{"id":7995,"date":"2026-07-24T15:34:41","date_gmt":"2026-07-24T07:34:41","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=7995"},"modified":"2026-07-26T13:58:55","modified_gmt":"2026-07-26T05:58:55","slug":"%e5%9f%8e%e5%8d%97%e5%ae%98%e9%82%b8-%c2%b7-%e5%85%a8%e5%b1%8b%e6%9a%96%e9%80%9a%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=7995","title":{"rendered":"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66"},"content":{"rendered":"\n\n<!-- ===== \u7ed3\u6784\u5316\u6570\u636e\uff1aArticle \/ FAQPage ===== -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\uff08\u4e09\u65b9\u6848\u5bf9\u6bd4\uff09\",\n      \"description\": \"\u6210\u90fd\u57ce\u5357\u5b98\u90b8\u522b\u5885\uff08\u8d1f2F-4F\u51716\u5c42\uff0c\u91c7\u6696\u9762\u79ef483.6\u33a1\uff0c\u5e38\u4f4f4-5\u4eba\uff09\u5168\u5c4b\u6696\u901a\u4e09\u65b9\u6848\u5bf9\u6bd4\uff1a\u65b9\u6848\u4e00\u6c34\u5885\u9002FX\u4e8c\u8054\u4f9b\uff08\u53cc\u673a\u5e76\u8054\u00b7\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\uff09\uff1b\u65b9\u6848\u4e8c\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff08\u6e29\u6e7f\u53cc\u63a7\u00b7\u81ea\u6e05\u6d01\u00b7\u4e91\u51c0\u65b0\u98ce\uff09\uff1b\u65b9\u6848\u4e09\u5c0a\u777f\u5168\u6548\u4e2d\u592e\u7a7a\u8c03\u3002\u542b\u5206\u7ef4\u5ea6\u8bca\u65ad\u3001\u900f\u660e\u62a5\u4ef7\u3001\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u552e\u540e10\u5e74\u80fd\u6e90\u4fdd\u969c\u3002\",\n      \"author\": { \"@type\": \"Person\", \"name\": \"\u4f59\u6653\u73b2\uff0822\u5e74\u884c\u4e1a\u7ecf\u9a8c\uff09\" },\n      \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"\u9f99\u8109\u6696\u901a\",\n        \"logo\": { \"@type\": \"ImageObject\", \"url\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" }\n      },\n      \"datePublished\": \"2026-07-24\",\n      \"dateModified\": \"2026-07-24\",\n      \"about\": { \"@type\": \"Thing\", \"name\": \"\u522b\u5885\u6696\u901a\u7cfb\u7edf\u4e09\u65b9\u6848\u5bf9\u6bd4\u8bbe\u8ba1\" }\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u57ce\u5357\u5b98\u90b8\u4e09\u5957\u65b9\u6848\u6700\u5927\u7684\u533a\u522b\u662f\u4ec0\u4e48\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u6838\u5fc3\u533a\u522b\u5728\u51b7\u70ed\u6e90\u5f62\u6001\u4e0e\u5730\u4e0b\u5ba4\u9664\u6e7f\u8def\u5f84\uff1a\u65b9\u6848\u4e00\u6c34\u5885\u9002FX\u6c34\u673a\u4e8c\u8054\u4f9b\uff08\u4e24\u53f0\u4e3b\u673a\u5e76\u8054\u3001\u4e00\u7528\u4e00\u5907\u3001\u51fa\u98ce\u67d4\u548c\u4f46\u9700\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u89e3\u51b3\u5730\u4e0b\u5ba4\uff09\uff1b\u65b9\u6848\u4e8c\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff08\u6c1f\u7cfb\u7edf\u7a33\u5b9a\u3001\u81ea\u6e05\u6d01\u3001\u6e29\u6e7f\u53cc\u63a7\u7cbe\u51c6\u9664\u6e7f\u3001\u6c34\u6a21\u5757\u505a\u70ed\u6cf5\u5730\u6696\uff09\uff1b\u65b9\u6848\u4e09\u5c0a\u777f\u5168\u6548\u4e2d\u592e\u7a7a\u8c03\uff08\u914d\u7f6e\u540c\u65b9\u6848\u4e8c\u4f46\u65e0\u6c34\u6a21\u5757\uff0c\u5730\u6696\u5168\u7531\u9505\u7089\u627f\u62c5\uff09\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5730\u4e0b\u5ba4\uff08\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\uff09\u9664\u6e7f\u901a\u98ce\u600e\u4e48\u89e3\u51b3\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u65b9\u6848\u4e00\u91c7\u7528\u65e5\u7acb\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\uff08\u9664\u6e7f+\u65b0\u98ce\u4e00\u4f53\uff0c\u9762\u4ef717,500+\u5b89\u88c57,000\uff09\uff1b\u65b9\u6848\u4e8c\/\u4e09\u91c7\u7528\u5c0a\u777f\u4e09\u7ba1\u5236\u5185\u673a\u5185\u7f6e\u6e29\u6e7f\u53cc\u63a7\u72ec\u7acb\u9664\u6e7f\uff08\u6548\u679c\u4f18\u4e8e\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff09\uff0c\u5730\u4e0b\u5ba4\u4ec5\u9700\u65e5\u7acb\u4e91\u51c0\u666e\u901a\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff08\u9762\u4ef76,200+\u5b89\u88c56,000\uff09\u8d1f\u8d23\u901a\u98ce\u6362\u6c14\u3002\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\u4e0e\u5730\u4e0b\u5ba4\u9632\u6f6e\uff0c\u5c0a\u777f\u5185\u7f6e\u9664\u6e7f\u66f4\u7cbe\u51c6\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5927\u5b85\uff08483\u33a1\u30014-5\u4eba\uff09\u5982\u4f55\u517c\u987e\u8282\u80fd\u4e0e\u9884\u7b97\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u65b9\u6848\u4e00\u6c34\u673a\u53cc\u673a\u5e76\u8054\uff0c\u4eba\u5c11\u65f6\u5355\u53f0\u4f4e\u8d1f\u8377\u8fd0\u884c\u3001\u4eba\u591a\u65f6\u53cc\u673a\u540c\u5f00\uff0c\u4e14\u4e00\u7528\u4e00\u5907\uff1b\u65b9\u6848\u4e8c\u6c34\u6a21\u5757\u4e8c\u8054\u4f9b\u8ba9\u70ed\u6cf5\u53c2\u4e0e\u5730\u6696\uff08COP\u22653\uff0c\u957f\u671f\u7701\u6c14\uff09\u3002\u5730\u6696\u70ed\u6e90\uff1a\u65b9\u6848\u4e00\/\u4e8c\u7531\u6c34\u673a\/\u6c34\u6a21\u5757\u70ed\u6cf5\u627f\u62c5\uff0c\u4e0d\u53e6\u914d\u9505\u7089\uff1b\u4ec5\u65b9\u6848\u4e09\uff08\u65e0\u6c34\u6a21\u5757\uff09\u5730\u6696\u75312\u53f024kW\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5e76\u673a+\u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf179\u5143\/\u33a1\u627f\u62c5\u3002\u603b\u6295\u5165\uff1a\u65b9\u6848\u4e8c270,713\u5143\uff08\u6700\u4f4e\uff09\u3001\u65b9\u6848\u4e00274,748\u5143\u3001\u65b9\u6848\u4e09280,006\u5143\uff08\u6700\u9ad8\uff09\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u54ea\u5957\u65b9\u6848\u7cfb\u7edf\u6700\u7a33\u5b9a\u3001\u7ef4\u62a4\u6700\u7b80\u5355\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5c0a\u777f\u5168\u6548\uff08\u65b9\u6848\u4e8c\/\u4e09\uff09\u4e3a\u6c1f\u7cfb\u7edf\uff0c\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\u3001\u65e0\u6f0f\u6c34\u98ce\u9669\uff0c\u5185\u673a\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc+PE\u51c0\u5316\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\uff1b\u6c34\u5885\u9002\uff08\u65b9\u6848\u4e00\uff09\u4e3a\u5168\u6c34\u7cfb\u7edf\uff0c\u63a5\u5934\u591a\u3001\u9700\u5b9a\u671f\u6e05\u6d17\u8fc7\u6ee4\u5668\u4e0e\u7ba1\u8def\uff0c\u7ef4\u62a4\u9700\u6c42\u76f8\u5bf9\u8f83\u9ad8\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5927\u5b85\uff08483\u33a1\u00b76\u5c42\uff09\u4e3b\u673a\u6545\u969c\u600e\u4e48\u529e\uff1f\u540e\u671f\u7ef4\u62a4\u9891\u7387\u9ad8\u5417\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5197\u4f59\u4e0e\u7ef4\u62a4\u5206\u4e24\u6761\u8def\u5f84\uff1a\u65b9\u6848\u4e00\u6c34\u5885\u9002\u4e3a\u53cc\u673a\u5e76\u8054\u4e00\u7528\u4e00\u5907\uff0c\u5355\u53f0\u6545\u969c\u53e6\u4e00\u53f0\u53ef\u9876\u4e0a\uff0c\u5f71\u54cd\u9762\u53ef\u63a7\uff1b\u65b9\u6848\u4e8c\/\u4e09\u4e3a\u6c1f\u7cfb\u7edf\u5206\u533a\uff08224\u8d1f\u62c5\u8d1f2-1F\u3001280\u8d1f\u62c52-4F\uff09\uff0c\u5355\u53f0\u6545\u969c\u4ec5\u5f71\u54cd\u534a\u5b85\uff0c\u4e14\u6c1f\u7cfb\u7edf\u65e0\u6f0f\u6c34\u98ce\u9669\u3001\u5185\u673a\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\uff0c\u7ef4\u62a4\u9891\u7387\u4f4e\u3002\u6574\u4f53\u5c0a\u777f\u6c1f\u7cfb\u7edf\u7ef4\u62a4\u6700\u7701\u5fc3\uff0c\u6c34\u5885\u9002\u9700\u5b9a\u671f\u6e05\u6d17\u8fc7\u6ee4\u5668\u4e0e\u7ba1\u8def\u3002\u9f99\u8109\u53e6\u63d0\u4f9b10\u5e74\u80fd\u6e90\u4fdd\u969c\u4e0e24\u5c0f\u65f6\u7d27\u6025\u54cd\u5e94\uff0c\u4e3b\u673a\u6545\u969c\u4e0d\u614c\u3002\" }\n        }\n      ]\n    }\n  ]\n}\n<\/script>\n\n<style>\n\/* ===== \u6697\u8272\u91d1 UI \u4f53\u7cfb \u53d8\u91cf ===== *\/\n:root{\n  --lm-bg:#f6f3ec;\n  --lm-bg2:#ffffff;\n  --lm-bg3:#f1ebdc;\n  --lm-bg4:#faf6ec;\n  --lm-gold:#c89b3c;\n  --lm-gold2:#9a7414;\n  --lm-gold3:#b8860b;\n  --lm-on-gold:#2e2616;\n  --lm-text:#3a3326;\n  --lm-text2:#7c7060;\n  --lm-border:#e6dfcd;\n  --lm-red:#c0392b;\n  --lm-green:#3f8f5f;\n  --lm-orange:#c07d2e;\n}\n\n*, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }\nhtml { scroll-behavior: smooth; }\nbody { font-family: -apple-system, \"Microsoft YaHei\", \"PingFang SC\", sans-serif; color: var(--lm-text); background: var(--lm-bg); line-height: 1.8; }\n.entry-title { display: none !important; }\n\n.lm-toc-bar {\n  position: sticky; top: 0; left: 0; right: 0; z-index: 1000;\n  background: rgba(255,255,255,.97); color: var(--lm-text2);\n  display: flex; align-items: center; overflow-x: auto;\n  white-space: nowrap; height: 52px; padding: 0 16px;\n  box-shadow: 0 3px 14px rgba(60,50,30,.16); border-bottom: 2px solid var(--lm-gold);\n  backdrop-filter: blur(8px);\n}\n.lm-toc-bar::-webkit-scrollbar { height: 2px; }\n.lm-toc-bar::-webkit-scrollbar-thumb { background: var(--lm-gold); }\n.lm-toc-item {\n  display: inline-flex; align-items: center; height: 52px;\n  padding: 0 14px; color: var(--lm-text2); text-decoration: none;\n  font-size: 13px; font-weight: 500; letter-spacing: .3px;\n  border-bottom: 2px solid transparent; transition: all .25s; flex-shrink: 0;\n}\n.lm-toc-item:hover { color: var(--lm-text); background: rgba(200,155,60,.10); }\n.lm-toc-item.lm-active { color: var(--lm-gold2); border-bottom-color: var(--lm-gold); background: rgba(200,155,60,.12); }\n\n.lm-container { max-width: 1024px; margin: 16px auto 40px; padding: 0 16px; }\n\n.lm-section {\n  background: var(--lm-bg2); border: 1px solid var(--lm-border); border-radius: 12px;\n  padding: 40px 36px; margin-bottom: 24px; box-shadow: 0 4px 18px rgba(60,50,30,.08); position: relative;\n}\n.lm-section-title {\n  font-size: 22px; font-weight: 700; color: var(--lm-gold2);\n  padding-bottom: 12px; margin-bottom: 24px;\n  border-bottom: 3px solid var(--lm-gold); display: flex; align-items: center; gap: 10px;\n}\n.lm-section-title .lm-num {\n  display: inline-flex; align-items: center; justify-content: center;\n  width: 34px; height: 34px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3));\n  color: var(--lm-on-gold); border-radius: 50%; font-size: 14px; font-weight: 800; flex-shrink: 0;\n}\n\n.lm-table { width: 100%; border-collapse: collapse; margin: 16px 0 20px; font-size: 14px; }\n.lm-table th { background: var(--lm-bg3); color: var(--lm-gold2); padding: 10px 12px; text-align: center; font-weight: 600; border: 1px solid var(--lm-border); }\n.lm-table td { padding: 10px 12px; border: 1px solid var(--lm-border); text-align: center; color: var(--lm-text); }\n.lm-table tr:nth-child(even) td { background: rgba(212,160,23,.04); }\n.lm-table tr:hover td { background: rgba(212,160,23,.10); }\n.lm-table .lm-row-hl td { background: rgba(212,160,23,.12) !important; font-weight: 700; color: var(--lm-gold2); }\n\n.lm-tag { display: inline-block; padding: 2px 10px; border-radius: 4px; font-size: 12px; font-weight: 600; }\n.lm-tag-blue { background: rgba(212,160,23,.18); color: var(--lm-gold2); }\n.lm-tag-green { background: rgba(111,174,133,.18); color: var(--lm-green); }\n.lm-tag-orange { background: rgba(217,154,78,.20); color: var(--lm-orange); }\n.lm-tag-red { background: rgba(192,57,43,.12); color: #c0392b; }\n\n.lm-compare-grid { display: grid; grid-template-columns: 1fr 1fr 1fr; gap: 16px; margin: 20px 0; }\n.lm-compare-card { border-radius: 10px; padding: 22px 18px; border: 2px solid var(--lm-border); position: relative; background: var(--lm-bg2); }\n.lm-compare-card.lm-recommend { border-color: var(--lm-gold); background: rgba(212,160,23,.06); }\n.lm-compare-card .lm-badge { position: absolute; top: -12px; left: 20px; padding: 2px 14px; border-radius: 20px; font-size: 12px; font-weight: 700; color: var(--lm-bg); }\n.lm-badge-rec { background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); }\n.lm-badge-comp { background: #5a4d38; color: #fff; }\n.lm-compare-card h4 { font-size: 15px; margin-bottom: 10px; color: var(--lm-gold2); }\n.lm-compare-card ul { list-style: none; padding: 0; }\n.lm-compare-card li { padding: 5px 0; font-size: 13px; border-bottom: 1px solid var(--lm-border); color: var(--lm-text); }\n.lm-compare-card li:last-child { border-bottom: none; }\n.lm-compare-card li::before { content: \"> \"; color: var(--lm-gold); font-weight: 700; }\n\n.lm-highlight { background: rgba(212,160,23,.10); border-left: 4px solid var(--lm-gold); padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n.lm-highlight-blue { background: rgba(77,140,200,.10); border-left: 4px solid #4d8cc8; padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n.lm-highlight-green { background: rgba(111,174,133,.10); border-left: 4px solid var(--lm-green); padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n\n.lm-info-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)); gap: 12px; margin: 16px 0; }\n.lm-info-item { background: var(--lm-bg3); border: 1px solid var(--lm-border); border-radius: 8px; padding: 14px 16px; text-align: center; }\n.lm-info-item .lm-label { font-size: 12px; color: var(--lm-text2); margin-bottom: 4px; }\n.lm-info-item .lm-value { font-size: 17px; font-weight: 700; color: var(--lm-gold2); }\n\n.lm-step-flow { display: flex; flex-wrap: wrap; gap: 8px; margin: 16px 0; }\n.lm-step-flow .lm-step { background: var(--lm-bg3); border: 1px solid var(--lm-border); padding: 8px 16px; border-radius: 20px; font-size: 13px; color: var(--lm-text2); }\n\n.lm-carousel { position: relative; margin: 18px 0 8px; border-radius: 12px; overflow: hidden; background: var(--lm-bg2); border: 1px solid var(--lm-border); }\n.lm-carousel-track { display: flex; transition: transform .55s cubic-bezier(.4,0,.2,1); }\n.lm-slide { min-width: 100%; }\n.lm-cs-head { display: flex; align-items: center; gap: 12px; padding: 16px 20px; background: linear-gradient(90deg, var(--lm-bg3), var(--lm-bg4)); color: var(--lm-gold2); border-bottom: 1px solid var(--lm-border); }\n.lm-cs-num { background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); font-weight: 800; font-size: 15px; width: 32px; height: 32px; border-radius: 50%; display: flex; align-items: center; justify-content: center; flex-shrink: 0; }\n.lm-cs-title { font-size: 17px; font-weight: 700; }\n.lm-cs-body { padding: 16px 20px 6px; font-size: 14px; line-height: 1.8; color: var(--lm-text); }\n.lm-cs-std { padding: 6px 20px 14px; font-size: 13px; color: var(--lm-gold2); }\n.lm-cs-std b { color: var(--lm-gold2); }\n.lm-cs-imgs { padding: 0 20px 18px; display: flex; gap: 14px; flex-wrap: wrap; align-items: flex-start; }\n.lm-cs-imgs img { width: 300px; height: 210px; object-fit: cover; border-radius: 8px; border: 1px solid var(--lm-border); display: block; }\n.lm-cs-imgs .lm-cap { font-size: 12px; color: var(--lm-text2); margin-top: 4px; text-align: center; }\n.lm-cs-imgs figure { margin: 0; }\n.lm-cs-imgs figure:only-child { flex: 1 1 100%; }\n.lm-cs-imgs figure:only-child img { width: 100%; height: auto; max-height: 480px; object-fit: contain; background: var(--lm-bg3); }\n.lm-car-arrow { position: absolute; top: 50%; transform: translateY(-50%); width: 42px; height: 42px; background: rgba(200,155,60,.88); border: none; border-radius: 50%; font-size: 24px; line-height: 1; color: var(--lm-on-gold); cursor: pointer; display: flex; align-items: center; justify-content: center; transition: all .25s; z-index: 3; box-shadow: 0 2px 8px rgba(0,0,0,.18); }\n.lm-car-arrow:hover { background: var(--lm-gold); }\n.lm-car-arrow.lm-prev { left: 12px; }\n.lm-car-arrow.lm-next { right: 12px; }\n.lm-car-dots { position: absolute; bottom: 12px; left: 0; right: 0; display: flex; gap: 8px; justify-content: center; z-index: 3; }\n.lm-car-dots .lm-dot { width: 9px; height: 9px; border-radius: 50%; background: rgba(154,116,20,.30); cursor: pointer; transition: all .25s; }\n.lm-car-dots .lm-dot.lm-active { background: var(--lm-gold); width: 22px; border-radius: 5px; }\n\n.lm-prod-showcase { display: flex; gap: 16px; flex-wrap: wrap; margin: 18px 0; }\n.lm-prod-card { flex: 0 0 auto; width: 320px; border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; background: var(--lm-bg2); box-shadow: 0 2px 10px rgba(60,50,30,.10); }\n.lm-prod-card img { width: 100%; height: 200px; object-fit: cover; display: block; }\n.lm-prod-card .lm-pc-visual { width: 100%; height: 200px; display: flex; flex-direction: column; align-items: center; justify-content: center; text-align: center; padding: 10px 14px; box-sizing: border-box; }\n.lm-prod-card .lm-pc-visual .v-tag { font-size: 11px; letter-spacing: 1.5px; color: #e8c46a; margin-bottom: 6px; }\n.lm-prod-card .lm-pc-visual .v-name { font-size: 20px; font-weight: 700; color: #fff; margin-bottom: 4px; }\n.lm-prod-card .lm-pc-visual .v-sub { font-size: 12px; color: rgba(255,255,255,.82); }\n.lm-prod-card .lm-pc-body { padding: 12px 14px 14px; }\n.lm-prod-card .lm-pc-title { font-size: 14px; font-weight: 600; color: var(--lm-gold2); margin-bottom: 4px; }\n.lm-prod-card .lm-pc-desc { font-size: 12px; color: var(--lm-text2); margin-bottom: 10px; line-height: 1.6; }\n.lm-prod-card .lm-pc-link { display: inline-block; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); font-size: 13px; font-weight: 600; padding: 6px 16px; border-radius: 20px; text-decoration: none; }\n.lm-prod-card .lm-pc-link:hover { background: var(--lm-gold2); }\n\n.lm-tabs-nav { display: flex; gap: 0; margin: 18px 0 0; border-bottom: 2px solid var(--lm-border); flex-wrap: wrap; }\n.lm-tab-btn { background: var(--lm-bg3); color: var(--lm-text2); border: 1px solid var(--lm-border); border-bottom: none; padding: 10px 22px; font-size: 14px; font-weight: 600; cursor: pointer; transition: all .25s; border-radius: 8px 8px 0 0; margin-right: 4px; }\n.lm-tab-btn:hover { color: var(--lm-gold2); }\n.lm-tab-btn.lm-active { background: var(--lm-gold); color: var(--lm-on-gold); border-color: var(--lm-gold); }\n.lm-tab-panel { display: none; padding: 8px 0; }\n.lm-tab-panel.lm-active { display: block; animation: lmFade .3s; }\n@keyframes lmFade { from { opacity: 0; } to { opacity: 1; } }\n\n.lm-acc { margin: 16px 0; border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; }\n.lm-acc-item { border-bottom: 1px solid var(--lm-border); }\n.lm-acc-item:last-child { border-bottom: none; }\n.lm-acc-head { display: flex; align-items: center; justify-content: space-between; padding: 14px 18px; background: var(--lm-bg3); cursor: pointer; font-size: 15px; font-weight: 600; color: var(--lm-gold2); transition: background .2s; user-select: none; }\n.lm-acc-head:hover { background: var(--lm-bg4); }\n.lm-acc-head .lm-acc-ico { color: var(--lm-gold); font-size: 18px; transition: transform .3s; }\n.lm-acc-item.lm-open .lm-acc-head .lm-acc-ico { transform: rotate(45deg); }\n.lm-acc-body { max-height: 0; overflow: hidden; transition: max-height .4s ease; background: var(--lm-bg2); }\n.lm-acc-item.lm-open .lm-acc-body { max-height: 1400px; }\n.lm-acc-body-inner { padding: 4px 18px 18px; }\n\n.lm-chart-box { background: var(--lm-bg2); border: 1px solid var(--lm-border); border-radius: 10px; padding: 16px; margin: 20px 0; }\n.lm-chart-box .lm-chart-title { font-size: 15px; font-weight: 600; color: var(--lm-gold2); margin-bottom: 10px; }\n.lm-chart { width: 100%; height: 380px; }\n\n.lm-flip-card { perspective: 1400px; margin: 20px 0; cursor: pointer; }\n.lm-flip-inner { position: relative; width: 100%; height: 520px; transition: transform .6s; transform-style: preserve-3d; }\n.lm-flip-card.lm-flip-open .lm-flip-inner { transform: rotateY(180deg); }\n.lm-flip-front, .lm-flip-back { position: absolute; top:0; left:0; width:100%; height:100%; -webkit-backface-visibility: hidden; backface-visibility: hidden; background: var(--lm-bg2); border:1px solid var(--lm-border); border-radius:10px; padding:16px; box-sizing:border-box; overflow-y:auto; }\n.lm-flip-back { transform: rotateY(180deg); }\n.lm-flip-tag { font-size:13px; font-weight:600; color:var(--lm-gold2); margin-bottom:8px; }\n.lm-flip-hint { font-size:12px; color:var(--lm-text2); text-align:center; margin-top:8px; }\n\n.lm-case-link { color: var(--lm-gold2); font-weight: 600; text-decoration: none; border-bottom: 1px dashed var(--lm-gold); }\n.lm-case-link:hover { color: var(--lm-gold); border-bottom-color: var(--lm-gold2); }\n.lm-case-link::after { content: \" \u2197\"; font-size: 11px; color: var(--lm-gold); }\n\n.lm-img-row { display: flex; gap: 16px; margin: 20px 0; flex-wrap: wrap; }\n.lm-img-row .lm-img-card { flex: 1; min-width: 200px; border-radius: 10px; overflow: hidden; box-shadow: 0 2px 10px rgba(60,50,30,.10); background: var(--lm-bg2); text-align: center; border: 1px solid var(--lm-border); }\n.lm-img-row .lm-img-card img { width: 100%; height: auto; display: block; }\n.lm-img-row .lm-img-card .lm-img-label { padding: 8px 10px; font-size: 13px; color: var(--lm-gold2); background: var(--lm-bg3); border-top: 1px solid var(--lm-border); }\n\n.lm-cover {\n  text-align: center; padding: 90px 36px 80px; position: relative; overflow: hidden;\n  color: #fff;\n  background-image:\n    linear-gradient(135deg, rgba(20,16,8,.80) 0%, rgba(40,30,15,.58) 50%, rgba(20,16,8,.82) 100%),\n    url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p09-04.jpeg');\n  background-size: cover; background-position: center center; background-repeat: no-repeat;\n  min-height: 480px; display: flex; flex-direction: column; justify-content: center;\n  border: 1px solid var(--lm-border); border-radius: 12px; margin-bottom: 24px; box-shadow: 0 4px 18px rgba(0,0,0,.35);\n}\n.lm-cover::before { content: \"\"; position: absolute; top: 0; left: 0; right: 0; height: 6px; z-index: 2; background: linear-gradient(90deg, var(--lm-gold), var(--lm-gold2), var(--lm-gold)); }\n.lm-cover::after { content: \"\"; position: absolute; bottom: 0; left: 0; right: 0; height: 80px; background: linear-gradient(180deg, transparent, rgba(20,16,8,.6)); pointer-events: none; }\n.lm-cover > * { position: relative; z-index: 1; }\n.lm-cover h1 { font-size: 36px; color: #fff; margin-bottom: 12px; text-shadow: 0 2px 12px rgba(0,0,0,.7); letter-spacing: 1px; }\n.lm-cover .lm-sub { font-size: 19px; color: #e8dcc0; margin-bottom: 24px; text-shadow: 0 1px 6px rgba(0,0,0,.6); font-weight: 300; }\n.lm-cover .lm-meta { display: flex; justify-content: center; gap: 28px; flex-wrap: wrap; font-size: 14px; color: #d8c8a8; margin-top: 20px; }\n.lm-cover .lm-meta span { background: rgba(212,160,23,.14); padding: 6px 14px; border-radius: 20px; backdrop-filter: blur(4px); border: 1px solid rgba(212,160,23,.35); }\n.lm-cover .lm-meta .lm-brand-tag { background: rgba(212,160,23,.22); color: var(--lm-gold2); font-weight: 600; border: 1px solid rgba(212,160,23,.5); }\n\n.lm-contact-footer { padding: 0; }\n.lm-cf-header { text-align: center; padding: 32px 24px 20px; border-bottom: 1px solid var(--lm-border); }\n.lm-cf-header .lm-cf-title { font-size: 22px; font-weight: 700; color: var(--lm-gold2); display: flex; align-items: center; justify-content: center; gap: 8px; }\n.lm-cf-header .lm-cf-title .lm-phone-icon { color: var(--lm-gold); font-size: 24px; }\n.lm-cf-header .lm-cf-sub { font-size: 14px; color: var(--lm-text2); margin-top: 8px; }\n.lm-cf-contacts { display: grid; grid-template-columns: repeat(4, 1fr); gap: 12px; padding: 20px 24px; }\n.lm-cf-contact { display: flex; align-items: center; gap: 10px; padding: 12px 16px; border: 1px solid var(--lm-border); border-radius: 8px; background: var(--lm-bg3); transition: all .25s; text-decoration: none; }\n.lm-cf-contact:hover { border-color: var(--lm-gold); background: rgba(212,160,23,.08); }\n.lm-cf-contact .lm-ic { width: 32px; height: 32px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); border-radius: 8px; display: flex; align-items: center; justify-content: center; font-size: 16px; flex-shrink: 0; }\n.lm-cf-contact .lm-info { display: flex; flex-direction: column; }\n.lm-cf-contact .lm-label { font-size: 12px; color: var(--lm-text2); }\n.lm-cf-contact .lm-phone { font-size: 15px; font-weight: 700; color: var(--lm-gold2); }\n.lm-cf-services { display: grid; grid-template-columns: repeat(4, 1fr); gap: 8px; padding: 0 24px 20px; }\n.lm-cf-service { display: flex; align-items: center; gap: 6px; padding: 8px 12px; background: var(--lm-bg3); border-radius: 6px; font-size: 13px; color: var(--lm-text); }\n.lm-cf-service .lm-ck { color: var(--lm-green); font-weight: 700; font-size: 14px; }\n.lm-cf-stores { display: grid; grid-template-columns: 1fr 1fr; gap: 16px; padding: 0 24px 20px; }\n.lm-cf-store { border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; background: var(--lm-bg2); }\n.lm-cf-store .lm-store-label { padding: 8px 14px; background: var(--lm-bg3); font-size: 14px; font-weight: 600; color: var(--lm-gold2); display: flex; align-items: center; gap: 6px; border-bottom: 1px solid var(--lm-border); }\n.lm-cf-store .lm-store-label .lm-pin { color: var(--lm-gold); }\n.lm-cf-store img { width: 100%; height: 200px; object-fit: cover; display: block; }\n.lm-cf-store .lm-store-addr { padding: 10px 14px; font-size: 13px; color: var(--lm-text2); display: flex; gap: 6px; align-items: flex-start; }\n.lm-cf-store .lm-store-addr .lm-pin { color: var(--lm-gold); flex-shrink: 0; }\n.lm-cf-service-area { text-align: center; padding: 16px 24px; font-size: 13px; color: var(--lm-text); border-top: 1px solid var(--lm-border); border-bottom: 1px solid var(--lm-border); background: var(--lm-bg3); }\n.lm-cf-service-area .lm-label { font-weight: 600; color: var(--lm-gold2); margin-right: 8px; }\n.lm-cf-cta { text-align: center; padding: 24px; }\n.lm-cf-cta .lm-btn { display: inline-flex; align-items: center; gap: 6px; padding: 12px 36px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); border-radius: 30px; font-size: 15px; font-weight: 700; text-decoration: none; box-shadow: 0 4px 14px rgba(200,155,60,.30); transition: all .25s; }\n.lm-cf-cta .lm-btn:hover { background: var(--lm-gold2); transform: translateY(-1px); }\n.lm-cf-footer-note { text-align: center; padding: 12px 24px 24px; font-size: 12px; color: var(--lm-text2); }\n\na[href*=\"\/\/\"]:not([href*=\"longmai-nt.com\"]) { color: var(--lm-red); text-decoration: underline; }\n\n@media (max-width: 768px) {\n  .lm-cf-contacts, .lm-cf-services { grid-template-columns: 1fr 1fr; }\n  .lm-cf-stores { grid-template-columns: 1fr; }\n  .lm-cf-store img { height: 160px; }\n  .lm-compare-grid { grid-template-columns: 1fr; }\n  .lm-container { margin-top: 16px; padding: 0 10px; }\n  .lm-section { padding: 24px 16px; }\n  .lm-cover h1 { font-size: 22px; }\n  .lm-toc-item { padding: 0 10px; font-size: 12px; }\n  .lm-table { font-size: 12px; }\n  .lm-table th, .lm-table td { padding: 6px 8px; }\n  .lm-info-grid { grid-template-columns: 1fr 1fr; }\n  .lm-cs-imgs img { width: 200px; height: 140px; }\n  .lm-cs-imgs figure:only-child img { width: 100%; height: auto; max-height: 320px; object-fit: contain; }\n}\n\n\/* ===== \u9879\u76ee\u4fe1\u606f\u5361\u00b7\u7ffb\u8f6c\u5361 ===== *\/\n.lm-info-flip-grid { display:grid; grid-template-columns:repeat(3,1fr); gap:14px; }\n.lm-info-flip { perspective:1000px; height:96px; }\n.lm-info-flip-inner { position:relative; width:100%; height:100%; transition:transform .6s; transform-style:preserve-3d; }\n.lm-info-flip:hover .lm-info-flip-inner { transform:rotateY(180deg); }\n.lm-info-flip-face { position:absolute; inset:0; backface-visibility:hidden; border:1px solid var(--lm-border); border-radius:10px; background:var(--lm-bg2); display:flex; flex-direction:column; align-items:center; justify-content:center; padding:10px; text-align:center; box-shadow:0 2px 10px rgba(60,50,30,.06); }\n.lm-info-flip-front .lm-label { font-size:12px; color:var(--lm-text2); margin-bottom:6px; }\n.lm-info-flip-front .lm-value { font-size:17px; font-weight:700; color:var(--lm-gold2); }\n.lm-info-flip-back { transform:rotateY(180deg); background:linear-gradient(135deg,var(--lm-bg3),var(--lm-bg4)); }\n.lm-info-flip-back .lm-detail { font-size:12px; color:var(--lm-text); line-height:1.5; }\n@media(max-width:640px){ .lm-info-flip-grid{ grid-template-columns:repeat(2,1fr);} }\n\n\/* ===== \u516d\u7ef4\u5ea6\u8bc4\u5206\u00b7\u7ffb\u8f6c\u5361 ===== *\/\n.lm-score-grid { display:grid; grid-template-columns:repeat(3,1fr); gap:16px; margin:18px 0; }\n.lm-score-card { perspective:1000px; height:184px; cursor:pointer; }\n.lm-score-inner { position:relative; width:100%; height:100%; transition:transform .6s; transform-style:preserve-3d; }\n.lm-score-card:hover .lm-score-inner { transform:rotateY(180deg); }\n.lm-score-face { position:absolute; inset:0; backface-visibility:hidden; border-radius:12px; padding:16px; border:1px solid var(--lm-border); background:var(--lm-bg2); box-shadow:0 2px 10px rgba(60,50,30,.08); display:flex; flex-direction:column; }\n.lm-score-front { align-items:center; justify-content:center; text-align:center; }\n.lm-score-dim { font-size:15px; font-weight:700; color:var(--lm-gold2); margin-bottom:12px; }\n.lm-score-bars { width:100%; }\n.lm-score-row { display:flex; align-items:center; gap:6px; font-size:11px; color:var(--lm-text2); margin:4px 0; }\n.lm-score-row .lm-sname { width:52px; text-align:right; flex-shrink:0; }\n.lm-score-row .lm-sbar { flex:1; height:8px; border-radius:4px; background:var(--lm-bg3); overflow:hidden; }\n.lm-score-row .lm-sfill { display:block; height:100%; border-radius:4px; }\n.lm-score-back { transform:rotateY(180deg); background:linear-gradient(135deg,#2e2616,#3a3326); color:#e8dcc0; }\n.lm-score-back .lm-score-dim { color:var(--lm-gold); }\n.lm-score-back ul { margin:4px 0 0; padding-left:16px; font-size:12px; line-height:1.6; }\n@media(max-width:640px){ .lm-score-grid{ grid-template-columns:repeat(2,1fr);} .lm-score-card{height:210px;} }\n\n\/* ===== \u4e86\u89e3\u66f4\u591a ===== *\/\n.lm-more-grid { display:grid; grid-template-columns:repeat(2,1fr); gap:16px; margin:16px 0; }\n.lm-more-card { display:flex; gap:14px; align-items:center; padding:18px; border:1px solid var(--lm-border); border-radius:12px; background:var(--lm-bg2); text-decoration:none; transition:all .25s; }\n.lm-more-card:hover { border-color:var(--lm-gold); box-shadow:0 4px 16px rgba(200,155,60,.18); transform:translateY(-2px); }\n.lm-more-ico { width:46px; height:46px; border-radius:10px; background:linear-gradient(135deg,var(--lm-gold),var(--lm-gold2)); color:#fff; display:flex; align-items:center; justify-content:center; font-size:20px; flex-shrink:0; }\n.lm-more-t { color:var(--lm-text); }\n.lm-more-t b { display:block; color:var(--lm-gold2); font-size:15px; margin-bottom:2px; }\n.lm-more-t span { font-size:12px; color:var(--lm-text2); }\n@media(max-width:640px){ .lm-more-grid{ grid-template-columns:1fr; } }\n\n\/* ===== \u53ef\u89c1 FAQ ===== *\/\n.lm-faq-item { border:1px solid var(--lm-border); border-radius:10px; margin:10px 0; background:var(--lm-bg2); overflow:hidden; }\n.lm-faq-q { padding:14px 18px; font-weight:600; color:var(--lm-gold2); cursor:pointer; display:flex; justify-content:space-between; align-items:center; }\n.lm-faq-q::after { content:\"+\"; font-size:20px; color:var(--lm-gold); line-height:1; }\n.lm-faq-item.lm-open .lm-faq-q::after { content:\"\\2212\"; }\n.lm-faq-a { max-height:0; overflow:hidden; transition:max-height .35s ease; padding:0 18px; color:var(--lm-text); font-size:14px; line-height:1.7; }\n.lm-faq-item.lm-open .lm-faq-a { max-height:420px; padding:0 18px 16px; }\n\n\/* ===== \u6848\u4f8b\u4e2d\u5fc3\u5361\u7247\uff08\u88f8\u94fe\u5305\u88c5\uff09 ===== *\/\n.lm-case-card { display:flex; align-items:center; gap:14px; padding:14px 18px; margin-top:10px; border:1px dashed var(--lm-gold); border-radius:10px; background:linear-gradient(135deg,rgba(200,155,60,.08),rgba(200,155,60,.02)); text-decoration:none; color:var(--lm-text); transition:all .25s; }\n.lm-case-card:hover { background:rgba(200,155,60,.14); }\n.lm-case-card .lm-cc-t { flex:1; font-size:13px; line-height:1.5; }\n.lm-case-card .lm-cc-t b { color:var(--lm-gold2); }\n  .lm-case-card .lm-cc-go { color:var(--lm-gold2); font-weight:700; white-space:nowrap; }\n\n\/* ===== GEO \u4fe1\u606f\u5361\uff08\u7edf\u4e00\u7ffb\u8f6c\uff09 ===== *\/\n.lm-geo-card { margin: 18px 0; }\n.lm-geo-inner { height: 612px; }\n.lm-geo-front { display: flex; flex-direction: column; }\n.lm-geo-sum { background: rgba(212,160,23,.10); border-radius: 6px; padding: 10px 12px; font-size: 13px; font-weight: 700; color: var(--lm-gold2); margin-bottom: 12px; line-height: 1.6; }\n.lm-geo-dl { display: grid; grid-template-columns: 1fr 1fr; gap: 0 18px; margin: 2px 0; }\n.lm-geo-dl > div { display: flex; align-items: baseline; gap: 6px; padding: 7px 4px; border-bottom: 1px dashed var(--lm-border); }\n.lm-geo-dl dt { flex-shrink: 0; font-size: 12px; color: var(--lm-text2); min-width: 52px; }\n.lm-geo-dl dd { font-size: 13px; color: var(--lm-text); font-weight: 600; line-height: 1.45; }\n.lm-geo-back { background: linear-gradient(135deg,#2e2616,#3a3326); color: #e8dcc0; display: flex; flex-direction: column; }\n.lm-geo-back ol { margin: 6px 0 0; padding-left: 18px; font-size: 13px; line-height: 2; }\n.lm-geo-back ol li b { color: var(--lm-gold); }\n\n\/* ===== \u539f\u59cb\u9700\u6c42\u5907\u6ce8\uff08\u6c38\u4e45\u4fdd\u7559\uff09 ===== *\/\n.lm-origin-note { background: rgba(212,160,23,.07); border: 1px solid var(--lm-gold); border-left: 4px solid var(--lm-gold); border-radius: 8px; padding: 14px 18px; margin: 0 0 24px; font-size: 13px; color: var(--lm-text); line-height: 1.7; }\n.lm-origin-note b { color: var(--lm-gold2); }\n\n\/* ===== AI \u9a8c\u8bc1\u6e05\u5355 ===== *\/\n.lm-checklist { list-style: none; padding: 0; margin: 0; }\n.lm-checklist li { padding: 9px 0; font-size: 13px; color: var(--lm-text); border-bottom: 1px dashed var(--lm-border); line-height: 1.75; }\n.lm-checklist li:last-child { border-bottom: none; }\n.lm-checklist .lm-ck-ico { color: var(--lm-green); font-weight: 700; margin-right: 6px; }\n<\/style>\n\n<!-- ========== \u56fa\u5b9a\u5bfc\u822a ========== -->\n<nav class=\"lm-toc-bar\">\n  <a class=\"lm-toc-item lm-active\" href=\"#cover\">\u5c01\u9762<\/a>\n  <a class=\"lm-toc-item\" href=\"#s1\">S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/a>\n  <a class=\"lm-toc-item\" href=\"#s2\">S2\u00b7\u65b9\u6848\u8bca\u65ad<\/a>\n  <a class=\"lm-toc-item\" href=\"#s3\">S3\u00b7\u7cfb\u7edf\u8bbe\u8ba1<\/a>\n  <a class=\"lm-toc-item\" href=\"#s4\">S4\u00b7\u900f\u660e\u62a5\u4ef7<\/a>\n  <a class=\"lm-toc-item\" href=\"#s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1<\/a>\n  <a class=\"lm-toc-item\" href=\"#sa\">\u9644\u5f55\u00b7\u54c1\u724c\u6388\u6743<\/a>\n  <a class=\"lm-toc-item\" href=\"#more\">\u4e86\u89e3\u66f4\u591a<\/a>\n  <a class=\"lm-toc-item\" href=\"#faq\">\u5e38\u89c1\u95ee\u9898<\/a>\n  <a class=\"lm-toc-item\" href=\"#s10\">\u8054\u7cfb\u6211\u4eec<\/a>\n<\/nav>\n\n<div class=\"lm-container\">\n\n<!-- ===== \u5c01\u9762 ===== -->\n<section class=\"lm-section lm-cover\" id=\"cover\">\n  <h1>\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66<\/h1>\n  <p class=\"lm-sub\">\u4e09\u5957\u65b9\u6848\u5bf9\u6bd4 \u00b7 \u8212\u9002\u5065\u5eb7 \u00b7 \u8282\u80fd\u7a33\u5b9a \u00b7 \u9884\u7b97\u53ef\u63a7<\/p>\n  <div class=\"lm-meta\">\n    <span>\u5ba2\u6237\uff1a\u6731\u8001\u5e08<\/span>\n    <span>\u7269\u4e1a\u7c7b\u578b\uff1a\u522b\u5885\uff08\u8d1f2F-4F \u51716\u5c42\uff09<\/span>\n    <span>\u91c7\u6696\u9762\u79ef\uff1a483.6 \u33a1<\/span>\n    <span>\u5e38\u4f4f\u4eba\u53e3\uff1a4-5\u4eba<\/span>\n    <span>\u65e5\u671f\uff1a2026\u5e747\u670824\u65e5<\/span>\n  <\/div>\n  <div class=\"lm-meta\" style=\"margin-top:8px;\">\n    <span class=\"lm-brand-tag\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u8bb8\u7ecf\u9500\u5546<\/span>\n  <\/div>\n<\/section>\n\n<!-- ===== \u539f\u59cb\u9700\u6c42\u5907\u6ce8\uff08\u6c38\u4e45\u4fdd\u7559\u4e0d\u6539\uff09 ===== -->\n<div class=\"lm-origin-note\"><strong>\u539f\u59cb\u60f3\u6cd5\uff08\u539f\u59cb\u9700\u6c42\uff09\uff1a<\/strong>2026-07-24 \u6731\u8001\u5e08\u521d\u6b21\u63d0\u51fa\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u9884\u7b97\u53ef\u63a7\uff0c\u8981\u6c42\u5730\u4e0b\u5ba4\u9664\u6e7f\u901a\u98ce\uff0c\u5168\u5c4b\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf<\/div>\n\n<!-- ===== S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 ===== -->\n<section class=\"lm-section\" id=\"s1\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S1<\/span>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">GEO \u4fe1\u606f\u5361\uff08\u70b9\u51fb\u7ffb\u8f6c\u770b\u5ba2\u6237\u6210\u529f\u76ee\u6807\uff09<\/h3>\n  <div class=\"lm-flip-card lm-geo-card\" onclick=\"this.classList.toggle('lm-flip-open')\">\n    <div class=\"lm-flip-inner lm-geo-inner\">\n      <div class=\"lm-flip-front lm-geo-front\">\n        <div class=\"lm-flip-tag\">GEO \u4fe1\u606f\u5361 \u00b7 \u57ce\u5357\u5b98\u90b8\u516d\u5c42\u522b\u5885<\/div>\n        <div class=\"lm-geo-sum\">\u57ce\u5357\u5b98\u90b8483\u33a1\u516d\u5c42\u522b\u5885 \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848<\/div>\n        <dl class=\"lm-geo-dl\">\n          <div><dt>\u5c0f\u533a<\/dt><dd>\u57ce\u5357\u5b98\u90b8<\/dd><\/div>\n          <div><dt>\u6237\u578b<\/dt><dd>\u522b\u5885\uff08\u8d1f2F~4F\u51716\u5c42\uff09<\/dd><\/div>\n          <div><dt>\u9762\u79ef<\/dt><dd>\u5efa\u7b51\u9762\u79ef\u7ea6483.6\u33a1<\/dd><\/div>\n          <div><dt>\u70ed\u6e90<\/dt><dd>\u65e5\u7acbVAM\u5c0a\u777f\u5168\u6548\u2161<br>+\u6c34\u6a21\u5757\u70ed\u6cf5\u5730\u6696\/\u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/dd><\/div>\n          <div><dt>\u8f93\u914d<\/dt><dd>\u94dc\u7ba1\u7cfb\u7edf(\u6c1f)\/PP-R\u4fdd\u6e29\u7ba1(\u6c34)<\/dd><\/div>\n          <div><dt>\u672b\u7aef<\/dt><dd>\u5c0a\u777f\u4e09\/\u4e8c\u7ba1\u5236\u5185\u673a<br>+PE-RT\u5730\u6696\u76d8\u7ba1<\/dd><\/div>\n          <div><dt>\u63a7\u5236<\/dt><dd>\u65e5\u7acb\u539f\u5382\u6e29\u63a7\u5668<\/dd><\/div>\n          <div><dt>\u65bd\u5de5\u65b9<\/dt><dd>\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u8bb8\u7ecf\u9500\u5546<\/dd><\/div>\n          <div><dt>\u57ce\u5e02<\/dt><dd>\u6210\u90fd<\/dd><\/div>\n          <div><dt>\u65b9\u6848\u7f16\u53f7<\/dt><dd>LM-20260724-FA01<\/dd><\/div>\n        <\/dl>\n        <div class=\"lm-flip-hint\">\u21bb \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n      <\/div>\n      <div class=\"lm-flip-back lm-geo-back\">\n        <div class=\"lm-flip-tag\">\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n        <ol>\n          <li><b>\u8212\u9002\u5065\u5eb7\uff1a<\/b>\u5168\u5c4b\u6e29\u6e7f\u53cc\u63a7\uff0c\u5730\u4e0b\u5ba4\u6885\u96e8\u5b63\u4e0d\u8fd4\u6f6e<\/li>\n          <li><b>\u8282\u80fd\u7701\u94b1\uff1a<\/b>\u70ed\u6cf5\u5730\u6696\u957f\u671f\u7701\u6c14\uff0c20\u5e74\u8fd0\u884c\u8d39\u6700\u4f4e<\/li>\n          <li><b>\u7cfb\u7edf\u7a33\u5b9a\uff1a<\/b>\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u5bc6\u5c01\u65e0\u6f0f\u6c34\u98ce\u9669<\/li>\n          <li><b>\u9884\u7b97\u53ef\u63a7\uff1a<\/b>\u521d\u6295270,713\u5143\u6027\u4ef7\u6bd4\u6700\u4f18<\/li>\n        <\/ol>\n        <div class=\"lm-flip-hint\">\u21bb \u70b9\u51fb\u7ffb\u8f6c\u56de\u4fe1\u606f\u5361<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u6838\u5fc3\u8bc9\u6c42<\/h3>\n  <div class=\"lm-highlight\"><strong>\u6731\u8001\u5e08\u8981\u6c42\uff1a<\/strong>\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\uff0c\u53c8\u8981\u63a7\u5236\u9884\u7b97\uff1b\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\u5e0c\u671b\u9664\u6e7f\u901a\u98ce\uff0c\u6574\u4f53\u7cfb\u7edf\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\uff0c\u4e14\u9884\u7b97\u53ef\u63a7\u3002<\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u8bca\u65ad\u5206\u6790<\/h3>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:22%;\">\u75db\u70b9\/\u95ee\u9898<\/th><th style=\"width:38%;\">\u8868\u73b0<\/th><th style=\"width:40%;\">\u5e94\u5bf9\u7b56\u7565<\/th><\/tr>\n    <tr><td>\u5927\u5b85\u51b7\u91cf\u5339\u914d<\/td><td>483\u33a1\u516d\u5c42\u5927\u5b85\uff0c\u5e38\u9a7b4-5\u4eba\uff0c occupancy \u6ce2\u52a8\u5927<\/td><td>\u5206\u4e24\u5957\u4e3b\u673a\u5206\u533a\u63a7\u5236\uff08\u5730\u4e0b\u5ba4+\u4f4e\u5c42 \/ \u9ad8\u5c42\uff09\uff0c\u907f\u514d\u5927\u9a6c\u62c9\u5c0f\u8f66<\/td><\/tr>\n    <tr><td>\u5730\u4e0b\u5ba4\u9664\u6e7f\u901a\u98ce<\/td><td>\u8d1f1F\u8d1f2F\u6f6e\u6e7f\u3001\u65e0\u81ea\u7136\u901a\u98ce\uff0c\u6885\u96e8\u5b63\u6613\u53d1\u9709<\/td><td>\u65b9\u6848\u4e00\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\uff1b\u65b9\u6848\u4e8c\/\u4e09\u7528\u5c0a\u777f\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u7f6e\u9664\u6e7f+\u4e91\u51c0\u65b0\u98ce<\/td><\/tr>\n    <tr><td>\u8212\u9002\u5065\u5eb7<\/td><td>\u5bb6\u5ead\u6709\u8001\u4eba\u5c0f\u5b69\uff0c\u5173\u6ce8\u7a7a\u6c14\u54c1\u8d28\u4e0e\u51fa\u98ce\u67d4\u548c<\/td><td>\u5c0a\u777fPE\u51c0\u5316+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff1b\u6c34\u673a\u51fa\u98ce\u66f4\u67d4\u548c\uff08\u65b9\u6848\u4e00\uff09<\/td><\/tr>\n    <tr><td>\u8282\u80fd\u4e0e\u9884\u7b97<\/td><td>\u957f\u671f\u8fd0\u884c\u8d39\u7528\u654f\u611f\uff0c\u5e0c\u671b\u521d\u671f\u6295\u5165\u53ef\u63a7<\/td><td>\u6c34\u673a\u53cc\u673a\u5e76\u673a\u6309\u9700\u542f\u505c\uff1b\u5c0a\u777f\u6c34\u6a21\u5757\u70ed\u6cf5\u5730\u6696\u7701\u6c14\uff1b\u5730\u6696\u70ed\u6e90\uff1a\u65b9\u6848\u4e00\/\u4e8c\u7531\u70ed\u6cf5\u627f\u62c5\uff08\u4e0d\u914d\u9505\u7089\uff09\uff0c\u4ec5\u65b9\u6848\u4e09\u914d\u83f2\u65af\u66fc\u9505\u7089<\/td><\/tr>\n    <tr><td>\u7cfb\u7edf\u7a33\u5b9a\u5197\u4f59<\/td><td>\u5927\u5b85\u4e00\u65e6\u4e3b\u673a\u6545\u969c\u5f71\u54cd\u9762\u5e7f<\/td><td>\u65b9\u6848\u4e00\u6c34\u673a\u53cc\u673a\u4e00\u7528\u4e00\u5907\uff1b\u65b9\u6848\u4e8c\/\u4e09\u6c1f\u7cfb\u7edf\u7a33\u5b9a\u3001\u6545\u969c\u7387\u4f4e<\/td><\/tr>\n    <tr><td>\u7ef4\u62a4\u7b80\u4fbf<\/td><td>\u5e0c\u671b\u540e\u671f\u7ef4\u62a4\u7701\u5fc3<\/td><td>\u5c0a\u777f\u6c1f\u7cfb\u7edf\u81ea\u6e05\u6d01+\u94dc\u7ba1\u6807\u51c6\u5316\uff0c\u7ef4\u62a4\u7b80\u5355\uff1b\u6c34\u673a\u9700\u5b9a\u671f\u6e05\u6d17<\/td><\/tr>\n  <\/table>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u5730\u4e0b\u5ba4\uff08\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\uff09\u65b9\u6848\u5206\u6790<\/h3>\n  <div class=\"lm-highlight-blue\">\n    <strong>\u5173\u4e8e\u5730\u4e0b\u5ba4\u9664\u6e7f\u901a\u98ce\u7684\u4e24\u79cd\u8def\u5f84\uff1a<\/strong><br>\n    <strong>\u8def\u5f84A\uff08\u65b9\u6848\u4e00\uff09\uff1a<\/strong>\u6c34\u5885\u9002\u4e3a\u5929\u6c34\u5730\u6c34\u7cfb\u7edf\uff0c\u7a7a\u8c03\u672c\u8eab\u9664\u6e7f\u80fd\u529b\u5f31\uff0c\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\u9700\u5355\u72ec\u914d\u7f6e<strong>\u65e5\u7acb\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350<\/strong>\uff08\u9664\u6e7f+\u65b0\u98ce\u4e00\u4f53\uff0c\u9762\u4ef717,500+\u5b89\u88c57,000\uff09\uff0c\u89e3\u51b3\u5730\u4e0b\u5ba4\u6f6e\u6e7f\u4e0e\u6362\u6c14\u3002<br>\n    <strong>\u8def\u5f84B\uff08\u65b9\u6848\u4e8c\/\u4e09\uff09\uff1a<\/strong>\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\u5185\u7f6e<strong>\u6e29\u6e7f\u53cc\u63a7\u72ec\u7acb\u9664\u6e7f<\/strong>\uff08\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u5bf9\u5730\u4e0b\u5ba4\u9632\u6f6e\u6bd4\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\u66f4\u7cbe\u51c6\uff09\uff0c\u5730\u4e0b\u5ba4\u4ec5\u9700<strong>\u65e5\u7acb\u4e91\u51c0\u666e\u901a\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/strong>\uff08\u9762\u4ef76,200+\u5b89\u88c56,000\uff09\u8d1f\u8d23\u901a\u98ce\u6362\u6c14\u5373\u53ef\u3002<br><br>\n    <strong>\u7814\u5224\uff1a<\/strong>\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\u4e0e\u5730\u4e0b\u5ba4\u9632\u6f6e\uff0c\u5c0a\u777f\u5185\u7f6e\u9664\u6e7f\u8def\u5f84B\u66f4\u7cbe\u51c6\u3001\u66f4\u5065\u5eb7\uff0c\u4e14\u7701\u53bb\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\u7684\u989d\u5916\u6295\u5165\u4e0e\u529f\u8017\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5206\u623f\u95f4\u51b7\u8d1f\u8377\u8ba1\u7b97\uff08GB 50736-2012\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u51b7\u6307\u6807\u6309\u522b\u5885\u7c7b80~120W\/\u33a1\u53d6\u503c\uff1b\u914d\u7f6e\u5185\u673a\u5236\u51b7\u91cf\u4e3a\u65b9\u6848\u4e8c\/\u4e09\uff08\u5c0a\u777f\u5168\u6548\uff09\u5b9e\u9645\u9009\u578b\uff0c\u90e8\u5206\u5c0f\u9762\u79ef\/\u4f4e\u9891\u623f\u95f4\u6309\u673a\u578b\u4e0b\u9650\u9009\u914d\u3002\u5408\u8ba1\u51b7\u8d1f\u8377\u224847.4kW\uff0c\u4e0e\u4e3b\u673a\u80fd\u529b\uff08\u65b9\u6848\u4e0044.8kW \/ \u65b9\u6848\u4e8c224+280\u5206\u533a\uff09\u5339\u914d\u3002<\/p>\n  <table class=\"lm-table\">\n    <tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u51b7\u6307\u6807(W\/\u33a1)<\/th><th>\u8ba1\u7b97\u51b7\u8d1f\u8377(kW)<\/th><th>\u914d\u7f6e\u5185\u673a\u5236\u51b7\u91cf(kW)<\/th><\/tr>\n    <tr><td>\u8d1f2F<\/td><td>\u5065\u8eab\u533a<\/td><td>31<\/td><td>100<\/td><td>3.1<\/td><td>2.8<\/td><\/tr>\n    <tr><td>\u8d1f2F<\/td><td>\u978b\u5e3d\u533a<\/td><td>56<\/td><td>100<\/td><td>5.6<\/td><td>5.0<\/td><\/tr>\n    <tr><td>\u8d1f1F<\/td><td>\u5a31\u4e50\u5ba4<\/td><td>45<\/td><td>100<\/td><td>4.5<\/td><td>4.5<\/td><\/tr>\n    <tr><td>\u8d1f1F<\/td><td>\u963f\u59e8\u623f<\/td><td>8<\/td><td>100<\/td><td>0.8<\/td><td>2.2<\/td><\/tr>\n    <tr><td>1F<\/td><td>\u5ba2\u9910\u5385<\/td><td>89<\/td><td>120<\/td><td>10.7<\/td><td>12.7<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u7236\u6bcd\u623f<\/td><td>34<\/td><td>110<\/td><td>3.7<\/td><td>5.6<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u6b21\u5367<\/td><td>39<\/td><td>110<\/td><td>4.3<\/td><td>5.6<\/td><\/tr>\n    <tr><td>3F<\/td><td>\u7537\u5b69\u623f<\/td><td>39<\/td><td>110<\/td><td>4.3<\/td><td>5.6<\/td><\/tr>\n    <tr><td>3F<\/td><td>\u5973\u5b69\u623f<\/td><td>39<\/td><td>110<\/td><td>4.3<\/td><td>5.6<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u4e3b\u5367+\u8fc7\u9053<\/td><td>22<\/td><td>110<\/td><td>2.4<\/td><td>5.6<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u8863\u5e3d\u95f4<\/td><td>14<\/td><td>100<\/td><td>1.4<\/td><td>2.2<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u79c1\u57df\u7a7a\u95f4<\/td><td>21<\/td><td>110<\/td><td>2.3<\/td><td>3.2<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"4\">\u5408\u8ba1\uff0813\u53f0\u5ba4\u5185\u673a\uff09<\/td><td>\u224847.4<\/td><td>\u2014<\/td><\/tr>\n  <\/table>\n<\/section>\n\n<!-- ===== S2\u00b7\u65b9\u6848\u8bca\u65ad ===== -->\n<section class=\"lm-section\" id=\"s2\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S2<\/span>\u65b9\u6848\u8bca\u65ad<\/div>\n\n  <p style=\"margin-bottom:16px;color:var(--lm-text2);\">\u9488\u5bf9\u6731\u8001\u5e08&#8221;\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u63a7\u5236\u9884\u7b97&#8221;\u7684\u6838\u5fc3\u8bc9\u6c42\uff0c\u4ee5\u4e0b\u4ece<strong style=\"color:var(--lm-gold2);\">\u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848\u00b7\u6c34\u5885\u9002FX\u4e8c\u8054\u4f9b\uff08\u65b9\u6848\u4e00\uff09<\/strong>\u3001<strong style=\"color:var(--lm-gold2);\">\u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848\u00b7\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u4e8c\u8054\u4f9b\uff08\u65b9\u6848\u4e8c\uff09<\/strong>\u3001<strong style=\"color:var(--lm-gold2);\">20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848\u00b7\u5c0a\u777f\u5168\u6548\u4e2d\u592e\u7a7a\u8c03\uff08\u65b9\u6848\u4e09\uff09<\/strong>\u5c55\u5f00\u5206\u7ef4\u5ea6\u8bca\u65ad\uff0c\u6309&#8221;\u4f53\u9a8c \/ \u6280\u672f \/ \u8fd0\u7ef4&#8221;\u4e09\u7c7b\u5207\u6362\u67e5\u770b\u3002<\/p>\n\n  <div class=\"lm-compare-grid\">\n    <div class=\"lm-compare-card\">\n      <span class=\"lm-badge lm-badge-comp\">\u65b9\u6848\u4e00 \u00b7 \u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848<\/span>\n      <h4>\u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848\uff08\u6c34\u5885\u9002FX \u4e8c\u8054\u4f9b\u00b7\u53cc\u673a\u5e76\u8054\uff09<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a\u5168\u5c4b\uff08\u8d1f2F-4F\uff09<\/p>\n      <ul>\n        <li>2\u00d7 RAS-252FPUENY2Q\/M \u5e76\u673a<\/li>\n        <li>13\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\uff08RFP\uff09<\/li>\n        <li>\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\uff08\u5730\u4e0b\u5ba4\uff09<\/li>\n        <li>\u53cc\u673a\u4e00\u7528\u4e00\u5907\uff0c\u5927\u5b85\u8282\u80fd\u5197\u4f59<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lm-compare-card lm-recommend\">\n      <span class=\"lm-badge lm-badge-rec\">\u65b9\u6848\u4e8c \u00b7 \u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848<\/span>\n      <h4>\u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848\uff08\u5c0a\u777f\u5168\u6548 + \u6c34\u6a21\u5757 \u4e8c\u8054\u4f9b\uff09<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a\u5168\u5c4b\uff08\u8d1f2F-4F\uff09<\/p>\n      <ul>\n        <li>224+280 \u4e24\u53f0\u5c0a\u777f\u5168\u6548\u4e3b\u673a<\/li>\n        <li>13\u53f0\u4e09\u7ba1\u5236\/\u4e8c\u7ba1\u5236\u5185\u673a<\/li>\n        <li>\u6c34\u6a21\u5757224+280\uff08\u70ed\u6cf5\u5730\u6696\uff09<\/li>\n        <li>\u6e29\u6e7f\u53cc\u63a7+\u81ea\u6e05\u6d01+\u4e91\u51c0\u65b0\u98ce<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lm-compare-card\">\n      <span class=\"lm-badge lm-badge-comp\">\u65b9\u6848\u4e09 \u00b7 20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848<\/span>\n      <h4>20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848\uff08\u5c0a\u777f\u5168\u6548 \u4e2d\u592e\u7a7a\u8c03\uff09<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a\u5168\u5c4b\uff08\u8d1f2F-4F\uff09<\/p>\n      <ul>\n        <li>\u914d\u7f6e\u540c\u65b9\u6848\u4e8c\uff08\u65e0\u6c34\u4e0a\u5757\uff09<\/li>\n        <li>13\u53f0\u4e09\u7ba1\u5236\/\u4e8c\u7ba1\u5236\u5185\u673a<\/li>\n        <li>\u5730\u6696\u5168\u7531\u9505\u7089\u627f\u62c5<\/li>\n        <li>\u521d\u671f\u6295\u5165\u6700\u4f4e<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-tabs-nav\">\n    <button class=\"lm-tab-btn lm-active\" data-tab=\"t1\">\u4f53\u9a8c\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t2\">\u6280\u672f\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t3\">\u8fd0\u7ef4\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t4\">\u9884\u7b97\u7ef4\u5ea6<\/button>\n  <\/div>\n\n  <div class=\"lm-tab-panel lm-active\" id=\"t1\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:15%;\">\u7ef4\u5ea6<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e00 \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/th><th style=\"width:29%;\">\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03<\/th><\/tr>\n      <tr><td><strong>\u51fa\u98ce\u4f53\u9a8c<\/strong><\/td><td>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u67d4\u548c\u5982\u81ea\u7136\u98ce\uff0c\u9002\u5408\u6015\u51c9\u4eba\u7fa4<\/td><td>\u6c1f\u76f4\u51b77-12\u2103\u5236\u51b7\u5feb\uff1b\u4e09\u7ba1\u5236\u4e0d\u964d\u6e29\u9664\u6e7f<\/td><td>\u540c\u65b9\u6848\u4e8c\uff08\u7a7a\u8c03\u4f53\u9a8c\u4e00\u81f4\uff09<\/td><\/tr>\n      <tr><td><strong>\u5730\u4e0b\u5ba4\u9664\u6e7f<\/strong><\/td><td>\u9700\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\uff08\u989d\u5916\u6295\u5165\uff0c\u72ec\u7acb\u9664\u6e7f\uff09<\/td><td>\u4e09\u7ba1\u5236\u5185\u7f6e\u6e29\u6e7f\u53cc\u63a7\uff0c\u7cbe\u51c6\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u4f18\u4e8e\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce<\/td><td>\u540c\u65b9\u6848\u4e8c\uff08\u5185\u7f6e\u9664\u6e7f\uff09<\/td><\/tr>\n      <tr><td><strong>\u7a7a\u6c14\u5065\u5eb7<\/strong><\/td><td>\u65e0\u5185\u7f6e\u51c0\u5316\uff0c\u9700\u65b0\u98ce\u8865\u4f4d<\/td><td>\u6807\u914dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff08\u9664\u83cc\u9664\u919b\u9664\u5c18\uff0cPM2.5\u53bb\u966499%\uff09+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><td>\u540c\u65b9\u6848\u4e8c\uff08\u51c0\u5316\u4e00\u81f4\uff09<\/td><\/tr>\n      <tr><td><strong>\u5730\u6696\u8212\u9002<\/strong><\/td><td>\u6c34\u7cfb\u7edf\u5730\u6696\u5747\u5300\u67d4\u548c<\/td><td>\u6c34\u6a21\u5757\u9a71\u52a8\u5730\u6696\uff0c\u5747\u5300\u8212\u9002<\/td><td>\u9505\u7089\u76f4\u4f9b\u5730\u6696\uff0c\u5747\u5300\u8212\u9002<\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t2\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:15%;\">\u7ef4\u5ea6<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e00 \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/th><th style=\"width:29%;\">\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03<\/th><\/tr>\n      <tr><td><strong>\u7cfb\u7edf\u7c7b\u578b<\/strong><\/td><td><span class=\"lm-tag lm-tag-orange\">\u5929\u6c34\u5730\u6c34<\/span>\u7a7a\u8c03\u4e0e\u5730\u6696\u5747\u6c34\u7cfb\u7edf\uff08\u4e8c\u6b21\u6362\u70ed\uff09<\/td><td><span class=\"lm-tag lm-tag-blue\">\u5929\u6c1f\u5730\u6c34<\/span>\u7a7a\u8c03\u6c1f\u76f4\u51b7+\u6c34\u6a21\u5757\u5730\u6696<\/td><td><span class=\"lm-tag lm-tag-blue\">\u6c1f\u7cfb\u7edf<\/span>\u7a7a\u8c03\u6c1f\u76f4\u51b7\uff0c\u5730\u6696\u53e6\u7b97<\/td><\/tr>\n      <tr><td><strong>\u4e3b\u673a\u67b6\u6784<\/strong><\/td><td>2\u00d722.4kW\u5e76\u673a\uff0c\u4e00\u7528\u4e00\u5907\uff0c\u4e0d\u53d7\u914d\u6bd4\u7387\u9650\u5236<\/td><td>224\uff08\u8d1f2-1F\uff09+280\uff082-4F\uff09\u5206\u533a\uff0c\u8fde\u63a5\u738793%\/96%<\/td><td>\u540c\u65b9\u6848\u4e8c\uff08\u4e3b\u673a\u4e00\u81f4\uff09<\/td><\/tr>\n      <tr><td><strong>\u5b89\u88c5\u590d\u6742\u5ea6<\/strong><\/td><td><span class=\"lm-tag lm-tag-red\">\u8981\u6c42\u6781\u9ad8<\/span>\u9700\u6c34\u529b\u5e73\u8861\uff0c\u4e0d\u5f53\u6613\u6f0f\u6c34\/\u7ed3\u9732<\/td><td><span class=\"lm-tag lm-tag-green\">\u6807\u51c6\u5316<\/span>\u6c1f\u94dc\u7ba1\u6807\u51c6\u5316+\u6c34\u6a21\u5757\u7b80\u5355\u63a5\u7ba1<\/td><td><span class=\"lm-tag lm-tag-green\">\u6807\u51c6\u5316<\/span>\u7eaf\u6c1f\u7cfb\u7edf\uff0c\u6700\u7b80\u5355<\/td><\/tr>\n      <tr><td><strong>\u4e8c\u8054\u4f9b\u80fd\u529b<\/strong><\/td><td>\u6c34\u673a\u672c\u8eab\u5177\u5907\u5730\u6696\u63a5\u53e3<\/td><td>\u6c34\u6a21\u5757\u4f7f\u70ed\u6cf5\u53c2\u4e0e\u5730\u6696\uff08COP\u22653\uff0c\u7701\u6c14\uff09<\/td><td>\u65e0\uff08\u5730\u6696\u5168\u9760\u9505\u7089\uff09<\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t3\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:15%;\">\u7ef4\u5ea6<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e00 \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/th><th style=\"width:29%;\">\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03<\/th><\/tr>\n      <tr><td><strong>\u81ea\u6e05\u6d01<\/strong><\/td><td>\u6c34\u7cfb\u7edf\u65e0\u81ea\u6e05\u6d01\uff0c\u9700\u5b9a\u671f\u4eba\u5de5\u6e05\u6d17<\/td><td>\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff0c\u51cf\u5c11\u4eba\u5de5\u6e05\u6d17<\/td><td>\u540c\u65b9\u6848\u4e8c<\/td><\/tr>\n      <tr><td><strong>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/strong><\/td><td>\u5168\u6c34\u7cfb\u7edf\u63a5\u5934\u591a\uff0c\u957f\u671f\u6f0f\u6c34\u98ce\u9669<\/td><td>\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u5bc6\u5c01\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669<\/td><td>\u6c1f\u7cfb\u7edf\uff0c\u6700\u7a33\u5b9a<\/td><\/tr>\n      <tr><td><strong>\u5197\u4f59\u5907\u4efd<\/strong><\/td><td><span class=\"lm-tag lm-tag-green\">\u4e00\u7528\u4e00\u5907<\/span>\u4e00\u53f0\u574f\u4e0d\u5f71\u54cd\u4f7f\u7528<\/td><td>\u4e24\u53f0\u4e3b\u673a\u5206\u533a\uff0c\u5355\u53f0\u6545\u969c\u5f71\u54cd\u534a\u5b85<\/td><td>\u540c\u65b9\u6848\u4e8c<\/td><\/tr>\n      <tr><td><strong>\u7ef4\u62a4\u9700\u6c42<\/strong><\/td><td><span class=\"lm-tag lm-tag-orange\">\u9ad8<\/span>\u5b9a\u671f\u6d17\u8fc7\u6ee4\u5668\/\u6392\u6c14\/\u8865\u6c34<\/td><td><span class=\"lm-tag lm-tag-green\">\u4f4e<\/span>\u81ea\u6e05\u6d01+\u5e74\u5ea6\u56de\u8bbf<\/td><td><span class=\"lm-tag lm-tag-green\">\u4f4e<\/span>\u6700\u4f4e<\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t4\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:15%;\">\u7ef4\u5ea6<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e00 \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:28%;\">\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/th><th style=\"width:29%;\">\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03<\/th><\/tr>\n      <tr><td><strong>\u8bbe\u5907\u603b\u6295\u5165<\/strong><\/td><td>\u7ea6 274,748 \u5143\uff08\u5c45\u4e2d\uff09<\/td><td>\u7ea6 270,713 \u5143\uff08\u6700\u4f4e\uff09<\/td><td>\u7ea6 280,006 \u5143\uff08\u6700\u9ad8\uff09<\/td><\/tr>\n      <tr><td><strong>\u521d\u671f\u9884\u7b97<\/strong><\/td><td>\u53cc\u5927\u4e3b\u673a+\u9664\u6e7f\u65b0\u98ce\uff0c\u6295\u5165\u5c45\u4e2d<\/td><td><span class=\"lm-tag lm-tag-green\">\u6700\u4f4e<\/span>\u6bd4\u6c34\u5885\u9002\u77014,035\u3001\u6bd4\u4e2d\u592e\u7a7a\u8c03\u77019,293<\/td><td>\u65e0\u6c34\u6a21\u5757\u4f46\u9700\u8865\u71c3\u6c14\u9505\u7089\uff0c\u521d\u671f\u53cd\u800c\u6700\u9ad8<\/td><\/tr>\n      <tr><td><strong>\u957f\u671f\u8fd0\u884c\u8d39<\/strong><\/td><td>\u6c34\u673a\u9ad8\u6548\uff0c\u4f46\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u8017\u7535\u504f\u9ad8<\/td><td><span class=\"lm-tag lm-tag-green\">\u6700\u4f18<\/span>\u70ed\u6cf5\u5730\u6696\u7701\u6c14<\/td><td>\u5730\u6696\u5168\u71c3\u6c14\uff0c\u8fd0\u884c\u8d39\u6700\u9ad8<\/td><\/tr>\n      <tr><td><strong>\u9884\u7b97\u53cb\u597d\u5ea6<\/strong><\/td><td>\u9002\u5408\u91cd\u5197\u4f59\u9884\u7b97\u5bbd\u677e<\/td><td>\u521d\u6295\u6700\u4f4e + \u8fd0\u884c\u6700\u4f4e\uff0c\u7efc\u5408\u6027\u4ef7\u6bd4\u6700\u9ad8<\/td><td>\u521d\u671f\u6700\u9ad8\u4e14\u8fd0\u884c\u6700\u9ad8\uff0c\u6027\u4ef7\u6bd4\u6700\u4f4e<\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-highlight\" style=\"margin:20px 0;\">\n    <strong>\u7efc\u5408\u7ed3\u8bba\uff1a<\/strong>\u9488\u5bf9\u6731\u8001\u5e08&#8221;\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u63a7\u5236\u9884\u7b97&#8221;\u7684\u6838\u5fc3\u8bc9\u6c42\uff0c<strong>\u63a8\u8350\u65b9\u6848\u4e8c\uff08\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff09<\/strong>\uff1a<br>\n    1. <strong>\u5065\u5eb7\u8212\u9002<\/strong>\u2014\u2014\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u72ec\u7acb\u4e0d\u964d\u6e29\u9664\u6e7f\uff08\u5730\u4e0b\u5ba4\u9632\u6f6e\u4f18\u4e8e\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff09+ PE\u51c0\u5316\u6807\u914d + \u81ea\u6e05\u6d01 + \u9ad8\u6e29\u6740\u83cc\uff1b<br>\n    2. <strong>\u8282\u80fd<\/strong>\u2014\u2014\u6c34\u6a21\u5757\u4f7f\u70ed\u6cf5\u53c2\u4e0e\u5730\u6696\uff08COP\u22653\uff09\uff0c\u957f\u671f\u7701\u6c14\uff0c\u8fd0\u884c\u8d39\u4e09\u65b9\u6848\u6700\u4f18\uff1b<br>\n    3. <strong>\u7a33\u5b9a<\/strong>\u2014\u2014\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669\uff0c\u7ef4\u62a4\u7b80\u5355\uff1b<br>\n    4. <strong>\u9884\u7b97\u53ef\u63a7<\/strong>\u2014\u2014\u521d\u6295\u8d44 270,713 \u5143\u4e3a\u4e09\u65b9\u6848<strong>\u6700\u4f4e<\/strong>\uff08\u6bd4\u6c34\u5885\u9002\u7701 4,035 \u5143\u3001\u6bd4\u4e2d\u592e\u7a7a\u8c03\u7701 9,293 \u5143\uff09\uff0c\u4e14 20 \u5e74\u8fd0\u884c\u8d39\u4e5f\u6700\u4f4e\uff08\u89c1\u4e0b\u65b9\u53cd\u8f6c\u5361\u7247\uff09\uff0c\u521d\u671f\u4e0e\u5168\u5468\u671f&#8221;\u53cc\u4f4e&#8221;\uff0c\u6027\u4ef7\u6bd4\u6700\u9ad8\u3002\n  <\/div>\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u65b9\u6848\u52a3\u52bf\u8bda\u5b9e\u62ab\u9732<\/h3>\n  <div class=\"lm-highlight-blue\" style=\"font-size:13px;line-height:1.8;\">\n    <strong>\u6ca1\u6709&#8221;\u5b8c\u7f8e\u65b9\u6848&#8221;\uff0c\u53ea\u6709&#8221;\u6700\u9002\u5408&#8221;\uff0c\u4ee5\u4e0b\u4e3a\u4e09\u5957\u65b9\u6848\u7684\u771f\u5b9e\u6743\u8861\uff1a<\/strong><br>\n    1. <strong>\u6c34\u5885\u9002\uff08\u65b9\u6848\u4e00\uff09\uff1a<\/strong>\u51fa\u98ce\u67d4\u548c\u3001\u53cc\u673a\u4e00\u7528\u4e00\u5907\u5197\u4f59\u5f3a\uff0c\u4f46<strong>\u5168\u6c34\u7cfb\u7edf\u7ef4\u62a4\u9700\u6c42\u9ad8<\/strong>\uff08\u9700\u5b9a\u671f\u6e05\u6d17\u8fc7\u6ee4\u5668\/\u6392\u6c14\/\u8865\u6c34\uff09\uff0c\u4e14\u9700\u989d\u5916\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\uff0c\u521d\u6295\u5e76\u975e\u6700\u4f4e\u3002<br>\n    2. <strong>\u5c0a\u777f+\u6c34\u6a21\u5757\uff08\u65b9\u6848\u4e8c\uff09\uff1a<\/strong><strong>\u521d\u6295\u7565\u9ad8\u4e8e\u5355\u4e00\u4e2d\u592e\u7a7a\u8c03<\/strong>\uff08\u56e0\u542b\u70ed\u6cf5\u5730\u6696\u6c34\u6a21\u5757\uff09\uff0c\u4f46\u957f\u671f\u7701\u6c14\uff08\u70ed\u6cf5COP\u22653\uff09\u3001\u7ef4\u62a4\u7b80\u5355\uff0c\u5168\u5468\u671f&#8221;\u53cc\u4f4e&#8221;\u7efc\u5408\u6027\u4ef7\u6bd4\u6700\u9ad8\u2014\u2014\u8fd9\u4e5f\u662f\u63a8\u8350\u5b83\u7684\u6838\u5fc3\u539f\u56e0\u3002<br>\n    3. <strong>\u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03\uff08\u65b9\u6848\u4e09\uff09\uff1a<\/strong>\u7cfb\u7edf\u6700\u7b80\u5355\u3001\u521d\u6295\u770b\u4f3c\u4f4e\uff0c\u4f46<strong>\u5730\u6696\u5168\u7531\u71c3\u6c14\u9505\u7089\u627f\u62c5\uff0c20\u5e74\u8fd0\u884c\u8d39\u6700\u9ad8<\/strong>\uff0c\u4e14\u65e0\u70ed\u6cf5\u5730\u6696\u8282\u80fd\u7ea2\u5229\u3002<br>\n    4. <strong>\u5171\u540c\u524d\u63d0\uff1a<\/strong>\u5730\u4e0b\u5ba4\u9632\u6f6e\u5c0a\u777f\u5185\u7f6e\u6e29\u6e7f\u53cc\u63a7\u66f4\u7cbe\u51c6\uff1b\u82e5\u683c\u5916\u770b\u91cd&#8221;\u6015\u51c9\u98ce+\u6781\u81f4\u5197\u4f59&#8221;\uff0c\u6c34\u5885\u9002\u4ecd\u662f\u53ef\u9009\u8def\u5f84\u3002\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u9002\u7528\u60c5\u666f\u5bf9\u6bd4\u901f\u67e5<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u5ba2\u6237\u573a\u666f<\/th><th>\u63a8\u8350\u65b9\u6848<\/th><th>\u7406\u7531<\/th><\/tr>\n    <tr><td>\u5bf9\u5730\u4e0b\u5ba4\u9664\u6e7f\u6709\u521a\u9700\uff08\u6885\u96e8\u5b63\/\u522b\u5885\uff09<\/td><td><span class=\"lm-tag lm-tag-blue\">\u65b9\u6848\u4e8c\/\u4e09 \u5c0a\u777f<\/span><\/td><td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u5185\u7f6e\u7cbe\u51c6\u4e0d\u964d\u6e29\u9664\u6e7f<\/td><\/tr>\n    <tr><td>\u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\uff0c\u6015\u51b7\u98ce\u76f4\u5439<\/td><td><span class=\"lm-tag lm-tag-orange\">\u65b9\u6848\u4e00 \u6c34\u5885\u9002<\/span><\/td><td>\u51fa\u98ce15-20\u2103\u66f4\u67d4\u548c<\/td><\/tr>\n    <tr><td>\u9700\u8981\u81ea\u6e05\u6d01+\u7a7a\u6c14\u51c0\u5316<\/td><td><span class=\"lm-tag lm-tag-blue\">\u65b9\u6848\u4e8c\/\u4e09 \u5c0a\u777f<\/span><\/td><td>\u6807\u914dPE\u51c0\u5316+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><\/tr>\n    <tr><td>\u5927\u5b85\u91cd\u5197\u4f59\u3001\u6015\u5355\u673a\u6545\u969c<\/td><td><span class=\"lm-tag lm-tag-orange\">\u65b9\u6848\u4e00 \u6c34\u5885\u9002<\/span><\/td><td>\u53cc\u673a\u5e76\u8054\u4e00\u7528\u4e00\u5907<\/td><\/tr>\n    <tr><td>\u9884\u7b97\u4f18\u5148\u3001\u5e0c\u671b\u521d\u671f\u6295\u5165\u6700\u4f4e<\/td><td><span class=\"lm-tag lm-tag-green\">\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/span><\/td><td>\u521d\u6295270,713\u5143\u6700\u4f4e\uff08\u542b\u70ed\u6cf5\u5730\u6696\uff0c\u65e0\u9700\u71c3\u6c14\u9505\u7089\uff09\uff1b\u65b9\u6848\u4e09\u867d\u65e0\u6c34\u6a21\u5757\u4f46\u9700\u8865\u83f2\u65af\u66fc\u9505\u7089\uff0c\u53cd\u6210\u6700\u9ad8<\/td><\/tr>\n    <tr><td>\u8ffd\u6c42\u957f\u671f\u8fd0\u884c\u8282\u80fd\uff08\u70ed\u6cf5\u5730\u6696\uff09<\/td><td><span class=\"lm-tag lm-tag-blue\">\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/span><\/td><td>\u70ed\u6cf5\u5730\u6696COP\u22653\uff0c\u7701\u71c3\u6c14\uff0c20\u5e74\u8fd0\u884c\u8d39\u6700\u4f4e<\/td><\/tr>\n  <\/table>\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u516d\u7ef4\u5ea6\u8bc4\u5206\u5361\uff08\u60ac\u505c\u7ffb\u8f6c\u770b\u8bc4\u5206\u4f9d\u636e\uff09<\/h3>\n  <div class=\"lm-score-grid\">\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u521d\u6295\u8d44<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:92%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:88%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u521d\u6295\u8d44\u8bc4\u5206<\/div>\n        <ul><li>\u65b9\u6848\u4e8c 270,713\u5143 \u6700\u4f4e\uff08\u542b\u70ed\u6cf5\u5730\u6696\uff09<\/li><li>\u65b9\u6848\u4e00 274,748\u5143 \u5c45\u4e2d<\/li><li>\u65b9\u6848\u4e09 280,006\u5143 \u6700\u9ad8\uff08\u9700\u8865\u9505\u7089\uff09<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u8fd0\u884c\u8d39<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:85%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:70%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u8fd0\u884c\u8d39\u8bc4\u5206<\/div>\n        <ul><li>\u65b9\u6848\u4e8c \u70ed\u6cf5\u5730\u6696COP\u22653 \u6700\u7701\u6c14<\/li><li>\u65b9\u6848\u4e00 \u6c34\u673a\u9ad8\u6548\u4f46\u9664\u6e7f\u65b0\u98ce\u8017\u7535\u504f\u9ad8<\/li><li>\u65b9\u6848\u4e09 \u5730\u6696\u5168\u71c3\u6c14 20\u5e74\u6700\u9ad8<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u8212\u9002\u5ea6<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:90%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:95%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:95%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u8212\u9002\u5ea6\u8bc4\u5206<\/div>\n        <ul><li>\u5c0a\u777f PE\u51c0\u5316+\u81ea\u6e05\u6d01+\u6e29\u6e7f\u53cc\u63a7 \u66f4\u4f18<\/li><li>\u6c34\u5885\u9002\u51fa\u98ce15-20\u2103\u66f4\u67d4\u548c<\/li><li>\u5730\u4e0b\u5ba4\u9632\u6f6e\u5c0a\u777f\u5185\u7f6e\u9664\u6e7f\u66f4\u7cbe\u51c6<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u7a33\u5b9a\u6027<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:80%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u7a33\u5b9a\u6027\u8bc4\u5206<\/div>\n        <ul><li>\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u5bc6\u5c01 \u65e0\u6f0f\u6c34\u98ce\u9669<\/li><li>\u6c34\u7cfb\u7edf\u63a5\u5934\u591a \u957f\u671f\u6f0f\u6c34\u98ce\u9669<\/li><li>\u65b9\u6848\u4e8c\/\u4e09 \u5206\u533a\u5355\u53f0\u6545\u969c\u5f71\u54cd\u534a\u5b85<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u7ef4\u62a4\u8d39<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:70%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u7ef4\u62a4\u8d39\u8bc4\u5206<\/div>\n        <ul><li>\u6c1f\u7cfb\u7edf \u81ea\u6e05\u6d01+\u5e74\u5ea6\u56de\u8bbf \u7ef4\u62a4\u4f4e<\/li><li>\u6c34\u7cfb\u7edf \u9700\u5b9a\u671f\u6e05\u6d17\/\u6392\u6c14\/\u8865\u6c34<\/li><li>\u7ef4\u62a4\u9700\u6c42\uff1a\u65b9\u6848\u4e8c\/\u4e09 \u4f4e \u00b7 \u65b9\u6848\u4e00 \u9ad8<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u5bff\u547d<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:85%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:88%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u5bff\u547d\u8bc4\u5206<\/div>\n        <ul><li>\u5c0a\u777f\u5168\u6548 20\u5e74\u514d\u66f4\u6362<\/li><li>\u71c3\u6c14\u9505\u7089 7-8\u5e74\u5f3a\u5236\u66f4\u6362<\/li><li>\u65b9\u6848\u4e8c \u6c1f\u673a+\u70ed\u6cf5 \u5168\u5468\u671f\u6700\u7701<\/li><\/ul><\/div>\n    <\/div><\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== S3\u00b7\u7cfb\u7edf\u8bbe\u8ba1 ===== -->\n<section class=\"lm-section\" id=\"s3\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S3<\/span>\u7cfb\u7edf\u8bbe\u8ba1<\/div>\n\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u67b6\u6784\u603b\u89c8<\/h3>\n  <div class=\"lm-compare-grid\">\n    <div class=\"lm-compare-card\">\n      <span class=\"lm-badge lm-badge-comp\">\u65b9\u6848\u4e00 \u00b7 \u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848<\/span>\n      <h4>\u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848\uff08\u6c34\u5885\u9002FX \u4e8c\u8054\u4f9b\uff09<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u5168\u5c4b\u51b7\u70ed\u6e90<\/p>\n      <ul>\n        <li>2\u00d7 RAS-252FPUENY2Q\/M \u5e76\u673a\uff0844.8kW\uff09<\/li>\n        <li>13\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1<\/li>\n        <li>\u5730\u4e0b\u5ba4\uff1a\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350<\/li>\n        <li>\u5404\u5c42\uff1a\u5355\u5411\u6d41\u65b0\u98ce\u00d74<\/li>\n        <li>\u5730\u6696\uff1a\u6c34\u673a\u70ed\u6cf5\u5730\u6696\uff08\u9f99\u8109179\u7cfb\u7edf\uff09\u00b7 \u65e0\u72ec\u7acb\u9505\u7089<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lm-compare-card lm-recommend\">\n      <span class=\"lm-badge lm-badge-rec\">\u65b9\u6848\u4e8c \u00b7 \u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848<\/span>\n      <h4>\u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848\uff08\u5c0a\u777f\u5168\u6548 + \u6c34\u6a21\u5757 \u4e8c\u8054\u4f9b\uff09<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u5168\u5c4b\u51b7\u70ed\u6e90<\/p>\n      <ul>\n        <li>224\uff08\u8d1f2-1F\uff09+280\uff082-4F\uff09<\/li>\n        <li>13\u53f0\u4e09\u7ba1\u5236\/\u4e8c\u7ba1\u5236\u5185\u673a<\/li>\n        <li>\u6c34\u6a21\u5757224+280\uff08\u70ed\u6cf5\u5730\u6696\uff09<\/li>\n        <li>\u5730\u4e0b\u5ba4\uff1a\u4e91\u51c0\u5168\u70ed\u4ea4\u6362<\/li>\n        <li>\u5404\u5c42\uff1a\u5355\u5411\u6d41\u65b0\u98ce\u00d74<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lm-compare-card\">\n      <span class=\"lm-badge lm-badge-comp\">\u65b9\u6848\u4e09 \u00b7 20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848<\/span>\n      <h4>20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848\uff08\u5c0a\u777f\u5168\u6548 \u4e2d\u592e\u7a7a\u8c03\uff09<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u5168\u5c4b\u51b7\u70ed\u6e90<\/p>\n      <ul>\n        <li>\u4e3b\u673a\u914d\u7f6e\u540c\u65b9\u6848\u4e8c<\/li>\n        <li>13\u53f0\u4e09\u7ba1\u5236\/\u4e8c\u7ba1\u5236\u5185\u673a<\/li>\n        <li>\u65e0\u6c34\u6a21\u5757\uff08\u5730\u6696\u5168\u9505\u7089\uff09<\/li>\n        <li>\u5730\u4e0b\u5ba4\uff1a\u4e91\u51c0\u5168\u70ed\u4ea4\u6362<\/li>\n        <li>\u5404\u5c42\uff1a\u5355\u5411\u6d41\u65b0\u98ce\u00d74<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u65b9\u6848\u4e00 \u00b7 \u6c34\u5885\u9002FX \u5ba4\u5185\u673a\uff08\u98ce\u673a\u76d8\u7ba1\uff09\u914d\u7f6e<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u4ef7\u683c\u6765\u6e90\uff1a\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93V5.0 \uff5c \u6c34\u5885\u9002\u7cfb\u5217\uff08\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298\uff09<\/p>\n  <table class=\"lm-table\">\n    <tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7\uff08\u96f6\u8d8a\u578b\uff09<\/th><th>\u5236\u51b7\u91cf<\/th><th>\u6570\u91cf<\/th><\/tr>\n    <tr><td>\u8d1f\u4e8c\u697c<\/td><td>\u5065\u8eab\u533a<\/td><td>31\u33a1<\/td><td>RFP-68WAR<\/td><td>4.3kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u8d1f\u4e8c\u697c<\/td><td>\u978b\u5e3d\u533a<\/td><td>56\u33a1<\/td><td>RFP-102WAR<\/td><td>6.4kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5a31\u4e50\u5ba4<\/td><td>45\u33a1<\/td><td>RFP-119WAR<\/td><td>6.8kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u8d1f\u4e00\u697c<\/td><td>\u963f\u59e8\u623f<\/td><td>8\u33a1<\/td><td>RFP-34WAR<\/td><td>2.5kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>89\u33a1<\/td><td>RFP-153WAR<\/td><td>9.1kW<\/td><td>2<\/td><\/tr>\n    <tr><td>\u4e8c\u697c<\/td><td>\u7236\u6bcd\u623f<\/td><td>34\u33a1<\/td><td>RFP-119WAR<\/td><td>6.8kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>39\u33a1<\/td><td>RFP-136WAR<\/td><td>8.1kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u4e09\u697c<\/td><td>\u7537\u5b69\u623f<\/td><td>39\u33a1<\/td><td>RFP-136WAR<\/td><td>8.1kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u4e09\u697c<\/td><td>\u5973\u513f\u623f<\/td><td>39\u33a1<\/td><td>RFP-136WAR<\/td><td>8.1kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u56db\u697c<\/td><td>\u4e3b\u5367<\/td><td>22\u33a1<\/td><td>RFP-85WAR<\/td><td>5.7kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u56db\u697c<\/td><td>\u8863\u5e3d\u95f4<\/td><td>14\u33a1<\/td><td>RFP-34WAR<\/td><td>2.5kW<\/td><td>1<\/td><\/tr>\n    <tr><td>\u56db\u697c<\/td><td>\u79c1\u57df\u7a7a\u95f4<\/td><td>21\u33a1<\/td><td>RFP-68WAR<\/td><td>4.3kW<\/td><td>1<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"5\">\u5ba4\u5185\u673a\u5408\u8ba1\uff0813\u53f0\uff09<\/td><td>13\u53f0<\/td><\/tr>\n  <\/table>\n  <div class=\"lm-highlight-blue\" style=\"margin:16px 0;\">\n    <strong>\u5916\u673a\u4e0e\u5e76\u673a\uff1a<\/strong>2\u00d7 RAS-252FPUENY2Q\/M\uff08\u5355\u53f022.4kW\uff0c\u603b44.8kW\uff09\uff0c\u53cc\u673a\u5e76\u8054\u8fd0\u884c\uff0c\u6c34\u673a\u7cfb\u7edf\u4e0d\u53d7\u914d\u6bd4\u7387\u9650\u5236\uff0c\u4eba\u5c11\u65f6\u5355\u53f0\u4f4e\u8d1f\u8377\u3001\u4eba\u591a\u65f6\u53cc\u673a\u540c\u5f00\uff0c\u4e14\u4e00\u7528\u4e00\u5907\u3002\u5730\u4e0b\u5ba4\u9664\u6e7f\u53e6\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u65b9\u6848\u4e8c \/ \u65b9\u6848\u4e09 \u00b7 \u5c0a\u777f\u5168\u6548 \u5ba4\u5185\u673a\u914d\u7f6e<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u4ef7\u683c\u6765\u6e90\uff1a\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93V5.0 \uff5c \u5c0a\u777f\u5168\u6548\uff08\u9762\u4ef7\u00b78.5\u6298\uff09\uff5c \u8d1f1F-1F\u7528224\u4e3b\u673a\uff0c2F-4F\u7528280\u4e3b\u673a<\/p>\n  <table class=\"lm-table\">\n    <tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u5236\u51b7\u91cf<\/th><th>\u5185\u673a\u7c7b\u578b<\/th><th>\u6240\u5c5e\u4e3b\u673a<\/th><\/tr>\n    <tr><td>\u8d1f\u4e8c\u697c<\/td><td>\u5065\u8eab\u623f<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>2.8kW<\/td><td>\u4e09\u7ba1\u5236<\/td><td rowspan=\"6\">\u5c0a\u777f224<br>\uff08\u8d1f2-1F\uff09<\/td><\/tr>\n    <tr><td>\u8d1f\u4e8c\u697c<\/td><td>\u978b\u5e3d\u533a<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5.0kW<\/td><td>\u4e09\u7ba1\u5236<\/td><\/tr>\n    <tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5a31\u4e50\u5ba4<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>4.5kW<\/td><td>\u4e09\u7ba1\u5236<\/td><\/tr>\n    <tr><td>\u8d1f\u4e00\u697c<\/td><td>\u963f\u59e8\u623f<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2kW<\/td><td>\u4e09\u7ba1\u5236<\/td><\/tr>\n    <tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-71FSVNZ1QD\/PC<\/td><td>7.1kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5.6kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u4e8c\u697c<\/td><td>\u7236\u6bcd\u623f<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5.6kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><td rowspan=\"7\">\u5c0a\u777f280<br>\uff082-4F\uff09<\/td><\/tr>\n    <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5.6kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u4e09\u697c<\/td><td>\u7537\u5b69\u623f<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5.6kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u4e09\u697c<\/td><td>\u5973\u5b69\u623f<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5.6kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u56db\u697c<\/td><td>\u4e3b\u5367+\u8fc7\u9053<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5.6kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u56db\u697c<\/td><td>\u8863\u5e3d\u95f4<\/td><td>RPIZ-22FSVNZ1QD\/PC<\/td><td>2.2kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr><td>\u56db\u697c<\/td><td>\u79c1\u57df\u7a7a\u95f4<\/td><td>RPIZ-32FSVNZ1QD\/PC<\/td><td>3.2kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"5\">\u5ba4\u5185\u673a\u5408\u8ba1\uff0813\u53f0\uff0c\u65b9\u6848\u4e8c\/\u4e09\u4e00\u81f4\uff09<\/td><td>13\u53f0<\/td><\/tr>\n  <\/table>\n  <div class=\"lm-highlight-green\" style=\"margin:16px 0;\">\n    <strong>\u8bbe\u8ba1\u539f\u5219\uff1a<\/strong>\u6309GEO\u4e94\u6b65\u6cd5\u89c4\u8303\u8bbe\u8ba1\uff0c\u4e25\u683c\u9075\u5faaGB 50736-2012\u5236\u51b7\u8d1f\u8377\u6807\u51c6\uff08\u522b\u5885\u7c7b80-120W\/\u33a1\uff09\u3002224\u4e3b\u673a\u8d1f\u62c5\u8d1f2F-1F\u517127.2kW\uff08\u8fde\u63a5\u738793%\uff09\uff0c280\u4e3b\u673a\u8d1f\u62c52F-4F\u517133.4kW\uff08\u8fde\u63a5\u738796%\uff09\uff0c\u5747\u5728\u5408\u7406\u8303\u56f4\uff0890-130%\uff09\uff0c\u65e2\u4fdd\u8bc1\u5168\u5f00\u6548\u679c\u4e0d\u6253\u6298\uff0c\u4e5f\u907f\u514d\u5355\u5f00\u623f\u95f4\u9891\u7e41\u542f\u505c\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u6838\u5fc3\u4ea7\u54c1\u8be6\u60c5<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin:0 0 4px;\">\u672c\u65b9\u6848\u6d89\u53ca\u56db\u5927\u6838\u5fc3\u4ea7\u54c1\uff1a\u524d\u4e24\u9879\u4e3a\u65b9\u6848\u4e8c\/\u4e09\uff08\u5c0a\u777f\u5168\u6548\uff09\u7cfb\u7edf\u914d\u7f6e\uff0c\u540e\u4e24\u9879\u4e3a\u65b9\u6848\u4e00\uff08\u6c34\u5885\u9002FX\uff09\u7cfb\u7edf\u914d\u7f6e\u3002\u8d44\u6599\u63d0\u53d6\u81ea\u300c\u9f99\u8109\u4f01\u4e1a\u77e5\u8bc6\u5e93\u300d\uff08ima\uff09\u4e0e\u65e5\u7acb\u5b98\u65b9\u4ea7\u54c1\u624b\u518c\u3002<\/p>\n  <div class=\"lm-prod-showcase\">\n    <div class=\"lm-prod-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" alt=\"VAM\u5c0a\u777f\u5168\u6548II\">\n      <div class=\"lm-pc-body\">\n        <div class=\"lm-pc-title\">\u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548\u2161<\/div>\n        <div class=\"lm-pc-desc\">\u884c\u4e1a\u9996\u6b3e\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 \u00b7 175L\/\u5929\u9664\u6e7f\u91cf \u00b7 \u5168\u98ce\u8def\u51c0\u5316\u8231 \u00b7 17dB\u6781\u81f4\u9759\u97f3<\/div>\n        <a class=\"lm-pc-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\u67e5\u770b\u5c0a\u777f\u5168\u6548\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n    <div class=\"lm-prod-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E6%97%A5%E7%AB%8B%E4%BA%91%E5%87%80%E6%96%B0%E9%A3%8E04-17.jpg\" alt=\"\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce\">\n      <div class=\"lm-pc-body\">\n        <div class=\"lm-pc-title\">\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce\u7cfb\u7edf<\/div>\n        <div class=\"lm-pc-desc\">\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362 \u00b7 PM2.5\u51c0\u5316\u7387\u226598% \u00b7 \u7eb3\u7c73\u9ad8\u5206\u5b50\u53ef\u6c34\u6d17\u82af\u4f53 \u00b7 \u6700\u4f4e19dB\u6781\u81f4\u9759\u97f3<\/div>\n        <a class=\"lm-pc-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u67e5\u770b\u65b0\u98ce\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n    <div class=\"lm-prod-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/27d76b4b48c4b6178d44db1caeee4451.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002FX \u5ba4\u5916\u673a\u4ea7\u54c1\u5b9e\u62cd\uff08\u6765\u6e90\uff1a\u9f99\u8109\u5b98\u7f51\u9996\u9875\u00b7\u4ea7\u54c1\u603b\u89c8\uff09\" \/>\n      <div class=\"lm-pc-body\">\n        <div class=\"lm-pc-title\">\u65e5\u7acb\u6c34\u5885\u9002FX \u4e3b\u673a\uff08\u65b9\u6848\u4e00\uff09<\/div>\n        <div class=\"lm-pc-desc\">\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 \u8865\u6c14\u589e\u7113\u53d8\u9891\u6da1\u65cb\u538b\u7f29\u673a \u00b7 \u5236\u51b722.4kW\/\u5236\u70ed25.2kW\u3001COP3.50 \u00b7 \u51fa\u6c345~25\u2103(\u51b7)\/25~55\u2103(\u70ed) \u00b7 -30~28\u2103\u5bbd\u6e29\u8fd0\u884c \u00b7 \u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u65e0\u7f13\u51b2\u6c34\u7bb1 \u00b7 \u51fa\u98ce15~20\u2103\u51c9\u800c\u4e0d\u5bd2<\/div>\n        <a class=\"lm-pc-link\" href=\"https:\/\/longmai-nt.com\/guide\/shuiluoshi.html\" target=\"_blank\">\u67e5\u770b\u6c34\u5885\u9002\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n    <div class=\"lm-prod-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/d91491e767b9943f450339fd7a5acc0e.jpg\" alt=\"\u65e5\u7acb\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u4ea7\u54c1\u5b9e\u62cd\uff08\u6765\u6e90\uff1a\u9f99\u8109\u5b98\u7f51\u9996\u9875\u00b7\u4ea7\u54c1\u603b\u89c8\uff09\" \/>\n      <div class=\"lm-pc-body\">\n        <div class=\"lm-pc-title\">\u65e5\u7acb\u5929\u51c0Q7 \u9664\u6e7f\u65b0\u98ce\uff08\u65b9\u6848\u4e00\u00b7\u5730\u4e0b\u5ba4\uff09<\/div>\n        <div class=\"lm-pc-desc\">\u9664\u6e7f+\u65b0\u98ce\u4e00\u4f53 \u00b7 \u72ec\u7acb\u70ed\u6cf5\u9664\u6e7f43.2L\/\u5929 \u00b7 \u5168\u70ed\u4ea4\u6362\u7eb3\u7c73\u9ad8\u5206\u5b50\u82af\u4f53\uff08\u7113\u4ea4\u6362\u226480%\uff09 \u00b7 PM2.5\u51c0\u5316\u226598% \u00b7 \u4e94\u7ef4\u76d1\u6d4b(CO\u2082\/PM2.5\/TVOC\/\u6e29\u6e7f\u5ea6) \u00b7 \u6848\u4f8b\u5b9e\u6d4b60\u5206\u949f\u6e7f\u5ea695%\u219254%<\/div>\n        <a class=\"lm-pc-link\" href=\"https:\/\/longmai-nt.com?p=1758\" target=\"_blank\">\u67e5\u770b\u5929\u51c0\u65b0\u98ce\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cbe\u5de5\u516d\u6b65\u6cd5 + 2 \u6807\u51c6\u5316\u65bd\u5de5<\/h3>\n  <div class=\"lm-step-flow\">\n    <span class=\"lm-step\">01 \u73b0\u573a\u52d8\u6d4b<\/span>\n    <span class=\"lm-step\">02 \u7cfb\u7edf\u8bbe\u8ba1<\/span>\n    <span class=\"lm-step\">03 \u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/span>\n    <span class=\"lm-step\">04 \u7cfb\u7edf\u5b89\u88c5<\/span>\n    <span class=\"lm-step\">05 \u7cfb\u7edf\u8c03\u8bd5<\/span>\n    <span class=\"lm-step\">06 \u7ae3\u5de5\u9a8c\u6536<\/span>\n    <span class=\"lm-step\">+1 \u4ea4\u4ed8\u6559\u5b66<\/span>\n    <span class=\"lm-step\">+2 \u552e\u540e\u4fdd\u969c<\/span>\n  <\/div>\n\n  <div class=\"lm-carousel\" id=\"lmCraftCarousel\">\n    <div class=\"lm-carousel-track\">\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">01<\/span><div class=\"lm-cs-title\">\u73b0\u573a\u52d8\u6d4b<\/div><\/div>\n        <div class=\"lm-cs-body\">\u8bbe\u8ba1\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u6237\u578b\u7ed3\u6784\u3001\u5c42\u9ad8\u3001\u5916\u673a\u4f4d\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\uff0c\u7cbe\u786e\u6d4b\u91cf\u5404\u623f\u95f4\u9762\u79ef\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u52d8\u6d4b\u62a5\u544a + \u73b0\u573a\u7167\u7247\u5b58\u6863<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/hlxglyt-fls-xckc-03.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u73b0\u573a\u52d8\u6d4b\u5b9e\u666f\"><figcaption class=\"lm-cap\">\u73b0\u573a\u52d8\u6d4b<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">02<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u8bbe\u8ba1<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6839\u636e\u52d8\u6d4b\u6570\u636e\u8ba1\u7b97\u70ed\u8d1f\u8377\uff0c\u7ed8\u5236\u76d8\u7ba1\u5e03\u7f6e\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u56fe\u3001\u4e3b\u673a\u5206\u533a\u56fe\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u8bbe\u8ba1\u56fe\u7eb8\u7ecf\u5ba2\u6237\u786e\u8ba4\u540e\u65bd\u5de5<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-vamzrftsllgxtylt-1.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u7cfb\u7edf\u8bbe\u8ba1\u65b9\u6848\"><figcaption class=\"lm-cap\">\u7cfb\u7edf\u8bbe\u8ba1\u65b9\u6848<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">03<\/span><div class=\"lm-cs-title\">\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6240\u6709\u7ba1\u6750\u3001\u4fdd\u6e29\u6750\u6599\u4e0e\u5ba2\u6237\u5171\u540c\u6838\u9a8c\u54c1\u724c\u578b\u53f7\u89c4\u683c\uff0c\u94dc\u7ba1\u58c1\u539a\u9010\u6839\u6d4b\u91cf\u7559\u75d5\uff0c\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u5373\u9a8c\u6536\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\uff0c\u7559\u5b58\u6750\u6599\u7167\u7247<\/div>\n        <div class=\"lm-cs-imgs\">\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536\"><figcaption class=\"lm-cap\">\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c\"><figcaption class=\"lm-cap\">\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c<\/figcaption><\/figure>\n        <\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">04<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u5b89\u88c5<\/div><\/div>\n        <div class=\"lm-cs-body\">\u94dc\u7ba1\u710a\u63a5\uff08\u5145\u6c2e\u4fdd\u62a4\uff09\u3001\u5206\u6b67\u7ba1\u5b89\u88c5\u3001\u4fdd\u6e29\u5305\u88f9\u3001\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u3001\u6253\u538b\u6d4b\u8bd5\u3002\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\u56fa\u5b9a\uff0c\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\u6392\u5e03\u5e76\u8bbe\u6392\u6c14\u5b54\u3001\u6807\u51c6\u63a5\u5165\u5730\u6f0f\uff0c\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\u3001\u6c2e\u6c14\u4fdd\u538b\u5168\u7a0b\u7559\u75d5\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u6253\u538b 0.6-0.8MPa\uff0c\u7a33\u538b\u22651h\uff0c\u538b\u964d\u22640.05MPa<\/div>\n        <div class=\"lm-cs-imgs\">\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\"><figcaption class=\"lm-cap\">\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\"><figcaption class=\"lm-cap\">\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\"><figcaption class=\"lm-cap\">\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure>\n        <\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">05<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u8c03\u8bd5<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6ce8\u6c34\u6392\u6c14\u3001\u8054\u52a8\u903b\u8f91\u9a8c\u8bc1\u3001\u5404\u56de\u8def\u6d41\u91cf\u5747\u5300\u6027\u8c03\u8bd5\uff0c\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\u786e\u4fdd\u8fd0\u884c\u53c2\u6570\u8fbe\u6807\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5404\u623f\u95f4\u6e29\u5dee\u22642\u2103<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\"><figcaption class=\"lm-cap\">\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">06<\/span><div class=\"lm-cs-title\">\u7ae3\u5de5\u9a8c\u6536<\/div><\/div>\n        <div class=\"lm-cs-body\">\u9690\u853d\u5de5\u7a0b\u5f71\u50cf\u5f52\u6863\uff0c\u9010\u9879\u9a8c\u6536\u7b7e\u5b57\uff0c\u4ea4\u4ed8\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u3002\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\u4f5c\u4e3a\u9a8c\u6536\u51ed\u8bc1\u5b58\u6863\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5f71\u50cf\u6863\u6848 + \u9a8c\u6536\u8bb0\u5f55 + \u4f7f\u7528\u624b\u518c<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\"><figcaption class=\"lm-cap\">\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">+1<\/span><div class=\"lm-cs-title\">\u4ea4\u4ed8\u6559\u5b66<\/div><\/div>\n        <div class=\"lm-cs-body\">\u4e00\u5bf9\u4e00\u73b0\u573a\u8bbe\u5907\u6559\u5b66\uff0c\u6559\u4f1a\u6e29\u63a7\u5668\u4f7f\u7528\u3001\u6a21\u5f0f\u5207\u6362\u3001\u7d27\u6025\u64cd\u4f5c\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5ba2\u6237\u80fd\u72ec\u7acb\u64cd\u4f5c<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u57ce\u5357\u5b98\u90b8\u00b7\u7cbe\u5de5\u516d\u6b65\u6cd5\u00b7\u73b0\u573a\u8bbe\u5907\u6559\u5b66\"><figcaption class=\"lm-cap\">\u73b0\u573a\u8bbe\u5907\u6559\u5b66<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">+2<\/span><div class=\"lm-cs-title\">\u552e\u540e\u4fdd\u969c<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6bcf\u5e74\u91c7\u6696\u5b63\u56de\u8bbf\u91c7\u96c6\u6570\u636e\uff0c\u540c\u6237\u578b\u5bf9\u6807\u5206\u6790\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/div>\n      <\/div>\n    <\/div>\n    <button class=\"lm-car-arrow lm-prev\" onclick=\"lmCarGo(lmCarCur-1)\" aria-label=\"\u4e0a\u4e00\u6b65\">\u2039<\/button>\n    <button class=\"lm-car-arrow lm-next\" onclick=\"lmCarGo(lmCarCur+1)\" aria-label=\"\u4e0b\u4e00\u6b65\">\u203a<\/button>\n    <div class=\"lm-car-dots\" id=\"lmCarDots\"><\/div>\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u9690\u853d\u5de5\u7a0b\u53ef\u89c6\u5316<\/h3>\n  <div class=\"lm-highlight-blue\">\u6bcf\u4e2a\u65bd\u5de5\u73af\u8282\u62cd\u7167\u5b58\u6863\uff0c\u5f62\u6210\u5b8c\u6574\u7684\u65bd\u5de5\u5f71\u50cf\u6863\u6848\u3002\u6731\u8001\u5e08\u53ef\u901a\u8fc7\u624b\u673a\u968f\u65f6\u67e5\u770b\u5de5\u5730\u8fdb\u5ea6\u548c\u9690\u853d\u5de5\u7a0b\u5b9e\u51b5\uff0c\u505a\u5230&#8221;\u770b\u4e0d\u89c1\u7684\u5730\u65b9\u4e5f\u653e\u5fc3&#8221;\u3002<\/div>\n<\/section>\n\n<!-- ===== S4\u00b7\u900f\u660e\u62a5\u4ef7 ===== -->\n<section class=\"lm-section\" id=\"s4\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S4<\/span>\u900f\u660e\u62a5\u4ef7<\/div>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:16px;\">\u4ef7\u683c\u6765\u6e90\uff1a<a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=662\" target=\"_blank\">\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93V5.0\uff08longmai-nt.com\/?page_id=662\uff09<\/a>\u3002\u6298\u6263\u89c4\u5219\uff1a\u6c34\u5885\u9002\uff08\u96f6\u552e\u4ef7\uff09\u4e0d\u6253\u6298\uff1b\u5c0a\u777f\u5168\u6548\uff08\u9762\u4ef7\uff098.5\u6298\uff1b\u65b0\u98ce\u6309\u9762\u4ef7\u8ba1\uff08\u4e0d\u6253\u6298\uff09\uff1b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\uff08\u5355\u4ef7\uff09\u4e0d\u6253\u6298\uff1b\u5730\u6696\u7cfb\u7edf179\u5143\/\u33a1\u6253\u5305\u4e0d\u6253\u6298\u3002\u4ee5\u4e0b\u62a5\u4ef7\u4e3a\u8bbe\u5907+\u5b89\u88c5\u8d39\u5408\u8ba1\uff0c\u5747\u5f15\u81ea\u4e0a\u8ff0\u4ef7\u683c\u6e90\uff0c\u672a\u81ea\u884c\u7f16\u9020\u3002<\/p>\n\n  <!-- \u65b9\u6848\u4e00 -->\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u65b9\u6848\u4e00\uff1a\u539f\u59cb\u60f3\u6cd5\u9700\u6c42\u65b9\u6848\uff08\u6c34\u5885\u9002FX\u4e8c\u8054\u4f9b \u00b7 \u5168\u5c4b\u8d1f2F-4F\uff09<\/h3>\n  <h4 style=\"margin:12px 0 6px;color:var(--lm-gold2);\">1. \u5ba4\u5916\u673a\uff08\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u96f6\u552e\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u6c34\u5885\u9002FX\u5916\u673a \u00d72<\/td><td>RAS-252FPUENY2Q\/M<\/td><td>44,500\u00d72 = 89,000<\/td><td>4,000\u00d72 = 8,000<\/td><td>97,000<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"5\">\u5916\u673a\u5c0f\u8ba1\uff08220\u4ee5\u4e0a\u6863\u5b89\u88c5\u8d394,000\/\u5957\uff09<\/td><td>97,000<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">2. \u5ba4\u5185\u673a\uff08\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\u00b7\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u533a\u57df<\/th><th>\u578b\u53f7<\/th><th>\u96f6\u552e\u4ef7<\/th><th>\u6570\u91cf<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u8d1f2\u5065\u8eab\u533a<\/td><td>RFP-68WAR<\/td><td>2,800<\/td><td>1<\/td><td>2,800<\/td><\/tr>\n    <tr><td>2<\/td><td>\u8d1f2\u978b\u5e3d\u533a<\/td><td>RFP-102WAR<\/td><td>3,136<\/td><td>1<\/td><td>3,136<\/td><\/tr>\n    <tr><td>3<\/td><td>\u8d1f1\u5a31\u4e50\u5ba4<\/td><td>RFP-119WAR<\/td><td>3,500<\/td><td>1<\/td><td>3,500<\/td><\/tr>\n    <tr><td>4<\/td><td>\u8d1f1\u963f\u59e8\u623f<\/td><td>RFP-34WAR<\/td><td>2,625<\/td><td>1<\/td><td>2,625<\/td><\/tr>\n    <tr><td>5<\/td><td>1F\u5ba2\u9910\u5385<\/td><td>RFP-153WAR<\/td><td>4,930<\/td><td>2<\/td><td>9,860<\/td><\/tr>\n    <tr><td>6<\/td><td>2F\u7236\u6bcd\u623f<\/td><td>RFP-119WAR<\/td><td>3,500<\/td><td>1<\/td><td>3,500<\/td><\/tr>\n    <tr><td>7<\/td><td>2F\u6b21\u5367<\/td><td>RFP-136WAR<\/td><td>4,700<\/td><td>1<\/td><td>4,700<\/td><\/tr>\n    <tr><td>8<\/td><td>3F\u7537\u5b69\u623f<\/td><td>RFP-136WAR<\/td><td>4,700<\/td><td>1<\/td><td>4,700<\/td><\/tr>\n    <tr><td>9<\/td><td>3F\u5973\u513f\u623f<\/td><td>RFP-136WAR<\/td><td>4,700<\/td><td>1<\/td><td>4,700<\/td><\/tr>\n    <tr><td>10<\/td><td>4F\u4e3b\u5367<\/td><td>RFP-85WAR<\/td><td>3,086<\/td><td>1<\/td><td>3,086<\/td><\/tr>\n    <tr><td>11<\/td><td>4F\u8863\u5e3d\u95f4<\/td><td>RFP-34WAR<\/td><td>2,625<\/td><td>1<\/td><td>2,625<\/td><\/tr>\n    <tr><td>12<\/td><td>4F\u79c1\u57df\u7a7a\u95f4<\/td><td>RFP-68WAR<\/td><td>2,800<\/td><td>1<\/td><td>2,800<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"5\">\u5ba4\u5185\u673a\u5c0f\u8ba1\uff0813\u53f0\uff0c\u5b89\u88c5\u542b\u4e8e\u6c34\u7cfb\u7edf\u6574\u4f53\u65bd\u5de5\uff09<\/td><td>48,032<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">3. \u65b0\u98ce\u7cfb\u7edf<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\uff08\u8d1f1-\u8d1f2\u5171\u7528\uff09<\/td><td>KPI-3521Q7\/FH<\/td><td>17,500<\/td><td>7,000<\/td><td>24,500<\/td><\/tr>\n    <tr><td>2<\/td><td>\u5355\u5411\u6d41\u65b0\u98ce\uff081-4F\u54041\u53f0\uff09<\/td><td>FM-350H2<\/td><td>1,463<\/td><td>3,200<\/td><td>4,663\u00d74 = 18,652<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"5\">\u65b0\u98ce\u5c0f\u8ba1<\/td><td>43,152<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">4. \u5730\u6696\u7cfb\u7edf\uff08\u6c34\u673a\u70ed\u6cf5\u5730\u6696 \u00b7 \u65e0\u72ec\u7acb\u9505\u7089\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7<\/th><th>\u9762\u79ef\/\u6570\u91cf<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>\u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\u5730\u6696<\/td><td>\u4f1f\u661f\u7ba1+\u66fc\u745e\u5fb7\u8054\u52a8+\u4fdd\u6e29\u56de\u586b<\/td><td>179\u5143\/\u33a1<\/td><td>483.6\u33a1<\/td><td>86,564<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"4\">\u5730\u6696\u5c0f\u8ba1\uff08\u70ed\u6e90\u7531\u6c34\u5885\u9002\u4e3b\u673a\u70ed\u6cf5\u63d0\u4f9b\uff0c\u4e0d\u53e6\u914d\u9505\u7089\uff09<\/td><td>86,564<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">5. \u65b9\u6848\u4e00\u6c47\u603b<\/h4>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:60%;\">\u9879\u76ee<\/th><th style=\"width:40%;\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u673a\uff082\u00d7RAS-252\uff09<\/td><td>97,000<\/td><\/tr>\n    <tr><td>\u5ba4\u5185\u673a\uff0813\u53f0\u98ce\u673a\u76d8\u7ba1\uff09<\/td><td>48,032<\/td><\/tr>\n    <tr><td>\u65b0\u98ce\u7cfb\u7edf\uff08\u9664\u6e7f\u65b0\u98ce+\u5355\u5411\u6d41\u00d74\uff09<\/td><td>43,152<\/td><\/tr>\n    <tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u9f99\u8109179\u00b7\u70ed\u6cf5\u5730\u6696\u00b7\u65e0\u9505\u7089\uff09<\/td><td>86,564<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u65b9\u6848\u4e00 \u8bbe\u5907\u5408\u8ba1<\/td><td>274,748<\/td><\/tr>\n  <\/table>\n\n  <!-- \u65b9\u6848\u4e8c -->\n  <h3 style=\"margin:28px 0 12px;color:var(--lm-gold2);\">\u65b9\u6848\u4e8c\uff1a\u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848\uff08\u5c0a\u777f\u5168\u6548 + \u6c34\u6a21\u5757 \u4e8c\u8054\u4f9b\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u4ef7\u683c\u6765\u6e90\uff1a\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93V5.0 \uff5c \u5c0a\u777f\u5168\u6548\uff08\u9762\u4ef7\u00b78.5\u6298\uff09\uff5c \u6c34\u6a21\u5757\uff08\u9762\u4ef7\u00b78.5\u6298\uff09<\/p>\n\n  <h4 style=\"margin:12px 0 6px;color:var(--lm-gold2);\">1. \u5ba4\u5916\u673a + \u6c34\u6a21\u5757<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>8.5\u6298<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u5c0a\u777f\u5168\u6548224\uff08\u8d1f2-1F\uff09<\/td><td>RAS-224FSXPN5Q<\/td><td>29,300<\/td><td>24,905<\/td><td>600<\/td><td>25,505<\/td><\/tr>\n    <tr><td>2<\/td><td>\u5c0a\u777f\u5168\u6548280\uff082-4F\uff09<\/td><td>RAS-280FSXPNY5Q<\/td><td>34,788<\/td><td>29,570<\/td><td>600<\/td><td>30,170<\/td><\/tr>\n    <tr><td>3<\/td><td>\u6c34\u6a21\u5757224<\/td><td>RWMG-224FWXNZQ<\/td><td>9,750<\/td><td>8,288<\/td><td>625<\/td><td>8,913<\/td><\/tr>\n    <tr><td>4<\/td><td>\u6c34\u6a21\u5757280<\/td><td>RWMG-280FWXNZQ<\/td><td>11,250<\/td><td>9,563<\/td><td>625<\/td><td>10,188<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\">\u4e3b\u673a+\u6c34\u6a21\u5757\u5c0f\u8ba1<\/td><td>74,776<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">2. \u5ba4\u5185\u673a\uff08\u5c0a\u777f\u5168\u6548\u00b7\u9762\u4ef7\u00b78.5\u6298\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u533a\u57df<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>8.5\u6298<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u8d1f2\u5065\u8eab\uff08\u4e09\u7ba1\u5236\uff09<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>5,050<\/td><td>4,293<\/td><td>1,900<\/td><td>6,193<\/td><\/tr>\n    <tr><td>2<\/td><td>\u8d1f2\u978b\u5e3d\uff08\u4e09\u7ba1\u5236\uff09<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5,663<\/td><td>4,814<\/td><td>1,900<\/td><td>6,714<\/td><\/tr>\n    <tr><td>3<\/td><td>\u8d1f1\u5a31\u4e50\uff08\u4e09\u7ba1\u5236\uff09<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>5,563<\/td><td>4,729<\/td><td>1,900<\/td><td>6,629<\/td><\/tr>\n    <tr><td>4<\/td><td>\u8d1f1\u963f\u59e8\uff08\u4e09\u7ba1\u5236\uff09<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>5,050<\/td><td>4,293<\/td><td>1,900<\/td><td>6,193<\/td><\/tr>\n    <tr><td>5<\/td><td>1F\u5ba2\u9910\u5385\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-71FSVNZ1QD\/PC<\/td><td>5,238<\/td><td>4,452<\/td><td>1,600<\/td><td>6,052<\/td><\/tr>\n    <tr><td>6<\/td><td>1F\u5ba2\u9910\u5385\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5,088<\/td><td>4,325<\/td><td>1,600<\/td><td>5,925<\/td><\/tr>\n    <tr><td>7<\/td><td>2F\u7236\u6bcd\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5,088<\/td><td>4,325<\/td><td>1,600<\/td><td>5,925<\/td><\/tr>\n    <tr><td>8<\/td><td>2F\u6b21\u5367\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5,088<\/td><td>4,325<\/td><td>1,600<\/td><td>5,925<\/td><\/tr>\n    <tr><td>9<\/td><td>3F\u7537\u5b69\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5,088<\/td><td>4,325<\/td><td>1,600<\/td><td>5,925<\/td><\/tr>\n    <tr><td>10<\/td><td>3F\u5973\u5b69\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5,088<\/td><td>4,325<\/td><td>1,600<\/td><td>5,925<\/td><\/tr>\n    <tr><td>11<\/td><td>4F\u4e3b\u5367+\u8fc7\u9053\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-56FSVNZ1QD\/PC<\/td><td>5,088<\/td><td>4,325<\/td><td>1,600<\/td><td>5,925<\/td><\/tr>\n    <tr><td>12<\/td><td>4F\u8863\u5e3d\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-22FSVNZ1QD\/PC<\/td><td>4,600<\/td><td>3,910<\/td><td>1,600<\/td><td>5,510<\/td><\/tr>\n    <tr><td>13<\/td><td>4F\u79c1\u57df\uff08\u4e8c\u7ba1\u5236\uff09<\/td><td>RPIZ-32FSVNZ1QD\/PC<\/td><td>4,800<\/td><td>4,080<\/td><td>1,600<\/td><td>5,680<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\">\u5ba4\u5185\u673a\u5c0f\u8ba1\uff0813\u53f0\uff09<\/td><td>78,521<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">3. \u65b0\u98ce\u7cfb\u7edf<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u4e91\u51c0\u666e\u901a\u5168\u70ed\u4ea4\u6362\uff08\u8d1f1-\u8d1f2\u5171\u7528\uff09<\/td><td>KPI-3521Q3A\/F<\/td><td>6,200<\/td><td>6,000<\/td><td>12,200<\/td><\/tr>\n    <tr><td>2<\/td><td>\u5355\u5411\u6d41\u65b0\u98ce\uff081-4F\u54041\u53f0\uff09<\/td><td>FM-350H2<\/td><td>1,463<\/td><td>3,200<\/td><td>4,663\u00d74 = 18,652<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"5\">\u65b0\u98ce\u5c0f\u8ba1<\/td><td>30,852<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">4. \u5730\u6696\u7cfb\u7edf\uff08\u6c34\u6a21\u5757\u70ed\u6cf5\u5730\u6696 \u00b7 \u65e0\u72ec\u7acb\u9505\u7089\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7<\/th><th>\u9762\u79ef\/\u6570\u91cf<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>\u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\u5730\u6696<\/td><td>179\u5143\/\u33a1<\/td><td>179\u5143\/\u33a1<\/td><td>483.6\u33a1<\/td><td>86,564<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"4\">\u5730\u6696\u5c0f\u8ba1\uff08\u70ed\u6e90\u7531\u6c34\u6a21\u5757\u70ed\u6cf5\u63d0\u4f9b\uff0c\u4e0d\u53e6\u914d\u9505\u7089\uff09<\/td><td>86,564<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">5. \u65b9\u6848\u4e8c\u6c47\u603b<\/h4>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:60%;\">\u9879\u76ee<\/th><th style=\"width:40%;\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u673a+\u6c34\u6a21\u5757<\/td><td>74,776<\/td><\/tr>\n    <tr><td>\u5ba4\u5185\u673a\uff0813\u53f0\uff09<\/td><td>78,521<\/td><\/tr>\n    <tr><td>\u65b0\u98ce\u7cfb\u7edf<\/td><td>30,852<\/td><\/tr>\n    <tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u9f99\u8109179\u00b7\u70ed\u6cf5\u5730\u6696\u00b7\u65e0\u9505\u7089\uff09<\/td><td>86,564<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u65b9\u6848\u4e8c \u8bbe\u5907\u5408\u8ba1<\/td><td>270,713<\/td><\/tr>\n  <\/table>\n\n  <!-- \u65b9\u6848\u4e09 -->\n  <h3 style=\"margin:28px 0 12px;color:var(--lm-gold2);\">\u65b9\u6848\u4e09\uff1a20\u5e74\u957f\u6548\u4f18\u9009\u65b9\u6848\uff08\u5c0a\u777f\u5168\u6548 \u4e2d\u592e\u7a7a\u8c03\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:8px;\">\u5ba4\u5185\u673a\/\u5916\u673a\/\u65b0\u98ce\u914d\u7f6e\u4e0e\u65b9\u6848\u4e8c\u5b8c\u5168\u4e00\u81f4\uff0c\u4ec5\u53bb\u6389\u4e24\u53f0\u6c34\u6a21\u5757\uff1b\u5730\u6696\u70ed\u6e90\u7531 <strong style=\"color:var(--lm-gold2);\">2\u00d7\u83f2\u65af\u66fc24kW \u51b7\u51dd\u7089\u5e76\u673a<\/strong>\u627f\u62c5\uff08\u65b9\u6848\u4e00\/\u4e8c\u5219\u7531\u6c34\u673a\/\u6c34\u6a21\u5757\u70ed\u6cf5\u627f\u62c5\uff0c\u4e0d\u53e6\u914d\u9505\u7089\uff0c\u6545\u672c\u65b9\u6848\u662f\u552f\u4e00\u9700\u8981\u83f2\u65af\u66fc\u9505\u7089\u7684\u65b9\u6848\uff09\u3002<\/p>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:60%;\">\u9879\u76ee<\/th><th style=\"width:40%;\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u673a\uff08224+280\uff09<\/td><td>55,675<\/td><\/tr>\n    <tr><td>\u5ba4\u5185\u673a\uff0813\u53f0\uff0c\u540c\u65b9\u6848\u4e8c\uff09<\/td><td>78,521<\/td><\/tr>\n    <tr><td>\u65b0\u98ce\u7cfb\u7edf\uff08\u4e91\u51c0+\u5355\u5411\u6d41\u00d74\uff09<\/td><td>30,852<\/td><\/tr>\n    <tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u9505\u7089\u00d72+\u9f99\u8109179\u7cfb\u7edf\uff09<\/td><td>114,958<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u65b9\u6848\u4e09 \u8bbe\u5907\u5408\u8ba1<\/td><td>280,006<\/td><\/tr>\n  <\/table>\n\n  <!-- \u4e09\u65b9\u6848\u5bf9\u6bd4 -->\n  <h3 style=\"margin:28px 0 12px;color:var(--lm-gold2);\">\u4e09\u65b9\u6848\u603b\u6295\u5165\u5bf9\u6bd4<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u6784\u6210<\/th><th>\u65b9\u6848\u4e00 \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th>\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/th><th>\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03<\/th><\/tr>\n    <tr><td>\u7a7a\u8c03\u4e3b\u673a+\u5185\u673a<\/td><td>145,032<\/td><td>153,297<\/td><td>134,196<\/td><\/tr>\n    <tr><td>\u65b0\u98ce\u7cfb\u7edf<\/td><td>43,152<\/td><td>30,852<\/td><td>30,852<\/td><\/tr>\n    <tr><td>\u5730\u6696\uff08\u70ed\u6cf5\u5730\u6696 \/ \u7cfb\u7edf+\u9505\u7089\uff09<\/td><td>86,564<\/td><td>86,564<\/td><td>114,958<\/td><\/tr>\n    <tr><td>\u4e8c\u8054\u4f9b\/\u9664\u6e7f\u7ec4\u4ef6<\/td><td>\uff08\u6c34\u673a\u81ea\u5e26\uff09<\/td><td>19,101<\/td><td>\u2014<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u603b\u6295\u5165<\/td><td>274,748<\/td><td>270,713<\/td><td>280,006<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-chart-box\">\n    <div class=\"lm-chart-title\">\u4e09\u65b9\u6848\u603b\u6295\u5165\u6784\u6210\u5bf9\u6bd4\uff08\u5143\uff09<\/div>\n    <div class=\"lm-chart\" id=\"lmPlanChart\"><\/div>\n  <\/div>\n\n  <h3 style=\"margin:28px 0 12px;color:var(--lm-gold2);\">\u4e09\u65b9\u6848 20 \u5e74\u5168\u5468\u671f\u603b\u6295\u5165\u5bf9\u6bd4<\/h3>\n  <p style=\"font-size:13px;color:var(--lm-text2);margin-bottom:12px;\">\u70b9\u51fb\u5361\u7247\u53ef\u7ffb\u8f6c\u67e5\u770b\u660e\u7ec6\u3002<strong style=\"color:var(--lm-gold2);\">\u6b63\u9762<\/strong>\u4e3a 20 \u5e74\u7d2f\u8ba1\u6295\u5165\u8d8b\u52bf\uff08\u521d\u6295\u8d44 + \u5e74\u8fd0\u884c\u8d39\u00d720\uff0c\u4e0d\u8ba1\u5165\u80fd\u6e90\u6da8\u4ef7\u4e0e\u8bbe\u5907\u66f4\u6362\uff09\uff1b<strong style=\"color:var(--lm-gold2);\">\u80cc\u9762<\/strong>\u4e3a\u5404\u9879\u660e\u7ec6\u4e0e\u4f30\u7b97\u5047\u8bbe\u3002<br><span style=\"color:#a07b2a;\">\u6ce8\uff1a\u5e74\u8fd0\u884c\u8d39\u4e3a\u57fa\u4e8e\u6210\u90fd\u6c14\u5019\u4e0e\u73b0\u884c\u7535\/\u6c14\u4ef7\u7684\u5de5\u7a0b\u4f30\u7b97\uff08\u975e\u5b9e\u6d4b\uff09\uff0c\u4ec5\u7528\u4e8e\u65b9\u6848\u95f4\u76f8\u5bf9\u6bd4\u8f83\u3002<\/span><\/p>\n  <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('lm-flip-open')\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\">\n        <div class=\"lm-flip-tag\">\u6b63\u9762 \u00b7 20 \u5e74\u7d2f\u8ba1\u603b\u6295\u5165\u8d8b\u52bf<\/div>\n        <div class=\"lm-chart\" id=\"lm20Chart\"><\/div>\n        <div class=\"lm-flip-hint\">\u21bb \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b 20 \u5e74\u660e\u7ec6<\/div>\n      <\/div>\n      <div class=\"lm-flip-back\">\n        <div class=\"lm-flip-tag\">\u80cc\u9762 \u00b7 20 \u5e74\u603b\u6295\u5165\u660e\u7ec6\uff08\u4f30\u7b97\uff09<\/div>\n        <table class=\"lm-table\">\n          <tr><th>\u9879\u76ee<\/th><th>\u65b9\u6848\u4e00 \u6c34\u5885\u9002<\/th><th>\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757<\/th><th>\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03<\/th><\/tr>\n          <tr><td>\u521d\u6295\u8d44\uff08\u8bbe\u5907+\u5b89\u88c5\uff09<\/td><td>274,748<\/td><td>270,713<\/td><td>280,006<\/td><\/tr>\n          <tr><td>\u5e74\u8fd0\u884c\u8d39\uff08\u4f30\u7b97\uff09<\/td><td>\u224811,990<\/td><td>\u224811,190<\/td><td>\u224814,239<\/td><\/tr>\n          <tr><td>20 \u5e74\u8fd0\u884c\u8d39<\/td><td>\u2248239,800<\/td><td>\u2248223,800<\/td><td>\u2248284,800<\/td><\/tr>\n          <tr class=\"lm-row-hl\"><td>20 \u5e74\u603b\u6295\u5165<\/td><td>\u2248514,500<\/td><td>\u2248494,500<\/td><td>\u2248564,800<\/td><\/tr>\n        <\/table>\n        <p style=\"font-size:12px;color:var(--lm-text2);margin-top:10px;line-height:1.7;\">\u4f30\u7b97\u5047\u8bbe\uff1a\u7535\u4ef7 0.55 \u5143\/kWh\u3001\u6c14\u4ef7 2.8 \u5143\/m\u00b3\uff1b\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\u70ed\u9700\u6c42\u7ea6 32,000 kWh\/\u5e74\uff08\u65b9\u6848\u4e09\u71c3\u6c14\u7089\u6548\u7387 0.95\uff0c\u65b9\u6848\u4e00\/\u4e8c\u70ed\u6cf5 COP\u22483.3\uff09\uff1b\u5236\u51b7\u7ea6 22,000 kWh\u51b7\/\u5e74\uff08EER\u22483.5\uff09\uff1b\u65b0\u98ce\u9664\u6e7f\u5e74\u7535\u8d39\uff1a\u65b9\u6848\u4e00(\u5929\u51c0\u9664\u6e7f)\u22483,200\u3001\u65b9\u6848\u4e8c(\u4e91\u51c0+\u7a7a\u8c03\u6e29\u6e7f\u53cc\u63a7)\u22482,400\u3001\u65b9\u6848\u4e09(\u4e91\u51c0)\u22481,800\u3002\u672a\u8ba1\u5165\u80fd\u6e90\u6da8\u4ef7\u4e0e\u8bbe\u5907\u66f4\u6362\uff1b\u65b9\u6848\u4e09\u71c3\u6c14\u7089\u7ea6 12\u201315 \u5e74\u53ef\u80fd\u9700\u66f4\u6362\uff0c\u5c06\u62c9\u5927\u5dee\u8ddd\u3002<\/p>\n        <div class=\"lm-flip-hint\">\u21bb \u70b9\u51fb\u7ffb\u8f6c\u56de\u56fe\u8868<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u4ef7\u683c\u8bf4\u660e\uff1a<\/strong><br>\n    1. \u4ee5\u4e0a\u4ef7\u683c\u4e3a\u8bbe\u5907+\u5b89\u88c5\u8d39\u5408\u8ba1\uff0c\u6309\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee402 V5.0\uff08longmai-nt.com\/?page_id=662\uff09\u6267\u884c\uff1b<br>\n    2. \u6c34\u5885\u9002\u7cfb\u5217\u4e3a\u96f6\u552e\u4ef7\uff0c\u4e0d\u6253\u6298\uff1b\u5c0a\u777f\u5168\u6548\u7cfb\u5217\u4e3a\u9762\u4ef7\uff0c\u4eab8.5\u6298\uff1b\u6c34\u6a21\u5757\u4e3a\u5c0a\u777f\u9762\u4ef7\u4ea7\u54c1\uff0c\u4eab8.5\u6298\uff1b<br>\n    3. \u65b0\u98ce\u7cfb\u7edf\u6309\u9762\u4ef7\u8ba1\uff08\u4e0d\u6253\u6298\uff09\uff1b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e3a\u5355\u4ef7\u4ea7\u54c1\uff08\u4e0d\u6253\u6298\uff09\uff1b\u5730\u6696\u7cfb\u7edf179\u5143\/\u33a1\u6253\u5305\u4e0d\u6253\u6298\uff1b<br>\n    4. <strong>\u5730\u6696\u70ed\u6e90\u8bf4\u660e<\/strong>\uff1a\u65b9\u6848\u4e00\uff08\u6c34\u5885\u9002\u4e8c\u8054\u4f9b\uff09\u5730\u6696\u70ed\u6e90\u7531\u6c34\u673a\u70ed\u6cf5\u627f\u62c5\u3001\u65b9\u6848\u4e8c\uff08\u5c0a\u777f+\u6c34\u6a21\u5757\uff09\u7531\u6c34\u6a21\u5757\u70ed\u6cf5\u627f\u62c5\uff0c\u4e24\u8005<strong>\u5747\u4e0d\u53e6\u914d\u83f2\u65af\u66fc\u9505\u7089<\/strong>\uff0c\u5730\u6696\u7cfb\u7edf\u4ec5\u8ba1\u9f99\u8109179\u5143\/\u33a1\uff0886,564\u5143\uff09\uff1b\u4ec5\u65b9\u6848\u4e09\uff08\u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03\u00b7\u65e0\u6c34\u6a21\u5757\uff09\u5730\u6696\u70ed\u6e90\u7531 2\u00d7\u83f2\u65af\u66fc24kW \u51b7\u51dd\u7089\u5e76\u673a\u627f\u62c5\uff0c\u5730\u6696\u8ba1 86,564+28,394 = 114,958\u5143\u3002<br>\n    5. \u6c34\u5885\u9002\u98ce\u673a\u76d8\u7ba1\u5b89\u88c5\u8d39\u542b\u4e8e\u6c34\u7cfb\u7edf\u6574\u4f53\u65bd\u5de5\uff08\u6e90\u672a\u5355\u5217\uff09\uff0c\u4e3b\u673a\u5b89\u88c5\u8d39\u6309220\u4ee5\u4e0a\u68634,000\/\u5957\u5355\u5217\uff1b<br>\n    6. \u672c\u62a5\u4ef7\u4e0d\u542b\u540a\u88c5\u8d39\u3001\u8fdc\u7a0b\u8d39\u3001\u7a0e\u91d1\u53ca\u4e3b\u673a\u7535\u6e90\u7ebf\/\u7a7a\u5f00\/\u5916\u673a\u652f\u67b6\uff0c\u4ee5\u5b9e\u9645\u7b7e\u7ea6\u786e\u8ba4\u4e3a\u51c6\uff0c\u6709\u6548\u671f30\u5929\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355<\/h3>\n  <p style=\"color:var(--lm-text2);margin-bottom:12px;font-size:14px;\">\u4ee5\u4e0b\u8f85\u6750\u6e05\u5355\u6309\u6307\u4ee406\u89c4\u8303\u8f93\u51fa\uff0c\u4ec5\u5217\u54c1\u724c\u89c4\u683c\uff0c\u4e0d\u542b\u4ef7\u683c\u3002\u70b9\u51fb\u5c55\u5f00\u67e5\u770b\u3002<\/p>\n\n  <div class=\"lm-acc\">\n    <div class=\"lm-acc-item lm-open\">\n      <div class=\"lm-acc-head\">\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u5c0a\u777f\u5168\u6548\u00b7\u6c1f\u7cfb\u7edf\uff09<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1\uff0c\u8f93\u9001\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>15.88\/19.05\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><\/tr>\n          <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea615\/20mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n          <tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr>\n          <tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u6c34\u5885\u9002\u7cfb\u7edf\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u65b9\u6848\u4e00\u00b7\u6c34\u7cfb\u7edf\uff09<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35-19.05\u00d70.8\/1.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6c1f\u7cfb\u7edf\u51b7\u5a92\u7ba1<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u4e3d\u9a6c<\/td><td>PP-R\u4fdd\u6e29\u7ba1<\/td><td>De25\/32\/40<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6c34\u7cfb\u7edf\u4f9b\u56de\u6c34\u7ba1<\/td><\/tr>\n          <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279<\/td><td>\u4fdd\u6e29\u68c9<\/td><td>15\/20\/9mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u51b7\u6865\/\u51dd\u9732<\/td><\/tr>\n          <tr><td>\u5b9a\u5236<\/td><td>\u6c34\u529b\u5e73\u8861\u7ec4\u4ef6<\/td><td>\u538b\u5dee\u65c1\u901a\/\u52a8\u6001\u5e73\u8861\u9600<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6c34\u7cfb\u7edf\u6c34\u529b\u5e73\u8861<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\uff08\u4e3b\u7ba1\/\u5730\u9762\/\u63a7\u5236\uff09\u8f85\u6750<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u4e3b\u7ba1<\/td><td>dn32\/dn40\/dn50<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e3b\u7ba1<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u94dc\u8d28\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5206\u8def\u63a7\u5236<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f\/\u53cd\u5c04\u819c<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u6e29\/\u53cd\u5c04<\/td><\/tr>\n          <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u56de\u8def\u901a\u65ad<\/td><\/tr>\n          <tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\/\u8865\u6c34\u9600<\/td><td>DN20\/DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14\/\u8865\u6c34<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u65b0\u98ce\u7cfb\u7edf\u8f85\u6750<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>PE\u6ce2\u7eb9\u7ba1<\/td><td>\u03c6110\/\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u73af\u4fdd\u65e0\u83cc\u98ce\u7ba1<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>\u4e3b\u673a\u8fde\u63a5\u7ba1<\/td><td>\u03c6110<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5bc6\u5c01\u9632\u5c18\u964d\u566a<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>ABS\u53ef\u8c03\u98ce\u53e3<\/td><td>\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9001\u56de\u98ce\u53e3<\/td><\/tr>\n          <tr><td>\u771f\u5982<\/td><td>304\u9632\u96e8\u98ce\u7f69<\/td><td>\u03c6120<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u96e8<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u670d\u52a1\u4fdd\u969c<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1\/\u51fa\u56fe\/\u5b9a\u4f4d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5382\u5bb6\u7b2c\u4e09\u65b9\u76d1\u7406+VR\u5168\u666f<\/td><\/tr>\n          <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-highlight-blue\" style=\"margin:16px 0;font-size:13px;\">\n    <strong>\u8f85\u6750\u8bf4\u660e\uff1a<\/strong><br>\n    1. \u4ee5\u4e0a\u8f85\u6750\u5747\u4e3a\u9ed8\u8ba4\u89c4\u683c\uff0c\u54c1\u724c\u4e0d\u53ef\u66ff\u6362\uff0c\u89c4\u683c\u4e0d\u53ef\u865a\u6784\uff1b<br>\n    2. \u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u6570\u91cf\u4ee5\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff1b<br>\n    3. \u8f85\u6750\u4e0d\u6d89\u53ca\u62a5\u4ef7\u91d1\u989d\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff1b<br>\n    4. \u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3001\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff1b<br>\n    5. \u5982\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u52a8\u7528\u540a\u88c5\u8bbe\u5907\uff0c\u8d39\u7528\u53e6\u8ba1\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== S5\u00b7\u6848\u4f8b\u9a8c\u8bc1 ===== -->\n<section class=\"lm-section\" id=\"s5\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S5<\/span>\u6848\u4f8b\u9a8c\u8bc1<\/div>\n\n  <table class=\"lm-table\">\n    <tr><th>\u6848\u4f8b<\/th><th>\u9762\u79ef<\/th><th>\u7cfb\u7edf\u914d\u7f6e<\/th><th>\u8fd0\u884c\u6570\u636e<\/th><th>\u53c2\u8003\u4ef7\u503c<\/th><\/tr>\n    <tr>\n      <td><a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=448\" target=\"_blank\">\u548c\u8d35\u5357\u5c71\u4e0a\u00b7\u8f9b\u603b\u522b\u5885<\/a><\/td>\n      <td>600\u33a1<\/td>\n      <td>\u65e5\u7acb\u5c0a\u777f504\u4e3b\u673a+\u745e\u7f8e\u53cc\u51b7\u51dd\u9505\u7089+15\u53f0\u5185\u673a<\/td>\n      <td>\u5730\u6696\u6708\u8d39\u4e0d\u52302000\u5143<\/td>\n      <td>\u522b\u5885\u5927\u5b85\u7cfb\u7edf\u6807\u6746<\/td>\n    <\/tr>\n    <tr>\n      <td><a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/case\/yufeng.html\" target=\"_blank\">\u84dd\u82b1\u6979\u00b7\u8a89\u5cf0\u5927\u5e73\u5c42<\/a><\/td>\n      <td>220\u33a1<\/td>\n      <td>24kW\u53d8\u9891\u7089+\u53bb\u8026\u7f50+\u5ba4\u6e29\u8054\u52a8\uff08\u8282\u80fd\u6539\u9020\uff09<\/td>\n      <td>\u8282\u80fd30%-50%<\/td>\n      <td>\u529f\u7387\u5339\u914d\u8282\u80fd\u9a8c\u8bc1<\/td>\n    <\/tr>\n    <tr>\n      <td><a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=540\" target=\"_blank\">\u9e93\u6e56\u751f\u6001\u57ce\u00b7\u5468\u8001\u5e08<\/a><\/td>\n      <td>98.8\u33a1\u91c7\u6696<\/td>\n      <td>\u745e\u7f8e\u53cc\u51b7\u51dd\u7089+\u4f1f\u661f\u7ba1\u9053+\u66fc\u745e\u5fb7\u8054\u52a8<\/td>\n      <td>\u91c7\u6696\u5b63\u6708\u71c3\u6c14\u8d39\u4f4e\u4e8e\u5e02\u573a\u5747\u503c<\/td>\n      <td>\u5168\u6d41\u7a0b\u6863\u6848\u6807\u6746<\/td>\n    <\/tr>\n  <\/table>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u65b9\u6848\u9a8c\u8bc1\u4e0e\u9009\u578b\u7ed3\u8bba<\/h3>\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u4e00\u53e5\u8bdd\u9009\u578b\u63a8\u8350\uff1a<\/strong>\u7efc\u5408\u8d1f\u8377\u6821\u6838\u3001\u8fde\u63a5\u7387\u3001\u5730\u4e0b\u5ba4\u9664\u6e7f\u8def\u5f84\u3001\u5730\u6696\u70ed\u6e90\u4e0e\u5168\u5468\u671f\u6210\u672c\uff0c<strong>\u63a8\u8350\u65b9\u6848\u4e8c\uff08\u6027\u4ef7\u6bd4\u63a8\u8350\u65b9\u6848 \u00b7 \u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff09<\/strong>\u2014\u2014\u521d\u6295270,713\u5143\u4e3a\u4e09\u65b9\u6848\u6700\u4f4e\u300120\u5e74\u603b\u6295\u5165\u7ea6494,500\u5143\u4e5f\u6700\u4f4e\uff0c\u4e14\u5730\u4e0b\u5ba4\u6e29\u6e7f\u53cc\u63a7\u7cbe\u51c6\u9664\u6e7f\uff0c\u7efc\u5408\u6027\u4ef7\u6bd4\u6700\u4f18\u3002\n  <\/div>\n\n  <h4 style=\"margin:18px 0 8px;color:var(--lm-gold2);\">AI \u9a8c\u8bc1\u6e05\u5355\uff08\u22655\u9879\uff09<\/h4>\n  <ul class=\"lm-checklist\">\n    <li><span class=\"lm-ck-ico\">\u2713<\/span><b>\u8d1f\u8377\u8ba1\u7b97\u6821\u6838\uff1a<\/b>483.6\u33a1\u00d780~120W\/\u33a1=38.7~58kW\uff0c\u4e3b\u673a\u603b\u80fd\u529b\u5408\u89c4\uff08\u65b9\u6848\u4e0044.8kW\uff1b\u65b9\u6848\u4e8c224+280\u5206\u533a\uff0c\u8fde\u63a5\u738793%\/96%\uff09\u3002<\/li>\n    <li><span class=\"lm-ck-ico\">\u2713<\/span><b>\u8fde\u63a5\u7387\u6821\u6838\uff1a<\/b>224\u4e3b\u673a\u8fde\u63a5\u738793%\u3001280\u4e3b\u673a\u8fde\u63a5\u738796%\uff0c\u5747\u843d\u572890~130%\u5408\u89c4\u533a\u95f4\uff0c\u5168\u5f00\u4e0d\u6253\u6298\u3001\u5355\u5f00\u4e0d\u9891\u7e41\u542f\u505c\u3002<\/li>\n    <li><span class=\"lm-ck-ico\">\u2713<\/span><b>\u5730\u4e0b\u5ba4\u9664\u6e7f\u8def\u5f84\uff1a<\/b>\u65b9\u6848\u4e8c\/\u4e09\u5c0a\u777f\u4e09\u7ba1\u5236\u4e0d\u964d\u6e29\u9664\u6e7f\u66f4\u7cbe\u51c6\uff1b\u65b9\u6848\u4e00\u9700\u989d\u5916\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\uff08\u72ec\u7acb\u9664\u6e7f\uff09\u3002<\/li>\n    <li><span class=\"lm-ck-ico\">\u2713<\/span><b>\u5730\u6696\u70ed\u6e90\uff1a<\/b>\u65b9\u6848\u4e00\/\u4e8c\u7531\u70ed\u6cf5\u627f\u62c5\uff08COP\u22653\u7701\u6c14\uff09\uff1b\u65b9\u6848\u4e09\u7531\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u627f\u62c5\uff0c20\u5e74\u8fd0\u884c\u8d39\u6700\u9ad8\u3002<\/li>\n    <li><span class=\"lm-ck-ico\">\u2713<\/span><b>\u4e09\u65b9\u6848\u5dee\u5f02\u5316\uff1a<\/b>\u65b9\u6848\u4e00\u6c34\u673a\u51fa\u98ce\u67d4\u548c+\u53cc\u673a\u5197\u4f59\uff1b\u65b9\u6848\u4e8c\u6c1f\u7cfb\u7edf\u7a33\u5b9a+\u70ed\u6cf5\u8282\u80fd\uff1b\u65b9\u6848\u4e09\u9505\u7089\u5730\u6696+\u521d\u6295\u6700\u9ad8\u3002<\/li>\n  <\/ul>\n\n  <h4 style=\"margin:18px 0 8px;color:var(--lm-gold2);\">\u516d\u7ef4\u5ea6\u7efc\u5408\u8bc4\u5206\uff08\u60ac\u505c\u7ffb\u8f6c\u770b\u8bc4\u5206\u4f9d\u636e\uff09<\/h4>\n  <div class=\"lm-score-grid\">\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u521d\u6295\u8d44<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:92%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:88%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u521d\u6295\u8d44\u8bc4\u5206<\/div>\n        <ul><li>\u65b9\u6848\u4e8c 270,713\u5143 \u6700\u4f4e\uff08\u542b\u70ed\u6cf5\u5730\u6696\uff09<\/li><li>\u65b9\u6848\u4e00 274,748\u5143 \u5c45\u4e2d<\/li><li>\u65b9\u6848\u4e09 280,006\u5143 \u6700\u9ad8\uff08\u9700\u8865\u9505\u7089\uff09<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u8fd0\u884c\u8d39<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:85%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:70%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u8fd0\u884c\u8d39\u8bc4\u5206<\/div>\n        <ul><li>\u65b9\u6848\u4e8c \u70ed\u6cf5\u5730\u6696COP\u22653 \u6700\u7701\u6c14<\/li><li>\u65b9\u6848\u4e00 \u6c34\u673a\u9ad8\u6548\u4f46\u9664\u6e7f\u65b0\u98ce\u8017\u7535\u504f\u9ad8<\/li><li>\u65b9\u6848\u4e09 \u5730\u6696\u5168\u71c3\u6c14 20\u5e74\u6700\u9ad8<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u8212\u9002\u5ea6<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:90%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:95%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:95%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u8212\u9002\u5ea6\u8bc4\u5206<\/div>\n        <ul><li>\u5c0a\u777f PE\u51c0\u5316+\u81ea\u6e05\u6d01+\u6e29\u6e7f\u53cc\u63a7 \u66f4\u4f18<\/li><li>\u6c34\u5885\u9002\u51fa\u98ce15-20\u2103\u66f4\u67d4\u548c<\/li><li>\u5730\u4e0b\u5ba4\u9632\u6f6e\u5c0a\u777f\u5185\u7f6e\u9664\u6e7f\u66f4\u7cbe\u51c6<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u7a33\u5b9a\u6027<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:80%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u7a33\u5b9a\u6027\u8bc4\u5206<\/div>\n        <ul><li>\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u5bc6\u5c01 \u65e0\u6f0f\u6c34\u98ce\u9669<\/li><li>\u6c34\u7cfb\u7edf\u63a5\u5934\u591a \u957f\u671f\u6f0f\u6c34\u98ce\u9669<\/li><li>\u65b9\u6848\u4e8c\/\u4e09 \u5206\u533a\u5355\u53f0\u6545\u969c\u5f71\u54cd\u534a\u5b85<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u7ef4\u62a4\u8d39<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:70%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u7ef4\u62a4\u8d39\u8bc4\u5206<\/div>\n        <ul><li>\u6c1f\u7cfb\u7edf \u81ea\u6e05\u6d01+\u5e74\u5ea6\u56de\u8bbf \u7ef4\u62a4\u4f4e<\/li><li>\u6c34\u7cfb\u7edf \u9700\u5b9a\u671f\u6e05\u6d17\/\u6392\u6c14\/\u8865\u6c34<\/li><li>\u7ef4\u62a4\u9700\u6c42\uff1a\u65b9\u6848\u4e8c\/\u4e09 \u4f4e \u00b7 \u65b9\u6848\u4e00 \u9ad8<\/li><\/ul><\/div>\n    <\/div><\/div>\n    <div class=\"lm-score-card\"><div class=\"lm-score-inner\">\n      <div class=\"lm-score-face lm-score-front\"><div class=\"lm-score-dim\">\u5bff\u547d<\/div>\n        <div class=\"lm-score-bars\">\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e00<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:85%;background:#c89b3c;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e8c<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:100%;background:#6fae85;\"><\/span><\/span><\/div>\n          <div class=\"lm-score-row\"><span class=\"lm-sname\">\u65b9\u6848\u4e09<\/span><span class=\"lm-sbar\"><span class=\"lm-sfill\" style=\"width:88%;background:#8a6d2f;\"><\/span><\/span><\/div>\n        <\/div><\/div>\n      <div class=\"lm-score-face lm-score-back\"><div class=\"lm-score-dim\">\u5bff\u547d\u8bc4\u5206<\/div>\n        <ul><li>\u5c0a\u777f\u5168\u6548 20\u5e74\u514d\u66f4\u6362<\/li><li>\u71c3\u6c14\u9505\u7089 7-8\u5e74\u5f3a\u5236\u66f4\u6362<\/li><li>\u65b9\u6848\u4e8c \u6c1f\u673a+\u70ed\u6cf5 \u5168\u5468\u671f\u6700\u7701<\/li><\/ul><\/div>\n    <\/div><\/div>\n  <\/div>\n\n  <h4 style=\"margin:18px 0 8px;color:var(--lm-gold2);\">\u5f85\u786e\u8ba4\u4fe1\u606f\uff08P0 \/ P1\uff09<\/h4>\n  <ul class=\"lm-checklist\">\n    <li><span class=\"lm-ck-ico\">\uff1f<\/span><b>\u5916\u673a\u4f4d\u5c3a\u5bf8\uff1a<\/b>\u9700\u73b0\u573a\u590d\u6838224+280\u53cc\u4e3b\u673a\uff08\u6216\u6c34\u5885\u9002\u53cc\u673a\uff09\u5e76\u7f6e\u7a7a\u95f4\uff0c\u786e\u8ba4\u627f\u91cd\u4e0e\u6563\u70ed\u95f4\u8ddd\u3002<\/li>\n    <li><span class=\"lm-ck-ico\">\uff1f<\/span><b>\u5730\u6696\u627e\u5e73\u5c42\u539a\u5ea6\uff1a<\/b>\u9700\u786e\u8ba4\u539f\u7ed3\u6784\u5c42\u9ad8\u4e0e\u56de\u586b\u539a\u5ea6\uff0c\u5f71\u54cd\u5c42\u9ad8\u4e0e\u76d8\u7ba1\u94fa\u8bbe\u5de5\u827a\u3002<\/li>\n  <\/ul>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u6848\u4f8b\u9a8c\u8bc1\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u6848\u4f8b\u5747\u53ef\u5728\u9f99\u8109\u6696\u901a\u5b98\u7f51\u6848\u4f8b\u5e93\uff08<a class=\"lm-case-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\n    <div class=\"lm-more-ico\" style=\"width:40px;height:40px;font-size:18px;\">\u2461<\/div>\n    <div class=\"lm-cc-t\"><b>\u9f99\u8109\u6696\u901a \u00b7 \u6848\u4f8b\u4e2d\u5fc3<\/b><br>200+ \u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\uff0c\u53ef\u67e5\u8be2\u540c\u6237\u578b\u53c2\u8003\u6807\u6746<\/div>\n    <div class=\"lm-cc-go\">\u67e5\u770b\u6848\u4f8b \u2192<\/div>\n  <\/a>\uff09\u67e5\u8be2\u9a8c\u8bc1\u3002\u57ce\u5357\u5b98\u90b8\u9879\u76ee\u7684\u65b9\u6848\u6570\u636e\u4e5f\u5c06\u8131\u654f\u540e\u5165\u5e93\uff0c\u6210\u4e3a\u672a\u6765\u540c\u6237\u578b\u5ba2\u6237\u7684\u53c2\u8003\u6807\u6746\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u552e\u540e\u4fdd\u969c\u4e0e10\u5e74\u80fd\u6e90\u8ba1\u5212<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u8d28\u4fdd\u671f\u9650<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u6574\u673a\uff09<\/td><td>60\u4e2a\u6708<\/td><td>\u8bbe\u5907\u8fdb\u573a\u65e5\u8d77\u7b97\uff0c\u542b6\u4e2a\u6708\u88c5\u4fee\u671f<\/td><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u538b\u7f29\u673a\uff09<\/td><td>60\u4e2a\u6708<\/td><td>\u884c\u4e1a\u5185\u9886\u5148\u8d28\u4fdd\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u4f1f\u661f\u5730\u6696\u7ba1\u9053<\/td><td>50\u5e74<\/td><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd\u4e09\u65b9\u8054\u4fdd<\/td><\/tr>\n    <tr><td>\u9f99\u8109\u5b89\u88c5\u5de5\u7a0b<\/td><td>2\u5e74<\/td><td>\u9690\u853d\u5de5\u7a0b\u7ec8\u8eab\u8d1f\u8d23\u5236<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight-green\" style=\"margin:16px 0;\">\n    <strong>\u57ce\u5357\u5b98\u90b8\u52a0\u5165A\u7ec4\uff08\u8282\u80fd\u65b9\u6848\u7ec4\uff09\uff0c\u4eab\u53d7\u4ee5\u4e0b\u670d\u52a1\uff1a<\/strong><br>\n    1. \u6bcf\u5e74\u91c7\u6696\u5b63\u540e\u4e3b\u52a8\u56de\u8bbf\uff0c\u91c7\u96c6\u80fd\u8017\u6570\u636e\uff1b<br>\n    2. \u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807\u5206\u6790\uff0c\u63d0\u4f9b\u8282\u80fd\u4f18\u5316\u5efa\u8bae\uff1b<br>\n    3. 10\u5e74\u5185\u82e5\u56e0\u8bbe\u8ba1\u6216\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u80fd\u8017\u5f02\u5e38\uff0c\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u8c03\u6574\uff1b<br>\n    4. \u6570\u636e\u8131\u654f\u540e\u533f\u540d\u4f7f\u7528\uff0c\u4fdd\u62a4\u5ba2\u6237\u9690\u79c1\uff1b<br>\n    5. \u552e\u540e\u95ee\u9898\u53cd\u9988\u81f3\u5ba2\u6237\u6863\u6848\uff0c\u53cd\u63a8\u65b9\u6848\u6807\u51c6\u66f4\u65b0\u3002\n  <\/div>\n\n  <table class=\"lm-table\">\n    <tr><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u54cd\u5e94\u6807\u51c6<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u7d27\u6025\u62a5\u4fee<\/td><td>24\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><td>\u7cfb\u7edf\u6545\u969c\u3001\u6f0f\u6c34\u3001\u4e0d\u5236\u51b7\/\u5236\u70ed\u7b49\u7d27\u6025\u95ee\u9898<\/td><\/tr>\n    <tr><td>\u5e38\u89c4\u7ef4\u4fdd<\/td><td>48\u5c0f\u65f6\u5185\u5b89\u6392<\/td><td>\u6ee4\u7f51\u6e05\u6d17\u3001\u7cfb\u7edf\u68c0\u67e5\u3001\u53c2\u6570\u8c03\u8bd5<\/td><\/tr>\n    <tr><td>\u5e74\u5ea6\u56de\u8bbf<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u540e<\/td><td>\u80fd\u8017\u6570\u636e\u91c7\u96c6+\u7cfb\u7edf\u5065\u5eb7\u68c0\u67e5+\u4f18\u5316\u5efa\u8bae<\/td><\/tr>\n    <tr><td>\u8fdc\u7a0b\u8bca\u65ad<\/td><td>\u5373\u65f6<\/td><td>\u901a\u8fc7AI\u96c6\u63a7\u5c4f\u8fdc\u7a0b\u8bfb\u53d6\u8fd0\u884c\u6570\u636e\uff0c\u5feb\u901f\u5b9a\u4f4d\u95ee\u9898<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u53cd\u9988\u673a\u5236\uff1a<\/strong>\u505a\u5b8c\u4e00\u4ef6\u4e8b\uff0c\u5fc5\u987b\u628a\u7ed3\u679c\u586b\u56de\u6765\u3002\u57ce\u5357\u5b98\u90b8\u9879\u76ee\u7684\u6240\u6709\u65bd\u5de5\u6570\u636e\u3001\u9a8c\u6536\u8bb0\u5f55\u3001\u80fd\u8017\u6570\u636e\u5747\u5f55\u5165\u5ba2\u6237\u6210\u529f\u6863\u6848\uff0c\u4f5c\u4e3a\u672a\u6765\u540c\u7c7b\u578b\u9879\u76ee\u7684\u53c2\u8003\u6807\u6746\u3002\u552e\u540e\u95ee\u9898\u53cd\u63a8\u81f3\u65b9\u6848\u6807\u51c6\uff0c\u6301\u7eed\u4f18\u5316\u77e5\u8bc6\u5e93\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== \u4e86\u89e3\u66f4\u591a ===== -->\n<section class=\"lm-section\" id=\"more\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">\uff0b<\/span>\u4e86\u89e3\u66f4\u591a<\/div>\n  <p style=\"color:var(--lm-text2);margin-bottom:8px;font-size:13px;\">\u7b7e\u7ea6\u524d\uff0c\u5efa\u8bae\u60a8\u8fdb\u4e00\u6b65\u4e86\u89e3\u9f99\u8109\u7684\u4ea7\u54c1\u3001\u6848\u4f8b\u4e0e\u670d\u52a1\u4fdd\u969c\uff1a<\/p>\n  <div class=\"lm-more-grid\">\n    <a class=\"lm-more-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\n      <div class=\"lm-more-ico\">\u2460<\/div>\n      <div class=\"lm-more-t\"><b>\u4ea7\u54c1\u8be6\u60c5<\/b><span>\u5c0a\u777f\u5168\u6548 \/ \u6c34\u5885\u9002 \/ \u65b0\u98ce \u5b98\u65b9\u4ea7\u54c1\u9875<\/span><\/div>\n    <\/a>\n    <a class=\"lm-more-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\n      <div class=\"lm-more-ico\">\u2461<\/div>\n      <div class=\"lm-more-t\"><b>\u6848\u4f8b\u4e2d\u5fc3<\/b><span>200+ \u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b \u00b7 \u540c\u6237\u578b\u53c2\u8003<\/span><\/div>\n    <\/a>\n    <a class=\"lm-more-card\" href=\"#s10\">\n      <div class=\"lm-more-ico\">\u2462<\/div>\n      <div class=\"lm-more-t\"><b>\u6388\u6743\u95e8\u5e97\uff08\u53cc\u5e97\uff09<\/b><span>\u5357\u5bcc\u68ee\u5e97 \u00b7 \u5317\u5bcc\u68ee\u5e97 \u5747\u53ef\u9884\u7ea6<\/span><\/div>\n    <\/a>\n    <a class=\"lm-more-card\" href=\"https:\/\/longmai-nt.com\/?page_id=667\" target=\"_blank\">\n      <div class=\"lm-more-ico\">\u2463<\/div>\n      <div class=\"lm-more-t\"><b>\u767d\u76ae\u4e66 \/ \u907f\u5751\u6307\u5357<\/b><span>\u5730\u6696\u6210\u672c\u5206\u6790 \u00b7 \u9009\u578b\u907f\u5751<\/span><\/div>\n    <\/a>\n  <\/div>\n<\/section>\n\n<!-- ===== \u5e38\u89c1\u95ee\u9898 FAQ ===== -->\n<section class=\"lm-section\" id=\"faq\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">\uff1f<\/span>\u5e38\u89c1\u95ee\u9898<\/div>\n  <div class=\"lm-faq-list\">\n    <div class=\"lm-faq-item\"><div class=\"lm-faq-q\">\u57ce\u5357\u5b98\u90b8\u4e09\u5957\u65b9\u6848\u6700\u5927\u7684\u533a\u522b\u662f\u4ec0\u4e48\uff1f<\/div>\n      <div class=\"lm-faq-a\">\u6838\u5fc3\u533a\u522b\u5728\u51b7\u70ed\u6e90\u5f62\u6001\u4e0e\u5730\u4e0b\u5ba4\u9664\u6e7f\u8def\u5f84\uff1a\u65b9\u6848\u4e00\u6c34\u5885\u9002FX\u6c34\u673a\u4e8c\u8054\u4f9b\uff08\u53cc\u673a\u5e76\u8054\u3001\u4e00\u7528\u4e00\u5907\u3001\u51fa\u98ce\u67d4\u548c\u4f46\u9700\u914d\u5929\u51c0\u9664\u6e7f\u65b0\u98ce\uff09\uff1b\u65b9\u6848\u4e8c\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff08\u6c1f\u7cfb\u7edf\u7a33\u5b9a\u3001\u81ea\u6e05\u6d01\u3001\u6e29\u6e7f\u53cc\u63a7\u7cbe\u51c6\u9664\u6e7f\u3001\u6c34\u6a21\u5757\u505a\u70ed\u6cf5\u5730\u6696\uff09\uff1b\u65b9\u6848\u4e09\u5c0a\u777f\u5168\u6548\u4e2d\u592e\u7a7a\u8c03\uff08\u914d\u7f6e\u540c\u65b9\u6848\u4e8c\u4f46\u65e0\u6c34\u6a21\u5757\uff0c\u5730\u6696\u5168\u7531\u9505\u7089\u627f\u62c5\uff09\u3002<\/div><\/div>\n    <div class=\"lm-faq-item\"><div class=\"lm-faq-q\">\u5730\u4e0b\u5ba4\uff08\u8d1f\u4e00\u697c\u8d1f\u4e8c\u697c\uff09\u9664\u6e7f\u901a\u98ce\u600e\u4e48\u89e3\u51b3\uff1f<\/div>\n      <div class=\"lm-faq-a\">\u65b9\u6848\u4e00\u91c7\u7528\u65e5\u7acb\u5929\u51c0\u9664\u6e7f\u65b0\u98ce350\uff08\u9664\u6e7f+\u65b0\u98ce\u4e00\u4f53\uff09\uff1b\u65b9\u6848\u4e8c\/\u4e09\u91c7\u7528\u5c0a\u777f\u4e09\u7ba1\u5236\u5185\u673a\u5185\u7f6e\u6e29\u6e7f\u53cc\u63a7\u72ec\u7acb\u9664\u6e7f\uff08\u6548\u679c\u4f18\u4e8e\u72ec\u7acb\u9664\u6e7f\u65b0\u98ce\uff09\uff0c\u5730\u4e0b\u5ba4\u4ec5\u9700\u65e5\u7acb\u4e91\u51c0\u666e\u901a\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u8d1f\u8d23\u901a\u98ce\u6362\u6c14\u3002\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\u4e0e\u5730\u4e0b\u5ba4\u9632\u6f6e\uff0c\u5c0a\u777f\u5185\u7f6e\u9664\u6e7f\u66f4\u7cbe\u51c6\u3002<\/div><\/div>\n    <div class=\"lm-faq-item\"><div class=\"lm-faq-q\">\u5927\u5b85\uff08483\u33a1\u30014-5\u4eba\uff09\u5982\u4f55\u517c\u987e\u8282\u80fd\u4e0e\u9884\u7b97\uff1f<\/div>\n      <div class=\"lm-faq-a\">\u65b9\u6848\u4e00\u6c34\u673a\u53cc\u673a\u5e76\u8054\uff0c\u4eba\u5c11\u65f6\u5355\u53f0\u4f4e\u8d1f\u8377\u3001\u4eba\u591a\u65f6\u53cc\u673a\u540c\u5f00\u4e14\u4e00\u7528\u4e00\u5907\uff1b\u65b9\u6848\u4e8c\u6c34\u6a21\u5757\u4e8c\u8054\u4f9b\u8ba9\u70ed\u6cf5\u53c2\u4e0e\u5730\u6696\uff08COP\u22653\uff0c\u957f\u671f\u7701\u6c14\uff09\u3002\u603b\u6295\u5165\uff1a\u65b9\u6848\u4e8c270,713\u5143\u6700\u4f4e\u3001\u65b9\u6848\u4e00274,748\u5143\u3001\u65b9\u6848\u4e09280,006\u5143\u6700\u9ad8\u3002<\/div><\/div>\n    <div class=\"lm-faq-item\"><div class=\"lm-faq-q\">\u54ea\u5957\u65b9\u6848\u7cfb\u7edf\u6700\u7a33\u5b9a\u3001\u7ef4\u62a4\u6700\u7b80\u5355\uff1f<\/div>\n      <div class=\"lm-faq-a\">\u5c0a\u777f\u5168\u6548\uff08\u65b9\u6848\u4e8c\/\u4e09\uff09\u4e3a\u6c1f\u7cfb\u7edf\uff0c\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\u3001\u65e0\u6f0f\u6c34\u98ce\u9669\uff0c\u5185\u673a\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc+PE\u51c0\u5316\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\uff1b\u6c34\u5885\u9002\uff08\u65b9\u6848\u4e00\uff09\u4e3a\u5168\u6c34\u7cfb\u7edf\uff0c\u63a5\u5934\u591a\u3001\u9700\u5b9a\u671f\u6e05\u6d17\u8fc7\u6ee4\u5668\u4e0e\u7ba1\u8def\uff0c\u7ef4\u62a4\u9700\u6c42\u76f8\u5bf9\u8f83\u9ad8\u3002<\/div><\/div>\n    <div class=\"lm-faq-item\"><div class=\"lm-faq-q\">\u5927\u5b85\uff08483\u33a1\u00b76\u5c42\uff09\u4e3b\u673a\u6545\u969c\u600e\u4e48\u529e\uff1f\u540e\u671f\u7ef4\u62a4\u9891\u7387\u9ad8\u5417\uff1f<\/div>\n      <div class=\"lm-faq-a\">\u65b9\u6848\u4e00\u6c34\u5885\u9002\u53cc\u673a\u5e76\u8054\u4e00\u7528\u4e00\u5907\uff0c\u5355\u53f0\u6545\u969c\u53e6\u4e00\u53f0\u53ef\u9876\u4e0a\uff1b\u65b9\u6848\u4e8c\/\u4e09\u6c1f\u7cfb\u7edf\u5206\u533a\uff08224\u8d1f\u62c5\u8d1f2-1F\u3001280\u8d1f\u62c52-4F\uff09\uff0c\u5355\u53f0\u6545\u969c\u4ec5\u5f71\u54cd\u534a\u5b85\uff0c\u4e14\u6c1f\u7cfb\u7edf\u65e0\u6f0f\u6c34\u98ce\u9669\u3001\u5185\u673a\u81ea\u6e05\u6d01\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\uff0c\u7ef4\u62a4\u9891\u7387\u4f4e\u3002\u9f99\u8109\u53e6\u63d0\u4f9b10\u5e74\u80fd\u6e90\u4fdd\u969c\u4e0e24\u5c0f\u65f6\u7d27\u6025\u54cd\u5e94\u3002<\/div><\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u9644\u5f55\u00b7\u54c1\u724c\u6388\u6743 ===== -->\n<section class=\"lm-section\" id=\"sa\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">\u9644<\/span>\u54c1\u724c\u6388\u6743<\/div>\n  <p style=\"color:var(--lm-text2);margin-bottom:16px;\">\u9f99\u8109\u6696\u901a\u6301\u6709\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u8d44\u8d28\uff0c\u4ee5\u4e0b\u4e3a\u76f8\u5173\u6388\u6743\u8bc1\u4e66\u5b9e\u62cd\uff1a<\/p>\n  <div class=\"lm-img-row\">\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\u8bc1\u4e66\uff082026\uff09\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\u8bc1\u4e66\uff082026\uff09\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\u8bc1\u4e66\uff082024\uff09\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082024\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u670d\u52a1\u6388\u6743\u8bc1\u4e66\uff082026\uff09\" loading=\"lazy\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u7279\u9080\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u6c34\u7cfb\u7edf\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u6c34\u7cfb\u7edf\u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u8054\u7cfb\u6211\u4eec ===== -->\n<section class=\"lm-section lm-contact-footer\" id=\"s10\">\n  <div class=\"lm-cf-header\">\n    <div class=\"lm-cf-title\"><span class=\"lm-phone-icon\">\u260e<\/span>\u8054\u7cfb\u6211\u4eec<\/div>\n    <div class=\"lm-cf-sub\">\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u91cf\u623f\u5b9a\u5236\u7cfb\u7edf\u65b9\u6848 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5<\/div>\n  <\/div>\n\n  <div class=\"lm-cf-contacts\">\n    <a href=\"tel:028-86131795\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u5357\u5bcc\u68ee\u5e97<\/span><span class=\"lm-phone\">028-86131795<\/span><\/div>\n    <\/a>\n    <a href=\"tel:028-65272586\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u5317\u5bcc\u68ee\u5e97<\/span><span class=\"lm-phone\">028-65272586<\/span><\/div>\n    <\/a>\n    <a href=\"tel:028-61649321\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u552e\u540e\u4e13\u7ebf<\/span><span class=\"lm-phone\">028-61649321<\/span><\/div>\n    <\/a>\n    <a href=\"tel:13008113409\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u672c\u6848\u987e\u95ee\u4f59\u6653\u73b2<\/span><span class=\"lm-phone\">130-0811-3409<\/span><\/div>\n    <\/a>\n  <\/div>\n\n  <div class=\"lm-cf-services\">\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u4e0a\u95e8\u5b9e\u5730\u52d8\u6d4b<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u4e13\u5c5e\u6237\u578b\u65b9\u6848\u62a5\u4ef7<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>36\u9879\u65bd\u5de5\u8282\u70b9\u9a8c\u6536<\/div>\n  <\/div>\n\n  <div class=\"lm-cf-stores\">\n    <div class=\"lm-cf-store\">\n      <div class=\"lm-store-label\"><span class=\"lm-pin\">\u25c6<\/span>\u5357\u5bcc\u68ee\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u5e97\">\n      <div class=\"lm-store-addr\"><span class=\"lm-pin\">\u25c6<\/span>\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/div>\n    <\/div>\n    <div class=\"lm-cf-store\">\n      <div class=\"lm-store-label\"><span class=\"lm-pin\">\u25c6<\/span>\u5317\u5bcc\u68ee\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u5e97\">\n      <div class=\"lm-store-addr\"><span class=\"lm-pin\">\u25c6<\/span>\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u99865\u697cA5135\u53f7<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-cf-service-area\">\n    <span class=\"lm-label\">\u670d\u52a1\u8986\u76d6\u533a\u53bf\uff1a<\/span>\u65b0\u90fd \u00b7 \u53cc\u6d41 \u00b7 \u90eb\u90fd \u00b7 \u90eb\u57ce \u00b7 \u6b66\u4faf \u00b7 \u6210\u534e \u00b7 \u5f6d\u5dde \u00b7 \u9f99\u6cc9 \u00b7 \u6e29\u6c5f \u7b49\u5168\u5883\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u65bd\u5de5\n  <\/div>\n\n  <div class=\"lm-cf-cta\">\n    <a href=\"tel:13008113409\" class=\"lm-btn\">\u514d\u8d39\u9884\u7ea6\u52d8\u6d4b \u2192<\/a>\n  <\/div>\n\n  <div class=\"lm-cf-footer-note\">* \u5177\u4f53\u9700\u7528\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u5dee\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/div>\n<\/section>\n\n<\/div>\n\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/echarts@5.5.0\/dist\/echarts.min.js\"><\/script>\n<script>\n\/\/ ===== \u5bfc\u822a\u9ad8\u4eae =====\nconst lmTocItems = document.querySelectorAll('.lm-toc-item');\nconst lmSections = document.querySelectorAll('.lm-section');\nfunction lmUpdateActive() {\n  let current = 0;\n  const scrollY = window.scrollY + 80;\n  lmSections.forEach((sec, i) => {\n    const top = sec.offsetTop;\n    const bottom = top + sec.offsetHeight;\n    if (scrollY >= top && scrollY < bottom) current = i;\n  });\n  lmTocItems.forEach((item, i) => item.classList.toggle('lm-active', i === current));\n}\nwindow.addEventListener('scroll', lmUpdateActive);\nlmUpdateActive();\n\n\/\/ ===== Tabs\uff08\u7cfb\u7edf\u5bf9\u6bd4\uff09 =====\ndocument.querySelectorAll('.lm-tab-btn').forEach(btn => {\n  btn.addEventListener('click', () => {\n    const tab = btn.dataset.tab;\n    document.querySelectorAll('.lm-tab-btn').forEach(b => b.classList.remove('lm-active'));\n    document.querySelectorAll('.lm-tab-panel').forEach(p => p.classList.remove('lm-active'));\n    btn.classList.add('lm-active');\n    document.getElementById(tab).classList.add('lm-active');\n  });\n});\n\n\/\/ ===== \u624b\u98ce\u7434\uff08\u8f85\u6750\u6e05\u5355\uff09 =====\ndocument.querySelectorAll('.lm-acc-head').forEach(head => {\n  head.addEventListener('click', () => {\n    head.parentElement.classList.toggle('lm-open');\n  });\n});\n\n\/\/ ===== \u8f6e\u64ad\uff08\u7cbe\u5de5\u516d\u6b65\u6cd5\uff09 =====\nconst lmCarTrack = document.querySelector('#lmCraftCarousel .lm-carousel-track');\nconst lmCarSlides = document.querySelectorAll('#lmCraftCarousel .lm-slide');\nconst lmCarDots = document.getElementById('lmCarDots');\nlet lmCarCur = 0;\nconst lmCarCnt = lmCarSlides.length;\nlmCarSlides.forEach((_, i) => {\n  const d = document.createElement('span');\n  d.className = 'lm-dot' + (i === 0 ? ' lm-active' : '');\n  d.addEventListener('click', () => lmCarGo(i));\n  lmCarDots.appendChild(d);\n});\nfunction lmCarGo(n) {\n  lmCarCur = (n + lmCarCnt) % lmCarCnt;\n  lmCarTrack.style.transform = 'translateX(-' + (lmCarCur * 100) + '%)';\n  document.querySelectorAll('#lmCarDots .lm-dot').forEach((d, i) => d.classList.toggle('lm-active', i === lmCarCur));\n}\n\n\/\/ ===== ECharts \u4e09\u65b9\u6848\u5bf9\u6bd4\uff08\u5806\u53e0\uff09 =====\nif (window.echarts) {\n  const planChart = echarts.init(document.getElementById('lmPlanChart'));\n  planChart.setOption({\n    backgroundColor: 'transparent',\n    tooltip: { trigger: 'axis', axisPointer: { type: 'shadow' }, formatter: function(p){\n      let s = p[0].axisValue + '<br\/>';\n      let total = 0;\n      p.forEach(function(it){ s += it.marker + it.seriesName + '\uff1a\u00a5' + it.value.toLocaleString() + '<br\/>'; total += it.value; });\n      s += '<b>\u5408\u8ba1\uff1a\u00a5' + total.toLocaleString() + '<\/b>';\n      return s;\n    } },\n    legend: { bottom: 0, textStyle: { color: '#5a4d38' } },\n    grid: { left: 70, right: 30, top: 30, bottom: 50 },\n    xAxis: { type: 'category', data: ['\u65b9\u6848\u4e00\\n\u6c34\u5885\u9002\u4e8c\u8054\u4f9b', '\u65b9\u6848\u4e8c\\n\u5c0a\u777f+\u6c34\u6a21\u5757', '\u65b9\u6848\u4e09\\n\u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03'], axisLabel: { color: '#3a3326', fontSize: 12, lineHeight: 16 } },\n    yAxis: { type: 'value', name: '\u5143', axisLabel: { color: '#5a4d38', formatter: function(v){ return (v\/10000)+'\u4e07'; } }, splitLine: { lineStyle: { color: '#e6dfcd' } } },\n    series: [\n      { name: '\u7a7a\u8c03\u4e3b\u673a+\u5185\u673a', type: 'bar', stack: 't', itemStyle: { color: '#c89b3c' }, data: [145032, 153297, 134196] },\n      { name: '\u65b0\u98ce\u7cfb\u7edf', type: 'bar', stack: 't', itemStyle: { color: '#e0b552' }, data: [43152, 30852, 30852] },\n      { name: '\u5730\u6696\u7cfb\u7edf', type: 'bar', stack: 't', itemStyle: { color: '#8a6d2f' }, data: [86564, 86564, 114958] },\n      { name: '\u4e8c\u8054\u4f9b\/\u9664\u6e7f\u7ec4\u4ef6', type: 'bar', stack: 't', itemStyle: { color: '#b8860b' }, data: [0, 19101, 0] }\n    ]\n  });\n  \/\/ 20\u5e74\u5168\u5468\u671f\u603b\u6295\u5165\u53cd\u8f6c\u5361\u7247\n  const lm20Years = [];\n  for (let i = 0; i <= 20; i++) lm20Years.push(i === 0 ? '\u521d\u6295' : ('\u7b2c' + i + '\u5e74'));\n  const lm20d1 = [], lm20d2 = [], lm20d3 = [];\n  for (let i = 0; i <= 20; i++) {\n    lm20d1.push(274748 + 11990 * i);\n    lm20d2.push(270713 + 11190 * i);\n    lm20d3.push(280006 + 14239 * i);\n  }\n  const chart20 = echarts.init(document.getElementById('lm20Chart'));\n  chart20.setOption({\n    backgroundColor: 'transparent',\n    tooltip: { trigger: 'axis', formatter: function(p) {\n      let s = p[0].axisValue + '<br\/>';\n      p.forEach(function(it){ s += it.marker + it.seriesName + '\uff1a\u00a5' + Math.round(it.value).toLocaleString() + '<br\/>'; });\n      return s;\n    } },\n    legend: { bottom: 0, textStyle: { color: '#5a4d38' } },\n    grid: { left: 78, right: 25, top: 25, bottom: 45 },\n    xAxis: { type: 'category', data: lm20Years, axisLabel: { color: '#3a3326', fontSize: 11, interval: 2 } },\n    yAxis: { type: 'value', name: '\u5143', axisLabel: { color: '#5a4d38', formatter: function(v){ return (v\/10000)+'\u4e07'; } }, splitLine: { lineStyle: { color: '#e6dfcd' } } },\n    series: [\n      { name: '\u65b9\u6848\u4e00 \u6c34\u5885\u9002', type: 'line', smooth: true, data: lm20d1, itemStyle: { color: '#c89b3c' }, lineStyle: { width: 2 } },\n      { name: '\u65b9\u6848\u4e8c \u5c0a\u777f+\u6c34\u6a21\u5757', type: 'line', smooth: true, data: lm20d2, itemStyle: { color: '#6fae85' }, lineStyle: { width: 3 } },\n      { name: '\u65b9\u6848\u4e09 \u5c0a\u777f\u4e2d\u592e\u7a7a\u8c03', type: 'line', smooth: true, data: lm20d3, itemStyle: { color: '#8a6d2f' }, lineStyle: { width: 2 } }\n    ]\n  });\n\n  window.addEventListener('resize', () => { planChart.resize(); chart20.resize(); });\n}\n\/\/ ===== FAQ \u624b\u98ce\u7434\uff08\u5e38\u89c1\u95ee\u9898\uff09 =====\ndocument.querySelectorAll('.lm-faq-q').forEach(function(q){\n  q.addEventListener('click', function(){ q.parentElement.classList.toggle('lm-open'); });\n});\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\u5c01\u9762 S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 S2\u00b7\u65b9\u6848\u8bca\u65ad [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-7995","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=7995\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5c01\u9762 S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 S2\u00b7\u65b9\u6848\u8bca\u65ad [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=7995\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-26T05:58:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"15 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995\",\"name\":\"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\",\"datePublished\":\"2026-07-24T07:34:41+00:00\",\"dateModified\":\"2026-07-26T05:58:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=7995#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=7995","og_locale":"zh_CN","og_type":"article","og_title":"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5c01\u9762 S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 S2\u00b7\u65b9\u6848\u8bca\u65ad [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=7995","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-26T05:58:55+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"15 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=7995","url":"https:\/\/longmai-nt.com\/?page_id=7995","name":"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=7995#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=7995#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","datePublished":"2026-07-24T07:34:41+00:00","dateModified":"2026-07-26T05:58:55+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=7995#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=7995"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=7995#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=7995#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u57ce\u5357\u5b98\u90b8 \u00b7 \u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7995","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7995"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7995\/revisions"}],"predecessor-version":[{"id":8479,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/7995\/revisions\/8479"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}