{"id":6940,"date":"2026-07-18T15:00:34","date_gmt":"2026-07-18T07:00:34","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=6940"},"modified":"2026-10-23T10:44:31","modified_gmt":"2026-10-23T02:44:31","slug":"%e6%bb%a8%e6%b9%96%e9%95%bf%e6%bb%a9%e8%8a%b1%e5%9b%adx%e8%80%81%e5%b8%88%e8%88%92%e4%ba%ab160%e6%8b%965%e5%8a%a0%e6%9a%97%e5%9f%8b%e6%9a%96%e6%b0%94%e7%89%87%e6%a1%a3%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=6940","title":{"rendered":"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848"},"content":{"rendered":"\n<style>\n\n\/* ===== \u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6863\u6848\u7f8e\u5316 V3.0 ===== *\/\n\/* \u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08 \u00b7 \u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94+\u6696\u6c14\u7247 *\/\n\n\/* --- \u5168\u5c40 --- *\/\n.entry-content { max-width: 860px; margin: 0 auto; padding: 20px 0; color: #2c3e50; line-height: 1.8; }\n.entry-content *, .entry-content *::before, .entry-content *::after { box-sizing: border-box; }\n\n\/* --- \u6807\u9898 --- *\/\nh1.wp-block-heading { color: #1a5276; font-size: 26px; text-align: center; border-bottom: 3px solid #c8960c; padding-bottom: 15px; margin-bottom: 10px; }\nh2.wp-block-heading { color: #1a5276; font-size: 20px; border-left: 4px solid #c8960c; padding-left: 12px; margin: 30px 0 15px; cursor: pointer; position: relative; padding-right: 40px; user-select: none; }\nh2.wp-block-heading::after { content: \"\u25bc\"; position: absolute; right: 0; top: 50%; transform: translateY(-50%); font-size: 16px; color: #e63946; transition: transform 0.3s; }\nh2.wp-block-heading.accordion-closed::after { content: \"\u25b6\"; transform: translateY(-50%); }\nh2.wp-block-heading.accordion-closed ~ * { display: none !important; }\nh2.wp-block-heading.accordion-closed ~ h2.wp-block-heading { display: block !important; }\nh3.wp-block-heading { color: #1a5276; font-size: 17px; border-left: 3px solid #c8960c; padding-left: 10px; margin: 20px 0 10px; }\n\n\/* --- \u526f\u6807\u9898 --- *\/\n.entry-content > p:first-of-type { text-align: center; font-size: 15px; color: #666; margin-top: 0; padding-bottom: 15px; border-bottom: 1px dashed #ddd; }\n\n\/* --- \u8868\u683c --- *\/\nfigure.wp-block-table { margin: 15px 0; border-collapse: collapse; font-size: 14px; }\nfigure.wp-block-table table { width: 100%; border-collapse: collapse; }\nfigure.wp-block-table th { background: #1a5276; color: #fff; padding: 10px 8px; text-align: center; font-weight: 600; border: 1px solid #154360; }\nfigure.wp-block-table td { padding: 8px; text-align: center; border: 1px solid #d5dbdb; }\nfigure.wp-block-table tbody tr:nth-child(even) { background: #f4f6f8; }\nfigure.wp-block-table tbody tr:hover { background: #d5f5e3; }\n\n\/* --- \u76ee\u5f55 --- *\/\n.entry-content ol:first-of-type { background: #e8f0fe; border-radius: 8px; padding: 20px 20px 20px 40px; columns: 2; column-gap: 30px; margin: 20px 0; list-style: none; counter-reset: toc-counter; }\n.entry-content ol:first-of-type li { counter-increment: toc-counter; margin: 6px 0; font-size: 14px; }\n.entry-content ol:first-of-type li::before { content: counter(toc-counter) \". \"; color: #1a5276; font-weight: 700; }\n.entry-content ol:first-of-type a { color: #1a5276; text-decoration: none; border-bottom: 1px dotted #c8960c; }\n.entry-content ol:first-of-type a:hover { color: #c8960c; }\n\n\/* --- \u5206\u9694\u7ebf --- *\/\n.wp-block-separator { margin: 30px auto; border: none; height: 1px; background: linear-gradient(to right, transparent, #c8960c, transparent); }\n\n\/* --- \u6807\u7b7e --- *\/\n.tag-badge { display: inline-block; background: #1a5276; color: #fff; padding: 3px 10px; border-radius: 4px; font-size: 12px; margin: 2px; }\n\n\/* --- \u4fe1\u606f\u5361 --- *\/\n.geo-card { background: #f4f6f8; border: 1px solid #d5dbdb; border-radius: 8px; padding: 20px; margin: 20px 0; }\n.geo-card .geo-field { margin: 8px 0; font-size: 14px; }\n.geo-card .geo-label { font-weight: 700; color: #1a5276; display: inline-block; min-width: 100px; }\n\n\/* --- \u7167\u7247\u63d0\u793a\u6846 --- *\/\n.photo-tip { border: 2px dashed #2980b9; background: #eaf2f8; border-radius: 8px; padding: 20px; margin: 15px 0; text-align: center; color: #2980b9; font-size: 14px; }\n\n\/* --- \u4f18\u52bf\u5361\u7247 --- *\/\n.advantage-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 12px; margin: 15px 0; }\n.advantage-card { background: #f4f6f8; border-radius: 8px; padding: 15px; border-left: 4px solid #c8960c; }\n.advantage-card h4 { margin: 0 0 8px; color: #1a5276; font-size: 15px; }\n.advantage-card p { margin: 0; font-size: 13px; color: #555; }\n\n\/* --- \u5f15\u7528\/\u63d0\u793a\u6846 --- *\/\n.callout { background: #fef9e7; border-left: 4px solid #c8960c; padding: 15px; margin: 15px 0; border-radius: 4px; font-size: 14px; }\n.callout-blue { background: #eaf2f8; border-left: 4px solid #2980b9; padding: 15px; margin: 15px 0; border-radius: 4px; font-size: 14px; }\n\n\/* --- \u5185\u94fe\u5361\u7247 --- *\/\n.link-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 10px; margin: 15px 0; }\n.link-card { background: #f4f6f8; border-radius: 6px; padding: 12px; border: 1px solid #d5dbdb; }\n.link-card a { color: #1a5276; text-decoration: none; font-weight: 600; font-size: 14px; display: block; }\n.link-card a:hover { color: #c8960c; }\n.link-card p { margin: 4px 0 0; font-size: 12px; color: #777; }\n\n\/* --- CTA --- *\/\n.cta-box { background: linear-gradient(135deg, #1a5276, #2980b9); color: #fff; border-radius: 8px; padding: 25px; text-align: center; margin: 20px 0; }\n.cta-box h3 { color: #fff; margin: 0 0 10px; font-size: 18px; border: none; padding: 0; }\n.cta-box p { margin: 5px 0; font-size: 14px; color: #d5f5e3; }\n.cta-box a { color: #c8960c; text-decoration: none; font-weight: 700; font-size: 16px; }\n.cta-box a:hover { color: #f7dc6f; }\n\n\/* --- \u6807\u7b7e\u884c --- *\/\n.tag-line { text-align: center; margin: 10px 0; }\n\n\/* --- \u8131\u654f\u58f0\u660e --- *\/\n.disclaimer { background: #f9ebeb; border: 1px solid #e6b0aa; border-radius: 4px; padding: 10px 15px; font-size: 12px; color: #922b21; margin: 20px 0; }\n\n\/* --- Footer --- *\/\n.entry-footer { text-align: center; font-size: 12px; color: #999; padding: 20px 0; border-top: 1px solid #eee; margin-top: 30px; }\n\n\n\n\/* --- \u65bd\u5de5\u7167\u7247\u7f51\u683c\uff08\u6ee8\u6e56\u957f\u6ee9\u4e13\u5c5e\uff09 --- *\/\n.bhct-case .photo-grid {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 10px;\n  margin: 12px 0;\n}\n\n.bhct-case .photo-grid .photo-item { text-align: center; }\n.bhct-case .photo-grid .photo-item .img-wrap {\n  position: relative; width: 100%; aspect-ratio: 1 \/ 1;\n  overflow: hidden; border-radius: 8px; cursor: pointer;\n  background: #f0f0f0;\n}\n.bhct-case .photo-grid .photo-item .img-wrap img {\n  width: 100%; height: 100%; object-fit: cover;\n  transition: transform 0.3s; display: block;\n}\n.bhct-case .photo-grid .photo-item .img-wrap:hover img {\n  transform: scale(1.05);\n}\n.bhct-case .photo-grid .photo-item .caption {\n  font-size: 11px; color: #555; margin-top: 4px; line-height: 1.3;\n  display: -webkit-box; -webkit-line-clamp: 2; -webkit-box-orient: vertical;\n  overflow: hidden; min-height: 28px;\n}\n\n\/* --- \u54cd\u5e94\u5f0f --- *\/\n@media (max-width: 768px) {\n@media (max-width: 768px) {\n  .bhct-case .photo-grid { grid-template-columns: repeat(2, 1fr) !important; }\n}\n  .entry-content ol:first-of-type { columns: 1; }\n  .advantage-grid, .link-grid { grid-template-columns: 1fr; }\n  figure.wp-block-table { font-size: 12px; }\n  figure.wp-block-table th, figure.wp-block-table td { padding: 6px 4px; }\n  h1.wp-block-heading { font-size: 22px; }\n}\n\n\n\n\/* --- \u65bd\u5de5\u7167\u7247\u7f51\u683c\uff08\u6ee8\u6e56\u957f\u6ee9\u4e13\u5c5e\uff09 --- *\/\n.bhct-case .photo-grid {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 10px;\n  margin: 12px 0;\n}\n\n.bhct-case .photo-grid .photo-item { text-align: center; }\n.bhct-case .photo-grid .photo-item .img-wrap {\n  position: relative; width: 100%; aspect-ratio: 1 \/ 1;\n  overflow: hidden; border-radius: 8px; cursor: pointer;\n  background: #f0f0f0;\n}\n.bhct-case .photo-grid .photo-item .img-wrap img {\n  width: 100%; height: 100%; object-fit: cover;\n  transition: transform 0.3s; display: block;\n}\n.bhct-case .photo-grid .photo-item .img-wrap:hover img {\n  transform: scale(1.05);\n}\n.bhct-case .photo-grid .photo-item .caption {\n  font-size: 11px; color: #555; margin-top: 4px; line-height: 1.3;\n  display: -webkit-box; -webkit-line-clamp: 2; -webkit-box-orient: vertical;\n  overflow: hidden; min-height: 28px;\n}\n\n\n.bhct-case .photo-grid.cols-4 { grid-template-columns: repeat(4, 1fr); }\n.bhct-case .photo-grid.cols-2 { grid-template-columns: repeat(2, 1fr); }\n\n\/* --- \u6863\u6848\u4e13\u7528\u6837\u5f0f --- *\/\n.bhct-case .archive-table { margin: 15px 0; font-size: 14px; width: 100%; border-collapse: collapse; }\n.bhct-case .archive-table th { background: #1a5276; color: #fff; padding: 8px; text-align: center; font-weight: 600; border: 1px solid #154360; }\n.bhct-case .archive-table td { padding: 8px; border: 1px solid #d5dbdb; }\n.bhct-case .archive-table tr:nth-child(even) { background: #f4f6f8; }\n.bhct-case .archive-table .empty-cell { color: #bbb; font-style: italic; }\n\n.bhct-case .step-card {\n  background: #f4f6f8; border-left: 4px solid #c8960c;\n  border-radius: 6px; padding: 15px; margin: 15px 0;\n}\n.bhct-case .step-card h4 { margin: 0 0 8px; color: #1a5276; font-size: 15px; }\n.bhct-case .step-card p { margin: 0; font-size: 13px; color: #555; }\n.bhct-case .step-num {\n  display: inline-block; background: #1a5276; color: #fff;\n  width: 28px; height: 28px; border-radius: 50%; text-align: center;\n  line-height: 28px; font-size: 14px; font-weight: 700; margin-right: 8px;\n}\n\n<\/style>\n\n\n\n<div class=\"bhct-case\">\n\n\n\n<h1 class=\"wp-block-heading\" id=\"top\">\u6210\u90fd\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed\uff5c\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94+\u6696\u6c14\u7247\u00b7\u9879\u76ee\u6863\u6848\u4e66<\/h1>\n\n\n<p class=\"wp-block-paragraph\" style=\"text-align:center;font-size:14px;color:#666;\">\u5173\u6ce8\u7528\u623720\u5e74\u4f7f\u7528\u8212\u9002\u3001\u7a33\u5b9a\u3001\u8282\u80fd\u2014\u2014\u6863\u6848\u4e3a\u7528\u6237\u63d0\u4f9b\u670d\u52a1\u4fdd\u969c\u53ef\u89c6\u5316<\/p>\n\n\n<p class=\"wp-block-paragraph\">\u6210\u90fd\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\uff0c\u4ec51\u4e2a\u5916\u673a\u4f4d\uff0c\u9009\u62e9\u65e5\u7acb\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94\u7a7a\u8c03\u65b9\u6848\uff0c127%\u8d85\u914d\u7387\u8bbe\u8ba1\u3002\u642d\u914d5\u7ec4\u6696\u6c14\u7247\u91c7\u6696\u7cfb\u7edf\uff0c\u5ba2\u6237\u81ea\u5907\u9505\u7089\uff0c\u9f99\u8109\u6696\u901a\u8d1f\u8d23\u5168\u6848\u7ba1\u8def\u8bbe\u8ba1\u5b89\u88c5\u3002<\/p>\n\n\n<hr class=\"wp-block-separator\"\/>\n\n<p class=\"tag-line\">\n<span class=\"tag-badge\">#\u6210\u90fd\u6696\u901a<\/span>\n<span class=\"tag-badge\">#\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed<\/span>\n<span class=\"tag-badge\">#\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247<\/span>\n<span class=\"tag-badge\">#\u4e2d\u592e\u7a7a\u8c03+\u6696\u6c14\u7247<\/span>\n<span class=\"tag-badge\">#\u6696\u6c14\u7247\u7ba1\u8def\u8bbe\u8ba1<\/span>\n<span class=\"tag-badge\">#\u65b9\u6848\u9884\u6848\u4f8b<\/span>\n<\/p>\n\n<hr class=\"wp-block-separator\"\/>\n\n\n<h2 class=\"wp-block-heading\" id=\"toc\">\ud83d\udcd1 \u76ee\u5f55<\/h2>\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"#m1\">\u9879\u76ee\u4fe1\u606f<\/a><\/li>\n<li><a href=\"#m2\">\u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/a><\/li>\n<li><a href=\"#m3\">\u6750\u6599\u6e05\u5355<\/a><\/li>\n<li><a href=\"#m4\">\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/a><\/li>\n<li><a href=\"#m5\">\u5ba2\u6237\u53cd\u9988<\/a><\/li>\n<li><a href=\"#m6\">\u80fd\u8017\u8ddf\u8e2a\u6863\u6848<\/a><\/li>\n<li><a href=\"#m7\">\u5ba2\u6237\u670d\u52a1\u8bb0\u5f55<\/a><\/li>\n<li><a href=\"#m8\">\u9644\u4ef6\u6e05\u5355<\/a><\/li>\n<li><a href=\"#m9\">\u65b9\u6848\u524d\u4e66<\/a><\/li>\n<li><a href=\"#m10\">\u540c\u6237\u578b\u5bf9\u6807<\/a><\/li>\n<li><a href=\"#m11\">\u5185\u94fe\u5173\u8054<\/a><\/li>\n<li><a href=\"#m12\">\u8054\u7cfb\u65b9\u5f0f<\/a><\/li>\n<\/ol>\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n<h2 class=\"wp-block-heading\" id=\"m1\">\u4e00\u3001\u9879\u76ee\u4fe1\u606f<\/h2>\n\n\n<h3 class=\"wp-block-heading\">1.1 \u9879\u76ee\u6982\u51b5<\/h3>\n\n\n<table class=\"archive-table\"><tbody>\n<tr><td><strong>\u5ba2\u6237<\/strong><\/td><td>X\u8001\u5e08<\/td><\/tr>\n<tr><td><strong>\u697c\u76d8<\/strong><\/td><td>\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed<\/td><\/tr>\n<tr><td><strong>\u6237\u578b<\/strong><\/td><td>\u4e09\u5ba4\u4e24\u5385<\/td><\/tr>\n<tr><td><strong>\u7a7a\u8c03\u9762\u79ef<\/strong><\/td><td>\u7ea691.5\u33a1<\/td><\/tr>\n<tr><td><strong>\u7cfb\u7edf\u5f62\u5f0f<\/strong><\/td><td>\u6c1f\u7cfb\u7edf\u591a\u8054\u673a + \u6696\u6c14\u7247\u6c34\u7cfb\u7edf<\/td><\/tr>\n<tr><td><strong>\u5916\u673a<\/strong><\/td><td>\u65e5\u7acb\u8212\u4eabSET-FREE RAS-160HRNBQ \u53cc\u98ce\u6247\uff0815.5kW\/18.0kW\uff09<\/td><\/tr>\n<tr><td><strong>\u5185\u673a\u914d\u7f6e<\/strong><\/td><td>71\u578b+32\u578b\uff08\u5ba2\u5385\uff09+ 40\u578b\uff08\u4e3b\u5367\uff09+ 32\u578b\uff08\u6b21\u5367\uff09+ 22\u578b\uff08\u6b21\u5367\uff09<\/td><\/tr>\n<tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>127%<\/td><\/tr>\n<tr><td><strong>\u91c7\u6696\u65b9\u5f0f<\/strong><\/td><td>\u6696\u6c14\u72475\u7ec4\uff08\u5ba2\u6237\u81ea\u5907\u9505\u7089\uff09<\/td><\/tr>\n<tr><td><strong>\u65bd\u5de5\u65b9<\/strong><\/td><td>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6210\u90fd\u6388\u6743\u7ecf\u9500\u5546\uff082025\u94bb\u77f3\u5b89\u88c5\u5546\uff09<\/td><\/tr>\n<tr><td><strong>\u65bd\u5de5\u6807\u51c6<\/strong><\/td><td>\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/td><\/tr>\n<tr><td><strong>\u6587\u6863\u7f16\u53f7<\/strong><\/td><td>BHCT-X-2026-001<\/td><\/tr>\n<\/tbody><\/table>\n\n\n<h3 class=\"wp-block-heading\">1.2 \u4e1a\u4e3b\u80cc\u666f\u4e0e\u7279\u6b8a\u9700\u6c42<\/h3>\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5916\u673a\u4f4d\u9650\u5236<\/strong>\uff1a\u4ec5\u4e00\u4e2a\u5916\u673a\u4f4d\uff0c\u5fc5\u987b\u9009\u62e9<strong>\u591a\u8054\u673a\u65b9\u6848<\/strong><\/li>\n<li><strong>\u5c42\u9ad8\u8981\u6c42<\/strong>\uff1a\u4ecb\u610f\u5c42\u9ad8\uff0c\u6307\u5b9a\u505a<strong>\u6696\u6c14\u7247<\/strong>\uff0c\u4e0d\u505a\u5730\u6696<\/li>\n<li><strong>\u7279\u6b8a\u8eab\u4efd<\/strong>\uff1a\u5ba2\u6237\u4ece\u4e8b\u9505\u7089\u76f8\u5173\u4e1a\u52a1\uff0c\u81ea\u884c\u63d0\u4f9b\u9505\u7089\uff0c\u5bf9\u91c7\u6696\u7cfb\u7edf\u6709\u6df1\u5165\u4e86\u89e3<\/li>\n<li><strong>\u6838\u5fc3\u9700\u6c42<\/strong>\uff1a\u4e2d\u592e\u7a7a\u8c03\u5236\u51b7\u5236\u70ed + \u6696\u6c14\u7247\u91c7\u6696<\/li>\n<\/ul>\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n<h2 class=\"wp-block-heading\" id=\"m2\">\u4e8c\u3001\u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/h2>\n\n\n<h3 class=\"wp-block-heading\">2.1 \u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/h3>\n\n\n<div class=\"step-card\">\n<h4>\ud83d\udccb \u52d8\u6d4b\u5185\u5bb9<\/h4>\n<p>\u6237\u578b\u9762\u79ef\u786e\u8ba4 \/ \u5916\u673a\u4f4d\u6761\u4ef6 \/ \u7535\u6e90\u6761\u4ef6 \/ \u5c42\u9ad8\u786e\u8ba4 \/ \u5404\u623f\u95f4\u529f\u80fd\u786e\u8ba4 \/ \u6696\u6c14\u7247\u5b89\u88c5\u4f4d\u7f6e\u786e\u8ba4 \/ \u5ba2\u6237\u9505\u7089\u5bf9\u63a5\u9700\u6c42\u786e\u8ba4<\/p>\n<\/div>\n\n<div class=\"photo-tip\">\ud83d\udcf8 \u73b0\u573a\u52d8\u6d4b\u7167\u7247\uff08\u5f85\u8865\u5145\uff09<\/div>\n\n<h3 class=\"wp-block-heading\">2.2 \u7b2c\u4e8c\u6b65\uff1a\u7cfb\u7edf\u8bbe\u8ba1<\/h3>\n\n\n<div class=\"step-card\">\n<h4>\ud83d\udcd0 \u8bbe\u8ba1\u5185\u5bb9<\/h4>\n<p>\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97\uff08GB 50736-2012\uff09\/ \u7a7a\u8c03\u5185\u673a\u9009\u578b\u4e0e\u5b9a\u4f4d \/ \u6696\u6c14\u7247\u6563\u70ed\u5668\u9009\u578b \/ \u7ba1\u8def\u8d70\u5411\u8bbe\u8ba1 \/ \u8d85\u914d\u7387\u6838\u7b97<\/p>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\" style=\"font-size:14px;color:#1a5276;margin:10px 0 5px;\">\u8bbe\u8ba1\u56fe\u7eb8<\/h4>\n\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan.png')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan.png\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6696\u6c14\u56fe\u7eb8png\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6696\u6c14\u56fe\u7eb8png<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-plan.png')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-plan.png\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u56fe\u7eb8png\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u56fe\u7eb8png<\/div><\/div>\n<\/div>\n<!-- \/wp:post-content -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">2.3 \u7b2c\u4e09\u6b65\uff1a\u6750\u6599\u8fdb\u573a<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"step-card\">\n<h4>\ud83d\udce6 \u6750\u6599\u9a8c\u6536\u5185\u5bb9<\/h4>\n<p>\u4e3b\u673a\/\u5185\u673a\/\u6696\u6c14\u7247\/\u7ba1\u6750\/\u8f85\u6750\u7684\u54c1\u724c\u3001\u578b\u53f7\u3001\u6570\u91cf\u6838\u5bf9<\/p>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:html --><div class=\"photo-tip\">\ud83d\udcf8 \u6750\u6599\u8fdb\u573a\u5168\u666f\u7167\u7247+\u54c1\u724c\u6807\u7b7e\u7279\u5199\uff08\u5f85\u8865\u5145\uff09<\/div><!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">2.4 \u7b2c\u56db\u6b65\uff1a\u7cfb\u7edf\u5b89\u88c5<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:heading {\"level\":4} -->\n<h4 class=\"wp-block-heading\" style=\"font-size:14px;color:#1a5276;margin:10px 0 5px;\">\u7a7a\u8c03\u65bd\u5de5\u6807\u51c6<\/h4>\n<!-- \/wp:heading -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u6807\u51c6<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u5de5\u5e8f<\/th><th>\u5185\u5bb9<\/th><th>\u6807\u51c6<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u2460 \u56fe\u7eb8\u5b9a\u4f4d<\/td><td>\u4e13\u5c5e\u65bd\u5de5\u56fe\u7eb8+\u73b0\u573a\u5b9a\u4f4d\u4ea4\u5e95<\/td><td>\u7cbe\u786e\u5230cm<\/td><\/tr>\n<tr><td>\u2461 \u6750\u6599\u9a8c\u6536<\/td><td>\u8bbe\u5907\u6750\u6599\u6309\u6e05\u5355\u9a8c\u6536+\u58c1\u539a\u5b9e\u62cd<\/td><td>\u900f\u660e\u53ef\u67e5<\/td><\/tr>\n<tr><td>\u2462 \u6309\u56fe\u65bd\u5de5<\/td><td>\u5bf9\u7167\u56fe\u7eb8\u65bd\u5de5+\u7279\u6b8a\u914d\u7f6e\u5b89\u88c5\u7279\u5199<\/td><td>\u7559\u6863\u53ef\u67e5<\/td><\/tr>\n<tr><td>\u2463 \u94dc\u7ba1\u710a\u63a5<\/td><td>\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/td><td>\u9632\u6b62\u6c27\u5316<\/td><\/tr>\n<tr><td>\u2464 \u9690\u853d\u9a8c\u6536<\/td><td>\u7528\u6237\/\u76d1\u7406\/\u9879\u76ee\u7ecf\u7406\u4e09\u65b9\u9a8c\u6536\u7b7e\u5b57<\/td><td>\u4e09\u65b9\u786e\u8ba4<\/td><\/tr>\n<tr><td>\u2465 \u8c03\u8bd5\u4ea4\u4ed8<\/td><td>\u62bd\u771f\u7a7a\u22652h+\u4fdd\u538b24h+\u51b7\u5a92\u7cbe\u786e\u8ffd\u52a0<\/td><td>\u7cfb\u7edf\u6700\u4f18<\/td><\/tr>\n<tr><td>\u2466 \u4f7f\u7528\u6559\u5b66<\/td><td>\u5de5\u7a0b\u5e08\u4e00\u5bf9\u4e00\u6559\u4f1a\u4f7f\u7528+\u4f7f\u7528\u6307\u5357<\/td><td>\u653e\u5fc3\u4f7f\u7528<\/td><\/tr>\n<tr><td>\u2467 \u6863\u6848\u5efa\u7acb<\/td><td>\u5efa\u7acb\u9879\u76ee\u6863\u6848\u4e66+\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212<\/td><td>10\u5e74\u8ddf\u8e2a<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n<!-- wp:heading {\"level\":4} -->\n<h4 class=\"wp-block-heading\" style=\"font-size:14px;color:#1a5276;margin:10px 0 5px;\">\u6696\u6c14\u7247\u5b89\u88c5\u6807\u51c6<\/h4>\n<!-- \/wp:heading -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u5de5\u5e8f<\/th><th>\u6807\u51c6\u8981\u6c42<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5e03\u7ba1\u65b9\u5f0f<\/td><td>\u6697\u88c5\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\uff0c\u4fdd\u8bc1\u6c34\u529b\u5e73\u8861<\/td><\/tr>\n<tr><td>\u7ba1\u5f84\u8981\u6c42<\/td><td>\u4e3b\u7ba1\u2265De32\uff0c\u652f\u7ba1\u2265De20<\/td><\/tr>\n<tr><td>\u6253\u538b\u6d4b\u8bd5<\/td><td>0.6MPa \u7a33\u538b\u22651\u5c0f\u65f6\uff0c\u538b\u964d\u22640.05MPa<\/td><\/tr>\n<tr><td>\u7ba1\u6750\u9009\u62e9<\/td><td>\u94dd\u5851\u590d\u5408\u7ba1\u6216\u5e26EVOH\u963b\u6c27\u5c42\u7ba1\u6750<\/td><\/tr>\n<tr><td>\u5b89\u88c5\u4f4d\u7f6e<\/td><td>\u7a97\u4e0b\u6700\u4f73\uff0c\u5f62\u6210\u70ed\u5e55\u5e18\u963b\u9694\u51b7\u7a7a\u6c14<\/td><\/tr>\n<tr><td>\u8054\u52a8\u63a7\u5236<\/td><td>\u52a0\u88c5\u65e0\u7ebf\u8054\u52a8\u63a7\u5236\u5668<\/td><\/tr>\n<tr><td>\u6c34\u529b\u5e73\u8861\u9a8c\u8bc1<\/td><td>\u5404\u623f\u95f4\u6e29\u5dee\u2264\u00b11\u2103<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n<!-- wp:heading {\"level\":4} -->\n<h4 class=\"wp-block-heading\" style=\"font-size:14px;color:#1a5276;margin:10px 0 5px;\">\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b\u65bd\u5de5\u5b9e\u62cd<\/h4>\n<!-- \/wp:heading -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-00.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-00.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-01.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-01.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b01\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b01<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-05.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-05.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b05\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b05<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-4\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-08.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-08.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b08\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b08<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-09.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-09.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b09\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b09<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-11.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-11.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b11\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b11<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-18.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-18.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b18\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b18<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-02.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-02.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b02\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b02<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-03.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-03.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b03\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b03<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-04.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-04.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b04\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b04<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-06.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-06.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b06\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b06<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-07.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-07.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b07\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b07<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-10.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-10.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b10\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b10<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-12.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-12.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b12\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b12<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-13.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-13.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b13\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b13<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-14.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-14.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b14\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b14<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-15.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-15.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b15\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b15<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-16.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-16.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b16\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b16<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-17.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-17.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b17\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b17<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-19.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-19.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b19\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b19<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-20.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-20.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b20\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b20<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-21.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-concealed-heating-21.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b21\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u6697\u57cb\u6696\u6c14\u7247\u9690\u853d\u5de5\u7a0b21<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":4} -->\n<h4 class=\"wp-block-heading\" style=\"font-size:14px;color:#1a5276;margin:10px 0 5px;\">\u7a7a\u8c03\u5b89\u88c5\u5b9e\u62cd<\/h4>\n<!-- \/wp:heading -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-livingroom-indoor.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-livingroom-indoor.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u5ba2\u5385\u5185\u673a\u5b89\u88c5\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u5ba2\u5385\u5185\u673a\u5b89\u88c5<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-unit-03.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-unit-03.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c503\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c503<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-unit-04.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-unit-04.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c504\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c504<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-pipe-00.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-pipe-00.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u8d70\u7ba1\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u8d70\u7ba1<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-pipe-01.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-pipe-01.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u8d70\u7ba101\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u8d70\u7ba101<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-pipe-02.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-indoor-pipe-02.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u8d70\u7ba102\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u8d70\u7ba102<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-outdoor-damper.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-outdoor-damper.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u51cf\u9707\u57ab\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u51cf\u9707\u57ab<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-study-indoor.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-study-indoor.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u4e66\u623f\u4e0b\u51fa\u98ce\u5185\u673a\u5b89\u88c5\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u4e66\u623f\u4e0b\u51fa\u98ce\u5185\u673a\u5b89\u88c5<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-outdoor-unit-01.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-outdoor-unit-01.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u5b89\u88c501\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u5b89\u88c501<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<div class=\"photo-grid cols-3\">\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-double-damper-nut.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-double-damper-nut.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5b89\u88c5\u53cc\u51cf\u9707\u53cc\u87ba\u6bcd\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u5b89\u88c5\u53cc\u51cf\u9707\u53cc\u87ba\u6bcd<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-wire-controller-01.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-wire-controller-01.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u7ebf\u63a7\u5668\u5e03\u7ebf01\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u7ebf\u63a7\u5668\u5e03\u7ebf01<\/div><\/div>\n<div class=\"photo-item\"><div class=\"img-wrap\" onclick=\"openLightbox('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-wire-controller-02.jpg')\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-ac-wire-controller-02.jpg\" alt=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u7ebf\u63a7\u5668\u5e03\u7ebf02\" loading=\"lazy\"><\/div><div class=\"caption\">\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u7a7a\u8c03\u7ebf\u63a7\u5668\u5e03\u7ebf02<\/div><\/div>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">2.5 \u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"step-card\">\n<h4>\ud83d\udd27 \u8c03\u8bd5\u5185\u5bb9<\/h4>\n<p><strong>\u7a7a\u8c03\u7cfb\u7edf<\/strong>\uff1a\u62bd\u771f\u7a7a\u22652h \/ \u4fdd\u538b24h \/ \u51b7\u5a92\u7cbe\u786e\u8ffd\u52a0 \/ \u6bcf\u53f0\u5185\u673a\u5236\u51b7\u5236\u70ed\u6d4b\u8bd5 \/ \u7ebf\u63a7\u5668+WiFi\u8fdc\u7a0b\u63a7\u5236\u8c03\u8bd5<\/p>\n<p><strong>\u6696\u6c14\u7247\u7cfb\u7edf<\/strong>\uff1a\u7ba1\u8def\u6253\u538b0.6MPa\u7a33\u538b\u22651h \/ \u5404\u6696\u6c14\u7247\u6392\u6c14\u6563\u70ed\u6d4b\u8bd5 \/ \u6c34\u529b\u5e73\u8861\u8c03\u8282 \/ \u8054\u52a8\u63a7\u5236\u8c03\u8bd5 \/ \u9505\u7089\u63a5\u53e3\u5bf9\u63a5<\/p>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:html --><div class=\"photo-tip\">\ud83d\udcf8 \u8c03\u8bd5\u8fc7\u7a0b\u7167\u7247\uff08\u5f85\u8865\u5145\uff09<\/div><!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">2.6 \u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"step-card\">\n<h4>\u2705 \u9a8c\u6536\u5185\u5bb9<\/h4>\n<p>\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c \/ \u5404\u623f\u95f4\u5236\u51b7\/\u5236\u70ed\u6548\u679c\u786e\u8ba4 \/ \u6696\u6c14\u7247\u6563\u70ed\u6548\u679c\u786e\u8ba4 \/ \u9505\u7089\u8054\u52a8\u6d4b\u8bd5<\/p>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:html --><div class=\"photo-tip\">\ud83d\udcf8 \u7ae3\u5de5\u9a8c\u6536\u73b0\u573a\u7167\u7247\uff08\u5f85\u8865\u5145\uff09<\/div><!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">2.7 +1\uff1a\u4ea4\u4ed8\u6559\u5b66<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"step-card\">\n<h4>\ud83c\udf93 \u6559\u5b66\u5185\u5bb9<\/h4>\n<p>\u2460\u7a7a\u8c03\u5f00\u5173\u673a\u53ca\u6e29\u5ea6\u8bbe\u5b9a \/ \u2461\u6696\u6c14\u7247\u6e29\u63a7\u9600\u64cd\u4f5c \/ \u2462\u9505\u7089\u4e0e\u8054\u52a8\u63a7\u5236\u5668\u4f7f\u7528 \/ \u2463APP\u8fdc\u7a0b\u63a7\u5236 \/ \u2464\u6ee4\u7f51\u6e05\u6d17\u5468\u671f\u63d0\u9192<\/p>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:html --><div class=\"photo-tip\">\ud83d\udcf8 \u4ea4\u4ed8\u6559\u5b66\u73b0\u573a\u7167\u7247\uff08\u5f85\u8865\u5145\uff09<\/div><!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">2.8 +2\uff1a\u552e\u540e\u4fdd\u969c<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><tbody>\n<tr><td><strong>\u8bbe\u5907\u8d28\u4fdd<\/strong><\/td><td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd<\/td><\/tr>\n<tr><td><strong>\u5de5\u7a0b\u8d28\u4fdd<\/strong><\/td><td>5\u5e74\u8d77<\/td><\/tr>\n<tr><td><strong>\u4e09\u65b9\u8054\u4fdd<\/strong><\/td><td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td><\/tr>\n<tr><td><strong>\u4f1a\u5458\u670d\u52a1<\/strong><\/td><td>\u5e74\u5ea6\u68c0\u6d4b\/\u7ef4\u4fdd\u63d0\u9192\/\u4f18\u5148\u54cd\u5e94\/\u670d\u52a1\u6298\u6263\/\u8fdc\u7a0b\u8bca\u65ad<\/td><\/tr>\n<tr><td><strong>\u7d27\u6025\u62a5\u4fee<\/strong><\/td><td>\u65e5\u7acb\u5b98\u65b9400\u7535\u8bdd \/ \u9f99\u8109\u6696\u901a\u552e\u540e\u7535\u8bdd<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m3\">\u4e09\u3001\u6750\u6599\u6e05\u5355<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u7a7a\u8c03\u7cfb\u7edf\u6750\u6599<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><thead><tr><th>\u7c7b\u522b<\/th><th>\u9879\u76ee<\/th><th>\u54c1\u724c\/\u7cfb\u5217<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead><tbody>\n<tr><td>\u4e3b\u673a<\/td><td>\u5916\u673a<\/td><td>\u65e5\u7acb\u8212\u4eabSET-FREE<\/td><td>RAS-160HRNBQ<\/td><td>1\u53f0<\/td><\/tr>\n<tr><td>\u5185\u673a<\/td><td>\u5ba2\u5385\u4e3b\u5185\u673a<\/td><td>\u65e5\u7acb\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr>\n<tr><td>\u5185\u673a<\/td><td>\u5ba2\u5385\u8f85\u5185\u673a<\/td><td>\u65e5\u7acb\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr>\n<tr><td>\u5185\u673a<\/td><td>\u4e3b\u5367\u5185\u673a<\/td><td>\u65e5\u7acb\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr>\n<tr><td>\u5185\u673a<\/td><td>\u6b21\u53671\u5185\u673a<\/td><td>\u65e5\u7acb\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr>\n<tr><td>\u5185\u673a<\/td><td>\u6b21\u53672\u5185\u673a<\/td><td>\u65e5\u7acb\u8584\u578b\u98ce\u7ba1\u5f0f<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1\u53f0<\/td><\/tr>\n<tr><td>\u8f85\u6750<\/td><td>\u94dc\u7ba1\/\u4fdd\u6e29\/\u5206\u6b67\u7ba1\u7b49<\/td><td>\u2014<\/td><td>\u6309\u7cbe\u5de5\u6807\u51c6\u914d\u7f6e<\/td><td>1\u5957<\/td><\/tr>\n<tr><td>\u63a7\u5236<\/td><td>\u7ebf\u63a7\u5668<\/td><td>\u65e5\u7acb<\/td><td>PC-P1HVQA<\/td><td>5\u53f0<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u6696\u6c14\u7247\u7cfb\u7edf\u6750\u6599<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><thead><tr><th>\u7c7b\u522b<\/th><th>\u9879\u76ee<\/th><th>\u54c1\u724c\/\u7cfb\u5217<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead><tbody>\n<tr><td>\u6563\u70ed\u672b\u7aef<\/td><td>\u5ba2\u5385\u6696\u6c14\u7247<\/td><td>\u94a2\u5236\u677f\u5f0f<\/td><td>600\u00d72000<\/td><td>2\u7ec4<\/td><\/tr>\n<tr><td>\u6563\u70ed\u672b\u7aef<\/td><td>\u4e3b\u5367\u6696\u6c14\u7247<\/td><td>\u94a2\u5236\u677f\u5f0f<\/td><td>600\u00d71600<\/td><td>1\u7ec4<\/td><\/tr>\n<tr><td>\u6563\u70ed\u672b\u7aef<\/td><td>\u6b21\u53671\u6696\u6c14\u7247<\/td><td>\u94a2\u5236\u677f\u5f0f<\/td><td>600\u00d71200<\/td><td>1\u7ec4<\/td><\/tr>\n<tr><td>\u6563\u70ed\u672b\u7aef<\/td><td>\u6b21\u53672\u6696\u6c14\u7247<\/td><td>\u94a2\u5236\u677f\u5f0f<\/td><td>600\u00d71000<\/td><td>1\u7ec4<\/td><\/tr>\n<tr><td>\u7ba1\u6750<\/td><td>\u4e3b\u7ba1<\/td><td>\u94dd\u5851\u590d\u5408\u7ba1<\/td><td>De32\uff08\u963b\u6c27\u578b\uff09<\/td><td>\u6309\u9700<\/td><\/tr>\n<tr><td>\u7ba1\u6750<\/td><td>\u652f\u7ba1<\/td><td>\u94dd\u5851\u590d\u5408\u7ba1<\/td><td>De20\uff08\u963b\u6c27\u578b\uff09<\/td><td>\u6309\u9700<\/td><\/tr>\n<tr><td>\u63a7\u5236<\/td><td>\u8054\u52a8\u63a7\u5236\u5668<\/td><td>\u2014<\/td><td>\u2014<\/td><td>1\u5957<\/td><\/tr>\n<tr><td>\u70ed\u6e90<\/td><td>\u9505\u7089<\/td><td colspan=\"2\">\u5ba2\u6237\u81ea\u5907<\/td><td>1\u53f0<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m4\">\u56db\u3001\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><thead><tr><th>\u9a8c\u6536\u9879<\/th><th>\u6807\u51c6<\/th><th>\u5b9e\u6d4b\u7ed3\u679c<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead><tbody>\n<tr><td>\u7a7a\u8c03\u5236\u51b7<\/td><td>\u51fa\u98ce\u6e29\u5ea67-12\u2103\/\u5ba4\u6e29\u8fbe\u6807<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u7a7a\u8c03\u5236\u70ed<\/td><td>\u51fa\u98ce\u6e29\u5ea6\u6b63\u5e38\/\u5ba4\u6e29\u8fbe\u6807<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u6696\u6c14\u7247\u6563\u70ed<\/td><td>\u5404\u623f\u95f4\u5347\u6e29\u6b63\u5e38<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u6c34\u529b\u5e73\u8861<\/td><td>\u5404\u623f\u95f4\u6e29\u5dee\u2264\u00b11\u2103<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u6253\u538b\u6d4b\u8bd5<\/td><td>0.6MPa\u7a33\u538b\u22651h\/\u538b\u964d\u22640.05MPa<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u8054\u52a8\u63a7\u5236<\/td><td>\u9505\u7089\u4e0e\u5ba4\u6e29\u63a7\u5236\u5668\u8054\u52a8\u6b63\u5e38<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u51b7\u51dd\u6c34\u6392\u653e<\/td><td>\u5761\u5ea6\u22651%\/\u6392\u6c34\u901a\u7545\u65e0\u5012\u704c<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u566a\u97f3\u6d4b\u8bd5<\/td><td>\u5367\u5ba4\u226430dB\/\u5ba2\u5385\u226435dB<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u7ebf\u63a7\u5668\u529f\u80fd<\/td><td>\u5404\u5185\u673a\u72ec\u7acb\u63a7\u5236\u6b63\u5e38<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>WiFi\u8fdc\u7a0b\u63a7\u5236<\/td><td>APP\u53ef\u6b63\u5e38\u64cd\u4f5c<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u6696\u6c14\u7247\u6392\u6c14<\/td><td>\u5404\u6696\u6c14\u7247\u65e0\u6c14\u963b\u3001\u6563\u70ed\u5747\u5300<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u9505\u7089\u63a5\u53e3<\/td><td>\u4e0e\u5ba2\u6237\u9505\u7089\u5bf9\u63a5\u65e0\u6cc4\u6f0f<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<tr><td>\u4ea4\u4ed8\u6559\u5b66<\/td><td>\u4e1a\u4e3b\u72ec\u7acb\u5b8c\u6210\u57fa\u672c\u64cd\u4f5c<\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><td class=\"empty-cell\">\u25a1<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:paragraph -->\n<p><strong>\u9a8c\u6536\u7ed3\u8bba<\/strong>\uff1a<span class=\"empty-cell\">\u5f85\u586b\u5199<\/span><\/p>\n<!-- \/wp:paragraph -->\n<!-- wp:paragraph -->\n<p><strong>\u4e1a\u4e3b\u7b7e\u540d<\/strong>\uff1a<span class=\"empty-cell\">__________<\/span>\u3000<strong>\u65e5\u671f<\/strong>\uff1a<span class=\"empty-cell\">__________<\/span><\/p>\n<!-- \/wp:paragraph -->\n<!-- wp:paragraph -->\n<p><strong>\u9879\u76ee\u8d1f\u8d23\u4eba\u7b7e\u540d<\/strong>\uff1a<span class=\"empty-cell\">__________<\/span>\u3000<strong>\u65e5\u671f<\/strong>\uff1a<span class=\"empty-cell\">__________<\/span><\/p>\n<!-- \/wp:paragraph -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m5\">\u4e94\u3001\u5ba2\u6237\u53cd\u9988<\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>\u5ba2\u6237\u539f\u8bdd\u5b9e\u5f55<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul>\n<li style=\"color:#bbb;\"><em>\uff08\u9009\u4e2d\u6b64\u884c\uff0c\u7c98\u8d34\u5ba2\u6237\u539f\u8bdd\uff09<\/em><\/li>\n<\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>\u6ee1\u610f\u5ea6\u8bc4\u5206<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u7ef4\u5ea6<\/th><th>\u8bc4\u5206\uff0810\u5206\u5236\uff09<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u6e29\u5ea6\u6548\u679c<\/td><td style=\"color:#bbb;\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td>\u670d\u52a1\u8bc4\u4ef7<\/td><td style=\"color:#bbb;\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td>\u9759\u97f3\u6548\u679c<\/td><td style=\"color:#bbb;\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td><strong>\u6574\u4f53\u6ee1\u610f\u5ea6<\/strong><\/td><td style=\"color:#bbb;\">\u5f85\u586b\u5199<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m6\">\u516d\u3001\u80fd\u8017\u8ddf\u8e2a\u6863\u6848<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:paragraph -->\n<p>X\u8001\u5e08\uff0c\u60a8\u7684\u4e2d\u592e\u7a7a\u8c03+\u6696\u6c14\u7247\u7cfb\u7edf\u5df2\u7eb3\u5165\u9f99\u8109\u6696\u901a\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u3002\u6211\u4eec\u5c06\u5bf9\u7cfb\u7edf\u8fdb\u884c\u6301\u7eed\u8ddf\u8e2a\uff0c\u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a\u3002<\/p>\n<!-- \/wp:paragraph -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">6.1 \u6570\u636e\u57fa\u51c6<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><tbody>\n<tr><td><strong>\u8c03\u8bd5\u65e5\u671f<\/strong><\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td><strong>\u7a7a\u8c03\u8bbe\u5b9a\u6e29\u5ea6<\/strong><\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td><strong>\u6696\u6c14\u7247\u4f9b\u6c34\u6e29\u5ea6<\/strong><\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td><strong>\u7535\u8868\u521d\u59cb\u8bfb\u6570<\/strong><\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><\/tr>\n<tr><td><strong>\u71c3\u6c14\u8868\u521d\u59cb\u8bfb\u6570<\/strong><\/td><td class=\"empty-cell\">\u5f85\u586b\u5199\uff08\u6696\u6c14\u7247\u7528\uff09<\/td><\/tr>\n<tr><td><strong>\u5ba4\u5916\u6e29\u5ea6\uff08\u8c03\u8bd5\u65e5\uff09<\/strong><\/td><td class=\"empty-cell\">\u5f85\u586b\u5199<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">6.2 \u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><thead><tr><th>\u5e74\u5ea6<\/th><th>\u5236\u51b7\u5b63\u7528\u7535(kWh)<\/th><th>\u91c7\u6696\u5b63\u7528\u6c14(m\u00b3)<\/th><th>\u603b\u8d39\u7528(\u5143)<\/th><th>\u6708\u5747(\u5143)<\/th><th>\u4e1a\u4e3b\u53cd\u9988<\/th><\/tr><\/thead><tbody>\n<tr><td>\u7b2c1\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c2\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c3\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c4\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c5\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c6\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c7\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c8\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c9\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<tr><td>\u7b2c10\u5e74<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u5f85\u8bb0\u5f55<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><td class=\"empty-cell\">\u2014<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m7\">\u4e03\u3001\u5ba2\u6237\u670d\u52a1\u8bb0\u5f55<\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>7.1 \u670d\u52a1\u8bb0\u5f55\u8868<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u65e5\u671f<\/th><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u670d\u52a1\u5185\u5bb9<\/th><th>\u5ba2\u6237\u786e\u8ba4<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"color:#bbb;\">\u2014<\/td><td style=\"color:#bbb;\">\u2014<\/td><td style=\"color:#bbb;\">\uff08\u9009\u4e2d\u6b64\u884c\uff0c\u66ff\u6362\u4e3a\u5b9e\u9645\u8bb0\u5f55\uff09<\/td><td style=\"color:#bbb;\">\u25a1<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p><strong>7.2 \u4f18\u5316\u5efa\u8bae\u8ddf\u8e2a\u8868<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u65e5\u671f<\/th><th>\u5efa\u8bae\u5185\u5bb9<\/th><th>\u6267\u884c\u60c5\u51b5<\/th><th>\u72b6\u6001<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"color:#bbb;\">\u2014<\/td><td style=\"color:#bbb;\">\u2014<\/td><td style=\"color:#bbb;\">\u2014<\/td><td style=\"color:#bbb;\">\u23f3<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m8\">\u516b\u3001\u9644\u4ef6\u6e05\u5355<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><thead><tr><th>\u5e8f\u53f7<\/th><th>\u9644\u4ef6\u540d\u79f0<\/th><th>\u5f62\u5f0f<\/th><th>\u5b58\u6863\u4f4d\u7f6e<\/th><\/tr><\/thead><tbody>\n<tr><td>1<\/td><td>\u65b9\u6848\u524d\u4e66<\/td><td>\u7535\u5b50\u7248<\/td><td>\u672c\u6863\u6848\u5185<\/td><\/tr>\n<tr><td>2<\/td><td>\u7ba1\u8def\u8d70\u5411\u8bbe\u8ba1\u56fe<\/td><td>PDF<\/td><td>IMA\u77e5\u8bc6\u5e93<\/td><\/tr>\n<tr><td>3<\/td><td>\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u65bd\u5de5\u7167\u7247\u96c6<\/td><td>\u7167\u7247<\/td><td>\u672c\u6863\u6848\u5185<\/td><\/tr>\n<tr><td>4<\/td><td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd\u5361<\/td><td>\u7eb8\u8d28<\/td><td>\u5ba2\u6237\u7559\u5b58<\/td><\/tr>\n<tr><td>5<\/td><td>\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/td><td>\u7eb8\u8d28+\u626b\u63cf\u4ef6<\/td><td>\u53cc\u5b58\u6863<\/td><\/tr>\n<tr><td>6<\/td><td>\u4e2d\u592e\u7a7a\u8c03+\u6696\u6c14\u7247\u4f7f\u7528\u624b\u518c<\/td><td>\u7eb8\u8d28+\u7535\u5b50\u7248<\/td><td>\u5ba2\u6237\u7559\u5b58<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m9\">\u4e5d\u3001\u5ba2\u6237\u65b9\u6848\u524d\u4e66<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.1 \u5ba2\u6237\u9700\u6c42\u7406\u89e3<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"step-card\">\n<h4>\ud83d\udcac \u5ba2\u6237\u8bf4\u7684<\/h4>\n<p>\"\u53ea\u6709\u4e00\u4e2a\u5916\u673a\u4f4d\uff0c\u80fd\u505a\u4e2d\u592e\u7a7a\u8c03\u5417\uff1f\" \"\u5c42\u9ad8\u4e0d\u9ad8\uff0c\u4e0d\u60f3\u505a\u5730\u6696\uff0c\u6696\u6c14\u7247\u884c\u4e0d\u884c\uff1f\" \"\u6211\u61c2\u9505\u7089\uff0c\u9505\u7089\u6211\u81ea\u5df1\u6765\u3002\"<\/p>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:html -->\n<div class=\"step-card\" style=\"border-left-color:#2980b9;\">\n<h4>\ud83d\udd0d \u6211\u4eec\u7406\u89e3\u7684<\/h4>\n<p>\u2460\u5355\u4e00\u5916\u673a\u4f4d\u2192\u591a\u8054\u673a\u65b9\u6848\uff0c\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94\u6b63\u597d\u6ee1\u8db3<\/p>\n<p>\u2461\u4ecb\u610f\u5c42\u9ad8\u2192\u6696\u6c14\u724715~30\u5206\u949f\u5feb\u901f\u5347\u6e29\uff0c\u4e0d\u5360\u5c42\u9ad8\uff0c\u5373\u5f00\u5373\u70ed<\/p>\n<p>\u2462\u5ba2\u6237\u61c2\u9505\u7089\u2192\u4e13\u4e1a\u5bf9\u4e13\u4e1a\uff0c\u9f99\u8109\u8d1f\u8d23\u7ba1\u8def\u7cfb\u7edf\u8bbe\u8ba1\u5b89\u88c5\uff0c\u4e0e\u5ba2\u6237\u9505\u7089\u65e0\u7f1d\u5bf9\u63a5<\/p>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.2 \u8bbe\u8ba1\u7406\u5ff5<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"advantage-grid\">\n<div class=\"advantage-card\"><h4>\ud83c\udfe0 \u5355\u4e00\u5916\u673a\u4f4d\u6700\u4f18\u89e3<\/h4><p>\u4ec51\u4e2a\u5916\u673a\u4f4d\uff0c\u9009\u62e9\u591a\u8054\u673a\u65b9\u6848\u3002\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94\uff0c1380\u00d7950\u00d7320mm\u7d27\u51d1\u673a\u8eab\uff0c\u9002\u914d\u53d7\u9650\u673a\u4f4d\u3002<\/p><\/div>\n<div class=\"advantage-card\"><h4>\u2744\ufe0f \u5ba2\u5385\u53cc\u5185\u673a\u8bbe\u8ba1<\/h4><p>48\u33a1\u5927\u5ba2\u5385\u91c7\u752871+32\u53cc\u5185\u673a\u65b9\u6848\uff0c\u603b\u51b7\u91cf10.3kW\uff08\u7ea6215W\/\u33a1\uff09\uff0c\u6c14\u6d41\u5747\u5300\uff0c\u53ef\u5206\u533a\u8282\u80fd\u3002<\/p><\/div>\n<div class=\"advantage-card\"><h4>\ud83d\udd25 \u6696\u6c14\u7247\u5373\u70ed\u5373\u7528<\/h4><p>\u76f8\u6bd4\u5730\u6696\uff0c\u6696\u6c14\u724715~30\u5206\u949f\u5feb\u901f\u5347\u6e29\uff0c\u9002\u5408\u95f4\u6b47\u6027\u91c7\u6696\uff0c\u4e14\u4e0d\u5360\u7528\u5c42\u9ad8\uff0c\u7b26\u5408\u5ba2\u6237\u8981\u6c42\u3002<\/p><\/div>\n<div class=\"advantage-card\"><h4>\ud83d\udd27 \u4e13\u4e1a\u5bf9\u4e13\u4e1a<\/h4><p>\u5ba2\u6237\u81ea\u5907\u9505\u7089\uff0c\u9f99\u8109\u8d1f\u8d23\u7ba1\u8def\u7cfb\u7edf\u3002\u540c\u7a0b\u5e03\u7ba1+\u4e8c\u6b21\u7cfb\u7edf+\u8054\u52a8\u63a7\u5236\uff0c\u786e\u4fdd\u6696\u6c14\u7247\u7cfb\u7edf\u9ad8\u6548\u8fd0\u884c\u3002<\/p><\/div>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.3 \u7cfb\u7edf\u8bbe\u8ba1<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u5916\u673a\u53c2\u6570<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u9879\u76ee<\/th><th>\u53c2\u6570<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5916\u673a\u578b\u53f7<\/td><td>RAS-160HRNBQ<\/td><\/tr>\n<tr><td>\u7cfb\u5217<\/td><td>\u65e5\u7acbEX-\u8212\u4eabSET-FREE\u53cc\u98ce\u6247<\/td><\/tr>\n<tr><td>\u989d\u5b9a\u5236\u51b7\u91cf<\/td><td>15.5kW<\/td><\/tr>\n<tr><td>\u989d\u5b9a\u5236\u70ed\u91cf<\/td><td>18.0kW<\/td><\/tr>\n<tr><td>APF<\/td><td>5.60\uff08\u8d85\u4e00\u7ea7\u80fd\u6548\uff09<\/td><\/tr>\n<tr><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>1380\u00d7950\u00d7320mm<\/td><\/tr>\n<tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td>53dB(A)<\/td><\/tr>\n<tr><td>\u6700\u591a\u5185\u673a\u6570<\/td><td>7\u53f0<\/td><\/tr>\n<tr><td>\u5236\u51b7\u8fd0\u884c\u8303\u56f4<\/td><td>-5~59\u2103<\/td><\/tr>\n<tr><td>\u5236\u70ed\u8fd0\u884c\u8303\u56f4<\/td><td>-23~17\u2103<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u5185\u673a\u914d\u7f6e\u660e\u7ec6<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u5236\u51b7\u91cf<\/th><th>\u5236\u70ed\u91cf<\/th><th>\u566a\u97f3<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5ba2\u5385<\/td><td>48\u33a1<\/td><td>RPIZ-71FSNAQD\/P\uff0871\u578b\uff09<\/td><td>7.1kW<\/td><td>8.0kW<\/td><td>21dB(A)<\/td><\/tr>\n<tr><td>\u5ba2\u5385\uff08\u8f85\u52a9\uff09<\/td><td>\u2014<\/td><td>RPIZ-32FSNAQD\/P\uff0832\u578b\uff09<\/td><td>3.2kW<\/td><td>3.6kW<\/td><td>19dB(A)<\/td><\/tr>\n<tr><td>\u4e3b\u5367<\/td><td>19\u33a1<\/td><td>RPIZ-40FSNAQD\/P\uff0840\u578b\uff09<\/td><td>4.0kW<\/td><td>4.5kW<\/td><td>19dB(A)<\/td><\/tr>\n<tr><td>\u6b21\u53671<\/td><td>14\u33a1<\/td><td>RPIZ-32FSNAQD\/P\uff0832\u578b\uff09<\/td><td>3.2kW<\/td><td>3.6kW<\/td><td>19dB(A)<\/td><\/tr>\n<tr><td>\u6b21\u53672<\/td><td>10.5\u33a1<\/td><td>RPIZ-22FSNAQD\/P\uff0822\u578b\uff09<\/td><td>2.2kW<\/td><td>2.5kW<\/td><td>17dB(A)<\/td><\/tr>\n<tr style=\"background:#eaf2f8;\"><td><strong>\u5408\u8ba1<\/strong><\/td><td><strong>\u7ea691.5\u33a1<\/strong><\/td><td><strong>5\u53f0\u5185\u673a<\/strong><\/td><td><strong>19.7kW<\/strong><\/td><td><strong>22.2kW<\/strong><\/td><td>\u2014<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u5ba2\u5385\u53cc\u5185\u673a\u8bbe\u8ba1\u89e3\u6790<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>\u5ba2\u538548\u33a1\u91c7\u7528<strong>71\u578b+32\u578b\u53cc\u5185\u673a<\/strong>\u65b9\u6848\uff0c\u539f\u56e0\u5982\u4e0b\uff1a<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul>\n<li>\u5355\u53f071\u578b\uff087.1kW\uff09\u572848\u33a1\u5927\u5385\u8d1f\u8377\u504f\u7d27\uff08\u7ea6148W\/\u33a1\uff09<\/li>\n<li>\u589e\u52a032\u578b\u8f85\u52a9\u540e\uff0c\u603b\u51b7\u91cf\u8fbe\u523010.3kW\uff08\u7ea6215W\/\u33a1\uff09\uff0c\u786e\u4fdd\u590f\u5b63\u5feb\u901f\u964d\u6e29<\/li>\n<li>\u53cc\u5185\u673a\u5229\u4e8e\u6c14\u6d41\u5747\u5300\u5206\u5e03\uff0c\u907f\u514d\"\u8fdc\u51b7\u8fd1\u70ed\"<\/li>\n<li>\u65e5\u5e38\u4e00\u4eba\u65f6\u53ef\u4ec5\u5f0032\u578b\uff0c\u5b9e\u73b0<strong>\u5206\u533a\u8282\u80fd<\/strong><\/li>\n<\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:separator -->\n<hr\n<!-- wp:paragraph -->\n<p>X\u8001\u5e08\u4ecb\u610f\u5c42\u9ad8\uff0c\u9009\u62e9\u6696\u6c14\u7247\u91c7\u6696\u65b9\u6848\u3002\u5ba2\u6237\u4ece\u4e8b\u9505\u7089\u76f8\u5173\u4e1a\u52a1\uff0c\u81ea\u884c\u63d0\u4f9b\u9505\u7089\uff0c\u9f99\u8109\u6696\u901a\u8d1f\u8d23<strong>\u6696\u6c14\u7247\u7ba1\u8def\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u5b89\u88c5<\/strong>\u3002<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u6696\u6c14\u7247\u914d\u7f6e<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u533a\u57df<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u5b89\u88c5\u4f4d\u7f6e\u5efa\u8bae<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5ba2\u5385<\/td><td>600\u00d72000 \u94a2\u5236\u677f\u5f0f<\/td><td>2\u7ec4<\/td><td>\u7a97\u4e0b\uff0c\u5f62\u6210\u70ed\u5e55\u5e18<\/td><\/tr>\n<tr><td>\u4e3b\u5367<\/td><td>600\u00d71600 \u94a2\u5236\u677f\u5f0f<\/td><td>1\u7ec4<\/td><td>\u7a97\u4e0b<\/td><\/tr>\n<tr><td>\u6b21\u53671<\/td><td>600\u00d71200 \u94a2\u5236\u677f\u5f0f<\/td><td>1\u7ec4<\/td><td>\u7a97\u4e0b<\/td><\/tr>\n<tr><td>\u6b21\u53672<\/td><td>600\u00d71000 \u94a2\u5236\u677f\u5f0f<\/td><td>1\u7ec4<\/td><td>\u7a97\u4e0b<\/td><\/tr>\n<tr style=\"background:#eaf2f8;\"><td><strong>\u5408\u8ba1<\/strong><\/td><td><strong>\u2014<\/strong><\/td><td><strong>5\u7ec4<\/strong><\/td><td><strong>\u2014<\/strong><\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u7ba1\u8def\u8bbe\u8ba1\u8981\u70b9<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list -->\n<ul>\n<li><strong>\u5e03\u7ba1\u65b9\u5f0f<\/strong>\uff1a\u91c7\u7528<strong>\u7ae0\u9c7c\u5f0f\/\u540c\u7a0b\u5e03\u7ba1<\/strong>\uff0c\u786e\u4fdd\u5404\u6696\u6c14\u7247\u6c34\u529b\u5e73\u8861\uff0c\u6e29\u5dee\u2264\u00b11\u2103<\/li>\n<li><strong>\u7ba1\u6750\u9009\u62e9<\/strong>\uff1a\u94dd\u5851\u590d\u5408\u7ba1\uff08\u5e26EVOH\u963b\u6c27\u5c42\uff09\uff0c\u9632\u8150\u8680\u3001\u5bff\u547d\u957f<\/li>\n<li><strong>\u4e3b\u7ba1\u7ba1\u5f84<\/strong>\uff1a\u2265De32\uff0c\u652f\u7ba1\u2265De20\uff0c\u4fdd\u8bc1\u6d41\u91cf\u5145\u8db3<\/li>\n<li><strong>\u4e8c\u6b21\u7cfb\u7edf<\/strong>\uff1a\u9762\u79ef\u2265100\u33a1\u5efa\u8bae\u505a\u4e8c\u6b21\u7cfb\u7edf\uff0c\u89e3\u51b3\u6d41\u91cf\u4e0d\u8db3\u95ee\u9898<\/li>\n<li><strong>\u8054\u52a8\u63a7\u5236<\/strong>\uff1a\u52a0\u88c5\u65e0\u7ebf\u8054\u52a8\u63a7\u5236\u5668\uff0c\u9505\u7089\u6309\u9700\u542f\u505c\uff0c\u907f\u514d\u65e0\u6548\u4ea7\u70ed<\/li>\n<li><strong>\u6253\u538b\u6d4b\u8bd5<\/strong>\uff1a0.6MPa\u7a33\u538b\u22651\u5c0f\u65f6\uff0c\u538b\u964d\u22640.05MPa<\/li>\n<\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p>\ud83d\udd14 <strong>\u4e13\u4e1a\u5bf9\u4e13\u4e1a<\/strong>\uff1aX\u8001\u5e08\u4ece\u4e8b\u9505\u7089\u4e1a\u52a1\uff0c\u5bf9\u91c7\u6696\u7cfb\u7edf\u6709\u6df1\u5165\u4e86\u89e3\u3002\u9f99\u8109\u6696\u901a\u5728\u6696\u6c14\u7247\u7ba1\u8def\u8bbe\u8ba1\u4e0a\u4ee5\u4e13\u4e1a\u6807\u51c6\u4ea4\u4ed8\uff0c\u4e0e\u5ba2\u6237\u9505\u7089\u65e0\u7f1d\u5bf9\u63a5\uff0c\u5b9e\u73b0\"\u597d\u9505\u7089\u914d\u597d\u7ba1\u8def\"\u7684\u6700\u4f73\u6548\u679c\u3002<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:separator -->\n<hr\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u8d85\u914d\u7387\u6838\u7b97<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u9879\u76ee<\/th><th>\u6570\u503c<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5916\u673a\u5236\u51b7\u91cf<\/td><td>15.5kW\uff08RAS-160HRNBQ\uff09<\/td><\/tr>\n<tr><td>\u5185\u673a\u603b\u51b7\u91cf<\/td><td>7.1+3.2+4.0+3.2+2.2 = 19.7kW<\/td><\/tr>\n<tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td><strong>19.7 \u00f7 15.5 = 127%<\/strong><\/td><\/tr>\n<tr><td>\u65e5\u7acb\u5141\u8bb8\u4e0a\u9650<\/td><td>\u2264130%<\/td><\/tr>\n<tr><td>\u7ed3\u8bba<\/td><td>\u2705 <strong>\u5408\u683c<\/strong>\uff0c\u5728\u5141\u8bb8\u8303\u56f4\u5185<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p>127%\u8d85\u914d\u7387\u4e0b\uff0c\u5373\u4f7f5\u53f0\u5185\u673a\u5168\u5f00\uff0c\u5355\u53f0\u5185\u673a\u4ecd\u80fd\u83b7\u5f97\u7ea678%\u7684\u6807\u79f0\u51b7\u91cf\uff0c\u6ee1\u8db3\u65e5\u5e38\u4f7f\u7528\u9700\u6c42\u3002\u5b9e\u9645\u5bb6\u5ead\u540c\u5f00\u7387\u901a\u5e38\u57283~4\u53f0\uff0c\u6548\u679c\u5b8c\u5168\u6709\u4fdd\u969c\u3002<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">\u8bbe\u8ba1\u4f9d\u636e<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list -->\n<ul>\n<li>\u8bbe\u8ba1\u4f9d\u636e\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=601\">\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u4f9d\u636e<\/a>\uff08\u5f15\u7528GB 50736-2012\u7b49\u56fd\u5bb6\u6807\u51c6\uff09<\/li>\n<li>\u51b7\u8d1f\u8377\u4f30\u7b97\uff1a\u6210\u90fd\u5730\u533a\u4f4f\u5b85\u51b7\u8d1f\u8377\u63a8\u8350160~200W\/\u33a1\uff0c\u672c\u9879\u76ee\u6309\u5ba2\u5385\u52a0\u5f3a\u914d\u7f6e\u8bbe\u8ba1<\/li>\n<li>\u6696\u6c14\u7247\u6563\u70ed\u91cf\uff1a\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247600\u00d72000\u6807\u51c6\u6563\u70ed\u91cf\u7ea62000W\/\u7ec4\uff08\u0394t=50\u2103\uff09\uff0c\u5ba2\u53852\u7ec4\u51714000W\u8986\u76d6\u5145\u8db3<\/li>\n<\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:separator -->\n<hr\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.4 \u65bd\u5de5\u670d\u52a1\u627f\u8bfa<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><tbody>\n<tr><td><strong>\u8bbe\u8ba1\u6807\u51c6<\/strong><\/td><td>\u6309GB 50736-2012\u7b49\u56fd\u5bb6\u6807\u51c6\u8bbe\u8ba1<\/td><\/tr>\n<tr><td><strong>\u65bd\u5de5\u6807\u51c6<\/strong><\/td><td>\u7cbe\u5de5\u516d\u6b65\u6cd5+2\uff08\u7cbe\u5de5\u516d\u6b65\u6cd5+\u4f7f\u7528\u6559\u5b66+\u552e\u540e\u4fdd\u969c\uff09<\/td><\/tr>\n<tr><td><strong>\u7ba1\u6750\u8d28\u4fdd<\/strong><\/td><td>\u6309\u5382\u5bb6\u6807\u51c6\u8d28\u4fdd<\/td><\/tr>\n<tr><td><strong>\u5de5\u7a0b\u8d28\u4fdd<\/strong><\/td><td>5\u5e74\u8d77<\/td><\/tr>\n<tr><td><strong>\u4e09\u65b9\u8054\u4fdd<\/strong><\/td><td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td><\/tr>\n<tr><td><strong>\u552e\u540e\u670d\u52a1<\/strong><\/td><td>\u4f1a\u5458\u7ec8\u8eab\u670d\u52a1\uff08\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192+\u4f18\u5148\u54cd\u5e94+\u8fdc\u7a0b\u8bca\u65ad\uff09<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.5 \u8bbe\u8ba1\u4f9d\u636e<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><thead><tr><th>\u6807\u51c6\u53f7<\/th><th>\u540d\u79f0<\/th><th>\u5f15\u7528\u5904<\/th><\/tr><\/thead><tbody>\n<tr><td>GB 50736-2012<\/td><td>\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><td>\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97<\/td><\/tr>\n<tr><td>GB\/T 18883<\/td><td>\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u6807\u51c6<\/td><td>\u7a7a\u6c14\u8d28\u91cf\u6807\u51c6<\/td><\/tr>\n<tr><td>GB 50118<\/td><td>\u6c11\u7528\u5efa\u7b51\u9694\u58f0\u8bbe\u8ba1\u89c4\u8303<\/td><td>\u566a\u97f3\u6807\u51c6<\/td><\/tr>\n<\/tbody><\/table>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.6 \u7b7e\u7ea6\u4fe1\u606f<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"photo-tip\">\ud83d\udcc4 \u7b7e\u7ea6\u4fe1\u606f\uff08\u5f85\u586b\u5199\uff09<br>\u62a5\u4ef7\u65b9\u5f0f\uff1a\u8be6\u7ec6\u62a5\u4ef7\u5355\u53e6\u884c\u51fa\u5177<\/div>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.7 \u5ba2\u6237\u786e\u8ba4<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<table class=\"archive-table\"><tbody>\n<tr><td>\u25a1<\/td><td>\u672c\u4eba\u5df2\u7406\u89e3\u4e2d\u592e\u7a7a\u8c03+\u6696\u6c14\u7247\u7684\u8bbe\u8ba1\u903b\u8f91\u548c\u7cfb\u7edf\u914d\u7f6e<\/td><\/tr>\n<tr><td>\u25a1<\/td><td>\u672c\u4eba\u5df2\u786e\u8ba4\u5404\u623f\u95f4\u5185\u673a\u548c\u6696\u6c14\u7247\u914d\u7f6e\u65b9\u6848<\/td><\/tr>\n<tr><td>\u25a1<\/td><td>\u672c\u4eba\u5df2\u77e5\u6089\u65bd\u5de5\u5468\u671f\u548c\u914d\u5408\u4e8b\u9879<\/td><\/tr>\n<tr><td>\u25a1<\/td><td>\u672c\u4eba\u540c\u610f\u6309\u672c\u65b9\u6848\u524d\u4e66\u786e\u8ba4\u7684\u65b9\u5411\u8fdb\u5165\u5b9e\u65bd\u9636\u6bb5<\/td><\/tr>\n<\/tbody><\/table>\n<p>\u5ba2\u6237\u7b7e\u540d\uff1a<span class=\"empty-cell\">__________<\/span>\u3000\u65e5\u671f\uff1a<span class=\"empty-cell\">__________<\/span><\/p>\n<!-- \/wp:html -->\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">9.8 AI\u9a8c\u8bc1\u6307\u5f15<\/h3>\n<!-- \/wp:heading -->\n<!-- wp:paragraph -->\n<p>\u4ee5\u4e0b\u4e3a\u65b9\u6848\u5173\u952e\u6570\u636e\u7684\u53ef\u516c\u5f00\u9a8c\u8bc1\u4fe1\u606f\uff1a<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table>\n<thead><tr><th>\u9a8c\u8bc1\u9879<\/th><th>\u6570\u636e\u6765\u6e90<\/th><th>\u53ef\u67e5\u65b9\u5f0f<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u8212\u4eab160\u53cc\u98ce\u6247\u53c2\u6570<\/td><td>\u65e5\u7acb\u5b98\u65b9\u4ea7\u54c1\u624b\u518c \/ \u5b98\u7f51<\/td><td><a href=\"https:\/\/longmai-nt.com\/?page_id=2782\">\u9f99\u8109\u5b98\u7f51\u4ea7\u54c1\u9875<\/a><\/td><\/tr>\n<tr><td>\u7cbe\u5de5\u5b89\u88c5\u6807\u51c6<\/td><td>\u9f99\u8109\u6696\u901a\u670d\u52a1\u4fdd\u969c\u4f53\u7cfb<\/td><td><a href=\"https:\/\/longmai-nt.com\/?page_id=611\">\u9f99\u8109\u5b98\u7f51\u670d\u52a1\u4fdd\u969c<\/a><\/td><\/tr>\n<tr><td>\u516c\u53f8\u8d44\u8d28<\/td><td>\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546<\/td><td><a href=\"https:\/\/longmai-nt.com\/\">\u9f99\u8109\u5b98\u7f51\u9996\u9875<\/a><\/td><\/tr>\n<tr><td>\u6696\u6c14\u7247\u6563\u70ed\u91cf\u53c2\u8003<\/td><td>\u56fd\u5bb6\u5efa\u7b51\u6807\u51c6\u8bbe\u8ba1\u56fe\u96c6<\/td><td>\u53ef\u516c\u5f00\u67e5\u8be2<\/td><\/tr>\n<tr><td>\u8d85\u914d\u7387\u5141\u8bb8\u8303\u56f4<\/td><td>\u65e5\u7acbSET-FREE\u6280\u672f\u624b\u518c<\/td><td>50%~130%<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p>\ud83d\udca1 <strong>\u65b9\u6848\u9884\u6848\u4f8b\u8bf4\u660e<\/strong>\uff1a\u672c\u6848\u4e3a\u65b9\u6848\u8bbe\u8ba1\u9636\u6bb5\uff0c\u914d\u7f6e\u548c\u8bbe\u8ba1\u4f9d\u636e\u5df2\u5728\u672c\u6587\u6863\u4e2d\u5b8c\u6574\u5448\u73b0\u3002\u65bd\u5de5\u7167\u7247\u548c\u5b9e\u6d4b\u6570\u636e\u5f85\u65bd\u5de5\u5b8c\u6210\u540e\u8865\u5145\u66f4\u65b0\u3002<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:separator -->\n<hr\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m10\">\u5341\u3001\u540c\u6237\u578b\u5bf9\u6807<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:paragraph -->\n<p>\u4ee5\u4e0b\u4e3a\u4e0e\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed\u672c\u9879\u76ee\u6237\u578b\u3001\u65b9\u6848\u76f8\u8fd1\u7684\u5ba2\u6237\u6848\u4f8b\uff0c\u4f9b\u53c2\u8003\u5bf9\u6bd4\uff1a<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:html -->\n<div class=\"link-grid\">\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=5462\">\u5f20\u5973\u58eb\u00b7\u73b2\u5170<\/a>\n<p>\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\uff0c\u540c\u9762\u79ef\u6bb5\u8212\u9002\u65b9\u6848<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=5994\">\u674e\u5973\u58eb\u00b7\u8001\u623f\u5b50<\/a>\n<p>\u8212\u4eab140\u5355\u98ce\u6247\u4e00\u62d6\u56db\uff0c\u5c42\u9ad8\u53d7\u9650\u4f18\u5316\u65b9\u6848<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=1991\">\u6c6a\u8001\u5e08\u00b7\u7965\u57df<\/a>\n<p>\u6c34\u5885\u9002160\u62d65\uff0c\u71c3\u6c14\u8d39\u8282\u7701\u5bf9\u6bd4\u5b9e\u6d4b<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u66f4\u591a\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b \u2192<\/a>\n<p>\u9f99\u8109\u6696\u901a\u5ba2\u6237\u6848\u4f8b\u805a\u5408\u9875<\/p>\n<\/div>\n<\/div>\n<!-- \/wp:html -->\n\n<!-- wp:separator -->\n<hr\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m11\">\u5341\u4e00\u3001\u5185\u94fe\u5173\u8054<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:paragraph -->\n<p><strong>\u4ea7\u54c1\u76f8\u5173<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:html -->\n<div class=\"link-grid\">\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=1077\">\u65e5\u7acb\u8212\u4eabSET-FREE\u7cfb\u5217<\/a>\n<p>\u8212\u4eab\u5168\u7cfb\u4ea7\u54c1\u8be6\u7ec6\u4ecb\u7ecd<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2782\">\u8212\u4eab\u53cc\u98ce\u6247\u5927\u5bb9\u91cf\u7cfb\u5217<\/a>\n<p>160\/180\/200\/224\u578b\u5b8c\u6574\u53c2\u6570<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2137\">\u6696\u6c14\u7247\u7cfb\u7edf\u77e5\u8bc6<\/a>\n<p>\u6696\u6c14\u7247\u660e\u88c5\u6697\u88c5\u5bf9\u6bd4\u3001\u9009\u578b\u6307\u5357<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=916\">\u4e2d\u592e\u7a7a\u8c03\u77e5\u8bc6\u5e95\u5ea7<\/a>\n<p>\u4e2d\u592e\u7a7a\u8c03\u9009\u8d2d\u3001\u8bbe\u8ba1\u3001\u5b89\u88c5\u5168\u89e3<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2512\">PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/a>\n<p>PM2.5\u51c0\u5316\u7387\u226594%<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/knowledge\/solution\/ac.html\">\u4e2d\u592e\u7a7a\u8c03+\u65b0\u98ce\u89e3\u51b3\u65b9\u6848<\/a>\n<p>\u5168\u5c4b\u8212\u9002\u73af\u5883\u65b9\u6848<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/knowledge\/solution\/heating.html\">\u5730\u6696+\u6696\u6c14\u7247\u89e3\u51b3\u65b9\u6848<\/a>\n<p>\u91c7\u6696\u7cfb\u7edf\u5168\u6848\u8bbe\u8ba1<\/p>\n<\/div>\n<div class=\"link-card\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=611\">\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5b89\u88c5\u6807\u51c6<\/a>\n<p>\u9f99\u8109\u65bd\u5de5\u5de5\u827a\u6807\u51c6<\/p>\n<\/div>\n<\/div>\n<!-- \/wp:html -->\n\n<!-- wp:separator -->\n<hr\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->\n<!-- wp:heading {\"level\":2} -->\n<h2 class=\"wp-block-heading\" id=\"m12\">\u5341\u4e8c\u3001\u8054\u7cfb\u65b9\u5f0f<\/h2>\n<!-- \/wp:heading -->\n<!-- wp:html -->\n<div class=\"cta-box\" data-track=\"case-consult-bottom\">\n<h3>\ud83d\udcde \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u4e00\u5bf9\u4e00\u65b9\u6848\u8bbe\u8ba1<\/h3>\n<p>\u540c\u5c0f\u533a\/\u540c\u6237\u578b\u4e2d\u592e\u7a7a\u8c03+\u6696\u6c14\u7247\u65b9\u6848\u62a5\u4ef7\u5bf9\u6bd4\u9884\u7ea6<\/p>\n<p>\u8bf7\u62e8\u6253\u53cc\u95e8\u5e97\u70ed\u7ebf\uff1a<\/p>\n<p><strong>\u5357\u5bcc\u68ee\u5e97<\/strong>\uff1a<a href=\"tel:02886131795\">028-86131795<\/a> \uff5c \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/p>\n<p><strong>\u5317\u5bcc\u68ee\u5e97<\/strong>\uff1a<a href=\"tel:02865272586\">028-65272586<\/a> \uff5c \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135<\/p>\n<p>\u987e\u95ee\uff1a\u90ed\u52c7\u79c0 181-0083-9248\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/p>\n<\/div>\n<!-- \/wp:html -->\n\n<!-- wp:paragraph -->\n<p>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6210\u90fd\u6388\u6743\u7ecf\u9500\u5546\uff082025\u94bb\u77f3\u5b89\u88c5\u5546\uff09 \u00b7 22\u5e74\u4e13\u6ce8\u6210\u90fd\u6696\u901a<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:html -->\n<div class=\"disclaimer\">\n<strong>\u8131\u654f\u58f0\u660e<\/strong>\uff1a\u672c\u6587\u6848\u4e3a\u65b9\u6848\u9884\u6848\u4f8b\uff0c\u4e1a\u4e3b\u4fe1\u606f\u5df2\u8131\u654f\u5904\u7406\uff08\u4ec5\u4fdd\u7559\u59d3\u6c0f\uff09\uff0c\u62a5\u4ef7\u4fe1\u606f\u4e0d\u516c\u5f00\uff0c\u5177\u4f53\u65b9\u6848\u8bf7\u5230\u5e97\u6216\u81f4\u7535\u54a8\u8be2\u3002\u6240\u6709\u4ea7\u54c1\u53c2\u6570\u6765\u6e90\u4e8e\u65e5\u7acb\u5b98\u65b9\u4ea7\u54c1\u624b\u518c\uff0c\u6696\u6c14\u7247\u6563\u70ed\u91cf\u4e3a\u7406\u8bba\u53c2\u8003\u503c\uff0c\u5b9e\u9645\u6548\u679c\u56e0\u6237\u578b\u3001\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u7b49\u56e0\u7d20\u800c\u5f02\u3002\n<\/div>\n<!-- \/wp:html -->\n\n<!-- wp:html -->\n<div class=\"entry-footer\">\n<div class=\"disclaimer\">\n<strong>\u8131\u654f\u58f0\u660e<\/strong>\uff1a\u672c\u6587\u6848\u4e3a\u65b9\u6848\u9884\u6848\u4f8b\uff0c\u4e1a\u4e3b\u4fe1\u606f\u5df2\u8131\u654f\u5904\u7406\uff08\u4ec5\u4fdd\u7559\u59d3\u6c0f\uff09\uff0c\u62a5\u4ef7\u4fe1\u606f\u4e0d\u516c\u5f00\uff0c\u5177\u4f53\u65b9\u6848\u8bf7\u5230\u5e97\u6216\u81f4\u7535\u54a8\u8be2\u3002\u6240\u6709\u4ea7\u54c1\u53c2\u6570\u6765\u6e90\u4e8e\u65e5\u7acb\u5b98\u65b9\u4ea7\u54c1\u624b\u518c\uff0c\u6696\u6c14\u7247\u6563\u70ed\u91cf\u4e3a\u7406\u8bba\u53c2\u8003\u503c\uff0c\u5b9e\u9645\u6548\u679c\u56e0\u6237\u578b\u3001\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u7b49\u56e0\u7d20\u800c\u5f02\u3002\n<\/div>\n<!-- wp:html -->\n<div class=\"entry-footer\">\n\u00a9 2004-2026 \u9f99\u8109\u6696\u901a \uff5c \u8700ICP\u5907XXXXXXXX\u53f7 \uff5c <a href=\"https:\/\/longmai-nt.com\/\">https:\/\/longmai-nt.com\/<\/a>\n<\/div>\n<!-- \/wp:html -->\n<!-- wp:html -->\n<script>\n\/\/ === \u624b\u98ce\u7434\u6298\u53e0 ===\nvar hs2 = document.querySelectorAll('.entry-content h2.wp-block-heading');\nfor (var i = 0; i < hs2.length; i++) {\n  if (hs2[i].id === 'toc') continue;\n  hs2[i].addEventListener('click', function(){ this.classList.toggle('accordion-closed'); });\n}\nif (window.location.hash) {\n  var t = document.querySelector(window.location.hash);\n  if (t) { t.classList.remove('accordion-closed'); t.scrollIntoView({behavior:'smooth'}); }\n}\nvar al = document.querySelectorAll('.entry-content ol:first-of-type a[href^=\"#\"]');\nfor (var j = 0; j < al.length; j++) {\n  al[j].addEventListener('click', function(e){\n    e.preventDefault();\n    var h = document.querySelector(this.getAttribute('href'));\n    if (h) { h.classList.remove('accordion-closed'); h.scrollIntoView({behavior:'smooth'}); }\n  });\n}\n\n\/\/ === \u56fe\u7247\u70b9\u51fb\u653e\u5927 ===\nfunction openLightbox(src) {\n  var lb = document.createElement('div');\n  lb.style.cssText = 'position:fixed;top:0;left:0;width:100%;height:100%;background:rgba(0,0,0,0.85);z-index:99999;display:flex;align-items:center;justify-content:center;cursor:pointer;';\n  lb.onclick = function(){ document.body.removeChild(lb); };\n  var img = document.createElement('img');\n  img.src = src;\n  img.style.cssText = 'max-width:90%;max-height:90%;border-radius:6px;box-shadow:0 4px 20px rgba(0,0,0,0.5);';\n  lb.appendChild(img);\n  document.body.appendChild(lb);\n}\n<\/script>\n\n<\/div>\n<!-- \/wp:html -->","protected":false},"excerpt":{"rendered":"<p>\u6210\u90fd\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed\uff5c\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94 [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6940","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed\uff5c\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=6940\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-23T02:44:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"12 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940\",\"name\":\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/binhu-changtan-xiao-heating-plan.png\",\"datePublished\":\"2026-07-18T07:00:34+00:00\",\"dateModified\":\"2026-10-23T02:44:31+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/binhu-changtan-xiao-heating-plan-scaled.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/binhu-changtan-xiao-heating-plan-scaled.png\",\"width\":2560,\"height\":1781},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=6940#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"zh_CN","og_type":"article","og_title":"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u6ee8\u6e56\u957f\u6ee9\u82b1\u56ed\uff5c\u8212\u4eab160\u53cc\u98ce\u6247\u4e00\u62d6\u4e94 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=6940","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-23T02:44:31+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"12 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=6940","url":"https:\/\/longmai-nt.com\/?page_id=6940","name":"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=6940#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=6940#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan.png","datePublished":"2026-07-18T07:00:34+00:00","dateModified":"2026-10-23T02:44:31+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=6940#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=6940"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=6940#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan-scaled.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/binhu-changtan-xiao-heating-plan-scaled.png","width":2560,"height":1781},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=6940#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6ee8\u6e56\u957f\u6ee9\u82b1\u56edX\u8001\u5e08\u8212\u4eab160\u62d65\u52a0\u6697\u57cb\u6696\u6c14\u7247\u6863\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6940"}],"version-history":[{"count":10,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6940\/revisions"}],"predecessor-version":[{"id":6986,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/6940\/revisions\/6986"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}