{"id":6342,"date":"2026-07-12T22:49:33","date_gmt":"2026-07-12T14:49:33","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=6342"},"modified":"2026-10-21T14:28:42","modified_gmt":"2026-10-21T06:28:42","slug":"6342-2","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=6342","title":{"rendered":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<style>\n.lmac-wrap {\n  --lmac-pri: #0d4f7e;\n  --lmac-pri-lt: #1a7fc4;\n  --lmac-pri-dk: #083458;\n  --lmac-acc: #c8a85e;\n  --lmac-bg: #f5f7fa;\n  --lmac-card: #ffffff;\n  --lmac-text: #2c3e50;\n  --lmac-text-lt: #6b7c93;\n  --lmac-border: #e2e8f0;\n  --lmac-succ: #27ae60;\n  --lmac-warn: #f39c12;\n  --lmac-radius: 12px;\n  --lmac-shadow: 0 4px 24px rgba(0,0,0,0.06);\n  --lmac-maxw: 1100px;\n  display: block;\n  font-family: -apple-system, BlinkMacSystemFont, \"PingFang SC\", \"Microsoft YaHei\", \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 15px;\n  line-height: 1.7;\n  color: var(--lmac-text);\n  background: var(--lmac-bg);\n  max-width: 100%;\n  overflow-x: hidden;\n  scroll-behavior: smooth;\n}\n.lmac-wrap * { box-sizing: border-box; }\n.lmac-wrap img { max-width: 100%; height: auto; display: block; }\n.lmac-wrap table { width: 100%; border-collapse: collapse; overflow-x: auto; display: block; border: none; }\n.lmac-wrap th, .lmac-wrap td { border: none; vertical-align: middle; }\n.lmac-wrap .lmac-section[id] { scroll-margin-top: 90px; }\n\n.lmac-hero {\n  background: linear-gradient(135deg, var(--lmac-pri-dk) 0%, var(--lmac-pri) 50%, #0b2a44 100%);\n  padding: 64px 24px 56px; text-align: center; position: relative; overflow: hidden;\n  color: #fff !important;\n}\n.lmac-hero h1, .lmac-hero p, .lmac-hero span, .lmac-hero strong, .lmac-hero em,\n.lmac-hero .lmac-hero-title, .lmac-hero .lmac-hero-sub, .lmac-hero .lmac-badge,\n.lmac-hero .lmac-accent { color: #fff !important; }\n.lmac-hero .lmac-hero-sub, .lmac-hero .lmac-hero-sub * { color: rgba(255,255,255,0.7) !important; }\n.lmac-hero * { color: #fff !important; }\n.lmac-hero-title { font-size: clamp(26px,4vw,38px); font-weight: 800; letter-spacing: 2px; margin: 0 0 10px; line-height: 1.3; }\n.lmac-hero-title .lmac-accent { color: var(--lmac-acc) !important; }\n.lmac-hero-sub { font-size: 15px; margin: 0 0 18px; line-height: 1.6; }\n.lmac-hero-badges { display: flex; gap: 10px; justify-content: center; flex-wrap: wrap; }\n.lmac-badge { background: rgba(255,255,255,0.12); padding: 5px 16px; border-radius: 20px; font-size: 12px; border: 1px solid rgba(255,255,255,0.15); line-height: 1.5; }\n\n.lmac-container { max-width: var(--lmac-maxw); margin: 0 auto; padding: 0 24px; }\n.lmac-section { padding: 48px 0; }\n.lmac-section + .lmac-section { border-top: 1px solid var(--lmac-border); }\n.lmac-section-title { font-size: 24px; font-weight: 700; color: var(--lmac-pri-dk); margin: 0 0 8px; display: flex; align-items: center; gap: 10px; line-height: 1.4; }\n.lmac-section-num { display: inline-flex; align-items: center; justify-content: center; width: 32px; height: 32px; border-radius: 8px; background: var(--lmac-pri); color: #fff !important; font-size: 15px; flex-shrink: 0; line-height: 1; }\n.lmac-section-desc { color: var(--lmac-text-lt); font-size: 14px; margin: 0 0 28px; line-height: 1.7; }\n\n.lmac-nap-bar { background: var(--lmac-card); border-radius: var(--lmac-radius); box-shadow: var(--lmac-shadow); padding: 20px 24px; margin-bottom: 24px; display: flex; flex-wrap: wrap; gap: 16px 32px; justify-content: center; border-left: 4px solid var(--lmac-acc); }\n.lmac-nap-item { display: flex; align-items: center; gap: 8px; font-size: 14px; line-height: 1.5; }\n.lmac-nap-icon { font-size: 18px; flex-shrink: 0; }\n.lmac-nap-label { color: var(--lmac-text-lt); font-size: 12px; }\n.lmac-nap-value { color: var(--lmac-text); font-weight: 600; }\n\n.lmac-std-grid { display: grid; grid-template-columns: 130px 1fr; gap: 0; border-radius: var(--lmac-radius); overflow: hidden; box-shadow: var(--lmac-shadow); margin-bottom: 24px; }\n.lmac-std-label { background: var(--lmac-pri); color: #fff !important; padding: 14px 16px; font-weight: 700; font-size: 14px; display: flex; align-items: center; border-bottom: 1px solid rgba(255,255,255,0.1); line-height: 1.5; }\n.lmac-std-label:last-child { border-bottom: none; }\n.lmac-std-label small { font-weight: 400; font-size: 12px; opacity: .8; display: block; color: rgba(255,255,255,0.85) !important; }\n.lmac-std-value { background: var(--lmac-card); padding: 14px 18px; font-size: 14px; border-bottom: 1px solid var(--lmac-border); line-height: 1.8; }\n.lmac-std-value:last-child { border-bottom: none; }\n.lmac-std-value ul { list-style: none; padding: 0; margin: 0; }\n.lmac-std-value ul li { padding: 1px 0; line-height: 1.7; }\n.lmac-std-value ul li::before { content: '\\2713 '; color: var(--lmac-succ); font-weight: 700; }\n\n.lmac-img-card { background: var(--lmac-card); border-radius: var(--lmac-radius); box-shadow: var(--lmac-shadow); overflow: hidden; }\n.lmac-img-card img { width: 100%; aspect-ratio: 16\/10; object-fit: cover; }\n.lmac-img-caption { padding: 12px 16px; font-size: 13px; color: var(--lmac-text-lt); border-top: 1px solid var(--lmac-border); line-height: 1.6; }\n.lmac-img-caption strong { color: var(--lmac-text); }\n\n.lmac-grid-2 { display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin: 24px 0; }\n.lmac-grid-3 { display: grid; grid-template-columns: 1fr 1fr 1fr; gap: 20px; margin: 24px 0; }\n.lmac-grid-2col { display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin-top: 24px; }\n.lmac-grid-3col { display: grid; grid-template-columns: 1fr 1fr 1fr; gap: 20px; margin-top: 24px; }\n.lmac-grid-4 { display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin: 24px 0; }\n@media (min-width:768px) { .lmac-grid-4 { grid-template-columns: 1fr 1fr 1fr 1fr; } }\n\n.lmac-flow { display: flex; gap: 8px; align-items: center; flex-wrap: wrap; margin: 20px 0; }\n.lmac-flow-step { flex: 1; min-width: 120px; background: var(--lmac-card); border-radius: 10px; padding: 16px; text-align: center; box-shadow: var(--lmac-shadow); border-left: 3px solid var(--lmac-pri); }\n.lmac-flow-num { font-size: 22px; font-weight: 800; color: var(--lmac-pri); line-height: 1.3; }\n.lmac-flow-desc { font-size: 13px; color: var(--lmac-text); margin-top: 4px; line-height: 1.5; }\n.lmac-flow-desc small { font-size: 12px; color: var(--lmac-text-lt); }\n.lmac-flow-arrow { color: var(--lmac-pri-lt); font-size: 22px; font-weight: 300; flex-shrink: 0; line-height: 1; }\n\n.lmac-norm { background: var(--lmac-card); border-radius: var(--lmac-radius); box-shadow: var(--lmac-shadow); padding: 24px; margin-bottom: 20px; border-left: 4px solid var(--lmac-pri); }\n.lmac-norm-h { font-size: 16px; color: var(--lmac-pri); margin: 0 0 8px; line-height: 1.5; font-weight: 700; }\n.lmac-norm ul { list-style: none; padding: 0; margin: 0; }\n.lmac-norm ul li { padding: 3px 0; font-size: 14px; line-height: 1.8; }\n.lmac-norm ul li::before { content: '\\25B8 '; color: var(--lmac-pri-lt); }\n.lmac-norm p { font-size: 14px; line-height: 1.8; margin: 0 0 8px; }\n\n.lmac-tag { display: inline-block; background: #eef4ff; color: var(--lmac-pri); font-size: 12px; padding: 2px 10px; border-radius: 4px; margin-right: 6px; line-height: 1.6; }\n.lmac-tag-gold { background: #fef8e8; color: #9a7b3c; }\n\n.lmac-summary-grid { display: grid; grid-template-columns: repeat(3,1fr); gap: 20px; margin: 24px 0; }\n.lmac-summary-card { background: var(--lmac-card); border-radius: var(--lmac-radius); box-shadow: var(--lmac-shadow); padding: 28px 20px; text-align: center; border-top: 4px solid var(--lmac-pri); }\n.lmac-summary-icon { font-size: 36px; line-height: 1; margin-bottom: 10px; }\n.lmac-summary-card h4 { font-size: 16px; color: var(--lmac-pri-dk); margin: 0 0 6px; font-weight: 700; line-height: 1.4; }\n.lmac-summary-card p { font-size: 13px; color: var(--lmac-text-lt); line-height: 1.7; margin: 0; }\n\n.lmac-norm-gold { border-left-color: var(--lmac-acc); }\n.lmac-norm-gold .lmac-norm-h { color: #9a7b3c; }\n\n.lmac-faq-item { background: var(--lmac-card); border-radius: var(--lmac-radius); box-shadow: var(--lmac-shadow); margin-bottom: 12px; overflow: hidden; }\n.lmac-faq-q { padding: 16px 20px; font-weight: 700; font-size: 15px; color: var(--lmac-pri-dk); cursor: pointer; display: flex; justify-content: space-between; align-items: center; border-bottom: 1px solid var(--lmac-border); background: #fafbfc; }\n.lmac-faq-q .lmac-faq-icon { color: var(--lmac-pri); font-size: 18px; flex-shrink: 0; }\n.lmac-faq-a { padding: 16px 20px; font-size: 14px; line-height: 1.8; color: var(--lmac-text); }\n\n.lmac-footer { background: var(--lmac-pri-dk); color: rgba(255,255,255,0.6) !important; text-align: center; padding: 32px 20px; font-size: 13px; line-height: 1.8; }\n.lmac-footer * { color: rgba(255,255,255,0.6) !important; }\n.lmac-footer strong { color: var(--lmac-acc) !important; }\n\n@media (max-width: 767px) {\n  .lmac-wrap { font-size: 14px; }\n  .lmac-hero { padding: 40px 20px 36px; }\n  .lmac-std-grid { grid-template-columns: 1fr; }\n  .lmac-std-label { padding: 10px 14px; }\n  .lmac-grid-2, .lmac-grid-3, .lmac-grid-2col, .lmac-grid-3col, .lmac-grid-4 { grid-template-columns: 1fr; }\n  .lmac-summary-grid { grid-template-columns: 1fr; }\n  .lmac-flow { flex-direction: column; }\n  .lmac-flow-arrow { transform: rotate(90deg); }\n  .lmac-section { padding: 32px 0; }\n  .lmac-section-title { font-size: 20px; }\n  .lmac-nap-bar { flex-direction: column; gap: 10px; }\n}\n\n\/* \u6807\u9898\u8bed\u4e49\u6807\u7b7e\u6837\u5f0f\u4fdd\u62a4\uff08\u4fdd\u6301\u4e0e\u539f\u6709\u89c6\u89c9\u4e00\u81f4\uff09 *\/\n.lmac-wrap h2.lmac-section-title,\n.lmac-wrap h3.lmac-norm-h { display: flex; border: none; background: none; text-decoration: none; }\n.lmac-wrap h2.lmac-section-title { font-size: 24px; font-weight: 700; color: #083458; margin: 0 0 8px; align-items: center; gap: 10px; line-height: 1.4; padding: 0; }\n.lmac-wrap h3.lmac-norm-h { font-size: 16px; font-weight: 700; color: #0d4f7e; margin: 0 0 8px; line-height: 1.5; padding: 0; align-items: center; gap: 0; }\n<\/style>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"HVACBusiness\",\n  \"name\": \"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"alternateName\": \"\u9f99\u8109\u6696\u901a\",\n  \"description\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c2004 \u5e74\u8d77\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf\u3002\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u65b0\u98ce\u3001\u51c0\u6c34\u9500\u552e\u8bbe\u8ba1\u5b89\u88c5\u552e\u540e\u4e00\u7ad9\u5f0f\u670d\u52a1\u3002\",\n  \"url\": \"https:\/\/longmai-nt.com\/?page_id=6342\",\n  \"telephone\": [\n    \"028-86131795\",\n    \"028-65272586\"\n  ],\n  \"foundingDate\": \"2004\",\n  \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\",\n  \"areaServed\": [\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u6210\u90fd\u5e02\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u9ad8\u65b0\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u6b66\u4faf\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u9526\u6c5f\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u9752\u7f8a\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u91d1\u725b\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u6210\u534e\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u53cc\u6d41\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u9f99\u6cc9\u9a7f\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u90eb\u90fd\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u6e29\u6c5f\u533a\"\n    },\n    {\n      \"@type\": \"City\",\n      \"name\": \"\u65b0\u90fd\u533a\"\n    }\n  ],\n  \"address\": [\n    {\n      \"@type\": \"PostalAddress\",\n      \"streetAddress\": \"\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348\",\n      \"addressLocality\": \"\u6210\u90fd\u5e02\",\n      \"addressRegion\": \"\u56db\u5ddd\u7701\",\n      \"addressCountry\": \"CN\"\n    },\n    {\n      \"@type\": \"PostalAddress\",\n      \"streetAddress\": \"\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135\",\n      \"addressLocality\": \"\u6210\u90fd\u5e02\",\n      \"addressRegion\": \"\u56db\u5ddd\u7701\",\n      \"addressCountry\": \"CN\"\n    }\n  ],\n  \"openingHoursSpecification\": [\n    {\n      \"@type\": \"OpeningHoursSpecification\",\n      \"dayOfWeek\": [\n        \"Monday\",\n        \"Tuesday\",\n        \"Wednesday\",\n        \"Thursday\",\n        \"Friday\"\n      ],\n      \"opens\": \"10:00\",\n      \"closes\": \"18:00\"\n    },\n    {\n      \"@type\": \"OpeningHoursSpecification\",\n      \"dayOfWeek\": [\n        \"Saturday\",\n        \"Sunday\"\n      ],\n      \"opens\": \"10:00\",\n      \"closes\": \"18:00\"\n    }\n  ],\n  \"hasOfferCatalog\": {\n    \"@type\": \"OfferCatalog\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\u670d\u52a1\",\n    \"itemListElement\": [\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u8bbe\u8ba1\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u65bd\u5de5\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u5730\u6696\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u65bd\u5de5\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u660e\u88c5\u6696\u6c14\u5b89\u88c5\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u65b0\u98ce\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u5b89\u88c5\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u51c0\u6c34\u7cfb\u7edf\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u6e05\u6d17\u4fdd\u517b\"\n        }\n      },\n      {\n        \"@type\": \"Offer\",\n        \"itemOffered\": {\n          \"@type\": \"Service\",\n          \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u6545\u969c\u7ef4\u4fee\"\n        }\n      }\n    ]\n  }\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6210\u90fd\u88c5\u4fee\uff0c\u4e2d\u592e\u7a7a\u8c03\u4ec0\u4e48\u65f6\u5019\u8fdb\u573a\u5b89\u88c5\u6700\u5408\u9002\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e2d\u592e\u7a7a\u8c03\u5728\u6c34\u7535\u6539\u9020\u5b8c\u6210\u540e\u3001\u540a\u9876\u5c01\u677f\u524d \u8fdb\u573a\u5b89\u88c5\uff0c\u4e00\u822c\u662f\u88c5\u4fee\u5f00\u5de5\u540e\u7684 \u7b2c2-3\u5468\u3002\u9f99\u8109\u6696\u901a\u4f1a\u4e3b\u52a8\u4e0e\u88c5\u4fee\u516c\u53f8\u534f\u8c03\u65bd\u5de5\u8282\u70b9\uff0c\u786e\u4fdd\u7ba1\u9053\u94fa\u8bbe\u5b89\u6392\u5728\u540a\u9876\u5de5\u5e8f\u4e4b\u524d\uff0c\u907f\u514d\u8fd4\u5de5\u3002\u5efa\u8bae\u5728\u88c5\u4fee\u8bbe\u8ba1\u9636\u6bb5\u5c31\u786e\u5b9a\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\uff0c\u63d0\u524d\u9884\u7559\u98ce\u53e3\u548c\u68c0\u4fee\u53e3\u4f4d\u7f6e\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6210\u90fd\u8001\u623f\u5b50\u3001\u8001\u623f\u7ffb\u65b0\u53ef\u4ee5\u52a0\u88c5\u4e2d\u592e\u7a7a\u8c03\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u53ef\u4ee5\u3002\u9700\u8981\u8bc4\u4f30\u5c42\u9ad8\u3001\u6881\u4f4d\u548c\u73b0\u6709\u7535\u8def\u3002\u5982\u679c\u5168\u5c4b\u540a\u9876\u6761\u4ef6\u4e0d\u8db3\uff0c\u53ef\u9009\u62e9\u65e5\u7acb\u98ce\u7ba1\u673a\u65b9\u6848\uff08\u5ba2\u9910\u5385\u4e00\u53f0+\u5367\u5ba4\u58c1\u6302\u673a\uff09\uff0c\u65e0\u9700\u5168\u5c4b\u540a\u9876\u5373\u53ef\u4eab\u53d7\u4e2d\u592e\u7a7a\u8c03\u6548\u679c\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u8bc4\u4f30\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u8d28\u4fdd\u591a\u4e45\uff1f\u6f0f\u6c34\u600e\u4e48\u529e\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u9f99\u8109\u6696\u901a\u63d0\u4f9b\uff1a\u4e3b\u673a\u8d28\u4fdd5\u5e74 + \u7cfb\u7edf\u8d28\u4fdd2\u5e74 + \u957f\u671f\u7ef4\u62a4\u670d\u52a1\u3002\u9690\u853d\u5de5\u7a0b\u901a\u8fc724\u5c0f\u65f6\u4fdd\u538b\u6d4b\u8bd5+\u6ee1\u6c34\u6392\u6c34\u8bd5\u9a8c\u53cc\u91cd\u9a8c\u8bc1\u3002\u51b7\u51dd\u6c34\u7ba1\u4e25\u7981\u63a5\u5165\u6c61\u6c34\u7ba1\u9053\uff0c\u8bbe\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\u4fdd\u6301\u6c14\u538b\u5e73\u8861\u3002\u4e07\u4e00\u51fa\u73b0\u95ee\u9898\uff1a\u540c\u57ce24\u5c0f\u65f6\u552e\u540e\u54cd\u5e94\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u5c01\u677f\u4ee5\u540e\u624d\u53d1\u73b0\u95ee\u9898\u600e\u4e48\u529e\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u8fd9\u6b63\u662f\u628a\u9a8c\u6536\u653e\u5728\u5c01\u677f\u524d\u7684\u539f\u56e0\u3002\u9f99\u8109\u6696\u901a\u5728\u5c01\u677f\u524d\u5b8c\u6210\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\uff0c\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u9010\u9879\u7b7e\u5b57\uff0c\u538b\u529b\u8868\u4ece\u5b89\u88c5\u5230\u5165\u4f4f\u6301\u7eed\u6302\u538b\uff0c\u6f0f\u70b9\u5728\u5c01\u677f\u524d\u5c31\u80fd\u53d1\u73b0\u3002\u5c01\u677f\u4e4b\u540e\u518d\u51fa\u95ee\u9898\uff0c\u62c6\u9876\u7684\u6210\u672c\u6bd4\u88c5\u7684\u65f6\u5019\u9ad8\u5f97\u591a\u3002\u672c\u9875\u6bcf\u4e00\u6b65\u7684\u9a8c\u6536\u6807\u51c6\uff0c\u53e6\u89c1\u300a\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\u300b\u9010\u6761\u5bf9\u7167\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5176\u4ed6\u54c1\u724c\u6bd4\uff0c\u672c\u5730\u5b89\u88c5\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u65e5\u7acb\u6838\u5fc3\u4f18\u52bf\uff1a\u6da1\u65cb\u538b\u7f29\u673a\u6280\u672f\u3001\u5168\u76f4\u6d41\u53d8\u9891\uff0c\u9759\u97f3\u6570\u503c\u968f\u673a\u578b\u548c\u5185\u673a\u89c4\u683c\u4e0d\u540c\u5206\u6863\uff08\u4ee5\u5b98\u65b9\u516c\u5e03\u4e3a\u51c6\uff09\u3002\u9f99\u8109\u6696\u901a\u5b89\u88c5\u4f18\u52bf\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u539f\u5382\u914d\u4ef6\u76f4\u4f9b\u3001\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6\u65bd\u5de5\uff08\u6c2e\u6c14\u4fdd\u62a4\u710a+4.15MPa \u4fdd\u538b24\u5c0f\u65f6\uff09\u3001\u5168\u7a0b\u53ef\u89c6\u65bd\u5de5\u7167\u7247\u5b9e\u65f6\u53d1\u7fa4\u3001\u4e09\u65b9\u9a8c\u6536\u8d28\u4fdd\u534f\u8bae\u4e00\u5e94\u4ff1\u5168\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n\n<div class=\"lmac-wrap\">\n\n<div class=\"lmac-hero\">\n  <p class=\"lmac-hero-title\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u5168\u8fc7\u7a0b \u00b7 \u9f99\u8109\u6696\u901a\u516b\u6b65\u4ea4\u4ed8\u6d41\u7a0b<\/p>\n  <p class=\"lmac-hero-sub\">\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u6559\u5b66\uff0c\u6bcf\u4e00\u6b65\u8c01\u505a\u3001\u7b7e\u4ec0\u4e48\u5b57\u3001\u7559\u4ec0\u4e48\u51ed\u636e \u00b7 2004 \u5e74\u8d77\u6210\u90fd\u672c\u5730\u6696\u901a\u670d\u52a1\u5546<\/p>\n  <div class=\"lmac-hero-badges\">\n    <span class=\"lmac-badge\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d<\/span>\n    <span class=\"lmac-badge\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \/ \u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546<\/span>\n    <span class=\"lmac-badge\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/span>\n    <span class=\"lmac-badge\">\u6c2e\u6c14\u4fdd\u62a4\u710a<\/span>\n    <span class=\"lmac-badge\">\u5168\u7a0b\u53ef\u89c6<\/span>\n    <span class=\"lmac-badge\">\u4e09\u65b9\u7b7e\u5b57\u9a8c\u6536<\/span>\n    <span class=\"lmac-badge\">\u540c\u57ce 24 \u5c0f\u65f6\u552e\u540e<\/span>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-container\">\n\n<div class=\"lmac-section\" id=\"sec-local\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u4e00<\/span> \u9f99\u8109\u6696\u901a \u00b7 \u672c\u5730\u670d\u52a1\u4fe1\u606f<\/h2>\n  <p class=\"lmac-section-desc\">\u6210\u90fd\u672c\u5730\u6696\u901a\u4e00\u7ad9\u5f0f\u670d\u52a1\u5546\uff0c\u53cc\u5b9e\u4f53\u95e8\u5e97\uff0c\u8986\u76d6\u5168\u57ce\u4e3b\u8981\u57ce\u533a\u3002\u5230\u5e97\u53ef\u67e5\u3001\u53ef\u770b\u5b9e\u673a\u3002<\/p>\n\n  <div class=\"lmac-nap-bar\">\n    <div class=\"lmac-nap-item\">\n      <span class=\"lmac-nap-icon\">\ud83d\udccd<\/span>\n      <div><div class=\"lmac-nap-label\">\u5357\u5bcc\u68ee\u5e97<\/div><div class=\"lmac-nap-value\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<\/div><\/div>\n    <\/div>\n    <div class=\"lmac-nap-item\">\n      <span class=\"lmac-nap-icon\">\ud83d\udccd<\/span>\n      <div><div class=\"lmac-nap-label\">\u5317\u5bcc\u68ee\u5e97<\/div><div class=\"lmac-nap-value\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135<\/div><\/div>\n    <\/div>\n    <div class=\"lmac-nap-item\">\n      <span class=\"lmac-nap-icon\">\ud83d\udcde<\/span>\n      <div><div class=\"lmac-nap-label\">\u54a8\u8be2\u70ed\u7ebf<\/div><div class=\"lmac-nap-value\"><a href=\"tel:02886131795\">028-86131795<\/a>\uff08\u5357\uff09<br><a href=\"tel:02865272586\">028-65272586<\/a>\uff08\u5317\uff09<\/div><\/div>\n    <\/div>\n    <div class=\"lmac-nap-item\">\n      <span class=\"lmac-nap-icon\">\ud83d\udd51<\/span>\n      <div><div class=\"lmac-nap-label\">\u8425\u4e1a\u65f6\u95f4<\/div><div class=\"lmac-nap-value\">\u5357\u5bcc\u68ee\uff1a\u5468\u4e00\u81f3\u5468\u4e94 10:00\u201318:00<br>\u5317\u5bcc\u68ee\uff1a\u5468\u4e00\u81f3\u5468\u65e5 10:00\u201318:00<br>\u8282\u5047\u65e5 10:00\u201319:00<\/div><\/div>\n    <\/div>\n    <div class=\"lmac-nap-item\">\n      <span class=\"lmac-nap-icon\">\ud83d\ude9a<\/span>\n      <div><div class=\"lmac-nap-label\">\u670d\u52a1\u8303\u56f4<\/div><div class=\"lmac-nap-value\">\u6210\u90fd\u5168\u57df \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<br>\u540c\u57ce 24 \u5c0f\u65f6\u552e\u540e\u54cd\u5e94<\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-grid-2col\">\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u670d\u52a1\u8986\u76d6\u533a\u57df<\/h3>\n      <ul>\n        <li><strong>\u6838\u5fc3\u57ce\u533a\uff1a<\/strong>\u6b66\u4faf\u533a\u3001\u9ad8\u65b0\u533a\u3001\u9526\u6c5f\u533a\u3001\u9752\u7f8a\u533a\u3001\u91d1\u725b\u533a\u3001\u6210\u534e\u533a<\/li>\n        <li><strong>\u8fd1\u90ca\u57ce\u533a\uff1a<\/strong>\u5929\u5e9c\u65b0\u533a\u3001\u53cc\u6d41\u533a\u3001\u9f99\u6cc9\u9a7f\u533a\u3001\u90eb\u90fd\u533a\u3001\u6e29\u6c5f\u533a\u3001\u65b0\u90fd\u533a<\/li>\n        <li><strong>\u8fdc\u90ca\/\u53bf\u7ea7\u5e02\uff1a<\/strong>\u90fd\u6c5f\u5830\u3001\u5f6d\u5dde\u3001\u909b\u5d03\u3001\u5d07\u5dde\u3001\u91d1\u5802\u3001\u65b0\u6d25<\/li>\n        <li>\u670d\u52a1\u534a\u5f84\uff1a\u6210\u90fd\u5e02\u533a 60 \u516c\u91cc\u8303\u56f4\u5185\u5747\u53ef\u4e0a\u95e8\u52d8\u6d4b\u5b89\u88c5<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u672c\u5730\u670d\u52a1\u7279\u8272<\/h3>\n      <ul>\n        <li>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u65b9\u6848\u8bbe\u8ba1<\/li>\n        <li>\u53cc\u95e8\u5e97\u5c55\u5385\u5b9e\u673a\u4f53\u9a8c\uff08\u53ef\u9884\u7ea6\u5230\u5e97\uff09<\/li>\n        <li>\u672c\u5730\u4ed3\u5e93\uff0c\u5e38\u7528\u914d\u4ef6\u73b0\u8d27\u4f9b\u5e94<\/li>\n        <li>\u652f\u6301\u8282\u5047\u65e5\u65bd\u5de5\uff08\u9700\u4e0e\u88c5\u4fee\u65b9\u534f\u8c03\uff09<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-intro\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u4e8c<\/span> \u8fd9\u9875\u8bb2\"\u6d41\u7a0b\u4e0e\u8d23\u4efb\"\uff0c\u9a8c\u6536\u6807\u51c6\u770b\u53e6\u4e00\u9875<\/h2>\n<p>\u516b\u6b65\u6d41\u7a0b\u91cc\uff0c\u7b2c\u4e00\u6b65\u662f\u8bbe\u8ba1\uff0c\u4e0d\u662f\u8fdb\u573a\u3002\u65b9\u6848\u6ca1\u5b9a\u6e05\u695a\u5c31\u5f00\u5de5\uff0c\u540e\u9762\u6bcf\u4e00\u6b65\u90fd\u5728\u8865\u7a9f\u7abf\u3002\u8fd9\u7bc7\u8bb2\u4e00\u5957\u4e2d\u592e\u7a7a\u8c03\u4ece\u52d8\u6d4b\u5230\u8bbe\u8ba1\u3001\u518d\u5230\u4ea4\u4ed8\u9a8c\u6536\uff0c\u516b\u6b65\u600e\u4e48\u8d70\u5b8c\u3002<\/p>\n  <p class=\"lmac-section-desc\">\u88c5\u4e00\u5957\u4e2d\u592e\u7a7a\u8c03\uff0c\u4e0d\u662f\u4e00\u4e2a\u5e08\u5085\u88c5\u51e0\u53f0\u673a\u5668\u7684\u4e8b\u3002\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\uff0c\u4e2d\u95f4\u6709\u516b\u4e2a\u73af\u8282\uff0c\u6bcf\u4e2a\u73af\u8282\u8c01\u505a\u3001\u505a\u5b8c\u7b7e\u4ec0\u4e48\u5b57\u3001\u7559\u4e0b\u4ec0\u4e48\u51ed\u636e\uff0c\u8fd9\u4e00\u9875\u4e00\u6b21\u8bb2\u6e05\u3002<\/p>\n  <div class=\"lmac-norm lmac-norm-gold\">\n    <h3 class=\"lmac-norm-h\">\u548c\u522b\u4eba\u4e0d\u4e00\u6837\u7684\u5730\u65b9<\/h3>\n    <ul>\n      <li><strong>\u4e0d\u662f\"\u5305\u7ed9\u65bd\u5de5\u961f\u5c31\u5b8c\u4e8b\"\uff1a<\/strong>\u6bcf\u4e00\u6b65\u90fd\u5bf9\u7740\u68c0\u67e5\u5355\u8d70\uff0c\u524d\u4e00\u6b65\u4e0d\u5408\u683c\uff0c\u4e0d\u8fdb\u5165\u4e0b\u4e00\u6b65<\/li>\n      <li><strong>\u4e0d\u662f\"\u88c5\u5b8c\u518d\u9a8c\u6536\"\uff1a<\/strong>\u9690\u853d\u5de5\u7a0b\u5c01\u677f\u524d\u5148\u9a8c\u6536\uff0c\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u9010\u9879\u7b7e\u5b57<\/li>\n      <li><strong>\u4e0d\u662f\"\u51fa\u4e86\u4e8b\u518d\u8bf4\"\uff1a<\/strong>\u538b\u529b\u8868\u4ece\u5b89\u88c5\u5230\u5165\u4f4f\u6301\u7eed\u6302\u538b\uff0c\u6f0f\u70b9\u5728\u5c01\u677f\u524d\u5c31\u80fd\u53d1\u73b0<\/li>\n    <\/ul>\n    <p style=\"margin-top:8px;font-size:13px;color:var(--lmac-text-lt);\">\u6bcf\u4e00\u6b65\u7684\u9a8c\u6536\u8981\u6c42\uff0841 \u6761\uff09\uff0c\u53e6\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=11380\">\u300a\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\u300b<\/a>\uff0c\u4e24\u9875\u914d\u5408\u770b\u2014\u2014\u672c\u9875\u8bb2\u6d41\u7a0b\uff0c\u90a3\u9875\u8bb2\u6807\u51c6\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-design\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u4e09<\/span> \u7b2c\u4e00\u6b65\uff1a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u65b9\u6848\u8bbe\u8ba1<\/h2>\n  <p class=\"lmac-section-desc\">\u5148\u770b\u73b0\u573a\u518d\u51fa\u56fe\u3002\u6237\u578b\u3001\u5c42\u9ad8\u3001\u6881\u4f4d\u3001\u7535\u6e90\u3001\u540a\u9876\u6761\u4ef6\uff0c\u4e00\u9879\u9879\u91cf\u6e05\u695a\uff0c\u65b9\u6848\u624d\u843d\u5f97\u4e86\u5730\u3002<\/p>\n\n  <div class=\"lmac-grid-2\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5e73\u9762\u5e03\u7f6e\u8bbe\u8ba1\u56fe\" loading=\"lazy\" style=\"aspect-ratio:4\/3;\">\n      <div class=\"lmac-img-caption\"><strong>\u4e2d\u592e\u7a7a\u8c03\u5e73\u9762\u5e03\u7f6e\u56fe<\/strong><br>\u5ba2\u6237\u4e13\u5c5e\u65bd\u5de5\u56fe\u7eb8\uff0c\u7cbe\u786e\u6807\u6ce8\u5185\u673a\u4f4d\u7f6e\u3001\u7ba1\u8def\u8d70\u5411\u3001\u98ce\u53e3\u5c3a\u5bf8<\/div>\n    <\/div>\n    <div class=\"lmac-norm\" style=\"display:flex;flex-direction:column;justify-content:center;\">\n      <h3 class=\"lmac-norm-h\">\u8bbe\u8ba1\u65b9\u6848\u5305\u542b\u5185\u5bb9<\/h3>\n      <ul>\n        <li>\u5404\u623f\u95f4\u5185\u673a\u5b9a\u4f4d\uff08\u578b\u53f7 \/ \u80fd\u529b\u6807\u6ce8\uff09<\/li>\n        <li>\u94dc\u7ba1\u4e3b\u7ba1 \/ \u5206\u6b67\u7ba1\u8d70\u5411\u793a\u610f<\/li>\n        <li>\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u53ca\u6392\u6c34\u8def\u5f84<\/li>\n        <li>\u5916\u673a\u4f4d\u7f6e\u53ca\u7535\u6e90\u9884\u7559\u6807\u6ce8<\/li>\n        <li>\u98ce\u53e3\u5c3a\u5bf8\u3001\u68c0\u4fee\u53e3\u4f4d\u7f6e<\/li>\n        <li>\u7ebf\u63a7\u5668\u9884\u7559\u4f4d\u7f6e<\/li>\n      <\/ul>\n      <p style=\"margin-top:8px;font-size:13px;color:var(--lmac-text-lt);\">\u51fa\u56fe\u540e\u7531\u5de5\u7a0b\u5e08\u3001\u5ba2\u6237\u3001\u88c5\u4fee\u8d1f\u8d23\u4eba\u4e09\u65b9\u73b0\u573a\u5b9a\u4f4d\u786e\u8ba4\uff0c\u786e\u4fdd\u96f6\u8fd4\u5de5\u3002<\/p>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-norm\">\n    <h3 class=\"lmac-norm-h\">\u62a5\u4ef7\u600e\u4e48\u7ed9<\/h3>\n    <p>\u8d39\u7528\u6839\u636e\u6237\u578b\u9762\u79ef\u3001\u7cfb\u7edf\u914d\u7f6e\u3001\u65bd\u5de5\u96be\u5ea6\u9010\u9879\u7b97\u3002\u5148\u51fa\u65b9\u6848\u3001\u518d\u62a5\u4ef7\uff0c<strong>\u5f00\u5de5\u524d\u786e\u8ba4\u603b\u4ef7\uff0c\u5148\u62a5\u4ef7\u540e\u5f00\u5de5<\/strong>\uff0c\u4e0d\u641e\u5f00\u5de5\u540e\u52a0\u4ef7\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-materials\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u56db<\/span> \u7b2c\u4e8c\u6b65\uff1a\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/h2>\n  <p class=\"lmac-section-desc\">\u6bcf\u4e00\u53f0\u8bbe\u5907\u3001\u6bcf\u4e00\u6839\u94dc\u7ba1\u3001\u6bcf\u4e00\u5377\u4fdd\u6e29\u68c9\uff0c\u62cd\u7167\u53d1\u5ba2\u6237\u7fa4\u786e\u8ba4\uff0c\u6e90\u5934\u53ef\u8ffd\u6eaf\u3002<\/p>\n\n  <div class=\"lmac-grid-2\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u8bbe\u5907\u6750\u6599\u8fdb\u573a\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u8bbe\u5907\u6750\u6599\u8fdb\u573a<\/strong><br>\u5185\u5916\u673a\u8bbe\u5907\u8fdb\u573a\uff0c\u578b\u53f7\u94ed\u724c\u9010\u4e00\u62cd\u7167\u786e\u8ba4<\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u58c1\u539a\u68c0\u6d4b\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u94dc\u7ba1\u58c1\u539a\u68c0\u6d4b<\/strong><br>\u54c1\u724c\u3001\u89c4\u683c\u3001\u58c1\u539a\uff08\u5982 9.52\u00d70.8\uff09\u9010\u4e00\u6838\u5bf9\u7559\u5e95<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-norm\">\n    <h3 class=\"lmac-norm-h\">\u6750\u6599\u8fdb\u573a\u4e09\u6838\u5bf9<\/h3>\n    <ul>\n      <li><span class=\"lmac-tag\">\u8bbe\u5907\u6838\u5bf9<\/span>\u6bcf\u4e00\u53f0\u5185\u673a \/ \u5916\u673a\u94ed\u724c\u62cd\u7167\u53d1\u5ba2\u6237\u7fa4\uff0c\u786e\u4fdd\u578b\u53f7\u4e0e\u5408\u540c\u4e00\u81f4<\/li>\n      <li><span class=\"lmac-tag\">\u8f85\u6750\u68c0\u67e5<\/span>\u94dc\u7ba1\u54c1\u724c \/ \u58c1\u539a\u3001\u7535\u7f06\u89c4\u683c\u3001\u4fdd\u6e29\u68c9\u54c1\u724c \/ \u539a\u5ea6\u9010\u4e00\u62cd\u7167\u7559\u5e95<\/li>\n      <li><span class=\"lmac-tag\">\u4f9b\u8d27\u8bc1\u660e<\/span>\u65e5\u7acb\u539f\u5382\u914d\u4ef6\u8bc1\u660e\u3001\u7ecf\u9500\u5546\u6388\u6743\u8bc1\u4e66\u5b58\u6863<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-indoor\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u4e94<\/span> \u7b2c\u4e09\u6b65\uff1a\u4e00\u671f\u9690\u853d\u5de5\u7a0b \u00b7 \u5185\u673a\u5b89\u88c5\u4e0e\u8d70\u7ba1<\/h2>\n  <p class=\"lmac-section-desc\">\u5185\u673a\u5b89\u88c5\u662f\u9690\u853d\u5de5\u7a0b\u6700\u6838\u5fc3\u7684\u73af\u8282\uff0c\u5fc5\u987b\u6c34\u5e73\u56fa\u5b9a\u3001\u53cc\u87ba\u6bcd\u51cf\u9707\u3001\u7ba1\u8def\u89c4\u8303\u8d70\u5411\u3002<\/p>\n\n  <div class=\"lmac-grid-2\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba11\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba1 1<\/strong><br>\u7ba1\u8def\u6a2a\u5e73\u7ad6\u76f4\uff0c\u56fa\u5b9a\u95f4\u8ddd\u5747\u5300<\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd2.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba12\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba1 2<\/strong><br>\u94dc\u7ba1\u4e0e\u4fdd\u6e29\u7ba1\u8d34\u5408\u7d27\u5bc6\uff0c\u65e0\u88f8\u9732<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-grid-4\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u9690\u853d\u5de5\u7a0b\u5b89\u88c51\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u5185\u673a\u9690\u853d\u5b89\u88c5 1<\/strong><\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz4.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u9690\u853d\u5de5\u7a0b\u5b89\u88c52\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u5185\u673a\u9690\u853d\u5b89\u88c5 2<\/strong><\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz3.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u9690\u853d\u5de5\u7a0b\u5b89\u88c53\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u5185\u673a\u9690\u853d\u5b89\u88c5 3<\/strong><\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/strong><br>\u53cc\u87ba\u6bcd + \u53cc\u51cf\u9707\u57ab\u56fa\u5b9a<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-norm\">\n    <h3 class=\"lmac-norm-h\">\u5185\u673a\u5b89\u88c5\u6838\u5fc3\u8981\u6c42<\/h3>\n    <ul>\n      <li><strong>\u5b89\u88c5\u8981\u6c42\uff1a<\/strong>\u4f4d\u7f6e\u6b63\u786e\uff0c\u5fc5\u987b\u6c34\u5e73\u5b89\u88c5<\/li>\n      <li><strong>\u56fa\u5b9a\u65b9\u5f0f\uff1a<\/strong>\u4f7f\u7528\u53cc\u87ba\u6bcd\u3001\u53cc\u51cf\u9707\u57ab\u56fa\u5b9a\uff0c\u786e\u4fdd\u7262\u56fa\u5e76\u51cf\u5c11\u632f\u52a8<\/li>\n      <li><strong>\u68c0\u4fee\u53e3\u9884\u7559\uff1a<\/strong>\u7535\u63a7\u76d2\u53ca\u94dc\u7ba1\u63a5\u5934\u4fa7\u9884\u7559\u4e0d\u5c0f\u4e8e 400\u00d7400mm \u72ec\u7acb\u68c0\u4fee\u53e3<\/li>\n      <li><strong>\u7ba1\u8def\u89c4\u8303\uff1a<\/strong>\u94dc\u7ba1\u8d70\u5411\u6a2a\u5e73\u7ad6\u76f4\uff0c\u7ba1\u5361\u56fa\u5b9a\u95f4\u8ddd\u5747\u5300\uff0c\u4fdd\u6e29\u8fde\u7eed\u65e0\u65ad\u88c2<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-condensate\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u516d<\/span> \u7b2c\u56db\u6b65\uff1a\u51b7\u51dd\u6c34\u7ba1\u65bd\u5de5<\/h2>\n  <p class=\"lmac-section-desc\">\u51b7\u51dd\u6c34\u6392\u6c34\u662f\u4e2d\u592e\u7a7a\u8c03\u6700\u5e38\u89c1\u7684\u9690\u60a3\u70b9\uff0c\u5fc5\u987b\u4fdd\u8bc1\u5761\u5ea6\u3001\u6392\u6c14\u3001\u6392\u6c34\u901a\u7545\u3002<\/p>\n\n  <div class=\"lmac-grid-2\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xhmpqk.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54<\/strong><br>\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\u4fdd\u6301\u6392\u6c34\u7cfb\u7edf\u5185\u5916\u6c14\u538b\u5e73\u8861<\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-frdl.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f<\/strong><br>\u89c4\u8303\u63a5\u5165\u5730\u6f0f\uff0c\u4e25\u7981\u76f4\u63a5\u63a5\u5165\u6c61\u6c34\u7ba1\u9053<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-norm\">\n    <h3 class=\"lmac-norm-h\">\u51b7\u51dd\u6c34\u7ba1\u65bd\u5de5\u89c4\u8303<\/h3>\n    <ul>\n      <li>\u4fdd\u8bc1\u5b89\u88c5\u5761\u5ea6\uff0c\u81ea\u7136\u6392\u6c34\u5761\u5ea6\u4e0d\u5c0f\u4e8e <strong>1%<\/strong>\uff08\u6bcf\u7c73 1cm\uff09<\/li>\n      <li>\u5b8c\u6210\u6ee1\u6c34\u53ca\u6392\u6c34\u8bd5\u9a8c\uff0c\u786e\u4fdd\u6392\u6c34\u7545\u901a\u3001\u65e0\u6e17\u6f0f<\/li>\n      <li>\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\u5b89\u88c5\u5230\u4f4d\uff0c\u4fdd\u6301\u6c14\u538b\u5e73\u8861<\/li>\n      <li>\u4e25\u7981\u5c06\u6392\u6c34\u7ba1\u76f4\u63a5\u63a5\u5165\u6c61\u6c34\u7ba1\u9053\uff0c\u4ee5\u9632\u5f02\u5473<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-welding\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u4e03<\/span> \u7b2c\u4e94\u6b65\uff1a\u94dc\u7ba1\u710a\u63a5 \u00b7 \u6c2e\u6c14\u4fdd\u62a4\u4e0e\u4fdd\u538b<\/h2>\n  <p class=\"lmac-section-desc\">\u94dc\u7ba1\u710a\u63a5\u662f\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u4e2d\u6700\u5173\u952e\u7684\u6280\u672f\u73af\u8282\uff0c\u5fc5\u987b\u4e25\u683c\u6267\u884c\u6c2e\u6c14\u4fdd\u62a4\u710a\u5de5\u827a\u3002<\/p>\n\n  <div class=\"lmac-grid-2\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/strong><br>\u710a\u63a5\u94dc\u7ba1\u65f6\u5fc5\u987b\u5145\u6c2e\u6c14\uff0c\u9632\u6b62\u5185\u58c1\u6c27\u5316\u4ea7\u751f\u710a\u6e23<\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6c2e\u6c14\u4fdd\u538b\u8868\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u6c2e\u6c14\u4fdd\u538b\u8868<\/strong><br>R410A \u7cfb\u7edf\u6253\u538b 4.15MPa\uff0c\u6301\u7eed\u4fdd\u538b\u76d1\u6d4b<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-grid-2col\">\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u94dc\u7ba1\u710a\u63a5\u89c4\u8303<\/h3>\n      <ul>\n        <li>\u4f7f\u7528\u4e13\u7528\u5207\u7ba1\u5668\u5207\u5272\uff0c\u786e\u4fdd\u7aef\u53e3\u5e73\u6574<\/li>\n        <li>\u6269\u53e3\u524d\u5fc5\u987b\u6e05\u9664\u6bdb\u8fb9\u3001\u6bdb\u523a\uff0c\u5c01\u5835\u7ba1\u53e3\u9632\u6b62\u6742\u8d28\u8fdb\u5165<\/li>\n        <li>\u710a\u63a5\u65f6\u5fc5\u987b\u91c7\u7528 <strong>\u6c2e\u6c14\u4fdd\u62a4\u710a<\/strong>\uff08\u6838\u5fc3\uff09<\/li>\n        <li>\u5206\u6b67\u7ba1\u5b89\u88c5\u65b9\u5411\u6b63\u786e\uff0c\u710a\u63a5\u9971\u6ee1\u65e0\u7802\u773c<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u6c14\u5bc6\u6027\u8bd5\u9a8c\u6807\u51c6<\/h3>\n      <ul>\n        <li>R410A \u7cfb\u7edf\u4fdd\u538b <strong>4.15MPa<\/strong><\/li>\n        <li>\u4fdd\u538b\u65f6\u95f4 <strong>24 \u5c0f\u65f6<\/strong>\uff0c\u538b\u529b\u4e0b\u964d 0.01MPa \u4e3a\u5408\u683c<\/li>\n        <li>\u4fdd\u538b\u671f\u95f4\u538b\u529b\u8868\u6301\u7eed\u6302\u538b<\/li>\n        <li>\u4ece\u5b89\u88c5\u5230\u5165\u4f4f\u6301\u7eed\u6302\u538b\uff0c\u6f0f\u70b9\u5373\u65f6\u53d1\u73b0<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-phase1\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u516b<\/span> \u7b2c\u516d\u6b65\uff1a\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536<\/h2>\n  <p class=\"lmac-section-desc\">\u9690\u853d\u5de5\u7a0b\u5c01\u677f\u524d\uff0c\u5b8c\u6210\u6240\u6709\u68c0\u67e5\u5e76\u7b7e\u5b57\u786e\u8ba4\uff0c\u662f\u65bd\u5de5\u8d28\u91cf\u7684\u5173\u952e\u8282\u70b9\u3002<\/p>\n\n  <div class=\"lmac-img-card\" style=\"max-width:600px;margin:0 auto 24px;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\" loading=\"lazy\" style=\"aspect-ratio:4\/3;\">\n    <div class=\"lmac-img-caption\"><strong>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/strong><br>\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u7b7e\u5b57\u786e\u8ba4\uff0c\u5b58\u6863\u5907\u67e5<\/div>\n  <\/div>\n\n  <div class=\"lmac-grid-3col\">\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u8bbe\u5907\u5b89\u88c5\u68c0\u67e5<\/h3>\n      <ul><li>\u5185\u673a\u6c34\u5e73\u5b89\u88c5\u5230\u4f4d<\/li><li>\u68c0\u4fee\u53e3\u9884\u7559\u5408\u89c4<\/li><li>\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\u5b89\u88c5<\/li><li>\u578b\u53f7\u4e0e\u5408\u540c\u4e00\u81f4<\/li><\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u7ba1\u8def\u68c0\u67e5<\/h3>\n      <ul><li>\u94dc\u7ba1\u710a\u63a5\u8d28\u91cf\u5408\u683c<\/li><li>\u4fdd\u6e29\u5b8c\u6574\u65e0\u88f8\u9732<\/li><li>\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u8fbe\u6807<\/li><li>\u6392\u6c34\u8bd5\u9a8c\u901a\u8fc7<\/li><\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u538b\u529b\u8bd5\u9a8c<\/h3>\n      <ul><li>\u6c14\u5bc6\u6027 4.15MPa \u5408\u683c<\/li><li>24 \u5c0f\u65f6\u4fdd\u538b\u5408\u683c<\/li><li>\u538b\u529b\u8868\u6301\u7eed\u6302\u538b<\/li><li>\u9a8c\u6536\u5355\u4e09\u65b9\u7b7e\u5b57<\/li><\/ul>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-norm lmac-norm-gold\">\n    <h3 class=\"lmac-norm-h\">\u8fd9\u4e00\u6b65\u6700\u5bb9\u6613\u51fa\u95ee\u9898\u7684\u5730\u65b9<\/h3>\n    <p>\u5f88\u591a\u5de5\u5730\u662f\"\u88c5\u5b8c\u5c31\u5c01\u677f\uff0c\u5c01\u5b8c\u624d\u60f3\u8d77\u6765\u68c0\u67e5\"\u3002\u9f99\u8109\u6696\u901a\u628a\u9a8c\u6536\u653e\u5728\u5c01\u677f\u524d\uff1a\u94dc\u7ba1\u58c1\u539a\u3001\u710a\u63a5\u8d28\u91cf\u3001\u4fdd\u538b\u6570\u636e\u3001\u51b7\u51dd\u6c34\u5761\u5ea6\uff0c\u4e00\u9879\u9879\u8fc7\u5b8c\u518d\u7b7e\u5b57\u3002\u5c01\u677f\u4e4b\u540e\uff0c\u7ba1\u5b50\u90fd\u5728\u5899\u91cc\u548c\u540a\u9876\u91cc\uff0c\u90a3\u65f6\u5019\u518d\u53d1\u73b0\u95ee\u9898\uff0c\u62c6\u9876\u7684\u6210\u672c\u6bd4\u88c5\u7684\u65f6\u5019\u9ad8\u5f97\u591a\u3002<\/p>\n    <p style=\"font-size:13px;color:var(--lmac-text-lt);\">\u5b8c\u6574\u7684 41 \u6761\u9a8c\u6536\u6807\u51c6\uff0c\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=11380\">\u300a\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\u300b<\/a>\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-commission\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u4e5d<\/span> \u7b2c\u4e03\u6b65\uff1a\u5916\u673a\u62bd\u771f\u7a7a \u00b7 \u7cfb\u7edf\u8c03\u8bd5<\/h2>\n  <p class=\"lmac-section-desc\">\u771f\u7a7a\u5e72\u71e5\u662f\u7cfb\u7edf\u53ef\u9760\u8fd0\u884c\u7684\u524d\u63d0\uff0c\u8c03\u8bd5\u8fd0\u884c\u786e\u4fdd\u5236\u51b7\u5236\u70ed\u6548\u679c\u8fbe\u6807\u3002<\/p>\n\n  <div class=\"lmac-grid-2\">\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b<\/strong><br>\u6c14\u6db2\u4fa7\u540c\u65f6\u62bd\u771f\u7a7a\uff0c\u771f\u7a7a\u5ea6\u8fbe -0.1MPa \u4ee5\u4e0a<\/div>\n    <\/div>\n    <div class=\"lmac-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\" loading=\"lazy\">\n      <div class=\"lmac-img-caption\"><strong>\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/strong><br>\u4f7f\u7528\u7535\u8111\u53ca\u4e13\u4e1a\u8bbe\u5907\u8054\u8c03\uff0c\u751f\u6210\u8fd0\u884c\u62a5\u544a<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-flow\">\n    <div class=\"lmac-flow-step\"><div class=\"lmac-flow-num\">\u2460<\/div><div class=\"lmac-flow-desc\">\u771f\u7a7a\u5e72\u71e5<small>-0.1MPa<\/small><\/div><\/div>\n    <div class=\"lmac-flow-arrow\">\u2192<\/div>\n    <div class=\"lmac-flow-step\"><div class=\"lmac-flow-num\">\u2461<\/div><div class=\"lmac-flow-desc\">\u5236\u51b7\u5242\u8ffd\u52a0<small>\u6db2\u6001 R410A<\/small><\/div><\/div>\n    <div class=\"lmac-flow-arrow\">\u2192<\/div>\n    <div class=\"lmac-flow-step\"><div class=\"lmac-flow-num\">\u2462<\/div><div class=\"lmac-flow-desc\">\u901a\u7535\u8bd5\u8fd0\u884c<small>\u5404\u6a21\u5f0f\u6d4b\u8bd5<\/small><\/div><\/div>\n    <div class=\"lmac-flow-arrow\">\u2192<\/div>\n    <div class=\"lmac-flow-step\"><div class=\"lmac-flow-num\">\u2463<\/div><div class=\"lmac-flow-desc\">\u6027\u80fd\u6d4b\u8bd5<small>\u6e29\u5ea6 \/ \u566a\u97f3<\/small><\/div><\/div>\n    <div class=\"lmac-flow-arrow\">\u2192<\/div>\n    <div class=\"lmac-flow-step\"><div class=\"lmac-flow-num\">\u2464<\/div><div class=\"lmac-flow-desc\">\u8fd0\u884c\u62a5\u544a<small>\u4e09\u65b9\u7b7e\u5b57<\/small><\/div><\/div>\n  <\/div>\n\n  <div class=\"lmac-grid-3col\">\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u771f\u7a7a\u5e72\u71e5<\/h3>\n      <ul><li>\u6c14\u6db2\u4fa7\u540c\u65f6\u62bd\u771f\u7a7a<\/li><li>\u771f\u7a7a\u5ea6\u8fbe\u5230 755mmHg\uff08-0.1MPa\uff09\u4ee5\u4e0a<\/li><li>\u4fdd\u771f\u7a7a \u2265 2 \u5c0f\u65f6\uff0c\u538b\u529b\u65e0\u56de\u5347<\/li><\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u5236\u51b7 \/ \u5236\u70ed\u6d4b\u8bd5<\/h3>\n      <ul><li>\u5404\u623f\u95f4\u9001\u98ce\u6e29\u5ea6\u8fbe\u6807<\/li><li>\u51fa\u98ce\u53e3\u6e29\u5dee 8 \u5ea6\uff08\u5236\u51b7\uff09<\/li><li>\u591a\u53f0\u5185\u673a\u540c\u65f6\u8fd0\u884c\u65e0\u5f02\u5e38<\/li><\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u566a\u97f3\u6d4b\u8bd5<\/h3>\n      <ul><li>\u5ba4\u5185\u673a \/ \u5ba4\u5916\u673a\u566a\u97f3\u5206\u673a\u578b\u3001\u5206\u5185\u673a\u89c4\u683c\u6807\u6ce8\uff0c\u4ee5\u5b98\u65b9\u516c\u5e03\u4e3a\u51c6<\/li><li>\u65e0\u5f02\u5e38\u632f\u52a8\u548c\u5f02\u54cd<\/li><\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-training\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u5341<\/span> \u7b2c\u516b\u6b65\uff1a\u73b0\u573a\u8bbe\u5907\u6559\u5b66 \u00b7 \u5b8c\u7f8e\u4ea4\u4ed8<\/h2>\n  <p class=\"lmac-section-desc\">\u8c03\u8bd5\u5b8c\u6210\u540e\uff0c\u5b89\u88c5\u4eba\u5458\u73b0\u573a\u4e3a\u4e1a\u4e3b\u8bb2\u89e3\u8bbe\u5907\u4f7f\u7528\u529f\u80fd\u4e0e\u65e5\u5e38\u7ef4\u62a4\u6ce8\u610f\u4e8b\u9879\u3002\u8fd9\u662f\u9f99\u8109\u6696\u901a\u4ea4\u4ed8\u670d\u52a1\u7684\u6700\u540e\u4e00\u73af\u3002<\/p>\n\n  <div class=\"lmac-img-card\" style=\"max-width:700px;margin:0 auto 24px;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u73b0\u573a\u8bbe\u5907\u6559\u5b66 - \u9f99\u8109\u6696\u901a\" loading=\"lazy\">\n    <div class=\"lmac-img-caption\"><strong>\u73b0\u573a\u8bbe\u5907\u6559\u5b66<\/strong><br>\u5b89\u88c5\u4eba\u5458\u4e3a\u4e1a\u4e3b\u8bb2\u89e3\u8bbe\u5907\u529f\u80fd\u3001\u7ebf\u63a7\u5668\u64cd\u4f5c\u3001\u65e5\u5e38\u7ef4\u62a4\u4e0e\u6ce8\u610f\u4e8b\u9879<\/div>\n  <\/div>\n\n  <div class=\"lmac-summary-grid\">\n    <div class=\"lmac-summary-card\">\n      <div class=\"lmac-summary-icon\">\ud83d\udcac<\/div>\n      <h4>\u529f\u80fd\u8bb2\u89e3<\/h4>\n      <p>\u7ebf\u63a7\u5668\u64cd\u4f5c\u3001\u6a21\u5f0f\u5207\u6362\u3001\u5b9a\u65f6\u8bbe\u7f6e\u3001\u6e29\u5ea6\u8c03\u8282\u7b49\u65e5\u5e38\u4f7f\u7528\u529f\u80fd\u6f14\u793a<\/p>\n    <\/div>\n    <div class=\"lmac-summary-card\">\n      <div class=\"lmac-summary-icon\">\ud83d\udd27<\/div>\n      <h4>\u7ef4\u62a4\u6307\u5bfc<\/h4>\n      <p>\u8fc7\u6ee4\u7f51\u6e05\u6d17\u5468\u671f\u3001\u5ba4\u5916\u673a\u6563\u70ed\u7a7a\u95f4\u4fdd\u6301\u3001\u5f02\u5e38\u60c5\u51b5\u521d\u6b65\u5224\u65ad<\/p>\n    <\/div>\n    <div class=\"lmac-summary-card\">\n      <div class=\"lmac-summary-icon\">\ud83d\udcde<\/div>\n      <h4>\u552e\u540e\u670d\u52a1<\/h4>\n      <p>\u8d28\u4fdd\u6761\u6b3e\u8bf4\u660e\u3001\u552e\u540e\u670d\u52a1\u70ed\u7ebf\u3001\u540c\u57ce 24 \u5c0f\u65f6\u6545\u969c\u54cd\u5e94\u6d41\u7a0b<\/p>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-safety\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u5341\u4e00<\/span> \u65bd\u5de5\u907f\u5751 \u00b7 \u7535\u6c14\u5b89\u5168<\/h2>\n  <p class=\"lmac-section-desc\">\u6210\u90fd\u672c\u5730\u4e1a\u4e3b\u9ad8\u9891\u5173\u6ce8\u7684\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u95ee\u9898\uff0c\u89c4\u8303\u64cd\u4f5c\u907f\u514d\u540e\u671f\u9690\u60a3\u3002<\/p>\n\n  <div class=\"lmac-grid-2col\">\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u7535\u6c14\u5b89\u5168\u89c4\u8303<\/h3>\n      <ul>\n        <li>\u7535\u6e90\u7ebf\u3001\u901a\u8baf\u7ebf\u538b\u63a5\u63a5\u7ebf\u7aef\u5b50\uff0c\u7edd\u7f18\u80f6\u5e03\u5305\u624e<\/li>\n        <li>\u5fc5\u987b\u914d\u7f6e\u7b26\u5408\u6807\u51c6\u7684\u6f0f\u7535\u4fdd\u62a4\u5668<\/li>\n        <li>\u63a7\u5236\u7ebf\u4e0e\u7535\u6e90\u7ebf\u9694\u79bb\u6577\u8bbe\uff0c\u9632\u6b62\u4fe1\u53f7\u5e72\u6270<\/li>\n        <li>\u5ba4\u5916\u673a\u7535\u6e90\u72ec\u7acb\u56de\u8def\uff0c\u914d\u7f6e\u5408\u9002\u7a7a\u5f00<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u98ce\u53e3\u4e0e\u68c0\u4fee\u53e3\u89c4\u8303<\/h3>\n      <ul>\n        <li><strong>\u98ce\u53e3\u6750\u8d28\uff1a<\/strong>\u63a8\u8350 ABS \u6216\u94dd\u5408\u91d1\u6750\u8d28\u53cc\u767e\u53f6\u98ce\u53e3<\/li>\n        <li><strong>\u706f\u69fd\u5f71\u54cd\uff1a<\/strong>\u4ee5\u5236\u70ed\u4e3a\u4e3b\u65f6\u98ce\u53e3\u4e0e\u706f\u69fd\u9f50\u5e73\u5b89\u88c5\uff0c\u907f\u514d\u963b\u6321\u70ed\u6c14\u6d41<\/li>\n        <li><strong>\u6c14\u6d41\u77ed\u8def\uff1a<\/strong>\u51fa\u98ce\u53e3\u5904\u4e25\u7981\u5236\u4f5c\u77f3\u818f\u7ebf\u3001\u706f\u69fd<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-faq\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u5341\u4e8c<\/span> \u6210\u90fd\u4e1a\u4e3b\u5e38\u89c1\u95ee\u9898<\/h2>\n  <p class=\"lmac-section-desc\">\u56f4\u7ed5\u6210\u90fd\u672c\u5730\u4e1a\u4e3b\u6700\u5173\u5fc3\u7684\u4e2d\u592e\u7a7a\u8c03\u95ee\u9898\uff0c\u9f99\u8109\u6696\u901a\u4e13\u4e1a\u89e3\u7b54\u3002<\/p>\n\n  <div class=\"lmac-faq-item\">\n    <div class=\"lmac-faq-q\"><span>\u6210\u90fd\u88c5\u4fee\uff0c\u4e2d\u592e\u7a7a\u8c03\u4ec0\u4e48\u65f6\u5019\u8fdb\u573a\u5b89\u88c5\u6700\u5408\u9002\uff1f<\/span><span class=\"lmac-faq-icon\">Q<\/span><\/div>\n    <div class=\"lmac-faq-a\">\u4e2d\u592e\u7a7a\u8c03\u5728 <strong>\u6c34\u7535\u6539\u9020\u5b8c\u6210\u540e\u3001\u540a\u9876\u5c01\u677f\u524d<\/strong> \u8fdb\u573a\u5b89\u88c5\uff0c\u4e00\u822c\u662f\u88c5\u4fee\u5f00\u5de5\u540e\u7684 <strong>\u7b2c 2-3 \u5468<\/strong>\u3002\u9f99\u8109\u6696\u901a\u4f1a\u4e3b\u52a8\u4e0e\u88c5\u4fee\u516c\u53f8\u534f\u8c03\u65bd\u5de5\u8282\u70b9\uff0c\u786e\u4fdd\u7ba1\u9053\u94fa\u8bbe\u5b89\u6392\u5728\u540a\u9876\u5de5\u5e8f\u4e4b\u524d\uff0c\u907f\u514d\u8fd4\u5de5\u3002\u5efa\u8bae\u5728<strong>\u88c5\u4fee\u8bbe\u8ba1\u9636\u6bb5\u5c31\u786e\u5b9a\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848<\/strong>\uff0c\u63d0\u524d\u9884\u7559\u98ce\u53e3\u548c\u68c0\u4fee\u53e3\u4f4d\u7f6e\u3002<\/div>\n  <\/div>\n\n  <div class=\"lmac-faq-item\">\n    <div class=\"lmac-faq-q\"><span>\u6210\u90fd\u8001\u623f\u5b50\u3001\u8001\u623f\u7ffb\u65b0\u53ef\u4ee5\u52a0\u88c5\u4e2d\u592e\u7a7a\u8c03\u5417\uff1f<\/span><span class=\"lmac-faq-icon\">Q<\/span><\/div>\n    <div class=\"lmac-faq-a\">\u53ef\u4ee5\u3002\u9700\u8981\u8bc4\u4f30\u5c42\u9ad8\u3001\u6881\u4f4d\u548c\u73b0\u6709\u7535\u8def\u3002\u5982\u679c\u5168\u5c4b\u540a\u9876\u6761\u4ef6\u4e0d\u8db3\uff0c\u53ef\u9009\u62e9 <strong>\u65e5\u7acb\u98ce\u7ba1\u673a\u65b9\u6848<\/strong>\uff08\u5ba2\u9910\u5385\u4e00\u53f0 + \u5367\u5ba4\u58c1\u6302\u673a\uff09\uff0c\u65e0\u9700\u5168\u5c4b\u540a\u9876\u5373\u53ef\u4eab\u53d7\u4e2d\u592e\u7a7a\u8c03\u6548\u679c\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u8bc4\u4f30\u3002<\/div>\n  <\/div>\n\n  <div class=\"lmac-faq-item\">\n    <div class=\"lmac-faq-q\"><span>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u8d28\u4fdd\u591a\u4e45\uff1f\u6f0f\u6c34\u600e\u4e48\u529e\uff1f<\/span><span class=\"lmac-faq-icon\">Q<\/span><\/div>\n    <div class=\"lmac-faq-a\">\u9f99\u8109\u6696\u901a\u63d0\u4f9b\uff1a<strong>\u4e3b\u673a\u8d28\u4fdd 5 \u5e74 + \u7cfb\u7edf\u8d28\u4fdd 2 \u5e74 + \u957f\u671f\u7ef4\u62a4\u670d\u52a1<\/strong>\u3002\u9690\u853d\u5de5\u7a0b\u901a\u8fc7 24 \u5c0f\u65f6\u4fdd\u538b\u6d4b\u8bd5 + \u6ee1\u6c34\u6392\u6c34\u8bd5\u9a8c\u53cc\u91cd\u9a8c\u8bc1\u3002\u51b7\u51dd\u6c34\u7ba1\u4e25\u7981\u63a5\u5165\u6c61\u6c34\u7ba1\u9053\uff0c\u8bbe\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\u4fdd\u6301\u6c14\u538b\u5e73\u8861\u3002\u4e07\u4e00\u51fa\u73b0\u95ee\u9898\uff1a<strong>\u540c\u57ce 24 \u5c0f\u65f6\u552e\u540e\u54cd\u5e94<\/strong>\u3002<\/div>\n  <\/div>\n\n  <div class=\"lmac-faq-item\">\n    <div class=\"lmac-faq-q\"><span>\u4e2d\u592e\u7a7a\u8c03\u5c01\u677f\u4ee5\u540e\u624d\u53d1\u73b0\u95ee\u9898\u600e\u4e48\u529e\uff1f<\/span><span class=\"lmac-faq-icon\">Q<\/span><\/div>\n    <div class=\"lmac-faq-a\">\u8fd9\u6b63\u662f\u628a\u9a8c\u6536\u653e\u5728\u5c01\u677f\u524d\u7684\u539f\u56e0\u3002\u9f99\u8109\u6696\u901a\u5728\u5c01\u677f\u524d\u5b8c\u6210\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\uff0c\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u9010\u9879\u7b7e\u5b57\uff0c\u538b\u529b\u8868\u4ece\u5b89\u88c5\u5230\u5165\u4f4f\u6301\u7eed\u6302\u538b\uff0c\u6f0f\u70b9\u5728\u5c01\u677f\u524d\u5c31\u80fd\u53d1\u73b0\u3002\u5c01\u677f\u4e4b\u540e\u518d\u51fa\u95ee\u9898\uff0c\u62c6\u9876\u7684\u6210\u672c\u6bd4\u88c5\u7684\u65f6\u5019\u9ad8\u5f97\u591a\u3002\u672c\u9875\u6bcf\u4e00\u6b65\u7684\u9a8c\u6536\u6807\u51c6\uff0c\u53e6\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=11380\">\u300a\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\u300b<\/a>\u9010\u6761\u5bf9\u7167\u3002<\/div>\n  <\/div>\n\n  <div class=\"lmac-faq-item\">\n    <div class=\"lmac-faq-q\"><span>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u548c\u5176\u4ed6\u54c1\u724c\u6bd4\uff0c\u672c\u5730\u5b89\u88c5\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f<\/span><span class=\"lmac-faq-icon\">Q<\/span><\/div>\n    <div class=\"lmac-faq-a\">\u65e5\u7acb\u6838\u5fc3\u4f18\u52bf\uff1a<strong>\u6da1\u65cb\u538b\u7f29\u673a\u6280\u672f\u3001\u5168\u76f4\u6d41\u53d8\u9891<\/strong>\uff0c\u9759\u97f3\u6570\u503c\u968f\u673a\u578b\u548c\u5185\u673a\u89c4\u683c\u4e0d\u540c\u5206\u6863\uff08\u4ee5\u5b98\u65b9\u516c\u5e03\u4e3a\u51c6\uff09\u3002\u9f99\u8109\u6696\u901a\u5b89\u88c5\u4f18\u52bf\uff1a<strong>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d<\/strong>\u3001\u539f\u5382\u914d\u4ef6\u76f4\u4f9b\u3001\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6\u65bd\u5de5\uff08\u6c2e\u6c14\u4fdd\u62a4\u710a + 4.15MPa \u4fdd\u538b 24 \u5c0f\u65f6\uff09\u3001\u5168\u7a0b\u53ef\u89c6\u65bd\u5de5\u7167\u7247\u5b9e\u65f6\u53d1\u7fa4\u3001\u4e09\u65b9\u9a8c\u6536\u8d28\u4fdd\u534f\u8bae\u4e00\u5e94\u4ff1\u5168\u3002<\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-trust\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u5341\u4e09<\/span> \u4f01\u4e1a\u8d44\u8d28 \u00b7 \u4fe1\u4efb\u4f50\u8bc1<\/h2>\n  <p class=\"lmac-section-desc\">\u9f99\u8109\u6696\u901a \u00b7 2004 \u5e74\u8d77\u6210\u90fd\u672c\u5730\u6696\u901a\u670d\u52a1\u5546\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u6388\u6743\u7ecf\u9500\u5546\u3002<\/p>\n\n  <div class=\"lmac-summary-grid\">\n    <div class=\"lmac-summary-card\">\n      <div class=\"lmac-summary-icon\">\ud83d\udcdd<\/div>\n      <h4>\u8425\u4e1a\u6267\u7167<\/h4><p>\u6b63\u89c4\u5de5\u5546\u6ce8\u518c\uff0c\u53ef\u67e5\u53ef\u9a8c<\/p>\n    <\/div>\n    <div class=\"lmac-summary-card\">\n      <div class=\"lmac-summary-icon\">\ud83d\udee1<\/div>\n      <h4>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d<\/h4><p>\u5b89\u88c5\u8d44\u8d28\u5206\u7ea7\u4e2d\u7684\u6700\u9ad8\u7b49\u7ea7<\/p>\n    <\/div>\n    <div class=\"lmac-summary-card\">\n      <div class=\"lmac-summary-icon\">\ud83e\udd1d<\/div>\n      <h4>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \/ \u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546<\/h4><p>\u54c1\u724c\u4e0e\u4ea7\u54c1\u7ebf\u6388\u6743\uff0c\u539f\u5382\u914d\u4ef6\u76f4\u4f9b<\/p>\n    <\/div>\n  <\/div>\n\n  <div class=\"lmac-norm lmac-norm-gold\">\n    <h3 class=\"lmac-norm-h\">\u9f99\u8109\u6696\u901a\u6838\u5fc3\u4ef7\u503c<\/h3>\n    <ul>\n      <li><strong>\u6807\u51c6\u7edf\u4e00\uff1a<\/strong>\u4e25\u683c\u8d2f\u5f7b\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6 + \u56fd\u5bb6\u76f8\u5173\u6807\u51c6<\/li>\n      <li><strong>\u8fc7\u7a0b\u900f\u660e\uff1a<\/strong>\u4ece\u5b9a\u4f4d\u5230\u9a8c\u6536\u5168\u7a0b\u62cd\u7167\u53d1\u5ba2\u6237\u7fa4\uff0c\u5173\u952e\u8282\u70b9\u4e09\u65b9\u7b7e\u5b57<\/li>\n      <li><strong>\u7ed3\u679c\u53ef\u9760\uff1a<\/strong>\u6c14\u5bc6\u6027\u8bd5\u9a8c + \u771f\u7a7a\u5e72\u71e5 + \u8fd0\u884c\u8c03\u8bd5\u62a5\u544a\uff0c\u786e\u4fdd\u7cfb\u7edf\u957f\u671f\u7a33\u5b9a\u8fd0\u884c<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<div class=\"lmac-section\" id=\"sec-stores\">\n  <h2 class=\"lmac-section-title\"><span class=\"lmac-section-num\">\u5341\u56db<\/span> \u627e\u9f99\u8109\u6696\u901a<\/h2>\n  <p class=\"lmac-section-desc\">\u53cc\u5b9e\u4f53\u95e8\u5e97\uff0c\u5230\u5e97\u53ef\u67e5\u3001\u53ef\u770b\u5b9e\u673a\u3002\u6709\u95ee\u9898\u76f4\u63a5\u6253\u7535\u8bdd\u3002<\/p>\n\n  <div class=\"lmac-grid-2col\">\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u5357\u5bcc\u68ee\u5e97<\/h3>\n      <ul>\n        <li>\u5730\u5740\uff1a\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<\/li>\n        <li>\u7535\u8bdd\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><\/li>\n        <li>\u8425\u4e1a\uff1a\u5468\u4e00\u81f3\u5468\u4e94 10:00\u201318:00\uff0c\u8282\u5047\u65e5 10:00\u201319:00<\/li>\n        <li><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;query_type=IDQ&amp;query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a\u5230\u5357\u5bcc\u68ee\u5e97<\/a><\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lmac-norm\">\n      <h3 class=\"lmac-norm-h\">\u5317\u5bcc\u68ee\u5e97<\/h3>\n      <ul>\n        <li>\u5730\u5740\uff1a\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135<\/li>\n        <li>\u7535\u8bdd\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><\/li>\n        <li>\u8425\u4e1a\uff1a\u5468\u4e00\u81f3\u5468\u65e5 10:00\u201318:00\uff0c\u8282\u5047\u65e5 10:00\u201319:00<\/li>\n        <li><a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;query_type=IDQ&amp;query=\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a\u5230\u5317\u5bcc\u68ee\u5e97<\/a><\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<\/div>\n\n<div class=\"lmac-footer\">\n  <strong>\u9f99\u8109\u6696\u901a<\/strong> \u00b7 \u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf \u00b7 2004 \u5e74\u8d77<br>\n  \u5357\u5bcc\u68ee\u5e97 028-86131795 \uff5c \u5317\u5bcc\u68ee\u5e97 028-65272586<br>\n  \u672c\u9875\u5185\u5bb9\u4f9d\u636e\u65e5\u7acb\u300a\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303\u300b\u53ca\u56fd\u5bb6\u76f8\u5173\u6807\u51c6\u7f16\u5236 \uff5c \u56fe\u6587\u7d20\u6750\u4e3a\u9f99\u8109\u6696\u901a\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd \u7248\u6743\u6240\u6709\n<\/div>\n\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u5168\u8fc7\u7a0b \u00b7 \u9f99\u8109\u6696\u901a\u516b\u6b65 [&hellip;]<\/p>\n","protected":false},"author":16,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6342","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u516b\u6b65\u65bd\u5de5\u6d41\u7a0b\uff1a\u52d8\u6d4b\u8bbe\u8ba1\u3001\u6750\u6599\u9a8c\u6536\u3001\u5185\u673a\u5b89\u88c5\u3001\u51b7\u51dd\u6c34\u3001\u94dc\u7ba1\u710a\u63a5\u4fdd\u538b\u3001\u9690\u853d\u9a8c\u6536\u3001\u62bd\u771f\u7a7a\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66\u3002\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5e97\uff0c028-86131795+028-65272586\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=6342\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u516b\u6b65\u65bd\u5de5\u6d41\u7a0b\uff1a\u52d8\u6d4b\u8bbe\u8ba1\u3001\u6750\u6599\u9a8c\u6536\u3001\u5185\u673a\u5b89\u88c5\u3001\u51b7\u51dd\u6c34\u3001\u94dc\u7ba1\u710a\u63a5\u4fdd\u538b\u3001\u9690\u853d\u9a8c\u6536\u3001\u62bd\u771f\u7a7a\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66\u3002\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5e97\uff0c028-86131795+028-65272586\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=6342\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-21T06:28:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342\",\"name\":\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg\",\"datePublished\":\"2026-07-12T14:49:33+00:00\",\"dateModified\":\"2026-10-21T06:28:42+00:00\",\"description\":\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u516b\u6b65\u65bd\u5de5\u6d41\u7a0b\uff1a\u52d8\u6d4b\u8bbe\u8ba1\u3001\u6750\u6599\u9a8c\u6536\u3001\u5185\u673a\u5b89\u88c5\u3001\u51b7\u51dd\u6c34\u3001\u94dc\u7ba1\u710a\u63a5\u4fdd\u538b\u3001\u9690\u853d\u9a8c\u6536\u3001\u62bd\u771f\u7a7a\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66\u3002\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5e97\uff0c028-86131795+028-65272586\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6342#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u516b\u6b65\u65bd\u5de5\u6d41\u7a0b\uff1a\u52d8\u6d4b\u8bbe\u8ba1\u3001\u6750\u6599\u9a8c\u6536\u3001\u5185\u673a\u5b89\u88c5\u3001\u51b7\u51dd\u6c34\u3001\u94dc\u7ba1\u710a\u63a5\u4fdd\u538b\u3001\u9690\u853d\u9a8c\u6536\u3001\u62bd\u771f\u7a7a\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66\u3002\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5e97\uff0c028-86131795+028-65272586\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=6342","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u516b\u6b65\u65bd\u5de5\u6d41\u7a0b\uff1a\u52d8\u6d4b\u8bbe\u8ba1\u3001\u6750\u6599\u9a8c\u6536\u3001\u5185\u673a\u5b89\u88c5\u3001\u51b7\u51dd\u6c34\u3001\u94dc\u7ba1\u710a\u63a5\u4fdd\u538b\u3001\u9690\u853d\u9a8c\u6536\u3001\u62bd\u771f\u7a7a\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66\u3002\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5e97\uff0c028-86131795+028-65272586\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=6342","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-21T06:28:42+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=6342","url":"https:\/\/longmai-nt.com\/?page_id=6342","name":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=6342#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=6342#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg","datePublished":"2026-07-12T14:49:33+00:00","dateModified":"2026-10-21T06:28:42+00:00","description":"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u516b\u6b65\u65bd\u5de5\u6d41\u7a0b\uff1a\u52d8\u6d4b\u8bbe\u8ba1\u3001\u6750\u6599\u9a8c\u6536\u3001\u5185\u673a\u5b89\u88c5\u3001\u51b7\u51dd\u6c34\u3001\u94dc\u7ba1\u710a\u63a5\u4fdd\u538b\u3001\u9690\u853d\u9a8c\u6536\u3001\u62bd\u771f\u7a7a\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66\u3002\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d\u3001\u65e5\u7acb\uff0f\u6c34\u5885\u9002\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5e97\uff0c028-86131795+028-65272586\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=6342#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=6342"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=6342#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=6342#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303 \u00b7 \u5168\u7a0b\u53ef\u89c6\u5316\u670d\u52a1\u6807\u51c6"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6342","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6342"}],"version-history":[{"count":12,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6342\/revisions"}],"predecessor-version":[{"id":15888,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6342\/revisions\/15888"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6342"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}