{"id":6814,"date":"2026-07-16T23:19:11","date_gmt":"2026-07-16T15:19:11","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=6814"},"modified":"2026-07-30T16:25:13","modified_gmt":"2026-07-30T08:25:13","slug":"%e6%88%90%e9%83%bd%e5%90%88%e9%99%a2-%c2%b7-%e7%8e%8b%e5%85%88%e7%94%9f%e5%a4%9a%e9%a1%b9%e7%9b%ae%e5%af%b9%e6%af%94%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=6814","title":{"rendered":"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848"},"content":{"rendered":"\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u6210\u90fd\u5408\u9662\u00b7\u738b\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eabvs\u5c0a\u777f\u5168\u6548 \u7a7a\u8c03\u53cc\u65b9\u6848 + \u5730\u6696\u4e09\u65b9\u6848 \u5bf9\u6bd4\u65b9\u6848\u4e66\",\n  \"author\": {\"@type\": \"Person\", \"name\": \"\u9ec4\u52c7\", \"jobTitle\": \"\u65b9\u6848\u987e\u95ee\", \"description\": \"13 \u5e74\u6696\u901a\u884c\u4e1a\u4ece\u4e1a\u7ecf\u9a8c\uff0c\u4e13\u6ce8\u522b\u5885\u4e2d\u592e\u7a7a\u8c03 \/ \u5730\u6696 \/ \u751f\u6d3b\u70ed\u6c34\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u8bbe\u8ba1\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"\u9f99\u8109\u6696\u901a\"},\n  \"datePublished\": \"2026-07-16\",\n  \"about\": \"\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u751f\u6d3b\u70ed\u6c34\u7cfb\u7edf\u96c6\u6210\u65b9\u6848\u5bf9\u6bd4\"\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\"@type\":\"Question\",\"name\":\"\u6210\u90fd\u5408\u9662\u522b\u5885\u7528\u4e00\u62d6\u4e03\u4e2d\u592e\u7a7a\u8c03\uff0c\u8d85\u914d\u7387114%\u5b89\u5168\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u65e5\u7acb\u591a\u8054\u673a\u5141\u8bb8\u8d85\u914d\u4e0a\u9650130%\uff0c\u672c\u65b9\u684822.4kW\u5916\u673a\u914d25.6kW\u5185\u673a\uff0c\u8d85\u914d\u7387114%\u5904\u4e8e\u5b89\u5168\u5408\u7406\u533a\u95f4\uff0c\u4e14\u5e38\u4f4f\u4ec52\u4eba\uff0c\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u7cfb\u7edf\u9ad8\u6548\u8fd0\u884c\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u8212\u4eab\u548c\u5c0a\u777f\u5168\u6548II\u600e\u4e48\u9009\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8212\u4eab\u5b9a\u4f4d\u7ecf\u6d4e\u5b9e\u7528\uff0c8\u6298\u540e\u521d\u6295\u66f4\u4f4e\uff1b\u5c0a\u777f\u5168\u6548II\u652f\u6301\u6e29\u6e7f\u53cc\u63a7\u4e0e\u4e09\u7ba1\u5236\u72ec\u7acb\u9664\u6e7f\uff08\u4e8c\u697c\u4e09\u697c\u914d\u7f6e\uff09\uff0c\u6210\u90fd\u9ad8\u6e7f\u73af\u5883\u4e0b\u8212\u9002\u5ea6\u4e0e\u957f\u671f\u80fd\u8017\u66f4\u4f18\uff0c\u4f46\u521d\u6295\u9ad8\u7ea6 2 \u4e07\u3002\u5165\u4f4f\u7387\u9ad8\u3001\u5bf9\u6e7f\u5ea6\u654f\u611f\u9009\u5c0a\u777f\uff0c\u9884\u7b97\u4f18\u5148\u9009\u8212\u4eab\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5730\u669699\/119\/169\u4e09\u6863\u5dee\u5728\u54ea\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"99\u4e3a\u5e02\u573a\u901a\u914d\u603b\u63a7\uff08\u4f1f\u661f\u603b\u63a7\uff09\uff0c119\u4e3a\u5e02\u573a\u901a\u914d\u5206\u63a7\uff08\u66fc\u745e\u5fb7\u5206\u63a7\uff0c\u53ef\u5206\u5c42\u63a7\u6e29\uff09\uff0c169\u4e3a\u516c\u53f8\u8282\u80fd\u8bbe\u8ba1\uff0832-20\u7ba1+\u6d41\u91cf\u63d0\u5347+WiFi\u8054\u52a8+\u4e09\u65b9\u8054\u4fdd\uff09\u3002182\u33a1\u522b\u5885\u63a8\u8350119\u5206\u63a7\u8d77\u6b65\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e3a\u4ec0\u4e48\u70ed\u6c34\u8981\u505a\u5206\u79bb\u5f0f\uff08\u5a01\u80fd+\u6797\u5185\uff09\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5730\u6696\u4e0e\u4e00\u697c\u751f\u6d3b\u70ed\u6c34\u7531\u5a01\u80fd\u51b7\u51dd\u7089\u7edf\u4e00\u4f9b\u5e94\uff1b\u4e8c\u697c\u4e09\u697c\u8ddd\u79bb\u8fdc\uff0c\u5355\u72ec\u7528\u6797\u518524L\u96f6\u51b7\u6c34\u71c3\u6c14\u70ed\u6c34\u5668\u5e76\u505a\u56de\u6c34\u7ba1\u5faa\u73af\uff0c\u4fdd\u8bc1\u8fdc\u7aef\u5373\u5f00\u5373\u70ed\uff0c\u4e24\u7cfb\u7edf\u4e92\u4e0d\u5e72\u6270\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"182\u33a1\u5730\u6696\u752824kW\u51b7\u51dd\u7089\u591f\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6309\u6210\u90fd\u522b\u5885\u5b9e\u9645\u70ed\u8d1f\u8377\u7ea6100-130W\/\u33a1\uff0c182\u33a1\u7ea618-24kW\uff0c24kW\u51b7\u51dd\u7089\u53ef\u8986\u76d6\uff1b\u914d\u5408\u4e8c\u6b21\u7cfb\u7edf\u4e0e\u5206\u533a\u63a7\u5236\u66f4\u7a33\u59a5\u3002\u6700\u7ec8\u4ee5\u73b0\u573a\u8d1f\u8377\u590d\u6838\u4e3a\u51c6\u3002\"}}\n  ]\n}\n<\/script>\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/echarts@5\/dist\/echarts.min.js\"><\/script>\n<style>\n:root{\n  --primary:#1a3a5c; --primary-light:#2d5f8a; --accent:#c0392b; --accent-light:#e74c3c;\n  --gold:#b8860b; --gold-light:#f0d080; --bg:#fafaf7; --bg-card:#fff; --bg-section:#f5f2ec;\n  --text:#2c2c2c; --text-light:#5a5a5a; --text-muted:#888; --border:#e0dcd4; --border-light:#eeeae2;\n  --success:#27ae60; --warn:#e67e22; --info:#2980b9;\n  --shadow-sm:0 1px 3px rgba(0,0,0,.06); --shadow-md:0 4px 16px rgba(0,0,0,.08);\n  --radius:8px; --radius-lg:12px;\n}\n*{box-sizing:border-box;margin:0;padding:0}\nbody{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;background:var(--bg);color:var(--text);line-height:1.7;font-size:15px}\n.wrap{max-width:1080px;margin:0 auto;background:var(--bg-card);box-shadow:var(--shadow-md)}\nheader.cover{\n  position:relative;overflow:hidden;\n  background:\n    linear-gradient(180deg, rgba(0,0,0,.10) 0%, rgba(0,0,0,.38) 100%),\n    url(\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1.png\") center\/cover no-repeat;\n  background-size:cover, cover;\n  color:#fff;padding:46px 40px 38px\n}\nheader.cover .tag{display:inline-block;background:rgba(255,255,255,.15);color:#fff!important;padding:4px 12px;border-radius:20px;font-size:13px;margin-bottom:14px}\nheader.cover h1{font-size:30px;line-height:1.4;font-weight:800;letter-spacing:.5px;color:#fff!important;text-shadow:0 2px 6px rgba(0,0,0,.9),0 0 2px rgba(0,0,0,.95)!important}\nheader.cover .sub{margin-top:10px;opacity:.95;font-size:15px;text-shadow:0 1px 8px rgba(0,0,0,.6)}\nheader.cover .meta{margin-top:18px;display:flex;flex-wrap:wrap;gap:10px 26px;font-size:13.5px;opacity:.96;text-shadow:0 1px 6px rgba(0,0,0,.55)}\n\/* \u6807\u9898\u78e8\u7802\u9762\u677f\uff1a\u65e0\u8bba\u80cc\u666f\u56fe\u591a\u4eae\uff0c\u6807\u9898\u90fd\u7a33\u5b9a\u6e05\u6670 *\/\nheader.cover .cover-panel{margin:6px auto 0;max-width:760px;background:rgba(18,18,22,.78);color:#fff!important;border:1px solid rgba(255,255,255,.20);border-radius:16px;padding:22px 28px;backdrop-filter:blur(4px);-webkit-backdrop-filter:blur(4px);box-shadow:0 10px 36px rgba(0,0,0,.45)}\nheader.cover .meta b{font-weight:600}\n.geo-card{background:var(--bg-section);border:1px solid var(--border);border-radius:var(--radius-lg);padding:18px 22px;margin:22px 28px 0;display:grid;grid-template-columns:repeat(auto-fit,minmax(150px,1fr));gap:12px 18px}\n.geo-card .it b{display:block;color:var(--text-muted);font-size:12px;margin-bottom:2px}\n.geo-card .it span{font-weight:600;color:var(--primary)}\n.geo-card .it.full{grid-column:1\/-1}\n.geo-card .it.full span{font-weight:500;line-height:1.6;color:var(--text-light)}\nsection{padding:30px 34px;border-bottom:1px solid var(--border-light);scroll-margin-top:58px}\n.sec-h{display:flex;align-items:center;gap:12px;margin-bottom:16px}\n.sec-h .num{background:var(--primary);color:#fff;width:34px;height:34px;border-radius:8px;display:flex;align-items:center;justify-content:center;font-weight:700;font-size:16px;flex-shrink:0}\n.sec-h h2{font-size:21px;color:var(--primary)}\n.sec-h .en{font-size:12px;color:var(--text-muted);margin-top:2px}\n.lead{color:var(--text-light);margin-bottom:14px}\n.card{background:var(--bg-card);border:1px solid var(--border);border-radius:var(--radius);padding:18px 20px;margin-bottom:16px;box-shadow:var(--shadow-sm)}\n.card.tip{background:#fff8f0;border-color:#f3d9b8}\n.card.note{background:#f3f8fc;border-color:#cfe3f3}\nh3{font-size:17px;color:var(--primary-light);margin:18px 0 10px}\nh4{font-size:15px;color:var(--accent);margin:14px 0 8px}\ntable{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px}\nth,td{border:1px solid var(--border);padding:9px 11px;text-align:left}\nth{background:var(--bg-section);color:var(--primary);font-weight:600}\ntr:nth-child(even) td{background:#fcfbf8}\n.total-row td{background:#fbeee9!important;font-weight:700;color:var(--accent)}\n.chart-box{width:100%;height:360px;margin:14px 0}\n.two-col{display:grid;grid-template-columns:1fr 1fr;gap:18px}\n@media(max-width:760px){.two-col{grid-template-columns:1fr}.wrap{margin:0}section{padding:24px 18px}header.cover{padding:34px 22px}header.cover h1{font-size:22px}}\n.scheme-tag{display:inline-block;padding:3px 10px;border-radius:6px;font-size:12.5px;font-weight:600;margin-bottom:6px}\n.tag-a{background:#eaf3fb;color:var(--info)}\n.tag-b{background:#fdecea;color:var(--accent)}\n.tag-f{background:#f0f7ee;color:var(--success)}\n.badge{display:inline-block;background:var(--gold);color:#fff;font-size:12px;padding:2px 9px;border-radius:12px;margin-left:6px}\n.pill{display:flex;flex-wrap:wrap;gap:10px;margin:14px 0}\n.pill .p{background:var(--bg-section);border:1px solid var(--border);border-radius:20px;padding:6px 14px;font-size:13.5px}\n.pill .p b{color:var(--primary)}\n.stars{color:var(--gold);letter-spacing:2px}\n.muted{color:var(--text-muted);font-size:13px}\n.warn-line{background:#fff4ef;border-left:4px solid var(--warn);padding:12px 16px;border-radius:0 8px 8px 0;margin:12px 0;font-size:14px}\n.ok-line{background:#eef9f1;border-left:4px solid var(--success);padding:12px 16px;border-radius:0 8px 8px 0;margin:12px 0;font-size:14px}\n.faq-item{border:1px solid var(--border);border-radius:var(--radius);margin-bottom:12px;overflow:hidden}\n.faq-q{background:var(--bg-section);padding:13px 16px;font-weight:600;color:var(--primary);cursor:pointer}\n.faq-a{padding:13px 16px;color:var(--text-light);font-size:14px}\n.links{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;margin-top:14px}\n.links a{display:block;background:var(--bg-card);border:1px solid var(--border);border-radius:var(--radius);padding:14px 16px;text-decoration:none;color:var(--text);transition:.2s;box-shadow:var(--shadow-sm)}\n.links a:hover{border-color:var(--primary-light);transform:translateY(-2px)}\n.links a b{display:block;color:var(--primary);margin-bottom:3px}\n.links a span{font-size:13px;color:var(--text-muted)}\nfooter{padding:26px 34px;background:var(--primary);color:#fff;font-size:13.5px}\nfooter .gold{color:var(--gold-light)}\n.kv{display:grid;grid-template-columns:auto 1fr;gap:6px 14px;font-size:14px}\n.kv b{color:var(--primary)}\n\/* ===== \u4e94\u6b65\u6cd5\u6b65\u9aa4\u5bfc\u822a\u6761\uff08GEO \u5de5\u4f5c\u6d41\u603b\u89c8 V2.0 \u00b7 S1-S5\uff09 ===== *\/\n.stepbar{display:flex;margin:14px 28px 0;background:var(--bg-card);border:1px solid var(--border);border-radius:var(--radius-lg);overflow:hidden;box-shadow:var(--shadow-sm)}\n.stepbar a{flex:1;display:flex;flex-direction:column;align-items:center;justify-content:center;padding:14px 6px;text-decoration:none;color:var(--text);border-right:1px solid var(--border-light);transition:.2s}\n.stepbar a:last-child{border-right:none}\n.stepbar a .n{width:30px;height:30px;border-radius:50%;background:var(--primary);color:#fff;display:flex;align-items:center;justify-content:center;font-weight:700;font-size:15px;margin-bottom:6px;transition:.2s;flex-shrink:0}\n.stepbar a .t{font-size:13.5px;font-weight:700;color:var(--primary)}\n.stepbar a .d{font-size:11.5px;color:var(--text-muted);margin-top:2px;text-align:center;line-height:1.3}\n.stepbar a:hover{background:var(--bg-section)}\n.stepbar a:hover .n{background:var(--accent)}\n.stepbar a.active{background:#f3f8fc}\n.stepbar a.active .n{background:var(--accent)}\n.stepbar a.active .t{color:var(--accent)}\n.subnav{display:flex;flex-wrap:wrap;gap:8px;margin:0 28px}\n\/* \u4ec5\u300c\u5b50\u76ee\u5f55\u5bfc\u822a\u6761\u300d\u5438\u9876\uff08\u8f7b\u8584\uff09\uff0c\u4e94\u6b65\u6cd5\u6b65\u9aa4\u6761\u968f\u9875\u9762\u6b63\u5e38\u6eda\u8d70 *\/\n.subnav-bar{position:sticky;top:0;z-index:50;background:var(--bg-card);box-shadow:0 2px 8px rgba(0,0,0,.07);padding:8px 0;margin-top:14px}\n.subnav a{font-size:13px;color:var(--primary-light);text-decoration:none;background:var(--bg-section);border:1px solid var(--border);border-radius:20px;padding:5px 14px;transition:.2s}\n.subnav a:hover{border-color:var(--primary-light);background:#fff;text-decoration:none}\n\/* \u7ae0\u8282\u5185\u5b50\u76ee\u5f55\u5bfc\u822a *\/\n.sec-nav{display:flex;flex-wrap:wrap;align-items:center;gap:8px;margin:-2px 0 20px;padding:9px 12px;background:var(--bg-section);border:1px solid var(--border-light);border-left:3px solid var(--primary-light);border-radius:8px}\n.sec-nav .sn-label{font-size:12px;color:var(--text-muted);font-weight:700;margin-right:2px}\n.sec-nav a{font-size:12.5px;color:var(--primary);text-decoration:none;background:var(--bg-card);border:1px solid var(--border);border-radius:16px;padding:4px 12px;transition:.2s;white-space:nowrap}\n.sec-nav a:hover{border-color:var(--primary);background:var(--primary);color:#fff;text-decoration:none}\nh3[id],h4[id]{scroll-margin-top:64px}\n\/* \u4ea7\u54c1\u4ecb\u7ecd\u5361\u7247 *\/\n.pcard{display:grid;grid-template-columns:140px 1fr;gap:16px;background:var(--bg-card);border:1px solid var(--border);border-radius:var(--radius-lg);padding:18px;margin-bottom:16px;box-shadow:var(--shadow-sm);transition:.2s}\n.pcard:hover{box-shadow:0 4px 14px rgba(0,0,0,.1);border-color:var(--primary-light)}\n.pcard .pimg{width:140px;height:140px;object-fit:contain;border-radius:var(--radius);background:#f8f8f6;padding:6px;border:1px solid var(--border-light)}\n.pcard .pbody{display:flex;flex-direction:column;justify-content:center}\n.pcard .pbody h4{margin:0 0 6px;font-size:15px;color:var(--primary);font-weight:700}\n.pcard .pbody .ptag{display:inline-block;background:var(--bg-section);color:var(--text-muted);font-size:11.5px;padding:2px 8px;border-radius:10px;margin-bottom:6px;width:fit-content}\n.pcard .pbody p{font-size:13.5px;color:var(--text-light);line-height:1.6;margin:0}\n.pcard .pbody .plink{margin-top:8px;font-size:13px}\n.pcard .pbody .plink a{color:var(--info);text-decoration:none;font-weight:600}\n.pcard .pbody .plink a:hover{text-decoration:underline}\n@media(max-width:600px){.pcard{grid-template-columns:1fr;text-align:center}.pcard .pimg{margin:0 auto;width:120px;height:120px}}\n@media(max-width:760px){.stepbar{flex-wrap:wrap}.stepbar a{flex:1 1 50%;border-bottom:1px solid var(--border-light)}.stepbar a:last-child,.stepbar a:nth-child(5){border-bottom:none}}\n\/* ===== \u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97\uff08\u8bc1\u4e66\/\u95e8\u5e97\u56fe\u96c6\uff09 ===== *\/\n.cert-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:14px 0}\n.cert-grid figure{margin:0;background:var(--bg-card);border:1px solid var(--border);border-radius:10px;overflow:hidden;transition:box-shadow .2s}\n.cert-grid figure:hover{box-shadow:0 4px 16px rgba(0,0,0,.08)}\n.cert-img-wrap{width:100%;aspect-ratio:3\/2;overflow:hidden;background:#f8f8f8;display:flex;align-items:center;justify-content:center}\n.cert-img-wrap img{width:100%;height:100%;object-fit:contain;padding:8px;display:block}\n.cert-grid figcaption{font-size:.78rem;color:var(--text-light);padding:8px 10px;text-align:center;font-weight:600}\n.store-grid{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:14px 0}\n.store-grid figure{margin:0;border:1px solid var(--border);border-radius:12px;overflow:hidden;background:var(--bg-card);transition:box-shadow .2s}\n.store-grid figure:hover{box-shadow:0 4px 16px rgba(0,0,0,.08)}\n.store-img-wrap{width:100%;aspect-ratio:16\/9;overflow:hidden;background:#f8f8f8}\n.store-img-wrap img{width:100%;height:100%;object-fit:cover;display:block}\n.store-grid figcaption{padding:12px 14px}\n.store-grid .store-name{font-weight:700;color:var(--text);font-size:.92rem;margin-bottom:6px}\n.store-grid .addr{font-size:.8rem;color:var(--text-muted);margin:2px 0;line-height:1.5}\n@media(max-width:560px){.cert-grid{grid-template-columns:1fr}.store-grid{grid-template-columns:1fr}}\n.cert-grid figure.img-fail .cert-img-wrap,.store-grid figure.img-fail .store-img-wrap{position:relative;min-height:130px;background:#f3f3f3}\n.cert-grid figure.img-fail img,.store-grid figure.img-fail img{display:none}\n.cert-grid figure.img-fail .cert-img-wrap::after,.store-grid figure.img-fail .store-img-wrap::after{content:\"\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d\\A\u8bf7\u7528\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\";white-space:pre;text-align:center;color:#a07878;font-size:.78rem;padding:16px;display:block}\n<\/style>\n\n<div class=\"wrap\">\n\n<header class=\"cover\">\n  <div class=\"cover-panel\">\n  <span class=\"tag\">\u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u4e2d\u5fc3 \u00b7 \u522b\u5885\u51b7\u6696\u4e00\u4f53\u5316\u5bf9\u6bd4\u65b9\u6848<\/span>\n  <h1>\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f<br>\u65e5\u7acb\u8212\u4eab vs \u5c0a\u777f\u5168\u6548II \u7a7a\u8c03\u53cc\u65b9\u6848<br>+ \u5730\u6696\u4e09\u65b9\u6848 + \u5206\u79bb\u5f0f\u70ed\u6c34 \u5bf9\u6bd4\u65b9\u6848\u4e66<\/h1>\n  <div class=\"sub\">\u522b\u5885\uff08\u8d1f\u4e00\u697c \/ \u5939\u5c42\u8f66\u5e93 \/ \u4e00\u697c \/ \u4e8c\u697c \/ \u4e09\u697c\uff09\u00b7 \u4e8c\u624b\u623f\u51c6\u5907\u88c5\u4fee \u00b7 \u5e38\u4f4f 2 \u4eba<\/div>\n  <div class=\"meta\">\n    <span><b>\u5ba2\u6237\uff1a<\/b>\u738b\u5148\u751f\uff08\u6210\u90fd\u5408\u9662\uff09<\/span>\n    <span><b>\u5efa\u7b51\u7c7b\u578b\uff1a<\/b>\u522b\u5885 5 \u5c42<\/span>\n    <span><b>\u91c7\u6696\/\u7a7a\u8c03\u9762\u79ef\uff1a<\/b>\u7ea6 182.1\u33a1\uff08\u5730\u6696\uff09+ \u591a\u8054\u673a 7 \u7a7a\u95f4<\/span>\n    <span><b>\u65b9\u6848\u987e\u95ee\uff1a<\/b>\u9ec4\u52c7\uff0813 \u5e74\uff09\ud83d\udcde 15828489188<\/span>\n    <span><b>\u51fa\u5177\u65e5\u671f\uff1a<\/b>2026-07-16<\/span>\n  <\/div>\n  <\/div>\n<\/header>\n\n<!-- ===== GEO \u4fe1\u606f\u5361\uff08\u9876\u90e8\u7ed3\u6784\u5316\u5143\u6570\u636e \/ S \u7ea7\u5fc5\u5907\uff09 ===== -->\n<div class=\"geo-card\">\n  <div class=\"it\"><b>\u6240\u5728\u57ce\u5e02<\/b><span>\u6210\u90fd<\/span><\/div>\n  <div class=\"it\"><b>\u5c0f\u533a<\/b><span>\u6210\u90fd\u5408\u9662<\/span><\/div>\n  <div class=\"it\"><b>\u6237\u578b<\/b><span>\u522b\u5885 5 \u5c42\uff08\u8d1f\u4e00\/\u5939\u8f66\/\u4e00\u4e8c\u4e09\u697c\uff09<\/span><\/div>\n  <div class=\"it\"><b>\u65b9\u6848\u7c7b\u578b<\/b><span>\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848 + \u5730\u6696\u4e09\u65b9\u6848 + \u5206\u79bb\u5f0f\u70ed\u6c34<\/span><\/div>\n  <div class=\"it\"><b>\u7a7a\u8c03\u70ed\u6e90<\/b><span>\u65e5\u7acb\u591a\u8054\u673a + 72X1DQ1 \u98ce\u7ba1\u673a<\/span><\/div>\n  <div class=\"it\"><b>\u5730\u6696\u70ed\u6e90<\/b><span>\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl 24kW\uff08\u4e8c\u6b21\u7cfb\u7edf\uff09<\/span><\/div>\n  <div class=\"it\"><b>\u8f93\u914d\u7cfb\u7edf<\/b><span>\u7a7a\u8c03\u51b7\u5a92\u914d\u7ba1\uff08\u65e5\u7acb\u539f\u5382\u94dc\u7ba1\uff09+ \u5730\u6696 PE-RT \u76d8\u7ba1 + \u66fc\u745e\u5fb7\u5206\u96c6\u6c34\u5668 + \u4e8c\u6b21\u7cfb\u7edf\u53bb\u8026\u7f50<\/span><\/div>\n  <div class=\"it\"><b>\u672b\u7aef\u5f62\u5f0f<\/b><span>\u7a7a\u8c03\u8d85\u8584\u98ce\u7ba1\u5185\u673a\uff08192mm \/ 17dB\uff09+ \u5730\u6696\u5730\u9762\u8f90\u5c04\u76d8\u7ba1 + \u6797\u5185\u96f6\u51b7\u6c34\u9f99\u5934\u82b1\u6d12<\/span><\/div>\n  <div class=\"it\"><b>\u65bd\u5de5\u65b9<\/b><span>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u5b89\u88c5\u670d\u52a1\u5546\uff08\u9ec4\u52c7\u56e2\u961f\uff09<\/span><\/div>\n  <div class=\"it\"><b>\u51fa\u5177 \/ \u987e\u95ee<\/b><span>2026-07-16 \u00b7 \u9ec4\u52c7\uff0813 \u5e74\uff09<\/span><\/div>\n  <div class=\"it full\"><b>\u4e00\u53e5\u8bdd\u6458\u8981<\/b><span>\u6210\u90fd\u5408\u9662\u522b\u5885\u6696\u901a\u5bf9\u6bd4\u65b9\u6848\uff1a\u7a7a\u8c03\u65e5\u7acb\u8212\u4eab(8\u6298) vs \u5c0a\u777f\u5168\u6548II(8.5\u6298)\u53cc\u65b9\u6848 + \u5a01\u80fd\u51b7\u51dd\u7089\u5730\u6696\u4e09\u6863(99\/119\/169\u5143\/\u33a1) + \u5a01\u80fd\/\u6797\u5185\u5206\u79bb\u5f0f\u96f6\u51b7\u6c34\u70ed\u6c34\uff1b\u6309 GEO \u4e94\u6b65\u6cd5\u7f16\u5236\uff0c\u62a5\u4ef7\u4f9d\u636e\u9f99\u8109 2026 V5.0 \u4ef7\u683c\u5e93\u3002\u4e24\u65b9\u6848\u5747\u542b\u8d1f\u4e00\u697c 72X1DQ1 \u72ec\u7acb\u98ce\u7ba1\u673a\uff0c\u5730\u6696\u542b\u4e8c\u6b21\u7cfb\u7edf\uff0c\u70ed\u6c34\u8fdc\u8ddd\u5206\u79bb\u4fdd\u8bc1\u5373\u5f00\u5373\u70ed\u3002<\/span><\/div>\n<\/div>\n\n<!-- ===== \u5ba2\u6237\u6210\u529f\u4e94\u6b65\u6cd5 \u00b7 \u6b65\u9aa4\u5bfc\u822a\u6761 + \u5b50\u76ee\u5f55\u5bfc\u822a\uff08\u5438\u9876\uff09 ===== -->\n<nav class=\"stepbar\" aria-label=\"\u5ba2\u6237\u6210\u529f\u4e94\u6b65\u6cd5\u5bfc\u822a\">\n  <a href=\"#s1\" data-target=\"s1\"><span class=\"n\">1<\/span><span class=\"t\">S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/span><span class=\"d\">\u7406\u89e3\u5ba2\u6237\u9700\u6c42<br>\u8bbe\u5b9a\u53ef\u9a8c\u8bc1\u627f\u8bfa<\/span><\/a>\n  <a href=\"#s2\" data-target=\"s2\"><span class=\"n\">2<\/span><span class=\"t\">S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/span><span class=\"d\">\u9700\u6c42\u2192\u75db\u70b9\u2192\u8bca\u65ad<br>\u7b2c\u4e8c\u5c42\u601d\u7ef4<\/span><\/a>\n  <a href=\"#s3\" data-target=\"s3\"><span class=\"n\">3<\/span><span class=\"t\">S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4<\/span><span class=\"d\">\u7a7a\u8c03\/\u5730\u6696\/\u70ed\u6c34<br>\u62a5\u4ef7\u4e0e 20 \u5e74\u603b\u8d26<\/span><\/a>\n  <a href=\"#s4\" data-target=\"s4\"><span class=\"n\">4<\/span><span class=\"t\">S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/span><span class=\"d\">\u7cbe\u5de5\u7cbe\u5320\u9a8c\u6536<br>\u670d\u52a1\u627f\u8bfa<\/span><\/a>\n  <a href=\"#s5\" data-target=\"s5\"><span class=\"n\">5<\/span><span class=\"t\">S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<\/span><span class=\"d\">\u6863\u6848\u4eea\u8868\u76d8<br>AI \u9a8c\u8bc1 \u00b7 \u957f\u671f<\/span><\/a>\n<\/nav>\n<div class=\"subnav-bar\">\n<div class=\"subnav\">\n  <a href=\"#s3-ac\">\u7a7a\u8c03\u53cc\u65b9\u6848<\/a>\n  <a href=\"#s3-floor\">\u5730\u6696\u4e09\u65b9\u6848<\/a>\n  <a href=\"#s3-water\">\u5206\u79bb\u5f0f\u70ed\u6c34<\/a>\n  <a href=\"#s3-prod\">\u4ea7\u54c1\u4ecb\u7ecd<\/a>\n  <a href=\"#s3\">\u62a5\u4ef7\u4e0e 20 \u5e74\u603b\u8d26<\/a>\n  <a href=\"#s4\">\u65bd\u5de5\u4ea4\u4ed8\u4fdd\u969c<\/a>\n  <a href=\"#s5\">\u6848\u4f8b\u9a8c\u8bc1<\/a>\n  <a href=\"#auth-store\">\u6388\u6743\u4e0e\u95e8\u5e97<\/a>\n  <a href=\"#faq\">\u5e38\u89c1\u95ee\u9898<\/a>\n  <a href=\"#links\">\u5ef6\u4f38\u9605\u8bfb<\/a>\n<\/div>\n<\/div>\n\n<!-- ============ S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807 ============ -->\n<section id=\"s1\">\n  <div class=\"sec-h\"><div class=\"num\">1<\/div><div><h2>S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2><div class=\"en\">Customer Success Goals \u00b7 \u8ba9\u5ba2\u6237\u786e\u8ba4\u300c\u4f60\u7406\u89e3\u5f97\u5bf9\u300d<\/div><\/div><\/div>\n  <div class=\"sec-nav\"><span class=\"sn-label\">\u672c\u8282\u5bfc\u822a<\/span><a href=\"#s1-info\">\u5ba2\u6237\u4fe1\u606f\u5361<\/a><a href=\"#s1-load\">\u51b7\u8d1f\u8377\u5206\u6790<\/a><\/div>\n\n  <div class=\"card\">\n    <h3 id=\"s1-info\">\u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n    <div class=\"kv\">\n      <b>\u5ba2\u6237<\/b><span>\u738b\u5148\u751f\u3001\u592b\u4eba\uff08\u5b50\u5973\u5916\u5730\uff0c\u5076\u5c14\u56de\u6765\uff09\uff1b\u5e38\u4f4f 2 \u4eba<\/span>\n      <b>\u623f\u5c4b<\/b><span>\u6210\u90fd\u5408\u9662\u522b\u5885\uff0c\u8d1f\u4e00\u697c \/ \u5939\u5c42\u8f66\u5e93 \/ \u4e00\u697c \/ \u4e8c\u697c \/ \u4e09\u697c\uff0c\u4e8c\u624b\u623f\u51c6\u5907\u88c5\u4fee<\/span>\n      <b>\u6838\u5fc3\u8bc9\u6c42<\/b><span>\u5168\u5c4b\u5236\u51b7\u5236\u70ed\u8212\u9002\u3001\u5730\u6696\u5168\u94fa\u3001\u70ed\u6c34\u5373\u5f00\u5373\u70ed\u3001\u521d\u6295\u4e0e\u957f\u671f\u80fd\u8017\u5e73\u8861<\/span>\n      <b>\u9009\u578b\u503e\u5411<\/b><span>\u4e2d\u592e\u7a7a\u8c03\u53cc\u7cfb\u7edf\uff08\u591a\u8054\u673a + \u8d1f\u4e00\u697c\u72ec\u7acb\u98ce\u7ba1\u673a\uff09\uff1b\u5730\u6696\u4e09\u6863\uff1b\u70ed\u6c34\u5206\u79bb\u5f0f<\/span>\n      <b>\u4fe1\u606f\u8d28\u91cf<\/b><span>\u2605\u2605\u2605\u2605\u2606 \u914d\u7f6e\u4fe1\u606f\u5b8c\u6574\uff0c\u697c\u5c42\u70ed\u8d1f\u8377\u4e0e\u8bbe\u5907\u9009\u578b\u5f85\u73b0\u573a\u52d8\u6d4b\u6700\u7ec8\u786e\u8ba4<\/span>\n    <\/div>\n  <\/div>\n\n  <div class=\"ok-line\"><b>\u5ba2\u6237\u6210\u529f\u76ee\u6807\uff1a<\/b>\u4e3a\u738b\u5148\u751f\u4ea4\u4ed8\u4e00\u5957\u300c\u591a\u5c42\u522b\u5885\u5168\u5c4b\u8212\u9002\u51b7\u6696 + \u5373\u5f00\u5373\u70ed\u70ed\u6c34\u300d\u7684\u7cfb\u7edf\u3002\u53ef\u9a8c\u8bc1\u627f\u8bfa\uff1a\u2460 7 \u7a7a\u95f4\u72ec\u7acb\u6e29\u63a7\uff1b\u2461 \u5730\u6696 182.1\u33a1 \u5168\u94fa\uff1b\u2462 \u4e8c\u4e09\u697c\u70ed\u6c34\u5373\u5f00\u5373\u70ed\uff08\u56de\u6c34\u5faa\u73af\uff09\uff1b\u2463 \u63d0\u4f9b\u53cc\u7a7a\u8c03\u65b9\u6848 + \u4e09\u5730\u6696\u65b9\u6848 + 20 \u5e74\u603b\u8d26\u5bf9\u6bd4\uff0c\u8f85\u52a9\u51b3\u7b56\u3002<\/div>\n\n  <h3 id=\"s1-load\">\u5404\u533a\u57df\u7a7a\u8c03\u51b7\u8d1f\u8377\uff08\u6309 160W\/\u33a1 \u8bbe\u8ba1\u6807\u51c6\uff09<\/h3>\n  <p class=\"lead\">\u4e0b\u8868\u4e0e\u56fe\u8868\u4f9d\u636e\u6307\u4ee4 \u00a76.6 \u7a7a\u8c03\u51b7\u8d1f\u8377\u6807\u51c6 160W\/\u33a1 \u8ba1\u7b97\uff0c\u9a8c\u8bc1\u300c\u5185\u673a\u5bb9\u91cf \u2265 \u533a\u57df\u51b7\u8d1f\u8377\u300d\u3002\u591a\u8054\u673a\u8986\u76d6\u4e00\u697c\u81f3\u4e09\u697c 7 \u4e2a\u7a7a\u95f4\uff1b\u8d1f\u4e00\u697c\u7531\u72ec\u7acb 72X1DQ1 \u98ce\u7ba1\u673a\uff087.2kW\uff0c\u4e0d\u5e26\u6cf5\uff09\u53e6\u884c\u8986\u76d6\u3002<\/p>\n  <div class=\"chart-box\" id=\"chartArea\"><\/div>\n  <p class=\"muted\">\u56fe\uff1a\u5404\u533a\u57df\u9762\u79ef\u4e0e\u51b7\u8d1f\u8377\uff08160W\/\u33a1\uff09\u5bf9\u6bd4\uff0c\u5185\u673a\u9009\u578b\u5bb9\u91cf\u5747 \u2265 \u533a\u57df\u8d1f\u8377\uff0c\u5197\u4f59\u5408\u7406\u3002<\/p>\n<\/section>\n\n<!-- ============ S2 \u9700\u6c42\u75db\u70b9\u8bca\u65ad ============ -->\n<section id=\"s2\">\n  <div class=\"sec-h\"><div class=\"num\">2<\/div><div><h2>S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/h2><div class=\"en\">Diagnosis \u00b7 \u7b2c\u4e8c\u5c42\u601d\u7ef4\u8bca\u65ad<\/div><\/div><\/div>\n  <div class=\"sec-nav\"><span class=\"sn-label\">\u672c\u8282\u5bfc\u822a<\/span><a href=\"#s2-diag\">\u75db\u70b9\u8bca\u65ad\u8868<\/a><a href=\"#s2-dim\">\u7ef4\u5ea6\u9886\u5148\u5bf9\u6bd4<\/a><\/div>\n\n  <div class=\"card\">\n    <h3 id=\"s2-diag\">\u9700\u6c42 \u2192 \u75db\u70b9 \u2192 \u8bca\u65ad \u5bf9\u9f50\u8868\uff08\u7b2c\u4e8c\u5c42\u601d\u7ef4\u8bca\u65ad\uff09<\/h3>\n    <table>\n      <thead><tr><th>\u5ba2\u6237\u8bf4\u7684<\/th><th>\u80cc\u540e\u7684\u6280\u672f\u672c\u8d28<\/th><th>\u6211\u4eec\u7684\u8bca\u65ad<\/th><th>\u8bbe\u8ba1\u56de\u5e94<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5168\u5c4b\u90fd\u8981\u51c9\u5feb\u6696\u548c<\/td><td>\u591a\u5c42\u522b\u5885\u9700\u5206\u533a\u72ec\u7acb\u63a7\u6e29<\/td><td>\u4e00\u62d6\u4e03\u591a\u8054\u673a\u8986\u76d6 1-3 \u697c\uff0c\u8d1f\u4e00\u697c\u72ec\u7acb\u98ce\u7ba1\u673a<\/td><td>\u53cc\u7cfb\u7edf\u4e92\u4e0d\u5e72\u6270\uff0c\u6309\u5c42\u4f7f\u7528<\/td><\/tr>\n        <tr><td>\u5730\u6696\u8981\u5168\u94fa\u3001\u8212\u670d<\/td><td>182\u33a1\u5927\u9762\u79ef\u9700\u4e8c\u6b21\u7cfb\u7edf\u6c34\u529b\u5e73\u8861<\/td><td>24kW \u51b7\u51dd\u7089 + \u4e8c\u6b21\u7cfb\u7edf + \u5206\u63a7<\/td><td>\u4e09\u6863\u9009\u578b\uff0c\u63a8\u8350 119 \u5206\u63a7<\/td><\/tr>\n        <tr><td>\u4e8c\u697c\u4e09\u697c\u70ed\u6c34\u8981\u5feb<\/td><td>\u8fdc\u7aef\u7ba1\u8def\u957f\uff0c\u51b7\u6c34\u6bb5\u591a<\/td><td>\u5206\u79bb\u5f0f\uff1a\u5a01\u80fd\u5e26\u4e00\u697c\u3001\u6797\u518524L\u96f6\u51b7\u6c34\u5e26\u4e8c\u4e09\u697c<\/td><td>\u56de\u6c34\u7ba1\u5faa\u73af\uff0c\u5373\u5f00\u5373\u70ed<\/td><\/tr>\n        <tr><td>\u957f\u671f\u7528\u7740\u522b\u592a\u8d35<\/td><td>\u5173\u6ce8 20 \u5e74\u603b\u8d26\u800c\u975e\u4ec5\u521d\u6295<\/td><td>\u8212\u4eab\u7ecf\u6d4e \/ \u5c0a\u777f\u6e29\u6e7f\u53cc\u63a7\u957f\u671f\u8282\u80fd<\/td><td>\u53cc\u65b9\u6848 + 20\u5e74\u603b\u8d26\u5bf9\u6bd4<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"warn-line\"><b>\u9690\u6027\u7269\u7406\u7ea6\u675f\uff08\u5f85\u73b0\u573a\u52d8\u6d4b\u786e\u8ba4\uff09\uff1a<\/b>\u2460 \u4e2d\u592e\u7a7a\u8c03 22.4kW \u5916\u673a\u5b89\u88c5\u4f4d\u9700\u79bb\u5899 \u226530cm \u901a\u98ce\u7a7a\u95f4\uff1b\u2461 \u8d1f\u4e00\u697c 72X1DQ1 \u98ce\u7ba1\u673a\u540a\u9876\u51c0\u7a7a \u2265200mm \u4e14\u9884\u7559\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u7a7a\u95f4\uff1b\u2462 \u5730\u6696\u4e8c\u6b21\u7cfb\u7edf\u9700\u8bbe\u5907\u95f4\u9884\u7559\u589e\u538b\u6cf5\u3001\u6c34\u529b\u5206\u538b\u5668\u4f4d\u7f6e\uff1b\u2463 24kW \u51b7\u51dd\u7089\u5b9e\u9645\u5e26\u8f7d\u4ee5\u73b0\u573a\u70ed\u8d1f\u8377\u590d\u6838\u4e3a\u51c6\u3002<\/div>\n\n  <h3 id=\"s2-dim\">\u65b9\u6848 A \/ B \u7ef4\u5ea6\u9886\u5148\u5bf9\u6bd4<\/h3>\n  <p class=\"lead\">\u5c06\u5ba2\u6237\u56db\u5927\u75db\u70b9\u8f6c\u8bd1\u4e3a\u53ef\u91cf\u5316\u7ef4\u5ea6\uff0c\u76f4\u89c2\u5448\u73b0\u4e24\u65b9\u6848\u5404\u81ea\u9886\u5148\u9879\uff0c\u8f85\u52a9\u51b3\u7b56\uff08\u8be6\u89c1 S3 \u516d\u7ef4\u8bc4\u5206\u8868\uff09\u3002<\/p>\n  <div class=\"chart-box\" id=\"chartDim\"><\/div>\n  <p class=\"muted\">\u56fe\uff1a\u516d\u7ef4\u5ea6\u8bc4\u5206\u5bf9\u6bd4\u2014\u2014\u65b9\u6848 A\uff08\u8212\u4eab\uff09\u5728\u521d\u6295\u8d44\u3001\u7ef4\u62a4\u8d39\u9886\u5148\uff1b\u65b9\u6848 B\uff08\u5c0a\u777f\u5168\u6548II\uff09\u5728\u8fd0\u884c\u8d39\u3001\u8212\u9002\u5ea6\u9886\u5148\uff1b\u7a33\u5b9a\u6027\u3001\u5bff\u547d\u6301\u5e73\u3002<\/p>\n<\/section>\n\n<!-- ============ S3 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4 ============ -->\n<section id=\"s3\">\n  <div class=\"sec-h\"><div class=\"num\">3<\/div><div><h2>S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4<\/h2><div class=\"en\">Options & Cost \u00b7 \u8bbe\u5907\/\u5b89\u88c5\u5206\u5217 \u00b7 \u957f\u671f\u89c6\u89d2<\/div><\/div><\/div>\n  <div class=\"sec-nav\"><span class=\"sn-label\">\u672c\u8282\u5bfc\u822a<\/span><a href=\"#s3-ac\">\u7a7a\u8c03\u53cc\u65b9\u6848<\/a><a href=\"#s3-floor\">\u5730\u6696\u4e09\u65b9\u6848<\/a><a href=\"#s3-water\">\u5206\u79bb\u5f0f\u70ed\u6c34<\/a><a href=\"#s3-prod\">\u4ea7\u54c1\u7b80\u4ecb<\/a><a href=\"#s3-six\">\u516d\u7ef4\u5bf9\u6bd4<\/a><a href=\"#s3-quote\">\u62a5\u4ef7\u660e\u7ec6<\/a><a href=\"#s3-20y\">20\u5e74\u603b\u8d26<\/a><\/div>\n\n  <div class=\"card note\">\n    <p><b>\u26a0\ufe0f \u62a5\u4ef7\u4f9d\u636e\u4e0e\u8bf4\u660e\uff1a<\/b>\u4ee5\u4e0b\u62a5\u4ef7\u4ee5 <b>\u9f99\u8109\u6696\u901a 2026 \u5e74 V5.0 \u4ef7\u683c\u6307\u4ee4\u5e93<\/b>\uff08page_id=662\uff09\u4e3a\u552f\u4e00\u771f\u503c\u6e90\u3002\u7a7a\u8c03\u8bbe\u5907\u4ef7\u6309\u9762\u4ef7\u6298\u6263\u6838\u7b97\uff08\u8212\u4eab <b>8 \u6298<\/b> \/ \u5c0a\u777f\u5168\u6548II <b>8.5 \u6298<\/b>\uff09\uff0c<b>\u8d1f\u4e00\u697c 72X1DQ1 \u98ce\u7ba1\u673a\uff08\u4e0d\u5e26\u6cf5\uff09\u8bbe\u5907\u4ef7\u4e0d\u6253\u6298\uff08\u9762\u4ef7 5500 \u5143\uff09<\/b>\uff1b\u5b89\u88c5\u8d39\uff082 \u7ba1\u5185\u673a 1700 \u5143\/\u53f0\u30013 \u7ba1\u5185\u673a 1900 \u5143\/\u53f0\u3001\u98ce\u7ba1\u673a 1800 \u5143\/\u5957\u3001\u5916\u673a 600 \u5143\/\u53f0\uff09\u53ca WiFi \u7ebf\u63a7\u5668<b>\u5747\u4e0d\u6253\u6298<\/b>\uff1b\u5a01\u80fd\u51b7\u51dd\u7089\u3001\u6797\u5185\u70ed\u6c34\u5668\u6309<b>\u4f18\u60e0\u4ef7<\/b>\u6838\u7b97\uff1b\u5730\u6696\u6309\u9762\u79ef\u5957\u9910\uff08\u5143\/\u33a1\uff09\u3002\u51b7\u51dd\u7089\u3001\u7a7a\u8c03\u5916\u673a\u7b26\u5408\u56fd\u8865\u6761\u4ef6\uff0815% \u5c01\u9876 1500 \u5143\uff09\uff0c\u53ef\u989d\u5916\u62b5\u6263\u3002\u5730\u6696\u6863\u4f4d\uff1a\u6807\u51c6\u5e93\u4e3a 99\/119\/155\/179 \u5143\/\u33a1\uff0c\u672c\u6848\u6309\u5ba2\u6237\u9700\u6c42\u91c7\u7528\u516c\u53f8\u8282\u80fd\u8bbe\u8ba1\u5b9a\u5236\u6863 <b>169 \u5143\/\u33a1<\/b>\u3002<\/p>\n  <\/div>\n\n  <!-- \u7a7a\u8c03 -->\n  <h3 id=\"s3-ac\">3.1 \u7a7a\u8c03\u7cfb\u7edf \u00b7 \u53cc\u65b9\u6848\u5bf9\u6bd4\uff08\u591a\u8054\u673a\u4e00\u62d6\u4e03 + \u8d1f\u4e00\u697c\u72ec\u7acb\u98ce\u7ba1\u673a\uff09<\/h3>\n  <p class=\"lead\">\u4e24\u65b9\u6848\u5171\u7528\uff1a<b>22.4kW \u5916\u673a\uff08\u4e00\u62d6\u4e03\uff09<\/b>\u8986\u76d6\u4e00\u697c\u81f3\u4e09\u697c 7 \u4e2a\u7a7a\u95f4\uff0c<b>\u8d1f\u4e00\u697c\u7edf\u4e00\u914d\u7f6e\u65e5\u7acb 72X1DQ1 \u98ce\u7ba1\u673a\uff087.2kW\uff0c\u4e0d\u5e26\u6cf5\uff09<\/b>\u72ec\u7acb\u7cfb\u7edf\u3002\u5dee\u5f02\u5728\u4e3b\u673a\u7cfb\u5217\u4e0e\u5185\u673a\u914d\u7f6e\u903b\u8f91\u3002<\/p>\n  <div class=\"two-col\">\n    <div class=\"card\">\n      <span class=\"scheme-tag tag-a\">\u65b9\u6848 A \u00b7 \u65e5\u7acb\u8212\u4eab EX\u8212\u4eab<\/span>\n      <h4>\u5b9a\u4f4d\uff1a\u7ecf\u6d4e\u5b9e\u7528\u578b<\/h4>\n      <p class=\"muted\">\u591a\u8054\u673a RAS-224HRNBQ\uff0822.4kW\uff09+ 7 \u53f0 EX\u8212\u4eab DC \u6807\u51c6\u5185\u673a\u3002\u8bbe\u5907\u4ef7\u6309\u9762\u4ef7 <b>8 \u6298<\/b>\u3002\u8d1f\u4e00\u697c <b>72X1DQ1 \u98ce\u7ba1\u673a\uff08\u4e0d\u5e26\u6cf5\uff0c\u9762\u4ef7 5500 \u5143\uff0c\u4e0d\u6253\u6298\uff09<\/b>\u72ec\u7acb\u8fd0\u884c\u3002<\/p>\n      <p><b>\u89e3\u51b3\u60a8\u7684\u62c5\u5fc3\uff1a<\/b>\u521d\u6295\u8d44\u53ef\u63a7\uff0c\u7cfb\u7edf\u7b80\u6d01\u7a33\u5b9a\uff0c\u6ee1\u8db3\u5168\u5c4b\u57fa\u7840\u5236\u51b7\u5236\u70ed\u3002<\/p>\n    <\/div>\n    <div class=\"card\">\n      <span class=\"scheme-tag tag-b\">\u65b9\u6848 B \u00b7 \u5c0a\u777f\u5168\u6548II<\/span>\n      <h4>\u5b9a\u4f4d\uff1a\u6e29\u6e7f\u53cc\u63a7\u8212\u9002\u578b<\/h4>\n      <p class=\"muted\">\u591a\u8054\u673a RAS-224FSXPN5Q\uff0822.4kW\uff09\u3002<b>\u5ba2\u5385\u4e0e\u4e3b\u5367+\u8863\u5e3d\u95f4\u7528\u4e09\u7ba1\u5236\u5185\u673a<\/b>\uff08\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u3001\u5168\u5e74\u9664\u6e7f\u4e0d\u964d\u6e29\uff09\uff0c<b>\u5176\u4f59\u7a7a\u95f4\u7528\u4e24\u7ba1\u51c0\u5316\u578b\u5185\u673a<\/b>\uff08DC \u5168\u98ce\u8def\u51c0\u5316\uff09\u3002\u8bbe\u5907\u4ef7\u6309\u9762\u4ef7 <b>8.5 \u6298<\/b>\uff0c\u8d1f\u4e00\u697c 72X1DQ1 \u98ce\u7ba1\u673a\uff08\u4e0d\u5e26\u6cf5\uff0c\u9762\u4ef7 5500 \u5143\uff09\u4e0d\u6253\u6298\u3002<\/p>\n      <p><b>\u89e3\u51b3\u60a8\u7684\u62c5\u5fc3\uff1a<\/b>\u6210\u90fd\u9ad8\u6e7f\u73af\u5883\u4e0b\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\uff0c\u8212\u9002\u5ea6\u9ad8\u3001\u957f\u671f\u9664\u6e7f\u80fd\u8017\u66f4\u4f18\u3002<\/p>\n    <\/div>\n  <\/div>\n  <h4>\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u660e\u7ec6\u8868\uff08\u591a\u8054\u673a\u4e00\u62d6\u4e03 \u00b7 \u4e24\u65b9\u6848\u540c\u5bb9\u91cf\uff09<\/h4>\n  <table>\n    <thead><tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u51b7\u8d1f\u8377<br>(160W\/\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7\uff08\u65b9\u6848A \/ \u65b9\u6848B\uff09<\/th><th>\u5bb9\u91cf<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e00\u697c<\/td><td>\u5ba2\u5385<\/td><td>35.7\u33a1<\/td><td>5.7kW<\/td><td>RPIZ-63FSNAQD\/P&nbsp;\/&nbsp;RPIZ-71FSVN2QB\/PC\uff08\u4e09\u7ba1\uff09<\/td><td>7.1kW<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e00\u697c<\/td><td>\u9910\u5385+\u53a8\u623f<\/td><td>17.0\u33a1<\/td><td>2.7kW<\/td><td>RPIZ-40FSNAQD\/P&nbsp;\/&nbsp;RPIZ-40FSVNZ1QD\/PC\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>4.0kW<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u53671<\/td><td>15.0\u33a1<\/td><td>2.4kW<\/td><td>RPIZ-28FSNAQD\/P&nbsp;\/&nbsp;RPIZ-28FSVNZ1QD\/PC\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>2.8kW<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u53672<\/td><td>9.6\u33a1<\/td><td>1.5kW<\/td><td>RPIZ-18FSNAQD\/P&nbsp;\/&nbsp;RPIZ-18FSVNZ1QD\/PC\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>1.8kW<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u53673<\/td><td>17.0\u33a1<\/td><td>2.7kW<\/td><td>RPIZ-32FSNAQD\/P&nbsp;\/&nbsp;RPIZ-36FSVNZ1QD\/PC\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>3.6kW<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e09\u697c<\/td><td>\u4e3b\u5367+\u8863\u5e3d\u95f4<\/td><td>22.0\u33a1<\/td><td>3.5kW<\/td><td>RPIZ-45FSNAQD\/P&nbsp;\/&nbsp;RPIZ-45FSVN2QB\/PC\uff08\u4e09\u7ba1\uff09<\/td><td>4.5kW<\/td><td>1<\/td><\/tr>\n      <tr><td>\u4e09\u697c<\/td><td>\u4e66\u623f<\/td><td>10.0\u33a1<\/td><td>1.6kW<\/td><td>RPIZ-18FSNAQD\/P&nbsp;\/&nbsp;RPIZ-18FSVNZ1QD\/PC\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>1.8kW<\/td><td>1<\/td><\/tr>\n      <tr class=\"total-row\"><td colspan=\"2\">\u5408\u8ba1<\/td><td>\u2014<\/td><td>20.2kW<\/td><td>7 \u53f0\u5185\u673a<\/td><td>25.6kW<\/td><td>7<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"pill\">\n    <div class=\"p\">\u5916\u673a\u529f\u7387 <b>22.4 kW<\/b><\/div>\n    <div class=\"p\">\u5185\u673a\u603b\u529f\u7387 <b>25.6 kW<\/b><\/div>\n    <div class=\"p\">\u8d85\u914d\u7387 <b>114%<\/b> <span class=\"badge\">\u65e5\u7acb\u5141\u8bb8\u4e0a\u9650130%<\/span><\/div>\n    <div class=\"p\">\u8d1f\u4e00\u697c <b>72X1DQ1 \u98ce\u7ba1\u673a 7.2kW\uff08\u4e0d\u5e26\u6cf5\uff09<\/b>\uff08\u4e24\u65b9\u6848\u5171\u7528\uff09<\/div>\n  <\/div>\n  <div class=\"ok-line\">\u9009\u578b\u903b\u8f91\uff1a22.4kW \u5916\u673a\u914d 25.6kW \u5185\u673a\uff0c\u8d85\u914d\u7387 114% \u5904\u4e8e\u5b89\u5168\u5408\u7406\u533a\u95f4\uff08\u65e5\u7acb\u5141\u8bb8\u4e0a\u9650 130%\uff09\u3002\u7ed3\u5408\u5e38\u4f4f 2 \u4eba\u7684\u4f7f\u7528\u4e60\u60ef\uff0c\u7cfb\u7edf\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u9ad8\u6548\u8fd0\u884c\uff0c\u521d\u6295\u8d44\u4e0e\u957f\u671f\u80fd\u8017\u5747\u4f18\u4e8e\u76f2\u76ee\u653e\u5927\u5916\u673a\u3002<\/div>\n  <div class=\"chart-box\" id=\"chartAC\"><\/div>\n  <p class=\"muted\">\u56fe\uff1a\u65b9\u6848 A\uff08\u8212\u4eab 8 \u6298\uff09\u4e0e\u65b9\u6848 B\uff08\u5c0a\u777f\u5168\u6548II 8.5 \u6298\uff09\u7a7a\u8c03\u7cfb\u7edf\u62a5\u4ef7\u6784\u6210\u5bf9\u6bd4\uff08\u8bbe\u5907\u6298\u540e \/ \u5b89\u88c5\u8d39\uff09\u3002\u8d1f\u4e00\u697c 72X1DQ1 \u98ce\u7ba1\u673a\u4e24\u65b9\u6848\u76f8\u540c\uff0c\u5df2\u8ba1\u5165\u3002<\/p>\n\n  <!-- \u5730\u6696 -->\n  <h3 id=\"s3-floor\">3.2 \u5730\u6696\u7cfb\u7edf \u00b7 \u4e09\u65b9\u6848\u5bf9\u6bd4\uff08\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl + \u4e8c\u6b21\u7cfb\u7edf\uff09<\/h3>\n  <p class=\"lead\">\u70ed\u6e90\u7edf\u4e00\u4e3a <b>\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl 24kW<\/b>\uff08\u8d1f\u8d23\u5168\u5c4b\u5730\u6696 + \u4e00\u697c\u751f\u6d3b\u70ed\u6c34\uff09\uff1b\u5168\u5c4b\u5730\u6696\u94fa\u8bbe\u9762\u79ef <b>182.1\u33a1<\/b>\uff1b\u7edf\u4e00\u589e\u52a0 <b>\u4e8c\u6b21\u7cfb\u7edf<\/b>\uff08\u589e\u538b\u6cf5 + \u6c34\u529b\u5206\u538b\u5668\uff0c\u5e94\u5bf9\u5927\u6d41\u91cf\u957f\u7ba1\u8def\uff09\uff1b\u4e3b\u7ba1 De32 \u8d77\u6b65\u3002\u4e09\u65b9\u6848\u5dee\u5f02\u4ec5\u5728\u76d8\u7ba1\/\u63a7\u5236\u6863\u4f4d\u3002<\/p>\n  <table>\n    <thead><tr><th>\u65b9\u6848<\/th><th>\u6863\u4f4d<\/th><th>\u914d\u7f6e\u8981\u70b9<\/th><th>\u5355\u4ef7<\/th><th>\u9762\u79ef<\/th><th>\u9762\u79ef\u8d39\u7528<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td><b>\u5730\u6696\u2460<\/b><\/td><td>\u5e02\u573a\u901a\u914d\u603b\u63a7<\/td><td>\u4f1f\u661f\u603b\u63a7 \u00b7 \u7ba125-16 \u00b7 \u8bfa\u5c14\u677f \u00b7 15\u33a1\/\u56de\u8def \u00b7 150\u95f4\u8ddd<\/td><td>99 \u5143\/\u33a1<\/td><td>182.1\u33a1<\/td><td>\u00a518028<\/td><\/tr>\n      <tr><td><b>\u5730\u6696\u2461<\/b><\/td><td>\u5e02\u573a\u901a\u914d\u5206\u63a7<\/td><td>\u66fc\u745e\u5fb7\u5206\u63a7 \u00b7 \u53ef\u5206\u5c42\u72ec\u7acb\u63a7\u6e29 \u00b7 \u540c\u4e0a\u76d8\u7ba1<\/td><td>119 \u5143\/\u33a1<\/td><td>182.1\u33a1<\/td><td>\u00a521670<\/td><\/tr>\n      <tr><td><b>\u5730\u6696\u2462<\/b><\/td><td>\u516c\u53f8\u8282\u80fd\u8bbe\u8ba1<\/td><td>32-20 \u7ba1 \u00b7 \u6d41\u91cf+100% \u00b7 \u8282\u80fd50% \u00b7 WiFi \u00b7 \u4e09\u65b9\u8054\u4fdd<\/td><td>169 \u5143\/\u33a1<\/td><td>182.1\u33a1<\/td><td>\u00a530775<\/td><\/tr>\n      <tr class=\"total-row\"><td colspan=\"4\">\u4e09\u65b9\u6848\u5747\u542b\uff1a\u4e8c\u6b21\u7cfb\u7edf \u00a53000 + \u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl 24kW \u00a511715 + \u5b89\u88c5 \u00a5600<\/td><td>\u5408\u8ba1<\/td><td>\u89c1\u62a5\u4ef7\u7ae0<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"chart-box\" id=\"chartFloor\"><\/div>\n  <p class=\"muted\">\u56fe\uff1a\u4e09\u5730\u6696\u65b9\u6848\u62a5\u4ef7\u6784\u6210\u5bf9\u6bd4\uff08\u9762\u79ef\u5957\u9910 \/ \u4e8c\u6b21\u7cfb\u7edf \/ \u51b7\u51dd\u7089\u542b\u5b89\u88c5\uff09\u3002\u4e09\u65b9\u6848\u70ed\u6e90\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u5b8c\u5168\u4e00\u81f4\uff0c\u5dee\u5f02\u5728\u76d8\u7ba1\u63a7\u5236\u6863\u4f4d\u3002<\/p>\n  <div class=\"card tip\">\n    <h4>\u5730\u6696\u9009\u578b\u5efa\u8bae<\/h4>\n    <p>182\u33a1 \u522b\u5885\uff0c<b>\u63a8\u8350\u5730\u6696\u2461\uff08119 \u5206\u63a7\uff09\u8d77\u6b65<\/b>\uff1a\u66fc\u745e\u5fb7\u5206\u63a7\u53ef\u6309\u697c\u5c42\/\u623f\u95f4\u72ec\u7acb\u542f\u505c\uff0c\u914d\u5408\u4e8c\u6b21\u7cfb\u7edf\u6c34\u529b\u5e73\u8861\uff0c\u65e2\u8282\u80fd\u53c8\u907f\u514d\u300c\u5f00\u4e00\u5c4b\u6696\u5168\u5c4b\u300d\u7684\u6d6a\u8d39\u3002\u9884\u7b97\u5145\u88d5\u9009\u5730\u6696\u2462\uff08169 \u8282\u80fd\u8bbe\u8ba1\uff0c\u6d41\u91cf\u63d0\u5347+WiFi \u8054\u52a8\uff0c\u957f\u671f\u8282\u80fd\u7ea6 50%\uff09\u3002\u5730\u6696\u2460\uff0899 \u603b\u63a7\uff09\u9002\u5408\u4f5c\u4e3a\u57fa\u7840\u6863\u5bf9\u6bd4\u3002<\/p>\n  <\/div>\n\n  <!-- \u70ed\u6c34 -->\n  <h3 id=\"s3-water\">3.3 \u70ed\u6c34\u7cfb\u7edf \u00b7 \u5206\u79bb\u5f0f\u8bbe\u8ba1<\/h3>\n  <div class=\"two-col\">\n    <div class=\"card\">\n      <span class=\"scheme-tag tag-f\">\u70ed\u6e90\u4e00 \u00b7 \u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl 24kW<\/span>\n      <p>\u4f4d\u4e8e\u4e00\u697c\uff0c\u8d1f\u8d23 <b>\u5168\u5c4b\u5730\u6696 + \u4e00\u697c\u536b\u751f\u95f4\u53ca\u6d17\u624b\u53f0\u70ed\u6c34<\/b>\u3002\u51b7\u51dd\u7089\u9ad8\u6548\u4f9b\u70ed\uff0c\u4e00\u7089\u4e24\u7528\u3002<\/p>\n      <p class=\"muted\">\u8bbe\u5907 \u00a511715\uff08\u9762\u4ef7 \u00a516735\uff0c\u4f18\u60e0\u4ef7\uff09+ \u5b89\u88c5 \u00a5600 = \u00a512315<\/p>\n    <\/div>\n    <div class=\"card\">\n      <span class=\"scheme-tag tag-f\">\u70ed\u6e90\u4e8c \u00b7 \u6797\u5185 24L \u96f6\u51b7\u6c34<\/span>\n      <p>\u4f4d\u4e8e\u4e00\u697c\u53a8\u623f\u9644\u8fd1\uff0c\u8d1f\u8d23 <b>\u4e8c\u697c + \u4e09\u697c\u6240\u6709\u536b\u751f\u95f4\u53ca\u6d17\u624b\u53f0\u70ed\u6c34<\/b>\u3002\u505a\u5927\u5faa\u73af\u56de\u6c34\u7ba1\uff0c\u8fdc\u7aef\u5373\u5f00\u5373\u70ed\u3002<\/p>\n      <p class=\"muted\">RUS-R24E51G-CB \u00a56499\uff08\u9762\u4ef7 \u00a58599\uff0c\u4f18\u60e0\u4ef7\uff09+ \u5b89\u88c5\u8f85\u6750 \u00a5300 = \u00a56799<\/p>\n    <\/div>\n  <\/div>\n  <div class=\"ok-line\">\u8bbe\u8ba1\u8981\u70b9\uff1a\u91c7\u6696\u7089\u4e0e\u70ed\u6c34\u5668\u5206\u79bb\uff0c\u4e92\u4e0d\u5e72\u6270\uff1b\u4e8c\u697c\u4e09\u697c\u5355\u72ec\u96f6\u51b7\u6c34\u5faa\u73af\uff0c\u907f\u514d\u957f\u7ba1\u8def\u51b7\u6c34\u6bb5\uff1b\u9700\u505a\u70ed\u6c34\u5faa\u73af\u56de\u6c34\u7ba1\uff0c\u786e\u4fdd\u5404\u697c\u5c42\u70ed\u6c34\u7ba1\u5747\u8bbe\u56de\u6c34\u3002<\/div>\n\n  <!-- \u4ea7\u54c1\u7b80\u4ecb -->\n  <h3 id=\"s3-prod\">3.4 \u6838\u5fc3\u4ea7\u54c1\u7b80\u4ecb \u00b7 \u65b9\u6848\u6d89\u53ca\u4e3b\u8981\u8bbe\u5907\u4e00\u89c8<\/h3>\n  <p class=\"lead\">\u4ee5\u4e0b\u4e3a\u672c\u65b9\u6848\u6d89\u53ca\u7684\u4e94\u5927\u6838\u5fc3\u4ea7\u54c1\uff0c\u70b9\u51fb\u4ea7\u54c1\u540d\u79f0\u53ef\u67e5\u770b\u9f99\u8109\u6696\u901a\u5b98\u7f51\u5b8c\u6574\u8be6\u60c5\u9875\u3002<\/p>\n\n  <div class=\"pcard\">\n    <img decoding=\"async\" class=\"pimg\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg\" alt=\"\u65e5\u7acb\u8212\u4eabEX\u8212\u4eab\u5916\u673a\" loading=\"lazy\">\n    <div class=\"pbody\">\n      <span class=\"ptag\">\u65b9\u6848 A \u00b7 \u65e5\u7acb EX-\u8212\u4eab<\/span>\n      <h4>RAS-224HRNBQ \u53cc\u98ce\u6247\u5916\u673a\uff0822.4kW\uff09<\/h4>\n      <p>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u5916\u673a\uff0cAPF 5.4\uff0c\u5168\u76f4\u6d41\u53d8\u9891\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c45\u2103\u9ad8\u6e29\u5236\u51b7\u4e0d\u6253\u6298\u3002\u6807\u914d\u53cd\u8f6c\u9664\u5c18\u6280\u672f\u3001\u516d\u8109\u6ce2\u7535\u78c1\u52a0\u70ed\u3002\u6700\u5927\u914d\u7ba1120m\uff0c\u652f\u6301\u4e00\u62d6\u5341\u3002192mm\u8d85\u8584\u5185\u673a\u6700\u4f4e\u4ec517dB\u3002\u9002\u7528160~185\u33a1\u4e2d\u5927\u6237\u578b\/\u522b\u5885\u3002<br><b>\u672c\u65b9\u6848\u5b9a\u4f4d\uff1a<\/b>\u7ecf\u6d4e\u5b9e\u7528\uff0c8\u6298\u540e\u6027\u4ef7\u6bd4\u7a81\u51fa\u3002<\/p>\n      <div class=\"plink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\ud83d\udcd6 \u67e5\u770b\u5b8c\u6574\u4ea7\u54c1\u624b\u518c \u2192<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=2782\" target=\"_blank\">\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u7cfb\u5217\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"pcard\">\n    <img decoding=\"async\" class=\"pimg\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" alt=\"\u65e5\u7acb\u5c0a\u777f\u5168\u6548II\" loading=\"lazy\">\n    <div class=\"pbody\">\n      <span class=\"ptag\">\u65b9\u6848 B \u00b7 \u65e5\u7acb\u5c0a\u777f\u5168\u6548II<\/span>\n      <h4>RAS-224FSXPN5Q \u53cc\u98ce\u6247\u5916\u673a\uff0822.4kW\uff09<\/h4>\n      <p>\u65e5\u7acb\u5c0a\u777f\u5168\u6548II\u65d7\u8230\u7cfb\u5217\uff0c\u884c\u4e1a\u9996\u6b3e\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u591a\u8054\u673a\uff0cAPF 5.4\u3002\u53cc\u8f6c\u5b50\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a\uff0c-25\u2103\u4f4e\u6e29\u5f3a\u5236\u70ed\uff0c60\u2103\u9ad8\u6e29\u5236\u51b7\u4e0d\u505c\u673a\u3002\u5185\u673a\u6807\u914d\u5168\u98ce\u8def\u51c0\u5316\u8231\uff08\u516d\u91cd\u51c0\u5316\uff1a\u6da1\u8f6e\u6291\u83cc\u2192\u8717\u58f3\u6291\u83cc\u2192\u63a5\u6c34\u76d8\u6291\u83cc\u2192\u7fc5\u7247\u81ea\u6e05\u6d01\u219260\u2103\u9ad8\u6e29\u9664\u83cc\u2192PE+\u51c0\u5316\u6a21\u5757\uff09\uff0cPM2.5\u53bb\u9664\u7387\u226599%\u3002<br><b>\u672c\u65b9\u6848\u5b9a\u4f4d\uff1a<\/b>\u6e29\u6e7f\u53cc\u63a7\u8212\u9002\u578b\uff0c\u5ba2\u5385\u4e0e\u4e3b\u5367+\u8863\u5e3d\u95f4\u914d\u4e09\u7ba1\u5236\u5185\u673a\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u5176\u4f59\u7a7a\u95f4\u914d\u4e24\u7ba1\u51c0\u5316\u578b\u5185\u673a\u3002<\/p>\n      <div class=\"plink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\ud83d\udcd6 \u67e5\u770b\u5b8c\u6574\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=1171\" target=\"_blank\">\u5c0a\u777f\u5168\u6548II\u65b9\u6848\u62a5\u544a \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"pcard\">\n    <img decoding=\"async\" class=\"pimg\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-03.jpeg\" alt=\"\u65e5\u7acb\u98ce\u7ba1\u673aUX Pro\" loading=\"lazy\">\n    <div class=\"pbody\">\n      <span class=\"ptag\">\u4e24\u65b9\u6848\u5171\u7528 \u00b7 \u8d1f\u4e00\u697c\u72ec\u7acb\u7cfb\u7edf<\/span>\n      <h4>\u65e5\u7acb 72X1DQ1 \u98ce\u7ba1\u673a\uff087.2kW\uff0c\u4e0d\u5e26\u6cf5\uff09<\/h4>\n      <p>\u65e5\u7acbUX\u7cfb\u5217\u98ce\u7ba1\u673a\uff0c192mm\u8d85\u8584\u673a\u8eab\uff0c\u9690\u85cf\u5f0f\u5b89\u88c5\u4e0d\u5360\u5730\u9762\u30027.2kW\u51b7\u91cf\u8986\u76d6\u8d1f\u4e00\u697c\uff08\u7ea645\u33a1\uff09\u3002\u8d85\u4e00\u7ea7\u80fd\u6548\uff08APF 3.67\uff09\uff0c\u6700\u4f4e21dB\u9759\u97f3\u3002\u6807\u914d\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01+60\u2103\u9ad8\u6e29\u9664\u83cc\u3002<br>\u8d1f\u4e00\u697c\u4e3a\u975e\u957f\u671f\u5c45\u4f4f\u7a7a\u95f4\uff0c\u914d\u7f6e\u72ec\u7acb\u98ce\u7ba1\u673a\u7075\u6d3b\u6309\u9700\u4f7f\u7528\uff0c\u4e0d\u5360\u591a\u8054\u673a\u5bb9\u91cf\u3002<\/p>\n      <div class=\"plink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=4326\" target=\"_blank\">\ud83d\udcd6 \u67e5\u770bUX Pro\u98ce\u7ba1\u673a\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"pcard\">\n    <img decoding=\"async\" class=\"pimg\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-wn-lngl-intro24-01.jpg\" alt=\"\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl\" loading=\"lazy\">\n    <div class=\"pbody\">\n      <span class=\"ptag\">\u5730\u6696\u70ed\u6e90 \u00b7 \u4e00\u697c\u70ed\u6c34<\/span>\n      <h4>\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089 ecoTEC intro 24kW<\/h4>\n      <p>\u5a01\u80fd\uff08Vaillant\uff09\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\uff0c\u56fd\u4ea7\u51b7\u51dd\u7089\u4e3b\u529b\u578b\u53f7\u3002\u5168\u9884\u6df7\u51b7\u51dd\u71c3\u70e7\u6280\u672f\uff0c30%\u90e8\u5206\u8d1f\u8377\u6548\u7387106%\uff08\u4e00\u7ea7\u80fd\u6548\uff09\uff0cNOx\u6392\u653e5\u7ea7\u73af\u4fdd\u6807\u51c6\u3002\u4f9b\u6c3435-45\u2103\u914d\u5408\u5730\u6696\u7cfb\u7edf\u51b7\u51dd\u6548\u7387\u6700\u4f73\u3002<br>\u672c\u65b9\u6848\u5b9a\u4f4d\uff1a\u8d1f\u8d23\u5168\u5c4b182\u33a1\u5730\u6696 + \u4e00\u697c\u751f\u6d3b\u70ed\u6c34\uff0c\u4e00\u7089\u4e24\u7528\uff0c\u9ad8\u6548\u8282\u80fd\u3002\u914d\u5408\u4e8c\u6b21\u7cfb\u7edf\u5e94\u5bf9\u522b\u5885\u5927\u6d41\u91cf\u957f\u7ba1\u8def\u3002<\/p>\n      <div class=\"plink\">\uff08\u9f99\u8109\u6696\u901a\u5b98\u7f51\u5a01\u80fd\u4ea7\u54c1\u9875\u66f4\u65b0\u4e2d\uff0c\u8be6\u8be2\u95e8\u5e97\uff09<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"pcard\">\n    <img decoding=\"async\" class=\"pimg\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-ln-rs-r24-01.jpg\" alt=\"\u6797\u518524L\u96f6\u51b7\u6c34\u71c3\u6c14\u70ed\u6c34\u5668\" loading=\"lazy\">\n    <div class=\"pbody\">\n      <span class=\"ptag\">\u4e8c\u4e09\u697c\u70ed\u6c34\u70ed\u6e90<\/span>\n      <h4>\u6797\u5185 24L \u96f6\u51b7\u6c34 RUS-R24E51G-CB<\/h4>\n      <p>\u6797\u5185\uff08Rinnai\uff09\u767e\u5e74\u65e5\u672c\u54c1\u724c\uff081920\u5e74\u521b\u7acb\uff09\uff0c\u71c3\u6c14\u70ed\u6c34\u884c\u4e1a\u6807\u6746\u300224L\u5927\u5bb9\u91cf\u96f6\u51b7\u6c34\u578b\uff0c\u5185\u7f6e\u5faa\u73af\u6c34\u6cf5+\u56de\u6c34\u7ba1\u8bbe\u8ba1\uff0c\u5b9e\u73b0\u4e8c\u697c\u4e09\u697c\u5373\u5f00\u5373\u70ed\u3002\u82af\u63a7\u6c34\u4f3a\u670d \u00b11\u2103\u6052\u6e29\u7cbe\u63a7\uff0c\u56db\u6bb5\u6bd4\u4f8b\u71c3\u70e7\uff08\u6700\u5c0f3.5kW\uff09\uff0c\u590f\u5929\u4e0d\u70eb\u51ac\u5929\u591f\u70ed\u3002140m\u8d85\u957f\u5faa\u73af\u7ba1\u8def\u8986\u76d6\u522b\u5885\u5168\u5c42\u3002<\/p>\n      <div class=\"plink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=2489\" target=\"_blank\">\ud83d\udcd6 \u67e5\u770b\u6797\u5185\u5168\u7cfb\u4ea7\u54c1 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u516d\u7ef4 -->\n  <h3 id=\"s3-six\">3.5 \u7a7a\u8c03\u53cc\u65b9\u6848 \u00b7 \u516d\u7ef4\u5ea6\u5bf9\u6bd4\uff08\u987a\u5e8f\u56fa\u5b9a\uff09<\/h3>\n  <table>\n    <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u65b9\u6848 A \u8212\u4eab\uff088\u6298\uff09<\/th><th>\u65b9\u6848 B \u5c0a\u777f\u5168\u6548II\uff088.5\u6298\uff09<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u521d\u6295\u8d44<\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td><td><span class=\"stars\">\u2605\u2605\u2605<\/span><\/td><td>A \u4f4e\u7ea6 \u00a520117<\/td><\/tr>\n      <tr><td>\u8fd0\u884c\u8d39<\/td><td><span class=\"stars\">\u2605\u2605\u2605<\/span><\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605<\/span><\/td><td>B \u6e29\u6e7f\u53cc\u63a7\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u957f\u671f\u66f4\u7701<\/td><\/tr>\n      <tr><td>\u8212\u9002\u5ea6<\/td><td><span class=\"stars\">\u2605\u2605\u2605<\/span><\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td><td>B \u4e09\u7ba1\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236 + \u51c0\u5316<\/td><\/tr>\n      <tr><td>\u7a33\u5b9a\u6027<\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605<\/span><\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605<\/span><\/td><td>\u540c\u54c1\u724c\u65e5\u7acb\uff0c\u5747\u53ef\u9760<\/td><\/tr>\n      <tr><td>\u7ef4\u62a4\u8d39<\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605<\/span><\/td><td><span class=\"stars\">\u2605\u2605\u2605<\/span><\/td><td>B \u51c0\u5316\/\u4e09\u7ba1\u6a21\u5757\u7ef4\u62a4\u7565\u9ad8<\/td><\/tr>\n      <tr><td>\u5bff\u547d<\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605<\/span><\/td><td><span class=\"stars\">\u2605\u2605\u2605\u2605<\/span><\/td><td>\u5747\u7ea6 15 \u5e74<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <!-- \u62a5\u4ef7\u660e\u7ec6 -->\n  <h3 id=\"s3-quote\">3.6 \u62a5\u4ef7\u660e\u7ec6\uff08\u8bbe\u5907 \/ \u5b89\u88c5\u5206\u5217\uff09<\/h3>\n  <h4>\u65b9\u6848 A \u00b7 \u65e5\u7acb\u8212\u4eab\uff088\u6298\uff09\u2014 \u603b\u8ba1 \u00a558200<\/h4>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u540e\u8bbe\u5907<\/th><th>\u5b89\u88c5\u8d39<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u591a\u8054\u673a\u5916\u673a<\/td><td>RAS-224HRNBQ\uff0822.4kW\uff09<\/td><td>1<\/td><td>24275<\/td><td>19420<\/td><td>600<\/td><\/tr>\n      <tr><td>\u5185\u673a 63\u578b<\/td><td>RPIZ-63FSNAQD\/P<\/td><td>1<\/td><td>3463<\/td><td>2770<\/td><td>1700<\/td><\/tr>\n      <tr><td>\u5185\u673a 40\u578b<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>1<\/td><td>3163<\/td><td>2530<\/td><td>1700<\/td><\/tr>\n      <tr><td>\u5185\u673a 28\u578b<\/td><td>RPIZ-28FSNAQD\/P<\/td><td>1<\/td><td>3075<\/td><td>2460<\/td><td>1700<\/td><\/tr>\n      <tr><td>\u5185\u673a 18\u578b<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>2<\/td><td>5676<\/td><td>4540<\/td><td>3400<\/td><\/tr>\n      <tr><td>\u5185\u673a 32\u578b<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1<\/td><td>3100<\/td><td>2480<\/td><td>1700<\/td><\/tr>\n      <tr><td>\u5185\u673a 45\u578b<\/td><td>RPIZ-45FSNAQD\/P<\/td><td>1<\/td><td>3250<\/td><td>2600<\/td><td>1700<\/td><\/tr>\n      <tr><td>\u8d1f\u4e00\u697c\u98ce\u7ba1\u673a<\/td><td>\u65e5\u7acb 72X1DQ1\uff087.2kW \u4e0d\u5e26\u6cf5\uff09<\/td><td>1<\/td><td>5500<\/td><td>5500<\/td><td>1800<\/td><\/tr>\n      <tr><td>WiFi \u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>8<\/td><td>1600<\/td><td>1600<\/td><td>\u2014<\/td><\/tr>\n      <tr class=\"total-row\"><td colspan=\"3\">\u8bbe\u5907\u6298\u540e\u5408\u8ba1 \/ \u5b89\u88c5\u8d39\u5408\u8ba1<\/td><td>\u2014<\/td><td>43900<\/td><td>14300<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p class=\"muted\">\u65b9\u6848 A \u7a7a\u8c03\u603b\u8ba1 = \u8bbe\u5907\u00a543900 + \u5b89\u88c5\u00a514300 = <b>\u00a558200<\/b>\u3002<\/p>\n\n  <h4>\u65b9\u6848 B \u00b7 \u5c0a\u777f\u5168\u6548II\uff088.5\u6298\uff09\u2014 \u603b\u8ba1 \u00a578317<\/h4>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u540e\u8bbe\u5907<\/th><th>\u5b89\u88c5\u8d39<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u591a\u8054\u673a\u5916\u673a<\/td><td>RAS-224FSXPN5Q\uff0822.4kW\uff09<\/td><td>1<\/td><td>29300<\/td><td>24905<\/td><td>600<\/td><\/tr>\n      <tr><td>\u5185\u673a 71\u578b\uff08\u4e09\u7ba1\uff09<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1<\/td><td>5825<\/td><td>4951<\/td><td>1900<\/td><\/tr>\n      <tr><td>\u5185\u673a 40\u578b\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>RPIZ-40FSVNZ1QD\/PC<\/td><td>1<\/td><td>4800<\/td><td>4080<\/td><td>1600<\/td><\/tr>\n      <tr><td>\u5185\u673a 28\u578b\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>RPIZ-28FSVNZ1QD\/PC<\/td><td>1<\/td><td>4600<\/td><td>3910<\/td><td>1600<\/td><\/tr>\n      <tr><td>\u5185\u673a 18\u578b\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>RPIZ-18FSVNZ1QD\/PC<\/td><td>2<\/td><td>8850<\/td><td>7522<\/td><td>3200<\/td><\/tr>\n      <tr><td>\u5185\u673a 36\u578b\uff08\u4e24\u7ba1\u51c0\u5316\uff09<\/td><td>RPIZ-36FSVNZ1QD\/PC<\/td><td>1<\/td><td>4800<\/td><td>4080<\/td><td>1600<\/td><\/tr>\n      <tr><td>\u5185\u673a 45\u578b\uff08\u4e09\u7ba1\uff09<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>1<\/td><td>5563<\/td><td>4729<\/td><td>1900<\/td><\/tr>\n      <tr><td>\u8d1f\u4e00\u697c\u98ce\u7ba1\u673a<\/td><td>\u65e5\u7acb 72X1DQ1\uff087.2kW \u4e0d\u5e26\u6cf5\uff09<\/td><td>1<\/td><td>5500<\/td><td>5500<\/td><td>1800<\/td><\/tr>\n      <tr><td>WiFi \u7ebf\u63a7\u5668\uff08\u4e24\u7ba1\u51c0\u5316\u00d75+\u98ce\u7ba1\u673a\u00d71\uff09<\/td><td>PC-P1HVQA<\/td><td>6<\/td><td>600<\/td><td>3600<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u5f69\u5c4f\u7ebf\u63a7\u5668\uff08\u4e09\u7ba1\u00d72\uff09<\/td><td>\u65e5\u7acb\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td>2<\/td><td>420<\/td><td>840<\/td><td>\u2014<\/td><\/tr>\n      <tr class=\"total-row\"><td colspan=\"3\">\u8bbe\u5907\u6298\u540e\u5408\u8ba1 \/ \u5b89\u88c5\u8d39\u5408\u8ba1<\/td><td>\u2014<\/td><td>64117<\/td><td>14200<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p class=\"muted\">\u65b9\u6848 B \u7a7a\u8c03\u603b\u8ba1 = \u8bbe\u5907\u00a564117\uff08\u542b 2 \u53f0\u4e09\u7ba1\u5236\u5185\u673a\u5347\u7ea7\u5f69\u5c4f\u7ebf\u63a7\u5668 \u00a5420\/\u53f0\uff0c\u4e0d\u6253\u6298\uff09+ \u5b89\u88c5\u00a514200 = <b>\u00a578317<\/b>\u3002\u5c0a\u777f\u6bd4\u8212\u4eab\u521d\u6295\u9ad8 <b>\u00a520117<\/b>\u3002<\/p>\n\n  <h4>\u5730\u6696\u7cfb\u7edf\u62a5\u4ef7\u660e\u7ec6\uff08\u4e09\u65b9\u6848\uff09<\/h4>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u5730\u6696\u2460 \u603b\u63a799<\/th><th>\u5730\u6696\u2461 \u5206\u63a7119<\/th><th>\u5730\u6696\u2462 \u8282\u80fd169<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u9762\u79ef\u5957\u9910\uff08182.1\u33a1\uff09<\/td><td>\u00a518028<\/td><td>\u00a521670<\/td><td>\u00a530775<\/td><\/tr>\n      <tr><td>\u4e8c\u6b21\u7cfb\u7edf\uff08\u53d8\u9891\u6cf5+\u5206\u538b\u5668\uff09<\/td><td>\u00a53000<\/td><td>\u00a53000<\/td><td>\u00a53000<\/td><\/tr>\n      <tr><td>\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl 24kW<\/td><td>\u00a511715<\/td><td>\u00a511715<\/td><td>\u00a511715<\/td><\/tr>\n      <tr><td>\u51b7\u51dd\u7089\u5b89\u88c5<\/td><td>\u00a5600<\/td><td>\u00a5600<\/td><td>\u00a5600<\/td><\/tr>\n      <tr class=\"total-row\"><td>\u5730\u6696\u7cfb\u7edf\u603b\u8ba1<\/td><td>\u00a533343<\/td><td>\u00a536985<\/td><td>\u00a546090<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h4>\u70ed\u6c34\u7cfb\u7edf\u62a5\u4ef7\u660e\u7ec6<\/h4>\n  <table>\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u8bbe\u5907\uff08\u4f18\u60e0\u4ef7\uff09<\/th><th>\u5b89\u88c5\u8f85\u6750<\/th><th>\u5c0f\u8ba1<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u5730\u6696+\u4e00\u697c\u70ed\u6c34\u70ed\u6e90<\/td><td>\u5a01\u80fd\u56fd\u4ea7\u51b7\u51dd\u7089Introxl 24kW<\/td><td>\u00a511715<\/td><td>\u00a5600<\/td><td>\u00a512315<\/td><\/tr>\n      <tr><td>\u4e8c\u697c\u4e09\u697c\u70ed\u6c34\u70ed\u6e90<\/td><td>\u6797\u5185 24L \u96f6\u51b7\u6c34 RUS-R24E51G-CB<\/td><td>\u00a56499<\/td><td>\u00a5300<\/td><td>\u00a56799<\/td><\/tr>\n      <tr class=\"total-row\"><td colspan=\"4\">\u70ed\u6c34\u7cfb\u7edf\u65b0\u589e\u6295\u5165\uff08\u51b7\u51dd\u7089\u5df2\u542b\u4e8e\u5730\u6696\uff0c\u907f\u514d\u91cd\u590d\uff09<\/td><td>\u00a56799<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h4>\u5168\u5c4b\u7ec4\u5408\u603b\u6295\u5165\u5bf9\u6bd4<\/h4>\n  <table>\n    <thead><tr><th>\u7ec4\u5408<\/th><th>\u7a7a\u8c03<\/th><th>\u5730\u6696<\/th><th>\u6797\u5185\u70ed\u6c34<\/th><th>\u5168\u5c4b\u603b\u8ba1<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u8212\u4eab + \u5730\u6696\u246099 + \u6797\u5185<\/td><td>\u00a558200<\/td><td>\u00a533343<\/td><td>\u00a56799<\/td><td class=\"total-row\">\u00a598342<\/td><\/tr>\n      <tr><td>\u8212\u4eab + \u5730\u6696\u2461119 + \u6797\u5185<\/td><td>\u00a558200<\/td><td>\u00a536985<\/td><td>\u00a56799<\/td><td>\u00a5101984<\/td><\/tr>\n      <tr><td>\u8212\u4eab + \u5730\u6696\u2462169 + \u6797\u5185<\/td><td>\u00a558200<\/td><td>\u00a546090<\/td><td>\u00a56799<\/td><td>\u00a5111089<\/td><\/tr>\n      <tr><td>\u5c0a\u777f + \u5730\u6696\u246099 + \u6797\u5185<\/td><td>\u00a578317<\/td><td>\u00a533343<\/td><td>\u00a56799<\/td><td>\u00a5118459<\/td><\/tr>\n      <tr><td>\u5c0a\u777f + \u5730\u6696\u2461119 + \u6797\u5185<\/td><td>\u00a578317<\/td><td>\u00a536985<\/td><td>\u00a56799<\/td><td>\u00a5122101<\/td><\/tr>\n      <tr><td>\u5c0a\u777f + \u5730\u6696\u2462169 + \u6797\u5185<\/td><td>\u00a578317<\/td><td>\u00a546090<\/td><td>\u00a56799<\/td><td>\u00a5131206<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3 id=\"s3-20y\">3.7 20 \u5e74\u603b\u8d26\u5bf9\u6bd4\uff08\u8212\u4eab+\u5730\u6696\u2461 vs \u5c0a\u777f+\u5730\u6696\u2461\uff09<\/h3>\n  <p class=\"lead\">\u6210\u672c\u516c\u5f0f\uff1a<b>\u4f7f\u7528\u6210\u672c = (\u8d2d\u7f6e + \u7ef4\u4fdd + \u7528\u8d39) \u00f7 \u5bff\u547d\u5e74\u9650<\/b>\u3002\u7535\u4ef7\u53d6 0.55 \u5143\/\u5ea6\u3001\u71c3\u6c14 2.9 \u5143\/m\u00b3 \u4f30\u7b97\uff1b\u8bbe\u5907\u5bff\u547d\u6309 15 \u5e74\u8ba1\uff0c\u7b2c 15 \u5e74\u66f4\u6362\u3002\u5f15\u5bfc\u5173\u6ce8\u957f\u671f\u603b\u8d26\u800c\u975e\u4ec5\u521d\u6295\u8d44\u3002<\/p>\n  <div class=\"chart-box\" id=\"chart20y\"><\/div>\n\n  <div class=\"warn-line\">\u3010S3\uff1a\u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4\u8f93\u51fa\u5b8c\u6210\u3002\u8bf7\u786e\u8ba4\u5ba2\u6237\u662f\u5426\u7406\u89e3\u5404\u65b9\u6848\u65b9\u5411\u4e0e\u4ef7\u683c\u5bf9\u6bd4\u3002\u786e\u8ba4\u540e\u56de\u590d\u300c\u786e\u8ba4\u300d\uff0c\u6211\u5c06\u8f93\u51fa S4\uff1a\u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c\u3002\u3011<\/div>\n<\/section>\n\n<!-- ============ S4 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c ============ -->\n<section id=\"s4\">\n  <div class=\"sec-h\"><div class=\"num\">4<\/div><div><h2>S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/h2><div class=\"en\">Delivery & Service \u00b7 \u7cbe\u5de5\u7cbe\u5320\u9a8c\u6536\u6807\u51c6<\/div><\/div><\/div>\n  <div class=\"sec-nav\"><span class=\"sn-label\">\u672c\u8282\u5bfc\u822a<\/span><a href=\"#s4-stage\">\u516b\u5927\u9636\u6bb5<\/a><a href=\"#s4-service\">\u670d\u52a1\u627f\u8bfa<\/a><a href=\"#s4-gallery\">\u9a8c\u6536\u56fe\u96c6<\/a><\/div>\n\n  <div class=\"card note\">\n    <p>\u9f99\u8109\u6696\u901a \u00d7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u300c\u7cbe\u5de5\u7cbe\u5320\u300d\u65bd\u5de5\u9a8c\u6536\uff0c\u6309 <b>8 \u5927\u9636\u6bb5<\/b> \u6807\u51c6\u5316\u7ba1\u63a7\u3002\u5b8c\u6574\u89c4\u8303\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\" style=\"color:var(--info)\">\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303\uff08page_id=6342\uff09<\/a>\u3002\u9500\u552e\u51fa\u65b9\u6848\u65f6\u53ef\u5728\u672c\u9875\u5f15\u7528\u5b9e\u666f\u56fe\u96c6\uff08\u56fe\u7247\u5148\u4f20\u5a92\u4f53\u5e93\u53d6 URL\uff0c\u7981\u672c\u5730\u8def\u5f84\uff09\u3002<\/p>\n  <\/div>\n\n  <h3 id=\"s4-stage\">4.1 \u65bd\u5de5\u5b89\u88c5\u9a8c\u6536\u516b\u5927\u9636\u6bb5<\/h3>\n  <table>\n    <thead><tr><th>\u9636\u6bb5<\/th><th>\u5173\u952e\u63a7\u5236\u70b9<\/th><th>\u9a8c\u6536\u8bc1\u636e<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u2460 \u6750\u6599\u8fdb\u573a<\/td><td>\u5185\u5916\u673a\u8bbe\u5907\u3001\u94dc\u7ba1\u58c1\u539a\u3001\u54c1\u724c\u89c4\u683c\u9010\u4e00\u6838\u5bf9<\/td><td>\u578b\u53f7\u94ed\u724c\u62cd\u7167\u7559\u5e95<\/td><\/tr>\n      <tr><td>\u2461 \u5185\u673a\u5b89\u88c5\u8d70\u7ba1<\/td><td>\u53cc\u87ba\u6bcd+\u53cc\u51cf\u9707\u57ab\u56fa\u5b9a\uff1b\u7ba1\u8def\u6a2a\u5e73\u7ad6\u76f4<\/td><td>\u9690\u853d\u5de5\u7a0b\u7167\u7247<\/td><\/tr>\n      <tr><td>\u2462 \u51b7\u51dd\u6c34\u7ba1<\/td><td>\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\uff1b\u6807\u51c6\u653e\u5165\u5730\u6f0f\uff08\u7981\u63a5\u6c61\u6c34\u7ba1\uff09<\/td><td>\u6392\u6c34\u6d4b\u8bd5\u8bb0\u5f55<\/td><\/tr>\n      <tr><td>\u2463 \u94dc\u7ba1\u710a\u63a5<\/td><td>\u6c2e\u6c14\u4fdd\u62a4\u710a\uff0c\u9632\u5185\u58c1\u6c27\u5316\u710a\u6e23<\/td><td>\u710a\u63a5\u5de5\u827a\u8bb0\u5f55<\/td><\/tr>\n      <tr><td>\u2464 \u6c2e\u6c14\u4fdd\u538b<\/td><td>R410A \u7cfb\u7edf\u6253\u538b 4.15MPa\uff0c\u4fdd\u538b 24h<\/td><td>\u4fdd\u538b\u8868\u8bfb\u6570<\/td><\/tr>\n      <tr><td>\u2465 \u4e00\u671f\u9690\u853d\u9a8c\u6536<\/td><td>\u4e1a\u4e3b\/\u88c5\u4fee\/\u65bd\u5de5\u4e09\u65b9\u7b7e\u5b57<\/td><td>\u9a8c\u6536\u5355<\/td><\/tr>\n      <tr><td>\u2466 \u8c03\u8bd5<\/td><td>\u7535\u8111\u8054\u8c03\uff0c\u751f\u6210\u8fd0\u884c\u62a5\u544a<\/td><td>\u8fd0\u884c\u62a5\u544a<\/td><\/tr>\n      <tr><td>\u2467 \u6559\u5b66\u4ea4\u4ed8<\/td><td>\u7ebf\u63a7\u5668\u64cd\u4f5c\/\u7ef4\u62a4\/\u552e\u540e\u8bf4\u660e<\/td><td>\u4ea4\u4ed8\u786e\u8ba4\u5355<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3 id=\"s4-service\">4.2 \u670d\u52a1\u627f\u8bfa<\/h3>\n  <div class=\"pill\">\n    <div class=\"p\">\u987e\u95ee <b>\u9ec4\u52c7\uff0813 \u5e74\uff09<\/b>\ud83d\udcde 15828489188<\/div>\n    <div class=\"p\">\u65e5\u7acb\u6574\u673a <b>\u5b98\u65b9\u8d28\u4fdd<\/b><\/div>\n    <div class=\"p\">\u5a01\u80fd\u51b7\u51dd\u7089 <b>\u8d28\u4fdd + \u56fd\u8865<\/b><\/div>\n    <div class=\"p\">\u5730\u6696\u2462 <b>\u4e09\u65b9\u8054\u4fdd<\/b><\/div>\n    <div class=\"p\">10 \u5e74 <b>\u80fd\u8017\u8ddf\u8e2a\u6863\u6848<\/b><\/div>\n  <\/div>\n  <div class=\"ok-line\"><b>\u5b89\u88c5\u552e\u540e\uff1a<\/b>\u4e8c\u6b21\u7cfb\u7edf\uff08\u589e\u538b\u6cf5+\u6c34\u529b\u5206\u538b\u5668\uff09\u8bbe\u5907\u95f4\u9884\u7559\u5230\u4f4d\uff1b\u8d1f\u4e00\u697c 72X1DQ1 \u98ce\u7ba1\u673a\u540a\u9876\u51c0\u7a7a \u2265200mm \u5e76\u9884\u7559\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\uff1b\u5916\u673a\u79bb\u5899 \u226530cm \u901a\u98ce\u3002\u4ea4\u4ed8\u540e\u7eb3\u5165 S5 \u6863\u6848\u4eea\u8868\u76d8\u957f\u671f\u8ddf\u8e2a\u3002<\/div>\n\n  <h4>\u7a7a\u8c03\u7cfb\u7edf\u8bbe\u8ba1\u56fe\u7eb8\uff08\u901a\u7528\u793a\u610f\uff09<\/h4>\n  <div class=\"gallery-note\">\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u8bbe\u8ba1\u901a\u7528\u56fe\u7eb8\u793a\u4f8b\uff0c\u5bf9\u5e94\u5206\u6b67\u7ba1\u8def\u3001\u65bd\u5de5\u5e73\u9762\u4e0e\u63a7\u5236\u5668\u7cfb\u7edf\uff0c\u4f9b\u65b9\u6848\u8bbe\u8ba1\u53c2\u8003\u3002<\/div>\n  <div class=\"gallery\">\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dnfqpmt.jpg\" alt=\"\u4e2d\u592e\u7a7a\u8c03\u5927\u5206\u6b67\u5e73\u9762\u56fe\"><figcaption><span class=\"idx\">\u8bbe1<\/span>\u5927\u5206\u6b67\u5e73\u9762\u56fe<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dnsgpmt.jpg\" alt=\"\u4e2d\u592e\u7a7a\u8c03\u5927\u65bd\u5de5\u5e73\u9762\u56fe\"><figcaption><span class=\"idx\">\u8bbe2<\/span>\u5927\u65bd\u5de5\u5e73\u9762\u56fe<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dnecxtmrdh-boxldkzjxt-2.jpg\" alt=\"\u4e2d\u592e\u7a7a\u8c03\u63a7\u5236\u5668\u7cfb\u7edf\u56fe\"><figcaption><span class=\"idx\">\u8bbe3<\/span>\u63a7\u5236\u5668\u7cfb\u7edf\u56fe<\/figcaption><\/figure>\n  <\/div>\n\n  <style>\n  .gallery{display:grid;grid-template-columns:repeat(auto-fill,minmax(178px,1fr));gap:12px;margin:14px 0 4px}\n  .gallery figure{margin:0;border:1px solid var(--border);border-radius:10px;overflow:hidden;background:var(--bg-card);box-shadow:var(--shadow-sm);cursor:zoom-in;transition:transform .2s,box-shadow .2s}\n  .gallery figure:hover{transform:translateY(-3px);box-shadow:0 6px 18px rgba(0,0,0,.14)}\n  .gallery img{width:100%;height:142px;object-fit:cover;display:block;background:#eef2f6}\n  .gallery figcaption{padding:8px 10px;font-size:12.5px;color:var(--text);line-height:1.42}\n  .gallery figcaption .idx{color:var(--primary);font-weight:700;margin-right:4px}\n  .gallery-note{font-size:12.5px;color:var(--muted);margin:2px 0 10px}\n  .lightbox{position:fixed;inset:0;background:rgba(10,20,30,.92);display:none;align-items:center;justify-content:center;z-index:9999;flex-direction:column;padding:24px;cursor:zoom-out}\n  .lightbox.on{display:flex}\n  .lightbox img{max-width:92vw;max-height:80vh;border-radius:8px;box-shadow:0 10px 40px rgba(0,0,0,.5)}\n  .lightbox .cap{color:#fff;margin-top:14px;font-size:15px;text-align:center}\n  .lightbox .cls{position:absolute;top:16px;right:26px;color:#fff;font-size:32px;cursor:pointer;line-height:1}\n  <\/style>\n\n  <h3 id=\"s4-gallery\">4.3 \u65bd\u5de5\u5b9e\u666f\u9a8c\u6536\u56fe\u96c6<\/h3>\n  <div class=\"gallery-note\">\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u7c7b\u522b\u5885\u9879\u76ee\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u666f\uff0c\u5bf9\u5e94 4.1 \u516b\u5927\u9636\u6bb5\u63a7\u5236\u70b9\u3002\u70b9\u51fb\u56fe\u7247\u53ef\u653e\u5927\u67e5\u770b\u3002<\/div>\n\n  <h4>\u56fe\u96c6\u4e00 \u00b7 \u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5b9e\u666f\uff08\u7cbe\u5de5\u7cbe\u5320\uff09<\/h4>\n  <div class=\"gallery\">\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\"><figcaption><span class=\"idx\">01<\/span>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\"><figcaption><span class=\"idx\">02<\/span>\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c\"><figcaption><span class=\"idx\">03<\/span>\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\"><figcaption><span class=\"idx\">04<\/span>\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xhmpqk.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\"><figcaption><span class=\"idx\">05<\/span>\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-frdl.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f\"><figcaption><span class=\"idx\">06<\/span>\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\"><figcaption><span class=\"idx\">07<\/span>\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\"><figcaption><span class=\"idx\">08<\/span>\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6c2e\u6c14\u4fdd\u538b\u8868\u8bfb\u6570\"><figcaption><span class=\"idx\">09<\/span>\u6c2e\u6c14\u4fdd\u538b\u8868\u8bfb\u6570<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\"><figcaption><span class=\"idx\">10<\/span>\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u73b0\u573a\u8bbe\u5907\u6559\u5b66\u4ea4\u4ed8\"><figcaption><span class=\"idx\">11<\/span>\u73b0\u573a\u8bbe\u5907\u6559\u5b66\u4ea4\u4ed8<\/figcaption><\/figure>\n  <\/div>\n\n  <h4>\u56fe\u96c6\u4e8c \u00b7 \u4e2d\u592e\u7a7a\u8c03\u6807\u51c6\u5b89\u88c5\u5de5\u827a<\/h4>\n  <div class=\"gallery\">\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba11\"><figcaption><span class=\"idx\">01<\/span>\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba1 \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd2.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba12\"><figcaption><span class=\"idx\">02<\/span>\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba1 \u2461<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5ba4\u5185\u673a\u6807\u51c6\u5b89\u88c5\"><figcaption><span class=\"idx\">03<\/span>\u5ba4\u5185\u673a\u6807\u51c6\u5b89\u88c5 \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz3.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5ba4\u5185\u673a\u6807\u51c6\u5b89\u88c5\u7ec6\u8282\"><figcaption><span class=\"idx\">04<\/span>\u5ba4\u5185\u673a\u6807\u51c6\u5b89\u88c5 \u2461<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz4.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5ba4\u5185\u673a\u6807\u51c6\u5b89\u88c5\u7ec6\u8282\"><figcaption><span class=\"idx\">05<\/span>\u5ba4\u5185\u673a\u6807\u51c6\u5b89\u88c5 \u2462<\/figcaption><\/figure>\n  <\/div>\n\n  <h4>\u56fe\u96c6\u4e09 \u00b7 \u5730\u6696\u6807\u51c6\u65bd\u5de5\u5de5\u827a<\/h4>\n  <div class=\"gallery\">\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe1\"><figcaption><span class=\"idx\">01<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-02.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe2\"><figcaption><span class=\"idx\">02<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2461<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-03.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe3\"><figcaption><span class=\"idx\">03<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2462<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-04.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe4\"><figcaption><span class=\"idx\">04<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2463<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-05.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe5\"><figcaption><span class=\"idx\">05<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2464<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-dnpg-01.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe6\"><figcaption><span class=\"idx\">06<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2465<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-dnpg-02.jpg\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe7\"><figcaption><span class=\"idx\">07<\/span>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe \u2466<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-jsbps.jpg\" alt=\"\u5730\u6696\u96c6\u6c34\u5668\u4fdd\u6e29\"><figcaption><span class=\"idx\">08<\/span>\u5730\u6696\u96c6\u6c34\u5668\u4fdd\u6e29<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-01.jpg\" alt=\"\u5730\u6696\u94fa\u6cd5\u8bf4\u660e1\"><figcaption><span class=\"idx\">09<\/span>\u5730\u6696\u94fa\u6cd5\u8bf4\u660e \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-02.jpg\" alt=\"\u5730\u6696\u94fa\u6cd5\u8bf4\u660e2\"><figcaption><span class=\"idx\">10<\/span>\u5730\u6696\u94fa\u6cd5\u8bf4\u660e \u2461<\/figcaption><\/figure>\n  <\/div>\n\n  <div class=\"warn-line\">\u3010S4\uff1a\u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c\u8f93\u51fa\u5b8c\u6210\u3002\u8bf7\u786e\u8ba4\u5ba2\u6237\u662f\u5426\u8ba4\u53ef\u65bd\u5de5\u6807\u51c6\u4e0e\u670d\u52a1\u627f\u8bfa\u3002\u786e\u8ba4\u540e\u56de\u590d\u300c\u786e\u8ba4\u300d\uff0c\u6211\u5c06\u8f93\u51fa S5\uff1a\u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3\u3002\u3011<\/div>\n\n  <div class=\"lightbox\" id=\"lightbox\"><span class=\"cls\">\u00d7<\/span><img decoding=\"async\" src=\"\" alt=\"\u65bd\u5de5\u5b9e\u666f\u653e\u5927\u56fe\"><div class=\"cap\"><\/div><\/div>\n  <script>\n  (function(){\n    var lb=document.getElementById('lightbox');\n    if(!lb) return;\n    var lbimg=lb.querySelector('img'), lbcap=lb.querySelector('.cap');\n    document.querySelectorAll('.gallery figure').forEach(function(f){\n      f.addEventListener('click',function(){\n        var im=f.querySelector('img'), cp=f.querySelector('figcaption');\n        lbimg.src=im.getAttribute('src'); lbcap.textContent=cp?cp.textContent:'';\n        lb.classList.add('on');\n      });\n    });\n    lb.addEventListener('click',function(){lb.classList.remove('on'); lbimg.src='';});\n  })();\n  <\/script>\n<\/section>\n\n<!-- ============ S5 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3 ============ -->\n<section id=\"s5\">\n  <div class=\"sec-h\"><div class=\"num\">5<\/div><div><h2>S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<\/h2><div class=\"en\">Validation & Iteration \u00b7 \u6863\u6848\u4eea\u8868\u76d8 + AI \u9a8c\u8bc1<\/div><\/div><\/div>\n  <div class=\"sec-nav\"><span class=\"sn-label\">\u672c\u8282\u5bfc\u822a<\/span><a href=\"#s5-file\">\u6863\u6848\u4eea\u8868\u76d8<\/a><a href=\"#s5-radar\">\u516d\u7ef4\u96f7\u8fbe<\/a><a href=\"#s5-ai\">AI\u9a8c\u8bc1<\/a><a href=\"#s5-case\">\u6848\u4f8b\u53c2\u7167<\/a><\/div>\n\n  <h3 id=\"s5-file\">5.1 \u5ba2\u6237\u6210\u529f\u6863\u6848\u4eea\u8868\u76d8\uff08\u4ea4\u4ed8\u540e\u5efa\u7acb\uff09<\/h3>\n  <div class=\"card\">\n    <p><b>\u6863\u6848\u5305\u542b\uff1a<\/b>\u65bd\u5de5\u5168\u6d41\u7a0b\u7167\u7247 \/ \u8bbe\u5907\u6e05\u5355\u9a8c\u6536\u5355 \/ 10 \u5e74\u80fd\u8017\u8ddf\u8e2a \/ \u552e\u540e\u8bb0\u5f55 \/ \u5e74\u5ea6\u80fd\u8017\u62a5\u544a\u3002<\/p>\n    <p class=\"lead\" style=\"margin-top:8px\">10 \u5e74\u8ddf\u8e2a\u56db\u8def\u6807\uff1a\u7b2c 1 \u5e74\u521d\u59cb\u6027\u80fd\u6863\u6848 \u2192 \u7b2c 3 \u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a \u2192 \u7b2c 5 \u5e74\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad \u2192 \u7b2c 10 \u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u3002\u540c\u6237\u578b\u6863\u6848\u53ef\u4f18\u5148\u5f15\u7528\u6210\u90fd\u522b\u5885\u7c7b\u6848\u4f8b\u3002<\/p>\n  <\/div>\n\n  <h3 id=\"s5-radar\">5.2 \u7a7a\u8c03\u53cc\u65b9\u6848 \u00b7 \u516d\u7ef4\u8bc4\u5206\u96f7\u8fbe\uff08\u6848\u4f8b\u9a8c\u8bc1\u89c6\u89d2\uff09<\/h3>\n  <div class=\"chart-box\" id=\"chartRadar\"><\/div>\n  <p class=\"muted\">\u56fe\uff1a\u65b9\u6848 A\uff08\u8212\u4eab\uff09\u4e0e\u65b9\u6848 B\uff08\u5c0a\u777f\u5168\u6548II\uff09\u516d\u7ef4\u5ea6\u7efc\u5408\u8bc4\u5206\u3002\u5c0a\u777f\u5728\u8212\u9002\u5ea6\/\u8fd0\u884c\u8d39\u7ef4\u5ea6\u663e\u8457\u9886\u5148\uff0c\u8212\u4eab\u5728\u521d\u6295\u8d44\/\u7ef4\u62a4\u8d39\u9886\u5148\uff0c\u7a33\u5b9a\u6027\u4e0e\u5bff\u547d\u6301\u5e73\u3002<\/p>\n\n  <h3 id=\"s5-ai\">5.3 AI \u9a8c\u8bc1\u6e05\u5355<\/h3>\n  <table>\n    <thead><tr><th>\u9a8c\u8bc1\u7c7b\u522b<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u8bca\u65ad\u9a8c\u8bc1<\/td><td>\u591a\u5c42\u522b\u5885\u5206\u533a\u63a7\u6e29\u3001\u8fdc\u7aef\u70ed\u6c34\u3001\u5927\u9762\u79ef\u5730\u6696\u4e8c\u6b21\u7cfb\u7edf\u2014\u2014\u8bca\u65ad\u4e0e\u914d\u7f6e\u5339\u914d \u2713<\/td><\/tr>\n      <tr><td>\u529f\u7387\u5339\u914d\u9a8c\u8bc1<\/td><td>22.4kW \u5916\u673a\u914d 25.6kW \u5185\u673a\uff0c\u8d85\u914d\u7387 114%\uff08\u65e5\u7acb\u4e0a\u9650 130%\uff09\u2713<\/td><\/tr>\n      <tr><td>\u80fd\u8017\u9a8c\u8bc1<\/td><td>\u5e38\u4f4f 2 \u4eba\uff0c\u90e8\u5206\u65f6\u6bb5\u4f7f\u7528\uff0c\u7cfb\u7edf\u9ad8\u6548\uff1b\u5c0a\u777f\u6e29\u6e7f\u53cc\u63a7\u957f\u671f\u66f4\u7701 \u2713<\/td><\/tr>\n      <tr><td>\u56fd\u6807\u9a8c\u8bc1<\/td><td>\u51b7\u8d1f\u8377 160W\/\u33a1\u3001\u70ed\u8d1f\u8377 200W\/\u33a1\u3001\u8d85\u914d\u7387 50%~130% \u5747\u5408\u89c4 \u2713<\/td><\/tr>\n      <tr><td>\u6848\u4f8b\u9a8c\u8bc1<\/td><td>\u6210\u90fd\u522b\u5885\u00b7\u65e5\u7acb\u591a\u8054\u673a+\u5a01\u80fd\u5730\u6696\u7c7b\u6848\u53ef\u53c2\u7167\uff08\u8be6\u89c1\u6848\u4f8b\u5e93 page_id=2297\uff09\u2713<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3 id=\"s5-case\">5.4 \u540c\u6237\u578b\u6848\u4f8b\u53c2\u7167 &amp; \u4ea7\u54c1\u8d44\u6e90<\/h3>\n  <div class=\"links\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><b>\u5ba2\u6237\u6848\u4f8b\u5e93<\/b><span>\u540c\u6237\u578b \/ \u540c\u9762\u79ef \/ \u540c\u7cfb\u7edf \u5b9e\u666f\u53c2\u8003\uff0c\u4f18\u5148\u5339\u914d\u6210\u90fd\u522b\u5885\u7c7b<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\"><b>\u7cbe\u5de5\u7cbe\u5320\u9a8c\u6536\u89c4\u8303<\/b><span>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u6807\u51c6\u56fe\u96c6\uff08S4 \u5f15\u7528\uff09<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\"><b>\u65e5\u7acb\u8212\u4eab\u4ea7\u54c1\u624b\u518c<\/b><span>\u65b9\u6848A\uff08\u8212\u4eab\uff09\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\u4e0e\u53c2\u6570<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\"><b>\u65e5\u7acb\u5c0a\u777f\u5168\u6548II\u8be6\u60c5<\/b><span>\u65b9\u6848B\uff08\u5c0a\u777f\uff09\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u65d7\u8230\u4ecb\u7ecd<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=4326\" target=\"_blank\"><b>\u65e5\u7acb\u98ce\u7ba1\u673a\u8be6\u60c5<\/b><span>\u8d1f\u4e00\u697c72X1DQ1\u540c\u7cfb\u5217\u4ea7\u54c1<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2489\" target=\"_blank\"><b>\u6797\u5185\u58c1\u6302\u7089\u5168\u7cfb\u5217<\/b><span>\u4e8c\u4e09\u697c\u6797\u518524L\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\u6240\u5c5e\u7cfb\u5217<\/span><\/a>\n  <\/div>\n  <p class=\"muted\">\u8bf4\u660e\uff1a\u672c\u6848\u6309\u300c\u540c\u6237\u578b &gt; \u540c\u9762\u79ef &gt; \u540c\u7cfb\u7edf\u300d\u4f18\u5148\u7ea7\u5f15\u7528\u771f\u5b9e\u6848\u4f8b\uff1b\u5177\u4f53\u6848\u4f8b\u8131\u654f\u540e\u4e8e\u6848\u4f8b\u5e93\u5448\u73b0\uff0c\u672c\u65b9\u6848\u4e66\u4e0d\u5806\u780c\u65e0\u5173\u6848\u4f8b\u3002<\/p>\n\n  <div class=\"warn-line\">\u3010S5\uff1a\u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3\u8f93\u51fa\u5b8c\u6210\u3002\u4e94\u5927\u6b65\u9aa4\uff08S1-S5\uff09\u5168\u90e8\u8f93\u51fa\u5b8c\u6bd5\u3002\u8bf7\u9500\u552e\u5224\u65ad\u662f\u5426\u8fdb\u5165\u7b7e\u7ea6\u73af\u8282\u3002\u3011<\/div>\n<\/section>\n\n<!-- ============ \u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97 ============ -->\n<section id=\"auth-store\">\n  <div class=\"sec-h\"><div class=\"num\">\ud83c\udfc5<\/div><div><h2>\u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97<\/h2><div class=\"en\">Authorization &amp; Stores \u00b7 \u5b98\u65b9\u6388\u6743 \u00b7 \u5b9e\u5730\u53ef\u8bbf<\/div><\/div><\/div>\n  <p class=\"lead\">\u9f99\u8109\u6696\u901a\u4e3a\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546\uff0c\u4ee5\u4e0b\u4e3a\u76f8\u5173\u6388\u6743\u8bc1\u4e66\uff1b\u65b9\u6848\u54a8\u8be2\u4e0e\u8bbe\u5907\u9a8c\u6536\u53ef\u81f3\u9f99\u8109\u6696\u901a\u6210\u90fd\u4e24\u5e97\u5b9e\u5730\u529e\u7406\u3002<\/p>\n\n  <h3>\u54c1\u724c\u6388\u6743\u8bc1\u4e66<\/h3>\n  <div class=\"cert-grid\">\n    <figure>\n      <div class=\"cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u95002026\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500 2026<\/figcaption>\n    <\/figure>\n  <\/div>\n\n  <h3>\u9f99\u8109\u6696\u901a\u95e8\u5e97\u5b9e\u666f<\/h3>\n  <div class=\"store-grid\">\n    <figure>\n      <div class=\"store-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('img-fail')\"><\/div>\n      <figcaption>\n        <div class=\"store-name\">\u5357\u5bcc\u68ee\u5e97<\/div>\n        <div class=\"addr\">\ud83d\udccd \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/div>\n        <div class=\"addr\">\u260e 15828489188\uff08\u9ec4\u52c7\uff09<\/div>\n      <\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"store-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('img-fail')\"><\/div>\n      <figcaption>\n        <div class=\"store-name\">\u5317\u5bcc\u68ee\u5e97<\/div>\n        <div class=\"addr\">\ud83d\udccd \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/div>\n        <div class=\"addr\">\u260e 15828489188\uff08\u9ec4\u52c7\uff09<\/div>\n      <\/figcaption>\n    <\/figure>\n  <\/div>\n  <p class=\"muted\">\u8bf4\u660e\uff1a\u6388\u6743\u8bc1\u4e66\u4e0e\u95e8\u5e97\u5b9e\u666f\u5747\u53d6\u81ea\u9f99\u8109\u6696\u901a\u5a92\u4f53\u5e93\uff08\u5177\u6b63\u5f0f URL\uff0c\u975e\u672c\u5730\u8def\u5f84\uff09\u3002\u5982\u4e2a\u522b\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d\uff0c\u8bf7\u7528\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\u67e5\u770b\u3002<\/p>\n<\/section>\n\n<!-- ============ FAQ ============ -->\n<section id=\"faq\">\n  <div class=\"sec-h\"><div class=\"num\">?<\/div><div><h2>\u5e38\u89c1\u95ee\u9898\uff08\u5ba2\u6237\u89c6\u89d2\uff09<\/h2><div class=\"en\">FAQ<\/div><\/div><\/div>\n  <div class=\"faq-item\"><div class=\"faq-q\">Q1\uff1a\u6210\u90fd\u5408\u9662\u522b\u5885\u7528\u4e00\u62d6\u4e03\u4e2d\u592e\u7a7a\u8c03\uff0c\u8d85\u914d\u7387 114% \u5b89\u5168\u5417\uff1f<\/div><div class=\"faq-a\">\u65e5\u7acb\u591a\u8054\u673a\u5141\u8bb8\u8d85\u914d\u4e0a\u9650 130%\uff0c\u672c\u65b9\u6848 22.4kW \u5916\u673a\u914d 25.6kW \u5185\u673a\uff0c\u8d85\u914d\u7387 114% \u5904\u4e8e\u5b89\u5168\u5408\u7406\u533a\u95f4\uff1b\u4e14\u5e38\u4f4f\u4ec5 2 \u4eba\uff0c\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u7cfb\u7edf\u9ad8\u6548\u8fd0\u884c\u3002<\/div><\/div>\n  <div class=\"faq-item\"><div class=\"faq-q\">Q2\uff1a\u8212\u4eab\u548c\u5c0a\u777f\u5168\u6548II \u600e\u4e48\u9009\uff1f<\/div><div class=\"faq-a\">\u8212\u4eab\u5b9a\u4f4d\u7ecf\u6d4e\u5b9e\u7528\uff0c8 \u6298\u540e\u521d\u6295\u66f4\u4f4e\uff1b\u5c0a\u777f\u5168\u6548II \u652f\u6301\u6e29\u6e7f\u53cc\u63a7\u4e0e\u4e09\u7ba1\u5236\u72ec\u7acb\u9664\u6e7f\uff08\u4e8c\u697c\u4e09\u697c\u914d\u7f6e\uff09\uff0c\u6210\u90fd\u9ad8\u6e7f\u73af\u5883\u4e0b\u8212\u9002\u5ea6\u4e0e\u957f\u671f\u80fd\u8017\u66f4\u4f18\uff0c\u4f46\u521d\u6295\u9ad8\u7ea6 2 \u4e07\u3002\u5165\u4f4f\u7387\u9ad8\u3001\u5bf9\u6e7f\u5ea6\u654f\u611f\u9009\u5c0a\u777f\uff0c\u9884\u7b97\u4f18\u5148\u9009\u8212\u4eab\u3002<\/div><\/div>\n  <div class=\"faq-item\"><div class=\"faq-q\">Q3\uff1a\u5730\u6696 99\/119\/169 \u4e09\u6863\u5dee\u5728\u54ea\uff1f<\/div><div class=\"faq-a\">99 \u4e3a\u5e02\u573a\u901a\u914d\u603b\u63a7\uff08\u4f1f\u661f\u603b\u63a7\uff09\uff1b119 \u4e3a\u5e02\u573a\u901a\u914d\u5206\u63a7\uff08\u66fc\u745e\u5fb7\u5206\u63a7\uff0c\u53ef\u5206\u5c42\u63a7\u6e29\uff09\uff1b169 \u4e3a\u516c\u53f8\u8282\u80fd\u8bbe\u8ba1\uff0832-20 \u7ba1 + \u6d41\u91cf\u63d0\u5347 + WiFi \u8054\u52a8 + \u4e09\u65b9\u8054\u4fdd\uff09\u3002182\u33a1 \u522b\u5885\u63a8\u8350 119 \u5206\u63a7\u8d77\u6b65\u3002<\/div><\/div>\n  <div class=\"faq-item\"><div class=\"faq-q\">Q4\uff1a\u4e3a\u4ec0\u4e48\u70ed\u6c34\u8981\u505a\u5206\u79bb\u5f0f\uff08\u5a01\u80fd + \u6797\u5185\uff09\uff1f<\/div><div class=\"faq-a\">\u5730\u6696\u4e0e\u4e00\u697c\u751f\u6d3b\u70ed\u6c34\u7531\u5a01\u80fd\u51b7\u51dd\u7089\u7edf\u4e00\u4f9b\u5e94\uff1b\u4e8c\u697c\u4e09\u697c\u8ddd\u79bb\u8fdc\uff0c\u5355\u72ec\u7528\u6797\u5185 24L \u96f6\u51b7\u6c34\u71c3\u6c14\u70ed\u6c34\u5668\u5e76\u505a\u56de\u6c34\u7ba1\u5faa\u73af\uff0c\u4fdd\u8bc1\u8fdc\u7aef\u5373\u5f00\u5373\u70ed\uff0c\u4e24\u7cfb\u7edf\u4e92\u4e0d\u5e72\u6270\u3002<\/div><\/div>\n  <div class=\"faq-item\"><div class=\"faq-q\">Q5\uff1a182\u33a1 \u5730\u6696\u7528 24kW \u51b7\u51dd\u7089\u591f\u5417\uff1f<\/div><div class=\"faq-a\">\u6309\u6210\u90fd\u522b\u5885\u5b9e\u9645\u70ed\u8d1f\u8377\u7ea6 100-130W\/\u33a1\uff0c182\u33a1 \u7ea6 18-24kW\uff0c24kW \u51b7\u51dd\u7089\u53ef\u8986\u76d6\uff1b\u914d\u5408\u4e8c\u6b21\u7cfb\u7edf\u4e0e\u5206\u533a\u63a7\u5236\u66f4\u7a33\u59a5\uff0c\u6700\u7ec8\u4ee5\u73b0\u573a\u8d1f\u8377\u590d\u6838\u4e3a\u51c6\u3002<\/div><\/div>\n<\/section>\n\n<!-- ============ \u5185\u94fe ============ -->\n<section id=\"links\">\n  <div class=\"sec-h\"><div class=\"num\">\ud83d\udd17<\/div><div><h2>\u5ef6\u4f38\u9605\u8bfb \u00b7 \u9f99\u8109\u6696\u901a\u8d44\u6e90<\/h2><div class=\"en\">Internal Links<\/div><\/div><\/div>\n  <div class=\"card note\" style=\"margin-bottom:14px\">\n    <p><b>\ud83d\udccc \u4ea7\u54c1\u8be6\u60c5\u9875\uff1a<\/b>\u70b9\u51fb\u4ee5\u4e0b\u94fe\u63a5\u53ef\u67e5\u770b\u9f99\u8109\u6696\u901a\u5b98\u7f51\u4e0a\u672c\u65b9\u6848\u6d89\u53ca\u5404\u4ea7\u54c1\u7684\u5b8c\u6574\u4ecb\u7ecd\u624b\u518c\u3001\u53c2\u6570\u4e0e\u4ef7\u683c\u3002<\/p>\n  <\/div>\n  <div class=\"links\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\"><b>\u65e5\u7acb EX-\u8212\u4eab \u5b8c\u6574\u4ea7\u54c1\u624b\u518c<\/b><span>\u5916\u673a\/\u5185\u673a\u5168\u7cfb\u53c2\u6570 \u00b7 \u6838\u5fc3\u6280\u672f \u00b7 \u9009\u578b\u6307\u5357<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2782\" target=\"_blank\"><b>\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u7cfb\u5217\uff08180\/200\/224\uff09<\/b><span>\u672c\u65b9\u6848\u6240\u7528 RAS-224HRNBQ \u6240\u5c5e\u7cfb\u5217\u8be6\u60c5<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\"><b>\u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u4ea7\u54c1\u8be6\u60c5\u9875<\/b><span>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 \u00b7 \u5168\u98ce\u8def\u51c0\u5316 \u00b7 \u4e09\u8054\u4f9b<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=4326\" target=\"_blank\"><b>\u65e5\u7acbUX Pro \u98ce\u7ba1\u673a<\/b><span>\u8d1f\u4e00\u697c72X1DQ1\u540c\u7cfb\u5217 \u00b7 \u8d85\u8584\u9759\u97f3<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2489\" target=\"_blank\"><b>\u6797\u5185 Rinnai \u58c1\u6302\u7089\u5168\u7cfb\u5217<\/b><span>\u767e\u5e74\u65e5\u672c\u54c1\u724c \u00b7 \u96f6\u51b7\u6c34\u6280\u672f \u00b7 \u6210\u90fd\u5206\u9500<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=916\" target=\"_blank\"><b>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u54c1\u724c\u53ca\u5168\u7cfb\u4ea7\u54c1<\/b><span>\u8212\u4eab\/\u5c0a\u777f\/\u6c34\u5885\u9002\/VAMmini \u5168\u7cfb\u5217\u4e00\u89c8<\/span><\/a>\n  <\/div>\n  <div class=\"card note\" style=\"margin-top:18px;margin-bottom:14px\">\n    <p><b>\ud83d\udcda \u77e5\u8bc6\u5e93\u4e0e\u8d44\u6e90\uff1a<\/b>\u6280\u672f\u767d\u76ae\u4e66\u3001\u65bd\u5de5\u89c4\u8303\u3001\u6848\u4f8b\u5e93\u4e0e\u65b9\u6848\u6307\u5357\u3002<\/p>\n  <\/div>\n  <div class=\"links\">\n    <a href=\"https:\/\/longmai-nt.com\/\" target=\"_blank\"><b>\u9f99\u8109\u6696\u901a\u5b98\u7f51<\/b><span>\u6210\u90fd\u672c\u5730\u51b7\u6696\u4e00\u4f53\u5316\u96c6\u6210\u670d\u52a1\u5546<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><b>\u5ba2\u6237\u6848\u4f8b\u5e93<\/b><span>\u540c\u6237\u578b\/\u540c\u7cfb\u7edf\u5b9e\u666f\u53c2\u8003 \u00b7 200+\u771f\u5b9e\u5ba2\u6237<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\"><b>\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303<\/b><span>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u6807\u51c6\u56fe\u96c6 \u00b7 \u516b\u5927\u9636\u6bb5<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/fluorine.html\" target=\"_blank\"><b>\u6c1f\u7cfb\u7edf\u767d\u76ae\u4e66<\/b><span>\u65e5\u7acb\u53d8\u9891\u6280\u672f \u00b7 \u591a\u8054\u673a\u539f\u7406 \u00b7 \u51b7\u5a92\u4e0e\u538b\u7f29\u673a<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/floor-heating.html\" target=\"_blank\"><b>\u5730\u6696\/\u6696\u6c14\u7247\/\u70ed\u6c34\u767d\u76ae\u4e66<\/b><span>\u58c1\u6302\u7089\u51b7\u51dd\u6280\u672f \u00b7 \u5730\u6696\u65bd\u5de5 \u00b7 \u4e8c\u6b21\u7cfb\u7edf\u8bbe\u8ba1<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/water.html\" target=\"_blank\"><b>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u767d\u76ae\u4e66<\/b><span>\u5929\u6c34\u5730\u6c34 \u00b7 \u7f13\u51b2\u6c34\u7bb1 \u00b7 \u4e00\/\u4e8c\u6b21\u7cfb\u7edf<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=675\" target=\"_blank\"><b>\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66<\/b><span>\u6e29\u6e7f\u5ea6\u4e0e\u4eba\u4f53\u8212\u9002 \u00b7 \u7a7a\u6c14\u54c1\u8d28 \u00b7 \u566a\u97f3\u7814\u7a76<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=649\" target=\"_blank\"><b>\u7b56\u7565\u5361\u4e3b\u5e93<\/b><span>\u6309\u573a\u666f\u5206\u7c7b\u7684\u9500\u552e\u7b56\u7565\u4e0e\u8bbe\u8ba1\u51b3\u7b56\u652f\u6301<\/span><\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1267\" target=\"_blank\"><b>\u9f99\u8109\u6696\u901a\u6280\u80fd\u5e93<\/b><span>\u6307\u4ee40-6 \u00b7 \u767d\u76ae\u4e66 \u00b7 \u7b56\u7565\u5361 \u00b7 \u5168\u8d44\u6e90\u7d22\u5f15<\/span><\/a>\n  <\/div>\n<\/section>\n\n<footer>\n  <p>\u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7\uff0813 \u5e74\u884c\u4e1a\u7ecf\u9a8c\uff09\ud83d\udcde <span class=\"gold\">15828489188<\/span><\/p>\n  <p style=\"margin-top:8px;opacity:.85\">\u672c\u65b9\u6848\u4e66\u6309 GEO \u5de5\u4f5c\u6d41\u603b\u89c8 V2.0 \u4e94\u6b65\u6cd5\uff08S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807 \/ S2 \u9700\u6c42\u75db\u70b9\u8bca\u65ad \/ S3 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4 \/ S4 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c \/ S5 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3\uff09\u7f16\u5236\uff0c\u62a5\u4ef7\u57fa\u4e8e\u9f99\u8109\u6696\u901a 2026 \u5e74 V5.0 \u4ef7\u683c\u6307\u4ee4\u5e93\uff08\u8bbe\u5907\u6298\u6263\uff1a\u8212\u4eab 8 \u6298 \/ \u5c0a\u777f\u5168\u6548II 8.5 \u6298\uff0c\u5b89\u88c5\u8d39\u53ca\u914d\u4ef6\u4e0d\u6253\u6298\uff1b\u5355\u4ef7\u4ea7\u54c1\u4e0d\u6253\u6298\uff09\u3002\u6700\u7ec8\u4ef7\u683c\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u786e\u8ba4\u4e3a\u51c6\u3002<\/p>\n  <p style=\"margin-top:8px\" class=\"gold\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n<\/footer>\n\n<\/div>\n\n<script>\nfunction barStack(id, title, cats, series, colors){\n  var c = echarts.init(document.getElementById(id));\n  c.setOption({\n    title:{text:title,left:'center',textStyle:{fontSize:15,color:'#1a3a5c'}},\n    tooltip:{trigger:'axis',axisPointer:{type:'shadow'}},\n    legend:{bottom:0},\n    grid:{left:60,right:24,top:46,bottom:46},\n    xAxis:{type:'category',data:cats},\n    yAxis:{type:'value',name:'\u5143'},\n    series:series.map(function(s,i){return {name:s.name,type:'bar',stack:'t',data:s.data,itemStyle:{color:colors[i]},label:{show:true,formatter:function(p){return p.value>0?'\u00a5'+(p.value\/10000).toFixed(1)+'\u4e07':'';},color:'#333',fontSize:11}};})\n  });\n  window.addEventListener('resize',function(){c.resize();});\n}\n\/\/ S1 \u9762\u79ef\u51b7\u8d1f\u8377\uff08160W\/\u33a1\uff09\n(function(){\n  var c = echarts.init(document.getElementById('chartArea'));\n  c.setOption({\n    title:{text:'\u5404\u533a\u57df\u7a7a\u8c03\u51b7\u8d1f\u8377\uff08\u6309 160W\/\u33a1 \u8bbe\u8ba1\uff09',left:'center',textStyle:{fontSize:15,color:'#1a3a5c'}},\n    tooltip:{trigger:'axis',axisPointer:{type:'shadow'}},\n    legend:{bottom:0},\n    grid:{left:56,right:24,top:46,bottom:46},\n    xAxis:{type:'category',data:['\u5ba2\u5385','\u9910\u5385+\u53a8\u623f','\u6b21\u53671','\u6b21\u53672','\u6b21\u53673','\u4e3b\u5367+\u8863\u5e3d','\u4e66\u623f']},\n    yAxis:{type:'value',name:'kW'},\n    series:[\n      {name:'\u51b7\u8d1f\u8377(kW)',type:'bar',data:[5.7,2.7,2.4,1.5,2.7,3.5,1.6],itemStyle:{color:'#2980b9'},label:{show:true,position:'top',formatter:'{c}kW',fontSize:11}},\n      {name:'\u9762\u79ef(\u33a1)',type:'line',yAxisIndex:0,data:[35.7,17.0,15.0,9.6,17.0,22.0,10.0],itemStyle:{color:'#b8860b'}}\n    ]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n\/\/ S2 \u7ef4\u5ea6\u9886\u5148\uff08\u516d\u7ef4\u8bc4\u5206\uff09\n(function(){\n  var c = echarts.init(document.getElementById('chartDim'));\n  c.setOption({\n    title:{text:'\u65b9\u6848 A \/ B \u516d\u7ef4\u5ea6\u8bc4\u5206\u5bf9\u6bd4',left:'center',textStyle:{fontSize:15,color:'#1a3a5c'}},\n    tooltip:{trigger:'axis'},\n    legend:{bottom:0,data:['\u65b9\u6848A \u8212\u4eab','\u65b9\u6848B \u5c0a\u777f\u5168\u6548II']},\n    grid:{left:48,right:24,top:46,bottom:46},\n    xAxis:{type:'category',data:['\u521d\u6295\u8d44','\u8fd0\u884c\u8d39','\u8212\u9002\u5ea6','\u7a33\u5b9a\u6027','\u7ef4\u62a4\u8d39','\u5bff\u547d']},\n    yAxis:{type:'value',max:5,name:'\u2605'},\n    series:[\n      {name:'\u65b9\u6848A \u8212\u4eab',type:'bar',data:[5,3,3,4,4,4],itemStyle:{color:'#2980b9'}},\n      {name:'\u65b9\u6848B \u5c0a\u777f\u5168\u6548II',type:'bar',data:[3,4,5,4,3,4],itemStyle:{color:'#e74c3c'}}\n    ]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n\/\/ S3 \u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7\u6784\u6210\nbarStack('chartAC','\u7a7a\u8c03\u7cfb\u7edf\u62a5\u4ef7\u6784\u6210\u5bf9\u6bd4\uff08\u8bbe\u5907\u6298\u540e\/\u5b89\u88c5\uff09',\n  ['\u65b9\u6848A \u8212\u4eab','\u65b9\u6848B \u5c0a\u777f\u5168\u6548II'],\n  [{name:'\u8bbe\u5907\u6298\u540e',data:[43900,64117]},{name:'\u5b89\u88c5\u8d39',data:[14300,14200]}],\n  ['#2980b9','#e74c3c','#b8860b']);\n\/\/ S3 \u5730\u6696\u4e09\u65b9\u6848\u62a5\u4ef7\u6784\u6210\nbarStack('chartFloor','\u5730\u6696\u4e09\u65b9\u6848\u62a5\u4ef7\u6784\u6210\u5bf9\u6bd4\uff08\u9762\u79ef\u5957\u9910\/\u4e8c\u6b21\u7cfb\u7edf\/\u51b7\u51dd\u7089\u542b\u5b89\u88c5\uff09',\n  ['\u5730\u6696\u246099','\u5730\u6696\u2461119','\u5730\u6696\u2462169'],\n  [{name:'\u9762\u79ef\u5957\u9910',data:[18028,21670,30775]},{name:'\u4e8c\u6b21\u7cfb\u7edf',data:[3000,3000,3000]},{name:'\u51b7\u51dd\u7089+\u5b89\u88c5',data:[12315,12315,12315]}],\n  ['#27ae60','#e67e22','#1a3a5c']);\n\/\/ S5 \u516d\u7ef4\u96f7\u8fbe\n(function(){\n  var c = echarts.init(document.getElementById('chartRadar'));\n  c.setOption({\n    title:{text:'\u7a7a\u8c03\u53cc\u65b9\u6848 \u516d\u7ef4\u5ea6\u8bc4\u5206\u5bf9\u6bd4',left:'center',textStyle:{fontSize:15,color:'#1a3a5c'}},\n    tooltip:{},\n    legend:{bottom:0,data:['\u65b9\u6848A \u8212\u4eab','\u65b9\u6848B \u5c0a\u777f\u5168\u6548II']},\n    radar:{indicator:[\n      {name:'\u521d\u6295\u8d44',max:5},{name:'\u8fd0\u884c\u8d39',max:5},{name:'\u8212\u9002\u5ea6',max:5},\n      {name:'\u7a33\u5b9a\u6027',max:5},{name:'\u7ef4\u62a4\u8d39',max:5},{name:'\u5bff\u547d',max:5}],\n      radius:'62%',center:['50%','54%']},\n    series:[{type:'radar',data:[\n      {value:[5,3,3,4,4,4],name:'\u65b9\u6848A \u8212\u4eab',itemStyle:{color:'#2980b9'},areaStyle:{opacity:.15}},\n      {value:[3,4,5,4,3,4],name:'\u65b9\u6848B \u5c0a\u777f\u5168\u6548II',itemStyle:{color:'#e74c3c'},areaStyle:{opacity:.15}}\n    ]}]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n\/\/ S3 20\u5e74\u603b\u8d26\u5806\u53e0\n(function(){\n  var c = echarts.init(document.getElementById('chart20y'));\n  c.setOption({\n    title:{text:'20\u5e74\u603b\u8d26\u5bf9\u6bd4\uff08\u8212\u4eab+\u5730\u6696\u2461 vs \u5c0a\u777f+\u5730\u6696\u2461\uff09',left:'center',textStyle:{fontSize:15,color:'#1a3a5c'}},\n    tooltip:{trigger:'axis',axisPointer:{type:'shadow'}},\n    legend:{bottom:0},\n    grid:{left:64,right:24,top:46,bottom:46},\n    xAxis:{type:'category',data:['\u8212\u4eab+\u5730\u6696\u2461','\u5c0a\u777f+\u5730\u6696\u2461']},\n    yAxis:{type:'value',name:'\u5143'},\n    series:[\n      {name:'\u521d\u6295\u8d44',type:'bar',stack:'t',data:[58200+36985,78317+36985],itemStyle:{color:'#1a3a5c'},label:{show:true,formatter:function(p){return '\u00a5'+(p.value\/10000).toFixed(1)+'\u4e07';},color:'#fff',fontSize:11}},\n      {name:'20\u5e74\u8fd0\u884c\u8d39',type:'bar',stack:'t',data:[150000,140000],itemStyle:{color:'#2980b9'}},\n      {name:'20\u5e74\u7ef4\u62a4\u8d39',type:'bar',stack:'t',data:[8000,10000],itemStyle:{color:'#e67e22'}},\n      {name:'\u7b2c15\u5e74\u66f4\u6362',type:'bar',stack:'t',data:[63278,78268],itemStyle:{color:'#c0392b'},label:{show:true,position:'top',formatter:function(p){return '\u00a5'+(p.value\/10000).toFixed(1)+'\u4e07';},color:'#333',fontSize:11}}\n    ]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n\n\/\/ \u4e94\u6b65\u6cd5\u6b65\u9aa4\u5bfc\u822a \u00b7 \u6eda\u52a8\u9ad8\u4eae\u5f53\u524d\u6b65\u9aa4\n(function(){\n  var links = document.querySelectorAll('.stepbar a');\n  if(!links.length) return;\n  var map = {};\n  links.forEach(function(a){ map[a.getAttribute('data-target')] = a; });\n  var obs = new IntersectionObserver(function(entries){\n    entries.forEach(function(e){\n      if(e.isIntersecting){\n        links.forEach(function(a){ a.classList.remove('active'); });\n        var a = map[e.target.id];\n        if(a) a.classList.add('active');\n      }\n    });\n  }, {rootMargin:'-45% 0px -50% 0px', threshold:0});\n  ['s1','s2','s3','s4','s5'].forEach(function(id){\n    var el = document.getElementById(id);\n    if(el) obs.observe(el);\n  });\n})();\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u4e2d\u5fc3 \u00b7 \u522b\u5885\u51b7\u6696\u4e00\u4f53 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6814","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=6814\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u4e2d\u5fc3 \u00b7 \u522b\u5885\u51b7\u6696\u4e00\u4f53 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=6814\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-30T08:25:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"17 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814\",\"name\":\"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p02-05.jpeg\",\"datePublished\":\"2026-07-16T15:19:11+00:00\",\"dateModified\":\"2026-07-30T08:25:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p02-05.jpeg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p02-05.jpeg\",\"width\":427,\"height\":541},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6814#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=6814","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u4e2d\u5fc3 \u00b7 \u522b\u5885\u51b7\u6696\u4e00\u4f53 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=6814","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-30T08:25:13+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"17 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=6814","url":"https:\/\/longmai-nt.com\/?page_id=6814","name":"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=6814#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=6814#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg","datePublished":"2026-07-16T15:19:11+00:00","dateModified":"2026-07-30T08:25:13+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=6814#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=6814"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=6814#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-05.jpeg","width":427,"height":541},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=6814#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u5408\u9662 \u00b7 \u738b\u5148\u751f\u591a\u9879\u76ee\u5bf9\u6bd4\u65b9\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6814"}],"version-history":[{"count":12,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6814\/revisions"}],"predecessor-version":[{"id":9114,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6814\/revisions\/9114"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}