f7f\u7528\u6548\u679c<\/li>\n    <\/ul>\n  <\/div>\n\n  <div class=\"recommend-box\">\n    <h3>\u987e\u95ee\u63a8\u8350\uff1a\u65b9\u6848\u4e00 \u00b7 \u5c0a\u4eab\u65d7\u8230\u578b\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/h3>\n    <p>\u6839\u636e\u9648\u5148\u751f\"5\u4eba\u5e38\u4f4f\u3001\u957f\u8f88\u540c\u4f4f\u3001\u5c0f\u5b69+\u5ba0\u7269\"\u7684\u5bb6\u5ead\u7279\u5f81\uff1a<\/p>\n    <ul>\n      <li><strong>\u9996\u9009\uff1a\u65b9\u6848\u4e00\uff08\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\uff09<\/strong>\u3002\u521d\u629579,753\u5143\u867d\u6700\u9ad8\uff0c\u4f4620\u5e74\u603b\u6295\u5165120,273\u5143\u53cd\u800c\u662f\u4e09\u65b9\u6848\u4e2d\u6700\u7701\u7684\u3002\u4e3b\u673a\/\u6c34\u6a21\u575720\u5e74+\u514d\u66f4\u6362\uff0c\u5e74\u8fd0\u884c\u8d39\u4ec52,026\u5143\uff0c\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a\u5bf9\u5c0f\u5b69\u548c\u5ba0\u7269\u5bb6\u5ead\u53cb\u597d<\/li>\n      <li><strong>\u6b21\u9009\uff1a\u65b9\u6848\u4e09\uff08\u5206\u4f53\u4f18\u9009\u578b\uff09<\/strong>\u3002\u521d\u629558,527\u5143\uff0c20\u5e74\u603b\u6295\u5165128,139\u5143\uff0c\u70ed\u6c34\u4f53\u9a8c\u540c\u6837\u4f18\u79c0\uff0c\u4f46\u9700\u63a5\u53d7\u9505\u70897~8\u5e74\u66f4\u6362\u7684\u540e\u7eed\u6210\u672c<\/li>\n      <li><strong>\u4e0d\u63a8\u8350\u65b9\u6848\u4e8c\u3002<\/strong>\u4e24\u7528\u7089\u70ed\u6c34\u4f53\u9a8c\u5dee\uff0c20\u5e74\u603b\u6295\u5165133,372\u5143\u6700\u9ad8<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<!-- \u4ef7\u683c\u6765\u6e90 -->\n<div class=\"section\" style=\"margin:20px 0\">\n  <div class=\"section-title\">\u4ef7\u683c\u8bf4\u660e<\/div>\n  <table class=\"data-table\">\n    <tr><th style=\"width:180px\">\u4ef7\u683c\u6765\u6e90<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u9762\u4ef7\uff0c\u6765\u81ea\u4ef7\u683c\u6307\u4ee4\u5e93V5.0\uff08page_id=662\uff09<\/td><\/tr>\n    <tr><td>\u5c0a\u777f\u5168\u6548\u6298\u6263<\/td><td>\u8bbe\u5907\uff08\u4e3b\u673a+\u5185\u673a+\u7ebf\u63a7\u5668\uff098\u6298\uff1b\u6c34\u6a21\u5757\u4e0d\u6253\u6298<\/td><\/tr>\n    <tr><td>\u8212\u4eab\u7cfb\u5217\u6298\u6263<\/td><td>8.0\u6298\uff08\u6307\u4ee40\u53c2\u8003\u6298\u6263\uff09<\/td><\/tr>\n    <tr><td>\u5730\u6696\u5957\u9910<\/td><td>\u5957\u9910\u4ef7\uff0c\u6309\u5730\u6696\u94fa\u8bbe\u9762\u79ef\u8ba1<\/td><\/tr>\n    <tr><td>\u9505\u7089\/\u70ed\u6c34\u5668<\/td><td>\u5355\u4ef7\uff08\u4e0d\u6253\u6298\uff09<\/td><\/tr>\n    <tr><td>\u8bbe\u5907\u5bff\u547d\u4f9d\u636e<\/td><td>\u4e3b\u673a\/\u6c34\u6a21\u575720\u5e74+\uff08\u65e5\u7acb\u5b98\u65b9\uff09\uff1b\u71c3\u6c14\u9505\u70897~8\u5e74\uff08GB 17905-2008\uff09<\/td><\/tr>\n  <\/table>\n<\/div>\n\n<div class=\"footer\">\n  <p>\u9f99\u8109\u6696\u901a \u00b7 \u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1 \u00b7 \u59cb\u4e8e2004<\/p>\n  <p>\u65b9\u6848\u8bbe\u8ba1\uff1a\u4f59\u6653\u73b2 | AI\u534f\u4f5c\u5b8c\u6210 \u00b7 2026\u5e747\u67089\u65e5<\/p>\n  <p>\u6240\u6709\u4ef7\u683c\u4ee5\u95e8\u5e97\u5b9e\u9645\u62a5\u4ef7\u4e3a\u51c6\uff0c\u6709\u6548\u671f15\u5929<\/p>\n<\/div>\n\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9526\u6c5f\u5e9c \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66  [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6185","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9526\u6c5f\u5e9c\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff5c\u6210\u90fd\u65e5\u7acb\u4e00\u62d6\u4e94\u5929\u6c1f\u5730\u6c34\u91c7\u6696\u62a5\u4ef7<\/title>\n<meta name=\"description\" content=\"\u9f99\u8109\u6696\u901a\u9526\u6c5f\u5e9c\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4\uff0c\u9002\u914d\u4e94\u53e3\u5e26\u5ba0\u5bb6\u5ead\uff0c\u6db5\u76d6\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u71c3\u6c14\u7089\u91c7\u6696\u7cfb\u7edf\uff0c\u900f\u660e\u62a5\u4ef7\u3001\u80fd\u8017\u53ca20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u5bf9\u6bd4\u91c7\u6696\u6548\u7387\u3001\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u51c0\u5316\u3001\u8bbe\u5907\u5bff\u547d\uff0c\u9644\u6210\u90fd\u65bd\u5de5\u6848\u4f8b\uff0c\u517c\u987e\u9884\u7b97\u4e0e\u957f\u671f\u8282\u80fd\uff0c\u7ed9\u4e1a\u4e3b\u4e13\u4e1a\u9009\u578b\u53c2\u8003\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=6185\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9526\u6c5f\u5e9c\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff5c\u6210\u90fd\u65e5\u7acb\u4e00\u62d6\u4e94\u5929\u6c1f\u5730\u6c34\u91c7\u6696\u62a5\u4ef7\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a\u9526\u6c5f\u5e9c\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4\uff0c\u9002\u914d\u4e94\u53e3\u5e26\u5ba0\u5bb6\u5ead\uff0c\u6db5\u76d6\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u71c3\u6c14\u7089\u91c7\u6696\u7cfb\u7edf\uff0c\u900f\u660e\u62a5\u4ef7\u3001\u80fd\u8017\u53ca20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u5bf9\u6bd4\u91c7\u6696\u6548\u7387\u3001\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u51c0\u5316\u3001\u8bbe\u5907\u5bff\u547d\uff0c\u9644\u6210\u90fd\u65bd\u5de5\u6848\u4f8b\uff0c\u517c\u987e\u9884\u7b97\u4e0e\u957f\u671f\u8282\u80fd\uff0c\u7ed9\u4e1a\u4e3b\u4e13\u4e1a\u9009\u578b\u53c2\u8003\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=6185\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-11T08:33:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185\",\"name\":\"\u9526\u6c5f\u5e9c\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff5c\u6210\u90fd\u65e5\u7acb\u4e00\u62d6\u4e94\u5929\u6c1f\u5730\u6c34\u91c7\u6696\u62a5\u4ef7\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\",\"datePublished\":\"2026-07-11T08:21:24+00:00\",\"dateModified\":\"2026-07-11T08:33:50+00:00\",\"description\":\"\u9f99\u8109\u6696\u901a\u9526\u6c5f\u5e9c\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4\uff0c\u9002\u914d\u4e94\u53e3\u5e26\u5ba0\u5bb6\u5ead\uff0c\u6db5\u76d6\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u71c3\u6c14\u7089\u91c7\u6696\u7cfb\u7edf\uff0c\u900f\u660e\u62a5\u4ef7\u3001\u80fd\u8017\u53ca20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u5bf9\u6bd4\u91c7\u6696\u6548\u7387\u3001\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u51c0\u5316\u3001\u8bbe\u5907\u5bff\u547d\uff0c\u9644\u6210\u90fd\u65bd\u5de5\u6848\u4f8b\uff0c\u517c\u987e\u9884\u7b97\u4e0e\u957f\u671f\u8282\u80fd\uff0c\u7ed9\u4e1a\u4e3b\u4e13\u4e1a\u9009\u578b\u53c2\u8003\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\",\"width\":1240,\"height\":1754},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6185#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9526\u6c5f\u5e9c \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9526\u6c5f\u5e9c\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff5c\u6210\u90fd\u65e5\u7acb\u4e00\u62d6\u4e94\u5929\u6c1f\u5730\u6c34\u91c7\u6696\u62a5\u4ef7","description":"\u9f99\u8109\u6696\u901a\u9526\u6c5f\u5e9c\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4\uff0c\u9002\u914d\u4e94\u53e3\u5e26\u5ba0\u5bb6\u5ead\uff0c\u6db5\u76d6\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u71c3\u6c14\u7089\u91c7\u6696\u7cfb\u7edf\uff0c\u900f\u660e\u62a5\u4ef7\u3001\u80fd\u8017\u53ca20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u5bf9\u6bd4\u91c7\u6696\u6548\u7387\u3001\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u51c0\u5316\u3001\u8bbe\u5907\u5bff\u547d\uff0c\u9644\u6210\u90fd\u65bd\u5de5\u6848\u4f8b\uff0c\u517c\u987e\u9884\u7b97\u4e0e\u957f\u671f\u8282\u80fd\uff0c\u7ed9\u4e1a\u4e3b\u4e13\u4e1a\u9009\u578b\u53c2\u8003\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=6185","og_locale":"zh_CN","og_type":"article","og_title":"\u9526\u6c5f\u5e9c\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff5c\u6210\u90fd\u65e5\u7acb\u4e00\u62d6\u4e94\u5929\u6c1f\u5730\u6c34\u91c7\u6696\u62a5\u4ef7","og_description":"\u9f99\u8109\u6696\u901a\u9526\u6c5f\u5e9c\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4\uff0c\u9002\u914d\u4e94\u53e3\u5e26\u5ba0\u5bb6\u5ead\uff0c\u6db5\u76d6\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u71c3\u6c14\u7089\u91c7\u6696\u7cfb\u7edf\uff0c\u900f\u660e\u62a5\u4ef7\u3001\u80fd\u8017\u53ca20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u5bf9\u6bd4\u91c7\u6696\u6548\u7387\u3001\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u51c0\u5316\u3001\u8bbe\u5907\u5bff\u547d\uff0c\u9644\u6210\u90fd\u65bd\u5de5\u6848\u4f8b\uff0c\u517c\u987e\u9884\u7b97\u4e0e\u957f\u671f\u8282\u80fd\uff0c\u7ed9\u4e1a\u4e3b\u4e13\u4e1a\u9009\u578b\u53c2\u8003\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=6185","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-11T08:33:50+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=6185","url":"https:\/\/longmai-nt.com\/?page_id=6185","name":"\u9526\u6c5f\u5e9c\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff5c\u6210\u90fd\u65e5\u7acb\u4e00\u62d6\u4e94\u5929\u6c1f\u5730\u6c34\u91c7\u6696\u62a5\u4ef7","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=6185#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=6185#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","datePublished":"2026-07-11T08:21:24+00:00","dateModified":"2026-07-11T08:33:50+00:00","description":"\u9f99\u8109\u6696\u901a\u9526\u6c5f\u5e9c\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4\uff0c\u9002\u914d\u4e94\u53e3\u5e26\u5ba0\u5bb6\u5ead\uff0c\u6db5\u76d6\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u71c3\u6c14\u7089\u91c7\u6696\u7cfb\u7edf\uff0c\u900f\u660e\u62a5\u4ef7\u3001\u80fd\u8017\u53ca20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u5bf9\u6bd4\u91c7\u6696\u6548\u7387\u3001\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u51c0\u5316\u3001\u8bbe\u5907\u5bff\u547d\uff0c\u9644\u6210\u90fd\u65bd\u5de5\u6848\u4f8b\uff0c\u517c\u987e\u9884\u7b97\u4e0e\u957f\u671f\u8282\u80fd\uff0c\u7ed9\u4e1a\u4e3b\u4e13\u4e1a\u9009\u578b\u53c2\u8003\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=6185#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=6185"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=6185#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","width":1240,"height":1754},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=6185#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9526\u6c5f\u5e9c \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6185"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6185\/revisions"}],"predecessor-version":[{"id":6186,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6185\/revisions\/6186"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}