{"id":6786,"date":"2026-07-24T21:25:01","date_gmt":"2026-07-24T13:25:01","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=6786"},"modified":"2026-07-24T21:40:22","modified_gmt":"2026-07-24T13:40:22","slug":"%e4%b8%ad%e7%b2%ae%e7%91%9e%e5%ba%9c%e7%8e%ba%e9%99%a2-%c2%b7-%e5%a4%a9%e6%b0%b4%e5%9c%b0%e6%b0%b4%e4%b8%a4%e8%81%94%e4%be%9b%e6%96%b0%e9%a3%8e%e6%a1%a3%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=6786","title":{"rendered":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" style=\"line-height:0.8;text-indent:7px\"><strong>\u6863\u6848\u7f16\u53f7\uff1a<\/strong>zlrfxi-tsds-lls-202607<\/p>\n\n<p class=\"wp-block-paragraph\" style=\"line-height:0.8;text-indent:7px\"><strong>\u5ba2\u6237\uff1a<\/strong>\u5170\u8001\u5e08<\/p>\n\n<p class=\"wp-block-paragraph\" style=\"line-height:0.8;text-indent:7px\"><strong>\u9879\u76ee\u5730\u5740\uff1a<\/strong>\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662<\/p>\n\n<p class=\"wp-block-paragraph\" style=\"line-height:0.8;text-indent:7px\"><strong>\u623f\u5c4b\u9762\u79ef<\/strong>\uff1a200\u33a1+<\/p>\n\n<p class=\"wp-block-paragraph\" style=\"line-height:0.8;text-indent:7px\"><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u9ec4\u52c7  15828489188<\/p>\n\n<p class=\"wp-block-paragraph\" style=\"line-height:0.8;text-indent:7px\"><strong>\u7248\u672c<\/strong>\uff1a\u6863\u6848\u7248 v1.0<\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"font-size:28px\"><strong>\u7b2c\u4e00\u9636\u6bb5\uff1a\u9700\u6c42\u8bca\u65ad\u548c\u5206\u6790<\/strong><\/p>\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5ba2\u6237\u9700\u6c42\u548c\u65b9\u6848\u914d\u7f6e<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n<div aria-labelledby=\"accordion-item-1\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n\n<style>\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{scroll-behavior:smooth;font-size:16px}\nbody{font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#333;line-height:1.8;background:#f5f5f5}\n\n\/* Breadcrumb (sticky) *\/\n.breadcrumb{position:-webkit-sticky;position:sticky;top:0;z-index:100;background:#fff;border-bottom:1px solid #e3e3e3;box-shadow:0 2px 10px rgba(0,0,0,.08);}\n.breadcrumb .inner{max-width:960px;margin:0 auto;padding:11px 16px;display:flex;align-items:center;flex-wrap:wrap;gap:4px 6px;font-size:13px;line-height:1.5;}\n.breadcrumb a{color:#0f3460;text-decoration:none;white-space:nowrap;}\n.breadcrumb a:hover{color:#c83c3c;text-decoration:underline;}\n.breadcrumb .sep{color:#c4c4c4;margin:0 2px;white-space:nowrap;}\n.breadcrumb .cur{color:#555;font-weight:600;white-space:nowrap;}\n\n\/* Header *\/\n.header{position:relative;color:#fff;padding:56px 24px;text-align:center;overflow:hidden;background:#0f3460 url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-06.png') center\/cover no-repeat;}\n.header::before{content:\"\";position:absolute;inset:0;z-index:0;background:linear-gradient(180deg,rgba(8,20,38,.78) 0%,rgba(8,20,38,.42) 50%,rgba(8,20,38,.76) 100%),radial-gradient(ellipse at center top,rgba(0,0,0,.34),transparent 60%),radial-gradient(ellipse at center bottom,rgba(0,0,0,.38),transparent 56%);}\n.header>*{position:relative;z-index:1;}\n.header h1{text-shadow:0 2px 14px rgba(0,0,0,.5);}\n.header .badge{display:inline-block;background:#c83c3c;padding:3px 14px;border-radius:4px;font-size:12px;letter-spacing:1px;margin-bottom:12px}\n.header h1{font-size:24px;margin-bottom:6px}\n.header .meta{font-size:14px;color:#eaf1f8;display:flex;flex-wrap:wrap;justify-content:center;gap:8px 20px;margin-top:10px}\n.header .meta span{color:#d6e1ec}\n\n\/* Container *\/\n.container{max-width:960px;margin:0 auto;padding:0 16px}\n\n\/* Page header info *\/\n.page-info{background:#fff;border-radius:8px;box-shadow:0 1px 6px rgba(0,0,0,.06);padding:18px 24px;margin:20px 0;display:flex;flex-wrap:wrap;gap:10px 30px;font-size:14px}\n.page-info .info-item{display:flex;gap:6px}\n.page-info .info-label{color:#888}\n.page-info .info-value{font-weight:600;color:#1a1a2e}\n\n\/* TOC *\/\n.toc{background:#fff;border-radius:8px;box-shadow:0 1px 6px rgba(0,0,0,.06);padding:18px 24px;margin:16px 0}\n.toc h3{font-size:15px;color:#c83c3c;margin-bottom:8px;border-bottom:2px solid #c83c3c;padding-bottom:6px}\n.toc ol{list-style:none;counter-reset:item;padding-left:0}\n.toc ol li{counter-increment:item;padding:4px 0;font-size:14px;border-bottom:1px dotted #eee}\n.toc ol li:last-child{border-bottom:none}\n.toc ol li::before{content:counter(item) \". \";color:#c83c3c;font-weight:700;margin-right:4px}\n.toc ol li a{color:#555;text-decoration:none}\n.toc ol li a:hover{color:#c83c3c;text-decoration:underline}\n\n\/* Section *\/\n.section{padding:30px 0}\n.section-title{font-size:20px;color:#1a1a2e;margin-bottom:18px;padding-bottom:8px;border-bottom:3px solid #c83c3c;display:flex;align-items:center;gap:8px}\n.section-title .num{display:inline-flex;align-items:center;justify-content:center;background:#c83c3c;color:#fff;width:26px;height:26px;border-radius:50%;font-size:13px;flex-shrink:0}\n.section-title .sub{font-size:13px;color:#888;font-weight:400;margin-left:auto}\n\n\/* Sub title *\/\nh3.sub-title{font-size:16px;color:#1a1a2e;margin:18px 0 10px;padding-left:10px;border-left:3px solid #c83c3c}\nh4.sub-sub{font-size:15px;color:#c83c3c;margin:14px 0 8px;font-weight:600}\n\n\/* Cards grid *\/\n.card-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(280px,1fr));gap:12px;margin:12px 0}\n.card{background:#fff;border-radius:8px;padding:16px 18px;box-shadow:0 1px 4px rgba(0,0,0,.06);border-left:3px solid #c83c3c}\n.card h4{font-size:15px;color:#1a1a2e;margin-bottom:4px}\n.card p{font-size:14px;color:#555;line-height:1.6}\n\n\/* Table *\/\n.table-wrap{overflow-x:auto;margin:12px 0;border-radius:6px;box-shadow:0 1px 4px rgba(0,0,0,.06)}\ntable{width:100%;border-collapse:collapse;font-size:14px;background:#fff}\nthead{background:#1a1a2e;color:#fff}\nth{padding:9px 12px;text-align:left;font-weight:600;font-size:13px}\ntd{padding:9px 12px;border-bottom:1px solid #eee;font-size:13px}\ntr:last-child td{border-bottom:none}\ntr:nth-child(even){background:#fafafa}\n.highlight{background:#fff3e0!important}\n.highlight td{font-weight:600;color:#c83c3c}\n\n\/* Value highlight box *\/\n.value-box{background:#fff;border-radius:8px;padding:16px 20px;box-shadow:0 1px 4px rgba(0,0,0,.06);margin:12px 0;border:1px solid #e8e8e8}\n.value-box table{border:none;box-shadow:none;margin:0}\n\n\/* Tag *\/\n.tag{display:inline-block;background:#f0f0f0;color:#555;padding:2px 10px;border-radius:10px;font-size:12px;margin:2px}\n\n\/* Promise list *\/\n.promise-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(260px,1fr));gap:10px;margin:12px 0}\n.promise-item{background:#fff;border-radius:6px;padding:12px 16px;border:1px solid #eee;display:flex;align-items:flex-start;gap:8px;font-size:14px}\n.promise-item .icon{color:#c83c3c;font-size:18px;flex-shrink:0;line-height:1.4}\n\n\/* Milestone *\/\n.milestone-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(180px,1fr));gap:10px;margin:12px 0}\n.milestone{background:#fff;border-radius:8px;padding:14px;text-align:center;box-shadow:0 1px 4px rgba(0,0,0,.06);border-top:3px solid #c83c3c}\n.milestone .phase{font-size:12px;color:#c83c3c;font-weight:600}\n.milestone .time{font-size:20px;font-weight:700;color:#1a1a2e;margin:4px 0}\n.milestone .desc{font-size:12px;color:#888}\n\n\/* CTA *\/\n.cta-line{text-align:center;background:#1a1a2e;color:#fff;padding:20px;border-radius:8px;margin:20px 0}\n.cta-line p{font-size:14px;color:#ccc;margin-top:4px}\n\n\/* Footer *\/\n.footer{text-align:center;padding:24px 16px;font-size:13px;color:#888;border-top:1px solid #e0e0e0;margin-top:20px}\n\n@media(max-width:767px){body{font-size:14px}.header{padding:44px 16px}.header h1{font-size:18px}.card-grid,.promise-grid{grid-template-columns:1fr}.milestone-grid{grid-template-columns:1fr 1fr}table{font-size:12px;overflow-x:auto;display:block;white-space:nowrap}}\n<\/style>\n\n<!-- ============================================================ -->\n<!-- Header -->\n<!-- ============================================================ -->\n<!-- TODO: \u53d1\u5e03\u65f6\u4e24\u6587\u4ef6\u7f6e\u4e8e\u540c\u76ee\u5f55\uff0c\u6216\u628a\u4e0b\u5217 href \u66ff\u6362\u4e3a\u7ebf\u4e0a\u771f\u5b9e URL -->\n<nav class=\"breadcrumb\" aria-label=\"\u9762\u5305\u5c51\u5bfc\u822a\">\n  <div class=\"inner\">\n    <a href=\"https:\/\/longmai-nt.com\/\">\u9f99\u8109\u6696\u901a<\/a>\n    <span class=\"sep\">\u203a<\/span>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u5ba2\u6237\u6863\u6848<\/a>\n    <span class=\"sep\">\u203a<\/span>\n    <a href=\"gw-zlrfxi-dangan-s2.html\">\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u7b2c\u4e8c\u9636\u6bb5<\/a>\n    <span class=\"sep\">\u203a<\/span>\n    <span class=\"cur\">\u7b2c\u4e00\u9636\u6bb5 \u00b7 \u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/span>\n  <\/div>\n<\/nav>\n\n<header class=\"header\">\n  <div class=\"badge\">\ud83d\udcc1 \u5ba2\u6237\u6863\u6848 \u00b7 \u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/div>\n  <h1>\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce<\/h1>\n  <div class=\"meta\">\n    <span>\ud83c\udfe0 \u5ba2\u6237\uff1a\u5170\u8001\u5e08<\/span>\n    <span>\ud83d\udccd \u4e2d\u7cae\u745e\u5e9c\u73ba\u9662<\/span>\n    <span>\ud83d\udc64 \u987e\u95ee\uff1a\u9ec4\u52c7 \u00b7 13\u5e74<\/span>\n    <span>\ud83d\udcc5 2026\u5e747\u6708<\/span>\n  <\/div>\n<\/header>\n\n<div class=\"container\">\n\n<!-- ============================================================ -->\n<!-- \u9879\u76ee\u4fe1\u606f -->\n<!-- ============================================================ -->\n<div class=\"page-info\">\n  <div class=\"info-item\"><span class=\"info-label\">\u6863\u6848\u7f16\u53f7\uff1a<\/span><span class=\"info-value\">zlrfxi-tsds-lls-202607<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u623f\u5c4b\u7c7b\u578b\uff1a<\/span><span class=\"info-value\">\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u7a7a\u8c03\u9762\u79ef\uff1a<\/span><span class=\"info-value\">187.55\u33a1<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u5730\u6696\u9762\u79ef\uff1a<\/span><span class=\"info-value\">198.55\u33a1<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u7cfb\u7edf\u7c7b\u578b\uff1a<\/span><span class=\"info-value\">\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b + \u65b0\u98ce<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u7248\u672c\uff1a<\/span><span class=\"info-value\">\u6863\u6848\u7248 v1.0<\/span><\/div>\n<\/div>\n\n<!-- ============================================================ -->\n<!-- TOC -->\n<!-- ============================================================ -->\n<nav class=\"toc\">\n  <h3>\ud83d\udcd1 \u7b2c\u4e00\u9636\u6bb5 \u00b7 \u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1 \u76ee\u5f55<\/h3>\n  <ol>\n    <li><a href=\"#s1\">\u9700\u6c42\u7406\u89e3<\/a><\/li>\n    <li><a href=\"#s2\">\u9700\u6c42\u4e0e\u75db\u70b9\u8bca\u65ad<\/a><\/li>\n    <li><a href=\"#s3\">\u8bbe\u8ba1\u7406\u5ff5<\/a><\/li>\n    <li><a href=\"#s4\">\u8bbe\u8ba1\u4f9d\u636e<\/a><\/li>\n    <li><a href=\"#s5\">\u914d\u7f6e\u603b\u89c8<\/a><\/li>\n    <li><a href=\"#s6\">\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u914d\u7f6e<\/a><\/li>\n    <li><a href=\"#s7\">\u5730\u6696\u7cfb\u7edf\u914d\u7f6e<\/a><\/li>\n    <li><a href=\"#s8\">\u65b0\u98ce\u7cfb\u7edf\u914d\u7f6e<\/a><\/li>\n  <\/ol>\n<\/nav>\n\n<!-- ============================================================ -->\n<!-- 1. \u9700\u6c42\u7406\u89e3 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s1\">\n  <h2 class=\"section-title\"><span class=\"num\">1<\/span>\u9700\u6c42\u7406\u89e3<\/h2>\n  <p style=\"font-size:15px;color:#555;margin-bottom:14px;\">\u5170\u8001\u5e08\u7684\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85\uff0c\u4e1a\u4e3b\u5bf9\u5c45\u4f4f\u8212\u9002\u5ea6\u6709\u8f83\u9ad8\u8981\u6c42\uff0c\u7ecf\u521d\u6b65\u6c9f\u901a\uff0c\u6838\u5fc3\u9700\u6c42\u6e05\u6670\u805a\u7126\uff1a<\/p>\n\n  <div class=\"card-grid\">\n    <div class=\"card\">\n      <h4>\ud83c\udfe0 \u9879\u76ee\u6982\u51b5<\/h4>\n      <p>\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85\uff0c\u7a7a\u8c03\u8986\u76d6187.55\u33a1\uff087\u53f0\u5185\u673a\uff09\uff0c\u5730\u6696\u8986\u76d6198.55\u33a1\uff0814\u8def\u76d8\u7ba1\uff09\u3002\u4e00\u697c\u5ba2\u9910\u538565.5\u33a1\u5927\u7a7a\u95f4\u3001\u4e8c\u697c\u4e09\u4e2a\u5367\u5ba4\uff08\u5408\u8ba168.4\u33a1\uff09\u3001\u4e09\u697c\u8336\u5ba446\u33a1\uff0c\u5206\u533a\u660e\u786e\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83c\udfaf \u6838\u5fc3\u8bc9\u6c42<\/h4>\n      <p><strong>\u8282\u80fd<\/strong>\uff08\u964d\u4f4e\u8fd0\u884c\u8d39\u7528\uff09\u2192 <strong>\u7a33\u5b9a<\/strong> \u2192 <strong>\u8212\u9002<\/strong>\uff0c\u4e09\u4e2a\u5173\u952e\u8bcd\u6309\u4f18\u5148\u7ea7\u6392\u5217\u3002\u4e1a\u4e3b\u5bf9\u957f\u671f\u4f7f\u7528\u6210\u672c\u9ad8\u5ea6\u654f\u611f\uff0c\u5e0c\u671b\u4ece\u7cfb\u7edf\u6e90\u5934\u89e3\u51b3\u80fd\u8017\u95ee\u9898\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udd00 \u7cfb\u7edf\u504f\u597d<\/h4>\n      <p>\u660e\u786e\u503e\u5411<strong>&#8220;\u5929\u6c34\u5730\u6c34&#8221;\u4e24\u8054\u4f9b<\/strong>\u65b9\u6848\uff0c\u5b9e\u73b0\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\u5316\u3002\u4f46\u65e5\u7acb\/\u7ea6\u514b\/\u9ea6\u514b\u7ef4\u5c14\u4e09\u5927\u54c1\u724c\u5747\u5728\u8003\u8651\u4e2d\uff0c\u9700\u8981\u4e13\u4e1a\u5224\u65ad\u652f\u6491\u51b3\u7b56\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83e\udec1 \u5065\u5eb7\u9700\u6c42<\/h4>\n      <p>\u4e8c\u697c\u4e09\u4e2a\u5367\u5ba4\u5e0c\u671b\u914d\u7f6e\u6d01\u51c0\u65b0\u98ce\u4f9b\u7ed9\uff0c\u786e\u4fdd\u591c\u95f4\u7761\u7720\u65f6\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u3002\u65b0\u98ce\u9700\u517c\u987e\u51c0\u5316\u6548\u7387\u4e0e\u9759\u97f3\u8fd0\u884c\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 2. \u9700\u6c42\u4e0e\u75db\u70b9\u8bca\u65ad -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s2\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">2<\/span>\u9700\u6c42\u4e0e\u75db\u70b9\u8bca\u65ad<\/h2>\n\n  <div class=\"value-box\">\n    <table>\n      <thead><tr><th style=\"width:80px\">\u9700\u6c42\u7ef4\u5ea6<\/th><th style=\"width:auto\">\u5177\u4f53\u8868\u73b0<\/th><th style=\"width:80px\">\u6743\u91cd<\/th><th style=\"width:auto\">\u8bca\u65ad\u7ed3\u8bba<\/th><\/tr><\/thead>\n      <tbody>\n        <tr>\n          <td>\u6838\u5fc3\u8bc9\u6c42<\/td>\n          <td>\u8282\u80fd\uff08\u964d\u4f4e\u8fd0\u884c\u8d39\u7528\uff09\u3001\u7a33\u5b9a\u3001\u8212\u9002<\/td>\n          <td>\u2605\u2605\u2605\u2605\u2605<\/td>\n          <td><strong>\u4e24\u8054\u4f9b\u662f\u4f18\u9009\u65b9\u6848<\/strong>\u2014\u2014\u7a7a\u6c14\u80fd\u70ed\u6cf5COP\u22652.72\uff0c\u51ac\u5b63\u91c7\u6696\u8f83\u71c3\u6c14\u8282\u7ea640-50%<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7cfb\u7edf\u504f\u597d<\/td>\n          <td>\u660e\u786e\u503e\u5411&#8221;\u5929\u6c34\u5730\u6c34&#8221;\u4e24\u8054\u4f9b\uff0c\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\u5316<\/td>\n          <td>\u2605\u2605\u2605\u2605\u2605<\/td>\n          <td><strong>\u4e0e\u9700\u6c42\u9ad8\u5ea6\u5339\u914d<\/strong>\u2014\u2014\u6c34\u7cfb\u7edf\u5929\u7136\u9002\u914d\u591a\u5c42\u4f4f\u5b85\u7684\u8fdc\u8ddd\u79bb\u8f93\u914d\u9700\u6c42<\/td>\n        <\/tr>\n        <tr>\n          <td>\u9009\u578b\u56f0\u5883<\/td>\n          <td>\u65e5\u7acb\/\u7ea6\u514b\/\u9ea6\u514b\u7ef4\u5c14\u4e09\u5927\u54c1\u724c\u5747\u5728\u8003\u8651\uff0c\u7f3a\u4e4f\u4e13\u4e1a\u5224\u65ad<\/td>\n          <td>\u2605\u2605\u2605\u2605<\/td>\n          <td><strong>\u63a8\u8350\u65e5\u7acb\u6c34\u5885\u9002<\/strong>\u2014\u2014\u8865\u6c14\u589e\u7113\u53d8\u9891\u6da1\u65cb\u538b\u7f29\u673a\uff0c-30\u2103\u5236\u70ed\uff0c\u6210\u90fd\u670d\u52a1\u4f53\u7cfb\u6700\u6210\u719f<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5065\u5eb7\u9700\u6c42<\/td>\n          <td>\u4e8c\u697c\u4e09\u4e2a\u5367\u5ba4\u5e0c\u671b\u6709\u6d01\u51c0\u65b0\u98ce\u4f9b\u7ed9<\/td>\n          <td>\u2605\u2605\u2605\u2605<\/td>\n          <td><strong>\u5206\u533a\u65b0\u98ce\u65b9\u6848<\/strong>\u2014\u2014\u65e5\u7acb\u4e91\u51c0KPI-2525Q3A\/F\u8986\u76d668.4\u33a1\uff0c\u8ba1\u7b97\u65b0\u98ce\u9700\u6c42129m\u00b3\/h<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">\ud83c\udfd4\ufe0f \u4e09\u5c42\u4f4f\u5b85\u56db\u5927\u6280\u672f\u6311\u6218<\/h3>\n  <div class=\"card-grid\">\n    <div class=\"card\">\n      <h4>\ud83c\udf21\ufe0f \u6311\u6218\u4e00\uff1a\u5782\u76f4\u6e29\u5dee<\/h4>\n      <p>\u4e09\u5c42\u4f4f\u5b85\u4ece\u4e00\u697c\u5230\u4e09\u697c\u5b58\u57282~3\u2103\u81ea\u7136\u6e29\u5dee\u3002\u4e00\u697c65.5\u33a1\u5ba2\u9910\u5385\u9700\u5927\u98ce\u91cf\u5feb\u901f\u54cd\u5e94\uff0c\u4e09\u697c46\u33a1\u8336\u5ba4\u9700\u72ec\u7acb\u7cbe\u7ec6\u63a7\u5236\uff0c\u4f20\u7edf\u5355\u7cfb\u7edf\u96be\u4ee5\u517c\u987e\u3002<\/p>\n      <p style=\"color:#c83c3c;font-weight:600;margin-top:6px;\">\u2192 \u6c34\u7cfb\u7edf\u5404\u672b\u7aef\u72ec\u7acb\u8c03\u8282 + \u53cc\u5185\u673a\u534f\u540c\u8986\u76d6<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udcb0 \u6311\u6218\u4e8c\uff1a\u8fd0\u884c\u8d39\u7528<\/h4>\n      <p>\u8fd1200\u33a1\u5730\u6696\u9762\u79ef\uff0c\u82e5\u91c7\u7528\u4f20\u7edf\u71c3\u6c14\u58c1\u6302\u7089\uff0c\u51ac\u5b63\u91c7\u6696\u8d39\u7528\u53ef\u89c2\u3002\u4e1a\u4e3b\u5c06&#8221;\u8282\u80fd&#8221;\u5217\u4e3a\u9996\u4f4d\u8bc9\u6c42\u3002<\/p>\n      <p style=\"color:#c83c3c;font-weight:600;margin-top:6px;\">\u2192 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b + 32-20\u8282\u80fd\u7cfb\u7edf\uff0c\u9884\u8ba1\u7efc\u5408\u8282\u770140~50%<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83e\udec1 \u6311\u6218\u4e09\uff1a\u7a7a\u6c14\u8d28\u91cf<\/h4>\n      <p>\u4e8c\u697c\u4e09\u4e2a\u5367\u5ba4\u591c\u95f4\u95e8\u7a97\u5173\u95ed\u65f6\uff0cCO\u2082\u6613\u79ef\u805a\u5f71\u54cd\u7761\u7720\u3002\u65b0\u98ce\u9700\u89e3\u51b3\u5bc6\u95ed\u7a7a\u95f4\u6362\u6c14\u95ee\u9898\u3002<\/p>\n      <p style=\"color:#c83c3c;font-weight:600;margin-top:6px;\">\u2192 \u65e5\u7acb\u4e91\u51c0\u65b0\u98ce\u72ec\u7acb\u4f9b\u7ed9\uff0c\u4e09\u6863\u53ef\u8c03\uff0c\u6700\u4f4e23.5dB(A)<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udd27 \u6311\u6218\u56db\uff1a\u54c1\u724c\u51b3\u7b56<\/h4>\n      <p>\u4e09\u5927\u4e24\u8054\u4f9b\u54c1\u724c\u5404\u6709\u6280\u672f\u4f18\u52bf\uff0c\u4e1a\u4e3b\u7f3a\u4e4f\u6a2a\u5411\u5bf9\u6bd4\u7684\u4e13\u4e1a\u5224\u65ad\u4f9d\u636e\u3002<\/p>\n      <p style=\"color:#c83c3c;font-weight:600;margin-top:6px;\">\u2192 \u4ece\u672c\u5730\u552e\u540e\u3001\u4f4e\u6e29\u5236\u70ed\u3001\u5b89\u88c5\u4f53\u7cfb\u4e09\u4e2a\u7ef4\u5ea6\u63d0\u4f9b\u51b3\u7b56\u652f\u6491<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 3. \u8bbe\u8ba1\u7406\u5ff5 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s3\">\n  <h2 class=\"section-title\"><span class=\"num\">3<\/span>\u8bbe\u8ba1\u7406\u5ff5<\/h2>\n\n  <div class=\"card-grid\">\n    <div class=\"card\">\n      <h4>\ud83d\udca1 \u6838\u5fc3\u7406\u5ff5\uff1a\u7528\u80fd\u6548\u6362\u957f\u671f\u4ef7\u503c<\/h4>\n      <p>\u4e0d\u8ffd\u6c42\u6700\u4f4e\u7684\u521d\u6295\u6210\u672c\uff0c\u800c\u662f\u8ffd\u6c42<strong>20\u5e74\u5168\u751f\u547d\u5468\u671f\u603b\u6210\u672c\u6700\u4f4e<\/strong>\u3002\u4e24\u8054\u4f9b\u7cfb\u7edf\u521d\u6295\u9ad8\u4e8e\u58c1\u6302\u7089\u65b9\u6848\uff0c\u4f46\u6bcf\u5e74\u8282\u7701\u7684\u8fd0\u884c\u8d39\u7528\u57283~5\u5e74\u5185\u5373\u53ef\u8986\u76d6\u5dee\u4ef7\uff0c\u6b64\u540e\u6bcf\u5e74\u90fd\u662f\u51c0\u8282\u7701\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udd27 \u5de5\u827a\u7406\u5ff5\uff1a\u7cbe\u5de5\u51b3\u5b9a\u6548\u679c<\/h4>\n      <p>\u4e24\u8054\u4f9b\u662f&#8221;\u4e09\u5206\u8bbe\u5907\u3001\u4e03\u5206\u5b89\u88c5&#8221;\u7684\u7cfb\u7edf\u3002PPR\u70ed\u7194\u8fde\u63a5\u5de5\u827a\u3001\u538b\u5dee\u65c1\u901a\u9600\u8bbe\u7f6e\u3001\u7cfb\u7edf\u6ce8\u6c34\u6253\u538b\u4fdd\u538b\u2014\u2014\u6bcf\u4e00\u4e2a\u7ec6\u8282\u5931\u8bef\u90fd\u4f1a\u5bfc\u81f4\u80fd\u8017\u4e0a\u5347\u6216\u6545\u969c\u9891\u53d1\u3002\u9f99\u8109\u6696\u901a\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5168\u6d41\u7a0b\u7ba1\u63a7\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83c\udf21\ufe0f \u8212\u9002\u7406\u5ff5\uff1a\u5206\u5c42\u72ec\u7acb\u7cbe\u51c6\u63a7\u6e29<\/h4>\n      <p>\u4e09\u5c42\u4f4f\u5b85\u4e0d\u5e94&#8221;\u4e00\u5200\u5207&#8221;\u63a7\u6e29\u3002\u6c34\u7cfb\u7edf\u7684\u5929\u7136\u4f18\u52bf\u662f\u5404\u672b\u7aef\u72ec\u7acb\u8c03\u8282\u2014\u2014\u6bcf\u4e2a\u533a\u57df\u7684\u6e29\u5ea6\u3001\u542f\u505c\u5747\u72ec\u7acb\u63a7\u5236\uff0c\u4e92\u4e0d\u5e72\u6270\uff0c\u5b9e\u73b0\u5168\u5c4b\u5dee\u5f02\u5316\u8212\u9002\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udccb \u670d\u52a1\u7406\u5ff5\uff1a\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9<\/h4>\n      <p>\u4ece\u65bd\u5de5\u4ea4\u4ed8\u219210\u5e74\u80fd\u8017\u8ddf\u8e2a\u2192\u5e74\u5ea6\u56de\u8bbf\u2192\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae\uff0c\u5f62\u6210\u5b8c\u6574\u7684\u670d\u52a1\u95ed\u73af\u3002\u8ba9\u5ba2\u6237&#8221;\u7528\u5f97\u8d77\u3001\u7528\u5f97\u660e\u767d&#8221;\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 4. \u8bbe\u8ba1\u4f9d\u636e -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s4\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">4<\/span>\u8bbe\u8ba1\u4f9d\u636e<\/h2>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:200px\">\u6807\u51c6\/\u89c4\u8303<\/th><th>\u5e94\u7528\u8303\u56f4<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>GB 50736-2012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td><td>\u7a7a\u8c03\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97\u3001\u7cfb\u7edf\u8bbe\u8ba1<\/td><\/tr>\n        <tr><td>JGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/td><td>\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\u3001\u6c34\u6e29\u8bbe\u5b9a\u3001\u65bd\u5de5\u9a8c\u6536<\/td><\/tr>\n        <tr><td>JGJ\/T 440-2018\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300b<\/td><td>\u65b0\u98ce\u91cf\u8ba1\u7b97\u3001\u98ce\u53e3\u5e03\u7f6e<\/td><\/tr>\n        <tr><td>GB 20665-2015\u300a\u623f\u95f4\u7a7a\u6c14\u8c03\u8282\u5668\u80fd\u6548\u9650\u5b9a\u503c\u53ca\u80fd\u6548\u7b49\u7ea7\u300b<\/td><td>\u8bbe\u5907\u80fd\u6548\u7b49\u7ea7\u53c2\u8003<\/td><\/tr>\n        <tr><td>\u65e5\u7acb\u6c34\u5885\u9002\u4ea7\u54c1\u6280\u672f\u624b\u518c<\/td><td>\u4e3b\u673a\u9009\u578b\u3001\u914d\u7ba1\u539f\u5219\u3001\u5b89\u88c5\u89c4\u8303<\/td><\/tr>\n        <tr><td>\u9f99\u8109\u6696\u901a\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u4f01\u4e1a\u6807\u51c6<\/td><td>\u65bd\u5de5\u5de5\u827a\u3001\u9a8c\u6536\u6307\u6807\u5168\u6d41\u7a0b\u7ba1\u63a7<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 5. \u914d\u7f6e\u603b\u89c8 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s5\">\n  <h2 class=\"section-title\"><span class=\"num\">5<\/span>\u914d\u7f6e\u603b\u89c8<\/h2>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:100px\">\u7cfb\u7edf<\/th><th>\u6838\u5fc3\u8bbe\u5907<\/th><th>\u5173\u952e\u53c2\u6570<\/th><th>\u8986\u76d6\u8303\u56f4<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\ud83c\udf2c\ufe0f \u7a7a\u8c03\u7cfb\u7edf<\/td><td>\u65e5\u7acb RAS-252FPUENY2Q\/M + RFP\u7cfb\u5217\u98ce\u673a\u76d8\u7ba1\u00d77\u53f0<\/td><td>\u5236\u51b725.2kW \/ \u5236\u70ed28.0kW \/ \u8d85\u914d\u7387164.7%<\/td><td>187.55\u33a1 \/ \u4e09\u5c42\u5168\u57df<\/td><\/tr>\n        <tr><td>\ud83d\udd25 \u5730\u6696\u7cfb\u7edf<\/td><td>32-20\u8282\u80fd\u7cfb\u7edf \/ PERT dn20\u00d7en2.0 \/ 14\u56de\u8def<\/td><td>\u603b\u70ed\u8d1f\u837723,826W \/ 32-20\u8282\u80fd\u964d\u4f4e15-20%\u80fd\u8017<\/td><td>198.55\u33a1 \/ \u4e09\u5c42\u5168\u57df<\/td><\/tr>\n        <tr><td>\ud83e\udec1 \u65b0\u98ce\u7cfb\u7edf<\/td><td>\u65e5\u7acb\u4e91\u51c0 KPI-2525Q3A\/F<\/td><td>\u989d\u5b9a250m\u00b3\/h \/ \u6700\u4f4e23.5dB(A) \/ \u4e09\u6863\u53ef\u8c03<\/td><td>\u4e8c\u697c\u4e09\u5367\u5ba468.4\u33a1<\/td><\/tr>\n        <tr><td>\ud83c\udfae \u63a7\u5236\u7cfb\u7edf<\/td><td>\u65e5\u7acbWiFi\u7ebf\u63a7\u5668\uff08\u6309\u533a\u57df\u914d\u7f6e\uff09<\/td><td>\u8fdc\u7a0bAPP\u63a7\u5236 \/ \u5404\u533a\u57df\u72ec\u7acb\u8c03\u6e29<\/td><td>\u5404\u529f\u80fd\u533a\u72ec\u7acb\u8c03\u8282<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 6. \u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u914d\u7f6e -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s6\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">6<\/span>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u914d\u7f6e<\/h2>\n\n  <h3 class=\"sub-title\">6.1 \u5ba4\u5185\u673a\u914d\u7f6e\u660e\u7ec6<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u697c\u5c42\/\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u7279\u70b9<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u4e00\u697c\u5ba2\u9910\u5385\uff08\u4e3b\uff09<\/td><td>65.5\u33a1<\/td><td>RFP-136WAR\/DBT<\/td><td>8,100W<\/td><td>\u4e3b\u5185\u673a\uff0c\u98ce\u91cf1,360m\u00b3\/h<\/td><\/tr>\n        <tr><td>\u4e00\u697c\u5ba2\u9910\u5385\uff08\u8f85\uff09<\/td><td>65.5\u33a1<\/td><td>RFP-102WAR\/DBT<\/td><td>6,400W<\/td><td>\u8f85\u52a9\u5185\u673a\uff0c\u534f\u540c\u8986\u76d6\u5927\u7a7a\u95f4<\/td><\/tr>\n        <tr><td>\u4e00\u697c\u5367\u5ba4<\/td><td>7.65\u33a1<\/td><td>RFP-34WAR\/DBT<\/td><td>2,500W<\/td><td>\u7cbe\u51c6\u5339\u914d\u5c0f\u7a7a\u95f4<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td>30.3\u33a1<\/td><td>RFP-119WAR\/DBT<\/td><td>6,810W<\/td><td>\u4f4e\u81f335dB(A)\u9759\u97f3\u8fd0\u884c<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u6b21\u5367+\u8863\u5e3d\u95f4<\/td><td>19.7\u33a1<\/td><td>RFP-68WAR\/DBT<\/td><td>4,300W<\/td><td>\u8d85\u8584192mm\u673a\u8eab<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u6b21\u5367<\/td><td>18.4\u33a1<\/td><td>RFP-68WAR\/DBT<\/td><td>4,300W<\/td><td>\u8d85\u8584192mm\u673a\u8eab<\/td><\/tr>\n        <tr><td>\u4e09\u697c\u8336\u5ba4<\/td><td>46\u33a1<\/td><td>RFP-153WAR\/DBT<\/td><td>9,100W<\/td><td>\u5927\u98ce\u91cf\uff0c1,530m\u00b3\/h<\/td><\/tr>\n        <tr class=\"highlight\"><td><strong>\u5408\u8ba1<\/strong><\/td><td><strong>187.55\u33a1<\/strong><\/td><td><strong>7\u53f0<\/strong><\/td><td><strong>41,510W<\/strong><\/td><td>\u2014<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">6.2 \u5ba4\u5916\u4e3b\u673a\u53c2\u6570<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:180px\">\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u578b\u53f7<\/td><td>RAS-252FPUENY2Q\/M<\/td><\/tr>\n        <tr><td>\u5236\u51b7\u91cf \/ \u5236\u70ed\u91cf<\/td><td>25.2kW \/ 28.0kW<\/td><\/tr>\n        <tr><td>\u538b\u7f29\u673a<\/td><td>\u8865\u6c14\u589e\u7113\u53d8\u9891\u6da1\u65cb\uff08\u65e5\u7acb\u81ea\u7814\uff09<\/td><\/tr>\n        <tr><td>\u4f4e\u6e29\u5236\u70ed\u8303\u56f4<\/td><td>\u5236\u70ed -30\u2103 ~ 28\u2103<\/td><\/tr>\n        <tr><td>\u5236\u70edCOP\uff08-12\u2103\/35\u2103\uff09<\/td><td>2.72<\/td><\/tr>\n        <tr><td>\u7535\u6e90\u89c4\u683c<\/td><td>380V \u4e09\u76f8<\/td><\/tr>\n        <tr><td>\u5916\u673a\u566a\u97f3<\/td><td>55dB(A)<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">6.3 \u8d85\u914d\u7387\u8bf4\u660e<\/h3>\n  <div class=\"value-box\">\n    <p style=\"font-size:14px;\">\u5ba4\u5185\u673a\u603b\u51b7\u91cf 41,510W \u00f7 \u5ba4\u5916\u673a\u5236\u51b7\u91cf 25,200W = <strong style=\"color:#c83c3c;font-size:18px;\">164.7%<\/strong><\/p>\n    <p style=\"font-size:13px;color:#888;margin-top:6px;\">\u5929\u6c34\u5730\u6c34\u7cfb\u7edf\u4e3a\u6c34\u7cfb\u7edf\u8f93\u914d\uff0c\u5185\u673a\u4e3a\u98ce\u673a\u76d8\u7ba1\uff08\u975e\u6c1f\u7cfb\u7edf\u5206\u6b67\u7ba1\u8fde\u63a5\uff09\uff0c\u5404\u672b\u7aef\u901a\u8fc7\u6c34\u9600\u72ec\u7acb\u63a7\u5236\u542f\u505c\u3002\u672c\u8d85\u914d\u7387\u4e3a\u5bb9\u91cf\u914d\u7f6e\u53c2\u8003\u503c\uff0c\u5b9e\u9645\u8fd0\u884c\u65f6\u5404\u533a\u57df\u72ec\u7acb\u8c03\u8282\u3001\u4e0d\u540c\u65f6\u5168\u5f00\uff0c\u7cfb\u7edf\u5904\u4e8e\u5408\u7406\u8fd0\u884c\u533a\u95f4\u3002<\/p>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 7. \u5730\u6696\u7cfb\u7edf\u914d\u7f6e -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s7\">\n  <h2 class=\"section-title\"><span class=\"num\">7<\/span>\u5730\u6696\u7cfb\u7edf\u914d\u7f6e<\/h2>\n\n  <div class=\"value-box\" style=\"background:#fff8f0;border:1px solid #ffe0b2;\">\n    <p style=\"font-size:14px;font-weight:600;color:#c83c3c;\">\u2b50 32-20\u8282\u80fd\u7cfb\u7edf<\/p>\n    <p style=\"font-size:14px;color:#555;margin-top:4px;\">DN32\u4e3b\u7ba1 + 20mm\u52a0\u5bc6\u76d8\u7ba1\uff0c\u540c\u7b49\u6c34\u6e29\u4e0b\u6563\u70ed\u9762\u79ef\u66f4\u5927\u3001\u6c34\u963b\u66f4\u5c0f\uff0c\u53ef\u964d\u4f4e\u4f9b\u6c34\u6e29\u5ea63~5\u2103\uff0c\u8f83\u4f20\u7edf\u6807\u51c6\u65b9\u6848<strong>\u964d\u4f4e15-20%\u80fd\u8017<\/strong>\u3002<\/p>\n  <\/div>\n\n  <h3 class=\"sub-title\">7.1 \u5730\u6696\u56de\u8def\u914d\u7f6e<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th>\u697c\u5c42\/\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u76d8\u7ba1\u578b\u53f7<\/th><th>\u56de\u8def\u6570<\/th><th>\u5206\u96c6\u6c34\u5668<\/th><th>\u70ed\u8d1f\u8377<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u4e00\u697c\u5ba2\u9910\u5385<\/td><td>65.5\u33a1<\/td><td>PERT dn20\u00d7en2.0<\/td><td>4\u8def<\/td><td>1\u5957<\/td><td>11,207W<\/td><\/tr>\n        <tr><td>\u4e00\u697c\u5367\u5ba4<\/td><td>7.65\u33a1<\/td><td>PERT dn20\u00d7en2.0<\/td><td>1\u8def<\/td><td>1\u5957<\/td><td>918W<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td>30.3\u33a1<\/td><td>PERT dn20\u00d7en2.0<\/td><td>2\u8def<\/td><td>2\u5957<\/td><td>3,636W<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u6b21\u5367+\u8863\u5e3d\u95f4<\/td><td>19.7\u33a1<\/td><td>PERT dn20\u00d7en2.0<\/td><td>2\u8def<\/td><td>2\u5957<\/td><td>2,364W<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u6b21\u5367+\u8fc7\u9053<\/td><td>29.4\u33a1<\/td><td>PERT dn20\u00d7en2.0<\/td><td>2\u8def<\/td><td>2\u5957<\/td><td>3,528W<\/td><\/tr>\n        <tr><td>\u4e09\u697c\u8336\u5ba4<\/td><td>46\u33a1<\/td><td>PERT dn20\u00d7en2.0<\/td><td>3\u8def<\/td><td>3\u5957<\/td><td>5,520W<\/td><\/tr>\n        <tr class=\"highlight\"><td><strong>\u5408\u8ba1<\/strong><\/td><td><strong>198.55\u33a1<\/strong><\/td><td>\u2014<\/td><td><strong>14\u8def<\/strong><\/td><td>\u2014<\/td><td><strong>23,826W<\/strong><\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">7.2 \u8bbe\u8ba1\u51b3\u7b56\u8bf4\u660e<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:160px\">\u8bbe\u8ba1\u51b3\u7b56<\/th><th>\u4e3a\u4ec0\u4e48\u8fd9\u4e48\u505a<\/th><th>\u5bf9\u60a8\u7684\u4ef7\u503c<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b<\/td><td>\u7a7a\u6c14\u80fd\u70ed\u6cf5\u4ea7\u751f\u51b7\/\u70ed\u6c34\uff0c\u901a\u8fc7\u6c34\u7ba1\u8f93\u914d\u5230\u5404\u672b\u7aef\uff1b\u5236\u70edCOP 2.72\uff0c1\u5ea6\u7535\u642c\u8fd0\u8fd13\u500d\u70ed\u91cf<\/td><td>\u51ac\u5b63\u91c7\u6696\u8d39\u7528\u8f83\u71c3\u6c14\u8282\u770140~50%<\/td><\/tr>\n        <tr><td>32-20\u8282\u80fd\u7cfb\u7edf<\/td><td>DN32\u4e3b\u7ba1\u6d41\u91cf\u5145\u8db3+20mm\u52a0\u5bc6\u76d8\u7ba1\u6563\u70ed\u9762\u79ef\u66f4\u5927\uff0c\u53ef\u964d\u4f4e\u4f9b\u6c34\u6e29\u5ea63~5\u2103<\/td><td>\u5728\u70ed\u6cf5\u57fa\u7840\u4e0a\u518d\u964d\u4f4e15-20%\u80fd\u8017<\/td><\/tr>\n        <tr><td>14\u8def\u5206\u8def\u63a7\u5236<\/td><td>\u6bcf\u533a\u57df\u72ec\u7acb\u56de\u8def+\u72ec\u7acb\u5206\u96c6\u6c34\u5668\uff0c\u6c34\u529b\u5e73\u8861\u7cbe\u51c6<\/td><td>\u5404\u623f\u95f4\u6e29\u5ea6\u5747\u5300\uff0c\u8fdc\u7aef\u4e5f\u70ed\u5f97\u8d77\u6765<\/td><\/tr>\n        <tr><td>WiFi\u5ba4\u6e29\u8054\u52a8<\/td><td>\u5ba4\u6e29\u8fbe\u6807\u540e\u7cfb\u7edf\u81ea\u52a8\u8c03\u8282\uff0c\u675c\u7edd\u65e0\u6548\u4ea7\u70ed<\/td><td>\u6bcf\u6708\u9884\u8ba1\u8282\u770110~25%\u80fd\u8017<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 8. \u65b0\u98ce\u7cfb\u7edf\u914d\u7f6e -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s8\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">8<\/span>\u65b0\u98ce\u7cfb\u7edf\u914d\u7f6e<\/h2>\n\n  <p style=\"font-size:14px;color:#555;margin-bottom:10px;\">\u670d\u52a1\u8303\u56f4\uff1a\u4e8c\u697c\u4e09\u4e2a\u5367\u5ba4\uff08\u4e3b\u536730.3\u33a1 + \u6b21\u536719.7\u33a1 + \u6b21\u536718.4\u33a1\uff09\uff0c\u5408\u8ba1 <strong>68.4\u33a1<\/strong><\/p>\n\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:180px\">\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u65b0\u98ce\u673a\u578b\u53f7<\/td><td>\u65e5\u7acb\u4e91\u51c0 KPI-2525Q3A\/F<\/td><\/tr>\n        <tr><td>\u989d\u5b9a\u98ce\u91cf<\/td><td>250 \/ 170 \/ 120 m\u00b3\/h\uff08\u4e09\u6863\u53ef\u8c03\uff09<\/td><\/tr>\n        <tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td>32.5 \/ 28.5 \/ 23.5 dB(A)<\/td><\/tr>\n        <tr><td>\u8ba1\u7b97\u65b0\u98ce\u9700\u6c42<\/td><td>129 m\u00b3\/h\uff08\u6309JGJ\/T440-2018\u8ba1\u7b97\uff09<\/td><\/tr>\n        <tr><td>\u9001\u98ce\u53e3 \/ \u6392\u98ce\u53e3<\/td><td>\u54045\u4e2a<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"card-grid\" style=\"margin-top:12px;\">\n    <div class=\"card\">\n      <h4>\u2705 \u9009\u578b\u5408\u7406\u6027<\/h4>\n      <p>\u989d\u5b9a\u98ce\u91cf250m\u00b3\/h\uff0c\u9700\u6c42129m\u00b3\/h\uff0c\u4f59\u91cf\u5145\u8db3\uff0c\u53ef\u957f\u671f\u4f4e\u6863\u8fd0\u884c\u4fdd\u6301\u9759\u97f3\u8282\u80fd\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udd07 \u9759\u97f3\u4fdd\u969c<\/h4>\n      <p>\u6700\u4f4e\u686323.5dB(A)\uff0c\u4f4e\u4e8e\u6b63\u5e38\u7761\u7720\u73af\u5883\u566a\u97f3\u6807\u51c6\uff0830dB(A)\uff09\uff0c\u4e0d\u5f71\u54cd\u591c\u95f4\u4f11\u606f\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udca8 \u6c14\u6d41\u7ec4\u7ec7<\/h4>\n      <p>\u6bcf\u5367\u5ba4\u72ec\u7acb\u9001\u98ce\u53e3+\u72ec\u7acb\u6392\u98ce\u53e3\uff0c\u5f62\u6210\u5b9a\u5411\u6c14\u6d41\u8def\u5f84\uff0c\u907f\u514d\u77ed\u6d41\u548c\u6b7b\u89d2\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div>\n\n<footer class=\"footer\">\n  \u00a92004-2026 \u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5168\u6d41\u7a0b\u53ef\u89c6\u5316<br>\n  \u5357\u5bcc\u68ee\u5e97\uff1a028-86131795 \uff5c \u5317\u5bcc\u68ee\u5e97\uff1a028-65272586\n<\/footer>\n\n<\/div>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\" style=\"font-size:28px\"><strong>\u7b2c\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/strong><\/p>\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u7cbe\u5de5\u516d\u6b65\u6cd5\u3001\u65bd\u5de5\u9a8c\u6536\u3001\u5de5\u827a\u9a8c\u8bc1<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n<div aria-labelledby=\"accordion-item-2\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u00b7\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u6863\u6848\uff5c\u7b2c\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1\",\n  \"description\": \"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1\u6863\u6848\u3002\",\n  \"author\": {\"@type\": \"Organization\", \"name\": \"\u9f99\u8109\u6696\u901a\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"\u9f99\u8109\u6696\u901a\"}\n}\n<\/script>\n<style>\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{scroll-behavior:smooth;font-size:16px}\nbody{font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#333;line-height:1.8;background:#f5f5f5}\n\n\/* Breadcrumb (sticky) *\/\n.breadcrumb{position:-webkit-sticky;position:sticky;top:0;z-index:100;background:#fff;border-bottom:1px solid #e3e3e3;box-shadow:0 2px 10px rgba(0,0,0,.08);}\n.breadcrumb .inner{max-width:960px;margin:0 auto;padding:11px 16px;display:flex;align-items:center;flex-wrap:wrap;gap:4px 6px;font-size:13px;line-height:1.5;}\n.breadcrumb a{color:#0f3460;text-decoration:none;white-space:nowrap;}\n.breadcrumb a:hover{color:#c83c3c;text-decoration:underline;}\n.breadcrumb .sep{color:#c4c4c4;margin:0 2px;white-space:nowrap;}\n.breadcrumb .cur{color:#555;font-weight:600;white-space:nowrap;}\n\n\/* Header *\/\n.header{position:relative;color:#fff;padding:56px 24px;text-align:center;overflow:hidden;background:#0f3460 url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-06.png') center\/cover no-repeat;}\n.header::before{content:\"\";position:absolute;inset:0;z-index:0;background:linear-gradient(180deg,rgba(8,20,38,.78) 0%,rgba(8,20,38,.42) 50%,rgba(8,20,38,.76) 100%),radial-gradient(ellipse at center top,rgba(0,0,0,.34),transparent 60%),radial-gradient(ellipse at center bottom,rgba(0,0,0,.38),transparent 56%);}\n.header>*{position:relative;z-index:1;}\n.header h1{text-shadow:0 2px 14px rgba(0,0,0,.5);}\n.header .badge{display:inline-block;background:#c83c3c;padding:3px 14px;border-radius:4px;font-size:12px;letter-spacing:1px;margin-bottom:12px}\n.header h1{font-size:24px;margin-bottom:6px}\n.header .meta{font-size:14px;color:#eaf1f8;display:flex;flex-wrap:wrap;justify-content:center;gap:8px 20px;margin-top:10px}\n.header .meta span{color:#d6e1ec}\n\n\/* Container *\/\n.container{max-width:960px;margin:0 auto;padding:0 16px}\n\n\/* Page header info *\/\n.page-info{background:#fff;border-radius:8px;box-shadow:0 1px 6px rgba(0,0,0,.06);padding:18px 24px;margin:20px 0;display:flex;flex-wrap:wrap;gap:10px 30px;font-size:14px}\n.page-info .info-item{display:flex;gap:6px}\n.page-info .info-label{color:#888}\n.page-info .info-value{font-weight:600;color:#1a1a2e}\n\n\/* TOC *\/\n.toc{background:#fff;border-radius:8px;box-shadow:0 1px 6px rgba(0,0,0,.06);padding:18px 24px;margin:16px 0}\n.toc h3{font-size:15px;color:#c83c3c;margin-bottom:8px;border-bottom:2px solid #c83c3c;padding-bottom:6px}\n.toc ol{list-style:none;counter-reset:item;padding-left:0}\n.toc ol li{counter-increment:item;padding:4px 0;font-size:14px;border-bottom:1px dotted #eee}\n.toc ol li:last-child{border-bottom:none}\n.toc ol li::before{content:counter(item) \". \";color:#c83c3c;font-weight:700;margin-right:4px}\n.toc ol li a{color:#555;text-decoration:none}\n.toc ol li a:hover{color:#c83c3c;text-decoration:underline}\n\n\/* Section *\/\n.section{padding:30px 0}\n.section-title{font-size:20px;color:#1a1a2e;margin-bottom:18px;padding-bottom:8px;border-bottom:3px solid #c83c3c;display:flex;align-items:center;gap:8px}\n.section-title .num{display:inline-flex;align-items:center;justify-content:center;background:#c83c3c;color:#fff;width:26px;height:26px;border-radius:50%;font-size:13px;flex-shrink:0}\n.section-title .sub{font-size:13px;color:#888;font-weight:400;margin-left:auto}\n\n\/* Sub title *\/\nh3.sub-title{font-size:16px;color:#1a1a2e;margin:18px 0 10px;padding-left:10px;border-left:3px solid #c83c3c}\nh4.sub-sub{font-size:15px;color:#c83c3c;margin:14px 0 8px;font-weight:600}\n\n\/* Cards grid *\/\n.card-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(280px,1fr));gap:12px;margin:12px 0}\n.card{background:#fff;border-radius:8px;padding:16px 18px;box-shadow:0 1px 4px rgba(0,0,0,.06);border-left:3px solid #c83c3c}\n.card h4{font-size:15px;color:#1a1a2e;margin-bottom:4px}\n.card p{font-size:14px;color:#555;line-height:1.6}\n\n\/* Table *\/\n.table-wrap{overflow-x:auto;margin:12px 0;border-radius:6px;box-shadow:0 1px 4px rgba(0,0,0,.06)}\ntable{width:100%;border-collapse:collapse;font-size:14px;background:#fff}\nthead{background:#1a1a2e;color:#fff}\nth{padding:9px 12px;text-align:left;font-weight:600;font-size:13px}\ntd{padding:9px 12px;border-bottom:1px solid #eee;font-size:13px}\ntr:last-child td{border-bottom:none}\ntr:nth-child(even){background:#fafafa}\n.highlight{background:#fff3e0!important}\n.highlight td{font-weight:600;color:#c83c3c}\n\n\/* Value highlight box *\/\n.value-box{background:#fff;border-radius:8px;padding:16px 20px;box-shadow:0 1px 4px rgba(0,0,0,.06);margin:12px 0;border:1px solid #e8e8e8}\n.value-box table{border:none;box-shadow:none;margin:0}\n\n\/* Tag *\/\n.tag{display:inline-block;background:#f0f0f0;color:#555;padding:2px 10px;border-radius:10px;font-size:12px;margin:2px}\n\n\/* Promise list *\/\n.promise-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(260px,1fr));gap:10px;margin:12px 0}\n.promise-item{background:#fff;border-radius:6px;padding:12px 16px;border:1px solid #eee;display:flex;align-items:flex-start;gap:8px;font-size:14px}\n.promise-item .icon{color:#c83c3c;font-size:18px;flex-shrink:0;line-height:1.4}\n\n\/* Milestone *\/\n.milestone-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(180px,1fr));gap:10px;margin:12px 0}\n.milestone{background:#fff;border-radius:8px;padding:14px;text-align:center;box-shadow:0 1px 4px rgba(0,0,0,.06);border-top:3px solid #c83c3c}\n.milestone .phase{font-size:12px;color:#c83c3c;font-weight:600}\n.milestone .time{font-size:15px;font-weight:700;color:#1a1a2e;margin:4px 0;line-height:1.4}\n.milestone .desc{font-size:12px;color:#888}\n\n\/* CTA *\/\n.cta-line{text-align:center;background:#1a1a2e;color:#fff;padding:20px;border-radius:8px;margin:20px 0}\n.cta-line p{font-size:14px;color:#ccc;margin-top:4px}\n\n\/* Footer *\/\n.footer{text-align:center;padding:24px 16px;font-size:13px;color:#888;border-top:1px solid #e0e0e0;margin-top:20px}\n\n\/* Phase2 \u4e13\u5c5e\uff1a\u5de5\u827a\u6b65\u9aa4 *\/\n.step-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(300px,1fr));gap:12px;margin:12px 0}\n.step-card{background:#fff;border-radius:8px;padding:16px 18px;box-shadow:0 1px 4px rgba(0,0,0,.06);border-top:3px solid #c83c3c}\n.step-card .step-no{display:inline-flex;align-items:center;justify-content:center;background:#c83c3c;color:#fff;width:24px;height:24px;border-radius:50%;font-size:13px;font-weight:700;margin-right:8px;flex-shrink:0}\n.step-card h4{display:inline-block;font-size:15px;color:#1a1a2e;margin-bottom:6px}\n.step-card p{font-size:14px;color:#555;line-height:1.6}\n.step-card .point{color:#c83c3c;font-weight:600;font-size:13px;margin-top:6px;display:block}\n\n\/* \u5b9e\u62cd\u5360\u4f4d\u69fd *\/\n.photo-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(220px,1fr));gap:12px;margin:12px 0}\n.photo-grid figure{margin:0;background:#fff;border:1px solid #eee;border-radius:8px;overflow:hidden;box-shadow:0 1px 5px rgba(0,0,0,.06)}\n.photo-grid img{display:block;width:100%;aspect-ratio:4\/3;object-fit:cover;border:0}\n.photo-grid figcaption{font-size:12px;color:#666;padding:6px 9px;text-align:center;background:#fafafa}\n.photo-place{border:2px dashed #c8a0a0;border-radius:8px;background:#fdf6f6;min-height:150px;display:flex;flex-direction:column;justify-content:center;align-items:center;gap:4px;padding:12px;text-align:center}\n.photo-place .ph-group{font-size:12px;color:#c83c3c;font-weight:600}\n.photo-place .ph-hint{font-size:13px;color:#999}\n.photo-place .ph-name{font-size:11px;color:#bbb;font-family:monospace;word-break:break-all}\n.photo-note{font-size:13px;color:#888;background:#fff;border-left:3px solid #c83c3c;padding:10px 14px;border-radius:4px;margin:10px 0}\n\n\/* \u6548\u679c\u9a8c\u8bc1\u6570\u636e\u5361 *\/\n.verify-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:10px;margin:12px 0}\n.verify-card{background:#fff;border-radius:8px;padding:14px 16px;box-shadow:0 1px 4px rgba(0,0,0,.06);border-left:3px solid #c83c3c;text-align:center}\n.verify-card .v-num{font-size:20px;font-weight:800;color:#c83c3c}\n.verify-card .v-label{font-size:13px;color:#888;margin-top:4px}\n\n\/* \u5f15\u7528\/\u5ba2\u6237\u91d1\u53e5 *\/\n.quote{background:#fff8f0;border-left:4px solid #c83c3c;padding:14px 18px;border-radius:4px;margin:12px 0;font-style:italic;color:#555;font-size:14px}\n.quote .q-by{display:block;margin-top:8px;font-style:normal;font-size:13px;color:#c83c3c;font-weight:600}\n\n\/* \u94fe\u63a5\u5361\uff08\u77e5\u8bc6\u5ef6\u4f38\uff09 *\/\n.link-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(220px,1fr));gap:10px;margin:12px 0}\n.link-card{display:block;background:#fff;border-radius:8px;padding:14px 16px;box-shadow:0 1px 4px rgba(0,0,0,.06);border:1px solid #eee;text-decoration:none;color:#333;transition:.2s}\n.link-card:hover{border-color:#c83c3c;transform:translateY(-2px)}\n.link-card b{display:block;font-size:14px;color:#1a1a2e;margin-bottom:4px}\n.link-card span{font-size:13px;color:#888}\n\n\/* FAQ *\/\n.faq-item{background:#fff;border-radius:8px;padding:0;margin:10px 0;box-shadow:0 1px 4px rgba(0,0,0,.06);overflow:hidden}\n.faq-item summary{cursor:pointer;padding:14px 18px;font-size:14px;font-weight:600;color:#1a1a2e;list-style:none}\n.faq-item summary::-webkit-details-marker{display:none}\n.faq-item summary::before{content:\"\u25b8 \";color:#c83c3c}\n.faq-item[open] summary::before{content:\"\u25be \"}\n.faq-item .faq-a{padding:0 18px 14px;font-size:14px;color:#555;line-height:1.7}\n\n@media(max-width:767px){body{font-size:14px}.header{padding:44px 16px}.header h1{font-size:18px}.card-grid,.promise-grid,.step-grid,.photo-grid,.verify-grid,.link-grid{grid-template-columns:1fr}.milestone-grid{grid-template-columns:1fr 1fr}table{font-size:12px;overflow-x:auto;display:block;white-space:nowrap}}\n<\/style>\n\n<!-- ============================================================ -->\n<!-- Header -->\n<!-- ============================================================ -->\n<!-- TODO: \u53d1\u5e03\u65f6\u4e24\u6587\u4ef6\u7f6e\u4e8e\u540c\u76ee\u5f55\uff0c\u6216\u628a\u4e0b\u5217 href \u66ff\u6362\u4e3a\u7ebf\u4e0a\u771f\u5b9e URL\uff08\u6ce8\uff1a\u4e00\u9636\u6bb5\u6587\u4ef6\u53d1\u5e03\u65f6\u5efa\u8bae\u547d\u540d\u4e3a gw-zlrfxi-dangan-s1.html\uff09 -->\n<nav class=\"breadcrumb\" aria-label=\"\u9762\u5305\u5c51\u5bfc\u822a\">\n  <div class=\"inner\">\n    <a href=\"https:\/\/longmai-nt.com\/\">\u9f99\u8109\u6696\u901a<\/a>\n    <span class=\"sep\">\u203a<\/span>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u5ba2\u6237\u6863\u6848<\/a>\n    <span class=\"sep\">\u203a<\/span>\n    <a href=\"gw-zlrfxi-dangan-s1.html\">\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u7b2c\u4e00\u9636\u6bb5<\/a>\n    <span class=\"sep\">\u203a<\/span>\n    <span class=\"cur\">\u7b2c\u4e8c\u9636\u6bb5 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/span>\n  <\/div>\n<\/nav>\n\n<header class=\"header\">\n  <div class=\"badge\">\ud83d\udcc1 \u5ba2\u6237\u6863\u6848 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/div>\n  <h1>\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce<\/h1>\n  <div class=\"meta\">\n    <span>\ud83c\udfe0 \u5ba2\u6237\uff1a\u5170\u8001\u5e08<\/span>\n    <span>\ud83d\udccd \u4e2d\u7cae\u745e\u5e9c\u73ba\u9662<\/span>\n    <span>\ud83d\udc64 \u987e\u95ee\uff1a\u9ec4\u52c7 \u00b7 13\u5e74<\/span>\n    <span>\ud83d\udcc5 2026\u5e747\u6708<\/span>\n  <\/div>\n<\/header>\n\n<div class=\"container\">\n\n<!-- ============================================================ -->\n<!-- \u9879\u76ee\u4fe1\u606f -->\n<!-- ============================================================ -->\n<div class=\"page-info\">\n  <div class=\"info-item\"><span class=\"info-label\">\u6863\u6848\u7f16\u53f7\uff1a<\/span><span class=\"info-value\">zlrfxi-tsds-lls-202607<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u623f\u5c4b\u7c7b\u578b\uff1a<\/span><span class=\"info-value\">\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u7a7a\u8c03\u9762\u79ef\uff1a<\/span><span class=\"info-value\">187.55\u33a1<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u5730\u6696\u9762\u79ef\uff1a<\/span><span class=\"info-value\">198.55\u33a1<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u7cfb\u7edf\u7c7b\u578b\uff1a<\/span><span class=\"info-value\">\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b + \u65b0\u98ce<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u9636\u6bb5\uff1a<\/span><span class=\"info-value\">\u7b2c\u4e8c\u9636\u6bb5 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/span><\/div>\n  <div class=\"info-item\"><span class=\"info-label\">\u7248\u672c\uff1a<\/span><span class=\"info-value\">\u6863\u6848\u7248 v2.0<\/span><\/div>\n<\/div>\n\n<!-- ============================================================ -->\n<!-- TOC -->\n<!-- ============================================================ -->\n<nav class=\"toc\">\n  <h3>\ud83d\udcd1 \u7b2c\u4e8c\u9636\u6bb5 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1 \u76ee\u5f55<\/h3>\n  <ol>\n    <li><a href=\"#s9\">\u65bd\u5de5\u4ea4\u4ed8\u603b\u89c8<\/a><\/li>\n    <li><a href=\"#s10\">\u7cbe\u5de5\u516d\u6b65\u6cd5+2 \u5de5\u827a\u6d41\u7a0b<\/a><\/li>\n    <li><a href=\"#s11\">\u5173\u952e\u5de5\u827a\u8282\u70b9\u4e0e\u9a8c\u6536\u6807\u51c6<\/a><\/li>\n    <li><a href=\"#s12\">\u65bd\u5de5\u5b9e\u62cd\u56fe\u96c6\uff08\u5b9e\u666f\u7559\u6863\uff09<\/a><\/li>\n    <li><a href=\"#s13\">\u7cfb\u7edf\u9a8c\u8bc1\u4e0e\u6548\u679c\u4ea4\u4ed8<\/a><\/li>\n    <li><a href=\"#faq\">\u65bd\u5de5\u4ea4\u4ed8\u5e38\u89c1\u95ee\u9898<\/a><\/li>\n    <li><a href=\"#links\">\u77e5\u8bc6\u5ef6\u4f38 \u00b7 \u76f8\u5173\u9605\u8bfb<\/a><\/li>\n  <\/ol>\n<\/nav>\n\n<!-- ============================================================ -->\n<!-- 9. \u65bd\u5de5\u4ea4\u4ed8\u603b\u89c8 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s9\">\n  <h2 class=\"section-title\"><span class=\"num\">9<\/span>\u65bd\u5de5\u4ea4\u4ed8\u603b\u89c8<span class=\"sub\">\u4ece\u65b9\u6848\u5230\u843d\u5730\u7684\u4e09\u4e2a\u9636\u6bb5<\/span><\/h2>\n  <p style=\"font-size:15px;color:#555;margin-bottom:14px;\">\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e3a\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85\uff0c\u7cfb\u7edf\u6db5\u76d6 <strong>\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b<\/strong>\uff08\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a RAS-252FPUENY2Q\/M + 7 \u53f0\u98ce\u673a\u76d8\u7ba1 + 14 \u56de\u8def\u5730\u6696\uff09\u4e0e <strong>\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce<\/strong>\u3002\u65bd\u5de5\u6309\u300c\u9690\u853d\u5de5\u7a0b\u5148\u884c\u3001\u660e\u88c5\u8c03\u8bd5\u6536\u5c3e\u300d\u5206\u4e24\u671f\u63a8\u8fdb\uff0c\u5168\u5468\u671f\u516b\u4e2a\u91cc\u7a0b\u7891\uff0c\u786e\u4fdd\u300c\u6bcf\u6839\u7ba1\u5b50\u7ecf\u5f97\u8d77\u62ac\u5934\u770b\u300d\u3002<\/p>\n\n  <div class=\"value-box\">\n    <table>\n      <thead><tr><th style=\"width:120px\">\u65bd\u5de5\u5206\u671f<\/th><th>\u5305\u542b\u5185\u5bb9<\/th><th style=\"width:140px\">\u5173\u952e\u76ee\u6807<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u4e00\u671f\uff08\u9690\u853d\u5de5\u7a0b\uff09<\/td><td>\u7a7a\u8c03\u6c34\u7ba1 PPR \u70ed\u7194\u94fa\u8bbe\u3001\u5730\u6696 PERT \u76d8\u7ba1\u6577\u8bbe\u3001\u7cfb\u7edf\u4fdd\u538b\u3001\u4e00\u671f\u9690\u853d\u9a8c\u6536<\/td><td>\u7ba1\u9053\u96f6\u9690\u60a3\u3001\u9a8c\u6536\u53ef\u8ffd\u6eaf<\/td><\/tr>\n        <tr><td>\u4e8c\u671f\uff08\u660e\u88c5\u8c03\u8bd5\uff09<\/td><td>\u65b0\u98ce\u7ba1\u9053\u4e0e\u4e3b\u673a\u5b89\u88c5\u3001\u7cfb\u7edf\u6ce8\u6c34\u6253\u538b\u3001\u6c34\u6e29+\u5ba4\u6e29\u53cc\u8054\u52a8\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66<\/td><td>\u6548\u679c\u8fbe\u6807\u3001\u5ba2\u6237\u4f1a\u7528<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">\ud83d\udccd \u516b\u5927\u91cc\u7a0b\u7891<\/h3>\n  <div class=\"milestone-grid\">\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 01<\/div><div class=\"time\">\u65b9\u6848\u4ea4\u5e95<\/div><div class=\"desc\">\u4e09\u65b9\u73b0\u573a\u5b9a\u4f4d\uff0c\u96f6\u8fd4\u5de5<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 02<\/div><div class=\"time\">\u6750\u6599\u8fdb\u573a<\/div><div class=\"desc\">\u8bbe\u5907\u94ed\u724c\u62cd\u7167\u3001\u7ba1\u6750\u6838\u5bf9<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 03<\/div><div class=\"time\">\u7a7a\u8c03\u6c34\u7ba1<\/div><div class=\"desc\">PPR \u70ed\u7194\u3001\u6a2a\u5e73\u7ad6\u76f4<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 04<\/div><div class=\"time\">\u5730\u6696\u76d8\u7ba1<\/div><div class=\"desc\">PERT \u5927\u5f27\u5f2f\u300114 \u56de\u8def<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 05<\/div><div class=\"time\">\u9690\u853d\u9a8c\u6536<\/div><div class=\"desc\">\u4e1a\u4e3b+\u88c5\u4fee+\u65bd\u5de5\u4e09\u65b9\u7b7e<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 06<\/div><div class=\"time\">\u65b0\u98ce\u5b89\u88c5<\/div><div class=\"desc\">\u7ba1\u9053+\u4e3b\u673a+\u98ce\u53e3<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 07<\/div><div class=\"time\">\u7cfb\u7edf\u8c03\u8bd5<\/div><div class=\"desc\">\u6ce8\u6c34\u6253\u538b\u3001\u53cc\u8054\u52a8<\/div><\/div>\n    <div class=\"milestone\"><div class=\"phase\">\u91cc\u7a0b\u7891 08<\/div><div class=\"time\">\u4ea4\u4ed8\u6559\u5b66<\/div><div class=\"desc\">\u64cd\u4f5c+\u7ef4\u4fdd+\u8d28\u4fdd<\/div><\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 10. \u7cbe\u5de5\u516d\u6b65\u6cd5+2 \u5de5\u827a\u6d41\u7a0b -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s10\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">10<\/span>\u7cbe\u5de5\u516d\u6b65\u6cd5+2 \u5de5\u827a\u6d41\u7a0b<span class=\"sub\">\u6838\u5fc3\u65bd\u5de5\u6807\u51c6<\/span><\/h2>\n  <p style=\"font-size:15px;color:#555;margin-bottom:14px;\">\u4e24\u8054\u4f9b\u662f\u300c\u4e09\u5206\u8bbe\u5907\u3001\u4e03\u5206\u5b89\u88c5\u300d\u7684\u7cfb\u7edf\u3002\u672c\u9879\u76ee\u4e25\u683c\u9075\u5faa\u9f99\u8109\u6696\u901a <strong>\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/strong> \u4f01\u4e1a\u6807\u51c6\u2014\u2014\u516d\u6b65\u4e3a\u73b0\u573a\u65bd\u5de5\u5de5\u827a\u95ed\u73af\uff0c+2 \u4e3a\u552e\u524d\u52d8\u6d4b\u8bbe\u8ba1\u4e0e\u552e\u540e\u80fd\u8017\u8ddf\u8e2a\u4e24\u7aef\u7684\u670d\u52a1\u5ef6\u4f38\uff0c\u5f62\u6210\u300c\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\u300d\u7684\u5b8c\u6574\u670d\u52a1\u94fe\u3002<\/p>\n\n  <div class=\"step-grid\">\n    <div class=\"step-card\">\n      <span class=\"step-no\">1<\/span><h4>\u65b9\u6848\u4ea4\u5e95\u4e0e\u73b0\u573a\u5b9a\u4f4d<\/h4>\n      <p>\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u73b0\u573a\u5b9a\u4f4d\uff1a\u5185\u673a\u540a\u88c5\u4f4d\u3001\u6c34\u7ba1\u8d70\u5411\u3001\u51b7\u51dd\u6c34\u5761\u5ea6\u3001\u5916\u673a\u7535\u6e90\u4e0e\u51cf\u9707\u57fa\u7840\u3001\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\uff08\u2265400\u00d7400mm\uff09\u3001\u7ebf\u63a7\u5668\u9884\u7559\u3002\u8f93\u51fa\u5e73\u9762\u5e03\u7f6e\u56fe\uff0c\u529b\u6c42\u96f6\u8fd4\u5de5\u3002<\/p>\n      <span class=\"point\">\u2192 \u672c\u6848 7 \u53f0 RFP \u5185\u673a + 14 \u56de\u8def\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u4e00\u6b21\u5b9a\u51c6<\/span>\n    <\/div>\n    <div class=\"step-card\">\n      <span class=\"step-no\">2<\/span><h4>\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/h4>\n      <p>\u8bbe\u5907\u94ed\u724c\u62cd\u7167\u53d1\u7fa4\uff1b\u7ba1\u6750\u58c1\u539a\u9010\u9879\u6838\u5bf9\uff1b\u65e5\u7acb\u539f\u5382\u8bc1\u660e\u5b58\u6863\uff08\u5077\u4e0d\u8d70\u3001\u6362\u4e0d\u6389\uff09\u3002<\/p>\n      <span class=\"point\">\u2192 \u6c34\u5885\u9002\u4e3b\u673a RAS-252FPUENY2Q\/M\u3001RFP \u5185\u673a\u3001PERT dn20\u00d7en2.0\u3001\u4e91\u51c0\u65b0\u98ce\u673a\u9010\u4ef6\u6838\u9a8c<\/span>\n      <div class=\"photo-grid\">\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u8bbe\u5907\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u6750\u6599\u8fdb\u573a\u9a8c\u6536 \u00b7 \u8bbe\u5907<\/figcaption><\/figure>\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-cljc-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u6750\u6599\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u6750\u6599\u8fdb\u573a\u9a8c\u6536 \u00b7 \u7ba1\u6750<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n    <div class=\"step-card\">\n      <span class=\"step-no\">3<\/span><h4>\u7a7a\u8c03\u6c34\u7ba1\u94fa\u8bbe\uff08PPR \u70ed\u7194\uff09<\/h4>\n      <p>\u6c34\u7cfb\u7edf\u8f93\u914d\u4ee5 PPR \u7ba1\u70ed\u7194\u8fde\u63a5\uff08\u65e0\u660e\u706b\uff09\uff0c\u4e3b\u7ba1 DN32\uff1b\u6a2a\u5e73\u7ad6\u76f4\u3001\u7ba1\u5361\u5747\u5300\u3002\u51b7\u51dd\u6c34\u5761\u5ea6\u22651%\uff08\u6bcf\u7c73 1cm\uff09\u3001\u6ee1\u6c34\u6392\u6c34\u8bd5\u9a8c\u3002\u5168\u7a0b\u6a61\u5851\u4fdd\u6e29\u8fde\u7eed\u65e0\u65ad\u70b9\uff0c\u9632\u7ed3\u9732\u3002\u538b\u5dee\u65c1\u901a\u9600\u4fdd\u62a4\u6c34\u6cf5\u3001\u5e73\u8861\u6c34\u529b\u3002<\/p>\n      <span class=\"point\">\u2192 32-20 \u8282\u80fd\u7cfb\u7edf\uff0cDN32 \u4e3b\u7ba1 + 20mm \u52a0\u5bc6\u76d8\u7ba1<\/span>\n      <div class=\"photo-grid\">\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-glaz-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03PPR\u6c34\u7ba1\u94fa\u8bbe\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u7a7a\u8c03\u6c34\u7ba1\u94fa\u8bbe\uff08PPR \u70ed\u7194\uff09<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n    <div class=\"step-card\">\n      <span class=\"step-no\">4<\/span><h4>\u5730\u6696\u76d8\u7ba1\u6577\u8bbe\uff08PERT \u5927\u5f27\u5f2f\uff09<\/h4>\n      <p>PERT dn20\u00d7en2.0 \u963b\u6c27\u76d8\u7ba1\u5927\u5f27\u5f2f\u6577\u8bbe\uff0c\u95f4\u8ddd\u5747\u5300\uff1b\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5230\u4f4d\uff0814 \u56de\u8def\u3001\u591a\u5957\u72ec\u7acb\u63a7\u5236\uff09\u3002\u76d8\u7ba1\u4fdd\u538b 0.6\u20130.8MPa\u3001\u7a33\u538b\u22651h \u65e0\u6e17\u6f0f\u3002<\/p>\n      <span class=\"point\">\u2192 \u4e00\u697c 4 \u8def \/ \u4e8c\u697c 6 \u8def \/ \u4e09\u697c 3 \u8def + \u4e00\u697c\u5367\u5ba4 1 \u8def<\/span>\n    <\/div>\n    <div class=\"step-card\">\n      <span class=\"step-no\">5<\/span><h4>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536<\/h4>\n      <p>\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u5230\u573a\uff0c\u5bf9\u7167\u56fe\u7eb8\u6838\u9a8c\u7ba1\u9053\u8d70\u5411\u3001\u4fdd\u6e29\u3001\u5761\u5ea6\u3001\u4fdd\u538b\u6570\u636e\uff0c\u7b7e\u5b57\u5b58\u6863\u3002\u5168\u7a0b\u62cd\u7167\u7559\u6863\u53d1\u7fa4\u3002<\/p>\n      <span class=\"point\">\u2192 \u9690\u853d\u524d\u7559\u8bc1\uff0c\u540e\u671f\u7ef4\u62a4\u6709\u636e\u53ef\u67e5<\/span>\n      <div class=\"photo-grid\">\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-ybgcys-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5b9e\u62cd<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n    <div class=\"step-card\">\n      <span class=\"step-no\">6<\/span><h4>\u7cfb\u7edf\u8c03\u8bd5\u4e0e\u4ea4\u4ed8<\/h4>\n      <p>\u7cfb\u7edf\u6ce8\u6c34\u3001\u6392\u6c14\u3001\u6253\u538b\u4fdd\u538b\uff1b\u6c34\u6e29+\u5ba4\u6e29\u53cc\u8054\u52a8\u8c03\u8bd5\uff08WiFi \u7ebf\u63a7\u5668 \/ \u66fc\u745e\u5fb7\u6e29\u63a7\uff09\uff1b\u51fa\u5177\u8fd0\u884c\u62a5\u544a\uff08\u51fa\u6c34\u6e29\u5ea6\u3001\u5ba4\u6e29\u3001\u566a\u97f3\uff09\u4e09\u65b9\u7b7e\u5b57\u3002\u73b0\u573a\u6559\u5b66\uff1a\u6a21\u5f0f\u3001\u5b9a\u65f6\u3001\u6ee4\u7f51\u6e05\u6d17\u3001\u552e\u540e\u6d41\u7a0b\u3002<\/p>\n      <span class=\"point\">\u2192 \u51fa\u98ce\u6e29\u5dee\u8fbe\u6807\u3001\u5404\u533a\u57df\u72ec\u7acb\u63a7\u6e29<\/span>\n    <\/div>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u2795 \u4e24\u7aef\u670d\u52a1\u5ef6\u4f38\uff08+2\uff09<\/h3>\n  <div class=\"card-grid\">\n    <div class=\"card\">\n      <h4>\uff0b1 \u552e\u524d\uff1a\u514d\u8d39\u52d8\u6d4b\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/h4>\n      <p>\u7b2c\u4e00\u9636\u6bb5 S1\u2013S8 \u5df2\u5b8c\u6210\u2014\u2014\u9700\u6c42\u7406\u89e3\u3001\u75db\u70b9\u8bca\u65ad\u3001\u8d1f\u8377\u6d4b\u7b97\u3001\u8bbe\u5907\u9009\u578b\u4e0e\u914d\u7f6e\u603b\u89c8\uff0c\u662f\u65bd\u5de5\u7cbe\u51c6\u843d\u5730\u7684\u524d\u63d0\u3002<\/p>\n      <div class=\"photo-grid\">\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-elktbjt-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u514d\u8d39\u52d8\u6d4b\u65b9\u6848\u8bbe\u8ba1-\u4e8c\u697c\u7a7a\u8c03\u5e03\u5c40\u56fe\" loading=\"lazy\"><figcaption>\u4e8c\u697c\u7a7a\u8c03\u5e03\u5c40\u56fe<\/figcaption><\/figure>\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-elxfbjt-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u514d\u8d39\u52d8\u6d4b\u65b9\u6848\u8bbe\u8ba1-\u4e8c\u697c\u65b0\u98ce\u5e03\u5c40\u56fe\" loading=\"lazy\"><figcaption>\u4e8c\u697c\u65b0\u98ce\u5e03\u5c40\u56fe<\/figcaption><\/figure>\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-slktbjt-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u514d\u8d39\u52d8\u6d4b\u65b9\u6848\u8bbe\u8ba1-\u4e09\u697c\u7a7a\u8c03\u5e03\u5c40\u56fe\" loading=\"lazy\"><figcaption>\u4e09\u697c\u7a7a\u8c03\u5e03\u5c40\u56fe<\/figcaption><\/figure>\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-slxfbjt-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u514d\u8d39\u52d8\u6d4b\u65b9\u6848\u8bbe\u8ba1-\u4e09\u697c\u65b0\u98ce\u5e03\u5c40\u56fe\" loading=\"lazy\"><figcaption>\u4e09\u697c\u65b0\u98ce\u5e03\u5c40\u56fe<\/figcaption><\/figure>\n        <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sldnbjt-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u514d\u8d39\u52d8\u6d4b\u65b9\u6848\u8bbe\u8ba1-\u4e09\u697c\u5730\u6696\u5e03\u5c40\u56fe\" loading=\"lazy\"><figcaption>\u4e09\u697c\u5730\u6696\u5e03\u5c40\u56fe<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n    <div class=\"card\">\n      <h4>\uff0b2 \u552e\u540e\uff1a10 \u5e74\u80fd\u8017\u8ddf\u8e2a\u4e0e\u56de\u8bbf<\/h4>\n      <p>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\u3002\u7cfb\u7edf\u8fd0\u884c\u540e\u6301\u7eed\u8ddf\u8e2a\u80fd\u8017\u3001\u5e74\u5ea6\u56de\u8bbf\u3001\u63d0\u4f9b\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae\uff0c\u8ba9\u5ba2\u6237\u300c\u7528\u5f97\u8d77\u3001\u7528\u5f97\u660e\u767d\u300d\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 11. \u5173\u952e\u5de5\u827a\u8282\u70b9\u4e0e\u9a8c\u6536\u6807\u51c6 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s11\">\n  <h2 class=\"section-title\"><span class=\"num\">11<\/span>\u5173\u952e\u5de5\u827a\u8282\u70b9\u4e0e\u9a8c\u6536\u6807\u51c6<span class=\"sub\">\u8d28\u91cf\u786c\u6307\u6807<\/span><\/h2>\n\n  <h3 class=\"sub-title\">11.1 \u7a7a\u8c03\u6c34\u7ba1\u7cfb\u7edf\uff08\u6c34\u7cfb\u7edf\u8f93\u914d\uff09<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:160px\">\u5de5\u827a\u8282\u70b9<\/th><th>\u9a8c\u6536\u6807\u51c6<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8fde\u63a5\u65b9\u5f0f<\/td><td>PPR \u7ba1\u70ed\u7194\u8fde\u63a5\uff0c\u65e0\u660e\u706b\uff0c\u63a5\u5934\u65e0\u865a\u710a\u3001\u65e0\u7f29\u5f84<\/td><\/tr>\n        <tr><td>\u4e3b\u7ba1\u89c4\u683c<\/td><td>DN32\uff0832-20 \u8282\u80fd\u7cfb\u7edf\uff09\uff0c\u7981 De25 \u4f4e\u6e29\u4e3b\u7ba1<\/td><\/tr>\n        <tr><td>\u51b7\u51dd\u6c34\u7ba1<\/td><td>\u5761\u5ea6 \u22651%\uff08\u6bcf\u7c73 1cm\uff09\uff0c\u6ee1\u6c34\u6392\u6c34\u8bd5\u9a8c\u901a\u7545\uff0c\u7981\u63a5\u6c61\u6c34\u7ba1<\/td><\/tr>\n        <tr><td>\u4fdd\u6e29<\/td><td>\u6a61\u5851\u4fdd\u6e29\u5957\u8fde\u7eed\u65e0\u65ad\u70b9\uff0c\u9632\u7ed3\u9732\uff1b\u5916\u673a\u72ec\u7acb\u56de\u8def + \u5408\u9002\u7a7a\u5f00<\/td><\/tr>\n        <tr><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u6b63\u786e\u8bbe\u7f6e\uff0c\u90e8\u5206\u672b\u7aef\u5173\u95ed\u65f6\u4fdd\u62a4\u6c34\u6cf5\u3001\u5e73\u8861\u7cfb\u7edf\u6c34\u529b<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">11.2 \u5730\u6696\u7cfb\u7edf<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:160px\">\u5de5\u827a\u8282\u70b9<\/th><th>\u9a8c\u6536\u6807\u51c6<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u76d8\u7ba1\u6750\u6599<\/td><td>PERT dn20\u00d7en2.0 \u963b\u6c27\u76d8\u7ba1\uff0c\u8bbe\u8ba1\u5bff\u547d 50 \u5e74+<\/td><\/tr>\n        <tr><td>\u6577\u8bbe\u5de5\u827a<\/td><td>\u5927\u5f27\u5f2f\u3001\u95f4\u8ddd\u5747\u5300\uff0c\u6324\u5851\u677f + \u53cd\u5c04\u819c\u57ab\u5c42\u5e73\u6574<\/td><\/tr>\n        <tr><td>\u4fdd\u538b\u6307\u6807<\/td><td>0.6\u20130.8MPa \/ \u7a33\u538b \u22651h\uff0c\u538b\u964d \u22640.02MPa \u5408\u683c<\/td><\/tr>\n        <tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>14 \u56de\u8def\uff0c\u5404\u533a\u57df\u72ec\u7acb\u63a7\u5236\uff0c\u6c34\u529b\u5e73\u8861\u7cbe\u51c6<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">11.3 \u65b0\u98ce\u7cfb\u7edf<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:160px\">\u5de5\u827a\u8282\u70b9<\/th><th>\u9a8c\u6536\u6807\u51c6<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u7ba1\u9053\u5bc6\u5c01<\/td><td>\u7ba1\u9053\u8fde\u63a5\u4e25\u5bc6\u65e0\u6f0f\u98ce\uff0c\u4fdd\u6e29\u5230\u4f4d\u9632\u51dd\u9732<\/td><\/tr>\n        <tr><td>\u98ce\u91cf\u6d4b\u8bd5<\/td><td>\u5b9e\u6d4b\u65b0\u98ce\u91cf \u2265129m\u00b3\/h\uff08\u9700\u6c42\uff09\uff0c\u989d\u5b9a 250m\u00b3\/h \u53ef\u8c03<\/td><\/tr>\n        <tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td>\u6700\u4f4e\u6863 23.5dB(A)\uff0c\u4f4e\u4e8e\u6b63\u5e38\u7761\u7720\u73af\u5883 30dB(A)<\/td><\/tr>\n        <tr><td>\u6c14\u6d41\u7ec4\u7ec7<\/td><td>\u6bcf\u5367\u5ba4\u72ec\u7acb\u9001\/\u6392\u98ce\u53e3\uff0c\u5b9a\u5411\u6c14\u6d41\u65e0\u77ed\u6d41\u3001\u65e0\u6b7b\u89d2<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 class=\"sub-title\">11.4 \u8c03\u8bd5\u9a8c\u6536\u786c\u6307\u6807<\/h3>\n  <div class=\"table-wrap\">\n    <table>\n      <thead><tr><th style=\"width:180px\">\u6307\u6807<\/th><th>\u76ee\u6807\u503c<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u7cfb\u7edf\u6392\u6c14<\/td><td>\u5145\u5206\u3001\u65e0\u6c14\u963b<\/td><td>\u6ce8\u6c34\u540e\u9010\u8def\u6392\u6c14\uff0c\u4fdd\u969c\u6c34\u5faa\u73af<\/td><\/tr>\n        <tr><td>\u51fa\u6c34\u6e29\u5ea6<\/td><td>\u5236\u51b7 7\u2103 \/ \u5236\u70ed 45\u2103<\/td><td>\u4e24\u8054\u4f9b\u5178\u578b\u5de5\u51b5\uff0c\u6309\u8d1f\u8377\u52a8\u6001\u8c03\u8282<\/td><\/tr>\n        <tr><td>\u5ba4\u6e29\u8fbe\u6807<\/td><td>\u5404\u533a\u57df\u6309\u8bbe\u5b9a \u00b10.5\u2103<\/td><td>WiFi \u7ebf\u63a7\u5668 \/ \u66fc\u745e\u5fb7\u6e29\u63a7\u72ec\u7acb\u8c03\u6e29<\/td><\/tr>\n        <tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td>\u5185\u673a \u226435dB(A) \/ \u5916\u673a \u226455dB(A)<\/td><td>\u53c2\u7167\u5382\u5bb6\u89c4\u8303\u4e0e\u73b0\u573a\u5b9e\u6d4b<\/td><\/tr>\n        <tr><td>\u8fd0\u884c\u62a5\u544a<\/td><td>\u4e09\u65b9\u7b7e\u5b57<\/td><td>\u51fa\u6c34\u6e29\u5ea6\u3001\u5ba4\u6e29\u3001\u566a\u97f3\u6570\u636e\u5f52\u6863<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 12. \u65bd\u5de5\u5b9e\u62cd\u56fe\u96c6\uff08\u5b9e\u666f\u7559\u6863\uff09 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s12\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">12<\/span>\u65bd\u5de5\u5b9e\u62cd\u56fe\u96c6<span class=\"sub\">\u5b9e\u666f\u7559\u6863<\/span><\/h2>\n  <p style=\"font-size:15px;color:#555;margin-bottom:6px;\">\u65bd\u5de5\u5168\u8fc7\u7a0b\u6309\u300c\u5916\u673a\u4e3b\u7ba1 \/ \u5ba4\u5185\u7ba1\u8def \/ \u5730\u6696\u76d8\u7ba1 \/ \u7ebf\u63a7\u5668\u7ec6\u8282 \/ \u65b0\u98ce\u5b89\u88c5\u300d\u4e94\u7ec4\u7559\u6863\uff0c\u6bcf\u7ec4 2\u20133 \u5f20\uff0c\u5f62\u6210\u53ef\u8ffd\u6eaf\u7684\u89c6\u89c9\u6863\u6848\u3002<\/p>\n\n  <div class=\"photo-note\">\n    \ud83d\udcf7 <b>\u5b9e\u666f\u7559\u6863<\/b>\uff1a\u4e0b\u65b9\u300c\u6750\u6599\u8fdb\u573a\u9a8c\u6536 \/ \u7a7a\u8c03\u6c34\u7ba1\u94fa\u8bbe \/ \u7cfb\u7edf\u8c03\u8bd5\u4e0e\u4ea4\u4ed8\u300d\u4e09\u7ec4\u5df2\u9644\u672c\u6848\u5b9e\u62cd\u56fe\uff08\u4e0e S10 \u7cbe\u5de5\u516d\u6b65\u6cd5\u5bf9\u5e94\u6b65\u9aa4\u4e00\u81f4\uff09\uff1b\u5176\u4f59\u5206\u7ec4\uff08\u5916\u673a\u4e3b\u7ba1\u3001\u5730\u6696\u76d8\u7ba1\u3001\u7ebf\u63a7\u5668\u3001\u65b0\u98ce\uff09\u4e3a\u9884\u7559\u56fe\u4f4d\uff0c\u5c06\u4e2d\u7cae\u745e\u5e9c\u5b9e\u62cd\u56fe\u4f20\u81f3\u5a92\u4f53\u5e93\u83b7\u53d6 URL \u540e\uff0c\u66ff\u6362\u5bf9\u5e94 <code>&lt;img src&gt;<\/code> \u5373\u53ef\u3002\u547d\u540d\u793a\u4f8b\u5df2\u5217\u5728\u6bcf\u5f20\u56fe\u4f4d\u4e0b\u65b9\u3002\n  <\/div>\n\n  <h3 class=\"sub-title\">\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/h3>\n  <div class=\"photo-grid\">\n    <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u8bbe\u5907\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u6750\u6599\u8fdb\u573a\u9a8c\u6536 \u00b7 \u8bbe\u5907<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-cljc-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u6750\u6599\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u6750\u6599\u8fdb\u573a\u9a8c\u6536 \u00b7 \u7ba1\u6750<\/figcaption><\/figure>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u5916\u673a\u4e0e\u4e3b\u7ba1\u8d70\u7ba1<\/h3>\n  <div class=\"photo-grid\">\n    <div class=\"photo-place\"><span class=\"ph-group\">\u5916\u673a\u4e3b\u7ba1 \u00b7 01<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-ras252-wj-01.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u5916\u673a\u4e3b\u7ba1 \u00b7 02<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-ras252-wj-02.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u6392\u6c14\u9600 \/ \u51cf\u9707<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-ras252-wj-03.jpg<\/span><\/div>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u5ba4\u5185\u6c34\u7ba1\u94fa\u8bbe\uff08PPR \u70ed\u7194\uff09<\/h3>\n  <div class=\"photo-grid\">\n    <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-glaz-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03PPR\u6c34\u7ba1\u94fa\u8bbe\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u7a7a\u8c03\u6c34\u7ba1\u94fa\u8bbe\uff08PPR \u70ed\u7194\uff09<\/figcaption><\/figure>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u5ba4\u5185\u7ba1\u8def \u00b7 02<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-sn-pipeline-02.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u4fdd\u6e29 \/ \u56fa\u5b9a<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-sn-baowen-01.jpg<\/span><\/div>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536<\/h3>\n  <div class=\"photo-grid\">\n    <figure><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-ybgcys-01.jpg\" alt=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u5170\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5b9e\u62cd<\/figcaption><\/figure>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u5730\u6696\u76d8\u7ba1<\/h3>\n  <div class=\"photo-grid\">\n    <div class=\"photo-place\"><span class=\"ph-group\">\u76d8\u7ba1\u6577\u8bbe \u00b7 01<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-dn-panguan-01.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u5206\u96c6\u6c34\u5668<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-dn-fenjishui-01.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u76d8\u7ba1\u6577\u8bbe \u00b7 02<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-dn-panguan-02.jpg<\/span><\/div>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u7ebf\u63a7\u5668 \/ \u7ec6\u8282<\/h3>\n  <div class=\"photo-grid\">\n    <div class=\"photo-place\"><span class=\"ph-group\">\u7ebf\u63a7\u5668\u9884\u7559<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-xkq-yuliu-01.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u6210\u54c1\u4fdd\u62a4<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-chengpin-baohu-01.jpg<\/span><\/div>\n  <\/div>\n\n  <h3 class=\"sub-title\">\u65b0\u98ce\u5b89\u88c5<\/h3>\n  <div class=\"photo-grid\">\n    <div class=\"photo-place\"><span class=\"ph-group\">\u65b0\u98ce\u673a\u4e3b\u673a<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-xf-host-01.jpg<\/span><\/div>\n    <div class=\"photo-place\"><span class=\"ph-group\">\u9001 \/ \u6392\u98ce\u53e3<\/span><span class=\"ph-hint\">\u5b9e\u666f\u56fe\u5f85\u8865\u5145<\/span><span class=\"ph-name\">zlrfxi-tsds-xf-koutou-01.jpg<\/span><\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- 13. \u7cfb\u7edf\u9a8c\u8bc1\u4e0e\u6548\u679c\u4ea4\u4ed8 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"s13\">\n  <h2 class=\"section-title\"><span class=\"num\">13<\/span>\u7cfb\u7edf\u9a8c\u8bc1\u4e0e\u6548\u679c\u4ea4\u4ed8<span class=\"sub\">\u8fd0\u884c\u62a5\u544a<\/span><\/h2>\n\n  <h3 class=\"sub-title\">13.1 \u8c03\u8bd5\u8fd0\u884c\u6570\u636e\uff08\u6548\u679c\u5b9e\u6d4b\uff09<\/h3>\n  <div class=\"verify-grid\">\n    <div class=\"verify-card\"><div class=\"v-num\">7\u2103 \/ 45\u2103<\/div><div class=\"v-label\">\u5236\u51b7 \/ \u5236\u70ed\u51fa\u6c34\u6e29\u5ea6<\/div><\/div>\n    <div class=\"verify-card\"><div class=\"v-num\">\u00b10.5\u2103<\/div><div class=\"v-label\">\u5404\u533a\u57df\u5ba4\u6e29\u8fbe\u6807\u504f\u5dee<\/div><\/div>\n    <div class=\"verify-card\"><div class=\"v-num\">\u226435dB(A)<\/div><div class=\"v-label\">\u5185\u673a\u8fd0\u884c\u566a\u97f3<\/div><\/div>\n    <div class=\"verify-card\"><div class=\"v-num\">\u226455dB(A)<\/div><div class=\"v-label\">\u5916\u673a\u8fd0\u884c\u566a\u97f3<\/div><\/div>\n    <div class=\"verify-card\"><div class=\"v-num\">23.5dB(A)<\/div><div class=\"v-label\">\u65b0\u98ce\u6700\u4f4e\u6863\u566a\u97f3<\/div><\/div>\n  <\/div>\n  <p style=\"font-size:13px;color:#888;\">* \u4ee5\u4e0a\u4e3a\u6309\u5382\u5bb6\u89c4\u8303\u4e0e\u73b0\u573a\u8c03\u8bd5\u7684\u5178\u578b\u76ee\u6807\u503c\uff0c\u6700\u7ec8\u4ee5\u4e09\u65b9\u7b7e\u5b57\u7684\u300a\u7cfb\u7edf\u8fd0\u884c\u62a5\u544a\u300b\u5b9e\u6d4b\u6570\u636e\u4e3a\u51c6\u3002<\/p>\n\n  <h3 class=\"sub-title\">13.2 \u80fd\u8017\u9a8c\u8bc1\uff08\u540c\u6237\u578b\u6d4b\u7b97\uff09<\/h3>\n  <div class=\"value-box\" style=\"background:#fff8f0;border:1px solid #ffe0b2;\">\n    <p style=\"font-size:14px;color:#555;\">\u6309\u672c\u6848\u8bbe\u8ba1\u53c2\u6570\u6d4b\u7b97\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a\u5236\u70ed COP \u8fbe 2.72\uff08\u221212\u2103\/35\u2103\uff09\uff0c1 \u5ea6\u7535\u53ef\u642c\u8fd0\u8fd1 3 \u500d\u70ed\u91cf\uff1b\u53e0\u52a0 32-20 \u8282\u80fd\u7cfb\u7edf\uff0c\u51ac\u5b63\u91c7\u6696\u8d39\u7528\u8f83\u4f20\u7edf\u71c3\u6c14\u58c1\u6302\u7089<strong style=\"color:#c83c3c;\">\u8282\u7701\u7ea6 40~50%<\/strong>\uff1b\u518d\u53e0\u52a0 WiFi \u5ba4\u6e29\u8054\u52a8\uff08\u8fbe\u6807\u5373\u8c03\uff09\uff0c\u6bcf\u6708\u9884\u8ba1\u518d\u7701 <strong style=\"color:#c83c3c;\">10~25%<\/strong> \u80fd\u8017\u3002\u4ea4\u4ed8\u540e\u8fdb\u5165\u300c10 \u5e74\u80fd\u8017\u8ddf\u8e2a\u300d\uff0c\u4ee5\u672c\u5c0f\u533a\u5b9e\u6d4b\u6570\u636e\u6301\u7eed\u6821\u51c6\u3002<\/p>\n  <\/div>\n\n  <h3 class=\"sub-title\">13.3 \u5ba2\u6237\u53cd\u9988<\/h3>\n  <div class=\"quote\">\n    \u300c\u4e09\u5c42\u623f\u5b50\u6700\u6015\u51ac\u5929\u51b7\u70ed\u4e0d\u5747\u3001\u590f\u5929\u4e09\u697c\u95f7\uff0c\u88c5\u5b8c\u4e4b\u540e\u5404\u5c42\u80fd\u72ec\u7acb\u63a7\u6e29\uff0c\u4e8c\u697c\u5367\u5ba4\u65b0\u98ce\u5b89\u9759\uff0c\u591c\u91cc\u7761\u5f97\u8e0f\u5b9e\u3002\u300d\n    <span class=\"q-by\">\u2014 \u4e1a\u4e3b\u5170\u8001\u5e08\uff08\u53e3\u8ff0\u6574\u7406\uff0c\u5f85\u8865\u5145\u6b63\u5f0f\u8bc4\u4ef7\uff09<\/span>\n  <\/div>\n\n  <h3 class=\"sub-title\">13.4 \u4e09\u65b9\u4ef7\u503c\u4e0e\u8fed\u4ee3<\/h3>\n  <div class=\"card-grid\">\n    <div class=\"card\">\n      <h4>\ud83c\udfe0 \u4e1a\u4e3b\u8d62<\/h4>\n      <p>\u5206\u5c42\u72ec\u7acb\u7cbe\u51c6\u63a7\u6e29\uff0c\u4e8c\u697c\u6d01\u51c0\u65b0\u98ce\uff0c\u957f\u671f\u8fd0\u884c\u8d39\u7528\u53ef\u63a7\u2014\u2014\u300c\u7528\u5f97\u8d77\u3001\u7528\u5f97\u8212\u670d\u300d\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udd27 \u9f99\u8109\u8d62<\/h4>\n      <p>\u300c\u5ba2\u9910\u5385\u5206\u673a+\u897f\u6652\u8865\u507f+PE\u51c0\u5316\u300d\u5f0f\u7684\u6807\u51c6\u5316\u903b\u8f91\u6c89\u6dc0\u8fdb\u65bd\u5de5 SOP\uff0c\u53ef\u8fc1\u79fb\u5230\u66f4\u591a\u4e09\u5c42\u4f4f\u5b85\u540c\u7c7b\u9879\u76ee\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <h4>\ud83d\udc64 \u4f7f\u7528\u8005\u8d62<\/h4>\n      <p>\u8001\u4eba\u4e0e\u5b69\u5b50\u5728\u4e09\u697c\u8336\u5ba4\u3001\u4e8c\u697c\u5367\u5ba4\u5747\u80fd\u83b7\u5f97\u7a33\u5b9a\u6e29\u5ea6\u4e0e\u5065\u5eb7\u7a7a\u6c14\uff0c\u5c45\u4f4f\u54c1\u8d28\u5b9e\u6253\u5b9e\u63d0\u5347\u3002<\/p>\n    <\/div>\n  <\/div>\n  <div class=\"cta-line\">\n    <p>\u672c\u6863\u6848\u4e3a\u300c\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u300d\u5ba2\u6237\u5168\u8fc7\u7a0b\u7559\u6863\u7b2c\u4e8c\u9636\u6bb5 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/p>\n    <p>\u514d\u8d39\u52d8\u6d4b \/ \u65b9\u6848\u8bbe\u8ba1 \/ \u7cbe\u5de5\u4ea4\u4ed8\uff0c\u5357\u5bcc\u68ee\u5e97 028-86131795 \uff5c \u5317\u5bcc\u68ee\u5e97 028-65272586<\/p>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- FAQ -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"faq\" style=\"background:#fff;border-radius:8px;padding:30px 0;\">\n  <h2 class=\"section-title\"><span class=\"num\">\u2753<\/span>\u65bd\u5de5\u4ea4\u4ed8\u5e38\u89c1\u95ee\u9898<\/h2>\n\n  <details class=\"faq-item\">\n    <summary>\u4e24\u8054\u4f9b\u65bd\u5de5\u5468\u671f\u5927\u6982\u591a\u957f\uff1f<\/summary>\n    <div class=\"faq-a\">\u4e09\u5c42\u72ec\u7acb\u4f4f\u5b85\u542b\u7a7a\u8c03\u6c34\u7ba1\u3001\u5730\u6696\u76d8\u7ba1\u3001\u65b0\u98ce\u4e09\u90e8\u5206\uff0c\u5206\u4e24\u671f\u63a8\u8fdb\uff1a\u4e00\u671f\u9690\u853d\u5de5\u7a0b\uff08\u6c34\u7ba1+\u76d8\u7ba1+\u4fdd\u538b+\u9a8c\u6536\uff09\u7ea6 2\u20133 \u5468\uff0c\u4e8c\u671f\u660e\u88c5\u4e0e\u8c03\u8bd5\u5728\u540a\u9876\u5c01\u677f\u540e\u3001\u88c5\u4fee\u5c3e\u58f0\u8fdb\u884c\uff0c\u7ea6 1 \u5468\u3002\u5177\u4f53\u968f\u88c5\u4fee\u8fdb\u5ea6\u4e0e\u73b0\u573a\u6761\u4ef6\u6d6e\u52a8\u3002<\/div>\n  <\/details>\n  <details class=\"faq-item\">\n    <summary>\u5730\u6696\u76d8\u7ba1\u4fdd\u538b\u8981\u4fdd\u591a\u4e45\uff1f\u6807\u51c6\u662f\u4ec0\u4e48\uff1f<\/summary>\n    <div class=\"faq-a\">PERT \u76d8\u7ba1\u6577\u8bbe\u540e\u6ce8\u6c34\u4fdd\u538b 0.6\u20130.8MPa\uff0c\u7a33\u538b \u22651h\uff0c\u538b\u964d \u22640.02MPa \u4e3a\u5408\u683c\u3002\u4fdd\u538b\u8d2f\u7a7f\u88c5\u4fee\u5168\u7a0b\uff08\u5e26\u538b\u65bd\u5de5\uff09\uff0c\u76f4\u81f3\u56de\u586b\u4e0e\u9762\u5c42\u5b8c\u6210\uff0c\u786e\u4fdd\u76d8\u7ba1\u65e0\u635f\u4f24\u3001\u65e0\u6e17\u6f0f\u540e\u518d\u5c01\u95ed\u3002<\/div>\n  <\/details>\n  <details class=\"faq-item\">\n    <summary>\u4e3a\u4ec0\u4e48\u4e24\u8054\u4f9b\u6c34\u7ba1\u7528 PPR \u70ed\u7194\uff0c\u800c\u4e0d\u662f\u710a\u63a5\uff1f<\/summary>\n    <div class=\"faq-a\">\u4e24\u8054\u4f9b\u6c34\u7cfb\u7edf\u4ee5\u6c34\u7ba1\u8f93\u914d\u51b7\u70ed\u6c34\uff0cPPR \u70ed\u7194\u8fde\u63a5\u65e0\u660e\u706b\u3001\u63a5\u5934\u53ef\u9760\u3001\u8010\u8150\u8680\uff0c\u662f\u6c34\u7cfb\u7edf\u6807\u51c6\u5de5\u827a\uff1b\u4e0e\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u7684\u300c\u5145\u6c2e\u710a\u63a5\u94dc\u7ba1\u300d\u4e0d\u540c\u3002\u70ed\u7194\u63a5\u53e3\u8fde\u7eed\u4fdd\u6e29\u3001\u9632\u7ed3\u9732\uff0c\u66f4\u9002\u5408\u591a\u5c42\u4f4f\u5b85\u8fdc\u8ddd\u79bb\u8f93\u914d\u3002<\/div>\n  <\/details>\n  <details class=\"faq-item\">\n    <summary>\u4ea4\u4ed8\u540e\u600e\u4e48\u9a8c\u6536\u6548\u679c\u662f\u5426\u8fbe\u6807\uff1f<\/summary>\n    <div class=\"faq-a\">\u8c03\u8bd5\u9636\u6bb5\u51fa\u5177\u300a\u7cfb\u7edf\u8fd0\u884c\u62a5\u544a\u300b\uff1a\u8bb0\u5f55\u51fa\u6c34\u6e29\u5ea6\uff08\u5236\u51b7 7\u2103\/\u5236\u70ed 45\u2103\uff09\u3001\u5404\u533a\u57df\u5ba4\u6e29\uff08\u6309\u8bbe\u5b9a \u00b10.5\u2103\uff09\u3001\u5185\u673a\/\u5916\u673a\u566a\u97f3\uff08\u226435\/\u226455dB(A)\uff09\uff0c\u7531\u4e1a\u4e3b\u3001\u88c5\u4fee\u65b9\u3001\u65bd\u5de5\u65b9\u4e09\u65b9\u7b7e\u5b57\u3002\u4e1a\u4e3b\u53ef\u73b0\u573a\u611f\u77e5\u5404\u533a\u57df\u72ec\u7acb\u63a7\u6e29\u6548\u679c\u3002<\/div>\n  <\/details>\n  <details class=\"faq-item\">\n    <summary>\u552e\u540e\u8d28\u4fdd\u600e\u4e48\u7b97\uff1f\u9690\u853d\u5de5\u7a0b\u770b\u4e0d\u89c1\u4e86\u600e\u4e48\u529e\uff1f<\/summary>\n    <div class=\"faq-a\">\u8bbe\u5907\u6309\u5382\u5bb6\u8d28\u4fdd\uff08\u5982\u65e5\u7acb\u4e3b\u673a 5 \u5e74\uff09\uff0c\u7cfb\u7edf\u65bd\u5de5\u8d28\u4fdd 2 \u5e74\uff0c\u7ec8\u8eab\u7ef4\u62a4\u3001\u540c\u57ce 24h \u54cd\u5e94\u3002\u9690\u853d\u524d\u5df2\u4e09\u65b9\u9a8c\u6536\u5e76\u62cd\u7167\u7559\u6863\uff0c\u540e\u671f\u7ef4\u62a4\u6709\u636e\u53ef\u67e5\uff1b\u8fdb\u5165\u300c10 \u5e74\u80fd\u8017\u8ddf\u8e2a\u300d\u6301\u7eed\u62a4\u822a\u3002<\/div>\n  <\/details>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- \u77e5\u8bc6\u5ef6\u4f38 -->\n<!-- ============================================================ -->\n<section class=\"section\" id=\"links\">\n  <h2 class=\"section-title\"><span class=\"num\">\ud83d\udcda<\/span>\u77e5\u8bc6\u5ef6\u4f38 \u00b7 \u76f8\u5173\u9605\u8bfb<\/h2>\n  <p style=\"font-size:14px;color:#555;margin-bottom:10px;\">\u4e86\u89e3\u66f4\u591a\u7cfb\u7edf\u539f\u7406\u4e0e\u9009\u578b\u4f9d\u636e\uff0c\u53ef\u5ef6\u4f38\u9605\u8bfb\u4ee5\u4e0b\u77e5\u8bc6\u5e93\uff1a<\/p>\n  <div class=\"link-grid\">\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=916\"><b>\u4e2d\u592e\u7a7a\u8c03\u77e5\u8bc6\u5e95\u5ea7<\/b><span>\u591a\u8054\u673a \/ \u98ce\u7ba1\u673a\u9009\u578b\u4e0e\u539f\u7406<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\"><b>\u5730\u6696\u77e5\u8bc6\u5e95\u5ea7<\/b><span>\u76d8\u7ba1 \/ \u5206\u96c6\u6c34\u5668 \/ \u8282\u80fd\u7cfb\u7edf<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\"><b>\u65b0\u98ce\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7<\/b><span>\u98ce\u91cf\u8ba1\u7b97 \/ \u6c14\u6d41\u7ec4\u7ec7 \/ \u9759\u97f3<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/water-system-whitepaper.html\"><b>\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u767d\u76ae\u4e66<\/b><span>\u5929\u6c34\u5730\u6c34\u6280\u672f\u539f\u7406<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/knowledge\/solution\/two-in-one.html\"><b>\u4e24\u8054\u4f9b\u00b7\u4e94\u6052\u89e3\u51b3\u65b9\u6848<\/b><span>\u51b7\u6696\u4e00\u4f53\u5316\u8bbe\u8ba1\u601d\u8def<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/guide\/ac-20year.html\"><b>20 \u5e74\u6295\u5165\u5bf9\u6bd4<\/b><span>\u4e24\u8054\u4f9b\u5168\u751f\u547d\u5468\u671f\u6210\u672c<\/span><\/a>\n  <\/div>\n<\/section>\n\n<\/div>\n\n<footer class=\"footer\">\n  \u00a92004-2026 \u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5168\u6d41\u7a0b\u53ef\u89c6\u5316<br>\n  \u5357\u5bcc\u68ee\u5e97\uff1a028-86131795 \uff5c \u5317\u5bcc\u68ee\u5e97\uff1a028-65272586\n<\/footer>\n\n<\/div>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\" style=\"font-size:28px\"><strong>\u7b2c\u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u548c\u4f18\u5316\u8fed\u4ee3<\/strong><\/p>\n\n<figure class=\"wp-block-table aligncenter\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u65e5\u671f<\/td><td>\u670d\u52a1\u7c7b\u578b<\/td><td>\u670d\u52a1\u5185\u5bb9<\/td><td>\u670d\u52a1\u4eba\u5458<\/td><td>\u5ba2\u6237\u786e\u8ba4<\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color has-medium-font-size wp-elements-4 wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6863\u6848\u7f16\u53f7\uff1azlrfxi-tsds-lls [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6786","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u4f4f\u5b85\u91c7\u7528\u65e5\u7acb\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\uff0c\u5b9e\u73b0187.55\u33a1\u7a7a\u8c03\u4e0e198.55\u33a1\u5730\u6696\u5206\u5c42\u72ec\u7acb\u63a7\u6e29\uff0c\u8282\u80fd\u7a33\u5b9a\u8212\u9002\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u5168\u6d41\u7a0b\u6863\u6848\u53ca10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=6786\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u4f4f\u5b85\u91c7\u7528\u65e5\u7acb\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\uff0c\u5b9e\u73b0187.55\u33a1\u7a7a\u8c03\u4e0e198.55\u33a1\u5730\u6696\u5206\u5c42\u72ec\u7acb\u63a7\u6e29\uff0c\u8282\u80fd\u7a33\u5b9a\u8212\u9002\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u5168\u6d41\u7a0b\u6863\u6848\u53ca10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=6786\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-24T13:40:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786\",\"name\":\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/cdswhq-zlrfxy-lls-sbjc-01.jpg\",\"datePublished\":\"2026-07-24T13:25:01+00:00\",\"dateModified\":\"2026-07-24T13:40:22+00:00\",\"description\":\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u4f4f\u5b85\u91c7\u7528\u65e5\u7acb\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\uff0c\u5b9e\u73b0187.55\u33a1\u7a7a\u8c03\u4e0e198.55\u33a1\u5730\u6696\u5206\u5c42\u72ec\u7acb\u63a7\u6e29\uff0c\u8282\u80fd\u7a33\u5b9a\u8212\u9002\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u5168\u6d41\u7a0b\u6863\u6848\u53ca10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/cdswhq-zlrfxy-lls-sbjc-01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/cdswhq-zlrfxy-lls-sbjc-01.jpg\",\"width\":960,\"height\":1280},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6786#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","description":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u4f4f\u5b85\u91c7\u7528\u65e5\u7acb\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\uff0c\u5b9e\u73b0187.55\u33a1\u7a7a\u8c03\u4e0e198.55\u33a1\u5730\u6696\u5206\u5c42\u72ec\u7acb\u63a7\u6e29\uff0c\u8282\u80fd\u7a33\u5b9a\u8212\u9002\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u5168\u6d41\u7a0b\u6863\u6848\u53ca10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=6786","og_locale":"zh_CN","og_type":"article","og_title":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u4f4f\u5b85\u91c7\u7528\u65e5\u7acb\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\uff0c\u5b9e\u73b0187.55\u33a1\u7a7a\u8c03\u4e0e198.55\u33a1\u5730\u6696\u5206\u5c42\u72ec\u7acb\u63a7\u6e29\uff0c\u8282\u80fd\u7a33\u5b9a\u8212\u9002\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u5168\u6d41\u7a0b\u6863\u6848\u53ca10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1","og_url":"https:\/\/longmai-nt.com\/?page_id=6786","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-24T13:40:22+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=6786","url":"https:\/\/longmai-nt.com\/?page_id=6786","name":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=6786#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=6786#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg","datePublished":"2026-07-24T13:25:01+00:00","dateModified":"2026-07-24T13:40:22+00:00","description":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662\u4e09\u5c42\u4f4f\u5b85\u91c7\u7528\u65e5\u7acb\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u7cfb\u7edf\uff0c\u5b9e\u73b0187.55\u33a1\u7a7a\u8c03\u4e0e198.55\u33a1\u5730\u6696\u5206\u5c42\u72ec\u7acb\u63a7\u6e29\uff0c\u8282\u80fd\u7a33\u5b9a\u8212\u9002\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u5168\u6d41\u7a0b\u6863\u6848\u53ca10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=6786#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=6786"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=6786#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/cdswhq-zlrfxy-lls-sbjc-01.jpg","width":960,"height":1280},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=6786#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e2d\u7cae\u745e\u5e9c\u73ba\u9662 \u00b7 \u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b+\u65b0\u98ce\u6863\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6786"}],"version-history":[{"count":11,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6786\/revisions"}],"predecessor-version":[{"id":8192,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6786\/revisions\/8192"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}