{"id":671,"date":"2026-05-13T17:20:19","date_gmt":"2026-05-13T09:20:19","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=671"},"modified":"2026-11-21T18:06:12","modified_gmt":"2026-11-21T10:06:12","slug":"03_%e5%85%a8%e5%8f%98%e9%a2%91%e6%b0%b4%e7%b3%bb%e7%bb%9f%e4%b8%a4%e8%81%94%e4%be%9b-%c2%b7-%e6%8a%80%e6%9c%af%e6%bc%94%e8%bf%9b%e4%b8%8e%e5%ae%9e%e6%88%98%e6%89%8b%e5%86%8c","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=671","title":{"rendered":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c"},"content":{"rendered":"<div class=\"lm-geo\" data-book=\"NT03\" data-cat=\"\u4e24\u8054\u4f9b\" data-layer=\"\u6839\" data-code=\"NT03\" data-step=\"1\" data-elem=\"\" data-q=\"\u4e24\u8054\u4f9b\u5230\u5e95\u503c\u4e0d\u503c\u5f97\u88c5\"><\/div>\n<\/div>\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c<\/strong>\uff1aV2.5<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e7410\u670825\u65e5<\/p>\n<h2 class=\"wp-block-heading\">\u3010\u672c\u7cfb\u5217\u624b\u518c\u8bf4\u660e\u3011<\/h2>\n<p class=\"wp-block-paragraph\">\u672c\u624b\u518c\u4e3a<strong>\u9f99\u8109\u6696\u901a\u6280\u672f\u624b\u518c\u7cfb\u5217\u7b2c 03 \u53f7<\/strong>\uff0c\u5168\u5957\u5171 4 \u518c\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5e8f\u53f7<\/strong><\/td>\n<td><strong>\u540d\u79f0<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>01<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=667\">\u300a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u6c1f\u673a\u539f\u7406\u3001\u4ea7\u54c1\u5bf9\u4f4d\u3001\u538b\u7f29\u673a\u9009\u578b\u3001\u4e09\u7ba1\u5236<\/td>\n<\/tr>\n<tr>\n<td><strong>02<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=669\">\u300a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u71c3\u6c14\u70ed\u6e90\u3001\u5730\u6696\u4e0e\u6696\u6c14\u7247\u672b\u7aef\u3001\u7ba1\u8def\u8bbe\u8ba1\u3001\u6c34\u529b\u5e73\u8861\u3001\u751f\u6d3b\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td><strong>03<\/strong><\/td>\n<td><strong>\u300a\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b\uff08\u672c\u9875\uff09<\/strong><\/td>\n<td>\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\u3001\u4e3b\u673a\u4e0e\u6c34\u6e90\u4fa7\u600e\u4e48\u914d\u3001\u4e09\u8054\u4f9b<\/td>\n<\/tr>\n<tr>\n<td><strong>04<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=673\">\u300a\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u6e29\u6e7f\u6c27\u6d01\u9759\u4e94\u7ef4\u3001\u5168\u5c4b\u5168\u611f 3.0\u3001\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">\u672c\u518c\u7ba1\u4ec0\u4e48\uff0c\u4e0d\u7ba1\u4ec0\u4e48<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u7ba1<\/strong>\uff1a\u4e24\u8054\u4f9b\u8fd9\u4e2a\u54c1\u7c7b\u672c\u8eab\u2014\u2014\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\u3001\u4e3b\u673a\u4e0e\u6c34\u6e90\u4fa7\u600e\u4e48\u914d\u3001\u6c34\u8def\u67b6\u6784\u3001\u4e00\u6b21\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u3001\u7f13\u51b2\u6c34\u7bb1\u3001\u4e09\u8054\u4f9b\u6210\u7acb\u7684\u6761\u4ef6\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u7ba1<\/strong>\uff1a\u5730\u6696\u672b\u7aef\uff08\u76d8\u7ba1\u95f4\u8ddd\u3001\u4e3b\u7ba1\u7ba1\u5f84\u3001\u5206\u96c6\u6c34\u5668\u3001\u6c34\u529b\u5e73\u8861\u3001\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u4e0a\u4e8c\u6b21\u7cfb\u7edf\uff09\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=669\">02 \u53f7\u624b\u518c<\/a>\u3002\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u672c\u4f53\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=667\">01 \u53f7\u624b\u518c<\/a>\u3002\u4e94\u6052\u7684\u6e29\u6e7f\u6c27\u6d01\u9759\u4e0e\u9632\u7ed3\u9732\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=673\">04 \u53f7\u624b\u518c<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5177\u4f53\u5230\u67d0\u4e00\u53f0\u673a\u5668\u7684\u5916\u673a\u5c3a\u5bf8\u3001\u63a5\u7ba1\u53e3\u5f84\u3001\u9010\u9879\u53c2\u6570\uff0c\u672c\u518c\u4e0d\u590d\u8ff0\uff1a\u5929\u6c1f\u5730\u6c34\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u300a\u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u8be6\u60c5\u9875\u300b<\/a>\uff0c\u5929\u6c34\u5730\u6c34\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u300a\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66\u300b<\/a>\u3002\u672c\u518c\u53ea\u7ba1\u9009\u54ea\u4e00\u79cd\u8def\uff0c\u7ba1\u5230\u578b\u53f7\u90a3\u4e00\u5c42\u5c31\u505c\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u5148\u7edf\u4e00\u53eb\u6cd5\uff1a\u4e24\u8054\u4f9b\u3001\u4e8c\u8054\u4f9b<\/h3>\n<p class=\"wp-block-paragraph\">\u5e02\u573a\u4e0a\u8fd8\u5e38\u89c1\u300c<strong>\u4e8c\u8054\u4f9b<\/strong>\u300d\u8fd9\u4e2a\u5199\u6cd5\uff0c\u5b83\u662f\u53e3\u8bed\u4e66\u5199\u53d8\u4f53\uff0c\u8ddf\u672c\u9875\u8bf4\u7684 <strong>\u4e24\u8054\u4f9b\uff08\u7a7a\u8c03\uff0b\u5730\u6696\u4e24\u8054\u4f9b\uff09<\/strong>\u6307\u7684\u662f\u540c\u4e00\u5957\u7cfb\u7edf\u3002\u6b63\u5f0f\u6280\u672f\u6587\u6863\u3001\u884c\u4e1a\u89c4\u7a0b\u548c\u5382\u5bb6\u578b\u53f7\u518c\u7edf\u4e00\u7528\u300c\u4e24\u8054\u4f9b\u300d\u3002\u641c\u300c\u4e8c\u8054\u4f9b\u300d\u8fdb\u6765\u7684\u8bfb\u8005\uff0c\u770b\u5230\u7684\u6b63\u662f\u8fd9\u4e00\u9875\u8bb2\u7684\u5185\u5bb9\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u53e6\u4e00\u79cd\u8bf4\u6cd5\u53eb\u300c<strong>\u6c34\u673a\u4e24\u8054\u4f9b<\/strong>\u300d\uff0c\u4e13\u6307\u672c\u518c\u7684\u5929\u6c34\u5730\u6c34\u90a3\u4e00\u652f\u2014\u2014\u4e3b\u673a\u8d70\u6c34\u3001\u672b\u7aef\u4e5f\u8d70\u6c34\u3002\u5929\u6c1f\u5730\u6c34\u867d\u7136\u5730\u4e0a\u4e5f\u8d70\u6c34\uff0c\u4f46\u5929\u4e0a\u8d70\u7684\u662f\u6c1f\uff0c\u6240\u4ee5\u4e00\u822c\u4e0d\u8fd9\u4e48\u53eb\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u4e3a\u4ec0\u4e48\u4e24\u8054\u4f9b\u8981\u6709\u5355\u72ec\u4e00\u518c<\/h3>\n<p class=\"wp-block-paragraph\">\u56e0\u4e3a\u300c\u4e24\u8054\u4f9b\u300d\u8fd9\u4e2a\u8bcd\u4e89\u7684\uff0c\u662f\u70ed\u6e90\u4e4b\u540e\u90a3\u4e00\u6bb5\u8def\u600e\u4e48\u8d70\u300201 \u53f7\u624b\u518c\u8bb2\u5230\u6c34\u6a21\u5757\u4e3a\u6b62\uff1b\u6c34\u6a21\u5757\u5f80\u540e\u7684\u5730\u6696\u505a\u6cd5\uff0c\u5f52 02 \u53f7\u624b\u518c\uff1b\u800c\u8fd9\u56db\u53f0\u673a\u5668\u5404\u81ea\u9002\u5408\u8c01\u5bb6\uff0c\u662f\u672c\u518c\u7684\u4e8b\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e00\u53f0\u70ed\u6cf5\u4e3b\u673a\u53ea\u505a\u4e00\u4ef6\u4e8b\uff1a\u628a\u5ba4\u5916\u7684\u70ed\u91cf\u642c\u8fdb\u5c4b\u91cc\u3002\u642c\u8fdb\u6765\u4e4b\u540e\u5f80\u54ea\u513f\u9001\uff0c\u624d\u6709\u533a\u522b\u2014\u2014\u76f4\u63a5\u9001\u8fdb\u7a7a\u6c14\uff0c\u662f\u591a\u8054\u673a\uff1b\u7ecf\u8fc7\u4e00\u4e2a\u6c1f\u6c34\u6362\u70ed\u5668\u9001\u7ed9\u5730\u6696\u7684\u6c34\uff0c\u662f\u5929\u6c1f\u5730\u6c34\uff1b\u4e3b\u673a\u6362\u70ed\u5668\u76f4\u63a5\u5bf9\u6c34\uff0c\u7a7a\u8c03\u548c\u5730\u6696\u90fd\u8d70\u6c34\uff0c\u662f\u5929\u6c34\u5730\u6c34\uff1b\u70ed\u9001\u53bb\u52a0\u70ed\u751f\u6d3b\u70ed\u6c34\u7bb1\uff0c\u662f\u5929\u6c1f\u70ed\u6c34\u3002\u540c\u4e00\u4e2a\u6839\uff0c\u56db\u79cd\u8d70\u6cd5\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u4e24\u8054\u4f9b\u7684\u56db\u79cd\u914d\u6cd5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u914d\u6cd5<\/strong><\/td>\n<td><strong>\u5916\u673a<\/strong><\/td>\n<td><strong>\u6c34\u6a21\u5757<\/strong><\/td>\n<td><strong>\u5ba4\u5185\u673a<\/strong><\/td>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><strong>\u9002\u5408\u8c01<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u667a\u4eab AQ<\/strong><br \/>\u4e00\u4f53\u673a<\/td>\n<td>RAS-80~160FSPUNAQ<br \/>\u5355\u76f8 220V\uff0c80 \/ 100 \/ 125 \/ 140 \/ 160 \u4e94\u6863<\/td>\n<td>\u5185\u7f6e\u5728\u5916\u673a\u91cc\uff0c\u4e0d\u53e6\u9009\u6c34\u6a21\u5757<\/td>\n<td>\u901a\u7528\u5185\u673a<\/td>\n<td>\u5e26\uff0c\u70ed\u56de\u6536<\/td>\n<td>90~160\u33a1\uff0c\u5916\u673a\u4f4d\u7d27\u5f20\uff0c\u7a7a\u8c03\u5730\u6696\u70ed\u6c34\u4e00\u673a\u89e3\u51b3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u667a\u4eab NQ<\/strong><br \/>\u4e00\u4f53\u673a<\/td>\n<td>RAS-100~200FSPUNQ\uff08\u5355\u76f8 220V\uff0c\u516d\u6863\uff09<br \/>RAS-224\/240\/280\/320FSPUNYQ\uff08\u4e09\u76f8 380V\uff0c\u56db\u6863\uff09<\/td>\n<td>\u5185\u7f6e\u5728\u5916\u673a\u91cc\uff0c\u4e0d\u53e6\u9009\u6c34\u6a21\u5757<\/td>\n<td>\u901a\u7528\u5185\u673a<\/td>\n<td>\u4e0d\u5e26\uff0c\u53e6\u914d\u70ed\u6c34\u5668<\/td>\n<td>100~320\u33a1\uff0c\u51b7\u91cf\u8981\u5927\uff0c\u5ba4\u5185\u673a\u53f0\u6570\u591a<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5c0a\u777f\u5168\u6548\u2161<\/strong><br \/>\u5206\u4f53\u673a<\/td>\n<td>RAS-125~335FSXPN5Q\/Y5Q<br \/>125 \/ 140 \/ 160 \/ 180 \/ 200 \/ 224<br \/>252 \/ 280 \/ 300 \/ 335<br \/>\u5171\u5341\u6863<\/td>\n<td>\u5916\u7f6e\uff0cRWMG-160 \/ 224 \/ 280 \/ 335 \u5168\u6548\u6c34\u6a21\u5757\uff0c\u914d PC-WMH3Q \u63a7\u5236\u5668<\/td>\n<td>\u4e09\u7ba1\u5236 FSVN2QB\/PC<\/td>\n<td>\u53ef\u914d\u70ed\u6c34\u7bb1\u6210\u4e09\u8054\u4f9b<\/td>\n<td>\u8981\u9664\u6e7f\u4e0d\u964d\u6e29\u3001\u6e29\u6e7f\u5206\u5f00\u63a7\uff1b\u5927\u5e73\u5c42\u3001\u5730\u4e0b\u5ba4\u3001\u6015\u6f6e<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5c0a\u777f\u522b\u5885<\/strong><br \/>\u5206\u4f53\u673a<\/td>\n<td>RAS-504 \/ 560FSPNYZQA<\/td>\n<td>\u5916\u7f6e\uff0cRWMG-160 \/ 200 \/ 280 \/ 335 \u4e24\u7ba1\u5236\u6c34\u6a21\u5757\uff0c\u53ef\u63a5 2~3 \u53f0\uff0c\u914d PC-WMH2Q \u63a7\u5236\u5668<\/td>\n<td>\u4e24\u7ba1\u5236\u5185\u673a<\/td>\n<td>\u6309\u9700<\/td>\n<td>300\u33a1\u4ee5\u4e0a\u72ec\u680b\uff0c\u5c42\u6570\u591a\u3001\u7ba1\u8def\u957f\u3001\u672b\u7aef\u591a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><em>\u6c34\u6a21\u5757\u5206\u4e24\u6761\u7ebf\uff0c\u4e0d\u80fd\u4e92\u6362\uff1a\u5168\u6548\u4e13\u7528\u7ebf\uff08160 \/ 224 \/ 280 \/ 335\uff0c\u914d\u4e09\u7ba1\u5236\u5185\u673a\uff09\u4e0e\u4e24\u7ba1\u5236\u7ebf\uff08160 \/ 200 \/ 280 \/ 335\uff0c\u914d\u522b\u5885\u4e0e mini \u2161 \u7cfb\u5217\uff09\u3002\u4e24\u6761\u7ebf\u578b\u53f7\u53ea\u5dee\u4e00\u4e2a\u5b57\u6bcd\uff0c\u914d\u7f6e\u524d\u5fc5\u987b\u628a\u5916\u673a\u578b\u53f7\u548c\u6c34\u6a21\u5757\u578b\u53f7\u5e76\u6392\u6838\u5bf9\u4e00\u6b21\u3002<\/em><\/p>\n<h4 class=\"wp-block-heading\">\u56db\u8def\u4e0d\u662f\u6309\u4ea7\u54c1\u7ebf\u5206\u7684<\/h4>\n<p class=\"wp-block-paragraph\">\u56db\u79cd\u914d\u6cd5\u4e0d\u662f\u628a\u4ea7\u54c1\u76ee\u5f55\u6284\u4e00\u904d\uff0c\u662f\u6309\u4e09\u4ef6\u4e8b\u5206\u7684\uff1a\u6c34\u6a21\u5757\u5728\u4e0d\u5728\u673a\u5668\u91cc\u3001\u6709\u6ca1\u6709\u751f\u6d3b\u70ed\u6c34\u3001\u5ba4\u5185\u673a\u5e26\u4e0d\u5e26\u4e09\u6839\u7ba1\u3002\u6240\u4ee5\u5ba2\u6237\u95ee\u300c\u6211\u5bb6\u8be5\u88c5\u54ea\u4e00\u79cd\u300d\uff0c\u95ee\u7684\u5176\u5b9e\u662f\u300c\u4f60\u5bb6\u8981\u4e0d\u8981\u751f\u6d3b\u70ed\u6c34\u3001\u9762\u79ef\u591a\u5927\u3001\u8981\u4e0d\u8981\u6e29\u6e7f\u5206\u5f00\u63a7\u300d\u3002<\/p>\n<h4 class=\"wp-block-heading\">\u4e00\u773c\u5206\u56db\u8def\uff0c\u770b\u4e09\u4e2a\u5730\u65b9<\/h4>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e00\u770b\u5ba4\u5185\u673a\u662f\u4e0d\u662f\u4e09\u6839\u7ba1\u3002<\/strong>\u53ea\u6709\u5168\u6548\u80fd\u914d\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\uff0c\u522b\u5885\u4e5f\u914d\u4e0d\u4e86\u3002\u5e26\u4e09\u6839\u7ba1\u7684\u4e00\u5b9a\u662f\u5168\u6548\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e8c\u770b\u6709\u6ca1\u6709\u751f\u6d3b\u70ed\u6c34\u3002<\/strong>AQ \u5e26\uff0cNQ \u4e0d\u5e26\u2014\u2014\u8fd9\u4e24\u8def\u90fd\u662f\u667a\u4eab\uff0c\u6c34\u6a21\u5757\u90fd\u88c5\u5728\u5916\u673a\u809a\u5b50\u91cc\uff0c\u5916\u89c2\u4e0a\u5206\u4e0d\u51fa\u6765\uff0c\u5dee\u522b\u5c31\u5728\u70ed\u6c34\u8fd9\u4e00\u9879\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e09\u770b\u6c34\u6a21\u5757\u5728\u4e0d\u5728\u673a\u5668\u91cc\u3002<\/strong>\u667a\u4eab AQ \u548c NQ \u7684\u6c34\u6a21\u5757\u5185\u7f6e\uff0c\u88c5\u597d\u5c31\u80fd\u51fa\u51b7\u70ed\u6c34\uff1b\u5168\u6548\u548c\u522b\u5885\u7684\u6c34\u6a21\u5757\u662f\u5355\u72ec\u4e00\u53f0\uff0c\u8981\u53e6\u5360\u4e00\u4e2a\u8bbe\u5907\u4f4d\u3001\u53e6\u63a5\u7ebf\u63a7\u5668\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e09\u53e5\u8bdd\u8bf4\u5b8c\uff1aAQ \u662f\u4e00\u673a\u4e09\u7528\uff0cNQ \u662f\u53ea\u8981\u51b7\u6696\u4f46\u8981\u5927\u51b7\u91cf\uff0c\u5168\u6548\u662f\u8981\u6e29\u6e7f\u5206\u5f00\u63a7\uff0c\u522b\u5885\u662f\u9762\u79ef\u5927\u5230\u53ea\u80fd\u7528\u5927\u673a\u5668\u3002\u5927\u51b7\u91cf\u90a3\u4e00\u6bb5\u8981\u4e09\u76f8\u7535\uff0c\u88c5\u4fee\u524d\u5f97\u5148\u786e\u8ba4\u5165\u6237\u7535\u8868\u3002<\/p>\n<h4 class=\"wp-block-heading\">\u5168\u6548\u4e3a\u4ec0\u4e48\u662f\u91cd\u70b9<\/h4>\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u4ea7\u54c1\u534f\u8bae\u51b3\u5b9a\u7684\uff0c\u4e0d\u662f\u6211\u4eec\u6311\u7684\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5ba2\u6237\u8981\u7684\u662f\u300c\u9664\u6e7f\u4e0d\u964d\u6e29\u3001\u6e29\u6e7f\u5206\u5f00\u63a7\u300d\u3002\u80fd\u540c\u65f6\u505a\u5230\u8fd9\u4e24\u70b9\u7684\u53ea\u6709\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\uff1b\u800c\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u53ea\u80fd\u914d\u5168\u6548\u5916\u673a\u2014\u2014\u522b\u5885\u3001NQ\u3001AQ \u90fd\u914d\u4e0d\u4e86\uff0c\u8fd9\u662f\u5382\u65b9\u7684\u786c\u89c4\u5219\uff0c\u4e0d\u662f\u642d\u914d\u5efa\u8bae\u3002\u6240\u4ee5\u5929\u6c1f\u5730\u6c34\u91cc\u60f3\u5b9e\u73b0\u6e29\u6e7f\u53cc\u63a7\uff0c\u53ea\u5269\u5168\u6548\u8fd9\u4e00\u6761\u8def\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u8fd9\u4e5f\u89e3\u91ca\u4e86\u4e00\u4e2a\u73b0\u8c61\uff1a\u5ba2\u6237\u62ff\u7740\u51e0\u5bb6\u65b9\u6848\u6765\u6bd4\uff0c\u6bd4\u7684\u4e0d\u662f\u8c01\u5bb6\u4fbf\u5b9c\uff0c\u800c\u662f\u6885\u96e8\u5b63\u3001\u56de\u5357\u5929\u90a3\u4e24\u4e2a\u6708\uff0c\u5c4b\u91cc\u80fd\u4e0d\u80fd\u4e0d\u9760\u964d\u6e29\u628a\u6e7f\u5ea6\u538b\u4e0b\u53bb\u3002\u8fd9\u4e2a\u95ee\u9898\u7b54\u6848\u53ea\u6709\u4e00\u4e2a\u3002<\/p>\n<h4 class=\"wp-block-heading\">\u4e09\u8054\u4f9b\u4e0d\u662f\u7b2c\u4e94\u79cd\u914d\u6cd5<\/h4>\n<p class=\"wp-block-paragraph\">\u4e09\u8054\u4f9b\u662f\u5168\u6548\u7684\u4e00\u79cd\u52a0\u6cd5\uff1a\u5168\u6548\u5916\u673a + \u6c34\u6a21\u5757 + \u70ed\u6c34\u7bb1\uff0c\u7a7a\u8c03\u3001\u5730\u6696\u3001\u751f\u6d3b\u70ed\u6c34\u4e09\u6837\u4e00\u8d77\u4f9b\u3002\u591a\u4e00\u4e2a\u6c34\u7bb1\uff0c\u4e0d\u662f\u591a\u4e00\u53f0\u4e3b\u673a\u3002\u6240\u4ee5\u672c\u518c\u8bb2\u56db\u8def\uff0c\u4e0d\u63d0\u7b2c\u4e94\u8def\u2014\u2014\u5b83\u662f\u7b2c\u4e09\u8def\u7684\u52a0\u9009\u9879\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u600e\u4e48\u8bfb\u8fd9\u56db\u518c<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9605\u8bfb\u8def\u5f84\u5efa\u8bae<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20779\">\u4e24\u8054\u4f9b\u5e38\u89c1\u8bef\u533a\uff1a\u6c34\u7bb1\u3001\u53cc\u673a\u3001\u6c34\u6da6\u8212\u9002\u8fd9\u4e9b\u8bf4\u6cd5\u9519\u5728\u54ea<\/a> \u2014\u2014 \u6c34\u7bb1\u3001\u53cc\u673a\u3001\u8212\u9002\u5ea6\u7b49\u8bf4\u6cd5\u9010\u6761\u8fa8\u6790<\/li>\n<li><strong>\u53ea\u60f3\u77e5\u9053\u6211\u5bb6\u88c5\u54ea\u79cd\u4e24\u8054\u4f9b<\/strong>\uff1a\u770b\u5b8c\u672c\u9875\u7684\u56db\u79cd\u914d\u6cd5\uff0c\u518d\u6309\u9762\u79ef\u53bb 1957\uff08\u5929\u6c1f\u5730\u6c34\uff09\u6216 13098\uff08\u5929\u6c34\u5730\u6c34\uff09\u67e5\u5177\u4f53\u578b\u53f7<\/li>\n<li><strong>\u65b0\u624b\u5165\u95e8<\/strong>\uff1a01\u219202\u219203\u219204\uff08\u6309\u6280\u672f\u96be\u5ea6\u9012\u8fdb\uff09<\/li>\n<li><strong>\u53ea\u5173\u5fc3\u5730\u6696<\/strong>\uff1a\u76f4\u63a5\u53bb 02 \u53f7\u624b\u518c\uff1b\u672c\u518c\u8bb2\u7684\u662f\u4e3b\u673a\u90a3\u4e00\u7aef\uff0c\u5730\u6696\u600e\u4e48\u94fa\u4e0d\u5728\u8fd9\u91cc<\/li>\n<li><strong>\u9ad8\u7aef\u65b9\u6848<\/strong>\uff1a\u672c\u518c + 04 \u53f7\u624b\u518c\uff08\u4ece\u4e24\u8054\u4f9b\u5230\u4e94\u6052\uff09<\/li>\n<li><strong>\u505a\u522b\u5885\u5927\u5b85<\/strong>\uff1a\u672c\u518c\u7684\u7b2c\u56db\u8def + 02 \u53f7\u624b\u518c\u7684\u6c34\u529b\u5e73\u8861\u90a3\u4e00\u7ae0<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u53c9\u5f15\u7528\u89c4\u5219<\/strong>\uff1a\u672c\u624b\u518c\u4e2d\u5f15\u7528\u5176\u4ed6\u624b\u518c\u5185\u5bb9\u65f6\uff0c\u4ee5\u5e8f\u53f7\u6807\u6ce8\uff08\u5982\u300c\u8be6\u89c1 02 \u53f7\u624b\u518c\u7b2c 2.1 \u8282\u300d\uff09\uff0c\u88ab\u5f15\u7528\u7684\u624b\u518c\u540d\u79f0\u90fd\u53ef\u4ee5\u70b9\u5f00\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u90e8\u5206<\/strong><\/td>\n<td><strong>\u6807\u9898<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e00\u90e8\u5206<\/strong><\/td>\n<td>\u6280\u672f\u6f14\u8fdb\u4e0e\u54c1\u724c\u771f\u76f8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e8c\u90e8\u5206<\/strong><\/td>\n<td>\u4e24\u8054\u4f9b\u4e24\u6761\u8def\u2014\u2014\u5929\u6c1f\u5730\u6c34\u4e0e\u5929\u6c34\u5730\u6c34<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e09\u90e8\u5206<\/strong><\/td>\n<td>\u6c34\u7cfb\u7edf\u7684\u4e3b\u673a\u81ea\u7531\u2014\u2014\u70ed\u6e90\u4e0e\u672b\u7aef\u4e3a\u4ec0\u4e48\u80fd\u62c6\u5f00\u914d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u56db\u90e8\u5206<\/strong><\/td>\n<td>\u7cfb\u7edf\u67b6\u6784\u6df1\u5ea6\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e94\u90e8\u5206<\/strong><\/td>\n<td>\u5e38\u89c1\u6545\u969c\u4e0e\u5e02\u573a\u4e71\u8c61<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u516d\u90e8\u5206<\/strong><\/td>\n<td>\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u6307\u5357<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e03\u90e8\u5206<\/strong><\/td>\n<td>\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u672c\u5206\u6790<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u516b\u90e8\u5206<\/strong><\/td>\n<td>\u5b9e\u6218\u65b9\u6848\u4e0e\u6c9f\u901a\u8bdd\u672f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e5d\u90e8\u5206<\/strong><\/td>\n<td>\u522b\u5885\u4e13\u6848\u4e66\uff08\u5b9e\u6218\u6848\u4f8b\uff09<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u5341\u90e8\u5206<\/strong><\/td>\n<td>\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u5341\u4e00\u90e8\u5206<\/strong><\/td>\n<td>\u5ba2\u6237\u5e38\u89c1\u8d28\u7591\u300c\u5c0f\u9a6c\u62c9\u5927\u8f66\u300d\u5b8c\u6574\u5e94\u5bf9<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9644\u5f55<\/strong><\/td>\n<td>\u5173\u952e\u6570\u636e\u3001\u516c\u5f0f\u4e0e\u6838\u67e5\u6807\u8bb0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e00\u90e8\u5206\uff1a\u6280\u672f\u6f14\u8fdb\u4e0e\u54c1\u724c\u771f\u76f8<\/h2>\n<h3 class=\"wp-block-heading\">1.1 \u6838\u5fc3\u54c1\u724c\u4e0e\u672f\u8bed\u5b9a\u4e49<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u54c1\u724c\/\u672f\u8bed<\/strong><\/td>\n<td><strong>\u5b9a\u4e49<\/strong><\/td>\n<td><strong>\u5907\u6ce8<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u65e5\u7acb (HITACHI)<\/strong><\/td>\n<td>\u65e5\u7cfb\u5168\u53d8\u9891\u6280\u672f\u4ee3\u8868\uff0c\u6838\u5fc3\u538b\u7f29\u673a\u53ca\u63a7\u5236\u6280\u672f\u63d0\u4f9b\u8005<\/td>\n<td>\u6c34\u5885\u9002\u7cfb\u5217\u3001\u5f3a\u70edD\u7cfb\u5217<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ea6\u514b (YORK)<\/strong><\/td>\n<td>\u7f8e\u7cfb\u56db\u5927\u54c1\u724c\u4e4b\u4e00<\/td>\n<td>YVAG\u4e3a\u5929\u6c34\u5730\u6c34\u4ee3\u8868<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5f00\u5229 (Carrier)<\/strong><\/td>\n<td>\u7f8e\u7cfb\u56db\u5927\u54c1\u724c\u4e4b\u4e00<\/td>\n<td>1902\u5e74\u53d1\u660e\u73b0\u4ee3\u79d1\u5b66\u7a7a\u8c03<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7279\u7075 (Trane)<\/strong><\/td>\n<td>\u7f8e\u7cfb\u56db\u5927\u54c1\u724c\u4e4b\u4e00<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e24\u8054\u4f9b<\/strong><\/td>\n<td>\u4e00\u5957\u4e3b\u673a\u7cfb\u7edf\u540c\u65f6\u6ee1\u8db3\u7a7a\u8c03\u5236\u51b7\u4e0e\u5730\u6696\u5236\u70ed<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u6c34\u5730\u6c34<\/strong><\/td>\n<td>\u7a7a\u8c03\u5236\u51b7\u8d70\u51b7\u6c34\uff0c\u5730\u6696\u5236\u70ed\u8d70\u70ed\u6c34<\/td>\n<td>\u5168\u6c34\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5168\u53d8\u9891<\/strong><\/td>\n<td>\u538b\u7f29\u673a\u3001\u6c34\u6cf5\u3001\u98ce\u673a\u5747\u91c7\u7528\u53d8\u9891\u6280\u672f<\/td>\n<td>\u672c\u624b\u518c\u6838\u5fc3\u8bba\u8ff0\u5bf9\u8c61<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">1.2 \u6280\u672f\u6f14\u8fdb\uff1a\u4ece\u5927\u578b\u6c34\u673a\u5230\u5bb6\u7528\u5168\u53d8\u9891<\/h3>\n<p class=\"wp-block-paragraph\"><strong>1.2.1 \u7f8e\u7cfb\u54c1\u724c\u7684\u8d77\u6e90\uff08\u5927\u578b\u5546\u7528\u6c34\u673a\uff09<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u5f00\u5229\u535a\u58eb\u4e8e1902\u5e74\u53d1\u660e\u73b0\u4ee3\u79d1\u5b66\u7a7a\u8c03\u7cfb\u7edf<\/li>\n<li>\u7f8e\u7cfb\u54c1\u724c\u6838\u5fc3\u4f18\u52bf\u5728\u4e8e<strong>\u5927\u578b\u5546\u7528\u673a\u7ec4<\/strong>\uff08\u87ba\u6746\u673a\u3001\u79bb\u5fc3\u673a\uff09\uff0c\u4ee5<strong>\u6c34\u4f5c\u4e3a\u51b7\u5a92<\/strong>\u8fdb\u884c\u6362\u70ed<\/li>\n<li>\u65e9\u671f\u8fdb\u5165\u5bb6\u7528\u9886\u57df\u65f6\u91c7\u7528<strong>\u5b9a\u9891\u538b\u7f29\u673a<\/strong>\uff08\u8c37\u8f6e\u6da1\u65cb\uff0c\u540e\u88ab\u827e\u9ed8\u751f\u6536\u8d2d\uff09\uff0c\u201c\u6570\u7801\u6da1\u65cb\u201d\u5b9e\u4e3a\u6863\u4f4d\u8c03\u8282\u7684\u5b9a\u9891\u673a\u7ec4<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5546\u7528\u4e0e\u5bb6\u7528\u7684\u6839\u672c\u77db\u76fe<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u5546\u7528\u573a\u666f<\/strong>\uff1a\u529e\u516c\u5ba4\u3001\u5546\u94fa\u2014\u2014\u4e0a\u73ed\u5168\u5f00\uff0c\u4e0b\u73ed\u5168\u5173<\/li>\n<li><strong>\u5bb6\u7528\u573a\u666f<\/strong>\uff1a\u522b\u5885\u3001\u5927\u5e73\u5c42\u2014\u2014\u767d\u5929\u5f00\u5ba2\u9910\u5385\uff0c\u665a\u4e0a\u5f00\u5367\u5ba4<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">\u5b9a\u9891\u673a\u7ec4\u548c\u5b9a\u9891\u6c34\u6cf5\u5728\u5bb6\u7528\u90e8\u5206\u8d1f\u8377\u4e0b\uff0c\u9020\u6210<strong>\u6781\u5927\u7684\u80fd\u8017\u548c\u6d41\u91cf\u6ce2\u52a8<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>1.2.2 \u65e5\u7cfb\u54c1\u724c\u7684\u5d1b\u8d77\uff08\u5bb6\u7528\u6c1f\u673a\u53d8\u9891\u6280\u672f\uff09<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u65e5\u672c\u4f01\u4e1a\u53d1\u5c55\u4e86<strong>\u70ed\u6cf5\u538b\u7f29\u673a\u6280\u672f<\/strong>\u548c<strong>\u51b7\u5a92\u6280\u672f<\/strong><\/li>\n<li>\u4ea7\u54c1\u5f62\u6001\uff1a\u7a97\u673a \u2192 \u4e00\u4f53\u673a \u2192 \u4e00\u62d6\u4e00\u5355\u5143\u673a \u2192 <strong>\u5bb6\u7528\u591a\u8054\u673a<\/strong><\/li>\n<li>\u4e3b\u8981\u538b\u7f29\u673a\u6280\u672f\u63d0\u4f9b\u8005\uff1a\u65e5\u7acb\u3001\u5927\u91d1\u3001\u4e09\u83f1\u7535\u673a\u3001\u4e09\u83f1\u91cd\u5de5\u3001\u677e\u4e0b\u3001\u4e1c\u829d<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>1.2.3 \u4e24\u8054\u4f9b\u65f6\u4ee3\u7684\u5230\u6765<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u5728\u539f\u6709\u6c1f\u7cfb\u7edf\u5916\u673a\u57fa\u7840\u4e0a\uff0c\u589e\u52a0<strong>\u6c34\u6a21\u5757\uff08\u677f\u5f0f\u6362\u70ed\u5668\uff09<\/strong>\uff0c\u5b9e\u73b0\u51b7\u5a92\u4e0e\u6c34\u7684\u70ed\u4ea4\u6362\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e09\u79cd\u7cfb\u7edf\u5f62\u6001<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u5236\u51b7\u65b9\u5f0f<\/strong><\/td>\n<td><strong>\u5236\u70ed\u65b9\u5f0f<\/strong><\/td>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><strong>\u522b\u79f0<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u6c34\u5730\u6c34<\/strong><\/td>\n<td>\u51b7\u6c34\u8fdb\u98ce\u76d8<\/td>\n<td>\u70ed\u6c34\u8fdb\u5730\u6696<\/td>\n<td>\u53ef\u9009<\/td>\n<td>\u6c34\u673a\u4e24\u8054\u4f9b<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u6c1f\u5730\u6c34<\/strong><\/td>\n<td>\u6c1f\u5229\u6602\u8fdb\u5185\u673a<\/td>\n<td>\u70ed\u6c34\u8fdb\u5730\u6696<\/td>\n<td>\u65e0<\/td>\n<td>\u6c1f\u673a\u4e24\u8054\u4f9b<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u6c1f\u70ed\u6c34<\/strong><\/td>\n<td>\u6c1f\u5229\u6602\u8fdb\u5185\u673a<\/td>\n<td>\u70ed\u6c34\u8fdb\u5730\u6696<\/td>\n<td>\u70ed\u6c34\u8fdb\u6362\u70ed\u6c34\u7bb1<\/td>\n<td>\u4e09\u8054\u4f9b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u65e5\u7acb\u5173\u952e\u65f6\u95f4\u8282\u70b9<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u7ea62015\u5e74<\/strong>\uff1a\u63a8\u51fa\u201c\u5f3a\u70edD\u201d\u7cfb\u5217\u52a0\u6c34\u6a21\u5757\uff0c\u8fdb\u5165\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u9886\u57df<\/li>\n<li><strong>2023\u5e743\u67081\u65e5<\/strong>\uff1a\u53d1\u5e03\u6c34\u5885\u9002VF\u5168\u53d8\u9891\u7cfb\u5217<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">1.3 \u54c1\u724c\u6280\u672f\u771f\u76f8\uff1a\u7f8e\u7cfb\u54c1\u724c\u7684\u201c\u65e5\u7cfb\u5185\u6838\u201d<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u54c1\u724c<\/strong><\/td>\n<td><strong>\u538b\u7f29\u673a\u6765\u6e90<\/strong><\/td>\n<td><strong>\u5907\u6ce8<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ea6\u514b<\/strong><\/td>\n<td>\u591a\u91c7\u7528\u65e5\u7acb\/\u6d77\u7acb\u538b\u7f29\u673a<\/td>\n<td>\u6bcd\u516c\u53f8\u6c5f\u68ee\u81ea\u63a7\u66fe\u6301\u65e5\u7acb\u7a7a\u8c0360%\u80a1\u6743<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5f00\u5229<\/strong><\/td>\n<td>\u90e8\u5206\u673a\u578b\u91c7\u7528\u4e09\u83f1\u7535\u673a\u538b\u7f29\u673a<\/td>\n<td>\u5bb6\u7528MiniVWV\u7cfb\u5217<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7279\u7075<\/strong><\/td>\n<td>\u90e8\u5206\u673a\u578b\u91c7\u7528\u4e09\u83f1\u7535\u673a\u538b\u7f29\u673a<\/td>\n<td>\u884c\u4e1a\u8bf4\u6cd5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u5f20\u8868\u8bf4\u7684\u662f\u56fd\u5185\u6d41\u901a\u7684\u5bb6\u7528\u5c0f\u578b\u6c34\u51b7\u591a\u8054\u673a\uff08mini VWV \u8fd9\u4e00\u7c7b\u6237\u5f0f\u6c34\u673a\u673a\u578b\uff09\uff0c\u4e0d\u4ee3\u8868\u5404\u54c1\u724c\u7684\u5168\u7ebf\u4ea7\u54c1\u3002<\/strong>\u7ea6\u514b\u3001\u5f00\u5229\u3001\u7279\u7075\u5728\u5546\u7528\u5927\u673a\u7ec4\u3001\u79bb\u5fc3\u673a\u3001\u87ba\u6746\u673a\u4e0a\u7684\u538b\u7f29\u673a\u914d\u7f6e\u8ddf\u5bb6\u7528\u673a\u578b\u662f\u4e24\u56de\u4e8b\uff0c\u6709\u4e9b\u578b\u53f7\u7528\u81ea\u4ea7\u538b\u7f29\u673a\uff0c\u6709\u4e9b\u662f\u5916\u8d2d\uff0c\u4e0d\u80fd\u62ff\u8fd9\u4e00\u884c\u53bb\u6982\u62ec\u4e00\u4e2a\u54c1\u724c\u3002\u5bb6\u7528\u673a\u578b\u4e4b\u6240\u4ee5\u5e38\u51fa\u73b0\u65e5\u7cfb\u538b\u7f29\u673a\uff0c\u662f\u56e0\u4e3a\u56fd\u5185\u5bb6\u7528\u53d8\u9891\u538b\u7f29\u673a\u7684\u4f9b\u5e94\u96c6\u4e2d\u5ea6\u9ad8\uff0c\u5c5e\u4e8e\u4f9b\u5e94\u683c\u5c40\u95ee\u9898\uff0c\u4e0d\u6784\u6210\u5bf9\u4efb\u4f55\u54c1\u724c\u7684\u8bc4\u4ef7\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5236\u9020\u4f18\u52bf\uff1a\u65e5\u7cfb\u5185\u673a\u5c01\u88c5\u6280\u672f<\/strong>\u65e5\u7acb\u7b49\u65e5\u7cfb\u54c1\u724c\u7684\u6c1f\u7cfb\u7edf\u5185\u673a\u4e0e\u6c34\u7cfb\u7edf\u98ce\u76d8\u53ef\u5728<strong>\u540c\u4e00\u6761\u751f\u4ea7\u7ebf<\/strong>\u4e0a\u5236\u9020\uff0c\u4ec5\u9700\u66f4\u6362\u6362\u70ed\u5668\u7c7b\u578b\uff0c\u5176\u4f59\u90e8\u4ef6\u5b8c\u5168\u590d\u7528\uff0c\u4f7f\u6c34\u673a\u98ce\u76d8\u65e0\u7f1d\u7ee7\u627f\u6c1f\u673a\u5185\u673a\u7684\u9759\u97f3\u3001\u8282\u80fd\u3001\u51c0\u5316\u3001\u667a\u80fd\u5316\u6280\u672f\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e8c\u90e8\u5206\uff1a\u4e24\u8054\u4f9b\u4e24\u6761\u8def\u2014\u2014\u5929\u6c1f\u5730\u6c34\u4e0e\u5929\u6c34\u5730\u6c34<\/h2>\n<h3 class=\"wp-block-heading\">2.1 \u4e00\u6761\u5206\u754c\u7ebf\uff1a\u5929\u4e0a\u8d70\u4ec0\u4e48\uff0c\u5730\u4e0a\u8d70\u4ec0\u4e48<\/h3>\n<p class=\"wp-block-paragraph\">\u4e24\u8054\u4f9b\u8fd9\u4e2a\u540d\u5b57\uff0c\u8bf4\u7684\u662f\u4e24\u5957\u672b\u7aef\uff1a\u5929\u4e0a\u7684\u7a7a\u8c03\uff0c\u5730\u4e0a\u7684\u5730\u6696\u3002\u81f3\u4e8e\u8fd9\u4e24\u5957\u672b\u7aef\u4e4b\u95f4\u7528\u4ec0\u4e48\u4ecb\u8d28\u628a\u5b83\u4eec\u8ddf\u4e3b\u673a\u8fde\u8d77\u6765\uff0c\u662f\u53e6\u4e00\u4e2a\u7ef4\u5ea6\u3002\u5206\u8def\u5c31\u5206\u5728\u300c\u5929\u4e0a\u300d\u90a3\u4e00\u6bb5\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5929\u6c1f\u5730\u6c34<\/strong>\uff1a\u5929\u4e0a\u8d70\u6c1f\uff0c\u5ba4\u5185\u673a\u662f\u6c1f\u7cfb\u7edf\uff0c\u51b7\u5a92\u76f4\u63a5\u8fdb\u623f\u95f4\u84b8\u53d1\u5438\u70ed\uff1b\u5730\u4e0a\u8d70\u6c34\uff0c\u5916\u673a\u901a\u8fc7\u4e00\u4e2a\u6c1f\u6c34\u6362\u70ed\u5668\u628a\u6c34\u52a0\u70ed\uff0c\u70ed\u6c34\u53bb\u5730\u6696\u76d8\u7ba1\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5929\u6c34\u5730\u6c34<\/strong>\uff1a\u5929\u4e0a\u8d70\u6c34\uff0c\u5ba4\u5185\u673a\u662f\u98ce\u673a\u76d8\u7ba1\uff0c\u51b7\u6c34\u70ed\u6c34\u5728\u76d8\u7ba1\u91cc\u5faa\u73af\uff1b\u5730\u4e0a\u4e5f\u8d70\u6c34\uff0c\u540c\u4e00\u5957\u6c34\u53bb\u5730\u6696\u76d8\u7ba1\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e00\u53e5\u8bdd\u8bb0\u4f4f\uff1a<strong>\u5929\u6c1f\u5730\u6c34\uff1d\u6c1f\u673a\u52a0\u5730\u6696\uff0c\u5929\u6c34\u5730\u6c34\uff1d\u6c34\u673a\u52a0\u5730\u6696\u3002<\/strong>\u4e24\u6761\u8def\u90fd\u5f52\u5728\u672c\u518c\uff0c\u56e0\u4e3a\u5ba2\u6237\u4e70\u7684\u90fd\u662f\u300c\u7a7a\u8c03\uff0b\u5730\u6696\u300d\u8fd9\u4e00\u5957\u4e1c\u897f\uff0c\u800c\u4e0d\u662f\u4e00\u4e2a\u4ecb\u8d28\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.2 \u5929\u6c1f\u5730\u6c34\u662f\u600e\u4e48\u628a\u6c34\u70e7\u70ed\u7684<\/h3>\n<p class=\"wp-block-paragraph\">\u5929\u6c1f\u5730\u6c34\u662f\u56db\u6bb5\u7ed3\u6784\uff0c\u4e00\u6bb5\u4e00\u6bb5\u770b\u5c31\u6e05\u695a\u4e86\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e00\u6bb5\uff0c\u5916\u673a\u3002<\/strong>\u538b\u7f29\u673a\u548c\u53d8\u9891\u5668\u90fd\u5728\u8fd9\u53f0\u673a\u5668\u91cc\uff0c\u4ea7\u51b7\u4ea7\u70ed\u5168\u90e8\u53d1\u751f\u5728\u8fd9\u91cc\u3002\u5916\u673a\u7684\u51b7\u91cf\u6863\u4f4d\u51b3\u5b9a\u8fd9\u5957\u7cfb\u7edf\u80fd\u5e26\u591a\u5927\u9762\u79ef\u3001\u591a\u5c11\u53f0\u5ba4\u5185\u673a\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e8c\u6bb5\uff0c\u6c1f\u6c34\u6362\u70ed\u5668\u3002<\/strong>\u8fd9\u662f\u5929\u6c1f\u5730\u6c34\u72ec\u6709\u7684\u96f6\u4ef6\uff0c\u4e5f\u662f\u6574\u6761\u8def\u4e0a\u6700\u8981\u7d27\u7684\u4e00\u6bb5\u3002\u6c1f\u4fa7\u7684\u70ed\u91cf\u5728\u8fd9\u91cc\u4ea4\u7ed9\u6c34\uff0c\u6c34\u88ab\u52a0\u70ed\u540e\u9001\u53bb\u5730\u6696\uff1b\u590f\u5929\u53cd\u8fc7\u6765\uff0c\u6c34\u88ab\u964d\u6e29\u540e\u9001\u53bb\u5730\u9762\u505a\u8f90\u5c04\u4f9b\u51b7\u3002\u8fd9\u4e00\u6bb5\u5728\u667a\u4eab AQ \u91cc\u96c6\u6210\u5728\u5916\u673a\u5185\u90e8\uff0c\u5728 NQ \u548c\u5168\u6548\u91cc\u662f\u4e00\u53f0\u72ec\u7acb\u8bbe\u5907\uff0c\u53eb\u6c34\u6a21\u5757\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e09\u6bb5\uff0c\u5730\u6696\u76d8\u7ba1\u3002<\/strong>\u6c34\u5728\u8fd9\u91cc\u6563\u70ed\u3002\u76d8\u7ba1\u600e\u4e48\u94fa\u3001\u95f4\u8ddd\u591a\u5c11\u3001\u4e3b\u7ba1\u8d70\u591a\u5927\u3001\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u4e0a\u4e8c\u6b21\u7cfb\u7edf\u2014\u2014\u8fd9\u4e00\u6bb5\u8ddf\u70ed\u6e90\u662f\u7a7a\u6c14\u80fd\u8fd8\u662f\u71c3\u6c14\u6ca1\u6709\u5173\u7cfb\uff0c\u6309 <a href=\"https:\/\/longmai-nt.com\/?page_id=669\">02 \u53f7\u624b\u518c<\/a> \u505a\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u56db\u6bb5\uff0c\u7a7a\u8c03\u4fa7\u3002<\/strong>\u5929\u6c1f\u5730\u6c34\u7684\u5ba4\u5185\u673a\u8d70\u6c1f\uff0c\u51b7\u5a92\u76f4\u63a5\u5728\u5ba4\u5185\u84b8\u53d1\u5438\u70ed\uff0c\u6240\u4ee5\u964d\u6e29\u5feb\u3001\u51fa\u98ce\u6e29\u5ea6\u4f4e\u3002\u8fd9\u4e00\u6bb5\u7684\u539f\u7406\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=667\">01 \u53f7\u624b\u518c<\/a>\uff0c\u5177\u4f53\u578b\u53f7\u4e0e\u53c2\u6570\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u300a\u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u8be6\u60c5\u9875\u300b<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u8fd9\u91cc\u6709\u4e00\u4ef6\u4e8b\u5fc5\u987b\u8bf4\u6e05\uff1a<strong>\u6c34\u6a21\u5757\u9009\u9519\uff0c\u6574\u6761\u8def\u5c31\u9519\u4e86\u3002<\/strong>\u5168\u6548\u7528\u7684\u662f\u5168\u6548\u4e13\u7528\u6c34\u6a21\u5757\uff0c\u522b\u5885\u7528\u7684\u662f\u4e24\u7ba1\u5236\u6c34\u6a21\u5757\uff0c\u4e24\u6761\u7ebf\u578b\u53f7\u53ea\u5dee\u4e00\u4e2a\u5b57\u6bcd\uff0c\u4e0d\u80fd\u4e92\u6362\u3002\u914d\u9519\u7684\u540e\u679c\u662f\u9664\u6e7f\u4e0e\u751f\u6d3b\u70ed\u6c34\u529f\u80fd\u5f02\u5e38\u3001\u8fde\u63a5\u7387\u6838\u7b97\u9519\u3001\u9a8c\u6536\u8fc7\u4e0d\u4e86\u3002\u7b7e\u5408\u540c\u524d\u628a\u5916\u673a\u578b\u53f7\u548c\u6c34\u6a21\u5757\u578b\u53f7\u5e76\u6392\u770b\u4e00\u6b21\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.3 \u5929\u6c34\u5730\u6c34\u662f\u600e\u4e48\u628a\u6c34\u70e7\u70ed\u7684<\/h3>\n<p class=\"wp-block-paragraph\">\u5929\u6c34\u5730\u6c34\u4e5f\u662f\u56db\u6bb5\uff0c\u4f46\u6027\u8d28\u4e0d\u4e00\u6837\u2014\u2014\u5b83\u5168\u7a0b\u90fd\u5728\u8ddf\u6c34\u6253\u4ea4\u9053\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e00\u6bb5\uff0c\u5916\u673a\u3002<\/strong>\u4e3b\u673a\u7684\u6362\u70ed\u5668\u76f4\u63a5\u5bf9\u6c34\uff0c\u4ea7\u51fa\u7684\u51b7\u6c34\u70ed\u6c34\u5728\u6c34\u8def\u91cc\u5faa\u73af\u3002\u6ca1\u6709\u6c1f\u6c34\u6362\u70ed\u5668\u8fd9\u4e00\u9053\u8f6c\u624b\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e8c\u6bb5\uff0c\u7f13\u51b2\u6c34\u7bb1\u3002<\/strong>\u7a33\u5b9a\u6c34\u6e29\u3001\u51cf\u5c11\u4e3b\u673a\u542f\u505c\u3002\u6c34\u7bb1\u591a\u5927\u8981\u6309\u7cfb\u7edf\u6c34\u91cf\u7b97\uff0c\u4e0d\u662f\u8d8a\u5927\u8d8a\u597d\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e09\u6bb5\uff0c\u6c34\u6cf5\u4e0e\u9600\u4ef6\u3002<\/strong>\u628a\u6c34\u9001\u5230\u5404\u4e2a\u672b\u7aef\uff0c\u5e76\u4fdd\u8bc1\u6bcf\u4e2a\u672b\u7aef\u62ff\u5230\u7684\u6d41\u91cf\u591f\u3002\u6c34\u529b\u4e0d\u5e73\u8861\u662f\u6c34\u7cfb\u7edf\u6700\u5e38\u89c1\u7684\u75c5\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u56db\u6bb5\uff0c\u672b\u7aef\u3002<\/strong>\u7a7a\u8c03\u4fa7\u662f\u98ce\u673a\u76d8\u7ba1\uff0c\u6c34\u76d8\u7ba1\u52a0\u98ce\u673a\uff1b\u5730\u6696\u4fa7\u662f\u76d8\u7ba1\uff0c\u8ddf\u5929\u6c1f\u5730\u6c34\u7528\u7684\u662f\u540c\u4e00\u5957\u505a\u6cd5\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u591a\u51fa\u6765\u7684\u6c34\u7bb1\u3001\u6c34\u6cf5\u3001\u9600\u95e8\u3001\u6c34\u7ba1\u4fdd\u6e29\uff0c\u662f\u8fd9\u6761\u8def\u7684\u521d\u6295\u8d44\u548c\u5360\u4f4d\u6210\u672c\uff1b\u6362\u6765\u7684\u662f\u6c34\u84c4\u51b7\u3001\u957f\u8ddd\u79bb\u8f93\u9001\u3001\u591a\u5206\u533a\u597d\u505a\u3002\u7cfb\u7edf\u67b6\u6784\u7684\u5168\u90e8\u7ec6\u8282\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u300a\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66\u300b<\/a>\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.4 \u516d\u4e2a\u7ef4\u5ea6\u5bf9\u4e00\u6b21<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u5929\u6c1f\u5730\u6c34<\/strong><\/td>\n<td><strong>\u5929\u6c34\u5730\u6c34<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u4e0a\u90a3\u4e00\u6bb5<\/strong><\/td>\n<td>\u6c1f\uff0c\u51b7\u5a92\u76f4\u63a5\u8fdb\u5ba4\u5185\u673a<\/td>\n<td>\u6c34\uff0c\u98ce\u673a\u76d8\u7ba1\u8d70\u51b7\u6c34\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td><strong>\u964d\u6e29\u901f\u5ea6<\/strong><\/td>\n<td>\u5feb\uff0c\u51fa\u98ce\u6e29\u5ea6\u4f4e<\/td>\n<td>\u7a0d\u7f13\uff0c\u6c34\u6709\u84c4\u51b7\u60ef\u6027<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6e29\u6e7f\u5206\u5f00\u63a7<\/strong><\/td>\n<td>\u5168\u6548\u914d\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u53ef\u505a\u5230<\/td>\n<td>\u9760\u6c34\u6e29\u4e0e\u98ce\u91cf\uff0c\u9664\u6e7f\u8981\u4f4e\u6e29\u6c34\uff0c\u5bb9\u6613\u8fc7\u51b7<\/td>\n<\/tr>\n<tr>\n<td><strong>\u521d\u6295\u8d44<\/strong><\/td>\n<td>\u8f83\u4f4e\uff0c\u5c11\u6c34\u7bb1\u3001\u6c34\u6cf5\u4e0e\u9600\u4ef6<\/td>\n<td>\u8f83\u9ad8\uff0c\u591a\u6c34\u7bb1\u3001\u6c34\u6cf5\u3001\u9600\u4ef6\u4e0e\u6c34\u7ba1\u4fdd\u6e29<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8bbe\u5907\u5360\u4f4d<\/strong><\/td>\n<td>\u5c11\uff0c\u591a\u4e00\u53f0\u6c34\u6a21\u5757<\/td>\n<td>\u591a\uff0c\u8981\u6c34\u7bb1\u4e0e\u8bbe\u5907\u4f4d<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ef4\u62a4\u9762<\/strong><\/td>\n<td>\u6c1f\u8def\u5c01\u95ed\uff0c\u6545\u969c\u70b9\u5c11<\/td>\n<td>\u6c34\u8def\u9600\u95e8\u6c34\u6cf5\u591a\uff0c\u8981\u5b9a\u671f\u67e5\u6f0f\u4e0e\u6e05\u6d17<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u8fd9\u5f20\u8868\u4e0d\u662f\u7528\u6765\u5206\u9ad8\u4e0b\u7684\u3002\u4e24\u6761\u8def\u5404\u6709\u5404\u7684\u9002\u7528\u9762\uff0c\u9009\u9519\u7684\u4ee3\u4ef7\u8fdc\u5927\u4e8e\u9009\u8d35\u4e00\u70b9\u3002\u4e24\u6761\u8def\u600e\u4e48\u9009\uff0c<a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u300a\u6210\u90fd\u6c34\u673a vs \u6c1f\u673a\uff1a\u4e24\u8054\u4f9b\u600e\u4e48\u9009\u300b<\/a>\u91cc\u6709\u6309\u6237\u578b\u5bf9\u53f7\u5165\u5ea7\u7684\u51b3\u7b56\u8868\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.5 \u5929\u6c1f\u5730\u6c34\u7684\u56db\u79cd\u5f62\u6001<\/h3>\n<p class=\"wp-block-paragraph\">\u5929\u6c1f\u5730\u6c34\u4e0d\u662f\u4e00\u4e2a\u578b\u53f7\uff0c\u662f\u56db\u79cd\u914d\u6cd5\u3002\u5dee\u522b\u5728\u4e09\u5904\uff1a\u6c34\u6a21\u5757\u5728\u4e0d\u5728\u673a\u5668\u91cc\u3001\u6709\u6ca1\u6709\u751f\u6d3b\u70ed\u6c34\u3001\u5ba4\u5185\u673a\u5e26\u4e0d\u5e26\u4e09\u6839\u7ba1\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u914d\u6cd5<\/strong><\/td>\n<td><strong>\u5f62\u6001<\/strong><\/td>\n<td><strong>\u6c34\u6a21\u5757<\/strong><\/td>\n<td><strong>\u5ba4\u5185\u673a<\/strong><\/td>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u667a\u4eab AQ<\/strong><\/td>\n<td>\u4e00\u4f53\u673a<\/td>\n<td>\u5185\u7f6e\u5728\u5916\u673a\u91cc<\/td>\n<td>\u901a\u7528\u5185\u673a<\/td>\n<td>\u5e26\uff0c\u70ed\u56de\u6536<\/td>\n<\/tr>\n<tr>\n<td><strong>\u667a\u4eab NQ<\/strong><\/td>\n<td>\u4e00\u4f53\u673a<\/td>\n<td>\u5185\u7f6e\u5728\u5916\u673a\u91cc<\/td>\n<td>\u901a\u7528\u5185\u673a<\/td>\n<td>\u4e0d\u5e26<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5c0a\u777f\u5168\u6548\u2161<\/strong><\/td>\n<td>\u5206\u4f53\u673a<\/td>\n<td>\u5916\u7f6e\uff0c\u5168\u6548\u4e13\u7528\u6c34\u6a21\u5757<\/td>\n<td>\u4e09\u7ba1\u5236<\/td>\n<td>\u53ef\u914d\u70ed\u6c34\u7bb1\u6210\u4e09\u8054\u4f9b<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5c0a\u777f\u522b\u5885<\/strong><\/td>\n<td>\u5206\u4f53\u673a<\/td>\n<td>\u5916\u7f6e\uff0c\u4e24\u7ba1\u5236\u6c34\u6a21\u5757\uff0c\u53ef\u63a5 2 \u5230 3 \u53f0<\/td>\n<td>\u4e24\u7ba1\u5236<\/td>\n<td>\u6309\u9700<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u63a7\u5236\u5668\u578b\u53f7\u8fd9\u4e9b\u9010\u9879\u53c2\u6570\uff0c\u672c\u518c\u4e0d\u590d\u8ff0\u2014\u2014\u56db\u5f20\u8868\u90fd\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u300a\u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u8be6\u60c5\u9875\u300b<\/a>\uff0c\u5168\u6548\u90a3\u4e00\u53f0\u7684\u8be6\u7ec6\u8d44\u6599\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u300a\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\u300b<\/a>\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.6 \u4ec0\u4e48\u65f6\u5019\u8be5\u9009\u5929\u6c34\u5730\u6c34<\/h3>\n<p class=\"wp-block-paragraph\">\u53cd\u8fc7\u6765\u95ee\u66f4\u597d\u7528\uff1a\u4ec0\u4e48\u623f\u5b50\u4e0d\u9002\u5408\u5929\u6c1f\u5730\u6c34\uff0c\u53ea\u80fd\u8d70\u6c34\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u9762\u79ef\u5927\u3001\u672b\u7aef\u591a\u3001\u7ba1\u8def\u957f\u3002<\/strong>\u6c1f\u7ba1\u7684\u957f\u5ea6\u6709\u9650\u5236\uff0c\u6c34\u8def\u8f93\u9001\u8ddd\u79bb\u957f\u5f97\u591a\u3002\u4e09\u56db\u767e\u5e73\u65b9\u7c73\u4ee5\u4e0a\u3001\u5c42\u6570\u591a\u3001\u7ba1\u8def\u62c9\u5f97\u8fdc\u7684\u623f\u5b50\uff0c\u6c34\u7cfb\u7edf\u66f4\u597d\u505a\u3002<\/li>\n<li><strong>\u8981\u591a\u5206\u533a\u72ec\u7acb\u63a7\u6e29\u3002<\/strong>\u6c34\u8def\u5929\u7136\u9002\u5408\u5206\u533a\u5206\u8def\uff0c\u6bcf\u8def\u4e00\u4e2a\u9600\u95e8\uff1b\u6c1f\u7cfb\u7edf\u5206\u623f\u95f4\u9760\u7684\u662f\u5ba4\u5185\u673a\u672c\u8eab\u3002<\/li>\n<li><strong>\u9700\u8981\u6c34\u84c4\u51b7\u524a\u5cf0\u3002<\/strong>\u5927\u9762\u79ef\u540c\u65f6\u5f00\u7a7a\u8c03\u65f6\uff0c\u6c34\u7bb1\u80fd\u5403\u6389\u4e00\u90e8\u5206\u77ac\u65f6\u8d1f\u8377\uff0c\u4e3b\u673a\u542f\u505c\u6b21\u6570\u5c11\u3002<\/li>\n<li><strong>\u5ba2\u6237\u660e\u786e\u8981\u6c34\u7cfb\u7edf\u3002<\/strong>\u6709\u4e9b\u5ba2\u6237\u7528\u8fc7\u6c34\u673a\u3001\u8ba4\u8fd9\u5957\uff0c\u4e0d\u5fc5\u5f3a\u884c\u6539\u3002<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">\u53cd\u8fc7\u6765\u8bf4\uff0c\u516c\u5bd3\u3001\u4e5d\u5341\u5230\u4e00\u767e\u516d\u5341\u5e73\u65b9\u7c73\u7684\u5e73\u5c42\u3001\u5916\u673a\u4f4d\u7d27\u5f20\u3001\u60f3\u4e00\u673a\u628a\u7a7a\u8c03\u5730\u6696\u70ed\u6c34\u5168\u89e3\u51b3\uff0c\u5929\u6c1f\u5730\u6c34\u66f4\u5408\u9002\u2014\u2014\u4e00\u53f0\u673a\u5668\u5c31\u662f\u4e00\u5957\u7cfb\u7edf\u3002<\/p>\n<h3 class=\"wp-block-heading\">2.7 \u4e09\u4e2a\u6700\u5e38\u89c1\u7684\u8bef\u533a<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a\u4e00\uff1a\u4e24\u8054\u4f9b\u5c31\u662f\u6c34\u673a\u3002<\/strong>\u4e0d\u662f\u3002\u4e24\u8054\u4f9b\u8bf4\u7684\u662f\u4e24\u5957\u672b\u7aef\uff0c\u4e0d\u662f\u4e00\u4e2a\u4ecb\u8d28\u3002\u5929\u6c1f\u5730\u6c34\u4e5f\u5c5e\u4e8e\u4e24\u8054\u4f9b\uff0c\u800c\u4e14\u5728\u5bb6\u7528\u5e02\u573a\u5360\u6bd4\u66f4\u5927\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a\u4e8c\uff1a\u5929\u6c1f\u5730\u6c34\u505a\u4e0d\u5230\u9664\u6e7f\u4e0d\u964d\u6e29\u3002<\/strong>\u80fd\uff0c\u4f46\u53ea\u6709\u4e00\u79cd\u914d\u6cd5\u80fd\u505a\u5230\uff1a\u5168\u6548\u5916\u673a\u914d\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u3002\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u53ea\u80fd\u914d\u5168\u6548\u5916\u673a\uff0c\u914d\u4e0d\u5230 AQ \u548c NQ \u4e0a\uff0c\u8fd9\u662f\u5382\u65b9\u7684\u786c\u89c4\u5219\uff0c\u4e0d\u662f\u642d\u914d\u5efa\u8bae\u3002\u6240\u4ee5\u8981\u6e29\u6e7f\u5206\u5f00\u63a7\uff0c\u9009\u578b\u65f6\u5148\u628a\u5168\u6548\u5b9a\u4e0b\u6765\uff0c\u518d\u8c08\u5176\u4ed6\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a\u4e09\uff1a\u6c34\u673a\u4e00\u5b9a\u66f4\u8212\u670d\u3002<\/strong>\u8212\u9002\u5ea6\u6765\u81ea\u672b\u7aef\u5f62\u5f0f\u548c\u6c34\u529b\u8bbe\u8ba1\uff0c\u4e0d\u6765\u81ea\u4ecb\u8d28\u3002\u5730\u6696\u5728\u4e24\u6761\u8def\u4e0a\u662f\u540c\u4e00\u5957\u505a\u6cd5\uff1b\u7a7a\u8c03\u4fa7\u7684\u771f\u6b63\u5dee\u522b\uff0c\u662f\u964d\u6e29\u5feb\u6162\u548c\u6e7f\u5ea6\u7684\u63a7\u5236\u65b9\u5f0f\uff0c\u4e0d\u662f\u300c\u6c34\u5c31\u67d4\u548c\u3001\u6c1f\u5c31\u786c\u300d\u8fd9\u79cd\u8bf4\u6cd5\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e09\u90e8\u5206\uff1a\u6c34\u7cfb\u7edf\u7684\u4e3b\u673a\u81ea\u7531\u2014\u2014\u70ed\u6e90\u4e0e\u672b\u7aef\u4e3a\u4ec0\u4e48\u80fd\u62c6\u5f00\u914d<\/h2>\n<p class=\"wp-block-paragraph\">\u4e0a\u4e00\u90e8\u5206\u8bb2\u7684\u662f\u4e24\u6761\u8def\u600e\u4e48\u5206\uff1a\u5929\u4e0a\u8d70\u6c1f\u8fd8\u662f\u8d70\u6c34\u3002\u8fd9\u4e00\u90e8\u5206\u53ea\u8bb2\u8d70\u6c34\u90a3\u4e00\u6761\u7684\u72ec\u6709\u6027\u8d28\u2014\u2014<strong>\u4e3b\u673a\u548c\u672b\u7aef\u53ef\u4ee5\u62c6\u5f00\u914d<\/strong>\u3002\u8fd9\u4e0d\u662f\u6211\u4eec\u603b\u7ed3\u51fa\u6765\u7684\u5356\u70b9\uff0c\u662f\u6c34\u8def\u8fd9\u4e2a\u63a5\u53e3\u672c\u8eab\u51b3\u5b9a\u7684\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.1 \u4e00\u4e2a\u63a5\u53e3\uff0c\u51b3\u5b9a\u4e86\u4e00\u5207<\/h3>\n<p class=\"wp-block-paragraph\">\u6c34\u7cfb\u7edf\u548c\u6c1f\u7cfb\u7edf\u6700\u5927\u7684\u533a\u522b\uff0c\u4e0d\u5728\u80fd\u6548\u3001\u4e0d\u5728\u8212\u9002\u5ea6\uff0c\u5728\u63a5\u53e3\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6c1f\u7cfb\u7edf\u7684\u63a5\u53e3\u662f\u51b7\u5a92\u7ba1\u3002\u51b7\u5a92\u4ece\u538b\u7f29\u673a\u51fa\u6765\uff0c\u7ecf\u7535\u5b50\u81a8\u80c0\u9600\u5206\u914d\u5230\u6bcf\u4e00\u53f0\u5185\u673a\uff0c\u4e2d\u95f4\u7684\u538b\u529b\u3001\u6d41\u91cf\u3001\u56de\u6cb9\u3001\u63a7\u5236\u4fe1\u53f7\uff0c\u5168\u90fd\u7531\u5382\u5bb6\u81ea\u5df1\u90a3\u4e00\u5957\u534f\u8bae\u7ba1\u7740\u3002\u8fd9\u610f\u5473\u7740\u4e3b\u673a\u548c\u5185\u673a\u5fc5\u987b\u540c\u54c1\u724c\u3001\u540c\u7cfb\u5217\u3001\u540c\u4e00\u5957\u63a7\u5236\u903b\u8f91\u2014\u2014\u628a A \u5bb6\u7684\u5916\u673a\u63a5 B \u5bb6\u7684\u5185\u673a\uff0c\u7269\u7406\u4e0a\u63a5\u5f97\u4e0a\uff0c\u63a7\u5236\u4e0a\u8dd1\u4e0d\u8d77\u6765\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6c34\u7cfb\u7edf\u7684\u63a5\u53e3\u662f\u6c34\u3002\u4e3b\u673a\u548c\u6c34\u8def\u4e4b\u95f4\u53ea\u6709\u4e24\u4e2a\u6570\uff1a<strong>\u8fdb\u51fa\u6c34\u6e29<\/strong>\u548c<strong>\u6d41\u91cf<\/strong>\u3002\u53ea\u8981\u8fd9\u4e24\u6837\u5bf9\u5f97\u4e0a\uff0c\u6c34\u4e0d\u8ba4\u54c1\u724c\u3001\u4e0d\u8ba4\u578b\u53f7\u3001\u4e0d\u8ba4\u54ea\u4e00\u5e74\u751f\u4ea7\u7684\u3002\u4e3b\u673a\u628a\u6c34\u70e7\u5230 45 \u5ea6\u9001\u51fa\u53bb\uff0c\u672b\u7aef\u5c31\u7528\u8fd9 45 \u5ea6\u7684\u6c34\u6563\u70ed\uff0c\u4e2d\u95f4\u6ca1\u6709\u534f\u8bae\u53ef\u8c08\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u8fd9\u4e00\u6761\u5dee\u5f02\u5f80\u4e0b\u63a8\uff0c\u5c31\u662f\u4e3b\u673a\u81ea\u7531\u548c\u672b\u7aef\u81ea\u7531\u3002\u5b83\u5e26\u6765\u7684\u4e0d\u53ea\u662f\u9009\u578b\u65b9\u4fbf\uff0c\u8fd8\u6709\u4e00\u4ef6\u66f4\u5b9e\u5728\u7684\u4e8b\uff1a<strong>\u5730\u6696\u7ba1\u8def\u6309 50 \u5e74\u7b97\uff0c\u4e3b\u673a\u6309 12 \u5230 15 \u5e74\u7b97<\/strong>\u3002\u8d70\u6c34\uff0c\u4e3b\u673a\u5230\u671f\u6362\u4e00\u53f0\uff0c\u5730\u9762\u4e0d\u7528\u52a8\uff1b\u8d70\u6c1f\uff0c\u4e3b\u673a\u4e00\u6362\uff0c\u5185\u673a\u548c\u7ba1\u8def\u90fd\u8981\u8ddf\u7740\u8003\u8651\u3002\u8fd9\u4e00\u70b9\u8ddf\u5ba2\u6237\u8bb2\u7684\u65f6\u5019\u8981\u8bf4\u51c6\u2014\u2014\u6c34\u6cf5\u3001\u9600\u95e8\u3001\u7ebf\u63a7\u5668\u8be5\u7ef4\u62a4\u8fd8\u662f\u8981\u7ef4\u62a4\uff0c\u4e0d\u662f\u88c5\u4e0a\u5c31\u4e00\u52b3\u6c38\u9038\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u6c1f\u7cfb\u7edf\uff08\u591a\u8054\u673a\uff09<\/strong><\/td>\n<td><strong>\u6c34\u7cfb\u7edf\uff08\u5929\u6c34\u5730\u6c34\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u4e0e\u672b\u7aef\u4e4b\u95f4\u9760\u4ec0\u4e48\u8fde<\/td>\n<td>\u51b7\u5a92\u7ba1\uff0c\u538b\u529b\u3001\u6d41\u91cf\u3001\u56de\u6cb9\u3001\u534f\u8bae\u90fd\u7531\u5382\u5bb6\u4e00\u5957\u7ba1\u7740<\/td>\n<td>\u6c34\u7ba1\uff0c\u53ea\u770b\u8fdb\u51fa\u6c34\u6e29\u548c\u6d41\u91cf<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u548c\u5185\u673a\u5fc5\u987b\u540c\u54c1\u724c\u5417<\/td>\n<td>\u5fc5\u987b\uff0c\u540c\u54c1\u724c\u540c\u7cfb\u5217\u540c\u4e00\u5957\u63a7\u5236\u903b\u8f91<\/td>\n<td>\u4e0d\u5fc5\uff0c\u6c34\u8def\u8fd9\u4e00\u5c42\u4e0d\u8ba4\u54c1\u724c<\/td>\n<\/tr>\n<tr>\n<td>\u60f3\u6362\u70ed\u6e90<\/td>\n<td>\u6574\u673a\u66f4\u6362\uff0c\u5185\u673a\u7cfb\u7edf\u8981\u8ddf\u7740\u91cd\u914d<\/td>\n<td>\u53ea\u6362\u4e3b\u673a\uff0c\u5730\u9762\u7ba1\u8def\u4e0d\u52a8<\/td>\n<\/tr>\n<tr>\n<td>\u60f3\u6362\u672b\u7aef<\/td>\n<td>\u53d7\u63a7\u5236\u534f\u8bae\u9650\u5236<\/td>\n<td>\u53d7\u6c34\u6e29\u6863\u4f4d\u9650\u5236<\/td>\n<\/tr>\n<tr>\n<td>\u591a\u53f0\u4e3b\u673a\u5e76\u8054<\/td>\n<td>\u53d7\u53f0\u6570\u4e0e\u8fde\u63a5\u7387\u7ea6\u675f<\/td>\n<td>\u5b98\u65b9\u652f\u6301\u6700\u591a\u56db\u53f0\u3001\u4e0d\u540c\u529f\u7387\u6df7\u62fc<\/td>\n<\/tr>\n<tr>\n<td>\u8054\u52a8\u63a7\u5236<\/td>\n<td>\u51fa\u5382\u5c31\u5199\u5728\u4e3b\u677f\u91cc<\/td>\n<td>\u8981\u73b0\u573a\u914d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u8fd9\u5f20\u8868\u6700\u540e\u4e00\u884c\u7684\u4ee3\u4ef7\uff0c\u662f\u672c\u90e8\u5206 3.6 \u8981\u8bb2\u7684\u91cd\u70b9\u3002\u524d\u9762\u4e94\u884c\u7684\u81ea\u7531\u662f\u771f\u7684\uff0c\u6700\u540e\u4e00\u884c\u7684\u8d26\u4e5f\u662f\u771f\u7684\u8981\u4ed8\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.2 \u70ed\u6e90\u53ef\u4ee5\u50cf\u58c1\u6302\u7089\u4e00\u6837\u6311<\/h3>\n<p class=\"wp-block-paragraph\">\u56e0\u4e3a\u63a5\u53e3\u662f\u6c34\uff0c\u70ed\u6e90\u8fd9\u4e00\u7aef\u5c31\u53d8\u6210\u4e86\u4e00\u4e2a\u5f00\u653e\u7684\u6c34\u6e29\u6e90\u3002\u5730\u6696\u76d8\u7ba1\u57cb\u5728\u5730\u9762\u91cc\uff0c\u5b83\u53ea\u8ba4\u300c\u8fdb\u6765\u591a\u5c11\u5ea6\u7684\u6c34\u3001\u7ed9\u591a\u5927\u6d41\u91cf\u300d\uff0c\u4e0d\u8ba4\u8fd9\u6c34\u662f\u8c01\u70e7\u7684\u3002\u8fd9\u8ddf\u5730\u6696\u914d\u58c1\u6302\u7089\u662f\u4e00\u4e2a\u9053\u7406\u2014\u2014\u58c1\u6302\u7089\u80fd\u5e26\u7684\u5730\u6696\uff0c\u7a7a\u6c14\u80fd\u4e5f\u80fd\u5e26\uff0c\u53cd\u8fc7\u6765\u4e5f\u4e00\u6837\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u70ed\u6e90<\/strong><\/td>\n<td><strong>\u5e38\u7528\u51fa\u6c34\u6e29\u5ea6<\/strong><\/td>\n<td><strong>\u4ec0\u4e48\u60c5\u51b5\u4f1a\u9009\u5b83<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u58c1\u6302\u7089<\/td>\n<td>40~80\u2103<\/td>\n<td>\u8001\u623f\u3001\u6c14\u4ef7\u4f4e\u3001\u8981\u540c\u65f6\u89e3\u51b3\u751f\u6d3b\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u6e90\u70ed\u6cf5<\/td>\n<td>35~55\u2103<\/td>\n<td>\u4e3b\u529b\u65b9\u6848\uff0c\u7528\u7535\u4ee3\u66ff\u71c3\u6c14<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u5730\u6e90\u70ed\u6cf5<\/td>\n<td>40~50\u2103<\/td>\n<td>\u6709\u6253\u4e95\u6761\u4ef6\u3001\u5730\u5757\u591f\u5927\u7684\u522b\u5885<\/td>\n<\/tr>\n<tr>\n<td>\u592a\u9633\u80fd \/ \u96c6\u4e2d\u4f9b\u70ed<\/td>\n<td>\u6309\u7cfb\u7edf\u5b9a<\/td>\n<td>\u505a\u8865\u5145\u70ed\u6e90\uff0c\u6216\u5c0f\u533a\u5df2\u6709\u70ed\u7f51<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u6240\u4ee5\u5bf9\u5ba2\u6237\u53ef\u4ee5\u8fd9\u6837\u8bb2\uff1a\u8fd9\u5957\u5730\u6696\u5c06\u6765\u60f3\u6362\u70ed\u6e90\uff0c\u7ba1\u8def\u4e0d\u7528\u91cd\u94fa\u3002\u4f46\u6362\u4e4b\u524d\u8981\u6838\u4e09\u6837\u2014\u2014\u51fa\u6c34\u6e29\u5ea6\u591f\u4e0d\u591f\u3001\u6d41\u91cf\u7ed9\u4e0d\u7ed9\u5f97\u8d77\u3001\u672b\u7aef\u627f\u4e0d\u627f\u53d7\u5f97\u4f4f\u3002\u4e09\u6837\u5bf9\u4e0a\u624d\u53eb\u80fd\u6362\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.3 \u672b\u7aef\u4e5f\u53ef\u4ee5\u6362\u7740\u914d<\/h3>\n<p class=\"wp-block-paragraph\">\u53cd\u8fc7\u6765\u4e5f\u6210\u7acb\uff1a\u4e00\u4e2a\u6c34\u73af\u8def\u53ef\u4ee5\u5e26\u4e0d\u540c\u7684\u672b\u7aef\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u5730\u6696\u76d8\u7ba1<\/strong>\uff1a\u5730\u9762\u8f90\u5c04\uff0c\u6c34\u6e29 35~45\u2103<\/li>\n<li><strong>\u98ce\u673a\u76d8\u7ba1<\/strong>\uff1a\u7a7a\u8c03\u4fa7\uff0c\u590f\u5929 7~12\u2103 \u4f9b\u51b7\uff0c\u51ac\u5929 45~50\u2103 \u4f9b\u70ed<\/li>\n<li><strong>\u6696\u6c14\u7247<\/strong>\uff1a\u9ad8\u6e29\u6c34\uff0c\u4e00\u822c\u8981 60~80\u2103<\/li>\n<li><strong>\u8f90\u5c04\u677f\u3001\u6bdb\u7ec6\u7ba1<\/strong>\uff1a\u4f4e\u6e29\u5927\u9762\u79ef\uff0c\u6c34\u6e29\u66f4\u4f4e<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">\u8981\u6ce8\u610f\u7684\u4e0d\u662f\u300c\u80fd\u4e0d\u80fd\u63a5\u300d\uff0c\u800c\u662f<strong>\u6c34\u6e29\u5bf9\u4e0d\u5bf9\u5f97\u4e0a<\/strong>\u3002\u5730\u6696\u548c\u98ce\u673a\u76d8\u7ba1\u53ef\u4ee5\u5171\u7528\u4e00\u4e2a\u51b7\u70ed\u6e90\uff1a\u590f\u5929 7 \u5ea6\u4f9b\u51b7\u8d70\u98ce\u76d8\uff0c\u51ac\u5929 45 \u5ea6\u4f9b\u70ed\u8d70\u5730\u6696\u3002\u6696\u6c14\u7247\u8981 60 \u5ea6\u4ee5\u4e0a\uff0c\u666e\u901a\u70ed\u6cf5\u51fa\u6c34\u6e29\u5ea6\u4e0d\u591f\uff0c\u5c31\u5f97\u914d\u9ad8\u6e29\u673a\u578b\u6216\u8005\u52a0\u6df7\u6c34\u88c5\u7f6e\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6240\u4ee5\u672b\u7aef\u81ea\u7531\u662f\u6709\u6761\u4ef6\u7684\u81ea\u7531\uff1a<strong>\u540c\u4e00\u6c34\u6e29\u6863\u7684\u672b\u7aef\u53ef\u4ee5\u6df7\uff0c\u8de8\u6c34\u6e29\u6863\u7684\u8981\u52a0\u88c5\u7f6e<\/strong>\u3002\u7ba1\u8def\u548c\u6df7\u6c34\u8fd9\u5957\u505a\u6cd5\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=669\">02 \u53f7\u624b\u518c<\/a> \u91cc\uff0c\u672c\u518c\u53ea\u70b9\u5230\u6c34\u6e29\u8fd9\u4e00\u5c42\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.4 \u591a\u4e3b\u673a\u5e76\u8054\uff0c\u5b98\u65b9\u652f\u6301\u5230\u56db\u53f0<\/h3>\n<p class=\"wp-block-paragraph\">\u4e3b\u673a\u81ea\u7531\u8fd8\u6709\u4e00\u4e2a\u5f62\u6001\uff1a\u4e0d\u662f\u6362\u54c1\u724c\uff0c\u800c\u662f\u591a\u53f0\u4e00\u8d77\u4e0a\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5382\u5bb6\u8d44\u6599\u5199\u660e\uff0c\u6700\u591a\u56db\u53f0\u4e3b\u673a\u5e76\u8054\uff0c\u540c\u7cfb\u5217\u5185\u4e0d\u540c\u529f\u7387\u53ef\u4ee5\u6df7\u62fc\uff0c\u6309\u9700\u5f00\u542f\u3001\u4e92\u4e3a\u5907\u7528\u3002\u4e24\u4e2a\u597d\u5904\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u90e8\u5206\u8d1f\u8377\u6548\u7387<\/strong>\uff1a\u767d\u5929\u53ea\u5f00\u5ba2\u5385\u90a3\u4e00\u53f0\uff0c\u665a\u4e0a\u518d\u5e76\u4e00\u53f0\uff0c\u4e0d\u5fc5\u4e3a\u4e86\u5076\u5c14\u7684\u5168\u5f00\u53bb\u914d\u4e00\u53f0\u5927\u673a\u5668<\/li>\n<li><strong>\u6545\u969c\u5197\u4f59<\/strong>\uff1a\u4e00\u53f0\u68c0\u4fee\uff0c\u53e6\u4e00\u53f0\u8fd8\u80fd\u9876\u4f4f\u57fa\u672c\u8d1f\u8377<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">\u4ee3\u4ef7\u662f\u7ba1\u8def\u8981\u6309\u5e76\u8054\u505a\u2014\u2014\u6c34\u529b\u5e73\u8861\u3001\u6c34\u6e29\u540c\u6b65\u3001\u4e3b\u4ece\u5207\u6362\u90fd\u5f97\u8bbe\u8ba1\u8fdb\u53bb\u3002\u8fd9\u5957\u505a\u6cd5\u6709\u5382\u5bb6\u7684\u7cfb\u7edf\u56fe\u53ef\u4f9d\uff0c\u4e0d\u662f\u73b0\u573a\u81ea\u5df1\u62fc\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.5 \u6309\u540c\u5f00\u7387\u9009\u578b\uff0c\u4e0d\u53d7\u8fde\u63a5\u7387\u5361<\/h3>\n<p class=\"wp-block-paragraph\">\u6c1f\u7cfb\u7edf\u6709\u4e00\u6761\u786c\u7ea6\u675f\uff1a\u5185\u673a\u603b\u529f\u7387\u9664\u4ee5 1.3\uff0c\u7b49\u4e8e\u5916\u673a\u7684\u6700\u5c0f\u529f\u7387\u3002\u56e0\u4e3a\u51b7\u5a92\u76f4\u63a5\u8fdb\u5185\u673a\uff0c\u5168\u5f00\u65f6\u538b\u7f29\u673a\u625b\u4e0d\u4f4f\uff0c\u4f1a\u62a5\u6545\u969c\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6c34\u7cfb\u7edf\u6ca1\u6709\u8fd9\u4e00\u6761\u3002\u538b\u7f29\u673a\u4e0d\u76f4\u63a5\u9762\u5bf9\u672b\u7aef\uff0c\u6d41\u91cf\u7531\u6c34\u6cf5\u51b3\u5b9a\uff0c\u6240\u4ee5\u53ef\u4ee5\u6309<strong>\u5b9e\u9645\u540c\u65f6\u5f00\u542f\u7684\u8d1f\u8377<\/strong>\u9009\u4e3b\u673a\u2014\u2014170 \u5e73\u65b9\u7c73\u7684\u623f\u5b50\uff0c\u5ba2\u5385\u52a0\u4e24\u95f4\u5367\u5ba4\u5e38\u5f00\uff0c\u6309\u8fd9\u4e2a\u8d1f\u8377\u914d\u5c31\u884c\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4f46\u6709\u4e00\u6761\u786c\u7ea6\u675f\u4e0d\u80fd\u5fd8\uff1a<strong>\u5730\u6696\u662f\u8fde\u7eed\u8d1f\u8377<\/strong>\u3002\u5168\u5c4b\u5730\u6696\u5f00\u7740\uff0c\u70ed\u91cf\u662f\u4e00\u76f4\u8981\u7684\uff0c\u8bbe\u8ba1\u8d1f\u8377\u4e0d\u4f4e\u4e8e 100 \u74e6\u6bcf\u5e73\u65b9\u7c73\uff0c\u8fd9\u4e00\u5934\u4e0d\u80fd\u6309\u540c\u5f00\u7387\u6253\u6298\u3002\u6240\u4ee5\u6c34\u7cfb\u7edf\u7684\u6b63\u786e\u7b97\u6cd5\u662f\uff1a\u7a7a\u8c03\u4fa7\u6309\u540c\u5f00\u7387\uff0c\u5730\u6696\u4fa7\u6309\u5168\u8d1f\u8377\uff0c\u53d6\u5927\u7684\u90a3\u4e2a\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u8fd9\u4e00\u8282\u548c\u7b2c\u5341\u4e00\u90e8\u5206\u300c\u5c0f\u9a6c\u62c9\u5927\u8f66\u300d\u662f\u540c\u4e00\u4ef6\u4e8b\u7684\u4e24\u9762\uff1a\u90a3\u8fb9\u8bb2\u5ba2\u6237\u600e\u4e48\u4f1a\u8fd9\u4e48\u95ee\uff0c\u8fd9\u8fb9\u8bb2\u9009\u578b\u8be5\u600e\u4e48\u7b97\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.6 \u81ea\u7531\u7684\u8d26\u5355\uff1a\u8054\u52a8\u63a7\u5236<\/h3>\n<p class=\"wp-block-paragraph\">\u4e0a\u9762\u8bb2\u7684\u90fd\u662f\u597d\u5904\uff0c\u73b0\u5728\u8bb2\u4ee3\u4ef7\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6c34\u7cfb\u7edf\u7684\u81ea\u7531\u5ea6\uff0c\u662f\u628a\u539f\u672c\u7531\u5382\u5bb6\u6253\u5305\u597d\u7684\u4e8b\uff0c\u644a\u5230\u4e86\u8bbe\u8ba1\u548c\u65bd\u5de5\u4e0a\u3002\u4e3b\u673a\u3001\u6c34\u6cf5\u3001\u5185\u673a\uff08\u98ce\u673a\u76d8\u7ba1\uff09\u3001\u672b\u7aef\uff0c\u8fd9\u56db\u6837\u8981\u8054\u52a8\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5f00\u54ea\u53f0\u5185\u673a\uff0c\u4e3b\u673a\u8981\u4e0d\u8981\u542f\u52a8\u3001\u6c34\u6cf5\u8981\u4e0d\u8981\u63d0\u901f<\/li>\n<li>\u5730\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u540c\u65f6\u8981\u70ed\uff0c\u8c01\u4f18\u5148<\/li>\n<li>\u51ac\u5929\u9632\u51bb\u3001\u590f\u5929\u9632\u7ed3\u9732\uff0c\u8c01\u6765\u515c\u5e95<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">\u8fd9\u5957\u8054\u52a8\uff0c\u6c1f\u7cfb\u7edf\u662f\u51fa\u5382\u5c31\u5199\u597d\u5728\u4e3b\u677f\u91cc\u7684\uff0c\u6c34\u7cfb\u7edf\u8981\u73b0\u573a\u914d\u3002\u914d\u4e0d\u597d\u4f1a\u51fa\u73b0\u4e24\u79cd\u60c5\u51b5\uff1a\u6c34\u6cf5 24 \u5c0f\u65f6\u7a7a\u8f6c\uff0c\u7535\u8d39\u767d\u70e7\uff1b\u6216\u8005\u672b\u7aef\u5f00\u4e86\u4e3b\u673a\u4e0d\u542f\u52a8\uff0c\u5ba2\u6237\u4ee5\u4e3a\u8bbe\u5907\u574f\u4e86\u3002\u8fd9\u4e24\u79cd\u5728\u73b0\u573a\u90fd\u4e0d\u5c11\u89c1\uff0c\u5c5e\u4e8e\u8bbe\u8ba1\u9636\u6bb5\u5c31\u8be5\u89e3\u51b3\u7684\uff0c\u4e0d\u8be5\u7559\u7ed9\u552e\u540e\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u7684\u505a\u6cd5\uff1a\u4e3b\u673a\u4e0e\u672b\u7aef\u4f18\u5148\u7528\u540c\u4e00\u5957\u63a7\u5236\u903b\u8f91\u2014\u2014\u540c\u54c1\u724c\u7684\u6c34\u529b\u6a21\u5757\u3001\u7ebf\u63a7\u5668\u3001\u96c6\u4e2d\u63a7\u5236\u5668\uff1b\u786e\u5b9e\u8981\u6df7\u7684\u65f6\u5019\uff0c\u7528\u80fd\u8bfb\u5168\u53c2\u6570\u7684\u96c6\u4e2d\u63a7\u5236\u5668\u628a\u8054\u52a8\u70b9\u63a5\u4e0a\uff0c\u5e76\u4e14\u5728\u5408\u540c\u91cc\u628a\u8303\u56f4\u5199\u6e05\u695a\uff1a\u54ea\u4e9b\u8054\u52a8\u6211\u4eec\u8d1f\u8d23\u8c03\u901a\uff0c\u54ea\u4e9b\u5c5e\u4e8e\u5382\u5bb6\u8bbe\u5907\u7684\u81ea\u5e26\u529f\u80fd\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.7 \u591a\u54c1\u724c\u7ec4\u5408\u8fd9\u4ef6\u4e8b\uff0c\u8bf4\u5230\u54ea\u4e00\u6b65\u4e3a\u6b62<\/h3>\n<p class=\"wp-block-paragraph\">\u8fd9\u4e00\u8282\u662f\u7ed9\u9500\u552e\u770b\u7684\uff0c\u4e5f\u662f\u7ed9\u6211\u4eec\u81ea\u5df1\u5212\u7ebf\u7684\u3002\u5ba2\u6237\u4e00\u65e6\u77e5\u9053\u300c\u6c34\u7cfb\u7edf\u4e3b\u673a\u53ef\u4ee5\u6362\u300d\uff0c\u4e0b\u4e00\u4e2a\u95ee\u9898\u4e00\u5b9a\u662f\u300c\u90a3\u80fd\u4e0d\u80fd\u7528\u8fd9\u4e2a\u724c\u5b50\u7684\u4e3b\u673a\u914d\u90a3\u4e2a\u724c\u5b50\u7684\u672b\u7aef\u300d\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5148\u628a\u8fd9\u4ef6\u4e8b\u7684\u540d\u5b57\u8bf4\u6e05\u695a\uff1a<strong>\u70ed\u6e90\u4efb\u610f\u642d\u914d\u3001\u672b\u7aef\u4efb\u610f\u642d\u914d\u3001\u4e2d\u95f4\u53ea\u8981\u6c42\u8054\u52a8\u63a7\u5236\u5bf9\u5f97\u4e0a\uff0c\u8fd9\u5c31\u662f\u591a\u54c1\u724c\u7ec4\u5408<\/strong>\u3002\u5b83\u8ddf\u5730\u6696\u914d\u58c1\u6302\u7089\u662f\u540c\u4e00\u4e2a\u903b\u8f91\u2014\u2014\u5730\u6696\u4e0d\u6311\u70ed\u6e90\uff0c\u6c34\u7cfb\u7edf\u4e5f\u4e0d\u6311\u4e3b\u673a\u3002\u6240\u4ee5\u8fd9\u4e0d\u662f\u67d0\u4e00\u5bb6\u5382\u5546\u7684\u529f\u80fd\uff0c\u662f\u6c34\u8fd9\u6761\u8def\u672c\u8eab\u7684\u5c5e\u6027\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5382\u5bb6\u8d44\u6599\u80cc\u4e66\u7684\u8303\u56f4<\/strong>\uff1a\u540c\u4e00\u7cfb\u5217\u5185\u4e0d\u540c\u529f\u7387\u6df7\u62fc\u3001\u6700\u591a\u56db\u53f0\u5e76\u8054\u3002\u8fd9\u662f\u767d\u7eb8\u9ed1\u5b57\uff0c\u53ef\u4ee5\u8bb2\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7cfb\u7edf\u67b6\u6784\u4e0a\u6210\u7acb\u7684<\/strong>\uff1a\u4e0d\u540c\u54c1\u724c\u7684\u4e3b\u673a\u63a5\u8fdb\u540c\u4e00\u4e2a\u6c34\u73af\u8def\uff0c\u7269\u7406\u4e0a\u53ef\u884c\uff0c\u56e0\u4e3a\u6c34\u662f\u516c\u5171\u63a5\u53e3\u3002\u5de5\u7a0b\u4e0a\u4e0d\u96be\uff0c\u96be\u7684\u662f\u4e09\u4ef6\u4e8b\u2014\u2014\u63a7\u5236\u534f\u8bae\u4e0d\u901a\u3001\u6545\u969c\u8d23\u4efb\u96be\u5206\u3001\u80fd\u6548\u5339\u914d\u8981\u91cd\u65b0\u7b97\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6211\u4eec\u7684\u53e3\u5f84<\/strong>\uff1a\u6c34\u8def\u5c42\u9762\u53ef\u4ee5\u63a5\uff0c\u8fd9\u4e00\u70b9\u4e0d\u542b\u7cca\uff1b\u4f46\u300c\u4e24\u5bb6\u673a\u5668\u914d\u5408\u65e0\u95f4\u300d\u8fd9\u79cd\u8bdd\u4e0d\u8bf4\u3002\u6ca1\u6709\u5382\u5bb6\u7684\u8054\u5408\u80cc\u4e66\uff0c\u8bf4\u4e86\u5c31\u662f\u7ed9\u81ea\u5df1\u57cb\u9690\u60a3\u3002\u5b9e\u9645\u9879\u76ee\u91cc\u6211\u4eec\u80fd\u505a\u5230\u7684\u8fb9\u754c\u662f\uff1a\u4e3b\u673a\u7528\u4e00\u4e2a\u54c1\u724c\u3001\u672b\u7aef\u53ef\u4ee5\u9009\u3001\u63a7\u5236\u7528\u4e00\u4e2a\u5e73\u53f0\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6240\u4ee5\u5ba2\u6237\u95ee\u300c\u6211\u5bb6\u5730\u6696\u4ee5\u540e\u80fd\u4e0d\u80fd\u6362\u4e2a\u724c\u5b50\u7684\u4e3b\u673a\u300d\uff0c\u6b63\u786e\u7684\u56de\u7b54\u662f\uff1a\u80fd\u6362\uff0c\u7ba1\u8def\u4e0d\u7528\u52a8\uff0c\u4f46\u8981\u91cd\u65b0\u6838\u7b97\u6c34\u6e29\u3001\u6d41\u91cf\u548c\u8054\u52a8\u2014\u2014\u8fd9\u4e09\u6837\u914d\u4e0d\u4e0a\uff0c\u6362\u4e86\u4e5f\u4e0d\u8212\u670d\u3002\u8fd9\u53e5\u8bdd\u65e2\u6ca1\u6709\u628a\u8bdd\u8bf4\u5c0f\uff0c\u4e5f\u6ca1\u6709\u628a\u8bdd\u8bf4\u6ee1\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e00\u53e5\u8bdd\u6536\u53e3\uff1a\u6c34\u7cfb\u7edf\u7ed9\u7684\u662f<strong>\u70ed\u6e90\u81ea\u7531\u3001\u672b\u7aef\u81ea\u7531<\/strong>\u8fd9\u4e24\u6837\uff0c\u4ee3\u4ef7\u662f<strong>\u8054\u52a8\u63a7\u5236\u8981\u81ea\u5df1\u89e3\u51b3<\/strong>\u8fd9\u4e00\u6837\u3002\u4e24\u6837\u81ea\u7531\u52a0\u4e00\u6837\u4ee3\u4ef7\uff0c\u5c31\u662f\u591a\u54c1\u724c\u7ec4\u5408\u7684\u5b8c\u6574\u8bf4\u6cd5\u2014\u2014\u4e0d\u795e\u79d8\uff0c\u4e5f\u4e0d\u514d\u8d39\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u56db\u90e8\u5206\uff1a\u7cfb\u7edf\u67b6\u6784\u6df1\u5ea6\u89e3\u6790<\/h2>\n<h3 class=\"wp-block-heading\">4.1 \u4e00\u6b21\u7cfb\u7edf vs \u4e8c\u6b21\u7cfb\u7edf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u4e00\u6b21\u7cfb\u7edf\uff08\u65e0\u6c34\u7bb1\uff0c\u5168\u53d8\u9891\uff09<\/strong><\/td>\n<td><strong>\u4e8c\u6b21\u7cfb\u7edf\uff08\u6709\u6c34\u7bb1\uff0c\u53cc\u6cf5\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7cfb\u7edf\u7ed3\u6784<\/strong><\/td>\n<td>\u4e3b\u673a\u53d8\u9891\u6cf5\u76f4\u8fde\u672b\u7aef<\/td>\n<td>\u4e3b\u673a\u2192\u6c34\u7bb1\u2192\u4e8c\u6b21\u4fa7\u6c34\u6cf5\u2192\u672b\u7aef<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u6cf5\u72b6\u6001<\/strong><\/td>\n<td>\u53d8\u9891\u6cf5\u81ea\u9002\u5e94\u53d8\u6d41\u91cf<\/td>\n<td>\u4e3b\u673a\u4fa7\u5b9a\u6d41\u91cf\uff0c\u4e8c\u6b21\u4fa7\u53d8\u6d41\u91cf<\/td>\n<\/tr>\n<tr>\n<td><strong>\u53d8\u9891\u6280\u672f\u5229\u7528\u7387<\/strong><\/td>\n<td><strong>\u5145\u5206\u53d1\u6325<\/strong><\/td>\n<td><strong>\u4e3b\u673a\u4fa7\u53d8\u9891\u95f2\u7f6e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7f13\u51b2\u6c34\u7bb1<\/strong><\/td>\n<td>\u7cfb\u7edf\u6c34\u91cf\u8fbe\u6807\u65f6<strong>\u4e0d\u9700\u8981<\/strong><\/td>\n<td>\u6807\u914d\uff0c\u4e14\u5e38\u88ab\u6ee5\u7528<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7cfb\u7edf\u80fd\u8017<\/strong><\/td>\n<td><strong>\u6700\u4f4e<\/strong><\/td>\n<td>\u589e\u52a0\u6c34\u7bb1\u70ed\u635f\u8017+\u4e8c\u6b21\u6cf5\u529f\u8017<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6545\u969c\u98ce\u9669<\/strong><\/td>\n<td><strong>\u6700\u4f4e<\/strong><\/td>\n<td>\u4e2d\u7b49\u81f3\u9ad8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u54cd\u5e94\u901f\u5ea6<\/strong><\/td>\n<td><strong>\u6700\u5feb<\/strong><\/td>\n<td>\u8f83\u6162\uff08\u9700\u5148\u52a0\u70ed\/\u51b7\u5374\u6c34\u7bb1\uff09<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<td><strong>\u7edd\u5927\u591a\u6570\u522b\u5885\u3001\u5927\u5e73\u5c42<\/strong><\/td>\n<td>\u672b\u7aef\u6781\u591a(&gt;15\u53f0)\u3001\u7ba1\u8def\u6781\u957f(&gt;200m)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6280\u672f\u8bba\u8bc1<\/strong>\uff1a\u65e5\u7cfb\u5728\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u4e2d\u79ef\u7d2f\u7684<strong>\u4e00\u6b21\u7cfb\u7edf\u5168\u53d8\u9891\u7684\u63a7\u5236\u65b9\u5f0f<\/strong>\uff0c\u5728\u6c34\u7cfb\u7edf\u4e2d\u540c\u6837\u9002\u7528\u3002\u7f13\u51b2\u6c34\u7bb1\u7684\u4ecb\u5165\u53cd\u800c\u5272\u88c2\u4e86\u8fd9\u4e00\u5b8c\u6574\u7684\u63a7\u5236\u903b\u8f91\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u58c1\u6302\u7089\u4e3a\u4f55\u6bd4\u7a7a\u6c14\u80fd\u66f4\u9700\u8981\u4e8c\u6b21\u7cfb\u7edf<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u7a7a\u6c14\u80fd\uff08\u5168\u53d8\u9891\uff09<\/strong><\/td>\n<td><strong>\u58c1\u6302\u7089\uff08\u5b9a\u9891\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u529f\u7387<\/td>\n<td>12.5kW\uff08\u5339\u914d100\u33a1\uff09<\/td>\n<td>24kW\uff08\u4e25\u91cd\u8fc7\u5269\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u7f6e\u6c34\u6cf5<\/td>\n<td>\u53d8\u9891\u6cf5\uff0c\u5382\u5bb6\u5339\u914d<\/td>\n<td>\u5b9a\u989115-6\u6cf5\uff0c\u5b9e\u9645700-900L\/h<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u7ba1\u7ba1\u5f84<\/td>\n<td>\u226540mm<\/td>\n<td>\u5e02\u573a\u901a\u914d25mm<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u67b6\u6784<\/td>\n<td>\u4e00\u6b21\u7cfb\u7edf<\/td>\n<td><strong>\u9700\u4e8c\u6b21\u7cfb\u7edf<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">4.2 \u7f13\u51b2\u6c34\u7bb1\u7684\u771f\u76f8\u4e0e\u8bef\u533a<\/h3>\n<p class=\"wp-block-paragraph\"><strong>2.2.1 \u7f13\u51b2\u6c34\u7bb1\u7684\u771f\u5b9e\u4f5c\u7528<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u6982\u62ec<\/strong>\uff1a\u7f13\u51b2\u6c34\u7bb1\u53ea\u505a\u4e00\u4ef6\u4e8b\u2014\u2014<strong>\u589e\u52a0\u7cfb\u7edf\u91cc\u7684\u603b\u6c34\u91cf<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5f00\u5229\u4ea7\u54c1\u624b\u518c\u7ed9\u51fa\u7684\u6700\u5c0f\u6c34\u5bb9\u91cf\u53c2\u8003\u7b97\u6cd5<\/strong>\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6700\u5c0f\u6c34\u5bb9\u91cf\uff08\u5347\uff09= \u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf\uff08kW\uff09\u00d7 N<\/strong><\/p>\n<\/blockquote>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5e94\u7528\u7c7b\u578b<\/strong><\/td>\n<td><strong>N\u503c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u7a7a\u8c03\uff08\u8212\u9002\u6027\u7a7a\u8c03\uff09<\/td>\n<td><strong>3.25 L\/kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5de5\u4e1a\u5de5\u827a\u51b7\u5374<\/td>\n<td>6.5 L\/kW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u8fd9\u91cc\u8981\u8bf4\u51c6\u4e00\u53e5\uff1a<strong>3.25 L\/kW \u662f\u5f00\u5229\u4ea7\u54c1\u624b\u518c\u91cc\u8212\u9002\u6027\u7a7a\u8c03\u7684\u53c2\u8003\u7ecf\u9a8c\u7cfb\u6570\uff0c\u6765\u81ea\u5382\u5bb6\u5de5\u7a0b\u624b\u518c\uff0c\u4e0d\u662f\u5f3a\u5236\u56fd\u6807\uff0c\u4e5f\u4e0d\u662f\u884c\u4e1a\u5f3a\u5236\u6267\u884c\u7684\u8ba1\u7b97\u516c\u5f0f<\/strong>\uff08\u5de5\u4e1a\u5de5\u827a\u51b7\u5374\u53e6\u6709 6.5 L\/kW \u4e00\u6863\uff09\u3002\u5b83\u7684\u7528\u9014\u662f\u4f30\u7b97\u300c\u7cfb\u7edf\u91cc\u7684\u6c34\u591f\u4e0d\u591f\u300d\uff0c\u4e0d\u662f\u5224\u300c\u5fc5\u987b\u88c5\u591a\u5927\u7684\u6c34\u7bb1\u300d\u3002\u67d0\u4e2a\u5177\u4f53\u9879\u76ee\u8981\u4e0d\u8981\u8865\u6c34\u7bb1\u3001\u8865\u591a\u5927\uff0c\u5f97\u6309\u73b0\u573a\u6c34\u529b\u8ba1\u7b97\u5b9a\u2014\u2014\u7ba1\u5f84\u3001\u7ba1\u957f\u3001\u672b\u7aef\u53f0\u6570\u3001\u5730\u6696\u76d8\u7ba1\u91cc\u5b58\u7684\u6c34\u90fd\u8981\u7b97\u8fdb\u53bb\uff0c\u8fd8\u5f97\u770b\u4e3b\u673a\u81ea\u5df1\u7684\u6700\u5c0f\u6c34\u5bb9\u91cf\u8981\u6c42\uff08\u65e5\u7acb\u53e3\u5f84\u662f 2 L\/kW\uff0c\u6bd4\u5f00\u5229\u8fd9\u4e00\u6863\u4f4e\uff09\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5382\u5bb6\u624b\u518c\u91cc\u7684\u7cfb\u6570\u662f\u9009\u578b\u7684\u8d77\u70b9\uff0c\u4e0d\u662f\u5224\u51b3\u4e66\u3002\u9047\u5230\u7b97\u4e0b\u6765\u521a\u597d\u5728\u4e34\u754c\u503c\u9644\u8fd1\u7684\u6237\u578b\uff0c\u5b81\u53ef\u628a\u4e3b\u7ba1\u7ba1\u5f84\u653e\u5927\u4e00\u6863\uff0c\u4e5f\u6bd4\u786c\u52a0\u4e00\u4e2a\u6c34\u7bb1\u5212\u7b97\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5f00\u5229\u5b98\u65b9\u7ed3\u8bba<\/strong>\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\"\u5728\u5927\u591a\u6570\u8212\u9002\u6027\u7a7a\u8c03\u5e94\u7528\u4e2d\uff0c\u8fd9\u4e00\u7279\u6027\uff08\u53d8\u9891\u6280\u672f\uff09\u4f7f\u5f97\u7f13\u51b2\u6c34\u7bb1\u53d8\u5f97\u4e0d\u5fc5\u8981\u3002\"<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>2.2.2 \u5e38\u89c1\u9519\u8bef\u8ba4\u77e5\u4e0e\u771f\u76f8<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9519\u8bef\u8ba4\u77e5<\/strong><\/td>\n<td><strong>\u771f\u76f8<\/strong><\/td>\n<td><strong>\u7269\u7406\u539f\u7406<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u7bb1\u80fd\u7a33\u5b9a\u4e3b\u673a\u8fd0\u884c<\/td>\n<td>\u274c<\/td>\n<td>\u7a33\u5b9a\u6027\u53d6\u51b3\u4e8e\u7ba1\u5f84\u8bbe\u8ba1<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u7bb1\u80fd\u6539\u5584\u6362\u70ed\u6548\u7387<\/td>\n<td>\u274c<\/td>\n<td>\u6c34\u7bb1\u4e0d\u53c2\u4e0e\u6362\u70ed\u5668\u5185\u90e8\u70ed\u4ea4\u6362<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u7bb1\u80fd\u9632\u51bb<\/td>\n<td>\u274c<\/td>\n<td>\u9632\u51bb\u9760\u7cfb\u7edf\u8bbe\u7f6e\u548c\u51ac\u5b63\u6392\u7a7a<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u7bb1\u8d8a\u5927\u8d8a\u597d<\/td>\n<td>\u274c<\/td>\n<td>\u6c34\u7bb1\u8fc7\u5927\u4f1a\u589e\u52a0\u70ed\u60ef\u6027<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.2.3 \u84c4\u70ed\u6c34\u7bb1\u7684\u5386\u53f2\u529f\u80fd\u6f14\u53d8<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9636\u6bb5<\/strong><\/td>\n<td><strong>\u529f\u80fd<\/strong><\/td>\n<td><strong>\u5fc5\u8981\u6027<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u65e9\u671f\u6c34\u673a\uff08\u98ce\u76d8\u91c7\u6696\uff09<\/strong><\/td>\n<td>\u5916\u673a\u9664\u971c\u65f6\u91ca\u653e\u70ed\u91cf<\/td>\n<td>\u5fc5\u8981<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e24\u8054\u4f9b\u521d\u671f<\/strong><\/td>\n<td>\u5ef6\u7eed\u65e9\u671f\u8bbe\u8ba1\u60ef\u6027<\/td>\n<td>\u4e0d\u5fc5\u8981<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e24\u8054\u4f9b+\u5730\u6696\u65f6\u671f<\/strong><\/td>\n<td>\u5730\u6696\u56de\u586b\u5c42\u5df2\u5177\u5907\u66f4\u5f3a\u84c4\u70ed\u80fd\u529b<\/td>\n<td><strong>\u5b8c\u5168\u5197\u4f59<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.2.4 \u5730\u6696\u84c4\u70ed\u80fd\u529b\u7cbe\u786e\u8ba1\u7b97<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u7269\u7406\u516c\u5f0f\uff1a\u7b49\u6548\u6c34\u91cf = m_\u6df7\u51dd\u571f \u00d7 (C_\u6df7\u51dd\u571f \/ C_\u6c34)<\/p>\n<ul class=\"wp-block-list\">\n<li>\u6df7\u51dd\u571f\u5bc6\u5ea6 \u03c1 \u2248 2000 kg\/m\u00b3<\/li>\n<li>\u6df7\u51dd\u571f\u6bd4\u70ed\u5bb9 C_\u6df7\u51dd\u571f \u2248 0.88 kJ\/(kg\u00b7\u2103)<\/li>\n<li>100\u33a1\u9762\u79ef \u00d7 0.05m\u539a\u5ea6 = 5 m\u00b3 \u2192 10,000 kg<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">\u7b49\u6548\u6c34\u91cf = 10,000 \u00d7 (0.88 \/ 4.2) \u2248 <strong>2,100\u5347<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u5e38\u89c4\u7f13\u51b2\u6c34\u7bb1\uff0860-150L\uff09\u4ec5\u662f\u5730\u6696\u84c4\u70ed\u80fd\u529b\u7684<strong>3%-7%<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>2.2.5 \u6c34\u7bb1\u8fc7\u5927\u7684\u4e09\u5927\u5371\u5bb3\uff08\u70ed\u60ef\u6027\u539f\u7406\uff09<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5371\u5bb3<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u80fd\u8017\u589e\u52a0<\/strong><\/td>\n<td>\u4e3b\u673a\u9700\u591a\u8fd0\u884c\u6765\u7ef4\u6301\u6c34\u7bb1\u6e29\u5ea6<\/td>\n<\/tr>\n<tr>\n<td><strong>\u54cd\u5e94\u53d8\u6162<\/strong><\/td>\n<td>\u5f00\u673a\u540e\u8981\u5148\u628a\u6c34\u7bb1\u91cc\u7684\u6c34\u52a0\u70ed\/\u51b7\u5374<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6545\u969c\u98ce\u9669<\/strong><\/td>\n<td>\u591a\u4e00\u4e2a\u6c34\u7bb1\u5c31\u591a\u4e00\u4e2a\u8fde\u63a5\u70b9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.2.6 \u6c34\u7bb1\u5185\u90e8\u6321\u677f\u4e0e\u8fde\u63a5\u65b9\u5f0f\uff08\u5f00\u5229\u89c4\u8303\uff09<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8981\u6c42<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5fc5\u987b\u5e26\u5185\u90e8\u6321\u677f<\/strong><\/td>\n<td>\u786e\u4fdd\u6c34\u6d41\u5145\u5206\u6df7\u5408\uff0c\u907f\u514d\u6e29\u5ea6\u5206\u5c42<\/td>\n<\/tr>\n<tr>\n<td><strong>\u8fdb\u51fa\u6c34\u53e3\u5206\u5c45\u4e24\u4fa7<\/strong><\/td>\n<td>\u907f\u514d\u6c34\u77ed\u8def\uff0c\u5145\u5206\u5229\u7528\u6c34\u7bb1\u5bb9\u79ef<\/td>\n<\/tr>\n<tr>\n<td>\u274c \u8fdb\u51fa\u6c34\u53e3\u540c\u4fa7<\/td>\n<td>\u6c34\u6d41\u76f4\u63a5\u4ece\u8fdb\u53e3\u5230\u51fa\u53e3\uff0c\u6c34\u7bb1\u65e0\u6548<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>2.2.7 \u6c7d\u8f66\u6cb9\u7bb1\u6bd4\u55bb\uff08\u5ba2\u6237\u6c9f\u901a\u7248\uff09<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u52a0\u6c34\u7bb1\u5c31\u50cf\u7ed9\u6c7d\u8f66\u52a0\u4e2a\u8d85\u5927\u526f\u6cb9\u7bb1\u3002\u60a8\u672c\u6765\u52a050\u5347\u6cb9\u80fd\u8dd1500\u516c\u91cc\uff0c\u73b0\u5728\u975e\u8981\u52a0\u4e2a100\u5347\u7684\u526f\u6cb9\u7bb1\u3002\u8f66\u91cd\u4e86\u3001\u6cb9\u8017\u9ad8\u4e86\u3001\u94b1\u591a\u82b1\u4e86\uff0c\u4f46\u60a8\u6bcf\u5929\u8fd8\u662f\u53ea\u8dd1\u90a3\u4e48\u8fdc\u3002\u591a\u82b1\u7684\u94b1\uff0c\u5168\u6d6a\u8d39\u4e86\u3002\u201d<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">4.3 \u5168\u53d8\u9891\u7cfb\u7edf\u7684\u6838\u5fc3\u4f18\u52bf<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u2705 \u53d8\u9891\u538b\u7f29\u673a\uff08\u6309\u9700\u8f93\u51fa\u51b7\u70ed\u91cf\uff09<\/li>\n<li>\u2705 \u5185\u7f6e\u53d8\u9891\u6c34\u6cf5\uff08\u6309\u9700\u8c03\u8282\u6c34\u6d41\u91cf\uff09<\/li>\n<li>\u2705 \u5c01\u88c5\u5f0f\u5bb6\u7528\u5185\u673a\uff08\u98ce\u76d8\uff09<\/li>\n<li>\u2705 \u8054\u52a8\u63a7\u5236\u903b\u8f91<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u4f18\u52bf<\/strong>\uff1a\u8fd0\u884c\u7a33\u5b9a\u3001\u6545\u969c\u7387\u4f4e\u3001\u5bff\u547d\u957f\u3001\u4e0d\u9700\u8981\u989d\u5916\u52a0\u88c5\u6c34\u6cf5\u6c34\u7bb1\u3001\u4e0d\u4f1a\u51fa\u73b0\u201c\u5355\u5f00\u62a5\u8b66\u201d\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e94\u90e8\u5206\uff1a\u5e38\u89c1\u6545\u969c\u4e0e\u5e02\u573a\u4e71\u8c61<\/h2>\n<h3 class=\"wp-block-heading\">5.1 \u6c34\u7cfb\u7edf\u6545\u969c\u6c47\u603b<\/h3>\n<p class=\"wp-block-paragraph\"><strong>3.1.1 \u7cfb\u7edf\u4fa7\u6545\u969c<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6545\u969c\u73b0\u8c61<\/strong><\/td>\n<td><strong>\u539f\u56e0\u5206\u6790<\/strong><\/td>\n<td><strong>\u6392\u9664\u65b9\u6cd5<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6392\u6c14\u538b\u529b\u8fc7\u9ad8<\/strong><\/td>\n<td>\u51b7\u51dd\u5668\u8fdb\u6c34\u6e29\u5ea6\u8fc7\u9ad8\/\u6d41\u91cf\u4e0d\u8db3<\/td>\n<td>\u68c0\u67e5\u6c34\u8fc7\u6ee4\u5668\u3001\u6392\u7a7a\u6c14<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6362\u70ed\u5668\u51bb\u88c2<\/strong><\/td>\n<td>\u6d41\u901f\u8fc7\u6162\u5236\u51b7\u7ed3\u51b0\uff1b\u6d41\u91cf\u5f00\u5173\u88ab\u77ed\u63a5<\/td>\n<td>\u786e\u4fdd\u6700\u5c0f\u6c34\u6d41\u91cf\uff1b\u4e25\u7981\u53d6\u6d88\u6d41\u91cf\u4fdd\u62a4<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u6d41\u6545\u969c\u62a5\u8b66<\/strong><\/td>\n<td>\u6d41\u91cf\u8fc7\u5927\u6216\u8fc7\u5c0f\uff1b\u6c34\u6cf5\u9009\u578b\u4e0d\u5f53<\/td>\n<td>\u68c0\u67e5\u6c34\u6cf5\u5339\u914d\uff1b\u6e05\u6d17\u8fc7\u6ee4\u5668<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>3.1.2 \u6bd4\u4f8b\u8c03\u8282\u4e0e\u5b9a\u9891\u6cf5\u7684\u6c34\u9524\u95ee\u9898<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong>\u73b0\u8c61<\/strong>\uff1a\u5f53\u7cfb\u7edf\u91c7\u7528\u5b9a\u9891\u6c34\u6cf5\uff0c\u672b\u7aef\u4f7f\u7528\u6bd4\u4f8b\u8c03\u8282\u9600\u65f6\uff0c\u90e8\u5206\u9600\u95e8\u5173\u95ed\u540e\uff0c\u7ba1\u9053\u51fa\u73b0\u566a\u97f3\u3001\u5578\u53eb\u3001\u9707\u52a8\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u539f\u7406<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5b9a\u9891\u6c34\u6cf5\u8f6c\u901f\u56fa\u5b9a\uff0c\u672b\u7aef\u9600\u95e8\u5173\u5c0f \u2192 \u7ba1\u8def\u963b\u529b\u589e\u5927 \u2192 \u6c34\u6cf5\u5de5\u4f5c\u70b9\u5de6\u79fb \u2192 \u626c\u7a0b\u5347\u9ad8<\/li>\n<li>\u9ad8\u626c\u7a0b\u6c34\u6d41\u51b2\u51fb\u534a\u95ed\u9600\u95e8\uff0c\u4ea7\u751f\u201c\u6c34\u9524\u6548\u5e94\u201d\u2014\u2014\u538b\u529b\u6ce2\u5728\u7ba1\u9053\u5185\u5f80\u590d\u4f20\u64ad\uff0c\u4e0e\u7ba1\u58c1\u6469\u64e6\u4ea7\u751f\u632f\u52a8\u548c\u5578\u53eb<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u7c7b\u6bd4<\/strong>\uff1a\u5c31\u50cf\u5927\u98ce\u5929\u628a\u7a97\u6237\u5f00\u4e00\u6761\u5c0f\u7f1d\uff0c\u98ce\u94bb\u8fdb\u6765\u4f1a\u4ea7\u751f\u9707\u52a8\u548c\u5578\u53eb\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u89e3\u51b3\u65b9\u6848<\/strong>\uff1a\u6bd4\u4f8b\u8c03\u8282\u7cfb\u7edf<strong>\u5fc5\u987b\u642d\u914d\u5168\u53d8\u9891\u81ea\u9002\u5e94\u6c34\u6cf5<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>3.1.3 \u63a7\u5236\u4fa7\u6545\u969c<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6545\u969c\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u95ee\u9898\u63cf\u8ff0<\/strong><\/td>\n<td><strong>\u5f71\u54cd<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u6cf5\u65e0\u8054\u52a8<\/strong><\/td>\n<td>\u6c34\u6cf524\u5c0f\u65f6\u6301\u7eed\u8fd0\u884c<\/td>\n<td>\u80fd\u8017\u6d6a\u8d39\u4e25\u91cd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6d41\u91cf\u5f00\u5173\u88ab\u53d6\u6d88<\/strong><\/td>\n<td>\u4eba\u4e3a\u53d6\u6d88\u6c34\u6d41\u4fdd\u62a4<\/td>\n<td>\u6362\u70ed\u5668\u51bb\u88c2\u98ce\u9669\u5267\u589e<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9891\u7e41\u542f\u505c<\/strong><\/td>\n<td>\u8d1f\u8377\u5339\u914d\u4e0d\u5f53<\/td>\n<td>\u538b\u7f29\u673a\u5bff\u547d\u7f29\u77ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>3.1.4 \u63a7\u5236\u8054\u52a8\u4e09\u8981\u7d20<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u8981\u7d20<\/strong><\/td>\n<td><strong>\u63a7\u5236\u903b\u8f91<\/strong><\/td>\n<td><strong>\u6b63\u786e\u505a\u6cd5<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e3b\u673a<\/strong><\/td>\n<td>\u6309\u6c34\u6e29\u542f\u505c<\/td>\n<td>\u63a5\u6536\u5ba4\u6e29\u4fe1\u53f7\uff0c\u6309\u9700\u542f\u505c<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u6cf5<\/strong><\/td>\n<td>\u6301\u7eed\u8fd0\u884c\u68c0\u6d4b\u6c34\u6e29<\/td>\n<td>\u5ba4\u6e29\u8fbe\u6807\u540e\u505c\u673a<\/td>\n<\/tr>\n<tr>\n<td><strong>\u672b\u7aef\u6e29\u63a7\u5668<\/strong><\/td>\n<td>\u6309\u5ba4\u6e29\u5f00\u5173\u9600\u95e8<\/td>\n<td>\u8054\u52a8\u4e3b\u673a\u548c\u6c34\u6cf5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6b63\u786e\u8054\u52a8\u903b\u8f91<\/strong>\uff1a<\/p>\n<pre class=\"wp-block-code\"><code>\u5ba4\u6e29\u4f4e\u4e8e\u8bbe\u5b9a \u2192 \u8054\u52a8\u542f\u52a8\u6c34\u6cf5 \u2192 \u8054\u52a8\u542f\u52a8\u4e3b\u673a \u2192 \u5ba4\u6e29\u8fbe\u6807 \u2192 \u8054\u52a8\u505c\u673a\n<\/code><\/pre>\n<p class=\"wp-block-paragraph\"><strong>3.1.5 \u65e5\u7acb\u5168\u8054\u52a8\u63a7\u5236\u6280\u672f\uff08\u4e94\u6052\u7cfb\u7edf\u57fa\u7840\uff09<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u4ee5\u5185\u673a\u4e3a\u6838\u5fc3\u611f\u77e5\u8282\u70b9\uff0c\u8054\u52a8\u5168\u5c4b\u8bbe\u5907\uff1a\u5185\u673a\u5fae\u98ce\u5faa\u73af\u5b9e\u65f6\u68c0\u6d4b\u6e29\u6e7f\u5ea6\u3001PM2.5\u3001CO\u2082\uff0c\u5ba4\u6e29\u8fbe\u6807\u2192\u5173\u95ed\u6c34\u6cf5\u548c\u5916\u673a\uff0cCO\u2082\u8d85\u6807\u2192\u542f\u52a8\u65b0\u98ce\u3002\u5b9e\u73b0\u201c\u4e00\u673a\u611f\u77e5\u3001\u5168\u5c4b\u54cd\u5e94\u201d\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>3.1.6 \u5185\u673a\u4fa7\u6545\u969c<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6545\u969c\u73b0\u8c61<\/strong><\/td>\n<td><strong>\u539f\u56e0\u5206\u6790<\/strong><\/td>\n<td><strong>\u540e\u679c<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ed3\u9732\u6ef4\u6c34\u6ce1\u9876<\/strong><\/td>\n<td>\u534a\u5305\u5f0f\u98ce\u76d8\u4fdd\u6e29\u4e0d\u826f<\/td>\n<td>\u51b7\u51dd\u6c34\u6ef4\u843d\u540a\u9876<\/td>\n<\/tr>\n<tr>\n<td><strong>\u63a5\u6c34\u76d8\u79ef\u5c18\u53d1\u9709<\/strong><\/td>\n<td>\u81ea\u7136\u6392\u6c34\u5761\u5ea6\u79ef\u5c18<\/td>\n<td>\u6210\u4e3a\u75c5\u6e90\u4f53<\/td>\n<\/tr>\n<tr>\n<td><strong>\u566a\u97f3\u8fc7\u5927<\/strong><\/td>\n<td>\u5b9a\u9891\u4ea4\u6d41\u7535\u673a<\/td>\n<td>\u5f71\u54cd\u8212\u9002\u5ea6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>3.1.7 \u534a\u5305\u5f0f\u98ce\u76d8 vs \u5168\u5305\u5f0f\u98ce\u76d8<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u534a\u5305\u5f0f\u98ce\u76d8<\/strong><\/td>\n<td><strong>\u5168\u5305\u5f0f\/\u5c01\u88c5\u5f0f\u98ce\u76d8<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7ed3\u6784<\/strong><\/td>\n<td>\u63a5\u6c34\u76d8\u5916\u7f6e<\/td>\n<td>\u4e00\u4f53\u5c01\u88c5<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6392\u6c34\u65b9\u5f0f<\/strong><\/td>\n<td>\u91cd\u529b\u81ea\u7136\u5761\u5ea6<\/td>\n<td>\u5185\u7f6e\u63d0\u5347\u6cf5<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4fdd\u6e29<\/strong><\/td>\n<td>\u7c97\u7cd9\uff0c\u6613\u7ed3\u9732<\/td>\n<td>\u6574\u4f53\u4fdd\u6e29<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u673a<\/strong><\/td>\n<td>\u5b9a\u9891\u4ea4\u6d41\uff0c\u566a\u97f3\u5927<\/td>\n<td>\u76f4\u6d41\u53d8\u9891\uff0c\u9759\u97f3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6210\u672c<\/strong><\/td>\n<td>\u4f4e<\/td>\n<td>\u9ad8\uff08\u5dee\u4ef7\u53ef\u8fbe2000\u5143\u4ee5\u4e0a\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u8fd9\u5f20\u8868\u6bd4\u8f83\u7684\u662f<strong>\u5bb6\u7528\u4f4f\u5b85\u540a\u9876\u5185<\/strong>\u7684\u4e24\u79cd\u505a\u6cd5\u3002\u8981\u8bf4\u6e05\u695a\u7684\u662f\uff1a\u534a\u5305\u5f0f\u98ce\u76d8\u5e76\u4e0d\u662f\u5b8c\u5168\u4e0d\u80fd\u7528\u2014\u2014\u90e8\u5206\u5546\u4e1a\u7a7a\u95f4\u3001\u660e\u88c5\u573a\u5408\u3001\u673a\u623f\u548c\u5de5\u4e1a\u5382\u623f\u7167\u6837\u5728\u7528\uff0c\u63a5\u6c34\u76d8\u5916\u7f6e\u672c\u6765\u5c31\u662f\u4e00\u4e2a\u6210\u719f\u505a\u6cd5\u3002\u5b83\u7684\u77ed\u677f\u96c6\u4e2d\u5728\u5bb6\u7528\u4f4f\u5b85\u8fd9\u4e2a\u573a\u666f\uff1a\u540a\u9876\u91cc\u7a7a\u95f4\u7a84\u3001\u68c0\u4fee\u53e3\u5c0f\u3001\u51b7\u51dd\u6c34\u9760\u81ea\u7136\u5761\u5ea6\u6392\u3001\u4fdd\u6e29\u5c42\u505a\u5f97\u7cd9\uff0c\u4e00\u65e6\u7ed3\u9732\u5c31\u662f\u6ce1\u9876\uff0c\u63a5\u6c34\u76d8\u79ef\u5c18\u53d1\u9709\u4e5f\u770b\u4e0d\u5230\u3002\u6240\u4ee5\u7ed3\u8bba\u662f<strong>\u4f4f\u5b85\u540a\u9876\u5185\u4e0d\u63a8\u8350<\/strong>\uff0c\u4e0d\u662f\u300c\u534a\u5305\u5f0f\u4e00\u5f8b\u4e0d\u80fd\u7528\u300d\u3002<\/p>\n<h3 class=\"wp-block-heading\">5.2 \u5f53\u524d\u5e02\u573a\u56db\u5927\u4e71\u8c61<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u4e71\u8c61\u4e00\uff1a\u65b9\u6848\u5012\u9000<\/strong>\u2014\u2014\u5c06\u201c\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u201d\u5f3a\u884c\u8bbe\u8ba1\u4e3a\u201c\u4e8c\u6b21\u7cfb\u7edf+\u7f13\u51b2\u6c34\u7bb1\u201d<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e71\u8c61\u4e8c\uff1a\u786c\u4ef6\u51cf\u914d<\/strong>\u2014\u2014\u5c06\u5168\u5305\u5f0f\u98ce\u76d8\u5077\u6362\u6210\u534a\u5305\u5f0f\u98ce\u76d8\uff0c\u5355\u53f0\u5dee\u4ef72000\u5143\u4ee5\u4e0a<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e71\u8c61\u4e09\uff1a\u63a7\u5236\u7f3a\u5931<\/strong>\u2014\u2014\u4e0d\u505a\u6c34\u6cf5\u8054\u52a8\uff0c\u6c34\u6cf524\u5c0f\u65f6\u8fd0\u8f6c<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e71\u8c61\u56db\uff1a\u8425\u9500\u8bef\u5bfc<\/strong>\u2014\u2014\u6253\u7740\u201c\u7f8e\u7cfb\u4e13\u4e1a\u6c34\u673a\u201d\u65d7\u53f7\uff0c\u63a9\u76d6\u65e5\u7cfb\u6280\u672f\u5185\u6838<\/p>\n<p class=\"wp-block-paragraph\"><strong>3.2.1 \u4e3a\u4ec0\u4e48\u5546\u5bb6\u7231\u63a8\u201c\u52a0\u6c34\u7bb1\u3001\u4e8c\u6b21\u7cfb\u7edf\u201d\uff1f<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u539f\u56e0<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u63a9\u76d6\u8bbe\u8ba1\u7f3a\u9677<\/td>\n<td>\u8bbe\u8ba1\u5e08\u4e0d\u4f1a\u7b97\u7ba1\u5f84\uff0c\u52a0\u6c34\u7bb1\u80fd\u8ba9\u7cfb\u7edf\u201c\u52c9\u5f3a\u80fd\u7528\u201d<\/td>\n<\/tr>\n<tr>\n<td>\u591a\u5356\u8bbe\u5907\u591a\u8d5a\u94b1<\/td>\n<td>\u7f13\u51b2\u6c34\u7bb1+\u4e8c\u6b21\u6cf5+\u8f85\u6750 \u2248 \u591a\u65366000-8000\u5143<\/td>\n<\/tr>\n<tr>\n<td>\u8ddf\u98ce\u4f20\u64ad\u9519\u8bef<\/td>\n<td>\u7f51\u7ea2\u3001\u535a\u4e3b\u4e0d\u61c2\u539f\u7406\uff0c\u770b\u522b\u4eba\u8bf4\u597d\u5c31\u8ddf\u7740\u8bf4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u516d\u90e8\u5206\uff1a\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u6307\u5357<\/h2>\n<h3 class=\"wp-block-heading\">6.1 PERT\u7ba1<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u7279\u70b9<\/strong>\uff1a\u6563\u70ed\u6027\u3001\u67d4\u97e7\u6027\u3001\u53ef\u56de\u6536\u6027\u4f18\uff0c\u662f\u5730\u6696\u76d8\u7ba1\u7684\u6700\u4f73\u9009\u62e9<\/li>\n<li><strong>\u7b56\u7565<\/strong>\uff1a\u4e24\u8054\u4f9b\u4f9b\u6c34\u226455\u2103\uff0c\u9ad8\u6e29\u98ce\u9669\u4e3a\u96f6\uff0c\u53ef<strong>\u65e0\u8111\u9009\u62e9PERT<\/strong><\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">6.2 PE-Xa\u7ba1<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u7279\u70b9<\/strong>\uff1a\u8010\u9ad8\u6e29\u9ad8\u538b\uff0c\u5177\u6709\u201c\u8bb0\u5fc6\u529f\u80fd\u201d<\/li>\n<li><strong>\u98ce\u9669<\/strong>\uff1a\u5316\u5b66\u4ea4\u8054\u751f\u4ea7\u8fc7\u7a0b\u4e0d\u8fbe\u6807\u5219\u4ea4\u8054\u201c\u5931\u8054\u201d\uff1b\u4f4e\u4ef7\u4ea7\u54c1\u591a\u4e3a\u56de\u6536\u6599<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">6.3 \u94dd\u5851\u590d\u5408\u7ba1<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u7279\u70b9<\/strong>\uff1a\u67d4\u6027\u5f3a\uff0c\u53ef\u65e0\u63a5\u5934\u9690\u853d\u5b89\u88c5\uff1b\u94dd\u5c42\u5929\u7136\u7edd\u6c27<\/li>\n<li><strong>\u98ce\u9669<\/strong>\uff1a\u4f4e\u4ef7\u4ea7\u54c1\u5b58\u5728\u7ba1\u5f84\u9677\u9631\uff0816\u7ba1\u4ee320\u7ba1\uff09\uff1b32\u4ee5\u4e0a\u67d4\u6027\u6d88\u5931<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">6.4 PPR\u7ba1\u6750\u58c1\u539a\u89c4\u683c<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ba1\u7cfb\u5217(S\u503c)<\/strong><\/td>\n<td><strong>\u58c1\u539a\u7b49\u7ea7<\/strong><\/td>\n<td><strong>\u4e24\u8054\u4f9b\u9002\u7528\u6027<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>S5<\/strong><\/td>\n<td>\u6700\u8584<\/td>\n<td>\u274c \u4e25\u7981\u7528\u4e8e\u7a7a\u8c03\u4e3b\u7ba1<\/td>\n<\/tr>\n<tr>\n<td><strong>S4<\/strong><\/td>\n<td>\u4e2d\u7b49<\/td>\n<td>\u26a0\ufe0f \u9700\u6821\u6838\u6d41\u91cf<\/td>\n<\/tr>\n<tr>\n<td><strong>S3.2<\/strong><\/td>\n<td><strong>\u6700\u539a<\/strong><\/td>\n<td>\u2705 <strong>\u4e24\u8054\u4f9b\u4e3b\u7ba1\u9053\u9996\u9009<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u5173\u952e\u8bb0\u5fc6\u70b9<\/strong>\uff1a<strong>S\u503c\u8d8a\u5c0f\uff0c\u58c1\u8d8a\u539a<\/strong><\/p>\n<h3 class=\"wp-block-heading\">6.5 \u4f1f\u661fF-PPRCT\u4e13\u4e1a\u6c34\u673a\u7ba1\u9053<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u4f20\u7edfPPR<\/strong><\/td>\n<td><strong>\u4f1f\u661fF-PPRCT<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u57fa\u7840\u6750\u6599<\/td>\n<td>PP-R<\/td>\n<td><strong>PP-RCT<\/strong>\uff08\u8010\u70ed\u589e\u5f3a\u578b\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u8010\u538b\u80fd\u529b<\/td>\n<td>\u57fa\u51c6<\/td>\n<td><strong>\u63d0\u534720%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5185\u622a\u9762\u79ef<\/td>\n<td>\u57fa\u51c6<\/td>\n<td><strong>\u63d0\u534711%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6d41\u91cf\u8868\u73b0<\/td>\n<td>\u57fa\u51c6<\/td>\n<td><strong>\u5e73\u5747\u63d0\u53479%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u5bff\u547d<\/td>\n<td>\u2014<\/td>\n<td><strong>\u7ea650\u5e74<\/strong>\uff0860\u2103\u6761\u4ef6\u4e0b\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">6.6 \u963b\u6c27\u7ba1\u7684\u5fc5\u8981\u6027<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u6c27\u6c14\u6e17\u900f\u7684\u5371\u5bb3<\/strong>\uff1a\u6c34\u57a2\u3001\u7eff\u85fb\u3001\u91d1\u5c5e\u90e8\u4ef6\u6c27\u5316\u8150\u8680<\/li>\n<li><strong>\u5173\u952e\u539f\u5219<\/strong>\uff1a<strong>\u4e00\u534a\u963b\u6c27\u4e00\u534a\u4e0d\u963b\u6c27 = \u767d\u505a<\/strong><\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">6.7 \u7ba1\u5f84-\u6d41\u91cf-\u70ed\u503c\u901f\u67e5\u8868\uff0810\u2103\u6e29\u5dee\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ba1\u5f84<\/strong><\/td>\n<td><strong>\u53c2\u8003\u6d41\u91cf<\/strong><\/td>\n<td><strong>\u53ef\u643a\u5e26\u70ed\u503c<\/strong><\/td>\n<td><strong>\u7ea6\u675f\u6761\u4ef6<\/strong><\/td>\n<\/tr>\n<tr>\n<td>De16<\/td>\n<td>~100 L\/h<\/td>\n<td>~1.2 kW<\/td>\n<td>\u76d8\u7ba1\u2264120m\uff0c\u6d41\u901f\u22640.5m\/s<\/td>\n<\/tr>\n<tr>\n<td>De20<\/td>\n<td>~200 L\/h<\/td>\n<td>~2.3 kW<\/td>\n<td>\u76d8\u7ba1\u2264120m\uff0c\u6d41\u901f\u22640.5m\/s<\/td>\n<\/tr>\n<tr>\n<td>De25<\/td>\n<td>~500 L\/h<\/td>\n<td>~5.8 kW<\/td>\n<td>\u652f\u7ba1\u226450m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td><strong>De32<\/strong><\/td>\n<td><strong>~1,000 L\/h<\/strong><\/td>\n<td><strong>~11.6 kW<\/strong><\/td>\n<td>\u4e3b\u7ba1\u226480m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td><strong>De40<\/strong><\/td>\n<td><strong>~2,000 L\/h<\/strong><\/td>\n<td><strong>~23.2 kW<\/strong><\/td>\n<td>\u4e3b\u7ba1\u2264100m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">6.8 \u201c\u5c0f\u7ba1\u5f84\u66ff\u4ee3\u201d\u9677\u9631<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5e94\u4f7f\u7528<\/strong><\/td>\n<td><strong>\u88ab\u66ff\u6362\u4e3a<\/strong><\/td>\n<td><strong>\u4ee3\u4ef7<\/strong><\/td>\n<\/tr>\n<tr>\n<td>50mm\u7a7a\u8c03\u4e3b\u7ba1<\/td>\n<td>40mm\u621632mm<\/td>\n<td>\u6d41\u91cf\u4e0d\u8db3\u3001\u4e0d\u70ed<\/td>\n<\/tr>\n<tr>\n<td>40mm\u5730\u6696\u4e3b\u7ba1<\/td>\n<td>25mm<\/td>\n<td>\u80fd\u8017\u9ad8<\/td>\n<\/tr>\n<tr>\n<td>20mm\u5730\u6696\u76d8\u7ba1<\/td>\n<td>16mm<\/td>\n<td>\u6563\u70ed\u91cf\u51cf\u5c11\u7ea615%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">6.9 \u4e24\u8054\u4f9b\u7ba1\u9053\u89c4\u683c\u901f\u67e5\u8868<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7cfb\u7edf\u90e8\u4f4d<\/strong><\/td>\n<td><strong>\u63a8\u8350\u7ba1\u6750<\/strong><\/td>\n<td><strong>\u63a8\u8350\u89c4\u683c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u76d8\u7ba1<\/td>\n<td>PERT<\/td>\n<td>De20<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u4e3b\u7ba1<\/td>\n<td><strong>\u4f1f\u661fF-PPRCT\uff08\u9996\u9009\uff09<\/strong> \/ PPR\uff08S3.2\uff09<\/td>\n<td>\u6309\u6c34\u529b\u8ba1\u7b97<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u652f\u7ba1<\/td>\n<td>\u94dd\u5851\u590d\u5408\u7ba1<\/td>\n<td>De20-De25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e03\u90e8\u5206\uff1a\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u672c\u5206\u6790<\/h2>\n<h3 class=\"wp-block-heading\">7.1 \u6c34\u673a\u4e0e\u6c1f\u673a\u5b89\u88c5\u7684\u672c\u8d28\u5dee\u5f02<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u6c1f\u673a<\/strong><\/td>\n<td><strong>\u6c34\u673a<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u5316\u7a0b\u5ea6<\/td>\n<td>\u9ad8<\/td>\n<td>\u4f4e<\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u6548\u7387<\/td>\n<td>\u9ad8\uff0810+\u53f0\/\u5929\uff09<\/td>\n<td>\u4f4e\uff08\u7ea62\u53f0\/\u5929\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5bf9\u5de5\u827a\u8981\u6c42<\/td>\n<td>\u4e2d\u7b49<\/td>\n<td><strong>\u6781\u9ad8<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4eba\u5de5\u6210\u672c<\/td>\n<td>\u7ea6600\u5143\/\u53f0<\/td>\n<td>800-1200\u5143\/\u53f0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">7.2 \u91d1\u5c5e\u63a5\u5934\u4e09\u9053\u5bc6\u5c01\u5de5\u827a<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5de5\u5e8f<\/strong><\/td>\n<td><strong>\u6750\u6599<\/strong><\/td>\n<td><strong>\u4f5c\u7528<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e00\u9053<\/strong><\/td>\n<td>\u4f18\u8d28\u751f\u6599\u5e26<\/td>\n<td>\u586b\u5145\u87ba\u7eb9\u95f4\u9699<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e8c\u9053<\/strong><\/td>\n<td>\u4e13\u7528\u538c\u6c27\u5bc6\u5c01\u80f6<\/td>\n<td>\u589e\u52a0\u7c98\u63a5\u5f3a\u5ea6\u548c\u8010\u5019\u6027<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e09\u9053<\/strong><\/td>\n<td>\u9ebb\u4e1d<\/td>\n<td>\u589e\u5f3a\u6297\u9707\u52a8\u548c\u6297\u51b7\u70ed\u51b2\u51fb\u80fd\u529b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7981\u6b62<\/strong>\uff1a\u4ec5\u7528\u6db2\u4f53\u751f\u6599\u5e26\uff08\u70ed\u80c0\u51b7\u7f29\u6613\u788e\u88c2\uff0c\u788e\u6e23\u5835\u585e\u6362\u70ed\u5668\uff09<\/p>\n<h3 class=\"wp-block-heading\">7.3 \u70ed\u7194\u710a\u63a5\u9632\u7f29\u5f84\u63d0\u9192<\/h3>\n<p class=\"wp-block-paragraph\">\u63a8\u8350\u4f7f\u7528\u5e26\u9632\u7f29\u5f84\u4e13\u5229\u6280\u672f\u7684\u4e13\u4e1a\u6c34\u673a\u7ba1\uff08\u5982\u4f1f\u661fF-PPRCT\uff09\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u516b\u90e8\u5206\uff1a\u5b9e\u6218\u65b9\u6848\u4e0e\u6c9f\u901a\u8bdd\u672f<\/h2>\n<h3 class=\"wp-block-heading\">8.1 \u9500\u552e\u4e0e\u5ba2\u6237\u6c9f\u901a\u201c\u5927\u767d\u8bdd\u201d<\/h3>\n<p class=\"wp-block-paragraph\"><strong>6.1.1 \u6c34\u673a\u7cfb\u7edf\u5230\u5e95\u662f\u4ec0\u4e48\uff1f<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u6c34\u673a\u672c\u8d28\u4e0a\u5c31\u662f\u4e00\u5957\u53d8\u9891\u6c1f\u673a\u7cfb\u7edf\uff0c\u4e2d\u95f4\u52a0\u4e86\u4e00\u4e2a\u6c1f\u6c34\u6362\u70ed\u5668\u3002\u4e3b\u673a\u8d1f\u8d23\u4ea7\u51b7\/\u4ea7\u70ed\uff0c\u590f\u5929\u51b7\u6c34\u8fdb\u98ce\u673a\u76d8\u7ba1\uff0c\u51ac\u5929\u70ed\u6c34\u8fdb\u5730\u6696\u7ba1\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>6.1.2 \u53d8\u9891\u548c\u5b9a\u9891\u5dee\u5728\u54ea\uff1f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u2705 <strong>\u53d8\u9891\u542f\u52a8<\/strong>\uff1a5\u5339\u673a\u542f\u52a8\u53ea\u97001-2kW\uff0c\u50cf\u6162\u6162\u8e29\u6cb9\u95e8<\/li>\n<li>\u274c <strong>\u5b9a\u9891\u542f\u52a8<\/strong>\uff1a24kW\u9505\u7089\u542f\u52a8\u5373\u6ee1\u8d1f\u8377\uff0c\u50cf\u6cb9\u95e8\u8e29\u5230\u5e95<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>6.1.3 \u7f13\u51b2\u6c34\u7bb1\u5230\u5e95\u6709\u6ca1\u6709\u5fc5\u8981\uff1f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u9891\u7cfb\u7edf<\/strong>\uff1a\u786e\u5b9e\u9700\u8981\uff0c\u5b9a\u9891\u6c34\u6cf5+\u5b9a\u9891\u4e3b\u673a\uff0c\u6d41\u91cf\u6ca1\u6cd5\u8c03<\/li>\n<li><strong>\u5168\u53d8\u9891\u7cfb\u7edf<\/strong>\uff1a\u5b8c\u5168\u4e0d\u9700\u8981\uff0c\u53d8\u9891\u6c34\u6cf5\u53ef\u81ea\u52a8\u5339\u914d\u6d41\u91cf<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>6.1.4 \u6c7d\u8f66\u6cb9\u7bb1\u6bd4\u55bb<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u52a0\u6c34\u7bb1\u5c31\u50cf\u7ed9\u6c7d\u8f66\u52a0\u4e2a\u8d85\u5927\u526f\u6cb9\u7bb1\u3002\u8f66\u91cd\u4e86\u3001\u6cb9\u8017\u9ad8\u4e86\u3001\u94b1\u591a\u82b1\u4e86\uff0c\u4f46\u60a8\u6bcf\u5929\u8fd8\u662f\u53ea\u8dd1\u90a3\u4e48\u8fdc\u3002\u201d<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">8.2 \u6838\u5fc3\u8bdd\u672f\u5e93<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u6c34\u673a\u662f\u4e0d\u662f\u66f4\u8d39\u7535\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5168\u53d8\u9891\u6c34\u673aIPLV\u6781\u9ad8\uff0c\u5730\u6696\u5b63\u8282\u6bd4\u71c3\u6c14\u770140%\u4ee5\u4e0a\u3002<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u6c34\u7ba1\u4f1a\u4e0d\u4f1a\u6f0f\u6c34\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u627f\u8ba4\u98ce\u9669\uff0c\u5f3a\u8c03\u4e09\u9053\u5bc6\u5c01+\u4e09\u91cd\u4fdd\u538b+\u54c1\u724c\u7ba1\u9053\u3002<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u4e3a\u4ec0\u4e48\u8981\u9009\u4e00\u6b21\u7cfb\u7edf\u4e0d\u9009\u4e8c\u6b21\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5168\u53d8\u9891\u662f\u539f\u5382\u6cb9\u7bb1\uff0c\u52a0\u6c34\u7bb1\u662f\u52a0\u526f\u6cb9\u7bb1\u3002<\/p>\n<\/blockquote>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e5d\u90e8\u5206\uff1a\u522b\u5885\u4e13\u6848\u4e66\uff08\u5b9e\u6218\u6848\u4f8b\uff09<\/h2>\n<h3 class=\"wp-block-heading\">9.1 \u9879\u76ee\u80cc\u666f<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9879\u76ee<\/strong><\/td>\n<td><strong>\u4fe1\u606f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5ba2\u6237<\/td>\n<td>\u5f20\u5148\u751f<\/td>\n<\/tr>\n<tr>\n<td>\u5efa\u7b51\u9762\u79ef<\/td>\n<td>400\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u9762\u79ef<\/td>\n<td>\u7ea6283\u33a1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">9.2 \u7f13\u51b2\u6c34\u7bb1\u7684\u771f\u76f8\u2014\u2014\u7cbe\u786e\u6c34\u91cf\u8ba1\u7b97<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ec4\u6210\u90e8\u5206<\/strong><\/td>\n<td><strong>\u6c34\u91cf\uff08L\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u5185\u7f6e\u6c34\u6a21\u5757<\/td>\n<td>\u7ea620<\/td>\n<\/tr>\n<tr>\n<td>9\u53f0\u98ce\u673a\u76d8\u7ba1<\/td>\n<td>\u7ea625<\/td>\n<\/tr>\n<tr>\n<td>50mm\u4e3b\u7ba1\uff08\u7ea680\u7c73\uff09<\/td>\n<td>\u7ea6157<\/td>\n<\/tr>\n<tr>\n<td>\u652f\u7ba1\uff08\u7ea650\u7c73\uff09<\/td>\n<td>\u7ea625<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7cfb\u7edf\u603b\u6c34\u91cf<\/strong><\/td>\n<td><strong>\u7ea6227L<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<ul class=\"wp-block-list\">\n<li>\u4e3b\u673a\u80fd\u529b\uff1a28kW<\/li>\n<li>\u5f00\u5229\u53c2\u8003\u6700\u4f4e\u6c34\u91cf\uff1a28 \u00d7 3.25 = <strong>91L<\/strong><\/li>\n<li>\u65e5\u7acb\u53c2\u8003\u6700\u4f4e\u6c34\u91cf\uff1a28 \u00d7 2 = <strong>56L<\/strong><\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u7cfb\u7edf\u6c34\u91cf\u8fdc\u8d85\u4e24\u79cd\u6807\u51c6\uff0c\u5b8c\u5168\u4e0d\u9700\u8981\u7f13\u51b2\u6c34\u7bb1\u3002<\/p>\n<h3 class=\"wp-block-heading\">9.3 \u4e09\u79cd\u65b9\u6848\u914d\u7f6e\u4e0e\u6210\u672c\u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u65b9\u6848<\/strong><\/td>\n<td><strong>\u5b9a\u4e49<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u914d\u7f6e<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u65b9\u6848A<\/strong><\/td>\n<td>\u4e00\u6b21\u7cfb\u7edf\uff08\u65e0\u6c34\u7bb1\uff09<\/td>\n<td>1\u4e2a\u53d8\u9891\u6cf5\uff0c\u65e0\u6c34\u7bb1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u65b9\u6848B<\/strong><\/td>\n<td>\u4e00\u6b21\u7cfb\u7edf\uff08\u6709\u6c34\u7bb1\uff09<\/td>\n<td>1\u4e2a\u53d8\u9891\u6cf5\uff0c60L\u6c34\u7bb1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u65b9\u6848C<\/strong><br \/>\u3010\u53cd\u4f8b\u3011<\/td>\n<td>\u4e8c\u6b21\u7cfb\u7edf\uff08\u4ec5\u672b\u7aef\u8d85\u8fc7 15 \u53f0\u6216\u7ba1\u8def\u8d85\u8fc7 200 \u7c73\u65f6\u624d\u7528\uff09<\/td>\n<td>2\u4e2a\u6cf5\uff0c60L\u6c34\u7bb1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><em>\u8bf4\u660e\uff1a\u65b9\u6848 C \u5217\u5728\u8fd9\u91cc\u662f\u4e3a\u4e86\u628a\u4ee3\u4ef7\u7b97\u6e05\u695a\uff0c\u4e0d\u662f\u53ef\u9009\u914d\u7f6e\u3002\u672c\u518c\u7b2c\u4e94\u90e8\u5206\u8bb2\u7684\u5e02\u573a\u4e71\u8c61\u4e4b\u4e00\uff0c\u5c31\u662f\u628a\u300c\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u300d\u5f3a\u884c\u6539\u6210\u300c\u4e8c\u6b21\u7cfb\u7edf\u52a0\u7f13\u51b2\u6c34\u7bb1\u300d\u3002\u540c\u53e3\u5f84\u4e0b\u7684 20 \u5e74\u603b\u6295\u5165\u5bf9\u6bd4\u89c1 9.6\u3002<\/em><\/p>\n<h3 class=\"wp-block-heading\">9.4 \u70ed\u60ef\u6027\u7cbe\u786e\u8ba1\u7b97<\/h3>\n<ul class=\"wp-block-list\">\n<li>m=60kg\uff0cC=4.187 kJ\/(kg\u00b7\u2103)\uff0c\u0394T=10\u2103<\/li>\n<li>\u70ed\u91cf Q = 60 \u00d7 4.187 \u00d7 10 \u2248 0.698 kWh<\/li>\n<li>\u4e3b\u673a\u8017\u7535\uff08COP=3.5\uff09= 0.698 \u00f7 3.5 = <strong>0.199 kWh\/\u6b21\u542f\u505c<\/strong><\/li>\n<li>\u5e74\u589e\u52a0\u8017\u7535 = 0.199 \u00d7 1,200 = 238.8 kWh<\/li>\n<li>\u5e74\u589e\u52a0\u7535\u8d39 = 238.8 \u00d7 0.5 = <strong>119.4\u5143<\/strong><\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">9.5 \u7efc\u5408\u80fd\u8017\u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u80fd\u8017\u9879<\/strong><\/td>\n<td><strong>\u65b9\u6848A<\/strong><\/td>\n<td><strong>\u65b9\u6848B<\/strong><\/td>\n<td><strong>\u65b9\u6848C<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5e74\u6c34\u6cf5\u7535\u8d39<\/td>\n<td>126\u5143<\/td>\n<td>126\u5143<\/td>\n<td>288\u5143<\/td>\n<\/tr>\n<tr>\n<td>\u5e74\u4e3b\u673a\u7535\u8d39<\/td>\n<td>2,000\u5143<\/td>\n<td>2,119\u5143<\/td>\n<td>2,119\u5143<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5e74\u603b\u7535\u8d39<\/strong><\/td>\n<td><strong>2,126\u5143<\/strong><\/td>\n<td><strong>2,245\u5143<\/strong><\/td>\n<td><strong>2,407\u5143<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">9.6 20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6295\u5165\u9879<\/strong><\/td>\n<td><strong>\u65b9\u6848A<\/strong><\/td>\n<td><strong>\u65b9\u6848B<\/strong><\/td>\n<td><strong>\u65b9\u6848C<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u521d\u6295\u8d44<\/td>\n<td>\u57fa\u51c6<\/td>\n<td>+3,000\u5143<\/td>\n<td>+6,500\u5143<\/td>\n<\/tr>\n<tr>\n<td>20\u5e74\u7535\u8d39<\/td>\n<td>42,520\u5143<\/td>\n<td>44,900\u5143<\/td>\n<td>48,140\u5143<\/td>\n<\/tr>\n<tr>\n<td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td>\n<td><strong>\u57fa\u51c6<\/strong><\/td>\n<td><strong>+6,380\u5143<\/strong><\/td>\n<td><strong>+16,120\u5143<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u65b9\u6848A\u6700\u4f18\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u5341\u90e8\u5206\uff1a\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/h2>\n<h3 class=\"wp-block-heading\">10.1 \u6c34\u7cfb\u7edf\u5e38\u89c1\u552e\u540e\u95ee\u9898<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898\u73b0\u8c61<\/strong><\/td>\n<td><strong>\u53ef\u80fd\u539f\u56e0<\/strong><\/td>\n<td><strong>\u6392\u67e5\u65b9\u5411<\/strong><\/td>\n<td><strong>\u89e3\u51b3\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u62a5\u6c34\u6d41\u6545\u969c\uff087A\uff09<\/td>\n<td>\u6c34\u538b\u8fc7\u4f4e\u3001\u8fc7\u6ee4\u5668\u5835\u585e\u3001\u6c34\u6cf5\u5f02\u5e38<\/td>\n<td>\u68c0\u67e5\u538b\u529b\u3001\u6e05\u6d17\u8fc7\u6ee4\u5668<\/td>\n<td>\u8865\u6c34\u3001\u6e05\u6d17\u3001\u66f4\u6362\u6c34\u6cf5<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u9891\u7e41\u542f\u505c<\/td>\n<td>\u7f13\u51b2\u6c34\u7bb1\u914d\u7f6e\u4e0d\u5f53\u3001\u6c34\u91cf\u4e0d\u8db3<\/td>\n<td>\u68c0\u67e5\u6c34\u7bb1\u5bb9\u91cf\u3001\u63a5\u7ba1\u65b9\u5f0f<\/td>\n<td>\u6309\u6807\u51c6\u914d\u7f6e\u6c34\u7bb1<\/td>\n<\/tr>\n<tr>\n<td>\u51ac\u5b63\u5236\u70ed\u6548\u679c\u4e0d\u8db3<\/td>\n<td>\u4e3b\u673a\u9009\u578b\u504f\u5c0f\u3001\u6d41\u91cf\u4e0d\u8db3<\/td>\n<td>\u68c0\u67e5\u4e3b\u673a\u529f\u7387\u3001\u7ba1\u5f84<\/td>\n<td>\u52a0\u5927\u4e3b\u673a\u3001\u5347\u7ea7\u7ba1\u5f84<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u673a\u76d8\u7ba1\u7ed3\u9732\u6ef4\u6c34<\/td>\n<td>\u4fdd\u6e29\u4e0d\u826f\u3001\u6392\u6c34\u4e0d\u7545<\/td>\n<td>\u68c0\u67e5\u4fdd\u6e29\u5c42\u3001\u6392\u6c34\u5761\u5ea6<\/td>\n<td>\u4fee\u590d\u4fdd\u6e29\u3001\u758f\u901a\u6392\u6c34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">10.2 \u7cfb\u7edf\u6027\u95ee\u9898\u6839\u6e90\uff08\u8bbe\u8ba1\u9636\u6bb5\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898\u6839\u6e90<\/strong><\/td>\n<td><strong>\u552e\u540e\u8868\u73b0<\/strong><\/td>\n<td><strong>\u8bbe\u8ba1\u9636\u6bb5\u9884\u9632\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u7f13\u51b2\u6c34\u7bb1\u5bb9\u91cf\u4e0d\u8db3<\/td>\n<td>\u4e3b\u673a\u9891\u7e41\u542f\u505c<\/td>\n<td>\u6309 3.25 L\/kW \u53c2\u8003\u503c\u6838\u7b97\u7cfb\u7edf\u6c34\u91cf\uff0c\u4e0d\u8db3\u65f6\u4f18\u5148\u653e\u5927\u4e3b\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u7bb1\u63a5\u7ba1\u9519\u8bef\uff08\u77ed\u8def\uff09<\/td>\n<td>\u6c34\u7bb1\u672a\u53d1\u6325\u4f5c\u7528<\/td>\n<td>\u8fdb\u51fa\u6c34\u53e3\u5206\u5c45\u4e24\u4fa7\uff0c\u5e26\u5185\u90e8\u6321\u677f<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u5f84\u8bbe\u8ba1\u504f\u5c0f<\/td>\n<td>\u6d41\u91cf\u4e0d\u8db3\u3001\u62a5\u6c34\u6d41\u6545\u969c<\/td>\n<td>De32\/De40\u4e3b\u7ba1\uff0cDe20\u652f\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>\u672a\u505a\u6c34\u529b\u5e73\u8861<\/td>\n<td>\u5404\u672b\u7aef\u51b7\u70ed\u4e0d\u5747<\/td>\n<td>\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f\u5e03\u7ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">10.3 \u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u4fdd\u9879\u76ee<\/strong><\/td>\n<td><strong>\u5468\u671f<\/strong><\/td>\n<td><strong>\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8fc7\u6ee4\u5668\u6e05\u6d17<\/td>\n<td>\u6bcf\u5b63<\/td>\n<td>\u6e05\u6d17Y\u578b\u8fc7\u6ee4\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u6c34\u8d28\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5PH\u503c\u3001\u6d4a\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5\u8fd0\u884c\u68c0\u6d4b<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u566a\u97f3\u3001\u632f\u52a8\u3001\u7535\u6d41<\/td>\n<\/tr>\n<tr>\n<td>\u7f13\u51b2\u6c34\u7bb1\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u538b\u529b\u3001\u6392\u6c14\u9600<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u6392\u6c14<\/td>\n<td>\u6bcf\u5b63<\/td>\n<td>\u901a\u8fc7\u81ea\u52a8\u6392\u6c14\u9600\u6392\u6c14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">10.4 \u6c34\u7cfb\u7edf\u6545\u969c\u4ee3\u7801\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4ee3\u7801<\/strong><\/td>\n<td><strong>\u542b\u4e49<\/strong><\/td>\n<td><strong>\u6392\u67e5\u65b9\u5411<\/strong><\/td>\n<\/tr>\n<tr>\n<td>7A<\/td>\n<td>\u6c34\u538b\u8fc7\u4f4e\/\u6d41\u91cf\u8fc7\u5c0f<\/td>\n<td>\u8865\u6c34\u3001\u6e05\u6d17\u8fc7\u6ee4\u5668\u3001\u68c0\u67e5\u6c34\u6cf5<\/td>\n<\/tr>\n<tr>\n<td>E1<\/td>\n<td>\u9ad8\u538b\u4fdd\u62a4<\/td>\n<td>\u68c0\u67e5\u6c34\u6d41\u91cf\u3001\u6362\u70ed\u5668\u7ed3\u57a2<\/td>\n<\/tr>\n<tr>\n<td>E2<\/td>\n<td>\u4f4e\u538b\u4fdd\u62a4<\/td>\n<td>\u68c0\u67e5\u51b7\u5a92\u6cc4\u6f0f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u5341\u4e00\u90e8\u5206\uff1a\u5ba2\u6237\u5e38\u89c1\u8d28\u7591\u300c\u5c0f\u9a6c\u62c9\u5927\u8f66\u300d\u5b8c\u6574\u5e94\u5bf9<\/h2>\n<h4 class=\"wp-block-heading\">11..1 \u95ee\u9898\u6839\u6e90\u5206\u6790<\/h4>\n<p class=\"wp-block-paragraph\"><strong>\u6280\u672f\u6839\u6e90<\/strong>\uff1a\u6df7\u6dc6\u6c1f\u673a\u548c\u6c34\u673a\u7684\u914d\u7f6e\u903b\u8f91<\/p>\n<ul class=\"wp-block-list\">\n<li>\u6c1f\u673a\u662f\u51b7\u5a92\u76f4\u8fde\u7684\u4e00\u6b21\u5206\u914d\uff0c\u6c34\u673a\u662f\u4ee5\u6c34\u8f7d\u51b7\u3001\u518d\u628a\u51b7\u70ed\u6c34\u9001\u7ed9\u672b\u7aef<\/li>\n<li>\u4e24\u79cd\u7cfb\u7edf\u7684\u7269\u7406\u7ea6\u675f\u5b8c\u5168\u4e0d\u540c\uff1a\u6c1f\u673a\u5361\u5728\u8fde\u63a5\u7387\uff0c\u6c34\u673a\u5361\u5728\u6c34\u6e29\u4e0e\u6d41\u91cf<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5fc3\u7406\u6839\u6e90<\/strong>\uff1a\u628a\u6c1f\u673a\u201c\u5168\u5f00\u8d85\u8d1f\u8377\u635f\u574f\u201d\u7684\u98ce\u9669\u9519\u8bef\u8fc1\u79fb\u5230\u6c34\u673a\u4e0a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5ba2\u6237\u62c5\u5fc3\u201c\u5185\u673a\u5927\u4e86\u3001\u53f0\u6570\u591a\u4e86\u3001\u4e3b\u673a\u5c0f\u4e86\u201d\u4f1a\u201c\u542d\u54e7\u542d\u54e7\u62c9\u4e0d\u52a8\u3001\u62c9\u5598\u6c14\u3001\u62c9\u62a5\u5e9f\u201d<\/li>\n<li>\u8fd9\u79cd\u6050\u60e7\u6e90\u4e8e\u7ecf\u9a8c\u7684\u9519\u8bef\u8fc1\u79fb<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5e02\u573a\u6839\u6e90<\/strong>\uff1a\u90e8\u5206\u4e0d\u826f\u5546\u5bb6\u5229\u7528\u5ba2\u6237\u6050\u60e7\u63a8\u9500\u66f4\u5927\u7684\u4e3b\u673a<\/p>\n<h4 class=\"wp-block-heading\">11..2 \u539f\u7406\u8bb2\u89e3(\u9500\u552e\u5fc5\u8bfb)<\/h4>\n<p class=\"wp-block-paragraph\"><strong>\u6c1f\u673a\u4e3a\u4ec0\u4e48\u201c\u5fc5\u987b\u914d\u5927\u201d\uff1f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u4e00\u6b21\u7cfb\u7edf\uff1a\u51b7\u5a92\u76f4\u63a5\u4ece\u538b\u7f29\u673a\u5206\u914d\u5230\u5404\u5185\u673a<\/li>\n<li>\u8fde\u63a5\u7387\u9650\u5236\uff1a\u5185\u673a\u603b\u529f\u7387\u00f71.3=\u5916\u673a\u6700\u5c0f\u529f\u7387<\/li>\n<li>170\u33a1\u793a\u4f8b\uff1a\u5185\u673a\u603b\u529f\u7387\u224834kW \u2192 \u5916\u673a\u226526kW<\/li>\n<li>\u98ce\u9669\uff1a\u5168\u5f00\u65f6\u5c0f\u4e3b\u673a\u76f4\u63a5\u62a5\u6545\u969c\u751a\u81f3\u635f\u574f<\/li>\n<li><strong>\u8fd9\u5c31\u662f\u5ba2\u6237\u62c5\u5fc3\u7684\u201c\u62c9\u62a5\u5e9f\u201d\u5728\u6c1f\u673a\u4e0a\u7684\u771f\u5b9e\u8868\u73b0<\/strong><\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u6c34\u673a\u4e3a\u4ec0\u4e48\u201c\u53ef\u4ee5\u914d\u5c0f\u201d\uff1f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u6c34\u8def\u4e32\u8054\uff1a\u4e3b\u673a\u2192\u6c34\u529b\u6a21\u5757\u2192\u6c34\u73af\u8def\u2192\u672b\u7aef\uff0c\u538b\u7f29\u673a\u4e0d\u76f4\u63a5\u9762\u5bf9\u672b\u7aef<\/li>\n<li>\u538b\u7f29\u673a\u4e0d\u76f4\u63a5\u9762\u5bf9\u672b\u7aef\uff0c\u6c34\u6cf5\u51b3\u5b9a\u6d41\u91cf<\/li>\n<li>\u53ef\u6309\u5b9e\u9645\u4f7f\u7528\u9700\u6c42\u914d\u7f6e\uff0c\u4e0d\u62c5\u5fc3\u201c\u62c9\u62a5\u5e9f\u201d<\/li>\n<li>170\u33a1\u793a\u4f8b\uff1a\u5e38\u5f003\u53f0(5-8kW)\uff0c\u914d\u5c0f\u4e3b\u673a\u5c31\u591f\u4e86<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u5730\u6696\u4fa7\u4e3a\u4ec0\u4e48\u662f\u786c\u7ea6\u675f\uff1f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u5730\u6696\u5168\u7a7a\u95f4\u8f90\u5c04\u91c7\u6696\uff0c\u70ed\u91cf\u8fde\u7eed\u9700\u6c42<\/li>\n<li>\u8bbe\u8ba1\u8d1f\u8377\u4e0d\u4f4e\u4e8e100W\/\u33a1<\/li>\n<li>170\u33a1\u9700\u898117kW\u70ed\u529f\u7387\uff0c\u4e3b\u673a\u4e0d\u80fd\u4f4e\u4e8e\u6b64\u914d\u7f6e<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">11..3 \u5c0f\u9a6c\u62c9\u5927\u8f66\u7684\u4e94\u79cd\u7ef4\u5ea6\u5bf9\u7167\u8868<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u8868\u73b0<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<td><strong>\u9884\u9632\/\u89e3\u51b3\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>1. \u6c1f\u673a\u5168\u5f00\u8d85\u8d1f\u8377<\/strong><\/td>\n<td>\u4e3b\u673a\u8fc7\u5c0f\uff0c\u5185\u673a\u5168\u5f00\u65f6\u538b\u7f29\u673a\u8d85\u8f7d\u3001\u62a5\u6545\u969c\u3001\u635f\u574f<\/td>\n<td>\u6c1f\u7cfb\u7edf\u591a\u8054\u673a<\/td>\n<td>\u6309\u8fde\u63a5\u7387\u9650\u5236\u914d\u7f6e\uff0c\u5916\u673a\u2265\u5185\u673a\u603b\u529f\u7387\u00f71.3<\/td>\n<\/tr>\n<tr>\n<td><strong>2. \u6c1f\u673a\u65e5\u5e38\u5927\u9a6c\u62c9\u5c0f\u8f66<\/strong><\/td>\n<td>\u5916\u673a\u6309\u603b\u5185\u673a\u914d\u7f6e\uff0c\u5ba2\u6237\u53ea\u5f001-2\u53f0\uff0c\u9891\u7e41\u542f\u505c\u3001\u80fd\u8017\u9ad8<\/td>\n<td>\u6c1f\u7cfb\u7edf\u591a\u8054\u673a<\/td>\n<td>\u65e0\u6cd5\u5b8c\u5168\u907f\u514d\uff0c\u9009\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u3001\u914d\u8054\u52a8\u63a7\u5236<\/td>\n<\/tr>\n<tr>\n<td><strong>3. \u6c34\u673a\u5730\u6696\u5168\u5f00\u4e0d\u8db3<\/strong><\/td>\n<td>\u5916\u673a\u6309\u7a7a\u8c03\u5e38\u5f00\u914d\u7f6e\uff0c\u51ac\u5929\u5168\u5c4b\u5730\u6696\u5e26\u4e0d\u52a8<\/td>\n<td>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/td>\n<td>\u6309\u5730\u6696\u8bbe\u8ba1\u8d1f\u8377\u914d\u7f6e(100W\/\u33a1)\uff0c\u9009\u5bbd\u53d8\u9891\u4e3b\u673a<\/td>\n<\/tr>\n<tr>\n<td><strong>4. \u6c34\u673a\u7a7a\u8c03\u4fa7\u5927\u9a6c\u62c9\u5c0f\u8f66<\/strong><\/td>\n<td>\u5916\u673a\u6309\u5730\u6696\u5168\u8d1f\u8377\u914d\u7f6e\uff0c\u590f\u5929\u7a7a\u8c03\u53ea\u5f001-2\u53f0\uff0c\u4f4e\u9891\u6548\u7387\u5dee<\/td>\n<td>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/td>\n<td>\u9009\u4f4e\u9891\u6027\u80fd\u597d\u7684\u538b\u7f29\u673a(\u65e5\u7acb\u53cc\u8f6c\u5b50)\uff0c\u914d\u53d8\u9891\u6c34\u6cf5<\/td>\n<\/tr>\n<tr>\n<td><strong>5. \u5ba2\u6237\u5fc3\u7406\u7ef4\u5ea6<\/strong><\/td>\n<td>\u62c5\u5fc3\u4e3b\u673a\u201c\u62c9\u62a5\u5e9f\u201d\uff0c\u5b9e\u9645\u662f\u6c1f\u673a\u7ecf\u9a8c\u7684\u9519\u8bef\u8fc1\u79fb<\/td>\n<td>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/td>\n<td>\u8bb2\u6e05\u539f\u7406\uff1a\u6c34\u673a\u538b\u7f29\u673a\u4e0d\u76f4\u63a5\u9762\u5bf9\u672b\u7aef\uff0c\u4e0d\u5b58\u5728\u300c\u62c9\u62a5\u5e9f\u300d\u98ce\u9669<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">11..4 \u65e5\u7acb vs \u7ea6\u514b\u5bf9\u6bd4\u8981\u70b9<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u7ea6\u514b<\/strong>\uff1a\u6c34\u673a\u9500\u91cf\u9ad8\u4e3b\u8981\u6765\u81ea\u5546\u7528\uff0c\u5bb6\u7528\u6c34\u673a\u6838\u5fc3\u6280\u672f(\u538b\u7f29\u673a)\u6765\u81ea\u65e5\u7acb<\/li>\n<li><strong>\u65e5\u7acb<\/strong>\uff1a\u5168\u94fe\u6761\u81ea\u7814\uff0c\u4ece\u538b\u7f29\u673a\u5230\u53d8\u9891\u5668\u5230\u63a7\u5236\u7cfb\u7edf\uff0c\u53d8\u9891\u63a7\u5236\u903b\u8f91\u6210\u719f<\/li>\n<li><strong>\u5185\u673a\u4ee3\u5dee<\/strong>\uff1a\u5168\u5c01\u95ed\u76f4\u6d41\u65e0\u5237\u7535\u673a+\u6807\u914d\u63d0\u5347\u6cf5<\/li>\n<li><strong>\u7cfb\u7edf\u8bbe\u8ba1<\/strong>\uff1a\u4e00\u6b21\u7cfb\u7edf\u65e0\u6c34\u7bb1\u66f4\u8282\u80fd<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">11..5 \u62c6\u673a\u89c6\u9891\u5f15\u7528<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u7ea6\u514b\u6c34\u673a\u62c6\u673a\u89c6\u9891<\/strong>\uff1a\u5c55\u793a\u5185\u90e8\u65e5\u7acb\u538b\u7f29\u673a<\/li>\n<li><strong>\u65e5\u7acb\u6c34\u5885\u9002\u62c6\u673a\u89c6\u9891<\/strong>\uff1a\u5c55\u793a\u81ea\u7814\u538b\u7f29\u673a\u3001\u53d8\u9891\u5668\u3001\u63a7\u5236\u7cfb\u7edf<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">\u4e24\u8054\u4f9b\u5e38\u89c1\u95ee\u9898<\/h2>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u6c34\u7cfb\u7edf\u4e3b\u673a\u4ee5\u540e\u80fd\u4e0d\u80fd\u6362\u54c1\u724c\uff1f<\/summary>\n<p>\u7b54\uff1a\u80fd\u3002\u6c34\u8def\u53ea\u8ba4\u8fdb\u51fa\u6c34\u6e29\u548c\u6d41\u91cf\uff0c\u4e0d\u8ba4\u54c1\u724c\u3002\u5730\u6696\u7ba1\u8def\u57cb\u5728\u5730\u9762\u91cc\uff0c\u4e3b\u673a\u88c5\u5728\u8bbe\u5907\u95f4\uff0c\u6362\u4e3b\u673a\u4e0d\u7528\u52a8\u5730\u9762\u3002\u4f46\u6362\u4e4b\u524d\u8981\u6838\u4e09\u6837\uff1a\u51fa\u6c34\u6e29\u5ea6\u591f\u4e0d\u591f\u3001\u6d41\u91cf\u7ed9\u4e0d\u7ed9\u5f97\u8d77\u3001\u8054\u52a8\u63a7\u5236\u80fd\u4e0d\u80fd\u63a5\u4e0a\u3002\u4e09\u6837\u5bf9\u4e0a\u624d\u53eb\u80fd\u6362\uff0c\u53ea\u662f\u300c\u63a5\u53e3\u63d2\u5f97\u4e0a\u300d\u4e0d\u7b97\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5929\u6c34\u5730\u6c34\u7684\u672b\u7aef\u53ef\u4ee5\u81ea\u5df1\u9009\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u53ef\u4ee5\uff0c\u4f46\u8981\u5b88\u6c34\u6e29\u8fd9\u4e00\u6761\u3002\u5730\u6696\u76d8\u7ba1\u7528 35 \u5230 45 \u5ea6\uff0c\u98ce\u673a\u76d8\u7ba1\u590f\u5929\u4f9b\u51b7 7 \u5230 12 \u5ea6\u3001\u51ac\u5929\u4f9b\u70ed 45 \u5230 50 \u5ea6\uff0c\u6696\u6c14\u7247\u4e00\u822c\u8981 60 \u5230 80 \u5ea6\u3002\u540c\u4e00\u6c34\u6e29\u6863\u7684\u672b\u7aef\u53ef\u4ee5\u6df7\u5728\u4e00\u4e2a\u6c34\u73af\u8def\u4e0a\uff0c\u8de8\u6863\u7684\u8981\u52a0\u6df7\u6c34\u88c5\u7f6e\u6216\u8005\u914d\u9ad8\u6e29\u673a\u578b\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u662f\u5929\u6c1f\u5730\u6c34\u8fd8\u662f\u5929\u6c34\u5730\u6c34\uff1f<\/summary>\n<p>\u7b54\uff1a\u90fd\u662f\u3002\u4e24\u8054\u4f9b\u8bf4\u7684\u662f\u7a7a\u8c03\u52a0\u5730\u6696\u4e24\u5957\u672b\u7aef\uff0c\u4e0d\u662f\u6307\u4ecb\u8d28\u3002\u5929\u6c1f\u5730\u6c34\u662f\u5929\u4e0a\u8d70\u6c1f\u3001\u5730\u4e0a\u8d70\u6c34\uff1b\u5929\u6c34\u5730\u6c34\u662f\u5929\u4e0a\u8d70\u6c34\u3001\u5730\u4e0a\u4e5f\u8d70\u6c34\u3002\u4e24\u6761\u8def\u90fd\u53eb\u4e24\u8054\u4f9b\uff0c\u9009\u54ea\u6761\u770b\u9762\u79ef\u3001\u672b\u7aef\u6570\u91cf\u548c\u8981\u4e0d\u8981\u6e29\u6e7f\u5206\u5f00\u63a7\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u54ea\u4e2a\u66f4\u7701\u7535\uff1f<\/summary>\n<p>\u7b54\uff1a\u6ca1\u6709\u7edf\u4e00\u7b54\u6848\uff0c\u53d6\u51b3\u4e8e\u4e3b\u673a\u80fd\u6548\u3001\u6c34\u8def\u8bbe\u8ba1\u548c\u5b9e\u9645\u5f00\u673a\u7387\u3002\u5929\u6c1f\u5730\u6c34\u5c11\u4e00\u53f0\u5faa\u73af\u6c34\u6cf5\u548c\u7f13\u51b2\u6c34\u7bb1\uff0c\u7a7a\u8c03\u4fa7\u964d\u6e29\u5feb\uff1b\u5929\u6c34\u5730\u6c34\u7684\u6c34\u84c4\u51b7\u597d\uff0c\u5927\u9762\u79ef\u540c\u65f6\u5f00\u65f6\u4e3b\u673a\u542f\u505c\u5c11\u3002\u540c\u4e00\u53f0\u4e3b\u673a\u3001\u540c\u4e00\u5957\u672b\u7aef\uff0c\u4e24\u6761\u8def\u7684\u5dee\u8ddd\u8fdc\u5c0f\u4e8e\u9009\u578b\u548c\u65bd\u5de5\u505a\u9519\u7684\u5dee\u8ddd\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5929\u6c1f\u5730\u6c34\u80fd\u4e0d\u80fd\u505a\u5230\u9664\u6e7f\u4e0d\u964d\u6e29\uff1f<\/summary>\n<p>\u7b54\uff1a\u80fd\uff0c\u4f46\u53ea\u6709\u4e00\u79cd\u914d\u6cd5\uff1a\u5168\u6548\u5916\u673a\u914d\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u3002\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u53ea\u80fd\u914d\u5168\u6548\u5916\u673a\uff0c\u914d\u4e0d\u5230 AQ \u548c NQ \u4e0a\uff0c\u8fd9\u662f\u5382\u65b9\u7684\u786c\u89c4\u5219\u3002\u6240\u4ee5\u60f3\u8981\u6e29\u6e7f\u5206\u5f00\u63a7\uff0c\u9009\u578b\u65f6\u5148\u5b9a\u5168\u6548\uff0c\u518d\u8c08\u5176\u4ed6\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a90 \u5230 160 \u5e73\u65b9\u7c73\u7684\u5e73\u5c42\u9009\u54ea\u4e00\u79cd\uff1f<\/summary>\n<p>\u7b54\uff1a\u4f18\u5148\u770b\u5929\u6c1f\u5730\u6c34\u7684\u667a\u4eab AQ \u4e00\u4f53\u673a\u3002\u5b83\u7684\u6c34\u6a21\u5757\u88c5\u5728\u5916\u673a\u5185\u90e8\uff0c\u4e0d\u5360\u8bbe\u5907\u4f4d\uff0c\u5e26\u70ed\u56de\u6536\u751f\u6d3b\u70ed\u6c34\uff0c\u7a7a\u8c03\u5730\u6696\u70ed\u6c34\u4e00\u673a\u89e3\u51b3\u3002\u5982\u679c\u5916\u673a\u4f4d\u5bbd\u88d5\u3001\u53ea\u8981\u51b7\u6696\u4e0d\u8981\u70ed\u6c34\uff0c\u4e5f\u53ef\u4ee5\u770b NQ\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u522b\u5885\u4e3a\u4ec0\u4e48\u4e0d\u80fd\u914d\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\uff1f<\/summary>\n<p>\u7b54\uff1a\u522b\u5885\u672c\u6765\u8d70\u4e24\u7ba1\u5236\u3002\u5b83\u7684\u5ba4\u5185\u673a\u662f\u4e24\u7ba1\u5236\u5171\u7528\u5185\u673a\uff0c\u6c34\u6a21\u5757\u662f\u4e24\u7ba1\u5236\u6c34\u6a21\u5757\uff0c\u53ea\u914d VAM mini \u2161\u3001\u5c0a\u777f\u65e0\u754c\u3001\u5c0a\u777f\u522b\u5885\u8fd9\u4e00\u6761\u7ebf\u3002\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u53ea\u9002\u914d\u5c0a\u777f\u5168\u6548\u5916\u673a\uff0c\u522b\u5885\u4e0d\u5728\u5176\u5217\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u6c34\u6a21\u5757\u662f\u4ec0\u4e48\uff0c\u88c5\u5728\u54ea\u91cc\uff1f<\/summary>\n<p>\u7b54\uff1a\u6c34\u6a21\u5757\u5c31\u662f\u6c1f\u6c34\u6362\u70ed\u5668\uff0c\u6c1f\u4fa7\u7684\u70ed\u91cf\u5728\u8fd9\u91cc\u4ea4\u7ed9\u6c34\u3002\u667a\u4eab AQ \u548c NQ \u7684\u6c34\u6a21\u5757\u96c6\u6210\u5728\u5916\u673a\u5185\u90e8\uff0c\u4e0d\u9700\u8981\u53e6\u9009\uff1b\u5168\u6548\u548c\u522b\u5885\u7684\u6c34\u6a21\u5757\u662f\u72ec\u7acb\u4e00\u53f0\uff0c\u8981\u53e6\u5360\u4e00\u4e2a\u8bbe\u5907\u4f4d\uff0c\u8fd8\u8981\u53e6\u914d\u63a7\u5236\u5668\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u548c\u7a7a\u8c03\u52a0\u5730\u6696\u5206\u5f00\u88c5\uff0c\u5dee\u5728\u54ea\uff1f<\/summary>\n<p>\u7b54\uff1a\u5dee\u5728\u4e00\u53f0\u4e3b\u673a\u8fd8\u662f\u4e24\u53f0\u3002\u5206\u5f00\u88c5\u662f\u4e00\u53f0\u7a7a\u8c03\u5916\u673a\u52a0\u4e00\u53f0\u71c3\u6c14\u58c1\u6302\u7089\uff1b\u4e24\u8054\u4f9b\u662f\u4e00\u53f0\u70ed\u6cf5\u4e3b\u673a\u540c\u65f6\u7ba1\u7a7a\u8c03\u548c\u5730\u6696\uff0c\u7701\u6389\u71c3\u6c14\u7089\uff0c\u672b\u7aef\u5171\u7528\u4e00\u5957\u6c34\u5730\u6696\u3002\u9020\u4ef7\u3001\u80fd\u8017\u3001\u540e\u671f\u7ef4\u62a4\u90fd\u4e0d\u4e00\u6837\uff0c\u8981\u770b\u5f53\u5730\u6c14\u4ef7\u7535\u4ef7\u548c\u623f\u5b50\u4fdd\u6e29\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e8c\u8054\u4f9b\u548c\u4e24\u8054\u4f9b\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/summary>\n<p>\u7b54\uff1a\u6ca1\u6709\u533a\u522b\uff0c\u662f\u540c\u4e00\u5957\u7cfb\u7edf\u3002\u4e8c\u8054\u4f9b\u5c5e\u4e8e\u5e02\u573a\u53e3\u8bed\u5199\u6cd5\uff0c\u884c\u4e1a\u6807\u51c6\u672f\u8bed\u662f\u4e24\u8054\u4f9b\uff0c\u6307\u7684\u662f\u7a7a\u8c03\u52a0\u5730\u6696\u4e24\u5957\u672b\u7aef\u5171\u7528\u4e00\u53f0\u4e3b\u673a\u3002\u5199\u65b9\u6848\u3001\u7b7e\u5408\u540c\u3001\u770b\u5382\u5bb6\u578b\u53f7\u518c\uff0c\u4e00\u5f8b\u7528\u300c\u4e24\u8054\u4f9b\u300d\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u3001\u4e09\u6052\u3001\u4e94\u6052\u5230\u5e95\u662f\u4ec0\u4e48\u5173\u7cfb\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e09\u4e2a\u8bcd\u8bf4\u7684\u662f\u4e0d\u540c\u7ef4\u5ea6\uff0c\u522b\u6df7\u3002\u4e24\u8054\u4f9b\u8bf4\u7684\u662f\u300c\u4e00\u5957\u4e3b\u673a\u540c\u65f6\u5e26\u7a7a\u8c03\u548c\u5730\u6696\u300d\u2014\u2014\u662f\u7cfb\u7edf\u67b6\u6784\u3002\u4e09\u6052\u3001\u4e94\u6052\u8bf4\u7684\u662f\u300c\u5ba4\u5185\u73af\u5883\u8981\u505a\u5230\u54ea\u51e0\u4e2a\u6307\u6807\u6052\u5b9a\u300d\u2014\u2014\u662f\u8212\u9002\u5ea6\u76ee\u6807\u3002\u4e00\u4e2a\u623f\u5b50\u53ef\u4ee5\u65e2\u662f\u4e24\u8054\u4f9b\uff08\u67b6\u6784\uff09\uff0c\u53c8\u505a\u4e94\u6052\uff08\u76ee\u6807\uff09\uff0c\u4e24\u8005\u4e0d\u51b2\u7a81\uff1a\u4e24\u8054\u4f9b\u6c34\u673a\u5f53\u51b7\u70ed\u6e90\uff0c\u518d\u53e0\u52a0\u8f90\u5c04\u672b\u7aef\u548c\u667a\u63a7\u53bb\u5b9e\u73b0\u4e94\u6052\u3002\u6240\u4ee5\u4e24\u8054\u4f9b\u662f\u300c\u9aa8\u67b6\u300d\uff0c\u4e09\u6052\u4e94\u6052\u662f\u300c\u4f53\u611f\u6807\u51c6\u300d\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u590f\u5929\u5236\u51b7\u51ac\u5929\u91c7\u6696\uff0c\u5730\u6696\u6c34\u6e29\u600e\u4e48\u4fdd\u8bc1\u4e0d\u8d85\u6807\uff1f<\/summary>\n<p>\u7b54\uff1a\u9760\u4e3b\u673a\u7684\u5730\u6696\u5de5\u51b5\u548c\u6df7\u6c34\uff0f\u8054\u52a8\u63a7\u5236\u4e24\u9053\u5173\u3002\u4e3b\u673a\u7684\u5730\u6696\u6a21\u5f0f\u51fa\u6c34\u6e29\u5ea6\u63a7\u5236\u5728 35 \u5230 45 \u5ea6\uff0c\u672c\u6765\u5c31\u4e0d\u662f\u70e7\u5230 60 \u5ea6\u7684\u6696\u6c14\u7247\u5de5\u51b5\uff1b\u5982\u679c\u672b\u7aef\u662f\u4f4e\u6e29\u5730\u6696\uff08\u4e00\u822c\u4f9b\u6c34 35 \u5230 40 \u5ea6\uff09\uff0c\u4e3b\u673a\u76f4\u63a5\u4f9b\uff1b\u5982\u679c\u6237\u578b\u5927\u3001\u7ba1\u8def\u957f\uff0c\u52a0\u4e00\u4e2a\u6df7\u6c34\u4e2d\u5fc3\u6216\u5206\u5ba4\u8054\u52a8\uff0c\u628a\u6c34\u6e29\u7a33\u4f4f\u3001\u4e0d\u8ba9\u5b83\u4e00\u4f1a\u513f\u9ad8\u4e00\u4f1a\u513f\u4f4e\u3002\u6c34\u6e29\u8d85\u6807\u901a\u5e38\u662f\u65bd\u5de5\u6ca1\u505a\u6c34\u529b\u5e73\u8861\u6216\u6ca1\u914d\u7f13\u51b2\u6c34\u7bb1\uff0c\u4e0d\u662f\u4e3b\u673a\u4e0d\u884c\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u6c34\u7cfb\u7edf\u4e3a\u4ec0\u4e48\u5439\u51fa\u6765\u6bd4\u6c1f\u673a\u67d4\u548c\uff1f\u51fa\u6c34\u6e29\u5ea6\u9ad8\u6709\u4ec0\u4e48\u597d\u5904\uff1f<\/summary>\n<p>\u7b54\uff1a\u6c1f\u673a\u51fa\u98ce\u6e29\u5ea6\u4f4e\uff087 \u5230 12 \u5ea6\uff09\uff0c\u98ce\u4e00\u5439\u50cf\u7ad9\u5728\u7a7a\u8c03\u5e95\u4e0b\uff0c\u51c9\u5f97\u300c\u523a\u9aa8\u300d\uff1b\u6c34\u673a\u8d70\u98ce\u673a\u76d8\u7ba1\u65f6\u4f9b\u6c34\u6e29\u5ea6\u9ad8\uff08\u590f\u5929\u4e00\u822c 7 \u5230 12 \u5ea6\u51b7\u6e90\u4f46\u98ce\u76d8\u6362\u70ed\u91cf\u5927\u3001\u51fa\u98ce 15 \u5230 20 \u5ea6\uff09\uff0c\u51fa\u98ce\u6e29\u5ea6\u9ad8\u3001\u98ce\u901f\u4f4e\uff0c\u4f53\u611f\u662f\u300c\u51c9\u800c\u4e0d\u51b7\u300d\u3002\u597d\u5904\u662f\u4e0d\u76f4\u5439\u4f24\u4eba\u3001\u4e0d\u62bd\u5e72\u7a7a\u6c14\u6e7f\u5ea6\uff0c\u957f\u65f6\u95f4\u5f85\u7740\u4e0d\u5934\u75bc\u3001\u4e0d\u5e72\u3002\u8fd9\u4e5f\u662f\u5f88\u591a\u4eba\u8bf4\u6c34\u673a\u300c\u8212\u670d\u300d\u7684\u6839\u672c\u539f\u56e0\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u8d85\u914d\u7387\u662f\u4ec0\u4e48\uff1f\u300c\u5c0f\u9a6c\u62c9\u5927\u8f66\u300d\u5230\u5e95\u5371\u4e0d\u5371\u9669\uff1f<\/summary>\n<p>\u7b54\uff1a\u8d85\u914d\u7387\uff1d\u6240\u6709\u5185\u673a\u603b\u51b7\u91cf\u00f7\u5916\u673a\u989d\u5b9a\u5236\u51b7\u91cf\uff0c\u6bd4\u5982\u5185\u673a\u52a0\u8d77\u6765 10 \u5343\u74e6\u3001\u5916\u673a 8 \u5343\u74e6\uff0c\u8d85\u914d\u7387 125%\u3002\u9002\u5f53\u8d85\u914d\u662f\u5e38\u6001\uff08\u4e0d\u662f\u6240\u6709\u623f\u95f4\u540c\u65f6\u5f00\uff09\uff0c\u4e00\u822c\u63a7\u5236\u5728 120% \u5230 130% \u4ee5\u5185\u3002\u5371\u9669\u7684\u662f\u8d85\u914d\u5230 150% \u4ee5\u4e0a\uff1a\u5916\u673a\u957f\u671f\u6ee1\u8d1f\u8377\u3001\u9891\u7e41\u542f\u505c\u3001\u5236\u51b7\u5236\u70ed\u90fd\u6253\u6298\u6263\uff0c\u590f\u5929\u6700\u70ed\u90a3\u51e0\u5929\u76f4\u63a5\u300c\u5e26\u4e0d\u52a8\u300d\u3002\u6240\u4ee5\u300c\u5c0f\u9a6c\u62c9\u5927\u8f66\u300d\u4e0d\u7edd\u5bf9\u5371\u9669\uff0c\u8d85\u5230\u79bb\u8c31\u624d\u5371\u9669\uff0c\u9009\u578b\u65f6\u6838\u6e05\u695a\u540c\u65f6\u5f00\u673a\u7387\u6700\u5173\u952e\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u6c34\u673a\u6015\u51bb\u5417\uff1f\u6210\u90fd\u51ac\u5929\u8981\u4e0d\u8981\u6392\u7a7a\uff1f<\/summary>\n<p>\u7b54\uff1a\u6c34\u673a\u7ba1\u8def\u91cc\u662f\u6c34\uff0c\u7406\u8bba\u6015\u51bb\uff0c\u4f46\u6210\u90fd\u51ac\u5929\u6781\u7aef\u4f4e\u6e29\u5c11\uff0c\u52a0\u4e0a\u4e09\u9053\u9632\u62a4\u4e00\u822c\u4e0d\u7528\u6392\u7a7a\u3002\u4e00\u662f\u7cfb\u7edf\u52a0\u9632\u51bb\u6db2\uff08\u6309\u5f53\u5730\u6700\u4f4e\u6e29\u9009\u914d\u6bd4\uff09\uff0c\u4e8c\u662f\u673a\u7ec4\u6709\u7535\u8f85\u70ed\u548c\u9632\u51bb\u8fd0\u884c\uff0c\u6c14\u6e29\u964d\u5230\u9608\u503c\u81ea\u52a8\u542f\u52a8\uff1b\u4e09\u662f\u957f\u671f\u79bb\u5bb6\u8bbe\u300c\u9632\u51bb\u6a21\u5f0f\u300d\u800c\u4e0d\u662f\u5173\u673a\u3002\u771f\u6b63\u8981\u6392\u7a7a\u7684\u662f\u90a3\u79cd\u6574\u4e2a\u51ac\u5929\u90fd\u4e0d\u4f4f\u3001\u53c8\u6ca1\u901a\u7535\u6ca1\u4eba\u7ba1\u7684\u7a7a\u623f\u3002\u6b63\u5e38\u4f4f\u5bb6\uff0c\u4fdd\u6301\u901a\u7535\u3001\u8bbe\u597d\u9632\u51bb\u6a21\u5f0f\u5c31\u884c\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e3b\u673a\u300c\u81ea\u7531\u300d\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u6362\u54c1\u724c\u771f\u7684\u53ea\u6362\u4e3b\u673a\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e3b\u673a\u81ea\u7531\u6307\u6c34\u7cfb\u7edf\u7684\u300c\u6c34\u8def\u8ba4\u6c34\u6e29\u6d41\u91cf\u3001\u4e0d\u8ba4\u54c1\u724c\u300d\u2014\u2014\u524d\u9762\u90a3\u6761\u300c\u6362\u54c1\u724c\u300d\u95ee\u7b54\u8bb2\u8fc7\u539f\u7406\u3002\u4f46\u300c\u53ea\u6362\u4e3b\u673a\u300d\u8981\u52a0\u524d\u63d0\uff1a\u65b0\u4e3b\u673a\u7684\u51fa\u6c34\u6e29\u5ea6\u3001\u6d41\u91cf\u3001\u8054\u52a8\u534f\u8bae\u4e09\u6837\u5bf9\u5f97\u4e0a\u539f\u6765\u7684\u672b\u7aef\u548c\u6c34\u8def\u3002\u5bf9\u5f97\u4e0a\uff0c\u6362\u4e3b\u673a\u4e0d\u52a8\u5730\u9762\uff1b\u5bf9\u4e0d\u4e0a\uff08\u6bd4\u5982\u65b0\u4e3b\u673a\u6700\u4f4e\u51fa\u6c34\u6e29\u5ea6\u6bd4\u539f\u7cfb\u7edf\u9ad8\uff0c\u5730\u6696\u76d8\u7ba1\u6309\u4f4e\u6e29\u8bbe\u8ba1\u7684\uff09\uff0c\u6362\u4e86\u4f1a\u5730\u6696\u4e0d\u70ed\u3002\u6240\u4ee5\u300c\u81ea\u7531\u300d\u662f\u76f8\u5bf9\u7684\uff0c\u6362\u4e4b\u524d\u4e00\u5b9a\u628a\u8fd9\u4e09\u6837\u6838\u5bf9\u6e05\u695a\uff0c\u522b\u542c\u300c\u968f\u4fbf\u6362\u300d\u7684\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u667a\u4eab AQ \/ NQ \/ \u5c0a\u777f\u5168\u6548\u2161 \/ \u522b\u5885\u673a\uff0c\u56db\u6863\u600e\u4e48\u9009\uff1f<\/summary>\n<p>\u7b54\uff1a\u56db\u7ef4\u51b3\u7b56\uff1a\u9762\u79ef\u3001\u8981\u4e0d\u8981\u751f\u6d3b\u70ed\u6c34\u3001\u8981\u4e0d\u8981\u6e29\u6e7f\u5206\u5f00\u63a7\u3001\u8bbe\u5907\u4f4d\u5bbd\u4e0d\u5bbd\u88d5\u3002\u667a\u4eab AQ \u4e00\u4f53\u673a\u2014\u2014\u6c34\u6a21\u5757\u5728\u5916\u673a\u5185\u3001\u5e26\u70ed\u56de\u6536\u70ed\u6c34\u3001\u6700\u7701\u8bbe\u5907\u4f4d\uff0c\u5e73\u5c42\u9996\u9009\uff1bNQ\u2014\u2014\u4e0d\u8981\u70ed\u6c34\u3001\u5916\u673a\u4f4d\u5bbd\u88d5\u65f6\u66f4\u4fbf\u5b9c\uff1b\u5c0a\u777f\u5168\u6548\u2161\u2014\u2014\u8981\u6e29\u6e7f\u53cc\u63a7\uff08\u4e09\u7ba1\u5236\u3001\u9664\u6e7f\u4e0d\u964d\u6e29\u3001\u5236\u51b7\u540c\u65f6\u51fa\u70ed\u6c34\uff09\uff0c\u9884\u7b97\u548c\u5c42\u9ad8\u591f\u7684\u9009\u5b83\uff1b\u522b\u5885\u673a\u2014\u2014\u72ec\u680b\uff0f\u5927\u5e73\u5c42\u3001\u4e24\u7ba1\u5236\u5185\u673a\u7ebf\u3001\u8981\u72ec\u7acb\u6c34\u6a21\u5757\u4f4d\u7684\u9009\u5b83\u3002\u4e00\u53e5\u8bdd\uff1a\u5148\u5b9a\u8981\u4e0d\u8981\u70ed\u6c34\u548c\u6e29\u6e7f\u53cc\u63a7\uff0c\u518d\u5b9a\u9762\u79ef\u548c\u8bbe\u5907\u4f4d\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5916\u673a\u4f4d\u7d27\u5f20\u3001\u8bbe\u5907\u95f4\u5c0f\uff0c\u600e\u4e48\u9009\u914d\u6cd5\uff1f<\/summary>\n<p>\u7b54\uff1a\u4f18\u5148\u667a\u4eab AQ \u4e00\u4f53\u673a\uff0c\u5b83\u7684\u6c34\u6a21\u5757\u96c6\u6210\u5728\u5916\u673a\u91cc\uff0c\u4e0d\u989d\u5916\u5360\u8bbe\u5907\u4f4d\uff0c\u6700\u7701\u5730\u65b9\u3002\u5982\u679c\u8fd8\u8981\u6e29\u6e7f\u53cc\u63a7\u53c8\u6ca1\u5730\u65b9\u653e\u72ec\u7acb\u6c34\u6a21\u5757\uff0c\u90a3\u5c31\u5f97\u5728\u88c5\u4fee\u9636\u6bb5\u9884\u7559\u8bbe\u5907\u95f4\uff0c\u6216\u8005\u9009\u5916\u673a\u81ea\u5e26\u90e8\u5206\u529f\u80fd\u7684\u673a\u578b\u3002\u522b\u5885\u673a\u548c\u5168\u6548\u7684\u6c34\u6a21\u5757\u662f\u72ec\u7acb\u4e00\u53f0\uff0c\u6ca1\u8bbe\u5907\u4f4d\u57fa\u672c\u88c5\u4e0d\u4e86\u3002\u6240\u4ee5\u300c\u4f4d\u5b50\u5c0f\u300d\u51e0\u4e4e\u662f\u5148\u7528 AQ\u3001\u518d\u8c08\u5176\u4ed6\u7684\u786c\u7ea6\u675f\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5df2\u88c5\u4fee\u597d\u7684\u623f\u5b50\u80fd\u6539\u4e24\u8054\u4f9b\u6c34\u673a\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u5168\u5c4b\u4e24\u8054\u4f9b\u57fa\u672c\u4e0d\u884c\u3002\u4e24\u8054\u4f9b\u7684\u6c34\u8def\uff08\u5730\u6696\u76d8\u7ba1\u6216\u98ce\u76d8\u3001\u5916\u673a\u5230\u672b\u7aef\u7684\u6c34\u7ba1\uff09\u90fd\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u88c5\u4fee\u5b8c\u518d\u52a8\u7b49\u4e8e\u64ac\u5730\u3001\u62c6\u9876\uff0c\u4ee3\u4ef7\u6bd4\u88c5\u65b0\u7684\u8fd8\u5927\u3002\u5df2\u4f4f\u8fdb\u53bb\u60f3\u6539\u5584\uff0c\u73b0\u5b9e\u8def\u5f84\u662f\u5c40\u90e8\uff1a\u52a0\u660e\u88c5\u6696\u6c14\u7247\u89e3\u51b3\u91c7\u6696\uff0c\u6216\u52a0\u4e00\u53f0\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\u89e3\u51b3\u6e7f\u5ea6\uff0c\u8fd9\u4e24\u6761\u5728 02 \u53f7\u624b\u518c\uff08\u91c7\u6696\u00b7\u70ed\u6c34\uff09\u91cc\u6709\u3002\u771f\u60f3\u8981\u5168\u5c4b\u4e24\u8054\u4f9b\uff0c\u5efa\u8bae\u7b49\u4e0b\u6b21\u7ffb\u65b0\u4e00\u8d77\u505a\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4ec0\u4e48\u5bb6\u5ead\u6700\u9002\u5408\u4e0a\u4e24\u8054\u4f9b\uff1f\u6210\u90fd\u8fd9\u79cd\u6c14\u5019\u9002\u5408\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u6700\u9002\u5408\u4e09\u7c7b\uff1a\u4e00\u662f\u5927\u6237\u578b\uff0f\u522b\u5885\uff0c\u5730\u6696\u9762\u79ef\u5927\u3001\u7528\u70ed\u6cf5\u6bd4\u70e7\u6c14\u7701\uff1b\u4e8c\u662f\u672c\u6765\u5c31\u60f3\u8981\u300c\u7a7a\u8c03\uff0b\u5730\u6696\u300d\u4e00\u5957\u641e\u5b9a\u3001\u5acc\u4e24\u53f0\u8bbe\u5907\u5360\u5730\u65b9\u7684\uff1b\u4e09\u662f\u5bf9\u8212\u9002\u5ea6\u654f\u611f\u3001\u60f3\u8981\u6c34\u673a\u67d4\u548c\u98ce\u611f\u7684\u3002\u6210\u90fd\u5728\u6c14\u5019\u4e0a\u7279\u522b\u9002\u5408\u2014\u2014\u590f\u5929\u95f7\u70ed\u9700\u8981\u5f3a\u529b\u9664\u6e7f\u5236\u51b7\uff0c\u51ac\u5929\u6e7f\u51b7\u5730\u6696\u6bd4\u7a7a\u8c03\u8212\u670d\uff0c\u4e24\u8054\u4f9b\u4e00\u5957\u4e24\u5934\u90fd\u987e\u3002\u552f\u4e00\u7684\u95e8\u69db\u662f\u521d\u88c5\u6bd4\u5355\u7a7a\u8c03\u8d35\uff0c\u9762\u79ef\u5927\u624d\u644a\u5f97\u56de\u6765\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u6c34\u673a\u521d\u88c5\u5927\u6982\u591a\u5c11\u94b1\u4e00\u5e73\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e0d\u62a5\u6b7b\u4ef7\uff0c\u56e0\u4e3a\u6bcf\u6237\u51b7\u70ed\u8d1f\u8377\u3001\u672b\u7aef\u5f62\u5f0f\u3001\u8981\u4e0d\u8981\u70ed\u6c34\u548c\u6e29\u6e7f\u53cc\u63a7\u5dee\u522b\u5f88\u5927\u3002\u7ed9\u4e2a\u533a\u95f4\u53c2\u8003\uff1a\u666e\u901a\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff08\u542b\u7a7a\u8c03\u5730\u6696\uff0c\u4e0d\u542b\u751f\u6d3b\u70ed\u6c34\uff09\u5927\u81f4\u5728\u6bcf\u5e73\u7c73\u51e0\u767e\u5143\u7684\u8bbe\u5907\u52a0\u65bd\u5de5\u533a\u95f4\uff1b\u5e26\u5c0a\u777f\u5168\u6548\u2161\u4e09\u7ba1\u5236\u3001\u8981\u6e29\u6e7f\u53cc\u63a7\u7684\u4f1a\u518d\u4e0a\u4e00\u4e2a\u53f0\u9636\u3002\u51c6\u786e\u6570\u5fc5\u987b\u6309\u6237\u578b\u56fe\u505a\u8d1f\u8377\u8ba1\u7b97\u3001\u73b0\u573a\u52d8\u6d4b\u7ba1\u7ebf\u548c\u8bbe\u5907\u4f4d\u540e\u624d\u6709\u3002\u9f99\u8109\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u548c\u65b9\u6848\uff0c\u6bd4\u53ea\u770b\u9762\u79ef\u5957\u4ef7\u9760\u8c31\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u7528\u4e24\u8054\u4f9b\u6bd4\u70e7\u71c3\u6c14\u58c1\u6302\u7089\uff0c\u4e00\u4e2a\u51ac\u5929\u80fd\u7701\u591a\u5c11\uff1f<\/summary>\n<p>\u7b54\uff1a\u70ed\u6cf5\u9760\u642c\u8fd0\u70ed\u91cf\uff0cCOP \u4e00\u822c 3 \u5230 4\uff0c\u4e5f\u5c31\u662f 1 \u5ea6\u7535\u642c 3 \u5230 4 \u5ea6\u70ed\uff1b\u71c3\u6c14\u58c1\u6302\u7089\u662f\u71c3\u70e7\uff0c\u6548\u7387\u518d\u9ad8\u4e5f\u5c31 90% \u51fa\u5934\u3002\u6240\u4ee5\u540c\u6837\u5236\u70ed\u91cf\uff0c\u4e24\u8054\u4f9b\u7684\u8fd0\u884c\u8d39\u5927\u81f4\u662f\u71c3\u6c14\u7684\u4e8c\u5206\u4e4b\u4e00\u5230\u4e09\u5206\u4e4b\u4e8c\u3002\u9762\u79ef\u8d8a\u5927\u3001\u5730\u6696\u5f00\u5f97\u8d8a\u4e45\uff0c\u7701\u5f97\u8d8a\u591a\uff1b\u5c0f\u9762\u79ef\u3001\u5076\u5c14\u5f00\uff0c\u5dee\u8ddd\u4e0d\u660e\u663e\u3002\u6210\u90fd\u6c14\u4ef7\u4e0d\u4f4e\u3001\u7535\u4ef7\u6709\u5cf0\u8c37\uff0c\u7b97\u4e0b\u6765\u5927\u5e73\u5c42\u548c\u522b\u5885\u7528\u4e24\u8054\u4f9b\u5730\u6696\uff0c\u4e00\u4e2a\u51ac\u5929\u80fd\u7701\u51fa\u4e0d\u5c11\u3002\uff08\u5177\u4f53\u4ee5\u5f53\u5730\u6c14\u4ef7\u7535\u4ef7\u548c\u81ea\u5bb6\u7528\u80fd\u4e60\u60ef\u4e3a\u51c6\uff09<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u6c34\u673a\u5e38\u89c1\u6545\u969c\u6709\u54ea\u4e9b\uff1f<\/summary>\n<p>\u7b54\uff1a\u6c34\u7cfb\u7edf\u6700\u5e38\u89c1\u7684\u51e0\u7c7b\uff0c\u5927\u591a\u8ddf\u300c\u6c34\u300d\u6709\u5173\u800c\u4e0d\u662f\u673a\u5668\u574f\u4e86\uff1a\u4e00\u662f\u6c34\u6cf5\u6c14\u963b\u3001\u7cfb\u7edf\u618b\u6c14\uff0c\u8868\u73b0\u662f\u5730\u6696\u4e00\u534a\u70ed\u4e00\u534a\u4e0d\u70ed\u3001\u6709\u6c34\u6d41\u58f0\uff0c\u6392\u6c14\u5c31\u80fd\u597d\uff1b\u4e8c\u662f Y \u578b\u8fc7\u6ee4\u5668\u5835\uff0c\u6c34\u6d41\u53d8\u5c0f\u3001\u4e3b\u673a\u62a5\u6c34\u6d41\u6545\u969c\uff08\u4ee3\u7801 7A\uff09\uff0c\u6e05\u6d17\u5373\u53ef\uff1b\u4e09\u662f\u6c34\u538b\u6389\u5230\u4e0b\u9650\uff0c\u8865\u6c34\u5c31\u80fd\u6062\u590d\uff1b\u56db\u662f\u6e29\u63a7\u6216\u8054\u52a8\u5931\u7075\uff0c\u672b\u7aef\u4e0d\u5207\u6362\uff0c\u67e5\u63a7\u5236\u5668\u548c\u63a5\u7ebf\u3002\u771f\u7684\u4e3b\u673a\u5927\u6545\u969c\u6bd4\u4f8b\u5f88\u4f4e\uff0c\u591a\u6570\u300c\u574f\u4e86\u300d\u5176\u5b9e\u662f\u7ef4\u4fdd\u6ca1\u505a\u5230\u4f4d\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u6c34\u673a\u540e\u671f\u7ef4\u62a4\u9ebb\u70e6\u5417\uff1f\u591a\u4e45\u4fdd\u517b\u4e00\u6b21\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e0d\u9ebb\u70e6\uff0c\u9891\u7387\u4f4e\u3002\u4e00\u5e74\u505a\u4e00\u6b21\u6362\u5b63\u4fdd\u517b\u5c31\u591f\u4e86\uff1a\u6e05\u6d17 Y \u578b\u8fc7\u6ee4\u5668\u3001\u67e5\u7cfb\u7edf\u6c34\u538b\u3001\u7ed9\u7cfb\u7edf\u6392\u6392\u6c14\u3001\u770b\u6c34\u6cf5\u8fd0\u884c\u58f0\u97f3\u3002\u5730\u6696\u90e8\u5206\u57fa\u672c\u514d\u7ef4\u62a4\uff0c\u7528\u4e2a\u5341\u51e0\u5e74\u7684\u90fd\u6709\u3002\u6bd4\u71c3\u6c14\u7089\u7701\u5fc3\u7684\u662f\u5b83\u6ca1\u6709\u71c3\u70e7\u90e8\u4ef6\u3001\u6ca1\u6709\u79ef\u78b3\u70df\u9053\u8fd9\u4e9b\u8981\u5e74\u5e74\u6e05\u7684\u3002\u771f\u8981\u8bf4\u9ebb\u70e6\uff0c\u662f\u88c5\u4fee\u65f6\u6ca1\u7559\u68c0\u4fee\u53e3\u3001\u8bbe\u5907\u85cf\u6b7b\u89d2\u7684\u90a3\u79cd\uff0c\u6240\u4ee5\u300c\u597d\u7ef4\u62a4\u300d\u662f\u8bbe\u8ba1\u9636\u6bb5\u5b9a\u4e0b\u6765\u7684\uff0c\u4e0d\u662f\u540e\u671f\u52e4\u5feb\u80fd\u8865\u7684\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u7cfb\u7edf\u8ddf\u58c1\u6302\u7089\u5730\u6696\u7cfb\u7edf\u6709\u533a\u522b\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u672b\u7aef\uff08\u57cb\u5728\u5730\u4e0b\u7684\u5730\u6696\u76d8\u7ba1\uff09\u51e0\u4e4e\u4e00\u6837\uff0c\u533a\u522b\u5168\u5728\u300c\u70ed\u6e90\u300d\u548c\u300c\u7cfb\u7edf\u6574\u5408\u300d\u4e0a\u3002\u58c1\u6302\u7089\u5730\u6696\uff1a\u70ed\u6e90\u662f\u71c3\u6c14\u7089\u70e7\u6c34\uff0c\u53ea\u7ba1\u91c7\u6696\uff08\u6216\u5e26\u751f\u6d3b\u70ed\u6c34\uff09\uff0c\u7a7a\u8c03\u5f97\u53e6\u914d\u4e00\u53f0\uff1b\u4e24\u8054\u4f9b\u6c34\u673a\u5730\u6696\uff1a\u70ed\u6e90\u662f\u7a7a\u6c14\u6e90\u70ed\u6cf5\uff0c\u540c\u4e00\u53f0\u4e3b\u673a\u590f\u5929\u8fd8\u80fd\u5e26\u7a7a\u8c03\u5236\u51b7\uff0c\u76f8\u5f53\u4e8e\u300c\u4e00\u673a\u4e24\u7528\u300d\u3002\u8fd0\u884c\u4e0a\uff0c\u70ed\u6cf5\u6548\u7387\u8fdc\u9ad8\u4e8e\u71c3\u6c14\u71c3\u70e7\uff0c\u5927\u9762\u79ef\u957f\u5f00\u66f4\u7701\uff1b\u58c1\u6302\u7089\u80dc\u5728\u521d\u88c5\u4fbf\u5b9c\u3001\u4e0d\u53d7\u7535\u4ef7\u5cf0\u8c37\u5f71\u54cd\u3002\u7b80\u5355\u8bf4\uff1a\u5730\u6696\u7ba1\u5b50\u4e00\u6837\uff0c\u70e7\u6c34\u7684\u300c\u53d1\u52a8\u673a\u300d\u4e0d\u540c\uff0c\u4e24\u8054\u4f9b\u8fd8\u987a\u5e26\u628a\u7a7a\u8c03\u4e5f\u89e3\u51b3\u4e86\u3002<\/p>\n<\/details>\n<h2 class=\"wp-block-heading\">\u5ef6\u4f38\u9605\u8bfb<\/h2>\n<p class=\"wp-block-paragraph\">\u8fd9\u4e00\u518c\u8bb2\u7684\u662f\u9009\u54ea\u6761\u8def\u3002\u5f80\u4e0b\u6bcf\u4e00\u6bb5\u8def\u90fd\u6709\u81ea\u5df1\u7684\u518c\u5b50\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20725\">\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26PE\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05<\/a> \u2014\u2014 \u98ce\u76d8\u4e09\u5c42\u6b21\u4e0e\u96f6\u8d8a\u53c2\u6570\u51c0\u5316\u53e3\u5f84<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20717\">\u6210\u90fd\u51ac\u5b63\u7a7a\u8c03\u5236\u70ed\u597d\u4e0d\u597d\uff0c\u5173\u952e\u770b\u8865\u6c14\u589e\u7113\uff1a\u4e0d\u53ea\u662f\u66f4\u6696\uff0c\u8fd8\u66f4\u7701\u7535<\/a> \u2014\u2014 \u6210\u90fd\u51ac\u5b63\u5236\u70ed\uff0c\u8865\u6c14\u589e\u7113\u80fd\u529b\u4e0e\u8282\u80fd\u4e24\u9762<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20709\">\u4e24\u8054\u4f9b\u53cc\u673a\u8054\u52a8\u3001\u591a\u673a\u8054\u52a8\u600e\u4e48\u63a5\uff1f\u7535\u8def\u8054\u52a8\u548c\u6c34\u8def\u8054\u52a8\u533a\u522b\u5728\u54ea<\/a> \u2014\u2014 \u7535\u8def\u8054\u52a8\u4e0e\u6c34\u8def\u8054\u52a8\u5206\u5c42\u3001\u5355\u673a\u53cc\u673a\u591a\u673a\u600e\u4e48\u9009<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20638\">\u4e24\u8054\u4f9b\u4e00\u6b21\u7cfb\u7edf\u3001\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\uff1f\u201c1.5\u6b21\u7cfb\u7edf\u201d\u662f\u4ec0\u4e48\uff0c\u770b\u8fd9\u56db\u6761\u8bb2\u6e05<\/a>\u2014\u2014\u4e00\u6b21\/\u4e8c\u6b21\u600e\u4e48\u9009\u30011.5\u6b21\u7cfb\u7edf\u7684\u8bf4\u6cd5\u600e\u4e48\u6765\u7684\uff0c\u770b\u8fd9\u4e00\u9875<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u8be6\u60c5\u9875<\/a><\/strong>\uff1a\u667a\u4eab AQ\uff0fNQ \u7684\u9010\u9879\u53c2\u6570\u3001\u5916\u673a\u5c3a\u5bf8\u3001\u63a5\u7ba1\u53e3\u5f84<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<\/a><\/strong>\uff1a\u5929\u6c34\u5730\u6c34\u90a3\u4e00\u8def\u7684\u7cfb\u7edf\u67b6\u6784\u4e0e\u6210\u90fd\u5b9e\u6d4b\u80fd\u8017<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u6210\u90fd\u6c34\u673a vs \u6c1f\u673a\uff1a\u4e24\u8054\u4f9b\u600e\u4e48\u9009<\/a><\/strong>\uff1a\u4e24\u6761\u8def\u7684\u516d\u9879\u5bf9\u6bd4\u4e0e\u9009\u578b\u51b3\u7b56\u8868<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161 \u4ea7\u54c1\u9875<\/a><\/strong>\uff1a\u5168\u6548\u8fd9\u4e00\u53f0\u7684\u8be6\u7ec6\u53c2\u6570\u4e0e\u771f\u5b9e\u6848\u4f8b<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=16059\">\u6210\u90fd\u4e24\u8054\u4f9b\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\uff5c\u4e94\u6b65\u6cd5<\/a><\/strong>\uff1a\u4ece\u91cf\u623f\u5230\u9a8c\u6536\uff0c\u4e00\u5957\u65b9\u6848\u600e\u4e48\u6210\u578b<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=16061\">\u5929\u6c1f\u5730\u6c34\u8bbe\u8ba1\u65b9\u6848\uff1a\u5185\u673a\u3001\u5916\u673a\u3001\u6c34\u6a21\u5757\u600e\u4e48\u5b9a<\/a><\/strong>\uff1a\u8d70\u6c1f\u90a3\u4e00\u652f\u7684\u8bbe\u8ba1\u6b65\u9aa4<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=16063\">\u5929\u6c34\u5730\u6c34\u8bbe\u8ba1\u65b9\u6848\uff1a\u98ce\u673a\u76d8\u7ba1\u3001\u5916\u673a\u3001\u7f13\u51b2\u6c34\u7bb1\u600e\u4e48\u5b9a<\/a><\/strong>\uff1a\u8d70\u6c34\u90a3\u4e00\u652f\u7684\u8bbe\u8ba1\u6b65\u9aa4<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=1395\">\u6210\u90fd\u6696\u901a\u77e5\u8bc6\u4e2d\u5fc3<\/a><\/strong>\uff1a\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u65b0\u98ce\u3001\u51c0\u6c34\u3001\u70ed\u6c34\uff0c\u5168\u7ad9\u77e5\u8bc6\u6309\u54c1\u7c7b\u5f52\u6863<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=667\">01 \u53f7\u624b\u518c\uff1a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03<\/a><\/strong>\uff1a\u6c1f\u673a\u672c\u4f53\u3001\u538b\u7f29\u673a\u9009\u578b\u3001\u4e09\u7ba1\u5236\u539f\u7406<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=669\">02 \u53f7\u624b\u518c\uff1a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34<\/a><\/strong>\uff1a\u5730\u6696\u600e\u4e48\u94fa\u3001\u4e3b\u7ba1\u8d70\u591a\u5927\u3001\u6c34\u529b\u600e\u4e48\u5e73\u8861<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=673\">04 \u53f7\u624b\u518c\uff1a\u4e94\u6052\u207a\u7cfb\u7edf<\/a><\/strong>\uff1a\u6e29\u6e7f\u6c27\u6d01\u9759\u4e94\u4e2a\u7ef4\u5ea6\u7684\u8bbe\u8ba1\u6807\u51c6\u4e0e\u5b9e\u6d4b<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=18579\">\u4e24\u8054\u4f9b\u8981\u4e0d\u8981\u914d\u7f13\u51b2\u6c34\u7bb1\uff1f\u5148\u7b97\u6c34\u91cf\u518d\u5b9a\u5927\u5c0f<\/a><\/strong>\uff1a\u5148\u7b97\u7cfb\u7edf\u603b\u6c34\u91cf\uff0c\u5224\u65ad\u8981\u4e0d\u8981\u914d\u3001\u914d\u591a\u5927<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=18603\">\u7f13\u51b2\u6c34\u7bb1\u88c5\u5728\u54ea\u3001\u600e\u4e48\u63a5\u624d\u6709\u6548\uff1f\u63a5\u9519\u4f4d\u7f6e\u7b49\u4e8e\u767d\u88c5<\/a><\/strong>\uff1a\u63a5\u7ba1\u4f4d\u7f6e\u3001\u6709\u6548\u5bb9\u79ef\u4e0e\u4e09\u62db\u9a8c\u6536<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=18607\">\u7f13\u51b2\u6c34\u7bb1\u3001\u53bb\u8026\u7f50\u3001\u6362\u70ed\u6c34\u7bb1\uff0c\u662f\u4e0d\u662f\u4e00\u56de\u4e8b\uff1f<\/a><\/strong>\uff1a\u4e09\u53ea\u6876\u5404\u6cbb\u4ec0\u4e48\u75c5\uff0c\u522b\u6df7\u7740\u914d<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=5849\">\u6210\u90fd\u65e5\u7acb\u6696\u901a\u89e3\u51b3\u65b9\u6848\u805a\u5408<\/a><\/strong>\uff1a\u6309\u7cfb\u7edf\u5206\u7c7b\u7684\u771f\u5b9e\u5ba2\u6237\u65b9\u6848<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=20629\">\u7f13\u51b2\u6c34\u7bb1\u4ea7\u54c1\u77e5\u8bc6\uff1a\u5f62\u5f0f\u3001\u6750\u8d28\u3001\u5bb9\u91cf\u4e0e\u63a5\u53e3\uff0c\u4e00\u53ea\u6876\u600e\u4e48\u9009\u600e\u4e48\u770b<\/a><\/strong>\uff1a\u7f13\u51b2\u6c34\u7bb1\u8fd9\u53ea\u6876\u672c\u8eab\u2014\u2014\u5f62\u5f0f\u3001\u6750\u8d28\u3001\u5bb9\u91cf\u4e0e\u63a5\u53e3<\/li>\n<li><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=20914\">\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05<\/a><\/strong>\uff1a\u6e29\u5dee 5\u2103 \u600e\u4e48\u628a\u4e3b\u7ba1\u63a8\u5230 De40~De63\uff0c\u9644\u65e5\u7acb\u6280\u672f\u901a\u77e5\u9009\u578b\u8868\u4e0e\u88c5\u5b8c\u81ea\u67e5<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">\u9644\u5f55\uff1a\u5173\u952e\u6570\u636e\u3001\u516c\u5f0f\u4e0e\u6838\u67e5\u6807\u8bb0<\/h2>\n<h3 class=\"wp-block-heading\">A. \u5173\u952e\u516c\u5f0f<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u516c\u5f0f<\/strong><\/td>\n<td><strong>\u7528\u9014<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Q = m \u00d7 C \u00d7 \u0394T<\/td>\n<td>\u8ba1\u7b97\u84c4\u70ed\u91cf<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u6c34\u5bb9\u91cf = \u5236\u51b7\u91cf \u00d7 3.25<\/td>\n<td>\u5f00\u5229\u624b\u518c\u53c2\u8003\u7cfb\u6570\uff08\u8212\u9002\u6027\u7a7a\u8c03\uff09\uff0c\u975e\u5f3a\u5236\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>\u7b49\u6548\u6c34\u91cf = m_\u6df7\u51dd\u571f \u00d7 (C_\u6df7\u51dd\u571f \/ C_\u6c34)<\/td>\n<td>\u5730\u6696\u84c4\u70ed\u80fd\u529b\u8ba1\u7b97<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u81ea\u7531\u4e0e\u591a\u54c1\u724c\u7ec4\u5408<\/td>\n<td>\u89c1\u7b2c\u4e09\u90e8\u5206 3.1~3.7\uff08\u672c\u518c\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">B. \u672f\u8bed\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u672f\u8bed<\/strong><\/td>\n<td><strong>\u89e3\u91ca<\/strong><\/td>\n<\/tr>\n<tr>\n<td>COP<\/td>\n<td>\u80fd\u6548\u6bd4<\/td>\n<\/tr>\n<tr>\n<td>IPLV<\/td>\n<td>\u7efc\u5408\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u6bd4<\/td>\n<\/tr>\n<tr>\n<td>S\u503c<\/td>\n<td>PPR\u7ba1\u7cfb\u5217\u503c\uff0cS3.2\/S4\/S5\uff0c\u8d8a\u5c0f\u58c1\u8d8a\u539a<\/td>\n<\/tr>\n<tr>\n<td>PP-RCT<\/td>\n<td>\u8010\u70ed\u589e\u5f3a\u578b\u65e0\u89c4\u5171\u805a\u805a\u4e19\u70ef<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">C. \u4ea4\u53c9\u5f15\u7528\u7d22\u5f15<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4e3b\u9898<\/strong><\/td>\n<td><strong>\u672c\u624b\u518c\u4f4d\u7f6e<\/strong><\/td>\n<td><strong>\u8be6\u7ec6\u5185\u5bb9\u53c2\u89c1<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u6c1f\u5730\u6c34vs\u5929\u6c34\u5730\u6c34\u5bf9\u6bd4<\/td>\n<td>\u7b2c\u4e8c\u90e8\u5206 2.1~2.7<\/td>\n<td><strong>01\u53f7\u624b\u518c<\/strong> \u7b2c\u56db\u90e8\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u8d85\u914d\u7387\u516d\u7ef4\u5ea6\u5206\u6790<\/td>\n<td>\u2014<\/td>\n<td><strong>01\u53f7\u624b\u518c<\/strong> 3.5<\/td>\n<\/tr>\n<tr>\n<td>\u963b\u6c27\u7ba1\u6df1\u5ea6\u89e3\u6790<\/td>\n<td>\u7b2c\u516d\u90e8\u5206 6.6<\/td>\n<td><strong>02\u53f7\u624b\u518c<\/strong> 4.1<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u8def\u6c34\u529b\u5e73\u8861\u8bbe\u8ba1<\/td>\n<td>\u2014<\/td>\n<td><strong>02\u53f7\u624b\u518c<\/strong> 2.2<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u81ea\u7531\u4e0e\u591a\u54c1\u724c\u7ec4\u5408<\/td>\n<td>\u7b2c\u4e09\u90e8\u5206 3.1~3.7<\/td>\n<td>\u672c\u518c<\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u4e24\u8054\u4f9b\u5347\u7ea7\uff09<\/td>\n<td>\u2014<\/td>\n<td><strong>04\u53f7\u624b\u518c<\/strong> \u5168\u518c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n<p class=\"lm-inbound\">\u8fd8\u6ca1\u51b3\u5b9a\u88c5\u4e0d\u88c5\uff1f\u5148\u770b\u8fd9\u4e00\u9875\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=18698\">\u6211\u5bb6\u9002\u4e0d\u9002\u5408\u4e24\u8054\u4f9b\uff0c\u5148\u770b\u8fd9\u4e94\u6837<\/a>\u3002<\/p>\n<style>.lm-casepick{margin:26px 0;padding:16px 20px;background:#f5f7fb;border:1px solid #e3e8f0;border-left:4px solid #1a3a6e;border-radius:6px;}.lm-casepick h2{color:#1a3a6e;border:none;margin:0 0 10px;font-size:19px;}.lm-casepick li{margin:6px 0;}.lm-casepick a{color:#c0392b;}.lm-casepick .lm-note{color:#777;font-size:13px;}<\/style>\n<div class=\"lm-casepick\">\n<h2>\u7cbe\u9009\u4e24\u8054\u4f9b\u4ea4\u4ed8\u6848\u4f8b<\/h2>\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=11713\">\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f<\/a><span class=\"lm-note\"> \u2014 \u5957\u4e09\u5e73\u5c42 \u00b7 \u5929\u6c34\u5730\u6c34 \u00b7 \u5b8c\u5de5\u5b9e\u666f<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=7862\">\u6210\u90fd\u6210\u534e\u8a89\u6d6a\u4e1c\u671bB\u533a\uff5c\u65e5\u7acb\u6c34\u5885\u9002\u7a7a\u8c03\u5730\u6696\u4e00\u4f53\u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u8a89\u6d6a\u4e1c\u671bB\u533a \u00b7 \u7a7a\u8c03\u5730\u6696\u4e00\u4f53<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=2665\">\u6210\u90fd\u53cc\u6d41\u851a\u84dd\u5361\u5730\u4e9a\u851a\u84dd\u8f69 170\u33a1\u5b55\u5988\u65e5\u7acb\u4e24\u8054\u4f9b\u5168\u5c4b\u8212\u9002\u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u851a\u84dd\u5361\u5730\u4e9a 170\u33a1 \u00b7 \u6bcd\u5a74\u5bb6\u5ead<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=9918\">\u6210\u90fd\u5e02\u9526\u6c5f\u533a\u7fe1\u7fe0\u57ce5\u671f\u738b\u8001\u5e08\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u7efc\u5408\u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u7fe1\u7fe0\u57ce5\u671f \u00b7 \u6c34\u5885\u9002\u7efc\u5408<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=8164\">\u805a\u4ebf\u5e9c \u00b7\u00a0\u59da\u8001\u5e08\u65e5\u7acb\u667a\u4eab\u4e24\u8054\u4f9b \u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u805a\u4ebf\u5e9c \u00b7 \u667a\u4eab\u7cfb\u7edf<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=10462\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u4fdd\u5229\u5929\u7a7a\u4e4b\u57ce\u4e91\u7405\u65bd\u8001\u5e08\u65e5\u7acb\u6c34\u5885\u9002VF125\u53cc\u673a 300\u33a1\u5927\u5b85\u4e24\u8054\u4f9b\u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u4fdd\u5229\u5929\u7a7a\u4e4b\u57ce\u4e91\u7405 \u00b7 VF125\u53cc\u673a \u00b7 300\u33a1\u5927\u5b85<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=8769\">\u65ed\u8f89\u6c5f\u5c71\u9662\uff5c\u65b0\u6d25\u8054\u6392\u65e5\u7acb\u6c34\u5885\u9002\u53cc\u673a\u4e24\u8054\u4f9b\u5b8c\u5de5\u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u65b0\u6d25\u8054\u6392 \u00b7 \u53cc\u673a\u4e24\u8054\u4f9b<\/span><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12733\">\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u81ea\u5efa\u623f\uff5c\u65e5\u7acb\u6c34\u5885\u9002\u4e8c\u8054\u4f9b\u5b9e\u6d4b\u6848\u4f8b<\/a><span class=\"lm-note\"> \u2014 \u5927\u6797\u9547\u81ea\u5efa\u623f \u00b7 \u5b9e\u6d4b\u6570\u636e<\/span><\/li>\n<\/ul>\n<\/div>\n<h2 class=\"wp-block-heading\">\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p class=\"wp-block-paragraph\">\u4e24\u8054\u4f9b\u8981\u4e0d\u8981\u4e0a\u3001\u6c34\u6a21\u5757\u653e\u54ea\u513f\u3001\u5730\u6696\u548c\u7a7a\u8c03\u600e\u4e48\u5206\uff0c\u90fd\u5f97\u770b\u7740\u623f\u5b50\u7b97\u3002\u624b\u518c\u91cc\u5bf9\u4e0a\u4e86\u4f60\u5bb6\u7684\u60c5\u51b5\uff0c\u53ef\u4ee5\u76f4\u63a5\u627e\u6211\u4eec\u804a\uff1b\u6210\u90fd\u4e3b\u57ce\u53ca\u5468\u8fb9\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u770b\u5b8c\u73b0\u573a\u518d\u8c08\u65b9\u6848\u3002<\/p>\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95e8\u5e97<\/strong><\/td>\n<td><strong>\u5730\u5740<\/strong><\/td>\n<td><strong>\u7535\u8bdd<\/strong><\/td>\n<td><strong>\u5bfc\u822a<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/td>\n<td>\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B \/ A348<\/td>\n<td><a href=\"tel:02886131795\">028-86131795<\/a><\/td>\n<td><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/td>\n<td>\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<\/td>\n<td><a href=\"tel:02865272586\">028-65272586<\/a><\/td>\n<td><a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"wp-block-paragraph\">\u4e24\u5bb6\u95e8\u5e97\u90fd\u5728\u6210\u90fd\u5bcc\u68ee\u7f8e\u5bb6\u5c45\uff0c\u53ef\u4ee5\u76f4\u63a5\u5230\u5e97\u770b\u5b9e\u7269\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8425\u4e1a\u65f6\u95f4<\/strong>\uff1a\u5468\u4e00\u5230\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u5468\u65e5 10:00\u201319:00\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u9500\u552e\u987e\u95ee<\/strong>\uff1a\u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a>\uff1b\u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a>\u3002<\/p>\n<section style=\"margin:28px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0;font-size:15px;line-height:1.8;color:#1a1a1a;\">\u60f3\u7cfb\u7edf\u8bfb\u5b8c\u9f99\u8109\u6696\u901a\u7684\u5168\u90e8\u6280\u672f\u5185\u5bb9\uff1f\u56de\u5230 <a href=\"https:\/\/longmai-nt.com\/?page_id=16039\" style=\"color:#c25a1f;font-weight:700;text-decoration:none;\">\u9f99\u8109\u6696\u901a\u767d\u76ae\u4e66\u4e2d\u5fc3<\/a>\uff0c\u96c6\u4e2d\u83b7\u53d6 17 \u672c\u767d\u76ae\u4e66\u4e0e\u56db\u672c\u6280\u672f\u624b\u518c\u3002<\/p>\n<\/section>\n<section style=\"margin:20px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0 0 10px;font-size:15px;font-weight:700;color:#12314F;\">\u5ef6\u4f38\u9605\u8bfb \u00b7 \u9f99\u8109\u6696\u901a\u6280\u672f\u4f53\u7cfb<\/p>\n<p style=\"margin:0;font-size:14px;line-height:2.2;\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009\uff5c\u6c1f\u673a\u9009\u578b\u3001\u5b89\u88c5\u9a8c\u6536\u4e0e\u552e\u540e\u5168\u89e3<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13292\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u767d\u76ae\u4e66<\/a>\n<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u7248\u672c\uff1aV2.5 \u7f16\u5236\u65e5\u671f\uff1a2026\u5e7410 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-671","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u4e24\u8054\u4f9b\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\uff1a\u667a\u4eab AQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff1b\u5c0a\u777f\u5168\u6548\u2161 \u914d\u4e09\u7ba1\u5236\u5185\u673a\u505a\u6e29\u6e7f\u53cc\u63a7\uff0c\u522b\u5885\u673a\u8d70\u4e24\u7ba1\u5236\u3002\u56db\u79cd\u914d\u6cd5\u7684\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u8d85\u914d\u7387\u4e0a\u9650\u3001\u9002\u7528\u9762\u79ef\u548c\u65bd\u5de5\u8981\u70b9\u90fd\u5728\u8fd9\u672c\u91cc\uff0c\u578b\u53f7\u53e3\u5f84\u4ee5\u5382\u5bb6\u6837\u518c\u4e3a\u51c6\u3002\u6210\u90fd\u9009\u578b\u6309\u8fd9\u4e00\u518c\u7684\u53e3\u5f84\u5b9a\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=671\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u4e24\u8054\u4f9b\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\uff1a\u667a\u4eab AQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff1b\u5c0a\u777f\u5168\u6548\u2161 \u914d\u4e09\u7ba1\u5236\u5185\u673a\u505a\u6e29\u6e7f\u53cc\u63a7\uff0c\u522b\u5885\u673a\u8d70\u4e24\u7ba1\u5236\u3002\u56db\u79cd\u914d\u6cd5\u7684\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u8d85\u914d\u7387\u4e0a\u9650\u3001\u9002\u7528\u9762\u79ef\u548c\u65bd\u5de5\u8981\u70b9\u90fd\u5728\u8fd9\u672c\u91cc\uff0c\u578b\u53f7\u53e3\u5f84\u4ee5\u5382\u5bb6\u6837\u518c\u4e3a\u51c6\u3002\u6210\u90fd\u9009\u578b\u6309\u8fd9\u4e00\u518c\u7684\u53e3\u5f84\u5b9a\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=671\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T10:06:12+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671\",\"name\":\"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-13T09:20:19+00:00\",\"dateModified\":\"2026-11-21T10:06:12+00:00\",\"description\":\"\u4e24\u8054\u4f9b\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\uff1a\u667a\u4eab AQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff1b\u5c0a\u777f\u5168\u6548\u2161 \u914d\u4e09\u7ba1\u5236\u5185\u673a\u505a\u6e29\u6e7f\u53cc\u63a7\uff0c\u522b\u5885\u673a\u8d70\u4e24\u7ba1\u5236\u3002\u56db\u79cd\u914d\u6cd5\u7684\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u8d85\u914d\u7387\u4e0a\u9650\u3001\u9002\u7528\u9762\u79ef\u548c\u65bd\u5de5\u8981\u70b9\u90fd\u5728\u8fd9\u672c\u91cc\uff0c\u578b\u53f7\u53e3\u5f84\u4ee5\u5382\u5bb6\u6837\u518c\u4e3a\u51c6\u3002\u6210\u90fd\u9009\u578b\u6309\u8fd9\u4e00\u518c\u7684\u53e3\u5f84\u5b9a\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","description":"\u4e24\u8054\u4f9b\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\uff1a\u667a\u4eab AQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff1b\u5c0a\u777f\u5168\u6548\u2161 \u914d\u4e09\u7ba1\u5236\u5185\u673a\u505a\u6e29\u6e7f\u53cc\u63a7\uff0c\u522b\u5885\u673a\u8d70\u4e24\u7ba1\u5236\u3002\u56db\u79cd\u914d\u6cd5\u7684\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u8d85\u914d\u7387\u4e0a\u9650\u3001\u9002\u7528\u9762\u79ef\u548c\u65bd\u5de5\u8981\u70b9\u90fd\u5728\u8fd9\u672c\u91cc\uff0c\u578b\u53f7\u53e3\u5f84\u4ee5\u5382\u5bb6\u6837\u518c\u4e3a\u51c6\u3002\u6210\u90fd\u9009\u578b\u6309\u8fd9\u4e00\u518c\u7684\u53e3\u5f84\u5b9a\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=671","og_locale":"zh_CN","og_type":"article","og_title":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","og_description":"\u4e24\u8054\u4f9b\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\uff1a\u667a\u4eab AQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff1b\u5c0a\u777f\u5168\u6548\u2161 \u914d\u4e09\u7ba1\u5236\u5185\u673a\u505a\u6e29\u6e7f\u53cc\u63a7\uff0c\u522b\u5885\u673a\u8d70\u4e24\u7ba1\u5236\u3002\u56db\u79cd\u914d\u6cd5\u7684\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u8d85\u914d\u7387\u4e0a\u9650\u3001\u9002\u7528\u9762\u79ef\u548c\u65bd\u5de5\u8981\u70b9\u90fd\u5728\u8fd9\u672c\u91cc\uff0c\u578b\u53f7\u53e3\u5f84\u4ee5\u5382\u5bb6\u6837\u518c\u4e3a\u51c6\u3002\u6210\u90fd\u9009\u578b\u6309\u8fd9\u4e00\u518c\u7684\u53e3\u5f84\u5b9a\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=671","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-21T10:06:12+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=671","url":"https:\/\/longmai-nt.com\/?page_id=671","name":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-13T09:20:19+00:00","dateModified":"2026-11-21T10:06:12+00:00","description":"\u4e24\u8054\u4f9b\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u5206\uff1a\u667a\u4eab AQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff1b\u5c0a\u777f\u5168\u6548\u2161 \u914d\u4e09\u7ba1\u5236\u5185\u673a\u505a\u6e29\u6e7f\u53cc\u63a7\uff0c\u522b\u5885\u673a\u8d70\u4e24\u7ba1\u5236\u3002\u56db\u79cd\u914d\u6cd5\u7684\u5916\u673a\u578b\u53f7\u3001\u6c34\u6a21\u5757\u6863\u4f4d\u3001\u8d85\u914d\u7387\u4e0a\u9650\u3001\u9002\u7528\u9762\u79ef\u548c\u65bd\u5de5\u8981\u70b9\u90fd\u5728\u8fd9\u672c\u91cc\uff0c\u578b\u53f7\u53e3\u5f84\u4ee5\u5382\u5bb6\u6837\u518c\u4e3a\u51c6\u3002\u6210\u90fd\u9009\u578b\u6309\u8fd9\u4e00\u518c\u7684\u53e3\u5f84\u5b9a\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=671#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=671"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=671#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/671","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=671"}],"version-history":[{"count":24,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/671\/revisions"}],"predecessor-version":[{"id":21100,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/671\/revisions\/21100"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=671"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}