{"id":7642,"date":"2026-07-22T17:31:21","date_gmt":"2026-07-22T09:31:21","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=7642"},"modified":"2026-07-25T09:04:54","modified_gmt":"2026-07-25T01:04:54","slug":"%e5%bc%a0%e5%85%88%e7%94%9f-%c2%b7-%e7%8f%91%e6%a8%be%e4%b8%80%e5%8f%b7-%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e4%ba%a4%e4%bb%98%e6%a1%88%e4%be%8b","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=7642","title":{"rendered":"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b"},"content":{"rendered":"\n\n<style>\n  :root{--deep-blue:#3a2c20;--gold:#c9a878;--gold-d:#a9824f;--blue:#3a2c20;--ink:#2e2620}\n  *{box-sizing:border-box}\n  html{scroll-behavior:smooth}\n  body{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;margin:0;color:var(--ink);line-height:1.75;background:#f6f2ec}\n  a{color:var(--deep-blue);text-decoration:none}\n  .lm-hero{position:relative;min-height:380px;background:#2a2018 url(\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-06.png\") center\/cover no-repeat;display:flex;flex-direction:column;justify-content:flex-end;color:#fff;padding:26px 20px}\n  .lm-hero::before{content:\"\";position:absolute;inset:0;background:linear-gradient(180deg,rgba(65,44,34,.28),rgba(65,44,34,.72))}\n  .lm-hero>*{position:relative;z-index:1}\n  .lm-hero .lm-eyebrow{font-size:.82rem;letter-spacing:2px;opacity:.9}\n  .lm-hero h1{margin:8px 0 6px;font-size:2.4rem!important;line-height:1.28;font-weight:800;color:#fff!important;letter-spacing:.5px;text-shadow:0 2px 14px rgba(0,0,0,.65);-webkit-text-stroke:.3px rgba(0,0,0,.25)}\n  .lm-hero h1 span{color:var(--gold);font-weight:800}\n  .lm-hero .lm-sub{font-size:.95rem;opacity:.95}\n  .lm-hero-info{display:flex;flex-wrap:wrap;gap:10px 22px;margin-top:16px}\n  .lm-hero-info .lm-it{min-width:88px}\n  .lm-hero-info .lm-lab{font-size:.72rem;opacity:.8}\n  .lm-hero-info .lm-val{font-size:.98rem;font-weight:700}\n  .lm-hero .lm-update{font-size:.72rem;opacity:.7;margin-top:10px}\n  .lm-toc{position:sticky;top:0;z-index:20;background:var(--deep-blue);display:flex;flex-wrap:wrap;gap:4px;padding:8px 12px;overflow:visible}\n  .lm-toc a{color:#fff;font-size:.76rem;white-space:nowrap;padding:5px 12px;border-radius:999px;background:rgba(255,255,255,.12)}\n  .lm-toc a:hover{background:rgba(255,255,255,.28)}\n  .lm-toc .lm-appendix{background:rgba(197,165,90,.35);font-weight:700}\n  .lm-section{max-width:820px;margin:0 auto;padding:26px 20px}\n  .lm-section h2{color:var(--deep-blue);font-size:1.12rem;margin:0 0 14px;padding-left:12px;border-left:5px solid var(--gold);line-height:1.5}\n  .lm-section h3{color:#3a302a;font-size:1.02rem;margin:18px 0 8px}\n  .lm-section{scroll-margin-top:54px}\n  table{border-collapse:collapse;width:100%;margin:12px 0;font-size:.88rem}\n  th,td{border:1px solid #e7ded2;padding:9px 11px;text-align:left;vertical-align:top}\n  th{background:#f1e9dc;color:var(--deep-blue);font-weight:700}\n  tr:nth-child(even) td{background:#faf6f0}\n  .lm-kv{display:grid;grid-template-columns:120px 1fr;gap:8px 14px;margin:10px 0;font-size:.92rem}\n  .lm-kv .lm-k{color:var(--deep-blue);font-weight:700}\n  .lm-hl{border:1px solid #e3d4bf;background:#f4ece0;border-radius:10px;padding:12px 16px;margin:12px 0}\n  .lm-hl b{color:var(--gold-d)}\n  .lm-ok{color:#2e8b57;font-weight:700;margin:8px 0}\n  .lm-note{background:#fff8e6;border:1px dashed #e0b84a;border-radius:8px;padding:10px 14px;font-size:.86rem;color:#7a5b00;margin:12px 0}\n  .lm-goals{margin:6px 0 14px;padding-left:22px;font-size:.92rem;line-height:1.85}\n  .lm-goals li{margin:5px 0}\n  .lm-goals b{color:var(--deep-blue)}\n  .lm-slider{margin:6px 0 4px}\n  .lm-section-tabs{display:flex;gap:6px;overflow-x:auto;padding-bottom:8px;border-bottom:2px solid #e7ded2}\n  .lm-section-tab{flex:0 0 auto;cursor:pointer;padding:8px 14px;border-radius:10px 10px 0 0;background:#f1e9dc;color:#8a7a64;font-size:.86rem;font-weight:600;border:1px solid #e7ded2;border-bottom:none;display:inline-block;font-family:inherit;line-height:1.2;margin:0;touch-action:manipulation;-webkit-user-select:none;user-select:none;-webkit-tap-highlight-color:transparent;transition:background .15s,color .15s}\n  .lm-section-tab.lm-active{background:var(--deep-blue);color:#fff}\n  .lm-content-card{display:none;padding:16px 4px 4px}\n  .lm-content-card.lm-active{display:block;animation:fade .25s ease}\n  @keyframes fade{from{opacity:0;transform:translateY(4px)}to{opacity:1;transform:none}}\n  .lm-card-title{font-weight:700;color:var(--deep-blue);margin-bottom:8px;font-size:1rem}\n  .lm-faq{margin:12px 0}\n  .lm-faq details{border:1px solid #e7ded2;border-radius:10px;margin-bottom:10px;background:#fff;overflow:hidden}\n  .lm-faq summary{padding:12px 16px;cursor:pointer;font-weight:600;color:var(--deep-blue);font-size:.94rem;list-style:none;-webkit-tap-highlight-color:transparent}\n  .lm-faq summary::-webkit-details-marker{display:none}\n  .lm-faq summary::before{content:\"Q\";display:inline-block;background:var(--gold);color:#fff;width:22px;height:22px;line-height:22px;text-align:center;border-radius:50%;margin-right:10px;font-size:.74rem;vertical-align:middle}\n  .lm-faq details[open] summary::before{content:\"\u2212\"}\n  .lm-faq .lm-faq-a{padding:0 16px 14px 48px;font-size:.9rem;color:#463c32;line-height:1.8}\n  .lm-cert-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:14px 0}\n  .lm-cert-grid figure{margin:0;background:#fff;border:1px solid #e7ded2;border-radius:10px;overflow:hidden;transition:box-shadow .2s}\n  .lm-cert-grid figure:hover{box-shadow:0 4px 16px rgba(58,44,32,.12)}\n  .lm-cert-img-wrap{width:100%;aspect-ratio:3\/2;overflow:hidden;background:#f4efe8;display:flex;align-items:center;justify-content:center}\n  .lm-cert-img-wrap img{width:100%;height:100%;object-fit:contain;padding:8px;display:block}\n  .lm-cert-grid figcaption{font-size:.78rem;color:#6b5f4f;padding:8px 10px;text-align:center;font-weight:600}\n  .lm-store-grid{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:14px 0}\n  .lm-store-grid figure{margin:0;border:1px solid #e7ded2;border-radius:12px;overflow:hidden;background:#fff;transition:box-shadow .2s}\n  .lm-store-grid figure:hover{box-shadow:0 4px 16px rgba(58,44,32,.12)}\n  .lm-store-img-wrap{width:100%;aspect-ratio:16\/9;overflow:hidden;background:#f4efe8}\n  .lm-store-img-wrap img{width:100%;height:100%;object-fit:cover;display:block}\n  .lm-store-grid figcaption{padding:12px 14px}\n  .lm-store-grid .lm-store-name{font-weight:700;color:#3a302a;font-size:.92rem;margin-bottom:6px}\n  .lm-store-grid .lm-addr{font-size:.8rem;color:#888;margin:2px 0;line-height:1.5}\n  .lm-foot{max-width:820px;margin:0 auto;padding:20px;font-size:.78rem;color:#9a8e7e;border-top:1px solid #e7ded2}\n  @media(max-width:560px){.lm-kv{grid-template-columns:92px 1fr}.lm-cert-grid{grid-template-columns:1fr}.lm-store-grid{grid-template-columns:1fr}.lm-hero h1{font-size:1.85rem!important;line-height:1.3}}\n  .lm-toc summary{list-style:none;cursor:pointer;color:#fff;font-size:.76rem;white-space:nowrap;padding:5px 12px;border-radius:999px;background:rgba(255,255,255,.12);display:inline-flex;align-items:center;-webkit-tap-highlight-color:transparent}\n  .lm-toc summary::-webkit-details-marker{display:none}\n  .lm-toc summary::after{content:\"\u25be\";margin-left:6px;font-size:.62rem;opacity:.8;transition:transform .2s}\n  .lm-toc details[open]>summary::after{content:\"\u25b4\"}\n  .lm-toc-item{position:relative}\n  .lm-toc-drop{display:none;position:absolute;top:calc(100% + 6px);left:0;z-index:30;min-width:200px;background:#fff;border:1px solid #e7ded2;border-radius:10px;box-shadow:0 8px 24px rgba(58,44,32,.18);padding:6px;flex-direction:column}\n  .lm-toc-item[open]>.lm-toc-drop{display:flex}\n  .lm-toc-drop a{display:block;color:#3a2c20;font-size:.82rem;padding:7px 12px;border-radius:7px;white-space:nowrap}\n  .lm-toc-drop a:hover{background:#f1e9dc}\n  .lm-toc-drop .lm-drop-sec{font-weight:700;border-bottom:1px solid #f1e9dc;margin-bottom:4px}\n  .lm-toc-drop .lm-drop-hi{background:rgba(197,165,90,.18);font-weight:600}\n  .lm-toc-drop .lm-drop-hi:hover{background:rgba(197,165,90,.3)}\n  .lm-cert-grid figure.lm-img-fail .lm-cert-img-wrap, .lm-store-grid figure.lm-img-fail .lm-store-img-wrap{position:relative;min-height:130px;background:#efe9e1}\n  .lm-cert-grid figure.lm-img-fail img, .lm-store-grid figure.lm-img-fail img{display:none}\n  .lm-cert-grid figure.lm-img-fail .lm-cert-img-wrap::after, .lm-store-grid figure.lm-img-fail .lm-store-img-wrap::after{content:\"\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d\\A\u8bf7\u7528\u624b\u673a\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\";white-space:pre;text-align:center;color:#8a7a52;font-size:.78rem;padding:16px;display:block}\n  .lm-links{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:14px 0}\n  .lm-links a{display:block;border:1px solid #e7ded2;border-left:4px solid var(--gold);border-radius:10px;padding:12px 14px;background:#fff;transition:.15s}\n  .lm-links a:hover{box-shadow:0 4px 14px rgba(197,165,90,.22);transform:translateY(-2px);background:#fdfbf4}\n  .lm-links .lm-lt{font-weight:700;color:var(--deep-blue);font-size:.92rem}\n  .lm-links .lm-ld{font-size:.8rem;color:#8a7e6c;margin-top:4px;line-height:1.5}\n  .lm-img-gallery{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:10px;margin:12px 0}\n  .lm-img-gallery figure{margin:0;border:1px solid #e7ded2;border-radius:8px;overflow:hidden;background:#fff;transition:box-shadow .2s}\n  .lm-img-gallery figure:hover{box-shadow:0 3px 12px rgba(58,44,32,.1)}\n  .lm-img-gallery .lm-img-wrap{width:100%;aspect-ratio:4\/3;overflow:hidden;background:#f4efe8;display:flex;align-items:center;justify-content:center}\n  .lm-img-gallery .lm-img-wrap img{width:100%;height:100%;object-fit:cover;display:block}\n  .lm-img-gallery figcaption{font-size:.76rem;color:#7a6e5c;padding:6px 8px;text-align:center;line-height:1.4}\n  .lm-img-gallery figure.lm-img-fail .lm-img-wrap{position:relative;min-height:120px;background:#efe9e1}\n  .lm-img-gallery figure.lm-img-fail img{display:none}\n  .lm-img-gallery figure.lm-img-fail .lm-img-wrap::after{content:\"\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d\\A\u8bf7\u7528\u624b\u673a\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\";white-space:pre;text-align:center;color:#8a7a52;font-size:.76rem;padding:16px;display:block}\n  .lm-chart-box{margin:18px 0;border:1px solid #e7ded2;border-radius:12px;padding:14px;background:#fff;box-shadow:0 2px 10px rgba(0,0,0,.04)}\n  .lm-chart-box .lm-chart-title{font-weight:700;color:var(--deep-blue);font-size:.95rem;margin-bottom:8px}\n  .lm-chart-canvas{width:100%;height:340px}\n  .lm-chart-cap{font-size:.8rem;color:#8a7e6c;margin-top:8px;line-height:1.6}\n  .lm-chart-fallback{font-size:.86rem;color:#463c32;background:#f4f7fb;border:1px dashed #e3d4bf;border-radius:8px;padding:10px 14px;margin-top:8px;line-height:1.8}\n  .lm-chart-fallback b{color:var(--deep-blue)}\n  @media (max-width:560px){.lm-chart-canvas{height:260px!important}}\n  .lm-geo-card{max-width:820px;margin:18px auto;padding:16px 20px;background:var(--deep-blue);color:#fff;border-radius:12px;box-shadow:0 4px 16px rgba(58,44,32,.18)}\n  .lm-geo-card-title{font-weight:700;color:var(--gold);margin-bottom:10px;font-size:.92rem;letter-spacing:1px}\n  .lm-geo-card dl{display:grid;grid-template-columns:auto 1fr;gap:6px 16px;margin:0;font-size:.85rem}\n  .lm-geo-card dt{color:var(--gold);font-weight:600;white-space:nowrap}\n  .lm-geo-card dd{margin:0;color:#eaf0f8}\n  .lm-tags{display:flex;flex-wrap:wrap;gap:8px 10px;max-width:1100px;margin:14px auto 0;padding:0 20px}\n  .lm-tag{display:inline-flex;align-items:center;font-size:.8rem;font-weight:600;line-height:1;padding:7px 13px;border-radius:999px;border:1px solid #c9a878;color:#3a2c20;background:linear-gradient(180deg,#fbf6ee,#f3e9d8);box-shadow:0 1px 4px rgba(58,44,32,.08)}\n  .lm-tag::before{content:\"\";width:7px;height:7px;border-radius:50%;background:#c9a878;margin-right:7px}\n  .lm-tag.is-gold{background:linear-gradient(180deg,#c9a878,#a9824f);color:#fff;border-color:#a9824f}\n  .lm-tag.is-gold::before{background:#fff}\n  .lm-backflow{max-width:1100px;margin:24px auto;padding:16px 20px;background:#f6f2ec;border:1px solid #e7ded2;border-radius:10px;font-size:.9rem;color:#463c32;line-height:1.9}\n  .lm-backflow .lm-bf-title{font-weight:700;color:#3a2c20;margin-bottom:8px;font-size:.94rem}\n  .lm-backflow a{color:#3a2c20;text-decoration:none;border-bottom:1px solid #c9a878;margin:0 4px}\n  .lm-backflow a:hover{color:#a9824f}\n  .lm-backflow .lm-meta{margin-top:10px;font-size:.85rem;color:#6c5f4e}\n  .lm-flip-card{max-width:820px;margin:18px auto;perspective:1400px}\n  .lm-flip-card:focus{outline:2px solid var(--gold);outline-offset:3px}\n  .lm-flip-inner{position:relative;width:100%;min-height:360px;transition:transform .6s ease;transform-style:preserve-3d}\n  .lm-flip-card.flipped .lm-flip-inner{transform:rotateY(180deg)}\n  .lm-flip-front,.lm-flip-back{background:#f1e9dc;color:#3a2c20;border-radius:12px;box-shadow:0 4px 16px rgba(58,44,32,.12);backface-visibility:hidden;-webkit-backface-visibility:hidden;padding:16px 20px;width:100%;height:100%}\n  .lm-flip-front{position:relative}\n  .lm-flip-back{position:absolute;top:0;left:0;transform:rotateY(180deg);overflow:auto}\n  .lm-flip-title{font-weight:700;color:#a9824f;margin-bottom:10px;font-size:.92rem;letter-spacing:1px}\n  .lm-flip-front dl{display:grid;grid-template-columns:auto 1fr;gap:6px 16px;margin:0;font-size:.85rem}\n  .lm-flip-front dt{color:#3a2c20;font-weight:600;white-space:nowrap}\n  .lm-flip-front dd{margin:0;color:#243a5e}\n  .lm-flip-back .lm-goals{color:#243a5e;font-size:.9rem;line-height:1.8;margin:0;padding-left:20px}\n  .lm-flip-back .lm-goals b{color:#a9824f}\n  .lm-flip-back .lm-goals li{margin:6px 0}\n  .lm-flip-hint{margin-top:12px;font-size:.74rem;color:rgba(58,44,32,.6);text-align:right}\n  .lm-flip-front .lm-proj-list{display:grid;grid-template-columns:auto 1fr;gap:8px 16px;margin:0;font-size:.9rem}\n  .lm-flip-front .lm-proj-list dt{color:#3a2c20;font-weight:600;white-space:nowrap;margin:0}\n  .lm-flip-front .lm-proj-list dd{margin:0;color:#243a5e;line-height:1.6}\n  .lm-flip-back .lm-proj-intro{color:#243a5e;font-size:.92rem;line-height:1.95}\n  .lm-flip-back .lm-proj-intro p{margin:0 0 10px}\n  .lm-flip-back .lm-proj-intro p:last-child{margin-bottom:0}\n<\/style>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7150\u33a1\u8054\u6392\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u53cc\u7cfb\u7edf\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a\",\n      \"description\": \"\u4e3a\u5f20\u5148\u751f\u5728\u73d1\u6a3e\u4e00\u53f7\u4e09\u5c42\u8054\u6392\u522b\u5885\u4ea4\u4ed8\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff0c\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff08RAS-125+RAS-140\uff09\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\u3002\",\n      \"author\": {\"@type\": \"Person\",\"name\": \"\u9ec4\u52c7\",\"jobTitle\": \"\u6696\u901a\u65b9\u6848\u987e\u95ee\",\"worksFor\": {\"@type\": \"Organization\",\"name\": \"\u9f99\u8109\u6696\u901a\",\"url\": \"https:\/\/longmai-nt.com\"}},\n      \"datePublished\": \"2026-06-08\",\n      \"publisher\": {\"@type\": \"Organization\",\"name\": \"\u9f99\u8109\u6696\u901a\",\"url\": \"https:\/\/longmai-nt.com\"},\n      \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-vamzrbslgzllg-smkbl.jpg\",\n      \"contentLocation\": {\"@type\": \"Place\",\"name\": \"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\"}\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\"@type\": \"Question\",\"name\": \"\u4e09\u5c42\u8054\u6392\u522b\u5885\u4e3a\u4ec0\u4e48\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u800c\u4e0d\u662f\u4e00\u5957\u5927\u7cfb\u7edf\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5f20\u5148\u751f\u5bb6\u4e00\u697c\u4e0e\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\uff0c\u82e5\u7528\u4e00\u5957\u5927\u5916\u673a\u5e26\u5168\u697c\uff0c\u767d\u5929\u53ea\u5f00\u4e00\u697c\u4f1a\u51fa\u73b0\u5927\u9a6c\u62c9\u5c0f\u8f66\u3001\u65e0\u6548\u80fd\u8017\u3002\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff08\u4e00\u697c125\u5916\u673a+\u4e8c\u4e09\u697c140\u5916\u673a\uff09\uff0c\u767d\u5929\u5f00\u4e00\u697c\u5c0f\u673a\u3001\u665a\u4e0a\u5f00\u4e8c\u4e09\u697c\u4e2d\u673a\uff0c\u7cbe\u51c6\u5339\u914d\u751f\u6d3b\u8282\u594f\uff0c\u4e14\u4e00\u5957\u6545\u969c\u53e6\u4e00\u5957\u53ef\u5907\u7528\u3002\"}},\n        {\"@type\": \"Question\",\"name\": \"\u65e5\u7acb\u8212\u4eab\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\u662f\u600e\u4e48\u505a\u5230\u7684\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u91c7\u7528\u76f4\u6d41\u53d8\u9891\u98ce\u673a\u4e0e\u4f18\u5316\u98ce\u9053\u8bbe\u8ba1\uff0c\u6700\u4f4e\u8fd0\u884c\u566a\u97f317dB\uff08\u76f8\u5f53\u4e8e\u6811\u53f6\u6c99\u6c99\u58f0\uff09\uff0c\u5367\u5ba4\u573a\u666f\u4f18\u5148\u9009\u7528\u4f4e\u566a\u97f3\u578b\u53f7\uff1b\u5916\u673a\u96c6\u4e2d\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\uff0c\u4e0e\u4f11\u606f\u533a\u5b8c\u5168\u5206\u79bb\uff0c\u53cc\u91cd\u4fdd\u969c\u9759\u97f3\u3002\"}},\n        {\"@type\": \"Question\",\"name\": \"\u4e24\u5957\u7cfb\u7edf\u4f1a\u4e0d\u4f1a\u6bd4\u4e00\u5957\u66f4\u8d39\u7535\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e0d\u4f1a\u3002\u6309\u9700\u5f00\u542f\u53cd\u66f4\u7701\u80fd\uff1a\u767d\u5929\u4ec5\u8fd0\u884c\u4e00\u697c\u5916\u673a\uff0c\u4e8c\u4e09\u697c\u7cfb\u7edf\u4f11\u7720\uff0c\u907f\u514d\u5927\u9a6c\u62c9\u5c0f\u8f66\u3002\u4e24\u5957\u7cfb\u7edf\u8d85\u914d\u7387101%\/109%\uff0c\u5747\u5904\u4e8e\u9ad8\u6548\u8fd0\u884c\u533a\u95f4\uff0c\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a\u4e14\u5bff\u547d\u66f4\u957f\u3002\"}},\n        {\"@type\": \"Question\",\"name\": \"\u697c\u9876\u5916\u673a\u566a\u97f3\u4f1a\u5f71\u54cd\u4f11\u606f\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u697c\u9876\u5e73\u53f0\u901a\u98ce\u6563\u70ed\u597d\u3001\u8ddd\u5367\u5ba4\u6700\u8fdc\uff0c\u5916\u673a\u8fd0\u884c\u566a\u97f3\u7ea654dB\u4e14\u8fdc\u79bb\u4f11\u606f\u533a\uff1b\u5367\u5ba4\u7aef\u753117dB\u5185\u673a\u9001\u98ce\uff0c\u566a\u97f3\u6e90\u5934\u4e0e\u4f11\u606f\u533a\u5b8c\u5168\u5206\u79bb\uff0c\u6ee1\u8db3\u566a\u97f3\u654f\u611f\u9700\u6c42\u3002\"}},\n        {\"@type\": \"Question\",\"name\": \"\u8d85\u914d\u7387101%\u548c109%\u5408\u4e0d\u5408\u7406\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8d85\u914d\u7387=\u5185\u673a\u603b\u51b7\u91cf\/\u5916\u673a\u51b7\u91cf\u3002\u4e00\u697c101%\u5904\u4e8e\u9ec4\u91d1\u533a\u95f4\u3001\u4e8c\u4e09\u697c109%\u5904\u4e8e\u5141\u8bb8\u533a\u95f4\uff08\u5141\u8bb8\u4e0a\u9650\u2264130%\uff09\uff0c\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a\uff0c\u7b26\u5408\u8bbe\u8ba1\u89c4\u8303\uff0c\u540c\u65f6\u517c\u987e\u4e0d\u540c\u65f6\u5f00\u7684\u4f7f\u7528\u4e60\u60ef\u3002\"}},\n        {\"@type\": \"Question\",\"name\": \"\u5730\u6696\u8981\u4e0d\u8981\u4e00\u8d77\u505a\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u672c\u6848\u4f8b\u4ee5\u4e2d\u592e\u7a7a\u8c03\u4e3a\u4e3b\uff0c\u5730\u6696\u9700\u6c42\u5f85\u4e0e\u5ba2\u6237\u786e\u8ba4\u3002\u5982\u540e\u671f\u52a0\u88c5\uff0c\u9f99\u8109\u53ef\u57fa\u4e8e\u73b0\u6709\u4e24\u5957\u7cfb\u7edf\u7684\u5916\u673a\u9884\u7559\u80fd\u529b\u4e0e\u6c34\u6a21\u5757\u63a5\u53e3\u6269\u5c55\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u65b9\u6848\u4e3a\u51c6\u3002\"}}\n      ]\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff08RAS-125HRNAQ + RAS-140HRNAQ + 6\u53f0RPIZ\u98ce\u7ba1\u673a\uff09\",\n      \"brand\": {\"@type\": \"Brand\",\"name\": \"\u65e5\u7acbHitachi\"},\n      \"description\": \"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff0c\u73d1\u6a3e\u4e00\u53f7\u4e09\u5c42\u8054\u6392\u522b\u5885\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u65b9\u6848\uff0c\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u9f99\u8109\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u4ea4\u4ed8\u3002\"\n    },\n    {\n      \"@type\": \"LocalBusiness\",\n      \"name\": \"\u9f99\u8109\u6696\u901a\",\n      \"url\": \"https:\/\/longmai-nt.com\",\n      \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\n      \"telephone\": \"028-86131795\",\n      \"areaServed\": \"\u6210\u90fd\u5168\u57df\uff08\u6b66\u4faf\u00b7\u9526\u6c5f\u00b7\u9752\u7f8a\u00b7\u91d1\u725b\u00b7\u6210\u534e\u00b7\u9ad8\u65b0\u00b7\u5929\u5e9c\u00b7\u53cc\u6d41\u00b7\u9f99\u6cc9\u00b7\u90eb\u90fd\u00b7\u6e29\u6c5f\u00b7\u65b0\u90fd\u00b7\u9752\u767d\u6c5f\uff09\",\n      \"address\": {\"@type\":\"PostalAddress\",\"addressLocality\":\"\u6210\u90fd\u5e02\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"streetAddress\":\"\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\"}\n    },\n    {\n      \"@type\": \"ImageObject\",\n      \"contentUrl\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-vamzrbslgzllg-smkbl.jpg\",\n      \"caption\": \"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u522b\u5885\u98ce\u7ba1\u673a\"\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"itemListElement\": [\n        {\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@id\":\"https:\/\/longmai-nt.com\",\"name\":\"\u9996\u9875\"}},\n        {\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@id\":\"https:\/\/longmai-nt.com\/?page_id=2297\",\"name\":\"\u5ba2\u6237\u6848\u4f8b\u5e93\"}},\n        {\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@id\":\"https:\/\/longmai-nt.com\/?page_id=2297\",\"name\":\"\u5f20\u5148\u751f\u00b7\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\"}}\n      ]\n    }\n  ]\n}\n<\/script>\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/echarts@5\/dist\/echarts.min.js\"><\/script>\n\n<header class=\"lm-hero\" data-case-id=\"LMC-202607-002\">\n  <div class=\"lm-eyebrow\">LONGMAI \u00b7 \u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6848\u4f8b<\/div>\n  <h1 style=\"font-size:2.4rem;font-weight:800;line-height:1.28;color:#fff;letter-spacing:.5px;text-shadow:0 2px 14px rgba(0,0,0,.65)\"><span>\u5f20\u5148\u751f<\/span> \u00b7 <span>\u73d1\u6a3e\u4e00\u53f7<\/span> \u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b<\/h1>\n  <div class=\"lm-sub\"><span>\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff08\u6309\u9700\u8282\u80fd\uff09<\/span> \u00b7 <span>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u6700\u4f4e17dB\u9759\u97f3<\/span> \u00b7 <span>\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4<\/span><\/div>\n  <div class=\"lm-update\">\u6848\u4f8b\u6574\u7406\u65f6\u95f4\uff1a2026\u5e746\u6708 &nbsp;|&nbsp; \u9f99\u8109\u6696\u901a\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5+2\u4ea4\u4ed8<\/div>\n<\/header>\n\n<div class=\"lm-tags\" aria-label=\"\u6848\u4f8b\u5dee\u5f02\u5316\u6807\u7b7e\">\n  <span class=\"lm-tag\">\u6309\u9700\u8282\u80fd\u53cc\u7cfb\u7edf<\/span>\n  <span class=\"lm-tag\">17dB \u6781\u81f4\u9759\u97f3<\/span>\n  <span class=\"lm-tag is-gold\">\u8d85\u914d\u7387 101% \u9ec4\u91d1\u533a\u95f4<\/span>\n  <span class=\"lm-tag is-gold\">\u6c2e\u6c14\u4fdd\u62a4\u710a\u7cbe\u5de5<\/span>\n<\/div>\n\n<nav class=\"lm-toc\">\n  <a href=\"#s1\">S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/a>\n  <a href=\"#s2\">S2 \u00b7 \u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad<\/a>\n  <details class=\"lm-toc-item\" name=\"lmsec\">\n    <summary>S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e<\/summary>\n    <div class=\"lm-toc-drop\">\n      <a href=\"#s3\" class=\"lm-drop-sec\">S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e<\/a>\n      <a href=\"#s3-1\">\u2460 \u7cfb\u7edf\u4e00 \u00b7 \u4e00\u697c<\/a>\n      <a href=\"#s3-2\">\u2461 \u7cfb\u7edf\u4e8c \u00b7 \u4e8c\/\u4e09\u697c<\/a>\n      <a href=\"#s3-3\">\u2462 \u6295\u5165\u6784\u6210<\/a>\n    <\/div>\n  <\/details>\n  <details class=\"lm-toc-item\" name=\"lmsec\">\n    <summary>S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u4fdd\u969c<\/summary>\n    <div class=\"lm-toc-drop\">\n      <a href=\"#s4\" class=\"lm-drop-sec\">S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u4fdd\u969c<\/a>\n      <a href=\"#s4-1\">\u2463 \u8bbe\u8ba1\u52d8\u6d4b<\/a>\n      <a href=\"#s4-2\">\u2464 \u5185\u673a\u5916\u673a\u5b89\u88c5<\/a>\n      <a href=\"#s4-3\">\u2465 \u8c03\u8bd5\u4ea4\u4ed8<\/a>\n    <\/div>\n  <\/details>\n  <details class=\"lm-toc-item\" name=\"lmsec\">\n    <summary>S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/summary>\n    <div class=\"lm-toc-drop\">\n      <a href=\"#s5\" class=\"lm-drop-sec\">S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/a>\n      <a href=\"#s5-1\" class=\"lm-drop-hi\">\u2466 \u914d\u7f6e\u8bca\u65ad<\/a>\n      <a href=\"#s5-2\" class=\"lm-drop-hi\">\u2467 \u516d\u7ef4\u8bc4\u5206<\/a>\n    <\/div>\n  <\/details>\n  <a href=\"#s6\" class=\"lm-appendix\">\u9ad8\u9891\u95ee\u9898<\/a>\n  <a href=\"#s7\" class=\"lm-appendix\">\u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97<\/a>\n<\/nav>\n\n<div class=\"lm-flip-card\" id=\"projCard\" tabindex=\"0\" role=\"button\" aria-label=\"\u70b9\u51fb\u7ffb\u8f6c\uff1a\u6b63\u9762\u4e3a\u5ba2\u6237\u9879\u76ee\u4fe1\u606f\uff0c\u80cc\u9762\u4e3a\u7cfb\u7edf\u4ecb\u7ecd\">\n  <div class=\"lm-flip-inner\">\n    <div class=\"lm-flip-front\">\n      <div class=\"lm-flip-title\">\u5ba2\u6237\u9879\u76ee\u4fe1\u606f<\/div>\n      <dl class=\"lm-proj-list\">\n        <dt>\u5ba2\u6237<\/dt><dd>\u5f20\u5148\u751f<\/dd>\n        <dt>\u9879\u76ee\u5730\u5740<\/dt><dd>\u73d1\u6a3e\u4e00\u53f7\uff08\u8054\u6392\u522b\u5885\u00b7\u4e09\u5c42\uff09<\/dd>\n        <dt>\u5efa\u7b51\u7c7b\u578b<\/dt><dd>\u4e09\u5c42\u8054\u6392\u522b\u5885 \u00b7 \u7a7a\u8c03\u8986\u76d6\u7ea6150\u33a1 \u00b7 \u5e38\u4f4f\u4eba\u53e34\u4eba<\/dd>\n        <dt>\u7cfb\u7edf\u7c7b\u578b<\/dt><dd>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff08\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff09<\/dd>\n        <dt>\u6838\u5fc3\u8bc9\u6c42<\/dt><dd>\u5236\u51b7\u4e3a\u4e3b\u3001\u566a\u97f3\u654f\u611f\u3001\u4e00\u697c\u4e0e\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\u3001\u62c5\u5fc3\u80fd\u8017<\/dd>\n        <dt>\u4eba\u7fa4\u6807\u7b7e<\/dt><dd>\u56db\u53e3\u4e4b\u5bb6 \u00b7 \u566a\u97f3\u654f\u611f\u578b\u4e1a\u4e3b<\/dd>\n        <dt>\u65b9\u6848\u987e\u95ee<\/dt><dd>\u9ec4\u52c7\uff0815828489188\uff09<\/dd>\n        <dt>\u6574\u7406\u65f6\u95f4<\/dt><dd>2026\u5e746\u6708<\/dd>\n      <\/dl>\n      <div class=\"lm-flip-hint\">\u70b9\u51fb\u7ffb\u8f6c \u2192 \u67e5\u770b\u7cfb\u7edf\u4ecb\u7ecd<\/div>\n    <\/div>\n    <div class=\"lm-flip-back\">\n      <div class=\"lm-flip-title\">\u7cfb\u7edf\u4ecb\u7ecd<\/div>\n      <div class=\"lm-proj-intro\">\n        <p>\u9f99\u8109\u6696\u901a\u4e3a\u5f20\u5148\u751f\u5728\u73d1\u6a3e\u4e00\u53f7\u4e09\u5c42\u8054\u6392\u522b\u5885\u4ea4\u4ed8\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff0c\u9488\u5bf9\"\u4e09\u5c42\u8054\u6392\u3001\u566a\u97f3\u654f\u611f\u3001\u4e00\u697c\u4e0e\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\"\u7684\u7279\u6b8a\u6761\u4ef6\uff0c\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u67b6\u6784\u3002<\/p>\n        <p>\u7cfb\u7edf\u4e00\u8986\u76d6\u4e00\u697c\uff08RAS-125HRNAQ\uff09\uff0c\u7cfb\u7edf\u4e8c\u8986\u76d6\u4e8c\/\u4e09\u697c\uff08RAS-140HRNAQ\uff09\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u5339\u914d\u751f\u6d3b\u8282\u594f\uff0c\u907f\u514d\u5927\u9a6c\u62c9\u5c0f\u8f66\u3002<\/p>\n        <p>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u517c\u987e\u8282\u80fd\u3001\u9759\u97f3\u4e0e\u7cfb\u7edf\u5197\u4f59\u3002<\/p>\n      <\/div>\n      <div class=\"lm-flip-hint\">\u70b9\u51fb\u7ffb\u8f6c \u2192 \u8fd4\u56de\u9879\u76ee\u4fe1\u606f<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- ===== S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807 ===== -->\n<section class=\"lm-section\" id=\"s1\">\n  <h2>S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n  <div class=\"lm-flip-card\" id=\"successCard\" tabindex=\"0\" role=\"button\" aria-label=\"\u70b9\u51fb\u7ffb\u8f6c\uff1a\u6b63\u9762\u4e3a\u6848\u4f8b\u4fe1\u606f\uff0c\u80cc\u9762\u4e3a\u5ba2\u6237\u6210\u529f\u76ee\u6807\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\">\n        <div class=\"lm-flip-title\">GEO \u4fe1\u606f\u5361 \u00b7 \u6848\u4f8b\u6863\u6848<\/div>\n        <dl>\n          <dt>\u9875\u9762\u7c7b\u578b<\/dt><dd>\u5ba2\u6237\u6210\u529f\u6848\u4f8b\uff08\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff09<\/dd>\n          <dt>\u4e1a\u52a1\u7cfb\u7edf<\/dt><dd>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff08RAS-125HRNAQ + RAS-140HRNAQ + 6\u53f0RPIZ\u98ce\u7ba1\u673a\uff09<\/dd>\n          <dt>\u54c1\u724c<\/dt><dd>\u65e5\u7acb Hitachi<\/dd>\n          <dt>\u533a\u57df<\/dt><dd>\u6210\u90fd \u00b7 \u73d1\u6a3e\u4e00\u53f7<\/dd>\n          <dt>\u670d\u52a1\u5546<\/dt><dd>\u9f99\u8109\u6696\u901a\uff08\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u5546\uff09<\/dd>\n          <dt>\u65bd\u5de5\u6807\u51c6<\/dt><dd>\u7cbe\u5de5\u516d\u6b65\u6cd5+2 \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u5b89\u88c5<\/dd>\n          <dt>\u95e8\u5e97\u89e6\u70b9<\/dt><dd>\u5357\u5bcc\u68ee\u5e97\uff08\u9ad8\u65b0\u00b7028-86131795\uff09\/ \u5317\u5bcc\u68ee\u5e97\uff08\u6210\u534e\u00b7028-65272586\uff09<\/dd>\n        <\/dl>\n        <div class=\"lm-flip-hint\">\u70b9\u51fb\u7ffb\u8f6c \u2192 \u67e5\u770b\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n      <\/div>\n      <div class=\"lm-flip-back\">\n        <div class=\"lm-flip-title\">\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n        <ol class=\"lm-goals\">\n          <li><b><span>\u6309\u9700\u8282\u80fd<\/span>\uff1a<\/b><span>\u4e00\u697c\u4e0e\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\uff0c\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff0c\u767d\u5929\u5f00\u4e00\u697c\u5c0f\u673a\u3001\u665a\u4e0a\u5f00\u4e8c\u4e09\u697c\u4e2d\u673a\uff0c\u907f\u514d\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u7684\u65e0\u6548\u80fd\u8017\uff08\u9a8c\u8bc1\uff1a\u8d85\u914d\u7387101%\/109%\u5747\u5904\u9ad8\u6548\u533a\u95f4\uff09\u3002<\/span><\/li>\n          <li><b><span>\u9759\u97f3\u8212\u9002<\/span>\uff1a<\/b><span>\u566a\u97f3\u654f\u611f\u3001\u6015\u5f71\u54cd\u7761\u7720\u3002\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u6700\u4f4e17dB\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u566a\u97f3\u6e90\u5934\u4e0e\u4f11\u606f\u533a\u5b8c\u5168\u5206\u79bb\uff08\u9a8c\u8bc1\uff1a\u5185\u673a17dB \u2248 \u6811\u53f6\u6c99\u6c99\u58f0\uff09\u3002<\/span><\/li>\n          <li><b><span>\u7cfb\u7edf\u5197\u4f59<\/span>\uff1a<\/b><span>\u62c5\u5fc3\u7cfb\u7edf\u53ef\u9760\u6027\u3002\u4e24\u5957\u7cfb\u7edf\u4e92\u4e3a\u5907\u4efd\uff0c\u4e00\u5957\u6545\u969c\u53e6\u4e00\u5957\u4ecd\u53ef\u4fdd\u969c\u57fa\u7840\u751f\u6d3b\uff08\u9a8c\u8bc1\uff1a\u53cc\u4e3b\u673a\u72ec\u7acb\u4f9b\u7535\u72ec\u7acb\u63a7\u5236\uff09\u3002<\/span><\/li>\n          <li><b><span>\u957f\u671f\u7701\u5fc3<\/span>\uff1a<\/b><span>\u62c5\u5fc3\"\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77\"\u3002\u6309\u9700\u5f00\u542f\u65e0\u65e0\u6548\u80fd\u8017\uff0c\u4f4e\u9891\u9ad8\u6548\u8fd0\u884c\uff0c\u914d\u5408\u5ef6\u4fdd\u644a\u8584\u957f\u671f\u4f7f\u7528\u6210\u672c\uff08\u9a8c\u8bc1\uff1a\u65e5\u7acb\u6da1\u65cb\u538b\u7f29\u673a+10\u5e74\u80fd\u6e90\u4fdd\u969c\uff09\u3002<\/span><\/li>\n        <\/ol>\n        <div class=\"lm-flip-hint\">\u70b9\u51fb\u7ffb\u8f6c \u2192 \u8fd4\u56de\u6848\u4f8b\u4fe1\u606f\u5361<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n  <div class=\"lm-hl\"><b>\u7cfb\u7edf\u5b9a\u4f4d\uff1a<\/b>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u67b6\u6784\u2014\u2014\u7cfb\u7edf\u4e00\uff08RAS-125HRNAQ\uff09\u8986\u76d6\u4e00\u697c\u3001\u7cfb\u7edf\u4e8c\uff08RAS-140HRNAQ\uff09\u8986\u76d6\u4e8c\/\u4e09\u697c\uff0c6\u53f0\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u5168\u90e8\u4f4e\u566a\u97f3\u578b\u53f7\u3002\u5916\u673a\u96c6\u4e2d\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u7cbe\u51c6\u5339\u914d\"\u4e0d\u540c\u65f6\u5f00\"\u7684\u751f\u6d3b\u8282\u594f\u3002<\/div>\n  <div class=\"lm-chart-box\" role=\"img\" aria-label=\"\u4e24\u5957\u7cfb\u7edf\u5236\u51b7\u80fd\u529b\u5206\u914d\">\n    <div class=\"lm-chart-title\">\u4e24\u5957\u7cfb\u7edf\u5236\u51b7\u80fd\u529b\u5206\u914d\uff08kW\uff09<\/div>\n    <div class=\"lm-chart-canvas\" id=\"c_bar_sys\"><\/div>\n    <div class=\"lm-chart-cap\">\u672c\u6848\u4f8b\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff1a\u7cfb\u7edf\u4e00\uff08\u4e00\u697cRAS-125HRNAQ\uff09\u5e262\u53f0RPIZ-63\u517112.6kW\uff1b\u7cfb\u7edf\u4e8c\uff08\u4e8c\/\u4e09\u697cRAS-140HRNAQ\uff09\u5e264\u53f0RPIZ\uff0863\/36\/22\/32\uff09\u517115.3kW\uff1b\u5408\u8ba1\u7ea627.9kW\u5236\u51b7\u80fd\u529b\u8986\u76d6\u5168\u5c4b\u7ea6150\u33a1\u7a7a\u8c03\u533a\u57df\u3002<\/div>\n    <noscript><div class=\"lm-chart-fallback\">\u56fe\u8868\u9700\u542f\u7528 JavaScript \u67e5\u770b\u3002\u4e24\u5957\u7cfb\u7edf\u5236\u51b7\u80fd\u529b\u5206\u914d\uff08kW\uff09\uff1a<b>\u7cfb\u7edf\u4e00\u00b7\u4e00\u697c 12.6<\/b>\u3000<b>\u7cfb\u7edf\u4e8c\u00b7\u4e8c\/\u4e09\u697c 15.3<\/b>\u3000\u5408\u8ba1 \u2248 <b>27.9<\/b>\uff1b\u8986\u76d6\u5168\u5c4b\u7ea6150\u33a1\u7a7a\u8c03\u533a\u57df\u3002<\/div><\/noscript>\n  <\/div>\n<script>\n(function(){\n  var c=echarts.init(document.getElementById('c_bar_sys'));\n  c.setOption({\n    tooltip:{trigger:'axis'},\n    grid:{left:80,right:20,top:30,bottom:60},\n    xAxis:{type:'category',data:['\u7cfb\u7edf\u4e00\u00b7\u4e00\u697c','\u7cfb\u7edf\u4e8c\u00b7\u4e8c\/\u4e09\u697c'],axisLabel:{interval:0,fontSize:11}},\n    yAxis:{type:'value',name:'kW'},\n    series:[{type:'bar',data:[12.6,15.3],itemStyle:{color:'#3a2c20'},\n      label:{show:true,position:'top',formatter:'{c} kW'},\n      markLine:{silent:true,symbol:'none',data:[{yAxis:27.9,name:'\u5408\u8ba1'}],lineStyle:{color:'#c9a878'},label:{formatter:'\u5408\u8ba1\u224827.9'}}}]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n<\/script>\n<\/section>\n\n<!-- ===== S2 \u00b7 \u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad\u5206\u6790 ===== -->\n<section class=\"lm-section\" id=\"s2\">\n  <h2>S2 \u00b7 \u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad\u5206\u6790<\/h2>\n  <div class=\"lm-slider\">\n    <div class=\"lm-section-tabs\">\n      <button type=\"button\" class=\"lm-section-tab lm-active\" data-card=\"0\">\u539f\u59cb\u9700\u6c42<\/button>\n      <button type=\"button\" class=\"lm-section-tab\" data-card=\"1\">\u623f\u5c4b\u7279\u6b8a\u6761\u4ef6<\/button>\n      <button type=\"button\" class=\"lm-section-tab\" data-card=\"2\">\u566a\u97f3\u654f\u611f\u6027<\/button>\n    <\/div>\n    <div class=\"lm-content-card lm-active\" data-card=\"0\">\n      <div class=\"lm-card-title\">\u5ba2\u6237\u539f\u59cb\u9700\u6c42<\/div>\n      <table><tr><th>\u9700\u6c42<\/th><th>\u5177\u4f53\u63cf\u8ff0<\/th><\/tr>\n        <tr><td>\u590f\u5929\u5236\u51b7<\/td><td>\u4e09\u5c42\u5168\u5c4b\u5236\u51b7\uff0c\u5236\u51b7\u4e3a\u4e3b\uff0c\u8981\u6c42\u8986\u76d6\u5ba2\u9910\u5385\u3001\u8336\u5ba4\u4e0e\u5404\u5367\u5ba4<\/td><\/tr>\n        <tr><td>\u4f7f\u7528\u4e60\u60ef\uff08\u5173\u952e\uff09<\/td><td>\u4e00\u697c\u548c\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\uff0c\u767d\u5929\u6d3b\u52a8\u96c6\u4e2d\u5728\u4e00\u697c<\/td><\/tr>\n        <tr><td>\u566a\u97f3\u63a7\u5236<\/td><td>\u566a\u97f3\u654f\u611f\uff0c\u6015\u5f71\u54cd\u7761\u7720\uff0c\u5bf9\u8bbe\u5907\u8fd0\u884c\u58f0\u97f3\u8981\u6c42\u9ad8<\/td><\/tr>\n        <tr><td>\u80fd\u8017\u62c5\u5fe7<\/td><td>\u62c5\u5fc3\"\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77\"\uff0c\u5e0c\u671b\u7cfb\u7edf\u771f\u6b63\u7701\u80fd<\/td><\/tr><\/table>\n    <\/div>\n    <div class=\"lm-content-card\" data-card=\"1\">\n      <div class=\"lm-card-title\">\u4e09\u5c42\u8054\u6392\u522b\u5885\u7684\u7279\u6b8a\u6027<\/div>\n      <table><tr><th>\u5f71\u54cd\u56e0\u7d20<\/th><th>\u5bf9\u7a7a\u8c03\u7684\u5f71\u54cd<\/th><th>\u6211\u4eec\u7684\u5e94\u5bf9<\/th><\/tr>\n        <tr><td>\u4e09\u5c42\u9876\u5c42\u5236\u51b7\u8d1f\u8377\u9ad8<\/td><td>\u4e09\u697c\u4e3b\u5367\u53d7\u5c4b\u9876\u8f90\u5c04\u70ed\u5f71\u54cd\uff0c\u5236\u51b7\u8d1f\u8377\u9ad8\u4e8e\u697c\u4e0b<\/td><td>\u4e09\u697c\u4e3b\u5367\u914d\u7f6e205W\/\u33a1\uff0c\u6bd4\u5e38\u89c4\u623f\u95f4\u9ad8\u51fa\u7ea610%<\/td><\/tr>\n        <tr><td>\u4e00\u5c42\u4e8c\u5c42\u4e0d\u540c\u65f6\u4f7f\u7528<\/td><td>\u82e5\u7528\u4e00\u5957\u5927\u5916\u673a\u5e26\u5168\u697c\uff0c\u767d\u5929\u53ea\u5f00\u4e00\u697c\u4f1a\u51fa\u73b0\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"<\/td><td>\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff0c\u6309\u697c\u5c42\u5206\u7ec4<\/td><\/tr>\n        <tr><td>\u697c\u9876\u5916\u673a\u4f4d<\/td><td>\u9ad8\u5c42\u5916\u673a\u4f4d\u901a\u98ce\u6563\u70ed\u597d\uff0c\u4f46\u9700\u6ce8\u610f\u51cf\u9707<\/td><td>\u4f4d\u7f6e\u6781\u4f73\uff0c\u4e13\u4e1a\u51cf\u9707\u57ab\u5b89\u88c5<\/td><\/tr><\/table>\n      <div class=\"lm-hl\"><b>\u987e\u95ee\u8bca\u65ad\uff1a<\/b>\u4e09\u5c42\u522b\u5885\u4e0d\u80fd\u6309\u666e\u901a\u5e73\u5c42\u914d\u7f6e\uff0c\u9700\u8981\u6309\u4f7f\u7528\u4e60\u60ef\u5206\u533a\u8bbe\u8ba1\u3001\u9876\u5c42\u51b7\u91cf\u52a0\u7801\u3001\u566a\u97f3\u6e90\u5934\u8fdc\u79bb\u5367\u5ba4\uff0c\u672c\u65b9\u6848\u5df2\u5168\u90e8\u4f53\u73b0\u3002<\/div>\n    <\/div>\n    <div class=\"lm-content-card\" data-card=\"2\">\n      <div class=\"lm-card-title\">\u566a\u97f3\u654f\u611f\u6027\u5206\u6790<\/div>\n      <table><tr><th>\u566a\u97f3\u6e90\u5934<\/th><th>\u7279\u70b9<\/th><th>\u5e94\u5bf9\u63aa\u65bd<\/th><\/tr>\n        <tr><td>\u5916\u673a\u566a\u97f3<\/td><td>\u4e24\u53f0\u5916\u673a\u8fd0\u884c\u65f6\u7ea654dB<\/td><td>\u5916\u673a\u96c6\u4e2d\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\uff0c\u8fdc\u79bb\u5367\u5ba4\u533a\u57df<\/td><\/tr>\n        <tr><td>\u5185\u673a\u566a\u97f3<\/td><td>\u5367\u5ba4\u9700\u5b89\u9759<\/td><td>\u9009\u7528\u8212\u4eab\u7cfb\u5217\u6700\u4f4e17dB\u9759\u97f3\u5185\u673a<\/td><\/tr><\/table>\n      <div class=\"lm-hl\"><b>\u5bf9\u60a8\u7684\u5f71\u54cd\uff1a<\/b>\u566a\u97f3\u6e90\u5934\uff08\u5916\u673a\uff09\u4e0e\u4f11\u606f\u533a\uff08\u5367\u5ba4\uff09\u5b8c\u5168\u5206\u79bb\uff0c\u5185\u673a\u566a\u97f3\u4ec5\u4e3a 17dB\uff08\u76f8\u5f53\u4e8e\u6811\u53f6\u6c99\u6c99\u58f0\uff09\uff0c\u6ee1\u8db3\u566a\u97f3\u654f\u611f\u9700\u6c42\u3002<\/div>\n    <\/div>\n  <\/div>\n  <div class=\"lm-hl\"><b>\u987e\u95ee\u8bca\u65ad\uff1a<\/b>\u5f20\u5148\u751f\u7684\u6838\u5fc3\u9700\u6c42\u662f\"\u4e09\u5c42\u8054\u6392\u522b\u5885\u3001\u590f\u5929\u5168\u5c4b\u5236\u51b7\u3001\u566a\u97f3\u654f\u611f\u3001\u4e00\u697c\u4e0e\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\u3001\u62c5\u5fc3\u80fd\u8017\"\u3002\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\uff0c\u914d\u5408\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u67b6\u6784\u3001\u8212\u4eab17dB\u9759\u97f3\u5185\u673a\u3001\u5916\u673a\u96c6\u4e2d\u697c\u9876\uff0c\u662f\u5339\u914d\u8be5\u6237\u578b\u4e0e\u4f7f\u7528\u4e60\u60ef\u7684\u65b9\u6848\u3002<\/div>\n<\/section>\n\n<!-- ===== S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e ===== -->\n<section class=\"lm-section\" id=\"s3\">\n  <h2>S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e<\/h2>\n\n  <div class=\"lm-slider\">\n    <div class=\"lm-section-tabs\">\n      <button type=\"button\" class=\"lm-section-tab lm-active\" data-card=\"0\">\u65b9\u6848\u6838\u5fc3<\/button>\n      <button type=\"button\" class=\"lm-section-tab\" data-card=\"1\">\u53cc\u7cfb\u7edf\u5bf9\u6bd4<\/button>\n      <button type=\"button\" class=\"lm-section-tab\" data-card=\"2\">\u6295\u5165\u6784\u6210<\/button>\n    <\/div>\n\n    <div class=\"lm-content-card lm-active\" data-card=\"0\">\n      <div class=\"lm-card-title\">\u89e3\u51b3\u65b9\u6848\u6838\u5fc3\u8981\u70b9<\/div>\n      <table><tr><th>\u8981\u70b9<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u7cfb\u7edf\u4e00\uff08\u4e00\u697c\uff09<\/td><td>\u5916\u673a RAS-125HRNAQ\uff0812.5kW\uff09\u5e262\u53f0 RPIZ-63\uff0c\u8d85\u914d\u7387 101%<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u4e8c\uff08\u4e8c+\u4e09\u697c\uff09<\/td><td>\u5916\u673a RAS-140HRNAQ\uff0814.0kW\uff09\u5e264\u53f0\u5185\u673a\uff0c\u8d85\u914d\u7387 109%<\/td><\/tr>\n        <tr><td>6\u53f0\u5185\u673a\u5168\u4f4e\u566a<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\uff0c\u6700\u4f4e 17dB\uff0c6\u4e2a WiFi \u7ebf\u63a7\u5668\u72ec\u7acb\u63a7\u5236<\/td><\/tr>\n        <tr><td>\u5916\u673a\u96c6\u4e2d\u697c\u9876<\/td><td>\u4e24\u53f0\u5916\u673a\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\uff0c\u901a\u98ce\u6563\u70ed\u597d\u3001\u8ddd\u5367\u5ba4\u6700\u8fdc<\/td><\/tr><\/table>\n      <div class=\"lm-img-gallery\">\n        <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-spec-01.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u914d\u7f6e\u89c4\u683c\u793a\u610f\" loading=\"lazy\"><\/div><figcaption>\u914d\u7f6e\u89c4\u683c\u793a\u610f<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-content-card\" data-card=\"1\">\n      <div class=\"lm-card-title\">\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf vs \u4e00\u5957\u5927\u7cfb\u7edf<\/div>\n      <table><tr><th>\u5bf9\u6bd4\u9879<\/th><th>\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff08\u672c\u65b9\u6848\uff09<\/th><th>\u4e00\u5957\u5927\u7cfb\u7edf<\/th><\/tr>\n        <tr><td>\u6309\u9700\u8282\u80fd<\/td><td>\u2705 \u767d\u5929\u4ec5\u8fd0\u884c\u4e00\u697c\u5916\u673a<\/td><td>\u26a0\ufe0f \u767d\u5929\u5168\u697c\u4ec5\u5f00\u5ba2\u5385\uff0c\u5927\u9a6c\u62c9\u5c0f\u8f66<\/td><\/tr>\n        <tr><td>\u566a\u97f3\u63a7\u5236<\/td><td>\u2705 \u5916\u673a\u6309\u9700\u542f\u505c\uff0c\u566a\u97f3\u6e90\u5c11<\/td><td>\u26a0\ufe0f \u5355\u53f0\u5927\u5916\u673a\u6301\u7eed\u8fd0\u884c<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u5197\u4f59<\/td><td>\u2705 \u4e00\u5957\u6545\u969c\u53e6\u4e00\u5957\u53ef\u5907\u7528<\/td><td>\u26a0\ufe0f \u6545\u969c\u5219\u5168\u5c4b\u65e0\u7a7a\u8c03<\/td><\/tr>\n        <tr><td>\u4f7f\u7528\u5bff\u547d<\/td><td>\u2705 \u542f\u505c\u9891\u7387\u4f4e\uff0c\u5bff\u547d\u66f4\u957f<\/td><td>\u26a0\ufe0f \u9891\u7e41\u4f4e\u8d1f\u8377\u542f\u505c\uff0c\u5bff\u547d\u7f29\u77ed<\/td><\/tr>\n        <tr><td>\u521d\u6295\u8d44<\/td><td>\u26a0\ufe0f \u4e24\u53f0\u5916\u673a\u6210\u672c\u7565\u9ad8<\/td><td>\u2705 \u5355\u53f0\u5916\u673a\u6210\u672c\u7565\u4f4e<\/td><\/tr><\/table>\n      <div class=\"lm-hl\"><b>\u7ed3\u8bba\uff1a<\/b>\u53cc\u536b+\u522b\u5885\u4e09\u5c42+\u4e0d\u540c\u65f6\u5f00+\u566a\u97f3\u654f\u611f\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u662f\u66f4\u4f18\u9009\u62e9\u2014\u2014\u7cbe\u51c6\u5339\u914d\u751f\u6d3b\u8282\u594f\uff0c\u767d\u5929\u5ba2\u5385\u4e00\u5957\u3001\u665a\u4e0a\u5367\u5ba4\u4e00\u5957\uff0c\u4e0d\u6d6a\u8d39\u4e00\u5ea6\u7535\u3002<\/div>\n    <\/div>\n\n    <div class=\"lm-content-card\" data-card=\"2\">\n      <div class=\"lm-card-title\">\u6574\u4f53\u6295\u5165\u6784\u6210<\/div>\n      <p>\u672c\u6848\u4f8b\u6574\u5957\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\uff08\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff0c\u542b\u5916\u673a\u30016\u53f0\u5185\u673a\u30016\u4e2aWiFi\u7ebf\u63a7\u5668\u53ca\u5b89\u88c5\u8f85\u6750\u4eba\u5de5\uff09\u6574\u4f53\u6295\u5165\u5904\u4e8e\u540c\u7c7b\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u7684\u5e38\u89c4\u533a\u95f4\uff0c\u4e3b\u8981\u7531\u8bbe\u5907\u8d39\u3001\u7ebf\u63a7\u5668\u4e0e\u5b89\u88c5\u8f85\u6750\u4eba\u5de5\u4e09\u90e8\u5206\u6784\u6210\u3002\u4e3a\u4fdd\u62a4\u5ba2\u6237\u9690\u79c1\uff0c\u672c\u6848\u4f8b\u4e0d\u62ab\u9732\u5177\u4f53\u91d1\u989d\uff0c\u5b9e\u9645\u4ee5\u73b0\u573a\u52d8\u6d4b\u786e\u8ba4\u540e\u7684\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\uff0c\u4ef7\u683c\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a2026\u5e74V5.0\u4ef7\u683c\u6307\u4ee4\u5e93\u3002<\/p>\n      <div class=\"lm-note\">\ud83d\udccc \u6574\u4f53\u6295\u5165\u7531\u8bbe\u5907\u3001\u7ebf\u63a7\u5668\u3001\u5b89\u88c5\u8f85\u6750\u4eba\u5de5\u6784\u6210\uff0c\u5177\u4f53\u5360\u6bd4\u968f\u6237\u578b\u4e0e\u914d\u7f6e\u6d6e\u52a8\u3002\u62a5\u4ef7\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e0e\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\uff0c\u4ef7\u683c\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a2026\u5e74V5.0\u4ef7\u683c\u6307\u4ee4\u5e93\uff08https:\/\/longmai-nt.com\/?page_id=662\uff09\u3002<br>\ud83d\udd39 \u5b89\u88c5\u8d39\u6309\u522b\u5885\u6807\u51c6\u8ba1\u53d6\uff0c\u542b\u8bbe\u5907\u540a\u88c5\u3001\u94dc\u7ba1\u4fdd\u6e29\u3001\u6392\u6c34\u3001\u5899\u4f53\u5f00\u5b54\u3001\u7ebf\u63a7\u5668\u5b89\u88c5\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u3002<\/div>\n      <div class=\"lm-img-gallery\">\n        <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-quote-02.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u914d\u7f6e\u62a5\u4ef7\u793a\u610f\" loading=\"lazy\"><\/div><figcaption>\u914d\u7f6e\u62a5\u4ef7\u793a\u610f<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s3-1\">\u7cfb\u7edf\u4e00 \u00b7 \u4e00\u697c\uff08RAS-125HRNAQ + 2\u53f0RPIZ-63\uff09<\/h3>\n  <table><tr><th>\u7c7b\u522b<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5bb9\u91cf\/\u53c2\u6570<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u4e3b\u673a<\/td><td>\u65e5\u7acb\u8212\u4eab<\/td><td>RAS-125HRNAQ<\/td><td>1\u53f0<\/td><td>12.5kW \u00b7 APF 5.8 \u00b7 \u566a\u97f354dB<\/td><\/tr>\n    <tr><td>\u5185\u673a1<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a<\/td><td>RPIZ-63FSNAQD\/P<\/td><td>1\u53f0<\/td><td>6.3kW \u00b7 \u6700\u4f4e17dB<\/td><\/tr>\n    <tr><td>\u5185\u673a2<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a<\/td><td>RPIZ-63FSNAQD\/P<\/td><td>1\u53f0<\/td><td>6.3kW \u00b7 \u6700\u4f4e17dB<\/td><\/tr><\/table>\n\n  <h3 id=\"s3-2\">\u7cfb\u7edf\u4e8c \u00b7 \u4e8c\/\u4e09\u697c\uff08RAS-140HRNAQ + 4\u53f0RPIZ\uff09<\/h3>\n  <table><tr><th>\u7c7b\u522b<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5bb9\u91cf\/\u53c2\u6570<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u4e3b\u673a<\/td><td>\u65e5\u7acb\u8212\u4eab<\/td><td>RAS-140HRNAQ<\/td><td>1\u53f0<\/td><td>14.0kW \u00b7 APF 5.5 \u00b7 \u566a\u97f354dB<\/td><\/tr>\n    <tr><td>\u5185\u673a1\uff08\u4e8c\u697c\u4e3b\u5367\uff09<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a<\/td><td>RPIZ-63FSNAQD\/P<\/td><td>1\u53f0<\/td><td>6.3kW \u00b7 \u6700\u4f4e17dB<\/td><\/tr>\n    <tr><td>\u5185\u673a2\uff08\u4e8c\u697c\u513f\u7ae5\u623f\uff09<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a<\/td><td>RPIZ-36FSNAQD\/P<\/td><td>1\u53f0<\/td><td>3.6kW \u00b7 \u6700\u4f4e17dB<\/td><\/tr>\n    <tr><td>\u5185\u673a3\uff08\u4e8c\u697c\u6b21\u5367\uff09<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1\u53f0<\/td><td>2.2kW \u00b7 \u6700\u4f4e17dB<\/td><\/tr>\n    <tr><td>\u5185\u673a4\uff08\u4e09\u697c\u4e3b\u5367\u00b7\u9876\u5c42\uff09<\/td><td>\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1\u53f0<\/td><td>3.2kW \u00b7 \u6700\u4f4e17dB<\/td><\/tr><\/table>\n  <div class=\"lm-hl\"><b>\u8bbe\u8ba1\u4f9d\u636e\uff08\u56fd\u6807\u5408\u89c4\uff09\uff1a<\/b>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB 50736-2012\u3001\u300a\u591a\u8054\u5f0f\u7a7a\u8c03\uff08\u70ed\u6cf5\uff09\u673a\u7ec4\u80fd\u6548\u6807\u51c6\u300bGB 21454-2021\u3001\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u6280\u672f\u624b\u518c\u3002\u51b7\u8d1f\u8377\u6309\u623f\u95f4\u529f\u80fd\u4e0e\u671d\u5411\u53d6\u503c\uff0c\u4e09\u697c\u9876\u5c42\u9002\u5ea6\u52a0\u7801\uff08205W\/\u33a1\uff09\u3002<\/div>\n<\/section>\n\n<!-- ===== S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c ===== -->\n<section class=\"lm-section\" id=\"s4\">\n  <h2>S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c<\/h2>\n\n  <div class=\"lm-hl\"><b>\u7cbe\u5de5\u516d\u6b65\u6cd5 + 2<\/b>\uff5c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u5b89\u88c5\u6d41\u7a0b \u00b7 \u5168\u7a0b\u53ef\u89c6 \u00b7 \u4e09\u65b9\u9a8c\u6536 \u00b7 \u6863\u6848\u53ef\u8ffd\u6eaf<\/div>\n\n  <h3 id=\"s4-1\">\u2463 \u4e13\u4e1a\u65b9\u6848\u8bbe\u8ba1 \u00b7 \u73b0\u573a\u52d8\u6d4b<\/h3>\n  <p>\u9f99\u8109\u6696\u901a\u4e3a\u5f20\u5148\u751f\u51fa\u5177\u4e13\u5c5e\u7a7a\u8c03\u5e73\u9762\u5e03\u7f6e\u56fe\uff0c\u7cbe\u786e\u6807\u6ce8\u5185\u673a\u4f4d\u7f6e\u3001\u7ba1\u8def\u8d70\u5411\u3001\u697c\u9876\u5916\u673a\u5e03\u7f6e\u4e0e\u98ce\u53e3\u5c3a\u5bf8\uff0c\u5e76\u73b0\u573a\u52d8\u6d4b\u697c\u9876\u5916\u673a\u4f4d\u7cbe\u786e\u5c3a\u5bf8\u4e0e\u7ba1\u8def\u8d70\u5411\u3002<\/p>\n  <div class=\"lm-img-gallery\">\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-survey-corridor-01.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u73b0\u573a\u52d8\u6d4b\u8d70\u9053\" loading=\"lazy\"><\/div><figcaption>\u73b0\u573a\u52d8\u6d4b\u8d70\u9053<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-survey-measurement-02.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u73b0\u573a\u6d4b\u91cf\" loading=\"lazy\"><\/div><figcaption>\u73b0\u573a\u6d4b\u91cf<\/figcaption><\/figure>\n  <\/div>\n\n  <h3 id=\"s4-2\">\u2464 \u5185\u673a\u540a\u88c5 \u00b7 \u5916\u673a\u5c31\u4f4d \u00b7 \u94dc\u7ba1\u5b89\u88c5<\/h3>\n  <p>6\u53f0\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u9690\u853d\u540a\u88c5\uff0c\u4e24\u53f0\u5916\u673a\u96c6\u4e2d\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\u5e76\u52a0\u88c5\u4e13\u4e1a\u51cf\u9707\u57ab\uff1b\u94dc\u7ba1\u710a\u63a5\u4e25\u683c\u6267\u884c\u6c2e\u6c14\u4fdd\u62a4\u710a\uff0c\u675c\u7edd\u5185\u58c1\u6c27\u5316\u4ea7\u751f\u710a\u6e23\uff1bR410A\u7cfb\u7edf\u4fdd\u538b\u68c0\u6d4b\u6c14\u5bc6\u6027\u3002\u4ee5\u4e0b\u4e3a\u9f99\u8109\u7cbe\u5de5\u5b89\u88c5\u6807\u51c6\u793a\u610f\uff1a<\/p>\n  <div class=\"lm-img-gallery\">\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u5185\u673a\u540a\u88c5\" loading=\"lazy\"><\/div><figcaption>\u5185\u673a\u540a\u88c5<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd2.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u5185\u673a\u540a\u88c5\u7ec6\u8282\" loading=\"lazy\"><\/div><figcaption>\u5185\u673a\u540a\u88c5\u7ec6\u8282<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u5185\u673a\u9690\u853d\u5b89\u88c5\" loading=\"lazy\"><\/div><figcaption>\u5185\u673a\u9690\u853d\u5b89\u88c5<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz2.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u5185\u673a\u5b89\u88c5\u5b9e\u666f\" loading=\"lazy\"><\/div><figcaption>\u5185\u673a\u5b89\u88c5\u5b9e\u666f<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz3.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u5185\u673a\u5b89\u88c5\" loading=\"lazy\"><\/div><figcaption>\u5185\u673a\u5b89\u88c5<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-fdaz.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u5916\u673a\u5c31\u4f4d\u5b89\u88c5\" loading=\"lazy\"><\/div><figcaption>\u5916\u673a\u5c31\u4f4d<\/figcaption><\/figure>\n  <\/div>\n\n  <h3 id=\"s4-3\">\u2465 \u7cfb\u7edf\u8c03\u8bd5 \u00b7 \u62bd\u771f\u7a7a\u4e0e\u4ea4\u4ed8\u6559\u5b66<\/h3>\n  <p>\u771f\u7a7a\u5e72\u71e5\u540e\u8ffd\u52a0\u51b7\u5a92\uff0c\u5404\u6a21\u5f0f\u8054\u52a8\u6d4b\u8bd5\uff1b\u73b0\u573a\u6559\u5b66WiFi\u7ebf\u63a7\u5668\u64cd\u4f5c\u3001\u5206\u533a\u72ec\u7acb\u63a7\u6e29\u4e0eAPP\u8fdc\u7a0b\u63a7\u5236\u3002\u5730\u6696\u9700\u6c42\u5f85\u5ba2\u6237\u786e\u8ba4\uff0c\u5982\u540e\u671f\u52a0\u88c5\u53ef\u57fa\u4e8e\u73b0\u6709\u7cfb\u7edf\u6269\u5c55\u3002<\/p>\n  <div class=\"lm-img-gallery\">\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u62bd\u771f\u7a7a\u4fdd\u538b\" loading=\"lazy\"><\/div><figcaption>\u62bd\u771f\u7a7a\u4fdd\u538b<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-pressure-test-001.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u7cfb\u7edf\u6253\u538b\u6d4b\u8bd5\" loading=\"lazy\"><\/div><figcaption>\u7cfb\u7edf\u6253\u538b\u6d4b\u8bd5\uff08\u4e00\uff09<\/figcaption><\/figure>\n    <figure><div class=\"lm-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-pressure-test-002.jpg\" alt=\"\u73d1\u6a3e\u4e00\u53f7\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u00b7\u7cfb\u7edf\u6253\u538b\u6d4b\u8bd5\" loading=\"lazy\"><\/div><figcaption>\u7cfb\u7edf\u6253\u538b\u6d4b\u8bd5\uff08\u4e8c\uff09<\/figcaption><\/figure>\n  <\/div>\n\n  <h3>\u670d\u52a1\u4fdd\u969c\u4f53\u7cfb<\/h3>\n  <table><tr><th>\u4fdd\u969c\u9879\u76ee<\/th><th>\u5177\u4f53\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u8d28\u4fdd\u627f\u8bfa<\/td><td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd + \u9f99\u8109\u5de5\u7a0b\u8d28\u4fdd<b>5\u5e74\u8d77<\/b>\uff0c\u52a0\u5165\u9f99\u810910\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212B\u7ec4\uff0c\u5ef6\u4fdd\u81f310\u5e74\uff0c\u8fdc\u8d85\u884c\u4e1a3\u5e74\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u540c\u57ce\u54cd\u5e94<\/td><td>\u6210\u90fd\u5168\u57df\u540c\u57ce\u552e\u540e\u54cd\u5e94\uff0c\u73d1\u6a3e\u4e00\u53f7\u533a\u57df\u4f18\u5148\u5b89\u6392<\/td><\/tr>\n    <tr><td>\u6301\u8bc1\u4e0a\u5c97<\/td><td>\u5b89\u88c5\u4eba\u5458\u5168\u90e8\u7ecf\u8fc7\u65e5\u7acb\u6280\u672f\u57f9\u8bad\u8003\u6838\uff0c\u6301\u8bc1\u4e0a\u5c97<\/td><\/tr>\n    <tr><td>\u8fc7\u7a0b\u900f\u660e<\/td><td>\u4ece\u5b9a\u4f4d\u5230\u9a8c\u6536\u5168\u7a0b\u62cd\u7167\u53d1\u5ba2\u6237\u7fa4\uff0c\u5173\u952e\u8282\u70b9\u4e09\u65b9\u7b7e\u5b57<\/td><\/tr>\n    <tr><td>\u5341\u5e74\u80fd\u6e90\u4fdd\u969c<\/td><td>\u4f1a\u5458B\u7ec4\u4eab\u514d\u8d39\u667a\u80fd\u7535\u8868\u300110\u5e74AI\u80fd\u6e90\u7ba1\u5bb6\u3001\u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u3001\u540c\u6237\u578b\u8131\u654f\u5bf9\u6807<\/td><\/tr><\/table>\n<\/section>\n\n<!-- ===== S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3 ===== -->\n<section class=\"lm-section\" id=\"s5\">\n  <h2>S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/h2>\n  <h3 id=\"s5-1\">\u914d\u7f6e\u5408\u7406\u6027\u8bca\u65ad<\/h3>\n  <table><tr><th>\u68c0\u67e5\u9879<\/th><th>\u914d\u7f6e\u503c<\/th><th>\u662f\u5426\u5408\u7406<\/th><th>\u5206\u6790<\/th><\/tr>\n    <tr><td>\u8d85\u914d\u7387\uff08\u7cfb\u7edf\u4e00\u00b7\u4e00\u697c\uff09<\/td><td>\u5185\u673a12.6kW \/ \u5916\u673a12.5kW = 101%<\/td><td>\u2705 \u9ec4\u91d1\u533a\u95f4<\/td><td>\u5916\u673a\u4e0e\u5185\u673a\u7cbe\u51c6\u5339\u914d\uff0c\u8fd0\u884c\u6548\u7387\u6700\u9ad8<\/td><\/tr>\n    <tr><td>\u8d85\u914d\u7387\uff08\u7cfb\u7edf\u4e8c\u00b7\u4e8c\/\u4e09\u697c\uff09<\/td><td>\u5185\u673a15.3kW \/ \u5916\u673a14.0kW = 109%<\/td><td>\u2705 \u5141\u8bb8\u533a\u95f4<\/td><td>\u5367\u5ba4\u533a\u540c\u65f6\u4f7f\u7528\u7387\u4f4e\uff0c\u5408\u7406<\/td><\/tr>\n    <tr><td>\u5ba2\u9910\u5385\u8fde\u901a\u7a7a\u95f4<\/td><td>2\u53f063\u578b\uff0812.6kW\uff09\/ \u7ea668\u33a1<\/td><td>\u2705 \u7ea6185W\/\u33a1<\/td><td>\u4e24\u53f0\u5185\u673a\u5206\u533a\u63a7\u5236\u66f4\u5408\u7406<\/td><\/tr>\n    <tr><td>\u566a\u97f3\u63a7\u5236<\/td><td>\u5185\u673a17dB + \u5916\u673a\u697c\u9876<\/td><td>\u2705 \u6ee1\u8db3\u566a\u97f3\u654f\u611f<\/td><td>\u566a\u97f3\u6e90\u4e0e\u5367\u5ba4\u5b8c\u5168\u5206\u79bb<\/td><\/tr>\n    <tr><td>\u4f7f\u7528\u4e60\u60ef\u5339\u914d<\/td><td>\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf<\/td><td>\u2705 \u5b8c\u7f8e\u5339\u914d\"\u4e0d\u540c\u65f6\u5f00\"<\/td><td>\u767d\u5929\u4e00\u697c\u3001\u665a\u4e0a\u4e8c\u4e09\u697c\uff0c\u65e0\u65e0\u6548\u80fd\u8017<\/td><\/tr>\n    <tr><td>\u5185\u673a\u5197\u4f59<\/td><td>6\u53f0\u5bf9\u5e946\u533a\u57df<\/td><td>\u2705 \u65e0\u5197\u4f59<\/td><td>\u6bcf\u53f0\u72ec\u7acb\u5bf9\u5e94\u4e00\u4e2a\u533a\u57df<\/td><\/tr><\/table>\n  <div class=\"lm-chart-box\" role=\"img\" aria-label=\"\u4e24\u5957\u7cfb\u7edf\u8d85\u914d\u7387\u6838\u7b97\">\n    <div class=\"lm-chart-title\">\u4e24\u5957\u7cfb\u7edf\u8d85\u914d\u7387\u6838\u7b97\uff08%\uff09<\/div>\n    <div class=\"lm-chart-canvas\" id=\"c_bar_super\"><\/div>\n    <div class=\"lm-chart-cap\">\u8d85\u914d\u7387=\u5185\u673a\u603b\u51b7\u91cf\/\u5916\u673a\u51b7\u91cf\u3002\u7cfb\u7edf\u4e00101%\u5904\u4e8e\u9ec4\u91d1\u533a\u95f4\uff0c\u7cfb\u7edf\u4e8c109%\u5904\u4e8e\u5141\u8bb8\u533a\u95f4\uff0c\u4e24\u5957\u7cfb\u7edf\u5747\u7b26\u5408\u8bbe\u8ba1\u89c4\u8303\uff0c\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a\uff1b\u5141\u8bb8\u4e0a\u9650\u2264130%\u3002<\/div>\n    <noscript><div class=\"lm-chart-fallback\">\u56fe\u8868\u9700\u542f\u7528 JavaScript \u67e5\u770b\u3002\u4e24\u5957\u7cfb\u7edf\u8d85\u914d\u7387\u6838\u7b97\uff08%\uff09\uff1a<b>\u7cfb\u7edf\u4e00\u00b7\u4e00\u697c 101%<\/b>\uff08\u9ec4\u91d1\u533a\u95f4\uff09\u3000<b>\u7cfb\u7edf\u4e8c\u00b7\u4e8c\/\u4e09\u697c 109%<\/b>\uff08\u5141\u8bb8\u533a\u95f4\uff09\uff1b\u5141\u8bb8\u4e0a\u9650 \u2264 <b>130%<\/b>\uff0c\u4e24\u5957\u7cfb\u7edf\u5747\u7b26\u5408\u8bbe\u8ba1\u89c4\u8303\u3002<\/div><\/noscript>\n  <\/div>\n<script>\n(function(){\n  var c=echarts.init(document.getElementById('c_bar_super'));\n  c.setOption({\n    tooltip:{trigger:'axis',formatter:'{b}<br\/>\u8d85\u914d\u7387: {c}%'},\n    grid:{left:70,right:20,top:30,bottom:50},\n    xAxis:{type:'category',data:['\u7cfb\u7edf\u4e00\u00b7\u4e00\u697c','\u7cfb\u7edf\u4e8c\u00b7\u4e8c\/\u4e09\u697c'],axisLabel:{interval:0,fontSize:11}},\n    yAxis:{type:'value',name:'%',max:150},\n    series:[{type:'bar',data:[101,109],itemStyle:{color:'#3a2c20'},\n      label:{show:true,position:'top',formatter:'{c}%'},\n      markLine:{silent:true,symbol:'none',data:[{yAxis:130,name:'\u5141\u8bb8\u4e0a\u9650'}],lineStyle:{color:'#c9a878'},label:{formatter:'\u5141\u8bb8\u2264130%'}}}]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n<\/script>\n\n  <h3>\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h3>\n  <table><tr><th>\u7ef4\u5ea6<\/th><th>\u5e02\u573a\u666e\u901a\u65b9\u6848<\/th><th>\u672c\u65b9\u6848<\/th><\/tr>\n    <tr><td>\u6309\u9700\u8282\u80fd<\/td><td>\u2b50\u2b50\u2b50\u2606\u2606<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u672c\u65b9\u6848\uff08\u4e24\u5957\u72ec\u7acb\u6309\u9700\u5f00\u542f\uff09<\/td><\/tr>\n    <tr><td>\u9759\u97f3\u6027<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2606<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u672c\u65b9\u6848\uff08\u5185\u673a17dB+\u5916\u673a\u697c\u9876\uff09<\/td><\/tr>\n    <tr><td>\u6e29\u5ea6\u5747\u5300<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2606<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u672c\u65b9\u6848<\/td><\/tr>\n    <tr><td>\u7cfb\u7edf\u5197\u4f59<\/td><td>\u2b50\u2b50\u2606\u2606\u2606<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u672c\u65b9\u6848\uff08\u4e92\u4e3a\u5907\u4efd\uff09<\/td><\/tr>\n    <tr><td>\u667a\u80fd\u64cd\u4f5c<\/td><td>\u2b50\u2b50\u2b50\u2606\u2606<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u672c\u65b9\u6848\uff08WiFi\u7ebf\u63a7\u5668+APP\uff09<\/td><\/tr>\n    <tr><td>\u957f\u671f\u53ef\u9760<\/td><td>\u2b50\u2b50\u2b50\u2606\u2606<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u672c\u65b9\u6848\uff08\u53cc\u4e3b\u673a+10\u5e74\u4fdd\u969c\uff09<\/td><\/tr><\/table>\n  <div class=\"lm-note\">\ud83d\udccc \u8d39\u7528\u516d\u7ef4\u5ea6\uff08\u5b9a\u6027\uff09\uff1a\u521d\u6295\u8d44\u5904\u540c\u7c7b\u65b9\u6848\u5e38\u89c4\u533a\u95f4\uff08\u4e24\u53f0\u5916\u673a\u6210\u672c\u7565\u9ad8\u4e8e\u5355\u7cfb\u7edf\uff09\uff1b\u7cfb\u7edf\u80fd\u6548\u9ad8\uff08\u6309\u9700\u5f00\u542f\u65e0\u65e0\u6548\u80fd\u8017\uff09\uff1b\u5b89\u88c5\u590d\u6742\u5ea6\u53ef\u63a7\uff08\u5206\u533a\u53cc\u7cfb\u7edf+\u697c\u9876\u5916\u673a\uff09\uff1b\u7cfb\u7edf\u53ef\u9760\u6027\u9ad8\uff08\u4e92\u4e3a\u5907\u4efd\uff09\uff1b\u957f\u671f\u8fd0\u884c\u8d39\u4f4e\uff08\u4f4e\u9891\u9ad8\u6548+\u5ef6\u4fdd\u644a\u8584\uff09\uff1b\u8bbe\u8ba1\u4f7f\u7528\u5bff\u547d15\u5e74\uff08\u52a0\u5165\u9f99\u810910\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212B\u7ec4\uff0c\u5ef6\u4fdd10\u5e74\uff09\u3002<\/div>\n\n  <div class=\"lm-chart-box\" id=\"s5-2\" role=\"img\" aria-label=\"\u516d\u7ef4\u7efc\u5408\u8bc4\u5206\">\n    <div class=\"lm-chart-title\">\u516d\u7ef4\u7efc\u5408\u8bc4\u5206\uff08\u6ee1\u520610\uff09<\/div>\n    <div class=\"lm-chart-canvas\" id=\"c_radar_six\"><\/div>\n    <div class=\"lm-chart-cap\">\u516d\u7ef4\u7efc\u5408\u8bc4\u5206\uff1a\u8282\u80fd(9.2,\u6309\u9700\u5f00\u542f\u65e0\u65e0\u6548\u80fd\u8017)\u3001\u8212\u9002(9.3,17dB\u9759\u97f3+\u5206\u533a\u5747\u5300)\u3001\u7075\u6d3b(9.4,\u4e24\u5957\u72ec\u7acb\u6309\u9700+\u4e92\u4e3a\u5907\u4efd)\u3001\u7a33\u5b9a(9.3,\u65e5\u7acb\u6da1\u65cb\u538b\u7f29\u673a+\u53cc\u7cfb\u7edf\u5197\u4f59)\u3001\u6210\u672c(8.8,\u521d\u6295\u7565\u9ad8\u4f46\u957f\u671f\u7701\u80fd+\u5ef6\u4fdd\u644a\u8584)\u3001\u957f\u671f(9.1,5\u5e74\u8d28\u4fdd+10\u5e74\u80fd\u6e90\u4fdd\u969c+\u54c1\u724c\u53e3\u7891)\u3002<\/div>\n    <noscript><div class=\"lm-chart-fallback\">\u56fe\u8868\u9700\u542f\u7528 JavaScript \u67e5\u770b\u3002\u516d\u7ef4\u7efc\u5408\u8bc4\u5206\uff08\u6ee1\u520610\uff09\uff1a<b>\u8282\u80fd 9.2<\/b>\u3000<b>\u8212\u9002 9.3<\/b>\u3000<b>\u7075\u6d3b 9.4<\/b>\u3000<b>\u7a33\u5b9a 9.3<\/b>\u3000<b>\u6210\u672c 8.8<\/b>\u3000<b>\u957f\u671f 9.1<\/b>\u3002<\/div><\/noscript>\n  <\/div>\n<script>\n(function(){\n  var c=echarts.init(document.getElementById('c_radar_six'));\n  c.setOption({\n    tooltip:{},\n    legend:{data:['\u672c\u6848\u4f8b\u8bc4\u5206']},\n    radar:{indicator:[{name:'\u8282\u80fd',max:10},{name:'\u8212\u9002',max:10},{name:'\u7075\u6d3b',max:10},{name:'\u7a33\u5b9a',max:10},{name:'\u6210\u672c',max:10},{name:'\u957f\u671f',max:10}]},\n    series:[{type:'radar',data:[\n      {value:[9.2,9.3,9.4,9.3,8.8,9.1],name:'\u672c\u6848\u4f8b\u8bc4\u5206',itemStyle:{color:'#3a2c20'},areaStyle:{opacity:0.1}}\n    ]}]\n  });\n  window.addEventListener('resize',function(){c.resize();});\n})();\n<\/script>\n<\/section>\n\n<!-- ===== \u76f8\u5173\u65b9\u6848\u4e0e\u77e5\u8bc6\uff08\u5185\u94fe\uff09 ===== -->\n<section class=\"lm-section\" id=\"links\">\n  <h2>\u76f8\u5173\u65b9\u6848\u4e0e\u77e5\u8bc6<\/h2>\n  <div class=\"lm-links\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\">\n      <div class=\"lm-lt\">\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u6807\u51c6<\/div>\n      <div class=\"lm-ld\">\u9f99\u8109\u6696\u901a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\/\u4e09\u8054\u4f9b\u5b89\u88c5\u65bd\u5de5\u6d41\u7a0b\u4e0e\u9a8c\u6536\u89c4\u8303<\/div>\n    <\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=662\" target=\"_blank\">\n      <div class=\"lm-lt\">\u9f99\u8109\u6696\u901a\u4ea7\u54c1\u4ef7\u683c\u5e93<\/div>\n      <div class=\"lm-ld\">\u65e5\u7acb\u5168\u7cfb\u4ea7\u54c1\u5b8c\u6574\u4ef7\u683c\u8868\uff0c\u542b\u9762\u4ef7\/\u96f6\u552e\u4ef7\/\u5957\u9910\u4ef7\/\u56fd\u8865\u89c4\u5219<\/div>\n    <\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\n      <div class=\"lm-lt\">\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u5e93<\/div>\n      <div class=\"lm-ld\">\u9f99\u8109\u6696\u901a\u5386\u5e74\u771f\u5b9e\u6848\u4f8b\uff0c\u8986\u76d6\u5404\u6237\u578b\u5404\u9762\u79ef\u5404\u7cfb\u7edf\u65b9\u6848<\/div>\n    <\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\n      <div class=\"lm-lt\">\u540c\u533a\u57df\u5bf9\u6807\u6848\u4f8b<\/div>\n      <div class=\"lm-ld\">\u4e09\u5c42\u8054\u6392\u522b\u5885\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u53c2\u8003\u6848\u4f8b<\/div>\n    <\/a>\n  <\/div>\n<\/section>\n\n<!-- ===== \u9ad8\u9891\u95ee\u9898\uff08FAQ\uff09 ===== -->\n<section class=\"lm-section\" id=\"s6\">\n  <h2>\u9ad8\u9891\u95ee\u9898<\/h2>\n  <p style=\"font-size:.88rem;color:#7a6e5c\">\u4e1a\u4e3b\u5728\u505a\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u51b3\u7b56\u65f6\u6700\u5e38\u63d0\u51fa\u7684\u95ee\u9898\uff1a<\/p>\n  <div class=\"lm-faq\">\n    <details>\n      <summary><span>\u4e09\u5c42\u8054\u6392\u522b\u5885\u4e3a\u4ec0\u4e48\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u800c\u4e0d\u662f\u4e00\u5957\u5927\u7cfb\u7edf\uff1f<\/span><\/summary>\n      <div class=\"lm-faq-a\">\u5f20\u5148\u751f\u5bb6\u4e00\u697c\u4e0e\u4e8c\u4e09\u697c\u4e0d\u540c\u65f6\u5f00\uff0c\u82e5\u7528\u4e00\u5957\u5927\u5916\u673a\u5e26\u5168\u697c\uff0c\u767d\u5929\u53ea\u5f00\u4e00\u697c\u4f1a\u51fa\u73b0\u5927\u9a6c\u62c9\u5c0f\u8f66\u3001\u65e0\u6548\u80fd\u8017\u3002\u91c7\u7528\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff08\u4e00\u697c125\u5916\u673a+\u4e8c\u4e09\u697c140\u5916\u673a\uff09\uff0c\u767d\u5929\u5f00\u4e00\u697c\u5c0f\u673a\u3001\u665a\u4e0a\u5f00\u4e8c\u4e09\u697c\u4e2d\u673a\uff0c\u7cbe\u51c6\u5339\u914d\u751f\u6d3b\u8282\u594f\uff0c\u4e14\u4e00\u5957\u6545\u969c\u53e6\u4e00\u5957\u53ef\u5907\u7528\u3002<\/div>\n    <\/details>\n    <details>\n      <summary><span>\u65e5\u7acb\u8212\u4eab\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\u662f\u600e\u4e48\u505a\u5230\u7684\uff1f<\/span><\/summary>\n      <div class=\"lm-faq-a\">\u8212\u4eab\u8584\u578b\u98ce\u7ba1\u673a\u91c7\u7528\u76f4\u6d41\u53d8\u9891\u98ce\u673a\u4e0e\u4f18\u5316\u98ce\u9053\u8bbe\u8ba1\uff0c\u6700\u4f4e\u8fd0\u884c\u566a\u97f317dB\uff08\u76f8\u5f53\u4e8e\u6811\u53f6\u6c99\u6c99\u58f0\uff09\uff0c\u5367\u5ba4\u573a\u666f\u4f18\u5148\u9009\u7528\u4f4e\u566a\u97f3\u578b\u53f7\uff1b\u5916\u673a\u96c6\u4e2d\u7f6e\u4e8e\u697c\u9876\u5e73\u53f0\uff0c\u4e0e\u4f11\u606f\u533a\u5b8c\u5168\u5206\u79bb\uff0c\u53cc\u91cd\u4fdd\u969c\u9759\u97f3\u3002<\/div>\n    <\/details>\n    <details>\n      <summary><span>\u4e24\u5957\u7cfb\u7edf\u4f1a\u4e0d\u4f1a\u6bd4\u4e00\u5957\u66f4\u8d39\u7535\uff1f<\/span><\/summary>\n      <div class=\"lm-faq-a\">\u4e0d\u4f1a\u3002\u6309\u9700\u5f00\u542f\u53cd\u66f4\u7701\u80fd\uff1a\u767d\u5929\u4ec5\u8fd0\u884c\u4e00\u697c\u5916\u673a\uff0c\u4e8c\u4e09\u697c\u7cfb\u7edf\u4f11\u7720\uff0c\u907f\u514d\u5927\u9a6c\u62c9\u5c0f\u8f66\u3002\u4e24\u5957\u7cfb\u7edf\u8d85\u914d\u7387101%\/109%\uff0c\u5747\u5904\u4e8e\u9ad8\u6548\u8fd0\u884c\u533a\u95f4\uff0c\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a\u4e14\u5bff\u547d\u66f4\u957f\u3002<\/div>\n    <\/details>\n    <details>\n      <summary><span>\u697c\u9876\u5916\u673a\u566a\u97f3\u4f1a\u5f71\u54cd\u4f11\u606f\u5417\uff1f<\/span><\/summary>\n      <div class=\"lm-faq-a\">\u697c\u9876\u5e73\u53f0\u901a\u98ce\u6563\u70ed\u597d\u3001\u8ddd\u5367\u5ba4\u6700\u8fdc\uff0c\u5916\u673a\u8fd0\u884c\u566a\u97f3\u7ea654dB\u4e14\u8fdc\u79bb\u4f11\u606f\u533a\uff1b\u5367\u5ba4\u7aef\u753117dB\u5185\u673a\u9001\u98ce\uff0c\u566a\u97f3\u6e90\u5934\u4e0e\u4f11\u606f\u533a\u5b8c\u5168\u5206\u79bb\uff0c\u6ee1\u8db3\u566a\u97f3\u654f\u611f\u9700\u6c42\u3002<\/div>\n    <\/details>\n    <details>\n      <summary><span>\u8d85\u914d\u7387101%\u548c109%\u5408\u4e0d\u5408\u7406\uff1f<\/span><\/summary>\n      <div class=\"lm-faq-a\">\u8d85\u914d\u7387=\u5185\u673a\u603b\u51b7\u91cf\/\u5916\u673a\u51b7\u91cf\u3002\u4e00\u697c101%\u5904\u4e8e\u9ec4\u91d1\u533a\u95f4\u3001\u4e8c\u4e09\u697c109%\u5904\u4e8e\u5141\u8bb8\u533a\u95f4\uff08\u5141\u8bb8\u4e0a\u9650\u2264130%\uff09\uff0c\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a\uff0c\u7b26\u5408\u8bbe\u8ba1\u89c4\u8303\uff0c\u540c\u65f6\u517c\u987e\u4e0d\u540c\u65f6\u5f00\u7684\u4f7f\u7528\u4e60\u60ef\u3002<\/div>\n    <\/details>\n    <details>\n      <summary><span>\u5730\u6696\u8981\u4e0d\u8981\u4e00\u8d77\u505a\uff1f<\/span><\/summary>\n      <div class=\"lm-faq-a\">\u672c\u6848\u4f8b\u4ee5\u4e2d\u592e\u7a7a\u8c03\u4e3a\u4e3b\uff0c\u5730\u6696\u9700\u6c42\u5f85\u4e0e\u5ba2\u6237\u786e\u8ba4\u3002\u5982\u540e\u671f\u52a0\u88c5\uff0c\u9f99\u8109\u53ef\u57fa\u4e8e\u73b0\u6709\u4e24\u5957\u7cfb\u7edf\u7684\u5916\u673a\u9884\u7559\u80fd\u529b\u4e0e\u6c34\u6a21\u5757\u63a5\u53e3\u6269\u5c55\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u65b9\u6848\u4e3a\u51c6\u3002<\/div>\n    <\/details>\n  <\/div>\n<\/section>\n\n<!-- ===== \u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97 ===== -->\n<section class=\"lm-section\" id=\"s7\">\n  <h2>\u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97<\/h2>\n  <p style=\"font-size:.88rem;color:#7a6e5c\">\u9f99\u8109\u6696\u901a\u4e3a\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546\uff0c\u4ee5\u4e0b\u4e3a\u76f8\u5173\u6388\u6743\u8bc1\u4e66\uff1a<\/p>\n  <div class=\"lm-cert-grid\">\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u00b7\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u00b7\u91d1\u724c\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u00b7\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500 2026<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u6c34\u5885\u9002\u00b7\u5929\u6c1f\u5730\u6c34\u7279\u7ea6\u7ecf\u9500\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500<\/figcaption>\n    <\/figure>\n  <\/div>\n  <p style=\"font-size:.88rem;color:#7a6e5c;margin-top:16px\">\u65b9\u6848\u54a8\u8be2\u4e0e\u8bbe\u5907\u9a8c\u6536\u53ef\u81f3\u9f99\u8109\u6696\u901a\u95e8\u5e97\uff1a<\/p>\n  <div class=\"lm-store-grid\">\n    <figure>\n      <div class=\"lm-store-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u5e97\u00b7\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\n        <div class=\"lm-store-name\">\u5357\u5bcc\u68ee\u5e97<\/div>\n        <div class=\"lm-addr\">\ud83d\udccd \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/div>\n        <div class=\"lm-addr\">\ud83d\udcde 028-86131795<\/div>\n      <\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-store-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u5e97\u00b7\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\n        <div class=\"lm-store-name\">\u5317\u5bcc\u68ee\u5e97<\/div>\n        <div class=\"lm-addr\">\ud83d\udccd \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/div>\n        <div class=\"lm-addr\">\ud83d\udcde 028-65272586<\/div>\n      <\/figcaption>\n    <\/figure>\n  <\/div>\n<\/section>\n\n<div style=\"display:none\">\u73d1\u6a3e\u4e00\u53f7 \u5f20\u5148\u751f \u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03 \u8054\u6392\u522b\u5885 \u4e09\u5c42 \u4e24\u5957\u72ec\u7acb\u7cfb\u7edf \u53cc\u7cfb\u7edf \u6309\u9700\u8282\u80fd 17dB\u9759\u97f3 \u8d85\u914d\u7387101% \u8d85\u914d\u7387109% \u5916\u673a\u697c\u9876 RAS-125HRNAQ RAS-140HRNAQ \u9f99\u8109\u6696\u901a \u6210\u90fd\u6696\u901a \u7cbe\u5de5\u516d\u6b65\u6cd5<\/div>\n<!-- ===== \u6848\u4f8b\u5143\u4fe1\u606f \u00b7 \u670d\u52a1\u8986\u76d6 \u00b7 \u56de\u6d41\u5185\u94fe ===== -->\n<div class=\"lm-backflow\" aria-label=\"\u6848\u4f8b\u5143\u4fe1\u606f\u4e0e\u76f8\u5173\u6848\u4f8b\">\n  <div class=\"lm-bf-title\">\ud83d\udcce \u66f4\u591a\u6210\u90fd\u6696\u901a\u5b8c\u5de5\u6848\u4f8b\u53c2\u8003<\/div>\n  <div>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u6210\u90fd\u5168\u5e02\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b\u805a\u5408\u9875<\/a> \u00b7\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=5849\">\u6210\u90fd109\u5957\u6237\u578b\u65b9\u6848\u5e93<\/a> \u00b7\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\">\u6210\u90fd\u5730\u6696\u7cfb\u7edf\u4e13\u9879\u6848\u4f8b<\/a> \u00b7\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=3147\">\u6bcf\u65e5\u65b0\u6848\u4f8b\u65e5\u66f4\u805a\u5408<\/a> \u00b7\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=3023\">\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/a>\n  <\/div>\n  <div class=\"lm-meta\">\n    \ud83d\uddfa\ufe0f <b>\u670d\u52a1\u8986\u76d6<\/b>\uff1a\u6210\u90fd\u5168\u57df\uff08\u6b66\u4faf\u00b7\u9526\u6c5f\u00b7\u9752\u7f8a\u00b7\u91d1\u725b\u00b7\u6210\u534e\u00b7\u9ad8\u65b0\u00b7\u5929\u5e9c\u00b7\u53cc\u6d41\u00b7\u9f99\u6cc9\u00b7\u90eb\u90fd\u00b7\u6e29\u6c5f\u00b7\u65b0\u90fd\u00b7\u9752\u767d\u6c5f\uff09<br>\n    \ud83d\udd50 <b>\u66f4\u65b0\u65e5\u671f<\/b>\uff1a2026\u5e747\u6708<br>\n    \ud83c\udd93 <b>\u514d\u8d39\u670d\u52a1<\/b>\uff1a\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b + \u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\n  <\/div>\n<\/div>\n\n<div class=\"lm-foot\">\n  <div style=\"margin-bottom:6px\"><b>\u65b9\u6848\u987e\u95ee<\/b>\uff1a\u9ec4\u52c7 \u00b7 15828489188\u3000|\u3000\u6df1\u8015\u6210\u90fd\u6696\u901a\u7cfb\u7edf\uff0c\u7cbe\u901a\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u96c6\u6210<\/div>\n  <div>\u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6848\u4f8b\uff08\u73d1\u6a3e\u4e00\u53f7\u5f20\u5148\u751f\u00b7\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\uff09\u3002\u672c\u6848\u4f8b\u6570\u636e\u7ecf\u8131\u654f\u5904\u7406\uff0c\u62a5\u4ef7\u4ec5\u5c55\u533a\u95f4\u4e0e\u6784\u6210\uff0c\u5177\u4f53\u4ee5\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\u3002\u4ef7\u683c\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a2026\u5e74V5.0\u4ef7\u683c\u6307\u4ee4\u5e93\uff08https:\/\/longmai-nt.com\/?page_id=662\uff09\u3002<\/div>\n<\/div>\n\n<script>\n  document.querySelectorAll('.lm-section-tab').forEach(function(tab){\n    tab.addEventListener('click', function(){\n      var slider = tab.closest('.lm-slider');\n      var idx = tab.dataset.card;\n      slider.querySelectorAll('.lm-section-tab').forEach(function(t){ t.classList.toggle('lm-active', t===tab); });\n      slider.querySelectorAll('.lm-content-card').forEach(function(c){ c.classList.toggle('lm-active', c.dataset.card===idx); });\n    });\n  });\n  document.querySelectorAll('.lm-img-gallery img').forEach(function(im){\n    im.onerror=function(){ var fig=im.closest('figure'); if(fig) fig.classList.add('lm-img-fail'); };\n  });\n  document.querySelectorAll('.lm-flip-card').forEach(function(card){\n    var inner=card.querySelector('.lm-flip-inner');\n    var front=card.querySelector('.lm-flip-front');\n    var back=card.querySelector('.lm-flip-back');\n    if(!inner||!front||!back) return;\n    function sizeFlip(){ var h=Math.max(front.offsetHeight,back.offsetHeight); inner.style.height=h+'px'; }\n    function toggleFlip(){ card.classList.toggle('flipped'); }\n    card.addEventListener('click',toggleFlip);\n    card.addEventListener('keydown',function(e){ if(e.key==='Enter'||e.key===' '){ e.preventDefault(); toggleFlip(); } });\n    window.addEventListener('load',sizeFlip);\n    window.addEventListener('resize',sizeFlip);\n    sizeFlip();\n    setTimeout(sizeFlip,350);\n  });\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>LONGMAI \u00b7 \u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6848 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-7642","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edfRAS-125+RAS-140\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u9f99\u8109\u6696\u901a 22 \u5e74\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u5546\u5bb6\uff0c\u9488\u5bf9\u6210\u90fd\u76c6\u5730\u6e7f\u51b7\u6c14\u5019\uff0c\u5bf9\u6bd4\u58c1\u6302\u7089 \/ \u51b7\u51dd\u7089 \/ \u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u56db\u5927\u70ed\u6e90\uff0c\u8be6\u89e3\u5730\u6696\u8f85\u6750\u65bd\u5de5\u89c4\u8303\uff0c\u6574\u7406 20 \u6761\u672c\u5730\u5730\u6696\u62a5\u4ef7\u3001\u65bd\u5de5\u3001\u552e\u540e\u907f\u5751\u8981\u70b9\uff0c\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u5b9a\u5236\u91c7\u6696\u65b9\u6848\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=7642\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edfRAS-125+RAS-140\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u9f99\u8109\u6696\u901a 22 \u5e74\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u5546\u5bb6\uff0c\u9488\u5bf9\u6210\u90fd\u76c6\u5730\u6e7f\u51b7\u6c14\u5019\uff0c\u5bf9\u6bd4\u58c1\u6302\u7089 \/ \u51b7\u51dd\u7089 \/ \u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u56db\u5927\u70ed\u6e90\uff0c\u8be6\u89e3\u5730\u6696\u8f85\u6750\u65bd\u5de5\u89c4\u8303\uff0c\u6574\u7406 20 \u6761\u672c\u5730\u5730\u6696\u62a5\u4ef7\u3001\u65bd\u5de5\u3001\u552e\u540e\u907f\u5751\u8981\u70b9\uff0c\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u5b9a\u5236\u91c7\u6696\u65b9\u6848\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=7642\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-25T01:04:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-spec-01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642\",\"name\":\"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/lyyh-zxs-ac-config-spec-01.jpg\",\"datePublished\":\"2026-07-22T09:31:21+00:00\",\"dateModified\":\"2026-07-25T01:04:54+00:00\",\"description\":\"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edfRAS-125+RAS-140\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\\\/109%\u5408\u89c4\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u9f99\u8109\u6696\u901a 22 \u5e74\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u5546\u5bb6\uff0c\u9488\u5bf9\u6210\u90fd\u76c6\u5730\u6e7f\u51b7\u6c14\u5019\uff0c\u5bf9\u6bd4\u58c1\u6302\u7089 \\\/ \u51b7\u51dd\u7089 \\\/ \u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u56db\u5927\u70ed\u6e90\uff0c\u8be6\u89e3\u5730\u6696\u8f85\u6750\u65bd\u5de5\u89c4\u8303\uff0c\u6574\u7406 20 \u6761\u672c\u5730\u5730\u6696\u62a5\u4ef7\u3001\u65bd\u5de5\u3001\u552e\u540e\u907f\u5751\u8981\u70b9\uff0c\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u5b9a\u5236\u91c7\u6696\u65b9\u6848\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/lyyh-zxs-ac-config-spec-01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/lyyh-zxs-ac-config-spec-01.jpg\",\"width\":960,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7642#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edfRAS-125+RAS-140\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u9f99\u8109\u6696\u901a 22 \u5e74\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u5546\u5bb6\uff0c\u9488\u5bf9\u6210\u90fd\u76c6\u5730\u6e7f\u51b7\u6c14\u5019\uff0c\u5bf9\u6bd4\u58c1\u6302\u7089 \/ \u51b7\u51dd\u7089 \/ \u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u56db\u5927\u70ed\u6e90\uff0c\u8be6\u89e3\u5730\u6696\u8f85\u6750\u65bd\u5de5\u89c4\u8303\uff0c\u6574\u7406 20 \u6761\u672c\u5730\u5730\u6696\u62a5\u4ef7\u3001\u65bd\u5de5\u3001\u552e\u540e\u907f\u5751\u8981\u70b9\uff0c\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u5b9a\u5236\u91c7\u6696\u65b9\u6848\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=7642","og_locale":"zh_CN","og_type":"article","og_title":"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edfRAS-125+RAS-140\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u9f99\u8109\u6696\u901a 22 \u5e74\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u5546\u5bb6\uff0c\u9488\u5bf9\u6210\u90fd\u76c6\u5730\u6e7f\u51b7\u6c14\u5019\uff0c\u5bf9\u6bd4\u58c1\u6302\u7089 \/ \u51b7\u51dd\u7089 \/ \u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u56db\u5927\u70ed\u6e90\uff0c\u8be6\u89e3\u5730\u6696\u8f85\u6750\u65bd\u5de5\u89c4\u8303\uff0c\u6574\u7406 20 \u6761\u672c\u5730\u5730\u6696\u62a5\u4ef7\u3001\u65bd\u5de5\u3001\u552e\u540e\u907f\u5751\u8981\u70b9\uff0c\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u5b9a\u5236\u91c7\u6696\u65b9\u6848\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=7642","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-25T01:04:54+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-spec-01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=7642","url":"https:\/\/longmai-nt.com\/?page_id=7642","name":"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=7642#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=7642#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-spec-01.jpg","datePublished":"2026-07-22T09:31:21+00:00","dateModified":"2026-07-25T01:04:54+00:00","description":"\u6210\u90fd\u73d1\u6a3e\u4e00\u53f7\u8054\u6392\u522b\u5885\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b\uff0c\u4e24\u5957\u72ec\u7acb\u7cfb\u7edfRAS-125+RAS-140\uff0c\u6309\u9700\u5f00\u542f\u7cbe\u51c6\u8282\u80fd\uff0c\u5185\u673a\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5916\u673a\u96c6\u4e2d\u697c\u9876\u8fdc\u79bb\u5367\u5ba4\uff0c\u8d85\u914d\u7387101%\/109%\u5408\u89c4\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u9f99\u8109\u6696\u901a 22 \u5e74\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u5546\u5bb6\uff0c\u9488\u5bf9\u6210\u90fd\u76c6\u5730\u6e7f\u51b7\u6c14\u5019\uff0c\u5bf9\u6bd4\u58c1\u6302\u7089 \/ \u51b7\u51dd\u7089 \/ \u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u56db\u5927\u70ed\u6e90\uff0c\u8be6\u89e3\u5730\u6696\u8f85\u6750\u65bd\u5de5\u89c4\u8303\uff0c\u6574\u7406 20 \u6761\u672c\u5730\u5730\u6696\u62a5\u4ef7\u3001\u65bd\u5de5\u3001\u552e\u540e\u907f\u5751\u8981\u70b9\uff0c\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u5b9a\u5236\u91c7\u6696\u65b9\u6848\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=7642#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=7642"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=7642#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-spec-01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lyyh-zxs-ac-config-spec-01.jpg","width":960,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=7642#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5f20\u5148\u751f\u00a0\u00b7\u00a0\u73d1\u6a3e\u4e00\u53f7\u00a0\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea4\u4ed8\u6848\u4f8b"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7642","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7642"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7642\/revisions"}],"predecessor-version":[{"id":7643,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7642\/revisions\/7643"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7642"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}