{"id":660,"date":"2026-05-13T16:39:46","date_gmt":"2026-05-13T08:39:46","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=660"},"modified":"2026-05-22T12:22:29","modified_gmt":"2026-05-22T04:22:29","slug":"%e6%8c%87%e4%bb%a41%ef%bc%9a%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a%c2%b7%e8%ae%be%e8%ae%a1%e8%a7%84%e8%8c%83%e4%b8%8e%e5%ae%a2%e6%88%b7%e7%9f%a5%e8%af%86","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=660","title":{"rendered":"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><em>\u7248\u672c\uff1aV5.0<\/em><br><em>\u66f4\u65b0\u65e5\u671f\uff1a2026\u5e745\u670821\u65e5<\/em><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"\u76ee\u5f55\" class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl101\">\u4e00\u3001\u6307\u4ee4\u76ee\u6807<\/a><\/li>\n\n\n\n<li><a href=\"#zl102\">\u4e8c\u3001\u9002\u7528\u573a\u666f<\/a><\/li>\n\n\n\n<li><a href=\"#zl103\">\u4e09\u3001\u5b89\u5168\u9ed8\u8ba4\u503c<\/a><\/li>\n\n\n\n<li><a href=\"#zl104\">\u56db\u3001\u6838\u5fc3\u89c4\u5219<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl1041\">4.1 \u8bbe\u8ba1\u7406\u5ff5\u6838\u5fc3<\/a><\/li>\n\n\n\n<li><a href=\"#zl1042\">4.2 \u521a\u6027\u8bbe\u8ba1\u7ea2\u7ebf\uff08\u517113\u6761\uff09<\/a><\/li>\n\n\n\n<li><a href=\"#zl1043\">4.3 \u62a5\u8b66\u89e6\u53d1\u6761\u4ef6<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#zl105\">\u4e94\u3001\u6267\u884c\u6b65\u9aa4<\/a><\/li>\n\n\n\n<li><a href=\"#zl106\">\u516d\u3001\u9a8c\u8bc1\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl107\">\u4e03\u3001\u7981\u6b62\u884c\u4e3a<\/a><\/li>\n\n\n\n<li><a href=\"#zl108\">\u516b\u3001\u5e38\u89c1\u9519\u8bef<\/a><\/li>\n\n\n\n<li><a href=\"#zl109\">\u4e5d\u3001\u5173\u8054\u77e5\u8bc6\u5e93<\/a><\/li>\n\n\n\n<li><a href=\"#zl1f0\">\u9644\u5f55\u96f6\uff1a\u77e5\u8bc6\u68c0\u7d22\u8def\u5f84\u603b\u8868<\/a><\/li>\n\n\n\n<li><a href=\"#zl1f1\">\u9644\u5f55\u4e00\uff1a\u5927\u767d\u8bdd\u7c7b\u6bd4\u5e93<\/a><\/li>\n\n\n\n<li><a href=\"#zl1f2\">\u9644\u5f55\u4e8c\uff1a\u914d\u7f6e\u8bca\u65ad\u4e0e\u8d85\u914d\u81ea\u67e5\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl1f3\">\u9644\u5f55\u4e09\uff1a\u6807\u51c6\u5316\u6280\u672f\u8def\u5f84\u8868<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl101\" class=\"wp-block-heading\">\u4e00\u3001\u6307\u4ee4\u76ee\u6807<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3aDS\u65b9\u6848\u8bbe\u8ba1\u63d0\u4f9b\u5fc5\u987b\u9075\u5b88\u7684\u6280\u672f\u89c4\u8303\u3001\u8bbe\u8ba1\u7ea2\u7ebf\u548c\u62a5\u8b66\u6761\u4ef6\u3002\u5b9a\u4f4d\uff1a\u65b9\u6848\u8bbe\u8ba1\u7684\u6280\u672f\u5baa\u6cd5\u2014\u2014\u4e0d\u662f\u4ec0\u4e48\u90fd\u80fd\u505a\uff0c\u53ea\u80fd\u5728\u8fd9\u4e9b\u89c4\u5219\u5185\u505a\u3002\u8be6\u7ec6\u6280\u672f\u539f\u7406\u3001\u56fd\u6807\u539f\u6587\u3001\u6848\u4f8b\u5185\u5bb9\u4e0d\u5b58\u4e8e\u672c\u6307\u4ee4\uff0c\u6309\u9644\u5f55\u96f6\u7684\u68c0\u7d22\u8def\u5f84\u6309\u9700\u67e5\u8be2\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl102\" class=\"wp-block-heading\">\u4e8c\u3001\u9002\u7528\u573a\u666f<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DS\u677f\u5757\u4e00\u8bca\u65ad\u5206\u6790\uff1a\u67e5\u75c5\u56e0\u5bf9\u5e94\u7684\u6280\u672f\u539f\u7406\uff08\u901a\u8fc7\u9644\u5f55\u96f6\u68c0\u7d22\u767d\u76ae\u4e66\uff09<\/li>\n\n\n\n<li>DS\u677f\u5757\u4e8c\u65b9\u6848\u8bbe\u8ba1\uff1a\u9010\u6761\u5bf9\u7167\u8bbe\u8ba1\u7ea2\u7ebf\u3001\u626b\u63cf\u62a5\u8b66\u6761\u4ef6<\/li>\n\n\n\n<li>DS\u677f\u5757\u4e09\u914d\u7f6e\u6e05\u5355\u8f93\u51fa\u524d\uff1a\u6267\u884c\u9644\u5f55\u4e8c\u7684\u914d\u7f6e\u8bca\u65ad\u4e0e\u8d85\u914d\u81ea\u67e5<\/li>\n\n\n\n<li>\u5ba2\u6237\u8ffd\u95ee\u6280\u672f\u7ec6\u8282\u65f6\uff1a\u8c03\u7528\u9644\u5f55\u4e00\u7684\u5927\u767d\u8bdd\u7c7b\u6bd4\u5e93\u7ffb\u8bd1<\/li>\n\n\n\n<li>\u6d89\u53ca\u51fa\u98ce\u8212\u9002\u6027\u7b49\u6280\u672f\u8def\u5f84\u9009\u62e9\u65f6\uff1a\u67e5\u9605\u9644\u5f55\u4e09\u7684\u6807\u51c6\u5316\u6280\u672f\u8def\u5f84\u8868<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl103\" class=\"wp-block-heading\">\u4e09\u3001\u5b89\u5168\u9ed8\u8ba4\u503c<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4efb\u4f55\u8bbe\u8ba1\u89e6\u78b0\u62a5\u8b66\u6761\u4ef6\uff1a\u5fc5\u987b\u63d0\u793a\u9500\u552e\uff0c\u4e0d\u5f97\u9759\u9ed8\u901a\u8fc7<\/li>\n\n\n\n<li>\u5f15\u7528\u56fd\u6807\u7f16\u53f7\u5fc5\u987b\u53ef\u9a8c\u8bc1\uff08\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf\u53ef\u67e5\uff09<\/li>\n\n\n\n<li>\u6280\u672f\u53c2\u6570\u4e0d\u786e\u5b9a\uff1a\u6807\u6ce8\u300c\u5f85\u52d8\u6d4b\u786e\u8ba4\u300d\uff0c\u7981\u6b62\u5047\u8bbe<\/li>\n\n\n\n<li>\u65b9\u6848\u8bbe\u8ba1\u4ece\u5b89\u5168\u7b2c\u4e00\u5c42\u5f00\u59cb\uff0c\u9010\u5c42\u5411\u4e0a\uff0c\u4e0d\u53ef\u8df3\u8fc7<\/li>\n\n\n\n<li>\u75c5\u56e0\u5224\u65ad\u4e0d\u786e\u5b9a\u65f6\uff1a\u5148\u901a\u8fc7\u9644\u5f55\u96f6\u68c0\u7d22\u767d\u76ae\u4e66\uff0c\u7981\u6b62\u51ed\u5e38\u8bc6\u4e0b\u7ed3\u8bba\uff0c\u4f18\u5148\u68c0\u7d22\u300a\u5b9e\u6218\u624b\u518c\u300b\u7b2c\u4e09\u7bc7\u300c\u7528\u6237\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790\u300d\u3002<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl104\" class=\"wp-block-heading\">\u56db\u3001\u6838\u5fc3\u89c4\u5219<\/h2>\n\n\n\n<h3 id=\"zl1041\" class=\"wp-block-heading\">4.1 \u8bbe\u8ba1\u7406\u5ff5\u6838\u5fc3<\/h3>\n\n\n\n<h4 id=\"411-\u7cfb\u7edf\u8bbe\u8ba1\u56db\u8981\u7d20\" class=\"wp-block-heading\">4.1.1 \u7cfb\u7edf\u8bbe\u8ba1\u56db\u8981\u7d20<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u6240\u6709\u6696\u901a\u7cfb\u7edf\u7531\u56db\u8981\u7d20\u6784\u6210\uff0c\u7f3a\u4e00\u4e0d\u53ef\u3002\u8bbe\u8ba1\u5fc5\u987b\u5728\u56db\u8981\u7d20\u4e4b\u95f4\u627e\u5230\u5e73\u8861\u2014\u2014\u67d0\u4e00\u9879\u8fc7\u5ea6\u914d\u7f6e\u5c31\u662f\u7cfb\u7edf\u5931\u8861\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u8981\u7d20<\/th><th>\u804c\u8d23<\/th><th>\u9009\u578b\u539f\u5219<\/th><\/tr><\/thead><tbody><tr><td>\u70ed\u6e90<\/td><td>\u4ea7\u751f\u51b7\/\u70ed\u91cf<\/td><td>\u6700\u5c0f\u8f93\u51fa\u529f\u7387 \u2264 \u623f\u95f4\u6052\u6e29\u8d1f\u8377\uff0c\u5426\u5219\u9891\u7e41\u542f\u505c<\/td><\/tr><tr><td>\u8f93\u914d<\/td><td>\u8f93\u9001\u51b7\/\u70ed\u91cf<\/td><td>\u7ba1\u5f84\u51b3\u5b9a\u6d41\u91cf\uff0c\u6d41\u91cf\u51b3\u5b9a\u6548\u679c\u3002\u7981\u6b62\u5c0f\u7ba1\u5f84\u5927\u8d1f\u8377<\/td><\/tr><tr><td>\u672b\u7aef<\/td><td>\u91ca\u653e\u51b7\/\u70ed\u91cf<\/td><td>\u6563\u70ed\u80fd\u529b\u5fc5\u987b \u2265 \u623f\u95f4\u70ed\u8d1f\u8377<\/td><\/tr><tr><td>\u63a7\u5236<\/td><td>\u8c03\u5ea6\u8fd0\u884c<\/td><td>\u5fc5\u987b\u6709\u5ba4\u6e29\u8054\u52a8\uff0c\u7981\u6b62\u4ec5\u9760\u6c34\u6e29\u542f\u505c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"412-\u5236\u51b7\u5236\u70ed\u5206\u79bb\u7406\u5ff5\" class=\"wp-block-heading\">4.1.2 \u5236\u51b7\u5236\u70ed\u5206\u79bb\u7406\u5ff5<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u5236\u51b7\u548c\u5236\u70ed\u662f\u4e24\u79cd\u5b8c\u5168\u4e0d\u540c\u7684\u7269\u7406\u8fc7\u7a0b\uff0c\u5bf9\u7cfb\u7edf\u8bbe\u8ba1\u7684\u8981\u6c42\u4e0d\u540c\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5236\u51b7\u6838\u5fc3\u77db\u76fe<\/strong>\uff1a\u51fa\u98ce\u6e29\u5ea6\u4e0e\u9664\u6e7f\u7684\u5e73\u8861\u3002\u6c1f\u673a\u51fa\u98ce\u53e37-12\u2103\uff0c\u76f4\u5439\u4eba\u4f53\u4e0d\u9002\u3002\u89e3\u51b3\u8def\u5f84\u6709\u56db\u6761\uff1a\u53d8\u51b7\u5a92\u6d41\u91cf\u63d0\u5347\u84b8\u53d1\u6e29\u5ea6\u3001\u9ad8\u663e\u70ed\u6a21\u5f0f\u964d\u4f4e\u9664\u6e7f\u6bd4\u4f8b\u3001\u4e09\u7ba1\u5236\u53cc\u6362\u70ed\u56de\u6536\u4f59\u70ed\u3001\u6c34\u7cfb\u7edf\u4e8c\u6b21\u6362\u70ed\u3002\u56db\u6761\u8def\u5f84\u4ece\u8212\u4eab\u5230\u6c34\u5885\u9002\u5747\u53ef\u5b9e\u73b0\uff0c\u8be6\u89c1\u9644\u5f55\u4e09\u3002<\/li>\n\n\n\n<li><strong>\u5236\u70ed\u6838\u5fc3\u77db\u76fe<\/strong>\uff1a\u70ed\u6e90\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u4e0e\u623f\u95f4\u6052\u6e29\u8d1f\u8377\u7684\u5339\u914d\u3002\u5c0f\u6237\u578b\uff08\u226480\u33a1\uff09\u6052\u6e29\u8d1f\u8377\u4ec52-3kW\uff0c\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa8-10kW \u2192 \u5fc5\u7136\u9891\u7e41\u542f\u505c\u3002\u6b64\u7c7b\u573a\u666f\u5fc5\u987b\u63a8\u8350\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa3-4kW\uff09\u6216\u5206\u6bb5\u71c3\u70e7\u7089\u3002<\/li>\n\n\n\n<li><strong>\u5236\u51b7\u548c\u5236\u70ed\u4e0d\u5e94\u7ed1\u5728\u540c\u4e00\u5957\u903b\u8f91\u91cc\u9009\u578b<\/strong>\u3002\u5236\u51b7\u770b\u91cd\u5feb\u901f\u54cd\u5e94\u548c\u51fa\u98ce\u54c1\u8d28\uff0c\u5236\u70ed\u770b\u91cd\u4f4e\u9891\u5339\u914d\u548c\u6301\u7eed\u7a33\u5b9a\u3002<\/li>\n<\/ul>\n\n\n\n<h4 id=\"413-\u7a7a\u8c03\u9009\u578b\u4e09\u6b65\u6cd5\" class=\"wp-block-heading\">4.1.3 \u7a7a\u8c03\u9009\u578b\u4e09\u6b65\u6cd5<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u5b9a\u9700\u6c42<\/strong>\uff1a\u5236\u51b7\u4e3a\u4e3b\u8fd8\u662f\u51b7\u6696\u5e76\u91cd\uff1f\u5bf9\u51fa\u98ce\u6e29\u5ea6\u654f\u611f\u8fd8\u662f\u5bf9\u54cd\u5e94\u901f\u5ea6\u654f\u611f\uff1f<\/li>\n\n\n\n<li><strong>\u5b9a\u7cfb\u7edf<\/strong>\uff1a\u6c1f\u7cfb\u7edf\uff08\u54cd\u5e94\u5feb\u3001\u6280\u672f\u6210\u719f\uff09\u8fd8\u662f\u6c34\u7cfb\u7edf\uff08\u51fa\u98ce\u67d4\u548c\u3001\u8212\u9002\u5ea6\u9ad8\uff09\uff1f<\/li>\n\n\n\n<li><strong>\u5b9a\u8bbe\u5907<\/strong>\uff1a\u6839\u636e\u623f\u95f4\u6570\u3001\u9762\u79ef\u3001\u540c\u5f00\u7387\u5339\u914d\u5185\u5916\u673a\uff0c\u8d85\u914d\u7387\u63a7\u5236\u5728\u5408\u7406\u533a\u95f4\u3002<\/li>\n<\/ol>\n\n\n\n<h4 id=\"414-\u9700\u6c42\u5c42\u6b21\u7406\u8bba\" class=\"wp-block-heading\">4.1.4 \u9700\u6c42\u5c42\u6b21\u7406\u8bba<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u8bbe\u8ba1\u5fc5\u987b\u81ea\u4e0b\u800c\u4e0a\u9010\u5c42\u6ee1\u8db3\u3002\u5b89\u5168\u5c42\u672a\u6ee1\u8db3\uff0c\u4e0d\u5f97\u8df3\u5230\u8212\u9002\u5c42\u3002\u5b8c\u6574\u9610\u8ff0\u8be6\u89c1\u5baa\u6cd5V6.0\u7b2c\u4e09\u7ae0\u300c\u80fd\u91cf\u7ba1\u7406\u300d\u3002<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5ba2\u6237\u6210\u529f \u2192 \u5b89\u5168 \u2192 \u57fa\u7840\u51b7\u6696 \u2192 \u5065\u5eb7\u8212\u9002 \u2192 \u8282\u80fd\u7701\u5fc3 \u2192 \u4e2a\u6027\u7f8e\u5b66 \u2192 \u957f\u671f\u4e3b\u4e49\u9a8c\u8bc1<\/p>\n<\/blockquote>\n\n\n\n<h4 id=\"415-\u70ed\u8d1f\u8377\u539f\u7406\u5f15\u7528\u5165\u53e3\" class=\"wp-block-heading\">4.1.5 \u70ed\u8d1f\u8377\u539f\u7406\uff08\u5f15\u7528\u5165\u53e3\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u70ed\u8d1f\u8377\u8ba1\u7b97\u516c\u5f0f\u548c\u5b8c\u6574\u63a8\u5bfc\u8fc7\u7a0b\uff0c\u8be6\u89c1\u300a\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66\u300b\u7b2c\u56db\u7ae0\u3002\u6210\u90fd\u5730\u533a\uff08\u590f\u70ed\u51ac\u51b7\uff09\u6309GB50736-2012\u6807\u51c6\uff1a\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u837750-80W\/\u33a1\uff0c\u5236\u51b7\u8d1f\u8377\u53c2\u7167\u540c\u6807\u51c6\u6267\u884c\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 id=\"zl1042\" class=\"wp-block-heading\">4.2 \u521a\u6027\u8bbe\u8ba1\u7ea2\u7ebf\uff08\u517113\u6761\uff09<\/h3>\n\n\n\n<h4 id=\"\u901a\u7528\u7ea2\u7ebf6\u6761\" class=\"wp-block-heading\">\u901a\u7528\u7ea2\u7ebf\uff086\u6761\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>#<\/th><th>\u7ea2\u7ebf<\/th><th>\u8fdd\u53cd\u540e\u679c<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>\u8d85\u914d\u7387\u2014\u2014\u6c1f\u7cfb\u7edf50%-130%\uff08\u7406\u60f390%-110%\uff09\uff1b\u6c34\u7cfb\u7edf\u53ef\u8d85200%\uff08\u7406\u60f3120%-180%\uff09<\/td><td>\u8d85\u914d\u7387\u8fc7\u9ad8 = \u9891\u7e41\u542f\u505c + \u9ad8\u80fd\u8017<\/td><\/tr><tr><td>2<\/td><td>\u5185\u673a\u5fc5\u987b\u642d\u914d\u540c\u7cfb\u5217\u5916\u673a\uff0c\u4e0d\u53ef\u6df7\u7528\uff08\u4e09\u7ba1\u5236\u5185\u673a\u4ec5\u914d\u5c0a\u777f\u5168\u6548\u5916\u673a\uff09<\/td><td>\u6df7\u7528 = \u529f\u80fd\u5931\u6548<\/td><\/tr><tr><td>3<\/td><td>\u5236\u51b7\u8d1f\u8377\u6309GB50736-2012\u6807\u51c6\uff0c\u6210\u90fd\u5730\u533a50-80W\/\u33a1<\/td><td>\u7b97\u9519 = \u51b7\u91cf\u4e0d\u591f\u6216\u8fc7\u5ea6\u914d\u7f6e<\/td><\/tr><tr><td>4<\/td><td>\u91c7\u6696\u4e0e\u70ed\u6c34\u5fc5\u987b\u5206\u79bb\u8bbe\u8ba1\uff0c\u7981\u6b62\u5171\u7528\u70ed\u6e90<\/td><td>\u5171\u7528 = \u51ac\u5929\u6d17\u6fa1\u6c34\u6e29\u5ffd\u51b7\u5ffd\u70ed<\/td><\/tr><tr><td>5<\/td><td>\u70ed\u6c34\u7cfb\u7edf\u7981\u6b62\u51b7\u70ed\u6c34\u7ba1\u63a5\u901a<\/td><td>\u4e32\u6d41 = \u8bbe\u5907\u635f\u574f<\/td><\/tr><tr><td>6<\/td><td>\u6696\u6c14\u7247\u7ba1\u6750\u6807\u914d\u94dd\u5851\u590d\u5408\u7ba1\uff0c\u7981\u6b62\u8868\u8ff0\u4e3a\u300c\u5347\u7ea7\u914d\u7f6e\u300d<\/td><td>\u8bef\u5bfc\u5ba2\u6237<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"\u6c34\u7cfb\u7edf\u4e13\u5c5e\u7ea2\u7ebf7\u6761\" class=\"wp-block-heading\">\u6c34\u7cfb\u7edf\u4e13\u5c5e\u7ea2\u7ebf\uff087\u6761\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>#<\/th><th>\u7ea2\u7ebf<\/th><th>\u8fdd\u53cd\u540e\u679c<\/th><\/tr><\/thead><tbody><tr><td>7<\/td><td>\u6c34\u7cfb\u7edf\u4f18\u5148\u91c7\u7528\u4e00\u6b21\u7cfb\u7edf\uff08\u7b80\u5355\u53ef\u9760\uff09<\/td><td>\u4e8c\u6b21\u7cfb\u7edf\u589e\u52a0\u6545\u969c\u70b9<\/td><\/tr><tr><td>8<\/td><td>\u5fc5\u987b\u914d\u7f6e\u7f13\u51b2\u6c34\u7bb1<\/td><td>\u65e0\u6c34\u7bb1 = \u9891\u7e41\u542f\u505c + \u538b\u7f29\u673a\u77ed\u547d<\/td><\/tr><tr><td>9<\/td><td>PPR\u7ba1\u58c1\u539a\uff1a\u4e3b\u7ba1\u22654.2mm\uff0c\u652f\u7ba1\u22653.5mm<\/td><td>\u58c1\u539a\u4e0d\u8db3 = \u7206\u7ba1\u98ce\u9669<\/td><\/tr><tr><td>10<\/td><td>\u76d8\u7ba1\u7ba1\u5f84\u2265De20\uff0c\u4e0d\u53ef\u7f29\u5c0f<\/td><td>\u7ba1\u5f84\u4e0d\u8db3 = \u672b\u7aef\u4e0d\u70ed<\/td><\/tr><tr><td>11<\/td><td>\u6c34\u6cf5\u5fc5\u987b\u4e0e\u4e3b\u673a\u8054\u52a8\u63a7\u5236<\/td><td>\u6c34\u6cf5\u5e38\u8f6c = \u65e0\u6548\u8017\u7535<\/td><\/tr><tr><td>12<\/td><td>\u98ce\u76d8\u9009\u578b\u5fc5\u987b\u5339\u914d\u6c34\u7cfb\u7edf\u4f9b\u6c34\u6e29\u5ea6<\/td><td>\u4e0d\u5339\u914d = \u51b7\u4e0d\u4e0b\u6765\u6216\u7ed3\u9732<\/td><\/tr><tr><td>13<\/td><td>\u963b\u6c27\u7ba1\/\u963b\u6c27\u5c42\u5fc5\u987b\u7edf\u4e00\uff0c\u4e0d\u53ef\u5c40\u90e8\u7701\u7565<\/td><td>\u5c40\u90e8\u7701\u7565 = \u5168\u6bb5\u6027\u80fd\u88ab\u77ed\u677f\u62c9\u4f4e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"\u70ed\u6e90\u9009\u578b\u8865\u5145\u7ea2\u7ebf\" class=\"wp-block-heading\">\u70ed\u6e90\u9009\u578b\u8865\u5145\u7ea2\u7ebf<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u300c\u6700\u63a5\u8fd1\u300d\u539f\u5219<\/strong>\uff1a\u9505\u7089\u989d\u5b9a\u529f\u7387\u9009\u62e9\u6700\u63a5\u8fd1\uff08\u4e0d\u8d85\u8fc7120%\uff09\u8bbe\u8ba1\u70ed\u8d1f\u8377\u7684\u578b\u53f7\u3002\u7981\u6b62\u4e60\u60ef\u6027\u9009\u5927\u3002<\/li>\n\n\n\n<li><strong>\u5c0f\u6237\u578b\u7279\u522b\u8b66\u544a<\/strong>\uff1a60-80\u33a1\u91c7\u6696\u9762\u79ef\uff0c\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa8-10kW\u8fdc\u8d85\u6052\u6e29\u8d1f\u83772-3kW\uff0c\u5fc5\u7136\u9891\u7e41\u542f\u505c\u3002\u5fc5\u987b\u63a8\u8350\u51b7\u51dd\u7089\u6216\u5206\u6bb5\u71c3\u70e7\u7089\u3002<\/li>\n\n\n\n<li><strong>\u51b7\u51dd\u7089\u4f4e\u6e29\u7ba1\u9053\u8981\u6c42<\/strong>\uff1a\u4f9b\u6c34\u6e29\u5ea6\u5b9c35-45\u2103\uff0c\u7ba1\u9053\u53ca\u672b\u7aef\u5fc5\u987b\u6821\u6838\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u80fd\u529b\u3002\u4f9b\u6c34\u6e29\u5ea6\u8d8550\u2103\u65f6\u51b7\u51dd\u6548\u679c\u9aa4\u964d\u3002<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 id=\"zl1043\" class=\"wp-block-heading\">4.3 \u62a5\u8b66\u89e6\u53d1\u6761\u4ef6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4efb\u4e00\u6761\u89e6\u53d1\u65f6\uff0cDS\u5fc5\u987b\u63d0\u793a\u9500\u552e\uff0c\u4e0d\u5f97\u9759\u9ed8\u901a\u8fc7\u3002<\/p>\n\n\n\n<h4 id=\"\u901a\u7528\u62a5\u8b666\u6761\" class=\"wp-block-heading\">\u901a\u7528\u62a5\u8b66\uff086\u6761\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>#<\/th><th>\u89e6\u53d1\u6761\u4ef6<\/th><\/tr><\/thead><tbody><tr><td>A1<\/td><td>\u8d85\u914d\u7387\u8d8a\u754c\uff08\u6c1f\u7cfb\u7edf\u8d85\u8fc7130%\u6216\u6c34\u7cfb\u7edf\u8d85\u8fc7200%\uff09<\/td><\/tr><tr><td>A2<\/td><td>\u5236\u70ed\u914d\u7f6e\u9519\u8bef\uff08\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387 &gt; \u623f\u95f4\u6052\u6e29\u8d1f\u8377\u76842\u500d\uff09<\/td><\/tr><tr><td>A3<\/td><td>\u4e3b\u7ba1\u7ba1\u5f84\u4e0e\u9762\u79ef\u4e0d\u5339\u914d\uff08\u2265100\u33a1\u5374\u7528De25\u4e3b\u7ba1\uff09<\/td><\/tr><tr><td>A4<\/td><td>\u65e0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff08\u4ec5\u9760\u6c34\u6e29\u542f\u505c\u6216\u624b\u52a8\u63a7\u5236\uff09<\/td><\/tr><tr><td>A5<\/td><td>\u70ed\u6e90\u529f\u7387\u8fdc\u8d85\u8bbe\u8ba1\u70ed\u8d1f\u8377\uff08\u8d85\u8fc7120%\uff09<\/td><\/tr><tr><td>A6<\/td><td>\u51b7\u51dd\u7089\u7cfb\u7edf\u4f9b\u6c34\u6e29\u5ea6\u8bbe\u5b9a\u8d85\u8fc750\u2103<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"\u6c34\u7cfb\u7edf\u62a5\u8b666\u6761\" class=\"wp-block-heading\">\u6c34\u7cfb\u7edf\u62a5\u8b66\uff086\u6761\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>#<\/th><th>\u89e6\u53d1\u6761\u4ef6<\/th><\/tr><\/thead><tbody><tr><td>B1<\/td><td>\u6c34\u7cfb\u7edf\u672a\u914d\u7f6e\u7f13\u51b2\u6c34\u7bb1<\/td><\/tr><tr><td>B2<\/td><td>\u6c34\u6cf5\u672a\u4e0e\u4e3b\u673a\u8054\u52a8<\/td><\/tr><tr><td>B3<\/td><td>\u98ce\u76d8\u9009\u578b\u672a\u6821\u6838\u6c34\u7cfb\u7edf\u4f9b\u6c34\u6e29\u5ea6<\/td><\/tr><tr><td>B4<\/td><td>\u76d8\u7ba1\u7ba1\u5f84\uff1cDe20<\/td><\/tr><tr><td>B5<\/td><td>\u963b\u6c27\u7ba1\/\u963b\u6c27\u5c42\u5c40\u90e8\u7701\u7565<\/td><\/tr><tr><td>B6<\/td><td>PPR\u7ba1\u58c1\u539a\u4e0d\u8fbe\u6807<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"\u70ed\u6e90\u9009\u578b\u62a5\u8b665\u6761\" class=\"wp-block-heading\">\u70ed\u6e90\u9009\u578b\u62a5\u8b66\uff085\u6761\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>#<\/th><th>\u89e6\u53d1\u6761\u4ef6<\/th><\/tr><\/thead><tbody><tr><td>C1<\/td><td>\u91c7\u6696\u9762\u79ef\u226480\u33a1\u63a8\u8350\u4e86\u666e\u901a\u7089\uff08\u6700\u5c0f\u8f93\u51fa8-10kW\uff09<\/td><\/tr><tr><td>C2<\/td><td>\u91c7\u6696\u9762\u79ef\u226480\u33a1\u51b7\u51dd\u7089\u672a\u6821\u6838\u4f4e\u6e29\u4f9b\u6c34\u672b\u7aef\u6563\u70ed\u80fd\u529b<\/td><\/tr><tr><td>C3<\/td><td>\u91c7\u6696\u4e0e\u70ed\u6c34\u5171\u7528\u70ed\u6e90\u4e14\u65e0\u4e13\u95e8\u7cfb\u7edf\u8bbe\u8ba1<\/td><\/tr><tr><td>C4<\/td><td>\u9505\u7089\u9009\u578b\u529f\u7387\u8d85\u8fc7\u8bbe\u8ba1\u70ed\u8d1f\u8377120%<\/td><\/tr><tr><td>C5<\/td><td>\u51b7\u51dd\u7089\u672a\u914d\u7f6e\u5ba4\u5916\u6e29\u5ea6\u8865\u507f\u6216\u6c14\u5019\u8865\u507f\u529f\u80fd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl105\" class=\"wp-block-heading\">\u4e94\u3001\u6267\u884c\u6b65\u9aa4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u5728\u677f\u5757\u4e8c\u8f93\u51fa\u53ef\u9009\u65b9\u6848\u524d\uff0c\u5fc5\u987b\u9010\u9879\u6267\u884c\u4ee5\u4e0b\u68c0\u67e5\u3002\u9700\u8981\u67e5\u8be2\u6280\u672f\u539f\u7406\/\u6848\u4f8b\/\u56fd\u6807\u65f6\uff0c\u6309\u9644\u5f55\u96f6\u7684\u68c0\u7d22\u8def\u5f84\u6267\u884c\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u8d85\u914d\u7387\u6838\u7b97<\/strong>\uff1a\u4e3b\u673a\u989d\u5b9a\u5236\u51b7\u91cf kW vs \u5185\u673a\u603b\u51b7\u91cf kW<\/li>\n\n\n\n<li><strong>\u5185\u673a\u7cfb\u5217\u5339\u914d<\/strong>\uff1a\u5916\u673a\u7cfb\u5217 \u2192 \u5bf9\u5e94\u5185\u673a\u7cfb\u5217<\/li>\n\n\n\n<li><strong>\u70ed\u6e90\u529f\u7387\u5339\u914d<\/strong>\uff1a\u6700\u5c0f\u8f93\u51fa\u529f\u7387 vs \u623f\u95f4\u6052\u6e29\u8d1f\u8377<\/li>\n\n\n\n<li><strong>\u7ba1\u5f84\u5339\u914d\u68c0\u67e5<\/strong>\uff1a\u4e3b\u7ba1\u7ba1\u5f84 vs \u672b\u7aef\u6570\u91cf\/\u9762\u79ef<\/li>\n\n\n\n<li><strong>\u62a5\u8b66\u6761\u4ef6\u626b\u63cf<\/strong>\uff1a\u5bf9\u71674.3\u9010\u6761\u5224\u65ad\uff0c\u89e6\u53d1\u5219\u63d0\u793a<\/li>\n\n\n\n<li><strong>\u6807\u51c6\u5316\u6280\u672f\u8def\u5f84\u9009\u62e9<\/strong>\uff1a\u5982\u6d89\u53ca\u51fa\u98ce\u8212\u9002\u6027\u7b49\u95ee\u9898\uff0c\u67e5\u9605\u9644\u5f55\u4e09\uff0c\u5217\u51fa\u5168\u90e8\u53ef\u9009\u6280\u672f\u8def\u5f84\u800c\u975e\u53ea\u7ed9\u4e00\u79cd<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl106\" class=\"wp-block-heading\">\u516d\u3001\u9a8c\u8bc1\u6e05\u5355<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u8bbe\u8ba1\u5b8c\u6210\u540e\uff0cDS\u9010\u9879\u81ea\u68c0\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;\u8d85\u914d\u7387\u662f\u5426\u5728\u5141\u8bb8\u8303\u56f4\u5185<\/li>\n\n\n\n<li>&nbsp;\u5185\u673a\u578b\u53f7\u662f\u5426\u4e0e\u5916\u673a\u7cfb\u5217\u5339\u914d<\/li>\n\n\n\n<li>&nbsp;\u70ed\u6e90\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u662f\u5426 \u2264 \u623f\u95f4\u6052\u6e29\u8d1f\u8377<\/li>\n\n\n\n<li>&nbsp;\u4e3b\u7ba1\u7ba1\u5f84\u662f\u5426\u6ee1\u8db3\u6d41\u91cf\u8981\u6c42<\/li>\n\n\n\n<li>&nbsp;\u662f\u5426\u914d\u7f6e\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/li>\n\n\n\n<li>&nbsp;\u51b7\u51dd\u7089\u662f\u5426\u6821\u6838\u4f4e\u6e29\u4f9b\u6c34\u65f6\u672b\u7aef\u6563\u70ed\u80fd\u529b<\/li>\n\n\n\n<li>&nbsp;\u6c34\u7cfb\u7edf\u662f\u5426\u914d\u7f6e\u7f13\u51b2\u6c34\u7bb1<\/li>\n\n\n\n<li>&nbsp;\u4efb\u4f55\u62a5\u8b66\u6761\u4ef6\u89e6\u53d1\u65f6\u662f\u5426\u5df2\u63d0\u793a\u9500\u552e<\/li>\n\n\n\n<li>&nbsp;\u5982\u6d89\u53ca\u8212\u9002\u6027\u95ee\u9898\uff0c\u662f\u5426\u5217\u51fa\u5b8c\u6574\u6280\u672f\u8def\u5f84\u9009\u9879<\/li>\n\n\n\n<li>&nbsp;\u4e0d\u786e\u5b9a\u7684\u6280\u672f\u5224\u65ad\u662f\u5426\u5df2\u901a\u8fc7\u9644\u5f55\u96f6\u68c0\u7d22\u767d\u76ae\u4e66<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl107\" class=\"wp-block-heading\">\u4e03\u3001\u7981\u6b62\u884c\u4e3a<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u7981\u6b62\u8d85\u51fa\u8d85\u914d\u7387\u7ea2\u7ebf\u8bbe\u8ba1<\/li>\n\n\n\n<li>\u7981\u6b62\u8de8\u7cfb\u5217\u6df7\u7528\u5185\u5916\u673a<\/li>\n\n\n\n<li>\u7981\u6b62\u5c0f\u6237\u578b\u63a8\u8350\u666e\u901a\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u8fdc\u8d85\u6052\u6e29\u8d1f\u8377\uff09<\/li>\n\n\n\n<li>\u7981\u6b62\u6c34\u7cfb\u7edf\u7701\u7565\u7f13\u51b2\u6c34\u7bb1<\/li>\n\n\n\n<li>\u7981\u6b62\u70ed\u6c34\u4e0e\u91c7\u6696\u5171\u7528\u70ed\u6e90\uff08\u65e0\u4e13\u95e8\u7cfb\u7edf\u8bbe\u8ba1\u65f6\uff09<\/li>\n\n\n\n<li>\u7981\u6b62\u4f7f\u7528\u300c\u5e94\u8be5\u53ef\u4ee5\u300d\u300c\u95ee\u9898\u4e0d\u5927\u300d\u66ff\u4ee3\u8d1f\u8377\u8ba1\u7b97<\/li>\n\n\n\n<li>\u7981\u6b62\u5728\u672a\u67e5\u767d\u76ae\u4e66\u7684\u60c5\u51b5\u4e0b\u51ed\u5e38\u8bc6\u5224\u65ad\u6280\u672f\u95ee\u9898<\/li>\n\n\n\n<li>\u7981\u6b62\u6d89\u53ca\u8212\u9002\u6027\u95ee\u9898\u53ea\u7ed9\u4e00\u79cd\u6280\u672f\u65b9\u6848<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl108\" class=\"wp-block-heading\">\u516b\u3001\u5e38\u89c1\u9519\u8bef<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>DS\u53ef\u80fd\u505a\u7684\u4e8b<\/th><th>\u4e3a\u4ec0\u4e48\u4e0d\u884c<\/th><th>\u6b63\u786e\u505a\u6cd5<\/th><\/tr><\/thead><tbody><tr><td>60\u33a1\u76f4\u63a5\u63a8\u8350\u666e\u901a\u708924kW<\/td><td>\u6700\u5c0f\u8f93\u51fa8-10kW\u8fdc\u8d85\u6052\u6e29\u8d1f\u83772-3kW\uff0c\u5fc5\u7136\u9891\u7e41\u542f\u505c<\/td><td>\u63a8\u8350\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa3-4kW\uff09\u6216\u5206\u6bb5\u71c3\u70e7\u7089<\/td><\/tr><tr><td>\u300c\u8d8a\u5439\u8d8a\u51b7\u300d\u53ea\u63d0\u4e09\u7ba1\u5236\u5185\u673a<\/td><td>\u8212\u4eab\u53d8\u51b7\u5a92\u6d41\u91cf\u3001\u5c0a\u777f\u9ad8\u663e\u70ed\u3001\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u5747\u53ef\u89e3\u51b3<\/td><td>\u67e5\u9605\u9644\u5f55\u4e09\uff0c\u56db\u79cd\u8def\u5f84\u5168\u90e8\u5217\u51fa<\/td><\/tr><tr><td>\u6c34\u7cfb\u7edf\u7701\u7565\u7f13\u51b2\u6c34\u7bb1<\/td><td>\u538b\u7f29\u673a\u9891\u7e41\u542f\u505c\uff0c\u5bff\u547d\u5927\u5e45\u7f29\u77ed<\/td><td>\u5fc5\u987b\u914d\u7f6e\uff0c\u4e0d\u53ef\u7701\u7565<\/td><\/tr><tr><td>\u8d85\u914d\u7387\u300c\u591a\u653e\u4e00\u53f0\u4fdd\u9669\u300d<\/td><td>\u4e0d\u662f\u4fdd\u9669\uff0c\u662f\u6d6a\u8d39<\/td><td>\u5ba2\u6237\u4e8c\u5957\u623f\u53c2\u8003\u73b0\u4f4f\u623f\u5b9e\u9645\u4f7f\u7528\u6570\u636e<\/td><\/tr><tr><td>\u4e3b\u7ba1\u7ba1\u5f84\u7528De25\u914d\u5927\u9762\u79ef<\/td><td>\u8fdc\u7aef\u4e0d\u70ed\uff0c\u9a8c\u6536\u901a\u4e0d\u8fc7<\/td><td>\u6309\u9762\u79ef\u5339\u914d\u7ba1\u5f84<\/td><\/tr><tr><td>\u91c7\u6696\u70ed\u6c34\u5171\u7528\u70ed\u6e90\u4e0d\u52a0\u7cfb\u7edf\u8bbe\u8ba1<\/td><td>\u51ac\u5929\u6d17\u6fa1\u6c34\u6e29\u5ffd\u51b7\u5ffd\u70ed<\/td><td>\u5fc5\u987b\u5206\u79bb\u8bbe\u8ba1\u6216\u91c7\u7528\u7cfb\u7edf\u7089+\u6c34\u7bb1\u65b9\u6848<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl109\" class=\"wp-block-heading\">\u4e5d\u3001\u5173\u8054\u77e5\u8bc6\u5e93<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9700\u8981\u4ec0\u4e48<\/th><th>\u53bb\u54ea\u67e5<\/th><th>\u68c0\u7d22\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td>\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u6280\u672f\u539f\u7406<\/td><td>\u767d\u76ae\u4e66\u300a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66\u300b<\/td><td>IMA\u68c0\u7d22\u300c\u591a\u8054\u673a \u538b\u7f29\u673a \u8d85\u914d\u7387\u300d<\/td><\/tr><tr><td>\u5730\u6696\u7cfb\u7edf\u6280\u672f\u539f\u7406<\/td><td>\u767d\u76ae\u4e66\u300a\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\u300b<\/td><td>IMA\u68c0\u7d22\u300c\u70ed\u8d1f\u8377 \u7ba1\u5f84 \u963b\u6c27\u300d<\/td><\/tr><tr><td>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u539f\u7406<\/td><td>\u767d\u76ae\u4e66\u300a\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u767d\u76ae\u4e66\u300b<\/td><td>IMA\u68c0\u7d22\u300c\u4e00\u6b21\u7cfb\u7edf \u7f13\u51b2\u6c34\u7bb1 \u98ce\u76d8\u9009\u578b\u300d<\/td><\/tr><tr><td>\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u539f\u7406<\/td><td>\u767d\u76ae\u4e66\u300a\u4e94\u6052\u7cfb\u7edf\u767d\u76ae\u4e66\u300b<\/td><td>IMA\u68c0\u7d22\u300c\u6e29\u6e7f\u53cc\u63a7 \u9664\u6e7f\u65b0\u98ce\u300d<\/td><\/tr><tr><td>\u516d\u7ef4\u5ea6\/20\u5e74\u603b\u8d26\/\u5168\u751f\u547d\u5468\u671f<\/td><td>\u767d\u76ae\u4e66\u300a\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66\u300b<\/td><td>IMA\u68c0\u7d22\u300c\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u300d<\/td><\/tr><tr><td>\u5ba2\u6237\u75db\u70b9\u4e0e\u89e3\u51b3\u65b9\u6848\u6620\u5c04<\/td><td>\u767d\u76ae\u4e66\u300a\u5b9e\u6218\u624b\u518c\u300b\u7b2c\u4e09\u7bc7<\/td><td>IMA\u68c0\u7d22\u300c\u7528\u6237\u9700\u6c42 \u75db\u70b9\u5206\u6790\u300d<\/td><\/tr><tr><td>\u552e\u540e\u5e38\u89c1\u95ee\u9898<\/td><td>\u767d\u76ae\u4e66\u300a\u5b9e\u6218\u624b\u518c\u300b\u7b2c\u4e03\u7bc7<\/td><td>IMA\u68c0\u7d22\u300c\u5e38\u89c1\u95ee\u9898 \u9884\u9632\u63aa\u65bd\u300d<\/td><\/tr><tr><td>\u56fd\u6807\u539f\u6587\u9a8c\u8bc1<\/td><td>\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf<\/td><td>\u8f93\u5165\u6807\u51c6\u7f16\u53f7\u76f4\u63a5\u67e5\u8be2<\/td><\/tr><tr><td>\u5168\u54c1\u7c7b\u4ea7\u54c1\u9762\u4ef7<\/td><td>\u6307\u4ee42<\/td><td>\u5168\u54c1\u7c7b\u4ef7\u683c\u8868<\/td><\/tr><tr><td>\u65b9\u6848\u751f\u6210\u6d41\u7a0b<\/td><td>\u6307\u4ee40<\/td><td>\u4e94\u5927\u677f\u5757\u6267\u884c\u89c4\u5219<\/td><\/tr><tr><td>\u9500\u552e\u7b56\u7565\u4e0e\u4eba\u9645\u8fde\u63a5<\/td><td>\u6307\u4ee45<\/td><td>\u516d\u5927\u57fa\u77f3 + \u7b56\u7565\u5361\u5e93<\/td><\/tr><tr><td>\u4f1a\u5458\u5236\u6743\u76ca\u4e0e\u89c4\u5219<\/td><td>\u4f1a\u5458\u5236\u4e13\u9879\u7b14\u8bb0<\/td><td>\u6743\u76ca\u4e0e\u65f6\u95f4\u7ebf<\/td><\/tr><tr><td>\u5ba2\u6237\u6848\u4f8b\uff08\u540c\u6237\u578b\u53c2\u7167\uff09<\/td><td>D:\\\u9f99\u8109\u6696\u901a\u5ba2\u6237\u6848\u4f8b\u5e93\\<\/td><td>IMA\u68c0\u7d22\u300c\u6237\u578b+\u7cfb\u7edf\u7c7b\u578b\u300d<\/td><\/tr><tr><td>\u5baa\u6cd5\u8bbe\u8ba1\u7406\u5ff5<\/td><td>\u5ba2\u6237\u6210\u529fGEO\u5baa\u6cd5 V6.0<\/td><td>\u7b2c\u4e09\u7ae0\uff1a\u80fd\u91cf\u7ba1\u7406<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl1f0\" class=\"wp-block-heading\">\u9644\u5f55\u96f6\uff1a\u77e5\u8bc6\u68c0\u7d22\u8def\u5f84\u603b\u8868<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u9700\u8981\u67e5\u8be2\u4ee5\u4e0b\u5185\u5bb9\u65f6\uff0c\u6309\u672c\u8868\u8def\u5f84\u68c0\u7d22\u3002\u6b63\u6587\u4e0d\u52a0\u8f7d\u672c\u8868\u5185\u5bb9\uff0c\u6309\u9700\u8c03\u7528\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9700\u8981\u67e5\u4ec0\u4e48<\/th><th>\u53bb\u54ea\u4e2a\u77e5\u8bc6\u5e93<\/th><th>\u68c0\u7d22\u5173\u952e\u8bcd\u793a\u4f8b<\/th><th>\u63d0\u793a\u8bcd\u6a21\u677f<\/th><\/tr><\/thead><tbody><tr><td>\u6c1f\u7cfb\u7edf\u539f\u7406<\/td><td>01_\u6c1f\u7cfb\u7edf\u624b\u518c<\/td><td>\u591a\u8054\u673a\u3001\u538b\u7f29\u673a\u3001\u8d85\u914d\u7387\u3001\u51b7\u5a92\u6d41\u91cf<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u5173\u952e\u8bcd\u300d\uff0c\u63d0\u53d6\u300a\u6c1f\u7cfb\u7edf\u624b\u518c\u300b\u76f8\u5173\u7ae0\u8282<\/code><\/td><\/tr><tr><td>\u5730\u6696\u8bbe\u8ba1<\/td><td>02_\u91c7\u6696\u624b\u518c<\/td><td>\u70ed\u8d1f\u8377\u3001\u7ba1\u5f84\u9009\u578b\u3001\u963b\u6c27\u7ba1\u3001\u7ae0\u9c7c\u5f0f<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u5173\u952e\u8bcd\u300d\uff0c\u63d0\u53d6\u300a\u91c7\u6696\u624b\u518c\u300b\u76f8\u5173\u7ae0\u8282<\/code><\/td><\/tr><tr><td>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/td><td>03_\u6c34\u7cfb\u7edf\u624b\u518c<\/td><td>\u4e00\u6b21\u7cfb\u7edf\u3001\u7f13\u51b2\u6c34\u7bb1\u3001PPR\u7ba1\u58c1\u539a\u3001\u98ce\u76d8\u5339\u914d<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u5173\u952e\u8bcd\u300d\uff0c\u63d0\u53d6\u300a\u6c34\u7cfb\u7edf\u624b\u518c\u300b\u76f8\u5173\u7ae0\u8282<\/code><\/td><\/tr><tr><td>\u4e94\u6052\u7cfb\u7edf<\/td><td>04_\u4e94\u6052\u624b\u518c<\/td><td>\u6e29\u6e7f\u53cc\u63a7\u3001\u9664\u6e7f\u65b0\u98ce\u3001\u8f90\u5c04\u51b7\u6696<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u5173\u952e\u8bcd\u300d\uff0c\u63d0\u53d6\u300a\u4e94\u6052\u624b\u518c\u300b\u76f8\u5173\u7ae0\u8282<\/code><\/td><\/tr><tr><td>\u5c45\u5bb6\u73af\u5883\u6574\u4f53\u8bbe\u8ba1<\/td><td>05_\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66<\/td><td>\u516d\u7ef4\u5ea6\u5bf9\u6bd4\u300120\u5e74\u603b\u8d26\u3001\u5168\u751f\u547d\u5468\u671f\u6210\u672c<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u5173\u952e\u8bcd\u300d\uff0c\u63d0\u53d6\u300a\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66\u300b\u76f8\u5173\u7ae0\u8282<\/code><\/td><\/tr><tr><td>\u5ba2\u6237\u75db\u70b9\u4e0e\u65b9\u6848\u6620\u5c04<\/td><td>\u5b9e\u6218\u624b\u518c\u7b2c\u4e09\u7bc7<\/td><td>\u7528\u6237\u9700\u6c42\u3001\u75db\u70b9\u5206\u6790\u3001\u89e3\u51b3\u65b9\u6848<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u5173\u952e\u8bcd+\u573a\u666f\u300d\uff0c\u63d0\u53d6\u5339\u914d\u7684\u75db\u70b9\u6620\u5c04\u65b9\u6848<\/code><\/td><\/tr><tr><td>\u552e\u540e\u5e38\u89c1\u95ee\u9898<\/td><td>\u5b9e\u6218\u624b\u518c\u7b2c\u4e03\u7bc7<\/td><td>\u5e38\u89c1\u95ee\u9898\u3001\u53d1\u751f\u6982\u7387\u3001\u9884\u9632\u63aa\u65bd<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u95ee\u9898\u7c7b\u578b\u300d\uff0c\u63d0\u53d6\u552e\u540e\u95ee\u9898\u5e93\u76f8\u5173\u5185\u5bb9<\/code><\/td><\/tr><tr><td>\u540c\u6237\u578b\u5ba2\u6237\u6848\u4f8b<\/td><td>\u5ba2\u6237\u6848\u4f8b\u5e93<\/td><td>\u6237\u578b\u9762\u79ef+\u7cfb\u7edf\u7c7b\u578b\uff08\u5982\u300c93\u33a1 \u51b7\u51dd\u7089\u5730\u6696\u300d\uff09<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u6237\u578b+\u7cfb\u7edf\u7c7b\u578b\u300d\uff0c\u63d0\u53d6\u540c\u7c7b\u578b\u5ba2\u6237\u6848\u4f8b<\/code><\/td><\/tr><tr><td>\u56fd\u6807\u9a8c\u8bc1<\/td><td>\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf<\/td><td>GB 50736-2012\u3001JGJ 142-2012<\/td><td><code>\u5c06\u6807\u51c6\u7f16\u53f7\u8f93\u5165\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf\uff0c\u9a8c\u8bc1\u5f15\u7528\u662f\u5426\u51c6\u786e<\/code><\/td><\/tr><tr><td>\u70ed\u8d1f\u8377\u8ba1\u7b97<\/td><td>\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66\u7b2c\u56db\u7ae0<\/td><td>\u70ed\u8d1f\u8377\u516c\u5f0f\u3001GB50736\u3001\u6210\u90fd\u91c7\u6696\u8d1f\u8377<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u70ed\u8d1f\u8377\u8ba1\u7b97\u300d\uff0c\u63d0\u53d6\u767d\u76ae\u4e66\u7b2c\u56db\u7ae0\u5b8c\u6574\u63a8\u5bfc<\/code><\/td><\/tr><tr><td>\u65e5\u7acb\u4ea7\u54c1\u53c2\u6570<\/td><td>\u4ea7\u54c1\u53c2\u6570\u5e93<\/td><td>\u8212\u4eab125\u3001\u5c0a\u777f\u5168\u6548\u3001\u6c34\u5885\u9002FX<\/td><td><code>\u5728IMA\u4e2d\u641c\u7d22\u300c\u4ea7\u54c1\u578b\u53f7\u300d\uff0c\u63d0\u53d6\u5bf9\u5e94\u53c2\u6570\u548c\u4ef7\u683c<\/code><\/td><\/tr><tr><td>\u9700\u6c42\u5c42\u6b21\u7406\u8bba<\/td><td>\u5baa\u6cd5V6.0\u7b2c\u4e09\u7ae0<\/td><td>\u80fd\u91cf\u7ba1\u7406\u3001\u9700\u6c42\u4e03\u5c42\u6b21<\/td><td><code>\u67e5\u9605\u5baa\u6cd5V6.0\u7b2c\u4e09\u7ae0\u300c\u80fd\u91cf\u7ba1\u7406\u300d\u5b8c\u6574\u9610\u8ff0<\/code><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"\u9644\u5f55\u4e00\u5927\u767d\u8bdd\u7c7b\u6bd4\u5e93\" class=\"wp-block-heading zl1f1\">\u9644\u5f55\u4e00\uff1a\u5927\u767d\u8bdd\u7c7b\u6bd4\u5e93<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u4e66\u548c\u5ba2\u6237\u6c9f\u901a\u4e2d\u9047\u5230\u6280\u672f\u672f\u8bed\uff0c\u4ece\u6b64\u5e93\u8c03\u7528\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4e13\u4e1a\u672f\u8bed<\/th><th>\u5ba2\u6237\u80fd\u542c\u61c2\u7684\u7c7b\u6bd4<\/th><\/tr><\/thead><tbody><tr><td>\u8d85\u914d\u7387\u8fc7\u9ad8<\/td><td>\u300c\u5927\u9a6c\u62c9\u5c0f\u8f66\uff0c\u6cb9\u94b1\u82b1\u4e86\uff0c\u52b2\u4f7f\u4e0d\u4e0a\u300d<\/td><\/tr><tr><td>\u6c34\u529b\u5931\u8861<\/td><td>\u300c\u50cf\u6c34\u538b\u4e0d\u591f\u65f6\uff0c\u697c\u4e0a\u6d17\u6fa1\u697c\u4e0b\u6ca1\u6c34\u300d<\/td><\/tr><tr><td>\u7ae0\u9c7c\u5f0f\u5e03\u7ba1<\/td><td>\u300c\u50cf\u914d\u7535\u7bb1\uff0c\u6bcf\u8def\u7a7a\u6c14\u5f00\u5173\u72ec\u7acb\u63a7\u5236\u300d<\/td><\/tr><tr><td>\u9891\u7e41\u542f\u505c<\/td><td>\u300c\u50cf\u5835\u8f66\u65f6\u4e00\u811a\u6cb9\u95e8\u4e00\u811a\u5239\u8f66\uff0c\u6700\u8d39\u6cb9\u300d<\/td><\/tr><tr><td>\u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c<\/td><td>\u300c\u50cf\u6c7d\u8f66\u5300\u901f\u8dd1\u9ad8\u901f\u6700\u7701\u6cb9\u300d<\/td><\/tr><tr><td>\u4e3b\u7ba1\u7ba1\u5f84\u4e0d\u8db3<\/td><td>\u300c\u7528\u7ec6\u5438\u7ba1\u559d\u73cd\u73e0\u5976\u8336\uff0c\u7d2f\u6b7b\u4e5f\u5438\u4e0d\u4e0a\u6765\u300d<\/td><\/tr><tr><td>\u65e0\u7ebf\u8054\u52a8\u63a7\u5236<\/td><td>\u300c\u50cf\u7a7a\u8c03\u8bbe\u4e86\u5b9a\u65f6\uff0c\u5230\u4e86\u6e29\u5ea6\u81ea\u5df1\u5173\u300d<\/td><\/tr><tr><td>\u963b\u6c27\u7ba1<\/td><td>\u300c\u50cf\u771f\u7a7a\u5305\u88c5\u7684\u98df\u54c1\uff0c\u9694\u7edd\u7a7a\u6c14\u4e0d\u53d8\u8d28\u300d<\/td><\/tr><tr><td>\u8bbe\u8ba1\u8d1f\u8377 vs \u80fd\u8017\u8d1f\u8377<\/td><td>\u300c\u4e70\u8f66\u770b\u6700\u5927\u9a6c\u529b\uff0c\u7b97\u6cb9\u8d39\u770b\u5e02\u533a\u6cb9\u8017\u300d<\/td><\/tr><tr><td>\u6696\u6c14\u7247\u7cfb\u7edf\u7ba1\u9053<\/td><td>\u300c\u6696\u6c14\u7247\u7528\u94dd\u5851\u7ba1\u662f\u884c\u89c4\uff0c\u5c31\u50cf\u6c34\u7ba1\u7528PPR\u4e00\u6837\u666e\u904d\u300d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl1f2\" class=\"wp-block-heading\">\u9644\u5f55\u4e8c\uff1a\u914d\u7f6e\u8bca\u65ad\u4e0e\u8d85\u914d\u81ea\u67e5\u6e05\u5355<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u677f\u5757\u4e09\u8f93\u51fa\u914d\u7f6e\u6e05\u5355\u524d\uff0cDS\u9010\u9879\u6267\u884c\u5e76\u6253\u52fe\u3002<\/p>\n\n\n\n<h3 id=\"\u914d\u7f6e\u5408\u7406\u6027\u5206\u6790\u8bca\u65ad\" class=\"wp-block-heading\">\u914d\u7f6e\u5408\u7406\u6027\u5206\u6790\u8bca\u65ad<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u68c0\u67e5\u9879<\/th><th>\u914d\u7f6e\u503c<\/th><th class=\"has-text-align-center\" data-align=\"center\">\u662f\u5426\u5408\u7406<\/th><th>\u5206\u6790\u8bca\u65ad<\/th><\/tr><\/thead><tbody><tr><td>\u8d85\u914d\u7387<\/td><td>XX%<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td>\u662f\u5426\u5728\u5408\u7406\u533a\u95f4\uff1f<\/td><\/tr><tr><td>\u4e3b\u7ba1\u7ba1\u5f84<\/td><td>DeXX<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td>\u6d41\u91cf\u662f\u5426\u5145\u8db3\uff1f<\/td><\/tr><tr><td>\u56de\u8def\u6570<\/td><td>XX\u8def<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td>\u5355\u56de\u8def\u9762\u79ef\u662f\u5426\u8d85\u6807\uff1f<\/td><\/tr><tr><td>\u5ba4\u6e29\u8054\u52a8<\/td><td>\u6709\/\u65e0<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td>\u662f\u5426\u80fd\u675c\u7edd\u65e0\u6548\u4ea7\u70ed\uff1f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"\u51b7\u70ed\u8d1f\u8377\u8d85\u914d\u81ea\u67e5\u5f3a\u5236\u6267\u884c\" class=\"wp-block-heading\">\u51b7\u70ed\u8d1f\u8377\u8d85\u914d\u81ea\u67e5\uff08\u5f3a\u5236\u6267\u884c\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u68c0\u67e5\u9879<\/th><th>\u6838\u67e5\u65b9\u6cd5<\/th><th class=\"has-text-align-center\" data-align=\"center\">\u662f\u5426\u901a\u8fc7<\/th><\/tr><\/thead><tbody><tr><td>\u4e3b\u673a\u529f\u7387\u4e0e\u672b\u7aef\u603b\u80fd\u529b\u662f\u5426\u5339\u914d\uff1f<\/td><td>\u4e3b\u673a\u989d\u5b9a\u5236\u51b7\u91cf kW vs \u5185\u673a\u603b\u51b7\u91cf kW\uff0c\u8d85\u914d\u7387\u662f\u5426\u5728\u5408\u7406\u533a\u95f4\uff1f<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>\u662f\u5426\u5b58\u5728\u300c\u4e60\u60ef\u6027\u8d85\u914d\u300d\uff1f<\/td><td>\u662f\u5426\u6309200W\/\u33a1\u4ee5\u4e0a\u914d\u7f6e\u800c\u5ba2\u6237\u5b9e\u9645\u53ea\u9700120W\/\u33a1\uff1f<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>\u5185\u673a\u53f0\u6570\u662f\u5426\u5b58\u5728\u5197\u4f59\uff1f<\/td><td>\u662f\u5426\u6709\u300c\u591a\u653e\u4e00\u53f0\u4fdd\u9669\u300d\u7684\u8bbe\u8ba1\u60ef\u6027\uff1f\u5ba2\u6237\u5b9e\u9645\u9700\u6c42\u662f\u51e0\u53f0\uff1f<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u7cfb\u7edf\u662f\u5426\u6821\u6838\u4f4e\u6e29\u4f9b\u6c34\u65f6\u672b\u7aef\u6563\u70ed\u80fd\u529b\uff1f<\/td><td>\u4f4e\u6e29\u4f9b\u6c34\u65f6\u672b\u7aef\u6563\u70ed\u91cf\u662f\u5426\u2265\u623f\u95f4\u70ed\u8d1f\u8377\uff1f<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u67e5\u94c1\u5f8b<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u914d\u7f6e\u4e0d\u662f\u4e3a\u4e86\u300c\u4fdd\u9669\u300d\uff0c\u662f\u4e3a\u4e86\u300c\u5339\u914d\u300d<\/li>\n\n\n\n<li>\u591a\u53f0 \u2260 \u597d\u6548\u679c\uff0c\u540c\u5f00\u7387\u4f4e\u65f6\u5927\u4e3b\u673a\u53cd\u800c\u8017\u80fd<\/li>\n\n\n\n<li>\u5ba2\u6237\u4e8c\u5957\u623f \/ \u6539\u9020\u9879\u76ee\uff0c\u5fc5\u987b\u53c2\u8003\u5176\u73b0\u4f4f\u623f\u5b9e\u9645\u4f7f\u7528\u4e60\u60ef\u548c\u8d39\u7528\u6570\u636e<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl1f3\" class=\"wp-block-heading\">\u9644\u5f55\u4e09\uff1a\u6807\u51c6\u5316\u6280\u672f\u8def\u5f84\u8868<\/h2>\n\n\n\n<h3 id=\"\u51fa\u98ce\u8212\u9002\u6027\u6280\u672f\u8def\u5f84\" class=\"wp-block-heading\">\u51fa\u98ce\u8212\u9002\u6027\u6280\u672f\u8def\u5f84<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u5ba2\u6237\u53cd\u9988\u300c\u8d8a\u5439\u8d8a\u51b7\u300d\u300c\u7a7a\u8c03\u98ce\u5439\u5f97\u4e0d\u8212\u670d\u300d\u65f6\uff0cDS\u5fc5\u987b\u5728\u65b9\u6848\u4e2d\u5217\u51fa\u4ee5\u4e0b\u5168\u90e8\u6280\u672f\u8def\u5f84\uff0c\u8ba9\u5ba2\u6237\u81ea\u4e3b\u9009\u62e9\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6280\u672f\u8def\u5f84<\/th><th>\u5b9e\u73b0\u65b9\u5f0f<\/th><th>\u9002\u7528\u673a\u578b<\/th><th>\u51fa\u98ce\u7279\u6027<\/th><th>\u6848\u4f8b\u9a8c\u8bc1<\/th><\/tr><\/thead><tbody><tr><td>\u53d8\u51b7\u5a92\u6d41\u91cf<\/td><td>\u63a7\u5236\u51b7\u5a92\u6d41\u91cf\uff0c\u63d0\u5347\u84b8\u53d1\u6e29\u5ea6\uff0c\u51fa\u98ce\u53e3\u6e29\u5ea6\u63d0\u9ad8<\/td><td>\u8212\u4eab\u7cfb\u5217<\/td><td>\u51fa\u98ce\u53e312-15\u2103\uff0c\u57fa\u672c\u8212\u9002<\/td><td>\u2014<\/td><\/tr><tr><td>\u9ad8\u663e\u70ed\u6a21\u5f0f<\/td><td>\u964d\u4f4e\u9664\u6e7f\u6bd4\u4f8b\uff0c\u63d0\u5347\u663e\u70ed\u5236\u51b7\u91cf<\/td><td>\u5c0a\u777f\u7cfb\u5217<\/td><td>\u51c9\u800c\u4e0d\u51b7\uff0c\u6e7f\u5ea6\u53ef\u63a7<\/td><td>\u2014<\/td><\/tr><tr><td>\u4e09\u7ba1\u5236\u53cc\u6362\u70ed<\/td><td>\u9664\u6e7f\u540e\u56de\u6536\u4f59\u70ed\u518d\u52a0\u70ed\uff0c\u4e0d\u964d\u6e29\u9664\u6e7f<\/td><td>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5185\u673a<\/td><td>\u51fa\u98ce\u63a5\u8fd1\u5ba4\u6e29<\/td><td>\u5929\u5e9c\u516c\u9986\u51fa\u98ce\u53e3\u5b9e\u6d4b<\/td><\/tr><tr><td>\u6c34\u7cfb\u7edf<\/td><td>\u6c34\u4f5c\u51b7\u5a92\uff0c\u4e8c\u6b21\u6362\u70ed\uff0c\u6e29\u5dee\u5c0f<\/td><td>\u6c34\u5885\u9002\u7cfb\u5217<\/td><td>\u51fa\u98ce15-20\u2103\uff0c\u6700\u67d4\u548c<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"\u4e24\u8054\u4f9b\u6280\u672f\u8def\u5f84\" class=\"wp-block-heading\">\u4e24\u8054\u4f9b\u6280\u672f\u8def\u5f84<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7c7b\u578b<\/th><th>\u7a7a\u8c03\u4fa7<\/th><th>\u5236\u51b7\u7279\u70b9<\/th><th>\u5236\u70ed\u7279\u70b9<\/th><th>\u9002\u5408\u8c01<\/th><\/tr><\/thead><tbody><tr><td>\u5929\u6c1f\u5730\u6c34<\/td><td>\u6c1f\u7cfb\u7edf<\/td><td>\u5236\u51b7\u5feb<\/td><td>\u5730\u6696<\/td><td>\u5bf9\u5236\u51b7\u901f\u5ea6\u6709\u8981\u6c42\u7684\u5ba2\u6237<\/td><\/tr><tr><td>\u5929\u6c34\u5730\u6c34<\/td><td>\u6c34\u7cfb\u7edf<\/td><td>\u5236\u51b7\u6162\u4f46\u67d4\u548c<\/td><td>\u5730\u6696<\/td><td>\u5bf9\u8212\u9002\u5ea6\u8981\u6c42\u9ad8\u3001\u4e0d\u4ecb\u610f\u5236\u51b7\u6162\u7684\u5ba2\u6237<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7248\u672c\uff1aV5.0\u66f4\u65b0\u65e5\u671f\uff1a2026\u5e745\u67082 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-660","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u7248\u672c\uff1aV5.0\u66f4\u65b0\u65e5\u671f\uff1a2026\u5e745\u67082 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=660\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-22T04:22:29+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=660\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=660\",\"name\":\"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-13T08:39:46+00:00\",\"dateModified\":\"2026-05-22T04:22:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=660#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=660\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=660#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 - \u9f99\u8109\u6696\u901a","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"zh_CN","og_type":"article","og_title":"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 - \u9f99\u8109\u6696\u901a","og_description":"\u7248\u672c\uff1aV5.0\u66f4\u65b0\u65e5\u671f\uff1a2026\u5e745\u67082 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=660","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-22T04:22:29+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=660","url":"https:\/\/longmai-nt.com\/?page_id=660","name":"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-13T08:39:46+00:00","dateModified":"2026-05-22T04:22:29+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=660#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=660"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=660#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6307\u4ee41\uff1a\u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u5ba2\u6237\u77e5\u8bc6"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=660"}],"version-history":[{"count":7,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/660\/revisions"}],"predecessor-version":[{"id":1313,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/660\/revisions\/1313"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}