{"id":673,"date":"2026-05-13T17:22:57","date_gmt":"2026-05-13T09:22:57","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=673"},"modified":"2026-11-21T18:21:00","modified_gmt":"2026-11-21T10:21:00","slug":"04_%e4%ba%94%e6%81%92%e2%81%ba%e7%b3%bb%e7%bb%9f%ef%bc%88%e5%85%a8%e5%b1%8b%e5%85%a8%e6%84%9f%ef%bc%89%c2%b7-%e6%8a%80%e6%9c%af%e6%bc%94%e8%bf%9b%e4%b8%8e%e5%ae%9e%e6%88%98%e6%89%8b%e5%86%8c","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=673","title":{"rendered":"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c"},"content":{"rendered":"<div class=\"lm-geo\" data-book=\"NT04\" data-cat=\"\u4e94\u6052\" data-layer=\"\u6839\" data-code=\"NT04\" data-step=\"1\" data-elem=\"\" data-q=\"\u4e94\u6052\u7cfb\u7edf\u5230\u5e95\u662f\u4ec0\u4e48\u3001\u503c\u4e0d\u503c\u5f97\u88c5\"><\/div>\n<\/div>\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c<\/strong>\uff1aV2.3<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e7410\u670824\u65e5<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7f16\u5236\u8bf4\u660e<\/strong>\uff1a\u672c\u624b\u518c\u4e3a\u9f99\u8109\u6696\u901a\u6280\u672f\u624b\u518c\u7cfb\u5217<strong>\u7b2c04\u53f7<\/strong>\uff0c\u6574\u5408\u4e94\u6052\u207a\u7cfb\u7edf\u7684\u5168\u90e8\u5185\u5bb9\uff0c\u6db5\u76d6\u6280\u672f\u539f\u7406\u3001\u6838\u5fc3\u5b50\u7cfb\u7edf\u3001\u8bbe\u8ba1\u89c4\u8303\u3001\u4ea7\u54c1\u77e9\u9635\u3001\u5b9e\u6218\u6848\u4f8b\u3001\u552e\u540e\u7ef4\u4fdd\u516d\u5927\u677f\u5757\u3002\u672c\u624b\u518c\u662f01-03\u53f7\u624b\u518c\u7684\u8fdb\u9636\u5ef6\u4f38\uff0c\u4ece\u4e24\u8054\u4f9b\u5347\u7ea7\u5230\u5168\u7ef4\u7a7a\u6c14\u7ba1\u7406\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u3010\u672c\u7cfb\u5217\u624b\u518c\u8bf4\u660e\u3011<\/h2>\n<p class=\"wp-block-paragraph\">\u672c\u624b\u518c\u4e3a<strong>\u9f99\u8109\u6696\u901a\u6280\u672f\u624b\u518c\u7cfb\u5217\u7b2c 04 \u53f7<\/strong>\uff0c\u5168\u5957\u5171 4 \u518c\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5e8f\u53f7<\/strong><\/td>\n<td><strong>\u540d\u79f0<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>01<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=667\">\u300a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u6c1f\u673a\u539f\u7406\u3001\u4ea7\u54c1\u5bf9\u4f4d\u3001\u538b\u7f29\u673a\u9009\u578b\u3001\u4e09\u7ba1\u5236<\/td>\n<\/tr>\n<tr>\n<td><strong>02<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=669\">\u300a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u71c3\u6c14\u70ed\u6e90\u3001\u5730\u6696\u4e0e\u6696\u6c14\u7247\u672b\u7aef\u3001\u7ba1\u8def\u8bbe\u8ba1\u3001\u6c34\u529b\u5e73\u8861\u3001\u751f\u6d3b\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td><strong>03<\/strong><\/td>\n<td><a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u300a\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a><\/td>\n<td>\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u4e09\u8054\u4f9b\uff0c\u56db\u79cd\u914d\u6cd5\u600e\u4e48\u9009<\/td>\n<\/tr>\n<tr>\n<td><strong>04<\/strong><\/td>\n<td><strong>\u300a\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b\uff08\u672c\u9875\uff09<\/strong><\/td>\n<td>\u6e29\u6e7f\u6c27\u6d01\u9759\u4e94\u7ef4\u3001\u5168\u5c4b\u5168\u611f 3.0\u3001\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">\u8fd9\u4e00\u518c\u548c\u767d\u76ae\u4e66\u662f\u4ec0\u4e48\u5173\u7cfb<\/h3>\n<p class=\"wp-block-paragraph\">\u4e0d\u662f\u4e24\u672c\u5e76\u5217\u7684\u4e66\uff0c\u662f\u4e0a\u4e0b\u4e24\u5c42\uff1a<strong>\u767d\u76ae\u4e66\u662f\u77e5\u8bc6\u5e95\u5ea7\uff0c\u8fd9\u4e00\u518c\u662f\u4ece\u77e5\u8bc6\u5e95\u5ea7\u91cc\u5206\u51fa\u6765\u7684\u6267\u884c\u5206\u518c\u3002<\/strong><\/p>\n<p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=13292\">\u300a\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u767d\u76ae\u4e66\u300b<\/a>\u662f\u77e5\u8bc6\u5e95\u5ea7\uff0c\u4e5f\u662f\u8fd9\u4e00\u518c\u7684\u4e0a\u4e00\u5c42\u3002<\/strong>\u5b83\u628a\u4e94\u6052\u8fd9\u4ef6\u4e8b\u7684\u77e5\u8bc6\u94fa\u5168\u3001\u8bb2\u900f\u2014\u2014\u4e94\u6052\u5230\u5e95\u662f\u4ec0\u4e48\u3001\u4e94\u4e2a\u6307\u6807\u6309\u54ea\u4e2a\u6807\u51c6\u5b9a\u3001\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u5206\u3001\u4e3b\u673a\u548c\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u8bbe\u8ba1\u53c2\u6570\u53d6\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\u3001\u5927\u6982\u8981\u82b1\u591a\u5c11\u94b1\u3001\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u957f\u4ec0\u4e48\u6837\u3002\u77e5\u8bc6\u5e95\u5ea7\u8981\u7684\u5c31\u662f\u5e7f\u5ea6\u548c\u6df1\u5ea6\uff0c\u4e0d\u6015\u8bb2\u591a\u3001\u4e0d\u6015\u8bb2\u7ec6\uff1a\u770b\u5b8c\u5b83\uff0c\u4f60\u624b\u4e0a\u6709\u4e00\u5957\u5b8c\u6574\u7684\u5224\u65ad\u4f9d\u636e\uff0c\u80fd\u81ea\u5df1\u5224\u65ad<strong>\u300c\u8981\u4e0d\u8981\u505a\u300d<\/strong>\uff0c\u4e5f\u80fd\u542c\u61c2\u4efb\u4f55\u4e00\u4e2a\u9500\u552e\u5728\u8ddf\u4f60\u8bb2\u4ec0\u4e48\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u4e00\u518c\u662f\u6267\u884c\u5206\u518c\uff0c\u89e3\u51b3\u300c\u600e\u4e48\u505a\u300d\u3002<\/strong>\u540c\u4e00\u4e2a\u77e5\u8bc6\u5e95\u5ea7\uff0c\u843d\u5230\u5177\u4f53\u9879\u76ee\u4e0a\u4f1a\u5206\u5c94\uff1a\u9009\u54ea\u6761\u8def\u7ebf\u3001\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u673a\u5668\u600e\u4e48\u914d\u3001\u7ba1\u5f84\u548c\u7ba1\u8def\u600e\u4e48\u8d70\u3001\u9a8c\u6536\u67e5\u54ea\u51e0\u9879\u3001\u9664\u6e7f\u91cf\u4e0d\u591f\u4ece\u54ea\u4e0b\u624b\u3001\u51fa\u4e86\u95ee\u9898\u600e\u4e48\u6392\u3002\u8fd9\u4e9b\u4e0d\u662f\u5224\u65ad\uff0c\u662f\u64cd\u4f5c\u2014\u2014\u767d\u76ae\u4e66\u7ed9\u65b9\u5411\u548c\u4f9d\u636e\uff0c\u8fd9\u4e00\u518c\u7ed9\u505a\u6cd5\u548c\u5224\u636e\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e24\u5c42\u4e00\u53e5\u8bdd\uff1a\u767d\u76ae\u4e66\u7ba1\u300c\u8981\u4e0d\u8981\u505a\u300d\uff0c\u8fd9\u4e00\u518c\u7ba1\u300c\u600e\u4e48\u505a\u3001\u505a\u5f97\u5bf9\u4e0d\u5bf9\u300d\u3002<\/strong>\u8fd8\u6ca1\u641e\u6e05\u4e94\u6052\u662f\u4ec0\u4e48\u7684\uff0c\u5148\u53bb\u767d\u76ae\u4e66\uff0c\u628a\u5224\u65ad\u4f9d\u636e\u62ff\u5168\uff1b\u51b3\u5b9a\u8981\u505a\u4e86\uff0c\u56de\u6765\u6309\u8fd9\u4e00\u518c\u5f80\u4e0b\u8d70\u3002\u8fd9\u4e00\u518c\u4ece 1.1 \u5f00\u59cb\u5c31\u5047\u5b9a\u4f60\u5df2\u7ecf\u77e5\u9053\u4e94\u6052\u5927\u6982\u662f\u4ec0\u4e48\uff0c\u4e0d\u518d\u89e3\u91ca\u6982\u5ff5\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u672c\u518c\u7ba1\u4ec0\u4e48\uff0c\u4e0d\u7ba1\u4ec0\u4e48<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u7ba1<\/strong>\uff1a\u4e94\u6052\u8fd9\u4e2a\u7cfb\u7edf\u600e\u4e48\u6210\u7acb\u2014\u2014\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001\u542b\u6c27\u91cf\u3001\u6d01\u51c0\u5ea6\u3001\u566a\u97f3\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u7684\u6307\u6807\u4e0e\u505a\u6cd5\uff0c\u5168\u7a7a\u6c14\u3001\u8f90\u5c04\u3001\u590d\u5408\u5f0f\u4e09\u6761\u6280\u672f\u8def\u7ebf\u600e\u4e48\u5206\uff0c\u65e5\u7acb\u5168\u5c4b\u5168\u611f 3.0 \u7684\u67b6\u6784\uff0c\u8bbe\u8ba1\u53c2\u6570\u3001\u65bd\u5de5\u9a8c\u6536\u3001\u9632\u7ed3\u9732\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u7ba1<\/strong>\uff1a\u4e3b\u673a\u4e0e\u51b7\u70ed\u6e90\u600e\u4e48\u914d\u3001\u5929\u6c1f\u5730\u6c34\u8fd8\u662f\u5929\u6c34\u5730\u6c34\u3001\u6c34\u6a21\u5757\u600e\u4e48\u9009\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=671\">03 \u53f7\u624b\u518c\u300a\u4e24\u8054\u4f9b\u300b<\/a>\u3002\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\u3001\u4e3b\u7ba1\u7ba1\u5f84\u3001\u5206\u96c6\u6c34\u5668\u3001\u6c34\u529b\u5e73\u8861\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=669\">02 \u53f7\u624b\u518c<\/a>\u3002\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u672c\u4f53\u4e0e\u4e09\u7ba1\u5236\u2014\u2014\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=667\">01 \u53f7\u624b\u518c<\/a>\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5177\u4f53\u5230\u67d0\u4e00\u53f0\u673a\u5668\u7684\u5916\u673a\u5c3a\u5bf8\u3001\u63a5\u7ba1\u53e3\u5f84\u3001\u9010\u9879\u53c2\u6570\uff0c\u672c\u518c\u4e5f\u4e0d\u590d\u8ff0\uff1a\u5929\u6c1f\u5730\u6c34\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u300a\u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u8be6\u60c5\u9875\u300b<\/a>\uff0c\u5929\u6c34\u5730\u6c34\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u300a\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66\u300b<\/a>\u3002\u672c\u518c\u7ba1\u5230\u300c\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u300d\u8fd9\u4e00\u5c42\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u4e3a\u4ec0\u4e48\u4e94\u6052\u6392\u5728\u7b2c\u56db<\/h3>\n<p class=\"wp-block-paragraph\">\u56e0\u4e3a\u5b83\u662f\u524d\u4e09\u518c\u7684\u52a0\u6cd5\uff0c\u4e0d\u662f\u66ff\u4ee3\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e00\u53f0\u4e3b\u673a\u3001\u4e00\u5957\u6c34\u8def\u3001\u4e00\u5957\u98ce\u8def\u300201 \u53f7\u624b\u518c\u8bb2\u4e3b\u673a\u600e\u4e48\u9009\uff0c02 \u53f7\u624b\u518c\u8bb2\u6c34\u5f80\u54ea\u513f\u9001\u3001\u5730\u6696\u600e\u4e48\u94fa\uff0c03 \u53f7\u624b\u518c\u8bb2\u8fd9\u5957\u6c34\u600e\u4e48\u5206\u6210\u4e24\u8054\u4f9b\u7684\u56db\u6761\u8def\u3002\u4e94\u6052\u662f\u5728\u8fd9\u5957\u5e95\u5b50\u4e0a\u518d\u53e0\u4e00\u5c42\uff1a\u628a\u300c\u6e29\u5ea6\u591f\u4e86\u300d\u53d8\u6210\u300c\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001\u542b\u6c27\u91cf\u3001\u6d01\u51c0\u5ea6\u3001\u566a\u97f3\u4e94\u4e2a\u90fd\u591f\u300d\uff0c\u800c\u4e14\u4e94\u4e2a\u8981\u540c\u65f6\u6210\u7acb\u3001\u4e92\u76f8\u4e0d\u6253\u67b6\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u6240\u4ee5\u4e94\u6052\u96be\u7684\u5730\u65b9\u4e0d\u5728\u8bbe\u5907\u6e05\u5355\uff0c\u5728\u5e73\u8861\u3002\u964d\u6e7f\u4f1a\u987a\u5e26\u964d\u6e29\uff0c\u964d\u591a\u4e86\u4eba\u4e0d\u8212\u670d\uff1b\u65b0\u98ce\u91cf\u5f00\u5927\u4e86\u566a\u97f3\u4e0a\u6765\uff0c\u5f00\u5c0f\u4e86 CO\u2082 \u538b\u4e0d\u4f4f\uff1b\u8f90\u5c04\u677f\u6c34\u6e29\u9ad8\u4e86\u4e0d\u591f\u51b7\uff0c\u4f4e\u4e86\u5c31\u7ed3\u9732\u3002\u4e94\u4e2a\u6307\u6807\u5f7c\u6b64\u62c9\u626f\uff0c\u672c\u518c\u7b2c\u4e8c\u90e8\u5206\u8bb2\u6bcf\u4e2a\u7ef4\u5ea6\u600e\u4e48\u5b9a\u6807\u51c6\uff0c\u7b2c\u4e5d\u90e8\u5206\u8bb2\u8fd9\u4e9b\u62c9\u626f\u5728\u73b0\u573a\u600e\u4e48\u89e3\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u4e94\u6052\u8ddf\u4e24\u8054\u4f9b\uff0c\u5dee\u7684\u4e0d\u662f\u8bbe\u5907\u6e05\u5355<\/h3>\n<p class=\"wp-block-paragraph\">\u5e38\u6709\u5ba2\u6237\u95ee\uff1a\u88c5\u4e2a\u4e24\u8054\u4f9b\uff0c\u518d\u52a0\u4e00\u53f0\u65b0\u98ce\uff0c\u4e0d\u5c31\u662f\u4e94\u6052\u4e86\uff1f\u4ece\u8bbe\u5907\u6e05\u5355\u770b\u5dee\u4e0d\u591a\uff0c\u4ece\u9a8c\u6536\u770b\u5dee\u5f88\u8fdc\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u4e24\u8054\u4f9b\u89e3\u51b3\u7684\u662f\u300c\u590f\u5929\u6709\u51b7\u3001\u51ac\u5929\u6709\u70ed\u300d\uff0c\u9a8c\u6536\u770b\u51b7\u70ed\u91cf\u591f\u4e0d\u591f\u3001\u6c34\u6e29\u5bf9\u4e0d\u5bf9\u3002\u4e94\u6052\u89e3\u51b3\u7684\u662f\u300c\u8fd9\u4e94\u4e2a\u6570\u5e38\u5e74\u7a33\u5728\u533a\u95f4\u91cc\u300d\uff0c\u9a8c\u6536\u770b\u8fde\u7eed\u51e0\u5929\u7684\u5b9e\u6d4b\u66f2\u7ebf\u2014\u2014\u6e29\u5ea6\u6ce2\u52a8\u591a\u5927\u3001\u6e7f\u5ea6\u6709\u6ca1\u6709\u51b2\u51fa\u53bb\u3001CO\u2082 \u5cf0\u503c\u591a\u5c11\u3001\u98ce\u53e3\u566a\u97f3\u51e0\u5206\u8d1d\u3002\u672c\u518c\u9644\u5f55 B \u628a\u8fd9\u51e0\u9879\u7684\u53d6\u503c\u5217\u6210\u4e86\u901f\u67e5\u8868\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u5dee\u522b\u7684\u6839\u5b50\u5728\u63a7\u5236\u3002\u4e24\u8054\u4f9b\u662f\u5404\u7ba1\u5404\u7684\uff1a\u7a7a\u8c03\u7ba1\u6e29\u5ea6\u3001\u65b0\u98ce\u7ba1\u6362\u6c14\u3001\u9664\u6e7f\u673a\u7ba1\u6e7f\u5ea6\uff0c\u4e09\u5957\u7cfb\u7edf\u5404\u81ea\u4e3a\u653f\uff0c\u4e2d\u95f4\u90a3\u4e00\u6bb5\u6ca1\u4eba\u534f\u8c03\u3002\u4e94\u6052\u662f\u7531\u4e00\u4e2a\u5e73\u53f0\u540c\u65f6\u8c03\u5ea6\u51e0\u5957\u672b\u7aef\uff0c\u6e7f\u5ea6\u4e0a\u53bb\u4e86\u5148\u8c03\u9664\u6e7f\u3001\u6e29\u5ea6\u4e0d\u7528\u8ddf\u7740\u5f80\u4e0b\u6389\u2014\u2014\u8fd9\u5c31\u662f\u672c\u518c 4.6 \u8bb2\u7684\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\u3002\u6ca1\u6709\u8fd9\u4e00\u5c42\uff0c\u8bbe\u5907\u5806\u5f97\u518d\u9f50\uff0c\u9a8c\u6536\u65f6\u4e5f\u53ea\u662f\u300c\u4e24\u8054\u4f9b\u52a0\u65b0\u98ce\u300d\u3002<\/p>\n<p class=\"wp-block-paragraph\">\u53cd\u8fc7\u6765\u4e5f\u4e00\u6837\uff1a\u60f3\u628a\u4e94\u6052\u505a\u597d\uff0c\u4e3b\u673a\u90a3\u4e00\u7aef\u5fc5\u987b\u914d\u5f97\u5bf9\u3002\u56db\u79cd\u914d\u6cd5\u5404\u81ea\u7684\u9002\u7528\u9762\u79ef\u3001\u6c34\u6a21\u5757\u600e\u4e48\u9009\u3001\u4e09\u7ba1\u5236\u5ba4\u5185\u673a\u80fd\u914d\u54ea\u79cd\u5916\u673a\uff0c\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=671\">03 \u53f7\u624b\u518c\u300a\u4e24\u8054\u4f9b\u300b<\/a>\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u600e\u4e48\u8bfb\u8fd9\u56db\u518c<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9605\u8bfb\u8def\u5f84\u5efa\u8bae<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>\u7b2c\u4e00\u6b21\u63a5\u89e6\u4e94\u6052<\/strong>\uff1a\u5148\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=13292\">\u300a\u4e94\u6052\u207a\u7cfb\u7edf\u767d\u76ae\u4e66\u300b<\/a>\uff0c\u628a\u300c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u6211\u5bb6\u8be5\u4e0d\u8be5\u505a\u3001\u5927\u6982\u591a\u5c11\u94b1\u300d\u641e\u6e05\u695a\uff1b\u56de\u6765\u518d\u8bfb\u672c\u518c 1.1 \u4e0e 2.1 \u81f3 2.5\uff0c\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\uff0c\u8fd9\u91cc\u624d\u6709\u6570<\/li>\n<li><strong>\u6b63\u5728\u6bd4\u65b9\u6848<\/strong>\uff1a\u76f4\u63a5\u770b\u7b2c\u56db\u90e8\u5206\uff08\u6838\u5fc3\u5b50\u7cfb\u7edf\uff09\u4e0e 8.2\uff08\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff09\uff0c\u518d\u6309\u7b2c\u4e03\u90e8\u5206\u7684\u6210\u90fd\u6848\u4f8b\u5bf9\u7167\u81ea\u5bb6\u6237\u578b<\/li>\n<li><strong>\u51c6\u5907\u5f00\u5de5<\/strong>\uff1a\u7b2c\u516d\u90e8\u5206\u8bbe\u8ba1\u89c4\u8303\u4e0e\u65bd\u5de5\u9a8c\u6536\uff0c\u52a0 9.4 \u9632\u7ed3\u9732\u81ea\u68c0\u6e05\u5355<\/li>\n<li><strong>\u53ea\u5173\u5fc3\u4e24\u8054\u4f9b<\/strong>\uff1a\u53bb <a href=\"https:\/\/longmai-nt.com\/?page_id=671\">03 \u53f7\u624b\u518c<\/a>\uff0c\u672c\u518c\u53ea\u5728\u300c\u52a0\u4e86\u4e94\u6052\u4e4b\u540e\u300d\u624d\u6709\u610f\u4e49<\/li>\n<li><strong>\u53ea\u5173\u5fc3\u5730\u6696<\/strong>\uff1a\u53bb <a href=\"https:\/\/longmai-nt.com\/?page_id=669\">02 \u53f7\u624b\u518c<\/a>\uff0c\u4e94\u6052\u7684\u8f90\u5c04\u672b\u7aef\u8e29\u7684\u5c31\u662f\u90a3\u4e00\u5957\u5730\u6696\u505a\u6cd5<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u53c9\u5f15\u7528\u89c4\u5219<\/strong>\uff1a\u672c\u624b\u518c\u4e2d\u5f15\u7528\u5176\u4ed6\u624b\u518c\u5185\u5bb9\u65f6\uff0c\u4ee5\u5e8f\u53f7\u6807\u6ce8\uff08\u5982\u300c\u8be6\u89c1 03 \u53f7\u624b\u518c\u7b2c 2.1 \u8282\u300d\uff09\uff0c\u88ab\u5f15\u7528\u7684\u624b\u518c\u540d\u79f0\u90fd\u53ef\u4ee5\u70b9\u5f00\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u90e8\u5206<\/strong><\/td>\n<td><strong>\u6807\u9898<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e00\u90e8\u5206<\/strong><\/td>\n<td>\u4e94\u6052\u7cfb\u7edf\u6982\u8ff0\u4e0e\u884c\u4e1a\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e8c\u90e8\u5206<\/strong><\/td>\n<td>\u4e94\u6052\u7684\u4e94\u5927\u7ef4\u5ea6\u6df1\u5ea6\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e09\u90e8\u5206<\/strong><\/td>\n<td>\u5168\u7a7a\u6c14\u7cfb\u7edf vs \u8f90\u5c04\u7cfb\u7edf vs \u590d\u5408\u5f0f\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u56db\u90e8\u5206<\/strong><\/td>\n<td>\u6838\u5fc3\u5b50\u7cfb\u7edf\u6df1\u5ea6\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e94\u90e8\u5206<\/strong><\/td>\n<td>\u65e5\u7acb\u5168\u5c4b\u5168\u611f3.0\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u516d\u90e8\u5206<\/strong><\/td>\n<td>\u8bbe\u8ba1\u89c4\u8303\u4e0e\u65bd\u5de5\u9a8c\u6536<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e03\u90e8\u5206<\/strong><\/td>\n<td>\u5b9e\u6218\u6848\u4f8b\u6df1\u5ea6\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u516b\u90e8\u5206<\/strong><\/td>\n<td>\u5ba2\u6237\u6c9f\u901a\u4e0e\u65b9\u6848\u5448\u73b0<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b2c\u4e5d\u90e8\u5206<\/strong><\/td>\n<td>\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9644\u5f55<\/strong><\/td>\n<td>\u672f\u8bed\u901f\u67e5\u3001\u53c2\u6570\u901f\u67e5\u3001\u5e38\u89c1\u95ee\u9898\u3001\u4ea4\u53c9\u7d22\u5f15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u672c\u300a\u4e94\u6052\u207a\u5168\u5c4b\u5168\u611f\u7cfb\u7edf V2.3 \u6280\u672f\u5b9e\u6218\u624b\u518c\u300b\u4e3a\u6210\u90fd\u9f99\u8109\u6696\u901a\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u8d44\u6599\uff0c\u9002\u914d\u6210\u90fd\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u3001\u851a\u84dd\u5361\u5730\u4e9a\u3001\u548c\u8d35\u5357\u5c71\u3001\u5927\u6797\u9547\u7b49\u672c\u5730\u5927\u5e73\u5c42\u3001\u53e0\u62fc\u3001\u81ea\u5efa\u623f\u6237\u578b\uff1b\u9488\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\u9ad8\u6e7f\u6c14\u5019\u5b9a\u5236\u72ec\u7acb\u9664\u6e7f\u4e94\u6052\u65b9\u6848\uff0c\u8986\u76d6\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u590d\u5408\u4e94\u6052\u4e24\u5927\u65e5\u7acb\u5168\u7cfb\u673a\u578b\uff0c\u5305\u542b\u5b8c\u6574\u8bbe\u8ba1\u89c4\u8303\u3001\u65bd\u5de5\u9a8c\u6536\u6807\u51c6\u3001\u6210\u90fd\u672c\u5730\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u9ad8\u65b0\u533a\u3001\u6210\u534e\u53cc\u5bcc\u68ee\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u95e8\u5e97\u53ef\u9886\u53d6\u7eb8\u8d28\u624b\u518c\uff0c\u514d\u8d39\u4e0a\u95e8\u6237\u578b\u6d4b\u7b97\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e00\u90e8\u5206\uff1a\u4e94\u6052\u7cfb\u7edf\u6982\u8ff0\u4e0e\u884c\u4e1a\u6807\u51c6<\/h2>\n<h3 class=\"wp-block-heading\">1.1 \u4ec0\u4e48\u662f\u4e94\u6052\u7cfb\u7edf\uff1f<\/h3>\n<p class=\"wp-block-paragraph\">\u4e94\u6052\u7cfb\u7edf\u662f\u6307\u901a\u8fc7\u4e00\u5957\u96c6\u6210\u5316\u7684\u73af\u5883\u63a7\u5236\u4f53\u7cfb\uff0c\u540c\u65f6\u5b9e\u73b0\u5ba4\u5185<strong>\u6052\u6e29\u3001\u6052\u6e7f\u3001\u6052\u6c27\u3001\u6052\u6d01\u3001\u6052\u9759<\/strong>\u4e94\u5927\u7ef4\u5ea6\u7684\u6052\u5b9a\u8212\u9002\u73af\u5883\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6807\u51c6\u5b9a\u4e49<\/strong>\uff08T\/CAS 1009-2025\u300a\u667a\u6167\u4eba\u5c45\u73af\u5883\u5ba4\u5185\u4e94\u6052\u7cfb\u7edf\u5de5\u7a0b\u6280\u672f\u89c4\u8303\u300b\uff09\uff1a<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u4e94\u6052\u7cfb\u7edf\u662f\u901a\u8fc7\u7cfb\u7edf\u96c6\u6210\u800c\u667a\u80fd\u63a7\u5236\u5ba4\u5185\u70ed\u6e7f\u73af\u5883\u3001\u7a7a\u6c14\u8d28\u91cf\u548c\u566a\u58f0\u6c34\u5e73\uff0c\u4ee5\u5b9e\u73b0\u6052\u6e29\u3001\u6052\u6e7f\u3001\u6052\u6c27\u3001\u6052\u6d01\u548c\u6052\u9759\u5065\u5eb7\u8212\u9002\u6548\u679c\u7684\u5ba4\u5185\u73af\u5883\u7efc\u5408\u89e3\u51b3\u65b9\u6848\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>\u4e94\u6052\u7cfb\u7edf\u4e0e\u4f20\u7edf\u7a7a\u8c03\u7684\u672c\u8d28\u533a\u522b<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u4f20\u7edf\u7a7a\u8c03<\/strong><\/td>\n<td><strong>\u4e94\u6052\u7cfb\u7edf<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u5bf9\u8c61<\/td>\n<td>\u5355\u4e00\u6e29\u5ea6<\/td>\n<td>\u6e29\u5ea6+\u6e7f\u5ea6+\u6d01\u51c0\u5ea6+CO\u2082+\u566a\u97f3<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u6c14\u5904\u7406<\/td>\n<td>\u5c40\u90e8\u5faa\u73af<\/td>\n<td>\u5168\u5c4b\u5927\u5faa\u73af\uff08\u6362\u6c146-11\u6b21\/h\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6c14\u6d41\u7ec4\u7ec7<\/td>\n<td>\u76f4\u5439<\/td>\n<td>\u65e0\u98ce\u611f\u3001\u7f6e\u6362\u5f0f\/\u4e0a\u9001\u4e0b\u56de<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u7cfb\u7edf<\/td>\n<td>\u624b\u52a8\/\u5b9a\u65f6<\/td>\n<td>AI\u81ea\u9002\u5e94\u3001\u573a\u666f\u8054\u52a8<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u65b9\u6cd5<\/td>\n<td>\u7ecf\u9a8c\u4f30\u7b97<\/td>\n<td>\u9010\u65f6\u8d1f\u8377\u8ba1\u7b97+CFD\u6a21\u62df<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">1.2 \u4e94\u6052\u7cfb\u7edf\u7684\u6280\u672f\u6f14\u8fdb\u8def\u5f84<\/h3>\n<pre class=\"wp-block-code\"><code>\u6c1f\u7cfb\u7edf\u591a\u8054\u673a \u2192 \u4e24\u8054\u4f9b\uff08\u7a7a\u8c03+\u5730\u6696\uff09\u2192 \u4e09\u8054\u4f9b\uff08+\u751f\u6d3b\u70ed\u6c34\uff09\u2192 \u4e94\u6052\u207a\u7cfb\u7edf\uff08+\u65b0\u98ce+\u9664\u6e7f+\u52a0\u6e7f+\u51c0\u5316+\u667a\u63a7\uff09\n<\/code><\/pre>\n<h3 class=\"wp-block-heading\">1.3 \u300a\u4e2d\u56fd\u4e94\u6052\u884c\u4e1a\u53d1\u5c55\u767d\u76ae\u4e66\u300b1.0\u7248\u6838\u5fc3\u6458\u5f55<\/h3>\n<p class=\"wp-block-paragraph\"><strong>1.3.1 \u884c\u4e1a\u5b9a\u4e49\u53ca\u8303\u56f4<\/strong><\/p>\n<p class=\"wp-block-paragraph\">\u201c\u4e94\u6052\u201d\u662f\u4e2d\u56fd\u5bb6\u88c5\u6696\u901a\u884c\u4e1a\u8fd1\u51e0\u5e74\u6240\u521b\u9020\u51fa\u6765\u7684\u5e02\u573a\u5316\u540d\u8bcd\u3002\u672c\u767d\u76ae\u4e66\u7ea6\u5b9a\u201c\u4e94\u6052\u201d\u7cfb\u7edf\u4e0d\u540c\u4e8e\u4f20\u7edf\u5de5\u4e1a\u4e0a\u5e94\u7528\u7684\u201c\u6052\u6e29\u6052\u6e7f\u7a7a\u8c03\u201d\uff0c\u201c\u4e94\u6052\u201d\u7cfb\u7edf\u9996\u5148\u662f\u6253\u9020\u4e3a\u4eba\u670d\u52a1\u7684\u5ba4\u5185\u73af\u5883\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>1.3.2 \u884c\u4e1a\u53d1\u5c55\u5386\u53f2<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li><strong>2000-2010\u5e74<\/strong>\uff1a\u5fb7\u56fd\u88ab\u52a8\u623f\u7406\u5ff5\u5f15\u5165\uff1b\u5317\u4eac\u950b\u5c1a\u56fd\u9645\u516c\u5bd3\uff082003\u5e74\uff09\u9996\u6b21\u5b9e\u73b0\u8f90\u5c04\u51b7\u6696\uff1b\u6717\u8bd7\u5730\u4ea7\uff082004\u5e74\uff09\u9996\u6b21\u5c06\u201c\u4e09\u6052\u201d\u7cfb\u7edf\u5f15\u5165\u4f4f\u5b85<\/li>\n<li><strong>2011-2015\u5e74<\/strong>\uff1a\u4ece\u96c6\u4e2d\u5f0f\u201c\u4e09\u6052\u201d\u5411\u5206\u6237\u5f0f\u201c\u4e09\u6052\u201d\u8f6c\u53d8<\/li>\n<li><strong>2016-2020\u5e74<\/strong>\uff1a\u201c\u4e94\u6052\u201d\u6982\u5ff5\u51fa\u73b0\uff0c\u5168\u7a7a\u6c14\u7cfb\u7edf\u5d1b\u8d77<\/li>\n<li><strong>2021-2025\u5e74<\/strong>\uff1a\u4e13\u4e1a\u4e94\u6052\u54c1\u724c\u6d8c\u73b0\uff0c2024\u5e74\u88ab\u89c6\u4e3a\u4e2d\u56fd\u201c\u4e94\u6052\u201d\u884c\u4e1a\u5143\u5e74<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>1.3.3 \u5e02\u573a\u89c4\u6a21<\/strong><\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5e74\u4efd<\/strong><\/td>\n<td><strong>\u4f4f\u5b85\u8f90\u5c04\u4e94\u6052\u5e02\u573a<\/strong><\/td>\n<td><strong>\u5206\u6237\u5f0f\u8f90\u5c04\u4e94\u6052<\/strong><\/td>\n<\/tr>\n<tr>\n<td>2019\u5e74<\/td>\n<td>20.35\u4ebf\u5143<\/td>\n<td>3.66\u4ebf\u5143<\/td>\n<\/tr>\n<tr>\n<td>2023\u5e74<\/td>\n<td>28.97\u4ebf\u5143<\/td>\n<td>10.14\u4ebf\u5143<\/td>\n<\/tr>\n<tr>\n<td>2024\u5e74(\u9884\u8ba1)<\/td>\n<td>32.67\u4ebf\u5143<\/td>\n<td>13.29\u4ebf\u5143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">\u5168\u7a7a\u6c14\u7c7b\u4e94\u6052\u5e02\u573a\u5168\u5e74\u9500\u552e\u989d\u7ea610-15\u4ebf\u5143\u30022023\u5e74\u96c6\u6210\u5546\u5df2\u5b8c\u5de5\u9879\u76ee\u6837\u672c\u4e2d\u201c\u4e94\u6052\u201d\u7c7b\u4ec5\u53600.81%\uff0c\u4ecd\u5904\u4e8e\u5c0f\u4f17\u8d77\u6b65\u9636\u6bb5\u3002<\/p>\n<h3 class=\"wp-block-heading\">1.4 \u884c\u4e1a\u6807\u51c6\u4e0e\u89c4\u8303<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6807\u51c6\u53f7<\/strong><\/td>\n<td><strong>\u6807\u51c6\u540d\u79f0<\/strong><\/td>\n<td><strong>\u72b6\u6001<\/strong><\/td>\n<\/tr>\n<tr>\n<td>T\/CAS 1009-2025<\/td>\n<td>\u300a\u667a\u6167\u4eba\u5c45\u73af\u5883\u5ba4\u5185\u4e94\u6052\u7cfb\u7edf\u5de5\u7a0b\u6280\u672f\u89c4\u8303\u300b<\/td>\n<td>\u73b0\u884c<\/td>\n<\/tr>\n<tr>\n<td>GB 50736-2012<\/td>\n<td>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td>\n<td>\u73b0\u884c<\/td>\n<\/tr>\n<tr>\n<td>JGJ 142-2012<\/td>\n<td>\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/td>\n<td>\u73b0\u884c<\/td>\n<\/tr>\n<tr>\n<td>T\/CECS 1800-2024<\/td>\n<td>\u300a\u597d\u623f\u5b50\u6280\u672f\u5bfc\u5219\u300b<\/td>\n<td>\u73b0\u884c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">1.5 \u201c\u4e94\u6052\u201d\u6307\u6807\u7684\u884c\u4e1a\u5171\u8bc6<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u5ea6<\/strong><\/td>\n<td><strong>\u884c\u4e1a\u4e3b\u6d41\u5b9a\u4e49<\/strong><\/td>\n<td><strong>\u672c\u624b\u518c\u91c7\u7528\u6807\u51c6<\/strong><\/td>\n<td><strong>\u597d\u623f\u5b50\u6807\u51c6<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u6052\u6e29<\/strong><\/td>\n<td>\u5168\u5e7420-26\u2103\uff0c\u6ce2\u52a8\u00b11\u2103<\/td>\n<td>\u540c\u5de6<\/td>\n<td>\u64cd\u4f5c\u6e29\u5ea6\u00b11\u2103<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6052\u6e7f<\/strong><\/td>\n<td>\u76f8\u5bf9\u6e7f\u5ea630%-70%<\/td>\n<td>40%-60%<\/td>\n<td>\u542b\u6e7f\u91cf\u63a7\u5236<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6052\u6c27<\/strong><\/td>\n<td>CO\u2082&lt;1000ppm<\/td>\n<td>\u2264800ppm<\/td>\n<td>\u2264800ppm<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6052\u6d01<\/strong><\/td>\n<td>PM2.5&lt;35\u03bcg\/m\u00b3<\/td>\n<td>\u226425\u03bcg\/m\u00b3<\/td>\n<td>PM2.5\u226425\u03bcg\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6052\u9759<\/strong><\/td>\n<td>\u226435dB(A)<\/td>\n<td>\u5367\u5ba4\u226430dB\uff0c\u5ba2\u5385\u226435dB<\/td>\n<td>\u500d\u9891\u5e26\u58f0\u538b\u7ea7\u9650\u5236<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e8c\u90e8\u5206\uff1a\u4e94\u6052\u7684\u4e94\u5927\u7ef4\u5ea6\u6df1\u5ea6\u89e3\u6790<\/h2>\n<h3 class=\"wp-block-heading\">2.1 \u6052\u6e29\u2014\u2014\u6e29\u5ea6\u6ce2\u52a8\u7684\u7cbe\u51c6\u63a7\u5236<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u539f\u7406<\/strong>\uff1a\u6052\u6e29\u7684\u6838\u5fc3\u662f\u5c06<strong>\u6e29\u5ea6\u6ce2\u52a8\u63a7\u5236\u5728\u00b11\u2103\u4ee5\u5185<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>Fanger\u6559\u6388\u4eba\u4f53\u70ed\u8212\u9002\u7406\u8bba<\/strong>\uff1aPMV\u6a21\u578b\u5305\u542b\u7a7a\u6c14\u6e29\u5ea6\u3001\u5e73\u5747\u8f90\u5c04\u6e29\u5ea6\u3001\u76f8\u5bf9\u6e7f\u5ea6\u3001\u7a7a\u6c14\u6d41\u901f\u3001\u4eba\u4f53\u4ee3\u8c22\u7387\u3001\u670d\u88c5\u70ed\u963b6\u4e2a\u8981\u7d20\u3002\u5f53PMV=0\u4e14PPD\u226410%\uff0c\u89c6\u4e3a\u7406\u60f3\u70ed\u8212\u9002\u72b6\u6001\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6280\u672f\u5b9e\u73b0<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6280\u672f\u624b\u6bb5<\/strong><\/td>\n<td><strong>\u4f5c\u7528<\/strong><\/td>\n<td><strong>\u9002\u7528\u7cfb\u7edf<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u53d8\u9891\u538b\u7f29\u673a<\/td>\n<td>\u65e0\u7ea7\u8c03\u8282\u51b7\u70ed\u91cf\u8f93\u51fa<\/td>\n<td>\u5168\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u672b\u7aef<\/td>\n<td>\u8c03\u8282\u5efa\u7b51\u5e73\u5747\u8f90\u5c04\u6e29\u5ea6<\/td>\n<td>\u8f90\u5c04\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>AI\u9884\u6d4b\u63a7\u5236<\/td>\n<td>\u63d0\u524d\u54cd\u5e94\u8d1f\u8377\u53d8\u5316<\/td>\n<td>\u5168\u7cfb\u7edf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">2.2 \u6052\u6e7f\u2014\u2014\u542b\u6e7f\u91cf\u4e0e\u9732\u70b9\u7684\u72ec\u7acb\u63a7\u5236<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u539f\u7406<\/strong>\uff1a\u6052\u6e7f\u7684\u672c\u8d28\u662f\u63a7\u5236<strong>\u7a7a\u6c14\u542b\u6e7f\u91cf<\/strong>\uff08\u7edd\u5bf9\u6e7f\u5ea6\uff09\uff0c\u800c\u975e\u76f8\u5bf9\u6e7f\u5ea6\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6280\u672f\u5b9e\u73b0<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6280\u672f\u624b\u6bb5<\/strong><\/td>\n<td><strong>\u4f5c\u7528<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u51bb\u9664\u6e7f<\/td>\n<td>\u7a7a\u6c14\u51b7\u5374\u81f3\u9732\u70b9\u4ee5\u4e0b<\/td>\n<td>\u590f\u5b63\/\u6885\u96e8\u5b63<\/td>\n<\/tr>\n<tr>\n<td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n<td>\u9664\u6e7f\u540e\u56de\u6536\u4f59\u70ed\u518d\u70ed\uff0c\u9664\u6e7f\u4e0d\u964d\u6e29<\/td>\n<td>\u8fc7\u6e21\u5b63\/\u56de\u5357\u5929<\/td>\n<\/tr>\n<tr>\n<td>\u6eb6\u6db2\u9664\u6e7f<\/td>\n<td>\u72ec\u7acb\u5904\u7406\u6f5c\u70ed<\/td>\n<td>\u9ad8\u7aef\u8f90\u5c04\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u8f6c\u8f6e\u9664\u6e7f<\/td>\n<td>\u6df1\u5ea6\u9664\u6e7f<\/td>\n<td>\u9ad8\u70ed\u9ad8\u6e7f\u6781\u7aef\u5de5\u51b5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8f90\u5c04\u4f9b\u51b7\u9632\u7ed3\u9732\u6838\u5fc3<\/strong>\uff1a\u65b0\u98ce\u9664\u6e7f\u80fd\u529b\u5fc5\u987b\u4e0e\u5f53\u5730\u6c14\u5019\u4e25\u683c\u5339\u914d\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6c14\u5019\u533a\u57df<\/strong><\/td>\n<td><strong>\u65b0\u98ce\u5904\u7406\u540e\u542b\u6e7f\u91cf\u53ca\u683c\u7ebf<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5e72\u71e5\u5730\u533a\uff08\u5170\u5dde\uff09<\/td>\n<td>\u22649g\/kg<\/td>\n<\/tr>\n<tr>\n<td>\u6f6e\u6e7f\u5730\u533a\uff08\u5317\u4eac\uff09<\/td>\n<td>\u22648.5g\/kg<\/td>\n<\/tr>\n<tr>\n<td><strong>\u9ad8\u6e7f\u5730\u533a\uff08\u4e0a\u6d77\u3001\u6210\u90fd\uff09<\/strong><\/td>\n<td><strong>\u22648.0g\/kg<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8f90\u5c04\u677f\u7ed3\u9732\u7684\u7269\u7406\u8fc7\u7a0b\uff08\u6e05\u534e\u5927\u5b66\u5b9e\u9a8c\u6570\u636e\uff09<\/strong>\uff1a<\/p>\n<ol class=\"wp-block-list\">\n<li><strong>\u8d77\u96fe<\/strong>\uff1a\u8868\u9762\u6e29\u5ea6\u4f4e\u4e8e\u9732\u70b9\uff0c\u6c34\u84b8\u6c14\u51dd\u7ed3\u6210\u5fae\u96fe<\/li>\n<li><strong>\u6210\u73e0<\/strong>\uff1a\u7ea6<strong>30\u5206\u949f<\/strong>\u540e\uff0c\u96fe\u6c14\u6c47\u805a\u6210\u9732\u73e0<\/li>\n<li><strong>\u6ef4\u843d<\/strong>\uff1a\u7ea6<strong>4\u5c0f\u65f6<\/strong>\u540e\u5f00\u59cb\u6ef4\u843d<\/li>\n<\/ol>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u542f\u793a<\/strong>\uff1a\u7ed3\u9732\u524d\u7684\u51e0\u5341\u5206\u949f\u5ef6\u8fdf\uff0c\u662f\u7559\u7ed9\u65b0\u98ce\u9664\u6e7f\u7cfb\u7edf\u8fdb\u884c<strong>\u6e7f\u5ea6\u5e72\u9884<\/strong>\u7684\u9ec4\u91d1\u7a97\u53e3\u3002<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">2.3 \u6052\u6c27\u2014\u2014CO\u2082\u6d53\u5ea6\u4e0e\u65b0\u98ce\u91cf\u7684\u5e73\u8861<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u539f\u7406<\/strong>\uff1a\u201c\u6052\u6c27\u201d\u5b9e\u9645\u63a7\u5236\u7684\u662f<strong>CO\u2082\u6d53\u5ea6<\/strong>\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u6280\u672f\u5b9e\u73b0<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6280\u672f\u624b\u6bb5<\/strong><\/td>\n<td><strong>\u4f5c\u7528<\/strong><\/td>\n<td><strong>\u8bbe\u8ba1\u53c2\u6570<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/td>\n<td>\u56de\u6536\u6392\u98ce\u80fd\u91cf<\/td>\n<td>\u70ed\u4ea4\u6362\u6548\u7387\u226570%<\/td>\n<\/tr>\n<tr>\n<td>CO\u2082\u4f20\u611f\u5668\u8054\u52a8<\/td>\n<td>\u6839\u636e\u6d53\u5ea6\u81ea\u52a8\u8c03\u8282\u65b0\u98ce\u91cf<\/td>\n<td>CO\u2082\u2264800ppm<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u5faa\u73af\u68c0\u6d4b<\/td>\n<td>\u5b9e\u65f6\u76d1\u6d4b\u7a7a\u6c14\u8d28\u91cf<\/td>\n<td>\u4e94\u7ef4\u76d1\u6d4b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u65b0\u98ce\u4e0e\u5faa\u73af\u7684\u804c\u80fd\u5206\u79bb<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u65b0\u98ce\u7cfb\u7edf<\/strong><\/td>\n<td><strong>\u4e94\u6052\u207a\u5faa\u73af\u7cfb\u7edf<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6838\u5fc3\u804c\u80fd<\/td>\n<td>\u6362\u6c14\u3001\u5bcc\u6c27<\/td>\n<td>\u6e29\u6e7f\u5747\u5300+\u6d01\u51c0+\u5fae\u98ce\u611f<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u6c14\u6b21\u6570<\/td>\n<td>0.5-1\u6b21\/h<\/td>\n<td><strong>6-11\u6b21\/h<\/strong><\/td>\n<\/tr>\n<tr>\n<td>15\u33a1\u6240\u9700\u98ce\u91cf<\/td>\n<td>20-40 m\u00b3\/h<\/td>\n<td><strong>240-500 m\u00b3\/h<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u6362\u6c14\u6b21\u6570\u6807\u51c6\u516c\u5f0f<\/strong>\uff1an = Q \/ V\uff08Q=\u901a\u98ce\u91cf\uff0cV=\u623f\u95f4\u5bb9\u79ef\uff09<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u540c\u5c42\u9ad8\u4e0b\u7684\u5faa\u73af\u98ce\u91cf<\/strong>\uff0815\u33a1\u4e3a\u4f8b\uff09\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5c42\u9ad8<\/strong><\/td>\n<td><strong>\u623f\u95f4\u4f53\u79ef<\/strong><\/td>\n<td><strong>\u6362\u6c146\u6b21\/h<\/strong><\/td>\n<td><strong>\u6362\u6c1411\u6b21\/h<\/strong><\/td>\n<\/tr>\n<tr>\n<td>2.5m<\/td>\n<td>37.5 m\u00b3<\/td>\n<td>225 m\u00b3\/h<\/td>\n<td>412.5 m\u00b3\/h<\/td>\n<\/tr>\n<tr>\n<td>2.7m<\/td>\n<td>40.5 m\u00b3<\/td>\n<td>243 m\u00b3\/h<\/td>\n<td>445.5 m\u00b3\/h<\/td>\n<\/tr>\n<tr>\n<td>3.0m<\/td>\n<td>45 m\u00b3<\/td>\n<td>270 m\u00b3\/h<\/td>\n<td>495 m\u00b3\/h<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">2.4 \u6052\u6d01\u2014\u2014\u591a\u7ea7\u8fc7\u6ee4\u4e0e\u6740\u83cc\u6280\u672f<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6280\u672f\u624b\u6bb5<\/strong><\/td>\n<td><strong>\u8fc7\u6ee4\u5bf9\u8c61<\/strong><\/td>\n<td><strong>\u6548\u7387<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u521d\u6548\u8fc7\u6ee4\uff08G4\uff09<\/td>\n<td>&gt;10\u03bcm\u9897\u7c92<\/td>\n<td>\u4fdd\u62a4\u540e\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>\u4e2d\u6548\u8fc7\u6ee4\uff08F7-F9\uff09<\/td>\n<td>1-10\u03bcm\u9897\u7c92<\/td>\n<td>\u82b1\u7c89\u3001\u90e8\u5206PM2.5<\/td>\n<\/tr>\n<tr>\n<td>HEPA\u9ad8\u6548\uff08H13-H14\uff09<\/td>\n<td>\u22640.3\u03bcm\u9897\u7c92<\/td>\n<td>PM2.5\u226599.97%<\/td>\n<\/tr>\n<tr>\n<td>PE\u51c0\u5316\u6a21\u5757<\/td>\n<td>PM2.5\/\u7532\u919b<\/td>\n<td>\u53bb\u9664\u738799%<\/td>\n<\/tr>\n<tr>\n<td>UVC\u6df1\u7d2b\u5916<\/td>\n<td>\u7ec6\u83cc\/\u75c5\u6bd2<\/td>\n<td>254nm\u6740\u83cc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">2.5 \u6052\u9759\u2014\u2014\u58f0\u6e90+\u4f20\u64ad+\u672b\u7aef\u4e09\u91cd\u964d\u566a<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9632\u7ebf<\/strong><\/td>\n<td><strong>\u6280\u672f\u63aa\u65bd<\/strong><\/td>\n<td><strong>\u6548\u679c<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u58f0\u6e90<\/td>\n<td>\u53d8\u9891\u9759\u97f3\u5916\u673a+\u76f4\u6d41\u65e0\u5237\u5185\u673a<\/td>\n<td>\u65e5\u7acb\u5185\u673a\u6700\u4f4e17dB<\/td>\n<\/tr>\n<tr>\n<td>\u4f20\u64ad<\/td>\n<td>\u6d88\u58f0\u5668+\u9694\u97f3\u68c9+\u51cf\u9707\u57ab<\/td>\n<td>\u5207\u65ad\u4f20\u64ad\u8def\u5f84<\/td>\n<\/tr>\n<tr>\n<td>\u672b\u7aef<\/td>\n<td>CFD\u6c14\u6d41\u6a21\u62df+\u4f4e\u98ce\u901f\u8bbe\u8ba1<\/td>\n<td>\u907f\u514d\u98ce\u566a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">2.6 \u98ce\u611f\u7684\u4ef7\u503c\u4e0e\u79d1\u5b66\u5f15\u8bc1<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u8ba4\u77e5<\/strong>\uff1a\u4e94\u6052\u7cfb\u7edf\u8ffd\u6c42\u7684\u4e0d\u662f\u201c\u7edd\u5bf9\u65e0\u98ce\u201d\uff0c\u800c\u662f\u201c\u65e0\u611f\u4e4b\u98ce\u201d\uff080.1-0.3m\/s\uff09\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u79d1\u5b66\u5f15\u8bc1\u4e00\uff1aMIT\u300a\u81ea\u884c\u8f66\u79d1\u5b66\u300b\u7ecf\u5178\u5b9e\u9a8c<\/strong>\u4e13\u4e1a\u8f66\u624b\u5ba4\u5185373W\u529f\u7387\u53ea\u80fd\u575a\u63015-15\u5206\u949f\uff0c\u540c\u4e00\u6279\u8f66\u624b\u6237\u5916\u80fd\u4ee5\u63a5\u8fd1\u529f\u7387\u5b8c\u62101\u5c0f\u65f6\u3002\u5dee\u5728<strong>\u98ce<\/strong>\u2014\u2014\u6d41\u52a8\u7a7a\u6c14\u5e26\u8d70\u70ed\u91cf\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u79d1\u5b66\u5f15\u8bc1\u4e8c\uff1aJSCR\u671f\u520a\u8bba\u6587<\/strong>\u6237\u5916\u6bd4\u5ba4\u5185\u529f\u7387\u9ad827%\uff0c\u76ae\u80a4\u6e29\u5ea6\u4f4e1.6\u2103\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u5b8c\u5168\u65e0\u98ce\u4f1a\u5f62\u6210\u201c\u5fae\u6c14\u5019\u5305\u56f4\u5708\u201d\uff0c\u5bfc\u81f4\u95f7\u70ed\u3001\u5934\u660f\u3002\u4e94\u6052\u7cfb\u7edf\u7684\u5fae\u98ce\u5faa\u73af\u6253\u7834\u70ed\u8fb9\u754c\u5c42\uff0c\u5b9e\u73b0\u771f\u6b63\u8212\u9002\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e09\u90e8\u5206\uff1a\u5168\u7a7a\u6c14\u7cfb\u7edf vs \u8f90\u5c04\u7cfb\u7edf vs \u590d\u5408\u5f0f\u7cfb\u7edf<\/h2>\n<h3 class=\"wp-block-heading\">3.1 \u7cfb\u7edf\u5b9a\u4e49\u4e0e\u539f\u7406<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u5168\u7a7a\u6c14\u7cfb\u7edf<\/strong>\uff1a\u901a\u8fc7AHU\u7edf\u4e00\u8c03\u63a7\u9001\u98ce\u53c2\u6570\uff0c\u4ee5\u7a7a\u6c14\u4e3a\u552f\u4e00\u4ecb\u8d28\u3002\u6362\u6c146-11\u6b21\/h\uff0c\u65b0\u98ce\u5360\u6bd420-30%\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8f90\u5c04\u7cfb\u7edf<\/strong>\uff1a\u4ee5\u8f90\u5c04\u4f20\u70ed\u4e3a\u6838\u5fc3\uff0c\u901a\u8fc7\u6bdb\u7ec6\u7ba1\u7f51\/\u8f90\u5c04\u677f\/\u5730\u6696\u8c03\u8282\u5efa\u7b51\u5185\u8868\u9762\u6e29\u5ea6\uff0c\u914d\u5907\u72ec\u7acb\u65b0\u98ce\u9664\u6e7f\u7cfb\u7edf\u3002\u6838\u5fc3\u9075\u5faa\u201c\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\uff08THIC\uff09\u201d\u7406\u8bba\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u590d\u5408\u5f0f\u7cfb\u7edf<\/strong>\uff1a\u878d\u5408\u8f90\u5c04\u672b\u7aef\u3001\u98ce\u673a\u76d8\u7ba1\u3001\u5168\u7a7a\u6c14AHU\u7b49\u591a\u79cd\u672b\u7aef\u7684\u6df7\u5408\u7cfb\u7edf\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.2 \u6838\u5fc3\u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u5168\u7a7a\u6c14\u7cfb\u7edf<\/strong><\/td>\n<td><strong>\u8f90\u5c04\u7cfb\u7edf<\/strong><\/td>\n<td><strong>\u590d\u5408\u5f0f\u7cfb\u7edf<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u63a7\u65b9\u5f0f<\/td>\n<td>\u7a7a\u6c14\u5faa\u73af<\/td>\n<td>\u8f90\u5c04\u6362\u70ed+\u65b0\u98ce\u8f85\u52a9<\/td>\n<td>\u6df7\u5408<\/td>\n<\/tr>\n<tr>\n<td>\u8212\u9002\u5ea6<\/td>\n<td>\u6e29\u5ea6\u5747\u5300<\/td>\n<td><strong>\u6781\u9ad8<\/strong>\uff08\u5782\u76f4\u6e29\u5dee\u00b11\u2103\uff09<\/td>\n<td>\u6700\u4f18<\/td>\n<\/tr>\n<tr>\n<td>\u54cd\u5e94\u901f\u5ea6<\/td>\n<td><strong>\u5feb<\/strong><\/td>\n<td>\u6162<\/td>\n<td>\u5feb<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u7ed3\u9732<\/td>\n<td>\u65e0\u98ce\u9669<\/td>\n<td><strong>\u9700\u4e25\u683c\u76d1\u63a7\u9732\u70b9<\/strong><\/td>\n<td>\u5206\u533a\u7ba1\u7406<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u573a\u666f<\/td>\n<td>\u522b\u5885\/\u5927\u5e73\u5c42<\/td>\n<td>\u6781\u81f4\u8212\u9002\u8ffd\u6c42<\/td>\n<td>\u9876\u7ea7\u8c6a\u5b85<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">3.3 \u6bdb\u7ec6\u7ba1\u7f51\u5730\u9762\u8f90\u5c04\u4f9b\u51b7\uff08\u8bba\u6587\u7cbe\u534e\uff09<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u6bdb\u7ec6\u7ba1\u7f51 vs \u4f20\u7edf\u5730\u6696\u7ba1<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u4f20\u7edf\u5730\u6696\u7ba1\uff08\u03a620\uff0c\u95f4\u8ddd200mm\uff09<\/strong><\/td>\n<td><strong>\u6bdb\u7ec6\u7ba1\u7f51\uff08\u03a63.5-4.3mm\uff0c\u95f4\u8ddd0.8-10mm\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6bcf\u5e73\u7c73\u9759\u6001\u6c34\u91cf<\/td>\n<td>\u7ea61005g<\/td>\n<td>320-491g<\/td>\n<\/tr>\n<tr>\n<td>\u84c4\u70ed\u5c42\u539a\u5ea6<\/td>\n<td>\u226550mm<\/td>\n<td>\u53ef\u8584\u81f330mm<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u60f0\u6027<\/td>\n<td>\u5927<\/td>\n<td>\u5c0f\uff08\u54cd\u5e94\u5feb\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u51b7\u80fd\u529b\uff08\u5730\u9762\uff09<\/td>\n<td>\u4e0d\u9002\u7528<\/td>\n<td><strong>\u53ef\u8fbe90W\/\u33a1<\/strong>\uff0810-22\u2103\u4f9b\u6c34\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u51b7\u80fd\u529b\uff08\u9876\u68da\uff09<\/td>\n<td>\u2014<\/td>\n<td>\u226460W\/\u33a1\uff0817-20\u2103\u4f9b\u6c34\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u5730\u9762\u4f9b\u51b7 vs \u9876\u68da\u4f9b\u51b7<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u5730\u9762\u8f90\u5c04\u4f9b\u51b7<\/strong><\/td>\n<td><strong>\u9876\u68da\u8f90\u5c04\u4f9b\u51b7<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u51b7\u80fd\u529b<\/td>\n<td>\u53ef\u8fbe90W\/\u33a1<\/td>\n<td>\u4e0d\u8d85\u8fc760W\/\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>10-22\u2103\u53ef\u8c03<\/td>\n<td>17-20\u2103\u53d7\u9650<\/td>\n<\/tr>\n<tr>\n<td>\u7ed3\u9732\u98ce\u9669<\/td>\n<td>\u4f4e<\/td>\n<td>\u9ad8<\/td>\n<\/tr>\n<tr>\n<td>\u6781\u7aef\u5929\u6c14\u5e94\u5bf9<\/td>\n<td>\u53ef\u964d\u4f4e\u4f9b\u6c34\u6e29\u5ea6<\/td>\n<td>\u5fc5\u987b\u8c03\u9ad8\u6c34\u6e29\u9632\u7ed3\u9732<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">3.4 \u8f90\u5c04\u7cfb\u7edf\u7684\u4f18\u52bf\u4e0e\u5c40\u9650<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u4f18\u52bf<\/strong>\uff1a\u8212\u9002\u6027\u5353\u8d8a\u3001\u80fd\u6548\u663e\u8457\uff08\u8f83\u4f20\u7edf\u7a7a\u8c03\u8282\u80fd15-20%\uff09\u3001\u9759\u97f3\u3001\u5065\u5eb7\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u5c40\u9650<\/strong>\uff1a\u521d\u6295\u8d44\u9ad8\uff08\u589e\u52a040-60%\uff09\u3001\u9632\u7ed3\u9732\u6311\u6218\u5927\u3001\u5bf9\u56f4\u62a4\u7ed3\u6784\u4fdd\u6e29\u6709\u8981\u6c42\u3002<\/p>\n<h3 class=\"wp-block-heading\">3.5 DOAS\u5168\u7a7a\u6c14\u7cfb\u7edf<\/h3>\n<p class=\"wp-block-paragraph\">DOAS\u5185\u7f6e\u72ec\u7acb\u65b0\u98ce\u5904\u7406\u6bb5\uff0c\u5148\u628a\u5ba4\u5916\u7a7a\u6c14\u5904\u7406\u6210\u7406\u60f3\u72b6\u6001\u518d\u4e0e\u56de\u98ce\u6df7\u5408\uff0c\u5b9e\u73b0\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\u3002\u9700\u4e24\u7ea7\u751a\u81f3\u4e09\u7ea7\u5904\u7406\uff0c\u5bf9\u8bbe\u5907\u5382\u5bb6\u63d0\u51fa\u66f4\u9ad8\u8981\u6c42\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u56db\u90e8\u5206\uff1a\u6838\u5fc3\u5b50\u7cfb\u7edf\u6df1\u5ea6\u89e3\u6790<\/h2>\n<h3 class=\"wp-block-heading\">4.1 \u5168\u7a7a\u6c14\u7cfb\u7edf\uff08AHU\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ec4\u4ef6<\/strong><\/td>\n<td><strong>\u529f\u80fd<\/strong><\/td>\n<td><strong>\u6280\u672f\u8981\u6c42<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u53d8\u9891\u70ed\u6cf5\u4e3b\u673a<\/td>\n<td>\u5236\u51b7\/\u5236\u70ed<\/td>\n<td>\u5168\u53d8\u9891\uff0c\u4f4e\u6e29\u5236\u70ed\u80fd\u529b\u5f3a<\/td>\n<\/tr>\n<tr>\n<td>AHU\u7a7a\u6c14\u5904\u7406\u673a\u7ec4<\/td>\n<td>\u8fc7\u6ee4+\u6362\u70ed+\u9001\u98ce<\/td>\n<td>\u65b0\u98ce\/\u56de\u98ce\/\u9001\u98ce\u72ec\u7acb\u98ce\u9053<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u7ba1\u7cfb\u7edf<\/td>\n<td>\u7a7a\u6c14\u8f93\u914d<\/td>\n<td>\u591a\u5206\u652f\u7ba1\u9053\uff0cBIM\u8bbe\u8ba1<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u7cfb\u7edf<\/td>\n<td>\u81ea\u52a8\u5316\u8fd0\u884c<\/td>\n<td>AI-LiNK\/\u7269\u8054\u7f51\u5e73\u53f0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">4.2 \u8f90\u5c04\u7cfb\u7edf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5f62\u5f0f<\/strong><\/td>\n<td><strong>\u7279\u70b9<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6bdb\u7ec6\u7ba1\u7f51<\/td>\n<td>\u6362\u70ed\u9762\u79ef\u5927\uff0c\u5747\u5300\u6027\u597d<\/td>\n<td>\u9876\u9762\/\u5899\u9762\u9884\u57cb<\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u677f<\/td>\n<td>\u5de5\u5382\u9884\u5236\uff0c\u5b89\u88c5\u4fbf\u6377<\/td>\n<td>\u9876\u9762\u94fa\u8bbe<\/td>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u76d8\u7ba1<\/td>\n<td>\u6280\u672f\u6210\u719f\uff0c\u6210\u672c\u4f4e<\/td>\n<td>\u5730\u9762\u8f90\u5c04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u8ffd\u9732\u70b9\u53d8\u6c34\u6e29\u6280\u672f<\/strong>\uff1a\u5b9e\u65f6\u76d1\u6d4b\u9732\u70b9\u6e29\u5ea6\uff0c\u52a8\u6001\u8c03\u8282\u4f9b\u6c34\u6e29\u5ea6\uff0c\u786e\u4fdd\u8f90\u5c04\u8868\u9762\u59cb\u7ec8\u9ad8\u4e8e\u9732\u70b9\u3002<\/p>\n<h3 class=\"wp-block-heading\">4.3 \u65b0\u98ce\u9664\u6e7f\u7cfb\u7edf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u5236\u51b7\u9664\u6e7f<\/strong><\/td>\n<td><strong>\u72ec\u7acb\u9664\u6e7f\uff08\u4e09\u7ba1\u5236\uff09<\/strong><\/td>\n<td><strong>\u9664\u6e7f\u65b0\u98ce<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u539f\u7406<\/td>\n<td>\u5236\u51b7\u65f6\u7a7a\u6c14\u8fc7\u51b7\u51dd\u6c34<\/td>\n<td>\u4e09\u7ba1\u5236\u72ec\u7acb\u9664\u6e7f<\/td>\n<td>\u538b\u7f29\u673a\u5236\u51b7\u9664\u6e7f+\u65b0\u98ce<\/td>\n<\/tr>\n<tr>\n<td>\u662f\u5426\u964d\u6e29<\/td>\n<td>\u2705 \u662f<\/td>\n<td>\u274c \u5426<\/td>\n<td>\u274c \u5426<\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u9002\u7528<\/td>\n<td>\u8f85\u52a9<\/td>\n<td>\u2705 \u9996\u9009<\/td>\n<td>\u2705 \u9996\u9009<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u5929\u6c1f\u5730\u6c34\/\u5929\u6c34\u5730\u6c34\u7684\u9664\u6e7f\u8fb9\u754c<\/strong>\uff1a\u9ad8\u8d1f\u8377\u8fd0\u884c\u65f6\u9664\u6e7f\u80fd\u529b\u53d7\u9650\uff0c\u9700\u9664\u6e7f\u65b0\u98ce\u72ec\u7acb\u9664\u6e7f\u3002<\/p>\n<h3 class=\"wp-block-heading\">4.4 \u52a0\u6e7f\u7cfb\u7edf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td>\n<td><strong>\u7b49\u6e29\u52a0\u6e7f\uff08\u84b8\u6c7d\uff09<\/strong><\/td>\n<td><strong>\u7b49\u7113\u52a0\u6e7f\uff08\u6e7f\u819c\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u539f\u7406<\/td>\n<td>\u7535\u52a0\u70ed\u6c34\u4ea7\u751f\u84b8\u6c7d<\/td>\n<td>\u6c34\u84b8\u53d1\u5438\u6536\u70ed\u91cf<\/td>\n<\/tr>\n<tr>\n<td>\u80fd\u8017<\/td>\n<td>\u8f83\u9ad8<\/td>\n<td>\u4f4e<\/td>\n<\/tr>\n<tr>\n<td>\u536b\u751f\u98ce\u9669<\/td>\n<td>\u4f4e\uff08\u9ad8\u6e29\u6740\u83cc\uff09<\/td>\n<td>\u9ad8<\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u9002\u7528<\/td>\n<td>\u2705 \u63a8\u8350<\/td>\n<td>\u26a0\ufe0f \u9700\u5b9a\u671f\u7ef4\u62a4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">4.5 \u5206\u533a\u63a7\u5236\u7cfb\u7edf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4ef7\u503c<\/strong><\/td>\n<td><strong>\u8bf4\u660e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e2a\u6027\u5316\u8212\u9002<\/td>\n<td>\u4e0d\u540c\u5e74\u9f84\u3001\u4e0d\u540c\u4f53\u611f\u5404\u5f97\u5176\u6240<\/td>\n<\/tr>\n<tr>\n<td>\u8282\u80fd\u964d\u8017<\/td>\n<td>\u65e0\u4eba\u533a\u57df\u81ea\u52a8\u8282\u80fd<\/td>\n<\/tr>\n<tr>\n<td>\u573a\u666f\u8054\u52a8<\/td>\n<td>\u79bb\u5bb6\/\u56de\u5bb6\/\u7761\u7720\/\u805a\u4f1a\u4e00\u952e\u5207\u6362<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">4.6 \u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\u6280\u672f\uff08THIC\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\u6c5f\u4ebf\u9662\u58eb\u63d0\u51fa\uff1a\u663e\u70ed\u4e0e\u6f5c\u70ed\u5206\u79bb\u5904\u7406\u3002\u663e\u70ed\u8d1f\u8377\u7531\u5e72\u5de5\u51b5\u672b\u7aef\u627f\u62c5\uff0c\u6f5c\u70ed\u8d1f\u8377\u7531\u4f4e\u6e7f\u5ea6\u7a7a\u6c14\u627f\u62c5\u3002\u7406\u8bba\u8282\u80fd\u7387\u8fbe30%-50%\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e94\u90e8\u5206\uff1a\u65e5\u7acb\u5168\u5c4b\u5168\u611f3.0\u7cfb\u7edf<\/h2>\n<h3 class=\"wp-block-heading\">5.1 \u7cfb\u7edf\u5b9a\u4f4d\u4e0e\u6f14\u8fdb<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7248\u672c<\/strong><\/td>\n<td><strong>\u53d1\u5e03\u65f6\u95f4<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u7279\u70b9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5168\u5c4b\u5168\u611f1.0<\/td>\n<td>2022\u5e74<\/td>\n<td>\u516b\u7ef4\u5168\u611f\uff0c\u667a\u6167\u7a7a\u6c14\u5b9a\u5236<\/td>\n<\/tr>\n<tr>\n<td>\u5168\u5c4b\u5168\u611f2.0<\/td>\n<td>2023-2024\u5e74<\/td>\n<td>\u667a\u6167\u96c6\u63a7\u5c4f+\u84dd\u8272\u5c0f\u7403\u6fc0\u6d3b<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5168\u5c4b\u5168\u611f3.0<\/strong><\/td>\n<td><strong>2025-2026\u5e74<\/strong><\/td>\n<td>AI\u667a\u6167\u8d85\u8111+500\u4e07+\u7a7a\u6c14\u6837\u672c+\u5206\u57df\u5206\u65f6+\u6700\u9ad816\u53f0\u5e76\u8054<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">5.2 \u7cfb\u7edf\u67b6\u6784<\/h3>\n<pre class=\"wp-block-code\"><code>\u250c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2510\n\u2502                    AI\u667a\u6167\u8d85\u8111\uff08DeepSeek\u5f15\u64ce\uff09            \u2502\n\u2502                  500\u4e07+\u771f\u5b9e\u7a7a\u6c14\u6837\u672c\u6570\u636e\u5e93                 \u2502\n\u2502               \u81ea\u5b66\u4e60\u00b7\u81ea\u611f\u77e5\u00b7\u81ea\u5224\u65ad\u00b7\u81ea\u8c03\u8282                 \u2502\n\u2514\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2518\n         \u2193              \u2193              \u2193              \u2193\n\u250c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2510 \u250c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2510 \u250c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2510 \u250c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2510\n\u2502  \u7a7a\u8c03+\u5730\u6696   \u2502 \u2502  \u9664\u6e7f\u65b0\u98ce   \u2502 \u2502  \u52a0\u6e7f\u6a21\u5757   \u2502 \u2502  \u51c0\u5316\u5185\u673a   \u2502\n\u2502 (\u5c0a\u777f\u5168\u6548\u2161) \u2502 \u2502  (\u5929\u51c0Q7)   \u2502 \u2502  (OPT-JS)   \u2502 \u2502 (PE\u6a21\u5757)    \u2502\n\u2514\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2518 \u2514\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2518 \u2514\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2518 \u2514\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2518\n<\/code><\/pre>\n<h3 class=\"wp-block-heading\">5.3 \u6838\u5fc3\u529f\u80fd<\/h3>\n<p class=\"wp-block-paragraph\"><strong>1. AI\u667a\u6167\u8d85\u8111<\/strong>\uff1a500\u4e07+\u7a7a\u6c14\u6837\u672c+DeepSeek\u5f15\u64ce\uff0c\u81ea\u5b66\u4e60\u3001\u81ea\u611f\u77e5\u3001\u81ea\u5224\u65ad\u3001\u81ea\u8c03\u8282\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>2. \u5206\u57df\u5206\u65f6\u5168\u5c4b\u5168\u611f<\/strong>\uff1a\u5404\u623f\u95f4\u72ec\u7acb\u53c2\u6570\u8bbe\u7f6e\uff0c\u6e7f\u5ea656\u6863\u7cbe\u51c6\u8c03\u8282\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>3. \u667a\u80fd\u6a21\u5f0f vs \u5f3a\u5236\u6a21\u5f0f<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u6a21\u5f0f<\/strong><\/td>\n<td><strong>\u51fa\u98ce\u53e3\u6e29\u5ea6<\/strong><\/td>\n<td><strong>\u4f53\u611f<\/strong><\/td>\n<td><strong>\u8fd0\u884c\u903b\u8f91<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5168\u5c4b\u5168\u611f\u667a\u80fd\u6a21\u5f0f<\/td>\n<td>\u7ea624\u2103<\/td>\n<td>\u51c9\u800c\u4e0d\u51b7\uff0c\u65e0\u98ce\u611f<\/td>\n<td>\u81ea\u52a8\u53d8\u6c34\u6e29\/\u53d8\u6c1f\u6e29<\/td>\n<\/tr>\n<tr>\n<td>\u5f3a\u5236\u5236\u51b7\u6a21\u5f0f<\/td>\n<td>\u7ea610\u2103<\/td>\n<td>\u51b7\u98ce\u76f4\u5439<\/td>\n<td>\u5e38\u89c4\u5b9a\u6e29\u5236\u51b7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">5.4 \u4ea7\u54c1\u914d\u7f6e\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7cfb\u7edf\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u6838\u5fc3\u8bbe\u5907<\/strong><\/td>\n<td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u6c1f\u5730\u6c34\u4e94\u6052<\/strong><\/td>\n<td>\u5c0a\u777f\u5168\u6548\u2161+\u5929\u51c0\u9664\u6e7f\u65b0\u98ce+PE\u51c0\u5316+\u96c6\u63a7\u5c4f<\/td>\n<td>\u5e38\u89c4\u4f4f\u5b85<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5929\u6c34\u5730\u6c34\u4e94\u6052<\/strong><\/td>\n<td>\u6c34\u5885\u9002+\u5929\u51c0\u9664\u6e7f\u65b0\u98ce+PE\u51c0\u5316+\u96c6\u63a7\u5c4f<\/td>\n<td>\u522b\u5885\u5927\u5b85<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e09\u8054\u4f9b\u4e94\u6052<\/strong><\/td>\n<td>\u5c0a\u777f\u5168\u6548\u2161\u4e09\u8054\u4f9b+\u9664\u6e7f\u65b0\u98ce+\u96c6\u63a7\u5c4f<\/td>\n<td>\u9700\u751f\u6d3b\u70ed\u6c34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u516d\u90e8\u5206\uff1a\u8bbe\u8ba1\u89c4\u8303\u4e0e\u65bd\u5de5\u9a8c\u6536<\/h2>\n<h3 class=\"wp-block-heading\">6.1 \u8bbe\u8ba1\u6d41\u7a0b<\/h3>\n<pre class=\"wp-block-code\"><code>\u672b\u7aef\u9700\u6c42\u5206\u6790 \u2192 \u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97 \u2192 \u98ce\u7cfb\u7edf\u8bbe\u8ba1 \u2192 \u6c34\u7cfb\u7edf\u8bbe\u8ba1 \u2192 \u70ed\u6e90\u9009\u578b \u2192 \u63a7\u5236\u7cfb\u7edf\u96c6\u6210 \u2192 CFD\u6a21\u62df\u9a8c\u8bc1\n<\/code><\/pre>\n<h3 class=\"wp-block-heading\">6.2 \u6838\u5fc3\u8bbe\u8ba1\u53c2\u6570\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u53c2\u6570<\/strong><\/td>\n<td><strong>\u63a8\u8350\u503c<\/strong><\/td>\n<td><strong>\u4f9d\u636e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u5185\u6e29\u5ea6\uff08\u590f\u5b63\uff09<\/td>\n<td>24-26\u2103<\/td>\n<td>GB 50736-2012<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u5185\u6e29\u5ea6\uff08\u51ac\u5b63\uff09<\/td>\n<td>20-22\u2103<\/td>\n<td>GB 50736-2012<\/td>\n<\/tr>\n<tr>\n<td>\u76f8\u5bf9\u6e7f\u5ea6<\/td>\n<td>40%-60%<\/td>\n<td>GB\/T 18883<\/td>\n<\/tr>\n<tr>\n<td>CO\u2082\u6d53\u5ea6<\/td>\n<td>\u2264800ppm<\/td>\n<td>\u5065\u5eb7\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>PM2.5<\/td>\n<td>\u226425\u03bcg\/m\u00b3<\/td>\n<td>T\/CECS 1800<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u6c14\u6b21\u6570\uff08\u4e94\u6052\uff09<\/td>\n<td>6-11\u6b21\/h<\/td>\n<td>\u9ad8\u7aef\u4f4f\u5b85\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u5185\u566a\u97f3\uff08\u5367\u5ba4\uff09<\/td>\n<td>\u226430dB<\/td>\n<td>GB 50118<\/td>\n<\/tr>\n<tr>\n<td>\u65e5\u7acb\u5185\u673a\u6700\u4f4e\u566a\u97f3<\/td>\n<td>17dB<\/td>\n<td>\u5b98\u65b9\u6570\u636e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">6.3 \u65b0\u98ce\u7cfb\u7edf\u8bbe\u8ba1\u8be6\u7ec6\u89c4\u8303<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u65b0\u98ce\u91cf\u8ba1\u7b97<\/strong>\uff1a\u4eba\u5747\u65b0\u98ce\u91cf\u6cd5 Q=n\u00d730m\u00b3\/h\uff1b\u6362\u6c14\u6b21\u6570\u6cd5 Q=V\u00d7\u6362\u6c14\u6b21\u6570\u3002\u53d6\u4e24\u8005\u8f83\u5927\u503c\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u70ed\u56de\u6536\u4e0e\u9632\u7ed3\u9732<\/strong>\uff1a\u4e25\u5bd2\/\u5bd2\u51b7\u5730\u533a\u5b9c\u7528\u663e\u70ed\uff1b\u590f\u70ed\u51ac\u51b7\u5b9c\u7528\u5168\u70ed\uff1b\u4e25\u5bd2\u5730\u533a\u9700\u9632\u7ed3\u971c\u6821\u6838\u3002<\/p>\n<h3 class=\"wp-block-heading\">6.4 \u65bd\u5de5\u9a8c\u6536\u8981\u70b9<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u9636\u6bb5<\/strong><\/td>\n<td><strong>\u9a8c\u6536\u5185\u5bb9<\/strong><\/td>\n<td><strong>\u6807\u51c6<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u9690\u853d\u5de5\u7a0b<\/td>\n<td>\u98ce\u7ba1\u6c14\u5bc6\u6027\u3001\u6c34\u7cfb\u7edf\u6253\u538b<\/td>\n<td>\u4fdd\u538b24h\u65e0\u4e0b\u964d<\/td>\n<\/tr>\n<tr>\n<td>\u8c03\u8bd5\u9636\u6bb5<\/td>\n<td>\u8bbe\u5907\u5355\u673a\u8bd5\u8fd0\u8f6c\u3001\u8054\u5408\u8c03\u8bd5<\/td>\n<td>\u603b\u98ce\u91cf\u504f\u5dee-5%~+10%<\/td>\n<\/tr>\n<tr>\n<td>\u6548\u679c\u68c0\u9a8c<\/td>\n<td>\u6e29\u6e7f\u5ea6\/CO\u2082\/PM2.5\/\u566a\u97f3<\/td>\n<td>\u8fde\u7eed\u76d1\u6d4b30\u5929\u8fbe\u6807<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e03\u90e8\u5206\uff1a\u5b9e\u6218\u6848\u4f8b\u6df1\u5ea6\u89e3\u6790<\/h2>\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u6848\u4f8b1\uff1a\u5929\u5e9c\u516c\u998616-5\u4e94\u6052\u7cfb\u7edf\u9a8c\u6536<\/a><\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a\u6210\u90fd\u00b7\u5929\u5e9c\u516c\u9986\uff0c\u4e24\u5957\u4e94\u6052\u7cfb\u7edf\u5e76\u884c<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7cfb\u7edf\u4e00<\/strong>\uff1a\u6c34\u5885\u9002+\u5929\u51c0\u9664\u6e7f\u65b0\u98ce+PE\u51c0\u5316+\u667a\u63a7\u5c4f<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u7cfb\u7edf\u4e8c<\/strong>\uff1a\u667a\u4eab\u5929\u6c1f\u5730\u6c34+\u5929\u51c0\u9664\u6e7f\u65b0\u98ce+\u51c0\u5316\u5185\u673a+\u667a\u6167\u96c6\u63a7\u5c4f<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u9a8c\u6536\u5b9e\u5f55<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u8bbe\u5907\u5168\u8fde\u63a5\u540e\u96c6\u63a7\u5c4f\u51fa\u73b0\u84dd\u8272\u5c0f\u7403\uff0c\u70b9\u51fb\u6fc0\u6d3b\u5168\u5c4b\u5168\u611f<\/li>\n<li>\u667a\u80fd\u6a21\u5f0f\u51fa\u98ce\u7ea624\u2103\uff0c\u5f3a\u5236\u6a21\u5f0f\u7ea610\u2103<\/li>\n<li>\u5185\u673a\u6700\u4f4e17dB\uff0c\u6ee1\u8db3\u9759\u97f3\u6761\u4ef6<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b2\uff1a\u82cf\u5dde\u56fd\u5bbe\u4e00\u53f7\u72ec\u680b\u522b\u5885<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a1100\u33a1\uff0c\u5730\u6e90\u70ed\u6cf5+VAV\u5168\u7a7a\u6c14+\u5730\u9762\u8f90\u5c04+\u98ce\u673a\u76d8\u7ba1<\/p>\n<p class=\"wp-block-paragraph\">\u51b7\u70ed\u6e9083kW\uff0c\u672b\u7aef\u5367\u5ba4\u5168\u7a7a\u6c14+\u8f90\u5c04\uff0c\u5ba2\u9910\u5385\u5168\u7a7a\u6c14+\u8f90\u5c04+\u88ab\u52a8\u6392\u98ce\u3002\u6362\u6c146-8\u6b21\/h\uff0c\u65b0\u98ce\u5360\u6bd420%\u3002\u6210\u679c\uff1a\u65e0\u98ce\u611f+\u5feb\u901f\u54cd\u5e94+\u5168\u7cfb\u7edf\u81ea\u52a8\u5316\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b3\uff1a\u4e2d\u5929\u897f\u592a\u6e56\u522b\u5885\u4e94\u6052<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a5000\u33a1\uff0cEcoer\u5168\u7a7a\u6c14+\u80fd\u6e90\u4e2d\u5fc3\u70ed\u6c34+\u65b0\u98ce\u70ed\u56de\u6536<\/p>\n<p class=\"wp-block-paragraph\">\u5faa\u73af\u6362\u6c146-11\u6b21\/h\uff0c\u6052\u6e2920-26\u2103\u6e29\u5dee\u00b11\u2103\uff0c\u6052\u6e7f30%-60%\u3002\u7efc\u5408\u8282\u80fd\u738735%-50%\uff0c\u8d8520\u6b21\u65b9\u6848\u4f18\u5316\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b4\uff1a\u91d1\u9e21\u6e565000\u33a1\u5927\u5b85<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a\u82cf\u5dde\u91d1\u9e21\u6e56\uff0c4\u53f0AHU\uff0815000m\u00b3\/h\u603b\u98ce\u91cf\uff09\uff0c\u5730\u6e90\u70ed\u6cf5+\u98ce\u51b7\u70ed\u6cf5\u53cc\u70ed\u6e90\u3002\u6210\u679c\uff1a\u5168\u7cfb\u7edf\u81ea\u52a8\u5316\u8fd0\u884c\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b5\uff1a\u6d77\u5c9b\u7eff\u8272\u4f4e\u78b3\u597d\u623f\u5b50<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a\u6e29\u5dde\u6d1e\u5934190\u33a1\u522b\u5885\u6539\u9020\u3002\u5899\u4f53\u5185\u4fdd\u6e29\uff08\u8fd1\u96f6\u80fd\u8017\uff09\uff0c\u5149\u4f0f\u65e5\u5747\u53d1\u753524kWh\u3002\u66fc\u745e\u5fb7\u4e94\u6052\u7cfb\u7edf\uff0c\u7efc\u5408\u8282\u80fd\u7387\u8d8585%\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b6\uff1a\u5317\u4eac\u897f\u9493\u9c7c\u53f0\u5609\u56ed<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a330\u33a1\uff0c\u8f90\u5c04\u7a7a\u8c03+\u5730\u6696\u3002\u590f\u5b6324-26\u2103\u6e7f\u5ea650-60%\uff0c\u51ac\u5b6322-24\u2103\u6e7f\u5ea640-45%\uff0c\u65b0\u98ce\u6362\u6c142\u6b21\/h\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b7\uff1a\u5b81\u6ce2\u4e5d\u6e56\u8f69\u72ec\u680b<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee<\/strong>\uff1a1300\u33a1\uff0c\u5168\u7a7a\u6c14+\u5730\u6696+\u591a\u80fd\u4e92\u8865\u30028\u53f03500\u98ce\u91cfAHU\uff0c\u6362\u6c148-9\u6b21\/h\u3002\u4ea4\u4ed8\u540e\u5730\u6696\u505c\u7528\uff0c\u51b7\u6696\u5b63\u6708\u5747\u80fd\u8017\u7ea65000\u5143\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b8\uff1a\u60a6\u84c9\u4e1c\u65b94-1\uff08\u9884\u7559\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\ud83d\udccc \u9879\u76ee\u4ea4\u4ed8\u540e\u8865\u5145\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b9\u3001 \u5929\u5e9c\u65b0\u533a\u9e93\u6e56\u6c84\u5cb8 157\u33a1\u4e94\u6052\u5168\u5c4b\u5168\u611f\uff08\u5929\u6c34\u5730\u6c34\u6574\u5957\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\u6848\u4f8b\u8be6\u60c5\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=5809\">\u9e93\u6e56\u6c84\u5cb8 157\u33a1 \u4e94\u6052\u5168\u5c4b\u5168\u611f \u00b7 \u6848\u4f8b\u8be6\u60c5<\/a><\/p>\n<ul class=\"wp-block-list\">\n<li>\u6237\u578b\uff1a157.6\u33a1\u5927\u5e73\u5c42\uff0c\u56db\u5ba4\u4e24\u5385\uff0c\u5bb6\u4e2d\u4e24\u540d\u8fc7\u654f\u513f\u7ae5<\/li>\n<li>\u5168\u5957\u4e94\u6052\u914d\u7f6e\uff1a\u65e5\u7acb\u6c34\u5885\u9002 RAS-200 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u4e3b\u673a + \u4f1f\u661f dn32 \u5730\u6696\u4e3b\u7ba1\u3001\u65e5\u7acb\u5929\u51c0 KPI-3521Q7\/FH \u9664\u6e7f\u65b0\u98ce\u3001\u6021\u53e3\u5168\u5c4b\u51c0\u6c34\u56db\u4ef6\u5957\u3001\u6797\u5185 24L \u96f6\u51b7\u6c34\u70ed\u6c34\u5668\u3001\u65e5\u7acb 32 \u5bf8 AI \u667a\u6167\u96c6\u63a7\u5c4f<\/li>\n<li>\u4e94\u6052\u5efa\u6210\u4eae\u70b9\uff1a\n<ol class=\"wp-block-list\">\n<li>\u9488\u5bf9\u6210\u90fd\u9ad8\u6e7f\u6c14\u5019\u505a\u72ec\u7acb\u9664\u6e7f\u6a21\u5757\uff0c\u5168\u5e74\u6e7f\u5ea6\u7a33\u5b9a 40%-60%\uff0c\u89e3\u51b3\u6885\u96e8\u5b63\u5899\u9762\u8fd4\u6f6e\uff1b<\/li>\n<li>\u6c34\u7cfb\u7edf\u65e0\u98ce\u76f4\u5439\uff0c\u89c4\u907f\u513f\u7ae5\u547c\u5438\u9053\u523a\u6fc0\uff0cCO\u2082\u5e38\u5e74\u2264800ppm\uff1b<\/li>\n<li>\u5b8c\u6574 10 \u56de\u8def\u5730\u6696\u5206\u533a\u63a7\u5236\uff0c\u9876\u5c42\u8d1f\u8377\u4e13\u9879\u4fee\u6b63\uff0c\u51ac\u5b63\u5168\u5c4b\u6e29\u5dee \u00b11\u2103\uff1b<\/li>\n<li>\u6574\u5957\u7cfb\u7edf AI \u8054\u52a8\uff0c\u79bb\u5bb6\u81ea\u52a8\u8282\u80fd\u3001\u56de\u5bb6\u63d0\u524d\u9884\u8c03\u6e29\u6e7f\uff1b<\/li>\n<\/ol>\n<\/li>\n<li>\u9002\u914d\u624b\u518c\u77e5\u8bc6\u70b9\uff1a\u5929\u6c34\u5730\u6c34\u590d\u5408\u5f0f\u4e94\u6052\u3001\u4e09\u7ba1\u5236\u6e29\u6e7f\u5e73\u8861\u3001\u6210\u90fd\u672c\u5730\u9ad8\u6e7f\u9632\u7ed3\u9732\u8bbe\u8ba1\u3001\u513f\u7ae5\u5065\u5eb7\u4e13\u5c5e\u4e94\u6052\u65b9\u6848<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b 10\u3001 \u5929\u5e9c\u516c\u9986 292\u33a1\u522b\u5885\u6c34\u6c1f\u590d\u5408\u4e94\u6052\u7cfb\u7edf<\/h3>\n<p class=\"wp-block-paragraph\">\u6848\u4f8b\u8be6\u60c5\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u5929\u5e9c\u516c\u9986 292\u33a1 \u522b\u5885\u6c34\u6c1f\u590d\u5408\u4e94\u6052 \u00b7 \u6848\u4f8b\u8be6\u60c5<\/a><\/p>\n<ul class=\"wp-block-list\">\n<li>\u6237\u578b\uff1a\u53cc\u5c42\u72ec\u680b\u522b\u5885\uff0c292\u33a1\u6539\u5584\u5927\u5b85<\/li>\n<li>\u5168\u5957\u4e94\u6052\u914d\u7f6e\uff1a\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u6c1f\u673a\uff08\u5ba2\u9910\u5385\uff09+ \u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff08\u5367\u5ba4\u9759\u533a\uff09\u3001\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u3001\u5168\u5c4b\u51c0\u6c34\u3001\u5206\u533a\u667a\u6167\u96c6\u63a7<\/li>\n<li>\u4e94\u6052\u5efa\u6210\u4eae\u70b9\uff1a\n<ol class=\"wp-block-list\">\n<li>\u590d\u5408\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u516c\u5171\u533a\u57df\u5feb\u901f\u8c03\u6e29\u3001\u5367\u5ba4\u8f90\u5c04\u65e0\u98ce\u9759\u97f3\uff1b<\/li>\n<li>\u4e24\u5957\u51b7\u70ed\u6e90\u4e92\u4e3a\u5907\u7528\uff0c\u675c\u7edd\u5355\u4e00\u4e3b\u673a\u6545\u969c\u5168\u5c4b\u5931\u8861\uff1b<\/li>\n<li>\u5168\u5c4b\u4e94\u7ef4\u76d1\u6d4b\u5c4f\u5b9e\u65f6\u663e\u793a\u6e29\u6e7f \/ PM2.5\/CO\u2082\/ \u566a\u97f3\uff0c\u5367\u5ba4\u591c\u95f4\u4f4e\u81f3 30dB\uff1b<\/li>\n<li>\u9002\u914d\u522b\u5885\u5206\u5c42\u51b7\u70ed\u8d1f\u8377\u5dee\u5f02\uff0c\u5206\u5c42\u72ec\u7acb\u6c34\u529b\u5e73\u8861\uff1b<\/li>\n<\/ol>\n<\/li>\n<li>\u9002\u914d\u624b\u518c\u77e5\u8bc6\u70b9\uff1a\u590d\u5408\u5f0f\u4e94\u6052\u7cfb\u7edf\u3001\u591a\u70ed\u6e90\u5e76\u8054\u3001\u5206\u5c42\u5206\u533a\u667a\u80fd\u63a7\u5236\u3001\u5168\u5c4b\u5168\u611f 3.0 \u96c6\u63a7<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b 11\u3001\u851a\u84dd\u5361\u5730\u4e9a 145\u33a1\u5b55\u5988\u5988\u4e13\u5c5e\u4e94\u6052\u7cfb\u7edf<\/h3>\n<p class=\"wp-block-paragraph\">\u6848\u4f8b\u8be6\u60c5\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=2665\">\u851a\u84dd\u5361\u5730\u4e9a 145\u33a1 \u5b55\u5988\u5988\u4e13\u5c5e\u4e94\u6052 \u00b7 \u6848\u4f8b\u8be6\u60c5<\/a><\/p>\n<ul class=\"wp-block-list\">\n<li>\u6237\u578b\uff1a145\u33a1\u6539\u5584\u5e73\u5c42\uff0c\u5b55\u671f + \u5a74\u5e7c\u513f\u5bb6\u5ead<\/li>\n<li>\u5168\u5957\u4e94\u6052\u914d\u7f6e\uff1a\u65e5\u7acb\u5c0a\u777f\u5929\u6c1f\u5730\u6c34 + \u5929\u51c0 H11 \u51c0\u5316\u9664\u6e7f\u65b0\u98ce\u3001\u72ec\u7acb\u6052\u6e29\u70ed\u6c34\u3001\u5168\u5c4b\u8f6f\u6c34\u3001PE \u5ba4\u5185\u51c0\u5316\u6a21\u5757<\/li>\n<li>\u4e94\u6052\u5efa\u6210\u4eae\u70b9\uff1a\n<ol class=\"wp-block-list\">\n<li>\u65e0\u71c3\u6c14\u70ed\u6e90\u5168\u5c4b\u7535\u6c14\u5316\u4e94\u6052\uff0c\u675c\u7edd\u71c3\u6c14\u6cc4\u6f0f\u98ce\u9669\uff1b<\/li>\n<li>\u65b0\u98ce\u591a\u91cd\u8fc7\u6ee4\uff0cPM2.5 \u7a33\u5b9a\u226425\u03bcg\/m\u00b3\uff0c\u9002\u914d\u6bcd\u5a74\u654f\u611f\u4f53\u8d28\uff1b<\/li>\n<li>\u56db\u5b63\u6052\u6e29\u6052\u6e7f\uff0c\u907f\u514d\u5b55\u671f\u5e72\u71e5\u3001\u95f7\u70ed\u4e0d\u9002\uff1b<\/li>\n<li>\u91c7\u6696\u5b63\u6708\u80fd\u8017 700-900 \u5143\uff0c\u5bf9\u6bd4\u9505\u7089\u65b9\u6848\u5e74\u7701\u6570\u5343\uff1b<\/li>\n<\/ol>\n<\/li>\n<li>\u9002\u914d\u624b\u518c\u77e5\u8bc6\u70b9\uff1a\u5929\u6c1f\u5730\u6c34\u4e94\u6052\u3001\u72ec\u7acb\u9664\u6e7f\u3001\u4f4e\u566a\u65e0\u98ce\u672b\u7aef\u3001\u6bcd\u5a74\u53cb\u597d\u4eba\u5c45\u53c2\u6570<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b 12\u3001 \u548c\u8d35\u5357\u5c71\u4e0a 600\u33a1\u72ec\u680b\u522b\u5885\u4e94\u6052\u96c6\u6210\u7cfb\u7edf<\/h3>\n<p class=\"wp-block-paragraph\">\u6848\u4f8b\u8be6\u60c5\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=448\">\u548c\u8d35\u5357\u5c71\u4e0a 600\u33a1 \u72ec\u680b\u522b\u5885\u4e94\u6052 \u00b7 \u6848\u4f8b\u8be6\u60c5<\/a><\/p>\n<ul class=\"wp-block-list\">\n<li>\u6237\u578b\uff1a600\u33a1\u56db\u5c42\u72ec\u680b\uff0c\u591a\u4ee3\u540c\u5802\u5927\u5b85<\/li>\n<li>\u5168\u5957\u4e94\u6052\u914d\u7f6e\uff1a\u65e5\u7acb\u522b\u5885\u578b\u591a\u8054\u673a\u914d\u4e24\u7ba1\u5236\u6c34\u6a21\u5757\uff08RWMG-160\/200\/280\/335FWNZ1Q\uff09\u5e26\u8f90\u5c04\u5730\u6696\u76d8\u7ba1\u3001\u4e91\u51c0\u5faa\u73af\u65b0\u98ce\u3001\u5168\u5c4b\u51c0\u6c34\u52a0\u6e7f\u6a21\u5757\u3001\u5168\u5c4b\u5168\u611f\u667a\u80fd\u8054\u52a8<\/li>\n<li>\u4e94\u6052\u5efa\u6210\u4eae\u70b9\uff1a\n<ol class=\"wp-block-list\">\n<li>\u5206\u5c42\u5206\u9f84\u4e94\u6052\u53c2\u6570\uff0c\u8001\u4eba\u5367\u5ba4\u6052\u6e29 22\u2103\u3001\u513f\u7ae5\u623f\u4f4e\u566a\u97f3\u6a21\u5f0f\uff1b<\/li>\n<li>\u5168\u5c4b 15 \u53f0\u5185\u673a\u5168\u90e8\u642d\u8f7d PE \u51c0\u5316\uff0c\u5ba4\u5185 TVOC \u957f\u671f\u63a5\u8fd1 0\uff1b<\/li>\n<li>\u72ec\u7acb\u52a0\u6e7f\u6a21\u5757\u89e3\u51b3\u6210\u90fd\u51ac\u5b63\u5e72\u71e5\uff0c\u6e7f\u5ea6\u7a33\u5b9a 50% \u5de6\u53f3\uff1b<\/li>\n<li>4 \u5e74\u6301\u7eed\u80fd\u8017\u8ddf\u8e2a\uff0c\u540c\u6237\u578b\u5bf9\u6807\u8282\u80fd 40% \u4ee5\u4e0a\uff1b<\/li>\n<\/ol>\n<\/li>\n<li>\u9002\u914d\u624b\u518c\u77e5\u8bc6\u70b9\uff1a\u5927\u5b85\u591a\u7cfb\u7edf\u590d\u5408\u4e94\u3001\u52a0\u6e7f\u7cfb\u7edf\u9009\u578b\u3001\u957f\u5468\u671f\u80fd\u8017\u8ddf\u8e2a\u3001\u591a\u573a\u666f\u667a\u80fd\u6a21\u5f0f<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b 13 \u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u81ea\u5efa\u623f\u5929\u6c34\u5730\u6c34\u4e94\u6052<\/h3>\n<p class=\"wp-block-paragraph\">\u6848\u4f8b\u8be6\u60c5\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=2756\">\u5927\u6797\u9547\u81ea\u5efa\u623f\u5929\u6c34\u5730\u6c34\u4e94\u6052 \u00b7 \u6848\u4f8b\u8be6\u60c5<\/a><\/p>\n<ul class=\"wp-block-list\">\n<li>\u6237\u578b\u4e09\u5c42\u81ea\u5efa\u623f\uff0c\u4e8c\u697c\u5c45\u4f4f\u9762\u79ef 183\u33a1\uff0c\u65e0\u5916\u5899\u4fdd\u6e29\u8001\u623f\u6539\u9020<\/li>\n<li>\u5168\u5957\u4e94\u6052\u914d\u7f6e\uff1a\u65e5\u7acb\u6c34\u5885\u9002 RAS-225 \u5927\u673a\u578b\u300110 \u56de\u8def\u5730\u6696\u3001\u5929\u51c0 350 \u98ce\u91cf\u9664\u6e7f\u65b0\u98ce\u3001\u72ec\u7acb\u6052\u6e29\u70ed\u6c34<\/li>\n<li>\u4e94\u6052\u5efa\u6210\u4eae\u70b9\uff1a\n<ol class=\"wp-block-list\">\n<li>\u8001\u623f\u4fdd\u6e29\u7f3a\u5931\u4e13\u9879\u8d1f\u8377\u653e\u5927\u8bbe\u8ba1\uff0c183% \u5408\u7406\u8d85\u914d\u4fdd\u969c\u6781\u7aef\u51ac\u590f\u6548\u679c\uff1b<\/li>\n<li>\u65b0\u98ce\u5927\u6362\u6c14\u91cf\uff0c\u81ea\u5efa\u623f\u901a\u98ce\u5dee\u3001\u7532\u919b\u5feb\u901f\u7f6e\u6362\uff1b<\/li>\n<li>\u6574\u5957\u4e00\u673a\u5b9e\u73b0\u5236\u51b7\u3001\u91c7\u6696\u3001\u751f\u6d3b\u70ed\u6c34\u4e09\u5927\u529f\u80fd\uff0c\u642d\u914d\u65b0\u98ce\u5b8c\u6210\u4e94\u7ef4\u73af\u5883\u63a7\u5236\uff1b<\/li>\n<\/ol>\n<\/li>\n<li>\u9002\u914d\u624b\u518c\u77e5\u8bc6\u70b9\uff1a\u8001\u623f\u6539\u9020\u4e94\u6052\u3001\u9ad8\u8d85\u914d\u7387\u6c34\u7cfb\u7edf\u3001\u65e0\u56f4\u62a4\u5efa\u7b51\u8d1f\u8377\u8ba1\u7b97<\/li>\n<\/ul>\n<div style=\"margin:30px 0;padding:20px;border:1px solid #eee;border-radius:10;\">\n<h4 style=\"margin-top:0;\">\u4e94\u6052\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\u76f4\u8fbe\uff08\u6210\u90fd\u5404\u7247\u533a\uff09<\/h4>\n<p style=\"line-height:2;\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=5809\">\u9e93\u6e56\u6c84\u5cb8157\u33a1\u513f\u7ae5\u4e94\u6052\u5927\u5e73\u5c42<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u5929\u5e9c\u516c\u9986292\u33a1\u522b\u5885\u590d\u5408\u4e94\u6052<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2665\">\u851a\u84dd\u5361\u5730\u4e9a\u6bcd\u5a74\u4e94\u6052\u65b9\u6848<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=448\">\u548c\u8d35\u5357\u5c71600\u33a1\u72ec\u680b\u4e94\u6052<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2756\">\u5927\u6797\u9547\u81ea\u5efa\u623f\u5929\u6c34\u5730\u6c34\u4e94\u6052<\/a>\n<\/p>\n<p style=\"font-size:13;color:#666;\">\u5168\u90e8\u6848\u4f8b\u5747\u542bCAD\u56fe\u7eb8\u3001\u5b8c\u6574\u65bd\u5de5\u5b9e\u62cd\u3001\u4e94\u7ef4\u6e29\u6e7f\u5ea6\u9a8c\u6536\u5b9e\u6d4b\u6570\u636e\uff0c\u53ef\u9884\u7ea6\u5230\u5e97\u67e5\u9605\u7eb8\u8d28\u5b8c\u6574\u6863\u6848<\/p>\n<\/div>\n<div style=\"margin:30px 0;padding:20px;background:#f7f8fa;border-radius:10;\">\n<h3 style=\"font-size:17;margin:0 0 16px 0;color:#222;text-align:center;\">\u9f99\u8109\u6696\u901a \u65e5\u7acb\u4e94\u5927\u5b98\u65b9\u6388\u6743\u8d44\u8d28<\/h3>\n<div style=\"display:grid;grid-template-columns:repeat(5,1fr);gap:8px;\">\n<!--1 \u7279\u9080\u5b89\u88c5\u5546--><\/p>\n<div>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"2026\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u7279\u9080\u5b89\u88c5\u5355\u4f4d\u8d44\u8d28\" loading=\"lazy\" style=\"width:100%;border-radius:4;\"><\/p>\n<p style=\"font-size:11;text-align:center;margin:4px 0 0;color:#555;\">\u7279\u9080\u5b89\u88c5\u5546<\/p>\n<\/div>\n<p><!--2 24\u91d1\u724c--><\/p>\n<div>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"2024\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u5546\u8bc1\u4e66\" loading=\"lazy\" style=\"width:100%;border-radius:4;\"><\/p>\n<p style=\"font-size:11;text-align:center;margin:4px 0 0;color:#555;\">\u91d1\u724c\u5b89\u88c5\u5546<\/p>\n<\/div>\n<p><!--3 \u6c34\u5885\u9002\u7ecf\u9500--><\/p>\n<div>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u7279\u7ea6\u7ecf\u9500\u8bc1\" loading=\"lazy\" style=\"width:100%;border-radius:4;\"><\/p>\n<p style=\"font-size:11;text-align:center;margin:4px 0 0;color:#555;\">\u6c34\u5885\u9002\u7ecf\u9500\u5546<\/p>\n<\/div>\n<p><!--4 \u4e2d\u592e\u7a7a\u8c03\u7ecf\u9500--><\/p>\n<div>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"2026\u65e5\u7acb\u591a\u8054\u673a\u7279\u7ea6\u7ecf\u9500\u5546\u8d44\u8d28\" loading=\"lazy\" style=\"width:100%;border-radius:4;\"><\/p>\n<p style=\"font-size:11;text-align:center;margin:4px 0 0;color:#555;\">\u4e2d\u592e\u7a7a\u8c03\u7ecf\u9500\u5546<\/p>\n<\/div>\n<p><!--5 \u94bb\u77f3\u5b89\u88c5\u5546--><\/p>\n<div>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"2026\u65e5\u7acb\u94bb\u77f3\u7cbe\u5de5\u5b89\u88c5\u5546\u8bc1\u4e66\" loading=\"lazy\" style=\"width:100%;border-radius:4;\"><\/p>\n<p style=\"font-size:11;text-align:center;margin:4px 0 0;color:#555;\">\u94bb\u77f3\u5b89\u88c5\u5546<\/p>\n<\/div>\n<\/div>\n<p style=\"margin:14px 0 0;font-size:13;color:#555;line-height:1.6;text-align:center;\">\n\u8d44\u8d28\u6709\u6548\u671f2026.1.1-12.31\uff0c\u5168\u7cfb\u65e5\u7acb\u8bbe\u5907\u539f\u5382\u6b63\u54c1 \u6388\u6743\u539f\u4ef6\u53ef\u5728\u95e8\u5e97\u67e5\u9605\n<\/p>\n<\/div>\n<h2 class=\"wp-block-heading\">\u7b2c\u516b\u90e8\u5206\uff1a\u5ba2\u6237\u6c9f\u901a\u4e0e\u65b9\u6848\u5448\u73b0<\/h2>\n<h3 class=\"wp-block-heading\">8.1 \u4e94\u6052 vs \u4e24\u8054\u4f9b\u600e\u4e48\u8bb2\uff1f<\/h3>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u4e24\u8054\u4f9b\u89e3\u51b3\u7684\u662f\u2018\u51b7\u6696+\u5730\u6696\u2019\u7684\u57fa\u7840\u9700\u6c42\uff0c\u4e94\u6052\u89e3\u51b3\u7684\u662f\u2018\u6e29\u6e7f\u6c27\u6d01\u9759\u2019\u7684\u5168\u7ef4\u8212\u9002\u3002\u4e24\u8054\u4f9b\u662f\u529f\u80fd\u673a\uff0c\u4e94\u6052\u662f\u667a\u80fd\u673a\u3002\u201d<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">8.2 \u5168\u7a7a\u6c14 vs \u8f90\u5c04 vs \u590d\u5408\u5f0f\u600e\u4e48\u9009\uff1f<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u5ba2\u6237\u9700\u6c42<\/strong><\/td>\n<td><strong>\u63a8\u8350\u65b9\u6848<\/strong><\/td>\n<td><strong>\u7406\u7531<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8ffd\u6c42\u6781\u81f4\u8212\u9002\uff0c\u9884\u7b97\u5145\u8db3<\/td>\n<td>\u8f90\u5c04\u7cfb\u7edf<\/td>\n<td>\u5782\u76f4\u6e29\u5dee\u00b11\u2103\uff0c\u65e0\u98ce\u611f<\/td>\n<\/tr>\n<tr>\n<td>\u9700\u8981\u5feb\u901f\u54cd\u5e94\uff0c\u522b\u5885\u5927\u5b85<\/td>\n<td>\u5168\u7a7a\u6c14\u7cfb\u7edf<\/td>\n<td>\u6362\u6c14\u6b21\u6570\u9ad8\uff0c\u54cd\u5e94\u5feb<\/td>\n<\/tr>\n<tr>\n<td>\u517c\u987e\u8212\u9002\u4e0e\u7075\u6d3b<\/td>\n<td>\u590d\u5408\u5f0f\u7cfb\u7edf<\/td>\n<td>\u5367\u5ba4\u8f90\u5c04+\u5ba2\u5385\u98ce\u76d8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">8.3 \u5ba2\u6237\u5e38\u89c1\u7591\u95ee\u5e94\u7b54<\/h3>\n<p class=\"wp-block-paragraph\"><strong>Q\uff1a\u201c\u4e94\u6052\u662f\u4e0d\u662f\u667a\u5546\u7a0e\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u4e94\u6052\u6709\u56fd\u5bb6\u6807\u51c6\u2014\u2014T\/CAS 1009-2025\u5df2\u7ecf\u53d1\u5e03\u3002\u4e0d\u662f\u6982\u5ff5\uff0c\u662f\u53ef\u91cf\u5316\u3001\u53ef\u9a8c\u6536\u7684\u6807\u51c6\u7cfb\u7edf\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>Q\uff1a\u201c\u4e94\u6052\u548c\u4e24\u8054\u4f9b\u5dee\u591a\u5c11\u94b1\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u4e94\u6052\u589e\u52a0\u4e86\u9664\u6e7f\u65b0\u98ce\u3001\u52a0\u6e7f\u6a21\u5757\u3001\u667a\u63a7\u7cfb\u7edf\uff0c\u5e38\u89c4\u9762\u79ef\u4e0b\u6bcf\u5e73\u7c73\u7ea6800-1500\u5143\u3002\u6362\u6765\u7684\u662f\u5168\u5e74\u6052\u6e7f\u3001\u6052\u6c27\u3001\u6052\u6d01\u3002\u9762\u79ef\u8d8a\u5c0f\uff0c\u8fd9\u90e8\u5206\u56fa\u5b9a\u6295\u5165\u644a\u5230\u6bcf\u5e73\u7c73\u8d8a\u9ad8\uff0c90 \u5e73\u65b9\u7c73\u4ee5\u4e0b\u8981\u5148\u7b97\u6e05\u8d26\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\"><strong>Q\uff1a\u201c\u4e3a\u4ec0\u4e48\u4e94\u6052\u8fd8\u8981\u6709\u98ce\uff1f\u201d<\/strong><\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u201c\u4e13\u4e1a\u8f66\u624b\u5ba4\u5185373W\u53ea\u80fd\u9a915-15\u5206\u949f\uff0c\u6237\u5916\u80fd\u9a911\u5c0f\u65f6\u3002\u5dee\u5728\u98ce\u2014\u2014\u5e26\u8d70\u70ed\u91cf\u3002\u5b8c\u5168\u65e0\u98ce\u4f1a\u5f62\u6210\u2018\u5fae\u6c14\u5019\u5305\u56f4\u5708\u2019\uff0c\u4e94\u6052\u7684\u5fae\u98ce\u5faa\u73af\u6253\u7834\u70ed\u8fb9\u754c\u5c42\uff0c\u98ce\u901f\u6781\u4f4e\u60a8\u611f\u89c9\u4e0d\u5230\u3002\u201d<\/p>\n<\/blockquote>\n<p class=\"wp-block-paragraph\">Q\uff1a\u6210\u90fd\u9e93\u6e56\u5927\u5e73\u5c42\u9002\u5408\u5929\u6c34\u5730\u6c34\u8fd8\u662f\u5929\u6c1f\u5730\u6c34\u4e94\u6052\uff1f A\uff1a\u9e93\u6e56\u9ad8\u697c\u5c42\u3001\u5bb6\u4e2d\u6709\u8001\u4eba\u5c0f\u5b69\u4f18\u5148\u5929\u6c34\u5730\u6c34\u65e0\u98ce\u4e94\u6052\uff1b\u521a\u9700\u4e2d\u5c0f\u6237\u578b\u53ef\u9009\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u642d\u914d\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff0c\u4e24\u5957\u65b9\u6848\u5747\u53ef\u5b9e\u73b0\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\uff0c\u53ef\u9884\u7ea6\u514d\u8d39\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u3002<\/p>\n<p class=\"wp-block-paragraph\">Q\uff1a\u6210\u90fd\u6885\u96e8\u5b63\u505a\u4e94\u6052\u7cfb\u7edf\u8fd8\u4f1a\u5899\u9762\u7ed3\u9732\u5417\uff1f A\uff1a\u9f99\u8109\u4e94\u6052\u5168\u90e8\u914d\u5957\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff0c\u8bbe\u8ba1\u65b0\u98ce\u51fa\u542b\u6e7f\u91cf\u22648g\/kg\uff0c\u5339\u914d\u6210\u90fd\u9ad8\u6e7f\u6c14\u5019\uff0c\u8f90\u5c04\u5730\u6696 \/ \u8f90\u5c04\u677f\u4e0d\u4f1a\u51fa\u73b0\u7ed3\u73e0\u3001\u6ef4\u6c34\u95ee\u9898\uff0c\u6709\u5b8c\u6574\u9e93\u6e56\u3001\u851a\u84dd\u5361\u5730\u4e9a\u5b9e\u6d4b\u6570\u636e\u4f50\u8bc1\u3002 <\/p>\n<p class=\"wp-block-paragraph\">Q\uff1a\u4e94\u6052\u7cfb\u7edf\u4e00\u5e74\u80fd\u8017\u5927\u6982\u591a\u5c11\uff1f\u9e93\u6e56 157\u33a1\u5e73\u5c42\u53c2\u8003\uff1f A\uff1a\u9e93\u6e56 157\u33a1\u5929\u6c34\u5730\u6c34\u4e94\u6052\uff0c\u5168\u5e74\u5236\u51b7 + \u91c7\u6696 + \u65b0\u98ce\u7efc\u5408\u7535\u8d39 7000-9000 \u5143 \/ \u5e74\uff0c\u5bf9\u6bd4\u9505\u7089\u91c7\u6696\u65b9\u6848\u5e74\u7701 40% \u5de6\u53f3\uff0c\u7b7e\u7ea6\u81ea\u52a8\u7eb3\u5165 10 \u5e74\u80fd\u6e90\u8ddf\u8e2a\u8ba1\u5212\u3002 <\/p>\n<p class=\"wp-block-paragraph\">Q\uff1a\u5bb6\u91cc\u6709\u8fc7\u654f\u5c0f\u670b\u53cb\uff0c\u4e94\u6052\u6bd4\u666e\u901a\u7a7a\u8c03\u4f18\u52bf\u5728\u54ea\uff1f A\uff1a\u4e94\u6052\u7cfb\u7edf\u5168\u5c4b\u6362\u6c14 6-11 \u6b21\/\u5c0f\u65f6\uff08\u6309 15 \u5e73\u65b9\u7c73\u623f\u95f4\u7b97\uff0c\u76f8\u5f53\u4e8e\u6bcf\u5c0f\u65f6 240-500 \u7acb\u65b9\u7c73\u98ce\u91cf\uff09\uff0c\u914d H11 \u7ea7\u957f\u6548\u8fc7\u6ee4\uff0c\u65e0\u51b7\u98ce\u76f4\u5439\uff0c\u5168\u5e74\u6e29\u6e7f\u5ea6\u7a33\u5b9a\u5728\u4eba\u4f53\u8212\u9002\u9ec4\u91d1\u533a\u95f4\uff0c\u5927\u5e45\u964d\u4f4e\u547c\u5438\u9053\u8fc7\u654f\u53d1\u4f5c\u6982\u7387\uff0c\u9e93\u6e56\u6c84\u5cb8\u4e24\u5957\u540c\u6237\u578b\u6709\u513f\u7ae5\u7684\u5bb6\u5ead\u5df2\u5b8c\u5de5\uff0c\u53ef\u5b9e\u5730\u53c2\u89c2\u3002<\/p>\n<h2 class=\"wp-block-heading\">\u7b2c\u4e5d\u90e8\u5206\uff1a\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/h2>\n<h3 class=\"wp-block-heading\">9.1 \u4e94\u6052\u7cfb\u7edf\u5e38\u89c1\u552e\u540e\u95ee\u9898<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898\u73b0\u8c61<\/strong><\/td>\n<td><strong>\u53ef\u80fd\u539f\u56e0<\/strong><\/td>\n<td><strong>\u6392\u67e5\u65b9\u5411<\/strong><\/td>\n<td><strong>\u89e3\u51b3\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u677f\u7ed3\u9732\u6ef4\u6c34<\/td>\n<td>\u65b0\u98ce\u9664\u6e7f\u80fd\u529b\u4e0d\u8db3\u3001\u6c34\u6e29\u8fc7\u4f4e<\/td>\n<td>\u68c0\u67e5\u65b0\u98ce\u542b\u6e7f\u91cf\u3001\u4f9b\u6c34\u6e29\u5ea6<\/td>\n<td>\u589e\u5f3a\u9664\u6e7f\u3001\u8c03\u9ad8\u6c34\u6e29<\/td>\n<\/tr>\n<tr>\n<td>\u611f\u89c9\u95f7\u3001CO\u2082\u9ad8<\/td>\n<td>\u65b0\u98ce\u91cf\u4e0d\u8db3\u3001\u6362\u6c14\u6b21\u6570\u4f4e<\/td>\n<td>\u68c0\u67e5\u65b0\u98ce\u98ce\u91cf\u3001\u98ce\u53e3\u906e\u6321<\/td>\n<td>\u52a0\u5927\u65b0\u98ce\u3001\u6e05\u6d01\u98ce\u53e3<\/td>\n<\/tr>\n<tr>\n<td>\u6e7f\u5ea6\u5931\u63a7<\/td>\n<td>\u9664\u6e7f\/\u52a0\u6e7f\u6a21\u5757\u6545\u969c<\/td>\n<td>\u68c0\u67e5\u6a21\u5757\u8fd0\u884c\u72b6\u6001<\/td>\n<td>\u7ef4\u4fee\u6216\u66f4\u6362\u6a21\u5757<\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u5ea6\u5206\u5c42\/\u4e0d\u5747\u5300<\/td>\n<td>\u7a7a\u6c14\u5faa\u73af\u4e0d\u8db3<\/td>\n<td>\u68c0\u67e5\u5faa\u73af\u98ce\u91cf\u3001\u98ce\u53e3\u4f4d\u7f6e<\/td>\n<td>\u52a0\u5927\u5faa\u73af\u3001\u4f18\u5316\u6c14\u6d41<\/td>\n<\/tr>\n<tr>\n<td>\u566a\u97f3\u5927<\/td>\n<td>\u98ce\u7ba1\u98ce\u901f\u8fc7\u9ad8\u3001\u4e3b\u673a\u5171\u632f<\/td>\n<td>\u68c0\u67e5\u98ce\u901f\u3001\u51cf\u9707\u63aa\u65bd<\/td>\n<td>\u964d\u4f4e\u98ce\u901f\u3001\u52a0\u88c5\u6d88\u97f3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">9.2 \u7cfb\u7edf\u6027\u95ee\u9898\u6839\u6e90\uff08\u8bbe\u8ba1\u9636\u6bb5\uff09<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898\u6839\u6e90<\/strong><\/td>\n<td><strong>\u552e\u540e\u8868\u73b0<\/strong><\/td>\n<td><strong>\u8bbe\u8ba1\u9636\u6bb5\u9884\u9632\u63aa\u65bd<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce\u9664\u6e7f\u80fd\u529b\u4e0e\u6c14\u5019\u4e0d\u5339\u914d<\/td>\n<td>\u8f90\u5c04\u677f\u7ed3\u9732\u3001\u6e7f\u5ea6\u5931\u63a7<\/td>\n<td>\u6309\u5f53\u5730\u590f\u5b63\u53c2\u6570\u9009\u578b\uff0c\u51fa\u98ce\u542b\u6e7f\u91cf\u22648g\/kg<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u6c14\u6b21\u6570\u4e0d\u8db3<\/td>\n<td>\u95f7\u3001CO\u2082\u9ad8<\/td>\n<td>\u4e94\u6052\u7cfb\u7edf\u6362\u6c146-11\u6b21\/h<\/td>\n<\/tr>\n<tr>\n<td>\u6c14\u6d41\u7ec4\u7ec7\u4e0d\u5f53<\/td>\n<td>\u6e29\u5ea6\u5206\u5c42<\/td>\n<td>CFD\u6a21\u62df\uff0c\u7f6e\u6362\u901a\u98ce<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u8054\u52a8\u7f3a\u5931<\/td>\n<td>\u5404\u5b50\u7cfb\u7edf\u5404\u81ea\u4e3a\u653f<\/td>\n<td>\u5168\u5c4b\u5168\u611f\u96c6\u6210\u63a7\u5236<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">9.3 \u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7ef4\u4fdd\u9879\u76ee<\/strong><\/td>\n<td><strong>\u5468\u671f<\/strong><\/td>\n<td><strong>\u5185\u5bb9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u65b0\u98ce\u6ee4\u7f51\u66f4\u6362<\/td>\n<td>3-6\u4e2a\u6708<\/td>\n<td>HEPA\u3001\u6d3b\u6027\u70ad\u6ee4\u7f51<\/td>\n<\/tr>\n<tr>\n<td>\u9664\u6e7f\u6a21\u5757\u6e05\u6d17<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u51b7\u51dd\u6c34\u76d8\u3001\u6362\u70ed\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u52a0\u6e7f\u6a21\u5757\u6e05\u6d17<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u6c34\u7bb1\u3001\u6e7f\u819c<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u7ba1\u6c14\u5bc6\u6027\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u6f0f\u98ce\u70b9<\/td>\n<\/tr>\n<tr>\n<td>\u4f20\u611f\u5668\u6821\u51c6<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u6e29\u6e7f\u5ea6\u3001CO\u2082\u3001PM2.5<\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u677f\u8868\u9762\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u6709\u65e0\u7ed3\u9732\u75d5\u8ff9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">9.4 \u9632\u7ed3\u9732\u8bbe\u8ba1\u81ea\u68c0\u6e05\u5355\uff08\u7075\u9b42\u4e09\u95ee\uff09<\/h3>\n<ol class=\"wp-block-list\">\n<li><strong>\u6570\u636e\u95ee\u9898<\/strong>\uff1a\u65b0\u98ce\u673a\u7ec4\u5728\u5f53\u5730\u590f\u5b63\u7a7a\u8c03\u5ba4\u5916\u53c2\u6570\u4e0b\uff0c\u51fa\u98ce\u7edd\u5bf9\u542b\u6e7f\u91cf\u662f\u591a\u5c11\uff1f<\/li>\n<li><strong>\u63a7\u5236\u95ee\u9898<\/strong>\uff1a\u6781\u7aef\u9ad8\u6e29\u9ad8\u6e7f\u65f6\uff0c\u7cfb\u7edf\u5982\u4f55\u52a8\u6001\u8c03\u8282\uff1f\u662f\u8c03\u9ad8\u6c34\u6e29\u8fd8\u662f\u76f4\u63a5\u5207\u65ad\uff1f<\/li>\n<li><strong>\u5197\u4f59\u95ee\u9898<\/strong>\uff1a\u65b0\u98ce\u673a\u6545\u969c\u65f6\uff0c\u6709\u65e0\u5907\u7528\u65b9\u6848\u6216\u62a5\u8b66\u673a\u5236\uff1f<\/li>\n<\/ol>\n<h2 class=\"wp-block-heading\">\u4e94\u6052\u7cfb\u7edf\u5e38\u89c1\u95ee\u9898<\/h2>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7cfb\u7edf\u5230\u5e95\u662f\u4ec0\u4e48\uff1f\u8ddf\u300c\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u300d\u662f\u4e00\u56de\u4e8b\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e0d\u5b8c\u5168\u662f\u4e00\u56de\u4e8b\u3002\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u662f\u4e09\u4e2a\u6307\u6807\uff0c\u4e94\u6052\u5728\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001\u542b\u6c27\u91cf\u4e4b\u5916\uff0c\u53c8\u52a0\u4e86\u6d01\u51c0\u5ea6\u548c\u9759\u97f3\u4e24\u4e2a\u7ef4\u5ea6\u2014\u2014\u6d01\u51c0\u5ea6\u770b PM2.5 \u548c\u8fc7\u6ee4\u7b49\u7ea7\uff0c\u9759\u97f3\u770b\u98ce\u53e3\u566a\u97f3\u3002\u884c\u4e1a\u91cc\u4e5f\u6709\u628a\u300c\u667a\u63a7\u300d\u7b97\u6210\u7b2c\u516d\u9879\u7684\uff0c\u8bf4\u6cd5\u4e0d\u7edf\u4e00\uff0c\u672c\u518c\u6309\u4e94\u4e2a\u7ef4\u5ea6\u8bb2\u3002\u6240\u4ee5\u53ea\u505a\u5230\u6052\u6e29\u6052\u6e7f\u6052\u6c27\uff0c\u90a3\u662f\u4e09\u6052\uff0c\u4e0d\u662f\u4e94\u6052\u3002\u672c\u518c\u7b2c\u4e8c\u90e8\u5206\u7ed9\u6bcf\u4e2a\u7ef4\u5ea6\u5355\u72ec\u5217\u4e86\u6307\u6807\u533a\u95f4\u548c\u505a\u6cd5\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u53ea\u505a\u8f90\u5c04\u5730\u6696\u52a0\u4e00\u53f0\u65b0\u98ce\uff0c\u7b97\u4e0d\u7b97\u4e94\u6052\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e0d\u7b97\uff0c\u7f3a\u7684\u662f\u63a7\u5236\u8fd9\u4e00\u5c42\u3002\u8f90\u5c04\u5730\u6696\u7ba1\u6c34\u6e29\u3001\u65b0\u98ce\u7ba1\u6362\u6c14\uff0c\u4e24\u5957\u7cfb\u7edf\u5404\u5e72\u5404\u7684\uff0c\u4e2d\u95f4\u6ca1\u6709\u4eba\u7edf\u4e00\u534f\u8c03\uff1a\u6e7f\u5ea6\u9ad8\u4e86\u65b0\u98ce\u8981\u4e0d\u8981\u52a0\u5927\u3001\u5730\u6696\u6c34\u6e29\u8981\u4e0d\u8981\u8ddf\u7740\u964d\uff0c\u8fd9\u4e24\u4ef6\u4e8b\u5f97\u6709\u4eba\u5728\u4e2d\u95f4\u8c03\u5ea6\u3002\u4e94\u6052\u8981\u6c42\u51e0\u4e2a\u7ef4\u5ea6\u7531\u4e00\u4e2a\u5e73\u53f0\u540c\u65f6\u7ba1\uff0c\u672c\u518c 4.6 \u8bb2\u7684\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\u5c31\u662f\u8fd9\u4e00\u5c42\u3002\u8bbe\u5907\u9f50\u4e0d\u7b49\u4e8e\u7cfb\u7edf\u6210\u7acb\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u591a\u5927\u9762\u79ef\u9002\u5408\u505a\u4e94\u6052\uff1f\u5c0f\u6237\u578b\u80fd\u505a\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u6280\u672f\u4e0a\u6ca1\u6709\u4e0b\u9650\uff0c\u7ecf\u6d4e\u4e0a\u6709\u3002\u4e94\u6052\u8981\u6bd4\u666e\u901a\u4e24\u8054\u4f9b\u591a\u914d\u9664\u6e7f\u65b0\u98ce\u3001\u52a0\u6e7f\u6a21\u5757\u3001\u5206\u533a\u63a7\u5236\u548c\u4e00\u5957\u667a\u63a7\uff0c\u8fd9\u90e8\u5206\u6295\u5165\u8ddf\u9762\u79ef\u5173\u7cfb\u4e0d\u5927\uff0c\u4ee5\u56fa\u5b9a\u6210\u672c\u4e3a\u4e3b\uff0c\u6240\u4ee5\u9762\u79ef\u8d8a\u5c0f\uff0c\u6bcf\u5e73\u7c73\u644a\u5f97\u8d8a\u8d35\u3002\u6210\u90fd\u8fd9\u8fb9\u505a\u5f97\u6bd4\u8f83\u591a\u7684\u662f 120 \u5e73\u65b9\u7c73\u4ee5\u4e0a\u7684\u5927\u5e73\u5c42\u548c\u522b\u5885\uff1b90 \u5e73\u65b9\u7c73\u4ee5\u4e0b\u5982\u679c\u53ea\u662f\u60f3\u8981\u6052\u6e29\u6052\u6e7f\uff0c\u4e24\u8054\u4f9b\u914d\u4e00\u53f0\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\u901a\u5e38\u66f4\u5212\u7b97\u3002\u672c\u518c 8.1 \u4e13\u95e8\u8bb2\u4e94\u6052\u548c\u4e24\u8054\u4f9b\u600e\u4e48\u5206\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7684\u300c\u6052\u6e29\u300d\u8ddf\u666e\u901a\u7a7a\u8c03\u7684\u300c\u6052\u6e29\u300d\u5dee\u5728\u54ea\uff1f<\/summary>\n<p>\u7b54\uff1a\u5dee\u5728\u6ce2\u52a8\u5e45\u5ea6\u548c\u98ce\u7684\u611f\u53d7\u3002\u666e\u901a\u7a7a\u8c03\u9760\u538b\u7f29\u673a\u542f\u505c\u63a7\u5236\u5ba4\u6e29\uff0c\u6e29\u5dee\u4e00\u822c\u5728\u6b63\u8d1f 2 \u5ea6\u4e0a\u4e0b\uff0c\u98ce\u4ece\u98ce\u53e3\u76f4\u5439\u5230\u4eba\u8eab\u4e0a\uff1b\u4e94\u6052\u8d70\u8f90\u5c04\u672b\u7aef\u52a0\u4f4e\u901f\u98ce\uff0c\u5ba4\u5185\u6e29\u5dee\u53ef\u4ee5\u538b\u5230\u6b63\u8d1f 0.5 \u5ea6\u4ee5\u5185\uff0c\u98ce\u53e3\u98ce\u901f\u4f4e\u5230\u57fa\u672c\u611f\u89c9\u4e0d\u5230\u3002\u672c\u518c 2.1 \u8bb2\u6052\u6e29\u7684\u5177\u4f53\u505a\u6cd5\uff0c2.6 \u5355\u72ec\u8bb2\u98ce\u611f\u8fd9\u4ef6\u4e8b\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7cfb\u7edf\u7684\u94b1\u4e3b\u8981\u82b1\u5728\u54ea\u51e0\u5757\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e09\u5757\uff1a\u672b\u7aef\uff08\u8f90\u5c04\u5730\u6696\u6216\u8f90\u5c04\u677f\uff09\u3001\u7a7a\u6c14\u5904\u7406\uff08\u9664\u6e7f\u65b0\u98ce\u3001\u52a0\u6e7f\u3001\u8fc7\u6ee4\uff09\u3001\u63a7\u5236\uff08\u5206\u533a\u4e0e\u667a\u63a7\u5e73\u53f0\uff09\u3002\u6bd4\u666e\u901a\u4e24\u8054\u4f9b\u591a\u51fa\u6765\u7684\u90e8\u5206\uff0c\u4e3b\u8981\u5c31\u5728\u7a7a\u6c14\u5904\u7406\u548c\u63a7\u5236\u8fd9\u4e24\u5757\u3002\u6bcf\u5e73\u7c73\u5177\u4f53\u591a\u5c11\u94b1\uff0c\u53d6\u51b3\u4e8e\u9762\u79ef\u3001\u5c42\u9ad8\u3001\u8981\u4e0d\u8981\u5168\u5c4b\u8f90\u5c04\u677f\u3001\u5212\u51e0\u4e2a\u5206\u533a\uff0c\u672c\u518c 8.3 \u7ed9\u4e86\u4e00\u4e2a\u5927\u81f4\u533a\u95f4\u3002\u6b63\u5f0f\u62a5\u4ef7\u6309\u6bcf\u6237\u5b9e\u6d4b\u51b7\u70ed\u8d1f\u8377\u7b97\uff0c\u4e0d\u5957\u6a21\u677f\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u80fd\u5206\u623f\u95f4\u63a7\u5236\u5417\uff1f\u8fd8\u662f\u4e00\u5f00\u5168\u5f00\uff1f<\/summary>\n<p>\u7b54\uff1a\u80fd\u5206\u3002\u5206\u533a\u63a7\u5236\u662f\u672c\u518c 4.5 \u7684\u5185\u5bb9\uff0c\u6309\u623f\u95f4\u6216\u6309\u697c\u5c42\u5212\u533a\uff0c\u6bcf\u4e2a\u533a\u72ec\u7acb\u6d4b\u6e29\u548c\u8c03\u8282\u3002\u4f46\u6709\u4e00\u70b9\u8981\u63d0\u524d\u8bf4\u6e05\u695a\uff1a\u8f90\u5c04\u672b\u7aef\u6709\u70ed\u60f0\u6027\uff0c\u5f00\u5173\u4e0d\u662f\u5373\u65f6\u7684\uff0c\u8c03\u6e29\u5f97\u63d0\u524d\u51e0\u4e2a\u5c0f\u65f6\uff0c\u6240\u4ee5\u6b63\u786e\u7684\u7528\u6cd5\u662f\u5e38\u5e74\u5f00\u7740\u3001\u5c0f\u5e45\u8c03\u8282\uff0c\u800c\u4e0d\u662f\u50cf\u7a7a\u8c03\u90a3\u6837\u4eba\u8d70\u5173\u673a\u3002\u8fd9\u4e00\u70b9\u5728\u5ba2\u6237\u6c9f\u901a\u65f6\u5bb9\u6613\u6f0f\u6389\uff0c\u672c\u518c 8.3 \u6709\u5e94\u7b54\u53e3\u5f84\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7684\u9664\u6e7f\u65b0\u98ce\u8ddf\u666e\u901a\u65b0\u98ce\u6709\u4ec0\u4e48\u4e0d\u4e00\u6837\uff1f<\/summary>\n<p>\u7b54\uff1a\u666e\u901a\u65b0\u98ce\u53ea\u6362\u6c14\uff0c\u628a\u5ba4\u5916\u7a7a\u6c14\u5f15\u8fdb\u5ba4\u5185\uff0c\u9664\u6e7f\u9760\u7a7a\u8c03\u987a\u5e26\uff1b\u4e94\u6052\u7684\u9664\u6e7f\u65b0\u98ce\u662f\u5148\u628a\u65b0\u98ce\u5904\u7406\u5230\u8bbe\u5b9a\u542b\u6e7f\u91cf\u518d\u9001\u8fdb\u6765\uff0c\u672c\u518c\u7684\u8bbe\u8ba1\u53d6\u503c\u662f\u9001\u98ce\u542b\u6e7f\u91cf\u4e0d\u9ad8\u4e8e 8 \u514b\u6bcf\u5343\u514b\u3002\u6210\u90fd\u6885\u96e8\u5b63\u5ba4\u5916\u542b\u6e7f\u91cf\u80fd\u5230 18 \u81f3 20 \u514b\u6bcf\u5343\u514b\uff0c\u76f4\u63a5\u5f15\u8fdb\u6765\u7684\u8bdd\u5ba4\u5185\u6e7f\u5ea6\u538b\u4e0d\u4f4f\uff0c\u8f90\u5c04\u677f\u8868\u9762\u5c31\u4f1a\u7ed3\u9732\u3002\u6240\u4ee5\u8fd9\u5957\u8bbe\u5907\u5728\u6210\u90fd\u4e0d\u662f\u53ef\u9009\u9879\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7684\u8bbe\u5907\u574f\u4e86\uff0c\u4fee\u8d77\u6765\u8981\u62c6\u540a\u9876\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u5e38\u89c4\u7ef4\u62a4\u4e0d\u7528\u3002\u6ee4\u7f51\u66f4\u6362\u3001\u5e38\u89c4\u68c0\u67e5\u90fd\u901a\u8fc7\u9884\u7559\u68c0\u4fee\u53e3\u505a\uff0c\u672c\u518c 6.4 \u65bd\u5de5\u9a8c\u6536\u91cc\u8981\u6c42\u6bcf\u4e2a\u9700\u8981\u7ef4\u62a4\u7684\u8bbe\u5907\u65c1\u8fb9\u7559\u68c0\u4fee\u53e3\uff0c\u4f4d\u7f6e\u548c\u5c3a\u5bf8\u90fd\u6709\u89c4\u5b9a\u3002\u771f\u8981\u62c6\u540a\u9876\u7684\u662f\u98ce\u673a\u3001\u6c34\u6cf5\u8fd9\u7c7b\u5927\u4ef6\u66f4\u6362\uff0c\u6982\u7387\u4f4e\u3002\u6240\u4ee5\u8bbe\u8ba1\u548c\u65bd\u5de5\u9636\u6bb5\u628a\u68c0\u4fee\u53e3\u7559\u5bf9\uff0c\u6bd4\u4e8b\u540e\u4e89\u8bba\u91cd\u8981\u5f97\u591a\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u623f\u5b50\u5df2\u7ecf\u88c5\u4fee\u597d\u4e86\uff0c\u8fd8\u80fd\u52a0\u4e94\u6052\u5417\uff1f<\/summary>\n<p>\u7b54\uff1a\u5168\u5c4b\u4e94\u6052\u57fa\u672c\u4e0d\u884c\u3002\u8f90\u5c04\u672b\u7aef\u8981\u57cb\u5728\u5730\u9762\u6216\u9876\u9762\u91cc\uff0c\u9664\u6e7f\u65b0\u98ce\u7684\u7ba1\u9053\u8981\u8d70\u540a\u9876\uff0c\u90fd\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u88c5\u4fee\u5b8c\u518d\u52a8\u7b49\u4e8e\u91cd\u505a\u3002\u5df2\u7ecf\u88c5\u597d\u7684\u623f\u5b50\u60f3\u6539\u5584\uff0c\u73b0\u5b9e\u7684\u8def\u5f84\u662f\u5c40\u90e8\uff1a\u52a0\u4e00\u53f0\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\u89e3\u51b3\u6e7f\u5ea6\uff0c\u6216\u8005\u7528\u660e\u88c5\u6696\u6c14\u7247\u89e3\u51b3\u91c7\u6696\uff0c\u8fd9\u4e24\u6761\u5728 02 \u53f7\u624b\u518c\u91cc\u6709\u3002\u786e\u5b9e\u60f3\u8981\u5168\u5c4b\u4e94\u6052\uff0c\u5efa\u8bae\u7b49\u4e0b\u6b21\u7ffb\u65b0\u4e00\u8d77\u505a\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7cfb\u7edf\u9a8c\u6536\u770b\u4ec0\u4e48\uff1f\u6709\u6ca1\u6709\u6807\u51c6\u53ef\u4f9d\uff1f<\/summary>\n<p>\u7b54\uff1a\u6709\u6807\u51c6\u3002\u884c\u4e1a\u5c42\u9762\u662f T\/CAS 1009-2025\uff0c\u672c\u518c 1.4 \u6458\u4e86\u8981\u70b9\uff1b\u6307\u6807\u5c42\u9762\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001\u4e8c\u6c27\u5316\u78b3\u3001PM2.5\u3001\u6362\u6c14\u6b21\u6570\u7684\u53d6\u503c\uff0c\u9644\u5f55 B \u6709\u901f\u67e5\u8868\u3002\u5b9e\u9645\u9a8c\u6536\u770b\u4e09\u6837\uff1a\u4e00\u662f\u8fde\u7eed\u51e0\u5929\u7684\u5b9e\u6d4b\u66f2\u7ebf\uff0c\u770b\u8fd9\u51e0\u4e2a\u6570\u6709\u6ca1\u6709\u8d85\u51fa\u533a\u95f4\uff1b\u4e8c\u662f\u98ce\u53e3\u566a\u97f3\u5b9e\u6d4b\uff1b\u4e09\u662f\u9632\u7ed3\u9732\u6d4b\u8bd5\uff0c\u628a\u6c34\u6e29\u62c9\u5230\u8bbe\u8ba1\u503c\u3001\u6e7f\u5ea6\u62c9\u5230\u4e0a\u9650\uff0c\u770b\u8f90\u5c04\u9762\u4f1a\u4e0d\u4f1a\u7ed3\u73e0\u3002\u672c\u518c 9.4 \u6709\u4e00\u4efd\u9632\u7ed3\u9732\u81ea\u68c0\u6e05\u5355\u53ef\u4ee5\u76f4\u63a5\u62ff\u53bb\u7528\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u3001\u4e09\u6052\u3001\u4e24\u8054\u4f9b\u7684\u533a\u522b\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e09\u6052\u662f\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001\u542b\u6c27\u91cf\u4e09\u4e2a\u6307\u6807\u6052\u5b9a\uff1b\u4e94\u6052\u5728\u4e09\u4e2a\u57fa\u7840\u4e0a\u52a0\u4e86\u6d01\u51c0\u5ea6\uff08PM2.5 \u548c\u8fc7\u6ee4\uff09\u548c\u9759\u97f3\uff08\u98ce\u53e3\u566a\u97f3\uff09\u4e24\u4e2a\u7ef4\u5ea6\uff1b\u4e24\u8054\u4f9b\u662f\u300c\u4e00\u5957\u4e3b\u673a\u5e26\u7a7a\u8c03\uff0b\u5730\u6696\u300d\u7684\u7cfb\u7edf\u67b6\u6784\uff0c\u4e0d\u627f\u8bfa\u54ea\u4e2a\u6307\u6807\u6052\u5b9a\u3002\u5173\u7cfb\u4e0a\uff1a\u4e24\u8054\u4f9b\u53ef\u4ee5\u5f53\u4e94\u6052\u7684\u51b7\u70ed\u6e90\u9aa8\u67b6\uff0c\u4f46\u4e24\u8054\u4f9b\u672c\u8eab\u4e0d\u7b49\u4e8e\u4e94\u6052\uff1b\u4e94\u6052\u4e00\u5b9a\u6709\u4e00\u5957\u7edf\u4e00\u667a\u63a7\u53bb\u534f\u8c03\u5404\u4e2a\u7ef4\u5ea6\uff0c\u4e24\u8054\u4f9b\u6ca1\u6709\u8fd9\u4e2a\u8981\u6c42\u3002\u4e70\u4e4b\u524d\u5148\u5206\u6e05\uff1a\u4f60\u8981\u7684\u662f\u300c\u8212\u670d\u7684\u67b6\u6784\u300d\u8fd8\u662f\u300c\u6052\u5b9a\u7684\u6307\u6807\u300d\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5168\u7a7a\u6c14\u3001\u8f90\u5c04\u3001\u590d\u5408\u5f0f\u7cfb\u7edf\uff0c\u54ea\u79cd\u66f4\u9002\u5408\u5bb6\u5ead\uff1f<\/summary>\n<p>\u7b54\uff1a\u6ca1\u6709\u7edd\u5bf9\u597d\u574f\uff0c\u770b\u6237\u578b\u548c\u9884\u7b97\u3002\u5168\u7a7a\u6c14\u2014\u2014\u4e00\u53f0\u4e3b\u673a\u5904\u7406\u6240\u6709\u7a7a\u6c14\uff0c\u85cf\u5728\u8bbe\u5907\u95f4\uff0c\u9002\u5408\u522b\u5885\u3001\u5c42\u9ad8\u591f\u3001\u60f3\u628a\u6240\u6709\u8bbe\u5907\u96c6\u4e2d\u7ba1\u7406\u7684\uff1b\u8f90\u5c04\u7cfb\u7edf\u2014\u2014\u5730\u6696\uff0f\u9876\u68da\u8f90\u5c04\u7ba1\u8c03\u6e29\uff0c\u5b89\u9759\u65e0\u98ce\u611f\uff0c\u9002\u5408\u5bf9\u98ce\u654f\u611f\u7684\u4eba\uff0c\u4f46\u54cd\u5e94\u6162\u3001\u8981\u63d0\u524d\u8c03\uff1b\u590d\u5408\u5f0f\u2014\u2014\u8f90\u5c04\u6253\u5e95\uff0b\u4f4e\u901f\u98ce\u8f85\u52a9\uff0b\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff0c\u662f\u5bb6\u5ead\u4e94\u6052\u6700\u4e3b\u6d41\u7684\u914d\u6cd5\uff0c\u5e73\u5c42\u5927\u5e73\u5c42\u9996\u9009\u3002\u9f99\u8109\u4e3b\u63a8\u7684\u5c31\u662f\u590d\u5408\u5f0f\uff0c\u5e73\u8861\u4e86\u4f53\u611f\u3001\u6210\u672c\u548c\u53ef\u7ef4\u62a4\u6027\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7684\u300c\u6052\u9759\u300d\u9760\u4ec0\u4e48\u5b9e\u73b0\uff1f\u98ce\u53e3\u566a\u97f3\u600e\u4e48\u538b\u4e0b\u6765\uff1f<\/summary>\n<p>\u7b54\uff1a\u9760\u4e09\u6837\uff1a\u4e00\u662f\u4f4e\u901f\u98ce\uff0c\u9001\u98ce\u53e3\u98ce\u901f\u538b\u5230\u5f88\u4f4e\uff0c\u4eba\u57fa\u672c\u611f\u89c9\u4e0d\u5230\u98ce\uff1b\u4e8c\u662f\u8f90\u5c04\u672b\u7aef\u6253\u5e95\uff0c\u5927\u90e8\u5206\u51b7\u70ed\u9760\u8f90\u5c04\u4f20\u9012\uff0c\u4e0d\u7528\u9760\u5927\u98ce\u91cf\u786c\u5439\uff1b\u4e09\u662f\u6d88\u97f3\u98ce\u7ba1\u548c\u597d\u7684\u98ce\u53e3\u9009\u578b\uff0c\u628a\u4e3b\u673a\u548c\u98ce\u9053\u7684\u566a\u97f3\u5728\u8def\u4e0a\u5c31\u5403\u6389\u3002\u884c\u4e1a\u4e00\u822c\u8981\u6c42\u98ce\u53e3\u566a\u97f3\u4e0d\u8d85\u8fc7 25 \u5206\u8d1d\uff08\u6bd4\u56fe\u4e66\u9986\u7ffb\u4e66\u8fd8\u8f7b\uff09\u3002\u5982\u679c\u67d0\u5bb6\u4e94\u6052\u300c\u5435\u300d\uff0c\u591a\u534a\u662f\u98ce\u7ba1\u98ce\u901f\u6ca1\u7b97\u597d\u6216\u98ce\u53e3\u9009\u578b\u9519\uff0c\u4e0d\u662f\u7cfb\u7edf\u672c\u8eab\u7684\u95ee\u9898\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u8f90\u5c04\u672b\u7aef\u662f\u4ec0\u4e48\uff1f\u9876\u9762\u8f90\u5c04\u548c\u5730\u9762\u8f90\u5c04\u600e\u4e48\u9009\uff1f<\/summary>\n<p>\u7b54\uff1a\u8f90\u5c04\u672b\u7aef\u5c31\u662f\u57cb\u5728\u9876\u9762\u6216\u5730\u9762\u7684\u76d8\u7ba1\uff0c\u9760\u8868\u9762\u6e29\u5ea6\u300c\u6084\u6084\u300d\u628a\u70ed\u91cf\u8f90\u5c04\u7ed9\u623f\u95f4\uff0c\u4e0d\u50cf\u7a7a\u8c03\u9760\u5439\u98ce\u3002\u5730\u9762\u8f90\u5c04\u6700\u6210\u719f\u3001\u811a\u5e95\u6696\u3001\u6700\u5e38\u7528\uff0c\u51e0\u4e4e\u6240\u6709\u4e94\u6052\u90fd\u505a\u5730\u9762\u8f90\u5c04\u5730\u6696\uff1b\u9876\u9762\u8f90\u5c04\u9002\u5408\u5c42\u9ad8\u591f\u7684\u522b\u5885\uff0c\u5347\u6e29\u6bd4\u5730\u9762\u5feb\u3001\u4e0d\u5360\u5730\u9762\u3001\u53ef\u4ee5\u548c\u540a\u9876\u4e00\u8d77\u505a\uff0c\u4f46\u9020\u4ef7\u9ad8\u3002\u4e00\u822c\u5bb6\u5ead\u5730\u9762\u8f90\u5c04\u4e3a\u4e3b\u5c31\u591f\u4e86\uff1b\u9876\u9762\u8f90\u5c04\u662f\u300c\u52a0\u9879\u300d\uff0c\u5c42\u9ad8\u548c\u9884\u7b97\u90fd\u591f\u518d\u8003\u8651\uff0c\u4e0d\u662f\u5fc5\u9009\u9879\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7ed3\u9732\u98ce\u9669\u600e\u4e48\u7834\uff1f\u6210\u90fd\u6885\u96e8\u5b63\u600e\u4e48\u529e\uff1f<\/summary>\n<p>\u7b54\uff1a\u7ed3\u9732\u7684\u672c\u8d28\u662f\u300c\u51b7\u8868\u9762\u78b0\u5230\u9ad8\u6e7f\u7a7a\u6c14\u300d\u3002\u4e94\u6052\u9760\u4e09\u9053\u5173\u9632\uff1a\u4e00\u662f\u9732\u70b9\u6e29\u63a7\uff0c\u5b9e\u65f6\u7b97\u5f53\u524d\u7a7a\u6c14\u9732\u70b9\uff0c\u6c34\u6e29\u4f4e\u4e8e\u9732\u70b9\u5c31\u81ea\u52a8\u8c03\u9ad8\uff0c\u4e0d\u8ba9\u8f90\u5c04\u9762\u51b7\u5230\u7ed3\u73e0\uff1b\u4e8c\u662f\u9664\u6e7f\u4f18\u5148\uff0c\u6885\u96e8\u5b63\u65b0\u98ce\u9664\u6e7f\u5168\u5f00\uff0c\u5148\u628a\u9001\u98ce\u542b\u6e7f\u91cf\u538b\u5230 8 \u514b\u6bcf\u5343\u514b\u4ee5\u4e0b\u518d\u9001\uff1b\u4e09\u662f\u5730\u9762\u4fdd\u6e29\u505a\u8db3\uff0c\u8f90\u5c04\u7ba1\u4e0b\u9762\u4fdd\u6e29\u5c42\u591f\u539a\u3002\u6210\u90fd\u6885\u96e8\u5b63\u5ba4\u5916\u542b\u6e7f\u91cf\u80fd\u5230 18-20 \u514b\u6bcf\u5343\u514b\uff0c\u6240\u4ee5\u8fd9\u5957\u9664\u6e7f\u65b0\u98ce\u5728\u6210\u90fd\u662f\u300c\u5fc5\u9009\u9879\u300d\u4e0d\u662f\u300c\u53ef\u9009\u9879\u300d\uff0c\u65b9\u6848\u9636\u6bb5\u5c31\u5f97\u6309\u5f53\u5730\u6c14\u5019\u9009\u578b\uff0c\u4e0d\u80fd\u5957\u5317\u65b9\u6a21\u677f\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7684\u63a7\u5236\u5c42\u4e3a\u4ec0\u4e48\u5173\u952e\uff1f\u6ca1\u6709\u5b83\u4f1a\u600e\u6837\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e94\u6052\u7684\u51e0\u4e2a\u7ef4\u5ea6\uff08\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001\u65b0\u98ce\u3001\u6d01\u51c0\uff09\u5fc5\u987b\u7531\u4e00\u4e2a\u5e73\u53f0\u540c\u65f6\u8c03\u5ea6\uff0c\u5426\u5219\u5c31\u9000\u56de\u300c\u5404\u5e72\u5404\u7684\u300d\u3002\u6bd4\u5982\u6e7f\u5ea6\u9ad8\u4e86\uff0c\u65b0\u98ce\u8981\u4e0d\u8981\u52a0\u5927\u3001\u5730\u6696\u6c34\u6e29\u8981\u4e0d\u8981\u964d\uff0c\u8fd9\u4e24\u4ef6\u4e8b\u5f97\u6709\u4eba\u534f\u8c03\uff1b\u6ca1\u6709\u7edf\u4e00\u667a\u63a7\uff0c\u6e7f\u5ea6\u6a21\u5757\u548c\u5730\u6696\u6a21\u5757\u5404\u7ba1\u5404\u7684\uff0c\u7ed3\u679c\u5c31\u662f\u8981\u4e48\u6f6e\u3001\u8981\u4e48\u5e72\u3001\u8981\u4e48\u80fd\u8017\u7206\u8868\u3002\u6240\u4ee5\u63a7\u5236\u5c42\u662f\u4e94\u6052\u7684\u300c\u5927\u8111\u300d\uff0c\u8bbe\u5907\u9f50\u4e0d\u7b49\u4e8e\u7cfb\u7edf\u6210\u7acb\u2014\u2014\u8fd9\u4e5f\u662f\u4e3a\u4ec0\u4e48\u53ea\u88c5\u8f90\u5c04\u5730\u6696\uff0b\u666e\u901a\u65b0\u98ce\u4e0d\u7b97\u4e94\u6052\u3002\u9f99\u8109\u7528\u65e5\u7acb\u5168\u5c4b\u5168\u611f 3.0 \u505a\u8fd9\u5c42\u8c03\u5ea6\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u65e5\u7acb\u5168\u5c4b\u5168\u611f 3.0 \u662f\u4ec0\u4e48\uff1f\u548c\u4e94\u6052\u4ec0\u4e48\u5173\u7cfb\uff1f<\/summary>\n<p>\u7b54\uff1a\u5168\u5c4b\u5168\u611f 3.0 \u662f\u65e5\u7acb\u7684\u4e00\u5957\u5168\u5c4b\u73af\u5883\u96c6\u6210\u63a7\u5236\u7cfb\u7edf\uff0c\u4e5f\u662f\u9f99\u8109\u4e3b\u63a8\u4e94\u6052\u65b9\u6848\u7684\u300c\u5927\u8111\u300d\u3002\u5b83\u628a\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u52a0\u6e7f\u3001\u8fc7\u6ee4\u8fd9\u4e9b\u5b50\u7cfb\u7edf\u63a5\u5230\u4e00\u4e2a\u5e73\u53f0\u4e0a\uff0c\u6309\u5ba4\u5185\u6e29\u6e7f\u6c27\u6d01\u9759\u4e94\u4e2a\u7ef4\u5ea6\u7edf\u4e00\u8c03\u5ea6\uff0c\u8fd8\u80fd\u624b\u673a\u4e0a\u770b\u5b9e\u65f6\u6570\u636e\u548c\u8fdc\u7a0b\u8c03\u8282\u3002\u7b80\u5355\u8bf4\uff1a\u4e94\u6052\u662f\u76ee\u6807\uff0c\u5168\u5c4b\u5168\u611f 3.0 \u662f\u5b9e\u73b0\u8fd9\u4e2a\u76ee\u6807\u7684\u63a7\u5236\u7cfb\u7edf\u3002\u9009\u578b\u65f6\u8bbe\u5907\u548c\u667a\u63a7\u8981\u4e00\u8d77\u5b9a\uff0c\u522b\u53ea\u6bd4\u4e3b\u673a\u4ef7\u683c\u6f0f\u4e86\u8fd9\u5c42\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u7cfb\u7edf\u4e3b\u673a\u548c\u672b\u7aef\u600e\u4e48\u914d\uff1f<\/summary>\n<p>\u7b54\uff1a\u4e94\u6052\u662f\u300c\u4e09\u8054\u300d\u7ed3\u6784\uff1a\u51b7\u70ed\u6e90\uff08\u7a7a\u6c14\u6e90\u70ed\u6cf5\u6216\u5168\u7a7a\u6c14\u4e3b\u673a\uff09\uff0b\u7a7a\u6c14\u5904\u7406\uff08\u9664\u6e7f\u65b0\u98ce\u4e3b\u673a\u3001\u52a0\u6e7f\u3001\u8fc7\u6ee4\uff09\uff0b\u672b\u7aef\uff08\u5730\u9762\uff0f\u9876\u9762\u8f90\u5c04\u76d8\u7ba1\uff09\uff0b\u667a\u63a7\u5e73\u53f0\u3002\u914d\u6cd5\u662f\u5148\u6309\u6237\u578b\u7b97\u51b7\u70ed\u8d1f\u8377\u5b9a\u4e3b\u673a\u5927\u5c0f\uff0c\u518d\u6309\u6362\u6c14\u6b21\u6570\uff08\u4e00\u822c 6 \u5230 11 \u6b21\u6bcf\u5c0f\u65f6\uff09\u5b9a\u9664\u6e7f\u65b0\u98ce\u91cf\uff0c\u8f90\u5c04\u672b\u7aef\u9762\u79ef\u8ddf\u7740\u91c7\u6696\u5236\u51b7\u8d1f\u8377\u8d70\uff0c\u6700\u540e\u6240\u6709\u8bbe\u5907\u63a5\u5230\u667a\u63a7\u5e73\u53f0\u7edf\u4e00\u8c03\u5ea6\u3002\u672b\u7aef\u548c\u4e3b\u673a\u4e0d\u662f\u5b64\u7acb\u9009\u7684\uff0c\u8d1f\u8377\u7b97\u9519\u4e00\u6b65\uff0c\u540e\u9762\u5168\u6b6a\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u5e73\u5c42\uff0f\u522b\u5885\u4e94\u6052\u65b9\u6848\u600e\u4e48\u914d\uff1f\u548c\u88c5\u4fee\u600e\u4e48\u914d\u5408\uff1f<\/summary>\n<p>\u7b54\uff1a\u6838\u5fc3\u4e00\u53e5\u8bdd\u2014\u2014\u6c34\u7535\u4ea4\u5e95\u4e4b\u524d\u5c31\u628a\u4e94\u6052\u65b9\u6848\u5b9a\u4e86\u3002\u5e73\u5c42\uff1a\u5730\u9762\u8f90\u5c04\u5730\u6696\u6253\u5e95\uff0b\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff0b\u5206\u533a\u63a7\u5236\uff0c\u968f\u88c5\u4fee\u6c34\u7535\u548c\u5730\u6696\u4e00\u8d77\u8d70\uff1b\u522b\u5885\uff1a\u5c42\u9ad8\u591f\u53ef\u4ee5\u52a0\u9876\u9762\u8f90\u5c04\uff0c\u8bbe\u5907\u95f4\u8981\u9884\u7559\u4e3b\u673a\u548c\u9664\u6e7f\u65b0\u98ce\u7684\u4f4d\u5b50\uff0c\u98ce\u7ba1\u8d70\u540a\u9876\u3002\u6700\u6015\u7684\u662f\u88c5\u4fee\u90fd\u5feb\u5b8c\u4e86\u624d\u60f3\u8d77\u6765\u52a0\u4e94\u6052\uff0c\u90a3\u65f6\u5019\u9690\u853d\u5de5\u7a0b\u6ca1\u7559\u4f4d\uff0c\u53ea\u80fd\u5c06\u5c31\u6216\u8005\u91cd\u505a\u3002\u6240\u4ee5\u4e94\u6052\u548c\u88c5\u4fee\u662f\u300c\u540c\u6b65\u8bbe\u8ba1\u300d\uff0c\u4e0d\u662f\u300c\u540e\u52a0\u300d\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4ec0\u4e48\u5bb6\u5ead\u8be5\u4e0a\u4e94\u6052\uff1f\u8c01\u4e0d\u9002\u5408\u505a\u4e94\u6052\uff1f<\/summary>\n<p>\u7b54\uff1a\u9002\u5408\uff1a\u5bf9\u8212\u9002\u5ea6\u654f\u611f\uff08\u6015\u98ce\u3001\u6015\u5e72\u3001\u6015\u5435\uff09\u3001\u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\u6216\u8fc7\u654f\u4eba\u7fa4\u3001\u9884\u7b97\u591f\u3001\u6253\u7b97\u957f\u4f4f\u3002\u4e0d\u9002\u5408\uff1a\u51fa\u79df\u623f\u6216\u77ed\u671f\u6301\u6709\uff08\u6295\u5165\u644a\u4e0d\u56de\u6765\uff09\u3001\u88c5\u4fee\u5df2\u7ecf\u5b9a\u578b\u6ca1\u6cd5\u52a8\u9690\u853d\u5de5\u7a0b\uff08\u53ea\u80fd\u5c40\u90e8\u6539\u5584\uff09\u3001\u9884\u7b97\u7d27\u53c8\u53ea\u60f3\u8981\u57fa\u7840\u51b7\u6696\uff08\u4e24\u8054\u4f9b\u66f4\u5212\u7b97\uff09\u3002\u4e94\u6052\u662f\u300c\u4f53\u9a8c\u5347\u7ea7\u300d\u4e0d\u662f\u300c\u521a\u9700\u66ff\u4ee3\u300d\uff0c\u5148\u60f3\u6e05\u695a\u81ea\u5df1\u662f\u4e0d\u662f\u90a3\u7c7b\u5bf9\u4f53\u611f\u6311\u5254\u3001\u4e14\u4f4f\u5f97\u4e45\u7684\u4eba\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u6bd4\u666e\u901a\u4e24\u8054\u4f9b\u8d35\u591a\u5c11\uff1f\u591a\u82b1\u7684\u94b1\u503c\u4e0d\u503c\uff1f<\/summary>\n<p>\u7b54\uff1a\u8d35\u5728\u300c\u7a7a\u6c14\u5904\u7406\u300d\u548c\u300c\u63a7\u5236\u300d\u4e24\u5757\u3002\u666e\u901a\u4e24\u8054\u4f9b\u7ba1\u51b7\u6696\uff0c\u4e94\u6052\u591a\u4e86\u9664\u6e7f\u65b0\u98ce\u3001\u52a0\u6e7f\u3001\u8fc7\u6ee4\u548c\u4e00\u5957\u667a\u63a7\u5e73\u53f0\uff0c\u8fd9\u90e8\u5206\u56fa\u5b9a\u6210\u672c\u4e3a\u4e3b\u3001\u8ddf\u9762\u79ef\u5173\u7cfb\u4e0d\u5927\uff0c\u6240\u4ee5\u5c0f\u9762\u79ef\u644a\u5f97\u8d35\u3001\u5927\u9762\u79ef\u76f8\u5bf9\u5212\u7b97\u3002\u591a\u82b1\u7684\u94b1\u503c\u4e0d\u503c\uff0c\u770b\u4f60\u5728\u4e0d\u5728\u610f\uff1a\u6e7f\u5ea6\u7a33\u5b9a\u4e0d\u95f7\u3001\u7a7a\u6c14\u5e72\u51c0\u4e0d\u8fc7\u654f\u3001\u98ce\u53e3\u6ca1\u566a\u97f3\u3001\u5e38\u5e74\u4f53\u611f\u4e00\u81f4\u3002\u5728\u610f\u8fd9\u4e9b\uff0c\u503c\uff1b\u53ea\u5728\u610f\u300c\u51b7\u4e86\u70ed\u4e86\u300d\uff0c\u4e24\u8054\u4f9b\u5c31\u591f\u4e86\u3002<\/p>\n<\/details>\n<details class=\"lm-faq\">\n<summary>\u95ee\uff1a\u4e94\u6052\u667a\u63a7\u7cfb\u7edf\u6545\u969c\u4e86\u600e\u4e48\u529e\uff1f<\/summary>\n<p>\u7b54\uff1a\u5148\u522b\u614c\uff0c\u591a\u6570\u95ee\u9898\u51fa\u5728\u300c\u8f6f\u4ef6\u5c42\u300d\u800c\u4e0d\u662f\u8bbe\u5907\u574f\u3002\u7b2c\u4e00\u6b65\u67e5\u7f51\u5173\u548c\u4f20\u611f\u5668\u2014\u2014\u5bb6\u91cc Wi-Fi\u3001\u667a\u63a7\u7f51\u5173\u6389\u7ebf\u3001\u67d0\u4e2a\u6e29\u6e7f\u5ea6\u4f20\u611f\u5668\u6ca1\u7535\uff0c\u662f\u6700\u5e38\u89c1\u7684\u539f\u56e0\uff1b\u7b2c\u4e8c\u6b65\u770b\u5e73\u53f0\u80fd\u4e0d\u80fd\u8fdc\u7a0b\u8bca\u65ad\uff0c\u9f99\u8109\u7684\u5168\u5c4b\u5168\u611f 3.0 \u5927\u90e8\u5206\u5f02\u5e38\u80fd\u5728\u540e\u53f0\u770b\u5230\u3001\u8fdc\u7a0b\u590d\u4f4d\uff1b\u7b2c\u4e09\u6b65\u624d\u662f\u6d3e\u5e08\u5085\u4e0a\u95e8\uff0c\u4e00\u822c\u4e5f\u5c31\u662f\u91cd\u542f\u6a21\u5757\u3001\u6362\u4f20\u611f\u5668\u8fd9\u7c7b\u5c0f\u4e8b\u3002\u6240\u4ee5\u9009\u4e94\u6052\u65f6\u300c\u6709\u6ca1\u6709\u8fdc\u7a0b\u8bca\u65ad\u548c\u552e\u540e\u5e73\u53f0\u300d\u6bd4\u300c\u4e3b\u673a\u54c1\u724c\u300d\u66f4\u5f71\u54cd\u4f60\u7701\u4e0d\u7701\u5fc3\u3002<\/p>\n<\/details>\n<h2 class=\"wp-block-heading\">\u5ef6\u4f38\u9605\u8bfb<\/h2>\n<h3 class=\"wp-block-heading\">\u672c\u7cfb\u5217\u5176\u4ed6\u4e09\u518c<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=667\">\u300a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a>\u2014\u2014\u4e3b\u673a\u4e0e\u4e09\u7ba1\u5236\u7684\u672c\u4f53\u77e5\u8bc6<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=669\">\u300a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a>\u2014\u2014\u5730\u6696\u672b\u7aef\u4e0e\u6c34\u529b\u5e73\u8861\u7684\u5b8c\u6574\u505a\u6cd5<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u300a\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/a>\u2014\u2014\u5929\u6c1f\u5730\u6c34\u4e0e\u5929\u6c34\u5730\u6c34\u56db\u6761\u8def\u600e\u4e48\u9009<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u7cfb\u7edf\u4e0e\u673a\u578b<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u8be6\u60c5\u9875<\/a>\u2014\u2014\u56db\u79cd\u914d\u6cd5\u7684\u673a\u578b\u3001\u63a5\u7ba1\u4e0e\u914d\u7f6e<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<\/a>\u2014\u2014\u5929\u6c34\u5730\u6c34\u7684\u7cfb\u7edf\u67b6\u6784\u4e0e\u9009\u578b<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u4e2d\u592e\u7a7a\u8c03\u6280\u672f\u767d\u76ae\u4e66<\/a>\u2014\u2014\u6c1f\u7cfb\u7edf\u9009\u578b\u4e0e\u5b89\u88c5\u7684\u5b8c\u6574\u8bfb\u672c<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13292\">\u4e94\u6052\u7cfb\u7edf \u00b7 \u54c1\u7c7b\u603b\u89c8<\/a>\u2014\u2014\u4ece\u54c1\u7c7b\u89d2\u5ea6\u770b\u4e94\u6052\u80fd\u89e3\u51b3\u4ec0\u4e48<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u672b\u7aef\u4e0e\u914d\u5957<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=1976\">\u5730\u6696\u7cfb\u7edf<\/a>\u2014\u2014\u76d8\u7ba1\u95f4\u8ddd\u3001\u4e3b\u7ba1\u7ba1\u5f84\u3001\u5206\u96c6\u6c34\u5668<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=2137\">\u6696\u6c14\u7247\u7cfb\u7edf<\/a>\u2014\u2014\u5df2\u88c5\u4fee\u623f\u5b50\u7684\u91c7\u6696\u8def\u5f84<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=1758\">\u65b0\u98ce\u7cfb\u7edf<\/a>\u2014\u2014\u6362\u6c14\u91cf\u4e0e\u8fc7\u6ee4\u7b49\u7ea7\u600e\u4e48\u5b9a<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=1849\">\u51c0\u6c34\u7cfb\u7edf<\/a>\u2014\u2014\u5168\u5c4b\u7528\u6c34\u4e0e\u4e94\u6052\u7684\u914d\u5408<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6848\u4f8b<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u6210\u90fd\u4e94\u6052\u4e0e\u4e24\u8054\u4f9b\u6df1\u5ea6\u6848\u4f8b<\/a>\u2014\u2014\u5e26\u65bd\u5de5\u8fc7\u7a0b\u4e0e\u5b9e\u6d4b\u6570\u636e\u7684\u5b8c\u6574\u8bb0\u5f55<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">\u9644\u5f55<\/h2>\n<h3 class=\"wp-block-heading\">A. \u672f\u8bed\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u672f\u8bed<\/strong><\/td>\n<td><strong>\u89e3\u91ca<\/strong><\/td>\n<\/tr>\n<tr>\n<td>AHU<\/td>\n<td>\u7a7a\u6c14\u5904\u7406\u673a\u7ec4<\/td>\n<\/tr>\n<tr>\n<td>THIC<\/td>\n<td>\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236<\/td>\n<\/tr>\n<tr>\n<td>CFD<\/td>\n<td>\u8ba1\u7b97\u6d41\u4f53\u52a8\u529b\u5b66<\/td>\n<\/tr>\n<tr>\n<td>DOAS<\/td>\n<td>\u72ec\u7acb\u65b0\u98ce\u5168\u7a7a\u6c14\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u5168\u5c4b\u5168\u611f<\/td>\n<td>\u65e5\u7acb\u4e94\u6052\u7cfb\u7edf\u96c6\u6210\u5e73\u53f0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">B. \u4e94\u6052\u7cfb\u7edf\u8bbe\u8ba1\u53c2\u6570\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u53c2\u6570<\/strong><\/td>\n<td><strong>\u63a8\u8350\u503c<\/strong><\/td>\n<td><strong>\u4f9d\u636e<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u5ea6\uff08\u590f\/\u51ac\uff09<\/td>\n<td>24-26\u2103\/20-22\u2103<\/td>\n<td>GB 50736<\/td>\n<\/tr>\n<tr>\n<td>\u6e7f\u5ea6<\/td>\n<td>40%-60%<\/td>\n<td>GB\/T 18883<\/td>\n<\/tr>\n<tr>\n<td>CO\u2082<\/td>\n<td>\u2264800ppm<\/td>\n<td>\u5065\u5eb7\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>PM2.5<\/td>\n<td>\u226425\u03bcg\/m\u00b3<\/td>\n<td>T\/CECS 1800<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u6c14\u6b21\u6570<\/td>\n<td>6-11\u6b21\/h<\/td>\n<td>\u4e94\u6052\u6807\u51c6<\/td>\n<\/tr>\n<tr>\n<td>\u65e5\u7acb\u5185\u673a\u6700\u4f4e\u566a\u97f3<\/td>\n<td>17dB<\/td>\n<td>\u5b98\u65b9\u6570\u636e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">C. \u5168\u5c4b\u5168\u611f\u667a\u80fd\u6a21\u5f0f\u53c2\u6570\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u53c2\u6570<\/strong><\/td>\n<td><strong>\u667a\u80fd\u6a21\u5f0f<\/strong><\/td>\n<td><strong>\u5f3a\u5236\u5236\u51b7\u6a21\u5f0f<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u51fa\u98ce\u53e3\u6e29\u5ea6<\/td>\n<td>\u7ea624\u2103<\/td>\n<td>\u7ea610\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u4f53\u611f<\/td>\n<td>\u51c9\u800c\u4e0d\u51b7<\/td>\n<td>\u51b7\u98ce\u76f4\u5439<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">D. \u9664\u6e7f\u80fd\u529b\u8fb9\u754c\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u7cfb\u7edf\u7c7b\u578b<\/strong><\/td>\n<td><strong>\u8fd0\u884c\u72b6\u6001<\/strong><\/td>\n<td><strong>\u9664\u6e7f\u80fd\u529b<\/strong><\/td>\n<td><strong>\u89e3\u51b3\u65b9\u6848<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u6c1f\u5730\u6c34<\/td>\n<td>\u9ad8\u6c1f\u6e29\u8fd0\u884c<\/td>\n<td>\u26a0\ufe0f \u53d7\u9650<\/td>\n<td>\u9664\u6e7f\u65b0\u98ce\u72ec\u7acb\u9664\u6e7f<\/td>\n<\/tr>\n<tr>\n<td>\u5929\u6c34\u5730\u6c34<\/td>\n<td>\u9ad8\u6c34\u6e29\u8fd0\u884c<\/td>\n<td>\u26a0\ufe0f \u53d7\u9650<\/td>\n<td>\u9664\u6e7f\u65b0\u98ce\u72ec\u7acb\u9664\u6e7f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">E. \u5e38\u89c1\u95ee\u9898\u901f\u67e5<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95ee\u9898<\/strong><\/td>\n<td><strong>\u539f\u56e0<\/strong><\/td>\n<td><strong>\u89e3\u51b3\u65b9\u6848<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u677f\u7ed3\u9732<\/td>\n<td>\u65b0\u98ce\u9664\u6e7f\u4e0d\u8db3<\/td>\n<td>\u589e\u5f3a\u9664\u6e7f\u3001\u8c03\u9ad8\u6c34\u6e29<\/td>\n<\/tr>\n<tr>\n<td>\u51ac\u5b63\u5e72\u71e5<\/td>\n<td>\u65e0\u52a0\u6e7f\u529f\u80fd<\/td>\n<td>\u914d\u7f6e\u52a0\u6e7f\u6a21\u5757<\/td>\n<\/tr>\n<tr>\n<td>\u80fd\u8017\u8fc7\u9ad8<\/td>\n<td>\u7cfb\u7edf\u5339\u914d\u4e0d\u5f53<\/td>\n<td>\u5168\u53d8\u9891+\u70ed\u56de\u6536+\u5206\u533a\u63a7\u5236<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">F. \u4ea4\u53c9\u5f15\u7528\u7d22\u5f15<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u4e3b\u9898<\/strong><\/td>\n<td><strong>\u672c\u518c\u4f4d\u7f6e<\/strong><\/td>\n<td><strong>\u8de8\u518c\u53c2\u89c1<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u7684\u5b9a\u4e49\u4e0e\u884c\u4e1a\u6807\u51c6<\/td>\n<td>1.1 \/ 1.4 \/ 1.5<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e29\uff1a\u6e29\u5ea6\u6ce2\u52a8\u7684\u63a7\u5236<\/td>\n<td>2.1<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e7f\uff1a\u542b\u6e7f\u91cf\u4e0e\u9732\u70b9<\/td>\n<td>2.2<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6c27\uff1aCO\u2082 \u6d53\u5ea6\u4e0e\u65b0\u98ce\u91cf<\/td>\n<td>2.3<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6d01\uff1a\u8fc7\u6ee4\u4e0e\u6740\u83cc<\/td>\n<td>2.4<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u9759\uff1a\u4e09\u91cd\u964d\u566a<\/td>\n<td>2.5<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u5168\u7a7a\u6c14 \/ \u8f90\u5c04 \/ \u590d\u5408\u5f0f\u600e\u4e48\u9009<\/td>\n<td>3.1 \/ 3.2 + 8.2<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u4f9b\u51b7\u4e0e\u9632\u7ed3\u9732<\/td>\n<td>3.3 \/ 3.4 + 9.4<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\uff08THIC\uff09<\/td>\n<td>4.6<\/td>\n<td>01 \u53f7\u624b\u518c \u00b7 \u4e09\u7ba1\u5236\u90e8\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u4ea7\u54c1\u914d\u7f6e\u901f\u67e5<\/td>\n<td>5.4<\/td>\n<td>1957 \u5929\u6c1f\u5730\u6c34 \/ 13098 \u5929\u6c34\u5730\u6c34<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u53c2\u6570\u4e0e\u65b0\u98ce\u89c4\u8303<\/td>\n<td>6.2 \/ 6.3<\/td>\n<td>02 \u53f7\u624b\u518c \u00b7 \u5730\u6696\u505a\u6cd5<\/td>\n<\/tr>\n<tr>\n<td>\u65bd\u5de5\u9a8c\u6536\u4e0e\u68c0\u4fee\u53e3<\/td>\n<td>6.4<\/td>\n<td>02 \u53f7\u624b\u518c<\/td>\n<\/tr>\n<tr>\n<td>\u4e94\u6052\u4e0e\u4e24\u8054\u4f9b\u7684\u5206\u754c<\/td>\n<td>8.1<\/td>\n<td>03 \u53f7\u624b\u518c \u00b7 \u7b2c\u4e8c\u90e8\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d<\/td>\n<td>5.4<\/td>\n<td>03 \u53f7\u624b\u518c \u00b7 \u7b2c\u56db\u90e8\u5206<\/td>\n<\/tr>\n<tr>\n<td>\u7ef4\u4fdd\u4e0e\u552e\u540e<\/td>\n<td>9.1 \u81f3 9.3<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c\u4fe1\u606f<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>\u7248\u672c\uff1aV2.3<\/li>\n<li>\u7f16\u5236\uff1a\u9f99\u8109\u6696\u901a \u00b7 IMA\u77e5\u8bc6\u5e93<\/li>\n<li>\u65e5\u671f\uff1a2026\u5e7410\u670824\u65e5<\/li>\n<li>\u6027\u8d28\uff1a\u957f\u671f\u5b58\u6863\u77e5\u8bc6\u5e93<\/li>\n<li>\u7cfb\u5217\u5e8f\u53f7\uff1a04<\/li>\n<\/ul>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n<h2 class=\"wp-block-heading\">\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p class=\"wp-block-paragraph\">\u4e94\u6052\u7cfb\u7edf\u7ba1\u7684\u662f\u4e00\u6574\u5e74\u7684\u6e29\u5ea6\u3001\u6e7f\u5ea6\u548c\u7a7a\u6c14\uff0c\u623f\u5b50\u671d\u5411\u3001\u5c42\u9ad8\u3001\u5e38\u4f4f\u4eba\u6570\u4e0d\u540c\uff0c\u505a\u6cd5\u5c31\u4e0d\u4e00\u6837\u3002\u624b\u518c\u91cc\u5bf9\u4e0a\u4e86\u4f60\u5bb6\u7684\u60c5\u51b5\uff0c\u53ef\u4ee5\u76f4\u63a5\u627e\u6211\u4eec\u804a\uff1b\u6210\u90fd\u4e3b\u57ce\u53ca\u5468\u8fb9\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u770b\u5b8c\u73b0\u573a\u518d\u8c08\u65b9\u6848\u3002<\/p>\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>\u95e8\u5e97<\/strong><\/td>\n<td><strong>\u5730\u5740<\/strong><\/td>\n<td><strong>\u7535\u8bdd<\/strong><\/td>\n<td><strong>\u5bfc\u822a<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/td>\n<td>\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B \/ A348<\/td>\n<td><a href=\"tel:02886131795\">028-86131795<\/a><\/td>\n<td><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/td>\n<td>\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<\/td>\n<td><a href=\"tel:02865272586\">028-65272586<\/a><\/td>\n<td><a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"wp-block-paragraph\">\u4e24\u5bb6\u95e8\u5e97\u90fd\u5728\u6210\u90fd\u5bcc\u68ee\u7f8e\u5bb6\u5c45\uff0c\u53ef\u4ee5\u76f4\u63a5\u5230\u5e97\u770b\u5b9e\u7269\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u8425\u4e1a\u65f6\u95f4<\/strong>\uff1a\u5468\u4e00\u5230\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u5468\u65e5 10:00\u201319:00\u3002<\/p>\n<p class=\"wp-block-paragraph\"><strong>\u9500\u552e\u987e\u95ee<\/strong>\uff1a\u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a>\uff1b\u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a>\u3002<\/p>\n<section style=\"margin:28px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #c25a1f;border-radius:10px;background:#fffaf6;\">\n<p style=\"margin:0;font-size:15px;line-height:1.8;color:#1a1a1a;\">\u521a\u63a5\u89e6\u4e94\u6052\u3001\u8fd8\u6ca1\u51b3\u5b9a\u8981\u4e0d\u8981\u4e0a\uff1f\u5148\u770b <a href=\"https:\/\/longmai-nt.com\/?page_id=20392\" style=\"color:#c25a1f;font-weight:700;text-decoration:none;\">\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u662f\u4ec0\u4e48\u00b7\u4ec0\u4e48\u5bb6\u5ead\u8be5\u4e0a\u4e94\u6052<\/a>\uff0c\u4e00\u7bc7\u8bb2\u6e05\u5b83\u548c\u4e2d\u592e\u7a7a\u8c03\uff0b\u5730\u6696\u5206\u5f00\u88c5\u7684\u5dee\u522b\u3001\u54ea\u4e9b\u5bb6\u5ead\u9002\u5408\u3001\u5c42\u9ad8\u9884\u7b97\u7ef4\u62a4\u8fd9\u4e9b\u95e8\u69db\u600e\u4e48\u7b97\uff0c\u518d\u56de\u5230\u672c\u518c\u770b\u6280\u672f\u7ec6\u8282\u3002<\/p>\n<\/section>\n<section style=\"margin:28px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0;font-size:15px;line-height:1.8;color:#1a1a1a;\">\u60f3\u7cfb\u7edf\u8bfb\u5b8c\u9f99\u8109\u6696\u901a\u7684\u5168\u90e8\u6280\u672f\u5185\u5bb9\uff1f\u56de\u5230 <a href=\"https:\/\/longmai-nt.com\/?page_id=16039\" style=\"color:#c25a1f;font-weight:700;text-decoration:none;\">\u9f99\u8109\u6696\u901a\u767d\u76ae\u4e66\u4e2d\u5fc3<\/a>\uff0c\u96c6\u4e2d\u83b7\u53d6 17 \u672c\u767d\u76ae\u4e66\u4e0e\u56db\u672c\u6280\u672f\u624b\u518c\u3002<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u7248\u672c\uff1aV2.3 \u7f16\u5236\u65e5\u671f\uff1a2026\u5e7410 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-673","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u624b\u518c\uff1a\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\uff0c\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u9632\u7ed3\u9732\u600e\u4e48\u63a7\u3001\u540e\u671f\u600e\u4e48\u7ef4\u4fdd\uff0c\u9002\u7528\u4e8e\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c\u9644\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u7b49\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u5b9e\u9645\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=673\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u624b\u518c\uff1a\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\uff0c\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u9632\u7ed3\u9732\u600e\u4e48\u63a7\u3001\u540e\u671f\u600e\u4e48\u7ef4\u4fdd\uff0c\u9002\u7528\u4e8e\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c\u9644\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u7b49\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u5b9e\u9645\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=673\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T10:21:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673\",\"name\":\"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\",\"datePublished\":\"2026-05-13T09:22:57+00:00\",\"dateModified\":\"2026-11-21T10:21:00+00:00\",\"description\":\"\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u624b\u518c\uff1a\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\uff0c\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u9632\u7ed3\u9732\u600e\u4e48\u63a7\u3001\u540e\u671f\u600e\u4e48\u7ef4\u4fdd\uff0c\u9002\u7528\u4e8e\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c\u9644\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u7b49\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u5b9e\u9645\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\",\"width\":1240,\"height\":1754},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=673#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u624b\u518c\uff1a\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\uff0c\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u9632\u7ed3\u9732\u600e\u4e48\u63a7\u3001\u540e\u671f\u600e\u4e48\u7ef4\u4fdd\uff0c\u9002\u7528\u4e8e\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c\u9644\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u7b49\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u5b9e\u9645\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=673","og_locale":"zh_CN","og_type":"article","og_title":"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u624b\u518c\uff1a\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\uff0c\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u9632\u7ed3\u9732\u600e\u4e48\u63a7\u3001\u540e\u671f\u600e\u4e48\u7ef4\u4fdd\uff0c\u9002\u7528\u4e8e\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c\u9644\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u7b49\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u5b9e\u9645\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=673","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-21T10:21:00+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=673","url":"https:\/\/longmai-nt.com\/?page_id=673","name":"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=673#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=673#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","datePublished":"2026-05-13T09:22:57+00:00","dateModified":"2026-11-21T10:21:00+00:00","description":"\u6210\u90fd\u4e94\u6052\u7cfb\u7edf\u6280\u672f\u624b\u518c\uff1a\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u4e94\u4e2a\u7ef4\u5ea6\u5404\u81ea\u8981\u505a\u5230\u591a\u5c11\u3001\u600e\u4e48\u9a8c\u6536\uff0c\u8f90\u5c04\u4e0e\u5168\u7a7a\u6c14\u4e0e\u590d\u5408\u5f0f\u4e09\u6761\u8def\u7ebf\u600e\u4e48\u9009\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u600e\u4e48\u914d\u3001\u9632\u7ed3\u9732\u600e\u4e48\u63a7\u3001\u540e\u671f\u600e\u4e48\u7ef4\u4fdd\uff0c\u9002\u7528\u4e8e\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c\u9644\u9e93\u6e56\u3001\u5929\u5e9c\u516c\u9986\u7b49\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u5b9e\u9645\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=673#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=673"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=673#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg","width":1240,"height":1754},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=673#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/673","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=673"}],"version-history":[{"count":18,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/673\/revisions"}],"predecessor-version":[{"id":21113,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/673\/revisions\/21113"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=673"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}