{"id":669,"date":"2026-05-13T17:12:24","date_gmt":"2026-05-13T09:12:24","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=669"},"modified":"2026-11-21T18:06:10","modified_gmt":"2026-11-21T10:06:10","slug":"02_%e5%a3%81%e6%8c%82%e7%82%89%e3%80%81%e5%9c%b0%e6%9a%96%e3%80%81%e6%9a%96%e6%b0%94%e7%89%87%e3%80%81%e7%83%ad%e6%b0%b4%e7%b3%bb%e7%bb%9f-%c2%b7-%e6%8a%80%e6%9c%af%e6%bc%94%e8%bf%9b%e4%b8%8e%e5%ae%9e","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=669","title":{"rendered":"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c"},"content":{"rendered":"<div class=\"lm-geo\" data-book=\"NT02\" data-cat=\"\u91c7\u6696\u70ed\u6c34\" data-layer=\"\u6839\" data-code=\"NT02\" data-step=\"1\" data-elem=\"\" data-q=\"\u5bb6\u91cc\u7684\u91c7\u6696\u548c\u70ed\u6c34\uff0c\u4ece\u54ea\u770b\u8d77\"><\/div>\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c<\/strong>\uff1aV2.1<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e7410\u670824\u65e5<\/p>\n<h2 class=\"wp-block-heading\">\u3010\u672c\u7cfb\u5217\u624b\u518c\u8bf4\u660e\u3011<\/h2>\n<p class=\"wp-block-paragraph\">\u672c\u624b\u518c\u4e3a<strong>\u9f99\u8109\u6696\u901a\u6280\u672f\u624b\u518c\u7cfb\u5217\u7b2c 02 \u53f7<\/strong>\uff0c\u5168\u5957\u5171 4 \u518c\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5e8f\u53f7<\/strong><\/td>\n<td><strong>\u540d\u79f0<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>01<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=667\">\u300a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u6c1f\u673a\u539f\u7406\u3001\u4ea7\u54c1\u5bf9\u4f4d\u3001\u538b\u7f29\u673a\u9009\u578b\u3001\u4e09\u7ba1\u5236<\/td>\n<\/tr>\n<tr>\n<td><strong>02<\/strong><\/td>\n<td><strong>\u300a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b\uff08\u672c\u9875\uff09<\/strong><\/td>\n<td>\u71c3\u6c14\u70ed\u6e90\u3001\u7ba1\u8def\u8bbe\u8ba1\u3001\u6c34\u529b\u5e73\u8861\u3001\u70ed\u6c34\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td><strong>03<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u300a\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u4e09\u8054\u4f9b\uff0c\u4e09\u6761\u5206\u652f\u600e\u4e48\u9009<\/td>\n<\/tr>\n<tr>\n<td><strong>04<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=673\">\u300a\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u6e29\u6e7f\u6c27\u6d01\u9759\u4e94\u7ef4\u3001\u5168\u5c4b\u5168\u611f 3.0\u3001\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">\u672c\u518c\u7ba1\u4ec0\u4e48\uff0c\u4e0d\u7ba1\u4ec0\u4e48<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u7ba1<\/strong>\uff1a\u71c3\u6c14\u58c1\u6302\u7089\uff08\u666e\u901a\u7089\uff0f\u51b7\u51dd\u7089\uff09\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u751f\u6d3b\u70ed\u6c34\uff0c\u4ee5\u53ca\u628a\u5b83\u4eec\u8fde\u8d77\u6765\u7684\u6c34\u529b\u5e73\u8861\u4e0e\u8054\u52a8\u63a7\u5236\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u7ba1<\/strong>\uff1a\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\uff08\u5929\u6c1f\u5730\u6c34\uff0f\u5929\u6c34\u5730\u6c34\uff09\u2014\u2014\u90a3\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=671\">03 \u53f7\u624b\u518c\u300a\u4e24\u8054\u4f9b\u300b<\/a>\u3002\u4e94\u6052\u7684\u65b0\u98ce\u9664\u6e7f\u4e0e\u9632\u7ed3\u9732\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=673\">04 \u53f7\u624b\u518c\u300a\u4e94\u6052\u207a\u7cfb\u7edf\u300b<\/a>\u3002\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u672c\u8eab\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=667\">01 \u53f7\u624b\u518c<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u8fd9\u6761\u754c\u7ebf\u8981\u5212\u6e05\uff0c\u662f\u56e0\u4e3a\u71c3\u6c14\u548c\u7a7a\u6c14\u80fd\u4e89\u7684\u662f\u540c\u4e00\u4e2a\u4f4d\u7f6e\u2014\u2014\u70ed\u6e90\u3002\u9009\u71c3\u6c14\u8fd8\u662f\u9009\u7a7a\u6c14\u80fd\uff0c\u662f 03 \u53f7\u624b\u518c\u7684\u4e8b\uff1b\u9009\u4e86\u71c3\u6c14\u4e4b\u540e\uff0c\u7089\u5b50\u600e\u4e48\u6311\u3001\u672b\u7aef\u600e\u4e48\u914d\u3001\u6c34\u600e\u4e48\u5e73\u8861\uff0c\u624d\u662f\u672c\u518c\u7684\u4e8b\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u9605\u8bfb\u8def\u5f84\u5efa\u8bae<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u91c7\u6696\u7cfb\u7edf\u5165\u95e8<\/strong>\uff1a\u672c\u624b\u518c\u4e3a\u6838\u5fc3\uff0c\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u90fd\u8bb2\u5230<\/li>\n<li><strong>\u70ed\u6e90\u600e\u4e48\u9009<\/strong>\uff1a\u71c3\u6c14\u8fd8\u662f\u7a7a\u6c14\u80fd\uff0c\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=671\">03 \u53f7\u624b\u518c\u300a\u4e24\u8054\u4f9b\u300b<\/a><\/li>\n<li><strong>\u5f80\u9ad8\u7aef\u8212\u9002\u8d70<\/strong>\uff1a\u672c\u624b\u518c \uff0b <a href=\"https:\/\/longmai-nt.com\/?page_id=673\">04 \u53f7\u624b\u518c\uff08\u4ece\u91c7\u6696\u5230\u4e94\u6052\uff09<\/a><\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u53c9\u5f15\u7528\u89c4\u5219<\/strong>\uff1a\u672c\u624b\u518c\u4e2d\u5f15\u7528\u5176\u4ed6\u624b\u518c\u5185\u5bb9\u65f6\uff0c\u4ee5\u5e8f\u53f7\u6807\u6ce8\uff08\u5982\"\u8be6\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=671\">03 \u53f7\u624b\u518c<\/a>\u7b2c 2.1 \u8282\"\uff09\uff0c\u88ab\u5f15\u7528\u7684\u624b\u518c\u540d\u79f0\u90fd\u53ef\u4ee5\u70b9\u5f00\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u672c\u518c\u8986\u76d6<\/strong>\uff1a\u6280\u672f\u539f\u7406\u3001\u7cfb\u7edf\u67b6\u6784\u4e0e\u8bbe\u8ba1\u89c4\u8303\u3001\u70ed\u6c34\u7cfb\u7edf\u4e13\u9879\u3001\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u3001\u6545\u969c\u56fe\u8c31\u4e0e\u5b9e\u64cd\u7ef4\u62a4\u3001\u80fd\u8017\u5bf9\u6bd4\u3001\u5b9e\u6218\u65b9\u6848\u4e0e\u5ba2\u6237\u6c9f\u901a\u3001\u552e\u540e\u7ef4\u4fdd\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u90e8\u5206<\/strong><\/td>\n<td><strong>\u6807\u9898<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e00\u90e8\u5206<\/strong><\/td>\n<td>\u6280\u672f\u6f14\u8fdb\u4e0e\u6838\u5fc3\u539f\u7406<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e8c\u90e8\u5206<\/strong><\/td>\n<td>\u7cfb\u7edf\u67b6\u6784\u4e0e\u8bbe\u8ba1\u89c4\u8303<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e09\u90e8\u5206<\/strong><\/td>\n<td>\u70ed\u6c34\u7cfb\u7edf\u4e13\u9879\u8bbe\u8ba1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u56db\u90e8\u5206<\/strong><\/td>\n<td>\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u6307\u5357<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e94\u90e8\u5206<\/strong><\/td>\n<td>\u6545\u969c\u56fe\u8c31\u4e0e\u5b9e\u64cd\u7ef4\u62a4<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u516d\u90e8\u5206<\/strong><\/td>\n<td>\u80fd\u8017\u5bf9\u6bd4\u4e0e\u7ecf\u6d4e\u5206\u6790<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e03\u90e8\u5206<\/strong><\/td>\n<td>\u5b9e\u6218\u65b9\u6848\u4e0e\u5ba2\u6237\u6c9f\u901a<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u516b\u90e8\u5206<\/strong><\/td>\n<td>\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9644\u5f55<\/strong><\/td>\n<td>\u5173\u952e\u6570\u636e\u3001\u516c\u5f0f\u4e0e\u89c4\u8303<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e00\u90e8\u5206\uff1a\u6280\u672f\u6f14\u8fdb\u4e0e\u6838\u5fc3\u539f\u7406<\/h2>\n<h3 class=\"wp-block-heading\">1.1 \u58c1\u6302\u7089\u7684\u6280\u672f\u6f14\u8fdb\uff1a\u4ece\u666e\u901a\u7089\u5230\u51b7\u51dd\u7089<\/h3>\n<p class=\"wp-block-paragraph\"><strong>1.1.1 \u666e\u901a\u7089\uff08\u5927\u6c14\u5f0f\u71c3\u70e7\uff09\u7684\u7269\u7406\u7ed3\u6784<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u666e\u901a\u58c1\u6302\u7089\u91c7\u7528<strong>\u5927\u6c14\u5f0f\u71c3\u70e7<\/strong>\uff08\u90e8\u5206\u9884\u6df7\u71c3\u70e7\uff09\u6280\u672f\uff0c\u5176\u7269\u7406\u7ed3\u6784\u5982\u4e0b\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u90e8\u4ef6<\/strong><\/td>\n<td><strong>\u529f\u80fd<\/strong><\/td>\n<td><strong>\u6280\u672f\u7279\u70b9<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u706b\u6392\uff08\u71c3\u70e7\u5668\uff09<\/strong><\/td>\n<td>\u5929\u7136\u6c14\u5728\u6b64\u70b9\u706b\u71c3\u70e7<\/td>\n<td>\u9760\u71c3\u6c14\u538b\u529b\u901a\u8fc7\u55b7\u5634\u55b7\u5c04\uff0c\u5f15\u5c04\u5668\u5f15\u5165\u7ea650-60%\u4e00\u6b21\u7a7a\u6c14<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e3b\u6362\u70ed\u5668<\/strong><\/td>\n<td>\u91c7\u6696\u6c34\u4ece\u4e2d\u6d41\u8fc7\uff0c\u5438\u6536\u706b\u7130\u70ed\u91cf<\/td>\n<td>\u5355\u5c42\u5e73\u9762\u7fc5\u7247\u7ba1\uff0c\u6750\u8d28\u4e3a\u94dc<\/td>\n<\/tr>\n<tr>\n<td><strong>\u98ce\u673a<\/strong><\/td>\n<td>\u5438\u5165\u4e8c\u6b21\u7a7a\u6c14\uff0c\u6392\u51fa\u70df\u6c14<\/td>\n<td>\u7089\u8154\u5185\u4e3a\u8d1f\u538b\uff0c\u4e8c\u6b21\u7a7a\u6c14\u9760\u98ce\u673a\u5438\u5165<\/td>\n<\/tr>\n<tr>\n<td><strong>\u540c\u8f74\u70df\u9053<\/strong><\/td>\n<td>\u6392\u70df+\u8fdb\u6c14<\/td>\n<td>\u5957\u7ba1\u7ed3\u6784\uff0c\u5185\u7ba1\u6392\u70df\uff0c\u5916\u7ba1\u8fdb\u7a7a\u6c14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u71c3\u70e7\u8fc7\u7a0b<\/strong>\uff1a<\/p>\n<ol class=\"wp-block-list\">\n<li>\u5929\u7136\u6c14\u4ece\u706b\u6392\u55b7\u51fa\uff0c\u4e0e\u4e00\u6b21\u7a7a\u6c14\u90e8\u5206\u6df7\u5408\u540e\u71c3\u70e7\uff08\u706b\u7130\u8f83\u957f\u3001\u6e29\u5ea6\u8f83\u4f4e\uff09<\/li>\n<li>\u672a\u71c3\u5c3d\u7684\u71c3\u6c14\u5206\u5b50\u63a5\u89e6\u4e8c\u6b21\u7a7a\u6c14\u540e\u7ee7\u7eed\u71c3\u70e7<\/li>\n<li>\u9ad8\u6e29\u70df\u6c14\uff08700-1000\u2103\uff09\u5411\u4e0a\u6d41\u7ecf\u4e3b\u6362\u70ed\u5668\uff0c\u5c06\u70ed\u91cf\u4f20\u9012\u7ed9\u91c7\u6696\u6c34<\/li>\n<li>\u7ecf\u8fc7\u6362\u70ed\u5668\u540e\uff0c\u70df\u6c14\u6e29\u5ea6\u964d\u81f3110-200\u2103\uff0c\u88ab\u98ce\u673a\u62bd\u51fa\u6392\u8d70<\/li>\n<\/ol>\n<p class=\"wp-block-paragraph\"><strong>\u5927\u6c14\u5f0f\u71c3\u70e7\u7684\u4e09\u4e2a\u6548\u7387\u74f6\u9888<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u635f\u5931\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u5360\u6bd4<\/strong><\/td>\n<td><strong>\u7269\u7406\u539f\u7406<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6392\u70df\u70ed\u635f\u5931<\/strong><\/td>\n<td>\u7ea610%<\/td>\n<td>\u70df\u6c14110-200\u2103\u76f4\u63a5\u6392\u51fa\uff0c\u663e\u70ed\u88ab\u6d6a\u8d39<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c7d\u5316\u6f5c\u70ed\u635f\u5931<\/strong><\/td>\n<td>\u7ea610%<\/td>\n<td>\u5929\u7136\u6c14\u71c3\u70e7\u751f\u6210\u7684\u6c34\u84b8\u6c14\u4ee5\u6c14\u6001\u6392\u51fa\uff0c\u6f5c\u70ed\u65e0\u6cd5\u56de\u6536<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8fc7\u5269\u7a7a\u6c14\u635f\u5931<\/strong><\/td>\n<td>\u4f4e\u8d1f\u8377\u65f6\u52a0\u5267<\/td>\n<td>\u98ce\u673a\u98ce\u91cf\u4e0d\u53ef\u8c03\uff0c\u5c0f\u706b\u65f6\u7a7a\u6c14\u8fc7\u5269\u7cfb\u6570\u8fbe1.8-2.0\uff0c\u591a\u4f59\u7a7a\u6c14\u5e26\u8d70\u70ed\u91cf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u666e\u901a\u7089\u7406\u8bba\u6700\u9ad8\u6548\u7387\u7ea6<strong>80%<\/strong>\uff08\u6309\u771f\u5b9e\u9ad8\u70ed\u503c\u8ba1\u7b97\uff09\uff0c\u4f4e\u8d1f\u8377\u65f6\u6548\u7387\u4e25\u91cd\u8870\u51cf\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u666e\u901a\u7089\u7684\u81f4\u547d\u75db\u70b9\u2014\u2014\u4f4e\u6e29\u51b7\u51dd\u8150\u8680<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5f53\u56de\u6c34\u6e29\u5ea6&lt;60\u2103\u65f6\uff0c\u70df\u6c14\u6e29\u5ea6\u964d\u81f3\u9732\u70b9\uff08\u7ea655\u2103\uff09\u4ee5\u4e0b<\/li>\n<li>\u4ea7\u751f\u9178\u6027\u51b7\u51dd\u6c34\uff08\u78b3\u9178+\u4e9a\u786b\u9178\uff09<\/li>\n<li>\u8150\u8680\u94dc\u5236\u6362\u70ed\u5668\u548c\u6587\u4e18\u91cc\u7ba1\u53d6\u6837\u53e3<\/li>\n<li>\u5bfc\u81f4\u98ce\u538b\u6545\u969c\u3001\u6362\u70ed\u5668\u7a7f\u5b54\u6f0f\u6c34<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>1.1.2 \u51b7\u51dd\u7089\uff08\u5168\u9884\u6df7\u71c3\u70e7\uff09\u7684\u6280\u672f\u7a81\u7834<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u51b7\u51dd\u7089\u91c7\u7528<strong>\u5168\u9884\u6df7\u71c3\u70e7<\/strong>\u6280\u672f\uff0c\u5728\u71c3\u70e7\u524d\u5c06\u71c3\u6c14\u4e0e\u6240\u9700\u7a7a\u6c14\u6309\u6700\u4f73\u6bd4\u4f8b\uff08\u7a7a\u6c14\u8fc7\u5269\u7cfb\u65701.05-1.1\uff09\u5145\u5206\u6df7\u5408\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u666e\u901a\u7089\uff08\u5927\u6c14\u5f0f\uff09<\/strong><\/td>\n<td><strong>\u51b7\u51dd\u7089\uff08\u5168\u9884\u6df7\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u70e7\u65b9\u5f0f<\/td>\n<td>\u90e8\u5206\u9884\u6df7\uff0c\u4e8c\u6b21\u7a7a\u6c14\u8865\u5145<\/td>\n<td><strong>\u5168\u9884\u6df7<\/strong>\uff0c\u71c3\u70e7\u524d\u5df2\u5145\u5206\u6df7\u5408<\/td>\n<\/tr>\n<tr>\n<td>\u706b\u7130\u7279\u5f81<\/td>\n<td>\u706b\u7130\u957f\uff08\u7ea6120mm\uff09\u3001\u6e29\u5ea6\u8f83\u4f4e<\/td>\n<td>\u706b\u7130\u77ed\uff0835-40mm\uff09\u3001\u6e29\u5ea6\u6781\u9ad8<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u8fc7\u5269\u7cfb\u6570<\/td>\n<td>\u4f4e\u8d1f\u8377\u65f61.8-2.0<\/td>\n<td>\u5168\u5de5\u51b51.05-1.1<\/td>\n<\/tr>\n<tr>\n<td>\u7089\u8154\u538b\u529b<\/td>\n<td>\u8d1f\u538b<\/td>\n<td>\u6b63\u538b\uff08\u70ed\u8d28\u70b9\u5bc6\u5ea6\u5927\uff0c\u6362\u70ed\u6548\u7387\u9ad8\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6392\u70df\u6e29\u5ea6<\/td>\n<td>110-200\u2103<\/td>\n<td><strong>30-50\u2103<\/strong>\uff08\u8fbe\u5230\u9732\u70b9\u4ee5\u4e0b\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6f5c\u70ed\u56de\u6536<\/td>\n<td>\u274c \u65e0\u6cd5\u56de\u6536<\/td>\n<td>\u2705 <strong>\u56de\u6536\u6c7d\u5316\u6f5c\u70ed<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6362\u70ed\u5668\u6750\u8d28<\/td>\n<td>\u94dc\uff08\u4e0d\u8010\u9178\u8680\uff09<\/td>\n<td><strong>\u4e0d\u9508\u94a2\/\u7845\u94dd<\/strong>\uff08\u8010\u9178\u6027\u51b7\u51dd\u6c34\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/td>\n<td>8-10kW<\/td>\n<td><strong>3-4kW<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u51b7\u51dd\u7089\u8282\u80fd\u7684\u4e09\u5927\u6765\u6e90<\/strong>\uff1a<\/p>\n<ol class=\"wp-block-list\">\n<li><strong>\u51b7\u51dd\u70ed\u56de\u6536<\/strong>\uff1a\u6392\u70df\u6e29\u5ea6\u964d\u81f3\u9732\u70b9\u4ee5\u4e0b\uff0c\u6c34\u84b8\u6c14\u51b7\u51dd\u91ca\u653e\u6f5c\u70ed\uff0c\u6548\u7387\u63d0\u5347\u7ea610-15%<\/li>\n<li><strong>\u5168\u9884\u6df7\u71c3\u70e7<\/strong>\uff1a\u7a7a\u6c14\u8fc7\u5269\u7cfb\u6570\u6781\u5c0f\uff0c\u51cf\u5c11\u6392\u70df\u70ed\u635f\u5931<\/li>\n<li><strong>\u5168\u5c01\u95ed\u71c3\u70e7<\/strong>\uff1a\u706b\u7130\u5468\u56f4\u5168\u662f\u6362\u70ed\u5668\uff0c\u51cf\u5c11\u7089\u4f53\u6563\u70ed<\/li>\n<\/ol>\n<p class=\"wp-block-paragraph\"><strong>1.1.3 \u70ed\u6548\u7387\u6807\u6ce8\u7684\u771f\u76f8\uff1a\u4e3a\u4ec0\u4e48\u51b7\u51dd\u7089\u80fd\u8d85\u8fc7100%\uff1f<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f <strong>\u91cd\u8981\u77e5\u8bc6\u70b9\uff1a108%\u70ed\u6548\u7387\u2260\u8fdd\u53cd\u80fd\u91cf\u5b88\u6052\u5b9a\u5f8b<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6982\u5ff5<\/strong><\/td>\n<td><strong>\u5b9a\u4e49<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u9ad8\u4f4d\u70ed\u503c\uff08HHV\uff09<\/strong><\/td>\n<td>\u5929\u7136\u6c14\u5b8c\u5168\u71c3\u70e7\u91ca\u653e\u7684<strong>\u603b\u70ed\u91cf<\/strong>\uff08\u542b\u6f5c\u70ed\uff09<\/td>\n<td>\u771f\u5b9e\u7684\u70ed\u80fd\u603b\u91cf<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4f4e\u4f4d\u70ed\u503c\uff08LHV\uff09<\/strong><\/td>\n<td>\u9ad8\u4f4d\u70ed\u503c\u51cf\u53bb\u6c34\u84b8\u6c14\u6c7d\u5316\u6f5c\u70ed\uff08\u7ea610-11%\uff09<\/td>\n<td><strong>\u884c\u4e1a\u901a\u7528\u7684\u8ba1\u7b97\u57fa\u51c6<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c7d\u5316\u6f5c\u70ed<\/strong><\/td>\n<td>\u6c34\u84b8\u6c14\u4ece\u6c14\u6001\u53d8\u4e3a\u6db2\u6001\u65f6\u91ca\u653e\u7684\u70ed\u91cf<\/td>\n<td>\u666e\u901a\u7089\u65e0\u6cd5\u5229\u7528\uff0c\u51b7\u51dd\u7089\u53ef\u56de\u6536<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6548\u7387\u6362\u7b97\u516c\u5f0f<\/strong>\uff1a<strong>\u771f\u5b9e\u6548\u7387 \u2248 \u6807\u79f0\u6548\u7387 \u00d7 0.9<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7089\u578b<\/strong><\/td>\n<td><strong>\u6807\u79f0\u6548\u7387\uff08\u6309LHV\uff09<\/strong><\/td>\n<td><strong>\u771f\u5b9e\u6548\u7387\uff08\u6309HHV\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u7089\uff08\u4e8c\u7ea7\u80fd\u6548\uff09<\/td>\n<td>89-93%<\/td>\n<td><strong>80-84%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51dd\u7089\uff08\u4e00\u7ea7\u80fd\u6548\uff09<\/td>\n<td>103-108%<\/td>\n<td><strong>93-97%<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7269\u7406\u672c\u8d28<\/strong>\uff1a\u51b7\u51dd\u7089\u591a\u56de\u6536\u4e86\u7ea610-11%\u7684\u6c7d\u5316\u6f5c\u70ed\uff0c\u56e0\u6b64\u5728\u4ee5\u4f4e\u70ed\u503c\u4e3a\u57fa\u51c6\u65f6\uff0c\u6548\u7387\u53ef\u8fbe108%\u3002\u4f46\u6309\u771f\u5b9e\u7684\u9ad8\u4f4d\u70ed\u503c\u8ba1\u7b97\uff0c<strong>\u6c38\u8fdc\u4e0d\u8d85\u8fc7100%<\/strong>\uff0c\u5b8c\u5168\u9075\u5b88\u80fd\u91cf\u5b88\u6052\u5b9a\u5f8b\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>1.1.4 \u51b7\u51dd\u7089\u7684\u201c\u5751\u201d\uff1a\u4e0d\u80fd\u4f4e\u6e29\u8fd0\u884c\u7b49\u4e8e\u767d\u4e70<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u51b7\u51dd\u7089\u8282\u80fd\u7684\u524d\u63d0\u662f<strong>\u4f4e\u56de\u6c34\u6e29\u5ea6<\/strong>\u2014\u2014\u56de\u6c34\u538b\u5230 50\u2103 \u4ee5\u4e0b\u624d\u9ad8\u6548\u51b7\u51dd\uff0c\u56de\u6c34\u5230 55\u2103 \u5de6\u53f3\u51b7\u51dd\u57fa\u672c\u505c\u6b62\u3002\u5982\u679c\u914d\u666e\u901a\u6696\u6c14\u7247\uff08\u9700\u898170-80\u2103\u6c34\u6e29\u3001\u56de\u6c34\u538b\u4e0d\u4e0b\u6765\uff09\uff0c\u51b7\u51dd\u7089\u65e0\u6cd5\u8fdb\u5165\u51b7\u51dd\u5de5\u51b5\uff0c\u6392\u70df\u6e29\u5ea6\u964d\u4e0d\u4e0b\u6765\uff0c\u6f5c\u70ed\u65e0\u6cd5\u56de\u6536\uff0c\u5b9e\u9645\u6548\u7387\u53ea\u6bd4\u666e\u901a\u7089\u9ad83-5%\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8bef\u533a<\/strong><\/td>\n<td><strong>\u771f\u76f8<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e70\u4e86\u51b7\u51dd\u7089\u5c31\u4e00\u5b9a\u8282\u80fd<\/td>\n<td>\u5fc5\u987b\u914d\u5408\u4f4e\u6e29\u672b\u7aef\uff08\u5730\u6696\u6216\u4f4e\u6e29\u6696\u6c14\u7247\uff09\u624d\u80fd\u53d1\u6325\u8282\u80fd\u4f18\u52bf<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51dd\u7089\u914d\u666e\u901a\u6696\u6c14\u7247\u4e5f\u80fd\u7701\u6c14<\/td>\n<td>\u666e\u901a\u6696\u6c14\u7247\u9700\u898170-80\u2103\u6c34\u6e29\uff0c\u51b7\u51dd\u7089\u65e0\u6cd5\u8fdb\u5165\u51b7\u51dd\u5de5\u51b5<\/td>\n<\/tr>\n<tr>\n<td>\u6d41\u91cf\u4e0d\u591f\uff0c\u6c34\u6e29\u6765\u51d1<\/td>\n<td>\u7ba1\u8def\u8bbe\u8ba1\u4e0d\u5f53\u2192\u6d41\u91cf\u4e0d\u8db3\u2192\u88ab\u8feb\u63d0\u9ad8\u6c34\u6e29\u2192\u51b7\u51dd\u529f\u80fd\u5931\u6548<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u4e3a\u4ec0\u4e48\u8fd9\u4e2a\u5751\u4e0d\u5bb9\u6613\u88ab\u53d1\u73b0\uff1f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u8f66\u5b50\u9a6c\u529b\u4e0d\u597d\uff0c\u4f60\u8e29\u6cb9\u95e8\u5c31\u611f\u53d7\u5230\u4e86<\/li>\n<li>\u51b7\u51dd\u7089\u4e0d\u8282\u80fd\uff0c<strong>\u4f60\u611f\u53d7\u4e0d\u5230<\/strong>\u2014\u2014\u623f\u95f4\u7167\u6837\u70ed\uff0c\u4f46\u71c3\u6c14\u8d39\u6084\u6084\u5730\u591a\u82b1\u4e86<\/li>\n<li>\u552f\u4e00\u76f4\u89c2\u7684\u5224\u65ad\u6807\u51c6\uff1a<strong>\u770b\u6c34\u6e29<\/strong><\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u81ea\u67e5\u65b9\u6cd5<\/strong>\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u60a8\u53ea\u9700\u8981\u770b\u4e00\u773c\u9505\u7089\u9762\u677f\u4e0a\u7684\u4f9b\u6c34\u6e29\u5ea6\u3002\u5982\u679c\u6574\u4e2a\u51ac\u5929\u5927\u90e8\u5206\u65f6\u95f4\u572855\u2103\u4ee5\u4e0a\u8fd0\u884c\uff0c\u751a\u81f360\u2103\u4ee5\u4e0a\u5ba4\u5185\u624d\u80fd\u70ed\u8d77\u6765\u2014\u2014\u60a8\u7684\u51b7\u51dd\u7089\u767d\u4e70\u4e86\uff0c\u5b83\u4e00\u76f4\u5728\u5f53\u666e\u901a\u7089\u7528\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u51b7\u51dd\u7089\u9002\u914d\u6761\u4ef6<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u672b\u7aef\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u4f9b\u6c34\u6e29\u5ea6<\/strong><\/td>\n<td><strong>\u662f\u5426\u53d1\u6325\u51b7\u51dd\u4f18\u52bf<\/strong><\/td>\n<td><strong>\u5efa\u8bae<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u7cfb\u7edf<\/td>\n<td>35-45\u2103<\/td>\n<td>\u2705 \u6700\u4f73\u642d\u6863<\/td>\n<td>\u9996\u9009\u51b7\u51dd\u7089<\/td>\n<\/tr>\n<tr>\n<td>\u4f4e\u6e29\u6696\u6c14\u7247<\/td>\n<td>50-55\u2103<\/td>\n<td>\u2705 \u53ef\u9002\u914d<\/td>\n<td>\u9700\u52a0\u5927\u7247\u657030-50%<\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u6696\u6c14\u7247<\/td>\n<td>70-80\u2103<\/td>\n<td>\u274c \u65e0\u6cd5\u51b7\u51dd<\/td>\n<td>\u4e0d\u5982\u4e70\u666e\u901a\u7089<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">1.2 \u672b\u7aef\u7cfb\u7edf\u7684\u6f14\u8fdb\uff1a\u5730\u6696\u4e0e\u6696\u6c14\u7247<\/h3>\n<p class=\"wp-block-paragraph\"><strong>1.2.1 \u5730\u6696\uff08\u4f4e\u6e29\u8f90\u5c04\u7cfb\u7edf\uff09<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7279\u6027<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5de5\u4f5c\u539f\u7406<\/td>\n<td>\u4f4e\u6e29\u70ed\u6c34\uff0835-55\u2103\uff09\u5728\u57cb\u5730\u7ba1\u9053\u4e2d\u5faa\u73af\uff0c\u4ee5\u8f90\u5c04\u65b9\u5f0f\u5411\u5ba4\u5185\u6563\u70ed<\/td>\n<\/tr>\n<tr>\n<td>\u6838\u5fc3\u4f18\u52bf<\/td>\n<td>\u8212\u9002\u5ea6\u9ad8\uff08\u6e29\u8db3\u51c9\u9876\uff09\u3001\u4e0d\u5360\u7a7a\u95f4\u3001\u70ed\u7a33\u5b9a\u6027\u597d\uff08\u56de\u586b\u5c42\u84c4\u70ed\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u5173\u952e<\/td>\n<td>\u6c34\u529b\u5e73\u8861\uff08\u540c\u7a0b\/\u5206\u96c6\u6c34\u5668\uff09\u3001\u5206\u5ba4\u63a7\u5236\u3001\u963b\u6c27\u7ba1\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td>\u89c4\u8303\u4f9d\u636e<\/td>\n<td>JGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u542f\u52a8\u901f\u5ea6<\/td>\n<td><strong>\u6162<\/strong>\uff08\u521d\u6b21\u52a0\u70ed\u97008-12\u5c0f\u65f6\uff09\uff0c\u9002\u5b9c\u8fde\u7eed\u4f9b\u6696<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>1.2.2 \u6696\u6c14\u7247\uff08\u9ad8\u6e29\u5bf9\u6d41\u7cfb\u7edf\uff09<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7279\u6027<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5de5\u4f5c\u539f\u7406<\/td>\n<td>\u8f83\u9ad8\u6e29\u70ed\u6c34\uff0870-80\u2103\uff09\u5728\u6696\u6c14\u7247\u5185\u5faa\u73af\uff0c\u4ee5\u5bf9\u6d41\u548c\u8f90\u5c04\u52a0\u70ed\u7a7a\u6c14<\/td>\n<\/tr>\n<tr>\n<td>\u6838\u5fc3\u4f18\u52bf<\/td>\n<td>\u5347\u6e29\u8fc5\u901f\uff0815-30\u5206\u949f\uff09\u3001\u5373\u5f00\u5373\u7528\u3001\u53ef\u660e\u88c5\u6539\u9020\u3001\u5bf9\u5c42\u9ad8\u65e0\u8981\u6c42<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u5173\u952e<\/td>\n<td>\u9009\u578b\u5339\u914d\uff08\u6563\u70ed\u91cfvs\u70ed\u8d1f\u8377\uff09\u3001\u6c34\u529b\u5e73\u8861\uff08\u540c\u7a0b\/\u5f02\u7a0b\uff09\u3001\u6e29\u63a7\u9600<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u542f\u52a8\u901f\u5ea6<\/td>\n<td><strong>\u5feb<\/strong>\uff0c\u9002\u5b9c\u95f4\u6b47\u4f9b\u6696<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>1.2.3 \u6696\u6c14\u7247\u6563\u70ed\u91cf\u516c\u5f0f\u4e0e\u4f4e\u6e29\u6696\u6c14\u7247\u539f\u7406<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Q = K \u00d7 F \u00d7 \u0394T<\/strong><\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\">\u5176\u4e2d\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>Q\uff1a\u6563\u70ed\u91cf\uff08W\uff09<\/li>\n<li>K\uff1a\u6696\u6c14\u7247\u4f20\u70ed\u7cfb\u6570<\/li>\n<li>F\uff1a\u6696\u6c14\u7247\u6563\u70ed\u9762\u79ef<\/li>\n<li>\u0394T\uff1a\u4f9b\u56de\u6c34\u5e73\u5747\u6e29\u5ea6\u4e0e\u5ba4\u6e29\u7684\u5dee\u503c<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5173\u952e\u7ed3\u8bba<\/strong>\uff1a\u5728Q\u3001K\u4e0d\u53d8\u7684\u60c5\u51b5\u4e0b\uff0c<strong>\u589e\u5927F\uff08\u589e\u52a0\u6696\u6c14\u7247\u6570\u91cf\uff09\uff0c\u5c31\u53ef\u4ee5\u964d\u4f4e\u0394T\uff08\u5373\u964d\u4f4e\u58c1\u6302\u7089\u51fa\u6c34\u6e29\u5ea6\uff09<\/strong>\u3002\u8fd9\u5c31\u662f<strong>\u4f4e\u6e29\u6696\u6c14\u7247<\/strong>\u7684\u7269\u7406\u539f\u7406\u2014\u2014\u901a\u8fc7\u589e\u52a0\u6696\u6c14\u7247\u6570\u91cf\u6216\u8868\u9762\u79ef\uff0c\u4f7f\u7cfb\u7edf\u572850-55\u2103\u4f4e\u6e29\u4e0b\u4ecd\u80fd\u8fbe\u5230\u8bbe\u8ba1\u6563\u70ed\u91cf\uff0c\u4ece\u800c\u53d1\u6325\u51b7\u51dd\u7089\u7684\u4f4e\u6e29\u9ad8\u6548\u4f18\u52bf\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>1.2.4 \u5730\u6696\u4e0e\u6696\u6c14\u7247\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u5730\u6696<\/strong><\/td>\n<td><strong>\u6696\u6c14\u7247<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7a7a\u95f4<\/strong><\/td>\n<td>\u5360\u5c42\u9ad8\uff085-8cm\uff09<\/td>\n<td>\u5360\u5ba4\u5185\u5899\u9762\u7a7a\u95f4<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4ef7\u683c<\/strong><\/td>\n<td>\u8f83\u9ad8\uff08\u9700\u56de\u586b\uff09<\/td>\n<td>\u8f83\u4f4e<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8212\u9002\u5ea6<\/strong><\/td>\n<td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u8f90\u5c04\u4f9b\u6696\uff0c\u6e29\u8db3\u51c9\u9876<\/td>\n<td>\u2b50\u2b50\u2b50 \u5bf9\u6d41\u4f9b\u6696\uff0c\u8212\u9002\u5ea6\u4e00\u822c<\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u542f\u52a8\u901f\u5ea6<\/strong><\/td>\n<td>\u6162\uff088-12\u5c0f\u65f6\uff09<\/td>\n<td>\u5feb\uff0815-30\u5206\u949f\uff09<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ef4\u4fdd<\/strong><\/td>\n<td>\u76d8\u7ba1\u4e0e\u5efa\u7b51\u540c\u5bff\u547d<\/td>\n<td>8-10\u5e74\u9700\u7ef4\u62a4\u6216\u66f4\u6362<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8282\u80fd\u6027<\/strong><\/td>\n<td>\u5168\u5f00\u65f6\u66f4\u8282\u80fd<\/td>\n<td>\u95f4\u6b47\u4f7f\u7528\u65f6\u66f4\u7075\u6d3b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e8c\u90e8\u5206\uff1a\u7cfb\u7edf\u67b6\u6784\u4e0e\u8bbe\u8ba1\u89c4\u8303<\/h2>\n<h3 class=\"wp-block-heading\">2.0 \u9f99\u8109\u6696\u901a\u00b7\u91c7\u6696\u7cfb\u7edf\u8bbe\u8ba1\u54f2\u5b66<\/h3>\n<p class=\"wp-block-paragraph\"><strong>2.0.1 \u6838\u5fc3\u7406\u5ff5\uff1a\u7cfb\u7edf\u56db\u8981\u7d20\u5339\u914d<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u4efb\u4f55\u4e00\u5957\u5b8c\u6574\u7684\u91c7\u6696\u7cfb\u7edf\uff0c\u90fd\u7531\u56db\u4e2a\u8981\u7d20\u6784\u6210\u3002\u8fd9\u56db\u4e2a\u8981\u7d20\u5fc5\u987b<strong>\u5b8c\u5168\u5339\u914d<\/strong>\uff0c\u7f3a\u4e00\u4e0d\u53ef\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8981\u7d20<\/strong><\/td>\n<td><strong>\u6696\u901a\u5bf9\u5e94<\/strong><\/td>\n<td><strong>\u6846\u67b6\u5bf9\u5e94<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u95ee\u9898<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u6e90<\/strong><\/td>\n<td>\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd<\/td>\n<td>\u4f9b\u7ed9\u4fa7\uff08\u4ea7\u70ed\uff09<\/td>\n<td>\u4ea7\u7684\u70ed\u591f\u4e0d\u591f\uff1f\u4f1a\u4e0d\u4f1a\u4ea7\u592a\u591a\uff1f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8f93\u914d<\/strong><\/td>\n<td>\u7ba1\u9053\u3001\u6c34\u6cf5\u3001\u5206\u96c6\u6c34\u5668<\/td>\n<td>\u7269\u6d41\uff08\u8fd0\u70ed\uff09<\/td>\n<td>\u4ea7\u7684\u70ed\u80fd\u4e0d\u80fd\u5168\u90e8\u62c9\u8d70\uff1f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u672b\u7aef<\/strong><\/td>\n<td>\u5730\u6696\u76d8\u7ba1\/\u6696\u6c14\u7247<\/td>\n<td>\u6d88\u8d39\u4fa7\uff08\u7528\u70ed\uff09<\/td>\n<td>\u62c9\u6765\u7684\u70ed\u80fd\u4e0d\u80fd\u5168\u90e8\u6563\u6389\uff1f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u63a7\u5236<\/strong><\/td>\n<td>\u6e29\u63a7\u5668\u3001\u8054\u52a8\u7cfb\u7edf<\/td>\n<td>\u4f9b\u9700\u5339\u914d<\/td>\n<td>\u4ec0\u4e48\u65f6\u5019\u8be5\u4ea7\u3001\u4ec0\u4e48\u65f6\u5019\u8be5\u505c\uff1f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd<\/strong>\uff1a\u4ea7\u7684\u70ed\u62c9\u4e0d\u8d70\uff0c\u70ed\u6e90\u81ea\u635f\uff1b\u62c9\u6765\u7684\u70ed\u6563\u4e0d\u6389\uff0c\u5bb6\u91cc\u4e0d\u70ed\u3002<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>2.0.2 \u4f9b\u7ed9\u4fa7\uff08\u70ed\u6e90\uff09\uff1a\u529f\u7387\u5339\u914d\u662f\u7b2c\u4e00\u539f\u5219<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u4f20\u7edf\u58c1\u6302\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u73878-10kW\uff0c\u4f46100\u33a1\u5730\u6696\u6052\u6e29\u4ec5\u97005kW\u3002\u529f\u7387\u8fc7\u5269\u5bfc\u81f4\uff1a<\/p>\n<pre class=\"wp-block-code\"><code>\u70b9\u706b\uff0824kW\u6ee1\u529f\u7387\uff09\u2192 \u6c34\u6e29\u5feb\u901f\u8fbe\u6807 \u2192 \u505c\u673a\n\u2192 \u98ce\u673a\u540e\u5439\u626b+\u5438\u5165\u51b7\u7a7a\u6c14 \u2192 \u6c34\u6e29\u9aa4\u964d \u2192 \u518d\u6b21\u70b9\u706b\n\u2192 \u6076\u6027\u5faa\u73af\uff0c\u71c3\u6c14\u6d6a\u8d3920-30%\n<\/code><\/pre>\n<p class=\"wp-block-paragraph\"><strong>\u9009\u578b\u4e09\u539f\u5219<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u539f\u5219<\/strong><\/td>\n<td><strong>\u5185\u5bb9<\/strong><\/td>\n<td><strong>\u5ba2\u6237\u4ef7\u503c<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6700\u5927\u529f\u7387\u5339\u914d<\/strong><\/td>\n<td>\u6ee1\u8db3\u5ba4\u5185\u6700\u5927\u70ed\u8d1f\u8377<\/td>\n<td>\u6700\u51b7\u5929\u4e5f\u80fd\u70ed\u8d77\u6765<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6700\u5c0f\u529f\u7387\u5339\u914d<\/strong><\/td>\n<td>\u4f4e\u4e8e\u5ba4\u5185\u6700\u5c0f\u70ed\u9700\u6c42<\/td>\n<td>\u907f\u514d\u9891\u7e41\u542f\u505c<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e0d\u8d85\u914d<\/strong><\/td>\n<td>\u4e0d\u76f2\u76ee\u8ffd\u6c42\u5927\u529f\u7387<\/td>\n<td>\u8282\u80fd\u7701\u6c14\uff0c\u5bff\u547d\u66f4\u957f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.0.3 \u7269\u6d41\uff08\u8f93\u914d\uff09\uff1a\u6c34\u529b\u5e73\u8861\u662f\u6838\u5fc3<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u7279\u70b9<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<td><strong>\u6c34\u529b\u5e73\u8861<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u53cc\u7ba1\u5f02\u7a0b<\/strong><\/td>\n<td>\u65bd\u5de5\u7b80\u5355\uff0c\u6210\u672c\u4f4e<\/td>\n<td>\u5c0f\u6237\u578b\u660e\u88c5\uff08\u226470\u33a1\uff09<\/td>\n<td>\u274c \u5dee<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5355\u7ba1\u7cfb\u7edf<\/strong><\/td>\n<td>H\u9600\u53ef\u8c03\uff0c\u6bcf\u7ec4\u72ec\u7acb\u63a7\u5236<\/td>\n<td>70-140\u33a1\u4e2d\u7b49\u6237\u578b<\/td>\n<td>\u26a0\ufe0f \u4e2d\u7b49<\/td>\n<\/tr>\n<tr>\n<td><strong>\u540c\u7a0b\u7cfb\u7edf<\/strong><\/td>\n<td>\u5404\u652f\u8def\u7ba1\u957f\u76f8\u7b49<\/td>\n<td>\u5730\u6696\u3001\u6697\u88c5\u6696\u6c14\u7247<\/td>\n<td>\u2705 \u597d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ae0\u9c7c\u5f0f\uff08\u5206\u96c6\u6c34\u5668\uff09<\/strong><\/td>\n<td>\u72ec\u7acb\u5f15\u51fa\u5404\u652f\u8def<\/td>\n<td>\u6697\u88c5\u5730\u6696\/\u6696\u6c14\u7247\u9996\u9009<\/td>\n<td>\u2705 \u6700\u4f18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.0.4 \u6d88\u8d39\u4fa7\uff08\u672b\u7aef\uff09\uff1a\u6696\u6c14\u7247\u591a\u7ef4\u5ea6\u5bf9\u6bd4<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u3001\u6696\u6c14\u7247\u7c7b\u578b\u5bf9\u6bd4<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u6563\u70ed\u539f\u7406<\/strong><\/td>\n<td><strong>\u7279\u70b9<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u94a2\u5236\u677f\u5f0f<\/strong><\/td>\n<td>\u8f90\u5c04+\u5bf9\u6d41<\/td>\n<td>\u5347\u6e29\u5feb\u3001\u710a\u70b9\u5c11\u3001\u6f0f\u6c34\u98ce\u9669\u4f4e<\/td>\n<td>\u666e\u901a\u4f4f\u5b85\u3001\u5feb\u901f\u5347\u6e29<\/td>\n<\/tr>\n<tr>\n<td><strong>\u94a2\u5236\u67f1\u5f0f<\/strong><\/td>\n<td>\u5bf9\u6d41\u4e3a\u4e3b<\/td>\n<td>\u50a8\u6c34\u91cf\u5927\u3001\u4fdd\u6e29\u597d\u3001\u53ef\u5b9a\u5236<\/td>\n<td>\u5927\u9762\u79ef\u7a7a\u95f4\u3001\u6311\u9ad8\u5ba2\u5385<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4f4e\u6e29\u6696\u6c14\u7247<\/strong><\/td>\n<td>\u52a0\u5927\u9762\u79ef\u8865\u507f\u4f4e\u6e29<\/td>\n<td>\u9002\u914d\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd<\/td>\n<td>\u4f4e\u6e29\u4f9b\u6696\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td><strong>\u94dc\u94dd\u590d\u5408<\/strong><\/td>\n<td>\u8f90\u5c04+\u5bf9\u6d41<\/td>\n<td>\u5bfc\u70ed\u5feb\u3001\u8010\u8150\u8680<\/td>\n<td>\u6c34\u8d28\u8f83\u5dee\u5730\u533a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u4e8c\u3001\u6696\u6c14\u7247\u9ad8\u5ea6\u9009\u62e9<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9ad8\u5ea6\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u6563\u70ed\u539f\u7406<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<td><strong>\u6ce8\u610f\u4e8b\u9879<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u9ad8\u7247\uff081.5-1.8m\uff09<\/strong><\/td>\n<td>\u5f3a\u5316\u201c\u70ed\u70df\u56f1\u6548\u5e94\u201d\uff0c\u5bf9\u6d41\u5f3a\u52b2<\/td>\n<td>\u5899\u9762\u7a84\u5c0f\u3001\u5feb\u901f\u6574\u4f53\u5347\u6e29<\/td>\n<td>\u6311\u9ad8\u7a7a\u95f4\u6613\u201c\u5934\u70ed\u811a\u51c9\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u77ee\u7247\uff08300-600mm\uff09<\/strong><\/td>\n<td>\u70ed\u8f90\u5c04\u66f4\u5f3a\uff0c\u4f53\u611f\u8212\u9002<\/td>\n<td>\u5927\u7a97\u6237\/\u843d\u5730\u7a97\u3001\u8ffd\u6c42\u8212\u9002<\/td>\n<td>\u6574\u4f53\u5347\u6e29\u7a0d\u6162<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8e22\u811a\u7ebf\u5f0f<\/strong><\/td>\n<td>\u6cbf\u5899\u5e95\u90e8\u5bf9\u6d41<\/td>\n<td>\u5c0f\u6237\u578b\u3001\u6781\u7b80\u98ce\u683c<\/td>\n<td>\u5355\u7ec4\u529f\u7387\u4f4e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u7279\u522b\u63d0\u793a<\/strong>\uff1a\u67f1\u5f0f\u6696\u6c14\u7247\uff08\u9ad8\u7247\uff09\u9002\u5408\u522b\u5885\u3001\u6311\u9ad8\u5ba2\u5385\u3001\u590d\u5f0f\u8dc3\u5c42\u3001\u6709\u697c\u68af\u7684\u6d0b\u623f\u3002\u539f\u56e0\uff1a\u8fd9\u4e9b\u7a7a\u95f4\u7684\u70ed\u7a7a\u6c14\u5bb9\u6613\u88ab\u201c\u70df\u56f1\u6548\u5e94\u201d\u62bd\u8d70\uff0c\u800c\u67f1\u5f0f\u6696\u6c14\u7247\u7684\u8f90\u5c04\u6563\u70ed\u53ef\u4ee5\u907f\u514d\u5bf9\u6d41\u5f0f\u70ed\u6c14\u88ab\u62bd\u8d70\u3002<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u4e09\u3001\u6696\u6c14\u7247\u4e0e\u70ed\u6e90\u5339\u914d<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u70ed\u6e90\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u4f9b\u6c34\u6e29\u5ea6<\/strong><\/td>\n<td><strong>\u63a8\u8350\u6696\u6c14\u7247<\/strong><\/td>\n<td><strong>\u9009\u578b\u8c03\u6574<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u58c1\u6302\u7089<\/td>\n<td>70-80\u2103<\/td>\n<td>\u94a2\u5236\u677f\u5f0f\/\u67f1\u5f0f<\/td>\n<td>\u6807\u51c6\u914d\u7f6e<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51dd\u58c1\u6302\u7089<\/td>\n<td>50-60\u2103<\/td>\n<td><strong>\u4f4e\u6e29\u6696\u6c14\u7247<\/strong><\/td>\n<td>\u589e\u52a0\u7247\u657030-50%<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u6e90\u70ed\u6cf5<\/td>\n<td>40-55\u2103<\/td>\n<td><strong>\u4f4e\u6e29\u6696\u6c14\u7247<\/strong><\/td>\n<td>\u9700\u589e\u5927\u6563\u70ed\u9762\u79ef<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.0.5 \u63a7\u5236\u8054\u52a8\uff1a\u5ba4\u6e29\u662f\u6700\u7ec8\u76ee\u6807<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6c34\u6e29\u63a7\u5236 vs \u5ba4\u6e29\u63a7\u5236<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u63a7\u5236\u65b9\u5f0f<\/strong><\/td>\n<td><strong>\u58c1\u6302\u7089\/\u4e3b\u673a<\/strong><\/td>\n<td><strong>\u672b\u7aef<\/strong><\/td>\n<td><strong>\u95ee\u9898<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u6e29\u63a7\u5236<\/strong><\/td>\n<td>\u6309\u6c34\u6e29\u542f\u505c<\/td>\n<td>\u5ba4\u6e29\u8fbe\u6807\u4f46\u9505\u7089\u7ee7\u7eed\u70e7<\/td>\n<td>\u65e0\u6548\u4ea7\u70ed<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5ba4\u6e29\u63a7\u5236<\/strong><\/td>\n<td>\u6309\u5ba4\u6e29\u542f\u505c<\/td>\n<td>\u5ba4\u6e29\u8fbe\u6807\u540e\u9505\u7089\u505c\u673a<\/td>\n<td>\u6309\u9700\u4f9b\u70ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8054\u52a8\u63a7\u5236\u7684\u6b63\u786e\u903b\u8f91<\/strong>\uff1a<\/p>\n<pre class=\"wp-block-code\"><code>\u5ba4\u6e29\u4f20\u611f\u5668\u68c0\u6d4b \u2192 \u5ba4\u6e29\u4f4e\u4e8e\u8bbe\u5b9a \u2192 \u8054\u52a8\u542f\u52a8\u6c34\u6cf5 \u2192 \u8054\u52a8\u542f\u52a8\u9505\u7089 \u2192 \u70ed\u6c34\u5faa\u73af \u2192 \u5ba4\u6e29\u8fbe\u6807 \u2192 \u8054\u52a8\u505c\u673a\n<\/code><\/pre>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u96be\u70b9<\/strong>\uff1a\u6c34\u7cfb\u7edf\u3001\u5730\u6696\u548c\u6696\u6c14\u7247\u7cfb\u7edf\u90fd\u662f\u5404\u79cd\u54c1\u724c\u96c6\u6210\u5316\u7684\u7cfb\u7edf\u3002\u975e\u4e13\u4e1a\u6027\u7684\u670d\u52a1\u4f1a\u5bfc\u81f4\uff1a\u6c34\u6cf5\u4e0d\u8054\u52a8\uff0824\u5c0f\u65f6\u8f6c\uff09\u3001\u9505\u7089\u6309\u6c34\u6e29\u542f\u505c\uff08\u65e0\u6548\u4ea7\u70ed\uff09\u3001\u5ba4\u6e29\u8fbe\u6807\u4e86\u8fd8\u5728\u70e7\u3002<strong>\u8054\u52a8\u63a7\u5236\u662f\u6d89\u6c34\u7cfb\u7edf\u6700\u96be\u4e5f\u6700\u9700\u8981\u4e13\u4e1a\u5316\u8bbe\u8ba1\u7684\u73af\u8282\u3002<\/strong><\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>2.0.6 \u5c45\u5bb6\u73af\u5883\u9700\u6c42\u5c42\u6b21\u7406\u8bba\uff08\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u54f2\u5b66\uff09<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5b89\u5168\u2192\u57fa\u7840\u51b7\u6696\u2192\u5065\u5eb7\u8212\u9002\u2192\u8282\u80fd\u7701\u5fc3\u2192\u4e2a\u6027\u7f8e\u5b66<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5c42\u6b21<\/strong><\/td>\n<td><strong>\u540d\u79f0<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u95ee\u9898<\/strong><\/td>\n<td><strong>\u8bbe\u8ba1\u5bff\u547d<\/strong><\/td>\n<td><strong>\u6696\u901a\u5bf9\u5e94<\/strong><\/td>\n<td><strong>\u4e0d\u53ef\u59a5\u534f<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e00\u5c42<\/strong><\/td>\n<td>\u5b89\u5168<\/td>\n<td>\u4f1a\u4e0d\u4f1a\u6f0f\u7535\uff1f\u8d77\u706b\uff1f\u6f0f\u6c34\uff1f<\/td>\n<td>50-100\u5e74\uff08\u957f\u671f\uff09<\/td>\n<td>\u6c34\u7535\u5206\u79bb\u3001\u6f0f\u7535\u4fdd\u62a4\u3001\u4e09\u9053\u5bc6\u5c01<\/td>\n<td>\u2705 \u7edd\u5bf9\u4e0d\u53ef\u59a5\u534f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e8c\u5c42<\/strong><\/td>\n<td>\u57fa\u7840\u51b7\u6696<\/td>\n<td>\u51b7\u4e0d\u51b7\uff1f\u70ed\u4e0d\u70ed\uff1f\u7a33\u4e0d\u7a33\u5b9a\uff1f<\/td>\n<td>15\u5e74\u4ee5\u4e0a<\/td>\n<td>\u5236\u51b7\u5236\u70ed\u80fd\u529b\u3001\u7cfb\u7edf\u5339\u914d<\/td>\n<td>\u2705 \u529f\u80fd\u5fc5\u987b\u8fbe\u6807<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e09\u5c42<\/strong><\/td>\n<td>\u5065\u5eb7\u8212\u9002<\/td>\n<td>\u7a7a\u6c14\u5e72\u51c0\u5417\uff1f\u95f7\u5417\uff1f\u5439\u98ce\u5417\uff1f<\/td>\n<td>15\u5e74\u4ee5\u4e0a<\/td>\n<td>\u51c0\u5316\u3001\u6052\u6e7f\u3001\u6052\u6c27\u3001\u65e0\u98ce\u611f\u3001\u9759\u97f3<\/td>\n<td>\u53ef\u5206\u7ea7\u914d\u7f6e<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u56db\u5c42<\/strong><\/td>\n<td>\u8282\u80fd\u7701\u5fc3<\/td>\n<td>\u7701\u4e0d\u7701\u7535\uff1f\u7528\u4e0d\u7528\u4fee\uff1f<\/td>\n<td>15\u5e74\u4ee5\u4e0a\uff08\u6301\u7eed\u4ef7\u503c\uff09<\/td>\n<td>\u53d8\u9891\u6280\u672f\u3001\u8054\u52a8\u63a7\u5236\u3001\u4f4e\u6545\u969c<\/td>\n<td>\u53ef\u5206\u7ea7\u914d\u7f6e<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e94\u5c42<\/strong><\/td>\n<td>\u4e2a\u6027\u7f8e\u5b66<\/td>\n<td>\u597d\u770b\u5417\uff1f\u667a\u80fd\u5417\uff1f<\/td>\n<td>5-10\u5e74\uff08\u53ef\u66f4\u65b0\uff09<\/td>\n<td>\u5185\u673a\u9690\u85cf\u3001\u98ce\u53e3\u8bbe\u8ba1\u3001APP\u63a7\u5236<\/td>\n<td>\u53ef\u968f\u65f6\u66f4\u6362<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u539f\u5219<\/strong>\uff1a<strong>\u5fc5\u987b\u81ea\u4e0b\u800c\u4e0a\u8bbe\u8ba1\uff0c\u4e0d\u53ef\u672c\u672b\u5012\u7f6e\u3002<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>2.0.7 \u5e02\u573a\u56db\u5927\u4e71\u8c61\uff08\u91c7\u6696\u7cfb\u7edf\uff09<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4e71\u8c61<\/strong><\/td>\n<td><strong>\u8868\u73b0<\/strong><\/td>\n<td><strong>\u540e\u679c<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u529f\u7387\u4e25\u91cd\u8d85\u914d<\/strong><\/td>\n<td>\u76f2\u76ee\u63a8\u835024kW\u300128kW\u5927\u7089\uff0c\u4e0d\u8ba1\u7b97\u70ed\u8d1f\u8377<\/td>\n<td>\u9891\u7e41\u542f\u505c\uff0c\u80fd\u8017\u98d9\u5347<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7cfb\u7edf\u8bbe\u8ba1\u7b80\u5316<\/strong><\/td>\n<td>\u7528\u6700\u4fbf\u5b9c\u7684\u5f02\u7a0b\u7ba1\u8def\uff0c\u4e0d\u505a\u6c34\u529b\u5e73\u8861<\/td>\n<td>\u51b7\u70ed\u4e0d\u5747\uff0c\u6548\u679c\u5dee<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6750\u6599\u4ee5\u6b21\u5145\u597d<\/strong><\/td>\n<td>\u975e\u963b\u6c27\u7ba1\u3001\u52a3\u8d28\u9600\u95e8\u3001\u4f4e\u6807\u53f7\u4fdd\u6e29\u6750\u6599<\/td>\n<td>\u8150\u8680\u6f0f\u6c34\uff0c\u5bff\u547d\u77ed<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8054\u52a8\u63a7\u5236\u7f3a\u5931<\/strong><\/td>\n<td>\u4e0d\u505a\u5ba4\u6e29\u8054\u52a8\u3001\u6c34\u6cf524\u5c0f\u65f6\u8fd0\u8f6c<\/td>\n<td>\u7535\u8d39\u98d9\u5347\uff0c\u65e0\u6548\u4ea7\u70ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">2.1 \u70ed\u6e90\u9009\u578b\u539f\u5219<\/h3>\n<p class=\"wp-block-paragraph\"><strong>2.1.1 \u9505\u7089\u529f\u7387\u9009\u62e9<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9762\u79ef<\/strong><\/td>\n<td><strong>\u63a8\u8350\u529f\u7387<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u2264100\u33a1<\/td>\n<td>18-24kW<\/td>\n<td>\u6ee1\u8db3\u91c7\u6696\uff0c\u70ed\u6c34\u6d41\u91cf\u7ea611L\/min<\/td>\n<\/tr>\n<tr>\n<td>100-150\u33a1<\/td>\n<td>24-28kW<\/td>\n<td>\u517c\u987e\u91c7\u6696\u4e0e\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td>150-200\u33a1<\/td>\n<td>28-35kW<\/td>\n<td>\u9700\u6821\u6838\u71c3\u6c14\u8868<\/td>\n<\/tr>\n<tr>\n<td>\u2265200\u33a1<\/td>\n<td>35kW+ \u6216 \u591a\u53f0\u5e76\u8054<\/td>\n<td>\u9700G4\u4ee5\u4e0a\u71c3\u6c14\u8868<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u529f\u7387\u6309\u9762\u79ef\u7c97\u5b9a\u53ea\u662f\u7b2c\u4e00\u6b65\uff0c\u8fd8\u8981\u7ed3\u5408\u672b\u7aef\u5f62\u5f0f\u4e0e\u70ed\u6c34\u9700\u6c42\u7ec6\u5316\u2014\u2014\u65b9\u6cd5\u89c1 <a href=\"?page_id=11074\">\u300a\u58c1\u6302\u7089\u600e\u4e48\u9009\u300b<\/a>\u3001<a href=\"?page_id=13489\">\u300a\u5355\u91c7\u6696\u7089\u600e\u4e48\u9009\u300b<\/a>\uff1b\u5404\u54c1\u724c\u7684\u673a\u578b\u8c31\u7cfb\u4e0e\u9002\u7528\u6237\u578b\u89c1 <a href=\"?page_id=835\">\u535a\u4e16<\/a> \u00b7 <a href=\"?page_id=1824\">\u83f2\u65af\u66fc<\/a> \u00b7 <a href=\"?page_id=1841\">\u66fc\u745e\u5fb7<\/a> \u00b7 <a href=\"?page_id=2489\">\u6797\u5185<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>2.1.2 \u58c1\u6302\u7089\u70ed\u6c34\u80fd\u529b\u901f\u7b97<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8ba1\u7b97\u516c\u5f0f<\/strong>\uff1a\u51fa\u6c34\u91cf(L\/min) = 0.86 \u00d7 \u529f\u7387(kW) \u00d7 1000 \u00d7 \u70ed\u6548\u7387 \u00f7 \u6e29\u5dee(\u2103) \u00f7 60<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9505\u7089\u529f\u7387<\/strong><\/td>\n<td><strong>\u70ed\u6548\u7387<\/strong><\/td>\n<td><strong>\u51fa\u6c34\u91cf\uff08\u51ac\u5b6340\u2103\u6e29\u5347\uff09<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>18kW<\/td>\n<td>80%<\/td>\n<td>\u7ea65.2L\/min<\/td>\n<td>\u5355\u70b9\u6d17\u624b\u76c6<\/td>\n<\/tr>\n<tr>\n<td>24kW<\/td>\n<td>80%<\/td>\n<td>\u7ea66.9L\/min<\/td>\n<td>\u52c9\u5f3a\u6ee1\u8db3\u666e\u901a\u82b1\u6d12<\/td>\n<\/tr>\n<tr>\n<td>28kW<\/td>\n<td>80%<\/td>\n<td>\u7ea68.0L\/min<\/td>\n<td>\u666e\u901a\u82b1\u6d12<\/td>\n<\/tr>\n<tr>\n<td>32kW<\/td>\n<td>80%<\/td>\n<td>\u7ea69.2L\/min<\/td>\n<td>\u5927\u82b1\u6d12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u5173\u952e\u8ba4\u77e5<\/strong>\uff1a\u666e\u901a\u82b1\u6d12\u97008L\/min\u4ee5\u4e0a\uff0c<strong>24kW\u4e24\u7528\u7089\u51ac\u5b63\u70ed\u6c34\u80fd\u529b\u52c9\u5f3a<\/strong>\u3002\u89e3\u51b3\u65b9\u6848\uff1a<strong>\u91c7\u6696\u4e0e\u751f\u6d3b\u70ed\u6c34\u5206\u79bb\u8bbe\u8ba1<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e24\u7528\u7089\u7684\u70ed\u6c34\u5230\u5e95\u591f\u4e0d\u591f\u3001\u6362\u6210\u72ec\u7acb\u70ed\u6c34\u5668\u4f1a\u4e0d\u4f1a\"\u964d\u7ea7\"\uff0c\u89c1 <a href=\"?page_id=13941\">\u300a\u71c3\u6c14\u58c1\u6302\u7089\u548c\u70ed\u6c34\u5668\u54ea\u4e2a\u70ed\u6c34\u6548\u679c\u597d\u300b<\/a>\uff1b\u6574\u5957\u70ed\u6c34\u7cfb\u7edf\u7684\u9009\u578b\u903b\u8f91\u89c1 <a href=\"?page_id=1879\">\u300a\u5bb6\u7528\u70ed\u6c34\u7cfb\u7edf\u600e\u4e48\u9009\u300b<\/a>\uff1b\u5bb6\u91cc\u4eba\u53e3\u591a\u3001\u8981\"\u5927\u6c34\u91cf+\u96f6\u6ce2\u52a8\"\uff0c\u89c1 <a href=\"?page_id=7648\">OTT \u6b27\u7279\u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>2.1.3 \u666e\u901a\u7089 vs \u51b7\u51dd\u7089\u9009\u62e9<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u666e\u901a\u7089<\/strong><\/td>\n<td><strong>\u51b7\u51dd\u7089<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6548\u7387\uff08\u771f\u5b9e\uff09<\/td>\n<td>80-84%<\/td>\n<td>93-97%<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/td>\n<td>8-10kW<\/td>\n<td>3-4kW<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u672b\u7aef<\/td>\n<td>\u6696\u6c14\u7247\uff08\u9ad8\u6e29\uff09<\/td>\n<td>\u5730\u6696\/\u4f4e\u6e29\u6696\u6c14\u7247\uff08\u4f4e\u6e29\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u521d\u6295\u8d44<\/td>\n<td>\u4f4e\uff087,000-9,000\u5143\uff09<\/td>\n<td>\u4e2d\u9ad8\uff0813,000-16,000\u5143\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5bff\u547d<\/td>\n<td>8-10\u5e74<\/td>\n<td>10-15\u5e74<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u4e24\u79cd\u7089\u5b50\u5404\u81ea\u7684\u6548\u7387\u3001\u6210\u672c\u4e0e\u9002\u7528\u8fb9\u754c\uff0c\u89c1 <a href=\"?page_id=12812\">\u300a\u51b7\u51dd\u7089\u548c\u666e\u901a\u7089\u600e\u4e48\u9009\u300b<\/a>\uff1b\u8001\u623f\u53ea\u52a0\u6696\u6c14\u7247\u3001\u4e0d\u52a8\u5730\u6696\u7684\u9009\u578b\u89c1 <a href=\"?page_id=12776\">\u300a\u8001\u623f\u660e\u88c5\u6696\u6c14\u600e\u4e48\u9009\u7089\u300b<\/a>\uff1b\u60f3\u628a\u70ed\u6e90\u6362\u6210\u7a7a\u6c14\u80fd\u6216\u6c34\u7cfb\u7edf\uff0c\u89c1 <a href=\"?page_id=3415\">\u300a\u5730\u6696\u70ed\u6e90\u6df1\u5ea6\u5bf9\u6bd4\u300b<\/a> \u4e0e <a href=\"?page_id=5601\">\u300a\u4e8c\u8054\u4f9b vs \u51b7\u51dd\u7089+\u8282\u80fd\u5730\u6696\u300b<\/a>\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.2 \u7ba1\u8def\u7cfb\u7edf\u4e0e\u6c34\u529b\u5e73\u8861<\/h3>\n<p class=\"wp-block-paragraph\"><strong>2.2.1 \u4e09\u79cd\u57fa\u7840\u5f62\u6001<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u5b9a\u4e49<\/strong><\/td>\n<td><strong>\u7279\u70b9<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5f02\u7a0b\u7cfb\u7edf<\/strong><\/td>\n<td>\u4f9b\u6c34\u7ba1\u548c\u56de\u6c34\u7ba1\uff0c\u5404\u652f\u8def\u7ba1\u9053\u957f\u5ea6\u4e0d\u540c\uff0c\u201c\u5148\u8fdb\u5148\u56de\u201d<\/td>\n<td>\u65bd\u5de5\u7b80\u5355\uff0c\u6210\u672c\u4f4e\uff1b\u6c34\u529b\u5931\u8861\u4e25\u91cd\uff0c\u8fd1\u7aef\u70ed\u8fdc\u7aef\u51b7<\/td>\n<td>\u5c0f\u6237\u578b\u660e\u88c5\uff0c\u4e0d\u63a8\u8350<\/td>\n<\/tr>\n<tr>\n<td><strong>\u540c\u7a0b\u7cfb\u7edf<\/strong><\/td>\n<td>\u901a\u8fc7\u5ef6\u957f\u56de\u6c34\u7ba1\u8def\uff0c\u4f7f\u5404\u652f\u8def\u4f9b\u56de\u6c34\u603b\u957f\u57fa\u672c\u76f8\u7b49<\/td>\n<td>\u6c34\u529b\u5e73\u8861\u597d\uff0c\u5404\u672b\u7aef\u6e29\u5ea6\u5747\u5300\uff1b\u7ba1\u8def\u8f83\u957f\uff0c\u6210\u672c\u7565\u9ad8<\/td>\n<td>\u5730\u6696\u3001\u6697\u88c5\u6696\u6c14\u7247<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ae0\u9c7c\u5f0f\uff08\u5206\u96c6\u6c34\u5668\uff09<\/strong><\/td>\n<td>\u4ece\u5206\u96c6\u6c34\u5668\u72ec\u7acb\u5f15\u51fa\u5404\u652f\u8def\uff0c\u7ba1\u957f\u76f8\u8fd1<\/td>\n<td>\u6c34\u529b\u5e73\u8861\u6700\u4f18\uff0c\u72ec\u7acb\u63a7\u5236\uff1b\u63a5\u5934\u591a\uff0c\u9700\u6697\u57cb<\/td>\n<td>\u6697\u88c5\u5730\u6696\/\u6696\u6c14\u7247\u9996\u9009<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.2.2 \u540c\u7a0b\u7cfb\u7edf\u7684\u4e24\u79cd\u5b9e\u73b0\u5f62\u5f0f<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5f62\u5f0f\u4e00\uff1a\u96c6\u4e2d\u5f0f\u540c\u7a0b\uff08\u7ae0\u9c7c\u5f0f\/\u5206\u96c6\u6c34\u5668\uff09<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u539f\u7406<\/strong>\uff1a\u6240\u6709\u652f\u8def\u7684\u4e3b\u7ba1\u96c6\u4e2d\u5230\u5206\u96c6\u6c34\u5668\uff0c\u4ece\u5206\u96c6\u6c34\u5668\u72ec\u7acb\u5f15\u51fa\u4f9b\u56de\u6c34\u7ba1\u5230\u6bcf\u4e2a\u672b\u7aef\uff0c\u518d\u56de\u5230\u5206\u96c6\u6c34\u5668<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\u5404\u652f\u8def\u7ba1\u957f\u4e00\u81f4\uff0c\u6c34\u529b\u5e73\u8861\u6700\u597d\uff1b\u6bcf\u4e2a\u672b\u7aef\u53ef\u72ec\u7acb\u63a7\u5236\u548c\u68c0\u4fee<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5f62\u5f0f\u4e8c\uff1a\u5206\u5e03\u5f0f\u540c\u7a0b\uff08\u4e09\u7ba1\u5236\/\u4e24\u7ba1\u5236\u540c\u7a0b\uff09<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u539f\u7406<\/strong>\uff1a\u4f9b\u6c34\u7ba1\u4f9d\u6b21\u7ecf\u8fc7\u5404\u672b\u7aef\uff0c\u56de\u6c34\u7ba1\u4ece\u6700\u8fdc\u7aef\u5f00\u59cb\u4f9d\u6b21\u6536\u96c6\uff0c\u4f7f\u6bcf\u4e2a\u672b\u7aef\u7684\u4f9b\u56de\u6c34\u603b\u8def\u7a0b\u76f8\u7b49<\/li>\n<li><strong>\u4e09\u7ba1\u5236\u540c\u7a0b<\/strong>\uff1a\u4e00\u4f9b\u4e24\u56de\u6216\u4e24\u4f9b\u4e00\u56de\uff0c\u56de\u6c34\u7ba1\u591a\u4e00\u4e2a\u6298\u5f2f<\/li>\n<li><strong>\u4e24\u7ba1\u5236\u540c\u7a0b<\/strong>\uff1a\u4e00\u4f9b\u4e00\u56de\uff0c\u901a\u8fc7\u7ba1\u9053\u8d70\u5411\u8bbe\u8ba1\u5b9e\u73b0\u5404\u652f\u8def\u7b49\u957f<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>2.2.3 \u5355\u7ba1\u7cfb\u7edf\u8be6\u89e3<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5355\u7ba1\u4e32\u8054\u7cfb\u7edf\uff08\u6c34\u5e73\u5355\u7ba1\u8de8\u8d8a\u5f0f\uff09<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u539f\u7406<\/strong>\uff1a\u4f9b\u56de\u6c34\u4e3b\u7ba1\u4e3a\u4e00\u6839\u7ba1\u9053\uff0c\u6563\u70ed\u5668\u4e32\u8054\u5728\u8fd9\u6839\u4e3b\u7ba1\u4e0a\uff0c\u6bcf\u7ec4\u6563\u70ed\u5668\u5904\u8bbe\u8de8\u8d8a\u7ba1\u548cH\u9600<\/li>\n<li><strong>H\u9600\u7684\u4f5c\u7528<\/strong>\uff1a\u5177\u5907\u65c1\u901a\u529f\u80fd\uff0c\u53ef\u8bbe\u5b9a\u8fdb\u5165\u6563\u70ed\u5668\u7684\u6c34\u91cf\u767e\u5206\u6bd4\uff08\u901a\u5e3830%-50%\uff09\uff1b\u6709\u5173\u65ad\u529f\u80fd\uff0c\u65b9\u4fbf\u5355\u7ec4\u7ef4\u4fee<\/li>\n<li><strong>\u9002\u7528\u573a\u666f<\/strong>\uff1a\u5206\u6237\u72ec\u7acb\u5faa\u73af\u7cfb\u7edf\uff0c70-140\u33a1\u4e2d\u7b49\u6237\u578b<\/li>\n<li><strong>\u8282\u80fd\u6548\u679c<\/strong>\uff1a\u6bd4\u53cc\u7ba1\u5f02\u7a0b\u8282\u80fd10-15%<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>2.2.4 \u6df7\u7ba1\u540c\u7a0b\u2014\u2014\u6c34\u529b\u5e73\u8861\u7684\u7ec8\u6781\u65b9\u6848<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u53cc\u7ba1\u5f02\u7a0b<\/strong><\/td>\n<td><strong>\u5355\u7ba1\u5236<\/strong><\/td>\n<td><strong>\u6df7\u7ba1\u540c\u7a0b<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u529b\u5e73\u8861<\/td>\n<td>\u5dee<\/td>\n<td>\u4e2d\u7b49<\/td>\n<td><strong>\u6700\u4f18<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u8def\u6210\u672c<\/td>\n<td>\u4f4e<\/td>\n<td>\u8f83\u4f4e<\/td>\n<td>\u4e2d\u7b49<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u9762\u79ef<\/td>\n<td>\u226470\u33a1<\/td>\n<td>70-140\u33a1<\/td>\n<td><strong>\u4efb\u610f\u9762\u79ef<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u9002\u914d\u51b7\u51dd\u7089<\/td>\n<td>\u4e0d\u63a8\u8350<\/td>\n<td>\u53ef\u9002\u914d<\/td>\n<td><strong>\u6700\u4f73\u9002\u914d<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8282\u80fd\u6548\u679c<\/td>\n<td>\u57fa\u51c6<\/td>\n<td>+10-15%<\/td>\n<td><strong>+20%\u4ee5\u4e0a<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.2.5 \u7ba1\u5f84\u9009\u62e9\u901f\u67e5\u8868<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4e3b\u7ba1<\/strong><\/td>\n<td><strong>\u652f\u7ba1<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>De25<\/td>\n<td>De16<\/td>\n<td>100\u33a1\u4ee5\u5185\u5c0f\u6237\u578b<\/td>\n<\/tr>\n<tr>\n<td>De32<\/td>\n<td>De20<\/td>\n<td>100-200\u33a1\u5927\u5e73\u5c42<\/td>\n<\/tr>\n<tr>\n<td>De40<\/td>\n<td>De25<\/td>\n<td>200\u33a1\u4ee5\u4e0a\u522b\u5885<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">2.3 \u63a7\u5236\u8054\u52a8\u7b56\u7565<\/h3>\n<p class=\"wp-block-paragraph\"><strong>2.3.1 \u6e29\u63a7\u5668\u8054\u52a8<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u5ba4\u5185\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u8054\u52a8\uff0c\u5ba4\u6e29\u8fbe\u6807\u2192\u9505\u7089\u505c\u673a<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>2.3.2 \u5206\u5ba4\u63a7\u5236<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u4ec5\u5f00\u542f\u4f7f\u7528\u623f\u95f4\u7684\u672b\u7aef\uff0c\u907f\u514d\u5168\u5c4b\u4f9b\u6696\u6d6a\u8d39<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>2.3.3 \u591a\u673a\u5e76\u8054\u8054\u52a8\u8bbe\u8ba1<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u9002\u7528\u573a\u666f\uff1a\u522b\u5885\/\u5927\u5e73\u5c42\uff0c\u91c7\u6696\u9762\u79ef\u2265300\u33a1<\/li>\n<li>\u6838\u5fc3\u4f18\u52bf\uff1a\u5c11\u91cf\u9700\u6c42\u65f6\u53ea\u542f\u52a8\u4e00\u53f0\uff0c\u6ee1\u8d1f\u8377\u65f6\u591a\u53f0\u540c\u6b65\uff1b\u5355\u673a\u6545\u969c\u4e0d\u5f71\u54cd\u6574\u4f53\u91c7\u6696<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>2.3.4 \u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u907f\u514d\u9505\u7089\u9891\u7e41\u5207\u6362\u6a21\u5f0f<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">2.4 \u6c34\u7cfb\u7edf\u91c7\u6696\u8bbe\u8ba1\u56db\u8981\u7d20\u4e0e\u7ba1\u8def\u5339\u914d<\/h3>\n<p class=\"wp-block-paragraph\"><strong>2.4.1 \u7ba1\u5f84-\u6d41\u91cf-\u70ed\u503c\u901f\u67e5\u8868\uff0810\u2103\u6e29\u5dee\uff09<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ba1\u5f84<\/strong><\/td>\n<td><strong>\u5185\u5f84(\u7ea6)<\/strong><\/td>\n<td><strong>\u53c2\u8003\u6d41\u91cf<\/strong><\/td>\n<td><strong>\u53ef\u643a\u5e26\u70ed\u503c<\/strong><\/td>\n<td><strong>\u5bf9\u5e94\u6d41\u901f<\/strong><\/td>\n<td><strong>\u7ea6\u675f\u6761\u4ef6<\/strong><\/td>\n<\/tr>\n<tr>\n<td>De16<\/td>\n<td>12mm<\/td>\n<td>~100 L\/h<\/td>\n<td>~1.2 kW<\/td>\n<td>~0.25 m\/s<\/td>\n<td>\u76d8\u7ba1\u2264120m\uff0c\u6d41\u901f\u22640.5m\/s<\/td>\n<\/tr>\n<tr>\n<td>De20<\/td>\n<td>16mm<\/td>\n<td>~200 L\/h<\/td>\n<td>~2.3 kW<\/td>\n<td>~0.28 m\/s<\/td>\n<td>\u76d8\u7ba1\u2264120m\uff0c\u6d41\u901f\u22640.5m\/s<\/td>\n<\/tr>\n<tr>\n<td>De25<\/td>\n<td>20mm<\/td>\n<td>~500 L\/h<\/td>\n<td>~5.8 kW<\/td>\n<td>~0.44 m\/s<\/td>\n<td>\u652f\u7ba1\u226450m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td><strong>De32<\/strong><\/td>\n<td><strong>26mm<\/strong><\/td>\n<td><strong>~1,000 L\/h<\/strong><\/td>\n<td><strong>~11.6 kW<\/strong><\/td>\n<td><strong>~0.52 m\/s<\/strong><\/td>\n<td>\u4e3b\u7ba1\u226480m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td><strong>De40<\/strong><\/td>\n<td><strong>32mm<\/strong><\/td>\n<td><strong>~2,000 L\/h<\/strong><\/td>\n<td><strong>~23.2 kW<\/strong><\/td>\n<td><strong>~0.69 m\/s<\/strong><\/td>\n<td>\u4e3b\u7ba1\u2264100m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td>De50<\/td>\n<td>40mm<\/td>\n<td>~5,000 L\/h<\/td>\n<td>~58 kW<\/td>\n<td>~1.10 m\/s<\/td>\n<td>\u4e3b\u7ba1\u2264120m\uff0c\u6d41\u901f\u22641.5m\/s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.4.2 \u58c1\u6302\u7089\u6700\u5c0f\u8d1f\u8377\u4e0e\u6ee1\u8d1f\u8377\u7684\u7ba1\u5f84\u5339\u914d<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u4ee5100\u33a1\u5730\u6696\u4e3a\u4f8b\uff08\u8bbe\u8ba1\u8d1f\u83775kW\uff0c\u58c1\u6302\u708924kW\uff09\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8fd0\u884c\u72b6\u6001<\/strong><\/td>\n<td><strong>\u6240\u9700\u70ed\u8d1f\u8377<\/strong><\/td>\n<td><strong>\u6240\u9700\u6d41\u91cf<\/strong><\/td>\n<td><strong>\u5339\u914d\u7ba1\u5f84<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6700\u5c0f\u8d1f\u8377\u8fd0\u884c<\/strong><\/td>\n<td>~10kW<\/td>\n<td>~1,000 L\/h<\/td>\n<td><strong>De32<\/strong><\/td>\n<td>32\u7ba1\u53ef\u6ee1\u8db3\u6700\u5c0f\u8d1f\u8377\u8f93\u70ed<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6ee1\u8d1f\u8377\u8fd0\u884c<\/strong><\/td>\n<td>24kW<\/td>\n<td>~2,400 L\/h<\/td>\n<td><strong>De40<\/strong><\/td>\n<td>32\u7ba1\u6d41\u91cf\u4e0d\u8db3\uff0c\u970040\u7ba1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5e02\u573a\u901a\u914d<\/strong><\/td>\n<td>24kW<\/td>\n<td>~900 L\/h\uff08\u5b9e\u9645\uff09<\/td>\n<td>De25<\/td>\n<td><strong>\u4e25\u91cd\u4e0d\u8db3<\/strong>\uff0c\u70ed\u91cf\u8fd0\u4e0d\u8d70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u58c1\u6302\u7089\u7cfb\u7edf\u4e3b\u7ba1<strong>\u81f3\u5c11\u9009De32<\/strong>\uff0c\u63a8\u8350<strong>De40<\/strong>\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e09\u90e8\u5206\uff1a\u70ed\u6c34\u7cfb\u7edf\u4e13\u9879\u8bbe\u8ba1<\/h2>\n<h3 class=\"wp-block-heading\">3.1 \u5bb6\u5ead\u70ed\u6c34\u7cfb\u7edf\u8bbe\u8ba1\u7406\u5ff5<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7406\u5ff5<\/strong>\uff1a\u4ece\u201c\u672b\u7aef\u9700\u6c42\u201d\u5230\u201c\u70ed\u6e90\u5339\u914d\u201d\u7684\u7cfb\u7edf\u5316\u8bbe\u8ba1<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4f20\u7edf\u601d\u7ef4<\/strong><\/td>\n<td><strong>\u7cfb\u7edf\u5316\u601d\u7ef4<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u53ea\u770b\u70ed\u6c34\u5668\u5347\u6570<\/td>\n<td>\u4ece\u672b\u7aef\u9700\u6c42\u5012\u63a8<\/td>\n<\/tr>\n<tr>\n<td>\u4e70\u5927\u5347\u6570\u8bbe\u5907<\/td>\n<td>\u786e\u5b9a\u5cf0\u503c\u6d41\u91cf<\/td>\n<\/tr>\n<tr>\n<td>\u5ffd\u7565\u7ba1\u9053\u3001\u6c34\u529b\u3001\u71c3\u6c14\u9650\u5236<\/td>\n<td>\u8bbe\u8ba1\u6c34\u529b\u5e73\u8861\u2192\u8ba1\u7b97\u70ed\u8d1f\u8377\u2192\u9009\u578b\u70ed\u6e90\u2192\u6821\u6838\u71c3\u6c14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">3.2 \u4e3b\u7ba1\u5faa\u73af vs \u96f6\u51b7\u6c34\uff08\u652f\u7ba1\u5faa\u73af\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u4e3b\u7ba1\u5faa\u73af\uff08\u63a8\u8350\uff09<\/strong><\/td>\n<td><strong>\u96f6\u51b7\u6c34\/\u652f\u7ba1\u5faa\u73af\uff08\u4e0d\u63a8\u8350\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u4e49<\/td>\n<td>\u5faa\u73af\u53ea\u505a\u5230\u5206\u96c6\u6c34\u5668\uff0c\u652f\u7ba1\u4e0d\u53c2\u4e0e\u5faa\u73af<\/td>\n<td>\u5faa\u73af\u505a\u5230\u6bcf\u4e2a\u7528\u6c34\u70b9\u672b\u7aef<\/td>\n<\/tr>\n<tr>\n<td>\u65bd\u5de5\u6210\u672c<\/td>\n<td>\u8f83\u4f4e<\/td>\n<td>\u5f88\u9ad8\uff08\u9700\u9884\u57cb\u5927\u91cf\u56de\u6c34\u7ba1\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4f7f\u7528\u4f53\u9a8c<\/td>\n<td>2-3\u79d2\u51fa\u70ed\u6c34<\/td>\n<td>\u79d2\u51fa\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6e29\u7a33\u5b9a\u6027<\/td>\n<td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5168\u5c4b\u5747\u8861<\/td>\n<td>\u2b50\u2b50 \u8fd1\u7aef\u70eb\u3001\u8fdc\u7aef\u51c9<\/td>\n<\/tr>\n<tr>\n<td>\u80fd\u8017<\/td>\n<td><strong>\u4f4e<\/strong>\uff08\u5faa\u73af\u6bb5\u77ed\uff09<\/td>\n<td><strong>\u9ad8<\/strong>\uff08\u70ed\u91cf\u6563\u5931\u5230\u5899\u4f53\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5065\u5eb7\u5b89\u5168<\/td>\n<td>\u2705 \u70ed\u6c34\u4e0d\u5165\u51b7\u6c34\u7ba1<\/td>\n<td>\u274c \u53ef\u80fd\u5012\u704c\u51c0\u6c34\u5668<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">3.3 \u6052\u6e29\u70ed\u6c34\u5668\u4e94\u8981\u7d20\u6280\u672f\u89e3\u6790<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8981\u7d20<\/strong><\/td>\n<td><strong>\u529f\u80fd<\/strong><\/td>\n<td><strong>\u4f5c\u7528<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14\u6bd4\u4f8b\u9600<\/strong><\/td>\n<td>\u6839\u636e\u6c34\u6d41\u91cf\u7cbe\u786e\u8c03\u8282\u71c3\u6c14\u91cf<\/td>\n<td>\u5927\u706b\u5927\u71c3\u6c14\uff0c\u5c0f\u706b\u5c0f\u71c3\u6c14<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u91cf\u4f3a\u670d\u5668<\/strong><\/td>\n<td>\u6839\u636e\u8fdb\u6c34\u6e29\u5ea6\u548c\u8bbe\u5b9a\u6e29\u5ea6\u81ea\u52a8\u8c03\u8282\u6c34\u6d41\u91cf<\/td>\n<td>\u6052\u6e29\u51fa\u6c34\u7684\u57fa\u7840<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5206\u6bb5\u71c3\u70e7<\/strong><\/td>\n<td>\u53ea\u5728\u751f\u6d3b\u70ed\u6c34\u6a21\u5f0f\u5207\u5206\u6bb5\uff1a\u628a\u4e00\u6839\u71c3\u6c14\u7ba1\u6539\u6210\u4e24\u6839\uff0c\u590f\u5929\u5c0f\u6c34\u91cf\u65f6\u53ea\u70b9\u4e00\u6392\u706b<\/td>\n<td>\u89e3\u51b3\u590f\u5b63\u6c34\u6e29\u8fc7\u70eb\uff1b\u91c7\u6696\u6a21\u5f0f\u4e0d\u5207\u5206\u6bb5<\/td>\n<\/tr>\n<tr>\n<td><strong>\u76d8\u9f99\u65cb\u98ce\u7ba1<\/strong><\/td>\n<td>\u4f18\u5316\u6362\u70ed\u8def\u5f84<\/td>\n<td>\u63d0\u5347\u6362\u70ed\u6548\u7387<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u91cf\u4f20\u611f\u5668<\/strong><\/td>\n<td>\u5b9e\u65f6\u68c0\u6d4b\u6d41\u91cf<\/td>\n<td>\u5feb\u901f\u54cd\u5e94\uff0c\u7cbe\u51c6\u63a7\u6e29<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">3.4 \u4e24\u7528\u7089+\u96f6\u51b7\u6c34\u7684\u4e09\u5927\u95ee\u9898<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u5148\u8bf4\u6839\u5b50\uff1a\u4e00\u53f0\u4e24\u7528\u7089\u53ea\u6709\u4e00\u4e2a\u7089\u819b\u3002<\/strong>\u91c7\u6696\u8981\u7528\u5b83\uff0c\u70ed\u6c34\u4e5f\u8981\u7528\u5b83\uff0c\u5382\u5bb6\u7684\u505a\u6cd5\u662f\"\u70ed\u6c34\u4f18\u5148\"\u2014\u2014\u53ea\u8981\u6709\u4eba\u7528\u70ed\u6c34\uff0c\u4e09\u901a\u9600\u5207\u8fc7\u53bb\uff0c\u91c7\u6696\u7acb\u523b\u505c\u3002\u6240\u4ee5\u51ac\u5929\u6d17\u6fa1\u7684\u65f6\u5019\uff0c\u5730\u6696\u662f\u5728\u6389\u6e29\u7684\u3002\u6d17\u4e8c\u5341\u5206\u949f\uff0c\u5730\u6696\u6e29\u5ea6\u6389\u597d\u51e0\u5ea6\uff0c\u51fa\u6765\u4ee5\u540e\u8981\u8fc7\u4e00\u9635\u624d\u7f13\u56de\u6765\u3002\u8fd9\u4e0d\u662f\u6545\u969c\uff0c\u662f\u4e24\u7528\u7089\u7684\u7ed3\u6784\u51b3\u5b9a\u7684\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u7b2c\u4e8c\u5c42\u6839\u5b50\u5728\u529f\u7387\u3002\u4e24\u7528\u7089\u7684\u529f\u7387\u672c\u6765\u5c31\u662f\u6309\u70ed\u6c34\u6491\u51fa\u6765\u7684\uff08\u8fd9\u4e2a\u8d26\u600e\u4e48\u7b97\u7684\uff0c\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=16477\">\u58c1\u6302\u7089\u6280\u672f\u8bfb\u672c<\/a>\u7b2c\u516d\u8282\uff09\uff0c\u53ef\u6491\u51fa\u6765\u4e5f\u4e0d\u5bbd\u88d5\uff1a\u51ac\u5929 40\u2103 \u6e29\u5347\u53ea\u6709 6.9 \u5347\u6bcf\u5206\u949f\uff0c\u4e00\u4e2a\u82b1\u6d12\u5c31\u662f 8 \u5347\u3002\u4e00\u4e2a\u536b\u751f\u95f4\u52c9\u5f3a\uff0c\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u5f00\uff0c\u4e24\u8fb9\u90fd\u53d8\u7ec6\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u7b2c\u4e09\u5c42\u6839\u5b50\u5728\u8c03\u8282\u3002\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa 8\u201310kW\uff0c\u964d\u4e0d\u4e0b\u6765\u3002\u4f60\u88c5\u4e86\u6052\u6e29\u82b1\u6d12\uff0c\u5b83\u4f1a\u81ea\u52a8\u628a\u51b7\u6c34\u8fdb\u91cf\u538b\u5c0f\u6765\u7a33\u4f4f\u6c34\u6e29\uff0c\u8fdb\u9505\u7089\u7684\u6c34\u5c11\u4e86\uff0c\u9505\u7089\u8fd8\u5728\u6309\u6700\u5c0f\u529f\u7387\u70e7\uff0c\u6c34\u6e29\u7acb\u523b\u5f80\u4e0a\u51b2\uff0c\u51b2\u5230\u4e0a\u9650\u5c31\u62a5\u8d85\u6e29\u3002\u6240\u4ee5\u5f88\u591a\u5bb6\u5ead\u7684 E1\u3001E4 \u4e0d\u662f\u673a\u5668\u574f\u4e86\uff0c\u662f\u6052\u6e29\u82b1\u6d12\u548c\u5b9a\u9891\u7089\u914d\u5728\u4e00\u8d77\uff0c\u4e24\u4e2a\u90fd\u5728\u6309\u81ea\u5df1\u7684\u903b\u8f91\u5e72\u6d3b\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e09\u4ef6\u4e8b\u53e0\u5728\u4e00\u8d77\uff0c\u7ed3\u8bba\u5c31\u5f88\u6e05\u695a\uff1a<strong>\u4e24\u4e2a\u4ee5\u4e0a\u536b\u751f\u95f4\u3001\u5bb6\u91cc\u6709\u6d74\u7f38\u3001\u6216\u8005\u60f3\u505a\u96f6\u51b7\u6c34\uff0c\u91c7\u6696\u548c\u70ed\u6c34\u5fc5\u987b\u5206\u5f00\u3002<\/strong>\u9505\u7089\u53ea\u7ba1\u91c7\u6696\uff0c\u53ef\u4ee5\u6309\u91c7\u6696\u8d1f\u8377\u9009\u5c0f\u4e00\u6863\uff0c\u65e2\u7701\u6c14\u53c8\u7a33\u5b9a\uff1b\u70ed\u6c34\u4ea4\u7ed9\u4e13\u95e8\u7684\u8bbe\u5907\uff0c\u8981\u591a\u5927\u914d\u591a\u5927\u3002\u4e0b\u9762\u8fd9\u4e09\u6761\uff0c\u90fd\u662f\u5728\u8fd9\u4e2a\u524d\u63d0\u4e0a\u518d\u5f80\u4e0b\u8d70\u7684\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u95ee\u9898\u4e00\uff1a\u529f\u7387\u4e0d\u8db3<\/strong>\uff1a24kW\u4e24\u7528\u7089\u51ac\u5b63\u51fa\u6c34\u91cf\u4ec56.9L\/min\uff0c\u52a0\u5faa\u73af\u6cf5\u540e\u70ed\u6c34\u88ab\u5899\u4f53\u6563\u70ed\uff0c\u5b9e\u9645\u51fa\u6c34\u6e29\u5ea6\u66f4\u4f4e<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u95ee\u9898\u4e8c\uff1a\u8d85\u6e29\u6545\u969c<\/strong>\uff1a\u4f7f\u7528\u6052\u6e29\u82b1\u6d12\/\u6052\u6e29\u9600\u540e\uff0c\u8fdb\u9505\u7089\u7684\u51b7\u6c34\u91cf\u51cf\u5c11\uff0c\u9505\u7089\u6700\u5c0f\u529f\u73878-10kW\uff0c\u6c34\u6e29\u5feb\u901f\u4e0a\u5347\u2192\u8d85\u6e29\u62a5\u8b66\uff08E1\/E4\uff09<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u95ee\u9898\u4e09\uff1a\u80fd\u8017\u6781\u9ad8<\/strong>\uff1a\u96f6\u51b7\u6c34\u970024\u5c0f\u65f6\u5faa\u73af\uff0c\u5899\u4f53\u6563\u70ed+\u9505\u7089\u9891\u7e41\u542f\u505c<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a<strong>\u575a\u51b3\u4e0d\u63a8\u8350\u4e24\u7528\u7089\u505a\u96f6\u51b7\u6c34<\/strong>\u3002\u5982\u5fc5\u987b\u505a\u96f6\u51b7\u6c34\uff0c\u52a1\u5fc5<strong>\u70ed\u6c34\u7cfb\u7edf\u72ec\u7acb<\/strong>\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.5 \u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668\u7684\u524a\u5cf0\u586b\u8c37\u539f\u7406<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8bbe\u5907\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u5de5\u4f5c\u539f\u7406<\/strong><\/td>\n<td><strong>\u9002\u7528\u5cf0\u503c\u9700\u6c42<\/strong><\/td>\n<\/tr>\n<tr>\n<td>16L\u71c3\u6c14\u70ed\u6c34\u5668<\/td>\n<td>\u5373\u70ed\u5f0f<\/td>\n<td>\u226415L\/min<\/td>\n<\/tr>\n<tr>\n<td>24L\u71c3\u6c14\u70ed\u6c34\u5668<\/td>\n<td>\u5373\u70ed\u5f0f<\/td>\n<td>15-20L\/min<\/td>\n<\/tr>\n<tr>\n<td>200L\u5bb9\u79ef\u5f0f<\/td>\n<td>\u50a8\u70ed\u5f0f\uff0c70\u2103\u50a8\u6c34<\/td>\n<td>25-35L\/min<\/td>\n<\/tr>\n<tr>\n<td>300L\u5bb9\u79ef\u5f0f<\/td>\n<td>\u50a8\u70ed\u5f0f<\/td>\n<td>\u226535L\/min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6052\u6e29\u9600\u6269\u5bb9\u91cf\u8ba1\u7b97<\/strong>\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">V\u6df7\u5408 = V\u50a8\u70ed \u00d7 (T\u50a8\u70ed - T\u51b7\u6c34) \u00f7 (T\u76ee\u6807 - T\u51b7\u6c34)<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\">\u793a\u4f8b\uff1a200L\u50a8\u70ed\uff0c70\u2103\u50a8\u70ed\uff0c10\u2103\u51b7\u6c34\uff0c43\u2103\u76ee\u6807 \u2192 200\u00d760\u00f733\u2248<strong>363L<\/strong>\u53ef\u7528\u70ed\u6c34\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.6 \u70ed\u6c34\u7cfb\u7edf\u65b9\u6848\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6237\u578b<\/strong><\/td>\n<td><strong>\u63a8\u8350\u65b9\u6848<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u914d\u7f6e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e2d\u5c0f\u6237\u578b\u6e05\u6c34\u88c5\u4fee<\/td>\n<td>\u745e\u7f8e\u666e\u901a\u7089\/\u51b7\u51dd\u7089 + \u745e\u5c0f\u767d + \u4e3b\u7ba1\u4fdd\u6e29\u5faa\u73af<\/td>\n<td>\u5168\u5c4b\u963b\u6c27\u7ba1+\u65e0\u63a5\u5934\u652f\u7ba1+\u6052\u6e29\u9600<\/td>\n<\/tr>\n<tr>\n<td>\u5927\u5e73\u5c42\/\u522b\u5885<\/td>\n<td>\u745e\u7f8e\u51b7\u51dd\u7089 + \u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668 + \u6bcf\u5c42\u5faa\u73af\u6cf5<\/td>\n<td>\u5168\u5c4b\u963b\u6c27\u7ba1+\u4e3b\u7ba1\u4fdd\u6e29\u5faa\u73af<\/td>\n<\/tr>\n<tr>\n<td>\u4e2d\u5c0f\u6237\u578b\u660e\u88c5<\/td>\n<td>\u745e\u7f8e\u666e\u901a\u7089 + \u745e\u5c0f\u767d + \u94dd\u5851\u91c7\u6696\u7ba1<\/td>\n<td>\u6696\u6c14\u7247+\u4e54\u6cbbPERT16\u76f4\u7ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u56db\u90e8\u5206\uff1a\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u6307\u5357<\/h2>\n<h3 class=\"wp-block-heading\">4.1 \u963b\u6c27\u7ba1\u4e0e\u7cfb\u7edf\u8150\u8680<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u8150\u8680\u7684\u4e09\u5927\u673a\u7406<\/strong>\uff1a<\/p>\n<ol class=\"wp-block-list\">\n<li><strong>\u7535\u5316\u5b66\u8150\u8680<\/strong>\uff1a\u94dc\uff08\u9505\u7089\u6362\u70ed\u5668\uff09+ \u94a2\uff08\u6696\u6c14\u7247\uff09+ \u6c34 = \u539f\u7535\u6c60\u6548\u5e94<\/li>\n<li><strong>\u6c27\u6c14\u6e17\u900f\u8150\u8680<\/strong>\uff1a\u6c27\u6c14\u901a\u8fc7\u7ba1\u58c1\u6e17\u5165\uff0c\u5f62\u6210\u6c27\u6d53\u5dee\u7535\u6c60<\/li>\n<li><strong>\u9ad8\u6e29\u52a0\u901f\u8150\u8680<\/strong>\uff1a\u6c34\u6e29\u6bcf\u5347\u9ad810\u2103\uff0c\u8150\u8680\u901f\u7387\u589e\u52a01-2\u500d<\/li>\n<\/ol>\n<p class=\"wp-block-paragraph\"><strong>\u8150\u8680\u7684\u8868\u73b0\u4e0e\u5224\u65ad<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8868\u73b0<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u9ed1\u6c34<\/td>\n<td>\u6253\u5f00\u6392\u6c34\u9600\u6d41\u51fa\u9ed1\u8272\u6d51\u6d4a\u6c34\uff0c\u8bf4\u660e\u7cfb\u7edf\u5df2\u53d1\u751f\u4e25\u91cd\u8150\u8680<\/td>\n<\/tr>\n<tr>\n<td>\u5f02\u5473<\/td>\n<td>\u786b\u5316\u6c22\u7b49\u6c14\u4f53\u4ea7\u751f\uff0c\u7c7b\u4f3c\u81ed\u9e21\u86cb\u5473<\/td>\n<\/tr>\n<tr>\n<td>\u5c40\u90e8\u6f0f\u6c34<\/td>\n<td>\u9600\u95e8\u3001\u710a\u70b9\u3001\u6696\u6c14\u7247\u5e95\u90e8\u6700\u5148\u88ab\u8150\u8680\u7a7f\u5b54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u963b\u6c27\u7ba1\u9009\u578b<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ba1\u6750<\/strong><\/td>\n<td><strong>\u963b\u6c27\u65b9\u5f0f<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u963b\u6c27PE-RT<\/td>\n<td>EVOH\u963b\u6c27\u5c42\uff08\u4e94\u5c42\uff09<\/td>\n<td>\u5730\u6696\u76d8\u7ba1\u9996\u9009<\/td>\n<\/tr>\n<tr>\n<td>\u94dd\u5851\u590d\u5408\u7ba1<\/td>\n<td>\u94dd\u5c42\u5929\u7136\u7edd\u6c27<\/td>\n<td>\u652f\u7ba1\/\u4e3b\u7ba1\uff0c\u5168\u5c4b\u7edd\u6c27\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>PPR\uff08S3.2\uff09<\/td>\n<td>\u9700\u94dd\u5851\u590d\u5408<\/td>\n<td>\u4e3b\u7ba1\u9053\uff0c\u6ce8\u610f\u58c1\u539a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u5173\u952e\u539f\u5219<\/strong>\uff1a<strong>\u4e00\u534a\u963b\u6c27\u4e00\u534a\u4e0d\u963b\u6c27 = \u767d\u505a<\/strong>\u3002\u7cfb\u7edf\u5185\u963b\u6c27\u5fc5\u987b\u7edf\u4e00\u3002<\/p>\n<h3 class=\"wp-block-heading\">4.2 \u6362\u70ed\u5668\u6750\u8d28\u5bf9\u6bd4\uff1a\u4e0d\u9508\u94a2 vs \u94dc<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u94dc\u6362\u70ed\u5668<\/strong><\/td>\n<td><strong>\u4e0d\u9508\u94a2\u6362\u70ed\u5668<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5bfc\u70ed\u6548\u7387<\/td>\n<td><strong>\u9ad8<\/strong><\/td>\n<td>\u8f83\u4f4e\uff08\u9700\u52a0\u5bc6\u7fc5\u7247\u8865\u507f\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6297\u8150\u8680\u6027<\/td>\n<td>\u5dee\uff08\u9178\u6027\u51b7\u51dd\u6c34\u6613\u8150\u8680\uff09<\/td>\n<td><strong>\u4f18<\/strong>\uff08\u8010\u9178\u78b1\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5bff\u547d<\/td>\n<td>8-10\u5e74<\/td>\n<td>15\u5e74\u4ee5\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u7089\u578b<\/td>\n<td>\u666e\u901a\u7089\uff08\u9ad8\u6e29\u8fd0\u884c\uff09<\/td>\n<td><strong>\u51b7\u51dd\u7089<\/strong>\uff08\u5fc5\u9009\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u9009\u578b\u539f\u5219<\/strong>\uff1a\u51b7\u51dd\u7089\u5fc5\u987b\u9009\u4e0d\u9508\u94a2\u6362\u70ed\u5668\uff08\u8010\u9178\u6027\u51b7\u51dd\u6c34\uff09\uff1b\u666e\u901a\u7089\u53ef\u9009\u94dc\u6362\u70ed\u5668\uff08\u6210\u672c\u66f4\u4f4e\uff09\u3002<\/p>\n<h3 class=\"wp-block-heading\">4.3 \u6696\u6c14\u7247\u9009\u578b<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u7279\u70b9<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<td><strong>\u4ee3\u8868\u54c1\u724c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u94a2\u5236\u677f\u5f0f<\/td>\n<td>\u6563\u70ed\u91cf\u5927\u3001\u6c34\u5bb9\u91cf\u5c0f\u3001\u5347\u6e29\u5feb<\/td>\n<td>\u4e3b\u6d41\u9009\u62e9<\/td>\n<td>\u8fea\u8bfa\u3001\u745e\u7279\u683c<\/td>\n<\/tr>\n<tr>\n<td>\u94dc\u94dd\u590d\u5408<\/td>\n<td>\u8010\u8150\u8680\u3001\u5bff\u547d\u957f<\/td>\n<td>\u6c34\u8d28\u8f83\u5dee\u5730\u533a<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u4f4e\u6e29\u6696\u6c14\u7247<\/td>\n<td>\u589e\u52a0\u7247\u6570\uff0c\u964d\u4f4e\u6c34\u6e29\u9700\u6c42<\/td>\n<td>\u642d\u914d\u51b7\u51dd\u7089<\/td>\n<td>\u9700\u8ba1\u7b97\u6563\u70ed\u8d1f\u8377<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6696\u6c14\u7247\u9009\u578b\u8ba1\u7b97\u516c\u5f0f<\/strong>\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5b9e\u9645\u6563\u70ed\u91cf = \u6807\u79f0\u6563\u70ed\u91cf \u00d7 (\u5b9e\u9645\u6e29\u5dee \u00f7 \u6807\u51c6\u6e29\u5dee)^1.3<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\">\u793a\u4f8b\uff1a\u6807\u79f01000W\u6696\u6c14\u7247\uff0c\u4f9b\u6c3455\u2103\uff0c\u56de\u6c3445\u2103\uff0c\u5ba4\u6e2920\u2103 \u2192 \u5b9e\u9645\u6563\u70ed\u91cf\u2248530W\u3002\u51b7\u51dd\u7089\u914d\u6696\u6c14\u7247\u9700\u52a0\u5927\u89c4\u683c\u3002<\/p>\n<h3 class=\"wp-block-heading\">4.4 \u6696\u6c14\u7247\u9ad8\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\uff08DIANORM\u6807\u51c6\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\u6839\u636e\u56fd\u6807GB\/T13754-1992\uff0c\u6807\u51c6\u5de5\u51b5\uff1a\u4f9b\u6c3495\u2103\u3001\u56de\u6c3470\u2103\u3001\u5ba4\u6e2918\u2103\uff0c\u0394Tn=64.5\u2103\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4efb\u610f\u5de5\u51b5\u6362\u7b97\u516c\u5f0f<\/strong>\uff1aQ = Qn \u00d7 (\u0394T \/ 64.5)^n\uff0cn\u53d61.25<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u901f\u67e5<\/strong>\uff08\u6807\u51c6\u6563\u70ed\u91cf1000W\uff09\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5de5\u51b5<\/strong><\/td>\n<td><strong>\u4f9b\u6c34<\/strong><\/td>\n<td><strong>\u56de\u6c34<\/strong><\/td>\n<td><strong>\u5ba4\u6e29<\/strong><\/td>\n<td><strong>\u5b9e\u9645\u6563\u70ed\u91cf<\/strong><\/td>\n<td><strong>\u6298\u7b97\u6bd4\u4f8b<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u5de5\u51b5<\/td>\n<td>95\u2103<\/td>\n<td>70\u2103<\/td>\n<td>18\u2103<\/td>\n<td>1000W<\/td>\n<td>100%<\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u7089\u9ad8\u6e29<\/td>\n<td>80\u2103<\/td>\n<td>60\u2103<\/td>\n<td>20\u2103<\/td>\n<td>760W<\/td>\n<td>76%<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51dd\u7089\u4f4e\u6e29<\/td>\n<td>55\u2103<\/td>\n<td>45\u2103<\/td>\n<td>20\u2103<\/td>\n<td>400W<\/td>\n<td>40%<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u80fd\u4f4e\u6e29<\/td>\n<td>45\u2103<\/td>\n<td>35\u2103<\/td>\n<td>20\u2103<\/td>\n<td>230W<\/td>\n<td>23%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u4f9b\u6c34\u4ece95\u2103\u964d\u81f355\u2103\uff0c\u6563\u70ed\u91cf\u4e0b\u964d\u7ea660%\u3002\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u914d\u6696\u6c14\u7247\u65f6\uff0c\u5fc5\u987b\u6309\u6b64\u6bd4\u4f8b\u589e\u52a0\u89c4\u683c\u3002<\/p>\n<h3 class=\"wp-block-heading\">4.5 \u5206\u96c6\u6c34\u5668\u4e0e\u9600\u95e8\u9009\u578b<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u90e8\u4ef6<\/strong><\/td>\n<td><strong>\u9009\u578b\u8981\u70b9<\/strong><\/td>\n<td><strong>\u63a8\u8350\u6750\u8d28\/\u54c1\u724c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5206\u96c6\u6c34\u5668<\/td>\n<td>\u94dc\u8d28\u4e00\u4f53\u953b\u9020\uff0c\u9600\u82af\u6750\u8d28\u9700\u8010\u7528<\/td>\n<td>\u4f1f\u661f\u3001\u66fc\u745e\u5fb7<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e29\u9600<\/td>\n<td>\u7cbe\u786e\u63a7\u6e29\uff0c\u8010\u8150\u8680<\/td>\n<td>\u5361\u83b1\u83f2<\/td>\n<\/tr>\n<tr>\n<td>\u6696\u6c14\u9600<\/td>\n<td>\u89d2\u5f0f\/\u76f4\u5f0fH\u578b\uff0c\u6697\u88c5\u4e13\u7528<\/td>\n<td>H1\/2M(\u6d3b)*3\/4M<\/td>\n<\/tr>\n<tr>\n<td>\u538b\u5dee\u65c1\u901a\u9600<\/td>\n<td>\u8c03\u8282\u7cfb\u7edf\u538b\u529b\uff0c\u907f\u514d\u9891\u7e41\u542f\u505c<\/td>\n<td>\u6309\u7ba1\u5f84\u9009\u578b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">4.6 \u5730\u6696\u53cd\u5c04\u819c\u9009\u578b<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u5168\u94dd\u53cd\u5c04\u819c\uff08\u63a8\u8350\uff09<\/strong><\/td>\n<td><strong>\u955c\u9762\u9540\u94dd\u819c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u53cd\u5c04\u7387<\/td>\n<td>&gt;95%<\/td>\n<td>&gt;95%\uff08\u521d\u671f\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u8010\u8150\u8680\u6027<\/td>\n<td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u7eaf\u94dd\u8010\u78b1\u8680<\/td>\n<td>\u2b50\u2b50 \u9540\u5c42\u6613\u88ab\u6c34\u6ce5\u8150\u8680\u8131\u843d<\/td>\n<\/tr>\n<tr>\n<td>\u957f\u671f\u7a33\u5b9a\u6027<\/td>\n<td>\u4f18<\/td>\n<td>\u5dee\uff08\u53cd\u5c04\u7387\u8870\u51cf\u5feb\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e94\u90e8\u5206\uff1a\u6545\u969c\u56fe\u8c31\u4e0e\u5b9e\u64cd\u7ef4\u62a4<\/h2>\n<h3 class=\"wp-block-heading\">5.1 \u9891\u7e41\u542f\u505c\u2014\u2014\u6700\u4f18\u5148\u89e3\u51b3\u7684\u95ee\u9898<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u6210\u56e0<\/strong>\uff1a\u529f\u7387\u4e0e\u6d41\u91cf\u53cc\u91cd\u4e0d\u5339\u914d<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u58c1\u6302\u7089\u7ed9\u7684<\/strong><\/td>\n<td><strong>\u5bb6\u91cc\u9700\u8981\u7684<\/strong><\/td>\n<td><strong>\u7ed3\u679c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u529f\u7387<\/td>\n<td>24kW<\/td>\n<td>100\u33a1\u5730\u6696\u6052\u6e29\u4ec55kW<\/td>\n<td>\u529f\u7387\u4e25\u91cd\u8fc7\u5269<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5<\/td>\n<td>\u626c\u7a0b5-6\u7c73<\/td>\n<td>\u9700\u22658\u7c73\u514b\u670d\u5730\u6696\u963b\u529b<\/td>\n<td>\u6d41\u91cf\u4e0d\u8db3<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236<\/td>\n<td>\u6309\u6c34\u6e29\u542f\u505c<\/td>\n<td>\u9700\u6309\u5ba4\u6e29\u63a7\u5236<\/td>\n<td>\u65e0\u6548\u4ea7\u70ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6076\u6027\u5faa\u73af\u8fc7\u7a0b<\/strong>\uff1a<\/p>\n<p class=\"wp-block-paragraph\">\u70b9\u706b\uff0824kW\u6ee1\u529f\u7387\uff09\u2192 \u6c34\u6e29\u5feb\u901f\u8fbe\u6807 \u2192 \u505c\u673a \u2192 \u98ce\u673a\u540e\u5439\u626b+\u5438\u5165\u51b7\u7a7a\u6c14 \u2192 \u6c34\u6e29\u9aa4\u964d \u2192 \u518d\u6b21\u70b9\u706b \u2192 \u5faa\u73af\u5f80\u590d<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6cbb\u6807vs\u6cbb\u672c<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u65b9\u6848<\/strong><\/td>\n<td><strong>\u63aa\u65bd<\/strong><\/td>\n<td><strong>\u6548\u679c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8054\u52a8\u63a7\u5236\uff08\u6cbb\u6807\uff09<\/td>\n<td>\u5ba4\u6e29\u4e0e\u9505\u7089\u8054\u52a8<\/td>\n<td>\u51cf\u5c11\u65e0\u6548\u542f\u505c\uff0c\u4f46\u542f\u52a8\u51b2\u51fb\u4ecd\u5728<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u51b7\u51dd\u7089\uff08\u6cbb\u672c\uff09<\/td>\n<td>\u6700\u5c0f\u8f93\u51fa3-4kW\uff0c\u5168\u53d8\u9891<\/td>\n<td>\u529f\u7387\u4e0e\u8d1f\u8377\u5339\u914d\uff0c\u8fde\u7eed\u8fd0\u884c<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u7a7a\u6c14\u80fd\uff08\u6cbb\u672c\uff09<\/td>\n<td>COP 3.0\uff0c\u5168\u53d8\u9891<\/td>\n<td>\u8fd0\u884c\u8d39\u770140-60%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">5.2 \u4f4e\u6e29\u51b7\u51dd\u6545\u969c\uff08\u666e\u901a\u7089\u4e13\u5c5e\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9879\u76ee<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u73b0\u8c61<\/strong><\/td>\n<td>\u9505\u7089\u62a5\u98ce\u538b\u6545\u969c\uff08E03\uff09\u3001\u70b9\u706b\u5931\u8d25\u3001\u751f\u6d3b\u70ed\u6c34\u5931\u7075<\/td>\n<\/tr>\n<tr>\n<td><strong>\u68c0\u67e5\u53d1\u73b0<\/strong><\/td>\n<td>\u6587\u4e18\u91cc\u7ba1\u53d6\u6837\u53e3\u6216\u8fde\u63a5\u7845\u80f6\u7ba1\u5185\u6709\u6c34\u73e0\u5835\u585e<\/td>\n<\/tr>\n<tr>\n<td><strong>\u539f\u7406<\/strong><\/td>\n<td>\u666e\u901a\u7089\u56de\u6c34\u6e29\u5ea6&lt;60\u2103\u65f6\uff0c\u70df\u6c14\u6e29\u5ea6\u964d\u81f3\u9732\u70b9\u4ee5\u4e0b\uff0c\u4ea7\u751f\u9178\u6027\u51b7\u51dd\u6c34\uff0c\u8150\u8680\u94dc\u5236\u6362\u70ed\u5668\u548c\u6587\u4e18\u91cc\u7ba1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u89e3\u51b3<\/strong><\/td>\n<td>\u666e\u901a\u7089\u6c34\u6e29\u8bbe\u5b9a\u226560\u2103\uff1b\u5347\u7ea7\u51b7\u51dd\u7089\uff1b\u5df2\u5835\u585e\u65f6\u6e05\u6d17\u6587\u4e18\u91cc\u7ba1\u53ca\u7845\u80f6\u7ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">5.3 \u6c34\u529b\u5931\u8c03\u4e0e\u51b7\u70ed\u4e0d\u5747<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9879\u76ee<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u73b0\u8c61<\/strong><\/td>\n<td>\u8fd1\u7aef\u6696\u6c14\u7247\u70ed\u3001\u8fdc\u7aef\u4e0d\u70ed\uff1b\u9505\u7089\u56de\u6c34\u6e29\u5ea6\u8fc7\u9ad8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6839\u6e90<\/strong><\/td>\n<td>\u5f02\u7a0b\u7ba1\u9053\u672a\u505a\u6c34\u529b\u5e73\u8861\uff0c\u6c34\u6d41\u201c\u8d70\u8fd1\u8def\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u89e3\u51b3<\/strong><\/td>\n<td>\u540c\u7a0b\u7ba1\u9053\/\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668\uff1b\u52a0\u88c5\u538b\u5dee\u65c1\u901a\u9600<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">5.4 \u5e38\u89c1\u6545\u969c\u901f\u67e5<\/h3>\n<p class=\"wp-block-paragraph\"><strong>E10\u7f3a\u6c34\u6545\u969c<\/strong>\uff1a\u9505\u7089\u62a5E10\uff0c\u6c34\u538b\u8868\u6307\u9488\u5728\u7ea2\u8272\u533a\u57df \u2192 \u6253\u5f00\u8865\u6c34\u9600\uff0c\u8865\u6c34\u81f31.2-1.5bar<\/p>\n<p class=\"wp-block-paragraph\"><strong>E1\/E4\u8d85\u6e29\u6545\u969c<\/strong>\uff1a\u4e24\u7528\u7089+\u6052\u6e29\u82b1\u6d12\/\u96f6\u51b7\u6c34\uff0c\u8fdb\u7089\u51b7\u6c34\u91cf\u51cf\u5c11 \u2192 \u62c6\u9664\u6052\u6e29\u82b1\u6d12\uff0c\u6216\u91c7\u6696\u70ed\u6c34\u5206\u79bb<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u98ce\u538b\u6545\u969c\uff08E03\uff09<\/strong>\uff1a\u6587\u4e18\u91cc\u7ba1\u5835\u585e\uff08\u51b7\u51dd\u6c34\/\u79ef\u7070\uff09 \u2192 \u6e05\u6d17\u6587\u4e18\u91cc\u7ba1\u53ca\u8fde\u63a5\u7845\u80f6\u7ba1<\/p>\n<h3 class=\"wp-block-heading\">5.5 \u51b7\u51dd\u6c34\u6392\u653e\u7ea2\u7ebf<\/h3>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f <strong>\u4e25\u7981<\/strong>\uff1a\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1\u4f7f\u7528\u91d1\u5c5e\u8f6f\u7ba1\/\u91d1\u5c5e\u7ba1\u9053 \u2705 <strong>\u5fc5\u987b<\/strong>\uff1a\u4f7f\u7528PVC-U\u3001PPR\u7b49\u5851\u6599\u7ba1\u9053\uff0c\u63a5\u5165\u5730\u6f0f<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\">\u539f\u7406\uff1a\u51b7\u51dd\u6c34pH\u22483.5-4.5\uff08\u542b\u786b\u9178\u3001\u78b3\u9178\uff09\uff0c\u5448\u9178\u6027\uff0c\u91d1\u5c5e\u7ba1\u9053\u4f1a\u88ab\u5feb\u901f\u8150\u8680\u7a7f\u5b54\u3002<\/p>\n<h3 class=\"wp-block-heading\">5.6 \u9505\u7089\u5e74\u5ea6\u4fdd\u517b\u5468\u671f\u8868<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4fdd\u517b\u9879\u76ee<\/strong><\/td>\n<td><strong>\u5468\u671f<\/strong><\/td>\n<td><strong>\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u70e7\u5ba4\u6e05\u6d17<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u6e05\u9664\u79ef\u78b3\u3001\u6c27\u5316\u7269<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u673a\u53f6\u8f6e\u6e05\u6d17<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u6e05\u9664\u79ef\u7070<\/td>\n<\/tr>\n<tr>\n<td>\u6587\u4e18\u91cc\u7ba1\u68c0\u67e5<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u9632\u6b62\u5835\u585e\u5bfc\u81f4\u98ce\u538b\u6545\u969c<\/td>\n<\/tr>\n<tr>\n<td>\u706b\u6392\u6e05\u7406<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u6e05\u9664\u6c27\u5316\u7269\uff0c\u4fdd\u8bc1\u706b\u7130\u5747\u5300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u4fdd\u517b\u4ef7\u503c\uff1a\u6e05\u6d17\u540e\u70ed\u6548\u7387\u53ef\u63d0\u5347<strong>20%<\/strong>\uff0c\u6bcf\u67081000\u5143\u71c3\u6c14\u8d39\u53ef\u7701\u7ea6200\u5143\/\u6708\u3002<\/p>\n<h3 class=\"wp-block-heading\">5.7 \u540c\u8f74\u70df\u9053\u96fe\u973e\u79ef\u7070\u4fdd\u517b\u63d0\u9192<\/h3>\n<p class=\"wp-block-paragraph\">\u5e73\u8861\u5f0f\u58c1\u6302\u7089\u4ece<strong>\u5ba4\u5916\u5438\u6c14<\/strong>\uff0c\u96fe\u973e\u5929\u7c89\u5c18\u8fdb\u5165\u71c3\u70e7\u5ba4\uff0c\u9ad8\u6e29\u71c3\u70e7\u540e\u5f62\u6210\u7ed3\u6676\u4f53\u9644\u7740\u3002\u7a7a\u6c14\u6c61\u67d3\u4e25\u91cd\u5730\u533a\uff08\u5982\u6210\u90fd\u51ac\u5b63\uff09\uff0c\u5efa\u8bae<strong>\u6bcf\u5e74\u6e05\u6d17<\/strong>\u3002<\/p>\n<h3 class=\"wp-block-heading\">5.8 \u6696\u6c14\u7247\u6e29\u63a7\u9600\u4e0e\u9505\u7089\u5185\u7f6e\u6cf5\u7684\u5339\u914d<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u95ee\u9898<\/strong>\uff1a\u6696\u6c14\u7247\u5b89\u88c5\u6e29\u63a7\u9600\uff08\u6bd4\u4f8b\u8c03\u8282\uff09\uff0c\u4f46\u9505\u7089\u5185\u7f6e\u6cf5\u4e3a\u5b9a\u9891\u6cf5\u3002\u5f53\u591a\u4e2a\u623f\u95f4\u6e29\u63a7\u9600\u5173\u95ed\u65f6\uff0c\u5269\u4f59\u5f00\u542f\u7684\u6696\u6c14\u7247\u51fa\u73b0\u6c34\u6d41\u566a\u97f3\u3001\u5578\u53eb\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u539f\u7406<\/strong>\uff1a\u5b9a\u9891\u6c34\u6cf5\u8f6c\u901f\u56fa\u5b9a\uff0c\u672b\u7aef\u9600\u95e8\u5173\u5c0f\u2192\u7ba1\u8def\u963b\u529b\u589e\u5927\u2192\u6c34\u6cf5\u626c\u7a0b\u5347\u9ad8\u2192\u9ad8\u626c\u7a0b\u6c34\u6d41\u51b2\u51fb\u534a\u95ed\u9600\u95e8\uff0c\u4ea7\u751f\u201c\u6c34\u9524\u6548\u5e94\u201d\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7c7b\u6bd4<\/strong>\uff1a\u5c31\u50cf\u5927\u98ce\u5929\u628a\u7a97\u6237\u5f00\u4e00\u6761\u5c0f\u7f1d\uff0c\u98ce\u94bb\u8fdb\u6765\u4f1a\u4ea7\u751f\u9707\u52a8\u548c\u5578\u53eb\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u89e3\u51b3\u65b9\u6848<\/strong>\uff1a<\/p>\n<ol class=\"wp-block-list\">\n<li>\u91c7\u7528\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\uff0c\u51cf\u5c11\u9600\u95e8\u8c03\u8282\u9700\u6c42<\/li>\n<li>\u52a0\u88c5\u538b\u5dee\u65c1\u901a\u9600\u6cc4\u538b<\/li>\n<li>\u5347\u7ea7\u53d8\u9891\u51b7\u51dd\u7089\uff08\u5185\u7f6e\u53d8\u9891\u6cf5\uff09<\/li>\n<\/ol>\n<h2 class=\"wp-block-heading\">\u7b2c\u516d\u90e8\u5206\uff1a\u80fd\u8017\u5bf9\u6bd4\u4e0e\u7ecf\u6d4e\u5206\u6790<\/h2>\n<h3 class=\"wp-block-heading\">6.1 \u8ba1\u7b97\u57fa\u51c6<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u53c2\u6570<\/strong><\/td>\n<td><strong>\u53d6\u503c<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u9762\u79ef<\/td>\n<td>100\u33a1<\/td>\n<td>\u6807\u51c6\u6237\u578b<\/td>\n<\/tr>\n<tr>\n<td>\u5355\u4f4d\u4f7f\u7528\u8d1f\u8377<\/td>\n<td>50W\/\u33a1<\/td>\n<td>\u5b9e\u9645\u8fd0\u884c\u5e73\u5747\u8d1f\u8377\uff0c\u975e\u8bbe\u8ba1\u5cf0\u503c<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u4f7f\u7528\u8d1f\u8377<\/td>\n<td>5kW<\/td>\n<td>100\u33a1 \u00d7 50W\/\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u5b63<\/td>\n<td>120\u5929<\/td>\n<td>\u6210\u90fd\u51ac\u5b63\u7ea64\u4e2a\u6708<\/td>\n<\/tr>\n<tr>\n<td>\u8fd0\u884c\u65f6\u95f4<\/td>\n<td>24\u5c0f\u65f6\/\u5929<\/td>\n<td>\u5730\u6696\u5168\u5929\u5f00\u542f<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u4ef7<\/td>\n<td>0.5\u5143\/\u5ea6<\/td>\n<td>\u5c45\u6c11\u7528\u7535\u53c2\u8003\u4ef7<\/td>\n<\/tr>\n<tr>\n<td>\u6c14\u4ef7<\/td>\n<td>2.5\u5143\/\u65b9<\/td>\n<td>\u6210\u90fd\u71c3\u6c14\u9636\u68af\u4ef7\u53d6\u4e2d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">6.2 \u4e09\u79cd\u70ed\u6e90\u8fd0\u884c\u8d39\u7528\u5bf9\u6bd4\uff08100\u33a1\u5730\u6696\uff0c120\u5929\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u70ed\u6e90\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u5b63\u8d39\u7528<\/strong><\/td>\n<td><strong>\u6bd4\u7a7a\u6c14\u80fd\u591a\u82b1<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u7089<\/td>\n<td>3,780\u5143<\/td>\n<td>+1,380\u5143\/\u5e74<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51dd\u7089<\/td>\n<td>3,156\u5143<\/td>\n<td>+756\u5143\/\u5e74<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u80fd\uff08COP3.0\uff09<\/td>\n<td>2,400\u5143<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">6.3 20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9879\u76ee<\/strong><\/td>\n<td><strong>\u666e\u901a\u7089<\/strong><\/td>\n<td><strong>\u51b7\u51dd\u7089<\/strong><\/td>\n<td><strong>\u7a7a\u6c14\u80fd\uff08\u5df2\u6709\u7a7a\u8c03\u52a0\u6c34\u6a21\u5757\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6e90\u521d\u6295\u8d44<\/td>\n<td>8,000\u5143<\/td>\n<td>15,000\u5143<\/td>\n<td>10,500\u5143<\/td>\n<\/tr>\n<tr>\n<td>20\u5e74\u8fd0\u884c\u8d39<\/td>\n<td>85,200\u5143<\/td>\n<td>76,240\u5143<\/td>\n<td>52,960\u5143<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u5907\u66f4\u6362\u8d39<\/td>\n<td>+16,000\u5143<\/td>\n<td>+15,000\u5143<\/td>\n<td>0\u5143<\/td>\n<\/tr>\n<tr>\n<td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td>\n<td><strong>\u7ea6109,200\u5143<\/strong><\/td>\n<td><strong>\u7ea6106,240\u5143<\/strong><\/td>\n<td><strong>\u7ea663,460\u5143<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e03\u90e8\u5206\uff1a\u5b9e\u6218\u65b9\u6848\u4e0e\u5ba2\u6237\u6c9f\u901a<\/h2>\n<h3 class=\"wp-block-heading\">7.1 \u6c9f\u901a\u6846\u67b6\uff1a\u6548\u679c\u2192\u7a33\u5b9a\u2192\u8282\u80fd\u2192\u62a5\u4ef7<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u5f00\u7bc7\u8bdd\u672f<\/strong>\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u8001\u5e08\u4f60\u597d\uff0c\u4f60\u53ef\u80fd\u4f1a\u82b1\u4e00\u5927\u7b14\u8d39\u7528\u4e70\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\uff0c\u65e0\u8bba\u8c01\u600e\u4e48\u627f\u8bfa\uff0c\u4f60\u60f3\u8981\u7684\u6548\u679c\u3001\u662f\u5426\u8fd0\u884c\u7ef4\u4fdd\u65e0\u969c\u788d\uff0c\u4ee5\u53ca\u7528\u8d77\u6765\u80fd\u5426\u6bd4\u90bb\u5c45\u5bb6\u66f4\u7701\uff0c\u4e00\u5207\u4ecd\u7136\u672a\u77e5\u3002\u4f46\u6211\u4eec\u53ef\u4ee5\u628a\u672a\u77e5\u53d8\u5f97\u53ef\u9884\u89c1\u2026\u2026\u201d<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">7.2 \u6838\u5fc3\u8bdd\u672f\u5e93<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u51b7\u51dd\u7089\u6548\u7387108%\u662f\u4e0d\u662f\u865a\u5047\u5ba3\u4f20\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c108%\u662f\u6309\u884c\u4e1a\u901a\u7528\u7684\u4f4e\u70ed\u503c\u6807\u51c6\u7b97\u51fa\u6765\u7684\u3002\u6309\u771f\u5b9e\u603b\u70ed\u91cf\u7b97\uff0c\u51b7\u51dd\u7089\u6548\u7387\u7ea697%\uff0c\u6c38\u4e0d\u8d85100%\u3002\u8fd9\u4e2a108%\u7684\u610f\u601d\u662f\u2014\u2014\u5b83\u6bd4\u666e\u901a\u7089\u591a\u56de\u6536\u4e86\u70df\u6c14\u4e2d\u6c34\u84b8\u6c14\u7684\u70ed\u91cf\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u5f00\u4e00\u7ec4\u6bd4\u5f00\u591a\u7ec4\u66f4\u8d39\u6c14\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u9505\u7089\u6700\u5c0f\u8f93\u51fa8-10kW\uff0c\u53ea\u5f00\u4e00\u7ec4\u6696\u6c14\u7247\u53ea\u80fd\u6d88\u80172kW\uff0c\u591a\u4f59\u70ed\u91cf\u65e0\u5904\u53ef\u53bb\uff0c\u9505\u7089\u9891\u7e41\u542f\u505c\u3002\u6bcf\u6b21\u542f\u52a8\u6ee1\u529f\u738724kW\uff0c\u767d\u767d\u6d6a\u8d39\u71c3\u6c14\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u51b7\u51dd\u7089\u914d\u666e\u901a\u6696\u6c14\u7247\u80fd\u7701\u6c14\u5417\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u51b7\u51dd\u7089\u5fc5\u987b\u5728\u4f4e\u6e29\u5de5\u51b5\u4e0b\u624d\u80fd\u53d1\u6325\u4f18\u52bf\u3002\u5982\u679c\u914d\u666e\u901a\u6696\u6c14\u7247\uff0c\u6c34\u6e29\u9700\u8981\u70e7\u523070-80\u2103\uff0c\u51b7\u51dd\u7089\u8ddf\u666e\u901a\u7089\u6ca1\u533a\u522b\uff0c\u591a\u82b1\u7684\u94b1\u767d\u82b1\u4e86\u3002\u6240\u4ee5\u88c5\u51b7\u51dd\u7089\uff0c\u8981\u4e48\u914d\u5730\u6696\uff0c\u8981\u4e48\u914d\u4f4e\u6e29\u6696\u6c14\u7247\u3002\u201d<\/p>\n<\/blockquote>\n<h2 class=\"wp-block-heading\">\u7b2c\u516b\u90e8\u5206\uff1a\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/h2>\n<h3 class=\"wp-block-heading\">8.1 \u91c7\u6696\u7cfb\u7edf\u5e38\u89c1\u552e\u540e\u95ee\u9898<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898\u73b0\u8c61<\/strong><\/td>\n<td><strong>\u53ef\u80fd\u539f\u56e0<\/strong><\/td>\n<td><strong>\u6392\u67e5\u65b9\u5411<\/strong><\/td>\n<td><strong>\u89e3\u51b3\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u8d39\u7528\u6781\u9ad8<\/td>\n<td>\u9505\u7089\u529f\u7387\u8d85\u914d\u3001\u65e0\u5ba4\u6e29\u8054\u52a8\u3001\u6c34\u529b\u5931\u8861<\/td>\n<td>\u68c0\u67e5\u9505\u7089\u529f\u7387\u3001\u63a7\u5236\u65b9\u5f0f\u3001\u5404\u56de\u8def\u6e29\u5dee<\/td>\n<td>\u964d\u529f\u7387\u3001\u52a0\u8054\u52a8\u3001\u8c03\u5e73\u8861<\/td>\n<\/tr>\n<tr>\n<td>\u9505\u7089\u9891\u7e41\u542f\u505c<\/td>\n<td>\u6700\u5c0f\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u5bb9\u91cf\u8fc7\u5c0f<\/td>\n<td>\u68c0\u67e5\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u3001\u7cfb\u7edf\u6c34\u91cf<\/td>\n<td>\u6362\u51b7\u51dd\u7089\u3001\u52a0\u7f13\u51b2\u6c34\u7bb1<\/td>\n<\/tr>\n<tr>\n<td>\u623f\u95f4\u51b7\u70ed\u4e0d\u5747<\/td>\n<td>\u5f02\u7a0b\u6c34\u529b\u5931\u8861\u3001\u56de\u8def\u8bbe\u8ba1\u4e0d\u5408\u7406<\/td>\n<td>\u6d4b\u91cf\u5404\u56de\u8def\u56de\u6c34\u6e29\u5ea6<\/td>\n<td>\u8c03\u8282\u5206\u6c34\u5668\u9600\u95e8\u3001\u6539\u9020\u540c\u7a0b<\/td>\n<\/tr>\n<tr>\n<td>\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb<\/td>\n<td>\u9505\u7089\u6700\u5c0f\u529f\u7387\u8fc7\u9ad8<\/td>\n<td>\u68c0\u67e5\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/td>\n<td>\u6362\u5206\u6bb5\u71c3\u70e7\u7089\u3001\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u538b\u529b\u5f02\u5e38<\/td>\n<td>\u7ba1\u9053\u6e17\u6f0f\u3001\u81a8\u80c0\u6c34\u7bb1\u5931\u6548<\/td>\n<td>\u89c2\u5bdf\u538b\u529b\u53d8\u5316\u89c4\u5f8b<\/td>\n<td>\u67e5\u6f0f\u8865\u6f0f\u3001\u66f4\u6362\u81a8\u80c0\u7f50<\/td>\n<\/tr>\n<tr>\n<td>\u9ed1\u6c34\u5f02\u5473<\/td>\n<td>\u975e\u963b\u6c27\u7ba1+\u9ad8\u6e29+\u6df7\u5408\u91d1\u5c5e<\/td>\n<td>\u653e\u6c34\u89c2\u5bdf\u989c\u8272<\/td>\n<td>\u7cfb\u7edf\u6e05\u6d17\u3001\u52a0\u4fdd\u62a4\u5242\u3001\u5347\u7ea7\u963b\u6c27\u7ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">8.2 \u7cfb\u7edf\u6027\u95ee\u9898\u6839\u6e90\uff08\u8bbe\u8ba1\u9636\u6bb5\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898\u6839\u6e90<\/strong><\/td>\n<td><strong>\u552e\u540e\u8868\u73b0<\/strong><\/td>\n<td><strong>\u8bbe\u8ba1\u9636\u6bb5\u9884\u9632\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u9505\u7089\u529f\u7387\u4e25\u91cd\u8d85\u914d<\/td>\n<td>\u9891\u7e41\u542f\u505c\u3001\u80fd\u8017\u98d9\u534720-30%<\/td>\n<td>\u6309\u70ed\u8d1f\u8377\u9009\u578b\uff0c\u6821\u6838\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u529b\u5931\u8861<\/td>\n<td>\u8fd1\u7aef\u70ed\u8fdc\u7aef\u51c9<\/td>\n<td>\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\uff0c\u5408\u7406\u5212\u5206\u56de\u8def<\/td>\n<\/tr>\n<tr>\n<td>\u65e0\u5ba4\u6e29\u8054\u52a8<\/td>\n<td>\u5ba4\u6e29\u8fbe\u6807\u9505\u7089\u4ecd\u8fd0\u884c<\/td>\n<td>\u5f3a\u5236\u6807\u914d\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u975e\u963b\u6c27\u7ba1\u7528\u4e8e\u9ad8\u6e29\u7cfb\u7edf<\/td>\n<td>\u9ed1\u6c34\u3001\u8150\u8680\u3001\u6f0f\u6c34<\/td>\n<td>\u6c34\u6e29\u226550\u2103\u6216\u6df7\u5408\u91d1\u5c5e\u5f3a\u5236\u963b\u6c27<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u5f84\u8bbe\u8ba1\u504f\u5c0f<\/td>\n<td>\u6d41\u91cf\u4e0d\u8db3\u3001\u6548\u679c\u5dee<\/td>\n<td>\u6309\u7ba1\u5f84\u6d41\u91cf\u901f\u67e5\u8868\u9009\u578b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">8.3 \u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u4fdd\u9879\u76ee<\/strong><\/td>\n<td><strong>\u5468\u671f<\/strong><\/td>\n<td><strong>\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u6c34\u8d28\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u653e\u6c34\u89c2\u5bdf\u989c\u8272\uff0c\u5224\u65ad\u8150\u8680\u7a0b\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u8fc7\u6ee4\u5668\u6e05\u6d17<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u6e05\u6d17\u56de\u6c34\u8fc7\u6ee4\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u9505\u7089\u71c3\u70e7\u5ba4\u6e05\u6d17<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u6e05\u9664\u79ef\u78b3\u3001\u6c27\u5316\u7269<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u673a\u53f6\u8f6e\u6e05\u6d17<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u6e05\u9664\u79ef\u7070<\/td>\n<\/tr>\n<tr>\n<td>\u6587\u4e18\u91cc\u7ba1\u68c0\u67e5<\/td>\n<td>1-2\u5e74<\/td>\n<td>\u9632\u6b62\u5835\u585e\u5bfc\u81f4\u98ce\u538b\u6545\u969c<\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u80c0\u7f50\u538b\u529b\u68c0\u6d4b<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u9884\u5145\u538b\u529b<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u6e29\u8054\u52a8\u529f\u80fd\u6d4b\u8bd5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u786e\u8ba4\u6e29\u63a7\u5668\u80fd\u6b63\u5e38\u542f\u505c\u9505\u7089<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">8.4 \u58c1\u6302\u7089\u6545\u969c\u4ee3\u7801\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4ee3\u7801<\/strong><\/td>\n<td><strong>\u542b\u4e49<\/strong><\/td>\n<td><strong>\u6392\u67e5\u65b9\u5411<\/strong><\/td>\n<\/tr>\n<tr>\n<td>E10<\/td>\n<td>\u7f3a\u6c34\/\u6c34\u538b\u8fc7\u4f4e<\/td>\n<td>\u8865\u6c34\u81f31.2-1.5bar<\/td>\n<\/tr>\n<tr>\n<td>E03<\/td>\n<td>\u98ce\u538b\u6545\u969c<\/td>\n<td>\u68c0\u67e5\u6587\u4e18\u91cc\u7ba1\u3001\u7845\u80f6\u7ba1\u3001\u70df\u9053<\/td>\n<\/tr>\n<tr>\n<td>E01\/E04<\/td>\n<td>\u8d85\u6e29\u6545\u969c<\/td>\n<td>\u68c0\u67e5\u5faa\u73af\u6cf5\u3001\u8fc7\u6ee4\u5668\u3001\u9600\u95e8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u9644\u5f55\uff1a\u5173\u952e\u6570\u636e\u3001\u516c\u5f0f\u4e0e\u89c4\u8303<\/h2>\n<h3 class=\"wp-block-heading\">A. \u5173\u952e\u516c\u5f0f<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u516c\u5f0f<\/strong><\/td>\n<td><strong>\u7528\u9014<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u51fa\u6c34\u91cf(L\/min) = 0.86 \u00d7 \u529f\u7387(kW) \u00d7 1000 \u00d7 \u70ed\u6548\u7387 \u00f7 \u6e29\u5dee(\u2103) \u00f7 60<\/td>\n<td>\u58c1\u6302\u7089\u70ed\u6c34\u80fd\u529b\u901f\u7b97<\/td>\n<\/tr>\n<tr>\n<td>V\u6df7\u5408 = V\u50a8\u70ed \u00d7 (T\u50a8\u70ed - T\u51b7\u6c34) \u00f7 (T\u76ee\u6807 - T\u51b7\u6c34)<\/td>\n<td>\u6052\u6e29\u9600\u6269\u5bb9\u91cf<\/td>\n<\/tr>\n<tr>\n<td>\u771f\u5b9e\u6548\u7387 \u2248 \u6807\u79f0\u6548\u7387 \u00d7 0.9<\/td>\n<td>\u70ed\u6548\u7387\u6362\u7b97<\/td>\n<\/tr>\n<tr>\n<td>Q = Qn \u00d7 (\u0394T \/ 64.5)^1.25<\/td>\n<td>\u6696\u6c14\u7247\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">B. \u80fd\u8017\u901f\u67e5\uff08100\u33a1\u5730\u6696\uff0c120\u5929\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u70ed\u6e90<\/strong><\/td>\n<td><strong>\u5b63\u8d39\u7528<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u7089<\/td>\n<td>3,780\u5143<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51dd\u7089<\/td>\n<td>3,156\u5143<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u80fd<\/td>\n<td>2,400\u5143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">C. \u672f\u8bed\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u672f\u8bed<\/strong><\/td>\n<td><strong>\u89e3\u91ca<\/strong><\/td>\n<\/tr>\n<tr>\n<td>LHV<\/td>\n<td>\u4f4e\u4f4d\u70ed\u503c\uff0c\u884c\u4e1a\u901a\u7528\u6548\u7387\u8ba1\u7b97\u57fa\u51c6<\/td>\n<\/tr>\n<tr>\n<td>HHV<\/td>\n<td>\u9ad8\u4f4d\u70ed\u503c\uff0c\u771f\u5b9e\u603b\u70ed\u91cf<\/td>\n<\/tr>\n<tr>\n<td>COP<\/td>\n<td>\u80fd\u6548\u6bd4\uff0c\u5236\u70ed\u91cf\u00f7\u8f93\u5165\u529f\u7387<\/td>\n<\/tr>\n<tr>\n<td>\u53cc\u51b7\u51dd<\/td>\n<td>\u745e\u7f8e\u4e13\u5229\uff0c\u91c7\u6696+\u70ed\u6c34\u5747\u5b9e\u73b0\u51b7\u51dd\u56de\u6536<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u91cf\u4f3a\u670d\u5668<\/td>\n<td>\u6052\u6e29\u70ed\u6c34\u5668\u6838\u5fc3\u90e8\u4ef6\uff0c\u81ea\u52a8\u8c03\u8282\u6c34\u6d41\u91cf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">D. \u745e\u7f8e\u53cc\u51b7\u51dd\u7089\u6280\u672f\u89e3\u6790<\/h3>\n<p class=\"wp-block-paragraph\">\u745e\u7f8e\u51b7\u51dd\u7089\u91c7\u7528<strong>\u4e8c\u5408\u4e00\u6362\u70ed\u5668<\/strong>\uff08\u4e3b\u6362\u70ed\u5668\u540c\u65f6\u7528\u4e8e\u91c7\u6696\u548c\u70ed\u6c34\uff09\uff0c\u65e0\u9700\u677f\u5f0f\u6362\u70ed\u5668\u4e8c\u6b21\u6362\u70ed\u3002\u76f8\u6bd4\u666e\u901a\u51b7\u51dd\u7089\uff08\u91c7\u6696\u53ef\u51b7\u51dd\u3001\u70ed\u6c34\u4e0d\u53ef\u51b7\u51dd\uff09\uff0c\u745e\u7f8e\u5b9e\u73b0<strong>365\u5929\u5168\u5de5\u51b5\u51b7\u51dd\u8282\u80fd<\/strong>\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u666e\u901a\u51b7\u51dd\u7089<\/strong><\/td>\n<td><strong>\u745e\u7f8e\u53cc\u51b7\u51dd\u7089<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u51b7\u51dd<\/td>\n<td>\u2705 \u652f\u6301<\/td>\n<td>\u2705 \u652f\u6301<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51b7\u51dd<\/td>\n<td>\u274c \u4e0d\u652f\u6301<\/td>\n<td>\u2705 \u652f\u6301\uff08\u4e8c\u5408\u4e00\u6362\u70ed\u5668\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u8282\u80fd<\/td>\n<td>\u4ec5\u91c7\u6696\u5b63\u8282\u80fd<\/td>\n<td><strong>365\u5929\u5168\u5e74\u8282\u80fd<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">E. \u4ea4\u53c9\u5f15\u7528\u7d22\u5f15<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4e3b\u9898<\/strong><\/td>\n<td><strong>\u672c\u624b\u518c\u4f4d\u7f6e<\/strong><\/td>\n<td><strong>\u8be6\u7ec6\u5185\u5bb9\u53c2\u89c1<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u5b8c\u6574\u5bf9\u6bd4<\/td>\n<td>\u7b2c\u516d\u90e8\u5206<\/td>\n<td><a href=\"?page_id=667\"><strong>01\u53f7\u624b\u518c<\/strong> \u7b2c\u4e03\u90e8\u5206<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u6c34\u5730\u6c34\u7cfb\u7edf\u6df1\u5ea6\u89e3\u6790<\/td>\n<td>\u2014<\/td>\n<td><a href=\"?page_id=671\"><strong>03\u53f7\u624b\u518c<\/strong> \u5168\u518c<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u91c7\u6696\u5347\u7ea7\uff09<\/td>\n<td>\u2014<\/td>\n<td><a href=\"?page_id=673\"><strong>04\u53f7\u624b\u518c<\/strong> \u5168\u518c<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u8d85\u914d\u7387\u516d\u7ef4\u5ea6\u5206\u6790<\/td>\n<td>\u2014<\/td>\n<td><a href=\"?page_id=667\"><strong>01\u53f7\u624b\u518c<\/strong> 3.5<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">F. \u76f8\u5173\u4e13\u9898\uff08\u5185\u94fe\u5bfc\u822a\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\u672c\u624b\u518c\u6d89\u53ca\u7684\u70ed\u6e90\u54c1\u724c\u3001\u673a\u578b\u4e0e\u9009\u578b\u4e13\u9898\uff0c\u6309\u4e3b\u9898\u6c47\u603b\u5982\u4e0b\uff0c\u65b9\u4fbf\u7ee7\u7eed\u5f80\u4e0b\u8bfb\u3002<\/p>\n<style>\n.lm-hub{display:grid;grid-template-columns:repeat(auto-fill,minmax(210px,1fr));gap:10px;margin:12px 0;}\n.lm-hub a{display:block;background:#fff;border:1px solid #d8e3e0;border-radius:9px;padding:11px 13px;color:#1f4d45;text-decoration:none;font-size:14px;font-weight:600;transition:.2s;}\n.lm-hub a:hover{border-color:#E8541E;box-shadow:0 2px 10px rgba(232,84,30,.12);}\n.lm-hub a span{display:block;font-weight:400;font-size:12px;color:#647b76;margin-top:3px;}\n<\/style>\n<h4 class=\"wp-block-heading\">F.1 \u6211\u4eec\u505a\u7684\u58c1\u6302\u7089\u54c1\u724c\u4e0e\u673a\u578b<\/h4>\n<div class=\"lm-hub\">\n  <a href=\"?page_id=835\">\u535a\u4e16\u58c1\u6302\u7089<span>\u51b7\u51dd\u7089 + \u5e38\u89c4\u7089\u5168\u7cfb\u5217\u89e3\u6790<\/span><\/a><br \/>\n  <a href=\"?page_id=1824\">\u83f2\u65af\u66fc\u58c1\u6302\u7089<span>\u5fb7\u7cfb\u51b7\u51dd\u6280\u672f \u00b7 \u91c7\u6696\u7cfb\u7edf\u8be6\u60c5<\/span><\/a><br \/>\n  <a href=\"?page_id=1841\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089<span>\u51b7\u51dd\u7089 \/ \u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217<\/span><\/a><br \/>\n  <a href=\"?page_id=2489\">\u6797\u5185\u58c1\u6302\u7089<span>\u666e\u901a\u7089 &amp; \u51b7\u51dd\u7089\u9009\u578b\u5b89\u88c5<\/span><\/a><br \/>\n  <a href=\"?page_id=2553\">\u83f2\u65af\u66fc VITODENS 100-C B1JG<span>\u56fd\u4ea7\u51b7\u51dd\u7089 25kW \u673a\u578b\u9875<\/span><\/a><br \/>\n  <a href=\"?page_id=3533\">\u83f2\u65af\u66fc A1JE \u666e\u901a\u4e24\u7528\u7089<span>\u4e24\u7528\u7089\u673a\u578b\u8be6\u60c5\u9875<\/span><\/a><br \/>\n  <a href=\"?page_id=4499\">\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089 N1PB18-HI.Pro<span>\u7269\u8054\u7f51\u6570\u5b57\u58c1\u6302\u7089<\/span><\/a><br \/>\n  <a href=\"?page_id=7648\">OTT \u6b27\u7279 \u00b7 \u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668<span>\u5927\u6c34\u91cf\u50a8\u70ed\u5f0f\u70ed\u6c34\u65b9\u6848<\/span><\/a>\n<\/div>\n<h4 class=\"wp-block-heading\">F.2 \u70ed\u6e90\u9009\u578b\u4e0e\u5bf9\u6bd4<\/h4>\n<div class=\"lm-hub\">\n  <a href=\"?page_id=11074\">\u58c1\u6302\u7089\u600e\u4e48\u9009<span>\u51b7\u51dd\/\u5e38\u89c4 \u00b7 \u529f\u7387 \u00b7 \u54c1\u724c\u6a2a\u8bc4<\/span><\/a><br \/>\n  <a href=\"?page_id=12812\">\u51b7\u51dd\u7089\u548c\u666e\u901a\u7089\u600e\u4e48\u9009<span>\u6548\u7387 \u00b7 \u6210\u672c \u00b7 \u9002\u7528\u8fb9\u754c<\/span><\/a><br \/>\n  <a href=\"?page_id=13489\">\u5355\u91c7\u6696\u7089\u600e\u4e48\u9009<span>\u5730\u6696\u4e0e\u660e\u88c5\u6696\u6c14\u9009\u578b<\/span><\/a><br \/>\n  <a href=\"?page_id=12776\">\u8001\u623f\u660e\u88c5\u6696\u6c14\u600e\u4e48\u9009\u7089<span>\u5c0f\u529f\u7387\u53d8\u9891\u7089\u4e0d\u9891\u7e41\u542f\u505c<\/span><\/a><br \/>\n  <a href=\"?page_id=3415\">\u5730\u6696\u70ed\u6e90\u6df1\u5ea6\u5bf9\u6bd4<span>\u65e5\u7acb\u6c34\u6a21\u5757 vs \u5a01\u80fd\/\u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/span><\/a><br \/>\n  <a href=\"?page_id=5601\">\u4e8c\u8054\u4f9b vs \u51b7\u51dd\u7089 + \u8282\u80fd\u5730\u6696<span>\u8fd0\u884c\u8d39\u4e0e\u521d\u88c5\u5bf9\u6bd4<\/span><\/a><br \/>\n  <a href=\"?page_id=3415\">\u6c34\u6a21\u5757\u5730\u6696 vs \u9505\u7089\u5e26\u5730\u6696<span>\u53cc\u65b9\u6848\u5b9e\u6d4b\u5bf9\u6bd4<\/span><\/a><br \/>\n  <a href=\"?page_id=3872\">\u4e24\u7528\u58c1\u6302\u7089\u5de5\u4f5c\u539f\u7406<span>\u4e09\u8def\u8054\u52a8\u4e0e\u8fd0\u884c\u6a21\u5f0f<\/span><\/a><br \/>\n  <a href=\"?page_id=13941\">\u71c3\u6c14\u58c1\u6302\u7089\u548c\u70ed\u6c34\u5668\u54ea\u4e2a\u597d<span>\u4e24\u7528\u7089\u6362\u70ed\u6c34\u5668\u4f1a\u4e0d\u4f1a\u964d\u7ea7<\/span><\/a>\n<\/div>\n<h4 class=\"wp-block-heading\">F.3 \u7a7a\u6c14\u80fd \u00b7 \u70ed\u6cf5 \u00b7 \u6c34\u7cfb\u7edf\u70ed\u6e90<\/h4>\n<div class=\"lm-hub\">\n  <a href=\"?page_id=9647\">\u7a7a\u6c14\u80fd\u70ed\u6cf5\u91c7\u6696\u6848\u4f8b<span>\u65e5\u7acb\u65b0\u667a\u4eab 160 \u00b7 \u6c84\u5cb8\u53f6\u8001\u5e08\u5bb6<\/span><\/a><br \/>\n  <a href=\"?page_id=10753\">\u7a7a\u6c14\u6e90\u70ed\u6cf5\u4e24\u8054\u4f9b\u5730\u6696<span>\u9f99\u6e56\u4e09\u5343\u4e91\u9526\u53e0\u62fc\u6848\u4f8b<\/span><\/a><br \/>\n  <a href=\"?page_id=12165\">\u7ebd\u6069\u6cf0\u7a7a\u6c14\u80fd\u70ed\u6c34\u5668<span>+ \u5a01\u4e50\u5faa\u73af\u6cf5\u5b89\u88c5\u5b9e\u5f55<\/span><\/a><br \/>\n  <a href=\"?page_id=1957\">\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e00\u4f53\u5f0f\u4e24\u8054\u4f9b<span>\u5168\u7ef4\u8be6\u60c5\u9875<\/span><\/a><br \/>\n  <a href=\"?page_id=7545\">\u5c0a\u777f\u5168\u6548\u2161\u4e94\u6052\u4e3b\u673a<span>\u5929\u6c1f\u5730\u6c34\u6838\u5fc3\u8be6\u89e3<\/span><\/a><br \/>\n  <a href=\"?page_id=7550\">\u6c34\u5885\u9002\u4e94\u6052\u4e3b\u673a<span>\u5929\u6c34\u5730\u6c34\u6838\u5fc3\u8be6\u89e3<\/span><\/a><br \/>\n  <a href=\"?page_id=7512\">\u5929\u6c1f\u5730\u6c34 vs \u5929\u6c34\u5730\u6c34<span>\u4e24\u8054\u4f9b\u4e94\u6052\u600e\u4e48\u9009<\/span><\/a>\n<\/div>\n<h4 class=\"wp-block-heading\">F.4 \u4ef7\u683c\u4e0e\u670d\u52a1<\/h4>\n<div class=\"lm-hub\">\n  <a href=\"?page_id=11082\">\u58c1\u6302\u7089\u578b\u53f7\u4ef7\u683c\u660e\u7ec6<span>\u83f2\u65af\u66fc \/ \u535a\u4e16 \/ \u66fc\u745e\u5fb7\u4ef7\u76ee<\/span><\/a><br \/>\n  <a href=\"?page_id=10977\">\u5730\u6696\u53c2\u8003\u4ef7\u683c<span>\u6e05\u6c34\u623f \/ \u7cbe\u88c5\u623f\u53c2\u8003\u5355\u4ef7<\/span><\/a><br \/>\n  <a href=\"?page_id=10982\">\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c<span>\u542b\u9505\u7089\u5957\u9910\u4e0e\u6539\u88c5\u9884\u7b97<\/span><\/a><br \/>\n  <a href=\"?page_id=10975\">\u4e24\u8054\u4f9b\u53c2\u8003\u4ef7\u683c<span>\u5929\u6c1f\u5730\u6c34 \u00b7 \u6c34\u5885\u9002\u9884\u7b97<\/span><\/a><br \/>\n  <a href=\"?page_id=14057\">\u6696\u901a\u552e\u540e\u670d\u52a1\u4ef7\u683c\u8868<span>\u58c1\u6302\u7089 \u00b7 \u6696\u6c14\u7247 \u00b7 \u5730\u6696\u7ef4\u4fdd<\/span><\/a><br \/>\n  <a href=\"?page_id=625\">\u670d\u52a1\u4fdd\u969c<span>\u53ef\u89c6\u5316\u5ba2\u6237\u6863\u6848\u4e0e\u627f\u8bfa<\/span><\/a>\n<\/div>\n<h2 class=\"wp-block-heading\">\u91c7\u6696\u4e0e\u70ed\u6c34\u5e38\u89c1\u95ee\u9898<\/h2>\n<details class=\"faq\">\n<summary>\u5730\u6696\u548c\u6696\u6c14\u7247\uff0c\u6210\u90fd\u5bb6\u91cc\u8be5\u600e\u4e48\u9009\uff1f<\/summary>\n<p>\u5730\u6696\u4ece\u5730\u9762\u5f80\u4e0a\u6563\u70ed\uff0c\u811a\u611f\u5747\u5300\u3001\u5ba4\u6e29\u7a33\u5b9a\uff0c\u9002\u5408\u8fd8\u5728\u88c5\u4fee\u9636\u6bb5\u3001\u5c42\u9ad8\u5145\u88d5\u7684\u65b0\u623f\uff1b\u6696\u6c14\u7247\u5347\u6e29\u5feb\u3001\u53ef\u4ee5\u660e\u88c5\u3001\u6539\u9020\u65b9\u4fbf\uff0c\u5df2\u7ecf\u5165\u4f4f\u6216\u8005\u8001\u623f\u52a0\u88c5\u66f4\u7701\u4e8b\u3002\u6bdb\u576f\u65b0\u623f\u4f18\u5148\u8003\u8651\u5730\u6696\uff1b\u8001\u623f\u660e\u88c5\u6696\u6c14\u7247\u4e0d\u52a8\u5730\u9762\u3001\u65bd\u5de5\u66f4\u5feb\u3002\u540c\u4e00\u5957\u623f\u4e5f\u80fd\u5206\u533a\u642d\u914d\uff0c\u5ba2\u5385\u5730\u6696\u3001\u5367\u5ba4\u6696\u6c14\u7247\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u6210\u90fd\u88c5\u5730\u6696\uff0c\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\uff1f<\/summary>\n<p>\u4e24\u79cd\u90fd\u5e38\u89c1\u3002\u666e\u901a\u7089\u771f\u5b9e\u70ed\u6548\u7387 80% \u5230 84%\uff0c\u8bbe\u5907\u521d\u6295\u8d44\u8f83\u4f4e\uff08\u5e38\u89c1 7,000 \u5230 9,000 \u5143\uff09\uff1b\u51b7\u51dd\u7089\u771f\u5b9e\u70ed\u6548\u7387 93% \u5230 97%\uff0c\u7528\u6c14\u66f4\u7701\uff0c\u521d\u6295\u8d44\u66f4\u9ad8\uff08\u5e38\u89c1 13,000 \u5230 16,000 \u5143\uff09\u3002\u91c7\u6696\u5b63\u957f\u3001\u623f\u5b50\u81ea\u4f4f\u591a\u5e74\uff0c\u51b7\u51dd\u7089\u66f4\u5bb9\u6613\u628a\u591a\u82b1\u7684\u94b1\u7701\u56de\u6765\uff1b\u7528\u5f97\u5c11\u3001\u9884\u7b97\u7d27\uff0c\u666e\u901a\u7089\u66f4\u5212\u7b97\u3002\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u5341\u51e0\u4e2a\u767e\u5206\u70b9\uff0c\u770b\u300a\u58c1\u6302\u7089\u6280\u672f\u8bfb\u672c\u300b\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>100\u33a1 \u7684\u623f\u5b50\uff0c\u4e00\u4e2a\u51ac\u5929\u91c7\u6696\u5927\u6982\u82b1\u591a\u5c11\u94b1\uff1f<\/summary>\n<p>\u8ddf\u70ed\u6e90\u3001\u4fdd\u6e29\u3001\u8bbe\u5b9a\u6e29\u5ea6\u548c\u4f7f\u7528\u65f6\u957f\u90fd\u6709\u5173\u7cfb\u3002\u6309 100\u33a1 \u5730\u6696\u3001120 \u5929\u91c7\u6696\u5b63\u4f30\u7b97\uff1a\u666e\u901a\u7089\u7ea6 3,780 \u5143\u3001\u51b7\u51dd\u7089\u7ea6 3,156 \u5143\u3001\u7a7a\u6c14\u80fd\u6309 COP 3.0 \u7ea6 2,400 \u5143\u3002\u8fd9\u662f\u6309\u6210\u90fd\u5178\u578b\u6761\u4ef6\u7b97\u7684\u8d26\uff0c\u5b9e\u9645\u4f1a\u56e0\u4fdd\u6e29\u3001\u5c42\u9ad8\u3001\u5f00\u5173\u7a97\u4e60\u60ef\u4e0a\u4e0b\u6d6e\u52a8\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u5730\u6696\u7ba1\u7528\u591a\u7c97\u7684\uff0c\u5355\u8def\u80fd\u76d8\u591a\u957f\uff1f<\/summary>\n<p>\u6c34\u7cfb\u7edf\u4e3b\u7ba1\u4e0d\u5c0f\u4e8e De32\uff0c\u652f\u7ba1\u4e0d\u5c0f\u4e8e De20\uff0c\u5355\u8def\u957f\u5ea6\u4e0d\u8d85\u8fc7 120 \u7c73\uff0c\u8fd9\u662f JGJ 142-2012 \u7684\u89c4\u5b9a\u3002\u7ba1\u5f84\u7ec6\u4e86\u6d41\u91cf\u4e0d\u591f\uff0c\u70ed\u62c9\u4e0d\u8d70\uff0c\u70ed\u6e90\u70e7\u5f97\u518d\u8db3\u5bb6\u91cc\u8fd8\u662f\u4e0d\u70ed\uff1b\u5355\u8def\u8fc7\u957f\uff0c\u672b\u7aef\u90a3\u51e0\u7c73\u6c34\u6e29\u5df2\u7ecf\u6389\u4e0b\u6765\uff0c\u623f\u95f4\u51b7\u70ed\u4e0d\u5747\u3002\u76d8\u7ba1\u95f4\u8ddd\u901a\u914d 150 \u6beb\u7c73\uff0c\u8282\u80fd\u505a\u6cd5 125 \u6beb\u7c73\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u8001\u623f\u80fd\u88c5\u6696\u6c14\u5417\uff0c\u8981\u51e0\u5929\uff1f<\/summary>\n<p>\u80fd\uff0c\u8d70\u660e\u88c5\u6696\u6c14\u7247\uff1a\u7ba1\u9053\u8d70\u8e22\u811a\u7ebf\u3001\u95e8\u6846\u8fb9\u3001\u540a\u9876\u9634\u89d2\uff0c\u4e0d\u7838\u5730\u9762\u3001\u4e0d\u7834\u574f\u88c5\u4fee\uff0c\u4e00\u822c\u4e24\u5230\u4e09\u5929\u88c5\u5b8c\uff0c\u88c5\u5b8c\u5f53\u5929\u5c31\u80fd\u7528\u3002\u8001\u623f\u88c5\u4e4b\u524d\u8981\u5148\u770b\u4e09\u4ef6\u4e8b\uff1a\u5916\u673a\u4f4d\u548c\u70df\u9053\u4f4d\u7f6e\u591f\u4e0d\u591f\u3001\u71c3\u6c14\u8868\u5bb9\u91cf\u591f\u4e0d\u591f\u3001\u6696\u6c14\u7247\u6446\u4f4d\u4f1a\u4e0d\u4f1a\u6321\u5bb6\u5177\u548c\u7a97\u5e18\u3002\u8fd9\u4e09\u4ef6\u4e8b\u73b0\u573a\u770b\u4e00\u773c\u5c31\u6e05\u695a\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\uff0c\u53cd\u800c\u6bd4\u5168\u5f00\u66f4\u8d39\u6c14\uff1f<\/summary>\n<p>\u56e0\u4e3a\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u5c31\u6709 8 \u5230 10kW\uff0c\u800c\u53ea\u5f00\u4e00\u7ec4\u6696\u6c14\u7247\uff0c\u623f\u5b50\u53ef\u80fd\u53ea\u6d88\u8017 2kW\u3002\u591a\u51fa\u6765\u7684\u70ed\u91cf\u6ca1\u5730\u65b9\u53bb\uff0c\u6c34\u6e29\u5f88\u5feb\u70e7\u5230\u8bbe\u5b9a\u503c\uff0c\u9505\u7089\u7184\u706b\uff1b\u8fc7\u4e00\u4f1a\u513f\u6c34\u6e29\u6389\u4e0b\u6765\uff0c\u53c8\u70b9\u706b\u3002\u6bcf\u6b21\u70b9\u706b\u90fd\u4ece\u6ee1\u529f\u7387\u8d77\u6b65\uff0c\u8fd9\u4e00\u6bb5\u70e7\u6389\u7684\u71c3\u6c14\u767d\u767d\u6d6a\u8d39\u3002\u6240\u4ee5\u4e0d\u662f\u5f00\u5f97\u5c11\u5c31\u7701\uff0c\u662f\u9505\u7089\u7684\u6700\u5c0f\u8f93\u51fa\u548c\u4f60\u5b9e\u9645\u7528\u6389\u7684\u70ed\u91cf\u5dee\u5f97\u8d8a\u8fdc\uff0c\u6d6a\u8d39\u8d8a\u591a\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u6696\u6c14\u7247\u548c\u5730\u6696\u80fd\u5171\u7528\u4e00\u53f0\u58c1\u6302\u7089\u5417\uff1f<\/summary>\n<p>\u53ef\u4ee5\u3002\u540c\u4e00\u53f0\u4e24\u7528\u7089\u65e2\u80fd\u5e26\u5730\u6696\u76d8\u7ba1\uff0c\u4e5f\u80fd\u5e26\u6696\u6c14\u7247\uff0c\u901a\u8fc7\u5206\u96c6\u6c34\u5668\u548c\u6e29\u63a7\u5206\u533a\u5206\u522b\u8c03\u8282\u3002\u8981\u6ce8\u610f\u4e24\u8005\u7684\u8bbe\u8ba1\u6c34\u6e29\u4e0d\u4e00\u6837\uff0c\u5730\u6696\u5b9c\u4f4e\u6e29\u3001\u6696\u6c14\u7247\u9700\u8981\u8f83\u9ad8\u6c34\u6e29\uff0c\u5f97\u5728\u8bbe\u8ba1\u9636\u6bb5\u5c31\u5206\u5f00\u7b97\u5de5\u51b5\uff0c\u5426\u5219\u5bb9\u6613\u51fa\u73b0\u51b7\u70ed\u4e0d\u5747\uff0c\u6216\u8005\u9505\u7089\u9891\u7e41\u542f\u505c\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u96f6\u51b7\u6c34\u70ed\u6c34\u7cfb\u7edf\u503c\u4e0d\u503c\u5f97\u505a\uff1f<\/summary>\n<p>\u66f4\u63a8\u8350\u505a\u4e3b\u7ba1\u70ed\u6c34\u5faa\u73af\uff1a\u5faa\u73af\u53ea\u8d70\u5230\u5206\u96c6\u6c34\u5668\u3001\u652f\u7ba1\u4e0d\u53c2\u4e0e\u5faa\u73af\uff0c\u914d\u5408\u7ba1\u5f84\u5347\u7ea7\uff08\u4e3b\u7ba1 6 \u5206\u5373 DN25\uff0c\u5927\u6237\u578b 1 \u5bf8\u5373 DN32\uff09\u548c\u540c\u7a0b\u5e03\u5c40\uff0c\u540c\u6837\u80fd\u4e24\u4e09\u79d2\u51fa\u70ed\u6c34\uff0c\u5168\u5c4b\u6c34\u6e29\u5747\u8861\uff0c\u80fd\u8017\u66f4\u4f4e\uff0c\u524d\u63d0\u662f\u4e3b\u7ba1\u548c\u70ed\u6c34\u7ba1\u4e00\u5b9a\u505a\u6a61\u5851\u4fdd\u6e29\u3002\u5168\u5c4b\u96f6\u51b7\u6c34\u4e0d\u5efa\u8bae\uff1a\u652f\u7ba1\u57cb\u5899\uff0c\u70ed\u91cf\u88ab\u5899\u4f53\u5438\u8d70\uff0c\u5bb9\u6613\u8fd1\u7aef\u70eb\u3001\u8fdc\u7aef\u51c9\uff1b24 \u5c0f\u65f6\u5faa\u73af\u52a0\u5899\u4f53\u6563\u70ed\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\uff0c\u80fd\u8017\u660e\u663e\u504f\u9ad8\u3002\u8001\u623f\u6539\u9020\u8fd8\u6709\u4e00\u5c42\u98ce\u9669\uff1a\u73b0\u573a\u5e38\u501f\u51b7\u6c34\u7ba1\u5f53\u56de\u6c34\u7ba1\uff0c\u51b7\u70ed\u6c34\u4e00\u65e6\u63a5\u901a\uff0c\u70ed\u6c34\u53ef\u80fd\u5012\u704c\u51c0\u6c34\u5668\uff0cRO \u819c\u4e0d\u8010\u9ad8\u6e29\uff0c\u4e00\u822c\u4e0d\u8d85 35\u2103\u3002<\/p>\n<\/details>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 class=\"wp-block-heading\">\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p class=\"wp-block-paragraph\">\u5730\u6696\u548c\u6696\u6c14\u7247\u8fd9\u4e00\u5757\uff0c\u6700\u540e\u90fd\u8981\u843d\u5230\"\u8fd9\u5957\u7cfb\u7edf\u914d\u4f60\u5bb6\u5408\u4e0d\u5408\u9002\"\u3002\u76d8\u7ba1\u600e\u4e48\u8d70\u3001\u6696\u6c14\u7247\u6302\u54ea\u513f\u3001\u9505\u7089\u914d\u591a\u5927\uff0c\u90fd\u5f97\u770b\u7740\u623f\u5b50\u7b97\uff0c\u7535\u8bdd\u91cc\u8bf4\u4e0d\u6e05\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95e8\u5e97<\/strong><\/td>\n<td><strong>\u5730\u5740<\/strong><\/td>\n<td><strong>\u7535\u8bdd<\/strong><\/td>\n<td><strong>\u5bfc\u822a<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/td>\n<td>\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B \/ A348<\/td>\n<td><a href=\"tel:02886131795\">028-86131795<\/a><\/td>\n<td><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/td>\n<td>\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<\/td>\n<td><a href=\"tel:02865272586\">028-65272586<\/a><\/td>\n<td><a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u4e24\u5bb6\u95e8\u5e97\u90fd\u5728\u6210\u90fd\u5bcc\u68ee\u7f8e\u5bb6\u5c45\uff0c\u53ef\u4ee5\u76f4\u63a5\u5230\u5e97\u770b\u5b9e\u7269\u3001\u770b\u5730\u6696\u76d8\u7ba1\u548c\u6696\u6c14\u7247\u7684\u5b9e\u666f\u505a\u6cd5\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8425\u4e1a\u65f6\u95f4<\/strong>\uff1a\u5468\u4e00\u5230\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u5468\u65e5 10:00\u201319:00\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u9500\u552e\u987e\u95ee<\/strong>\uff1a\u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a>\uff1b\u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u552e\u540e<\/strong>\uff1a\u6768\u6676\u6676 156-8007-5476\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u4ece 2004 \u5e74\u8d77\u505a\u6696\u901a\uff0c\u7d2f\u8ba1\u670d\u52a1 20000 \u6237\u4ee5\u4e0a\u3002\u4f1a\u5458\u5ba2\u6237\u4eab 10 \u5e74\u5305\u4fee\uff1b\u7ba1\u6750\u6574\u6839\u65e0\u63a5\u5934\u7684\u90e8\u5206\u6309\u5382\u5bb6 50 \u5e74\u8d28\u4fdd\u6267\u884c\uff0c\u63a5\u5934\u3001\u7ba1\u9053\u710a\u70b9\u3001\u9600\u95e8\u63a5\u53e3\u548c\u7cfb\u7edf\u8c03\u8bd5\u5c5e\u5de5\u7a0b\u8303\u56f4\u3002\u4f1a\u5458\u6743\u76ca\u7ec6\u5219\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=14071\">\u4f1a\u5458\u6743\u76ca\u8bf4\u660e<\/a>\u3002<\/p>\n<section style=\"margin:28px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0;font-size:15px;line-height:1.8;color:#1a1a1a;\">\u60f3\u7cfb\u7edf\u8bfb\u5b8c\u9f99\u8109\u6696\u901a\u7684\u5168\u90e8\u6280\u672f\u5185\u5bb9\uff1f\u56de\u5230 <a href=\"https:\/\/longmai-nt.com\/?page_id=16039\" style=\"color:#c25a1f;font-weight:700;text-decoration:none;\">\u9f99\u8109\u6696\u901a\u767d\u76ae\u4e66\u4e2d\u5fc3<\/a>\uff0c\u96c6\u4e2d\u83b7\u53d6 17 \u672c\u767d\u76ae\u4e66\u4e0e\u56db\u672c\u6280\u672f\u624b\u518c\u3002<\/p>\n<\/section>\n<section style=\"margin:20px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0 0 10px;font-size:15px;font-weight:700;color:#12314F;\">\u5ef6\u4f38\u9605\u8bfb \u00b7 \u9f99\u8109\u6696\u901a\u6280\u672f\u4f53\u7cfb<\/p>\n<p style=\"margin:0;font-size:14px;line-height:2.2;\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009\uff5c\u6c1f\u673a\u9009\u578b\u3001\u5b89\u88c5\u9a8c\u6536\u4e0e\u552e\u540e\u5168\u89e3<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13098\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13292\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u767d\u76ae\u4e66<\/a>\n<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u7248\u672c\uff1aV2.1 \u7f16\u5236\u65e5\u671f\uff1a2026\u5e7410 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-669","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u88c5\u5730\u6696\u8fd8\u662f\u6696\u6c14\u7247\uff0c\u5148\u770b\u8fd9\u4e00\u518c\u518d\u5b9a\u3002\u5730\u6696\u7ba1\u7528\u591a\u7c97\u3001\u5355\u8def\u80fd\u76d8\u591a\u957f\u3001\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u51e0\u5929\u3001\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\u3001\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\u53cd\u800c\u66f4\u8d39\u6c14\u3001\u96f6\u51b7\u6c34\u503c\u4e0d\u503c\u5f97\u505a\u3002\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u518d\u5230\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u600e\u4e48\u914d\u624d\u4e0d\u6253\u67b6\uff0c\u7ba1\u5f84\u3001\u6c34\u6e29\u3001\u8054\u52a8\u3001\u9a8c\u6536\u7684\u5224\u65ad\u6807\u51c6\u90fd\u5728\u8fd9\u91cc\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=669\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u88c5\u5730\u6696\u8fd8\u662f\u6696\u6c14\u7247\uff0c\u5148\u770b\u8fd9\u4e00\u518c\u518d\u5b9a\u3002\u5730\u6696\u7ba1\u7528\u591a\u7c97\u3001\u5355\u8def\u80fd\u76d8\u591a\u957f\u3001\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u51e0\u5929\u3001\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\u3001\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\u53cd\u800c\u66f4\u8d39\u6c14\u3001\u96f6\u51b7\u6c34\u503c\u4e0d\u503c\u5f97\u505a\u3002\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u518d\u5230\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u600e\u4e48\u914d\u624d\u4e0d\u6253\u67b6\uff0c\u7ba1\u5f84\u3001\u6c34\u6e29\u3001\u8054\u52a8\u3001\u9a8c\u6536\u7684\u5224\u65ad\u6807\u51c6\u90fd\u5728\u8fd9\u91cc\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=669\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T10:06:10+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=669\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=669\",\"name\":\"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-13T09:12:24+00:00\",\"dateModified\":\"2026-11-21T10:06:10+00:00\",\"description\":\"\u6210\u90fd\u88c5\u5730\u6696\u8fd8\u662f\u6696\u6c14\u7247\uff0c\u5148\u770b\u8fd9\u4e00\u518c\u518d\u5b9a\u3002\u5730\u6696\u7ba1\u7528\u591a\u7c97\u3001\u5355\u8def\u80fd\u76d8\u591a\u957f\u3001\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u51e0\u5929\u3001\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\u3001\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\u53cd\u800c\u66f4\u8d39\u6c14\u3001\u96f6\u51b7\u6c34\u503c\u4e0d\u503c\u5f97\u505a\u3002\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u518d\u5230\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u600e\u4e48\u914d\u624d\u4e0d\u6253\u67b6\uff0c\u7ba1\u5f84\u3001\u6c34\u6e29\u3001\u8054\u52a8\u3001\u9a8c\u6536\u7684\u5224\u65ad\u6807\u51c6\u90fd\u5728\u8fd9\u91cc\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=669#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=669\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=669#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u88c5\u5730\u6696\u8fd8\u662f\u6696\u6c14\u7247\uff0c\u5148\u770b\u8fd9\u4e00\u518c\u518d\u5b9a\u3002\u5730\u6696\u7ba1\u7528\u591a\u7c97\u3001\u5355\u8def\u80fd\u76d8\u591a\u957f\u3001\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u51e0\u5929\u3001\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\u3001\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\u53cd\u800c\u66f4\u8d39\u6c14\u3001\u96f6\u51b7\u6c34\u503c\u4e0d\u503c\u5f97\u505a\u3002\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u518d\u5230\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u600e\u4e48\u914d\u624d\u4e0d\u6253\u67b6\uff0c\u7ba1\u5f84\u3001\u6c34\u6e29\u3001\u8054\u52a8\u3001\u9a8c\u6536\u7684\u5224\u65ad\u6807\u51c6\u90fd\u5728\u8fd9\u91cc\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=669","og_locale":"zh_CN","og_type":"article","og_title":"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u88c5\u5730\u6696\u8fd8\u662f\u6696\u6c14\u7247\uff0c\u5148\u770b\u8fd9\u4e00\u518c\u518d\u5b9a\u3002\u5730\u6696\u7ba1\u7528\u591a\u7c97\u3001\u5355\u8def\u80fd\u76d8\u591a\u957f\u3001\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u51e0\u5929\u3001\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\u3001\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\u53cd\u800c\u66f4\u8d39\u6c14\u3001\u96f6\u51b7\u6c34\u503c\u4e0d\u503c\u5f97\u505a\u3002\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u518d\u5230\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u600e\u4e48\u914d\u624d\u4e0d\u6253\u67b6\uff0c\u7ba1\u5f84\u3001\u6c34\u6e29\u3001\u8054\u52a8\u3001\u9a8c\u6536\u7684\u5224\u65ad\u6807\u51c6\u90fd\u5728\u8fd9\u91cc\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=669","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-21T10:06:10+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"10 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=669","url":"https:\/\/longmai-nt.com\/?page_id=669","name":"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-13T09:12:24+00:00","dateModified":"2026-11-21T10:06:10+00:00","description":"\u6210\u90fd\u88c5\u5730\u6696\u8fd8\u662f\u6696\u6c14\u7247\uff0c\u5148\u770b\u8fd9\u4e00\u518c\u518d\u5b9a\u3002\u5730\u6696\u7ba1\u7528\u591a\u7c97\u3001\u5355\u8def\u80fd\u76d8\u591a\u957f\u3001\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u51e0\u5929\u3001\u58c1\u6302\u7089\u9009\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\u3001\u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u53ea\u5f00\u4e00\u7ec4\u53cd\u800c\u66f4\u8d39\u6c14\u3001\u96f6\u51b7\u6c34\u503c\u4e0d\u503c\u5f97\u505a\u3002\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u518d\u5230\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u600e\u4e48\u914d\u624d\u4e0d\u6253\u67b6\uff0c\u7ba1\u5f84\u3001\u6c34\u6e29\u3001\u8054\u52a8\u3001\u9a8c\u6536\u7684\u5224\u65ad\u6807\u51c6\u90fd\u5728\u8fd9\u91cc\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=669#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=669"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=669#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/669","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=669"}],"version-history":[{"count":26,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/669\/revisions"}],"predecessor-version":[{"id":21099,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/669\/revisions\/21099"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=669"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}