{"id":7454,"date":"2026-07-21T15:48:30","date_gmt":"2026-07-21T07:48:30","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=7454"},"modified":"2026-10-11T23:38:10","modified_gmt":"2026-10-11T15:38:10","slug":"%e8%91%a3%e5%85%88%e7%94%9f%e6%9a%96%e9%80%9a%e6%96%b9%e6%a1%88%e5%89%8d%e4%b9%a6-2","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=7454","title":{"rendered":"\u8463\u5148\u751f\u6696\u901a\u65b9\u6848\u524d\u4e66"},"content":{"rendered":"\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u897f\u6d3e\u5c11\u57ce\u00b7\u8463\u5148\u751f\u00b7\u5929\u6c1f\u5730\u6c34vs\u5929\u6c34\u5730\u6c34vs\u8212\u4eab\u6c1f\u673a \u7a7a\u8c03\u4e09\u65b9\u6848+\u5730\u6696\u4e09\u65b9\u6848 \u5bf9\u6bd4\u65b9\u6848\u4e66\",\n  \"author\": {\n    \"@type\": \"Person\",\n    \"name\": \"\u4f59\u7231\u82f1\",\n    \"jobTitle\": \"\u9f99\u8109\u6696\u901a\u65b9\u6848\u987e\u95ee\",\n    \"description\": \"\u4ece\u4e1a14\u5e74\uff082012\u5e74\u52a0\u5165\u9f99\u8109\u6696\u901a\uff09\uff0c\u4e13\u6ce8\u5927\u5e73\u5c42\u4e0e\u522b\u5885\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u8bbe\u8ba1\",\n    \"telephone\": \"13908183204\"\n  },\n  \"datePublished\": \"2026-07-19\",\n  \"dateModified\": \"2026-07-19\",\n  \"publisher\": { \"@id\": \"https:\/\/longmai-nt.com\/#organization\" },\n  \"about\": {\n    \"@type\": \"Thing\",\n    \"name\": \"\u6696\u901a\u7a7a\u8c03\u5730\u6696\u65b9\u6848\u8bbe\u8ba1\"\n  }\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"260\u33a1\u5927\u5e73\u5c42\u9009\u6c34\u673a\u8fd8\u662f\u6c1f\u673a\uff1f\u54ea\u4e2a\u66f4\u8212\u670d\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6838\u5fc3\u533a\u522b\u5728\u590f\u5929\u672b\u7aef\u2014\u2014\u6c34\u673a\u51fa\u98ce15-17\u2103\u67d4\u548c\u3001\u6c1f\u673a\u51fa\u98ce7-10\u2103\u751f\u51b7\u3002\u5bb6\u91cc\u6709\u5c0f\u5b69\u3001\u540c\u5f00\u7387\u9ad8\uff0c\u6c34\u673a\u4f53\u611f\u66f4\u8212\u9002\u3002\u5982\u679c\u6ce8\u91cd\u81ea\u6e05\u6d01\u548c\u6e29\u6e7f\u7cbe\u51c6\u63a7\u5236\uff0c\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\u4e5f\u662f\u597d\u9009\u62e9\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u65b9\u6848A\u8d85\u914d\u7387125.4%\u662f\u5426\u5b89\u5168\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u65e5\u7acb\u6807\u51c6\u8d85\u914d\u4e0a\u9650130%\u3002\u65b9\u6848A\u8d85\u914d\u7387125.4%\uff0c\u5728\u6807\u51c6\u4e0a\u9650\u4ee5\u5185\uff0c\u9009\u578b\u5408\u7406\u3002\u4e66\u623f\u9009\u752818\u578b\u5185\u673a\uff081.8kW\uff09\u5339\u914d11.62\u33a1\u9762\u79ef\u3002\u5e38\u4f4f4\u4eba\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u5b9e\u9645\u8fd0\u884c\u538b\u529b\u53ef\u63a7\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5730\u6696\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u8981\u752840\u7ba1\u800c\u4e0d\u662f25\u7ba1\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"170\u33a1\u4ee5\u4e0a\u5927\u6237\u578b\u5730\u6696\u9762\u79ef\u5927\uff0c25\u7ba1\u6d41\u91cf\u4e0d\u591f\uff0c\u9505\u7089\u53ea\u80fd\u9760\u63d0\u9ad8\u6c34\u6e29\u6765\u51d1\u2014\u2014\u51b7\u51dd\u7089\u53d8\u9ad8\u6e29\u70e7\uff0c\u8282\u80fd\u4f18\u52bf\u6ca1\u4e86\u300240\u4e3b\u7ba1\u786e\u4fdd\u8db3\u591f\u6d41\u91cf\uff0c\u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c\u624d\u8282\u80fd\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\u548c\u4f20\u7edf\u4e24\u7528\u7089\u6709\u4ec0\u4e48\u533a\u522b\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4f20\u7edf\u4e24\u7528\u7089\u4e00\u53f0\u673a\u5668\u517c\u987e\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\uff0c\u51ac\u5929\u6d17\u6fa1\u65f6\u5730\u6696\u6e29\u5ea6\u53ef\u80fd\u6ce2\u52a8\u3002\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\uff1a24kW\u9505\u7089\u4e13\u804c\u5e26\u5730\u6696+\u53a8\u623f\u70ed\u6c34\uff0c16L\u70ed\u6c34\u5668\u4e13\u804c\u7ba1\u536b\u751f\u95f4\u70ed\u6c34\uff0c\u91c7\u6696\u70ed\u6c34\u5b8c\u5168\u5206\u79bb\u4e92\u4e0d\u5e72\u6270\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u53a8\u623f\u7a7a\u8c03\u600e\u4e48\u89e3\u51b3\uff1f9.67\u33a1\u80fd\u88c5\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u65b9\u6848A\/B\u5747\u914d\u7f6eRCIS-22FSCN1QD\u53a8\u623f\u4e13\u7528\u5185\u673a\uff08\u4e00\u62d6\u591a\u7cfb\u7edf\u4e2d\u7684\u4e00\u53f0\uff09\uff0c\u9762\u4ef76,175\u5143\u3002\u53a8\u623f\u4e13\u7528\u673a\u9632\u6cb9\u6c61\u8bbe\u8ba1\uff0c\u5355\u72ec\u98ce\u9053\uff0c\u4e0d\u5f71\u54cd\u5176\u4ed6\u533a\u57df\u3002\u5982\u9884\u7b97\u7d27\u5f20\u4e5f\u53ef\u8003\u8651\u9001\u98ce\u53e3\u65b9\u6848\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u54ea\u4e2a\u7ef4\u62a4\u6210\u672c\u66f4\u9ad8\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5929\u6c1f\u5730\u6c34\uff08\u6c1f\u7cfb\u7edf\uff09\u7ef4\u62a4\u6210\u672c\u4f4e\uff0c\u5236\u51b7\u5242\u4e00\u822c5-8\u5e74\u4e0d\u9700\u8981\u8865\u52a0\uff0c\u5185\u673a\u6ee4\u7f51\u6e05\u6d17\u5373\u53ef\u3002\u5929\u6c34\u5730\u6c34\uff08\u5168\u6c34\u7cfb\u7edf\uff09\u9700\u8981\u5b9a\u671f\u68c0\u67e5\u6c34\u8d28\u3001\u6c34\u8fc7\u6ee4\u5668\u3001\u81a8\u80c0\u7f50\u538b\u529b\uff0c\u51ac\u5b63\u9700\u505a\u9632\u51bb\u4fdd\u62a4\uff0c\u5e74\u7ef4\u62a4\u8d39\u7ea6\u6bd4\u6c1f\u7cfb\u7edf\u9ad8300-500\u5143\u3002\u4f46\u6c34\u7cfb\u7edf\u590f\u5b63\u66f4\u8282\u80fd\uff0c\u957f\u671f\u80fd\u8017\u66f4\u4f4e\u3002\u8463\u5148\u751f260\u33a1\u5927\u5e73\u5c42\u5982\u679c\u540c\u5f00\u7387\u9ad8\uff0c\u5929\u6c34\u5730\u6c34\u7684\u8282\u80fd\u6536\u76ca\u53ef\u8986\u76d6\u7ef4\u62a4\u5dee\u4ef7\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"31\u697c\u9ad8\u5c42\u5916\u673a\u4f4d\u600e\u4e48\u9009\uff1f\u566a\u97f3\u548c\u6563\u70ed\u6709\u5f71\u54cd\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"31\u697c\u9ad8\u5c42\u9009\u5916\u673a\u4f4d\u8981\u5173\u6ce8\u4e09\u70b9\uff1a\u4e00\u662f\u907f\u5f00\u4e3b\u5367\u548c\u5973\u513f\u623f\u95f4\u65b9\u5411\u7684\u5899\u9762\uff0c\u51cf\u5c11\u4f4e\u9891\u5171\u632f\u566a\u97f3\u4f20\u5ba4\u5185\uff1b\u4e8c\u662f\u786e\u4fdd\u5916\u673a\u4f4d\u901a\u98ce\u6563\u70ed\u826f\u597d\uff0c\u907f\u514d\u590f\u5929\u9ad8\u6e29\u4fdd\u62a4\u505c\u673a\uff1b\u4e09\u662f\u5916\u673a\u4f4d\u5e94\u505a\u51cf\u9707\u57ab\u5904\u7406\uff08\u9f99\u8109\u6696\u901a\u6807\u914d\u6a61\u80f6\u51cf\u9707\u57ab+\u5f39\u7c27\u51cf\u9707\u5668\uff09\u3002\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u5916\u673a\u566a\u97f3\u4ec556dB(A)\uff0c31\u697c\u5b89\u88c5\u5728\u5185\u673a\u8fdc\u79bb\u5367\u5ba4\u4e00\u4fa7\uff0c\u5ba4\u5185\u5b9e\u6d4b\u566a\u97f3\u53ef\u63a7\u5236\u572835dB(A)\u4ee5\u4e0b\u3002\u65b9\u6848C\u6c34\u7cfb\u7edf\u5916\u673a\u66f4\u91cd\uff08\u7ea6120kg\uff09\uff0c\u5b89\u88c5\u524d\u9700\u786e\u8ba4\u5916\u673a\u4f4d\u627f\u91cd\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"260\u33a1\u5927\u5e73\u5c42\u6709\u5fc5\u8981\u88c5\u65b0\u98ce\u7cfb\u7edf\u5417\uff1f\u98ce\u91cf\u600e\u4e48\u9009\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"260\u33a1\u5927\u5e73\u5c42\u5bc6\u5c01\u6027\u597d\uff0c\u81ea\u7136\u901a\u98ce\u4e0d\u8db3\uff0c\u5efa\u8bae\u88c5\u65b0\u98ce\u3002\u6309\u5c42\u9ad82.8m\u8ba1\u7b97\uff0c\u5ba4\u5185\u4f53\u79ef\u7ea6728m\u00b3\uff0c\u6bcf\u5c0f\u65f6\u6362\u6c140.5-0.7\u6b21\u9700\u98ce\u91cf350-500m\u00b3\/h\u3002\u672c\u65b9\u6848\u63a8\u8350\u65e5\u7acb\u4e91\u51c0\u2161\uff08500m\u00b3\/h\uff09\u6216\u5929\u51c0Q5\uff08350m\u00b3\/h\uff09\uff0c\u53ef\u6839\u636e\u5e38\u4f4f\u4eba\u53e3\u548c\u5367\u5ba4\u6570\u91cf\u9009\u62e9\u3002\u88c5\u4e86\u65b0\u98ce\u540e\u53ef\u5173\u7a97\u964d\u566a\uff0c\u914d\u5408\u7a7a\u8c03\u9664\u6e7f\uff0c\u5927\u5e73\u5c42\u4f53\u611f\u63d0\u5347\u660e\u663e\u3002\u65b0\u98ce\u7ba1\u9053\u4e0e\u7a7a\u8c03\u7ba1\u9053\u540c\u671f\u65bd\u5de5\uff0c\u907f\u514d\u540e\u671f\u540a\u9876\u8fd4\u5de5\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"\u9f99\u8109\u6696\u901a\",\n      \"item\": \"https:\/\/longmai-nt.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"\u65b9\u6848\u4e2d\u5fc3\",\n      \"item\": \"https:\/\/longmai-nt.com\/?page_id=2705\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"\u897f\u6d3e\u5c11\u57ce\u00b7\u8463\u5148\u751f\u6696\u901a\u65b9\u6848\u524d\u4e66\",\n      \"item\": \"https:\/\/longmai-nt.com\/?page_id=2705\"\n    }\n  ]\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Organization\",\n  \"@id\": \"https:\/\/longmai-nt.com\/#organization\",\n  \"name\": \"\u9f99\u8109\u6696\u901a\",\n  \"url\": \"https:\/\/longmai-nt.com\",\n  \"description\": \"\u4e13\u6ce8\u5927\u5e73\u5c42\u4e0e\u522b\u5885\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u8bbe\u8ba1\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546\uff0c\u63d0\u4f9b\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e00\u4f53\u5316\u89e3\u51b3\u65b9\u6848\",\n  \"areaServed\": \"\u6210\u90fd\",\n  \"knowsAbout\": [\"\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\", \"\u5929\u6c34\u5730\u6c34\", \"\u5730\u6696\u7cfb\u7edf\", \"\u65e5\u7acb\u65b0\u98ce\", \"\u51b7\u51dd\u9505\u7089\"],\n  \"slogan\": \"\u4e13\u4e1a\u6696\u901a \u00b7 \u7cbe\u5de5\u4ea4\u4ed8 \u00b7 \u7ec8\u8eab\u670d\u52a1\"\n}\n<\/script>\n\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/chart.js@4.4.3\/dist\/chart.umd.min.js\"><\/script>\n<style>\n\/* ===== CSS Variables ===== *\/\n:root {\n  --primary: #1a3a5c;\n  --primary-light: #2c5282;\n  --primary-dark: #0f2438;\n  --accent: #c0392b;\n  --accent-light: #e74c3c;\n  --gold: #b8860b;\n  --gold-light: #d4a017;\n  --bg: #f7f8fa;\n  --bg-card: #ffffff;\n  --bg-soft: #edf2f7;\n  --text: #2d3748;\n  --text-light: #718096;\n  --text-muted: #a0aec0;\n  --border: #e2e8f0;\n  --border-strong: #cbd5e0;\n  --shadow: 0 2px 8px rgba(0,0,0,0.06);\n  --shadow-md: 0 4px 16px rgba(0,0,0,0.08);\n  --shadow-lg: 0 8px 24px rgba(0,0,0,0.12);\n  --radius: 8px;\n  --radius-lg: 12px;\n  --radius-xl: 16px;\n  --max-width: 1200px;\n}\n\n\/* ===== Reset & Base ===== *\/\n* { margin: 0; padding: 0; box-sizing: border-box; }\n\nbody {\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", \"PingFang SC\", \"Hiragino Sans GB\", \"Microsoft YaHei\", \"Helvetica Neue\", Arial, sans-serif;\n  background: var(--bg);\n  color: var(--text);\n  line-height: 1.75;\n  font-size: 15px;\n  -webkit-font-smoothing: antialiased;\n  -moz-osx-font-smoothing: grayscale;\n}\n\n\/* ===== Cover Header ===== *\/\nheader.cover {\n  position: relative;\n  min-height: 420px;\n  display: flex;\n  align-items: center;\n  justify-content: center;\n  overflow: hidden;\n  background-image: url(\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1.png\");\n  background-size: cover;\n  background-position: center;\n  background-repeat: no-repeat;\n}\n\nheader.cover::after {\n  content: \"\";\n  position: absolute;\n  bottom: 0; left: 0; right: 0;\n  height: 60px;\n  background: linear-gradient(to bottom, transparent, var(--bg));\n  pointer-events: none;\n}\n\n.cover-panel {\n  position: relative;\n  z-index: 2;\n  max-width: 720px;\n  width: 90%;\n  padding: 40px 44px;\n  background: rgba(8,16,28,0.3);\n  border: 1px solid rgba(255,255,255,0.34);\n  border-radius: var(--radius-xl);\n  box-shadow:\n    0 18px 50px rgba(0,0,0,0.4),\n    inset 0 1px 0 rgba(255,255,255,0.32),\n    inset 0 -3px 10px rgba(0,0,0,0.3);\n  text-shadow: 0 1px 6px rgba(0,0,0,0.75);\n}\n\n.cover-panel::before {\n  content: \"\";\n  position: absolute;\n  top: 0; left: 16px; right: 16px;\n  height: 1px;\n  background: linear-gradient(to right, transparent, rgba(255,255,255,0.6), transparent);\n  border-radius: 1px;\n  pointer-events: none;\n}\n\n.cover-panel h1 {\n  text-shadow: 0 2px 10px rgba(0,0,0,0.7);\n}\n\n.cover-tag {\n  display: inline-block;\n  font-size: 13px;\n  letter-spacing: 2px;\n  color: #fff;\n  border: 1px solid rgba(255,255,255,0.55);\n  border-radius: 20px;\n  padding: 4px 16px;\n  margin-bottom: 20px;\n  font-weight: 500;\n  text-shadow: 0 1px 4px rgba(0,0,0,0.6);\n}\n\n.cover-panel h1 {\n  font-size: 28px;\n  color: #fff;\n  line-height: 1.4;\n  margin-bottom: 12px;\n  font-weight: 700;\n  letter-spacing: 1px;\n}\n\n.cover-sub {\n  font-size: 15px;\n  color: #fff;\n  margin-bottom: 28px;\n  line-height: 1.6;\n}\n\n.cover-info {\n  display: grid;\n  grid-template-columns: repeat(2, 1fr);\n  gap: 12px 24px;\n}\n\n.cover-info-item {\n  display: flex;\n  align-items: baseline;\n  gap: 8px;\n}\n\n.cover-info-item .label {\n  font-size: 13px;\n  color: #fff;\n  white-space: nowrap;\n  flex-shrink: 0;\n}\n\n.cover-info-item .value {\n  font-size: 14px;\n  color: #fff;\n  font-weight: 500;\n}\n\n\/* ===== Breadcrumb ===== *\/\n.lm-breadcrumb {\n  background: var(--bg-soft);\n  border-bottom: 1px solid var(--border);\n  padding: 10px 20px;\n  font-size: 13px;\n  color: var(--text-light);\n}\n\n.lm-breadcrumb ol {\n  list-style: none;\n  margin: 0 auto;\n  padding: 0;\n  display: flex;\n  flex-wrap: wrap;\n  gap: 6px;\n  max-width: 1200px;\n}\n\n.lm-breadcrumb li:not(:last-child)::after {\n  content: \"\/\";\n  margin-left: 6px;\n  color: var(--border);\n}\n\n.lm-breadcrumb a {\n  color: var(--primary);\n  text-decoration: none;\n}\n\n.lm-breadcrumb a:hover {\n  text-decoration: underline;\n}\n\n\/* ===== Subnav\uff08\u4e3b\u76ee\u5f55 + \u6298\u53e0\u4e0b\u62c9\u5b50\u76ee\u5f55\uff09 ===== *\/\n.lm-subnav {\n  position: sticky;\n  top: 0;\n  z-index: 99;\n  background: var(--bg-card);\n  border-bottom: 1px solid var(--border);\n  padding: 10px 20px;\n  display: flex;\n  justify-content: center;\n  gap: 10px;\n  flex-wrap: wrap;\n  box-shadow: 0 1px 4px rgba(0,0,0,0.04);\n}\n\n\/* \u4e3b\u76ee\u5f55\u6309\u94ae & \u76f4\u94fe *\/\n.lm-nav-toggle,\n.lm-nav-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 5px;\n  color: var(--text-light);\n  text-decoration: none;\n  font-size: 12px;\n  padding: 6px 12px;\n  border-radius: 4px;\n  border: 1px solid var(--border);\n  background: transparent;\n  font-family: inherit;\n  cursor: pointer;\n  transition: all 0.2s;\n  white-space: nowrap;\n}\n\n.lm-nav-toggle:hover,\n.lm-nav-link:hover {\n  color: var(--primary);\n  background: var(--bg-soft);\n  border-color: var(--primary);\n}\n\n.lm-nav-toggle[aria-expanded=\"true\"] {\n  color: var(--primary);\n  background: var(--bg-soft);\n  border-color: var(--primary);\n}\n\n.lm-caret {\n  font-size: 9px;\n  line-height: 1;\n  transition: transform 0.2s ease;\n}\n\n.lm-nav-toggle[aria-expanded=\"true\"] .lm-caret {\n  transform: rotate(180deg);\n}\n\n\/* \u4e0b\u62c9\u5b50\u76ee\u5f55\u9762\u677f *\/\n.lm-nav-item {\n  position: relative;\n}\n\n.lm-nav-panel {\n  display: none;\n  position: absolute;\n  top: calc(100% + 6px);\n  left: 0;\n  min-width: 150px;\n  max-height: 70vh;\n  overflow-y: auto;\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: 8px;\n  box-shadow: 0 10px 30px rgba(0,0,0,0.14);\n  padding: 6px;\n  z-index: 100;\n  flex-direction: column;\n}\n\n.lm-nav-panel.open {\n  display: flex;\n}\n\n.lm-nav-panel a {\n  color: var(--text-light);\n  text-decoration: none;\n  font-size: 12px;\n  padding: 7px 10px;\n  border-radius: 4px;\n  transition: all 0.2s;\n  white-space: nowrap;\n}\n\n.lm-nav-panel a:hover {\n  color: var(--primary);\n  background: var(--bg-soft);\n}\n\n\/* ===== Main Content ===== *\/\n.lm-wrap {\n  max-width: var(--max-width);\n  margin: 0 auto;\n  padding: 32px 20px 60px;\n}\n\nsection {\n  margin-bottom: 48px;\n  scroll-margin-top: 100px;\n}\n\nsection > h2 {\n  font-size: 22px;\n  color: var(--primary);\n  margin-bottom: 24px;\n  padding-bottom: 12px;\n  border-bottom: 2px solid var(--primary);\n  display: flex;\n  align-items: center;\n  gap: 10px;\n}\n\nsection > h2::before {\n  content: \"\";\n  display: inline-block;\n  width: 6px;\n  height: 24px;\n  background: var(--gold);\n  border-radius: 3px;\n}\n\nh3 {\n  font-size: 17px;\n  color: var(--primary);\n  margin: 28px 0 14px;\n  font-weight: 600;\n}\n\nh4 {\n  font-size: 15px;\n  color: var(--text);\n  margin: 20px 0 10px;\n  font-weight: 600;\n}\n\np {\n  margin-bottom: 12px;\n  color: var(--text);\n}\n\nul, ol {\n  margin: 10px 0 14px 20px;\n}\n\nli {\n  margin-bottom: 6px;\n  line-height: 1.7;\n}\n\na {\n  color: var(--primary-light);\n  text-decoration: none;\n  transition: color 0.2s;\n}\n\na:hover {\n  color: var(--accent);\n}\n\n\/* ===== Cards ===== *\/\n.lm-card {\n  background: var(--bg-card);\n  border-radius: var(--radius-lg);\n  padding: 24px;\n  box-shadow: var(--shadow);\n  margin-bottom: 20px;\n  border: 1px solid var(--border);\n}\n\n.lm-geo-card {\n  background: var(--bg-card);\n  border-radius: var(--radius-lg);\n  padding: 20px 24px;\n  box-shadow: var(--shadow);\n  margin-bottom: 16px;\n  border-left: 4px solid var(--primary);\n  transition: box-shadow 0.2s;\n}\n\n.lm-geo-card:hover {\n  box-shadow: var(--shadow-md);\n}\n\n\/* ===== Info Card ===== *\/\n.lm-info-card {\n  background: linear-gradient(135deg, #fff 0%, var(--bg-soft) 100%);\n  border-radius: var(--radius-lg);\n  padding: 28px;\n  margin-bottom: 24px;\n  border: 1px solid var(--border);\n  box-shadow: var(--shadow);\n}\n\n.lm-info-card h3 {\n  margin-top: 0;\n}\n\n.lm-kv {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(200px, 1fr));\n  gap: 10px 20px;\n  margin: 16px 0;\n}\n\n.lm-kv-item {\n  display: flex;\n  align-items: baseline;\n  gap: 8px;\n}\n\n.lm-kv-item .k {\n  font-size: 13px;\n  color: var(--text-light);\n  white-space: nowrap;\n}\n\n.lm-kv-item .v {\n  font-size: 14px;\n  color: var(--text);\n  font-weight: 500;\n}\n\n\/* ===== Flip Card ===== *\/\n.lm-flip-card {\n  perspective: 1000px;\n  cursor: pointer;\n  margin-bottom: 24px;\n}\n\n.lm-flip-inner {\n  position: relative;\n  width: 100%;\n  min-height: 360px;\n  transition: transform 0.6s;\n  transform-style: preserve-3d;\n}\n\n#customerCard .lm-flip-inner {\n  min-height: 800px;\n}\n\n.lm-flip-card.flipped .lm-flip-inner {\n  transform: rotateY(180deg);\n}\n\n.lm-flip-front,\n.lm-flip-back {\n  position: absolute;\n  top: 0; left: 0;\n  width: 100%;\n  height: 100%;\n  backface-visibility: hidden;\n  -webkit-backface-visibility: hidden;\n  border-radius: var(--radius-lg);\n  box-shadow: var(--shadow);\n  overflow: hidden;\n}\n\n.lm-flip-front {\n  background: linear-gradient(135deg, #fff 0%, var(--bg-soft) 100%);\n  border: 1px solid var(--border);\n  z-index: 2;\n}\n\n.lm-flip-back {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  transform: rotateY(180deg);\n  padding: 24px;\n  overflow-y: auto;\n}\n\n.lm-flip-hint {\n  display: inline-flex;\n  align-items: center;\n  gap: 6px;\n  font-size: 12px;\n  color: var(--text-light);\n  margin-top: 10px;\n}\n\n\/* ===== \u51b7\u8d1f\u8377\u5206\u6790 \u7ffb\u8f6c\u5361\uff08\u6b63\u9762\u8bbe\u8ba1\u56fe \/ \u80cc\u9762\u8d1f\u8377\u8868\uff09 ===== *\/\n.lm-load-flip .lm-flip-inner {\n  min-height: 540px;\n}\n.lm-load-front {\n  background: #0e1b2a;\n  padding: 0;\n}\n.lm-load-front img {\n  position: absolute;\n  top: 0; left: 0;\n  width: 100%;\n  height: 100%;\n  object-fit: cover;\n  object-position: center;\n}\n.lm-load-cap {\n  position: absolute;\n  left: 0; right: 0; bottom: 0;\n  z-index: 2;\n  padding: 18px 20px 16px;\n  background: linear-gradient(to top, rgba(0,0,0,0.72), rgba(0,0,0,0));\n  color: #fff;\n  font-size: 14px;\n  font-weight: 600;\n}\n.lm-load-cap span {\n  display: block;\n  margin-top: 6px;\n  font-size: 12px;\n  font-weight: 400;\n  color: var(--gold-light);\n}\n\n\/* ===== Fresh Air Flip Cards ===== *\/\n.lm-freshair-grid {\n  display: grid;\n  grid-template-columns: repeat(2, 1fr);\n  gap: 20px;\n  margin: 20px 0;\n}\n\n.lm-freshair-grid .lm-flip-card {\n  margin-bottom: 0;\n}\n\n.lm-freshair-grid .lm-flip-inner {\n  min-height: 440px;\n}\n\n.lm-freshair-front-img {\n  width: 100%;\n  height: 260px;\n  object-fit: contain;\n  background: #fff;\n  border-bottom: 1px solid var(--border);\n  display: block;\n  padding: 12px;\n}\n\n.lm-freshair-front-body {\n  padding: 20px;\n  text-align: center;\n}\n\n.lm-freshair-front-body h4 {\n  margin: 0 0 6px;\n  font-size: 18px;\n  color: var(--primary);\n}\n\n.lm-freshair-front-body .model {\n  font-size: 14px;\n  color: var(--text-light);\n  margin-bottom: 12px;\n}\n\n.lm-freshair-front-body .price {\n  font-size: 22px;\n  color: var(--accent);\n  font-weight: 700;\n  margin-bottom: 12px;\n}\n\n.lm-freshair-front-body .detail-link {\n  display: inline-block;\n  font-size: 13px;\n  color: var(--primary-light);\n  text-decoration: none;\n  margin-bottom: 8px;\n}\n\n.lm-freshair-front-body .detail-link:hover {\n  color: var(--accent);\n}\n\n.lm-freshair-front-body .hint {\n  font-size: 12px;\n  color: var(--text-light);\n}\n\n.lm-freshair-back h4 {\n  margin: 0 0 14px;\n  font-size: 16px;\n  color: var(--primary);\n  text-align: center;\n}\n\n.lm-freshair-back table {\n  font-size: 13px;\n  margin: 0;\n}\n\n.lm-freshair-back th,\n.lm-freshair-back td {\n  padding: 8px 10px;\n}\n\n@media (max-width: 640px) {\n  .lm-freshair-grid {\n    grid-template-columns: 1fr;\n  }\n  .lm-freshair-grid .lm-flip-inner {\n    min-height: 400px;\n  }\n}\n\n\/* ===== Cert Horizontal Scroll ===== *\/\n.lm-cert-strip {\n  display: flex;\n  flex-wrap: nowrap;\n  gap: 16px;\n  overflow-x: auto;\n  scroll-snap-type: x mandatory;\n  padding: 4px 4px 16px;\n  margin: 16px 0;\n}\n\n.lm-cert-strip-item {\n  flex: 0 0 220px;\n  scroll-snap-align: start;\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 12px;\n  box-shadow: var(--shadow);\n  text-align: center;\n}\n\n.lm-cert-strip-item img {\n  width: 100%;\n  aspect-ratio: 3 \/ 4;\n  object-fit: contain;\n  border-radius: var(--radius);\n  display: block;\n  background: #fff;\n  padding: 4px;\n}\n\n.lm-cert-strip-item figcaption {\n  font-size: 12px;\n  color: var(--text-light);\n  margin-top: 10px;\n  line-height: 1.5;\n}\n\n\/* ===== Service Promise Grid ===== *\/\n.lm-promise-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 16px;\n  margin: 16px 0 24px;\n}\n\n.lm-promise-card {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 20px;\n  box-shadow: var(--shadow);\n  transition: box-shadow 0.2s, transform 0.2s;\n}\n\n.lm-promise-card:hover {\n  box-shadow: var(--shadow-md);\n  transform: translateY(-2px);\n}\n\n.lm-promise-card h4 {\n  margin: 0 0 8px;\n  font-size: 15px;\n  color: var(--accent);\n}\n\n.lm-promise-card p {\n  margin: 0;\n  font-size: 13px;\n  color: var(--text-light);\n  line-height: 1.7;\n}\n\n\/* ===== Pain Point Visualization ===== *\/\n.lm-pain-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(220px, 1fr));\n  gap: 16px;\n  margin: 16px 0 24px;\n}\n\n.lm-pain-card {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 20px;\n  box-shadow: var(--shadow);\n  position: relative;\n  overflow: hidden;\n}\n\n.lm-pain-card::before {\n  content: \"\";\n  position: absolute;\n  top: 0; left: 0;\n  width: 4px;\n  height: 100%;\n}\n\n.lm-pain-card.core::before { background: var(--accent); }\n.lm-pain-card.important::before { background: var(--gold); }\n.lm-pain-card.normal::before { background: var(--primary); }\n\n.lm-pain-icon {\n  width: 44px;\n  height: 44px;\n  border-radius: 50%;\n  display: flex;\n  align-items: center;\n  justify-content: center;\n  font-size: 20px;\n  margin-bottom: 12px;\n  background: var(--bg-soft);\n}\n\n.lm-pain-card.core .lm-pain-icon { background: rgba(192,57,43,0.1); }\n.lm-pain-card.important .lm-pain-icon { background: rgba(184,134,11,0.1); }\n.lm-pain-card.normal .lm-pain-icon { background: rgba(21,101,192,0.1); }\n\n.lm-pain-card h4 {\n  margin: 0 0 8px;\n  font-size: 15px;\n  color: var(--text-main);\n}\n\n.lm-pain-card .tag {\n  display: inline-block;\n  font-size: 11px;\n  padding: 2px 8px;\n  border-radius: 999px;\n  margin-bottom: 10px;\n  font-weight: 600;\n}\n\n.lm-pain-card.core .tag { background: rgba(192,57,43,0.1); color: var(--accent); }\n.lm-pain-card.important .tag { background: rgba(184,134,11,0.1); color: var(--gold); }\n.lm-pain-card.normal .tag { background: rgba(21,101,192,0.1); color: var(--primary); }\n\n.lm-pain-card p {\n  margin: 0 0 8px;\n  font-size: 13px;\n  color: var(--text-light);\n  line-height: 1.6;\n}\n\n.lm-pain-card .solution {\n  margin-top: 10px;\n  padding-top: 10px;\n  border-top: 1px dashed var(--border);\n  font-size: 12px;\n  color: var(--text);\n}\n\n.lm-pain-card .solution strong {\n  color: var(--accent);\n}\n\n\/* ===== Tables ===== *\/\ntable {\n  width: 100%;\n  border-collapse: collapse;\n  margin: 14px 0 20px;\n  font-size: 13px;\n  background: var(--bg-card);\n  border-radius: var(--radius);\n  overflow: hidden;\n  box-shadow: var(--shadow);\n}\n\nth {\n  background: var(--primary);\n  color: #fff;\n  font-weight: 600;\n  padding: 10px 12px;\n  text-align: left;\n  font-size: 13px;\n  white-space: nowrap;\n}\n\ntd {\n  padding: 9px 12px;\n  border-bottom: 1px solid var(--border);\n  color: var(--text);\n}\n\ntr:nth-child(even) td {\n  background: var(--bg-soft);\n}\n\ntr:hover td {\n  background: #e6eff7;\n}\n\n.lm-total-row td {\n  background: var(--primary) !important;\n  color: #fff !important;\n  font-weight: 700;\n  font-size: 14px;\n}\n\n.lm-total-row td:first-child {\n  border-radius: 0;\n}\n\n\/* ===== Pills & Tags ===== *\/\n.lm-pill {\n  display: inline-block;\n  padding: 2px 10px;\n  border-radius: 12px;\n  font-size: 12px;\n  font-weight: 500;\n  margin: 0 2px;\n}\n\n.lm-pill-blue { background: #ebf4ff; color: #2b6cb0; }\n.lm-pill-red { background: #fff5f5; color: #c0392b; }\n.lm-pill-green { background: #f0fff4; color: #276749; }\n.lm-pill-gold { background: #fffbeb; color: #975a16; }\n.lm-pill-gray { background: var(--bg-soft); color: var(--text-light); }\n\n.lm-scheme-tag {\n  display: inline-block;\n  padding: 4px 14px;\n  border-radius: 4px;\n  font-size: 13px;\n  font-weight: 600;\n  margin-bottom: 10px;\n}\n\n.lm-tag-a { background: var(--primary); color: #fff; }\n.lm-tag-b { background: var(--accent); color: #fff; }\n.lm-tag-f { background: var(--gold); color: #fff; }\n\n.lm-badge {\n  display: inline-flex;\n  align-items: center;\n  gap: 4px;\n  padding: 3px 10px;\n  border-radius: 4px;\n  font-size: 12px;\n  font-weight: 600;\n}\n\n.lm-badge-warn { background: #fff3cd; color: #856404; border: 1px solid #ffeaa7; }\n.lm-badge-ok { background: #d4edda; color: #155724; border: 1px solid #c3e6cb; }\n.lm-badge-info { background: #d1ecf1; color: #0c5460; border: 1px solid #bee5eb; }\n.lm-badge-danger { background: #f8d7da; color: #721c24; border: 1px solid #f5c6cb; }\n\n\/* ===== Warning & OK Lines ===== *\/\n.lm-warn-line {\n  background: #fff3cd;\n  border-left: 4px solid var(--gold);\n  padding: 14px 20px;\n  border-radius: var(--radius);\n  margin: 16px 0;\n  font-size: 14px;\n  color: #856404;\n}\n\n.lm-warn-line strong {\n  color: #533f03;\n}\n\n.lm-ok-line {\n  background: #d4edda;\n  border-left: 4px solid #28a745;\n  padding: 14px 20px;\n  border-radius: var(--radius);\n  margin: 16px 0;\n  font-size: 14px;\n  color: #155724;\n}\n\n.lm-ok-line strong {\n  color: #0b3618;\n}\n\n\/* ===== Scheme Card (pcard) ===== *\/\n.lm-pcard {\n  background: var(--bg-card);\n  border-radius: var(--radius-lg);\n  padding: 28px;\n  margin-bottom: 28px;\n  box-shadow: var(--shadow-md);\n  border: 1px solid var(--border);\n  overflow: hidden;\n}\n\n.lm-pcard h3 {\n  margin-top: 0;\n  padding-bottom: 10px;\n  border-bottom: 1px solid var(--border);\n}\n\n.lm-pcard .lm-pcard-summary {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 16px 0 20px;\n}\n\n.lm-pcard .lm-pcard-summary .lm-badge {\n  font-size: 13px;\n  padding: 5px 14px;\n}\n\n\/* ===== Two Column ===== *\/\n.lm-two-col {\n  display: grid;\n  grid-template-columns: 1fr 1fr;\n  gap: 20px;\n  margin: 16px 0;\n}\n\n.lm-two-col > div {\n  background: var(--bg-card);\n  border-radius: var(--radius);\n  padding: 20px;\n  border: 1px solid var(--border);\n}\n\n.lm-two-col h4 {\n  margin-top: 0;\n  color: var(--primary);\n}\n\n\/* ===== Stars ===== *\/\n.lm-stars {\n  color: var(--gold);\n  letter-spacing: 2px;\n  font-size: 14px;\n}\n\n\/* ===== Chart Box ===== *\/\n.lm-chart-box {\n  background: var(--bg-card);\n  border-radius: var(--radius-lg);\n  padding: 20px;\n  margin: 16px 0;\n  border: 1px solid var(--border);\n}\n\n.lm-bar-row {\n  display: flex;\n  align-items: center;\n  gap: 10px;\n  margin: 8px 0;\n}\n\n.lm-bar-label {\n  width: 100px;\n  font-size: 13px;\n  color: var(--text-light);\n  flex-shrink: 0;\n  text-align: right;\n}\n\n.lm-bar-track {\n  flex: 1;\n  height: 24px;\n  background: var(--bg-soft);\n  border-radius: 4px;\n  overflow: hidden;\n  position: relative;\n}\n\n.lm-bar-fill {\n  height: 100%;\n  border-radius: 4px;\n  display: flex;\n  align-items: center;\n  justify-content: flex-end;\n  padding-right: 8px;\n  font-size: 12px;\n  color: #fff;\n  font-weight: 600;\n  transition: width 0.6s ease;\n}\n\n.lm-bar-fill.fill-primary { background: var(--primary); }\n.lm-bar-fill.fill-accent { background: var(--accent); }\n.lm-bar-fill.fill-gold { background: var(--gold); }\n.lm-bar-fill.fill-green { background: #28a745; }\n\n\/* ===== FAQ ===== *\/\n.lm-faq-item {\n  background: var(--bg-card);\n  border-radius: var(--radius);\n  margin-bottom: 12px;\n  border: 1px solid var(--border);\n  overflow: hidden;\n}\n\n.lm-faq-q {\n  padding: 16px 20px;\n  font-size: 15px;\n  font-weight: 600;\n  color: var(--primary);\n  cursor: pointer;\n  display: flex;\n  align-items: flex-start;\n  gap: 10px;\n  background: var(--bg-soft);\n  user-select: none;\n  position: relative;\n  padding-right: 44px;\n}\n\n.lm-faq-q::after {\n  content: \"\u25bc\";\n  position: absolute;\n  right: 18px;\n  top: 50%;\n  transform: translateY(-50%);\n  font-size: 12px;\n  color: var(--text-light);\n  transition: transform 0.25s ease;\n}\n\n.lm-faq-item.active .lm-faq-q::after {\n  transform: translateY(-50%) rotate(180deg);\n}\n\n.lm-faq-q::before {\n  content: \"Q\";\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  width: 24px;\n  height: 24px;\n  background: var(--primary);\n  color: #fff;\n  border-radius: 50%;\n  font-size: 12px;\n  font-weight: 700;\n  flex-shrink: 0;\n}\n\n.lm-faq-a {\n  padding: 0 20px 0 54px;\n  font-size: 14px;\n  color: var(--text);\n  line-height: 1.8;\n  max-height: 0;\n  opacity: 0;\n  overflow: hidden;\n  transition: max-height 0.35s ease, opacity 0.25s ease, padding 0.35s ease;\n}\n\n.lm-faq-item.active .lm-faq-a {\n  padding: 16px 20px 16px 54px;\n  max-height: 600px;\n  opacity: 1;\n}\n\n.lm-faq-a::before {\n  content: \"A\";\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  width: 24px;\n  height: 24px;\n  background: var(--accent);\n  color: #fff;\n  border-radius: 50%;\n  font-size: 12px;\n  font-weight: 700;\n  margin-left: -34px;\n  margin-right: 10px;\n  vertical-align: middle;\n}\n\n\/* ===== Links ===== *\/\n.lm-links {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(240px, 1fr));\n  gap: 12px;\n  margin: 16px 0;\n}\n\n.lm-links a {\n  display: block;\n  padding: 14px 18px;\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius);\n  font-size: 14px;\n  color: var(--primary);\n  transition: all 0.2s;\n}\n\n.lm-links a:hover {\n  border-color: var(--primary);\n  box-shadow: var(--shadow-md);\n  transform: translateY(-1px);\n}\n\n.lm-intlink {\n  color: var(--primary);\n  text-decoration: underline;\n  text-decoration-color: var(--gold);\n  text-underline-offset: 2px;\n  font-weight: 500;\n}\n\n.lm-intlink:hover {\n  color: var(--accent);\n}\n\n\/* ===== Cert Grid ===== *\/\n.lm-cert-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(180px, 1fr));\n  gap: 12px;\n  margin: 16px 0;\n}\n\n.lm-cert-grid .lm-cert-item {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius);\n  padding: 14px 16px;\n  text-align: center;\n}\n\n.lm-cert-grid .lm-cert-item .cert-name {\n  font-size: 14px;\n  font-weight: 600;\n  color: var(--primary);\n  margin-bottom: 4px;\n}\n\n.lm-cert-grid .lm-cert-item .cert-desc {\n  font-size: 12px;\n  color: var(--text-light);\n}\n\n\/* ===== Store Grid ===== *\/\n.lm-store-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(220px, 1fr));\n  gap: 12px;\n  margin: 16px 0;\n}\n\n.lm-store-grid .lm-store-item {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius);\n  padding: 16px;\n}\n\n.lm-store-grid .lm-store-item .store-name {\n  font-size: 14px;\n  font-weight: 600;\n  color: var(--primary);\n  margin-bottom: 6px;\n}\n\n.lm-store-grid .lm-store-item .store-addr {\n  font-size: 12px;\n  color: var(--text-light);\n  line-height: 1.5;\n}\n\n\/* ===== Gallery ===== *\/\n.lm-gallery {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(200px, 1fr));\n  gap: 12px;\n  margin: 16px 0;\n}\n\n.lm-gallery .lm-gallery-item {\n  background: var(--bg-soft);\n  border-radius: var(--radius);\n  padding: 20px;\n  text-align: center;\n  border: 1px solid var(--border);\n  font-size: 13px;\n  color: var(--text-light);\n}\n\n\/* ===== Brand Cert Photos ===== *\/\n.lm-cert-photos {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(240px, 1fr));\n  gap: 16px;\n  margin: 16px 0 8px;\n}\n\n.lm-cert-photo {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 12px;\n  margin: 0;\n  box-shadow: var(--shadow);\n  transition: box-shadow 0.2s, transform 0.2s;\n}\n\n.lm-cert-photo:hover {\n  box-shadow: var(--shadow-md);\n  transform: translateY(-2px);\n}\n\n.lm-cert-photo img {\n  width: 100%;\n  height: auto;\n  border-radius: var(--radius);\n  display: block;\n  background: var(--bg-soft);\n}\n\n.lm-cert-photo figcaption {\n  text-align: center;\n  font-size: 13px;\n  color: var(--text-light);\n  margin-top: 10px;\n  line-height: 1.5;\n}\n\n\/* ===== Store photos single column ===== *\/\n.lm-store-photos {\n  display: flex;\n  flex-direction: row;\n  flex-wrap: wrap;\n  justify-content: center;\n  align-items: flex-start;\n  gap: 16px;\n  margin-top: 8px;\n}\n\n.lm-store-photos .lm-cert-photo {\n  flex: 1 1 280px;\n  max-width: 480px;\n}\n\n\/* ===== Charts & Visualizations ===== *\/\n.lm-chart-wrap {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 20px;\n  margin: 16px 0 24px;\n  box-shadow: var(--shadow);\n}\n\n.lm-chart-wrap h4 {\n  margin: 0 0 12px;\n  font-size: 16px;\n  color: var(--text-main);\n}\n\n.lm-radar-canvas {\n  max-width: 560px;\n  margin: 0 auto;\n}\n\n.lm-cost-chart {\n  display: flex;\n  flex-direction: column;\n  gap: 14px;\n  margin: 16px 0;\n}\n\n.lm-cost-row {\n  display: flex;\n  align-items: center;\n  gap: 12px;\n}\n\n.lm-cost-label {\n  width: 140px;\n  font-size: 13px;\n  font-weight: 600;\n  color: var(--text-main);\n  text-align: right;\n  flex-shrink: 0;\n}\n\n.lm-cost-bar {\n  flex: 1;\n  display: flex;\n  height: 28px;\n  border-radius: 6px;\n  overflow: hidden;\n  background: var(--bg-soft);\n  min-width: 120px;\n}\n\n.lm-cost-seg {\n  height: 100%;\n  position: relative;\n}\n\n.lm-cost-seg.init { background: #8B2E2E; }\n.lm-cost-seg.run { background: #D4A84B; }\n.lm-cost-seg.maint { background: #28a745; }\n.lm-cost-seg.replace { background: #4a6fa5; }\n\n.lm-cost-total {\n  width: 90px;\n  font-size: 13px;\n  font-weight: 700;\n  color: var(--text-main);\n  flex-shrink: 0;\n}\n\n.lm-cost-legend {\n  display: flex;\n  flex-wrap: wrap;\n  justify-content: center;\n  gap: 16px;\n  margin-top: 12px;\n  font-size: 12px;\n  color: var(--text-light);\n}\n\n.lm-cost-legend span {\n  display: inline-flex;\n  align-items: center;\n  gap: 6px;\n}\n\n.lm-cost-legend i {\n  width: 12px;\n  height: 12px;\n  border-radius: 3px;\n  display: inline-block;\n}\n\n\/* ===== Construction Photo Gallery ===== *\/\n.lm-construct-gallery {\n  display: grid;\n  grid-template-columns: repeat(auto-fill, minmax(240px, 1fr));\n  gap: 16px;\n  margin: 16px 0 24px;\n}\n\n@media (max-width: 640px) {\n  .lm-construct-gallery {\n    display: flex;\n    overflow-x: auto;\n    scroll-snap-type: x mandatory;\n    padding-bottom: 8px;\n  }\n  .lm-construct-item {\n    flex: 0 0 260px;\n    scroll-snap-align: start;\n  }\n}\n\n.lm-construct-item {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  overflow: hidden;\n  box-shadow: var(--shadow);\n  transition: box-shadow 0.2s, transform 0.2s;\n}\n\n.lm-construct-item:hover {\n  box-shadow: var(--shadow-md);\n  transform: translateY(-2px);\n}\n\n.lm-construct-item img {\n  width: 100%;\n  aspect-ratio: 16 \/ 9;\n  object-fit: cover;\n  display: block;\n}\n\n.lm-construct-item figcaption {\n  padding: 10px 12px;\n  font-size: 12px;\n  color: var(--text-light);\n  text-align: center;\n  line-height: 1.5;\n}\n\n\/* ===== Product Link Card ===== *\/\n.lm-product-card {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 16px;\n  align-items: center;\n  background: linear-gradient(135deg, var(--bg-soft) 0%, var(--bg-card) 100%);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 16px;\n  margin: 16px 0 20px;\n  box-shadow: var(--shadow);\n}\n\n.lm-product-card img {\n  width: 160px;\n  height: 150px;\n  object-fit: contain;\n  border-radius: var(--radius);\n  background: #fff;\n  flex-shrink: 0;\n  border: 1px solid var(--border);\n}\n\n.lm-product-info {\n  flex: 1 1 220px;\n}\n\n.lm-product-info h4 {\n  margin: 0 0 6px;\n  font-size: 16px;\n  color: var(--text-main);\n}\n\n.lm-product-info p {\n  margin: 0 0 10px;\n  font-size: 13px;\n  color: var(--text-light);\n  line-height: 1.6;\n}\n\n.lm-product-info a {\n  display: inline-flex;\n  align-items: center;\n  gap: 6px;\n  background: var(--primary);\n  color: #fff;\n  padding: 8px 16px;\n  border-radius: 999px;\n  font-size: 13px;\n  text-decoration: none;\n  transition: background 0.2s;\n}\n\n.lm-product-info a:hover {\n  background: var(--primary-dark);\n}\n\n\/* ===== Store Showroom Section ===== *\/\n.lm-showroom {\n  background: linear-gradient(180deg, var(--bg-soft) 0%, var(--bg-card) 100%);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  padding: 32px 24px;\n  margin-top: 16px;\n}\n\n.lm-showroom-head {\n  text-align: center;\n  margin-bottom: 24px;\n}\n\n.lm-showroom-head h2 {\n  font-size: 26px;\n  margin: 0 0 8px;\n  color: var(--text-main);\n}\n\n.lm-showroom-head p {\n  color: var(--text-light);\n  margin: 0;\n}\n\n.lm-showroom-contacts {\n  display: flex;\n  flex-wrap: wrap;\n  justify-content: center;\n  gap: 12px;\n  margin-bottom: 20px;\n}\n\n.lm-showroom-contact {\n  display: inline-flex;\n  align-items: center;\n  gap: 8px;\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: 999px;\n  padding: 10px 18px;\n  font-size: 14px;\n  color: var(--text-main);\n  text-decoration: none;\n  box-shadow: var(--shadow);\n  transition: box-shadow 0.2s, transform 0.2s;\n}\n\n.lm-showroom-contact:hover {\n  box-shadow: var(--shadow-md);\n  transform: translateY(-2px);\n  border-color: var(--primary);\n}\n\n.lm-showroom-contact .icon {\n  width: 20px;\n  height: 20px;\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  font-size: 14px;\n}\n\n.lm-showroom-tags {\n  display: flex;\n  flex-wrap: wrap;\n  justify-content: center;\n  gap: 10px;\n  margin-bottom: 28px;\n}\n\n.lm-showroom-tag {\n  display: inline-flex;\n  align-items: center;\n  gap: 6px;\n  background: #fff;\n  border: 1px solid var(--border);\n  border-radius: 8px;\n  padding: 8px 14px;\n  font-size: 13px;\n  color: var(--text-main);\n}\n\n.lm-showroom-shots {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n  gap: 16px;\n  margin-bottom: 24px;\n}\n\n.lm-showroom-shot {\n  background: var(--bg-card);\n  border-radius: var(--radius-lg);\n  overflow: hidden;\n  box-shadow: var(--shadow);\n}\n\n.lm-showroom-shot img {\n  width: 100%;\n  aspect-ratio: 16 \/ 9;\n  object-fit: cover;\n  display: block;\n}\n\n.lm-showroom-shot figcaption {\n  padding: 12px;\n  text-align: center;\n}\n\n.lm-showroom-shot .store-name {\n  font-weight: 700;\n  color: var(--text-main);\n  margin-bottom: 4px;\n}\n\n.lm-showroom-shot .store-addr {\n  font-size: 12px;\n  color: var(--text-light);\n}\n\n.lm-showroom-coverage {\n  text-align: center;\n  color: var(--text-light);\n  font-size: 13px;\n  margin-bottom: 20px;\n}\n\n.lm-showroom-cta {\n  text-align: center;\n  margin-bottom: 12px;\n}\n\n.lm-showroom-cta a {\n  display: inline-flex;\n  align-items: center;\n  gap: 8px;\n  background: linear-gradient(135deg, #c0392b 0%, #e74c3c 100%);\n  color: #fff;\n  font-size: 16px;\n  font-weight: 700;\n  padding: 14px 36px;\n  border-radius: 999px;\n  text-decoration: none;\n  box-shadow: 0 8px 20px rgba(192,57,43,0.25);\n  transition: transform 0.2s, box-shadow 0.2s;\n}\n\n.lm-showroom-cta a:hover {\n  transform: translateY(-2px);\n  box-shadow: 0 12px 28px rgba(192,57,43,0.35);\n}\n\n.lm-showroom-note {\n  text-align: center;\n  font-size: 12px;\n  color: var(--text-light);\n}\n\n\/* ===== Footer ===== *\/\nfooter {\n  background: var(--primary-dark);\n  color: #fff;\n  padding: 40px 20px 24px;\n  text-align: center;\n  font-size: 14px;\n  line-height: 1.8;\n}\n\nfooter .footer-brand {\n  font-size: 20px;\n  color: #fff;\n  font-weight: 700;\n  margin-bottom: 8px;\n  letter-spacing: 2px;\n  text-shadow: 0 2px 4px rgba(0,0,0,0.3);\n}\n\nfooter .footer-tagline {\n  color: #f2c94c;\n  font-size: 14px;\n  margin-bottom: 16px;\n  font-weight: 500;\n  letter-spacing: 1px;\n}\n\nfooter a {\n  color: #fff;\n  text-decoration: underline;\n  text-underline-offset: 3px;\n}\n\nfooter a:hover {\n  color: #f2c94c;\n}\n\nfooter p {\n  color: #fff;\n}\n\nfooter .footer-disclaimer {\n  margin-top: 20px;\n  padding-top: 16px;\n  border-top: 1px solid rgba(255,255,255,0.15);\n  font-size: 12px;\n  color: rgba(255,255,255,0.9);\n  max-width: 700px;\n  margin-left: auto;\n  margin-right: auto;\n  line-height: 1.7;\n}\n\n\/* ===== S1 S-curve Goal Flow ===== *\/\n.lm-goal-flow {\n  position: relative;\n  min-height: 720px;\n  margin: 20px 0;\n  padding: 10px 0;\n}\n\n.lm-goal-flow svg {\n  position: absolute;\n  top: 0;\n  left: 0;\n  width: 100%;\n  height: 100%;\n  z-index: 0;\n  pointer-events: none;\n}\n\n.lm-goal-flow path {\n  fill: none;\n  stroke: var(--border-strong);\n  stroke-width: 3;\n  stroke-dasharray: 8 6;\n}\n\n.lm-goal-node {\n  position: absolute;\n  width: 42%;\n  background: var(--bg-card);\n  border-radius: var(--radius-lg);\n  padding: 18px 20px;\n  box-shadow: var(--shadow);\n  border: 1px solid var(--border);\n  z-index: 1;\n  transition: box-shadow 0.2s, transform 0.2s;\n}\n\n.lm-goal-node:hover {\n  box-shadow: var(--shadow-md);\n  transform: translateY(-2px);\n}\n\n.lm-goal-node:nth-child(2) { top: 3%;  left: 4%; }\n.lm-goal-node:nth-child(3) { top: 21%; left: 54%; }\n.lm-goal-node:nth-child(4) { top: 41%; left: 4%; }\n.lm-goal-node:nth-child(5) { top: 59%; left: 54%; }\n.lm-goal-node:nth-child(6) { top: 78%; left: 29%; width: 44%; }\n\n.lm-goal-node .num {\n  width: 34px;\n  height: 34px;\n  border-radius: 50%;\n  background: var(--primary);\n  color: #fff;\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  font-weight: 700;\n  font-size: 14px;\n  margin-bottom: 10px;\n}\n\n.lm-goal-node h4 {\n  margin: 0 0 8px;\n  font-size: 15px;\n  color: var(--primary);\n}\n\n.lm-goal-node p {\n  margin: 0;\n  font-size: 13px;\n  color: var(--text-light);\n  line-height: 1.7;\n}\n\n\/* Goal node lighting sequence \u2014 synced with the 6s flag travel (light \u2192 deep) *\/\n.lm-goal-node:nth-child(2) { animation: lmNode1 6s linear infinite; }\n.lm-goal-node:nth-child(3) { animation: lmNode2 6s linear infinite; }\n.lm-goal-node:nth-child(4) { animation: lmNode3 6s linear infinite; }\n.lm-goal-node:nth-child(5) { animation: lmNode4 6s linear infinite; }\n.lm-goal-node:nth-child(6) { animation: lmNode5 6s linear infinite; }\n\n@keyframes lmNode1 {\n  0%, 100% {\n    background: #e8f1fb;\n    border-color: #9fc4e8;\n    box-shadow: 0 0 0 2px rgba(63,134,198,.25), var(--shadow);\n  }\n}\n@keyframes lmNode2 {\n  0%, 24% { background: var(--bg-card); border-color: var(--border); box-shadow: var(--shadow); }\n  25%, 100% {\n    background: #cfe4f7;\n    border-color: #7fb0e0;\n    box-shadow: 0 0 0 2px rgba(63,134,198,.30), var(--shadow);\n  }\n}\n@keyframes lmNode3 {\n  0%, 49% { background: var(--bg-card); border-color: var(--border); box-shadow: var(--shadow); }\n  50%, 100% {\n    background: #a9d0f0;\n    border-color: #5a9fd8;\n    box-shadow: 0 0 0 3px rgba(63,134,198,.35), var(--shadow);\n  }\n}\n@keyframes lmNode4 {\n  0%, 74% { background: var(--bg-card); border-color: var(--border); box-shadow: var(--shadow); }\n  75%, 100% {\n    background: #79b3e0;\n    border-color: #3f86c6;\n    box-shadow: 0 0 0 3px rgba(63,134,198,.40), var(--shadow);\n  }\n}\n@keyframes lmNode5 {\n  0%, 91% { background: var(--bg-card); border-color: var(--border); box-shadow: var(--shadow); }\n  92%, 100% {\n    background: #4f93cf;\n    border-color: #2f6aa8;\n    box-shadow: 0 0 0 4px rgba(63,134,198,.45), var(--shadow);\n  }\n}\n\n\/* ===== Floor Heating Flip Cards ===== *\/\n.lm-floor-grid {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 20px;\n  margin: 20px 0 24px;\n}\n\n.lm-floor-grid .lm-flip-card {\n  margin-bottom: 0;\n}\n\n.lm-floor-grid .lm-flip-inner {\n  min-height: 520px;\n}\n\n.lm-floor-front {\n  background: linear-gradient(135deg, #fff 0%, var(--bg-soft) 100%);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  box-shadow: var(--shadow);\n  overflow: hidden;\n  position: absolute;\n  top: 0;\n  left: 0;\n  width: 100%;\n  height: 100%;\n  backface-visibility: hidden;\n  -webkit-backface-visibility: hidden;\n  z-index: 2;\n  display: flex;\n  flex-direction: column;\n}\n\n.lm-floor-front img {\n  width: 100%;\n  height: 240px;\n  object-fit: contain;\n  background: #fff;\n  border-bottom: 1px solid var(--border);\n  padding: 16px;\n  display: block;\n}\n\n.lm-floor-front-body {\n  padding: 18px;\n  text-align: center;\n  flex: 1;\n  display: flex;\n  flex-direction: column;\n  justify-content: center;\n}\n\n.lm-floor-front-body h4 {\n  margin: 0 0 6px;\n  font-size: 17px;\n  color: var(--primary);\n}\n\n.lm-floor-front-body .model {\n  font-size: 13px;\n  color: var(--text-light);\n  margin-bottom: 12px;\n}\n\n.lm-floor-front-body .price {\n  font-size: 24px;\n  color: var(--accent);\n  font-weight: 700;\n  margin-bottom: 12px;\n}\n\n.lm-floor-front-body .price-note {\n  font-size: 12px;\n  color: var(--text-light);\n  margin-bottom: 14px;\n}\n\n.lm-floor-front-body .detail-link {\n  display: inline-block;\n  font-size: 13px;\n  color: var(--primary-light);\n  text-decoration: none;\n  margin-bottom: 8px;\n}\n\n.lm-floor-front-body .detail-link:hover {\n  color: var(--accent);\n}\n\n.lm-floor-front-body .hint {\n  font-size: 12px;\n  color: var(--text-light);\n}\n\n.lm-floor-back {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius-lg);\n  box-shadow: var(--shadow);\n  position: absolute;\n  top: 0;\n  left: 0;\n  width: 100%;\n  height: 100%;\n  backface-visibility: hidden;\n  -webkit-backface-visibility: hidden;\n  transform: rotateY(180deg);\n  padding: 18px;\n  overflow-y: auto;\n}\n\n.lm-floor-back h4 {\n  margin: 0 0 12px;\n  font-size: 15px;\n  color: var(--primary);\n  text-align: center;\n}\n\n.lm-floor-back table {\n  font-size: 12px;\n  margin: 0;\n  box-shadow: none;\n}\n\n.lm-floor-back th,\n.lm-floor-back td {\n  padding: 6px 8px;\n}\n\n.lm-floor-back th {\n  background: var(--bg-soft);\n  color: var(--primary);\n  font-size: 12px;\n}\n\n.lm-floor-back td {\n  border-bottom: 1px solid var(--border);\n}\n\n.lm-floor-back .lm-flip-hint {\n  margin-top: 10px;\n}\n\n\/* ===== AI Verification Checklist Accordion ===== *\/\n.lm-checklist {\n  margin: 16px 0 24px;\n}\n\n.lm-check-item {\n  background: var(--bg-card);\n  border: 1px solid var(--border);\n  border-radius: var(--radius);\n  margin-bottom: 10px;\n  overflow: hidden;\n  box-shadow: var(--shadow);\n}\n\n.lm-check-header {\n  padding: 14px 18px;\n  display: flex;\n  align-items: center;\n  justify-content: space-between;\n  gap: 12px;\n  cursor: pointer;\n  background: var(--bg-soft);\n  user-select: none;\n  transition: background 0.2s;\n}\n\n.lm-check-header:hover {\n  background: #e6eff7;\n}\n\n.lm-check-title {\n  display: flex;\n  align-items: center;\n  gap: 10px;\n  font-size: 14px;\n  font-weight: 600;\n  color: var(--primary);\n}\n\n.lm-check-title .icon {\n  width: 26px;\n  height: 26px;\n  border-radius: 50%;\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  font-size: 13px;\n  flex-shrink: 0;\n}\n\n.lm-check-item.pass .lm-check-title .icon { background: #d4edda; color: #155724; }\n.lm-check-item.warn .lm-check-title .icon { background: #fff3cd; color: #856404; }\n\n.lm-check-toggle {\n  width: 24px;\n  height: 24px;\n  border-radius: 50%;\n  background: #fff;\n  border: 1px solid var(--border);\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  font-size: 12px;\n  color: var(--text-light);\n  transition: transform 0.25s ease;\n  flex-shrink: 0;\n}\n\n.lm-check-item.active .lm-check-toggle {\n  transform: rotate(180deg);\n}\n\n.lm-check-body {\n  max-height: 0;\n  opacity: 0;\n  overflow: hidden;\n  transition: max-height 0.35s ease, opacity 0.25s ease, padding 0.35s ease;\n  padding: 0 18px;\n}\n\n.lm-check-item.active .lm-check-body {\n  max-height: 300px;\n  opacity: 1;\n  padding: 14px 18px;\n}\n\n.lm-check-body p {\n  margin: 0 0 8px;\n  font-size: 13px;\n  color: var(--text);\n  line-height: 1.7;\n}\n\n.lm-check-body p:last-child {\n  margin-bottom: 0;\n}\n\n.lm-check-body .note {\n  color: var(--text-light);\n}\n\n\/* ===== Responsive ===== *\/\n@media (max-width: 768px) {\n  .cover-panel {\n    padding: 28px 24px;\n    width: 94%;\n  }\n  .cover-panel h1 {\n    font-size: 22px;\n  }\n  .cover-info {\n    grid-template-columns: 1fr;\n  }\n  .lm-subnav {\n    justify-content: flex-start;\n    gap: 8px;\n    padding: 8px 12px;\n  }\n  .lm-nav-item,\n  .lm-nav-link {\n    flex-shrink: 0;\n  }\n  .lm-two-col {\n    grid-template-columns: 1fr;\n  }\n  table {\n    font-size: 12px;\n  }\n  th, td {\n    padding: 7px 8px;\n  }\n  .lm-wrap {\n    padding: 24px 14px 40px;\n  }\n  section > h2 {\n    font-size: 19px;\n  }\n  h3 {\n    font-size: 16px;\n  }\n  .lm-floor-grid {\n    grid-template-columns: 1fr;\n  }\n  .lm-floor-grid .lm-flip-inner {\n    min-height: 480px;\n  }\n  .lm-goal-flow {\n    min-height: auto;\n    padding: 0;\n  }\n  .lm-goal-flow svg {\n    display: none;\n  }\n  .lm-goal-node {\n    position: relative;\n    top: auto !important;\n    left: auto !important;\n    width: 100%;\n    margin-bottom: 14px;\n  }\n  .lm-goal-node:nth-child(6) {\n    width: 100%;\n  }\n  .lm-goal-node { animation: none !important; }\n  .lm-goal-node:nth-child(2) { background: #e8f1fb; border-color: #9fc4e8; }\n  .lm-goal-node:nth-child(3) { background: #cfe4f7; border-color: #7fb0e0; }\n  .lm-goal-node:nth-child(4) { background: #a9d0f0; border-color: #5a9fd8; }\n  .lm-goal-node:nth-child(5) { background: #79b3e0; border-color: #3f86c6; }\n  .lm-goal-node:nth-child(6) { background: #4f93cf; border-color: #2f6aa8; }\n}\n\n@media (max-width: 480px) {\n  table {\n    font-size: 11px;\n  }\n  th, td {\n    padding: 6px;\n  }\n}\n<\/style>\n\n<header class=\"cover\">\n  <div class=\"cover-panel\">\n    <div class=\"cover-tag\">\u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u524d\u4e66<\/div>\n    <h2>\u897f\u6d3e\u5c11\u57ce \u00b7 \u8463\u5148\u751f\u6696\u901a\u65b9\u6848\u524d\u4e66<\/h2>\n    <div class=\"cover-sub\">\u5929\u6c1f\u5730\u6c34 vs \u5929\u6c34\u5730\u6c34 vs \u8212\u4eab\u6c1f\u673a \u00b7 \u7a7a\u8c03\u4e09\u65b9\u6848 + \u5730\u6696\u4e09\u65b9\u6848 \u5168\u7ef4\u5ea6\u5bf9\u6bd4<\/div>\n    <div class=\"cover-info\">\n      <div class=\"cover-info-item\"><span class=\"label\">\u5ba2\u6237<\/span><span class=\"value\">\u8463\u5148\u751f<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u5c0f\u533a<\/span><span class=\"value\">\u897f\u6d3e\u5c11\u57ce\uff08\u9752\u7f8a\u533a\uff09<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u6237\u578b<\/span><span class=\"value\">\u5927\u5e73\u5c42 260\u33a1<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u697c\u5c42<\/span><span class=\"value\">31\u697c \/ \u603b\u9ad835\u697c<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u5e38\u4f4f\u4eba\u53e3<\/span><span class=\"value\">4\u4eba\uff082\u59272\u5c0f\uff0c\u540e\u671f\u6216+1\uff09<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u88c5\u4fee\u8fdb\u5ea6<\/span><span class=\"value\">\u8bbe\u8ba1\u4e2d\uff0c\u672a\u5f00\u5de5<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u9500\u552e\u987e\u95ee<\/span><span class=\"value\">\u4f59\u7231\u82f1 \u00b7 \u4ece\u4e1a14\u5e74<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u6c9f\u901a\u65e5\u671f<\/span><span class=\"value\">2026\u5e747\u670818\u65e5 \u00b7 \u5357\u5bcc\u68ee\u95e8\u5e97<\/span><\/div>\n    <\/div>\n  <\/div>\n<\/header>\n\n<nav class=\"lm-breadcrumb\" aria-label=\"breadcrumb\">\n  <ol>\n    <li><a href=\"https:\/\/longmai-nt.com\">\u9f99\u8109\u6696\u901a<\/a><\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=2705\">\u65b9\u6848\u4e2d\u5fc3<\/a><\/li>\n    <li aria-current=\"page\">\u897f\u6d3e\u5c11\u57ce\u00b7\u8463\u5148\u751f\u6696\u901a\u65b9\u6848\u524d\u4e66<\/li>\n  <\/ol>\n<\/nav>\n\n<nav class=\"lm-subnav\" aria-label=\"\u76ee\u5f55\u5bfc\u822a\">\n  <div class=\"lm-nav-item\">\n    <button class=\"lm-nav-toggle\" data-target=\"nav-s1\" aria-expanded=\"false\">S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 <span class=\"lm-caret\">\u25be<\/span><\/button>\n    <div class=\"lm-nav-panel\" id=\"nav-s1\">\n      <a href=\"#s1\">\u5ba2\u6237\u4fe1\u606f<\/a>\n      <a href=\"#s1-load\">\u51b7\u8d1f\u8377\u5206\u6790<\/a>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-nav-item\">\n    <button class=\"lm-nav-toggle\" data-target=\"nav-s2\" aria-expanded=\"false\">S2\u00b7\u9700\u6c42\u75db\u70b9\u8bca\u65ad <span class=\"lm-caret\">\u25be<\/span><\/button>\n    <div class=\"lm-nav-panel\" id=\"nav-s2\">\n      <a href=\"#s2\">\u75db\u70b9\u8bca\u65ad<\/a>\n      <a href=\"#s2-constraint\">\u9690\u6027\u7ea6\u675f<\/a>\n      <a href=\"#s2-compare\">\u6c34\u673a vs \u6c1f\u673a<\/a>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-nav-item\">\n    <button class=\"lm-nav-toggle\" data-target=\"nav-s3\" aria-expanded=\"false\">S3\u00b7\u65b9\u6848\u6210\u672c\u5bf9\u6bd4 <span class=\"lm-caret\">\u25be<\/span><\/button>\n    <div class=\"lm-nav-panel\" id=\"nav-s3\">\n      <a href=\"#s3\">\u4e09\u65b9\u6848\u6982\u89c8<\/a>\n      <a href=\"#s3-a\">\u65b9\u6848A \u5929\u6c1f\u5730\u6c34<\/a>\n      <a href=\"#s3-b\">\u65b9\u6848B \u8212\u4eab\u6c1f\u673a<\/a>\n      <a href=\"#s3-c\">\u65b9\u6848C \u5929\u6c34\u5730\u6c34<\/a>\n      <a href=\"#s3-floor\">\u5730\u6696\u5bf9\u6bd4<\/a>\n      <a href=\"#s3-freshair\">\u65b0\u98ce\u7cfb\u7edf<\/a>\n      <a href=\"#s3-six\">\u4e5d\u7ef4\u5ea6\u5bf9\u6bd4<\/a>\n      <a href=\"#s3-summary\">\u62a5\u4ef7\u6c47\u603b<\/a>\n      <a href=\"#s3-20yr\">20\u5e74\u603b\u8d26<\/a>\n    <\/div>\n  <\/div>\n\n  <a class=\"lm-nav-link\" href=\"#s4\">S4\u00b7\u65bd\u5de5\u4ea4\u4ed8\u4fdd\u969c<\/a>\n  <a class=\"lm-nav-link\" href=\"#s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<\/a>\n  <a class=\"lm-nav-link\" href=\"#showroom\">\u95e8\u5e97\u670d\u52a1<\/a>\n  <a class=\"lm-nav-link\" href=\"#certificates\">\u6388\u6743\u8bc1\u4e66<\/a>\n  <a class=\"lm-nav-link\" href=\"#faq\">FAQ<\/a>\n  <a class=\"lm-nav-link\" href=\"#links\">\u5ef6\u4f38\u9605\u8bfb<\/a>\n<\/nav>\n\n<div class=\"lm-wrap\">\n\n<section id=\"s1\">\n  <h2>S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n\n  <div class=\"lm-flip-card\" id=\"customerCard\" onclick=\"this.classList.toggle('flipped')\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\">\n        <div class=\"lm-info-card\" style=\"margin:0; height:100%;\">\n          <h3>\u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n          <div class=\"lm-kv\">\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5ba2\u6237\u59d3\u540d<\/span><span class=\"v\">\u8463\u5148\u751f<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5c0f\u533a<\/span><span class=\"v\">\u897f\u6d3e\u5c11\u57ce<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u533a\u57df<\/span><span class=\"v\">\u9752\u7f8a\u533a<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u6237\u578b<\/span><span class=\"v\">\u5927\u5e73\u5c42<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5efa\u7b51\u9762\u79ef<\/span><span class=\"v\">260\u33a1<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u697c\u5c42<\/span><span class=\"v\">31\u697c \/ \u603b\u9ad835\u697c<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5e38\u4f4f\u4eba\u53e3<\/span><span class=\"v\">4\u4eba\uff082\u59272\u5c0f\uff09\uff0c\u540e\u671f\u6216+1<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u88c5\u4fee\u8fdb\u5ea6<\/span><span class=\"v\">\u8bbe\u8ba1\u4e2d\uff0c\u672a\u5f00\u5de5<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u9884\u7b97\u533a\u95f4<\/span><span class=\"v\">10-13\u4e07<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u9500\u552e\u987e\u95ee<\/span><span class=\"v\">\u4f59\u7231\u82f1<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u987e\u95ee\u4ece\u4e1a<\/span><span class=\"v\">14\u5e74\uff082012\u5e74\u52a0\u5165\u9f99\u8109\uff09<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u6c9f\u901a\u65e5\u671f<\/span><span class=\"v\">2026\u5e747\u670818\u65e5<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u6c9f\u901a\u95e8\u5e97<\/span><span class=\"v\">\u5357\u5bcc\u68ee\u95e8\u5e97<\/span><\/div>\n          <\/div>\n\n          <h4>\u73b0\u623f\u4f7f\u7528\u4f53\u9a8c\uff08170\u33a1\u7cbe\u88c5\u623f\uff09<\/h4>\n          <div class=\"lm-kv\">\n            <div class=\"lm-kv-item\"><span class=\"k\">\u73b0\u623f\u9762\u79ef<\/span><span class=\"v\">170\u33a1\u7cbe\u88c5\u623f<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u73b0\u6709\u7a7a\u8c03<\/span><span class=\"v\">\u683c\u529b\u6c1f\u673a<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u73b0\u6709\u5730\u6696<\/span><span class=\"v\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5730\u6696\u6708\u8d39<\/span><span class=\"v\">\u7ea6700\u5143\/\u6708\uff08\u542b\u751f\u6d3b\u7528\u6c14\uff09<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5730\u6696\u9ad8\u5cf0<\/span><span class=\"v\">\u4e24\u4e2a\u6708\u6700\u9ad81300+\u5143<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5ba4\u5185\u6e29\u5ea6<\/span><span class=\"v\">22-23\u2103<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u5f00\u542f\u65f6\u95f4<\/span><span class=\"v\">11\u6708-3\u6708\uff08\u7ea65\u4e2a\u6708\uff09<\/span><\/div>\n            <div class=\"lm-kv-item\"><span class=\"k\">\u6838\u5fc3\u8bc9\u6c42<\/span><span class=\"v\">\u51b2\u7740\u6c34\u673a\u8212\u9002\u5ea6\u6765<\/span><\/div>\n          <\/div>\n\n          <div class=\"lm-flip-hint\">\ud83d\udca1 \u70b9\u51fb\u5361\u7247\u67e5\u770b\u5ba2\u6237\u6210\u529f\u76ee\u6807\u5b9a\u4e49<\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"lm-flip-back\">\n        <h3>\u5ba2\u6237\u6210\u529f\u76ee\u6807\u5b9a\u4e49<\/h3>\n        <div class=\"lm-goal-flow\">\n          <svg viewBox=\"0 0 1000 720\" preserveAspectRatio=\"none\">\n            <path id=\"goalPath\" d=\"M 220 40 C 220 130, 780 110, 780 200 C 780 290, 220 270, 220 360 C 220 450, 780 430, 780 520 C 780 600, 500 580, 500 660\"><\/path>\n            <g style=\"filter: drop-shadow(0 2px 3px rgba(0,0,0,.15));\">\n              <g>\n                <animateMotion dur=\"6s\" repeatCount=\"indefinite\" rotate=\"auto\" keyPoints=\"0;1\" keyTimes=\"0;1\" calcMode=\"linear\">\n                  <mpath href=\"#goalPath\"><\/mpath>\n                <\/animateMotion>\n                <g transform=\"translate(0,-16)\">\n                  <line x1=\"0\" y1=\"0\" x2=\"0\" y2=\"22\" stroke=\"#b71c1c\" stroke-width=\"2\" stroke-linecap=\"round\"><\/line>\n                  <path d=\"M0,2 L16,7 L0,12 Z\" fill=\"#e53935\" stroke=\"#b71c1c\" stroke-width=\"1.2\" stroke-linejoin=\"round\"><\/path>\n                <\/g>\n              <\/g>\n            <\/g>\n          <\/svg>\n          <div class=\"lm-goal-node\">\n            <div class=\"num\">1<\/div>\n            <h4>\u89e3\u51b3\"\u8d8a\u5439\u8d8a\u51b7\"\u7684\u6838\u5fc3\u75db\u70b9<\/h4>\n            <p>\u8463\u5148\u751f\u73b0\u623f\u683c\u529b\u6c1f\u673a\u51fa\u98ce7-10\u2103\uff0c\u6e29\u5dee\u5927\u3001\u5439\u4e45\u4e0d\u8212\u670d\uff0c\u5c24\u5176\u5bb6\u91cc\u6709\u4e24\u4e2a\u5c0f\u5b69\u3002\u65b0\u65b9\u6848\u987b\u5b9e\u73b0\u51fa\u98ce\u6e29\u5ea615-17\u2103\uff08\u6c34\u673a\uff09\u6216\u6e29\u6e7f\u53cc\u63a7\uff08\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\uff09\uff0c\u6d88\u9664\"\u751f\u51b7\u611f\"\u3002<\/p>\n          <\/div>\n          <div class=\"lm-goal-node\">\n            <div class=\"num\">2<\/div>\n            <h4>\u63a7\u5236\u566a\u97f3\u5728\u53ef\u63a5\u53d7\u8303\u56f4<\/h4>\n            <p>\u73b0\u623f\u6c1f\u673a\u566a\u97f3\"\u6709\u70b9\u5927\"\uff0c\u53ef\u80fd\u4e0e\u5b89\u88c5\u5de5\u827a\u6709\u5173\u3002\u65b0\u65b9\u6848\u987b\u786e\u4fdd\u5185\u673a\u566a\u97f3\u226435dB(A)\uff0c\u5916\u673a\u4f4d\u9009\u62e9\u907f\u5f00\u4e3b\u5367\u548c\u5973\u513f\u623f\u95f4\u65b9\u5411\uff0c\u5b89\u88c5\u4e25\u683c\u6267\u884c<\/p>\n          <\/div>\n          <div class=\"lm-goal-node\">\n            <div class=\"num\">3<\/div>\n            <h4>\u5730\u6696\u8054\u52a8\u63a7\u5236\uff0c\u675c\u7edd\u9505\u7089\u9891\u7e41\u542f\u505c<\/h4>\n            <p>\u73b0\u623f\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u65e0\u8054\u52a8\u63a7\u5236\uff0c\u9505\u7089\u9891\u7e41\u542f\u505c\u505a\u65e0\u6548\u529f\u3002\u65b0\u65b9\u6848\u987b\u914d\u7f6e\u5ba4\u5185\u6e29\u63a7\u5668+\u8054\u52a8\u6a21\u5757\uff0c\u5ba4\u5185\u6e29\u5ea6\u8fbe\u6807\u540e\u901a\u77e5\u9505\u7089\u505c\u6b62\uff0c\u5b9e\u73b0\u8282\u80fd\u8fd0\u884c\u3002\u4e3b\u7ba1\u5fc5\u987b\u752840\u7ba1\uff08\u8be6\u89c1<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?p=1337\" target=\"_blank\">\u8f85\u6750\u914d\u7f6e\u6807\u51c6<\/a>\uff09\u3002<\/p>\n          <\/div>\n          <div class=\"lm-goal-node\">\n            <div class=\"num\">4<\/div>\n            <h4>\u53a8\u623f\u7a7a\u8c03\u89e3\u51b3\u590f\u5929\u505a\u996d\u70ed<\/h4>\n            <p>9.67\u33a1\u53a8\u623f\u9700\u914d\u7f6e\u4e13\u7528\u7a7a\u8c03\u5185\u673a\uff0c\u9632\u6cb9\u6c61\u8bbe\u8ba1\uff0c\u5355\u72ec\u98ce\u9053\u3002\u65b9\u6848A\/B\u5747\u914d\u7f6eRCIS-22FSCN1QD\u53a8\u623f\u4e13\u7528\u5185\u673a\u3002<\/p>\n          <\/div>\n          <div class=\"lm-goal-node\">\n            <div class=\"num\">5<\/div>\n            <h4>\u603b\u4ef7\u63a7\u5236\u572810-13\u4e07\u9884\u7b97\u533a\u95f4<\/h4>\n            <p>\u5728\u6ee1\u8db3\u4ee5\u4e0a4\u4e2a\u76ee\u6807\u7684\u524d\u63d0\u4e0b\uff0c\u7a7a\u8c03+\u5730\u6696\u7ec4\u5408\u603b\u4ef7\u63a7\u5236\u572810-13\u4e07\u3002\u901a\u8fc7\u4e09\u5957\u7a7a\u8c03\u65b9\u6848\u00d7\u4e09\u5957\u5730\u6696\u65b9\u6848\u7684\u7ec4\u5408\u77e9\u9635\uff0c\u627e\u5230\u6700\u4f18\u6027\u4ef7\u6bd4\u65b9\u6848\u3002<\/p>\n          <\/div>\n        <\/div>\n        <div class=\"lm-flip-hint\">\ud83d\udca1 \u70b9\u51fb\u5361\u7247\u8fd4\u56de\u5ba2\u6237\u4fe1\u606f\u5361<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s1-load\">\u51b7\u8d1f\u8377\u5206\u6790 \u00b7 \u8bbe\u8ba1\u65b9\u6848<\/h3>\n  <p>\u4f9d\u636e\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b\uff08GB 50736-2012\uff09\uff0c\u7ed3\u5408\u6210\u90fd\u5730\u533a\u590f\u5b63\u7a7a\u8c03\u5ba4\u5916\u8ba1\u7b97\u5e72\u7403\u6e29\u5ea632.5\u2103\uff0c\u5367\u5ba4\u6309200W\/\u33a1\u3001\u5ba2\u9910\u5385\u6309250W\/\u33a1\u3001\u53a8\u623f\u6309300W\/\u33a1\u4f30\u7b97\u51b7\u8d1f\u8377\u3002<\/p>\n\n  <div class=\"lm-flip-card lm-load-flip\" onclick=\"this.classList.toggle('flipped')\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front lm-load-front\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg\" alt=\"\u7a7a\u8c03\u8bbe\u8ba1\u65b9\u6848\u6837\u56fe\">\n        <div class=\"lm-load-cap\">\u7a7a\u8c03\u8bbe\u8ba1\u65b9\u6848\u6837\u56fe<span>\u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u8d1f\u8377\u5206\u6790\u8868 \u21bb<\/span><\/div>\n      <\/div>\n      <div class=\"lm-flip-back\">\n        <h4>\u51b7\u8d1f\u8377\u5206\u6790\u8868<\/h4>\n  <table>\n    <thead>\n      <tr>\n        <th>\u533a\u57df<\/th>\n        <th>\u9762\u79ef(\u33a1)<\/th>\n        <th>\u5355\u4f4d\u8d1f\u8377(W\/\u33a1)<\/th>\n        <th>\u603b\u8d1f\u8377(W)<\/th>\n        <th>\u6298\u5408HP<\/th>\n        <th>\u65b9\u6848A\u9009\u578b<\/th>\n        <th>\u65b9\u6848B\u9009\u578b<\/th>\n        <th>\u65b9\u6848C\u9009\u578b<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td>\u4e3b\u5367<\/td>\n        <td>28.42<\/td>\n        <td>200<\/td>\n        <td>5,684<\/td>\n        <td>2.0HP<\/td>\n        <td>RPIZ-50 (5.0kW)<\/td>\n        <td>RPIZ-50 (5.0kW)<\/td>\n        <td>RFP-85 (8.5kW)<\/td>\n      <\/tr>\n      <tr>\n        <td>\u6b21\u53671<\/td>\n        <td>17.45<\/td>\n        <td>200<\/td>\n        <td>3,490<\/td>\n        <td>1.25HP<\/td>\n        <td>RPIZ-32 (3.2kW)<\/td>\n        <td>RPIZ-32 (3.2kW)<\/td>\n        <td>RFP-51 (5.1kW)<\/td>\n      <\/tr>\n      <tr>\n        <td>\u4e66\u623f<\/td>\n        <td>11.62<\/td>\n        <td>200<\/td>\n        <td>2,324<\/td>\n        <td>0.8HP<\/td>\n        <td>RPIZ-18 (1.8kW)<\/td>\n        <td>RPIZ-18 (1.8kW)<\/td>\n        <td>RFP-34 (3.4kW)<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5ba2\u9910\u5385<\/td>\n        <td>82.54<\/td>\n        <td>250<\/td>\n        <td>20,635<\/td>\n        <td>7.3HP<\/td>\n        <td>RPIZ-71+63 (13.4kW)<\/td>\n        <td>RPIZ-71+63 (13.4kW)<\/td>\n        <td>RFP-156+136 (29.2kW)<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5973\u513f\u623f\u95f4<\/td>\n        <td>15.11<\/td>\n        <td>200<\/td>\n        <td>3,022<\/td>\n        <td>1.0HP<\/td>\n        <td>RPIZ-25 (2.5kW)<\/td>\n        <td>RPIZ-25 (2.5kW)<\/td>\n        <td>RFP-51 (5.1kW)<\/td>\n      <\/tr>\n      <tr>\n        <td>\u53a8\u623f<\/td>\n        <td>9.67<\/td>\n        <td>300<\/td>\n        <td>2,901<\/td>\n        <td>1.0HP<\/td>\n        <td>RCIS-22 (2.2kW)<\/td>\n        <td>RCIS-22 (2.2kW)<\/td>\n        <td>\u2014<\/td>\n      <\/tr>\n      <tr class=\"lm-total-row\">\n        <td>\u5408\u8ba1<\/td>\n        <td>164.81<\/td>\n        <td>\u2014<\/td>\n        <td>38,056<\/td>\n        <td>13.4HP<\/td>\n        <td>28.1kW<\/td>\n        <td>28.1kW<\/td>\n        <td>\u2014<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n  <p><span class=\"lm-badge lm-badge-info\">\u8bf4\u660e<\/span> \u7a7a\u8c03\u9762\u79ef\u7ea6165\u33a1\uff0c\u5730\u6696\u9762\u79ef170.9\u33a1\u3002\u65b9\u6848A\u4e66\u623f\u9009\u752818\u578b\u5185\u673a\uff081.8kW\uff09\uff0c\u5339\u914d11.62\u33a1\u4e66\u623f\u9762\u79ef\uff0c\u9009\u578b\u5408\u7406\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n  <div class=\"lm-flip-hint\">\ud83d\udca1 \u70b9\u51fb\u5361\u7247\u53ef\u7ffb\u8f6c\uff1a\u6b63\u9762\u8bbe\u8ba1\u65b9\u6848\u6837\u56fe \u21c4 \u80cc\u9762\u8d1f\u8377\u5206\u6790\u8868<\/div>\n\n<\/section>\n\n<section id=\"s2\">\n  <h2>S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/h2>\n\n  <h3>\u56db\u5927\u75db\u70b9\u8bca\u65ad<\/h3>\n  <div class=\"lm-pain-grid\">\n    <div class=\"lm-pain-card core\">\n      <div class=\"lm-pain-icon\">\u2744\ufe0f<\/div>\n      <span class=\"tag\">\u6838\u5fc3\u75db\u70b9<\/span>\n      <h4>\u6c1f\u673a\"\u8d8a\u5439\u8d8a\u51b7\"<\/h4>\n      <p><strong>\u73b0\u623f\uff1a<\/strong>\u683c\u529b\u6c1f\u673a\u51fa\u98ce7-10\u2103\uff0c\u5439\u4e45\u4e86\u4e0d\u8212\u670d\u3002<\/p>\n      <p><strong>\u6839\u56e0\uff1a<\/strong>\u51b7\u5a92\u76f4\u63a5\u8fdb\u5ba4\u5185\u84b8\u53d1\u5668\uff0c\u51fa\u98ce\u6e29\u5ea6\u4f4e\u3001\u6e29\u5dee\u5927\uff08\u5ba4\u6e2927\u2103\u2192\u51fa\u98ce7\u2103\uff0c\u6e29\u5dee20\u2103\uff09\u3002<\/p>\n      <div class=\"solution\"><strong>\u65b0\u65b9\u6848\uff1a<\/strong>\u65b9\u6848A\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff1b\u65b9\u6848C\u5929\u6c34\u5730\u6c34\u51fa\u98ce15-17\u2103\u67d4\u548c\u3002<\/div>\n    <\/div>\n    <div class=\"lm-pain-card important\">\n      <div class=\"lm-pain-icon\">\ud83d\udd07<\/div>\n      <span class=\"tag\">\u91cd\u8981<\/span>\n      <h4>\u566a\u97f3\"\u6709\u70b9\u5927\"<\/h4>\n      <p><strong>\u73b0\u623f\uff1a<\/strong>\u73b0\u623f\u6c1f\u673a\u8fd0\u884c\u566a\u97f3\u660e\u663e\u3002<\/p>\n      <p><strong>\u6839\u56e0\uff1a<\/strong>\u53ef\u80fd\u4e0e\u5b89\u88c5\u5de5\u827a\u6709\u5173\uff1a\u5185\u673a\u51cf\u9707\u4e0d\u5230\u4f4d\u3001\u98ce\u7ba1\u8bbe\u8ba1\u4e0d\u5408\u7406\u3001\u6216\u673a\u578b\u672c\u8eab\u566a\u97f3\u504f\u9ad8\u3002<\/p>\n      <div class=\"solution\"><strong>\u65b0\u65b9\u6848\uff1a<\/strong>\u9009\u7528\u4f4e\u566a\u97f3\u5185\u673a\uff08\u226435dB\uff09\uff0c\u4e25\u683c\u6267\u884c\u51cf\u9707\u5b89\u88c5\u5de5\u827a\uff0c\u5916\u673a\u4f4d\u907f\u8ba9\u5367\u5ba4\u3002<\/div>\n    <\/div>\n    <div class=\"lm-pain-card core\">\n      <div class=\"lm-pain-icon\">\ud83d\udd25<\/div>\n      <span class=\"tag\">\u6838\u5fc3\u75db\u70b9<\/span>\n      <h4>\u5730\u6696\u65e0\u8054\u52a8\u63a7\u5236<\/h4>\n      <p><strong>\u73b0\u623f\uff1a<\/strong>\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u65e0\u8054\u52a8\uff0c\u9505\u7089\u9891\u7e41\u542f\u505c\u505a\u65e0\u6548\u529f\u3002<\/p>\n      <p><strong>\u6839\u56e0\uff1a<\/strong>\u65e0\u5ba4\u5185\u6e29\u63a7\u5668\u8054\u52a8\uff0c\u9505\u7089\u9760\u56de\u6c34\u6e29\u5ea6\u81ea\u884c\u5224\u65ad\uff0c\u5ba4\u6e29\u5df2\u8fbe\u6807\u4f46\u9505\u7089\u4ecd\u5728\u70e7\u3002<\/p>\n      <div class=\"solution\"><strong>\u65b0\u65b9\u6848\uff1a<\/strong>\u914d\u7f6e\u5ba4\u5185\u6e29\u63a7\u5668+\u8054\u52a8\u6a21\u5757\uff0c\u5ba4\u6e29\u8fbe\u6807\u901a\u77e5\u9505\u7089\u505c\u6b62\uff0c\u4e3b\u7ba1\u752840\u7ba1\u786e\u4fdd\u6d41\u91cf\u3002<\/div>\n    <\/div>\n    <div class=\"lm-pain-card normal\">\n      <div class=\"lm-pain-icon\">\ud83c\udf73<\/div>\n      <span class=\"tag\">\u9700\u6c42<\/span>\n      <h4>\u53a8\u623f\u590f\u5929\u505a\u996d\u70ed<\/h4>\n      <p><strong>\u73b0\u623f\uff1a<\/strong>\u65e0\u53a8\u623f\u7a7a\u8c03\uff0c\u590f\u5929\u505a\u996d\u95f7\u70ed\u3002<\/p>\n      <p><strong>\u6839\u56e0\uff1a<\/strong>\u53a8\u623f\u6709\u7076\u5177\u70ed\u6e90+\u897f\u6652\u53ef\u80fd\u6027\uff0c\u65e0\u7a7a\u8c03\u65f6\u4f53\u611f\u6e29\u5ea6\u53ef\u8fbe35\u2103+\u3002<\/p>\n      <div class=\"solution\"><strong>\u65b0\u65b9\u6848\uff1a<\/strong>\u65b9\u6848A\/B\u914d\u7f6eRCIS-22FSCN1QD\u53a8\u623f\u4e13\u7528\u5185\u673a\uff08\u9632\u6cb9\u6c61\u8bbe\u8ba1\uff09\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-warn-line\">\n    <strong>\u73b0\u623f\u4f7f\u7528\u6570\u636e\u53c2\u8003\uff1a<\/strong>\u5730\u6696\u6708\u5747\u7ea6700\u5143\/\u6708\uff08\u542b\u751f\u6d3b\u7528\u6c14\uff09\uff0c\u4e24\u4e2a\u6708\u6700\u9ad81300+\u5143\uff0c\u5ba4\u5185\u6e29\u5ea622-23\u2103\uff0c\u5f00\u542f\u65f6\u95f411\u6708-3\u6708\u7ea65\u4e2a\u6708\u3002\u65b0\u65b9\u6848\u901a\u8fc7\u8054\u52a8\u63a7\u5236+40\u4e3b\u7ba1+\u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c\uff0c\u9884\u8ba1\u53ef\u964d\u4f4e15-25%\u71c3\u6c14\u8d39\u7528\u3002\n  <\/div>\n\n  <h3 id=\"s2-constraint\">\u9690\u6027\u7269\u7406\u7ea6\u675f\uff08\u5fc5\u987b\u91cd\u89c6\u7684\u5de5\u7a0b\u7ea2\u7ebf\uff09<\/h3>\n  <div class=\"lm-pain-grid\">\n    <div class=\"lm-pain-card core\">\n      <div class=\"lm-pain-icon\">\ud83d\udeab<\/div>\n      <span class=\"tag\">\u7ea2\u7ebf1<\/span>\n      <h4>\u4e3b\u7ba1\u5fc5\u987b\u752840\u7ba1<\/h4>\n      <p>260\u33a1\u5927\u5e73\u5c42\u3001\u5730\u6696\u9762\u79ef170.9\u33a1\uff0c25\u7ba1\u6d41\u91cf\u4e0d\u591f\u3002\u5982\u679c\u752825\u4e3b\u7ba1\uff0c\u9505\u7089\u53ea\u80fd\u9760\u63d0\u9ad8\u6c34\u6e29\u6765\u51d1\u6d41\u91cf\u2014\u2014\u51b7\u51dd\u7089\u88ab\u8feb\u53d8\u6210\u9ad8\u6e29\u7089\u70e7\uff0c<strong>\u8282\u80fd\u4f18\u52bf\u5168\u90e8\u4e27\u5931<\/strong>\u3002<\/p>\n      <div class=\"solution\"><strong>\u8981\u6c42\uff1a<\/strong>40\u4e3b\u7ba1\u786e\u4fdd\u8db3\u591f\u6d41\u91cf\uff0c\u51b7\u51dd\u7089\u624d\u80fd\u5728\u4f4e\u6e29\u5de5\u51b5\uff0840-50\u2103\u4f9b\u6c34\uff09\u4e0b\u9ad8\u6548\u8fd0\u884c\u3002\u8be6\u89c1<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?p=1337\" target=\"_blank\">\u8f85\u6750\u914d\u7f6e\u6807\u51c6<\/a>\u3002<\/div>\n    <\/div>\n    <div class=\"lm-pain-card core\">\n      <div class=\"lm-pain-icon\">\ud83d\udd17<\/div>\n      <span class=\"tag\">\u7ea2\u7ebf2<\/span>\n      <h4>\u5fc5\u987b\u505a\u8054\u52a8\u63a7\u5236<\/h4>\n      <p>\u6bcf\u4e2a\u91c7\u6696\u533a\u57df\u914d\u7f6e\u5ba4\u5185\u6e29\u63a7\u5668\uff0c\u901a\u8fc7\u8054\u52a8\u6a21\u5757\u4e0e\u9505\u7089\u901a\u4fe1\u3002\u5ba4\u5185\u6e29\u5ea6\u8fbe\u5230\u8bbe\u5b9a\u503c\u540e\uff0c\u6e29\u63a7\u5668\u901a\u77e5\u9505\u7089\u505c\u6b62\u8f93\u51fa\u2014\u2014\u8fd9\u662f\u89e3\u51b3\"\u9505\u7089\u9891\u7e41\u542f\u505c\u505a\u65e0\u6548\u529f\"\u75db\u70b9\u7684\u6838\u5fc3\u63aa\u65bd\u3002<\/p>\n      <div class=\"solution\"><strong>\u8981\u6c42\uff1a<\/strong>\u5fc5\u987b\u505a\u8054\u52a8\u63a7\u5236\u3002\u4e0d\u505a\u8054\u52a8 = \u51b7\u51dd\u7089\u767d\u4e70\uff0c\u8282\u80fd\u6548\u679c\u5f52\u96f6\u3002<\/div>\n    <\/div>\n    <div class=\"lm-pain-card core\">\n      <div class=\"lm-pain-icon\">\u26a0\ufe0f<\/div>\n      <span class=\"tag\">\u7ea2\u7ebf3<\/span>\n      <h4>\u8b66\u60d5\"\u7280\u725b\u738b\"\u98ce\u76d8\u62fc\u51d1\u7cfb\u7edf<\/h4>\n      <p>\"\u7280\u725b\u738b\"\u98ce\u76d8\u662f\u7b2c\u4e09\u65b9\u62fc\u51d1\u7cfb\u7edf\uff0c<strong>\u6ca1\u6709\u5382\u5bb6\u6574\u4f53\u80cc\u4e66<\/strong>\u3002\u5916\u673a\u3001\u98ce\u76d8\u3001\u63a7\u5236\u5668\u54c1\u724c\u6df7\u6742\u2014\u2014\u51fa\u4e86\u95ee\u9898\u4e92\u76f8\u63a8\u8bff\uff0c\u7ef4\u4fdd\u53ef\u80fd\u627e\u4e0d\u5230\u4eba\u8d1f\u8d23\u3002<\/p>\n      <div class=\"solution\"><strong>\u8981\u6c42\uff1a<\/strong>\u575a\u6301<strong>\u5382\u5bb6\u539f\u5382\u6574\u5957\u7cfb\u7edf<\/strong>\uff08\u65e5\u7acb\u5916\u673a+\u65e5\u7acb\u5185\u673a+\u65e5\u7acb\u63a7\u5236\u5668\uff09\uff0c\u4e00\u4f53\u5316\u8d28\u4fdd\u3002\u8be6\u89c1<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?p=886\" target=\"_blank\">\u907f\u5751\u6307\u5357<\/a>\u3002<\/div>\n    <\/div>\n    <div class=\"lm-pain-card important\">\n      <div class=\"lm-pain-icon\">\u2705<\/div>\n      <span class=\"tag\">\u63d0\u91924<\/span>\n      <h4>\u65b9\u6848A\u8d85\u914d\u7387\u5b89\u5168<\/h4>\n      <p>\u65b9\u6848A\u5916\u673aRAS-224FSXPN5Q\uff0822.4kW\uff09\u914d\u5185\u673a\u603b\u8ba128.1kW\uff0c\u8d85\u914d\u7387<strong>125.4%<\/strong>\uff0c\u5728\u65e5\u7acb\u6807\u51c6130%\u4e0a\u9650\u4ee5\u5185\u3002<\/p>\n      <div class=\"solution\"><strong>\u7ed3\u8bba\uff1a<\/strong>\u5e38\u4f4f4\u4eba\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u5b9e\u9645\u8fd0\u884c\u538b\u529b\u53ef\u63a7\uff0c\u9009\u578b\u5408\u7406\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s2-compare\">\u6c34\u673a vs \u6c1f\u673a \u6838\u5fc3\u5bf9\u6bd4<\/h3>\n  <p>\u5f88\u591a\u5ba2\u6237\u4ee5\u4e3a\u6c34\u673a\u548c\u6c1f\u673a\u662f\u4e24\u79cd\u5b8c\u5168\u4e0d\u540c\u7684\u6280\u672f\uff0c\u5176\u5b9e<strong>\u672c\u8d28\u76f8\u540c\u2014\u2014\u90fd\u662f\u70ed\u6cf5\u7a7a\u6c14\u80fd<\/strong>\u3002\u533a\u522b\u53ea\u5728\u590f\u5929\u7684\u672b\u7aef\u5f62\u5f0f\uff1a\u6c1f\u76f4\u63a5\u8fdb\u5c4b vs \u6c34\u901a\u8fc7\u4e2d\u8f6c\u7ad9\u6362\u70ed\u540e\u8fdb\u5c4b\u3002\u51ac\u5929\u91c7\u6696\u5219\u90fd\u662f\u7528\u6c34\u8fdb\u5730\u6696\u7ba1\u3002<\/p>\n\n  <div class=\"lm-chart-wrap\">\n    <h4 style=\"text-align:center;\">\u6c34\u673a vs \u6c1f\u673a \u591a\u7ef4\u5ea6\u80fd\u529b\u96f7\u8fbe\u56fe\uff085\u5206\u5236\uff09<\/h4>\n    <div class=\"lm-radar-canvas\">\n      <canvas id=\"waterVsFreonChart\"><\/canvas>\n    <\/div>\n    <p style=\"text-align:center; font-size:13px; color:var(--text-light); margin-top:10px;\">\u70b9\u51fb\u56fe\u4f8b\u53ef\u9690\u85cf\/\u663e\u793a\u5bf9\u5e94\u66f2\u7ebf\u3002\u6c34\u673a\u5728\u8212\u9002\u5ea6\u4e0e\u4f53\u611f\u67d4\u548c\u5ea6\u5360\u4f18\uff1b\u6c1f\u673a\u5728\u964d\u6e29\u901f\u5ea6\u4e0e\u9664\u6e7f\u5f3a\u5ea6\u5360\u4f18\u3002<\/p>\n  <\/div>\n\n  <div class=\"lm-two-col\" style=\"margin-top:20px;\">\n    <div>\n      <h4>\u6c1f\u673a\uff08\u76f4\u63a5\u84b8\u53d1\uff09<\/h4>\n      <ul>\n        <li><strong>\u539f\u7406\uff1a<\/strong>\u51b7\u5a92\u76f4\u63a5\u8fdb\u5165\u5ba4\u5185\u673a\u84b8\u53d1\u5668\u6362\u70ed<\/li>\n        <li><strong>\u51fa\u98ce\u6e29\u5ea6\uff1a<\/strong>7-10\u2103<\/li>\n        <li><strong>\u964d\u6e29\u901f\u5ea6\uff1a<\/strong>\u5feb\uff085-10\u5206\u949f\u89c1\u6548\uff09<\/li>\n        <li><strong>\u4f53\u611f\uff1a<\/strong>\u6e29\u5dee\u5927\uff08\u5ba4\u6e2927\u2103\u2192\u51fa\u98ce7\u2103\uff0c\u6e29\u5dee20\u2103\uff09\uff0c\u5439\u5728\u8eab\u4e0a\"\u751f\u51b7\"<\/li>\n        <li><strong>\u9664\u6e7f\uff1a<\/strong>\u9664\u6e7f\u91cf\u5927\uff0c\u53ef\u80fd\u8fc7\u5ea6\u5e72\u71e5<\/li>\n        <li><strong>\u9002\u5408\uff1a<\/strong>\u8ffd\u6c42\u5feb\u901f\u964d\u6e29\u3001\u4e0d\u5728\u610f\u4f53\u611f\u7684\u573a\u666f<\/li>\n        <li><strong>\u54c1\u724c\uff1a<\/strong>\u65e5\u7acb\u3001\u5927\u91d1\u3001\u683c\u529b\u3001\u7f8e\u7684\u7b49<\/li>\n      <\/ul>\n    <\/div>\n    <div>\n      <h4>\u6c34\u673a\uff08\u4e8c\u6b21\u6362\u70ed\uff09<\/h4>\n      <ul>\n        <li><strong>\u539f\u7406\uff1a<\/strong>\u51b7\u5a92\u5148\u6362\u70ed\u7ed9\u6c34\uff0c\u6c34\u518d\u901a\u8fc7\u98ce\u76d8\u6362\u70ed\u7ed9\u7a7a\u6c14<\/li>\n        <li><strong>\u51fa\u98ce\u6e29\u5ea6\uff1a<\/strong>15-17\u2103<\/li>\n        <li><strong>\u964d\u6e29\u901f\u5ea6\uff1a<\/strong>\u8f83\u6162\uff0810-15\u5206\u949f\u89c1\u6548\uff09<\/li>\n        <li><strong>\u4f53\u611f\uff1a<\/strong>\u6e29\u5dee\u5c0f\uff08\u5ba4\u6e2927\u2103\u2192\u51fa\u98ce15\u2103\uff0c\u6e29\u5dee12\u2103\uff09\uff0c\u67d4\u548c\u81ea\u7136<\/li>\n        <li><strong>\u9664\u6e7f\uff1a<\/strong>\u6e29\u548c\u9664\u6e7f\uff0c\u4e0d\u8fc7\u5ea6\u5e72\u71e5<\/li>\n        <li><strong>\u9002\u5408\uff1a<\/strong>\u6709\u5c0f\u5b69\/\u8001\u4eba\u3001\u957f\u65f6\u95f4\u5f00\u542f\u3001\u8ffd\u6c42\u8212\u9002\u5ea6\u7684\u5bb6\u5ead<\/li>\n        <li><strong>\u54c1\u724c\uff1a<\/strong>\u65e5\u7acb\u6c34\u5885\u9002\u3001\u96f6\u8d8aDBT\u7b49<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-geo-card\">\n    <h4>\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34 \u6838\u5fc3\u533a\u522b<\/h4>\n    <p><strong>\u51ac\u5929\u91c7\u6696\uff1a<\/strong>\u4e24\u8005\u5b8c\u5168\u4e00\u6837\u2014\u2014\u90fd\u662f\u7528\u6c34\u8fdb\u5730\u6696\u7ba1\uff0c\u65e0\u533a\u522b\u3002<\/p>\n    <p><strong>\u590f\u5929\u5236\u51b7\u672b\u7aef\u4e0d\u540c\uff1a<\/strong><\/p>\n    <ul>\n      <li><strong>\u5929\u6c34\u5730\u6c34\uff1a<\/strong>\u590f\u5929\u7528\u6c34\u98ce\u76d8\uff08\u6c34\u6e297-12\u2103\uff09\uff0c\u51fa\u98ce15-17\u2103\u67d4\u548c<\/li>\n      <li><strong>\u5929\u6c1f\u5730\u6c34\uff1a<\/strong>\u590f\u5929\u7528\u6c1f\u7cfb\u7edf\u5ba4\u5185\u673a\uff08\u51b7\u5a92\u76f4\u63a5\u84b8\u53d1\uff09\uff0c\u51fa\u98ce7-10\u2103\u5feb\u51b7\uff1b\u4f46\u4e09\u7ba1\u5236\u5c0a\u777f\u5168\u6548\u53ef\u5b9e\u73b0\u6e29\u6e7f\u53cc\u63a7\uff0c\u8212\u9002\u5ea6\u548c\u6c34\u673a\u76f8\u5f53\uff0c\u4e14\u6e7f\u5ea6\u7cbe\u51c6\u63a7\u5236\u4f18\u52bf\u7a81\u51fa<\/li>\n    <\/ul>\n    <p><strong>\u8463\u5148\u751f\u7684\u6838\u5fc3\u8bc9\u6c42\u662f\"\u4e0d\u4f1a\u8d8a\u5439\u8d8a\u51b7\"<\/strong>\u2014\u2014\u5929\u6c34\u5730\u6c34\uff08\u65b9\u6848C\uff09\u6700\u76f4\u63a5\u6ee1\u8db3\u8fd9\u4e2a\u9700\u6c42\uff1b\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\uff08\u65b9\u6848A\uff09\u901a\u8fc7\u6e29\u6e7f\u53cc\u63a7\uff0c\u8212\u9002\u5ea6\u548c\u6c34\u673a\u76f8\u5f53\uff1b\u8212\u4eab\u6c1f\u673a\uff08\u65b9\u6848B\uff09\u642d\u8f7d\u65e5\u7acb\u4e94\u7ef4\u4e00\u4f53\u68c0\u6d4b\u6e29\u5ea6\u6280\u672f\uff0c\u8212\u9002\u5ea6\u6bd4\u5176\u4ed6\u54c1\u724c\u66f4\u9ad8\uff0c\u6027\u4ef7\u6bd4\u6700\u9ad8\u3002<\/p>\n  <\/div>\n\n  <p>\u4e86\u89e3\u66f4\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u8bf7\u8bbf\u95ee\u9f99\u8109\u6696\u901a<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?p=2705\" target=\"_blank\">\u65b9\u6848\u4e2d\u5fc3<\/a>\u3002<\/p>\n<\/section>\n\n<section id=\"s3\">\n  <h2>S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4<\/h2>\n\n  <h3>\u7a7a\u8c03\u4e09\u65b9\u6848\u6982\u89c8<\/h3>\n  <table>\n    <thead>\n      <tr>\n        <th>\u7ef4\u5ea6<\/th>\n        <th>\u65b9\u6848A \u00b7 \u5929\u6c1f\u5730\u6c342\u8054\u4f9b<\/th>\n        <th>\u65b9\u6848B \u00b7 \u8212\u4eab\u6c1f\u673a2\u62d67<\/th>\n        <th>\u65b9\u6848C \u00b7 \u5929\u6c34\u5730\u6c342\u8054\u4f9b<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td>\u7cfb\u7edf\u7c7b\u578b<\/td>\n        <td>\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/td>\n        <td>\u4f20\u7edf\u6c1f\u673a\u591a\u8054\u673a<\/td>\n        <td>\u5929\u6c34\u5730\u6c34\u5168\u6c34\u7cfb\u7edf<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5916\u673a\u578b\u53f7<\/td>\n        <td>RAS-224FSXPN5Q<br>RWMG-224FWXNZQ<\/td>\n        <td>RAS-125HRNAQ<br>RAS-140HRNAQ<\/td>\n        <td>RAS-180FPUEN2Q\/M<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5916\u673a\u5bb9\u91cf<\/td>\n        <td>22.4kW\uff08SET-FREE\u53cc\u8f6c\u5b50\uff09<\/td>\n        <td>12.5kW + 14.0kW = 26.5kW<\/td>\n        <td>18.0kW\uff08\u53cc\u8f6c\u5b50\u53cc\u98ce\u6247\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5185\u673a\u7cfb\u5217<\/td>\n        <td>RPIZ-FSVN2QB\uff08\u5c0a\u777f\u5168\u6548\uff09<\/td>\n        <td>RPIZ-FSNAQD\uff08\u8212\u4eab\uff09<\/td>\n        <td>RFP-WAR\/DBT\uff08\u96f6\u8d8a\u6c34\u98ce\u76d8\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5185\u673a\u6570\u91cf<\/td>\n        <td>7\u53f0\uff08\u542b\u53a8\u623f\u4e13\u7528\u673a\uff09<\/td>\n        <td>7\u53f0\uff08\u542b\u53a8\u623f\u4e13\u7528\u673a\uff09<\/td>\n        <td>6\u53f0\uff08\u53a8\u623f\u4e0d\u88c5\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td>\u63a7\u5236\u5668<\/td>\n        <td>7\u53f0PC-P1HPQA(\u9ad8\u6e05\u5f69\u5c4f)<br>\u9762\u4ef7476\u00d77=3,332 8.5\u6298=2,832<br>+1\u53f0PC-WMH3Q(\u6c34\u6a21\u5757) \u9762\u4ef7300 8.5\u6298=255<br>\u2192\u5408\u8ba18.5\u6298 <strong>3,087\u5143<\/strong><\/td>\n        <td>6\u53f0PC-P1HVQA(WiFi\u7ebf\u63a7\u5668)<br>\u9762\u4ef7200\u00d76=1,200 8\u6298=960<br>\u53a8\u623f\u673aRCIS-22\u81ea\u5e26\u63a7\u5236\u5668<br>\u2192\u5408\u8ba18\u6298 <strong>960\u5143<\/strong><\/td>\n        <td>6\u53f0SXC-TE01(\u6c34\u6e29\u63a7\u5236\u5668)<br>\u96f6\u552e\u4ef7375\u00d76=<strong>2,250\u5143<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td>\u6298\u6263<\/td>\n        <td><span class=\"lm-pill lm-pill-blue\">8.5\u6298<\/span><\/td>\n        <td><span class=\"lm-pill lm-pill-blue\">8\u6298<\/span><\/td>\n        <td><span class=\"lm-pill lm-pill-gray\">\u96f6\u552e\u4ef7\u4e0d\u6253\u6298<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u8d85\u914d\u7387<\/td>\n        <td><span class=\"lm-pill lm-pill-green\">125.4%\uff08\u5b89\u5168\uff09<\/span><\/td>\n        <td><span class=\"lm-pill lm-pill-green\">103.2% + 108.6%<\/span><\/td>\n        <td>\u2014<\/td>\n      <\/tr>\n      <tr>\n        <td>\u5730\u6696\u529f\u80fd<\/td>\n        <td>\u81ea\u5e26\uff08\u6c34\u6a21\u5757\u5e26\u5730\u6696\uff09<\/td>\n        <td>\u65e0\uff08\u9700\u72ec\u7acb\u5730\u6696\uff09<\/td>\n        <td>\u81ea\u5e26\uff08\u6c34\u673a\u5e26\u5730\u6696\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td>\u590f\u5929\u51fa\u98ce\u6e29\u5ea6<\/td>\n        <td>7-10\u2103\uff08\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff09<\/td>\n        <td>7-10\u2103\uff08\u6807\u51c6\u6c1f\u673a\uff09<\/td>\n        <td><span class=\"lm-pill lm-pill-green\">15-17\u2103\uff08\u67d4\u548c\uff09<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u8212\u9002\u5ea6\u8bc4\u7ea7<\/td>\n        <td><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2606<\/span><\/td>\n        <td><span class=\"lm-stars\">\u2605\u2605\u2605\u2606\u2606<\/span><\/td>\n        <td><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u7a7a\u8c03\u603b\u8ba1<\/td>\n        <td><strong>76,249\u5143 \u2248 7.62\u4e07<\/strong><\/td>\n        <td><strong>52,160\u5143 \u2248 5.22\u4e07<\/strong><\/td>\n        <td><strong>77,355\u5143 \u2248 7.74\u4e07<br>+\u5730\u6696\u7ba1\u8def3\u4e07<\/strong><\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"lm-pcard\" id=\"s3-a\">\n    <span class=\"lm-scheme-tag lm-tag-a\">\u65b9\u6848A \u00b7 \u5929\u6c1f\u5730\u6c342\u8054\u4f9b\uff08\u5c0a\u777f\u5168\u65488.5\u6298\uff09<\/span>\n    <h3>\u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u00b7 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf<\/h3>\n\n    <div class=\"lm-product-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM\u5c0a\u777f\u5168\u6548-II02.jpg\" alt=\"\u65e5\u7acb\u5c0a\u777f\u5168\u6548II\u5ba4\u5916\u673a\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n      <div class=\"lm-product-info\">\n        <h4>\u65e5\u7acb\u5c0a\u777f\u5168\u6548II \u2014 \u884c\u4e1a\u9996\u6b3e\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u4e2d\u592e\u7a7a\u8c03<\/h4>\n        <p>\u642d\u8f7d\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u6280\u672f\uff0c\u5236\u51b7\u3001\u9664\u6e7f\u3001\u52a0\u6e7f\u53ef\u72ec\u7acb\u8fd0\u884c\uff1b\u590f\u5b63\u9ad8\u6e29\u9ad8\u6e7f\u5929\u6c14\u4e5f\u80fd\u4fdd\u6301\u5e72\u723d\u4e0d\u9634\u51b7\uff0c\u51ac\u5b63\u6c34\u6a21\u5757\u5e26\u5730\u6696\u65e0\u9700\u9505\u7089\u3002<\/p>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\u67e5\u770b\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-pcard-summary\">\n      <span class=\"lm-badge lm-badge-info\">\u5916\u673a\uff1aRAS-224FSXPN5Q<\/span>\n      <span class=\"lm-badge lm-badge-info\">\u6c34\u6a21\u5757\uff1aRWMG-224FWXNZQ<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u8d85\u914d\u7387\uff1a125.4%<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u6298\u6263\uff1a8.5\u6298<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u7a7a\u8c03\u603b\u8ba1\uff1a76,249\u5143<\/span>\n    <\/div>\n\n    <h4>\u5916\u673a+\u6c34\u6a21\u5757<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u8bbe\u5907<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u5bb9\u91cf<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n          <th>8.5\u6298(\u5143)<\/th>\n          <th>\u5b89\u88c5\u8d39(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a<\/td>\n          <td>RAS-224FSXPN5Q<\/td>\n          <td>22.4kW SET-FREE\u53cc\u8f6c\u5b50<\/td>\n          <td>29,300<\/td>\n          <td>24,905<\/td>\n          <td>600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757<\/td>\n          <td>RWMG-224FWXNZQ<\/td>\n          <td>\u5730\u6696\u6c34\u6362\u70ed\u6a21\u5757<\/td>\n          <td>9,750<\/td>\n          <td>8,288<\/td>\n          <td>625<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h4>\u5185\u673a\u914d\u7f6e\uff087\u53f0\uff09<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u533a\u57df<\/th>\n          <th>\u9762\u79ef(\u33a1)<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u5bb9\u91cf(kW)<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n          <th>8.5\u6298(\u5143)<\/th>\n          <th>\u5b89\u88c5\u8d39(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e3b\u5367<\/td>\n          <td>28.42<\/td>\n          <td>RPIZ-50FSVN2QB\/PC<\/td>\n          <td>5.0<\/td>\n          <td>5,663<\/td>\n          <td>4,814<\/td>\n          <td>1,900<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6b21\u53671<\/td>\n          <td>17.45<\/td>\n          <td>RPIZ-32FSVN2QB\/PC<\/td>\n          <td>3.2<\/td>\n          <td>5,238<\/td>\n          <td>4,452<\/td>\n          <td>1,900<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e66\u623f<\/td>\n          <td>11.62<\/td>\n          <td>RPIZ-18FSVN2QB\/PC<\/td>\n          <td>1.8<\/td>\n          <td>4,825<\/td>\n          <td>4,101<\/td>\n          <td>1,900<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba2\u9910\u5385<\/td>\n          <td>82.54<\/td>\n          <td>RPIZ-71FSVN2QB\/PC<\/td>\n          <td>7.1<\/td>\n          <td>5,825<\/td>\n          <td>4,961<\/td>\n          <td>1,900<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba2\u9910\u5385<\/td>\n          <td>82.54<\/td>\n          <td>RPIZ-63FSVN2QB\/PC<\/td>\n          <td>6.3<\/td>\n          <td>5,825<\/td>\n          <td>4,961<\/td>\n          <td>1,900<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5973\u513f\u623f\u95f4<\/td>\n          <td>15.11<\/td>\n          <td>RPIZ-25FSVN2QB\/PC<\/td>\n          <td>2.5<\/td>\n          <td>5,050<\/td>\n          <td>4,293<\/td>\n          <td>1,900<\/td>\n        <\/tr>\n        <tr>\n          <td>\u53a8\u623f<\/td>\n          <td>9.67<\/td>\n          <td>RCIS-22FSCN1QD<\/td>\n          <td>2.2<\/td>\n          <td>6,175<\/td>\n          <td>5,249<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h4>\u8d39\u7528\u6c47\u603b<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u660e\u7ec6<\/th>\n          <th>\u91d1\u989d(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u6298\u540e\u8bbe\u5907\u5408\u8ba1<\/td>\n          <td>\u5916\u673a24,905 + \u6c34\u6a21\u57578,288 + 7\u53f0\u5185\u673a33,544<\/td>\n          <td>62,737<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5b89\u88c5\u8d39\u5408\u8ba1<\/td>\n          <td>\u5916\u673a600 + \u6c34\u6a21\u5757625 + 6\u53f0\u00d71,900 + \u53a8\u623f1,600<\/td>\n          <td>14,225<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td>\u65b9\u6848A\u7a7a\u8c03\u603b\u8ba1<\/td>\n          <td>\u8bbe\u5907 + \u5b89\u88c5<\/td>\n          <td>76,249 \u2248 7.62\u4e07<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"lm-warn-line\">\n      <strong>\u8d85\u914d\u7387\u8bf4\u660e\uff1a<\/strong>\u5916\u673a22.4kW \u00f7 \u5185\u673a\u603b\u8ba128.1kW = <strong>125.4%<\/strong>\uff0c\u5728\u65e5\u7acb\u6807\u51c6130%\u4e0a\u9650\u4ee5\u5185\uff0c\u9009\u578b\u5408\u7406\u3002\u4e66\u623f\u9009\u752818\u578b\u5185\u673a\uff081.8kW\uff09\uff0c\u5339\u914d11.62\u33a1\u9762\u79ef\u3002\u5e38\u4f4f4\u4eba\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u5b9e\u9645\u8fd0\u884c\u538b\u529b\u53ef\u63a7\u3002\n    <\/div>\n\n    <div class=\"lm-ok-line\">\n      <strong>\u65b9\u6848A\u4f18\u52bf\uff1a<\/strong>\u2460\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u6bd4\u666e\u901a\u6c1f\u673a\u8212\u9002\u5ea6\u5927\u5e45\u63d0\u5347\uff1b\u2461\u81ea\u5e26\u5730\u6696\u529f\u80fd\uff0c\u65e0\u9700\u72ec\u7acb\u9505\u7089\uff08\u4f46\u4e5f\u53ef\u9009\u914d\u72ec\u7acb\u9505\u7089\u505a\u5907\u4efd\uff09\uff1b\u2462\u65e5\u7acb\u539f\u5382\u6574\u5957\u7cfb\u7edf\uff0c\u7ef4\u4fdd\u65e0\u5fe7\uff1b\u24638.5\u6298\u4f18\u60e0\u529b\u5ea6\u5927\u3002\n    <\/div>\n  <\/div>\n\n  <p><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4ea7\u54c1\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a><\/p>\n\n  <div class=\"lm-pcard\" id=\"s3-b\">\n    <span class=\"lm-scheme-tag lm-tag-b\">\u65b9\u6848B \u00b7 \u8212\u4eab\u6c1f\u673a2\u62d67\uff088\u6298\uff09<\/span>\n    <h3>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u53cc\u5916\u673a\u591a\u8054\u673a\u7cfb\u7edf<\/h3>\n\n    <div class=\"lm-product-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-3.jpg\" alt=\"\u65e5\u7acbEX\u8212\u4eab\u7cfb\u5217\u5ba4\u5916\u673a\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n      <div class=\"lm-product-info\">\n        <h4>\u65e5\u7acbEX-\u8212\u4eab\u7cfb\u5217 \u2014 \u4e94\u7ef4\u4e00\u4f53\u68c0\u6d4b\u6e29\u5ea6\u6280\u672f<\/h4>\n        <p>\u901a\u8fc7\u4f20\u611f\u5668\u5b9e\u65f6\u611f\u77e5\u5ba4\u5185\u5916\u6e29\u5ea6\u53d8\u5316\uff0c\u81ea\u52a8\u8c03\u8282\u51fa\u98ce\u6e29\u5ea6\u4e0e\u98ce\u901f\uff0c\u6807\u51c6\u6c1f\u673a\u4e2d\u8212\u9002\u5ea6\u66f4\u4f18\uff1b\u53cc\u5916\u673a\u5206\u7cfb\u7edf\uff0c\u6545\u969c\u9694\u79bb\u6027\u597d\uff0c\u6027\u4ef7\u6bd4\u6700\u9ad8\u3002<\/p>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u67e5\u770b\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-pcard-summary\">\n      <span class=\"lm-badge lm-badge-info\">\u5916\u673a1\uff1aRAS-125HRNAQ (12.5kW)<\/span>\n      <span class=\"lm-badge lm-badge-info\">\u5916\u673a2\uff1aRAS-140HRNAQ (14.0kW)<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u8d85\u914d\u7387\uff1a103.2% \/ 108.6%<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u6298\u6263\uff1a8\u6298<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u7a7a\u8c03\u603b\u8ba1\uff1a52,160\u5143<\/span>\n    <\/div>\n\n    <h4>\u5916\u673a\u914d\u7f6e\uff082\u53f0\uff09<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u8bbe\u5907<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u5bb9\u91cf<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n          <th>8\u6298(\u5143)<\/th>\n          <th>\u5b89\u88c5\u8d39<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a1<\/td>\n          <td>RAS-125HRNAQ<\/td>\n          <td>12.5kW \u5355\u98ce\u6247<\/td>\n          <td>11,663<\/td>\n          <td>9,330<\/td>\n          <td>\u5df2\u542b<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5916\u673a2<\/td>\n          <td>RAS-140HRNAQ<\/td>\n          <td>14.0kW \u5355\u98ce\u6247<\/td>\n          <td>12,875<\/td>\n          <td>10,300<\/td>\n          <td>\u5df2\u542b<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h4>\u5185\u673a\u914d\u7f6e \u2014 125\u7cfb\u7edf\uff08\u62d64\u53f0\uff09<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u533a\u57df<\/th>\n          <th>\u9762\u79ef(\u33a1)<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u5bb9\u91cf(kW)<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n          <th>8\u6298(\u5143)<\/th>\n          <th>\u5b89\u88c5\u8d39(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e3b\u5367<\/td>\n          <td>28.42<\/td>\n          <td>RPIZ-50FSNAQD\/P<\/td>\n          <td>5.0<\/td>\n          <td>3,325<\/td>\n          <td>2,660<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6b21\u53671<\/td>\n          <td>17.45<\/td>\n          <td>RPIZ-32FSNAQD\/P<\/td>\n          <td>3.2<\/td>\n          <td>3,100<\/td>\n          <td>2,480<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5973\u513f\u623f\u95f4<\/td>\n          <td>15.11<\/td>\n          <td>RPIZ-25FSNAQD\/P<\/td>\n          <td>2.5<\/td>\n          <td>3,050<\/td>\n          <td>2,440<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u53a8\u623f<\/td>\n          <td>9.67<\/td>\n          <td>RCIS-22FSCN1QD<\/td>\n          <td>2.2<\/td>\n          <td>6,175<\/td>\n          <td>4,940<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n    <p><span class=\"lm-badge lm-badge-ok\">125\u5916\u673a\u8d85\u914d\u7387<\/span> \u5185\u673a5.0+3.2+2.5+2.2=12.9kW \u00f7 12.5kW = <strong>103.2%<\/strong>\uff08\u5b89\u5168\uff09<\/p>\n\n    <h4>\u63a7\u5236\u5668\u914d\u7f6e\uff086\u53f0WiFi\u7ebf\u63a7\u5668\uff09<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u8bbe\u5907<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n          <th>8\u6298(\u5143)<\/th>\n          <th>\u5907\u6ce8<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>WiFi\u7ebf\u63a7\u5668<\/td>\n          <td>PC-P1HVQA<\/td>\n          <td>6\u53f0<\/td>\n          <td>200\u00d76=1,200<\/td>\n          <td>960<\/td>\n          <td>\u4e3b\u5367\/\u6b21\u5367\/\u4e66\u623f\/\u5ba2\u9910\u5385\u00d72\/\u5973\u513f\u623f\u95f4\u54041\u53f0<\/td>\n        <\/tr>\n        <tr>\n          <td>\u53a8\u623f\u673a\u63a7\u5236\u5668<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>RCIS-22FSCN1QD\u53a8\u623f\u4e13\u7528\u673a\u81ea\u5e26\u63a7\u5236\u5668\uff0c\u4e0d\u53e6\u8ba1\u8d39<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td>\u63a7\u5236\u5668\u5408\u8ba1<\/td>\n          <td>\u2014<\/td>\n          <td>6\u53f0<\/td>\n          <td>1,200<\/td>\n          <td>960<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h4>\u5185\u673a\u914d\u7f6e \u2014 140\u7cfb\u7edf\uff08\u62d63\u53f0\uff09<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u533a\u57df<\/th>\n          <th>\u9762\u79ef(\u33a1)<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u5bb9\u91cf(kW)<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n          <th>8\u6298(\u5143)<\/th>\n          <th>\u5b89\u88c5\u8d39(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e66\u623f<\/td>\n          <td>11.62<\/td>\n          <td>RPIZ-18FSNAQD\/P<\/td>\n          <td>1.8<\/td>\n          <td>2,838<\/td>\n          <td>2,270<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba2\u9910\u5385<\/td>\n          <td>82.54<\/td>\n          <td>RPIZ-71FSNAQD\/P<\/td>\n          <td>7.1<\/td>\n          <td>3,513<\/td>\n          <td>2,810<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba2\u9910\u5385<\/td>\n          <td>82.54<\/td>\n          <td>RPIZ-63FSNAQD\/P<\/td>\n          <td>6.3<\/td>\n          <td>3,463<\/td>\n          <td>2,770<\/td>\n          <td>1,600<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n    <p><span class=\"lm-badge lm-badge-ok\">140\u5916\u673a\u8d85\u914d\u7387<\/span> \u5185\u673a1.8+7.1+6.3=15.2kW \u00f7 14.0kW = <strong>108.6%<\/strong>\uff08\u5b89\u5168\uff09<\/p>\n\n    <h4>\u8d39\u7528\u6c47\u603b<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u660e\u7ec6<\/th>\n          <th>\u91d1\u989d(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u6298\u540e\u8bbe\u5907\u5408\u8ba1<\/td>\n          <td>2\u53f0\u5916\u673a19,630 + 7\u53f0\u5185\u673a20,370 + \u63a7\u5236\u5668960<\/td>\n          <td>40,960<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5b89\u88c5\u8d39\u5408\u8ba1<\/td>\n          <td>7\u53f0 \u00d7 1,600<\/td>\n          <td>11,200<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td>\u65b9\u6848B\u7a7a\u8c03\u603b\u8ba1<\/td>\n          <td>\u8bbe\u5907 + \u5b89\u88c5<\/td>\n          <td>52,160 \u2248 5.22\u4e07<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"lm-ok-line\">\n      <strong>\u65b9\u6848B\u4f18\u52bf\uff1a<\/strong>\u2460\u8d85\u914d\u7387\u5b89\u5168\uff08103.2%\/108.6%\uff09\uff0c\u8fd0\u884c\u7a33\u5b9a\uff1b\u2461\u53cc\u5916\u673a\u5206\u7cfb\u7edf\uff0c\u6545\u969c\u9694\u79bb\u6027\u597d\uff1b\u24628\u6298\u4f18\u60e0+\u8212\u4eab\u7cfb\u5217\u672c\u8eab\u5b9a\u4ef7\u4f4e\uff0c\u6027\u4ef7\u6bd4\u6700\u9ad8\uff1b\u2463\u9700\u914d\u72ec\u7acb\u5730\u6696\uff08\u65b9\u68481\/2\/3\u53ef\u9009\uff09\u3002\n    <\/div>\n    <div class=\"lm-warn-line\">\n      <strong>\u65b9\u6848B\u52a3\u52bf\uff1a<\/strong>\u6807\u51c6\u6c1f\u673a\u51fa\u98ce7-10\u2103\uff0c\u8212\u9002\u5ea6\u4e0d\u53ca\u6c34\u673a\u548c\u4e09\u7ba1\u5236\u7cfb\u7edf\uff1b\u65e0\u5730\u6696\u529f\u80fd\uff0c\u9700\u989d\u5916\u914d\u7f6e\u72ec\u7acb\u5730\u6696\u7cfb\u7edf\u3002\u4f46\u65e5\u7acb\u4e94\u7ef4\u4e00\u4f53\u68c0\u6d4b\u6e29\u5ea6\u6280\u672f\u4f7f\u8212\u9002\u5ea6\u4f18\u4e8e\u5176\u4ed6\u54c1\u724c\u6c1f\u673a\u3002\n    <\/div>\n  <\/div>\n\n  <p><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4ea7\u54c1\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a><\/p>\n\n  <div class=\"lm-pcard\" id=\"s3-c\">\n    <span class=\"lm-scheme-tag lm-tag-f\">\u65b9\u6848C \u00b7 \u6c34\u5885\u9002FX\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\uff08\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\uff09<\/span>\n    <h3>\u65e5\u7acb\u6c34\u5885\u9002FX \u00b7 \u5168\u6c34\u7cfb\u7edf\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b<\/h3>\n\n    <div class=\"lm-product-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6c34\u5885\u9002FX02.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002FX\u5ba4\u5916\u673a\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n      <div class=\"lm-product-info\">\n        <h4>\u65e5\u7acb\u6c34\u5885\u9002FX \u2014 \u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\/\u667a\u5885\u5168\u611f\u4e94\u6052\u7cfb\u7edf<\/h4>\n        <p>\u4ee5\u6c34\u6c1f\u6362\u70ed\u5b9e\u73b0\u51fa\u98ce15-17\u2103\u67d4\u548c\u9001\u98ce\uff0c\u5f7b\u5e95\u89e3\u51b3\"\u8d8a\u5439\u8d8a\u51b7\"\u75db\u70b9\uff1b\u70ed\u6cf5\u4e3b\u673a\u76f4\u63a5\u5e26\u5730\u6696\uff0c\u65e0\u9505\u7089\u3001\u65e0\u71c3\u6c14\uff0c\u9002\u5408\u6709\u5c0f\u5b69\u3001\u540c\u5f00\u7387\u9ad8\u7684\u5bb6\u5ead\u3002<\/p>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\">\u67e5\u770b\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-pcard-summary\">\n      <span class=\"lm-badge lm-badge-info\">\u5916\u673a\uff1aRAS-180FPUEN2Q\/M (18kW)<\/span>\n      <span class=\"lm-badge lm-badge-info\">\u5185\u673a\uff1a\u96f6\u8d8aDBT\u7cfb\u5217\u6c34\u98ce\u76d8<\/span>\n      <span class=\"lm-badge lm-badge-ok\">\u70ed\u6cf5\u5e26\u5730\u6696\uff08\u65e0\u9700\u9505\u7089\uff09<\/span>\n      <span class=\"lm-badge lm-badge-warn\">\u90e8\u5206\u4ef7\u683c\u5f85\u8be2\u4ef7<\/span>\n    <\/div>\n\n    <h4>\u5916\u673a\u914d\u7f6e<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u8bbe\u5907<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u5bb9\u91cf<\/th>\n          <th>\u96f6\u552e\u4ef7(\u5143)<\/th>\n          <th>\u4e3b\u673a\u5b89\u88c5(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a<\/td>\n          <td>RAS-180FPUEN2Q\/M<\/td>\n          <td>18.0kW \u53cc\u8f6c\u5b50\u53cc\u98ce\u6247<\/td>\n          <td>30,110<\/td>\n          <td>3,600<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h4>\u5185\u673a\u914d\u7f6e\uff08\u96f6\u8d8aDBT\u7cfb\u5217\u6c34\u98ce\u76d8\uff0c6\u53f0\uff09<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u533a\u57df<\/th>\n          <th>\u9762\u79ef(\u33a1)<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u96f6\u552e\u4ef7(\u5143)<\/th>\n          <th>\u9009\u6750\u8d39(\u5143)<\/th>\n          <th>\u4eba\u5de5\u8d39(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e3b\u5367<\/td>\n          <td>28.42<\/td>\n          <td>RFP-85WAR\/DBT12Y03\/P<\/td>\n          <td>3,086<\/td>\n          <td>1,800<\/td>\n          <td>2,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6b21\u53671<\/td>\n          <td>17.45<\/td>\n          <td>RFP-51WAR\/DBT12Y03\/P<\/td>\n          <td>2,752<\/td>\n          <td>1,800<\/td>\n          <td>2,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5973\u513f\u623f\u95f4<\/td>\n          <td>15.11<\/td>\n          <td>RFP-51WAR\/DBT12Y03\/P<\/td>\n          <td>2,752<\/td>\n          <td>1,800<\/td>\n          <td>2,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e66\u623f<\/td>\n          <td>11.62<\/td>\n          <td>RFP-34WAR\/DBT12Y03\/P<\/td>\n          <td>2,625<\/td>\n          <td>1,800<\/td>\n          <td>2,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba2\u9910\u5385<\/td>\n          <td>82.54<\/td>\n          <td>RFP-156WAR\/DBT12Y03\/P<\/td>\n          <td>4,930<\/td>\n          <td>1,800<\/td>\n          <td>2,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba2\u9910\u5385<\/td>\n          <td>82.54<\/td>\n          <td>RFP-136WAR\/DBT12Y03\/P<\/td>\n          <td>4,700<\/td>\n          <td>1,800<\/td>\n          <td>2,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u53a8\u623f<\/td>\n          <td>9.67<\/td>\n          <td>\u2014\uff08\u4e0d\u88c5\uff09<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h4>\u8d39\u7528\u6c47\u603b<\/h4>\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u660e\u7ec6<\/th>\n          <th>\u91d1\u989d(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u8bbe\u5907\u5408\u8ba1<\/td>\n          <td>\u5916\u673a30,110 + 6\u53f0\u5185\u673a20,845<\/td>\n          <td>50,955<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5b89\u88c5\/\u9009\u6750\/\u4eba\u5de5\u5408\u8ba1<\/td>\n          <td>\u4e3b\u673a\u5b89\u88c53,600 + 6\u53f0\u9009\u675010,800 + 6\u53f0\u4eba\u5de512,000<\/td>\n          <td>26,400<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td>\u65b9\u6848C\u7a7a\u8c03\u603b\u8ba1<\/td>\n          <td>\u8bbe\u5907 + \u5b89\u88c5\u9009\u6750\u4eba\u5de5<\/td>\n          <td>77,355<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"lm-ok-line\">\n      <strong>RFP-156WAR\u5df2\u62a5\u4ef7\uff1a<\/strong>RFP-156WAR\/DBT12Y03\/P \u96f6\u552e\u4ef7 <strong>4,930\u5143<\/strong>\u3002\u65b9\u6848C\u8bbe\u5907\u5408\u8ba150,955\u5143\uff0c\u7a7a\u8c03\u603b\u8ba177,355\u5143\uff08\u7ea67.74\u4e07\uff09\uff0c\u4e0d\u542b\u5730\u6696\u7ba1\u8def\u3002\n    <\/div>\n\n    <div class=\"lm-ok-line\">\n      <strong>\u65b9\u6848C\u4f18\u52bf\uff1a<\/strong>\u2460\u51fa\u98ce15-17\u2103\u67d4\u548c\uff0c\u6700\u76f4\u63a5\u89e3\u51b3\"\u8d8a\u5439\u8d8a\u51b7\"\u75db\u70b9\uff1b\u2461\u6c34\u673a\u70ed\u6cf5\u76f4\u63a5\u5e26\u5730\u6696\uff0c\u65e0\u9700\u72ec\u7acb\u9505\u7089\u70e7\u6c14\uff0c\u5730\u6696\u8fd0\u884c\u8d39\u66f4\u4f4e\uff1b\u2462\u6c34\u98ce\u76d8\u8fd0\u884c\u9759\u97f3\u597d\uff1b\u2463\u5168\u6c34\u7cfb\u7edf\u8212\u9002\u5ea6\u6700\u9ad8\uff0c\u5c24\u5176\u9002\u5408\u6709\u5c0f\u5b69\u5bb6\u5ead\u3002\n    <\/div>\n    <div class=\"lm-warn-line\">\n      <strong>\u65b9\u6848C\u52a3\u52bf\uff1a<\/strong>\u2460\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\uff0c\u603b\u4ef7\u504f\u9ad8\uff1b\u2461\u53a8\u623f\u4e0d\u88c5\u7a7a\u8c03\uff08\u6c34\u98ce\u76d8\u4e0d\u9002\u5408\u53a8\u623f\u6cb9\u6c61\u73af\u5883\uff09\uff1b\u2462\u6c34\u7cfb\u7edf\u7ef4\u62a4\u6bd4\u6c1f\u673a\u7565\u590d\u6742\uff08\u9700\u5b9a\u671f\u68c0\u67e5\u6c34\u8d28\u3001\u6c34\u529b\u5e73\u8861\uff09\u3002\n    <\/div>\n  <\/div>\n\n  <p><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\">\u65e5\u7acb\u6c34\u5885\u9002\/\u4e24\u8054\u4f9b\u4ea7\u54c1\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a><\/p>\n\n  <h3 id=\"s3-floor\">\u5730\u6696\u4e09\u65b9\u6848\u5bf9\u6bd4\uff08\u72ec\u7acb\u9505\u7089\u5730\u6696\uff0c\u4ec5\u4f9b\u65b9\u6848B\u642d\u914d\uff09<\/h3>\n  <p><strong>\u65b9\u6848A\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/strong>\u81ea\u5e26\u6c34\u6a21\u5757\u53ef\u5e26\u5730\u6696\uff0c\u65e0\u9700\u72ec\u7acb\u9505\u7089\uff0c\u53ea\u9700\u7ba1\u8def\u8d39\u7528\uff08\u8282\u80fd\u578b28,882\u5143\uff09\u3002<strong>\u65b9\u6848C\uff08\u5929\u6c34\u5730\u6c34\uff09<\/strong>\u6c34\u673a\u70ed\u6cf5\u76f4\u63a5\u5e26\u5730\u6696\uff0c\u4e5f\u65e0\u9700\u72ec\u7acb\u9505\u7089\uff0c\u540c\u6837\u53ea\u9700\u7ba1\u8def\u8d39\u7528\u3002\u4ee5\u4e0b\u5730\u6696\u4e09\u65b9\u6848\uff08\u83f2\u65af\u66fc\/\u535a\u4e16\/\u66fc\u745e\u5fb7\uff09\u4ec5\u4f9b<strong>\u65b9\u6848B\uff08\u8212\u4eab\u6c1f\u673a\uff09<\/strong>\u642d\u914d\u9009\u62e9\u3002\u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\u67e5\u770b\u53c2\u6570\u4e0e\u4ef7\u683c\u3002\u4e86\u89e3\u66f4\u591a\u5730\u6696\u77e5\u8bc6\u8bf7\u8bbf\u95ee<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u5730\u6696\u7cfb\u7edf\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a>\u3002<\/p>\n\n  <div class=\"lm-floor-grid\">\n    <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\">\n      <div class=\"lm-flip-inner\">\n        <div class=\"lm-floor-front\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u83f2\u65af\u66fcB1JG\u56fd\u4ea7\u51b7\u51dd\u7089.jpg\" alt=\"\u83f2\u65af\u66fcB1JG\u56fd\u4ea7\u51b7\u51dd\u7089\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n          <div class=\"lm-floor-front-body\">\n            <h4>\u5730\u66961 \u00b7 \u83f2\u65af\u66fcB1JG<\/h4>\n            <div class=\"model\">B1JG 25kW\u51b7\u51dd \u00b7 \u4e24\u7528\u7089<\/div>\n            <div class=\"price\">\u00a513,597<\/div>\n            <div class=\"price-note\">\u9505\u7089\u9762\u4ef7\uff08\u5b89\u88c5\/\u7ba1\u8def\u53e6\u8ba1\uff09<\/div>\n            <a class=\"detail-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\">\u67e5\u770b\u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a>\n            <div class=\"hint\">\u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u53c2\u6570\u4e0e\u603b\u4ef7<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"lm-floor-back\">\n          <h4>\u83f2\u65af\u66fcB1JG \u53c2\u6570\u4ef7\u683c<\/h4>\n          <table>\n            <tbody><tr><th>\u9879\u76ee<\/th><th>\u53c2\u6570\/\u4ef7\u683c<\/th><\/tr>\n            <tr><td>\u9505\u7089\u578b\u53f7<\/td><td>B1JG 25kW\u51b7\u51dd<\/td><\/tr>\n            <tr><td>\u9505\u7089\u9762\u4ef7<\/td><td>13,597\u5143<\/td><\/tr>\n            <tr><td>\u6298\u6263<\/td><td><span class=\"lm-pill lm-pill-gray\">\u9762\u4ef7\u4e0d\u6253\u6298<\/span><\/td><\/tr>\n            <tr><td>\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>600\u5143<\/td><\/tr>\n            <tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u4e24\u7528\u7089\uff08\u91c7\u6696+\u70ed\u6c34\uff09<\/td><\/tr>\n            <tr><td>\u7ba1\u8def-\u901a\u914d\u578b<\/td><td>170.9\u33a1\u00d7119=20,337\u5143<\/td><\/tr>\n            <tr><td>\u7ba1\u8def-\u8282\u80fd\u578b<\/td><td>170.9\u33a1\u00d7169=28,882\u5143<\/td><\/tr>\n            <tr><td>\u603b\u8ba1\uff08\u901a\u914d\u578b\uff09<\/td><td><strong>34,534\u5143 \u2248 3.45\u4e07<\/strong><\/td><\/tr>\n            <tr><td>\u603b\u8ba1\uff08\u8282\u80fd\u578b\uff09<\/td><td><strong>43,079\u5143 \u2248 4.31\u4e07<\/strong><\/td><\/tr>\n          <\/tbody><\/table>\n          <p class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u8fd4\u56de\u6b63\u9762<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\">\n      <div class=\"lm-flip-inner\">\n        <div class=\"lm-floor-front\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u535a\u4e16\u58c1\u6302\u7089-G6100W-1.jpg\" alt=\"\u535a\u4e16\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n          <div class=\"lm-floor-front-body\">\n            <h4>\u5730\u66962 \u00b7 \u535a\u4e16Condens3260w<\/h4>\n            <div class=\"model\">Condens3260w 25kW\u51b7\u51dd \u00b7 \u4e24\u7528\u7089<\/div>\n            <div class=\"price\">\u00a59,575<\/div>\n            <div class=\"price-note\">\u9505\u7089\u9762\u4ef7\uff08\u5b89\u88c5\/\u7ba1\u8def\u53e6\u8ba1\uff09<\/div>\n            <a class=\"detail-link\" href=\"https:\/\/longmai-nt.com\/?page_id=835\" target=\"_blank\">\u67e5\u770b\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a>\n            <div class=\"hint\">\u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u53c2\u6570\u4e0e\u603b\u4ef7<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"lm-floor-back\">\n          <h4>\u535a\u4e16Condens3260w \u53c2\u6570\u4ef7\u683c<\/h4>\n          <table>\n            <tbody><tr><th>\u9879\u76ee<\/th><th>\u53c2\u6570\/\u4ef7\u683c<\/th><\/tr>\n            <tr><td>\u9505\u7089\u578b\u53f7<\/td><td>Condens3260w 25kW\u51b7\u51dd<\/td><\/tr>\n            <tr><td>\u9505\u7089\u9762\u4ef7<\/td><td>9,575\u5143<\/td><\/tr>\n            <tr><td>\u6298\u6263<\/td><td><span class=\"lm-pill lm-pill-gray\">\u9762\u4ef7\u4e0d\u6253\u6298<\/span><\/td><\/tr>\n            <tr><td>\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>600\u5143<\/td><\/tr>\n            <tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u4e24\u7528\u7089\uff08\u91c7\u6696+\u70ed\u6c34\uff09<\/td><\/tr>\n            <tr><td>\u7ba1\u8def-\u901a\u914d\u578b<\/td><td>170.9\u33a1\u00d7119=20,337\u5143<\/td><\/tr>\n            <tr><td>\u7ba1\u8def-\u8282\u80fd\u578b<\/td><td>170.9\u33a1\u00d7169=28,882\u5143<\/td><\/tr>\n            <tr><td>\u603b\u8ba1\uff08\u901a\u914d\u578b\uff09<\/td><td><strong>30,512\u5143 \u2248 3.05\u4e07<\/strong><\/td><\/tr>\n            <tr><td>\u603b\u8ba1\uff08\u8282\u80fd\u578b\uff09<\/td><td><strong>39,057\u5143 \u2248 3.91\u4e07<\/strong><\/td><\/tr>\n          <\/tbody><\/table>\n          <p class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u8fd4\u56de\u6b63\u9762<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\">\n      <div class=\"lm-flip-inner\">\n        <div class=\"lm-floor-front\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u58c1\u6302\u7089.jpg\" alt=\"\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n          <div class=\"lm-floor-front-body\">\n            <h4>\u5730\u66963 \u00b7 \u66fc\u745e\u5fb7\u5206\u79bb\u5f0f<\/h4>\n            <div class=\"model\">24kW\u5206\u6bb5\u71c3\u70e7 \u00b7 \u5206\u79bb\u5f0f\u7cfb\u7edf<\/div>\n            <div class=\"price\">\u00a55,599<\/div>\n            <div class=\"price-note\">\u9505\u7089\u9762\u4ef7\uff08\u70ed\u6c34\u5668\u5f85\u8be2\u4ef7\uff09<\/div>\n            <a class=\"detail-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\">\u67e5\u770b\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a>\n            <div class=\"hint\">\u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u53c2\u6570\u4e0e\u603b\u4ef7<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"lm-floor-back\">\n          <h4>\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f \u53c2\u6570\u4ef7\u683c<\/h4>\n          <table>\n            <tbody><tr><th>\u9879\u76ee<\/th><th>\u53c2\u6570\/\u4ef7\u683c<\/th><\/tr>\n            <tr><td>\u9505\u7089\u578b\u53f7<\/td><td>24kW\u5206\u6bb5\u71c3\u70e7<\/td><\/tr>\n            <tr><td>\u9505\u7089\u9762\u4ef7<\/td><td>5,599\u5143<\/td><\/tr>\n            <tr><td>\u6298\u6263<\/td><td><span class=\"lm-pill lm-pill-gray\">\u9762\u4ef7\u4e0d\u6253\u6298<\/span><\/td><\/tr>\n            <tr><td>\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>600\u5143<\/td><\/tr>\n            <tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td><span class=\"lm-pill lm-pill-green\">\u5206\u79bb\u5f0f<\/span> \u9505\u7089\u5e26\u5730\u6696+\u53a8\u623f\u70ed\u6c34\uff0c16L\u70ed\u6c34\u5668\u7ba1\u536b\u751f\u95f4\u70ed\u6c34<\/td><\/tr>\n            <tr><td>\u7ba1\u8def-\u8282\u80fd\u578b<\/td><td>170.9\u33a1\u00d7169=28,882\u5143<\/td><\/tr>\n            <tr><td>\u9644\u52a0\u8bbe\u5907<\/td><td>16L\u96f6\u51b7\u6c34\u70ed\u6c34\u5668 <span class=\"lm-pill lm-pill-red\">\u5f85\u8be2\u4ef7<\/span><\/td><\/tr>\n            <tr><td>\u603b\u8ba1\uff08\u8282\u80fd\u578b\uff09<\/td><td><strong>35,081\u5143 + \u70ed\u6c34\u5668 \u2248 3.81\u4e07+\u70ed\u6c34\u5668<\/strong><\/td><\/tr>\n          <\/tbody><\/table>\n          <p class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u8fd4\u56de\u6b63\u9762<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-geo-card\">\n    <h4>\u5730\u66963 \u00b7 \u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\u6838\u5fc3\u4f18\u52bf<\/h4>\n    <p>\u4f20\u7edf\u4e24\u7528\u7089\uff08\u83f2\u65af\u66fc\/\u535a\u4e16\uff09\u4e00\u53f0\u673a\u5668\u517c\u987e\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\uff0c\u51ac\u5929\u6d17\u6fa1\u65f6\u5730\u6696\u6e29\u5ea6\u53ef\u80fd\u6ce2\u52a8\u3002<\/p>\n    <p><strong>\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\uff1a<\/strong>24kW\u9505\u7089\u4e13\u804c\u5e26\u5730\u6696+\u53a8\u623f\u70ed\u6c34\uff0c16L\u70ed\u6c34\u5668\u4e13\u804c\u7ba1\u536b\u751f\u95f4\u70ed\u6c34\uff0c<strong>\u91c7\u6696\u70ed\u6c34\u5b8c\u5168\u5206\u79bb\u4e92\u4e0d\u5e72\u6270<\/strong>\u3002<\/p>\n    <ul>\n      <li>\u6d17\u6fa1\u65f6\u5730\u6696\u4e0d\u53d7\u5f71\u54cd\uff0c\u6e29\u5ea6\u7a33\u5b9a<\/li>\n      <li>\u9505\u7089\u529f\u7387\u5145\u8db3\uff0824kW\uff09\uff0c\u91c7\u6696\u6548\u679c\u597d<\/li>\n      <li>16L\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\uff0c\u79d2\u51fa\u70ed\u6c34\uff0c\u536b\u751f\u95f4\u4f53\u9a8c\u597d<\/li>\n      <li>\u9505\u7089\u9762\u4ef7\u4ec55,599\u5143\uff0c\u6574\u4f53\u6027\u4ef7\u6bd4\u9ad8<\/li>\n      <li>16L\u70ed\u6c34\u5668\u4ef7\u683c<span class=\"lm-pill lm-pill-red\">\u5f85\u8be2\u4ef7<\/span>\uff08\u9884\u8ba1\u7ea63,000-4,000\u5143\uff09<\/li>\n    <\/ul>\n    <p>\u4e86\u89e3\u66f4\u591a\u70ed\u6c34\u7cfb\u7edf\u65b9\u6848\u8bf7\u8bbf\u95ee<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1879\" target=\"_blank\">\u70ed\u6c34\u7cfb\u7edf\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a>\u3002<\/p>\n  <\/div>\n\n  <div class=\"lm-warn-line\">\n    <strong>\u7ba1\u8def\u9009\u62e9\u5efa\u8bae\uff1a<\/strong>170.9\u33a1\u5730\u6696\u9762\u79ef\uff0c\u5efa\u8bae\u9009<strong>\u8282\u80fd\u578b\u7ba1\u8def<\/strong>\uff08169\u5143\/\u33a1\uff09\u3002\u8282\u80fd\u578b\u91c7\u7528\u66f4\u4f18\u7684\u7ba1\u95f4\u8ddd\u548c\u4fdd\u6e29\u5c42\uff0c\u70ed\u635f\u5931\u66f4\u5c0f\uff0c\u957f\u671f\u8fd0\u884c\u66f4\u7701\u6c14\u3002\u901a\u914d\u578b\u521d\u671f\u7701\u94b1\u4f46\u957f\u671f\u8fd0\u884c\u8d39\u7528\u66f4\u9ad8\u3002<strong>\u4e3b\u7ba1\u5fc5\u987b\u752840\u7ba1<\/strong>\u2014\u201425\u7ba1\u6d41\u91cf\u4e0d\u591f\uff0c\u51b7\u51dd\u7089\u53d8\u9ad8\u6e29\u70e7\uff0c\u8282\u80fd\u4f18\u52bf\u5168\u65e0\u3002\n  <\/div>\n\n  <h3 id=\"s3-freshair\">\u65b0\u98ce\u7cfb\u7edf\u63a8\u8350\uff08\u4e91\u51c0250 vs \u5929\u51c0250\uff09<\/h3>\n  <p>260\u33a1\u5927\u5e73\u5c42\u5efa\u8bae\u914d\u7f6e\u65b0\u98ce\u7cfb\u7edf\uff0c\u6539\u5584\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u3002\u5e38\u4f4f4\u4eba\uff0c\u5efa\u8bae\u81f3\u5c11250\u98ce\u91cf\uff0c\u5efa\u8bae250-350\u98ce\u91cf\u3002\u70b9\u51fb\u5361\u7247\u53ef\u7ffb\u8f6c\u67e5\u770b\u8be6\u7ec6\u53c2\u6570\u5bf9\u6bd4\u3002<\/p>\n\n  <div class=\"lm-freshair-grid\">\n    <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\">\n      <div class=\"lm-flip-inner\">\n        <div class=\"lm-flip-front\">\n          <img decoding=\"async\" class=\"lm-freshair-front-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce04-15.jpg\" alt=\"\u65e5\u7acb\u4e91\u51c0\u2161\u65b0\u98ce\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n          <div class=\"lm-freshair-front-body\">\n            <h4>\u65e5\u7acb\u4e91\u51c0\u2161<\/h4>\n            <div class=\"model\">KPI-2521Q3A\/F \u00b7 250\u98ce\u91cf<\/div>\n            <div class=\"price\">\u00a55,500<\/div>\n            <a class=\"detail-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u67e5\u770b\u65e5\u7acb\u65b0\u98ce\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n            <div class=\"hint\">\u5168\u70ed\u4ea4\u6362\u57fa\u7840\u578b \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u53c2\u6570<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"lm-flip-back lm-freshair-back\">\n          <h4>\u4e91\u51c0\u2161 \u53c2\u6570<\/h4>\n          <table>\n            <tbody><tr><th>\u9879\u76ee<\/th><th>\u53c2\u6570<\/th><\/tr>\n            <tr><td>\u4ea7\u54c1\u5b9a\u4f4d<\/td><td>\u5168\u70ed\u4ea4\u6362\u57fa\u7840\u578b<\/td><\/tr>\n            <tr><td>\u70ed\u56de\u6536\u6548\u7387<\/td><td>80%<\/td><\/tr>\n            <tr><td>\u667a\u80fd\u529f\u80fd<\/td><td>\u57fa\u7840\u70ed\u56de\u6536<\/td><\/tr>\n            <tr><td>\u51c0\u5316\u7b49\u7ea7<\/td><td>\u6807\u51c6\u8fc7\u6ee4<\/td><\/tr>\n            <tr><td>\u9762\u4ef7<\/td><td>5,500\u5143<\/td><\/tr>\n            <tr><td>\u5b89\u88c5\u8d39<\/td><td>6,000\u5143<\/td><\/tr>\n            <tr><td>\u5408\u8ba1<\/td><td><strong>11,500\u5143<\/strong><\/td><\/tr>\n          <\/tbody><\/table>\n          <p class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u8fd4\u56de\u6b63\u9762<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\">\n      <div class=\"lm-flip-inner\">\n        <div class=\"lm-flip-front\">\n          <img decoding=\"async\" class=\"lm-freshair-front-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce04-19.jpg\" alt=\"\u65e5\u7acb\u5929\u51c0Q5\u65b0\u98ce\u4ea7\u54c1\u56fe\" loading=\"lazy\">\n          <div class=\"lm-freshair-front-body\">\n            <h4>\u65e5\u7acb\u5929\u51c0Q5<\/h4>\n            <div class=\"model\">KPI-2521Q5\/F \u00b7 250\u98ce\u91cf<\/div>\n            <div class=\"price\">\u00a58,600<\/div>\n            <a class=\"detail-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u67e5\u770b\u65e5\u7acb\u65b0\u98ce\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n            <div class=\"hint\">\u5168\u70ed\u4ea4\u6362\u667a\u80fd\u578b \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u53c2\u6570<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"lm-flip-back lm-freshair-back\">\n          <h4>\u5929\u51c0Q5 \u53c2\u6570<\/h4>\n          <table>\n            <tbody><tr><th>\u9879\u76ee<\/th><th>\u53c2\u6570<\/th><\/tr>\n            <tr><td>\u4ea7\u54c1\u5b9a\u4f4d<\/td><td>\u5168\u70ed\u4ea4\u6362\u667a\u80fd\u578b<\/td><\/tr>\n            <tr><td>\u70ed\u56de\u6536\u6548\u7387<\/td><td>80%+\uff08\u542b\u7a7a\u6c14\u53ef\u89c6\u5316\uff09<\/td><\/tr>\n            <tr><td>\u667a\u80fd\u529f\u80fd<\/td><td>\u7a7a\u6c14\u53ef\u89c6\u5316+WiFi+\u56db\u7ea7\u51c0\u5316<\/td><\/tr>\n            <tr><td>\u51c0\u5316\u7b49\u7ea7<\/td><td>\u521d\u6548+\u4e2d\u6548+HEPA+\u6d3b\u6027\u70ad<\/td><\/tr>\n            <tr><td>\u9762\u4ef7<\/td><td>8,600\u5143<\/td><\/tr>\n            <tr><td>\u5b89\u88c5\u8d39<\/td><td>6,000\u5143<\/td><\/tr>\n            <tr><td>\u5408\u8ba1<\/td><td><strong>14,600\u5143<\/strong><\/td><\/tr>\n          <\/tbody><\/table>\n          <p class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u8fd4\u56de\u6b63\u9762<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-geo-card\">\n    <h4>\u6838\u5fc3\u533a\u522b\u4e0e\u9009\u8d2d\u5efa\u8bae<\/h4>\n    <ul>\n      <li><strong>\u4e91\u51c0\u2161\uff08KPI-2521Q3A\/F\uff09<\/strong>\u662f\u5168\u70ed\u4ea4\u6362\u57fa\u7840\u578b\uff0c\u70ed\u56de\u6536\u6548\u738780%\uff0c\u6ee1\u8db3\u57fa\u7840\u65b0\u98ce\u6362\u6c14\u9700\u6c42\uff0c\u6027\u4ef7\u6bd4\u9ad8\u3002<\/li>\n      <li><strong>\u5929\u51c0Q5\uff08KPI-2521Q5\/F\uff09<\/strong>\u662f\u5168\u70ed\u4ea4\u6362\u667a\u80fd\u578b\uff0c\u70ed\u56de\u6536\u6548\u738780%+\uff0c\u989d\u5916\u5177\u5907\u7a7a\u6c14\u53ef\u89c6\u5316\uff08\u5b9e\u65f6PM2.5\/CO\u2082\u663e\u793a\uff09\u3001WiFi\u8fdc\u7a0b\u63a7\u5236\u3001\u56db\u7ea7\u51c0\u5316\uff08\u521d\u6548+\u4e2d\u6548+\u9ad8\u6548HEPA+\u6d3b\u6027\u70ad\uff09\u7b49\u667a\u80fd\u529f\u80fd\u3002<\/li>\n    <\/ul>\n    <p>260\u33a1\u5927\u5e73\u5c42\u5e38\u4f4f4\u4eba\uff0c\u5efa\u8bae\u81f3\u5c11250\u98ce\u91cf\u3002\u5982\u9884\u7b97\u5145\u8db3\uff0c\u63a8\u8350\u5929\u51c0Q5\u667a\u80fd\u578b\uff0c\u7a7a\u6c14\u8d28\u91cf\u53ef\u89c6\u5316\u5bf9\u6709\u5c0f\u5b69\u5bb6\u5ead\u66f4\u6709\u4ef7\u503c\u3002\u9762\u4ef7\u53ef\u6309\u6d3b\u52a8\u6298\u6263\u4f18\u60e0\u3002<\/p>\n    <p>\u4e86\u89e3\u66f4\u591a\u65e5\u7acb\u65b0\u98ce\u4ea7\u54c1\u53c2\u6570\u8bf7\u8bbf\u95ee<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u65e5\u7acb\u65b0\u98ce\u4ea7\u54c1\u53c2\u6570 \u2014 \u9f99\u8109\u6696\u901a<\/a>\u3002<\/p>\n  <\/div>\n\n  <h3 id=\"s3-six\">\u4e5d\u7ef4\u5ea6\u7efc\u5408\u5bf9\u6bd4<\/h3>\n  <p>\u5c06\u8212\u9002\u5ea6\u3001\u6e7f\u5ea6\u63a7\u5236\u3001\u80fd\u6548\u3001\u521d\u59cb\u6295\u8d44\u3001\u7ef4\u62a4\u3001\u53ef\u9760\u6027\u3001\u5b89\u88c5\u590d\u6742\u5ea6\u3001\u81ea\u6e05\u6d01\u3001\u9ad8\u6e29\u6740\u83cc\u4e5d\u4e2a\u7ef4\u5ea6\u91cf\u5316\u8bc4\u5206\uff0c\u7528\u96f7\u8fbe\u56fe\u76f4\u89c2\u5c55\u793a\u4e09\u65b9\u6848\u5404\u81ea\u4f18\u52bf\u3002<\/p>\n\n  <div class=\"lm-chart-wrap\">\n    <h4 style=\"text-align:center;\">\u4e09\u65b9\u6848\u4e5d\u7ef4\u5ea6\u80fd\u529b\u96f7\u8fbe\u56fe\uff085\u5206\u5236\uff09<\/h4>\n    <div class=\"lm-radar-canvas\">\n      <canvas id=\"nineDimChart\"><\/canvas>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-geo-card\">\n    <h4>\u96f7\u8fbe\u56fe\u89e3\u8bfb<\/h4>\n    <ul>\n      <li><strong>\u65b9\u6848A\uff08\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\uff09\uff1a<\/strong>\u8212\u9002\u5ea6\u3001\u6e7f\u5ea6\u63a7\u5236\u3001\u53ef\u9760\u6027\u3001\u81ea\u6e05\u6d01\/\u9ad8\u6e29\u6740\u83cc\u5168\u9762\u9ad8\u5206\uff0c\u53ea\u5728\u5b89\u88c5\u590d\u6742\u5ea6\u4e0a\u7565\u6263\uff1b\u662f<strong>\u7efc\u5408\u80fd\u529b\u6700\u5f3a<\/strong>\u7684\u9009\u62e9\u3002<\/li>\n      <li><strong>\u65b9\u6848B\uff08\u8212\u4eab\u6c1f\u673a\uff09\uff1a<\/strong>\u521d\u59cb\u6295\u8d44\u548c\u7ef4\u62a4\u4fbf\u5229\u6027\u6700\u4f18\uff0c\u4f46\u6e7f\u5ea6\u63a7\u5236\u3001\u80fd\u6548\u3001\u8212\u9002\u5ea6\u5f31\u4e8eA\/C\uff1b\u662f<strong>\u6027\u4ef7\u6bd4\u6700\u9ad8<\/strong>\u7684\u9009\u62e9\u3002<\/li>\n      <li><strong>\u65b9\u6848C\uff08\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff09\uff1a<\/strong>\u8212\u9002\u5ea6\u6ee1\u5206\u3001\u8fd0\u884c\u8d39\u4f4e\uff0c\u4f46\u7ef4\u62a4\u4fbf\u5229\u6027\u3001\u5b89\u88c5\u590d\u6742\u5ea6\u3001\u81ea\u6e05\u6d01\/\u9ad8\u6e29\u6740\u83cc\u5f97\u5206\u8f83\u4f4e\uff1b\u662f<strong>\u4f53\u611f\u6700\u67d4\u548c<\/strong>\u7684\u9009\u62e9\u3002<\/li>\n    <\/ul>\n  <\/div>\n\n  <h3 id=\"s3-summary\">\u62a5\u4ef7\u660e\u7ec6\u6c47\u603b\u8868<\/h3>\n  <table>\n    <thead>\n      <tr>\n        <th>\u7ec4\u5408\u65b9\u6848<\/th>\n        <th>\u7a7a\u8c03<\/th>\n        <th>\u5730\u6696<\/th>\n        <th>\u7a7a\u8c03\u4ef7\u683c(\u5143)<\/th>\n        <th>\u5730\u6696\u4ef7\u683c(\u5143)<\/th>\n        <th>\u603b\u4ef7(\u5143)<\/th>\n        <th>\u603b\u4ef7(\u4e07)<\/th>\n        <th>\u9884\u7b97\u5339\u914d<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td>\u65b9\u6848A+\u6c34\u6a21\u5757\u5730\u6696\u8282\u80fd<\/td>\n        <td>\u5929\u6c1f\u5730\u6c34<\/td>\n        <td>\u6c34\u6a21\u5757+\u8282\u80fd\u7ba1\u8def<\/td>\n        <td>76,249<\/td>\n        <td>28,882<\/td>\n        <td>105,131<\/td>\n        <td>\u224810.5\u4e07<\/td>\n        <td><span class=\"lm-pill lm-pill-green\">\u5728\u9884\u7b97\u5185<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u65b9\u6848B+\u5730\u66961\u8282\u80fd<\/td>\n        <td>\u8212\u4eab\u6c1f\u673a<\/td>\n        <td>\u83f2\u65af\u66fc<\/td>\n        <td>52,160<\/td>\n        <td>43,079<\/td>\n        <td>95,239<\/td>\n        <td>\u22489.5\u4e07<\/td>\n        <td><span class=\"lm-pill lm-pill-blue\">\u4f4e\u4e8e\u9884\u7b97<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u65b9\u6848B+\u5730\u66962\u8282\u80fd<\/td>\n        <td>\u8212\u4eab\u6c1f\u673a<\/td>\n        <td>\u535a\u4e16<\/td>\n        <td>52,160<\/td>\n        <td>39,057<\/td>\n        <td>91,217<\/td>\n        <td>\u22489.1\u4e07<\/td>\n        <td><span class=\"lm-pill lm-pill-blue\">\u4f4e\u4e8e\u9884\u7b97<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u65b9\u6848B+\u5730\u66963\u8282\u80fd<\/td>\n        <td>\u8212\u4eab\u6c1f\u673a<\/td>\n        <td>\u66fc\u745e\u5fb7+\u70ed\u6c34\u5668<\/td>\n        <td>52,160<\/td>\n        <td>35,081+\u70ed\u6c34\u5668<\/td>\n        <td>87,241+\u70ed\u6c34\u5668<\/td>\n        <td>\u22488.7\u4e07<\/td>\n        <td><span class=\"lm-pill lm-pill-blue\">\u4f4e\u4e8e\u9884\u7b97<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td>\u65b9\u6848C+\u5730\u6696\u7ba1\u8def\u8282\u80fd<\/td>\n        <td>\u6c34\u5885\u9002FX<\/td>\n        <td>\u6c34\u673a+\u8282\u80fd\u7ba1\u8def<\/td>\n        <td>77,355<\/td>\n        <td>28,882<\/td>\n        <td>106,237<\/td>\n        <td>\u224810.6\u4e07<\/td>\n        <td><span class=\"lm-pill lm-pill-green\">\u5728\u9884\u7b97\u5185<\/span><\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"lm-ok-line\">\n    <strong>\u65b9\u6848\u9009\u578b\u5efa\u8bae\uff1a<\/strong>\u8463\u5148\u751f\u6838\u5fc3\u8bc9\u6c42\u662f\"\u51b2\u7740\u6c34\u673a\u8212\u9002\u5ea6\u6765\"\uff0c\u4e14\u6709\u5c0f\u5b69\u5bb6\u5ead\u3002\n    <ul>\n      <li><strong>\u9996\u9009\u65b9\u6848A+\u6c34\u6a21\u5757\u5730\u6696\uff08\u224810.5\u4e07\uff09<\/strong>\uff1a\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7+\u6c34\u6a21\u5757\u5e26\u5730\u6696\uff0c\u65e0\u9505\u7089\u70e7\u6c14\uff0c\u8fd0\u884c\u8d39\u66f4\u4f4e\u3002\u65e5\u7acb\u539f\u5382\u6574\u5957\u7ef4\u4fdd\u65e0\u5fe7\uff0c\u572810-13\u4e07\u9884\u7b97\u5185\u3002<\/li>\n      <li><strong>\u6b21\u9009\u65b9\u6848C\uff08\u224810.6\u4e07\uff09<\/strong>\uff1a\u51fa\u98ce\u6700\u67d4\u548c\uff0c\u6c34\u673a\u70ed\u6cf5\u76f4\u63a5\u5e26\u5730\u6696\uff0c\u65e0\u9700\u9505\u7089\u3002\u4f46\u53a8\u623f\u4e0d\u88c5\u7a7a\u8c03\u3001\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\u3001\u96f6\u8d8a\u5185\u673a\u975e\u65e5\u7acb\u539f\u5382\u3002<\/li>\n      <li><strong>\u7ecf\u6d4e\u9009\u65b9\u6848B+\u5730\u66962\/3\uff08\u22488.7-9.1\u4e07\uff09<\/strong>\uff1a\u6027\u4ef7\u6bd4\u6700\u9ad8\uff0c\u8d85\u914d\u7387\u5b89\u5168\uff0c\u65e5\u7acb\u4e94\u7ef4\u4e00\u4f53\u68c0\u6d4b\u6e29\u5ea6\u6280\u672f\u8212\u9002\u5ea6\u4f18\u4e8e\u5176\u4ed6\u54c1\u724c\u6c1f\u673a\u3002\u9700\u914d\u72ec\u7acb\u9505\u7089\u5730\u6696\u3002<\/li>\n    <\/ul>\n  <\/div>\n\n  <h3 id=\"s3-20yr\">20\u5e74\u603b\u8d26\u4f30\u7b97<\/h3>\n  <p>\u4ee5\u65b9\u6848A+\u6c34\u6a21\u5757\u5730\u6696\u8282\u80fd\u3001\u65b9\u6848B+\u5730\u66962\u8282\u80fd\u3001\u65b9\u6848C\u4e09\u7ec4\u5bf9\u6bd4\uff0c\u4f30\u7b9720\u5e74\u5168\u751f\u547d\u5468\u671f\u603b\u8d39\u7528\u3002\u8fd0\u884c\u8d39\u7528\u4e3a\u4f30\u7b97\u53c2\u8003\u503c\uff0c\u5b9e\u9645\u53d6\u51b3\u4e8e\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\/\u7535\u4ef7\u6ce2\u52a8\u7b49\u56e0\u7d20\u3002\u70b9\u51fb\u5361\u7247\u67e5\u770b\u6a2a\u5411\u5806\u53e0\u5bf9\u6bd4\u56fe\u3002<\/p>\n\n  <div class=\"lm-flip-card\" id=\"costCard\" onclick=\"this.classList.toggle('flipped')\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\">\n        <div class=\"lm-geo-card\" style=\"margin:0; height:100%;\">\n          <h4>20\u5e74\u603b\u8d26\u8ba1\u7b97\u516c\u5f0f\uff08\u663e\u5f0f\uff09<\/h4>\n          <p><strong>20\u5e74\u603b\u8d26 = \u521d\u59cb\u8bbe\u5907+\u5b89\u88c5\uff08\u4e00\u6b21\u6027\uff09 \uff0b \u5e74\u8fd0\u884c\u5408\u8ba1 \u00d7 20\u5e74 \uff0b 20\u5e74\u4e2d\u95f4\u7ef4\u62a4\uff08\u66f4\u6362\u8017\u6750\u7b49\uff09<\/strong><\/p>\n          <ul>\n            <li><strong>\u53d8\u91cf\u2460\u521d\u59cb\u6295\u8d44 C\u2080<\/strong>\uff1a\u8bbe\u5907\u9762\u4ef7 + \u5b89\u88c5\u8d39<\/li>\n            <li><strong>\u53d8\u91cf\u2461\u5e74\u8fd0\u884c\u8d39 R<\/strong>\uff1a\u5e74\u7a7a\u8c03\u7535\u8d39 + \u5e74\u5730\u6696\u8d39\uff08\u71c3\u6c14\/\u7535\u8d39\uff09+ \u5e74\u7ef4\u62a4\u8d39<\/li>\n            <li><strong>\u53d8\u91cf\u2462\u4e2d\u95f4\u7ef4\u62a4 M<\/strong>\uff1a20\u5e74\u5468\u671f\u5185\u6ee4\u7f51\/\u8017\u6750\/\u90e8\u4ef6\u66f4\u6362\u4f30\u7b97<\/li>\n            <li><strong>\u4ee3\u5165\u793a\u4f8b\uff08\u65b9\u6848A\u53d6\u533a\u95f4\u4e2d\u503c\uff09<\/strong>\uff1aC\u2080=105,131\u5143\uff1bR\u22486,000\u5143\/\u5e74 \u2192 R\u00d720=120,000\u5143\uff1bM\u224815,000\u5143\u3002<br>\u5408\u8ba1 \u2248 105,131 + 120,000 + 15,000 = <strong>240,131\u5143 \u2248 24.0\u4e07<\/strong>\uff08\u843d\u5728\u4e0b\u56fe 22.0\u201326.0\u4e07\u533a\u95f4\u5185\uff09<\/li>\n          <\/ul>\n          <div class=\"lm-flip-hint\">\ud83d\udca1 \u70b9\u51fb\u5361\u7247\u67e5\u770b\u6a2a\u5411\u5806\u53e0\u5bf9\u6bd4\u56fe<\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"lm-flip-back\">\n        <div class=\"lm-chart-wrap\" style=\"margin:0; height:100%;\">\n          <h4>20\u5e74\u603b\u8d26\u6a2a\u5411\u5806\u53e0\u5bf9\u6bd4\uff08\u6309 \u521d\u6295 \/ \u8fd0\u884c \/ \u7ef4\u62a4 \/ \u66f4\u6362 \u56db\u53d8\u91cf\uff09<\/h4>\n          <p style=\"text-align:center; font-size:12px; color:var(--text-light); margin:0 0 16px;\">\u4ee5\u5404\u65b9\u6848\u53d6\u533a\u95f4\u4e2d\u503c\u8ba1\u7b97\uff0c\u6761\u957f\u4ee3\u886820\u5e74\u603b\u82b1\u8d39\uff1b\u66f4\u6362\u8d39=0\uff08\u4e3b\u673a\u4e0e\u5730\u6696\u7ba1\u5bff\u547d20\u5e74+\uff09\u3002<\/p>\n\n          <div class=\"lm-cost-chart\">\n            <div class=\"lm-cost-row\">\n              <div class=\"lm-cost-label\">\u65b9\u6848A<\/div>\n              <div class=\"lm-cost-bar\">\n                <div class=\"lm-cost-seg init\" style=\"width:39.8%\" title=\"\u521d\u6295 10.51\u4e07\"><\/div>\n                <div class=\"lm-cost-seg run\" style=\"width:45.4%\" title=\"\u8fd0\u884c 12.0\u4e07\"><\/div>\n                <div class=\"lm-cost-seg maint\" style=\"width:5.7%\" title=\"\u7ef4\u62a4 1.5\u4e07\"><\/div>\n              <\/div>\n              <div class=\"lm-cost-total\">\u224824.0\u4e07<\/div>\n            <\/div>\n            <div class=\"lm-cost-row\">\n              <div class=\"lm-cost-label\">\u65b9\u6848B<\/div>\n              <div class=\"lm-cost-bar\">\n                <div class=\"lm-cost-seg init\" style=\"width:34.5%\" title=\"\u521d\u6295 9.12\u4e07\"><\/div>\n                <div class=\"lm-cost-seg run\" style=\"width:60.9%\" title=\"\u8fd0\u884c 16.1\u4e07\"><\/div>\n                <div class=\"lm-cost-seg maint\" style=\"width:4.5%\" title=\"\u7ef4\u62a4 1.2\u4e07\"><\/div>\n              <\/div>\n              <div class=\"lm-cost-total\">\u224826.4\u4e07<\/div>\n            <\/div>\n            <div class=\"lm-cost-row\">\n              <div class=\"lm-cost-label\">\u65b9\u6848C<\/div>\n              <div class=\"lm-cost-bar\">\n                <div class=\"lm-cost-seg init\" style=\"width:40.2%\" title=\"\u521d\u6295 10.62\u4e07\"><\/div>\n                <div class=\"lm-cost-seg run\" style=\"width:35.6%\" title=\"\u8fd0\u884c 9.4\u4e07\"><\/div>\n                <div class=\"lm-cost-seg maint\" style=\"width:7.6%\" title=\"\u7ef4\u62a4 2.0\u4e07\"><\/div>\n              <\/div>\n              <div class=\"lm-cost-total\">\u224822.0\u4e07<\/div>\n            <\/div>\n          <\/div>\n\n          <div class=\"lm-cost-legend\">\n            <span><i style=\"background:#8B2E2E\"><\/i>\u521d\u6295<\/span>\n            <span><i style=\"background:#D4A84B\"><\/i>\u8fd0\u884c\uff0820\u5e74\uff09<\/span>\n            <span><i style=\"background:#28a745\"><\/i>\u7ef4\u62a4\uff0820\u5e74\uff09<\/span>\n            <span><i style=\"background:#4a6fa5\"><\/i>\u66f4\u6362\uff080\uff09<\/span>\n          <\/div>\n          <div class=\"lm-flip-hint\">\ud83d\udca1 \u70b9\u51fb\u5361\u7247\u8fd4\u56de\u8ba1\u7b97\u516c\u5f0f<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-warn-line\">\n    <strong>20\u5e74\u603b\u8d26\u8bf4\u660e\uff1a<\/strong>\u65b9\u6848A\u6c34\u6a21\u5757\u5e26\u5730\u6696\u65e0\u9505\u7089\uff0c\u4e0e\u65b9\u6848C\u7c7b\u4f3c\uff0c\u8fd0\u884c\u8d39\u7528\u8fdc\u4f4e\u4e8e\u65b9\u6848B\u3002\u65b9\u6848A\u548c\u65b9\u6848C\u5730\u6696\u5747\u7531\u70ed\u6cf5\u9a71\u52a8\uff0c\u65e0\u9700\u70e7\u6c14\uff0c20\u5e74\u71c3\u6c14\u8d39\u4e3a0\u3002\u65b9\u6848B\u9700\u72ec\u7acb\u9505\u7089\u70e7\u6c14\uff0c\u5e74\u8fd0\u884c\u8d39\u9ad8\u51fa\u7ea62,000-3,000\u5143\/\u5e74\uff0c20\u5e74\u7d2f\u8ba1\u591a\u51fa\u7ea64-6\u4e07\u71c3\u6c14\u8d39\u3002\u4ee5\u4e0a\u4e3a\u4f30\u7b97\u53c2\u8003\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u4f7f\u7528\u4e60\u60ef\u3001\u80fd\u6e90\u4ef7\u683c\u6ce2\u52a8\u7b49\u5f71\u54cd\uff0c\u4e0d\u6784\u6210\u627f\u8bfa\u3002\n  <\/div>\n<\/section>\n\n<section id=\"s4\">\n  <h2>S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/h2>\n\n  <h3>\u516b\u5927\u65bd\u5de5\u9636\u6bb5<\/h3>\n  <table>\n    <thead>\n      <tr>\n        <th>\u9636\u6bb5<\/th>\n        <th>\u5de5\u5e8f\u540d\u79f0<\/th>\n        <th>\u65bd\u5de5\u5185\u5bb9<\/th>\n        <th>\u8d28\u91cf\u6807\u51c6<\/th>\n        <th>\u9a8c\u6536\u8282\u70b9<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td><strong>\u2460<\/strong><\/td>\n        <td>\u73b0\u573a\u52d8\u6d4b\u4e0e\u56fe\u7eb8\u4ea4\u5e95<\/td>\n        <td>\u4e0a\u95e8\u5b9e\u6d4b\u5404\u623f\u95f4\u5c3a\u5bf8\uff0c\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u5185\u673a\u4f4d\u3001\u7ba1\u9053\u8def\u7531\uff0c\u51fa\u5177\u65bd\u5de5\u56fe\u7eb8\uff0c\u4e0e\u88c5\u4fee\u56e2\u961f\u4ea4\u5e95<\/td>\n        <td>\u56fe\u7eb8\u4e0e\u73b0\u573a\u4e00\u81f4\uff0c\u6807\u9ad8\u3001\u9884\u7559\u5b54\u4f4d\u786e\u8ba4<\/td>\n        <td>\u56fe\u7eb8\u7b7e\u5b57\u786e\u8ba4<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2461<\/strong><\/td>\n        <td>\u4e3b\u7ba1\u9053\u5b89\u88c5<\/td>\n        <td>\u7a7a\u8c03\u51b7\u5a92\u94dc\u7ba1\u4e3b\u7ba1\u94fa\u8bbe\uff0c\u5730\u6696\u4e3b\u7ba1\uff08<strong>\u5fc5\u987b40\u7ba1<\/strong>\uff09\u94fa\u8bbe\uff0c\u5206\u6c34\u5668\u5b89\u88c5<\/td>\n        <td>\u94dc\u7ba1\u710a\u63a5\u65e0\u6f0f\u70b9\uff0c40\u4e3b\u7ba1\u6d41\u91cf\u6d4b\u8bd5\u901a\u8fc7\uff0c\u5761\u5ea6\u89c4\u8303<\/td>\n        <td>\u7ba1\u8def\u6253\u538b\u6d4b\u8bd5<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2462<\/strong><\/td>\n        <td>\u5185\u673a\u5b89\u88c5<\/td>\n        <td>7\u53f0\uff08\u65b9\u6848A\/B\uff09\u62166\u53f0\uff08\u65b9\u6848C\uff09\u5ba4\u5185\u673a\u540a\u88c5\uff0c\u51b7\u51dd\u6c34\u7ba1\u8fde\u63a5\uff0c\u98ce\u7ba1\u8fde\u63a5<\/td>\n        <td>\u5185\u673a\u6c34\u5e73\u5ea6\u22642mm\uff0c\u51cf\u9707\u57ab\u5230\u4f4d\uff0c\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22651%<\/td>\n        <td>\u5185\u673a\u6c34\u5e73+\u6392\u6c34\u6d4b\u8bd5<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2463<\/strong><\/td>\n        <td>\u5916\u673a\u5b89\u88c5<\/td>\n        <td>\u5916\u673a\u5c31\u4f4d\uff0c\u51cf\u9707\u57ab\u5b89\u88c5\uff0c\u4e0e\u4e3b\u7ba1\u9053\u8fde\u63a5\uff0c\u6c34\u6a21\u5757\/\u6c34\u529b\u5e73\u8861\u5668\u5b89\u88c5\uff08\u5982\u9002\u7528\uff09<\/td>\n        <td>\u5916\u673a\u6c34\u5e73\uff0c\u51cf\u9707\u5230\u4f4d\uff0c\u63a5\u53e3\u65e0\u6cc4\u6f0f\uff0c\u901a\u98ce\u95f4\u8ddd\u8fbe\u6807<\/td>\n        <td>\u5916\u673a\u56fa\u5b9a+\u63a5\u53e3\u68c0\u67e5<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2464<\/strong><\/td>\n        <td>\u7ba1\u9053\u8bd5\u538b<\/td>\n        <td>\u6c1f\u7cfb\u7edf\u4fdd\u538b\u68c0\u6f0f\uff08R410A\u89c4\u8303\u538b\u529b\uff09\uff0c\u6c34\u7cfb\u7edf\u6c34\u538b\u8bd5\u9a8c\uff081.5\u500d\u5de5\u4f5c\u538b\u529b\uff09<\/td>\n        <td>\u4fdd\u538b24h\u538b\u529b\u964d\u22640.02MPa\uff0c\u6c34\u538b\u65e0\u6e17\u6f0f<\/td>\n        <td><strong>\u8bd5\u538b\u62a5\u544a\u7b7e\u5b57<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2465<\/strong><\/td>\n        <td>\u5730\u6696\u94fa\u8bbe<\/td>\n        <td>\u4fdd\u6e29\u5c42\u94fa\u8bbe\uff0c\u5730\u6696\u7ba1\u94fa\u8bbe\uff08\u8282\u80fd\u578b\u7ba1\u95f4\u8ddd\uff09\uff0c\u56de\u586b\u5c42\u65bd\u5de5<\/td>\n        <td>\u7ba1\u95f4\u8ddd\u5747\u5300\uff0c\u4fdd\u6e29\u5c42\u65e0\u7834\u635f\uff0c\u56de\u586b\u5c42\u65e0\u7a7a\u9f13<\/td>\n        <td>\u5730\u6696\u6253\u538b+\u56de\u586b\u786e\u8ba4<\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2466<\/strong><\/td>\n        <td>\u7cfb\u7edf\u8c03\u8bd5<\/td>\n        <td>\u6c1f\u7cfb\u7edf\u62bd\u771f\u7a7a+\u5145\u6ce8\u51b7\u5a92\uff0c\u6c34\u7cfb\u7edf\u6c34\u529b\u5e73\u8861\u8c03\u8bd5\uff0c\u8054\u52a8\u63a7\u5236\u6a21\u5757\u8c03\u8bd5\uff0c\u6e29\u63a7\u5668\u914d\u5bf9<\/td>\n        <td>\u5404\u623f\u95f4\u6e29\u5ea6\u8fbe\u6807\uff0c\u8054\u52a8\u63a7\u5236\u6b63\u5e38\uff0c\u566a\u97f3\u226435dB(A)<\/td>\n        <td><strong>\u8c03\u8bd5\u62a5\u544a\u7b7e\u5b57<\/strong><\/td>\n      <\/tr>\n      <tr>\n        <td><strong>\u2467<\/strong><\/td>\n        <td>\u4ea4\u4ed8\u9a8c\u6536<\/td>\n        <td>\u5ba2\u6237\u73b0\u573a\u9a8c\u6536\uff0c\u4ea4\u4ed8\u4f7f\u7528\u624b\u518c\u3001\u4fdd\u4fee\u5361\u3001\u7ef4\u4fdd\u8ba1\u5212\uff0c\u57f9\u8bad\u65e5\u5e38\u4f7f\u7528<\/td>\n        <td>\u6240\u6709\u529f\u80fd\u6b63\u5e38\uff0c\u6587\u4ef6\u9f50\u5168\uff0c\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4<\/td>\n        <td><strong>\u4ea4\u4ed8\u9a8c\u6536\u7b7e\u5b57<\/strong><\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <p>\u9f99\u8109\u6696\u901a\u4e25\u683c\u6267\u884c\u6bcf\u4e2a\u9636\u6bb5\u9a8c\u6536\u8282\u70b9\u9700\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\u540e\u65b9\u53ef\u8fdb\u5165\u4e0b\u4e00\u9636\u6bb5\u3002\u8be6\u89c1<a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?p=1337\" target=\"_blank\">\u8f85\u6750\u914d\u7f6e\u6807\u51c6<\/a>\u3002<\/p>\n\n  <h3>\u65bd\u5de5\u5b9e\u666f\u56fe<\/h3>\n  <p>\u4ee5\u4e0b\u4e3a\u672c\u6848\u53ca\u76f8\u5173\u9879\u76ee\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6807\u51c6\u65bd\u5de5\u8282\u70b9\u5b9e\u62cd\uff0c\u7edf\u4e00\u6a2a\u56fe\u5c55\u793a\uff0c\u4fbf\u4e8e\u8463\u5148\u751f\u76f4\u89c2\u4e86\u89e3\u9690\u853d\u5de5\u7a0b\u8d28\u91cf\u3002<\/p>\n  <div class=\"lm-construct-gallery\">\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\" loading=\"lazy\">\n      <figcaption>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\" loading=\"lazy\">\n      <figcaption>\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xhmpqk.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\" loading=\"lazy\">\n      <figcaption>\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-frdl.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f\" loading=\"lazy\">\n      <figcaption>\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\" loading=\"lazy\">\n      <figcaption>\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6c2e\u6c14\u4fdd\u538b\u8868\" loading=\"lazy\">\n      <figcaption>\u6c2e\u6c14\u4fdd\u538b\u8868<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\" loading=\"lazy\">\n      <figcaption>\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\" loading=\"lazy\">\n      <figcaption>\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u58c1\u539a\" loading=\"lazy\">\n      <figcaption>\u94dc\u7ba1\u58c1\u539a\u68c0\u67e5<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u73b0\u573a\u8bbe\u5907\u6559\u5b66\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u8bbe\u5907\u6559\u5b66<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-construct-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\" loading=\"lazy\">\n      <figcaption>\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/figcaption>\n    <\/figure>\n  <\/div>\n\n  <h3>\u670d\u52a1\u627f\u8bfa<\/h3>\n  <div class=\"lm-promise-grid\">\n    <div class=\"lm-promise-card\">\n      <h4>\u5382\u5bb6\u8d28\u4fdd<\/h4>\n      <p>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\/\u6c34\u5885\u9002\u4e3b\u673a\u539f\u5382\u8d28\u4fdd\uff0c\u6838\u5fc3\u90e8\u4ef6\u53ef\u9760\u4fdd\u969c<\/p>\n    <\/div>\n    <div class=\"lm-promise-card\">\n      <h4>\u9f99\u8109\u5b89\u88c5\u8d28\u4fdd<\/h4>\n      <p>\u6210\u90fd22\u5e74\u672c\u5730\u6696\u901a\u670d\u52a1\u5546\uff0c\u7ba1\u8def\u6e17\u6f0f\u8d1f\u8d23\u5230\u5e95<\/p>\n    <\/div>\n    <div class=\"lm-promise-card\">\n      <h4>\u76d1\u7406\u9a8c\u6536<\/h4>\n      <p>\u5173\u952e\u8282\u70b9\u7b2c\u4e09\u65b9\u76d1\u7406\u9a8c\u6536\uff0c\u4e91\u7aef\u65bd\u5de5\u8bb0\u5f55\u53ef\u67e5<\/p>\n    <\/div>\n    <div class=\"lm-promise-card\">\n      <h4>\u4f1a\u5458\u5ef6\u4fdd<\/h4>\n      <p>\u4f1a\u5458\u53ef\u4eab\u5ef6\u4fdd\u6743\u76ca\uff0c\u51fa\u4fdd\u540e\u4e0d\u65ad\u6863<\/p>\n    <\/div>\n    <div class=\"lm-promise-card\">\n      <h4>\u6c1f\/\u6c34\u7cfb\u7edf\u4e13\u7cbe<\/h4>\n      <p>\u6c1f\u7cfb\u7edf\u4e0e\u6c34\u7cfb\u7edf\u540c\u5e97\u65bd\u5de5\uff0c\u7cfb\u7edf\u5339\u914d\u65e0\u626f\u76ae<\/p>\n    <\/div>\n    <div class=\"lm-promise-card\">\n      <h4>\u9759\u97f3\u4e13\u9879<\/h4>\n      <p>\u5367\u5ba4\u5355\u72ec\u8c03\u8bd5+\u566a\u97f3\u68c0\u6d4b\u62a5\u544a\uff0c\u786e\u4fdd\u9759\u97f3\u8fbe\u6807<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"s5\">\n  <h2>S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<\/h2>\n\n  <h3>\u6848\u4f8b\u53c2\u7167<\/h3>\n  <div class=\"lm-promise-grid\">\n    <div class=\"lm-promise-card\">\n      <h4>\u897f\u6d3e\u5c11\u57ce\u540c\u5c0f\u533a<\/h4>\n      <p>\u540c\u5c0f\u533a\u5df2\u6709\u9f99\u8109\u6696\u901a\u5b8c\u5de5\u6848\u4f8b\uff0c\u53ef\u73b0\u573a\u53c2\u89c2\u5b9e\u9645\u8fd0\u884c\u6548\u679c\u3002\u76f8\u540c\u5916\u5899\u4fdd\u6e29\u3001\u5c42\u9ad8\u7ed3\u6784\u3001\u6c14\u5019\u6761\u4ef6\uff0c\u4f53\u611f\u6570\u636e\u53ef\u76f4\u63a5\u53c2\u8003\u3002<\/p>\n    <\/div>\n    <a class=\"lm-promise-card\" href=\"https:\/\/longmai-nt.com\/?page_id=6949\" target=\"_blank\" style=\"text-decoration:none; color:inherit;\">\n      <h4>\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u6c84\u5cb8\u9ec4\u8001\u5e08\u5929\u6c1f\u5730\u6c34\u6848\u4f8b<\/h4>\n      <p>\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff1a\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u8fd0\u884c\u6548\u679c\u3001\u8d39\u7528\u6570\u636e\u4e0e\u7528\u6237\u4f53\u9a8c\uff0c\u53ef\u4f5c\u4e3a\u5929\u6c1f\u5730\u6c34\u65b9\u6848A\u7684\u53c2\u7167\u3002<\/p>\n    <\/a>\n    <a class=\"lm-promise-card\" href=\"https:\/\/longmai-nt.com\/?page_id=6029\" target=\"_blank\" style=\"text-decoration:none; color:inherit;\">\n      <h4>\u9ec4\u9f99\u6eaa\u8c37\u9f99\u6a3e\u53f0308\u33a1\u00b7\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u53cc\u4e3b\u673a\u5e76\u673a\u8282\u80fd\u7cfb\u7edf\u6848\u4f8b<\/h4>\n      <p>308\u33a1\u5927\u6237\u578b\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u53cc\u4e3b\u673a\u5e76\u673a\u8282\u80fd\u7cfb\u7edf\u6848\u4f8b\uff0c\u53ef\u4f5c\u4e3a\u65b9\u6848C\u5927\u7a7a\u95f4\u6c34\u7cfb\u7edf\u8212\u9002\u5ea6\u7684\u53c2\u7167\u3002<\/p>\n    <\/a>\n  <\/div>\n\n \n\n<section id=\"faq\">\n  <h2>\u5e38\u89c1\u95ee\u9898 FAQ<\/h2>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">260\u33a1\u5927\u5e73\u5c42\u9009\u6c34\u673a\u8fd8\u662f\u6c1f\u673a\uff1f\u54ea\u4e2a\u66f4\u8212\u670d\uff1f<\/div>\n    <div class=\"lm-faq-a\">\u6838\u5fc3\u533a\u522b\u5728\u590f\u5929\u672b\u7aef\u2014\u2014\u6c34\u673a\u51fa\u98ce15-17\u2103\u67d4\u548c\u3001\u6c1f\u673a\u51fa\u98ce7-10\u2103\u751f\u51b7\u3002\u5bb6\u91cc\u6709\u5c0f\u5b69\u3001\u540c\u5f00\u7387\u9ad8\uff0c\u6c34\u673a\u4f53\u611f\u66f4\u8212\u9002\u3002\u5982\u679c\u6ce8\u91cd\u81ea\u6e05\u6d01\u548c\u6e29\u6e7f\u7cbe\u51c6\u63a7\u5236\uff0c\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\u4e5f\u662f\u597d\u9009\u62e9\u3002\u8463\u5148\u751f\u73b0\u623f\u683c\u529b\u6c1f\u673a\"\u8d8a\u5439\u8d8a\u51b7\"\u7684\u4f53\u9a8c\u6b63\u662f\u6c1f\u673a\u51fa\u98ce\u6e29\u5dee\u5927\uff08\u5ba4\u6e2927\u2103\u2192\u51fa\u98ce7\u2103\uff0c\u6e29\u5dee20\u2103\uff09\u5bfc\u81f4\u7684\uff0c\u6c34\u673a\u901a\u8fc7\u4e8c\u6b21\u6362\u70ed\u5c06\u6e29\u5dee\u7f29\u5c0f\u523012\u2103\uff0c\u4f53\u611f\u81ea\u7136\u67d4\u548c\u5f88\u591a\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">\u65b9\u6848A\u8d85\u914d\u7387125.4%\u662f\u5426\u5b89\u5168\uff1f<\/div>\n    <div class=\"lm-faq-a\">\u65e5\u7acb\u6807\u51c6\u8d85\u914d\u4e0a\u9650130%\u3002\u65b9\u6848A\u8d85\u914d\u7387125.4%\uff0c\u5728\u6807\u51c6\u4e0a\u9650\u4ee5\u5185\uff0c\u9009\u578b\u5408\u7406\u3002\u4e66\u623f\u9009\u752818\u578b\u5185\u673a\uff081.8kW\uff09\u5339\u914d11.62\u33a1\u9762\u79ef\u3002\u5e38\u4f4f4\u4eba\u5927\u90e8\u5206\u65f6\u95f4\u4ec5\u90e8\u5206\u5185\u673a\u5f00\u542f\uff0c\u5b9e\u9645\u8fd0\u884c\u538b\u529b\u53ef\u63a7\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">\u5730\u6696\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u8981\u752840\u7ba1\u800c\u4e0d\u662f25\u7ba1\uff1f<\/div>\n    <div class=\"lm-faq-a\">170\u33a1\u4ee5\u4e0a\u5927\u6237\u578b\u5730\u6696\u9762\u79ef\u5927\uff0c25\u7ba1\u6d41\u91cf\u4e0d\u591f\uff0c\u9505\u7089\u53ea\u80fd\u9760\u63d0\u9ad8\u6c34\u6e29\u6765\u51d1\u2014\u2014\u51b7\u51dd\u7089\u53d8\u9ad8\u6e29\u70e7\uff0c\u8282\u80fd\u4f18\u52bf\u6ca1\u4e86\u300240\u4e3b\u7ba1\u786e\u4fdd\u8db3\u591f\u6d41\u91cf\uff0c\u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c\u624d\u8282\u80fd\u3002\u8463\u5148\u751f\u5730\u6696\u9762\u79ef170.9\u33a1\uff0c\u5c5e\u4e8e\u5927\u6237\u578b\uff0c25\u7ba1\u7684\u6c34\u963b\u529b\u592a\u5927\uff0c\u9505\u7089\u56de\u6c34\u6e29\u5ea6\u4e0a\u4e0d\u53bb\uff0c\u7cfb\u7edf\u4f1a\u81ea\u52a8\u63d0\u9ad8\u4f9b\u6c34\u6e29\u5ea6\u6765\u8865\u507f\uff0c\u51b7\u51dd\u7089\u7684\u51b7\u51dd\u6548\u7387\u4f18\u52bf\u5c31\u4e27\u5931\u4e86\u300240\u7ba1\u662f\u9f99\u8109\u6696\u901a\u5728170\u33a1\u4ee5\u4e0a\u9879\u76ee\u7684\u6807\u914d\u7ea2\u7ebf\uff0c\u4e0d\u53ef\u5546\u91cf\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\u548c\u4f20\u7edf\u4e24\u7528\u7089\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/div>\n    <div class=\"lm-faq-a\">\u4f20\u7edf\u4e24\u7528\u7089\u4e00\u53f0\u673a\u5668\u517c\u987e\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\uff0c\u51ac\u5929\u6d17\u6fa1\u65f6\u5730\u6696\u6e29\u5ea6\u53ef\u80fd\u6ce2\u52a8\u3002\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\uff1a24kW\u9505\u7089\u4e13\u804c\u5e26\u5730\u6696+\u53a8\u623f\u70ed\u6c34\uff0c16L\u70ed\u6c34\u5668\u4e13\u804c\u7ba1\u536b\u751f\u95f4\u70ed\u6c34\uff0c\u91c7\u6696\u70ed\u6c34\u5b8c\u5168\u5206\u79bb\u4e92\u4e0d\u5e72\u6270\u3002\u8463\u5148\u751f\u73b0\u623f\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5c31\u662f\u4e24\u7528\u7089\uff0c\u53ef\u80fd\u5b58\u5728\u6d17\u6fa1\u65f6\u5730\u6696\u6e29\u5ea6\u6ce2\u52a8\u7684\u95ee\u9898\u3002\u66fc\u745e\u5fb7\u5206\u79bb\u5f0f\u5f7b\u5e95\u89e3\u51b3\u8fd9\u4e2a\u95ee\u9898\uff0c\u800c\u4e14\u9505\u7089\u9762\u4ef7\u4ec55,599\u5143\uff0c\u6574\u4f53\u6027\u4ef7\u6bd4\u5f88\u9ad8\u300216L\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\u786e\u4fdd\u536b\u751f\u95f4\u79d2\u51fa\u70ed\u6c34\uff0c\u4f53\u9a8c\u66f4\u597d\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">\u53a8\u623f\u7a7a\u8c03\u600e\u4e48\u89e3\u51b3\uff1f9.67\u33a1\u80fd\u88c5\u5417\uff1f<\/div>\n    <div class=\"lm-faq-a\">\u65b9\u6848A\/B\u5747\u914d\u7f6eRCIS-22FSCN1QD\u53a8\u623f\u4e13\u7528\u5185\u673a\uff08\u4e00\u62d6\u591a\u7cfb\u7edf\u4e2d\u7684\u4e00\u53f0\uff09\uff0c\u9762\u4ef76,175\u5143\u3002\u53a8\u623f\u4e13\u7528\u673a\u9632\u6cb9\u6c61\u8bbe\u8ba1\uff0c\u5355\u72ec\u98ce\u9053\uff0c\u4e0d\u5f71\u54cd\u5176\u4ed6\u533a\u57df\u3002\u5982\u9884\u7b97\u7d27\u5f20\u4e5f\u53ef\u8003\u8651\u9001\u98ce\u53e3\u65b9\u6848\u3002\u53a8\u623f9.67\u33a1\uff0c\u51b7\u8d1f\u8377\u7ea62,901W\uff08300W\/\u33a1\uff09\uff0cRCIS-22\u578b\uff082.2kW\uff09\u57fa\u672c\u6ee1\u8db3\u3002\u9700\u8981\u6ce8\u610f\u53a8\u623f\u7a7a\u8c03\u5185\u673a\u9700\u5b9a\u671f\u6e05\u6d17\u6ee4\u7f51\uff08\u6cb9\u6c61\u6bd4\u7070\u5c18\u66f4\u96be\u6e05\u6d17\uff09\uff0c\u5efa\u8bae\u9009\u62e9\u4e13\u7528\u53a8\u623f\u673a\u578b\u800c\u975e\u666e\u901a\u5185\u673a\u3002\u65b9\u6848C\u6c34\u7cfb\u7edf\u56e0\u6c34\u98ce\u76d8\u4e0d\u9002\u5408\u6cb9\u6c61\u73af\u5883\uff0c\u53a8\u623f\u4e0d\u88c5\u7a7a\u8c03\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u54ea\u4e2a\u7ef4\u62a4\u6210\u672c\u66f4\u9ad8\uff1f<\/div>\n    <div class=\"lm-faq-a\">\u5929\u6c1f\u5730\u6c34\uff08\u6c1f\u7cfb\u7edf\uff09\u7ef4\u62a4\u6210\u672c\u4f4e\uff0c\u5236\u51b7\u5242\u4e00\u822c5-8\u5e74\u4e0d\u9700\u8981\u8865\u52a0\uff0c\u5185\u673a\u6ee4\u7f51\u6e05\u6d17\u5373\u53ef\u3002\u5929\u6c34\u5730\u6c34\uff08\u5168\u6c34\u7cfb\u7edf\uff09\u9700\u8981\u5b9a\u671f\u68c0\u67e5\u6c34\u8d28\u3001\u6c34\u8fc7\u6ee4\u5668\u3001\u81a8\u80c0\u7f50\u538b\u529b\uff0c\u51ac\u5b63\u9700\u505a\u9632\u51bb\u4fdd\u62a4\uff0c\u5e74\u7ef4\u62a4\u8d39\u7ea6\u6bd4\u6c1f\u7cfb\u7edf\u9ad8300-500\u5143\u3002\u4f46\u6c34\u7cfb\u7edf\u590f\u5b63\u66f4\u8282\u80fd\uff0c\u957f\u671f\u80fd\u8017\u66f4\u4f4e\u3002\u8463\u5148\u751f260\u33a1\u5927\u5e73\u5c42\u5982\u679c\u540c\u5f00\u7387\u9ad8\uff0c\u5929\u6c34\u5730\u6c34\u7684\u8282\u80fd\u6536\u76ca\u53ef\u8986\u76d6\u7ef4\u62a4\u5dee\u4ef7\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">31\u697c\u9ad8\u5c42\u5916\u673a\u4f4d\u600e\u4e48\u9009\uff1f\u566a\u97f3\u548c\u6563\u70ed\u6709\u5f71\u54cd\u5417\uff1f<\/div>\n    <div class=\"lm-faq-a\">31\u697c\u9ad8\u5c42\u9009\u5916\u673a\u4f4d\u8981\u5173\u6ce8\u4e09\u70b9\uff1a\u4e00\u662f\u907f\u5f00\u4e3b\u5367\u548c\u5973\u513f\u623f\u95f4\u65b9\u5411\u7684\u5899\u9762\uff0c\u51cf\u5c11\u4f4e\u9891\u5171\u632f\u566a\u97f3\u4f20\u5ba4\u5185\uff1b\u4e8c\u662f\u786e\u4fdd\u5916\u673a\u4f4d\u901a\u98ce\u6563\u70ed\u826f\u597d\uff0c\u907f\u514d\u590f\u5929\u9ad8\u6e29\u4fdd\u62a4\u505c\u673a\uff1b\u4e09\u662f\u5916\u673a\u4f4d\u5e94\u505a\u51cf\u9707\u57ab\u5904\u7406\uff08\u9f99\u8109\u6696\u901a\u6807\u914d\u6a61\u80f6\u51cf\u9707\u57ab+\u5f39\u7c27\u51cf\u9707\u5668\uff09\u3002\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u5916\u673a\u566a\u97f3\u4ec556dB(A)\uff0c31\u697c\u5b89\u88c5\u5728\u5185\u673a\u8fdc\u79bb\u5367\u5ba4\u4e00\u4fa7\uff0c\u5ba4\u5185\u5b9e\u6d4b\u566a\u97f3\u53ef\u63a7\u5236\u572835dB(A)\u4ee5\u4e0b\u3002\u65b9\u6848C\u6c34\u7cfb\u7edf\u5916\u673a\u66f4\u91cd\uff08\u7ea6120kg\uff09\uff0c\u5b89\u88c5\u524d\u9700\u786e\u8ba4\u5916\u673a\u4f4d\u627f\u91cd\u3002<\/div>\n  <\/div>\n\n  <div class=\"lm-faq-item\">\n    <div class=\"lm-faq-q\">260\u33a1\u5927\u5e73\u5c42\u6709\u5fc5\u8981\u88c5\u65b0\u98ce\u7cfb\u7edf\u5417\uff1f\u98ce\u91cf\u600e\u4e48\u9009\uff1f<\/div>\n    <div class=\"lm-faq-a\">260\u33a1\u5927\u5e73\u5c42\u5bc6\u5c01\u6027\u597d\uff0c\u81ea\u7136\u901a\u98ce\u4e0d\u8db3\uff0c\u5efa\u8bae\u88c5\u65b0\u98ce\u3002\u6309\u5c42\u9ad82.8m\u8ba1\u7b97\uff0c\u5ba4\u5185\u4f53\u79ef\u7ea6728m\u00b3\uff0c\u6bcf\u5c0f\u65f6\u6362\u6c140.5-0.7\u6b21\u9700\u98ce\u91cf350-500m\u00b3\/h\u3002\u672c\u65b9\u6848\u63a8\u8350\u65e5\u7acb\u4e91\u51c0\u2161\uff08500m\u00b3\/h\uff09\u6216\u5929\u51c0Q5\uff08350m\u00b3\/h\uff09\uff0c\u53ef\u6839\u636e\u5e38\u4f4f\u4eba\u53e3\u548c\u5367\u5ba4\u6570\u91cf\u9009\u62e9\u3002\u88c5\u4e86\u65b0\u98ce\u540e\u53ef\u5173\u7a97\u964d\u566a\uff0c\u914d\u5408\u7a7a\u8c03\u9664\u6e7f\uff0c\u5927\u5e73\u5c42\u4f53\u611f\u63d0\u5347\u660e\u663e\u3002\u65b0\u98ce\u7ba1\u9053\u4e0e\u7a7a\u8c03\u7ba1\u9053\u540c\u671f\u65bd\u5de5\uff0c\u907f\u514d\u540e\u671f\u540a\u9876\u8fd4\u5de5\u3002<\/div>\n  <\/div>\n<\/section>\n\n<section id=\"links\">\n  <h2>\u5ef6\u4f38\u9605\u8bfb<\/h2>\n  <p>\u4e86\u89e3\u66f4\u591a\u6696\u901a\u4e13\u4e1a\u77e5\u8bc6\u548c\u9f99\u8109\u6696\u901a\u670d\u52a1\u6807\u51c6\uff0c\u8bf7\u8bbf\u95ee\u4ee5\u4e0b\u9875\u9762\uff1a<\/p>\n\n  <div class=\"lm-links\">\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161 \u2014\u2014 \u884c\u4e1a\u9996\u6b3e\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u7684\u4e2d\u592e\u7a7a\u8c03<\/a>\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb EX-\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\u624b\u518c<\/a>\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\">\u65e5\u7acb\u6c34\u5885\u9002\/\u4e24\u8054\u4f9b\/\u667a\u5885\u5168\u611f\u4e94\u6052\u7cfb\u7edf<\/a>\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=6949\" target=\"_blank\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u6c84\u5cb8\u9ec4\u8001\u5e08\u5929\u6c1f\u5730\u6c34\u6848\u4f8b<\/a>\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=6029\" target=\"_blank\">\u9ec4\u9f99\u6eaa\u8c37\u9f99\u6a3e\u53f0308\u33a1\u00b7\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u53cc\u4e3b\u673a\u5e76\u673a\u8282\u80fd\u7cfb\u7edf\u6848\u4f8b<\/a>\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=5809\" target=\"_blank\">\u9e93\u6e56\u6c84\u5cb8157\u33a1\u00b7\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b-\u65b0\u98ce\u70ed\u6c34-\u5168\u5c4b\u51c0\u6c34\u4e94\u6052\u7cfb\u7edf\u6848\u4f8b<\/a>\n    <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b<\/a>\n  <\/div>\n<\/section>\n\n<section id=\"certificates\">\n  <h2>\u54c1\u724c\u6388\u6743\u8bc1\u4e66<\/h2>\n  <p>\u9f99\u8109\u6696\u901a\u4e3a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5177\u5907\u591a\u7ea7\u522b\u5b89\u88c5\u4e0e\u670d\u52a1\u8d44\u8d28\uff0c\u4ee5\u4e0b\u6388\u6743\u8bc1\u4e66\u4f9b\u8463\u5148\u751f\u67e5\u9a8c\u3002<\/p>\n\n  <div class=\"lm-cert-strip\">\n    <figure class=\"lm-cert-strip-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\uff082026\uff09\" loading=\"lazy\">\n      <figcaption>\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\uff082026\uff09<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-cert-strip-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\uff082024\uff09\" loading=\"lazy\">\n      <figcaption>\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\uff082024\uff09<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-cert-strip-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u6388\u6743\" loading=\"lazy\">\n      <figcaption>\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-cert-strip-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\uff082026\uff09\" loading=\"lazy\">\n      <figcaption>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\uff082026\uff09<\/figcaption>\n    <\/figure>\n    <figure class=\"lm-cert-strip-item\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66\uff082026\uff09\" loading=\"lazy\">\n      <figcaption>\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66\uff082026\uff09<\/figcaption>\n    <\/figure>\n  <\/div>\n<\/section>\n\n<section id=\"showroom\">\n  <div class=\"lm-showroom\">\n    <div class=\"lm-showroom-head\">\n      <h2>\ud83d\udcde \u6b22\u8fce\u54a8\u8be2<\/h2>\n      <p>\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u91cf\u8eab\u5b9a\u5236\u7a7a\u8c03\u65b9\u6848 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5<\/p>\n    <\/div>\n\n    <div class=\"lm-showroom-contacts\">\n      <a class=\"lm-showroom-contact\" href=\"tel:028-86131795\" target=\"_blank\">\n        <span class=\"icon\">\ud83d\udcf1<\/span><span>\u5357\u5bcc\u68ee\u5e97\uff1a028-86131795<\/span>\n      <\/a>\n      <a class=\"lm-showroom-contact\" href=\"tel:028-65272586\" target=\"_blank\">\n        <span class=\"icon\">\ud83d\udcf1<\/span><span>\u5317\u5bcc\u68ee\u5e97\uff1a028-65272586<\/span>\n      <\/a>\n    \n      \n      <a class=\"lm-showroom-contact\" href=\"tel:13908183204\" target=\"_blank\">\n        <span class=\"icon\">\ud83d\udc64<\/span><span>\u672c\u6848\u4f8b\u987e\u95ee\u4f59\u7231\u82f1\uff1a139-0818-3204<\/span>\n      <\/a>\n    <\/div>\n\n    <div class=\"lm-showroom-tags\">\n      <span class=\"lm-showroom-tag\">\u2705 \u4e0a\u95e8\u5b9e\u5730\u52d8\u6d4b<\/span>\n      <span class=\"lm-showroom-tag\">\u2705 \u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97<\/span>\n      <span class=\"lm-showroom-tag\">\u2705 \u4e13\u5c5e\u6237\u578b\u65b9\u6848\u62a5\u4ef7<\/span>\n      <span class=\"lm-showroom-tag\">\u2705 36\u9879\u65bd\u5de5\u8282\u70b9\u9a8c\u6536<\/span>\n    <\/div>\n\n    <div class=\"lm-showroom-shots\">\n      <figure class=\"lm-showroom-shot\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n        <figcaption>\n          <div class=\"store-name\">\ud83c\udfea \u5357\u5bcc\u68ee\u5e97<\/div>\n          <div class=\"store-addr\">\ud83d\udccd \u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/div>\n        <\/figcaption>\n      <\/figure>\n      <figure class=\"lm-showroom-shot\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n        <figcaption>\n          <div class=\"store-name\">\ud83c\udfea \u5317\u5bcc\u68ee\u5e97<\/div>\n          <div class=\"store-addr\">\ud83d\udccd \u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/div>\n        <\/figcaption>\n      <\/figure>\n    <\/div>\n\n    <div class=\"lm-showroom-coverage\">\n      \ud83d\uddfa\ufe0f \u6210\u90fd\u670d\u52a1\u8986\u76d6\u533a\u53bf\uff1a\u9ad8\u65b0\u3001\u6b66\u4faf\u3001\u6210\u534e\u3001\u9526\u6c5f\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u3001\u6e29\u6c5f\u3001\u65b0\u90fd\u7b49\u5168\u57df\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u65bd\u5de5\u3002\n    <\/div>\n\n    <div class=\"lm-showroom-cta\">\n      <a href=\"tel:13908183204\" target=\"_blank\">\u514d\u8d39\u9884\u7ea6\u52d8\u6d4b \u2192<\/a>\n    <\/div>\n\n    <div class=\"lm-showroom-note\">\n      * \u5177\u4f53\u8d39\u7528\u56e0\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u800c\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\n    <\/div>\n  <\/div>\n<\/section>\n\n<script>\n\/* ===== FAQ Accordion ===== *\/\ndocument.querySelectorAll('.lm-faq-item').forEach(function(item){\n  item.querySelector('.lm-faq-q').addEventListener('click', function(){\n    var isActive = item.classList.contains('active');\n    document.querySelectorAll('.lm-faq-item').forEach(function(i){ i.classList.remove('active'); });\n    if (!isActive) item.classList.add('active');\n  });\n});\n\n\/* ===== \u6c34\u673a vs \u6c1f\u673a \u96f7\u8fbe\u56fe ===== *\/\n(function(){\n  var ctx = document.getElementById('waterVsFreonChart');\n  if (!ctx || typeof Chart === 'undefined') return;\n  new Chart(ctx, {\n    type: 'radar',\n    data: {\n      labels: ['\u4f53\u611f\u8212\u9002\u5ea6','\u51fa\u98ce\u67d4\u548c\u5ea6','\u964d\u6e29\u901f\u5ea6','\u9664\u6e7f\u80fd\u529b','\u8fd0\u884c\u80fd\u8017','\u5b89\u88c5\u590d\u6742\u5ea6','\u7ef4\u62a4\u4fbf\u5229','\u5b89\u9759\u6027','\u9002\u5408\u8001\u4eba\/\u5c0f\u5b69'],\n      datasets: [\n        {\n          label: '\u6c1f\u673a\uff08\u76f4\u63a5\u84b8\u53d1\uff09',\n          data: [3, 2, 5, 5, 3, 4, 4, 3, 3],\n          borderColor: 'rgba(21,101,192,1)',\n          backgroundColor: 'rgba(21,101,192,0.15)',\n          pointBackgroundColor: 'rgba(21,101,192,1)',\n          borderWidth: 2\n        },\n        {\n          label: '\u6c34\u673a\uff08\u4e8c\u6b21\u6362\u70ed\uff09',\n          data: [5, 5, 3, 3, 4, 3, 3, 4, 5],\n          borderColor: 'rgba(40,167,69,1)',\n          backgroundColor: 'rgba(40,167,69,0.15)',\n          pointBackgroundColor: 'rgba(40,167,69,1)',\n          borderWidth: 2\n        }\n      ]\n    },\n    options: {\n      responsive: true,\n      maintainAspectRatio: true,\n      scales: {\n        r: {\n          min: 0,\n          max: 5,\n          ticks: { stepSize: 1, backdropColor: 'transparent' },\n          pointLabels: { font: { size: 12 } }\n        }\n      },\n      plugins: {\n        legend: { position: 'bottom' }\n      }\n    }\n  });\n})();\n\n\/* ===== \u4e5d\u7ef4\u5ea6\u96f7\u8fbe\u56fe ===== *\/\n(function(){\n  var ctx = document.getElementById('nineDimChart');\n  if (!ctx || typeof Chart === 'undefined') return;\n  new Chart(ctx, {\n    type: 'radar',\n    data: {\n      labels: ['\u8212\u9002\u5ea6','\u6e7f\u5ea6\u63a7\u5236','\u80fd\u6548\/\u8fd0\u884c\u8d39','\u521d\u59cb\u6295\u8d44','\u7ef4\u62a4\u4fbf\u5229','\u53ef\u9760\u6027','\u5b89\u88c5\u590d\u6742\u5ea6','\u81ea\u6e05\u6d01','\u9ad8\u6e29\u6740\u83cc'],\n      datasets: [\n        {\n          label: '\u65b9\u6848A \u5929\u6c1f\u5730\u6c34',\n          data: [5,5,4,4,4,5,3,5,5],\n          borderColor: 'rgba(21,101,192,1)',\n          backgroundColor: 'rgba(21,101,192,0.15)',\n          pointBackgroundColor: 'rgba(21,101,192,1)',\n          borderWidth: 2\n        },\n        {\n          label: '\u65b9\u6848B \u8212\u4eab\u6c1f\u673a',\n          data: [4,3,3,5,5,5,4,5,5],\n          borderColor: 'rgba(192,57,43,1)',\n          backgroundColor: 'rgba(192,57,43,0.12)',\n          pointBackgroundColor: 'rgba(192,57,43,1)',\n          borderWidth: 2\n        },\n        {\n          label: '\u65b9\u6848C \u5929\u6c34\u5730\u6c34',\n          data: [5,4,4,4,3,4,3,2,2],\n          borderColor: 'rgba(40,167,69,1)',\n          backgroundColor: 'rgba(40,167,69,0.12)',\n          pointBackgroundColor: 'rgba(40,167,69,1)',\n          borderWidth: 2\n        }\n      ]\n    },\n    options: {\n      responsive: true,\n      maintainAspectRatio: true,\n      scales: {\n        r: {\n          min: 0,\n          max: 5,\n          ticks: { stepSize: 1, backdropColor: 'transparent' },\n          pointLabels: { font: { size: 12 } }\n        }\n      },\n      plugins: {\n        legend: { position: 'bottom' }\n      }\n    }\n  });\n})();\n\n\/* ===== \u5b50\u76ee\u5f55\u4e0b\u62c9\u5bfc\u822a ===== *\/\n(function(){\n  var toggles = document.querySelectorAll('.lm-nav-toggle');\n  function closeAll(){\n    toggles.forEach(function(btn){\n      btn.setAttribute('aria-expanded', 'false');\n      var p = document.getElementById(btn.getAttribute('data-target'));\n      if (p) p.classList.remove('open');\n    });\n  }\n  toggles.forEach(function(btn){\n    btn.addEventListener('click', function(e){\n      e.stopPropagation();\n      var panel = document.getElementById(btn.getAttribute('data-target'));\n      var willOpen = !panel.classList.contains('open');\n      closeAll();\n      if (willOpen){\n        panel.classList.add('open');\n        btn.setAttribute('aria-expanded', 'true');\n      }\n    });\n  });\n  document.querySelectorAll('.lm-nav-panel a').forEach(function(a){\n    a.addEventListener('click', closeAll);\n  });\n  document.addEventListener('click', function(e){\n    if (!e.target.closest('.lm-nav-item')) closeAll();\n  });\n})();\n<\/script><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u524d\u4e66 \u897f\u6d3e\u5c11\u57ce \u00b7 \u8463 [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-7454","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u897f\u6d3e\u5c11\u57ce\u5927\u5e73\u5c42\u6696\u901a\u65b9\u6848\uff5c\u65e5\u7acb\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u5ea6\u5bf9\u6bd4<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u897f\u6d3e\u5c11\u57ce 260\u33a1\u5927\u5e73\u5c42\u65e5\u7acb\u6696\u901a\u5b8c\u6574\u65b9\u6848\uff0c\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\u6c1f\u673a\u4e09\u5957\u7a7a\u8c03 + \u5730\u6696\u7ec4\u5408\uff0c\u9488\u5bf9\u6709\u5b69\u5bb6\u5ead\u89e3\u51b3\u6c1f\u673a\u5439\u98ce\u751f\u51b7\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\u75db\u70b9\uff0c\u542b\u51b7\u8d1f\u8377\u6d4b\u7b97\u300110-13 \u4e07\u9884\u7b97\u62a5\u4ef7\u300120 \u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97\uff0c\u6807\u914d 40 \u4e3b\u7ba1\u5730\u6696\u8054\u52a8\uff0c\u539f\u5382\u6574\u5957\u65e5\u7acb\u8bbe\u5907\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u53ef\u5b9e\u5730\u770b\u6837\uff0c\u63d0\u4f9b\u540c\u5c0f\u533a\u5b8c\u5de5\u6848\u4f8b\u53c2\u89c2\uff0c\u542b\u6807\u51c6\u5316\u65bd\u5de5\u30016 \u5e74\u4e3b\u673a\u8d28\u4fdd\u4e0e\u7ec8\u8eab\u7ef4\u4fdd\u670d\u52a1\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=7454\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u897f\u6d3e\u5c11\u57ce\u5927\u5e73\u5c42\u6696\u901a\u65b9\u6848\uff5c\u65e5\u7acb\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u5ea6\u5bf9\u6bd4\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u897f\u6d3e\u5c11\u57ce 260\u33a1\u5927\u5e73\u5c42\u65e5\u7acb\u6696\u901a\u5b8c\u6574\u65b9\u6848\uff0c\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\u6c1f\u673a\u4e09\u5957\u7a7a\u8c03 + \u5730\u6696\u7ec4\u5408\uff0c\u9488\u5bf9\u6709\u5b69\u5bb6\u5ead\u89e3\u51b3\u6c1f\u673a\u5439\u98ce\u751f\u51b7\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\u75db\u70b9\uff0c\u542b\u51b7\u8d1f\u8377\u6d4b\u7b97\u300110-13 \u4e07\u9884\u7b97\u62a5\u4ef7\u300120 \u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97\uff0c\u6807\u914d 40 \u4e3b\u7ba1\u5730\u6696\u8054\u52a8\uff0c\u539f\u5382\u6574\u5957\u65e5\u7acb\u8bbe\u5907\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u53ef\u5b9e\u5730\u770b\u6837\uff0c\u63d0\u4f9b\u540c\u5c0f\u533a\u5b8c\u5de5\u6848\u4f8b\u53c2\u89c2\uff0c\u542b\u6807\u51c6\u5316\u65bd\u5de5\u30016 \u5e74\u4e3b\u673a\u8d28\u4fdd\u4e0e\u7ec8\u8eab\u7ef4\u4fdd\u670d\u52a1\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=7454\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-11T15:38:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454\",\"name\":\"\u897f\u6d3e\u5c11\u57ce\u5927\u5e73\u5c42\u6696\u901a\u65b9\u6848\uff5c\u65e5\u7acb\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u5ea6\u5bf9\u6bd4\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"datePublished\":\"2026-07-21T07:48:30+00:00\",\"dateModified\":\"2026-10-11T15:38:10+00:00\",\"description\":\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u897f\u6d3e\u5c11\u57ce 260\u33a1\u5927\u5e73\u5c42\u65e5\u7acb\u6696\u901a\u5b8c\u6574\u65b9\u6848\uff0c\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\u6c1f\u673a\u4e09\u5957\u7a7a\u8c03 + \u5730\u6696\u7ec4\u5408\uff0c\u9488\u5bf9\u6709\u5b69\u5bb6\u5ead\u89e3\u51b3\u6c1f\u673a\u5439\u98ce\u751f\u51b7\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\u75db\u70b9\uff0c\u542b\u51b7\u8d1f\u8377\u6d4b\u7b97\u300110-13 \u4e07\u9884\u7b97\u62a5\u4ef7\u300120 \u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97\uff0c\u6807\u914d 40 \u4e3b\u7ba1\u5730\u6696\u8054\u52a8\uff0c\u539f\u5382\u6574\u5957\u65e5\u7acb\u8bbe\u5907\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u53ef\u5b9e\u5730\u770b\u6837\uff0c\u63d0\u4f9b\u540c\u5c0f\u533a\u5b8c\u5de5\u6848\u4f8b\u53c2\u89c2\uff0c\u542b\u6807\u51c6\u5316\u65bd\u5de5\u30016 \u5e74\u4e3b\u673a\u8d28\u4fdd\u4e0e\u7ec8\u8eab\u7ef4\u4fdd\u670d\u52a1\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"width\":1754,\"height\":1240},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7454#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8463\u5148\u751f\u6696\u901a\u65b9\u6848\u524d\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u897f\u6d3e\u5c11\u57ce\u5927\u5e73\u5c42\u6696\u901a\u65b9\u6848\uff5c\u65e5\u7acb\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u5ea6\u5bf9\u6bd4","description":"\u6210\u90fd\u9f99\u8109\u6696\u901a\u897f\u6d3e\u5c11\u57ce 260\u33a1\u5927\u5e73\u5c42\u65e5\u7acb\u6696\u901a\u5b8c\u6574\u65b9\u6848\uff0c\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\u6c1f\u673a\u4e09\u5957\u7a7a\u8c03 + \u5730\u6696\u7ec4\u5408\uff0c\u9488\u5bf9\u6709\u5b69\u5bb6\u5ead\u89e3\u51b3\u6c1f\u673a\u5439\u98ce\u751f\u51b7\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\u75db\u70b9\uff0c\u542b\u51b7\u8d1f\u8377\u6d4b\u7b97\u300110-13 \u4e07\u9884\u7b97\u62a5\u4ef7\u300120 \u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97\uff0c\u6807\u914d 40 \u4e3b\u7ba1\u5730\u6696\u8054\u52a8\uff0c\u539f\u5382\u6574\u5957\u65e5\u7acb\u8bbe\u5907\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u53ef\u5b9e\u5730\u770b\u6837\uff0c\u63d0\u4f9b\u540c\u5c0f\u533a\u5b8c\u5de5\u6848\u4f8b\u53c2\u89c2\uff0c\u542b\u6807\u51c6\u5316\u65bd\u5de5\u30016 \u5e74\u4e3b\u673a\u8d28\u4fdd\u4e0e\u7ec8\u8eab\u7ef4\u4fdd\u670d\u52a1\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=7454","og_locale":"zh_CN","og_type":"article","og_title":"\u897f\u6d3e\u5c11\u57ce\u5927\u5e73\u5c42\u6696\u901a\u65b9\u6848\uff5c\u65e5\u7acb\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u5ea6\u5bf9\u6bd4","og_description":"\u6210\u90fd\u9f99\u8109\u6696\u901a\u897f\u6d3e\u5c11\u57ce 260\u33a1\u5927\u5e73\u5c42\u65e5\u7acb\u6696\u901a\u5b8c\u6574\u65b9\u6848\uff0c\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\u6c1f\u673a\u4e09\u5957\u7a7a\u8c03 + \u5730\u6696\u7ec4\u5408\uff0c\u9488\u5bf9\u6709\u5b69\u5bb6\u5ead\u89e3\u51b3\u6c1f\u673a\u5439\u98ce\u751f\u51b7\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\u75db\u70b9\uff0c\u542b\u51b7\u8d1f\u8377\u6d4b\u7b97\u300110-13 \u4e07\u9884\u7b97\u62a5\u4ef7\u300120 \u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97\uff0c\u6807\u914d 40 \u4e3b\u7ba1\u5730\u6696\u8054\u52a8\uff0c\u539f\u5382\u6574\u5957\u65e5\u7acb\u8bbe\u5907\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u53ef\u5b9e\u5730\u770b\u6837\uff0c\u63d0\u4f9b\u540c\u5c0f\u533a\u5b8c\u5de5\u6848\u4f8b\u53c2\u89c2\uff0c\u542b\u6807\u51c6\u5316\u65bd\u5de5\u30016 \u5e74\u4e3b\u673a\u8d28\u4fdd\u4e0e\u7ec8\u8eab\u7ef4\u4fdd\u670d\u52a1\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=7454","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-11T15:38:10+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"13 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=7454","url":"https:\/\/longmai-nt.com\/?page_id=7454","name":"\u897f\u6d3e\u5c11\u57ce\u5927\u5e73\u5c42\u6696\u901a\u65b9\u6848\uff5c\u65e5\u7acb\u5929\u6c34\u5730\u6c34 vs \u5929\u6c1f\u5730\u6c34\u5168\u7ef4\u5ea6\u5bf9\u6bd4","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=7454#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=7454#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","datePublished":"2026-07-21T07:48:30+00:00","dateModified":"2026-10-11T15:38:10+00:00","description":"\u6210\u90fd\u9f99\u8109\u6696\u901a\u897f\u6d3e\u5c11\u57ce 260\u33a1\u5927\u5e73\u5c42\u65e5\u7acb\u6696\u901a\u5b8c\u6574\u65b9\u6848\uff0c\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u3001\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\u6c1f\u673a\u4e09\u5957\u7a7a\u8c03 + \u5730\u6696\u7ec4\u5408\uff0c\u9488\u5bf9\u6709\u5b69\u5bb6\u5ead\u89e3\u51b3\u6c1f\u673a\u5439\u98ce\u751f\u51b7\u3001\u9505\u7089\u9891\u7e41\u542f\u505c\u75db\u70b9\uff0c\u542b\u51b7\u8d1f\u8377\u6d4b\u7b97\u300110-13 \u4e07\u9884\u7b97\u62a5\u4ef7\u300120 \u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97\uff0c\u6807\u914d 40 \u4e3b\u7ba1\u5730\u6696\u8054\u52a8\uff0c\u539f\u5382\u6574\u5957\u65e5\u7acb\u8bbe\u5907\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u53ef\u5b9e\u5730\u770b\u6837\uff0c\u63d0\u4f9b\u540c\u5c0f\u533a\u5b8c\u5de5\u6848\u4f8b\u53c2\u89c2\uff0c\u542b\u6807\u51c6\u5316\u65bd\u5de5\u30016 \u5e74\u4e3b\u673a\u8d28\u4fdd\u4e0e\u7ec8\u8eab\u7ef4\u4fdd\u670d\u52a1\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=7454#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=7454"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=7454#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","width":1754,"height":1240},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=7454#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u8463\u5148\u751f\u6696\u901a\u65b9\u6848\u524d\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7454","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7454"}],"version-history":[{"count":9,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7454\/revisions"}],"predecessor-version":[{"id":14699,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7454\/revisions\/14699"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7454"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}