{"id":7249,"date":"2026-07-20T08:48:23","date_gmt":"2026-07-20T00:48:23","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=7249"},"modified":"2026-07-20T08:48:23","modified_gmt":"2026-07-20T00:48:23","slug":"%e5%85%a8%e5%b1%8b%e6%9a%96%e9%80%9a%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e4%b9%a6%e6%a8%a1%e7%89%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=7249","title":{"rendered":"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248"},"content":{"rendered":"\n\n<style>\n\/* ===== \u6697\u8272\u91d1 UI \u4f53\u7cfb \u53d8\u91cf ===== *\/\n:root{\n  --lm-bg:#f6f3ec;          \/* \u6e05\u65b0\u7c73\u767d\u9875\u9762\u80cc\u666f *\/\n  --lm-bg2:#ffffff;         \/* \u5361\u7247\u80cc\u666f \u7eaf\u767d *\/\n  --lm-bg3:#f1ebdc;         \/* \u6d45\u7c73\u5757\/\u8868\u5934 *\/\n  --lm-bg4:#faf6ec;         \/* hover\/\u6d45\u5757 *\/\n  --lm-gold:#c89b3c;        \/* \u4e3b\u91d1\uff08\u6e05\u65b0\u67d4\u91d1\uff09 *\/\n  --lm-gold2:#9a7414;       \/* \u6df1\u91d1\uff08\u6d45\u5e95\u6807\u9898\u53ef\u8bfb\uff09 *\/\n  --lm-gold3:#b8860b;       \/* \u6697\u91d1 *\/\n  --lm-on-gold:#2e2616;     \/* \u91d1\u5e95\u6df1\u8272\u5b57 *\/\n  --lm-text:#3a3326;        \/* \u4e3b\u6587\u5b57 \u70ad\u68d5 *\/\n  --lm-text2:#7c7060;       \/* \u6b21\u6587\u5b57 *\/\n  --lm-border:#e6dfcd;      \/* \u8fb9\u6846 \u6d45\u7c73 *\/\n  --lm-red:#c0392b;         \/* \u5916\u94fe\u7ea2\uff08GEO\u89c4\u8303\uff09 *\/\n  --lm-green:#3f8f5f;       \/* \u4f18\u826f\/\u901a\u8fc7 *\/\n  --lm-orange:#c07d2e;      \/* \u6ce8\u610f *\/\n}\n\n\/* ===== \u5168\u5c40\u91cd\u7f6e ===== *\/\n*, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }\nhtml { scroll-behavior: smooth; }\nbody { font-family: -apple-system, \"Microsoft YaHei\", \"PingFang SC\", sans-serif; color: var(--lm-text); background: var(--lm-bg); line-height: 1.8; }\n\n\/* \u9690\u85cf WP \u81ea\u52a8\u751f\u6210\u7684\u6807\u9898 H1\uff0c\u4ec5\u4fdd\u7559\u5c01\u9762 H1\uff08F1\u4fee\u590d\uff09 *\/\n.entry-title { display: none !important; }\n\n\/* ===== \u56fa\u5b9a\u5bfc\u822a ===== *\/\n.lm-toc-bar {\n  position: sticky; top: 80px; z-index: 1000;\n  background: rgba(255,255,255,.94); color: var(--lm-text2);\n  display: flex; align-items: center; overflow-x: auto;\n  white-space: nowrap; height: 52px; padding: 0 16px; margin: 0 0 24px;\n  box-shadow: 0 2px 10px rgba(60,50,30,.10); border-bottom: 2px solid var(--lm-gold);\n  backdrop-filter: blur(8px);\n}\n.lm-toc-bar::-webkit-scrollbar { height: 2px; }\n.lm-toc-bar::-webkit-scrollbar-thumb { background: var(--lm-gold); }\n.lm-toc-item {\n  display: inline-flex; align-items: center; height: 52px;\n  padding: 0 14px; color: var(--lm-text2); text-decoration: none;\n  font-size: 13px; font-weight: 500; letter-spacing: .3px;\n  border-bottom: 2px solid transparent; transition: all .25s; flex-shrink: 0;\n}\n.lm-toc-item:hover { color: var(--lm-text); background: rgba(200,155,60,.10); }\n.lm-toc-item.lm-active { color: var(--lm-gold2); border-bottom-color: var(--lm-gold); background: rgba(200,155,60,.12); }\n\n\/* ===== \u4e3b\u4f53 ===== *\/\n.lm-container { max-width: 1024px; margin: 24px auto 40px; padding: 0 16px; }\n\n\/* ===== \u7ae0\u8282\u5361\u7247 ===== *\/\n.lm-section {\n  background: var(--lm-bg2); border: 1px solid var(--lm-border); border-radius: 12px;\n  padding: 40px 36px; margin-bottom: 24px; box-shadow: 0 4px 18px rgba(60,50,30,.08); position: relative;\n  scroll-margin-top: 96px;\n}\n.lm-section-title {\n  font-size: 22px; font-weight: 700; color: var(--lm-gold2);\n  padding-bottom: 12px; margin-bottom: 24px;\n  border-bottom: 3px solid var(--lm-gold); display: flex; align-items: center; gap: 10px;\n}\n.lm-section-title .lm-num {\n  display: inline-flex; align-items: center; justify-content: center;\n  width: 34px; height: 34px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3));\n  color: var(--lm-on-gold); border-radius: 50%; font-size: 14px; font-weight: 800; flex-shrink: 0;\n}\n\n\/* ===== \u8868\u683c ===== *\/\n.lm-table { width: 100%; border-collapse: collapse; margin: 16px 0 20px; font-size: 14px; }\n.lm-table th { background: var(--lm-bg3); color: var(--lm-gold2); padding: 10px 12px; text-align: center; font-weight: 600; border: 1px solid var(--lm-border); }\n.lm-table td { padding: 10px 12px; border: 1px solid var(--lm-border); text-align: center; color: var(--lm-text); }\n.lm-table tr:nth-child(even) td { background: rgba(212,160,23,.04); }\n.lm-table tr:hover td { background: rgba(212,160,23,.10); }\n.lm-table .lm-row-hl td { background: rgba(212,160,23,.12) !important; font-weight: 700; color: var(--lm-gold2); }\n\n\/* ===== \u6807\u7b7e ===== *\/\n.lm-tag { display: inline-block; padding: 2px 10px; border-radius: 4px; font-size: 12px; font-weight: 600; }\n.lm-tag-blue { background: rgba(212,160,23,.18); color: var(--lm-gold2); }\n.lm-tag-green { background: rgba(111,174,133,.18); color: var(--lm-green); }\n.lm-tag-orange { background: rgba(217,154,78,.20); color: var(--lm-orange); }\n.lm-tag-red { background: rgba(192,57,43,.12); color: #c0392b; }\n\n\/* ===== \u5bf9\u6bd4\u6846 ===== *\/\n.lm-compare-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin: 20px 0; }\n.lm-compare-card { border-radius: 10px; padding: 24px 20px; border: 2px solid var(--lm-border); position: relative; background: var(--lm-bg2); }\n.lm-compare-card.lm-recommend { border-color: var(--lm-gold); background: rgba(212,160,23,.06); }\n.lm-compare-card .lm-badge { position: absolute; top: -12px; left: 20px; padding: 2px 14px; border-radius: 20px; font-size: 12px; font-weight: 700; color: var(--lm-bg); }\n.lm-badge-rec { background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); }\n.lm-badge-comp { background: #5a4d38; color: #fff; }\n.lm-compare-card h4 { font-size: 16px; margin-bottom: 12px; color: var(--lm-gold2); }\n.lm-compare-card ul { list-style: none; padding: 0; }\n.lm-compare-card li { padding: 6px 0; font-size: 14px; border-bottom: 1px solid var(--lm-border); color: var(--lm-text); }\n.lm-compare-card li:last-child { border-bottom: none; }\n.lm-compare-card li::before { content: \"> \"; color: var(--lm-gold); font-weight: 700; }\n\n\/* ===== \u9ad8\u4eae\u6846 ===== *\/\n.lm-highlight { background: rgba(212,160,23,.10); border-left: 4px solid var(--lm-gold); padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n.lm-highlight-blue { background: rgba(77,140,200,.10); border-left: 4px solid #4d8cc8; padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n.lm-highlight-green { background: rgba(111,174,133,.10); border-left: 4px solid var(--lm-green); padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n\n\/* ===== \u4fe1\u606f\u5361 ===== *\/\n.lm-info-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 12px; margin: 16px 0; }\n.lm-info-item { background: var(--lm-bg3); border: 1px solid var(--lm-border); border-radius: 8px; padding: 14px 16px; text-align: center; }\n.lm-info-item .lm-label { font-size: 12px; color: var(--lm-text2); margin-bottom: 4px; }\n.lm-info-item .lm-value { font-size: 18px; font-weight: 700; color: var(--lm-gold2); }\n\n\/* ===== \u6b65\u9aa4\u6d41 ===== *\/\n.lm-step-flow { display: flex; flex-wrap: wrap; gap: 8px; margin: 16px 0; }\n.lm-step-flow .lm-step { background: var(--lm-bg3); border: 1px solid var(--lm-border); padding: 8px 16px; border-radius: 20px; font-size: 13px; color: var(--lm-text2); }\n\n\/* ===== \u7cbe\u5de5\u516d\u6b65\u6cd5 \u8f6e\u64ad ===== *\/\n.lm-carousel { position: relative; margin: 18px 0 8px; border-radius: 12px; overflow: hidden; background: var(--lm-bg2); border: 1px solid var(--lm-border); }\n.lm-carousel-track { display: flex; transition: transform .55s cubic-bezier(.4,0,.2,1); }\n.lm-slide { min-width: 100%; }\n.lm-cs-head { display: flex; align-items: center; gap: 12px; padding: 16px 20px; background: linear-gradient(90deg, var(--lm-bg3), var(--lm-bg4)); color: var(--lm-gold2); border-bottom: 1px solid var(--lm-border); }\n.lm-cs-num { background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); font-weight: 800; font-size: 15px; width: 32px; height: 32px; border-radius: 50%; display: flex; align-items: center; justify-content: center; flex-shrink: 0; }\n.lm-cs-title { font-size: 17px; font-weight: 700; }\n.lm-cs-body { padding: 16px 20px 6px; font-size: 14px; line-height: 1.8; color: var(--lm-text); }\n.lm-cs-std { padding: 6px 20px 14px; font-size: 13px; color: var(--lm-gold2); }\n.lm-cs-std b { color: var(--lm-gold2); }\n.lm-cs-imgs { padding: 0 20px 18px; display: flex; gap: 14px; flex-wrap: wrap; align-items: flex-start; }\n.lm-cs-imgs img { width: 300px; height: 210px; object-fit: cover; border-radius: 8px; border: 1px solid var(--lm-border); display: block; }\n.lm-cs-imgs .lm-cap { font-size: 12px; color: var(--lm-text2); margin-top: 4px; text-align: center; }\n.lm-cs-imgs figure { margin: 0; }\n.lm-cs-imgs figure:only-child { flex: 1 1 100%; }\n.lm-cs-imgs figure:only-child img { width: 100%; height: auto; max-height: 480px; object-fit: contain; background: var(--lm-bg3); }\n.lm-car-arrow { position: absolute; top: 50%; transform: translateY(-50%); width: 42px; height: 42px; background: rgba(200,155,60,.88); border: none; border-radius: 50%; font-size: 24px; line-height: 1; color: var(--lm-on-gold); cursor: pointer; display: flex; align-items: center; justify-content: center; transition: all .25s; z-index: 3; box-shadow: 0 2px 8px rgba(0,0,0,.18); }\n.lm-car-arrow:hover { background: var(--lm-gold); }\n.lm-car-arrow.lm-prev { left: 12px; }\n.lm-car-arrow.lm-next { right: 12px; }\n.lm-car-dots { position: absolute; bottom: 12px; left: 0; right: 0; display: flex; gap: 8px; justify-content: center; z-index: 3; }\n.lm-car-dots .lm-dot { width: 9px; height: 9px; border-radius: 50%; background: rgba(154,116,20,.30); cursor: pointer; transition: all .25s; }\n.lm-car-dots .lm-dot.lm-active { background: var(--lm-gold); width: 22px; border-radius: 5px; }\n\n\/* ===== \u65b9\u6848\u8bbe\u8ba1\u00b7\u4ea7\u54c1\u5361\u7247 ===== *\/\n.lm-prod-showcase { display: flex; gap: 16px; flex-wrap: wrap; margin: 18px 0; }\n.lm-prod-card { flex: 0 0 auto; width: 320px; border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; background: var(--lm-bg2); box-shadow: 0 2px 10px rgba(60,50,30,.10); }\n.lm-prod-card img { width: 100%; height: 200px; object-fit: cover; display: block; }\n.lm-prod-card .lm-pc-body { padding: 12px 14px 14px; }\n.lm-prod-card .lm-pc-title { font-size: 14px; font-weight: 600; color: var(--lm-gold2); margin-bottom: 4px; }\n.lm-prod-card .lm-pc-desc { font-size: 12px; color: var(--lm-text2); margin-bottom: 10px; line-height: 1.6; }\n.lm-prod-card .lm-pc-link { display: inline-block; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); font-size: 13px; font-weight: 600; padding: 6px 16px; border-radius: 20px; text-decoration: none; }\n.lm-prod-card .lm-pc-link:hover { background: var(--lm-gold2); }\n\n\/* ===== Tabs\uff08\u7cfb\u7edf\u5bf9\u6bd4\uff09 ===== *\/\n.lm-tabs-nav { display: flex; gap: 0; margin: 18px 0 0; border-bottom: 2px solid var(--lm-border); flex-wrap: wrap; }\n.lm-tab-btn { background: var(--lm-bg3); color: var(--lm-text2); border: 1px solid var(--lm-border); border-bottom: none; padding: 10px 22px; font-size: 14px; font-weight: 600; cursor: pointer; transition: all .25s; border-radius: 8px 8px 0 0; margin-right: 4px; }\n.lm-tab-btn:hover { color: var(--lm-gold2); }\n.lm-tab-btn.lm-active { background: var(--lm-gold); color: var(--lm-on-gold); border-color: var(--lm-gold); }\n.lm-tab-panel { display: none; padding: 8px 0; }\n.lm-tab-panel.lm-active { display: block; animation: lmFade .3s; }\n@keyframes lmFade { from { opacity: 0; } to { opacity: 1; } }\n\n\/* ===== \u624b\u98ce\u7434\uff08\u8f85\u6750\u6e05\u5355\uff09 ===== *\/\n.lm-acc { margin: 16px 0; border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; }\n.lm-acc-item { border-bottom: 1px solid var(--lm-border); }\n.lm-acc-item:last-child { border-bottom: none; }\n.lm-acc-head { display: flex; align-items: center; justify-content: space-between; padding: 14px 18px; background: var(--lm-bg3); cursor: pointer; font-size: 15px; font-weight: 600; color: var(--lm-gold2); transition: background .2s; user-select: none; }\n.lm-acc-head:hover { background: var(--lm-bg4); }\n.lm-acc-head .lm-acc-ico { color: var(--lm-gold); font-size: 18px; transition: transform .3s; }\n.lm-acc-item.lm-open .lm-acc-head .lm-acc-ico { transform: rotate(45deg); }\n.lm-acc-body { max-height: 0; overflow: hidden; transition: max-height .4s ease; background: var(--lm-bg2); }\n.lm-acc-item.lm-open .lm-acc-body { max-height: 1200px; }\n.lm-acc-body-inner { padding: 4px 18px 18px; }\n\n\/* ===== \u56fe\u8868 ===== *\/\n.lm-chart-box { background: var(--lm-bg2); border: 1px solid var(--lm-border); border-radius: 10px; padding: 16px; margin: 20px 0; }\n.lm-chart-box .lm-chart-title { font-size: 15px; font-weight: 600; color: var(--lm-gold2); margin-bottom: 10px; }\n.lm-chart { width: 100%; height: 340px; }\n\n\/* ===== \u6848\u4f8b\u5185\u94fe ===== *\/\n.lm-case-link { color: var(--lm-gold2); font-weight: 600; text-decoration: none; border-bottom: 1px dashed var(--lm-gold); }\n.lm-case-link:hover { color: var(--lm-gold); border-bottom-color: var(--lm-gold2); }\n.lm-case-link::after { content: \" \u2197\"; font-size: 11px; color: var(--lm-gold); }\n\n\/* ===== \u4e09\u56fe\u5e76\u6392 ===== *\/\n.lm-img-row { display: flex; gap: 16px; margin: 20px 0; flex-wrap: wrap; }\n.lm-img-row .lm-img-card { flex: 1; min-width: 200px; border-radius: 10px; overflow: hidden; box-shadow: 0 2px 10px rgba(60,50,30,.10); background: var(--lm-bg2); text-align: center; border: 1px solid var(--lm-border); }\n.lm-img-row .lm-img-card img { width: 100%; height: auto; display: block; }\n.lm-img-row .lm-img-card .lm-img-label { padding: 8px 10px; font-size: 13px; color: var(--lm-gold2); background: var(--lm-bg3); border-top: 1px solid var(--lm-border); }\n\n\/* ===== \u5c01\u9762\uff08\u82f1\u96c4\u680f\uff09 ===== *\/\n.lm-cover {\n  text-align: center; padding: 90px 36px 80px; position: relative; overflow: hidden;\n  color: #fff;\n  background-image:\n    linear-gradient(135deg, rgba(20,16,8,.80) 0%, rgba(40,30,15,.58) 50%, rgba(20,16,8,.82) 100%),\n    url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-yxl-zrqxyxl.jpg');\n  background-size: cover; background-position: center center; background-repeat: no-repeat;\n  min-height: 480px; display: flex; flex-direction: column; justify-content: center;\n  border: 1px solid var(--lm-border); border-radius: 12px; margin-bottom: 24px; box-shadow: 0 4px 18px rgba(0,0,0,.35);\n  border-bottom: 3px solid var(--lm-gold);\n}\n.lm-cover::before {\n  content: \"\"; position: absolute; top: 0; left: 0; right: 0; height: 6px; z-index: 2;\n  background: linear-gradient(90deg, var(--lm-gold), var(--lm-gold2), var(--lm-gold));\n}\n.lm-cover::after {\n  content: \"\"; position: absolute; bottom: 0; left: 0; right: 0; height: 80px;\n  background: linear-gradient(180deg, transparent, rgba(20,16,8,.6)); pointer-events: none;\n}\n.lm-cover > * { position: relative; z-index: 1; }\n.lm-cover h1 { font-size: 38px; color: #fff; margin-bottom: 12px; text-shadow: 0 2px 12px rgba(0,0,0,.7); letter-spacing: 1px; }\n.lm-cover .lm-sub { font-size: 20px; color: #e8dcc0; margin-bottom: 24px; text-shadow: 0 1px 6px rgba(0,0,0,.6); font-weight: 300; }\n.lm-cover .lm-meta { display: flex; justify-content: center; gap: 28px; flex-wrap: wrap; font-size: 14px; color: #d8c8a8; margin-top: 20px; }\n.lm-cover .lm-meta span { background: rgba(212,160,23,.14); padding: 6px 14px; border-radius: 20px; backdrop-filter: blur(4px); border: 1px solid rgba(212,160,23,.35); }\n.lm-cover .lm-meta .lm-brand-tag { background: rgba(212,160,23,.22); color: var(--lm-gold2); font-weight: 600; border: 1px solid rgba(212,160,23,.5); }\n\n\/* ===== \u95e8\u5e97\/\u8054\u7cfb\u4fe1\u606f\u9875\u811a ===== *\/\n.lm-contact-footer { padding: 0; }\n.lm-cf-header { text-align: center; padding: 32px 24px 20px; border-bottom: 1px solid var(--lm-border); }\n.lm-cf-header .lm-cf-title { font-size: 22px; font-weight: 700; color: var(--lm-gold2); display: flex; align-items: center; justify-content: center; gap: 8px; }\n.lm-cf-header .lm-cf-title .lm-phone-icon { color: var(--lm-gold); font-size: 24px; }\n.lm-cf-header .lm-cf-sub { font-size: 14px; color: var(--lm-text2); margin-top: 8px; }\n\n.lm-cf-contacts { display: grid; grid-template-columns: repeat(4, 1fr); gap: 12px; padding: 20px 24px; }\n.lm-cf-contact { display: flex; align-items: center; gap: 10px; padding: 12px 16px; border: 1px solid var(--lm-border); border-radius: 8px; background: var(--lm-bg3); transition: all .25s; text-decoration: none; }\n.lm-cf-contact:hover { border-color: var(--lm-gold); background: rgba(212,160,23,.08); }\n.lm-cf-contact .lm-ic { width: 32px; height: 32px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); border-radius: 8px; display: flex; align-items: center; justify-content: center; font-size: 16px; flex-shrink: 0; }\n.lm-cf-contact .lm-info { display: flex; flex-direction: column; }\n.lm-cf-contact .lm-label { font-size: 12px; color: var(--lm-text2); }\n.lm-cf-contact .lm-phone { font-size: 15px; font-weight: 700; color: var(--lm-gold2); }\n\n.lm-cf-services { display: grid; grid-template-columns: repeat(4, 1fr); gap: 8px; padding: 0 24px 20px; }\n.lm-cf-service { display: flex; align-items: center; gap: 6px; padding: 8px 12px; background: var(--lm-bg3); border-radius: 6px; font-size: 13px; color: var(--lm-text); }\n.lm-cf-service .lm-ck { color: var(--lm-green); font-weight: 700; font-size: 14px; }\n\n.lm-cf-stores { display: grid; grid-template-columns: 1fr 1fr; gap: 16px; padding: 0 24px 20px; }\n.lm-cf-store { border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; background: var(--lm-bg2); }\n.lm-cf-store .lm-store-label { padding: 8px 14px; background: var(--lm-bg3); font-size: 14px; font-weight: 600; color: var(--lm-gold2); display: flex; align-items: center; gap: 6px; border-bottom: 1px solid var(--lm-border); }\n.lm-cf-store .lm-store-label .lm-pin { color: var(--lm-gold); }\n.lm-cf-store img { width: 100%; height: 200px; object-fit: cover; display: block; }\n.lm-cf-store .lm-store-addr { padding: 10px 14px; font-size: 13px; color: var(--lm-text2); display: flex; gap: 6px; align-items: flex-start; }\n.lm-cf-store .lm-store-addr .lm-pin { color: var(--lm-gold); flex-shrink: 0; }\n\n.lm-cf-service-area { text-align: center; padding: 16px 24px; font-size: 13px; color: var(--lm-text); border-top: 1px solid var(--lm-border); border-bottom: 1px solid var(--lm-border); background: var(--lm-bg3); }\n.lm-cf-service-area .lm-label { font-weight: 600; color: var(--lm-gold2); margin-right: 8px; }\n\n.lm-cf-cta { text-align: center; padding: 24px; }\n.lm-cf-cta .lm-btn { display: inline-flex; align-items: center; gap: 6px; padding: 12px 36px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); border-radius: 30px; font-size: 15px; font-weight: 700; text-decoration: none; box-shadow: 0 4px 14px rgba(200,155,60,.30); transition: all .25s; }\n.lm-cf-cta .lm-btn:hover { background: var(--lm-gold2); transform: translateY(-1px); }\n\n.lm-cf-footer-note { text-align: center; padding: 12px 24px 24px; font-size: 12px; color: var(--lm-text2); }\n\n\/* \u5916\u94fe\u7ea2\uff08GEO\u6280\u672f\u89c4\u8303\uff09\uff1a\u5916\u90e8\u7ad9\u70b9\u94fe\u63a5\u7ea2\u8272\u52a0\u4e0b\u5212\u7ebf *\/\na[href*=\"\/\/\"]:not([href*=\"longmai-nt.com\"]) { color: var(--lm-red); text-decoration: underline; }\n\n@media (max-width: 768px) {\n  .lm-cf-contacts, .lm-cf-services { grid-template-columns: 1fr 1fr; }\n  .lm-cf-stores { grid-template-columns: 1fr; }\n  .lm-cf-store img { height: 160px; }\n  .lm-compare-grid { grid-template-columns: 1fr; }\n  .lm-container { margin-top: 60px; padding: 0 10px; }\n  .lm-section { padding: 24px 16px; }\n  .lm-cover h1 { font-size: 24px; }\n  .lm-toc-item { padding: 0 10px; font-size: 12px; }\n  .lm-table { font-size: 12px; }\n  .lm-table th, .lm-table td { padding: 6px 8px; }\n  .lm-info-grid { grid-template-columns: 1fr 1fr; }\n  .lm-cs-imgs img { width: 200px; height: 140px; }\n  .lm-cs-imgs figure:only-child img { width: 100%; height: auto; max-height: 320px; object-fit: contain; }\n}\n\n\/* ===== \u65b0\u589e\uff1a\u7ffb\u8f6c\u5361 + sticky\u76ee\u5f55\uff08\u5ba1\u8ba1\u4fee\u590d 7224\uff09 ===== *\/\n.lm-flip-card { min-height: 400px; margin: 22px 0; perspective: 1400px; }\n.lm-flip-inner { display: grid; min-height: 400px; transition: transform .6s ease; transform-style: preserve-3d; }\n.lm-flip-front, .lm-flip-back {\n  grid-area: 1 \/ 1; box-sizing: border-box; min-height: 400px; border-radius: 12px; padding: 20px;\n  backface-visibility: hidden; -webkit-backface-visibility: hidden;\n}\n.lm-flip-front {\n  background: linear-gradient(135deg, #1c1810 0%, #2a2113 55%, #1c1810 100%);\n  color: #e8dcc0; border: 1px solid var(--lm-gold);\n}\n.lm-flip-back {\n  background: var(--lm-bg2); color: var(--lm-text);\n  border: 1px solid var(--lm-border); transform: rotateY(180deg); overflow: auto;\n}\n.lm-flip-card:hover .lm-flip-inner,\n.lm-flip-card.is-flipped .lm-flip-inner { transform: rotateY(180deg); }\n.lm-flip-title { font-size: 16px; font-weight: 700; color: var(--lm-gold2); margin-bottom: 10px; }\n.lm-flip-front .lm-flip-title { color: #e8dcc0; }\n.lm-flip-cap { font-size: 12px; color: #b9a374; margin-top: 10px; text-align: center; }\n.lm-flip-back .lm-flip-tip { font-size: 12px; color: var(--lm-gold2); margin: 0 0 10px; text-align: center; font-weight: 600; }\n.lm-flip-card .lm-chart-fallback { display: none; font-size: 13px; color: #b9a374; text-align: center; padding: 30px 10px; }\n#chart-six-7224, #chart-20y-7224 { width: 100%; height: 340px; }\n.lm-flip-card-20y .lm-flip-back { overflow: auto; }\n@media (max-width: 768px) {\n  .lm-toc-bar { top: 0; margin-bottom: 16px; }\n  .lm-flip-front, .lm-flip-back { padding: 14px; }\n  #chart-six-7224, #chart-20y-7224 { height: 300px; }\n}\n<\/style>\n\n<!-- ====================================================================== -->\n<!-- \u2605\u2605\u2605\u2605\u2605\u2605\u2605\u2605\u2605\u2605  \u65b9\u6848\u5168\u4e66 \u00b7 \u53d8\u91cf\u6a21\u677f\u4f7f\u7528\u8bf4\u660e  \u2605\u2605\u2605\u2605\u2605\u2605\u2605\u2605\u2605\u2605 -->\n<!-- \u672c\u6a21\u677f\u6309\u300c\u5b9a\u91cf\u53d8\u91cf\u539f\u7406\u300d\u8bbe\u8ba1\uff1a                                              -->\n<!--   \u56fa\u5b9a\u6846\u67b6\uff08\u6837\u5f0f\/\u6280\u672f\u539f\u7406\/\u8bdd\u672f\/\u65bd\u5de5\u6d41\u7a0b\/\u56fe\u8868\u903b\u8f91\uff09\u5df2\u5199\u6b7b\uff0c\u8bf7\u52ff\u6539\u52a8\uff1b       -->\n<!--   \u968f\u6bcf\u4e2a\u9879\u76ee\u53d8\u5316\u7684\u6570\u636e\uff0c\u5168\u90e8\u96c6\u4e2d\u5728\u4e0b\u65b9 <script> \u7684 PROJECT \u5bf9\u8c61\u91cc\u3002        -->\n<!-- \u4ee5\u540e\u505a\u65b0\u65b9\u6848\uff1a\u53ea\u9700\u4fee\u6539 PROJECT \u91cc\u7684\u503c\uff08\u5ba2\u6237\u540d\/\u9762\u79ef\/\u578b\u53f7\/\u4ef7\u683c\/\u53c2\u6570\/\u56fe\u7247\uff09\uff0c -->\n<!--   \u4fdd\u5b58\u540e\u7528\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u6587\u4ef6\uff0c\u5168\u6587\u81ea\u52a8\u5957\u7528\uff0c\u65e0\u9700\u6539\u52a8\u4efb\u4f55 HTML \u7ed3\u6784\u3002          -->\n<!-- \u89c4\u5219\uff1a\u4ef7\u683c\/\u6298\u6263\u4e00\u5f8b\u5f15\u6e90\u6307\u4ee402(page_id=662)\uff1b\u6c14\u4ef7\/\u7535\u4ef7\/\u7ef4\u4fdd\u7b49\u6613\u53d8\u503c30\u5929\u590d\u6838\u3002 -->\n<!-- ====================================================================== -->\n\n<script id=\"lm-project-config\">\n\/* ============================================================\n *  \u2605 \u552f\u4e00\u9700\u8981\u7f16\u8f91\u7684\u533a\u57df\uff1aPROJECT \u914d\u7f6e\u5bf9\u8c61 \u2605\n *  \u952e\u540d\uff08\u4e2d\u6587\uff09\u5bf9\u5e94\u6b63\u6587\u4e2d\u7684\u53cc\u82b1\u62ec\u53f7\u5360\u4f4d\u7b26\uff08\u6e32\u67d3\u65f6\u81ea\u52a8\u66ff\u6362\u4e3a\u540c\u540d\u914d\u7f6e\u503c\uff09\u3002\n *  \u6570\u7ec4\u7c7b\u53d8\u91cf\uff08\u914d\u7f6e\u8868\/\u62a5\u4ef7\u8868\/\u6848\u4f8b\u8868\/20\u5e74\u8868\uff09\u884c\u6570\u53ef\u53d8\uff0c\n *  \u76f4\u63a5\u589e\u5220\u6570\u7ec4\u5143\u7d20\u5373\u53ef\uff1b\u9ad8\u4eae\u5c0f\u8ba1\u884c\u7528 \"__HL__\" \u4f5c\u4e3a\u8be5\u884c\u9996\u4e2a\u5143\u7d20\u3002\n * ============================================================ *\/\nconst PROJECT = {\n  \/* ---------- 1. \u9879\u76ee\u57fa\u672c\u4fe1\u606f ---------- *\/\n  \"\u5ba2\u6237\u59d3\u540d\": \"\u718a\u603b\",\n  \"\u9879\u76ee\u7c7b\u578b\": \"\u522b\u5885\",                 \/\/ \u7528\u4e8e\u5c01\u9762\u6807\u9898\uff0c\u5982 \u522b\u5885\/\u5927\u5e73\u5c42\/\u4e09\u623f\n  \"\u7269\u4e1a\u7c7b\u578b\": \"\u522b\u5885\",                 \/\/ \u5c01\u9762\u5143\u4fe1\u606f\u00b7\u7269\u4e1a\u7c7b\u578b\n  \"\u697c\u5c42\u63cf\u8ff0\": \"\u8d1f2F-4F \u51716\u5c42\",         \/\/ \u5c01\u9762\u5143\u4fe1\u606f\u00b7\u5efa\u7b51\u5c42\u6570\n  \"\u91c7\u6696\u9762\u79ef\": \"250 \u33a1\",\n  \"\u5e38\u4f4f\u4eba\u53e3\": \"5-6\u4eba\",\n  \"\u65e5\u671f\": \"2026\u5e747\u670819\u65e5\",\n  \"\u5730\u4e0b\u5ba4\u9762\u79ef\": \"\u8d1f1F+\u8d1f2F\",\n  \"\u7a7a\u8c03\u9700\u6c42\": \"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\",\n  \"\u9879\u76ee\u5730\u5740\": \"\u718a\u603b\u522b\u5885\",\n\n  \/* ---------- 2. S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807 ---------- *\/\n  \"\u6838\u5fc3\u8bc9\u6c42\": \"\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355\u3002\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\u539f\u8ba1\u5212\u505a\u67dc\u6302\u673a+\u4e0d\u505a\u5730\u6696\u3002\",\n  \"\u5730\u4e0b\u5ba4\u7814\u5224\": \"\u5173\u4e8e\u539f\u5b9a\u67dc\u6302\u673a\u65b9\u6848\u7684\u7814\u5224\uff1a<br>\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\u82e5\u7528\u67dc\u6302\u673a\uff0c\u5b58\u5728\u4ee5\u4e0b\u95ee\u9898\uff1a<br>1. \u5916\u673a\u5b89\u88c5\u56f0\u96be\u2014\u2014\u8d1f\u4e00\u4e8c\u697c\u5916\u7acb\u9762\u65e0\u5408\u9002\u5916\u673a\u4f4d\uff0c\u7ba1\u8def\u9700\u7a7f\u8fc7\u697c\u5c42\uff0c\u65bd\u5de5\u590d\u6742\uff1b<br>2. \u7ba1\u8def\u8d70\u7ebf\u56f0\u96be\u2014\u2014\u4ece\u5730\u4e0b\u5ba4\u5230\u5ba4\u5916\u9700\u957f\u8ddd\u79bb\u94dc\u7ba1\uff0c\u5f71\u54cd\u7f8e\u89c2\u548c\u6548\u7387\uff1b<br>3. \u9664\u6e7f\u80fd\u529b\u4e0d\u8db3\u2014\u2014\u666e\u901a\u67dc\u6302\u673a\u9664\u6e7f\u4f9d\u8d56\u5236\u51b7\uff0c\u6885\u96e8\u5b63\u65e0\u6cd5\u72ec\u7acb\u9664\u6e7f\uff1b<br>4. \u65b0\u98ce\u7f3a\u5931\u2014\u2014\u5730\u4e0b\u5ba4\u5bc6\u95ed\uff0c\u65e0\u65b0\u98ce\u7cfb\u7edf\u7a7a\u6c14\u8d28\u91cf\u5dee\u3002<br><br><strong>\u5efa\u8bae\u65b9\u6848\uff1a<\/strong>\u91c7\u7528\u8212\u4eab\u4e00\u62d6\u56db\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\uff0c\u5185\u673a\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\uff08\u6700\u4f4e10\u2103\u53ef\u9664\u6e7f\uff09\uff0c\u642d\u914d\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce\u89e3\u51b3\u901a\u98ce\u6362\u6c14\u95ee\u9898\u3002\u6027\u4ef7\u6bd4\u9ad8\uff0c\u6548\u679c\u597d\uff0c\u514d\u53bb\u5916\u673a\u4f4d\u548c\u7ba1\u8def\u7684\u70e6\u607c\u3002\",\n  \/\/ \u8bca\u65ad\u5206\u6790\u8868\uff1a\u6bcf\u884c [\u75db\u70b9\/\u95ee\u9898, \u8868\u73b0, \u5e94\u5bf9\u7b56\u7565]\n  \"\u8bca\u65ad\u8868\": [\n    [\"\u5730\u4e0b\u5ba4\u67dc\u6302\u673a\u65b9\u6848\u4e0d\u5408\u7406\",\"\u8d1f1F\u8d1f2F\u5916\u673a\u4f4d\u96be\u627e\uff0c\u7ba1\u8def\u96be\u8d70\u5730\u9762\",\"\u6539\u7528\u8212\u4eab\u4e00\u62d6\u56db + \u4f4e\u6e29\u9664\u6e7f\u5305 + \u4e91\u51c0\u65b0\u98ce\"],\n    [\"\u5730\u4e0b\u5ba4\u9664\u6e7f\u9700\u6c42\",\"\u6210\u90fd\u6f6e\u6e7f\uff0c\u6885\u96e8\u5b63\u5730\u4e0b\u5ba4\u6613\u53d1\u9709\",\"\u8212\u4eab\u5185\u673a\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\uff0c\u6700\u4f4e10\u2103\u53ef\u9664\u6e7f\"],\n    [\"\u65b0\u98ce\u6362\u6c14\u9700\u6c42\",\"\u5730\u4e0b\u5ba4\u65e0\u81ea\u7136\u901a\u98ce\uff0c\u7a7a\u6c14\u4e0d\u6d41\u901a\",\"\u914d\u7f6e\u65e5\u7acb\u4e91\u51c0KPI-3521Q3A\/F\u65b0\u98ce\u7cfb\u7edf\"],\n    [\"1F-4F\u51b7\u6696\u9700\u6c42\",\"\u9700\u8981\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\uff0c\u8212\u9002\u5065\u5eb7\",\"\u5c0a\u777f\u5168\u6548280 + \u6c34\u6a21\u5757280 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\"],\n    [\"\u9664\u6e7f\u4e0e\u7a7a\u6c14\u54c1\u8d28\",\"\u56db\u5ddd\u5730\u533a\u6e7f\u5ea6\u5927\uff0c\u6885\u96e8\u5b63\u4f53\u611f\u5dee\",\"\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\u6807\u914d\u4e0d\u964d\u6e29\u9664\u6e7f + PE\u51c0\u5316\"],\n    [\"\u7cfb\u7edf\u7a33\u5b9a\u6027\u4e0e\u7ef4\u62a4\",\"\u8981\u6c42\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355\",\"\u5c0a\u777f\u5168\u6548\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\uff0c\u6545\u969c\u5c11\"],\n    [\"\u8282\u80fd\u9700\u6c42\",\"\u957f\u671f\u4f7f\u7528\u5e0c\u671b\u8fd0\u884c\u8d39\u7528\u4f4e\",\"\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u5730\u6696\uff0cCOP\u22653.0\uff0c\u6bd4\u71c3\u6c14\u7089\u770130%+\"]\n  ],\n\n  \/* ---------- 3. S2 \u65b9\u6848\u8bca\u65ad ---------- *\/\n  \"\u65b9\u6848A\u540d\": \"\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u5929\u6c1f\u5730\u6c34\uff09\",   \/\/ \u63a8\u8350\u65b9\u6848\uff08\u901a\u5e38\u4e3a\u672c\u9879\u76ee\u7684\u65b9\u6848\uff09\n  \"\u65b9\u6848B\u540d\": \"\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09\",             \/\/ \u5bf9\u6bd4\u65b9\u6848\n  \"\u65b9\u6848A\u7b80\u79f0\": \"\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09\",\n  \"\u65b9\u6848B\u7b80\u79f0\": \"\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09\",\n  \/\/ S2 \u4e09\u6bb5 Tab \u8868\uff1a\u6bcf\u884c [\u7ef4\u5ea6, A\u63cf\u8ff0, B\u63cf\u8ff0, \u7ed3\u8bba]\uff08\u7ed3\u8bba\u53ef\u7528 {\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}\uff09\n  \"S2\u4f53\u9a8c\u8868\": [\n    [\"\u5236\u51b7\u4f53\u9a8c\",\"\u5236\u51b7\u5feb\uff0c\u51fa\u98ce7-12\u2103\uff0c\u9664\u6e7f\u6781\u5f3a\u3002\u4e09\u7ba1\u5236\u5185\u673a\u6807\u914d\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u6885\u96e8\u5b63\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29\",\"\u51fa\u98ce\u67d4\u548c15-20\u2103\uff0c\u4f46\u9664\u6e7f\u5f31\uff0c\u9700\u4f9d\u8d56\u5236\u51b7\u9664\u6e7f\uff0c\u6885\u96e8\u5b63\u4f53\u611f\u504f\u95f7\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}],\n    [\"\u5236\u70ed\u4f53\u9a8c\",\"\u5730\u6696\u7531\u6c34\u6a21\u5757\u4f9b\u70ed\uff0c\u5ba4\u6e29\u5747\u5300\u3002\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a-25\u2103\u7a33\u5b9a\u8fd0\u884c\",\"\u5730\u6696\u5747\u5300\u4f9b\u70ed\uff0c\u6c34\u7cfb\u7edf\u67d4\u548c\u4e0d\u5e72\u71e5\uff0c\u51fa\u6c34\u6e29\u5ea6\u53ef\u8c03\u8303\u56f4\u66f4\u5bbd\",\"\u57fa\u672c\u6301\u5e73\"],\n    [\"\u9664\u6e7f\u80fd\u529b\",\"\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u9664\u6e7f\u91cf175L\/\u5929\uff0c\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\/\u5730\u4e0b\u5ba4\u6781\u53cb\u597d\",\"\u9664\u6e7f\u5f31\uff0c\u9700\u9760\u5236\u51b7\u9664\u6e7f\uff0c\u72ec\u7acb\u9664\u6e7f\u9700\u9009\u914d\uff08\u989d\u5916\u8d39\u7528\uff09\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}],\n    [\"\u7a7a\u6c14\u51c0\u5316\",\"\u6807\u914dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff0cPM2.5\u53bb\u9664\u738799%\uff1b\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a\u81ea\u5e26\u51c0\u5316\",\"\u51c0\u5316\u80fd\u529b\u8f83\u5f31\uff0c\u540c\u7b49\u914d\u7f6e\u9700\u989d\u5916\u9009\u914d\u51c0\u5316\u914d\u4ef6\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}]\n  ],\n  \"S2\u6280\u672f\u8868\": [\n    [\"\u7cfb\u7edf\u7c7b\u578b\",{\"html\":\"<span class='lm-tag lm-tag-blue'>\u5929\u6c1f\u5730\u6c34<\/span><br>\u7a7a\u8c03\u4fa7\u6c1f\u76f4\u51b7\uff08\u4e00\u6b21\u6362\u70ed\uff09\uff0c\u5730\u6696\u4fa7\u70ed\u6c34\"},{\"html\":\"<span class='lm-tag lm-tag-orange'>\u5929\u6c34\u5730\u6c34<\/span><br>\u7a7a\u8c03\u4e0e\u5730\u6696\u5747\u4e3a\u6c34\u7cfb\u7edf\uff08\u4e8c\u6b21\u6362\u70ed\uff09\"},\"\u2013\"],\n    [\"\u5b89\u88c5\u590d\u6742\u5ea6\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u6807\u51c6\u5316\u5b89\u88c5<\/span><br>\u7a7a\u8c03\u4fa7\u94dc\u7ba1\uff08\u6807\u51c6\u5316\u5de5\u827a\uff09\uff0c\u5730\u6696\u4fa7\u63a5\u7ba1\u7b80\u5355\"},{\"html\":\"<span class='lm-tag lm-tag-red'>\u8981\u6c42\u6781\u9ad8<\/span><br>\u9700\u6c34\u529b\u5e73\u8861\u8bbe\u8ba1\uff0c\u4e0d\u5f53\u6613\u6f0f\u6c34\/\u7ed3\u9732\/\u6548\u679c\u5dee\"},{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}],\n    [\"\u8fde\u63a5\u7387\u9650\u5236\",\"\u6c1f\u7cfb\u7edf\u2264150%\uff0c\u672c\u6848121%\u6b63\u5e38\u8303\u56f4\",\"\u53ef\u8d85200%\uff0c\u5927\u6237\u578b\u81ea\u7531\u5ea6\u66f4\u9ad8\",\"\u6c34\u5885\u9002\u7565\u4f18\"],\n    [\"\u521d\u6295\u8d44\",\"\u542b\u7a7a\u8c03+\u5730\u6696\uff0c\u8bbe\u5907\u6210\u719f\uff0c\u4ef7\u683c\u900f\u660e\",\"\u8bbe\u5907\u6210\u672c\u63a5\u8fd1\uff0c\u4f46\u5b89\u88c5\u8c03\u8bd5\u8d39\u7528\u66f4\u9ad8\",\"\u5c0a\u777f\u7565\u4f18\"]\n  ],\n  \"S2\u8fd0\u7ef4\u8868\": [\n    [\"\u81ea\u6e05\u6d01\",\"\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff0c\u51cf\u5c11\u4eba\u5de5\u6e05\u6d17\u9891\u7387\",\"\u6c34\u7cfb\u7edf\u65e0\u81ea\u6e05\u6d01\uff0c\u9700\u5b9a\u671f\u4eba\u5de5\u6e05\u6d17\u8fc7\u6ee4\u5668\/\u6362\u70ed\u5668\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}],\n    [\"\u7cfb\u7edf\u7a33\u5b9a\u6027\",\"\u6c1f\u7cfb\u7edf\u6210\u719f\u7a33\u5b9a\uff0c\u94dc\u7ba1\u5bc6\u5c01\u6027\u597d\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669\",\"\u5168\u6c34\u7cfb\u7edf\u63a5\u5934\u591a\uff0c\u957f\u671f\u5b58\u5728\u6f0f\u6c34\u98ce\u9669\uff0c\u8c03\u6559\u96be\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}],\n    [\"\u7ef4\u62a4\u7ef4\u4fee\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u7ef4\u62a4\u7b80\u5355<\/span><br>\u8fd0\u884c\u7a33\u5b9a\uff0c\u81ea\u6e05\u6d01\u51cf\u5c11\u6e05\u6d17\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\"},{\"html\":\"<span class='lm-tag lm-tag-orange'>\u7ef4\u62a4\u9700\u6c42\u9ad8<\/span><br>\u9700\u5b9a\u671f\u6e05\u6d17Y\u578b\u8fc7\u6ee4\u5668\u3001\u6392\u6c14\u9600\u3001\u8865\u6c34\u9600\uff0c\u6613\u7ed3\u57a2\"},{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}],\n    [\"20\u5e74\u8fd0\u7ef4\u603b\u6295\u5165\",\"\u6c1f\u673a\u7a33\u5b9a\u5c11\u6545\u969c\uff0c\u5e74\u7ef4\u4fdd\u4f4e\uff0c\u81ea\u6e05\u6d01\u7701\u6e05\u6d17\u5f00\u652f\",\"\u9700\u5b9a\u671f\u6362\u8fc7\u6ee4\u5668\u3001\u6d17\u7ba1\u8def\uff0c\u7ef4\u4fdd\u9ad8\uff0c\u6f5c\u5728\u7ef4\u4fee\u98ce\u9669\u5927\",{\"html\":\"<span class='lm-tag lm-tag-green'>\u5c0a\u777f\u4f18<\/span>\"}]\n  ],\n  \"\u7efc\u5408\u7ed3\u8bba\": \"\u9488\u5bf9{{\u5ba2\u6237\u59d3\u540d}}\u201c\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355\u201d\u7684\u6838\u5fc3\u8bc9\u6c42\uff0c<strong>\u63a8\u8350{{\u65b9\u6848A\u540d}}\u65b9\u6848<\/strong>\uff1a<br>1. <strong>\u529f\u80fd\u4f53\u9a8c\u4f73<\/strong>\u2014\u2014\u4e09\u7ba1\u5236\u5185\u673a\u72ec\u7acb\u4e0d\u964d\u6e29\u9664\u6e7f\uff08\u6210\u90fd\u6885\u96e8\u5b63\u521a\u9700\uff09+ PE\u51c0\u5316\u6807\u914d+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff1b<br>2. <strong>\u7cfb\u7edf\u7a33\u5b9a\u53ef\u9760<\/strong>\u2014\u2014\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669\uff1b<br>3. <strong>\u7ef4\u62a4\u7b80\u5355<\/strong>\u2014\u2014\u81ea\u6e05\u6d01\u51cf\u5c11\u4eba\u5de5\u6e05\u6d17\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\uff1b<br>4. <strong>\u9664\u6e7f\u80fd\u529b\u5f3a<\/strong>\u2014\u2014\u5730\u4e0b\u5ba4\u9632\u6f6e\u3001\u6885\u96e8\u5b63\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u5bf9\u56db\u5ddd\u6c14\u5019\u7279\u522b\u53cb\u597d\u3002\",\n  \/\/ \u516d\u7ef4\u5ea6\u5bf9\u6bd4\u8868\uff08\u80cc\u9762\uff09\uff1a\u6bcf\u884c [\u7ef4\u5ea6, A\u503c, B\u503c, \u7ed3\u8bba]\uff08\u7ed3\u8bba\u53ef\u542bHTML\uff09\n  \"\u516d\u7ef4\u8868\": [\n    [\"\u521d\u6295\u8d44\",\"\u00a5140,201\uff08\u7cfb\u7edf\u4e8c\u00b7\u5f15\u6e90\u6307\u4ee402=page_id=662\uff09\",\"\u5f85\u786e\u8ba4\u00b7\u4ee5\u52d8\u6d4b\u5b9e\u6d4b\u4e3a\u51c6\",\"\u5c0a\u777f\u7565\u4f18<br><span style='font-size:12px;color:var(--lm-text2)'>S2\uff1a\u8bbe\u5907\u6210\u672c\u63a5\u8fd1\uff0c\u6c34\u5885\u9002\u5b89\u88c5\u8c03\u8bd5\u8d39\u66f4\u9ad8<\/span>\"],\n    [\"\u8fd0\u884c\u8d39\uff08\u5e74\uff09\",\"\u2248\u00a53,600\uff08\u4f30\u7b97\u00b7\u6210\u90fd\u7535\u4ef70.52\u5143\/kWh\u00b7\u4ee5\u5b9e\u9645\u4e3a\u51c6\uff09\",\"\u2248\u00a54,000\uff08\u4f30\u7b97\u00b7\u5f85\u786e\u8ba4\uff09\",\"\u5c0a\u777f\u7701\u7ea610%<br><span style='font-size:12px;color:var(--lm-text2)'>\u7a7a\u6c14\u80fdCOP\u22653.0<\/span>\"],\n    [\"\u8212\u9002\u5ea6\",\"\u4f18\uff1a\u4e09\u7ba1\u5236\u4e0d\u964d\u6e29\u9664\u6e7f + PE\u51c0\u5316\u6807\u914d\",\"\u4e2d\uff1a\u51fa\u98ce\u67d4(15-20\u2103)\u4f46\u9664\u6e7f\u5f31\u3001\u51c0\u5316\u9700\u9009\u914d\",\"\u5c0a\u777f\u4f18\"],\n    [\"\u7a33\u5b9a\u6027\",\"\u4f18\uff1a\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u3001\u65e0\u6f0f\u6c34\u98ce\u9669\",\"\u4e2d\uff1a\u5168\u6c34\u7cfb\u7edf\u63a5\u5934\u591a\u3001\u957f\u671f\u6f0f\u6c34\u98ce\u9669\",\"\u5c0a\u777f\u4f18\"],\n    [\"\u7ef4\u62a4\u8d39\uff08\u5e74\uff09\",\"\u2248\u00a51,000\uff08800-1200\u00b7\u767d\u76ae\u4e66\/\u884c\u4e1a\u60ef\u4f8b\uff09\",\"\u2248\u00a51,200\uff08\u4f30\u7b97\u00b7\u5f85\u786e\u8ba4\u00b7\u9700\u5b9a\u671f\u6d17\u7ba1\u8def\/\u6362\u8fc7\u6ee4\u5668\uff09\",\"\u5c0a\u777f\u4f18\"],\n    [\"\u5bff\u547d\",\"\u4e3b\u673a\u6807\u79f015-20\u5e74\uff08\u53d618\u5e74\u00b7\u4ea7\u54c1\u6807\u79f0+\u767d\u76ae\u4e66\uff09\",\"15-20\u5e74\uff08\u4f30\u7b97\uff09\",\"\u57fa\u672c\u6301\u5e73\"]\n  ],\n  \/\/ \u516d\u7ef4\u96f7\u8fbe\u56fe\u5f52\u4e00\u5316\u5f97\u5206\uff080-100\uff0c\u8d8a\u5927\u8d8a\u4f18\uff1b\u6210\u672c\u7c7b\u5df2\u53cd\u5411\uff09\uff1a\u987a\u5e8f=\u521d\u6295\u8d44\/\u8fd0\u884c\u8d39\/\u8212\u9002\u5ea6\/\u7a33\u5b9a\u6027\/\u7ef4\u62a4\u8d39\/\u5bff\u547d\n  \"\u516d\u7ef4\u96f7\u8fbe\": { \"A\": [78,85,92,90,82,80], \"B\": [70,76,74,62,60,78] },\n\n  \/* ---------- 4. S3 \u7cfb\u7edf\u8bbe\u8ba1 ---------- *\/\n  \/\/ \u7cfb\u7edf\u67b6\u6784\u603b\u89c8\u5361\u7247\uff1a\u6bcf\u4e2a {badge, title, scope, items:[...]}\n  \"\u7cfb\u7edf\u5361\": [\n    { \"badge\":\"\u7cfb\u7edf\u4e00\", \"title\":\"\u8212\u4eab\u4e00\u62d6\u56db + \u5168\u70ed\u4ea4\u6362\u65b0\u98ce\", \"scope\":\"\u8d1f\u4e00\u697c \u00b7 \u8d1f\u4e8c\u697c\",\n      \"items\":[\"\u8212\u4eab125\u5916\u673a\uff08RAS-125HRNAQ\uff09\",\"\u8212\u4eab\u5185\u673a\u00d74\u53f0\uff08\u5747\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\uff09\",\"\u4e91\u51c0KPI-3521Q3A\/F\u65b0\u98ce\uff08350\u98ce\u91cf\uff09\",\"\u7a7a\u8c03\uff08\u8212\u4eab\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\uff09+ \u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff08\u4e91\u51c0\uff09\u4e24\u4f4d\u4e00\u4f53\"] },\n    { \"badge\":\"\u7cfb\u7edf\u4e8c\", \"title\":\"\u5c0a\u777f\u5168\u6548 + \u6c34\u6a21\u5757 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\", \"scope\":\"1F \u00b7 2F \u00b7 3F \u00b7 4F\",\n      \"items\":[\"\u5c0a\u777f\u5168\u6548280\u5916\u673a\uff08RAS-280FSXPNY5Q\uff09\",\"\u6c34\u6a21\u5757280\uff08RWMG-280FWNZ1Q\uff09\u7528\u5730\u6696\",\"\u4e09\u7ba1\u5236\u5185\u673a\u00d74\u53f0 + \u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a\u00d73\u53f0 + \u536b\u6d74\u7a7a\u8c03\",\"\u5730\u6696\u7cfb\u7edf250\u33a1\uff08179\u5143\/\u33a1\u8282\u80fd\u5b9a\u5236\uff09\"] }\n  ],\n  \/\/ \u8212\u4eab\u914d\u7f6e\u8868\uff1a\u6bcf\u884c [\u533a\u57df, \u9762\u79ef, \u5185\u673a\u578b\u53f7, \u51b7\u91cf, \u5907\u6ce8]\uff1b\u201c__HL__\u201d\u5f00\u5934=\u9ad8\u4eae\u6c47\u603b\u884c\n  \"\u8212\u4eab\u914d\u7f6e\u8868\": [\n    [\"\u8d1f\u4e8c\u697c \u00b7 \u5165\u6237\",\"35 \u33a1\",\"\u8212\u4eabRPIZ-36FSNAQD\/P\",\"3.6kW\",\"\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\"],\n    [\"\u8d1f\u4e8c\u697c \u00b7 \u591a\u529f\u80fd\u533a\",\"98 \u33a1\",\"\u8212\u4eabRPIZ-71FSNAQD\/P\",\"7.1kW\",\"\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\"],\n    [\"\u8d1f\u4e00\u697c \u00b7 \u5a31\u4e50\u533a\",\"25 \u33a1\",\"\u8212\u4eabRPIZ-22FSNAQD\/P\",\"2.2kW\",\"\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\"],\n    [\"\u8d1f\u4e00\u697c \u00b7 \u5ba2\u623f\",\"10 \u33a1\",\"\u8212\u4eabRPIZ-22FSNAQD\/P\",\"2.2kW\",\"\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\"],\n    [\"__HL__\",{\"t\":\"\u5916\u673a\uff1a\u8212\u4eab RAS-125HRNAQ\uff0812.5kW\uff09\uff5c\u5185\u673a\u603b\u51b7\u91cf\uff1a3.6+7.1+2.2+2.2 = 15.1kW \u2192 \u8fde\u63a5\u7387121%\uff08\u5408\u7406\u8303\u56f4\uff09\",\"c\":5}]\n  ],\n  \/\/ \u4ea7\u54c1\u5c55\u793a\u5361\u7247\uff1a\u6bcf\u4e2a {img, title, desc, link}\n  \"\u4ea7\u54c1\u5361\": [\n    { \"img\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E6%97%A5%E7%AB%8B%E8%88%92%E4%BA%AB%E5%A4%96%E6%9C%BA-5.jpg\", \"title\":\"\u65e5\u7acb EX-\u8212\u4eab\u7cfb\u5217\", \"desc\":\"SET-FREE\u53cc\u8f6c\u5b50\u591a\u8054\u673a \u00b7 \u5168\u76f4\u6d41\u53d8\u9891 \u00b7 17dB\u8d85\u4f4e\u9759\u97f3 \u00b7 APF\u6700\u9ad86.1 \u00b7 \u5185\u673a\u53ef\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\uff08\u6700\u4f4e10\u2103\u72ec\u7acb\u9664\u6e7f\uff09\", \"link\":\"https:\/\/longmai-nt.com\/?page_id=1077\" },\n    { \"img\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E6%97%A5%E7%AB%8B%E4%BA%91%E5%87%80%E6%96%B0%E9%A3%8E04-17.jpg\", \"title\":\"\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce\u7cfb\u7edf\", \"desc\":\"\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362 \u00b7 PM2.5\u51c0\u5316\u7387\u226598% \u00b7 \u7eb3\u7c73\u9ad8\u5206\u5b50\u53ef\u6c34\u6d17\u82af\u4f53 \u00b7 \u6700\u4f4e19dB\u6781\u81f4\u9759\u97f3\", \"link\":\"https:\/\/longmai-nt.com\/?page_id=1758\" },\n    { \"img\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\", \"title\":\"\u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548\u2161\", \"desc\":\"\u884c\u4e1a\u9996\u6b3e\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 \u00b7 175L\/\u5929\u9664\u6e7f\u91cf \u00b7 \u5168\u98ce\u8def\u51c0\u5316\u8231 \u00b7 17dB\u6781\u81f4\u9759\u97f3\", \"link\":\"https:\/\/longmai-nt.com\/?page_id=1811\" }\n  ],\n  \/\/ \u5c0a\u777f\u914d\u7f6e\u8868\uff1a\u6bcf\u884c [\u697c\u5c42, \u533a\u57df, \u9762\u79ef, \u5185\u673a\u578b\u53f7, \u51b7\u91cf, \u5185\u673a\u7c7b\u578b]\n  \"\u5c0a\u777f\u914d\u7f6e\u8868\": [\n    [\"1F\",\"\u5ba2\u5385\",\"31 \u33a1\",\"RPIZ-40FSVNZ1QD\/PC\",\"4.0kW\",\"\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a\"],\n    [\"1F\",\"\u9910\u5385\",\"33 \u33a1\",\"RPIZ-45FSVNZ1QD\/PC\",\"4.5kW\",\"\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a\"],\n    [\"2F\",\"\u8336\u5ba4\",\"48 \u33a1\",\"RPIZ-71FSVNZ1QD\/PC\",\"7.1kW\",\"\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a\"],\n    [\"2F\",\"\u5c0f\u5b69\u623f\",\"26.6 \u33a1\",\"RPIZ-36FSVN2QB\/PC\",\"3.6kW\",\"\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\"],\n    [\"3F\",\"\u4e3b\u5367\",\"33 \u33a1\",\"RPIZ-40FSVN2QB\/PC\",\"4.0kW\",\"\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\"],\n    [\"3F\",\"\u4e66\u623f\",\"17 \u33a1\",\"RPIZ-25FSVN2QB\/PC\",\"2.5kW\",\"\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\"],\n    [\"4F\",\"\u4e3b\u5367\",\"37 \u33a1\",\"RPIZ-56FSVN2QB\/PC\",\"5.6kW\",\"\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\"],\n    [\"4F\",\"\u4e3b\u536b\",\"13 \u33a1\",\"RCIS-25FSWNQD\",\"2.5kW\",\"\u536b\u751f\u95f4\u4e13\u7528\u7a7a\u8c03\"],\n    [\"__HL__\",{\"t\":\"\u5916\u673a\uff1a\u5c0a\u777f\u5168\u6548 RAS-280FSXPNY5Q\uff0828.0kW\uff09\uff5c\u5185\u673a\u603b\u51b7\u91cf\uff1a33.8kW \u2192 \u8fde\u63a5\u7387121%\uff5c\u6c34\u6a21\u5757\uff1aRWMG-280FWNZ1Q\uff5c\u5730\u6696\uff1a\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8 250\u33a1\u00d7179\u5143\/\u33a1\",\"c\":6}]\n  ],\n  \/\/ \u7cbe\u5de5\u516d\u6b65\u6cd5\u8f6e\u64ad\u56fe\u7247\uff1a\u586b\u5199\u5bf9\u5e94\u65bd\u5de5\u5b9e\u62cd\u56feURL\uff0c\u7559\u7a7a\u5219\u4e0d\u663e\u793a\n  \"\u56fe_\u52d8\u6d4b\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/hlxglyt-fls-xckc-03.jpg\",\n  \"\u56fe_\u8bbe\u8ba1\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-vamzrftsllgxtylt-1.jpg\",\n  \"\u56fe_\u6750\u65991\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\",\n  \"\u56fe_\u6750\u65992\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\",\n  \"\u56fe_\u5b89\u88c51\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\",\n  \"\u56fe_\u5b89\u88c52\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\",\n  \"\u56fe_\u5b89\u88c53\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xhmpqk.jpg\",\n  \"\u56fe_\u5b89\u88c54\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-frdl.jpg\",\n  \"\u56fe_\u5b89\u88c55\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\",\n  \"\u56fe_\u5b89\u88c56\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\",\n  \"\u56fe_\u8c03\u8bd5\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\",\n  \"\u56fe_\u9a8c\u6536\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\",\n  \"\u56fe_\u6559\u5b66\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\",\n\n  \/* ---------- 5. S4 \u900f\u660e\u62a5\u4ef7\uff08\u4ef7\u683c\u4e00\u5f8b\u5f15\u6e90\u6307\u4ee402=page_id=662\uff09 ---------- *\/\n  \/\/ \u7cfb\u7edf\u4e00\u62a5\u4ef7\uff1a\u6bcf\u884c [\u5e8f\u53f7, \u8bbe\u5907\u540d\u79f0, \u578b\u53f7, \u9762\u4ef7, \u6298\u6263, \u6298\u540e\u4ef7, \u5b89\u88c5\u8d39, \u5c0f\u8ba1]\n  \"\u62a5\u4ef7\u7cfb\u7edf\u4e00\": [\n    [1,\"\u8212\u4eab\u5ba4\u5916\u673a\",\"RAS-125HRNAQ\",11663,\"8\u6298\",9330,\"\u5df2\u542b\",9330],\n    [2,\"\u8212\u4eab\u5185\u673a36\",\"RPIZ-36FSNAQD\/P\",3125,\"8\u6298\",2500,1600,4100],\n    [3,\"\u8212\u4eab\u5185\u673a71\",\"RPIZ-71FSNAQD\/P\",3513,\"8\u6298\",2810,1600,4410],\n    [4,\"\u8212\u4eab\u5185\u673a22\",\"RPIZ-22FSNAQD\/P\",3013,\"8\u6298\",2410,1600,4010],\n    [5,\"\u8212\u4eab\u5185\u673a22\",\"RPIZ-22FSNAQD\/P\",3013,\"8\u6298\",2410,1600,4010],\n    [6,\"\u4f4e\u6e29\u9664\u6e7f\u5305\u00d74\",\"\u9009\u914d\",{\"html\":\"\u5f85\u786e\u8ba4\u4ef7\u683c\uff0c\u6309\u9f99\u8109\u8f85\u6750\u6807\u51c6\u8ba1\",\"c\":5}],\n    [\"__HL__\",{\"t\":\"\u8212\u4eab\u7cfb\u7edf\u5c0f\u8ba1\uff08\u4e0d\u542b\u9664\u6e7f\u5305\uff09\",\"c\":7},38060]\n  ],\n  \/\/ \u7cfb\u7edf\u4e8c\u00b7\u4e3b\u673a+\u6c34\u6a21\u5757\uff1a\u6bcf\u884c [\u5e8f\u53f7, \u8bbe\u5907\u540d\u79f0, \u578b\u53f7, \u9762\u4ef7, \u6298\u6263, \u6298\u540e\u4ef7, \u5b89\u88c5\u8d39, \u5c0f\u8ba1]\n  \"\u62a5\u4ef7\u4e3b\u673a\": [\n    [1,\"\u5c0a\u777f\u5168\u6548\u5ba4\u5916\u673a\",\"RAS-280FSXPNY5Q\",34788,\"8.5\u6298\",29570,600,30170],\n    [2,\"\u6c34\u6a21\u5757280\",\"RWMG-280FWNZ1Q\",12700,\"\u4e0d\u6253\u6298\",12700,625,13325],\n    [\"__HL__\",{\"t\":\"\u4e3b\u673a\u5c0f\u8ba1\",\"c\":7},43495]\n  ],\n  \/\/ \u7cfb\u7edf\u4e8c\u00b7\u5ba4\u5185\u673a\uff1a\u6bcf\u884c [\u5e8f\u53f7, \u533a\u57df, \u578b\u53f7, \u9762\u4ef7, 8.5\u6298\u540e, \u5b89\u88c5\u8d39, \u5c0f\u8ba1]\n  \"\u62a5\u4ef7\u5185\u673a\": [\n    [3,\"1F\u5ba2\u5385\uff08\u4e24\u7ba1\u5236\u51c0\u5316\uff09\",\"RPIZ-40FSVNZ1QD\/PC\",4800,4080,1600,5680],\n    [4,\"1F\u9910\u5385\uff08\u4e24\u7ba1\u5236\u51c0\u5316\uff09\",\"RPIZ-45FSVNZ1QD\/PC\",5088,4325,1600,5925],\n    [5,\"2F\u8336\u5ba4\uff08\u4e24\u7ba1\u5236\u51c0\u5316\uff09\",\"RPIZ-71FSVNZ1QD\/PC\",5238,4452,1600,6052],\n    [6,\"2F\u5c0f\u5b69\u623f\uff08\u4e09\u7ba1\u5236\uff09\",\"RPIZ-36FSVN2QB\/PC\",5238,4452,1900,6352],\n    [7,\"3F\u4e3b\u5367\uff08\u4e09\u7ba1\u5236\uff09\",\"RPIZ-40FSVN2QB\/PC\",5238,4452,1900,6352],\n    [8,\"3F\u4e66\u623f\uff08\u4e09\u7ba1\u5236\uff09\",\"RPIZ-25FSVN2QB\/PC\",5050,4293,1900,6193],\n    [9,\"4F\u4e3b\u5367\uff08\u4e09\u7ba1\u5236\uff09\",\"RPIZ-56FSVN2QB\/PC\",5663,4814,1900,6714],\n    [10,\"4F\u4e3b\u536b\uff08\u536b\u6d74\u7a7a\u8c03\uff09\",\"RCIS-25FSWNQD\",7088,7088,1600,8688],\n    [\"__HL__\",{\"t\":\"\u5ba4\u5185\u673a\u5c0f\u8ba1\",\"c\":6},51956]\n  ],\n  \/\/ \u7cfb\u7edf\u4e8c\u00b7\u5730\u6696\uff1a\u6bcf\u884c [\u9879\u76ee, \u89c4\u683c, \u5355\u4ef7, \u9762\u79ef, \u5c0f\u8ba1]\n  \"\u62a5\u4ef7\u5730\u6696\": [\n    [\"\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8\",\"De32\u4e3b\u7ba1+De20\u76d8\u7ba1\/\u4f1f\u661f\u963b\u6c27\u7ba1\/\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236\",\"179\u5143\/\u33a1\",\"250\u33a1\",44750],\n    [\"__HL__\",{\"t\":\"\u5730\u6696\u5c0f\u8ba1\",\"c\":4},44750]\n  ],\n  \/\/ \u7cfb\u7edf\u4e8c\u00b7\u6c47\u603b\uff08\u997c\u56fe\u81ea\u52a8\u53d6\u524d4\u9879\u91d1\u989d\uff09\uff1a\u6bcf\u884c [\u9879\u76ee, \u91d1\u989d]\n  \"\u62a5\u4ef7\u6c47\u603b\": [\n    [\"\u7cfb\u7edf\u4e00\uff1a\u8212\u4eab\u4e00\u62d6\u56db+\u65b0\u98ce\uff08\u4e0d\u542b\u9664\u6e7f\u5305\uff09\",38060],\n    [\"\u7cfb\u7edf\u4e8c\uff1a\u5c0a\u777f\u5168\u6548\u5916\u673a+\u6c34\u6a21\u5757\",43495],\n    [\"\u7cfb\u7edf\u4e8c\uff1a\u5ba4\u5185\u673a8\u53f0\",51956],\n    [\"\u7cfb\u7edf\u4e8c\uff1a\u5730\u6696\u7cfb\u7edf250\u33a1\",44750],\n    [\"__HL__\",{\"t\":\"\u8bbe\u5907\u5408\u8ba1\",\"c\":1},178261]\n  ],\n\n  \/* ---------- 6. 20\u5e74\u5168\u5468\u671f\u603b\u8d26 ---------- *\/\n  \"20\u5e74\": {\n    \"\u7535\u4ef7\": \"0.52\u5143\/kWh\", \"\u6c14\u4ef7\": \"3.4\u5143\/m\u00b3\",\n    \"\u6708\u8d39A\": \"\u2248\u00a5300\", \"\u6708\u8d39B\": \"\u2248\u00a5333\",\n    \"\u5e74\u8d39A\": 3600, \"\u5e74\u8d39B\": 4000,\n    \"\u5bff\u547dA\": 18, \"\u5bff\u547dB\": 18,\n    \"\u66f4\u6362A\": 112161, \"\u66f4\u6362B\": 120000,\n    \"\u8d2d\u7f6eA\": 140201, \"\u8d2d\u7f6eB\": 150000\n  },\n  \"20\u5e74\u88681\": [\n    [\"\u53d6\u503c\u8bf4\u660e\uff08\u6c14\u4ef7\/\u7535\u4ef7\uff09\",\"\u6210\u90fd\u7535\u4ef7 0.52\u5143\/kWh\uff08\u71c3\u6c143.4\u5143\/m\u00b3\u4ec5\u5f53\u914d\u7f6e\u71c3\u6c14\u8f85\u70ed\u00b7\u672c\u6848\u672a\u914d\u7f6e\uff09\",\"\u540c\u5de6\"],\n    [\"\u4f30\u7b97\u6708\u8fd0\u884c\u8d39\",\"\u2248\u00a5300\uff08\u4f30\u7b97\u00b7\u4ee5\u5b9e\u9645\u4e3a\u51c6\uff09\",\"\u2248\u00a5333\uff08\u4f30\u7b97\u00b7\u5f85\u786e\u8ba4\uff09\"],\n    [\"\u5e74\u8fd0\u884c\u8d39 = \u6708\u8d39\u00d712\",\"\u2248\u00a53,600\",\"\u2248\u00a54,000\uff08\u5f85\u786e\u8ba4\uff09\"]\n  ],\n  \"20\u5e74\u88682\": [\n    [\"\u70ed\u6e90\uff08\u4e3b\u673a\uff09\u6807\u79f0\u5bff\u547d\",\"15-20\u5e74\uff08\u53d618\u5e74\u00b7\u4ea7\u54c1\u6807\u79f0+\u767d\u76ae\u4e66\uff09\",\"15-20\u5e74\uff08\u4f30\u7b97\uff09\"],\n    [\"\u9884\u8ba1\u66f4\u6362\u5e74\u4efd\",\"\u7b2c18\u5e74\uff08\u4f30\u7b97\uff09\",\"\u7b2c18\u5e74\uff08\u4f30\u7b97\uff09\"],\n    [\"\u66f4\u6362\u8d39\u7528 = \u521d\u6295\u8d44\u00d7(0.7~0.9)\uff0c\u53d60.8\",\"\u2248\u00a5112,161\uff08140,201\u00d70.8\uff09\",\"\u2248\u00a5120,000\uff08\u5f85\u786e\u8ba4\uff09\"]\n  ],\n  \"20\u5e74\u88683\": [\n    [\"\u521d\u6295\u8d44\uff08\u8d2d\u7f6e\uff09\",\"\u00a5140,201\uff08\u5f15\u6e90662\uff09\",\"\u00a5150,000\uff08\u5f85\u786e\u8ba4\uff09\",\"\u5c0a\u777f\u7565\u4f18\"],\n    [\"20\u5e74\u8fd0\u884c\u8d39\uff08\u7528\u8d39\uff09\",\"\u00a572,000\",\"\u00a580,000\uff08\u5f85\u786e\u8ba4\uff09\",\"\u5c0a\u777f\u7701\u00a58,000\"],\n    [\"20\u5e74\u7ef4\u62a4\u8d39\uff08\u7ef4\u4fdd\uff09\",\"\u00a520,000\",\"\u00a524,000\uff08\u5f85\u786e\u8ba4\uff09\",\"\u5c0a\u777f\u7701\u00a54,000\"],\n    [\"\u70ed\u6e90\u66f4\u6362\u8d39\uff08\u7b2c18\u5e74\uff09\",\"\u00a5112,161\",\"\u00a5120,000\uff08\u5f85\u786e\u8ba4\uff09\",\"\u5c0a\u777f\u7701\u7ea6\u00a57,839\"],\n    [\"__HL__\",\"20\u5e74\u603b\u6295\u5165\",\"\u00a5344,362\",\"\u00a5374,000\uff08\u5f85\u786e\u8ba4\uff09\",\"\u5c0a\u777f\u5168\u751f\u547d\u5468\u671f\u8282\u7701\u7ea6\u00a52.96\u4e07\"],\n    [\"\u5dee\u989d\u7ed3\u8bba\",\"\u2014\",\"\u2014\",\"\u6c34\u5885\u9002\u8f83\u5c0a\u777f\u9ad8\u7ea6 +\u00a529,638\"],\n    [\"\u56de\u672c\u5468\u671f\",{\"t\":\"\u5c0a\u777f\u521d\u59cb\u4e0e\u8fd0\u7ef4\u53cc\u4f18\u3001\u65e0\u6ea2\u4ef7 \u2192 \u5168\u7a0b\u5373\u7701\uff0c\u65e0\u56de\u672c\u5468\u671f\uff08\u63a8\u8350\u5c0a\u777f\uff09\",\"c\":3}]\n  ],\n  \"20\u5e74\u5dee\u989d\u7ed3\u8bba\": \"\u6c34\u5885\u900220\u5e74\u603b\u6295\u5165\u7ea6\u9ad8 +\u00a529,638\uff1b\u5c0a\u777f\u521d\u59cb\u4e0e\u8fd0\u7ef4\u53cc\u4f18\u3001\u65e0\u56de\u672c\u5468\u671f\uff08\u63a8\u8350\uff09\u3002\",\n\n  \/* ---------- 7. S5 \u6848\u4f8b\u9a8c\u8bc1 ---------- *\/\n  \/\/ \u6848\u4f8b\u8868\uff1a\u6bcf\u884c [\u540d\u79f0\u5bf9\u8c61, \u9762\u79ef, \u914d\u7f6e, \u8fd0\u884c\u6570\u636e, \u53c2\u8003\u4ef7\u503c]\uff1b\u540d\u79f0\u7528 {\"t\":\"\u540d\",\"link\":\"url\"}\n  \"\u6848\u4f8b\u8868\": [\n    [{\"t\":\"\u548c\u8d35\u5357\u5c71\u4e0a\u00b7\u8f9b\u603b\u522b\u5885\",\"link\":\"https:\/\/longmai-nt.com\/?page_id=448\"},\"600\u33a1\",\"\u65e5\u7acb\u5c0a\u777f504\u4e3b\u673a+\u745e\u7f8e\u53cc\u51b7\u51dd\u9505\u7089+15\u53f0\u5185\u673a\",\"\u5730\u6696\u6708\u8d39\u4e0d\u52302000\u5143\",\"\u522b\u5885\u5927\u5b85\u7cfb\u7edf\u6807\u6746\"],\n    [{\"t\":\"\u84dd\u82b1\u6979\u00b7\u8a89\u5cf0\u5927\u5e73\u5c42\",\"link\":\"https:\/\/longmai-nt.com\/case\/yufeng.html\"},\"220\u33a1\",\"24kW\u53d8\u9891\u7089+\u53bb\u8026\u7f50+\u5ba4\u6e29\u8054\u52a8\uff08\u8282\u80fd\u6539\u9020\uff09\",\"\u8282\u80fd30%-50%\",\"\u529f\u7387\u5339\u914d\u8282\u80fd\u9a8c\u8bc1\"],\n    [{\"t\":\"\u9e93\u6e56\u751f\u6001\u57ce\u00b7\u5468\u8001\u5e08\",\"link\":\"https:\/\/longmai-nt.com\/?page_id=540\"},\"98.8\u33a1\u91c7\u6696\",\"\u745e\u7f8e\u53cc\u51b7\u51dd\u7089+\u4f1f\u661f\u7ba1\u9053+\u66fc\u745e\u5fb7\u8054\u52a8\",\"\u91c7\u6696\u5b63\u6708\u71c3\u6c14\u8d39\u4f4e\u4e8e\u5e02\u573a\u5747\u503c\",\"\u5168\u6d41\u7a0b\u6863\u6848\u6807\u6746\"]\n  ],\n  \"\u552e\u540e\u5206\u7ec4\": \"A\u7ec4\uff08\u8282\u80fd\u65b9\u6848\u7ec4\uff09\",\n\n  \/* ---------- 8. \u8054\u7cfb\u6211\u4eec \/ SEO ---------- *\/\n  \"\u987e\u95ee\u59d3\u540d\": \"\u4f59\u6653\u73b2\",\n  \"\u987e\u95ee\u7535\u8bdd\": \"130-0811-3409\",\n  \"seo\u6807\u9898\": \"\u6210\u90fd{{\u5ba2\u6237\u59d3\u540d}}{{\u9879\u76ee\u7c7b\u578b}}\uff5c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u65b9\u6848\uff5c\u9f99\u8109\u6696\u901a\",\n  \"seo\u63cf\u8ff0\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\u4e3a{{\u5ba2\u6237\u59d3\u540d}}{{\u9879\u76ee\u7c7b\u578b}}\u5b9a\u5236\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b\u65b9\u6848\uff0c\u900f\u660e\u62a5\u4ef7+20\u5e74\u603b\u8d26\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5\u3002\"\n};\nwindow.PROJECT = PROJECT;\n<\/script>\n\n<!-- ========== \u4e3b\u4f53\u5bb9\u5668 ========== -->\n<div class=\"lm-container\">\n<noscript><style>.lm-flip-inner{transform:rotateY(180deg)!important;} .lm-chart-fallback{display:block!important;} .lm-flip-cap{display:none!important;}<\/style><\/noscript>\n\n<!-- ===== \u5c01\u9762 ===== -->\n<section class=\"lm-section lm-cover\" id=\"cover\">\n  <h1>{{\u5ba2\u6237\u59d3\u540d}}{{\u9879\u76ee\u7c7b\u578b}} \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66<\/h1>\n  <p class=\"lm-sub\">\u8212\u9002\u5065\u5eb7 \u00b7 \u8282\u80fd\u7a33\u5b9a \u00b7 \u7ef4\u62a4\u7b80\u4fbf<\/p>\n  <div class=\"lm-meta\">\n    <span>\u5ba2\u6237\uff1a{{\u5ba2\u6237\u59d3\u540d}}<\/span>\n    <span>\u7269\u4e1a\u7c7b\u578b\uff1a{{\u7269\u4e1a\u7c7b\u578b}}\uff08{{\u697c\u5c42\u63cf\u8ff0}}\uff09<\/span>\n    <span>\u91c7\u6696\u9762\u79ef\uff1a{{\u91c7\u6696\u9762\u79ef}}<\/span>\n    <span>\u5e38\u4f4f\u4eba\u53e3\uff1a{{\u5e38\u4f4f\u4eba\u53e3}}<\/span>\n    <span>\u65e5\u671f\uff1a{{\u65e5\u671f}}<\/span>\n  <\/div>\n  <div class=\"lm-meta\" style=\"margin-top:8px;\">\n    <span class=\"lm-brand-tag\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u8bb8\u7ecf\u9500\u5546<\/span>\n  <\/div>\n<\/section>\n\n<!-- ========== \u76ee\u5f55\u5bfc\u822a\uff08\u5c01\u9762\u4e0b\u65b9\u00b7sticky\uff09 ========== -->\n<nav class=\"lm-toc-bar\">\n  <a class=\"lm-toc-item lm-active\" href=\"#cover\">\u5c01\u9762<\/a>\n  <a class=\"lm-toc-item\" href=\"#s1\">S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/a>\n  <a class=\"lm-toc-item\" href=\"#s2\">S2\u00b7\u65b9\u6848\u8bca\u65ad<\/a>\n  <a class=\"lm-toc-item\" href=\"#compare-six\">\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/a>\n  <a class=\"lm-toc-item\" href=\"#s3\">S3\u00b7\u7cfb\u7edf\u8bbe\u8ba1<\/a>\n  <a class=\"lm-toc-item\" href=\"#s4\">S4\u00b7\u900f\u660e\u62a5\u4ef7<\/a>\n  <a class=\"lm-toc-item\" href=\"#compare-20y\">20\u5e74\u5168\u5468\u671f<\/a>\n  <a class=\"lm-toc-item\" href=\"#s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1<\/a>\n  <a class=\"lm-toc-item\" href=\"#sa\">\u9644\u5f55\u00b7\u54c1\u724c\u6388\u6743<\/a>\n  <a class=\"lm-toc-item\" href=\"#s10\">\u8054\u7cfb\u6211\u4eec<\/a>\n<\/nav>\n\n<!-- ===== S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 ===== -->\n<section class=\"lm-section\" id=\"s1\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S1<\/span>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n  <div class=\"lm-info-grid\">\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u9879\u76ee\u5730\u5740<\/div><div class=\"lm-value\">{{\u9879\u76ee\u5730\u5740}}<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5efa\u7b51\u5c42\u6570<\/div><div class=\"lm-value\">{{\u697c\u5c42\u63cf\u8ff0}}<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u91c7\u6696\u9762\u79ef<\/div><div class=\"lm-value\">{{\u91c7\u6696\u9762\u79ef}}<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5e38\u4f4f\u4eba\u53e3<\/div><div class=\"lm-value\">{{\u5e38\u4f4f\u4eba\u53e3}}<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5730\u4e0b\u5ba4\u9762\u79ef<\/div><div class=\"lm-value\">{{\u5730\u4e0b\u5ba4\u9762\u79ef}}<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u7a7a\u8c03\u9700\u6c42<\/div><div class=\"lm-value\">{{\u7a7a\u8c03\u9700\u6c42}}<\/div><\/div>\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u6838\u5fc3\u8bc9\u6c42<\/h3>\n  <div class=\"lm-highlight\"><strong>{{\u5ba2\u6237\u59d3\u540d}}\u8981\u6c42\uff1a<\/strong>{{\u6838\u5fc3\u8bc9\u6c42}}<\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u8bca\u65ad\u5206\u6790<\/h3>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:22%;\">\u75db\u70b9\/\u95ee\u9898<\/th><th style=\"width:38%;\">\u8868\u73b0<\/th><th style=\"width:40%;\">\u5e94\u5bf9\u7b56\u7565<\/th><\/tr>\n    <tbody data-render=\"\u8bca\u65ad\u8868\"><\/tbody>\n  <\/table>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u5730\u4e0b\u5ba4\u65b9\u6848\u5206\u6790<\/h3>\n  <div class=\"lm-highlight-blue\">\n    <strong>\u5173\u4e8e\u539f\u5b9a\u67dc\u6302\u673a\u65b9\u6848\u7684\u7814\u5224\uff1a<\/strong><br>\n    {{\u5730\u4e0b\u5ba4\u7814\u5224}}\n  <\/div>\n<\/section>\n\n<!-- ===== S2\u00b7\u65b9\u6848\u8bca\u65ad ===== -->\n<section class=\"lm-section\" id=\"s2\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S2<\/span>\u65b9\u6848\u8bca\u65ad<\/div>\n\n  <p style=\"margin-bottom:16px;color:var(--lm-text2);\">\u9488\u5bf9{{\u5ba2\u6237\u59d3\u540d}}\u201c\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355\u201d\u7684\u6838\u5fc3\u8bc9\u6c42\uff0c\u4ee5\u4e0b\u4ece<strong style=\"color:var(--lm-gold2);\">{{\u65b9\u6848A\u540d}}<\/strong>\u4e0e<strong style=\"color:var(--lm-gold2);\">{{\u65b9\u6848B\u540d}}<\/strong>\u5c55\u5f00\u5206\u7ef4\u5ea6\u8bca\u65ad\uff0c\u6309\u201c\u4f53\u9a8c \/ \u6280\u672f \/ \u8fd0\u7ef4\u201d\u4e09\u7c7b\u5207\u6362\u67e5\u770b\u3002<\/p>\n\n  <div class=\"lm-tabs-nav\">\n    <button class=\"lm-tab-btn lm-active\" data-tab=\"t1\">\u4f53\u9a8c\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t2\">\u6280\u672f\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t3\">\u8fd0\u7ef4\u7ef4\u5ea6<\/button>\n  <\/div>\n\n  <div class=\"lm-tab-panel lm-active\" id=\"t1\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:16%;\">\u7ef4\u5ea6<\/th><th style=\"width:38%;\">{{\u65b9\u6848A\u540d}}\uff08\u63a8\u8350\uff09<\/th><th style=\"width:38%;\">{{\u65b9\u6848B\u540d}}<\/th><th style=\"width:8%;\">\u7ed3\u8bba<\/th><\/tr>\n      <tbody data-render=\"S2\u4f53\u9a8c\u8868\"><\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t2\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:16%;\">\u7ef4\u5ea6<\/th><th style=\"width:38%;\">{{\u65b9\u6848A\u540d}}\uff08\u63a8\u8350\uff09<\/th><th style=\"width:38%;\">{{\u65b9\u6848B\u540d}}<\/th><th style=\"width:8%;\">\u7ed3\u8bba<\/th><\/tr>\n      <tbody data-render=\"S2\u6280\u672f\u8868\"><\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t3\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:16%;\">\u7ef4\u5ea6<\/th><th style=\"width:38%;\">{{\u65b9\u6848A\u540d}}\uff08\u63a8\u8350\uff09<\/th><th style=\"width:38%;\">{{\u65b9\u6848B\u540d}}<\/th><th style=\"width:8%;\">\u7ed3\u8bba<\/th><\/tr>\n      <tbody data-render=\"S2\u8fd0\u7ef4\u8868\"><\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-highlight\" style=\"margin:20px 0;\">\n    <strong>\u7efc\u5408\u7ed3\u8bba\uff1a<\/strong>{{\u7efc\u5408\u7ed3\u8bba}}\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u9002\u7528\u60c5\u666f\u5bf9\u6bd4\u901f\u67e5<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u5ba2\u6237\u573a\u666f<\/th><th>\u63a8\u8350\u65b9\u6848<\/th><th>\u7406\u7531<\/th><\/tr>\n    <tr><td>\u5bf9\u9664\u6e7f\u6709\u521a\u9700\uff08\u6210\u90fd\u6885\u96e8\u5b63\/\u5730\u4e0b\u5ba4\uff09<\/td><td><span class=\"lm-tag lm-tag-blue\">{{\u65b9\u6848A\u7b80\u79f0}}<\/span><\/td><td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/td><\/tr>\n    <tr><td>\u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\uff0c\u6015\u51b7\u98ce\u76f4\u5439<\/td><td><span class=\"lm-tag lm-tag-orange\">{{\u65b9\u6848B\u7b80\u79f0}}<\/span><\/td><td>\u51fa\u98ce15-20\u2103\u66f4\u67d4\u548c<\/td><\/tr>\n    <tr><td>\u9700\u8981\u81ea\u6e05\u6d01+\u7a7a\u6c14\u51c0\u5316<\/td><td><span class=\"lm-tag lm-tag-blue\">{{\u65b9\u6848A\u7b80\u79f0}}<\/span><\/td><td>\u6807\u914dPE\u51c0\u5316+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><\/tr>\n    <tr><td>\u8ffd\u6c42\u6781\u7b80\u7ef4\u62a4<\/td><td><span class=\"lm-tag lm-tag-blue\">{{\u65b9\u6848A\u7b80\u79f0}}<\/span><\/td><td>\u6c1f\u7cfb\u7edf\u7a33\u5b9a\uff0c\u81ea\u6e05\u6d01\u51cf\u5c11\u4eba\u5de5\u7ef4\u62a4<\/td><\/tr>\n    <tr><td>\u5927\u7a7a\u95f4\u65e0\u5185\u673a\u8fde\u63a5\u7387\u9650\u5236\u9700\u6c42<\/td><td><span class=\"lm-tag lm-tag-orange\">{{\u65b9\u6848B\u7b80\u79f0}}<\/span><\/td><td>\u8fde\u63a5\u7387\u53ef\u8d85200%\uff0c\u7075\u6d3b\u6027\u5f3a<\/td><\/tr>\n  <\/table>\n\n  <!-- ===== \u516d\u7ef4\u5ea6\u5bf9\u6bd4\u5206\u6790\u7ffb\u8f6c\u5361 ===== -->\n  <div class=\"lm-flip-card\" id=\"compare-six\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\">\n        <div class=\"lm-flip-title\">\u516d\u7ef4\u5ea6\u5bf9\u6bd4\u5206\u6790 \u00b7 \u96f7\u8fbe\u56fe\uff08\u5f52\u4e00\u5316\u00b7\u8d8a\u5927\u8d8a\u4f18\uff09<\/div>\n        <div id=\"chart-six\"><\/div>\n        <div class=\"lm-chart-fallback\">\ud83d\udcca \u6b64\u96f7\u8fbe\u56fe\u9700\u542f\u7528 JavaScript \u67e5\u770b\uff1b\u516d\u7ef4\u5ea6\u539f\u59cb\u6570\u503c\u4e0e\u7ed3\u8bba\u89c1\u80cc\u9762\u8868\u683c\u3002<\/div>\n        <div class=\"lm-flip-cap\">\u60ac\u505c\u6216\u70b9\u51fb\u4e0b\u65b9\u5361\u7247\u7ffb\u8f6c \u2192 \u67e5\u770b\u516d\u7ef4\u5ea6\u6570\u503c\u8be6\u60c5<\/div>\n      <\/div>\n      <div class=\"lm-flip-back\">\n        <div class=\"lm-flip-tip\">\u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u56fe\u8868 \u21bb<\/div>\n        <div class=\"lm-flip-title\">\u516d\u7ef4\u5ea6\u5bf9\u6bd4\u5206\u6790 \u00b7 \u6570\u503c\u8be6\u60c5<\/div>\n        <table class=\"lm-table\">\n          <tr><th>\u7ef4\u5ea6\uff08\u987a\u5e8f\u56fa\u5b9a\uff09<\/th><th>{{\u65b9\u6848A\u540d}}<\/th><th>{{\u65b9\u6848B\u540d}}<\/th><th>\u7ed3\u8bba<\/th><\/tr>\n          <tbody data-render=\"\u516d\u7ef4\u8868\"><\/tbody>\n        <\/table>\n        <p style=\"font-size:12px;color:var(--lm-text2);margin-top:10px;\">\u8bf4\u660e\uff1a\u96f7\u8fbe\u56fe\u4e3a\u516d\u7ef4\u5ea6\u5f52\u4e00\u5316\u7efc\u5408\u5f97\u5206\uff08\u6ee1\u5206100\uff0c\u8d8a\u5927\u8d8a\u4f18\uff1b\u6210\u672c\u7c7b\u8f74\u5df2\u53cd\u5411\uff09\u3002\u539f\u59cb\u6570\u503c\u5982\u4e0a\uff0c\u7f3a\u5931\u9879\u6807\u300c\u5f85\u52d8\u6d4b\/\u5f85\u786e\u8ba4\u300d\u4e0d\u7f16\u9020\u3002\u5f15\u6e90\uff1aS2\u8bca\u65ad\u6587\u5b57 + S4\u62a5\u4ef7\uff08\u6307\u4ee402\u00b7page_id=662\uff09\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== S3\u00b7\u7cfb\u7edf\u8bbe\u8ba1 ===== -->\n<section class=\"lm-section\" id=\"s3\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S3<\/span>\u7cfb\u7edf\u8bbe\u8ba1<\/div>\n\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u67b6\u6784\u603b\u89c8<\/h3>\n  <div class=\"lm-compare-grid\" data-render=\"\u7cfb\u7edf\u5361\" data-type=\"cards\"><\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c \u00b7 \u8212\u4eab\u4e00\u62d6\u56db\u914d\u7f6e<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <tbody data-render=\"\u8212\u4eab\u914d\u7f6e\u8868\"><\/tbody>\n  <\/table>\n\n  <div class=\"lm-highlight-blue\" style=\"margin:16px 0;\">\n    <strong>\u4f4e\u6e29\u9664\u6e7f\u5305\u8bf4\u660e\uff1a<\/strong>\u8212\u4eab\u5185\u673a\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\u540e\uff0c\u53ef\u5728\u6700\u4f4e10\u2103\u73af\u5883\u4e0b\u72ec\u7acb\u9664\u6e7f\uff0c\u6709\u6548\u89e3\u51b3\u6210\u90fd\u6885\u96e8\u5b63\u5730\u4e0b\u5ba4\u6f6e\u6e7f\u53d1\u9709\u3002\u4e91\u51c0KPI-3521Q3A\/F\u4e3a\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u8d1f\u8d23\u901a\u98ce\u6362\u6c14\u4e0ePM2.5\u51c0\u5316\uff08\u226598%\uff09\uff0c\u4e0e\u9664\u6e7f\u5305\u5206\u5de5\u660e\u786e\uff1a<strong style=\"color:var(--lm-gold2);\">\u9664\u6e7f\u9760\u5185\u673a\u9664\u6e7f\u5305\uff0c\u901a\u98ce\u6362\u6c14\u9760\u4e91\u51c0\u65b0\u98ce<\/strong>\u3002\u76f8\u6bd4\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\u4e00\u4f53\u673a\u6027\u4ef7\u6bd4\u66f4\u9ad8\u3002\n  <\/div>\n\n  <div class=\"lm-prod-showcase\" data-render=\"\u4ea7\u54c1\u5361\" data-type=\"products\"><\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">1F-4F \u00b7 \u5c0a\u777f\u5168\u6548\u4e8c\u8054\u4f9b\u914d\u7f6e<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u5185\u673a\u7c7b\u578b<\/th><\/tr>\n    <tbody data-render=\"\u5c0a\u777f\u914d\u7f6e\u8868\"><\/tbody>\n  <\/table>\n\n  <div class=\"lm-highlight-green\" style=\"margin:16px 0;\">\n    <strong>\u8bbe\u8ba1\u539f\u5219\uff1a<\/strong>\u6309GEO\u4e94\u6b65\u6cd5\u89c4\u8303\u8bbe\u8ba1\uff0c\u4e25\u683c\u9075\u5faaGB 50736-2012\u5236\u51b7\u8d1f\u8377\u6807\u51c6\uff08\u522b\u5885\u7c7b80-120W\/\u33a1\uff09\uff0c\u907f\u514d\u201c\u5927\u9a6c\u62c9\u5c0f\u8f66\u201d\u3002\u8fde\u63a5\u7387\u63a7\u5236\u5728\u5408\u7406\u8303\u56f4\uff0c\u65e2\u4fdd\u8bc1\u5168\u5f00\u65f6\u6548\u679c\u4e0d\u6253\u6298\uff0c\u4e5f\u907f\u514d\u5355\u5f00\u623f\u95f4\u9891\u7e41\u542f\u505c\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cbe\u5de5\u516d\u6b65\u6cd5 + 2 \u6807\u51c6\u5316\u65bd\u5de5<\/h3>\n  <div class=\"lm-step-flow\">\n    <span class=\"lm-step\">01 \u73b0\u573a\u52d8\u6d4b<\/span>\n    <span class=\"lm-step\">02 \u7cfb\u7edf\u8bbe\u8ba1<\/span>\n    <span class=\"lm-step\">03 \u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/span>\n    <span class=\"lm-step\">04 \u7cfb\u7edf\u5b89\u88c5<\/span>\n    <span class=\"lm-step\">05 \u7cfb\u7edf\u8c03\u8bd5<\/span>\n    <span class=\"lm-step\">06 \u7ae3\u5de5\u9a8c\u6536<\/span>\n    <span class=\"lm-step\">+1 \u4ea4\u4ed8\u6559\u5b66<\/span>\n    <span class=\"lm-step\">+2 \u552e\u540e\u4fdd\u969c<\/span>\n  <\/div>\n\n  <div class=\"lm-carousel\" id=\"lmCraftCarousel\">\n    <div class=\"lm-carousel-track\">\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">01<\/span><div class=\"lm-cs-title\">\u73b0\u573a\u52d8\u6d4b<\/div><\/div>\n        <div class=\"lm-cs-body\">\u8bbe\u8ba1\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u6237\u578b\u7ed3\u6784\u3001\u5c42\u9ad8\u3001\u5916\u673a\u4f4d\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\uff0c\u7cbe\u786e\u6d4b\u91cf\u5404\u623f\u95f4\u9762\u79ef\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u52d8\u6d4b\u62a5\u544a + \u73b0\u573a\u7167\u7247\u5b58\u6863<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"{{\u56fe_\u52d8\u6d4b}}\" alt=\"\u73b0\u573a\u52d8\u6d4b\u5b9e\u666f\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u73b0\u573a\u52d8\u6d4b<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">02<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u8bbe\u8ba1<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6839\u636e\u52d8\u6d4b\u6570\u636e\u8ba1\u7b97\u70ed\u8d1f\u8377\uff0c\u7ed8\u5236\u76d8\u7ba1\u5e03\u7f6e\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u56fe\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u8bbe\u8ba1\u56fe\u7eb8\u7ecf\u5ba2\u6237\u786e\u8ba4\u540e\u65bd\u5de5<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"{{\u56fe_\u8bbe\u8ba1}}\" alt=\"\u7cfb\u7edf\u8bbe\u8ba1\u793a\u610f\u56fe\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u7cfb\u7edf\u8bbe\u8ba1\u65b9\u6848<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">03<\/span><div class=\"lm-cs-title\">\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6240\u6709\u7ba1\u6750\u3001\u4fdd\u6e29\u6750\u6599\u4e0e\u5ba2\u6237\u5171\u540c\u6838\u9a8c\u54c1\u724c\u578b\u53f7\u89c4\u683c\uff0c\u94dc\u7ba1\u58c1\u539a\u9010\u6839\u6d4b\u91cf\u7559\u75d5\uff0c\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u5373\u9a8c\u6536\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\uff0c\u7559\u5b58\u6750\u6599\u7167\u7247<\/div>\n        <div class=\"lm-cs-imgs\">\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u6750\u65991}}\" alt=\"\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u6750\u65992}}\" alt=\"\u94dc\u7ba1\u58c1\u539a\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c<\/figcaption><\/figure>\n        <\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">04<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u5b89\u88c5<\/div><\/div>\n        <div class=\"lm-cs-body\">\u94dc\u7ba1\u710a\u63a5\uff08\u5145\u6c2e\u4fdd\u62a4\uff09\u3001\u5206\u6b67\u7ba1\u5b89\u88c5\u3001\u4fdd\u6e29\u5305\u88f9\u3001\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u3001\u6253\u538b\u6d4b\u8bd5\u3002\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\u56fa\u5b9a\uff0c\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\u6392\u5e03\u5e76\u8bbe\u6392\u6c14\u5b54\u3001\u6807\u51c6\u63a5\u5165\u5730\u6f0f\uff0c\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\u3001\u6c2e\u6c14\u4fdd\u538b\u5168\u7a0b\u7559\u75d5\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u6253\u538b 0.6-0.8MPa\uff0c\u7a33\u538b\u22651h\uff0c\u538b\u964d\u22640.05MPa<\/div>\n        <div class=\"lm-cs-imgs\">\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u5b89\u88c51}}\" alt=\"\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u5b89\u88c52}}\" alt=\"\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u5b89\u88c53}}\" alt=\"\u6392\u6c14\u5b54\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u6392\u6c14\u5b54<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u5b89\u88c54}}\" alt=\"\u6392\u6c34\u6807\u51c6\u5165\u5730\u6f0f\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u6392\u6c34\u6807\u51c6\u5165\u5730\u6f0f<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u5b89\u88c55}}\" alt=\"\u6c2e\u6c14\u4fdd\u538b\u8868\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u6c2e\u6c14\u4fdd\u538b\u8868<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"{{\u56fe_\u5b89\u88c56}}\" alt=\"\u62bd\u771f\u7a7a\u4fdd\u538b\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u62bd\u771f\u7a7a\u4fdd\u538b<\/figcaption><\/figure>\n        <\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">05<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u8c03\u8bd5<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6ce8\u6c34\u6392\u6c14\u3001\u8054\u52a8\u903b\u8f91\u9a8c\u8bc1\u3001\u5404\u56de\u8def\u6d41\u91cf\u5747\u5300\u6027\u8c03\u8bd5\uff0c\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\u786e\u4fdd\u8fd0\u884c\u53c2\u6570\u8fbe\u6807\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5404\u623f\u95f4\u6e29\u5dee\u22642\u2103<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"{{\u56fe_\u8c03\u8bd5}}\" alt=\"\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">06<\/span><div class=\"lm-cs-title\">\u7ae3\u5de5\u9a8c\u6536<\/div><\/div>\n        <div class=\"lm-cs-body\">\u9690\u853d\u5de5\u7a0b\u5f71\u50cf\u5f52\u6863\uff0c\u9010\u9879\u9a8c\u6536\u7b7e\u5b57\uff0c\u4ea4\u4ed8\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u3002\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\u4f5c\u4e3a\u9a8c\u6536\u51ed\u8bc1\u5b58\u6863\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5f71\u50cf\u6863\u6848 + \u9a8c\u6536\u8bb0\u5f55 + \u4f7f\u7528\u624b\u518c<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"{{\u56fe_\u9a8c\u6536}}\" alt=\"\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">+1<\/span><div class=\"lm-cs-title\">\u4ea4\u4ed8\u6559\u5b66<\/div><\/div>\n        <div class=\"lm-cs-body\">\u4e00\u5bf9\u4e00\u73b0\u573a\u8bbe\u5907\u6559\u5b66\uff0c\u6559\u4f1a\u6e29\u63a7\u5668\u4f7f\u7528\u3001\u6a21\u5f0f\u5207\u6362\u3001\u7d27\u6025\u64cd\u4f5c\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5ba2\u6237\u80fd\u72ec\u7acb\u64cd\u4f5c<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"{{\u56fe_\u6559\u5b66}}\" alt=\"\u73b0\u573a\u8bbe\u5907\u6559\u5b66\" onerror=\"this.style.display='none'\"><figcaption class=\"lm-cap\">\u73b0\u573a\u8bbe\u5907\u6559\u5b66<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">+2<\/span><div class=\"lm-cs-title\">\u552e\u540e\u4fdd\u969c<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6bcf\u5e74\u91c7\u6696\u5b63\u56de\u8bbf\u91c7\u96c6\u6570\u636e\uff0c\u540c\u6237\u578b\u5bf9\u6807\u5206\u6790\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/div>\n      <\/div>\n    <\/div>\n    <button class=\"lm-car-arrow lm-prev\" onclick=\"lmCarGo(lmCarCur-1)\" aria-label=\"\u4e0a\u4e00\u6b65\">\u2039<\/button>\n    <button class=\"lm-car-arrow lm-next\" onclick=\"lmCarGo(lmCarCur+1)\" aria-label=\"\u4e0b\u4e00\u6b65\">\u203a<\/button>\n    <div class=\"lm-car-dots\" id=\"lmCarDots\"><\/div>\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u9690\u853d\u5de5\u7a0b\u53ef\u89c6\u5316<\/h3>\n  <div class=\"lm-highlight-blue\">\u6bcf\u4e2a\u65bd\u5de5\u73af\u8282\u62cd\u7167\u5b58\u6863\uff0c\u5f62\u6210\u5b8c\u6574\u7684\u65bd\u5de5\u5f71\u50cf\u6863\u6848\u3002{{\u5ba2\u6237\u59d3\u540d}}\u53ef\u901a\u8fc7\u624b\u673a\u968f\u65f6\u67e5\u770b\u5de5\u5730\u8fdb\u5ea6\u548c\u9690\u853d\u5de5\u7a0b\u5b9e\u51b5\uff0c\u505a\u5230\u201c\u770b\u4e0d\u89c1\u7684\u5730\u65b9\u4e5f\u653e\u5fc3\u201d\u3002<\/div>\n<\/section>\n\n<!-- ===== S4\u00b7\u900f\u660e\u62a5\u4ef7 ===== -->\n<section class=\"lm-section\" id=\"s4\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S4<\/span>\u900f\u660e\u62a5\u4ef7<\/div>\n\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u4e00\uff1a\u8212\u4eab\u4e00\u62d6\u56db + \u4e91\u51c0\u65b0\u98ce\uff08\u8d1f1F-\u8d1f2F\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u4ef7\u683c\u6765\u6e90\uff1a\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93V5.0 \uff5c \u8212\u4eab\u7cfb\u5217\u4eab8\u6298<\/p>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u6263<\/th><th>\u6298\u540e\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tbody data-render=\"\u62a5\u4ef7\u7cfb\u7edf\u4e00\"><\/tbody>\n  <\/table>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u4e8c\uff1a\u5c0a\u777f\u5168\u6548280 + \u6c34\u6a21\u5757 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff081F-4F\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u4ef7\u683c\u6765\u6e90\uff1a\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93V5.0 \uff5c \u5c0a\u777f\u5168\u6548\u4eab8.5\u6298 \uff5c \u6c34\u6a21\u5757\u4e0d\u6253\u6298<\/p>\n\n  <h4 style=\"margin:12px 0 6px;color:var(--lm-gold2);\">1. \u5ba4\u5916\u673a + \u6c34\u6a21\u5757<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u6263<\/th><th>\u6298\u540e\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tbody data-render=\"\u62a5\u4ef7\u4e3b\u673a\"><\/tbody>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">2. \u5ba4\u5185\u673a<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u533a\u57df<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>8.5\u6298<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tbody data-render=\"\u62a5\u4ef7\u5185\u673a\"><\/tbody>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">3. \u5730\u6696\u7cfb\u7edf<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7<\/th><th>\u9762\u79ef<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tbody data-render=\"\u62a5\u4ef7\u5730\u6696\"><\/tbody>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">4. \u6c47\u603b<\/h4>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:50%;\">\u9879\u76ee<\/th><th style=\"width:50%;\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n    <tbody data-render=\"\u62a5\u4ef7\u6c47\u603b\"><\/tbody>\n  <\/table>\n\n  <div class=\"lm-chart-box\">\n    <div class=\"lm-chart-title\">\u8bbe\u5907\u62a5\u4ef7\u6784\u6210\uff08\u5143\uff09<\/div>\n    <div class=\"lm-chart\" id=\"lmPriceChart\"><\/div>\n  <\/div>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u4ef7\u683c\u8bf4\u660e\uff1a<\/strong><br>\n    1. \u4ee5\u4e0a\u4ef7\u683c\u4e3a\u8bbe\u5907+\u5b89\u88c5\u8d39\u5408\u8ba1\uff0c\u6309\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee402 V5.0\u6267\u884c\uff1b<br>\n    2. \u8212\u4eab\u7cfb\u5217\u4eab8\u6298\u4f18\u60e0\uff0c\u5c0a\u777f\u5168\u6548\u7cfb\u5217\u4eab8.5\u6298\u4f18\u60e0\uff1b<br>\n    3. \u6c34\u6a21\u5757\u4e3a\u4e0d\u6253\u6298\u4ea7\u54c1\uff0c\u4ee5\u9762\u4ef7\u8ba1\uff1b<br>\n    4. \u4f4e\u6e29\u9664\u6e7f\u5305\u4e3a\u9009\u914d\u9879\uff0c\u4ef7\u683c\u5f85\u786e\u8ba4\u540e\u8ba1\u5165\u603b\u4ef7\uff1b<br>\n    5. \u5b89\u88c5\u8f85\u6750\u8be6\u89c1\u4e0b\u65b9\u8f85\u6750\u914d\u7f6e\u6e05\u5355\uff1b<br>\n    6. \u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a30\u5929\uff0c\u6700\u7ec8\u4ef7\u683c\u4ee5\u7b7e\u7ea6\u786e\u8ba4\u4e3a\u51c6\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355<\/h3>\n  <p style=\"color:var(--lm-text2);margin-bottom:12px;font-size:14px;\">\u4ee5\u4e0b\u8f85\u6750\u6e05\u5355\u6309\u6307\u4ee406 V2.0\u89c4\u8303\u8f93\u51fa\uff0c\u4ec5\u5217\u54c1\u724c\u89c4\u683c\uff0c\u4e0d\u542b\u4ef7\u683c\u3002\u70b9\u51fb\u5c55\u5f00\u67e5\u770b\u3002<\/p>\n\n  <div class=\"lm-acc\">\n    <div class=\"lm-acc-item lm-open\">\n      <div class=\"lm-acc-head\">\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u8212\u4eab\u7cfb\u5217\u00b7\u8d1f1F-\u8d1f2F\uff09<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1\uff0c\u8f93\u9001\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1\uff0c\u8f93\u9001\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><\/tr>\n          <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>12\u94dc\u7ba1\u53ca\u4ee5\u4e0b15mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>16\u94dc\u7ba1\u53ca\u4ee5\u4e0a20mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n          <tr><td>\u5b9a\u5236<\/td><td>\u540a\u5361\u4e0e\u652f\u67b6<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u67b6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u8def\u5b89\u88c5<\/td><\/tr>\n          <tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr>\n          <tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr>\n          <tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5\/\u8fd0\u8f93<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\/\u8fd0\u8f93<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6599\uff08\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u00b71F-4F\uff09<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <h4 style=\"margin:8px 0 6px;color:var(--lm-gold2);\">\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6599\u90e8\u5206<\/h4>\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><\/tr>\n          <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea615\/20mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\u4e3b\u7ba1\u90e8\u5206<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u4e3b\u7ba1<\/td><td>dn32*en2.9\/dn40*en3.7\/dn50*en4.6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u9009\u62e9<\/td><\/tr>\n          <tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u03c632*20\/\u03c640*20\/\u03c650*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29\uff0c\u51cf\u5c11\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c421\u4e2a<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u94dc\u8d28\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\uff0c\u5206\u8def\u63a7\u5236<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u4e00\u4f53\u89d2\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u65b9\u4fbf\u68c0\u4fee<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\/\u76f4\u63a5\/\u5f2f\u5934<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u5b89\u5168\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u6c34\u538b<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a<\/td><\/tr>\n          <tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u81ea\u52a8\u8865\u6c34\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u8bc1\u7cfb\u7edf\u6c34\u91cf\u5145\u8db3<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6b63\u53d1<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>40\u76ee<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fc7\u6ee4\u6742\u8d28<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\u5730\u9762\u90e8\u5206<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u6563\u5931<\/td><\/tr>\n          <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\u63a7\u5236\u90e8\u5206<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u65e5\u7acb<\/td><td>\u6c34\u6e29\u63a7\u5236\u5668<\/td><td>PC-WHM2Q\/PC-WHM3Q<\/td><td>1<\/td><td>\u8c03\u8282\u91c7\u6696\u6c34\u6e29<\/td><\/tr>\n          <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr>\n          <tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>2*1.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u63a7\u5236\u7ebf<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>PVC\u5957\u7ba1<\/td><td>\u03c616<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u65b0\u98ce\u7cfb\u7edf\u8f85\u6750<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u65e5\u7acb<\/td><td>\u4e91\u51c0\u65b0\u98ce<\/td><td>KPI-3521Q3A\/F 350m\u00b3\/h<\/td><td>1\u53f0<\/td><td>\u4e09\u6863\u8c03\u901f\/\u4e09\u79cd\u6362\u6c14\/\u667a\u80fd\u8054\u52a8<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>PE\u6ce2\u7eb9\u7ba1<\/td><td>\u03c6110\/\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u73af\u4fdd\u65e0\u83cc\/\u8010\u8150\u8680<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>\u4e3b\u673a\u8fde\u63a5\u7ba1<\/td><td>\u03c6110<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5bc6\u5c01\u9632\u5c18\/\u964d\u566a<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3<\/td><td>\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>ABS\u53ef\u8c03\u8282\u98ce\u53e3<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>\u9632\u96e8\u98ce\u7f69<\/td><td>\u03c6120<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>304\u4e0d\u9508\u94a2\u9632\u96e8<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u670d\u52a1\u4fdd\u969c<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1\/\u51fa\u56fe\/\u5b9a\u4f4d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d\u7b49<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4f1f\u661f\u5382\u5bb6\u7b2c\u4e09\u65b9\u76d1\u7406\uff0c\u542b\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr>\n          <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-highlight-blue\" style=\"margin:16px 0;font-size:13px;\">\n    <strong>\u8f85\u6750\u8bf4\u660e\uff1a<\/strong><br>\n    1. \u4ee5\u4e0a\u8f85\u6750\u5747\u4e3a\u9ed8\u8ba4\u89c4\u683c\uff0c\u54c1\u724c\u4e0d\u53ef\u66ff\u6362\uff0c\u89c4\u683c\u4e0d\u53ef\u865a\u6784\uff1b<br>\n    2. \u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6570\u91cf\u4ee5\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff1b<br>\n    3. \u8f85\u6750\u4e0d\u6d89\u53ca\u62a5\u4ef7\u91d1\u989d\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff1b<br>\n    4. \u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3001\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff1b<br>\n    5. \u5982\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u52a8\u7528\u540a\u88c5\u8bbe\u5907\uff0c\u8d39\u7528\u53e6\u8ba1\u3002\n  <\/div>\n\n  <!-- ===== 20\u5e74\u5168\u5468\u671f\u5bf9\u6bd4\u5206\u6790\u7ffb\u8f6c\u5361 ===== -->\n  <div class=\"lm-flip-card lm-flip-card-20y\" id=\"compare-20y\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\">\n        <div class=\"lm-flip-title\">20\u5e74\u5168\u5468\u671f\u6295\u5165\u5bf9\u6bd4 \u00b7 \u5806\u53e0\u67f1\u72b6\u56fe\uff08\u7d2f\u8ba1\u8d39\u7528\u00b7\u5143\uff09<\/div>\n        <div id=\"chart-20y\"><\/div>\n        <div class=\"lm-chart-fallback\">\ud83d\udcca \u6b64\u56fe\u8868\u9700\u542f\u7528 JavaScript \u67e5\u770b\uff1b20\u5e74\u603b\u8d26\u660e\u7ec6\u89c1\u80cc\u9762\u4e09\u5f20\u8868\u683c\u3002<\/div>\n        <div class=\"lm-flip-cap\">\u5dee\u989d\u7ed3\u8bba\uff1a{{20\u5e74\u5dee\u989d\u7ed3\u8bba}}<\/div>\n      <\/div>\n      <div class=\"lm-flip-back\">\n        <div class=\"lm-flip-tip\">\u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b20\u5e74\u53ef\u89c6\u5316\u56fe\u8868 \u21bb<\/div>\n        <div class=\"lm-flip-title\">20\u5e74\u5168\u5468\u671f\u603b\u8d26 \u00b7 \u660e\u7ec6\uff08\u7b97\u8d26\u7ef4\u5ea6\u9501\uff09<\/div>\n        <table class=\"lm-table\">\n          <tr><th>\u9879\u76ee<\/th><th>{{\u65b9\u6848A\u540d}}<\/th><th>{{\u65b9\u6848B\u540d}}<\/th><\/tr>\n          <tbody data-render=\"20\u5e74\u88681\"><\/tbody>\n        <\/table>\n        <table class=\"lm-table\">\n          <tr><th>\u9879\u76ee<\/th><th>\u5c0a\u777f\u5168\u6548<\/th><th>\u6c34\u5885\u9002<\/th><\/tr>\n          <tbody data-render=\"20\u5e74\u88682\"><\/tbody>\n        <\/table>\n        <table class=\"lm-table\">\n          <tr><th>\u9879\u76ee<\/th><th>\u5c0a\u777f\u5168\u6548<\/th><th>\u6c34\u5885\u9002<\/th><th>\u5dee\u989d\u7ed3\u8bba<\/th><\/tr>\n          <tbody data-render=\"20\u5e74\u88683\"><\/tbody>\n        <\/table>\n        <p style=\"font-size:12px;color:var(--lm-text2);margin-top:10px;\"><strong>\u7b97\u8d26\u7ef4\u5ea6\u9501\uff1a<\/strong>\u4f7f\u7528\u6210\u672c =\uff08\u8d2d\u7f6e + \u7ef4\u4fdd + \u7528\u8d39\uff09\u00f7 \u5bff\u547d\u5e74\u9650\u3002\u6570\u636e\u6765\u6e90\uff1aS4\u62a5\u4ef7\uff08\u6307\u4ee402\u00b7page_id=662\uff09\uff0f\u6210\u90fd\u6c14\u4ef73.4\u5143\u00b7\u7535\u4ef70.52\u5143\uff08\u4f30\u7b97\u00b7\u4ee5\u5b9e\u9645\u4e3a\u51c6\uff09\uff0f\u7ef4\u4fdd\u8d39800-1200\u5143\u00b7\u5e74\uff08\u767d\u76ae\u4e66\u00b7\u884c\u4e1a\u60ef\u4f8b\uff09\uff0f\u70ed\u6e90\u5bff\u547d15-20\u5e74\uff08\u4ea7\u54c1\u6807\u79f0+\u767d\u76ae\u4e66\uff09\u3002\u7f3a\u5931\u9879\u6807\u300c\u5f85\u786e\u8ba4\u00b7\u4ee5\u52d8\u6d4b\u5b9e\u6d4b\u4e3a\u51c6\u300d\u4e0d\u7f16\u9020\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== S5\u00b7\u6848\u4f8b\u9a8c\u8bc1 ===== -->\n<section class=\"lm-section\" id=\"s5\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S5<\/span>\u6848\u4f8b\u9a8c\u8bc1<\/div>\n\n  <table class=\"lm-table\">\n    <tr><th>\u6848\u4f8b<\/th><th>\u9762\u79ef<\/th><th>\u7cfb\u7edf\u914d\u7f6e<\/th><th>\u8fd0\u884c\u6570\u636e<\/th><th>\u53c2\u8003\u4ef7\u503c<\/th><\/tr>\n    <tbody data-render=\"\u6848\u4f8b\u8868\"><\/tbody>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u6848\u4f8b\u9a8c\u8bc1\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u6848\u4f8b\u5747\u53ef\u5728\u9f99\u8109\u6696\u901a\u5b98\u7f51\u6848\u4f8b\u5e93\uff08<a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">longmai-nt.com\/?page_id=2297<\/a>\uff09\u67e5\u8be2\u9a8c\u8bc1\u3002{{\u5ba2\u6237\u59d3\u540d}}\u9879\u76ee\u7684\u65b9\u6848\u6570\u636e\u4e5f\u5c06\u8131\u654f\u540e\u5165\u5e93\uff0c\u6210\u4e3a\u672a\u6765\u540c\u6237\u578b\u5ba2\u6237\u7684\u53c2\u8003\u6807\u6746\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u552e\u540e\u4fdd\u969c\u4e0e10\u5e74\u80fd\u6e90\u8ba1\u5212<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u8d28\u4fdd\u671f\u9650<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u6574\u673a\uff09<\/td><td>60\u4e2a\u6708<\/td><td>\u8bbe\u5907\u8fdb\u573a\u65e5\u8d77\u7b97\uff0c\u542b6\u4e2a\u6708\u88c5\u4fee\u671f<\/td><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u538b\u7f29\u673a\uff09<\/td><td>60\u4e2a\u6708<\/td><td>\u884c\u4e1a\u5185\u9886\u5148\u8d28\u4fdd\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u4f1f\u661f\u5730\u6696\u7ba1\u9053<\/td><td>50\u5e74<\/td><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd\u4e09\u65b9\u8054\u4fdd<\/td><\/tr>\n    <tr><td>\u9f99\u8109\u5b89\u88c5\u5de5\u7a0b<\/td><td>2\u5e74<\/td><td>\u9690\u853d\u5de5\u7a0b\u7ec8\u8eab\u8d1f\u8d23\u5236<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight-green\" style=\"margin:16px 0;\">\n    <strong>{{\u5ba2\u6237\u59d3\u540d}}\u5bb6\u52a0\u5165{{\u552e\u540e\u5206\u7ec4}}\uff0c\u4eab\u53d7\u4ee5\u4e0b\u670d\u52a1\uff1a<\/strong><br>\n    1. \u6bcf\u5e74\u91c7\u6696\u5b63\u540e\u4e3b\u52a8\u56de\u8bbf\uff0c\u91c7\u96c6\u80fd\u8017\u6570\u636e\uff1b<br>\n    2. \u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807\u5206\u6790\uff0c\u63d0\u4f9b\u8282\u80fd\u4f18\u5316\u5efa\u8bae\uff1b<br>\n    3. 10\u5e74\u5185\u82e5\u56e0\u8bbe\u8ba1\u6216\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u80fd\u8017\u5f02\u5e38\uff0c\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u8c03\u6574\uff1b<br>\n    4. \u6570\u636e\u8131\u654f\u540e\u533f\u540d\u4f7f\u7528\uff0c\u4fdd\u62a4\u5ba2\u6237\u9690\u79c1\uff1b<br>\n    5. \u552e\u540e\u95ee\u9898\u53cd\u9988\u81f3\u5ba2\u6237\u6863\u6848\uff0c\u53cd\u63a8\u65b9\u6848\u6807\u51c6\u66f4\u65b0\u3002\n  <\/div>\n\n  <table class=\"lm-table\">\n    <tr><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u54cd\u5e94\u6807\u51c6<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u7d27\u6025\u62a5\u4fee<\/td><td>24\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><td>\u7cfb\u7edf\u6545\u969c\u3001\u6f0f\u6c34\u3001\u4e0d\u5236\u51b7\/\u5236\u70ed\u7b49\u7d27\u6025\u95ee\u9898<\/td><\/tr>\n    <tr><td>\u5e38\u89c4\u7ef4\u4fdd<\/td><td>48\u5c0f\u65f6\u5185\u5b89\u6392<\/td><td>\u6ee4\u7f51\u6e05\u6d17\u3001\u7cfb\u7edf\u68c0\u67e5\u3001\u53c2\u6570\u8c03\u8bd5<\/td><\/tr>\n    <tr><td>\u5e74\u5ea6\u56de\u8bbf<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u540e<\/td><td>\u80fd\u8017\u6570\u636e\u91c7\u96c6+\u7cfb\u7edf\u5065\u5eb7\u68c0\u67e5+\u4f18\u5316\u5efa\u8bae<\/td><\/tr>\n    <tr><td>\u8fdc\u7a0b\u8bca\u65ad<\/td><td>\u5373\u65f6<\/td><td>\u901a\u8fc7AI\u96c6\u63a7\u5c4f\u8fdc\u7a0b\u8bfb\u53d6\u8fd0\u884c\u6570\u636e\uff0c\u5feb\u901f\u5b9a\u4f4d\u95ee\u9898<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u53cd\u9988\u673a\u5236\uff1a<\/strong>\u505a\u5b8c\u4e00\u4ef6\u4e8b\uff0c\u5fc5\u987b\u628a\u7ed3\u679c\u586b\u56de\u6765\u3002{{\u5ba2\u6237\u59d3\u540d}}\u9879\u76ee\u7684\u6240\u6709\u65bd\u5de5\u6570\u636e\u3001\u9a8c\u6536\u8bb0\u5f55\u3001\u80fd\u8017\u6570\u636e\u5747\u5f55\u5165\u5ba2\u6237\u6210\u529f\u6863\u6848\uff0c\u4f5c\u4e3a\u672a\u6765\u540c\u7c7b\u578b\u9879\u76ee\u7684\u53c2\u8003\u6807\u6746\u3002\u552e\u540e\u95ee\u9898\u53cd\u63a8\u81f3\u65b9\u6848\u6807\u51c6\uff0c\u6301\u7eed\u4f18\u5316\u77e5\u8bc6\u5e93\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== \u9644\u5f55\u00b7\u54c1\u724c\u6388\u6743 ===== -->\n<section class=\"lm-section\" id=\"sa\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">\u9644<\/span>\u54c1\u724c\u6388\u6743<\/div>\n  <p style=\"color:var(--lm-text2);margin-bottom:16px;\">\u9f99\u8109\u6696\u901a\u6301\u6709\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u8d44\u8d28\uff0c\u4ee5\u4e0b\u4e3a\u76f8\u5173\u6388\u6743\u8bc1\u4e66\u5b9e\u62cd\uff1a<\/p>\n  <div class=\"lm-img-row\">\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082024\uff09<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u8054\u7cfb\u6211\u4eec ===== -->\n<section class=\"lm-section lm-contact-footer\" id=\"s10\">\n  <div class=\"lm-cf-header\">\n    <div class=\"lm-cf-title\"><span class=\"lm-phone-icon\">\u260e<\/span>\u8054\u7cfb\u6211\u4eec<\/div>\n    <div class=\"lm-cf-sub\">\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u91cf\u623f\u5b9a\u5236\u7cfb\u7edf\u65b9\u6848 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5<\/div>\n  <\/div>\n\n  <div class=\"lm-cf-contacts\">\n    <a href=\"tel:028-86131795\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u5357\u5bcc\u68ee\u5e97<\/span><span class=\"lm-phone\">028-86131795<\/span><\/div>\n    <\/a>\n    <a href=\"tel:028-65272586\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u5317\u5bcc\u68ee\u5e97<\/span><span class=\"lm-phone\">028-65272586<\/span><\/div>\n    <\/a>\n    <a href=\"tel:028-61649321\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u552e\u540e\u4e13\u7ebf<\/span><span class=\"lm-phone\">028-61649321<\/span><\/div>\n    <\/a>\n    <a href=\"tel:13008113409\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u672c\u6848\u987e\u95ee{{\u987e\u95ee\u59d3\u540d}}<\/span><span class=\"lm-phone\">{{\u987e\u95ee\u7535\u8bdd}}<\/span><\/div>\n    <\/a>\n  <\/div>\n\n  <div class=\"lm-cf-services\">\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u4e0a\u95e8\u5b9e\u5730\u52d8\u6d4b<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u4e13\u5c5e\u6237\u578b\u65b9\u6848\u62a5\u4ef7<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>36\u9879\u65bd\u5de5\u8282\u70b9\u9a8c\u6536<\/div>\n  <\/div>\n\n  <div class=\"lm-cf-stores\">\n    <div class=\"lm-cf-store\">\n      <div class=\"lm-store-label\"><span class=\"lm-pin\">\u25c6<\/span>\u5357\u5bcc\u68ee\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u5e97\">\n      <div class=\"lm-store-addr\"><span class=\"lm-pin\">\u25c6<\/span>\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/div>\n    <\/div>\n    <div class=\"lm-cf-store\">\n      <div class=\"lm-store-label\"><span class=\"lm-pin\">\u25c6<\/span>\u5317\u5bcc\u68ee\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u5e97\">\n      <div class=\"lm-store-addr\"><span class=\"lm-pin\">\u25c6<\/span>\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u99865\u697cA5135\u53f7<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-cf-service-area\">\n    <span class=\"lm-label\">\u670d\u52a1\u8986\u76d6\u533a\u53bf\uff1a<\/span>\u65b0\u90fd \u00b7 \u53cc\u6d41 \u00b7 \u90eb\u90fd \u00b7 \u90eb\u57ce \u00b7 \u6b66\u4faf \u00b7 \u6210\u534e \u00b7 \u5f6d\u5dde \u00b7 \u9f99\u6cc9 \u00b7 \u6e29\u6c5f \u7b49\u5168\u5883\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u65bd\u5de5\n  <\/div>\n\n  <div class=\"lm-cf-cta\">\n    <a href=\"tel:13008113409\" class=\"lm-btn\">\u514d\u8d39\u9884\u7ea6\u52d8\u6d4b \u2192<\/a>\n  <\/div>\n\n  <div class=\"lm-cf-footer-note\">* \u5177\u4f53\u9700\u7528\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u5dee\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/div>\n<\/section>\n\n<\/div>\n\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/echarts@5.5.0\/dist\/echarts.min.js\"><\/script>\n<script>\n\/* ====================== \u6e32\u67d3\u5f15\u64ce\uff08\u56fa\u5b9a\u6846\u67b6\u00b7\u52ff\u6539\uff09 ====================== *\/\nconst P = window.PROJECT || {};\n\n\/* \u9012\u5f52\u66ff\u6362\u53cc\u82b1\u62ec\u53f7\u5360\u4f4d\u7b26\uff1a\u652f\u6301\u53d8\u91cf\u5d4c\u5957\uff08\u5982\u7efc\u5408\u7ed3\u8bba\u5185\u542b\u5ba2\u6237\u59d3\u540d\u5360\u4f4d\u7b26\uff09 *\/\nfunction rt(s){\n  if(typeof s !== 'string') return s;\n  return s.replace(\/\\{\\{(.+?)\\}\\}\/g, (m, k)=>{\n    const v = P[k];\n    return v === undefined ? m : rt(String(v));\n  });\n}\n\n\/* \u5355\u5143\u683c\u6e32\u67d3\uff1a\u5b57\u7b26\u4e32\u76f4\u63a5\u8f93\u51fa\uff08\u652f\u6301HTML\uff09\uff1b\u5bf9\u8c61\u652f\u6301 t\/c\/r\/cls\/html\/link *\/\nfunction cellHtml(c){\n  if(typeof c === 'string') return '<td>'+c+'<\/td>';\n  if(c && typeof c === 'object'){\n    let attr = '';\n    if(c.c) attr += ' colspan=\"'+c.c+'\"';\n    if(c.r) attr += ' rowspan=\"'+c.r+'\"';\n    if(c.cls) attr += ' class=\"'+c.cls+'\"';\n    let inner = c.html !== undefined ? c.html : (c.t !== undefined ? c.t : '');\n    if(c.link) inner = '<a class=\"lm-case-link\" href=\"'+c.link+'\" target=\"_blank\">'+inner+'<\/a>';\n    return '<td'+attr+'>'+inner+'<\/td>';\n  }\n  return '<td>'+c+'<\/td>';\n}\n\/* \u884c\u6e32\u67d3\uff1a\u884c\u9996\u4e3a \"__HL__\" \u5219\u8be5\u884c\u9ad8\u4eae *\/\nfunction rowHtml(row){\n  if(row[0] === '__HL__'){\n    return '<tr class=\"lm-row-hl\">'+row.slice(1).map(cellHtml).join('')+'<\/tr>';\n  }\n  return '<tr>'+row.map(cellHtml).join('')+'<\/tr>';\n}\n\n\/* \u52a8\u6001\u6e32\u67d3\uff1a\u8868\u683c(tbody[data-render]) \/ \u5361\u7247 \/ \u4ea7\u54c1\u5361 *\/\nfunction renderDynamic(){\n  document.querySelectorAll('[data-render]').forEach(el=>{\n    const name = el.getAttribute('data-render');\n    const arr = P[name];\n    if(!Array.isArray(arr)) return;\n    const type = el.getAttribute('data-type');\n    if(type === 'cards'){\n      el.innerHTML = arr.map(c=>`\n        <div class=\"lm-compare-card lm-recommend\">\n          <span class=\"lm-badge lm-badge-rec\">${c.badge}<\/span>\n          <h4>${c.title}<\/h4>\n          <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a${c.scope}<\/p>\n          <ul>${c.items.map(i=>`<li>${i}<\/li>`).join('')}<\/ul>\n        <\/div>`).join('');\n    } else if(type === 'products'){\n      el.innerHTML = arr.map(p=>`\n        <div class=\"lm-prod-card\">\n          <img decoding=\"async\" src=\"${p.img}\" alt=\"${p.title}\" onerror=\"this.style.display='none'\">\n          <div class=\"lm-pc-body\">\n            <div class=\"lm-pc-title\">${p.title}<\/div>\n            <div class=\"lm-pc-desc\">${p.desc}<\/div>\n            <a class=\"lm-pc-link\" href=\"${p.link}\" target=\"_blank\">\u67e5\u770b\u4ea7\u54c1\u624b\u518c \u2192<\/a>\n          <\/div>\n        <\/div>`).join('');\n    } else {\n      el.innerHTML = arr.map(rowHtml).join('');\n    }\n  });\n}\n\n\/* \u5168\u5c40 token \u66ff\u6362\uff08\u542b\u6807\u9898\/\u63cf\u8ff0\/\u6b63\u6587\/\u5df2\u6e32\u67d3\u8868\u683c\uff09 *\/\nfunction replaceAllTokens(){\n  document.title = rt(document.title);\n  document.querySelectorAll('meta[name=\"description\"]').forEach(m=>{ m.content = rt(m.content); });\n  document.body.innerHTML = rt(document.body.innerHTML);\n}\n\n\/* \u4ea4\u4e92\u7ed1\u5b9a\uff08\u5728 token \u66ff\u6362\u540e\u7ed1\u5b9a\u5230\u65b0 DOM\uff09 *\/\nfunction bindInteractions(){\n  \/\/ \u5bfc\u822a\u9ad8\u4eae\n  const lmTocItems = document.querySelectorAll('.lm-toc-item');\n  const lmSections = document.querySelectorAll('.lm-section');\n  function lmUpdateActive(){\n    const offset = 96; let activeId = 'cover';\n    lmTocItems.forEach(item=>{\n      const id = (item.getAttribute('href')||'').replace('#','');\n      const el = id && document.getElementById(id);\n      if(el && window.scrollY + offset >= el.getBoundingClientRect().top + window.scrollY){ activeId = id; }\n    });\n    lmTocItems.forEach(item=> item.classList.toggle('lm-active', (item.getAttribute('href')||'').replace('#','') === activeId));\n  }\n  window.addEventListener('scroll', lmUpdateActive); lmUpdateActive();\n\n  \/\/ Tabs\n  document.querySelectorAll('.lm-tab-btn').forEach(btn=>{\n    btn.addEventListener('click', ()=>{\n      const tab = btn.dataset.tab;\n      document.querySelectorAll('.lm-tab-btn').forEach(b=>b.classList.remove('lm-active'));\n      document.querySelectorAll('.lm-tab-panel').forEach(p=>p.classList.remove('lm-active'));\n      btn.classList.add('lm-active');\n      document.getElementById(tab).classList.add('lm-active');\n    });\n  });\n\n  \/\/ \u624b\u98ce\u7434\n  document.querySelectorAll('.lm-acc-head').forEach(head=>{\n    head.addEventListener('click', ()=> head.parentElement.classList.toggle('lm-open'));\n  });\n\n  \/\/ \u7ffb\u8f6c\u5361\n  document.querySelectorAll('.lm-flip-card').forEach(card=>{\n    card.addEventListener('click', ()=> card.classList.toggle('is-flipped'));\n  });\n\n  \/\/ \u8f6e\u64ad\n  const track = document.querySelector('#lmCraftCarousel .lm-carousel-track');\n  const slides = document.querySelectorAll('#lmCraftCarousel .lm-slide');\n  const dots = document.getElementById('lmCarDots');\n  let cur = 0; const cnt = slides.length;\n  slides.forEach((_, i)=>{\n    const d = document.createElement('span');\n    d.className = 'lm-dot' + (i===0?' lm-active':'');\n    d.addEventListener('click', ()=> go(i));\n    dots.appendChild(d);\n  });\n  window.lmCarGo = function(n){\n    cur = (n + cnt) % cnt;\n    track.style.transform = 'translateX(-' + (cur*100) + '%)';\n    document.querySelectorAll('#lmCarDots .lm-dot').forEach((d,i)=> d.classList.toggle('lm-active', i===cur));\n  };\n}\n\n\/* ECharts \u56fe\u8868\uff08\u6570\u636e\u5168\u90e8\u6765\u81ea PROJECT\uff09 *\/\nfunction renderCharts(){\n  if(!window.echarts) return;\n  const colors = ['#c89b3c','#e0b552','#b8860b','#8a6d2f'];\n\n  \/\/ \u62a5\u4ef7\u997c\u56fe\uff08\u81ea\u52a8\u53d6 \u62a5\u4ef7\u6c47\u603b \u524d4\u9879\uff09\n  const summary = (P['\u62a5\u4ef7\u6c47\u603b']||[]).filter(r=>r[0]!=='__HL__');\n  const pieData = summary.slice(0,4).map(r=>({ name:r[0], value: Number(String(r[1]).replace(\/[^\\d]\/g,'')), itemStyle:{ color: colors[summary.slice(0,4).indexOf(r)%4] } }));\n  const priceChart = echarts.init(document.getElementById('lmPriceChart'));\n  priceChart.setOption({\n    backgroundColor:'transparent',\n    tooltip:{ trigger:'item', formatter:'{b}: \u00a5{c} ({d}%)' },\n    legend:{ bottom:0, textStyle:{ color:'#5a4d38' } },\n    series:[{ type:'pie', radius:['38%','66%'], center:['50%','46%'], itemStyle:{borderColor:'#ffffff',borderWidth:2}, label:{color:'#3a3326',fontSize:12}, data:pieData }]\n  });\n\n  \/\/ \u516d\u7ef4\u96f7\u8fbe\n  const six = P['\u516d\u7ef4\u96f7\u8fbe'] || { A:[], B:[] };\n  const sixChart = echarts.init(document.getElementById('chart-six'));\n  sixChart.setOption({\n    backgroundColor:'transparent',\n    tooltip:{},\n    legend:{ data:['\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757','\u6c34\u5885\u9002'], top:0, textStyle:{ color:'#e8dcc0' } },\n    radar:{\n      center:['50%','56%'], radius:'66%',\n      indicator:[ {name:'\u521d\u6295\u8d44',max:100},{name:'\u8fd0\u884c\u8d39',max:100},{name:'\u8212\u9002\u5ea6',max:100},{name:'\u7a33\u5b9a\u6027',max:100},{name:'\u7ef4\u62a4\u8d39',max:100},{name:'\u5bff\u547d',max:100} ],\n      axisName:{ color:'#e8dcc0', fontSize:13 },\n      splitLine:{ lineStyle:{ color:'rgba(212,160,23,.25)' } },\n      splitArea:{ areaStyle:{ color:['rgba(255,255,255,.03)','rgba(255,255,255,.07)'] } },\n      axisLine:{ lineStyle:{ color:'rgba(212,160,23,.30)' } }\n    },\n    series:[{ type:'radar', data:[\n      { value:six.A, name:'\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757', itemStyle:{color:'#C9A24B'}, lineStyle:{color:'#C9A24B',width:2}, areaStyle:{color:'rgba(201,162,75,.35)'} },\n      { value:six.B, name:'\u6c34\u5885\u9002', itemStyle:{color:'#4A90D9'}, lineStyle:{color:'#4A90D9',width:2}, areaStyle:{color:'rgba(74,144,217,.30)'} }\n    ] }]\n  });\n\n  \/\/ 20\u5e74\u5806\u53e0\u67f1\n  const y = P['20\u5e74'] || {};\n  const yrs = Array.from({length:20},(_,i)=>i+1);\n  const zrBuy=y.\u8d2d\u7f6eA||0, zrRun=y.\u5e74\u8d39A||0, zrM=y.\u5bff\u547dA||0, zrRep=y.\u66f4\u6362A||0, zrRepY=y.\u5bff\u547dA||18;\n  const ssBuy=y.\u8d2d\u7f6eB||0, ssRun=y.\u5e74\u8d39B||0, ssM=y.\u5bff\u547dB||0, ssRep=y.\u66f4\u6362B||0, ssRepY=y.\u5bff\u547dB||18;\n  const zrBuyA=[],zrRunA=[],zrMaintA=[],zrRepA=[], ssBuyA=[],ssRunA=[],ssMaintA=[],ssRepA=[];\n  yrs.forEach(yr=>{\n    zrBuyA.push(zrBuy); zrRunA.push(zrRun*yr); zrMaintA.push(zrM*yr); zrRepA.push(yr>=zrRepY?zrRep:0);\n    ssBuyA.push(ssBuy); ssRunA.push(ssRun*yr); ssMaintA.push(ssM*yr); ssRepA.push(yr>=ssRepY?ssRep:0);\n  });\n  const twentyChart = echarts.init(document.getElementById('chart-20y'));\n  twentyChart.setOption({\n    backgroundColor:'transparent',\n    tooltip:{ trigger:'axis', axisPointer:{type:'shadow'},\n      formatter:function(ps){ let s=ps[0].axisValue+'\u5e74<br>'; ps.forEach(p=>{ if(p.value) s+=p.marker+p.seriesName+'\uff1a\u00a5'+p.value.toLocaleString()+'<br>'; }); return s; } },\n    legend:{ type:'scroll', top:0, textStyle:{color:'#e8dcc0'},\n      data:['\u5c0a\u777f\u00b7\u8d2d\u7f6e','\u5c0a\u777f\u00b7\u7528\u8d39','\u5c0a\u777f\u00b7\u7ef4\u4fdd','\u5c0a\u777f\u00b7\u66f4\u6362','\u6c34\u5885\u9002\u00b7\u8d2d\u7f6e','\u6c34\u5885\u9002\u00b7\u7528\u8d39','\u6c34\u5885\u9002\u00b7\u7ef4\u4fdd','\u6c34\u5885\u9002\u00b7\u66f4\u6362'] },\n    grid:{ left:78, right:20, top:52, bottom:40 },\n    xAxis:{ type:'category', data:yrs, name:'\u5e74\u4efd', axisLabel:{color:'#e8dcc0'}, axisLine:{lineStyle:{color:'rgba(212,160,23,.4)'}} },\n    yAxis:{ type:'value', name:'\u7d2f\u8ba1\u8d39\u7528(\u5143)', axisLabel:{color:'#e8dcc0'}, splitLine:{lineStyle:{color:'rgba(255,255,255,.08)'}} },\n    series:[\n      { name:'\u5c0a\u777f\u00b7\u8d2d\u7f6e', type:'bar', stack:'\u5c0a\u777f', data:zrBuyA, itemStyle:{color:'#C9A24B'} },\n      { name:'\u5c0a\u777f\u00b7\u7528\u8d39', type:'bar', stack:'\u5c0a\u777f', data:zrRunA, itemStyle:{color:'#d8b86a'} },\n      { name:'\u5c0a\u777f\u00b7\u7ef4\u4fdd', type:'bar', stack:'\u5c0a\u777f', data:zrMaintA, itemStyle:{color:'#b8893c'} },\n      { name:'\u5c0a\u777f\u00b7\u66f4\u6362', type:'bar', stack:'\u5c0a\u777f', data:zrRepA, itemStyle:{color:'#8a6d2f'},\n        markLine:{ silent:true, symbol:'none', lineStyle:{color:'#C9A24B',type:'dashed',width:1.5},\n          label:{formatter:'\u70ed\u6e90\u66f4\u6362\u00b7\u7b2c'+zrRepY+'\u5e74',color:'#e8dcc0',position:'insideEndTop',fontSize:11}, data:[{xAxis:zrRepY-0.5}] } },\n      { name:'\u6c34\u5885\u9002\u00b7\u8d2d\u7f6e', type:'bar', stack:'\u6c34\u5885\u9002', data:ssBuyA, itemStyle:{color:'#4A90D9'} },\n      { name:'\u6c34\u5885\u9002\u00b7\u7528\u8d39', type:'bar', stack:'\u6c34\u5885\u9002', data:ssRunA, itemStyle:{color:'#6fa8e0'} },\n      { name:'\u6c34\u5885\u9002\u00b7\u7ef4\u4fdd', type:'bar', stack:'\u6c34\u5885\u9002', data:ssMaintA, itemStyle:{color:'#3d7bc0'} },\n      { name:'\u6c34\u5885\u9002\u00b7\u66f4\u6362', type:'bar', stack:'\u6c34\u5885\u9002', data:ssRepA, itemStyle:{color:'#2f5f96'} }\n    ]\n  });\n\n  window.addEventListener('resize', ()=>{ priceChart.resize(); sixChart.resize(); twentyChart.resize(); });\n}\n\n\/* \u542f\u52a8 *\/\ndocument.addEventListener('DOMContentLoaded', ()=>{\n  renderDynamic();\n  replaceAllTokens();\n  bindInteractions();\n  renderCharts();\n});\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>{{\u5ba2\u6237\u59d3\u540d}}{{\u9879\u76ee\u7c7b\u578b}} \u00b7 \u5168 [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-7249","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=7249\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"{{\u5ba2\u6237\u59d3\u540d}}{{\u9879\u76ee\u7c7b\u578b}} \u00b7 \u5168 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=7249\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249\",\"name\":\"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\",\"datePublished\":\"2026-07-20T00:48:23+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\",\"width\":1240,\"height\":1754},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7249#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=7249","og_locale":"zh_CN","og_type":"article","og_title":"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248 - \u9f99\u8109\u6696\u901a","og_description":"{{\u5ba2\u6237\u59d3\u540d}}{{\u9879\u76ee\u7c7b\u578b}} \u00b7 \u5168 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=7249","og_site_name":"\u9f99\u8109\u6696\u901a","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=7249","url":"https:\/\/longmai-nt.com\/?page_id=7249","name":"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=7249#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=7249#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","datePublished":"2026-07-20T00:48:23+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=7249#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=7249"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=7249#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","width":1240,"height":1754},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=7249#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u6a21\u7248"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7249"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7249\/revisions"}],"predecessor-version":[{"id":7250,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7249\/revisions\/7250"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}