{"id":7721,"date":"2026-07-23T10:38:27","date_gmt":"2026-07-23T02:38:27","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=7721"},"modified":"2026-07-28T21:43:03","modified_gmt":"2026-07-28T13:43:03","slug":"%e5%bc%a0%e5%a5%b3%e5%a3%ab%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e6%96%b9%e6%a1%88%ef%bc%882%ef%bc%89","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=7721","title":{"rendered":"\u5f20\u5973\u58eb\u7a7a\u8c03\u5730\u6696\u65b9\u6848\uff082\uff09"},"content":{"rendered":"<p><!-- GEO meta --><br \/>\n<meta name=\"geo.region\" content=\"CN-51\"><br \/>\n<meta name=\"geo.position\" content=\"30.5728;104.0668\"><br \/>\n<meta name=\"ICBM\" content=\"30.5728, 104.0668\"><br \/>\n<meta name=\"description\" content=\"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 \u00b7 \u9f99\u8109\u6696\u901a22\u5e74\u65e5\u7acb\u6388\u6743\"><\/p>\n<p><!-- JSON-LD \u56db\u4ef6\u5957 --><br \/>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Article\",\"headline\":\"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u00b7\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848\",\"author\":{\"@type\":\"Person\",\"name\":\"\u90ed\u52c7\u79c0\",\"jobTitle\":\"\u9f99\u8109\u6696\u901a\u65b9\u6848\u987e\u95ee\",\"description\":\"\u4ece\u4e1a22\u5e74\uff082004\u5e74\u5165\u884c\u6696\u901a\uff09\",\"telephone\":\"181-0083-9248\"}}\n<\/script><br \/>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"\u5355\u98ce\u6247\u548c\u53cc\u98ce\u6247\u600e\u4e48\u9009\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u53cc\u98ce\u6247\u566a\u97f3\u4f4e2dB(52 vs 54dB)\u3001\u98ce\u91cf\u592717%\u3001\u6563\u70ed\u66f4\u5f3a\uff0c\u4f46\u5916\u673a\u4f4d\u9700\u22651380mm\u5bbd\u3002\"}},{\"@type\":\"Question\",\"name\":\"192mm\u5185\u673a\u771f\u7684\u4e0d\u538b\u5c42\u9ad8\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8212\u4eabDC\u5185\u673a\u4ec5192mm\u539a\uff0c\u662f\u65e5\u7acb\u6700\u8584\u7cfb\u5217\u4e4b\u4e00\u3002\u6700\u4f4e\u53ef\u505a\u5230\u540a\u9876\u5b8c\u6210\u9762\u7ea6250mm\u3002\"}},{\"@type\":\"Question\",\"name\":\"\u5ba2\u538571+22\u53cc\u5185\u673a\u548c\u535571\u578b\u54ea\u4e2a\u597d\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"71+22\u53cc\u5185\u673a\u8986\u76d6\u66f4\u5747\u5300\u3002\u535571\u578b\u7701\u94b1\u4f46\u96c6\u4e2d\u51fa\u98ce\u3002\u63a8\u8350\u53cc\u5185\u673a\u65b9\u6848\u3002\"}},{\"@type\":\"Question\",\"name\":\"\u83f2\u65af\u66fcB1JG 25kW\u591f\u5e2687.5\u33a1\u5730\u6696\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"25kW\u51b7\u51dd\u7089\u7ef0\u7ef0\u6709\u4f59\u3002\u5168\u9884\u6df7\u51b7\u51dd\u71c3\u70e7\u6548\u7387\u2265106%\uff0c\u957f\u671f\u66f4\u7701\u3002\"}}]}<\/script><br \/>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9f99\u8109\u6696\u901a\",\"item\":\"https:\/\/longmai-nt.com\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65b9\u6848\u4e2d\u5fc3\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=3023\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\"}]}<\/script><br \/>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"LocalBusiness\",\"name\":\"\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"telephone\":\"028-86131795\",\"address\":{\"@type\":\"PostalAddress\",\"addressLocality\":\"\u6210\u90fd\",\"addressCountry\":\"CN\"}}<\/script><\/p>\n<p><!-- \u65b9\u6848\u7f16\u53f7 --><\/p>\n<div style=\"display:none;\">\u65b9\u6848\u7f16\u53f7\uff1aLM-20260726-ZNS-DS<\/div>\n<style>.hero-banner{position:relative!important;width:100%!important;min-height:380px!important;display:flex!important;align-items:center!important;justify-content:center!important;background:linear-gradient(rgba(20,18,16,0.35),rgba(20,18,16,0.65)),url(https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-07.png)!important;background-size:cover!important;background-position:50% 50%!important;background-repeat:no-repeat!important;margin-top:-220px!important}<\/style>\n<p><script>\n(function(){try{var h=document.querySelectorAll(\".entry-header\");for(var i=0;i<h.length;i++){h[i].style.display=\"none\"}var e=document.querySelector(\".entry-content\");if(e){e.style.paddingTop=\"0\";e.style.marginTop=\"0\"}}catch(ex){}})();\n<\/script><\/p>\n<style>\n<p>*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nbody{font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#333;background:#F5F7FA;line-height:1.7}\n.container{max-width:1100px;margin:0 auto;padding:0 20px}\n.header-banner .container{width:100%}<\/p>\n<p>\/* \u5934\u90e8 *\/\n.header-banner{\n  height:580px;\n  background-image:linear-gradient(rgba(20,18,16,0.35),rgba(20,18,16,0.65)),\n  url(https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-07.png);\n  background-size:auto,cover;background-position:0% 0%,50% 50%;background-repeat:repeat,no-repeat;\n  color:#fff;text-align:center;position:relative;overflow:hidden;\n  display:flex;align-items:center;justify-content:center;\n}\n.header-banner .container{width:100%}\n.header-banner h1{font-size:1.6rem;font-weight:700;margin-bottom:6px;letter-spacing:0.5px}\n.header-banner .sub{font-size:0.92rem;color:rgba(255,255,255,0.8);margin-bottom:4px}\n.header-banner .tag{font-size:0.82rem;color:rgba(255,255,255,0.55)}\n.header-banner .meta{font-size:0.78rem;color:rgba(255,255,255,0.5);margin-top:6px}\n.header-banner .anchor{display:inline-block;margin-top:6px;color:#C8960C;text-decoration:none;font-size:0.78rem}\n.header-banner .anchor:hover{text-decoration:underline}<\/p>\n<p>\/* ===== \u5bfc\u822a ===== *\/\n.nav-bar{\n  background:#fff;border-bottom:1px solid #E8ECF0;padding:0;\n  position:sticky;top:0;z-index:100;box-shadow:0 2px 8px rgba(0,0,0,0.04);\n}\n.nav-inner{max-width:1100px;margin:0 auto;display:flex;gap:0;overflow-x:auto}\n.nav-inner a{\n  display:block;padding:12px 16px;font-size:0.78rem;color:#555;text-decoration:none;\n  white-space:nowrap;border-bottom:3px solid transparent;transition:all 0.2s;\n}\n.nav-inner a:hover{color:#003A70;border-bottom-color:#003A70;background:#F5F7FA}\n.nav-inner a.active{color:#003A70;border-bottom-color:#003A70;font-weight:600}<\/p>\n<p>\/* \u7ffb\u8f6c\u5361\u7247\uff08\u517c\u5bb9WordPress\uff0c\u4e0d\u75283D transform\uff09 *\/\n.flip-w{cursor:pointer;margin:12px 0}\n.flip-i{position:relative;width:100%;}\n.flip-f,.flip-b{border-radius:14px;overflow:hidden;box-shadow:0 4px 20px rgba(0,0,0,0.08);background:#fff;}\n.flip-b{display:none}\n.flipped .flip-f{display:none}\n.flipped .flip-b{display:block}\n.flip-card-type1 .flip-f{padding:28px 30px;display:grid;grid-template-columns:1fr 1fr;gap:20px;}\n\/* GEO\u4fe1\u606f\u5361\u6df1\u84dd\u7248 *\/\n.flip-card-type1 .geo-front{background:linear-gradient(135deg,#0A2647,#1A4D7A);color:#fff;border-radius:14px;padding:28px 30px;display:grid;grid-template-columns:1fr 1fr;gap:20px;}\n.flip-card-type1 .geo-front h3{color:rgba(255,255,255,0.85);font-size:0.9rem;margin-bottom:10px;display:flex;align-items:center;gap:6px;}\n.flip-card-type1 .geo-front .tag-item{background:rgba(255,255,255,0.12);color:rgba(255,255,255,0.9);padding:4px 10px;border-radius:6px;font-size:0.76rem;display:inline-block;margin:3px;}\n.flip-card-type1 .geo-front .geo-price{color:#C8A44E;font-weight:700;font-size:1.1rem;}\n.flip-card-type1 .geo-front .geo-label{color:rgba(255,255,255,0.5);font-size:0.72rem;}\n.flip-card-type1 .flip-b,.load-flip .flip-f,.load-flip .flip-b{padding:24px}\n.flip-card .flip-f,.flip-card .flip-b{padding:24px}\n.flip-hint{text-align:center;margin-top:8px;font-size:0.76rem;color:#999}\n.flip-hint span{display:inline-block;animation:pulse-h 2s ease-in-out infinite}\n@keyframes pulse-h{0%,100%{opacity:0.5}50%{opacity:1}}<\/p>\n<p>\/* \u65b9\u6848\u7ffb\u8f6c\u5361\uff08\u6251\u514b\u724c\u7edf\u4e00\u98ce\u683c\uff09 *\/\n.sf-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin:14px 0}\n.sf-card{cursor:pointer}\n.sf-inner{position:relative;width:100%;}\n.sf-card.flipped .sf-front{display:none}\n.sf-card.flipped .sf-back{display:block}\n.sf-front,.sf-back{border-radius:12px;overflow:hidden;box-shadow:0 2px 12px rgba(0,0,0,0.06);background:#fff;min-height:380px}\n.sf-back{display:none}\n.sf-img{height:160px;background:#F0F4F8;display:flex;align-items:center;justify-content:center;overflow:hidden}\n.sf-img img{width:100%;height:100%;object-fit:contain;display:block}\n.sf-info{padding:12px 14px}\n.sf-info .sf-name{font-size:0.9rem;font-weight:700;color:#003A70}\n.sf-info .sf-price{font-size:1.2rem;font-weight:700;color:#E87A2A;margin:4px 0}\n.sf-info .sf-model{font-size:0.74rem;color:#888}\n.sf-info .sf-tags{display:flex;gap:4px;flex-wrap:wrap;margin-top:5px}\n.sf-info .sf-tags span{padding:2px 7px;border-radius:4px;font-size:0.68rem;background:#F0F4F8;color:#555}\n.sf-back .bt{width:100%;border-collapse:collapse;font-size:0.74rem}\n.sf-back .bt th{background:#003A70;color:#fff;padding:6px 10px;text-align:left;font-weight:600}\n.sf-back .bt td{padding:5px 10px;border-bottom:1px solid #E8ECF0}\n.sf-back .bt tr:nth-child(even){background:#F8FAFC}\n.sf-back .bt-total{padding:8px 12px;background:#003A70;color:#fff;display:flex;justify-content:space-between;font-size:0.8rem;font-weight:600;margin-top:auto}<\/p>\n<p>\/* \u6807\u7b7e *\/\n.tag-grid{display:flex;flex-wrap:wrap;gap:6px}\n.tag-item{display:inline-flex;align-items:center;gap:4px;padding:5px 12px;border-radius:18px;font-size:0.78rem;background:#F0F4F8;color:#003A70;border:1px solid #DCE4EC}\n.tag-item .e{font-size:0.9rem}<\/p>\n<p>\/* \u677f\u5757 *\/\n.section{margin:32px 0;padding:0 20px}\n.section-inner{background:#fff;border-radius:14px;padding:32px;box-shadow:0 2px 12px rgba(0,0,0,0.05);position:relative;border-left:5px solid #DDD}\n.s1{border-left-color:#003A70}\n.s2{border-left-color:#E87A2A}\n.s3{border-left-color:#27AE60}\n.s4{border-left-color:#C8960C}\n.s5{border-left-color:#7C3AED}\n.section-title{font-size:1.3rem;font-weight:700;color:#003A70;margin-bottom:4px}\n.section-sub{font-size:0.85rem;color:#888;margin-bottom:20px;padding-bottom:12px;border-bottom:2px solid #F0F2F5}<\/p>\n<p>\/* \u786e\u8ba4\u6846 *\/\n.confirm-box{background:#F5F7FA;border:1px solid #E0E4E8;border-radius:10px;padding:12px 18px;margin-top:20px;font-size:0.82rem;color:#666;text-align:center}<\/p>\n<p>\/* \u56db\u5217\u75db\u70b9\u5361\u7247 *\/\n.pain-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:14px;margin:14px 0}\n.pain-card{border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,0.05);border:1px solid #E8ECF0}\n.pain-card .pc-head{padding:9px 14px;color:#fff;display:flex;align-items:center;gap:6px;font-size:0.84rem;font-weight:600}\n.pain-card:nth-child(1) .pc-head{background:#003A70}\n.pain-card:nth-child(2) .pc-head{background:#E87A2A}\n.pain-card:nth-child(3) .pc-head{background:#27AE60}\n.pain-card:nth-child(4) .pc-head{background:#C8960C}\n.pain-card .pc-body{padding:12px 14px}\n.pain-card .pc-row{display:flex;gap:6px;padding:4px 0;font-size:0.8rem;line-height:1.5}\n.pain-card .pc-row .pc-label{flex-shrink:0;width:55px;font-weight:600;color:#003A70;font-size:0.75rem}\n.pain-card .pc-row .pc-val{flex:1;color:#555}<\/p>\n<p>\/* \u7ea2\u7ebf\u5361\u7247 *\/\n.redline-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0}\n.redline-card{border-radius:10px;padding:16px;border:2px solid #DC2626;background:#FEF2F2;position:relative}\n.redline-card::before{content:'\ud83d\udeab \u7ea2\u7ebf';position:absolute;top:-10px;left:12px;background:#DC2626;color:#fff;padding:2px 10px;border-radius:4px;font-size:0.7rem;font-weight:700}\n.redline-card .rl-title{font-size:0.87rem;font-weight:700;color:#991B1B;margin:6px 0 5px}\n.redline-card .rl-desc{font-size:0.78rem;color:#7F1D1D;line-height:1.5}<\/p>\n<p>\/* \u5bf9\u6bd4\u8868 *\/\n.comp-table{width:100%;border-collapse:collapse;margin:14px 0}\n.comp-table th{background:#003A70;color:#fff;padding:9px 12px;text-align:center;font-weight:600;font-size:0.82rem}\n.comp-table th:first-child{border-radius:8px 0 0 0;text-align:left}\n.comp-table th:last-child{border-radius:0 8px 0 0}\n.comp-table td{padding:9px 12px;text-align:center;border-bottom:1px solid #E8ECF0;font-size:0.82rem}\n.comp-table td:first-child{text-align:left;font-weight:600;color:#003A70}\n.comp-table tr:nth-child(even){background:#F8FAFC}\n.comp-table .disclosure{background:#FFF3E0!important}\n.comp-table .disclosure td{color:#E87A2A;font-size:0.76rem}<\/p>\n<p>\/* \u8d1f\u8377\u8868 *\/\n.ld-table{width:100%;border-collapse:collapse;font-size:0.8rem}\n.ld-table th{background:#003A70;color:#fff;padding:7px 10px;text-align:center;font-weight:600}\n.ld-table td{padding:7px 10px;text-align:center;border-bottom:1px solid #E8ECF0}\n.ld-table tr:nth-child(even){background:#F8FAFC}\n.ld-table .total{background:#E8F0FE!important;font-weight:600}\n.ld-note{background:#E8F5E9;border-left:4px solid #27AE60;padding:9px 12px;border-radius:6px;font-size:0.8rem;margin:8px 0}<\/p>\n<p>\/* \u77e9\u9635 *\/\n.matrix{width:100%;border-collapse:collapse;margin:14px 0}\n.matrix th{background:#003A70;color:#fff;padding:10px 12px;text-align:center;font-weight:600;font-size:0.82rem}\n.matrix th:first-child{border-radius:8px 0 0 0;text-align:left}\n.matrix th:last-child{border-radius:0 8px 0 0}\n.matrix td{padding:10px 12px;text-align:center;border-bottom:1px solid #E8ECF0;font-size:0.82rem}\n.matrix .rl{text-align:left;font-weight:600;color:#003A70}\n.matrix .rl small{font-weight:400;display:block;font-size:0.7rem;color:#999}\n.matrix .hl{background:#FFF8E1!important;font-weight:700;color:#C8960C}\n.matrix tr:nth-child(even){background:#F8FAFC}<\/p>\n<p>\/* \u4e3b\u63a8\u4e09\u6863 *\/\n.rec-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin:14px 0}\n.rec-card{border-radius:12px;overflow:hidden;box-shadow:0 2px 12px rgba(0,0,0,0.06);border:2px solid #E8ECF0;text-align:center}\n.rec-card.feat{border-color:#C8960C;position:relative}\n.rec-card.feat::before{content:'\u2605 \u63a8\u8350';position:absolute;top:-1px;right:12px;background:#C8960C;color:#fff;padding:2px 12px;font-size:0.68rem;border-radius:0 0 6px 6px;z-index:2}\n.rec-card .rh{padding:12px 14px;color:#fff}\n.rec-eco .rh{background:#27AE60}\n.rec-bal .rh{background:#003A70}\n.rec-sav .rh{background:#C8960C}\n.rec-card .rh .rt{font-size:0.95rem;font-weight:700}\n.rec-card .rh .rs{font-size:0.7rem;opacity:0.85}\n.rec-card .rb{padding:12px}\n.rec-card .rb .rp{font-size:1.4rem;font-weight:700;color:#003A70}\n.rec-card .rb .rd{font-size:0.78rem;color:#666;margin:5px 0;line-height:1.5}\n.rec-card .rb .rbk{font-size:0.74rem;color:#999}<\/p>\n<p>\/* 20\u5e74\u603b\u8d26 *\/\n.lcc-w{cursor:pointer;margin:14px 0}\n.lcc-i{position:relative;width:100%}\n.lcc-w.flipped .lcc-f{display:none}\n.lcc-w.flipped .lcc-b{display:block}\n.lcc-f,.lcc-b{border-radius:12px;overflow:hidden;box-shadow:0 2px 12px rgba(0,0,0,0.06);background:#fff}\n.lcc-b{display:none}\n.lcc-f .lh{background:linear-gradient(135deg,#003A70,#1A5C9E);color:#fff;padding:14px 20px}\n.lcc-f .lh h3{font-size:0.95rem;margin-bottom:2px}\n.lcc-f .lh .lhint{font-size:0.7rem;opacity:0.7}\n.lcc-f .lb{padding:20px}\n.lcc-f .fm{background:#F5F7FA;border-radius:8px;padding:12px 16px;margin-bottom:8px;font-size:0.8rem}\n.lcc-f .fm .f{font-weight:700;color:#003A70}\n.lcc-f .fm .v{font-size:0.74rem;color:#666;margin-top:4px}\n.lcc-b .lbb{padding:20px}\n.lcc-b .lct{width:100%;border-collapse:collapse}\n.lcc-b .lct th{background:#003A70;color:#fff;padding:8px 10px;text-align:center;font-size:0.78rem}\n.lcc-b .lct td{padding:8px 10px;text-align:center;border-bottom:1px solid #E8ECF0;font-size:0.78rem}\n.lcc-b .lct tr:nth-child(even){background:#F8FAFC}\n.lcc-b .lct .tot{background:#E8F0FE!important;font-weight:700;color:#003A70}<\/p>\n<p>\/* \u65bd\u5de5 *\/\n.steps{display:grid;grid-template-columns:repeat(5,1fr);gap:10px;margin:14px 0}\n.step{text-align:center;background:#F8FAFC;border-radius:10px;padding:14px 8px;border:1px solid #E8ECF0}\n.step .sn{width:32px;height:32px;border-radius:50%;background:#003A70;color:#fff;display:flex;align-items:center;justify-content:center;margin:0 auto 6px;font-weight:700;font-size:0.82rem}\n.step .sname{font-size:0.8rem;font-weight:700;color:#003A70;margin-bottom:2px}\n.step .sdesc{font-size:0.7rem;color:#888}<\/p>\n<p>\/* \u5b9e\u666f6\u4e2a *\/\n.gallery{display:grid;grid-template-columns:repeat(3,1fr);gap:8px;margin:12px 0}\n.gallery .g-item{background:#F0F4F8;border-radius:8px;height:85px;display:flex;align-items:center;justify-content:center;font-size:0.65rem;color:#aaa;flex-direction:column;gap:3px;border:1px dashed #DCE4EC}\n.gallery .g-item .g-icon{font-size:1.3rem}<\/p>\n<p>\/* \u516d\u7ef4 *\/\n.dim-g{display:grid;grid-template-columns:repeat(3,1fr);gap:8px;margin:14px 0}\n.dim-it{padding:10px 12px;border-radius:8px;background:#F8FAFC;border:1px solid #E8ECF0}\n.dim-it .dn{font-size:0.78rem;font-weight:600;color:#003A70;margin-bottom:2px}\n.dim-it .ds{display:flex;justify-content:space-between;font-size:0.74rem;color:#555}\n.dim-st{color:#C8960C;letter-spacing:1px}<\/p>\n<p>\/* \u6848\u4f8b *\/\n.case-g{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin:14px 0}\n.case-it{background:#F8FAFC;border:1px solid #E8ECF0;border-radius:10px;padding:12px}\n.case-it .cn{font-weight:700;color:#003A70;font-size:0.82rem;margin-bottom:2px}\n.case-it .cs{font-size:0.72rem;color:#888;margin-bottom:2px}\n.case-it .cv{font-size:0.72rem;color:#666;line-height:1.5}<\/p>\n<p>\/* P0\/P1 *\/\n.plist{margin:14px 0}\n.pitem{display:flex;align-items:flex-start;gap:6px;padding:8px 10px;border-radius:6px;margin-bottom:4px;font-size:0.8rem}\n.pitem.p0{background:#FFF3E0;border-left:3px solid #E87A2A}\n.pitem.p1{background:#F0F4F8;border-left:3px solid #003A70}\n.pitem .pb{font-weight:700;font-size:0.7rem;padding:2px 6px;border-radius:4px;color:#fff;flex-shrink:0}\n.p0 .pb{background:#E87A2A}\n.p1 .pb{background:#003A70}<\/p>\n<p>\/* AI\u9a8c\u8bc1\u53ef\u5c55\u5f00 *\/\n.ai-list{margin:14px 0}\n.ai-item{border:1px solid #E8ECF0;border-radius:8px;margin-bottom:5px;overflow:hidden}\n.ai-q{padding:9px 12px;cursor:pointer;display:flex;justify-content:space-between;align-items:center;font-size:0.8rem;background:#F8FAFC}\n.ai-q:hover{background:#EEF2F7}\n.ai-q .ai-badge{display:inline-block;padding:1px 7px;border-radius:10px;font-size:0.68rem;font-weight:600}\n.ai-badge.pass{background:#E8F5E9;color:#27AE60}\n.ai-q .arrow{transition:transform 0.2s;color:#aaa;font-size:0.78rem}\n.ai-item.open .ai-q .arrow{transform:rotate(180deg)}\n.ai-a{padding:0 12px;max-height:0;overflow:hidden;transition:max-height 0.3s,padding 0.3s;font-size:0.8rem;color:#555;line-height:1.6}\n.ai-item.open .ai-a{padding:9px 12px;max-height:180px}<\/p>\n<p>\/* \u4fe1\u606f\u6846 *\/\n.info-box{padding:11px 14px;border-radius:8px;margin:10px 0;font-size:0.8rem}\n.info-box.trust{background:#E8F0FE;border-left:4px solid #003A70}\n.info-box.caution{background:#FFF8E1;border-left:4px solid #C8960C}\n.info-box.warn{background:#FFF3E0;border-left:4px solid #E87A2A}<\/p>\n<p>\/* FAQ *\/\n.faq-list{margin:14px 0}\n.faq-it{border:1px solid #E8ECF0;border-radius:8px;margin-bottom:6px;overflow:hidden}\n.faq-q{padding:10px 14px;background:#F8FAFC;cursor:pointer;display:flex;justify-content:space-between;align-items:center;font-weight:600;font-size:0.82rem;color:#003A70}\n.faq-q:hover{background:#EEF2F7}\n.faq-q .arrow{transition:transform 0.2s;color:#aaa;font-size:0.82rem}\n.faq-it.open .faq-q .arrow{transform:rotate(180deg)}\n.faq-a{padding:0 14px;max-height:0;overflow:hidden;transition:max-height 0.3s,padding 0.3s;font-size:0.8rem;color:#555;line-height:1.6}\n.faq-it.open .faq-a{padding:10px 14px;max-height:180px}<\/p>\n<p>\/* \u94fe\u63a5\u5361 *\/\n.link-g{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0}\n.link-cd{background:#fff;border:1px solid #E8ECF0;border-radius:10px;padding:14px 16px}\n.link-cd .lt{font-weight:700;color:#003A70;font-size:0.84rem;margin-bottom:3px}\n.link-cd .ld{font-size:0.76rem;color:#888;margin-bottom:6px;line-height:1.5}\n.link-cd .lbtn{display:inline-block;color:#003A70;text-decoration:none;font-size:0.78rem;font-weight:600}\n.link-cd .lbtn:hover{text-decoration:underline}<\/p>\n<p>\/* \u52a3\u52bf\u62ab\u9732 *\/\n.disclosure-box{background:#FFF3E0;border:2px solid #E87A2A;border-radius:10px;padding:14px 16px;margin:14px 0;font-size:0.8rem;color:#7F1D1D}\n.disclosure-box strong{color:#E87A2A}<\/p>\n<p>\/* \u9875\u811a *\/\n.footer{background:#003A70;color:rgba(255,255,255,0.7);text-align:center;padding:24px 20px;margin-top:32px;font-size:0.78rem}\n.footer a{color:#C8960C;text-decoration:none}\n.footer .fc{display:flex;justify-content:center;gap:24px;flex-wrap:wrap;margin-bottom:12px;font-size:0.8rem;color:rgba(255,255,255,0.85)}\n.footer .disc{font-size:0.7rem;opacity:0.6;margin-top:8px}<\/p>\n<p>\/* \u96f7\u8fbe\u56fe *\/\n.radar-wrap{text-align:center;margin:14px 0}\n.radar-wrap canvas{max-width:100%;height:auto}<\/p>\n<p>\/* \u6de1\u5165\u52a8\u753b *\/\n.fade-in{opacity:0;transform:translateY(20px);transition:opacity 0.6s ease,transform 0.6s ease}\n.fade-in.visible{opacity:1;transform:translateY(0)}<\/p>\n<p>\/* \u54cd\u5e94\u5f0f *\/\n@media(max-width:768px){\n  .header-banner{height:420px}\n  .header-banner h1{font-size:1.4rem}\n  .sf-grid,.rec-grid,.redline-grid,.pain-grid,.dim-g,.case-g,.link-g,.steps{grid-template-columns:1fr}\n  .gallery{grid-template-columns:repeat(2,1fr)}\n  .flip-card-type1 .flip-f{grid-template-columns:1fr}\n  .section-inner{padding:20px 12px}\n  .nav-inner a{padding:10px 12px;font-size:0.72rem}\n}<\/p>\n<p>\/* \u6253\u5370\u4f18\u5316 *\/\n@media print{\n  .nav-bar{display:none}\n  .flip-w,.sf-card,.lcc-w{break-inside:avoid}\n  .section{page-break-inside:avoid}\n  .confirm-box{display:none}\n  \/* \u6253\u5370\u65f6\u5c55\u5f00\u6240\u6709\u7ffb\u8f6c\u5361\u7247 *\/\n  .flip-f,.sf-front,.lcc-f{display:none!important}\n  .flip-b,.sf-back,.lcc-b{display:block!important}\n  .section-inner{box-shadow:none;border:1px solid #ddd}\n  .header-banner{background:#003A70!important;-webkit-print-color-adjust:exact;print-color-adjust:exact}\n  .pain-card .pc-head,.redline-card::before,.comp-table th,.ld-table th,.matrix th,.sf-back .bt th,.lcc-b .lct th,.lcc-f .lh,.step .sn{background:#003A70!important;-webkit-print-color-adjust:exact;print-color-adjust:exact}\n  .gallery .g-item{border:1px solid #ddd;background:#f5f5f5!important}\n  .footer{background:#003A70!important;-webkit-print-color-adjust:exact;print-color-adjust:exact}\n}<\/p>\n<p>\/* ===== \u65b0\u589e\u82f1\u96c4\u680f ===== *\/\n.hero-banner{position:relative!important;height:400px!important;width:100%!important;overflow:hidden!important}\n\/* \u82f1\u96c4\u680f\u6587\u5b57\uff08flexbox\u5c45\u4e2d\uff0c\u4e0d\u7528absolute\uff09 *\/\n.hero-banner .hero-text{text-align:center!important;color:#fff!important;text-shadow:0 1px 6px rgba(0,0,0,0.75)!important;width:90%!important}\n.hero-banner h1{font-size:1.6rem!important;font-weight:700!important;margin:0 0 6px!important;color:#fff!important}\n.hero-banner .sub{font-size:0.92rem!important;color:rgba(255,255,255,0.85)!important;margin-bottom:4px!important}\n.hero-banner .tag{font-size:0.82rem!important;color:#C8960C!important}\n.hero-banner .meta{font-size:0.78rem!important;color:rgba(255,255,255,0.5)!important;margin-top:6px!important}\n@media(max-width:768px){.hero-banner{min-height:280px!important}.hero-banner h1{font-size:1.3rem!important}}\n\/* ===== \u65b0\u589e\u5bfc\u822a ===== *\/\n.lm-nav{background:#fff!important;border-bottom:1px solid #e2e8f0!important;position:sticky!important;top:0!important;z-index:99999!important;box-shadow:0 2px 12px rgba(0,0,0,0.1)!important;display:flex!important;width:100%!important;padding:0 20px!important;box-sizing:border-box!important}\n.lm-nav-inner{display:flex!important;max-width:1100px!important;margin:0 auto!important;width:100%!important}\n.lm-nav-item{position:relative!important;flex-shrink:0!important;display:block!important}\n.lm-nav-item summary{list-style:none!important;display:block!important;cursor:pointer!important;padding:0!important}\n.lm-nav-item summary::-webkit-details-marker{display:none!important}\n.lm-nav-item summary::marker{display:none!important;content:''!important}\n.lm-nav-toggle{display:block!important;padding:12px 16px!important;font-size:0.8rem!important;color:#555!important;white-space:nowrap!important;border-bottom:3px solid transparent!important}\n.lm-nav-toggle:hover,.lm-nav-item[open] .lm-nav-toggle{color:#003A70!important;border-bottom-color:#003A70!important;background:#F5F7FA!important}\n.lm-caret{font-size:0.7rem!important;margin-left:3px!important}\n.lm-nav-panel{position:absolute!important;top:100%!important;left:0!important;min-width:220px!important;background:#fff!important;border:1px solid #e2e8f0!important;border-radius:8px!important;box-shadow:0 8px 24px rgba(0,0,0,0.15)!important;z-index:99999!important;padding:6px 0!important}\n.lm-nav-panel a{display:block!important;padding:8px 16px!important;font-size:0.78rem!important;color:#2d3748!important;text-decoration:none!important;border-left:3px solid transparent!important}\n.lm-nav-panel a:hover{background:#F5F7FA!important;color:#003A70!important;border-left-color:#003A70!important}\n@media(max-width:768px){.lm-nav{overflow-x:auto!important;padding:0!important}}\n.section,.section h2,.section h3,.section h4{scroll-margin-top:60px!important}<\/p>\n<p>.flipped .geo-front{display:none!important}\n.flipped .card-info{display:none!important}\n.flipped .card-skill{display:none!important}\n.flipped .flip-f{display:none!important}\n.flipped .flip-b{display:block!important}\n.flipped .sf-front{display:none!important}\n.flipped .sf-back{display:flex!important}\n.flipped .lcc-f{display:none!important}\n.flipped .lcc-b{display:block!important}<\/p>\n<p>\/* lm-flip-card\u7ffb\u8f6c *\/\n.lm-flip-card{cursor:pointer;margin:12px 0;perspective:1000px}\n.lm-flip-inner{position:relative;width:100%;min-height:280px;transition:transform 0.6s ease;transform-style:preserve-3d}\n.flipped .lm-flip-inner{transform:rotateY(180deg)}\n.lm-flip-front,.lm-flip-back{position:absolute;top:0;left:0;width:100%;min-height:100%;backface-visibility:hidden;border-radius:14px;overflow:hidden;box-shadow:0 4px 20px rgba(0,0,0,0.08);background:#fff}\n.lm-flip-back{transform:rotateY(180deg)}\n\/* \u65b0\u589e\u82f1\u96c4\u680f\uff08\u5df2\u5728\u8865\u4e01\u4e2d\u5b9a\u4e49\uff0c\u8fd9\u91cc\u4fdd\u7559\u54cd\u5e94\u5f0f\u9002\u914d\uff09 *\/\n@media(max-width:768px){.hero-banner{min-height:280px!important}}\n<\/style>\n<div class=\"hero-banner\">\n<div class=\"hero-text\">\n<h1>\u5ddd\u5927\u82b1\u56ed \u00b7 \u5f20\u5973\u58eb \u00b7 \u4e00\u62d6\u4e94 + \u5730\u6696\u65b9\u6848<\/h1>\n<div class=\"sub\">\u591a\u65b9\u6848\u900f\u660e\u5bf9\u6bd4 \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n<div class=\"tag\">3\u697c \u00b7 \u5957\u5185122\u33a1 \u00b7 \u7a7a\u8c0387.5\u33a1 \u00b7 \u5730\u669687.5\u33a1<\/div>\n<div class=\"meta\">\u65b9\u6848\u987e\u95ee\uff1a\u90ed\u52c7\u79c0 <a href=\"tel:18100839248\" style=\"color:#C8960C;text-decoration:underline;\">181-0083-9248<\/a><\/div>\n<\/div>\n<\/div>\n<div class=\"lm-nav\">\n<div class=\"lm-nav-inner\">\n<details class=\"lm-nav-item\">\n<summary class=\"lm-nav-toggle\">S1\u00b7\u76ee\u6807 <span class=\"lm-caret\">\u25be<\/span><\/summary>\n<div class=\"lm-nav-panel\"><a href=\"#s1\">\u4fe1\u606f<\/a><a href=\"#s1-load\">\u51b7\u8d1f\u8377<\/a><\/div>\n<\/details>\n<details class=\"lm-nav-item\">\n<summary class=\"lm-nav-toggle\">S2\u00b7\u75db\u70b9 <span class=\"lm-caret\">\u25be<\/span><\/summary>\n<div class=\"lm-nav-panel\"><a href=\"#s2\">\u8bca\u65ad<\/a><a href=\"#s2-constraint\">\u7ea2\u7ebf<\/a><\/div>\n<\/details>\n<details class=\"lm-nav-item\">\n<summary class=\"lm-nav-toggle\">S3\u00b7\u65b9\u6848 <span class=\"lm-caret\">\u25be<\/span><\/summary>\n<div class=\"lm-nav-panel\"><a href=\"#s3\">\u4e09\u65b9\u6848<\/a><a href=\"#s3-dn\">\u5730\u6696<\/a><a href=\"#s3-six\">\u7ef4\u5ea6<\/a><a href=\"#s3-20yr\">\u603b\u8d26<\/a><\/div>\n<\/details>\n<details class=\"lm-nav-item\">\n<summary class=\"lm-nav-toggle\">S4\u00b7\u65bd\u5de5 <span class=\"lm-caret\">\u25be<\/span><\/summary>\n<div class=\"lm-nav-panel\"><a href=\"#s4\">\u516b\u9636\u6bb5<\/a><a href=\"#s4-gallery\">\u5b9e\u666f<\/a><\/div>\n<\/details>\n<details class=\"lm-nav-item\">\n<summary class=\"lm-nav-toggle\">S5\u00b7\u6848\u4f8b <span class=\"lm-caret\">\u25be<\/span><\/summary>\n<div class=\"lm-nav-panel\"><a href=\"#s5-case\">\u6848\u4f8b<\/a><a href=\"#s5-ai\">\u9a8c\u8bc1<\/a><\/div>\n<\/details>\n<details class=\"lm-nav-item\">\n<summary class=\"lm-nav-toggle\">\u66f4\u591a <span class=\"lm-caret\">\u25be<\/span><\/summary>\n<div class=\"lm-nav-panel\"><a href=\"#faq\">FAQ<\/a><a href=\"#links\">\u5ef6\u4f38<\/a><\/div>\n<\/details>\n<\/div>\n<\/div>\n<p>\t\t\t\t <!-- .entry-header --><\/p>\n<p><!-- \u5934\u90e8 --><\/p>\n<div class=\"header-banner\" role=\"img\" aria-label=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f - \u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab\u65b9\u6848\">\n<div class=\"container\">\n<h1>\u5ddd\u5927\u82b1\u56ed \u00b7 \u5f20\u5973\u58eb \u00b7 \u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u4e94 + \u5730\u6696\u65b9\u6848<\/h1>\n<div class=\"sub\">\u591a\u65b9\u6848\u900f\u660e\u5bf9\u6bd4 \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n<div class=\"tag\">3\u697c\u00b7\u5957\u5185122\u33a1\u00b7\u7a7a\u8c0387.5\u33a1\u00b7\u5730\u669687.5\u33a1\u00b7\u4e00\u6b65\u5230\u4f4d\u00b7\u5c42\u9ad8\u53cb\u597d<\/div>\n<div class=\"meta\">\u65b9\u6848\u987e\u95ee\uff1a\u90ed\u52c7\u79c0 <a href=\"tel:18100839248\" style=\"color:inherit;text-decoration:underline;\">181-0083-9248<\/a> \uff5c \u51fa\u5177\u65e5\u671f\uff1a2026\u5e747\u670825\u65e5\uff08\u54c1\u724c\u6708\u6d3b\u52a8\u671f\u5185\uff09<\/div>\n<p>    <a class=\"anchor\" href=\"#content\">\u2193 \u8df3\u81f3\u5185\u5bb9<\/a>\n  <\/div>\n<\/div>\n<\/div>\n<div id=\"content\" class=\"container\">\n<p><!-- ========================================================== --><br \/>\n<!-- \u7c7b\u578b1 \u9879\u76ee\u901f\u89c8\u5361 --><br \/>\n<!-- ========================================================== --><\/p>\n<div class=\"flip-w\" style=\"margin-top:24px\">\n<div class=\"flip-card-type1\" >\n<div class=\"flip-i\">\n<div class=\"geo-front\">\n<div>\n<h3>\ud83c\udff7\ufe0f \u9879\u76ee\u753b\u50cf<\/h3>\n<div class=\"tag-grid\">\n            <span class=\"tag-item\">\ud83d\udc64 \u5f20\u5973\u58eb\uff08\u5ddd\u5927\u82b1\u56ed\uff09<\/span><br \/>\n            <span class=\"tag-item\">\ud83c\udfe0 3\u697c \u00b7 \u5957\u5185122\u33a1 \u00b7 3\u4eba\u5e38\u4f4f<\/span><br \/>\n            <span class=\"tag-item\">\u2744\ufe0f \u8212\u4eab140 \u00b7 \u4e00\u62d6\u4e94 \u00b7 \u8d85\u914d122.9%<\/span><br \/>\n            <span class=\"tag-item\">\ud83d\udd25 \u5730\u669687.5\u33a1 \u00b7 \u83f2\u65af\u66fcB1JG<\/span><br \/>\n            <span class=\"tag-item\">\ud83c\udfaf \u5c42\u9ad8\u53cb\u597d \u00b7 \u7f8e\u89c2 \u00b7 \u4ef7\u683c\u9002\u4e2d<\/span><br \/>\n            <span class=\"tag-item\">\u2696\ufe0f 2\u79cd\u7a7a\u8c03 \u00d7 3\u6863\u5730\u6696 \u00d7 3\u6b3e\u9505\u7089<\/span>\n          <\/div>\n<\/p><\/div>\n<div>\n<h3>\u2699\ufe0f \u65b9\u6848\u8981\u70b9<\/h3>\n<div class=\"tag-grid\">\n            <span class=\"tag-item\">\ud83d\udccd \u5ddd\u5927\u82b1\u56ed \u00b7 3\u697c \u00b7 \u5df2\u6253\u62c6<\/span><br \/>\n            <span class=\"tag-item\">\ud83c\udfe0 \u7a7a\u8c0387.5\u33a1 \/ \u5730\u669687.5\u33a1<\/span><br \/>\n            <span class=\"tag-item\">\u2744\ufe0f \u539f\u59cb\u60f3\u6cd5\/\u6027\u4ef7\u6bd4\u63a8\u8350\/20\u5e74\u957f\u6548<\/span><br \/>\n            <span class=\"tag-item\">\ud83d\udd25 \u83f2\u65af\u66fcB1JG 25kW\u51b7\u51dd\u7089<\/span><br \/>\n            <span class=\"tag-item\" style=\"background:rgba(196,164,78,0.2);border:1px solid rgba(196,164,78,0.3);\"><span class=\"geo-label\">\u63a8\u8350\u7ec4\u5408<\/span> <span class=\"geo-price\">\u2248\u00a554,868<\/span><\/span>\n          <\/div>\n<p style=\"font-size:0.7rem;color:rgba(255,255,255,0.4);margin-top:8px;\">\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\uff0c\u67e5\u770b\u8be6\u7ec6\u914d\u7f6e<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"flip-b\" style=\"padding:28px 30px;\">\n<h3 style=\"font-size:0.9rem;color:#003A70;margin-bottom:10px;\">\ud83d\udccb \u9879\u76ee\u8be6\u7ec6\u914d\u7f6e<\/h3>\n<table style=\"width:100%;border-collapse:collapse;font-size:0.8rem;\">\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;width:110px;\">\u9879\u76ee\u5730\u5740<\/td>\n<td style=\"padding:5px 10px;\">\u5ddd\u5927\u82b1\u56ed \u00b7 3\u697c \u00b7 \u5df2\u6253\u62c6\u5b8c\u6bd5<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u4e1a\u4e3b<\/td>\n<td style=\"padding:5px 10px;\">\u5f20\u5973\u58eb\uff08\u5ddd\u5927\u82b1\u56ed\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u5e38\u4f4f\u4eba\u53e3<\/td>\n<td style=\"padding:5px 10px;\">3\u4eba\uff08\u592b\u5987+\u5973\u513f\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u88c5\u4fee\u9636\u6bb5<\/td>\n<td style=\"padding:5px 10px;\">\u5df2\u6253\u62c6\u5b8c\u6bd5<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u5957\u5185\u9762\u79ef<\/td>\n<td style=\"padding:5px 10px;\">122\u33a1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u7a7a\u8c03\u9762\u79ef<\/td>\n<td style=\"padding:5px 10px;\">87.5\u33a1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u5730\u6696\u9762\u79ef<\/td>\n<td style=\"padding:5px 10px;\">87.5\u33a1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u7cfb\u7edf\u7c7b\u578b<\/td>\n<td style=\"padding:5px 10px;\">\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94 + \u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;font-weight:600;color:#555;\">\u5173\u6ce8\u91cd\u70b9<\/td>\n<td style=\"padding:5px 10px;\">\u5c42\u9ad8\u53cb\u597d(192mm) \u00b7 \u7f8e\u89c2 \u00b7 \u4ef7\u683c\u9002\u4e2d \u00b7 \u6c14\u6d41\u5747\u5300<\/td>\n<\/tr>\n<\/table><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"flip-hint\"><span>\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c<\/span><\/div>\n<\/div>\n<p><!-- ========================================================== --><br \/>\n<!-- S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807\n\n\n\n<p style=\"font-size:0.75rem;color:#888;border-left:3px solid #003A70;padding-left:10px;margin:6px 0;\">\ud83d\udccc \u539f\u59cb\u60f3\u6cd5\uff08\u539f\u59cb\u9700\u6c42\uff09\uff1a2026-07-25 \u5ba2\u6237\u521d\u6b21\u63d0\u51fa\u7684\u914d\u7f6e\u9700\u6c42\uff08\u8212\u4eab140\u4e00\u62d6\u4e94 + \u5168\u5c4b\u5730\u669687.5\u33a1\uff09<\/p>\n\n --><br \/>\n<!-- ========================================================== --><\/p>\n<div class=\"section\" id=\"s1\">\n<div class=\"section-inner s1\">\n<div class=\"section-title\">S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n<div class=\"section-sub\">\u7406\u89e3\u9700\u6c42 \u00b7 \u8bbe\u5b9a\u53ef\u9a8c\u8bc1\u627f\u8bfa<\/div>\n<p>    <!-- \u5ba2\u6237\u76ee\u6807\u7ffb\u8f6c\u5361 --><\/p>\n<div class=\"flip-w\">\n<div class=\"flip-card\" >\n<div class=\"flip-i\" style=\"min-height:280px;\">\n<div class=\"flip-f\">\n<div style=\"background:linear-gradient(135deg,#0A2647,#1A4D7A);border-radius:14px;padding:24px;color:#fff;\">\n<h4 style=\"font-size:0.9rem;color:rgba(255,255,255,0.9);margin-bottom:12px;\">\ud83c\udff7\ufe0f \u5ba2\u6237\u4fe1\u606f\u5361<\/h4>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:8px;font-size:0.8rem;\">\n<div><span style=\"color:rgba(255,255,255,0.5);font-size:0.72rem;\">\u4e1a\u4e3b<\/span><br \/>\u5f20\u5973\u58eb\uff08\u5ddd\u5927\u82b1\u56ed\uff09\uff0c\u592b\u5987+\u5973\u513f3\u4eba<\/div>\n<div><span style=\"color:rgba(255,255,255,0.5);font-size:0.72rem;\">\u623f\u5c4b<\/span><br \/>3\u697c \u00b7 \u5957\u5185122\u33a1 \u00b7 \u5df2\u6253\u62c6\u5b8c\u6bd5<\/div>\n<div><span style=\"color:rgba(255,255,255,0.5);font-size:0.72rem;\">\u9700\u6c42<\/span><br \/>\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u4e94 + \u5168\u5c4b\u5730\u6696<\/div>\n<div><span style=\"color:rgba(255,255,255,0.5);font-size:0.72rem;\">\u6838\u5fc3\u8bc9\u6c42<\/span><br \/>\u4e00\u6b65\u5230\u4f4d \u00b7 \u5c42\u9ad8\u53cb\u597d \u00b7 \u7f8e\u89c2<\/div>\n<div><span style=\"color:rgba(255,255,255,0.5);font-size:0.72rem;\">\u5173\u6ce8\u7126\u70b9<\/span><br \/>192mm\u8584\u578b\u5185\u673a \/ \u4ef7\u683c \/ \u6c14\u6d41\u5747\u5300<\/div>\n<div><span style=\"color:rgba(255,255,255,0.5);font-size:0.72rem;\">\u65b9\u6848\u987e\u95ee<\/span><br \/>\u90ed\u52c7\u79c0 <a href=\"tel:18100839248\" style=\"color:#C8A44E;text-decoration:underline;\">181-0083-9248<\/a><\/div>\n<\/p><\/div>\n<div style=\"color:rgba(255,255,255,0.4);font-size:0.7rem;margin-top:10px;text-align:center;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u6210\u529f\u76ee\u6807<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"flip-b\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:10px;\">\ud83c\udfaf \u5ba2\u6237\u6210\u529f\u76ee\u6807\uff08\u53ef\u9a8c\u8bc1\u627f\u8bfa\uff09<\/h4>\n<table style=\"width:100%;border-collapse:collapse;font-size:0.8rem;\">\n<tr>\n<th style=\"background:#003A70;color:#fff;padding:7px 10px;text-align:left;width:20%;\">#<\/th>\n<th style=\"background:#003A70;color:#fff;padding:7px 10px;text-align:left;\">\u76ee\u6807<\/th>\n<th style=\"background:#003A70;color:#fff;padding:7px 10px;text-align:left;\">\u9a8c\u8bc1\u65b9\u5f0f<\/th>\n<\/tr>\n<tr>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u2460<\/td>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u5168\u5c4b\u4e00\u62d6\u4e94\u72ec\u7acb\u6e29\u63a7\uff0c\u6bcf\u4e2a\u623f\u95f4\u6309\u9700\u542f\u505c<\/td>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">5\u53f0\u5185\u673a\u72ec\u7acb\u7ebf\u63a7\u5668\uff0c\u5b9e\u6d4b\u5355\u5f00\u53ef\u7a33\u5b9a\u8fd0\u884c<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u2461<\/td>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u5730\u669687.5\u33a1\u5168\u94fa\uff0c3\u697c\u4fdd\u6e29\u597d\u80fd\u8017\u53ef\u63a7<\/td>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u5730\u6696\u65bd\u5de5\u9a8c\u6536\u5355+\u7b2c1\u5e74\u80fd\u8017\u62a5\u544a<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u2462<\/td>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">192mm\u8d85\u8584\u5185\u673a\u4e0d\u538b\u5c42\u9ad8\uff0c\u540a\u9876\u7f8e\u89c2\u534f\u8c03<\/td>\n<td style=\"padding:6px 10px;border-bottom:1px solid #E8ECF0;\">\u5185\u673a\u5b89\u88c5\u540e\u5b9e\u6d4b\u540a\u9876\u9ad8\u5ea6<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:6px 10px;\">\u2463<\/td>\n<td style=\"padding:6px 10px;\">\u63d0\u4f9b\u53cc\u65b9\u6848+20\u5e74\u603b\u8d26\u8f85\u52a9\u51b3\u7b56<\/td>\n<td style=\"padding:6px 10px;\">\u672c\u65b9\u6848\u4e66\u5b8c\u6210\u5373\u4ea4\u4ed8<\/td>\n<\/tr>\n<\/table><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"flip-hint\"><span>\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\uff0c\u67e5\u770b\u300c\u5ba2\u6237\u6210\u529f\u76ee\u6807\u300d<\/span><\/div>\n<\/p><\/div>\n<p>    <!-- \u51b7\u8d1f\u8377\u7ffb\u8f6c\u5361 --><\/p>\n<div class=\"flip-w\">\n<div class=\"load-flip\" >\n<div class=\"flip-i\" style=\"min-height:260px;\">\n<div class=\"flip-f\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:8px;\">\ud83d\udcca \u5404\u623f\u95f4\u51b7\u8d1f\u8377\u5206\u6790\uff08160W\/\u33a1\uff09<\/h4>\n<table class=\"ld-table\">\n<tr>\n<th>\u623f\u95f4<\/th>\n<th>\u9762\u79ef(\u33a1)<\/th>\n<th>\u51b7\u8d1f\u8377(kW)<\/th>\n<th>\u5185\u673a\u578b\u53f7<\/th>\n<th>\u5bb9\u91cf(kW)<\/th>\n<th>\u5197\u4f59<\/th>\n<\/tr>\n<tr>\n<td>\u5ba2\u5385\uff0871+22\u53cc\u673a\uff09<\/td>\n<td>46.0<\/td>\n<td>6.2<\/td>\n<td>71\u578b+22\u578b<\/td>\n<td>7.1+2.2=9.3<\/td>\n<td>\u2705 \u8d85\u914d<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u5367<\/td>\n<td>16.0<\/td>\n<td>2.6<\/td>\n<td>RPIZ-32FSNAQD\/P<\/td>\n<td>3.2<\/td>\n<td>\u2705 +23%<\/td>\n<\/tr>\n<tr>\n<td>\u5973\u513f\u623f<\/td>\n<td>13.5<\/td>\n<td>2.2<\/td>\n<td>RPIZ-25FSNAQD\/P<\/td>\n<td>2.5<\/td>\n<td>\u2705 +14%<\/td>\n<\/tr>\n<tr>\n<td>\u8001\u4eba\u623f<\/td>\n<td>12.0<\/td>\n<td>1.9<\/td>\n<td>RPIZ-22FSNAQD\/P<\/td>\n<td>2.2<\/td>\n<td>\u2705 +16%<\/td>\n<\/tr>\n<tr class=\"total\">\n<td><strong>\u5408\u8ba1<\/strong><\/td>\n<td><strong>87.5<\/strong><\/td>\n<td><strong>12.9<\/strong><\/td>\n<td>\u2014<\/td>\n<td><strong>17.2<\/strong><\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/table>\n<p style=\"font-size:0.72rem;color:#999;margin-top:6px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u5b8c\u6574\u9009\u578b\u5206\u6790<\/p>\n<\/p><\/div>\n<div class=\"flip-b\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:8px;\">\ud83d\udccb \u5b8c\u6574\u51b7\u8d1f\u8377+\u9009\u578b\u5206\u6790\uff08\u80cc\u9762\uff09<\/h4>\n<table class=\"ld-table\">\n<tr>\n<th>\u623f\u95f4<\/th>\n<th>\u9762\u79ef(\u33a1)<\/th>\n<th>\u51b7\u8d1f\u8377(kW)<\/th>\n<th>\u5185\u673a\u578b\u53f7<\/th>\n<th>\u5bb9\u91cf(kW)<\/th>\n<th>\u65b9\u6848A<\/th>\n<th>\u65b9\u6848B<\/th>\n<\/tr>\n<tr>\n<td>\u5ba2\u5385\u4e3b\u533a<\/td>\n<td>46.0<\/td>\n<td>6.2<\/td>\n<td>71\u578b+22\u578b<\/td>\n<td>7.1+2.2<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u5367<\/td>\n<td>16.0<\/td>\n<td>2.6<\/td>\n<td>RPIZ-32FSNAQD\/P<\/td>\n<td>3.2<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<td>\u5973\u513f\u623f<\/td>\n<td>13.5<\/td>\n<td>2.2<\/td>\n<td>RPIZ-25FSNAQD\/P<\/td>\n<td>2.5<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<td>\u8001\u4eba\u623f<\/td>\n<td>12.0<\/td>\n<td>1.9<\/td>\n<td>RPIZ-22FSNAQD\/P<\/td>\n<td>2.2<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr class=\"total\">\n<td><strong>\u5408\u8ba1<\/strong><\/td>\n<td><strong>87.5<\/strong><\/td>\n<td><strong>12.9<\/strong><\/td>\n<td>\u2014<\/td>\n<td><strong>17.2<\/strong><\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/table>\n<div class=\"ld-note\">\u2705 \u8d85\u914d\u7387\u6838\u7b97\uff1a\u5185\u673a\u603b\u5bb9\u91cf17.2kW \u00f7 \u5916\u673a14.0kW = <strong>122.9%<\/strong>\uff0c\u572850%-130%\u5408\u89c4\u533a\u95f4\u5185\uff0c\u4e3a\u7406\u60f3\u914d\u6bd4\u3002<\/div>\n<p>    <!-- \u8d85\u914d\u7387\u901f\u89c8\u4e09\u680f\u5361\uff08P1\uff09 --><\/p>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0;\">\n<div style=\"background:#E8F5E9;border-radius:10px;padding:14px;text-align:center;border:1px solid #C8E6C9;\">\n<div style=\"font-size:1.2rem;font-weight:700;color:#27AE60;\">122.9%<\/div>\n<div style=\"font-size:0.72rem;color:#555;\">\u8d85\u914d\u7387<\/div>\n<div style=\"font-size:0.68rem;color:#888;margin-top:3px;\">\u2705 50%-130%\u5408\u89c4\u00b7\u7406\u60f3\u533a\u95f4<\/div>\n<\/p><\/div>\n<div style=\"background:#E3F2FD;border-radius:10px;padding:14px;text-align:center;border:1px solid #BBDEFB;\">\n<div style=\"font-size:1.2rem;font-weight:700;color:#003A70;\">17.2kW<\/div>\n<div style=\"font-size:0.72rem;color:#555;\">\u5185\u673a\u603b\u5bb9\u91cf<\/div>\n<div style=\"font-size:0.68rem;color:#888;margin-top:3px;\">\u5916\u673a14.0kW\u00b7\u914d\u6bd4\u5408\u7406<\/div>\n<\/p><\/div>\n<div style=\"background:#FFF8E1;border-radius:10px;padding:14px;text-align:center;border:1px solid #FFE082;\">\n<div style=\"font-size:1.2rem;font-weight:700;color:#C8960C;\">~7-9kW<\/div>\n<div style=\"font-size:0.72rem;color:#555;\">\u540c\u5f003\u53f0\u8d1f\u8377<\/div>\n<div style=\"font-size:0.68rem;color:#888;margin-top:3px;\">\u5916\u673a\u5bcc\u4f59\u00b7\u8fd0\u884c\u4ece\u5bb9<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"flip-hint\"><span>\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\uff0c\u67e5\u770b\u5b8c\u6574\u51b7\u8d1f\u8377\u5206\u6790\u8868<\/span><\/div>\n<\/p><\/div>\n<div class=\"confirm-box\">\u3010S1\uff1a\u5ba2\u6237\u6210\u529f\u76ee\u6807\u5df2\u660e\u786e\u3002\u8bf7\u9500\u552e\u786e\u8ba4\u9879\u76ee\u5730\u5740\u3001\u5e38\u4f4f\u4eba\u53e3\u3001\u88c5\u4fee\u9636\u6bb5\u53ca\u8d1f\u8377\u914d\u7f6e\u65e0\u8bef\uff1b\u786e\u8ba4\u540e\u56de\u590d\u300c\u786e\u8ba4\u300d\uff0c\u63a8\u8fdb S2\u3002\u3011<\/div>\n<\/p><\/div>\n<\/div>\n<p><!-- ========================================================== --><br \/>\n<!-- S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad --><br \/>\n<!-- ========================================================== --><\/p>\n<div class=\"section\" id=\"s2\">\n<div class=\"section-inner s2\">\n<div class=\"section-title\">S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/div>\n<div class=\"section-sub\">\u7b2c\u4e8c\u5c42\u601d\u7ef4\u8bca\u65ad \u00b7 \u56db\u5217\u5bf9\u9f50<\/div>\n<p>    <!-- \u56db\u5217\u75db\u70b9\u5361\u7247\u00d74 --><\/p>\n<div class=\"pain-grid\">\n<div class=\"pain-card\">\n<div class=\"pc-head\">\ud83d\udcd0 \u75db\u70b9\u4e00\uff1a\u5c42\u9ad8\u53d7\u9650<\/div>\n<div class=\"pc-body\">\n<div class=\"pc-row\"><span class=\"pc-label\">\u5ba2\u6237\u8bf4<\/span><span class=\"pc-val\">\u5c42\u9ad8\u4e0d\u9ad8\uff0c\u540a\u9876\u4e0d\u80fd\u592a\u539a<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u6280\u672f\u672c\u8d28<\/span><span class=\"pc-val\">\u5185\u673a\u539a\u5ea6\u51b3\u5b9a\u540a\u9876\u9ad8\u5ea6\uff0c\u6807\u51c6\u5185\u673a\u2265250mm<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u8bca\u65ad\u56de\u5e94<\/span><span class=\"pc-val\">\u2705 \u8212\u4eabDC\u5185\u673a\u4ec5192mm\uff0c\u6700\u8584\u7cfb\u5217\u4e4b\u4e00<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u5f15\u7528<\/span><span class=\"pc-val\">\u65e5\u7acb\u8212\u4eab\u4ea7\u54c1\u624b\u518c page_id=1077<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"pain-card\">\n<div class=\"pc-head\">\ud83c\udf2c\ufe0f \u75db\u70b9\u4e8c\uff1a\u6a2a\u5385\u51b7\u70ed\u4e0d\u5747<\/div>\n<div class=\"pc-body\">\n<div class=\"pc-row\"><span class=\"pc-label\">\u5ba2\u6237\u8bf4<\/span><span class=\"pc-val\">\u5ba2\u5385\u6a2a\u5385\u6015\u51b7\u70ed\u4e0d\u5747<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u6280\u672f\u672c\u8d28<\/span><span class=\"pc-val\">46\u33a1\u6a2a\u5385\u5355\u53f0\u5185\u673a\u8986\u76d6\u6709\u9650\uff0c\u8fdc\u7aef\u6e29\u5dee\u5927<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u8bca\u65ad\u56de\u5e94<\/span><span class=\"pc-val\">\u2705 71+22\u53cc\u5185\u673a\u5206\u533a\u9001\u98ce\uff0c\u6bd4\u535571\u578b\u66f4\u5747\u5300<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u5f15\u7528<\/span><span class=\"pc-val\">\u767d\u76ae\u4e66\u00b7\u6c1f\u7cfb\u7edf\u5ba4\u5185\u673a\u9009\u578b\u89c4\u8303<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"pain-card\">\n<div class=\"pc-head\">\ud83d\udcb0 \u75db\u70b9\u4e09\uff1a\u9884\u7b97\u5bf9\u6bd4<\/div>\n<div class=\"pc-body\">\n<div class=\"pc-row\"><span class=\"pc-label\">\u5ba2\u6237\u8bf4<\/span><span class=\"pc-val\">\u4ece\u98ce\u7ba1\u673a\u6539\u4e2d\u592e\u7a7a\u8c03\uff0c\u6015\u8d35<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u6280\u672f\u672c\u8d28<\/span><span class=\"pc-val\">\u4e2d\u592e\u7a7a\u8c03\u521d\u6295\u9ad8\u4f46\u5bff\u547d\u66f4\u957f\u3001\u66f4\u7f8e\u89c2\u3001\u66f4\u9759\u97f3<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u8bca\u65ad\u56de\u5e94<\/span><span class=\"pc-val\">\u26a0\ufe0f \u4e2d\u592e\u7a7a\u8c03\u2248\u00a52.8\u4e07 vs \u98ce\u7ba1\u673a\u2248\u00a51.5\u4e07\uff1b\u4f46\u8212\u4eab\u8d85\u4e00\u7ea7\u80fd\u654820\u5e74\u66f4\u7701<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u5f15\u7528<\/span><span class=\"pc-val\">20\u5e74\u603b\u8d26\u5206\u6790\uff1b\u6307\u4ee40\u4fe1\u4efb\u951a\u70b9<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"pain-card\">\n<div class=\"pc-head\">\ud83d\udd27 \u75db\u70b9\u56db\uff1a\u5916\u673a\u4f4d\u4e0d\u786e\u5b9a<\/div>\n<div class=\"pc-body\">\n<div class=\"pc-row\"><span class=\"pc-label\">\u5ba2\u6237\u8bf4<\/span><span class=\"pc-val\">\u5916\u673a\u4f4d\u4e0d\u77e5\u9053\u591f\u4e0d\u591f\u5bbd<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u6280\u672f\u672c\u8d28<\/span><span class=\"pc-val\">\u5355\u98ce\u6247770mm vs \u53cc\u98ce\u62471380mm\uff0c\u5bbd\u5dee610mm<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u8bca\u65ad\u56de\u5e94<\/span><span class=\"pc-val\">\ud83d\udd34 \u5173\u952e\u51b3\u7b56\u70b9\uff01\u22651380mm\u2192\u53cc\u98ce\u6247\uff1b<1380\u2192\u5355\u98ce\u6247<\/span><\/div>\n<div class=\"pc-row\"><span class=\"pc-label\">\u5f15\u7528<\/span><span class=\"pc-val\">\u5f85\u73b0\u573a\u52d8\u6d4b\u786e\u8ba4\u5916\u673a\u4f4d\u5c3a\u5bf8\u540e\u9009\u5b9a<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u5de5\u7a0b\u7ea2\u7ebf\u00d73 --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:18px 0 8px;\">\ud83d\udeab \u5de5\u7a0b\u7ea2\u7ebf\u63d0\u9192<\/h4>\n<div class=\"redline-grid\">\n<div class=\"redline-card\">\n<div class=\"rl-title\">\u8d85\u914d\u7387\u7ea2\u7ebf<\/div>\n<div class=\"rl-desc\">\u6c1f\u7cfb\u7edf\u8fde\u63a5\u7387\u4e25\u683c\u63a7\u5236\u572850%-130%\u4e4b\u95f4\u3002\u672c\u65b9\u6848\u8d85\u914d\u7387122.9%\uff0c\u5904\u4e8e\u7406\u60f3\u533a\u95f4\u3002<\/div>\n<\/p><\/div>\n<div class=\"redline-card\">\n<div class=\"rl-title\">\u5b89\u88c5\u95f4\u8ddd\u7ea2\u7ebf<\/div>\n<div class=\"rl-desc\">\u94dc\u7ba1\u5f2f\u7ba1\u534a\u5f84\u2265\u7ba1\u5f843.5\u500d\uff1b\u5206\u6b67\u7ba1\u524d\u540e\u76f4\u7ba1\u22650.5m\uff1b\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22651%\u3002<\/div>\n<\/p><\/div>\n<div class=\"redline-card\">\n<div class=\"rl-title\">\u4fdd\u538b\u7ea2\u7ebf<\/div>\n<div class=\"rl-desc\">R410A\u7cfb\u7edf\u4fdd\u538b4.15MPa\u3001\u4fdd\u538b24h\u3001\u538b\u964d\u22640.02MPa\u3002\u4e0d\u5408\u683c\u4e0d\u5f97\u8fdb\u5165\u4e0b\u4e00\u5de5\u5e8f\u3002<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u9690\u6027\u7269\u7406\u7ea6\u675f --><\/p>\n<div class=\"info-box caution\">\n      <strong>\u26a0\ufe0f \u9690\u6027\u7269\u7406\u7ea6\u675f\uff08\u5f85\u73b0\u573a\u786e\u8ba4\uff09\uff1a<\/strong><br \/>\n      \u2460 \u5916\u673a\u4f4d\u5bbd\u5ea6\u22651380mm\u2192\u9009\u53cc\u98ce\u6247B\uff1b<1380\u2192\u9009\u5355\u98ce\u6247A<br \/>\n      \u2461 \u662f\u5426\u6709\u897f\u6652\/\u5927\u9762\u79ef\u73bb\u7483\u2192\u9700\u52a0\u5927\u5ba2\u5385\u5236\u51b7\u91cf<br \/>\n      \u2462 \u5730\u669687.5\u33a1\u662f\u5426\u5168\u94fa\uff0c\u53a8\u623f\/\u9633\u53f0\u662f\u5426\u94fa\u8bbe<br \/>\n      \u2463 \u5c42\u9ad8\u5b9e\u6d4b\u6570\u636e\u5f71\u54cd\u540a\u9876\u53ca\u5185\u673a\u5b89\u88c5\u4f4d\u7f6e<br \/>\n      \u2464 \u83f2\u65af\u66fc\u51b7\u51dd\u7089\u9700\u5ba4\u5916\u6392\u70df\u53e3\uff0c3\u697c\u6761\u4ef6\u901a\u5e38\u826f\u597d\n    <\/div>\n<p>    <!-- \u4fe1\u4efb\u951a\u70b9 --><\/p>\n<div class=\"info-box trust\">\n      <strong>\ud83d\udca1 \u4fe1\u4efb\u951a\u70b9\uff1a<\/strong> \u672c\u65b9\u6848\u63d0\u4f9b2\u79cd\u7a7a\u8c03\u65b9\u6848\u00d73\u6863\u5730\u6696\u00d73\u6b3e\u9505\u7089\u7684\u900f\u660e\u7ec4\u5408\u4ef7\u683c\u3002\u82e5\u9884\u7b97\u6781\u5ea6\u7d27\u5f20\uff0c\u53ef\u4ec5\u505a\u4e2d\u592e\u7a7a\u8c03\u6682\u7f13\u5730\u6696\u3002<br \/>\n      <span style=\"font-size:0.74rem;color:#888;\">\u4ef7\u683c\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a2026\u5e74V5.0\u4ef7\u683c\u6307\u4ee4\u5e93\uff08page_id=662\uff09<\/span>\n    <\/div>\n<div class=\"confirm-box\">\u3010S2\uff1a\u9700\u6c42\u75db\u70b9\u5df2\u8bca\u65ad\u3002\u8bf7\u786e\u8ba4\u56db\u5217\u5bf9\u9f50\u8868\u53ca\u9690\u6027\u7ea6\u675f\u65e0\u8bef\uff1b\u786e\u8ba4\u540e\u56de\u590d\u300c\u786e\u8ba4\u300d\uff0c\u63a8\u8fdb S3\u3002\u3011<\/div>\n<\/p><\/div>\n<\/div>\n<p><!-- ========================================================== --><br \/>\n<!-- S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4 --><br \/>\n<!-- ========================================================== --><\/p>\n<div class=\"section\" id=\"s3\">\n<div class=\"section-inner s3\">\n<div class=\"section-title\">S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u6210\u672c\u5bf9\u6bd4<\/div>\n<div class=\"section-sub\">\u539f\u59cb\u60f3\u6cd5 vs \u6027\u4ef7\u6bd4\u63a8\u8350 vs 20\u5e74\u957f\u6548\u4f18\u9009 \u00b7 \u5730\u6696\u4e09\u6863 \u00b7 20\u5e74\u603b\u8d26<\/div>\n<p>    <!-- \ud83e\udded \u9009\u62e9\u8def\u5f84\uff08\u65b9\u6848\u2462\u8981\u6c42\uff09 --><\/p>\n<div class=\"info-box caution\" style=\"margin:10px 0 16px;font-size:0.82rem;\">\n      <strong>\ud83e\udded \u65b9\u6848\u9009\u62e9\u8def\u5f84\uff1a\u5148\u5b9a\u7a7a\u8c03\uff08\u5355\u98ce\u6247\/\u53cc\u98ce\u6247\uff09\u2192 \u518d\u9009\u58c1\u6302\u7089\uff08\u83f2\u65af\u66fc\/\u535a\u4e16\/\u6797\u5185\uff09\u2192 \u6700\u540e\u5b9a\u5730\u6696\u6863\u4f4d\uff08\u7ecf\u6d4e\/\u6807\u51c6\/\u8212\u9002\uff09<\/strong><br \/>\n      <span style=\"color:#666;\">\u2022 \u7a7a\u8c03\uff1a\u5916\u673a\u4f4d\u22651380mm\u9009<strong>\u53cc\u98ce\u6247<\/strong>\uff08\u566a\u97f3\u4f4e2dB\u00b7\u98ce\u91cf\u592717%\uff09\uff0c\uff1c1380mm\u9009<strong>\u5355\u98ce\u6247<\/strong><br \/>\n      \u2022 \u58c1\u6302\u7089\uff1a\u63a8\u8350\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\uff08\u4e00\u7ea7\u80fd\u6548\u2265106%\u00b7WiFi\u667a\u63a7\uff09<br \/>\n      \u2022 \u5730\u6696\uff1a\u9884\u7b97\u4f18\u5148\u9009\u7ecf\u6d4e\u6863\uff0c\u6027\u4ef7\u6bd4\u9009<strong>\u6807\u51c6\u6863<\/strong>\uff08\u63a8\u8350\uff09\uff0c\u957f\u671f\u81ea\u4f4f\u9009\u8212\u9002\u6863<\/span>\n    <\/div>\n<p>    <!-- \u7a7a\u8c03\u4e09\u65b9\u6848\u7ffb\u8f6c\u5361 --><\/p>\n<h4 style=\"font-size:0.95rem;color:#003A70;margin-bottom:8px;\">\u2744\ufe0f \u7a7a\u8c03\u4e09\u65b9\u6848 \u00b7 \u539f\u59cb\u60f3\u6cd5 vs \u6027\u4ef7\u6bd4\u63a8\u8350 vs 20\u5e74\u957f\u6548\u4f18\u9009<\/h4>\n<p style=\"font-size:0.78rem;color:#888;margin-bottom:10px;\">\u4e09\u5957\u65b9\u6848\u8986\u76d6\u7ecf\u6d4e\u578b\u2192\u5747\u8861\u578b\u2192\u8212\u9002\u578b\uff0c\u6309\u9884\u7b97\u548c\u9700\u6c42\u81ea\u7531\u9009\u62e9\u3002<\/p>\n<div class=\"sf-grid\">\n      <!-- \u65b9\u6848A \u5355\u98ce\u6247 --><\/p>\n<div class=\"sf-card\" >\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u65b9\u6848\u4e00\u00b7\u539f\u59cb\u60f3\u6cd5\u00b7\u5b89\u88c5\u5e73\u9762\u793a\u610f\"><svg viewBox=\"0 0 240 140\" style=\"width:100%;height:100%;background:#F0F4F8;\">\n  <rect x=\"10\" y=\"10\" width=\"220\" height=\"120\" rx=\"6\" fill=\"none\" stroke=\"#003A70\" stroke-width=\"1.5\"\/>\n  <rect x=\"30\" y=\"25\" width=\"55\" height=\"35\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"57\" y=\"47\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u5ba2\u538571\u578b<\/text>\n  <rect x=\"155\" y=\"25\" width=\"55\" height=\"35\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"182\" y=\"47\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u9910\u538556\u578b<\/text>\n  <rect x=\"30\" y=\"85\" width=\"40\" height=\"30\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"50\" y=\"103\" font-size=\"6\" fill=\"#2980b9\" text-anchor=\"middle\">\u4e3b\u536732\u578b<\/text>\n  <rect x=\"92\" y=\"85\" width=\"35\" height=\"30\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"109\" y=\"103\" font-size=\"6\" fill=\"#2980b9\" text-anchor=\"middle\">\u6b21\u536725\u578b<\/text>\n  <rect x=\"150\" y=\"85\" width=\"35\" height=\"30\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"167\" y=\"103\" font-size=\"6\" fill=\"#2980b9\" text-anchor=\"middle\">\u4e66\u623f22\u578b<\/text>\n  <line x1=\"57\" y1=\"60\" x2=\"57\" y2=\"85\" stroke=\"#c0392b\" stroke-width=\"1\" stroke-dasharray=\"3,2\"\/>\n  <line x1=\"182\" y1=\"60\" x2=\"182\" y2=\"85\" stroke=\"#c0392b\" stroke-width=\"1\" stroke-dasharray=\"3,2\"\/>\n  <text x=\"10\" y=\"138\" font-size=\"6\" fill=\"#888\">\u5b89\u88c5\u5e73\u9762\u793a\u610f \u00b7 5\u53f0\u5185\u673a\u5e03\u5c40<\/text>\n<\/svg><\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u65b9\u6848\u4e00 \u00b7 \u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848<\/div>\n<div class=\"sf-price\">\u00a528,521<\/div>\n<div class=\"sf-model\">RAS-140HRNAQ \u00b7 14.0kW<\/div>\n<div class=\"sf-tags\"><span>APF 5.45<\/span><span>54dB<\/span><span>\u8d85\u4e00\u7ea7\u80fd\u6548<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u62a5\u4ef7<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th colspan=\"2\">\u65b9\u6848\u4e00 \u00b7 \u539f\u59cb\u60f3\u6cd5 \u00b7 \u62a5\u4ef7\u660e\u7ec6<\/th>\n<\/tr>\n<tr>\n<td>\u5916\u673aRAS-140HRNAQ<\/td>\n<td>\u9762\u4ef7\u00a512,875 \u2192 8\u6298<strong>\u00a510,300<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a(71+22+32+25+22)8\u6298<\/td>\n<td><strong>\u00a512,550<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u5907\u5c0f\u8ba1(8\u6298\u540e)<\/td>\n<td><strong>\u00a522,850<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u8d39(\u5916\u673a\u00a5600+5\u5185\u673a\u00d7\u00a51,600)<\/td>\n<td>\u00a58,600<\/td>\n<\/tr>\n<tr>\n<td>WiFi\u7ebf\u63a7\u5668\u00d75<\/td>\n<td>\u00a51,000<\/td>\n<\/tr>\n<tr>\n<td>\u56fd\u8865+\u54c1\u724c\u6708\u5382\u8865-500+\u6298\u4e0a\u6298+\u4f1a\u5458<\/td>\n<td>\u2212\u00a54,128<\/td>\n<\/tr>\n<\/table>\n<div class=\"bt-total\"><span>\u7a7a\u8c03\u5b9e\u4ed8(\u542b\u4f1a\u5458)<\/span><span>\u00a528,521<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>      <!-- \u65b9\u6848B \u53cc\u98ce\u6247\uff08\u63a8\u8350\uff09 --><\/p>\n<div class=\"sf-card\" >\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u65b9\u6848\u4e8c\u00b7\u6027\u4ef7\u6bd4\u63a8\u8350\u00b7\u5b89\u88c5\u5e73\u9762\u793a\u610f\"><svg viewBox=\"0 0 240 140\" style=\"width:100%;height:100%;background:#F0F4F8;\"><rect x=\"10\" y=\"10\" width=\"220\" height=\"120\" rx=\"6\" fill=\"none\" stroke=\"#003A70\" stroke-width=\"1.5\"\/><rect x=\"30\" y=\"25\" width=\"55\" height=\"35\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/><text x=\"57\" y=\"47\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u5ba2\u538571\u578b<\/text><rect x=\"155\" y=\"25\" width=\"55\" height=\"35\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/><text x=\"182\" y=\"47\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u9910\u538556\u578b<\/text><rect x=\"30\" y=\"85\" width=\"40\" height=\"30\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/><text x=\"50\" y=\"103\" font-size=\"6\" fill=\"#2980b9\" text-anchor=\"middle\">\u4e3b\u536732\u578b<\/text><rect x=\"92\" y=\"85\" width=\"35\" height=\"30\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/><text x=\"109\" y=\"103\" font-size=\"6\" fill=\"#2980b9\" text-anchor=\"middle\">\u6b21\u536725\u578b<\/text><rect x=\"150\" y=\"85\" width=\"35\" height=\"30\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/><text x=\"167\" y=\"103\" font-size=\"6\" fill=\"#2980b9\" text-anchor=\"middle\">\u4e66\u623f22\u578b<\/text><line x1=\"57\" y1=\"60\" x2=\"57\" y2=\"85\" stroke=\"#c0392b\" stroke-width=\"1\" stroke-dasharray=\"3,2\"\/><line x1=\"182\" y1=\"60\" x2=\"182\" y2=\"85\" stroke=\"#c0392b\" stroke-width=\"1\" stroke-dasharray=\"3,2\"\/><text x=\"10\" y=\"138\" font-size=\"6\" fill=\"#888\">\u5b89\u88c5\u5e73\u9762\u793a\u610f \u00b7 5\u53f0\u5185\u673a\u5e03\u5c40<\/text><\/svg><\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u65b9\u6848\u4e8c \u00b7 \u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848 \u2605<\/div>\n<div class=\"sf-price\">\u00a530,083<\/div>\n<div class=\"sf-model\">RAS-140HRNBQ \u00b7 14.0kW<\/div>\n<div class=\"sf-tags\"><span>APF 5.4<\/span><span>52dB<\/span><span>\u98ce\u91cf\u592717%<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u62a5\u4ef7<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th colspan=\"2\">\u65b9\u6848\u4e8c \u00b7 \u6027\u4ef7\u6bd4\u63a8\u8350 \u00b7 \u62a5\u4ef7\u660e\u7ec6<\/th>\n<\/tr>\n<tr>\n<td>\u5916\u673aRAS-140HRNBQ<\/td>\n<td>\u9762\u4ef7\u00a515,063 \u2192 8\u6298<strong>\u00a512,050<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a(71+22+32+25+22)8\u6298<\/td>\n<td><strong>\u00a512,550<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u5907\u5c0f\u8ba1(8\u6298\u540e)<\/td>\n<td><strong>\u00a524,600<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u8d39(\u5916\u673a\u00a5600+5\u5185\u673a\u00d7\u00a51,600)<\/td>\n<td>\u00a58,600<\/td>\n<\/tr>\n<tr>\n<td>WiFi\u7ebf\u63a7\u5668\u00d75<\/td>\n<td>\u00a51,000<\/td>\n<\/tr>\n<tr>\n<td>\u4f18\u60e0\u5408\u8ba1(\u56fd\u8865-1,500+\u54c1\u724c\u6708\u5382\u8865-600+\u6298\u4e0a\u6298-1,216+\u4f1a\u5458-1,000)<\/td>\n<td>\u2212\u00a54,316<\/td>\n<\/tr>\n<\/table>\n<div class=\"bt-total\"><span>\u7a7a\u8c03\u5b9e\u4ed8(\u542b\u4f1a\u5458\u00a5199)<\/span><span>\u00a530,083<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>      <!-- \u58c1\u6302\u7089\u4e09\u9009\uff08\u7b2c\u4e09\u4e2a\u4f4d\u7f6e\u5c55\u793a\u9505\u7089\u9009\u9879\uff09 --><\/p>\n<div class=\"sf-card\" >\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u83f2\u65af\u66fc\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-fsmbgl-a1je-waiguan.jpg\" alt=\"\u83f2\u65af\u66fc\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\" loading=\"lazy\"><\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u58c1\u6302\u7089\u4e09\u9009<\/div>\n<div class=\"sf-price\">\u00a513,597\u8d77<\/div>\n<div class=\"sf-model\">\u83f2\u65af\u66fc\/\u535a\u4e16\/\u6797\u5185<\/div>\n<div class=\"sf-tags\"><span>\u51b7\u51dd\u7089<\/span><span>\u4e00\u7ea7\u80fd\u6548<\/span><span>\u4e09\u5927\u54c1\u724c<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u5bf9\u6bd4<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th>\u54c1\u724c<\/th>\n<th>\u578b\u53f7<\/th>\n<th>\u4ef7\u683c<\/th>\n<\/tr>\n<tr>\n<td style=\"font-weight:600;\">\ud83d\udd25 \u83f2\u65af\u66fc\uff08\u63a8\u8350\uff09<\/td>\n<td>B1JG 25kW\u51b7\u51dd<\/td>\n<td style=\"font-weight:700;color:#E87A2A;\">\u00a513,597\uff08\u542b\u5b89\u88c5\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u535a\u4e16<\/td>\n<td>\u8ffd\u5149G6100W 24kW\u51b7\u51dd<\/td>\n<td>\u8be6\u8be2\u987e\u95ee<\/td>\n<\/tr>\n<tr>\n<td>\u6797\u5185<\/td>\n<td>G58 26kW\u51b7\u51dd<\/td>\n<td>\u8be6\u8be2\u987e\u95ee<\/td>\n<\/tr>\n<tr>\n<td>\u80fd\u6548<\/td>\n<td colspan=\"2\">\u4e00\u7ea7\u51b7\u51dd \u2265106%<\/td>\n<\/tr>\n<tr>\n<td>\u4ea7\u5730<\/td>\n<td colspan=\"2\">\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td>\u8d28\u4fdd<\/td>\n<td colspan=\"2\">5\u5e74\u6574\u673a<\/td>\n<\/tr>\n<tr>\n<td>\u529f\u80fd<\/td>\n<td colspan=\"2\">WiFi\u667a\u63a7 + \u751f\u6d3b\u70ed\u6c34<\/td>\n<\/tr>\n<\/table>\n<div class=\"bt-total\"><span>\u63a8\u8350\uff1a\u83f2\u65af\u66fcB1JG<\/span><span>WiFi\u667a\u80fd\u63a7\u5236<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u65b9\u6848\u2462 \u8212\u4eab125\u4e00\u62d6\u56db\uff08\u65b0\u589e\uff09 --><\/p>\n<div class=\"sf-grid\" style=\"margin-top:0;\">\n<div class=\"sf-card\">\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u65b9\u6848\u4e09\u00b720\u5e74\u957f\u6548\u4f18\u9009\u00b7\u5b89\u88c5\u5e73\u9762\u793a\u610f\"><svg viewBox=\"0 0 240 140\" style=\"width:100%;height:100%;background:#F0F4F8;\">\n  <rect x=\"10\" y=\"10\" width=\"220\" height=\"120\" rx=\"6\" fill=\"none\" stroke=\"#003A70\" stroke-width=\"1.5\"\/>\n  <rect x=\"35\" y=\"25\" width=\"60\" height=\"38\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"65\" y=\"49\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u5ba2\u538571\u578b<\/text>\n  <rect x=\"160\" y=\"25\" width=\"50\" height=\"38\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"185\" y=\"49\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u4e3b\u536732\u578b<\/text>\n  <rect x=\"35\" y=\"85\" width=\"50\" height=\"35\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"60\" y=\"105\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u6b21\u536725\u578b<\/text>\n  <rect x=\"160\" y=\"85\" width=\"50\" height=\"35\" rx=\"3\" fill=\"#E8F0FE\" stroke=\"#2980b9\" stroke-width=\"1\"\/>\n  <text x=\"185\" y=\"105\" font-size=\"7\" fill=\"#2980b9\" text-anchor=\"middle\">\u4e66\u623f22\u578b<\/text>\n  <text x=\"10\" y=\"138\" font-size=\"6\" fill=\"#888\">\u5b89\u88c5\u5e73\u9762\u793a\u610f \u00b7 4\u53f0\u5185\u673a\u5e03\u5c40 \u00b7 \u7ecf\u6d4e\u578b<\/text>\n<\/svg><\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u65b9\u6848\u4e09 \u00b7 20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848<\/div>\n<div class=\"sf-price\">\u00a526,510<\/div>\n<div class=\"sf-model\">RAS-125HRNAQ \u00b7 12.5kW \u00b7 \u4e00\u62d6\u56db<\/div>\n<div class=\"sf-tags\"><span>APF 5.5<\/span><span>54dB<\/span><span>\u8d85\u4e00\u7ea7\u80fd\u6548<\/span><span>\u7ecf\u6d4e\u578b<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u62a5\u4ef7<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u91d1\u989d<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<tr>\n<td>\u4e3b\u673aRAS-125HRNAQ<\/td>\n<td>\u00a59,330<\/td>\n<td>8\u6298<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a71\u578b<\/td>\n<td>\u00a52,810<\/td>\n<td>\u5ba2\u5385<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a32\u578b<\/td>\n<td>\u00a52,480<\/td>\n<td>\u4e3b\u5367<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a25\u578b<\/td>\n<td>\u00a52,440<\/td>\n<td>\u5973\u513f\u623f<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a22\u578b<\/td>\n<td>\u00a52,410<\/td>\n<td>\u8001\u4eba\u623f<\/td>\n<\/tr>\n<tr>\n<td>WiFi\u7ebf\u63a7\u5668\u00d74<\/td>\n<td>\u00a5640<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u8d39\u00d74<\/td>\n<td>\u00a56,400<\/td>\n<td>\u00a51,600\/\u53f0<\/td>\n<\/tr>\n<tr style=\"background:#FFF8E1;\">\n<td><strong>\u7a7a\u8c03\u603b\u4ef7<\/strong><\/td>\n<td><strong>\u2248\u00a526,510<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<\/table><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>      <!-- \u5360\u4f4d\uff0c\u4fdd\u63013\u5217 --><\/p>\n<div style=\"visibility:hidden;\"><\/div>\n<div style=\"visibility:hidden;\"><\/div>\n<\/p><\/div>\n<p>    <!-- \u7a7a\u8c03\u53c2\u6570\u5bf9\u6bd4\u8868 --><\/p>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:16px 0 6px;\">\ud83d\udcca \u65b9\u6848\u6a2a\u5411\u5bf9\u6bd4\u8868<\/h4>\n<table class=\"comp-table\">\n<tr>\n<th>\u5bf9\u6bd4\u9879<\/th>\n<th>\u65b9\u6848\u4e00 \u00b7 \u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848<\/th>\n<th>\u65b9\u6848\u4e8c \u00b7 \u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848 \u2605<\/th>\n<th>\ud83d\udfe2 \u65b9\u6848\u4e09 \u00b7 20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848<\/th>\n<\/tr>\n<tr>\n<td>\u4e00\u62d6\u51e0<\/td>\n<td>\u4e00\u62d6\u4e94<\/td>\n<td>\u4e00\u62d6\u4e94<\/td>\n<td>\u4e00\u62d6\u56db<\/td>\n<\/tr>\n<tr>\n<td>\u5ba2\u5385\u914d\u7f6e<\/td>\n<td>71+22\u53cc\u673a<\/td>\n<td>71+22\u53cc\u673a<\/td>\n<td>71\u5355\u673a<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u51b7\u91cf<\/td>\n<td>17.2kW<\/td>\n<td>17.2kW<\/td>\n<td>15.0kW<\/td>\n<\/tr>\n<tr>\n<td>\u8d85\u914d\u7387<\/td>\n<td>122.9%<\/td>\n<td>122.9%<\/td>\n<td>120% \u2705<\/td>\n<\/tr>\n<tr>\n<td>\u5916\u673a\u5c3a\u5bf8<\/td>\n<td>770\u00d7980\u00d7360mm<\/td>\n<td>1380\u00d7950\u00d7320mm<\/td>\n<td>770\u00d7980\u00d7360mm<\/td>\n<\/tr>\n<tr>\n<td>\u566a\u97f3<\/td>\n<td>54dB(A)<\/td>\n<td>52dB(A)<\/td>\n<td>54dB(A)<\/td>\n<\/tr>\n<tr>\n<td>APF<\/td>\n<td>5.45<\/td>\n<td>5.40<\/td>\n<td>5.50<\/td>\n<\/tr>\n<tr style=\"background:#FFF8E1;\">\n<td><strong>\u7a7a\u8c03\u603b\u4ef7<\/strong><\/td>\n<td><strong>\u00a528,521<\/strong><\/td>\n<td class=\"hl\"><strong>\u00a530,083<\/strong><\/td>\n<td><strong>\u00a526,510<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u4f4d<\/td>\n<td>\u5747\u8861\u578b<\/td>\n<td>\u8212\u9002\u578b<\/td>\n<td>\u7ecf\u6d4e\u578b<\/td>\n<\/tr>\n<\/table>\n<tr>\n<td>\u98ce\u91cf<\/td>\n<td>\u6807\u51c6<\/td>\n<td>+17%<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u5b9e\u4ed8<\/td>\n<td>\u00a528,521<\/td>\n<td>\u00a530,083<\/td>\n<\/tr>\n<tr>\n<td>\u5dee\u4ef7<\/td>\n<td>\u2014<\/td>\n<td>+\u00a51,662<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u6761\u4ef6<\/td>\n<td>\u5916\u673a\u4f4d\u5bbd\u5ea6<1380mm<\/td>\n<td>\u5916\u673a\u4f4d\u5bbd\u5ea6\u22651380mm \u2705\u63a8\u8350<\/td>\n<\/tr>\n<tr class=\"disclosure\">\n<td colspan=\"3\">\u26a0\ufe0f \u52a3\u52bf\u62ab\u9732\uff1a\u5355\u98ce\u6247\u6781\u7aef\u9ad8\u6e29\u6563\u70ed\u7565\u5f31\uff1b\u53cc\u98ce\u6247\u9700\u8f83\u5bbd\u5916\u673a\u4f4d(\u22651380mm)<\/td>\n<\/tr>\n<\/table>\n<p>    <!-- \ud83d\udd25 \u5730\u6696\u4e09\u6863\u7ffb\u8f6c\u5361\uff08\u7c7b\u578b4\uff1a\u5730\u6696\u5bf9\u6bd4\u5361\u00d73\uff09 --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:18px 0 6px;\">\ud83d\udd25 \u5730\u6696\u7cfb\u7edf \u00b7 \u4e09\u6863\u4f4d\uff08\u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\u67e5\u770b\u660e\u7ec6\uff09<\/h4>\n<div class=\"sf-grid\">\n      <!-- \u7ecf\u6d4e\u6863 --><\/p>\n<div class=\"sf-card\" >\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u5730\u6696\u7ecf\u6d4e\u6863\u4f1f\u661f\u603b\u63a7\u914d\u7f6e\u56fe\">\ud83d\udcb0<\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u7ecf\u6d4e\u6863 \u00b7 \u4f1f\u661f\u603b\u63a7<\/div>\n<div class=\"sf-price\">\u00a5125\/\u33a1 \u00b7 \u5171\u00a510,938<\/div>\n<div class=\"sf-model\">\u7ba125-16 \u00b7 \u4f1f\u661f\u603b\u63a7<\/div>\n<div class=\"sf-tags\"><span>\u9884\u7b97\u4f18\u5148<\/span><span>\u57fa\u7840\u5957\u9910<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u914d\u7f6e<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th colspan=\"2\">\u7ecf\u6d4e\u6863 \u00b7 \u5730\u6696\u914d\u7f6e<\/th>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u9762\u79ef<\/td>\n<td>87.5\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u5355\u4ef7<\/td>\n<td>\u00a5125\/\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u94fa\u8bbe\u8d39<\/td>\n<td>\u00a510,938<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u6750<\/td>\n<td>\u7ba125-16 \u00b7 \u4f1f\u661f<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u65b9\u5f0f<\/td>\n<td>\u4f1f\u661f\u603b\u63a7\uff08\u5168\u5c4b\u7edf\u4e00\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4f18\u52bf<\/td>\n<td>\u521d\u6295\u6700\u4f4e\uff0c\u6ee1\u8db3\u57fa\u672c\u91c7\u6696<\/td>\n<\/tr>\n<tr>\n<td>\u52a3\u52bf<\/td>\n<td>\u65e0\u5206\u5ba4\u6e29\u63a7\uff0c\u65e0\u6cd5\u6309\u623f\u95f4\u8c03\u8282<\/td>\n<\/tr>\n<\/table>\n<div class=\"bt-total\"><span>\u7ecf\u6d4e\u6863\u603b\u4ef7<\/span><span>\u00a510,938<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>      <!-- \u6807\u51c6\u6863\uff08\u63a8\u8350\uff09 --><\/p>\n<div class=\"sf-card\" >\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u5730\u6696\u6807\u51c6\u6863\u66fc\u745e\u5fb7\u5206\u63a7\u914d\u7f6e\u56fe\">\u2705<\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u6807\u51c6\u6863 \u00b7 \u66fc\u745e\u5fb7\u5206\u63a7 \u2605<\/div>\n<div class=\"sf-price\">\u00a5145\/\u33a1 \u00b7 \u5171\u00a512,688<\/div>\n<div class=\"sf-model\">\u7ba125-16 \u00b7 \u66fc\u745e\u5fb7\u5206\u63a7<\/div>\n<div class=\"sf-tags\"><span>\u2b50 \u6027\u4ef7\u6bd4\u4e4b\u9009<\/span><span>\u5206\u5c42\u63a7\u6e29<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u914d\u7f6e<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th colspan=\"2\">\u6807\u51c6\u6863 \u00b7 \u5730\u6696\u914d\u7f6e\uff08\u63a8\u8350\uff09<\/th>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u9762\u79ef<\/td>\n<td>87.5\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u5355\u4ef7<\/td>\n<td>\u00a5145\/\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u94fa\u8bbe\u8d39<\/td>\n<td>\u00a512,688<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u6750<\/td>\n<td>\u7ba125-16 \u00b7 \u4f1f\u661f<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u65b9\u5f0f<\/td>\n<td>\u66fc\u745e\u5fb7\u5206\u63a7 \u00b7 \u5206\u5c42\u63a7\u6e29<\/td>\n<\/tr>\n<tr>\n<td>\u4f18\u52bf<\/td>\n<td>\u5206\u5ba4\u72ec\u7acb\u8c03\u8282\uff0c\u6027\u4ef7\u6bd4\u6700\u4f18<\/td>\n<\/tr>\n<tr>\n<td>\u52a3\u52bf<\/td>\n<td>\u6bd4\u7ecf\u6d4e\u6863\u591a\u00a51,750<\/td>\n<\/tr>\n<\/table>\n<div class=\"bt-total\"><span>\u6807\u51c6\u6863\u603b\u4ef7<\/span><span>\u00a512,688<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>      <!-- \u8212\u9002\u6863 --><\/p>\n<div class=\"sf-card\" >\n<div class=\"sf-inner\">\n<div class=\"sf-front\">\n<div class=\"sf-img\" aria-label=\"\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\">\ud83d\udd25<\/div>\n<div class=\"sf-info\">\n<div class=\"sf-name\">\u8212\u9002\u6863 \u00b7 \u8282\u80fd\u8bbe\u8ba1<\/div>\n<div class=\"sf-price\">\u00a5179\/\u33a1 \u00b7 \u5171\u00a515,663<\/div>\n<div class=\"sf-model\">\u7ba132-20 \u00b7 WiFi\u8054\u52a8<\/div>\n<div class=\"sf-tags\"><span>\u8212\u9002\u4f18\u5148<\/span><span>\u8282\u80fd\u957f\u8fdc<\/span><span>\u6d41\u91cf+100%<\/span><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u914d\u7f6e<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"sf-back\">\n<table class=\"bt\">\n<tr>\n<th colspan=\"2\">\u8212\u9002\u6863 \u00b7 \u5730\u6696\u914d\u7f6e<\/th>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u9762\u79ef<\/td>\n<td>87.5\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u5355\u4ef7<\/td>\n<td>\u00a5179\/\u33a1<\/td>\n<\/tr>\n<tr>\n<td>\u94fa\u8bbe\u8d39<\/td>\n<td>\u00a515,663<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u6750<\/td>\n<td>\u7ba132-20 \u00b7 \u6d41\u91cf+100%<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u65b9\u5f0f<\/td>\n<td>\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236+WiFi\u8fdc\u7a0b<\/td>\n<\/tr>\n<tr>\n<td>\u4f18\u52bf<\/td>\n<td>\u70ed\u6c34\u5faa\u73af\u5747\u5300\uff0c\u957f\u671f\u8282\u80fd\u7ea650%<\/td>\n<\/tr>\n<tr>\n<td>\u52a3\u52bf<\/td>\n<td>\u521d\u6295\u6700\u9ad8\uff0c\u6bd4\u6807\u51c6\u6863\u591a\u00a52,975<\/td>\n<\/tr>\n<\/table>\n<div class=\"bt-total\"><span>\u8212\u9002\u6863\u603b\u4ef7<\/span><span>\u00a515,663<\/span><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u63a8\u8350\u7ec4\u5408\u62a5\u4ef7 --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:18px 0 6px;\">\u2605 \u63a8\u8350\u7ec4\u5408 \u00b7 \u5168\u5c4b\u62a5\u4ef7\u660e\u7ec6<\/h4>\n<p style=\"font-size:0.78rem;color:#888;margin-bottom:8px;\">\u63a8\u8350\uff1a\u65b9\u6848\u4e8c\u4e00\u62d6\u4e94 + \u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089 + \u6807\u51c6\u6863\u5730\u6696<\/p>\n<table class=\"comp-table\">\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u91d1\u989d<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u00b7\u8bbe\u5907\u6298\u540e\u4ef7<\/td>\n<td>\u00a524,320<\/td>\n<td>\u8212\u4eab8\u6298\uff08\u5916\u673a\u00a512,050+\u5185\u673a\u00a512,270\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u00b7\u5b89\u88c5\u8d39<\/td>\n<td>\u00a58,600<\/td>\n<td>\u5916\u673a\u00a5600+5\u5185\u673a\u00d7\u00a51,600<\/td>\n<\/tr>\n<tr>\n<td>WiFi\u7ebf\u63a7\u5668\u00d75<\/td>\n<td>\u00a51,000<\/td>\n<td>PC-P1HVQA<\/td>\n<\/tr>\n<tr>\n<td>\u4f18\u60e0\u5408\u8ba1<\/td>\n<td>\u2212\u00a54,316<\/td>\n<td>\u56fd\u8865-1,500+\u54c1\u724c\u6708\u5382\u8865-600+\u6298\u4e0a\u6298-1,216+\u4f1a\u5458-1,000<\/td>\n<\/tr>\n<tr>\n<td style=\"font-weight:700;\">\u7a7a\u8c03\u5230\u624b\u4ef7<\/td>\n<td style=\"font-weight:700;\">\u00a530,083<\/td>\n<td>\u542b\u4f1a\u5458\u8d39\u00a5199<\/td>\n<\/tr>\n<tr>\n<td>\u83f2\u65af\u66fcB1JG 25kW\uff08\u542b\u5b89\u88c5\uff09<\/td>\n<td>\u00a513,597<\/td>\n<td>\u6307\u4ee402\u6807\u51c6\u4ef7\u00b7page_id=662<\/td>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u94fa\u8bbe87.5\u33a1\uff08\u6807\u51c6\u6863\uff09<\/td>\n<td>\u00a512,688<\/td>\n<td>\u4f1f\u661f\u7ba1+\u66fc\u745e\u5fb7\u5206\u63a7+\u56de\u586b<\/td>\n<\/tr>\n<tr>\n<td>\u56fd\u8865\u6263\u51cf<\/td>\n<td>\u2212\u00a51,500<\/td>\n<td>\u7b26\u5408\u6761\u4ef6\u53ef\u62b5\u6263<\/td>\n<\/tr>\n<tr>\n<td style=\"font-weight:700;background:#E8F0FE;\">\u5730\u6696\u5230\u624b\u4ef7<\/td>\n<td style=\"font-weight:700;background:#E8F0FE;\">\u00a524,785<\/td>\n<td>\u9505\u7089+\u94fa\u8bbe+\u56fd\u8865<\/td>\n<\/tr>\n<tr style=\"background:#FFF8E1;\">\n<td style=\"font-weight:700;font-size:0.9rem;\">\u5168\u5c4b\u603b\u8ba1<\/td>\n<td style=\"font-weight:700;font-size:0.9rem;color:#E87A2A;\">\u2248\u00a554,868<\/td>\n<td>\u7a7a\u8c03\u00a530,083 + \u5730\u6696\u00a524,785<\/td>\n<\/tr>\n<\/table>\n<p>    <!-- \ud83c\udff7\ufe0f \u54c1\u724c\u6708\u6d3b\u52a8\u62a5\u4ef7\uff08\u6307\u4ee43\u65b0\u589e\uff09 --><\/p>\n<div class=\"info-box trust\" style=\"border-left-color:#C8960C;margin:16px 0;\">\n      <strong>\ud83c\udff7\ufe0f \u3010\u54c1\u724c\u6708\u6d3b\u52a8\u62a5\u4ef7 \u00b7 \u4e00\u4eba\u4e00\u5883 \u8212\u723d\u4e00\u590f\u3011<\/strong><br \/>\n      <span style=\"font-size:0.8rem;color:#555;\">\u6d3b\u52a8\u65f6\u95f4\uff1a2026.7.24 \u2014 8.24 | \u672c\u65b9\u6848\u5df2\u6309\u54c1\u724c\u6708\u6d3b\u52a8\u89c4\u5219\u6267\u884c \u00b7 \u9f99\u8109\u6696\u901a22\u5e74\u65e5\u7acb\u6388\u6743<\/span><\/p>\n<p>      <strong>\ud83d\udccb \u54c1\u724c\u6708\u6743\u76ca\u62b5\u6263\u660e\u7ec6\uff1a<\/strong><br \/>\n      \u2460 \u54c1\u724c\u6708\u5382\u8865\uff08\u8212\u4eab\u53cc\u98ce\u6247140\u578b\uff09\uff1a<strong>\u2212\u00a5600<\/strong>\uff08\u4f1a\u5458\u5c0f\u7a0b\u5e8f\u8d2d\u4e70\u5e76\u6838\u9500\uff09<br \/>\n      \u2461 \u56fd\u8865\uff1a<strong>\u2212\u00a51,500<\/strong>\uff08\u7b26\u5408\u6761\u4ef6\u53ef\u62b5\u6263\uff09<br \/>\n      \u2462 \u6298\u4e0a\u62985%\uff08\u4f1a\u5458\uff09\uff1a<strong>\u2212\u00a51,216<\/strong><br \/>\n      \u2463 \u4f1a\u5458\u4f18\u60e0\uff1a<strong>\u2212\u00a51,000<\/strong><br \/>\n      <strong>\u603b\u6743\u76ca\u62b5\u6263\uff1a\u2212\u00a54,316<\/strong><\/p>\n<p>      <strong>\ud83d\udd12 10\u5e74\u8d28\u4fdd\uff1a<\/strong>\u672c\u65b9\u6848\u8212\u4eab\u7cfb\u5217\u4eab\u65e5\u7acb\u5b98\u65b9 <strong>10\u5e74\u6574\u673a\u8d28\u4fdd<\/strong>\uff08EX\u8212\u4eab\/\u4e91\u7b51\/\u7f8e\u7b51\u3001mini\u2161\u53ca\u4ee5\u4e0a\u7cfb\u5217\u9002\u7528\uff09<\/p>\n<p>      <strong>\ud83d\udcca 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff1a<\/strong>\u54c1\u724c\u6708\u671f\u95f4\u7b7e\u7ea6\u5ba2\u6237\u81ea\u52a8\u52a0\u5165<br \/>\n      \u2022 B\u7ec4\u4e24\u8054\u4f9b\u5ba2\u6237\uff1a\u667a\u80fd\u7535\u8868 + AI\u80fd\u6e90\u7ba1\u5bb6 + \u5e74\u5ea6\u62a5\u544a<br \/>\n      \u2022 A\u7ec4\u9505\u7089\u5ba2\u6237\uff1a\u5e74\u5ea6\u7528\u6c14\u8ddf\u8e2a + \u540c\u6237\u578b\u5bf9\u6807<br \/>\n      \u2022 \u6240\u6709\u5ba2\u6237\uff1a\u7ec8\u8eab\u6863\u6848 + 20\u5e74\u670d\u52a1\u4fdd\u969c + \u4f1a\u5458\u6743\u76ca\n    <\/div>\n<p>    <!-- \u4e5d\u5bab\u683c\u77e9\u9635\uff08\u7a7a\u8c032\u00d7\u5730\u66963+\u9505\u70893 = \u591a\u79cd\u7ec4\u5408\uff09 --><\/p>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:18px 0 6px;\">\ud83d\udccb \u7ec4\u5408\u603b\u4ef7\u77e9\u9635 \u2b50<\/h4>\n<table class=\"matrix\">\n<tr>\n<th>\u7a7a\u8c03 \u2192 \uff0f \u5730\u6696 \u2193<\/th>\n<th>\u65b9\u6848\u4e00 \u00b7 \u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848<br \/>\u00a528,521<\/th>\n<th class=\"hl\">\u65b9\u6848\u4e8c \u00b7 \u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848 \u2605<br \/>\u00a530,083<\/th>\n<th>\u65b9\u6848\u4e09 \u00b7 20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848<br \/>\u00a526,510<\/th>\n<\/tr>\n<tr>\n<td class=\"rl\">\u7ecf\u6d4e\u6863 \u00a5125\/\u33a1<small>\u83f2\u65af\u66fc\u00a513,597<\/small><\/td>\n<td>\u2248\u00a551,556<\/td>\n<td class=\"hl\">\u2248\u00a553,118<\/td>\n<td>\u2248\u00a550,008<\/td>\n<\/tr>\n<tr>\n<td class=\"rl\">\u2705 \u6807\u51c6\u6863 \u00a5145\/\u33a1<small>\u83f2\u65af\u66fc\u00a513,597<\/small><\/td>\n<td>\u2248\u00a553,306<\/td>\n<td class=\"hl\">\u2248\u00a554,868<\/td>\n<td>\u2248\u00a552,758<\/td>\n<\/tr>\n<tr>\n<td class=\"rl\">\u8212\u9002\u6863 \u00a5179\/\u33a1<small>\u83f2\u65af\u66fc\u00a513,597<\/small><\/td>\n<td>\u2248\u00a556,281<\/td>\n<td class=\"hl\">\u2248\u00a557,843<\/td>\n<td>\u2248\u00a555,733<\/td>\n<\/tr>\n<\/table>\n<p style=\"font-size:0.72rem;color:#999;margin-top:4px;\">* \u9505\u7089\u7edf\u4e00\u6309\u83f2\u65af\u66fcB1JG \u00a513,597\uff08\u542b\u5b89\u88c5\uff09\u8ba1\uff0c\u5df2\u542b\u56fd\u8865-\u00a51,500\u3002\u6307\u4ee402\u4ef7\u683c\u5e93 page_id=662\u3002<\/p>\n<p>    <!-- \u4e3b\u63a8\u4e09\u6863 --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:16px 0 6px;\">\u2605 \u4e3b\u63a8\u4e09\u6863\u65b9\u6848<\/h4>\n<div class=\"rec-grid\">\n<div class=\"rec-card rec-eco\">\n<div class=\"rh\">\n<div class=\"rt\">\u7ecf\u6d4e\u578b<\/div>\n<div class=\"rs\">\u5355\u98ce\u6247+\u7ecf\u6d4e\u6863\u5730\u6696<\/div>\n<\/div>\n<div class=\"rb\">\n<div class=\"rp\">\u2248\u00a551,556<\/div>\n<div class=\"rd\">\u65b9\u6848\u4e00+\u7ecf\u6d4e\u6863\u5730\u6696<br \/>\u5916\u673a\u4f4d\u7a84\u9009\u6b64\u65b9\u6848<\/div>\n<div class=\"rbk\">\u7a7a\u8c03\u00a528,521 \u00b7 \u5730\u6696\u00a523,035<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"rec-card feat rec-bal\">\n<div class=\"rh\">\n<div class=\"rt\">\u2605 \u4e3b\u63a8\u00b7\u5747\u8861\u578b<\/div>\n<div class=\"rs\">\u53cc\u98ce\u6247+\u6807\u51c6\u6863\u5730\u6696<\/div>\n<\/div>\n<div class=\"rb\">\n<div class=\"rp\">\u2248\u00a554,868<\/div>\n<div class=\"rd\">\u65b9\u6848\u4e8c+\u6807\u51c6\u6863\u5730\u6696<br \/>\u566a\u97f3\u4f4e\u00b7\u6563\u70ed\u5f3a\u00b7\u6027\u4ef7\u6bd4\u6700\u4f18<\/div>\n<div class=\"rbk\">\u7a7a\u8c03\u00a530,083 \u00b7 \u5730\u6696\u00a524,785<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"rec-card rec-sav\">\n<div class=\"rh\">\n<div class=\"rt\">\u8212\u9002\u578b<\/div>\n<div class=\"rs\">\u53cc\u98ce\u6247+\u8212\u9002\u6863\u5730\u6696<\/div>\n<\/div>\n<div class=\"rb\">\n<div class=\"rp\">\u2248\u00a557,843<\/div>\n<div class=\"rd\">\u65b9\u6848\u4e09+\u8212\u9002\u6863\u5730\u6696<br \/>32\u7ba1\u5927\u6d41\u91cf\u00b7WiFi\u8054\u52a8\u00b7\u957f\u671f\u8282\u80fd<\/div>\n<div class=\"rbk\">\u7a7a\u8c03\u00a530,083 \u00b7 \u5730\u6696\u00a527,760<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \ud83d\udce1 \u4e5d\u7ef4\u5ea6\u96f7\u8fbe\u56fe --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:16px 0 6px;\">\ud83d\udce1 \u4e5d\u7ef4\u5ea6\u7efc\u5408\u5bf9\u6bd4<\/h4>\n<div class=\"radar-wrap\">\n      <canvas id=\"radarChart\" width=\"500\" height=\"500\"><\/canvas>\n    <\/div>\n<p>    <!-- 20\u5e74\u603b\u8d26\u5361 --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:16px 0 6px;\">\u23f3 20\u5e74\u4f7f\u7528\u6210\u672c\u4f30\u7b97<\/h4>\n<div class=\"lcc-w\">\n<div class=\"lcc-i\">\n<div class=\"lcc-f\" style=\"padding:20px;display:flex;flex-direction:column;align-items:center;justify-content:center;\">\n<h4 style=\"font-size:0.9rem;color:#003A70;margin-bottom:10px;\">\ud83d\udcca 20\u5e74\u603b\u8d26 \u00b7 \u65b9\u6848\u5bf9\u6bd4<\/h4>\n<div style=\"display:flex;gap:24px;align-items:flex-end;height:120px;padding:10px 0;\">\n<div style=\"text-align:center;\">\n<div style=\"width:50px;background:linear-gradient(to top,#c0392b,#e74c3c);height:60px;border-radius:4px 4px 0 0;margin:0 auto;\"><\/div>\n<div style=\"font-size:0.7rem;color:#555;margin-top:4px;\">\u539f\u59cb\u60f3\u6cd5<br \/>\u2248\u00a5169K<\/div>\n<\/p><\/div>\n<div style=\"text-align:center;\">\n<div style=\"width:50px;background:linear-gradient(to top,#1a3a5c,#2980b9);height:100px;border-radius:4px 4px 0 0;margin:0 auto;\"><\/div>\n<div style=\"font-size:0.7rem;color:#555;margin-top:4px;\">\u6027\u4ef7\u6bd4\u2605<br \/>\u2248\u00a5139K<\/div>\n<\/p><\/div>\n<div style=\"text-align:center;\">\n<div style=\"width:50px;background:linear-gradient(to top,#27ae60,#2ecc71);height:92px;border-radius:4px 4px 0 0;margin:0 auto;\"><\/div>\n<div style=\"font-size:0.7rem;color:#555;margin-top:4px;\">20\u5e74\u957f\u6548<br \/>\u2248\u00a5145K<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:4px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u8ba1\u7b97\u660e\u7ec6<\/div>\n<\/p><\/div>\n<div class=\"lcc-b\" style=\"padding:20px;\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:8px;\">\ud83d\udcd0 20\u5e74\u603b\u8d26\u8ba1\u7b97\u516c\u5f0f<\/h4>\n<div style=\"font-size:0.78rem;color:#555;line-height:1.8;\">\n            <strong>\u516c\u5f0f\uff1a<\/strong>\u603b\u6210\u672c\u2082\u2080 = C\u2080 + 20\u00d7R + 20\u00d7M + \u66f4\u6362\u6210\u672c<br \/>\n            <strong>C\u2080 \u521d\u6295\u8d44\uff1a<\/strong>\u539f\u59cb\u60f3\u6cd5\u00a574K \/ \u6027\u4ef7\u6bd4\u00a570K \/ 20\u5e74\u957f\u6548\u00a576K<br \/>\n            <strong>R \u5e74\u8fd0\u884c\u8d39\uff1a<\/strong>\u539f\u59cb\u60f3\u6cd5\u00a54.8K\/\u5e74 \/ \u6027\u4ef7\u6bd4\u00a53.8K\/\u5e74 \/ 20\u5e74\u957f\u6548\u00a53.5K\/\u5e74<br \/>\n            <strong>M \u5e74\u7ef4\u62a4\u8d39\uff1a<\/strong>\u539f\u59cb\u60f3\u6cd5\u00a5600\/\u5e74 \/ \u6027\u4ef7\u6bd4\u00a5400\/\u5e74 \/ 20\u5e74\u957f\u6548\u00a5400\/\u5e74<br \/>\n            <strong>15\u5e74\u66f4\u6362\uff1a<\/strong>\u539f\u59cb\u60f3\u6cd5\u00a537K \/ \u6027\u4ef7\u6bd4\u00a535K \/ 20\u5e74\u957f\u6548\u00a535K<br \/>\n            <strong>\u25b6 \u7ed3\u8bba\uff1a<\/strong>\u6027\u4ef7\u6bd4\u65b9\u684820\u5e74\u7701\u7ea6\u00a530,000\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u2462 \u516d\u7ef4\u8bc4\u5206\u8868\uff08S3\u65b0\u589e\uff0c\u9759\u2192\u8282\u2192\u8212\u2192\u5065\u2192\u521d\u2192\u4fdd\uff09 --><\/p>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:18px 0 8px;\">\n<div class=\"lm-flip-card\" style=\"margin:12px 0;\">\n<div class=\"lm-flip-inner\" style=\"min-height:300px;\">\n<div class=\"lm-flip-front\" style=\"padding:20px;display:flex;flex-direction:column;align-items:center;justify-content:center;\">\n<h4 style=\"font-size:0.9rem;color:#003A70;margin-bottom:10px;\">\ud83d\udcca \u516d\u7ef4\u5ea6\u7efc\u5408\u8bc4\u5206<\/h4>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:8px;width:100%;max-width:400px;\">\n<div style=\"font-size:0.78rem;color:#555;\">\u521d\u6295\u8d44<\/div>\n<div style=\"text-align:right;\"><span style=\"color:#C8A44E;\">\u2605\u2605\u2605\u2605<\/span><span style=\"color:#ddd;\">\u2605<\/span><\/div>\n<div style=\"font-size:0.78rem;color:#555;\">\u8fd0\u884c\u8d39<\/div>\n<div style=\"text-align:right;\"><span style=\"color:#C8A44E;\">\u2605\u2605\u2605\u2605\u2605<\/span><\/div>\n<div style=\"font-size:0.78rem;color:#555;\">\u8212\u9002\u5ea6<\/div>\n<div style=\"text-align:right;\"><span style=\"color:#C8A44E;\">\u2605\u2605\u2605\u2605<\/span><span style=\"color:#ddd;\">\u2605<\/span><\/div>\n<div style=\"font-size:0.78rem;color:#555;\">\u7a33\u5b9a\u6027<\/div>\n<div style=\"text-align:right;\"><span style=\"color:#C8A44E;\">\u2605\u2605\u2605\u2605\u2605<\/span><\/div>\n<div style=\"font-size:0.78rem;color:#555;\">\u7ef4\u62a4\u8d39<\/div>\n<div style=\"text-align:right;\"><span style=\"color:#C8A44E;\">\u2605\u2605\u2605\u2605<\/span><span style=\"color:#ddd;\">\u2605<\/span><\/div>\n<div style=\"font-size:0.78rem;color:#555;\">\u5bff\u547d<\/div>\n<div style=\"text-align:right;\"><span style=\"color:#C8A44E;\">\u2605\u2605\u2605\u2605<\/span><span style=\"color:#ddd;\">\u2605<\/span><\/div>\n<\/p><\/div>\n<div style=\"font-size:0.72rem;color:#999;margin-top:8px;\">\ud83d\udd04 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u8be6\u7ec6\u5bf9\u6bd4<\/div>\n<\/p><\/div>\n<div class=\"lm-flip-back\" style=\"padding:20px;\">\n<h4 style=\"font-size:0.9rem;color:#003A70;margin-bottom:8px;\">\u516d\u7ef4\u5ea6 \u00b7 \u65b9\u6848\u4e00 vs \u65b9\u6848\u4e8c vs \u65b9\u6848\u4e09<\/h4>\n<table style=\"width:100%;border-collapse:collapse;font-size:0.76rem;\">\n<tr>\n<th style=\"background:#003A70;color:#fff;padding:6px 10px;text-align:left;\">\u7ef4\u5ea6<\/th>\n<th style=\"background:#003A70;color:#fff;padding:6px 10px;text-align:left;\">\u65b9\u6848\u4e00<\/th>\n<th style=\"background:#003A70;color:#fff;padding:6px 10px;text-align:left;\">\u65b9\u6848\u4e8c \u2605<\/th>\n<th style=\"background:#003A70;color:#fff;padding:6px 10px;text-align:left;\">\u65b9\u6848\u4e09<\/th>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\ud83d\udcb0 \u521d\u6295\u8d44<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2606\u2606\u2606 \u00a574,000<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2606 \u00a570,000<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2606\u2606 \u00a576,000<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u26a1 \u8fd0\u884c\u8d39<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2606\u2606\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\ud83c\udf21\ufe0f \u8212\u9002\u5ea6<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2606\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2606\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\ud83d\udd27 \u7a33\u5b9a\u6027<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2606\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\ud83d\udd29 \u7ef4\u62a4\u8d39<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2606\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2606<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u23f3 \u5bff\u547d<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2606\u2606\u2606<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<td style=\"padding:5px 10px;border-bottom:1px solid #E8ECF0;\">\u2605\u2605\u2605\u2605\u2605<\/td>\n<\/tr>\n<\/table>\n<div style=\"font-size:0.74rem;color:#003A70;font-weight:600;margin-top:8px;\">\u25b6 \u63a8\u8350\u7ed3\u8bba\uff1a\u65b9\u6848\u4e8c\u6027\u4ef7\u6bd4\u6700\u4f18<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/div><\/div>\n<\/div>\n<p><!-- ========================================================== --><br \/>\n<!-- S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8 --><br \/>\n<!-- ========================================================== --><\/p>\n<div class=\"section\" id=\"s4\">\n<div class=\"section-inner s4\">\n<div class=\"section-title\">S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8<\/div>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:14px 0 6px;\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:14px 0 6px;\">\ud83d\udccb \u8f85\u6750\u914d\u7f6e\u6807\u51c6<\/h4>\n<table style=\"width:100%;border-collapse:collapse;font-size:0.78rem;background:#fff;border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.06);margin:10px 0;\">\n<tr>\n<th style=\"background:#003A70;color:#fff;padding:8px 12px;text-align:left;\">\u8f85\u6750\u540d\u79f0<\/th>\n<th style=\"background:#003A70;color:#fff;padding:8px 12px;text-align:left;\">\u54c1\u724c\/\u89c4\u683c<\/th>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u51b7\u5a92\u94dc\u7ba1<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u9f99\u715c\/\u6d77\u4eae \u00b7 R410A\u4e13\u7528<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4fdd\u6e29\u68c9<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4f18\u83f2\u7279 \u00b7 \u65e5\u7acb\u4e13\u7528 \u00b7 B1\u7ea7\u963b\u71c3<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u51b7\u51dd\u6c34\u7ba1<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4e2d\u8d22\/\u4f1f\u661f \u00b7 PVC-U<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4fe1\u53f7\u7ebf<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u65e5\u7acb\u539f\u88c5 \u00b7 \u5c4f\u853d\u53cc\u7ede\u7ebf<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u5730\u6696\u4e3b\u7ba1<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4f1f\u661f \u00b7 FPPR \u00b7 32\u7ba1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u5730\u6696\u76d8\u7ba1<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4f1f\u661f \u00b7 PE-RT \u00b7 20\u7ba1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u5206\u96c6\u6c34\u5668<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u4f1f\u661f<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u6e29\u63a7\u9762\u677f<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u66fc\u745e\u5fb7WiFi\u7ebf\u63a7\u5668<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u8054\u52a8\u63a7\u5236<\/td>\n<td style=\"padding:7px 12px;border-bottom:1px solid #E8ECF0;\">\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236<\/td>\n<\/tr>\n<\/table>\n<p style=\"font-size:0.74rem;color:#888;margin:4px 0 10px;\">\u9f99\u8109\u6696\u901a22\u5e74\u65e5\u7acb\u6388\u6743 \u00b7 \u8f85\u6750\u54c1\u724c\u900f\u660e\uff0c\u5047\u4e00\u8d54\u5341<\/p>\n<p>\ud83d\udcf8 \u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f<\/h4>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:10px 0;\">\n<div style=\"border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.08);\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u65e5\u7acb\u8212\u4eab\u5916\u673a\u6750\u6599\u8fdb\u573a\u6838\u9a8c\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;display:block;\"><\/a><\/p>\n<div style=\"padding:6px 10px;font-size:0.74rem;color:#555;background:#F8FAFC;\">\u2460 \u6750\u6599\u8fdb\u573a<\/div>\n<\/p><\/div>\n<div style=\"border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.08);\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/ayly-sls-ktnjazys6.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/ayly-sls-ktnjazys6.jpg\" alt=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5185\u673a\u53cc\u51cf\u9707\u540a\u88c5\u5b89\u88c5\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;display:block;\"><\/a><\/p>\n<div style=\"padding:6px 10px;font-size:0.74rem;color:#555;background:#F8FAFC;\">\u2461 \u5185\u673a\u5b89\u88c5<\/div>\n<\/p><\/div>\n<div style=\"border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.08);\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/xfsg2q-dls-ktxhmaz.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/xfsg2q-dls-ktxhmaz.jpg\" alt=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;display:block;\"><\/a><\/p>\n<div style=\"padding:6px 10px;font-size:0.74rem;color:#555;background:#F8FAFC;\">\u2462 \u51b7\u51dd\u6c34\u7ba1<\/div>\n<\/p><\/div>\n<div style=\"border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.08);\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/hxbjjc-hls-ktdqbh.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/hxbjjc-hls-ktdqbh.jpg\" alt=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;display:block;\"><\/a><\/p>\n<div style=\"padding:6px 10px;font-size:0.74rem;color:#555;background:#F8FAFC;\">\u2463 \u94dc\u7ba1\u710a\u63a5\uff08\u6c2e\u6c14\u4fdd\u62a4\u710a\uff09<\/div>\n<\/p><\/div>\n<div style=\"border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.08);\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" alt=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u6c2e\u6c14\u4fdd\u538b24\u5c0f\u65f6\u6d4b\u8bd5\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;display:block;\"><\/a><\/p>\n<div style=\"padding:6px 10px;font-size:0.74rem;color:#555;background:#F8FAFC;\">\u2464 \u6c2e\u6c14\u4fdd\u538b<\/div>\n<\/p><\/div>\n<div style=\"border-radius:8px;overflow:hidden;box-shadow:0 2px 8px rgba(0,0,0,0.08);\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u7cfb\u7edf\u8c03\u8bd5\u8fd0\u884c\u68c0\u6d4b\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;display:block;\"><\/a><\/p>\n<div style=\"padding:6px 10px;font-size:0.74rem;color:#555;background:#F8FAFC;\">\u2465 \u8c03\u8bd5\u4ea4\u4ed8<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \ud83d\udcdc \u2460 \u65e5\u7acb\u54c1\u724c\u6388\u6743\u8d44\u8d28 --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #E8ECF0;\">\ud83d\udcdc \u2460 \u65e5\u7acb\u54c1\u724c\u6388\u6743\u8d44\u8d28<\/h4>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin:12px 0;\">\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,0.08);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u67432026\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;height:400px;object-fit:contain;background:#F5F5F5;display:block;\"><\/a><\/p>\n<div style=\"padding:10px 12px;font-size:0.78rem;color:#003A70;font-weight:600;text-align:center;border-top:1px solid #F0F0F0;\">\ud83c\udfc5 \u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\uff082026\uff09<\/div>\n<\/p><\/div>\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,0.08);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u67432026\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;height:400px;object-fit:contain;background:#F5F5F5;display:block;\"><\/a><\/p>\n<div style=\"padding:10px 12px;font-size:0.78rem;color:#003A70;font-weight:600;text-align:center;border-top:1px solid #F0F0F0;\">\ud83d\udcdc \u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u5546\uff082026\uff09<\/div>\n<\/p><\/div>\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,0.08);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u67432024\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;height:400px;object-fit:contain;background:#F5F5F5;display:block;\"><\/a><\/p>\n<div style=\"padding:10px 12px;font-size:0.78rem;color:#003A70;font-weight:600;text-align:center;border-top:1px solid #F0F0F0;\">\ud83e\udd47 \u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u5546\uff082024\uff09<\/div>\n<\/p><\/div>\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,0.08);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u6388\u67432026\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;height:400px;object-fit:contain;background:#F5F5F5;display:block;\"><\/a><\/p>\n<div style=\"padding:10px 12px;font-size:0.78rem;color:#003A70;font-weight:600;text-align:center;border-top:1px solid #F0F0F0;\">\ud83d\udd27 \u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u5546\uff082026\uff09<\/div>\n<\/p><\/div>\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,0.08);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u00b7\u9f99\u8109\u6696\u901a\" loading=\"lazy\" style=\"width:100%;height:400px;object-fit:contain;background:#F5F5F5;display:block;\"><\/a><\/p>\n<div style=\"padding:10px 12px;font-size:0.78rem;color:#003A70;font-weight:600;text-align:center;border-top:1px solid #F0F0F0;\">\ud83d\udca7 \u65e5\u7acb\u6c34\u5885\u9002\u7ecf\u9500\u6388\u6743<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \ud83d\udccd \u2461 \u9f99\u8109\u6696\u901a\u95e8\u5e97\u5b9e\u666f --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:28px 0 10px;padding-bottom:6px;border-bottom:2px solid #E8ECF0;\">\ud83d\udccd \u2461 \u9f99\u8109\u6696\u901a\u95e8\u5e97\u5b9e\u666f<\/h4>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:12px 0;\">\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 3px 14px rgba(0,0,0,0.1);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97\" loading=\"lazy\" style=\"width:100%;height:300px;object-fit:cover;display:block;cursor:pointer;\"><\/a><\/p>\n<div style=\"padding:14px 16px;\">\n<div style=\"font-size:0.85rem;font-weight:600;color:#003A70;margin-bottom:4px;\">\ud83c\udfea \u5357\u5bcc\u68ee\u5e97<\/div>\n<div style=\"font-size:0.78rem;color:#666;\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f73\u697cA348 \u00b7 028-86131795<\/div>\n<div style=\"margin-top:4px;\"><a href=\"https:\/\/apis.map.qq.com\/uri\/v1\/geo?center=30.5778,104.0501&amp;coord_type=1&amp;zoom=16&amp;name=\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97&amp;address=\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\" target=\"_blank\" style=\"color:#003A70;font-size:0.76rem;\">\ud83d\uddfa\ufe0f \u5bfc\u822a\u5230\u5e97<\/a> \uff5c \u987e\u95ee\u90ed\u52c7\u79c0 <a href=\"tel:18100839248\" style=\"color:#003A70;text-decoration:underline;\">181-0083-9248<\/a><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div style=\"border-radius:12px;overflow:hidden;box-shadow:0 3px 14px rgba(0,0,0,0.1);background:#fff;\">\n        <a href=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986\" loading=\"lazy\" style=\"width:100%;height:300px;object-fit:cover;display:block;cursor:pointer;\"><\/a><\/p>\n<div style=\"padding:14px 16px;\">\n<div style=\"font-size:0.85rem;font-weight:600;color:#003A70;margin-bottom:4px;\">\ud83c\udfea \u5317\u5bcc\u68ee\u5e97<\/div>\n<div style=\"font-size:0.78rem;color:#666;\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135 \u00b7 028-65272586<\/div>\n<div style=\"margin-top:4px;\"><a href=\"https:\/\/apis.map.qq.com\/uri\/v1\/geo?center=30.6358,104.1204&amp;coord_type=1&amp;zoom=16&amp;name=\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97&amp;address=\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135\" target=\"_blank\" style=\"color:#003A70;font-size:0.76rem;\">\ud83d\uddfa\ufe0f \u5bfc\u822a\u5230\u5e97<\/a> \uff5c \u65b9\u6848\u987e\u95ee\uff1a\u90ed\u52c7\u79c0<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0;\">\n<div style=\"background:#F8FAFC;border-radius:10px;padding:14px;border:1px solid #E8ECF0;\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:4px;\">\ud83c\udfc6 2025\u94bb\u77f3\u5b89\u88c5\u5546<\/h4>\n<p style=\"font-size:0.76rem;color:#666;line-height:1.5;\">\u65e5\u7acb\u6700\u9ad8\u7b49\u7ea7\u8ba4\u8bc1 \u00b7 \u5b98\u65b9\u7279\u7ea6\u7ecf\u9500\u5546 \u00b7 \u91d1\u724c\u5b89\u88c5\u56e2\u961f<\/p>\n<\/p><\/div>\n<div style=\"background:#FFF8E1;border-radius:10px;padding:14px;border:1px solid #E8ECF0;\">\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:4px;\">\ud83d\udcca 10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/h4>\n<p style=\"font-size:0.76rem;color:#666;line-height:1.5;\">\u7b2c1\u5e74\u521d\u59cb\u6863\u6848 \u2192 \u7b2c3\u5e74\u8d8b\u52bf \u2192 \u7b2c5\u5e74\u5065\u5eb7\u8bca\u65ad \u2192 \u7b2c10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"confirm-box\">\u3010S4\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c\u5df2\u660e\u786e\u3002\u8bf7\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u7ba1\u8def\u8d70\u5411\u3001\u5206\u6c34\u5668\u4f4d\u7f6e\uff1b\u786e\u8ba4\u540e\u56de\u590d\u300c\u786e\u8ba4\u300d\uff0c\u63a8\u8fdb S5\u3002\u3011<\/div>\n<\/p><\/div>\n<\/div>\n<p><!-- ========================================================== --><br \/>\n<!-- S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u9009\u578b\u8fed\u4ee3 --><br \/>\n<!-- ========================================================== --><\/p>\n<div class=\"section\" id=\"s5\">\n<div class=\"section-inner s5\">\n<div class=\"section-title\">S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u9009\u578b\u8fed\u4ee3<\/div>\n<div class=\"section-sub\">\u516d\u7ef4\u5ea6\u5bf9\u6bd4 \u00b7 \u6848\u4f8b\u53c2\u7167 \u00b7 AI\u9a8c\u8bc1 \u00b7 FAQ<\/div>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin-bottom:6px;\">\ud83d\udcca \u516d\u7ef4\u5ea6\u7efc\u5408\u5bf9\u6bd4\uff08\u9759\u97f3\u2192\u8282\u80fd\u2192\u8212\u9002\u2192\u5065\u5eb7\u2192\u521d\u6295\u2192\u4fdd\u969c\uff09<\/h4>\n<div class=\"dim-g\">\n<div class=\"dim-it\">\n<div class=\"dn\">\ud83d\udd07 \u9759\u97f3\u6027<\/div>\n<div class=\"ds\"><span>\u5355\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><span>\u53cc\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2605<\/span><\/span><\/div>\n<\/div>\n<div class=\"dim-it\">\n<div class=\"dn\">\u26a1 \u8282\u80fd\u6027<\/div>\n<div class=\"ds\"><span>\u5355\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2605<\/span><\/span><span>\u53cc\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><\/div>\n<\/div>\n<div class=\"dim-it\">\n<div class=\"dn\">\ud83d\ude0a \u8212\u9002\u5ea6<\/div>\n<div class=\"ds\"><span>\u5355\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><span>\u53cc\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2605<\/span><\/span><\/div>\n<\/div>\n<div class=\"dim-it\">\n<div class=\"dn\">\u2764\ufe0f \u5065\u5eb7\u6027<\/div>\n<div class=\"ds\"><span>\u5355\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><span>\u53cc\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><\/div>\n<\/div>\n<div class=\"dim-it\">\n<div class=\"dn\">\ud83d\udcb0 \u521d\u6295\u8d44<\/div>\n<div class=\"ds\"><span>\u5355\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2605<\/span><\/span><span>\u53cc\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><\/div>\n<\/div>\n<div class=\"dim-it\">\n<div class=\"dn\">\ud83d\udee1\ufe0f \u4fdd\u969c\u6027<\/div>\n<div class=\"ds\"><span>\u5355\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><span>\u53cc\u98ce\u6247<span class=\"dim-st\">\u2605\u2605\u2605\u2605\u2606<\/span><\/span><\/div>\n<\/div><\/div>\n<div class=\"info-box trust\">\n      <strong>\u2605 \u63a8\u8350\u65b9\u6848\uff1a\u65b9\u6848\u4e8c + \u6807\u51c6\u6863\u5730\u6696\uff08\u2248\u00a554,868\uff09<\/strong><br \/>\n      \u6bd4\u5355\u98ce\u6247\u65b9\u6848\u591a\u00a51,562\uff0c\u4f46\u53cc\u98ce\u6247\u566a\u97f3\u4f4e2dB\u3001\u98ce\u91cf\u592717%\u3001\u6563\u70ed\u66f4\u5f3a\uff0c\u4e143\u697c\u5916\u673a\u4f4d\u6761\u4ef6\u901a\u5e38\u826f\u597d\u3002\u82e5\u5916\u673a\u4f4d<1380mm\uff0c\u6539\u9009\u5355\u98ce\u6247\u65b9\u6848\uff08\u2248\u00a553,306\uff09\u3002<br \/>\n      <span style=\"font-size:0.74rem;color:#888;\">20\u5e74\u603b\u6295\u5165\u2248\u00a5193,368 \u00b7 \u5e74\u5316\u2248\u00a59,668\/\u5e74<\/span>\n    <\/div>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:14px 0 6px;\">\ud83c\udfe0 \u540c\u6237\u578b\u53c2\u8003\u6848\u4f8b<\/h4>\n<div class=\"case-g\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=4532\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"case-it\">\n<div class=\"cn\">\u5f90\u5148\u751f\u00b7\u4e1c\u5b89\u9996\u5e9c<\/div>\n<div class=\"cs\">\ud83d\udd17 \u76f8\u4f3c\uff1a\u8212\u4eab180\u62d66+\u65b0\u98ce<\/div>\n<div class=\"cv\">\u53c2\u8003\uff1a105\u33a1\u4f4f\u5b85\uff0c\u540c\u9762\u79ef\u6bb5\u65bd\u5de5\u4e0e\u914d\u7f6e\u7ecf\u9a8c<\/div>\n<\/p><\/div>\n<p><\/a><br \/>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=4667\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"case-it\">\n<div class=\"cn\">\u674e\u5973\u58eb\u00b7\u9526\u7cbc\u6e56\u9662<\/div>\n<div class=\"cs\">\ud83d\udd17 \u76f8\u4f3c\uff1a\u5c0a\u777f\u5168\u6548160\u4e00\u62d6\u516d<\/div>\n<div class=\"cv\">\u53c2\u8003\uff1a120\u33a1\u4f4f\u5b85\uff0c\u4e00\u62d6\u591a\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u8c03\u8bd5<\/div>\n<\/p><\/div>\n<p><\/a><br \/>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=5994\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"case-it\">\n<div class=\"cn\">\u674e\u5973\u58eb\u00b7\u8001\u623f\u5b50<\/div>\n<div class=\"cs\">\ud83d\udd17 \u76f8\u4f3c\uff1a\u65b9\u6848\u4e00\u4e00\u62d6\u56db<\/div>\n<div class=\"cv\">\u53c2\u8003\uff1a\u540c\u9762\u79ef\u6bb5\uff0c\u5730\u6696+\u4e2d\u592e\u7a7a\u8c03\u8054\u52a8\u65b9\u6848<\/div>\n<\/p><\/div>\n<p><\/a><\/p>\n<p>      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"case-it\">\n<div class=\"cn\">\ud83d\udcda \u5ba2\u6237\u6848\u4f8b\u5e93<\/div>\n<div class=\"cs\">\ud83d\udd17 200+\u771f\u5b9e\u6848\u4f8b<\/div>\n<div class=\"cv\">\u66f4\u591a\u540c\u6237\u578b\/\u540c\u7cfb\u7edf\u5b9e\u666f\u53c2\u8003<\/div>\n<\/p><\/div>\n<p><\/a>\n    <\/div>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:14px 0 6px;\">\u26a0\ufe0f \u5f85\u786e\u8ba4\u4fe1\u606f\uff08P0\/P1\uff09<\/h4>\n<div class=\"plist\">\n<div class=\"pitem p0\"><span class=\"pb\">P0<\/span> \u5916\u673a\u4f4d\u5bbd\u5ea6\u5b9e\u6d4b\uff08\u51b3\u5b9a\u5355\u98ce\u6247\u8fd8\u662f\u53cc\u98ce\u6247\uff09<\/div>\n<div class=\"pitem p0\"><span class=\"pb\">P0<\/span> \u662f\u5426\u6709\u897f\u6652\u6216\u5927\u9762\u79ef\u73bb\u7483\u7a97<\/div>\n<div class=\"pitem p1\"><span class=\"pb\">P1<\/span> \u5730\u669687.5\u33a1\u5168\u94fa\u6216\u90e8\u5206\u94fa\u8bbe<\/div>\n<div class=\"pitem p1\"><span class=\"pb\">P1<\/span> 3\u697c\u5c42\u9ad8\u5b9e\u6d4b\u6570\u636e<\/div>\n<div class=\"pitem p1\"><span class=\"pb\">P1<\/span> \u51b7\u51dd\u7089\u6392\u70df\u53e3\u4f4d\u7f6e\u786e\u8ba4<\/div>\n<\/p><\/div>\n<h4 style=\"font-size:0.85rem;color:#003A70;margin:14px 0 6px;\">\ud83e\udd16 AI\u8f85\u52a9\u9a8c\u8bc1\u6e05\u5355<\/h4>\n<div class=\"ai-list\">\n<div class=\"ai-item\" >\n<div class=\"ai-q\">\u2705 \u914d\u7f6e\u771f\u4f2a\u9a8c\u8bc1 <span class=\"ai-badge pass\">\u901a\u8fc7<\/span> <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"ai-a\">\u5916\u673aRAS-140HRNAQ\/HRNBQ\u3001\u5185\u673aRPIZ-40\/32\/25\/22FSNAQD\/P\u5747\u4e3a\u65e5\u7acb\u5728\u552e\u578b\u53f7\u3002DC\u8584\u578b\u5185\u673a192mm\u5c5e\u5b9e\u3002<\/div>\n<\/p><\/div>\n<div class=\"ai-item\" >\n<div class=\"ai-q\">\u2705 \u529f\u7387\u5339\u914d\u9a8c\u8bc1 <span class=\"ai-badge pass\">\u901a\u8fc7<\/span> <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"ai-a\">\u5185\u673a\u603b\u5bb9\u91cf17.2kW\uff0c\u5916\u673a14.0kW\uff0c\u8d85\u914d\u7387122.9%\u572850%-130%\u5408\u89c4\u533a\u95f4\uff0c\u4e3a\u7406\u60f3\u914d\u6bd4\u3002\u540c\u5f003\u53f0\u65f6\u5b9e\u9645\u8d1f\u8377\u7ea67-9kW\uff0c\u5916\u673a\u5bcc\u4f59\u3002<\/div>\n<\/p><\/div>\n<div class=\"ai-item\" >\n<div class=\"ai-q\">\u2705 \u5c42\u9ad8\u517c\u5bb9\u9a8c\u8bc1 <span class=\"ai-badge pass\">\u901a\u8fc7<\/span> <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"ai-a\">DC\u5185\u673a192mm\u539a\u5ea6\uff0c\u914d\u5408\u6807\u51c6\u540a\u9876\u6700\u4f4e\u53ef\u505a\u5230250mm\u5b8c\u6210\u9762\uff0c\u5bf93\u697c\u4f4f\u5b85\u975e\u5e38\u53cb\u597d\uff0c\u53ef\u7075\u6d3b\u8c03\u6574\u6881\u4f4d\u3002<\/div>\n<\/p><\/div>\n<div class=\"ai-item\" >\n<div class=\"ai-q\">\u2705 \u62a5\u4ef7\u4f9d\u636e\u9a8c\u8bc1 <span class=\"ai-badge pass\">\u901a\u8fc7<\/span> <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"ai-a\">\u4ef7\u683c\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a2026\u5e74V5.0\u4ef7\u683c\u6307\u4ee4\u5e93\uff08page_id=662\uff09\u3002\u7a7a\u8c03\u8bbe\u59078\u6298\uff0c\u5b89\u88c5\u8d39\u00a51,600\/\u53f0\u4e0d\u6253\u6298\uff0c\u83f2\u65af\u66fcB1JG 25kW\u4e3a\u6307\u4ee402\u6807\u51c6\u5355\u4ef7\u00a513,597\uff08\u542b\u5b89\u88c5\uff09\uff0c\u9505\u7089\u4e0d\u6253\u6298\u3002<\/div>\n<\/p><\/div>\n<div class=\"ai-item\" >\n<div class=\"ai-q\">\u2705 \u56fd\u6807+\u6848\u4f8b\u9a8c\u8bc1 <span class=\"ai-badge pass\">\u901a\u8fc7<\/span> <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"ai-a\">\u51b7\u8d1f\u8377160W\/\u33a1\u53c2\u8003GB 50736-2012\uff1b\u5730\u6696\u8bbe\u8ba1\u4f9d\u636eJGJ 142-2012\u3002\u5df2\u5f15\u7528\u540c\u9762\u79ef\u6bb5\u6848\u4f8b3\u9879\u3002<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u65b9\u6848\u52a3\u52bf\u8bda\u5b9e\u62ab\u9732 --><\/p>\n<div class=\"disclosure-box\">\n      <strong>\u26a0\ufe0f \u65b9\u6848\u52a3\u52bf\u8bda\u5b9e\u62ab\u9732<\/strong><br \/>\n      \u2022 \u65b9\u6848\u4e00\uff08\u539f\u59cb\u60f3\u6cd5\uff09\uff1a\u6781\u7aef\u9ad8\u6e29\u5de5\u51b5\u6563\u70ed\u7565\u5f31\uff0c\u5916\u673a\u957f\u671f\u9ad8\u8d1f\u8377\u8fd0\u884c\u53ef\u80fd\u5f71\u54cd\u5236\u51b7\u6548\u679c<br \/>\n      \u2022 \u65b9\u6848\u4e8c\uff08\u6027\u4ef7\u6bd4\u63a8\u8350\uff09\uff1a\u5916\u673a\u4f4d\u9700\u22651380mm\u5bbd\uff0c\u90e8\u5206\u6237\u578b\u5916\u673a\u4f4d\u53ef\u80fd\u4e0d\u6ee1\u8db3<br \/>\n      \u2022 \u5730\u6696\u7ecf\u6d4e\u6863\uff08\u00a5125\/\u33a1\uff09\uff1a\u4f1f\u661f\u603b\u63a7\uff0c\u65e0\u5206\u5ba4\u6e29\u63a7\uff0c\u5168\u5c4b\u7edf\u4e00\u6e29\u5ea6\u65e0\u6cd5\u6309\u623f\u95f4\u5355\u72ec\u8c03\u8282<br \/>\n      \u2022 \u4e2d\u592e\u7a7a\u8c03\u521d\u6295\u9ad8\u4e8e\u98ce\u7ba1\u673a\u2248\u00a51.3\u4e07\uff0c\u4f4620\u5e74\u603b\u8d26\u644a\u8584\u540e\u5e74\u5316\u66f4\u4f18\n    <\/div>\n<p>    <!-- FAQ --><\/p>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:14px 0 6px;\">\u2753 \u5e38\u89c1\u95ee\u9898<\/h4>\n<div class=\"faq-list\" id=\"faq\">\n<div class=\"faq-it\" >\n<div class=\"faq-q\">\u5355\u98ce\u6247\u548c\u53cc\u98ce\u6247\u600e\u4e48\u9009\uff1f <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"faq-a\">\u53cc\u98ce\u6247\u566a\u97f3\u4f4e2dB(52 vs 54dB)\u3001\u98ce\u91cf\u592717%\u3001\u6563\u70ed\u66f4\u5f3a\uff0c\u4f46\u5916\u673a\u4f4d\u9700\u22651380mm\u5bbd\u3002\u673a\u4f4d\u591f\u5bbd\u63a8\u8350\u53cc\u98ce\u6247\uff0c\u673a\u4f4d\u7a84\u9009\u5355\u98ce\u6247\uff0c\u540c\u6837\u8d85\u4e00\u7ea7\u80fd\u6548\u3002<\/div>\n<\/p><\/div>\n<div class=\"faq-it\" >\n<div class=\"faq-q\">192mm\u5185\u673a\u771f\u7684\u4e0d\u538b\u5c42\u9ad8\u5417\uff1f <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"faq-a\">\u8212\u4eabDC\u5185\u673a\u4ec5192mm\u539a\uff0c\u662f\u65e5\u7acb\u6700\u8584\u7cfb\u5217\u4e4b\u4e00\u3002\u914d\u5408\u6807\u51c6\u540a\u9876\u505a\u6cd5\uff0c\u6700\u4f4e\u53ef\u505a\u5230\u540a\u9876\u5b8c\u6210\u9762\u7ea6250mm\uff0c\u5bf93\u697c\u4f4f\u5b85\u975e\u5e38\u53cb\u597d\u3002\u5b89\u88c5\u65f6\u8fd8\u53ef\u6839\u636e\u6881\u4f4d\u7075\u6d3b\u8c03\u6574\u3002<\/div>\n<\/p><\/div>\n<div class=\"faq-it\" >\n<div class=\"faq-q\">\u5ba2\u538571+22\u53cc\u5185\u673a\u548c\u535571\u578b\u54ea\u4e2a\u597d\uff1f <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"faq-a\">71+22\u53cc\u5185\u673a\uff0c\u5ba2\u538546\u33a1\u752871\u578b\u4e3b\u533a+22\u578b\u8f85\u533a\uff0c\u8986\u76d6\u66f4\u5747\u5300\u3002\u535571\u578b\u7701\u94b1\u4f46\u96c6\u4e2d\u51fa\u98ce\u3002\u63a8\u8350\u53cc\u5185\u673a\u65b9\u6848\u3002<\/div>\n<\/p><\/div>\n<div class=\"faq-it\" >\n<div class=\"faq-q\">\u83f2\u65af\u66fcB1JG 25kW\u591f\u5e2687.5\u33a1\u5730\u6696\u5417\uff1f <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"faq-a\">\u6309\u6210\u90fd\u70ed\u8d1f\u8377100-130W\/\u33a1\u8ba1\u7b97\uff0c87.5\u33a1\u7ea68.8-11.4kW\uff0c25kW\u51b7\u51dd\u7089\u7ef0\u7ef0\u6709\u4f59\u3002\u5168\u9884\u6df7\u51b7\u51dd\u71c3\u70e7\u6548\u7387\u2265106%\uff0c\u957f\u671f\u66f4\u7701\u3002<\/div>\n<\/p><\/div>\n<div class=\"faq-it\" >\n<div class=\"faq-q\">\u4f1a\u5458\u6298\u4e0a\u62985%\u600e\u4e48\u7b97\uff1f <span class=\"arrow\">\u25be<\/span><\/div>\n<div class=\"faq-a\">\u5148\u4ea4199\u5143\u4f1a\u5458\u8d39\u6210\u4e3a\u9f99\u8109\u4f1a\u5458\uff0c\u4eab\u8bbe\u5907\u4ef7\u518d\u4f18\u60e05%\uff08\u7ea6\u00a51,216\uff09\uff0c\u540c\u65f6\u90015\u5e74\u4f1a\u5458\u6743\u76ca\uff08\u5ef6\u4fdd\u3001\u670d\u52a1\u6298\u6263\u3001\u514d\u8d39\u4e0a\u95e8\u7b49\uff09\u3002\u76f8\u5f53\u4e8e199\u6362\u56de1,216\u3002<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"confirm-box\">\u3010S5\uff1a\u6848\u4f8b\u9a8c\u8bc1\u4e0e\u9009\u578b\u5efa\u8bae\u5df2\u5b8c\u6210\u3002\u8bf7\u9500\u552e\u5b8c\u6210\u4eba\u5ba13\u9879\uff08\u914d\u7f6e\u771f\u4f2a\/\u62a5\u4ef7\u8131\u654f\/\u4e1a\u52a1\u5339\u914d\uff09\u540e\u653e\u884c\u53d1\u5e03\u3002\u3011<\/div>\n<\/p><\/div>\n<\/div>\n<p><!-- ===== \u5e95\u90e8\u94fe\u63a5\u5361 ===== --><\/p>\n<div class=\"section\">\n<div class=\"section-inner\" style=\"border-left-color:#C8960C;\">\n<div class=\"section-title\">\n<div class=\"section\" id=\"links\">\n<div class=\"section-title\">\u4e86\u89e3\u66f4\u591a<\/div>\n<div class=\"section-sub\">\u4ea7\u54c1\u8be6\u60c5 \u00b7 \u6848\u4f8b\u4e2d\u5fc3 \u00b7 \u6388\u6743\u95e8\u5e97 \u00b7 \u907f\u5751\u6307\u5357<\/div>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:14px 0;\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83d\udccb \u4ea7\u54c1\u8be6\u60c5 \u00b7 \u8212\u4eab\u7cfb\u5217<\/div>\n<div class=\"ld\">\u65e5\u7acb\u8212\u4eab\u5168\u7cfb\u5217\u4ea7\u54c1\u53c2\u6570\u3001\u9009\u578b\u6307\u5357\u3001\u6280\u672f\u89c4\u683c<\/div>\n<div class=\"lbtn\">\u67e5\u770b\u4ea7\u54c1 \u2192<\/div>\n<\/div>\n<p>      <\/a><br \/>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83c\udfe0 \u6848\u4f8b\u4e2d\u5fc3\uff08200+\uff09<\/div>\n<div class=\"ld\">\u6210\u90fd\u5168\u57df\u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b\uff0c\u540c\u6237\u578b\u6863\u6848\u4e0e\u65bd\u5de5\u5b9e\u5f55<\/div>\n<div class=\"lbtn\">\u67e5\u770b\u6848\u4f8b \u2192<\/div>\n<\/div>\n<p>      <\/a>\n    <\/div>\n<h4 style=\"font-size:0.9rem;color:#003A70;margin:16px 0 8px;\">\ud83d\udccd \u6388\u6743\u95e8\u5e97<\/h4>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;\">\n<div style=\"border-radius:10px;overflow:hidden;box-shadow:0 2px 12px rgba(0,0,0,0.06);background:#fff;padding:16px;\">\n<div style=\"font-size:0.85rem;font-weight:700;color:#003A70;margin-bottom:6px;\">\ud83c\udfea \u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/div>\n<div style=\"font-size:0.78rem;color:#555;line-height:1.7;\">\n          \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f73\u697cA348<br \/>\n          \ud83d\udcde 028-86131795<br \/>\n          \u987e\u95ee\uff1a\u90ed\u52c7\u79c0 <a href=\"tel:18100839248\" style=\"color:#003A70;text-decoration:underline;\">181-0083-9248<\/a>\n        <\/div>\n<\/p><\/div>\n<div style=\"border-radius:10px;overflow:hidden;box-shadow:0 2px 12px rgba(0,0,0,0.06);background:#fff;padding:16px;\">\n<div style=\"font-size:0.85rem;font-weight:700;color:#003A70;margin-bottom:6px;\">\ud83c\udfea \u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/div>\n<div style=\"font-size:0.78rem;color:#555;line-height:1.7;\">\n          \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<br \/>\n          \ud83d\udcde 028-65272586<br \/>\n          \u987e\u95ee\uff1a\u90ed\u52c7\u79c0 <a href=\"tel:18100839248\" style=\"color:#003A70;text-decoration:underline;\">181-0083-9248<\/a>\n        <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div style=\"margin-top:12px;\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\" style=\"text-decoration:none;color:inherit;\"><\/p>\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83d\udcd6 \u767d\u76ae\u4e66 \u00b7 \u4e2d\u592e\u7a7a\u8c03\u907f\u5751\u6307\u5357<\/div>\n<div class=\"ld\">\u4e3b\u673a\u9009\u578b\u3001\u5185\u673a\u642d\u914d\u3001\u5b89\u88c5\u9a8c\u6536\u3001\u62a5\u4ef7\u9632\u5751\u7b49\u5b9e\u7528\u77e5\u8bc6<\/div>\n<div class=\"lbtn\">\u67e5\u770b\u6307\u5357 \u2192<\/div>\n<\/div>\n<p>      <\/a>\n    <\/div>\n<\/p><\/div>\n<\/div>\n<div class=\"ld\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u65bd\u5de5\u6d41\u7a0b\u4e0e\u9a8c\u6536\u89c4\u8303\u3002<\/div>\n<p><a class=\"lbtn\" href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\">\u67e5\u770b\u6807\u51c6 \u2192<\/a><\/div>\n<\/p><\/div>\n<div class=\"link-g\">\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83d\udd25 \u9f99\u8109\u6696\u901a\u5730\u6696\u4e2d\u5fc3<\/div>\n<div class=\"ld\">\u4f1f\u661f\u7ba1\u9053\u00b7\u5730\u6696\u8bbe\u8ba1\u00b7\u65bd\u5de5\u6807\u51c6<\/div>\n<p><a class=\"lbtn\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u67e5\u770b\u5730\u6696 \u2192<\/a><\/div>\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83d\udd25 \u83f2\u65af\u66fc\u58c1\u6302\u7089\u7cfb\u5217<\/div>\n<div class=\"ld\">\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u00b7\u51b7\u51dd\u6280\u672f\u00b7B1JG\u53c2\u6570\u8be6\u60c5<\/div>\n<p><a class=\"lbtn\" href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\">\u67e5\u770b\u83f2\u65af\u66fc \u2192<\/a><\/div>\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83d\udcd6 \u9f99\u8109\u6696\u901a\u6280\u80fd\u5e93<\/div>\n<div class=\"ld\">\u6307\u4ee40-6\u00b7\u767d\u76ae\u4e66\u00b7\u7b56\u7565\u5361\u00b7\u5168\u8d44\u6e90\u7d22\u5f15<\/div>\n<p><a class=\"lbtn\" href=\"https:\/\/longmai-nt.com\/?page_id=1267\" target=\"_blank\">\u67e5\u770b\u6280\u80fd\u5e93 \u2192<\/a><\/div>\n<div class=\"link-cd\">\n<div class=\"lt\">\ud83d\udcd0 \u8212\u4eab\u53cc\u98ce\u6247\u9009\u578b\u6307\u5357<\/div>\n<div class=\"ld\">\u5916\u673a\u5185\u673a\u9009\u578b\u00b7\u5b89\u88c5\u5c3a\u5bf8\u00b7\u6280\u672f\u53c2\u6570\u00b7\u6848\u4f8b\u53c2\u8003<\/div>\n<p><a class=\"lbtn\" href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" target=\"_blank\">\u67e5\u770b\u6307\u5357 \u2192<\/a><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/div>\n<\/div>\n<p><!-- \/container --><\/p>\n<p><!-- \u9875\u811a --><\/p>\n<div class=\"footer\">\n<div style=\"font-size:0.76rem;color:rgba(255,255,255,0.6);margin-bottom:6px;\">\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 \u00b7 22\u5e74\u65e5\u7acb\u6388\u6743 \u00b7 2025\u94bb\u77f3\u5b89\u88c5\u5546<\/div>\n<div style=\"font-size:0.72rem;color:rgba(255,255,255,0.35);margin-top:8px;padding-top:8px;border-top:1px solid rgba(255,255,255,0.1);\">\u65b9\u6848\u7f16\u53f7\uff1aLM-20260726-ZNS-DS \u00b7 \u7248\u672c\uff1av15 \u00b7 \u51fa\u5177\u65e5\u671f\uff1a2026-07-26<\/div>\n<div class=\"disc\">* \u5177\u4f53\u8d39\u7528\u56e0\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u800c\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/div>\n<\/div>\n<p><!-- ===== \u96f7\u8fbe\u56feJS ===== --><\/p>\n<p><!-- ===== \u6de1\u5165\u52a8\u753bJS ===== --><\/p>\n<p><!-- ===== JSON-LD\u7ed3\u6784\u5316\u6570\u636e\u56db\u4ef6\u5957\uff08P0\u5fc5\u52a0\uff09 ===== --><\/p>\n<p><script>\n(function(){\n  var c = document.getElementById('radarChart');\n  if(!c) return;\n  var ctx = c.getContext('2d');\n  var W = 500, H = 500, cx = 250, cy = 240, R = 160;\n  var labels = ['\u521d\u6295\u8d44','\u8fd0\u884c\u8d39','\u8212\u9002\u5ea6','\u7a33\u5b9a\u6027','\u7ef4\u62a4\u8d39','\u9759\u97f3\u6027','\u5c42\u9ad8\u53cb\u597d','\u9002\u7528\u6027','\u80fd\u6548'];\n  \/\/ \u65b9\u6848A(\u7eff) \u65b9\u6848B(\u84dd)\n  var dataA = [5, 4, 4, 3, 4, 4, 5, 4, 5];\n  var dataB = [4, 4, 5, 5, 4, 5, 4, 5, 4];\n  var N = labels.length;\n  var angleStep = (Math.PI * 2) \/ N;\n  function drawGrid(){\n    for(var r=1;r<=5;r++){\n      var radius = (R\/5)*r;\n      ctx.beginPath();\n      for(var i=0;i<=N;i++){\n        var a = -Math.PI\/2 + i*angleStep;\n        var x = cx + radius*Math.cos(a), y = cy + radius*Math.sin(a);\n        if(i===0) ctx.moveTo(x,y); else ctx.lineTo(x,y);\n      }\n      ctx.closePath();\n      ctx.strokeStyle = (r===5)?'#CBD5E1':'#E8ECF0';\n      ctx.lineWidth = (r===5)?1:0.5;\n      ctx.stroke();\n    }\n    for(var i=0;i<N;i++){\n      var a = -Math.PI\/2 + i*angleStep;\n      ctx.beginPath(); ctx.moveTo(cx,cy);\n      ctx.lineTo(cx+R*Math.cos(a), cy+R*Math.sin(a));\n      ctx.strokeStyle='#E8ECF0'; ctx.lineWidth=0.5; ctx.stroke();\n    }\n  }\n  function drawLabel(){\n    ctx.font='10px sans-serif'; ctx.textAlign='center'; ctx.textBaseline='middle';\n    for(var i=0;i<N;i++){\n      var a = -Math.PI\/2 + i*angleStep;\n      var lx = cx+(R+22)*Math.cos(a), ly = cy+(R+22)*Math.sin(a);\n      ctx.fillStyle='#003A70'; ctx.fillText(labels[i],lx,ly);\n    }\n  }\n  function drawData(data,color){\n    ctx.beginPath();\n    for(var i=0;i<=N;i++){\n      var idx = i%N, a = -Math.PI\/2+idx*angleStep;\n      var val = data[idx]\/5;\n      var x = cx+R*val*Math.cos(a), y = cy+R*val*Math.sin(a);\n      if(i===0) ctx.moveTo(x,y); else ctx.lineTo(x,y);\n    }\n    ctx.closePath();\n    ctx.fillStyle = color.replace('1)','0.1)');\n    ctx.fill();\n    ctx.strokeStyle = color; ctx.lineWidth=2.5; ctx.stroke();\n  }\n  function legend(){\n    ctx.font='11px sans-serif';\n    var items = [\n      {c:'rgba(39,174,96,1)',l:'\u65b9\u6848\u4e00 \u539f\u59cb\u60f3\u6cd5'},\n      {c:'rgba(0,58,112,1)',l:'\u65b9\u6848\u4e8c \u6027\u4ef7\u6bd4\u63a8\u8350'}\n    ];\n    var lx=120, ly=465;\n    ctx.textAlign='left'; ctx.textBaseline='middle';\n    for(var i=0;i<items.length;i++){\n      ctx.fillStyle=items[i].c; ctx.fillRect(lx,ly,14,14);\n      ctx.fillStyle='#333'; ctx.fillText(items[i].l,lx+20,ly+7);\n      lx+=150;\n    }\n  }\n  ctx.clearRect(0,0,W,H);\n  drawGrid();\n  drawData(dataA,'rgba(39,174,96,1)');\n  drawData(dataB,'rgba(0,58,112,1)');\n  drawLabel();\n  legend();\n})();\n<\/script><\/p>\n<p><script>\n(function(){\n  var sections = document.querySelectorAll('.section');\n  var observer = new IntersectionObserver(function(entries){\n    entries.forEach(function(e){\n      if(e.isIntersecting){\n        e.target.classList.add('visible');\n        observer.unobserve(e.target);\n      }\n    });\n  }, {threshold:0.1});\n  sections.forEach(function(s){\n    s.classList.add('fade-in');\n    observer.observe(s);\n  });\n})();<\/p>\n<p>\/\/ ===== \u7edf\u4e00\u4e8b\u4ef6\u76d1\u542c\uff08\u76f4\u63a5\u63a7\u5236display\uff0cWordPress\u7edd\u5bf9\u62e6\u4e0d\u4f4f\uff09 =====\ndocument.addEventListener('click', function(e){\n  var flip = e.target.closest('.flip-w, .flip-card, .flip-card-type1, .load-flip, .sf-card, .lcc-w');\n  if(flip) {\n    flip.classList.toggle('flipped');\n    \/\/ \u76f4\u63a5\u63a7\u5236\u5185\u8054\u6837\u5f0f\uff08\u5907\u4efd\u65b9\u6848\uff0c\u9632\u6b62CSS\u88ab\u8fc7\u6ee4\uff09\n    var front = flip.querySelector('.flip-f, .sf-front, .lcc-f');\n    var back = flip.querySelector('.flip-b, .sf-back, .lcc-b');\n    if(front && back) {\n      if(flip.classList.contains('flipped')) {\n        front.style.setProperty('display', 'none', 'important');\n        back.style.setProperty('display', 'block', 'important');\n      } else {\n        front.style.display = '';\n        back.style.setProperty('display', 'none', 'important');\n      }\n    }\n    return;\n  }\n  var tog = e.target.closest('.ai-item, .faq-it');\n  if(tog) { tog.classList.toggle('open'); return; }\n});\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"LocalBusiness\",\n  \"name\": \"\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"description\": \"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6210\u90fd\u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546\uff082025\u94bb\u77f3\u5b89\u88c5\u5546\uff09\",\n  \"telephone\": \"028-86131795\",\n  \"address\": {\"@type\": \"PostalAddress\",\"streetAddress\":\"\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\"addressLocality\":\"\u6210\u90fd\",\"addressRegion\":\"\u56db\u5ddd\",\"addressCountry\":\"CN\"},\n  \"url\": \"https:\/\/longmai-nt.com\",\n  \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\"\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\"@type\":\"Question\",\"name\":\"\u5355\u98ce\u6247\u548c\u53cc\u98ce\u6247\u600e\u4e48\u9009\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u53cc\u98ce\u6247\u566a\u97f3\u4f4e2dB(52 vs 54dB)\u3001\u98ce\u91cf\u592717%\u3001\u6563\u70ed\u66f4\u5f3a\uff0c\u4f46\u5916\u673a\u4f4d\u9700\u22651380mm\u5bbd\u3002\u673a\u4f4d\u591f\u5bbd\u63a8\u8350\u53cc\u98ce\u6247\uff0c\u673a\u4f4d\u7a84\u9009\u5355\u98ce\u6247\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"192mm\u5185\u673a\u771f\u7684\u4e0d\u538b\u5c42\u9ad8\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8212\u4eabDC\u5185\u673a\u4ec5192mm\u539a\uff0c\u662f\u65e5\u7acb\u6700\u8584\u7cfb\u5217\u4e4b\u4e00\uff0c\u6700\u4f4e\u53ef\u505a\u5230\u540a\u9876\u5b8c\u6210\u9762\u7ea6250mm\uff0c\u5bf93\u697c\u4f4f\u5b85\u975e\u5e38\u53cb\u597d\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5ba2\u538571+22\u53cc\u5185\u673a\u548c\u535571\u578b\u54ea\u4e2a\u597d\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"71+22\u53cc\u5185\u673a\u5404\u7ba1\u4e00\u7247\u533a\u57df\uff0c46\u33a1\u6a2a\u5385\u6c14\u6d41\u66f4\u5747\u5300\u3001\u8212\u9002\u5ea6\u66f4\u9ad8\u3002\u63a8\u8350\u53cc\u5185\u673a\u65b9\u6848\u3002\"}}\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 \u00b7 \u9f99\u8109\u6696\u901a\",\n  \"author\": {\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\"},\n  \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\"\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"ImageObject\",\n  \"contentUrl\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\n  \"description\": \"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f - \u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97\"\n}\n<\/script><\/p>\n<\/div>\n<p><!-- .entry-content .clear --><\/p>\n<p><!-- #post-## --><\/p>\n<p><script>\n(function(){\nvar flips=document.querySelectorAll(\".sf-card,.flip-w,.lcc-w\");\nflips.forEach(function(f){f.addEventListener(\"click\",function(e){\nif(!e.target.closest(\"a\"))this.classList.toggle(\"flipped\");\n})});\n})();\n<\/script><script>\n(function(){var h=document.querySelectorAll(\".entry-header\");for(var i=0;i<h.length;i++){h[i].style.display=\"none\"}}document.querySelector(\".entry-content\").style.paddingTop=\"0\";\ndocument.querySelector(\".entry-content\").style.marginTop=\"0\";\n})();\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u65b9\u6848\u7f16\u53f7\uff1aLM-20260726-ZNS [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-7721","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 | \u9f99\u8109\u6696\u901a\u00b7\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u5bb6\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b\u900f\u660e\u62a5\u4ef7\u300120\u5e74\u603b\u8d26\u3001\u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f\u3002\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=7721\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 | \u9f99\u8109\u6696\u901a\u00b7\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u5bb6\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b\u900f\u660e\u62a5\u4ef7\u300120\u5e74\u603b\u8d26\u3001\u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f\u3002\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=7721\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-28T13:43:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-fsmbgl-a1je-waiguan.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721\",\"name\":\"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 | \u9f99\u8109\u6696\u901a\u00b7\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-fsmbgl-a1je-waiguan.jpg\",\"datePublished\":\"2026-07-23T02:38:27+00:00\",\"dateModified\":\"2026-07-28T13:43:03+00:00\",\"description\":\"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u5bb6\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b\u900f\u660e\u62a5\u4ef7\u300120\u5e74\u603b\u8d26\u3001\u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f\u3002\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-fsmbgl-a1je-waiguan.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-fsmbgl-a1je-waiguan.jpg\",\"width\":418,\"height\":721},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7721#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5f20\u5973\u58eb\u7a7a\u8c03\u5730\u6696\u65b9\u6848\uff082\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 | \u9f99\u8109\u6696\u901a\u00b7\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03","description":"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u5bb6\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b\u900f\u660e\u62a5\u4ef7\u300120\u5e74\u603b\u8d26\u3001\u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f\u3002\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=7721","og_locale":"zh_CN","og_type":"article","og_title":"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 | \u9f99\u8109\u6696\u901a\u00b7\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03","og_description":"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u5bb6\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b\u900f\u660e\u62a5\u4ef7\u300120\u5e74\u603b\u8d26\u3001\u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f\u3002\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=7721","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-28T13:43:03+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-fsmbgl-a1je-waiguan.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"11 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=7721","url":"https:\/\/longmai-nt.com\/?page_id=7721","name":"\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94+\u5730\u6696\u65b9\u6848 | \u9f99\u8109\u6696\u901a\u00b7\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=7721#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=7721#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-fsmbgl-a1je-waiguan.jpg","datePublished":"2026-07-23T02:38:27+00:00","dateModified":"2026-07-28T13:43:03+00:00","description":"\u6210\u90fd\u5ddd\u5927\u82b1\u56ed\u5f20\u5973\u58eb\u5bb6\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u591a\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b\u900f\u660e\u62a5\u4ef7\u300120\u5e74\u603b\u8d26\u3001\u7cbe\u5de5\u5b89\u88c5\u5b9e\u666f\u3002\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=7721#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=7721"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=7721#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-fsmbgl-a1je-waiguan.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-fsmbgl-a1je-waiguan.jpg","width":418,"height":721},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=7721#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5f20\u5973\u58eb\u7a7a\u8c03\u5730\u6696\u65b9\u6848\uff082\uff09"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7721"}],"version-history":[{"count":82,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7721\/revisions"}],"predecessor-version":[{"id":8597,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7721\/revisions\/8597"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}