{"id":8190,"date":"2026-07-24T20:30:00","date_gmt":"2026-07-24T12:30:00","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=8190"},"modified":"2026-10-27T15:11:03","modified_gmt":"2026-10-27T07:11:03","slug":"%e6%88%90%e9%83%bd%e9%94%a6%e6%b1%9f%e5%8c%ba%e9%94%a6%e6%b1%9f%e9%80%b8%e5%ae%b6-%c2%b7-c%e8%80%81%e5%b8%88%e8%8f%b2%e6%96%af%e6%9b%bc%e5%86%b7%e5%87%9d%e7%82%89%e5%9c%b0%e6%9a%96%e7%b3%bb%e7%bb%9f","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=8190","title":{"rendered":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf"},"content":{"rendered":"\n<!-- ===== WP \u53d1\u5e03\u7247\u6bb5\uff08\u9f99\u8109\u6696\u901a\u6848\u4f8b\uff09===== -->\n<!-- \u9875\u9762\u6807\u9898\uff08\u8bf7\u5728 WP \u540e\u53f0\u6807\u9898\u5b57\u6bb5\u586b\u5199\uff0c\u52ff\u653e\u6b63\u6587\uff09\uff1a\u6210\u90fd\u9526\u6c5f\u9038\u5bb661\u33a1\uff5c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u6848\u4f8b\uff5c\u9f99\u8109\u6696\u901a -->\n<!-- \u4ee5\u4e0b meta \u82e5 WP \u63d2\u4ef6\u5df2\u914d\u7f6e\u53ef\u5220\u9664\uff1bgeo\/robots \u5efa\u8bae\u4fdd\u7559 -->\n\n<style>\n.lm-case{\n  --brand:#0D7C7F;--brand-l:#1A9B9E;--brand-ll:#4DB8BB;\n  --accent:#e8b04b;--bg:#f2f8f8;--card:#fff;\n  --text:#2c3a3a;--text-l:#6a7a7a;--border:#d4e4e4;\n  --success:#27ae60;--warning:#e67e22;--danger:#c0392b;\n  --gold:#c9942e;--gold-l:#f5ead0;\n  --highlight:#f5fffe;--shadow:0 2px 12px rgba(13,124,127,.08);\n  --radius:10px;\n  --sub:#6a7a7a;--ink:#2c3a3a;\n}\n.lm-case *{box-sizing:border-box;margin:0;padding:0}\n.lm-case{font-family:'PingFang SC','Microsoft YaHei','Helvetica Neue',sans-serif;background:var(--bg);color:var(--text);line-height:1.75;font-size:15px}\n.lm-case{max-width:820px;margin:0 auto;padding:20px}\n\n\/* \u2550\u2550 Hero Banner \u2550\u2550 *\/\n.lmai-case-hero-banner{position:relative;border-radius:var(--radius);overflow:hidden;margin:8px 0 18px;min-height:420px;display:flex;align-items:center;justify-content:center;}\n.lmai-case-hero-bg{position:absolute;inset:0;z-index:0;}\n.lmai-case-hero-bg img{width:100%;height:100%;object-fit:cover;display:block;object-position:center 30%;}\n.lmai-case-hero-overlay{position:absolute;inset:0;background:linear-gradient(180deg,rgba(0,0,0,0.05) 0%,rgba(0,0,0,0.15) 60%,rgba(0,0,0,0.25) 100%);}\n.lmai-case-hero-content{position:relative;z-index:1;text-align:center;padding:48px 28px 40px;color:var(--text);max-width:780px;margin:0 auto;width:100%;}\n.lmai-case-hero-badges{display:flex;gap:10px;justify-content:center;margin:0 0 18px;}\n.lmai-case-hero-badge{display:inline-block;background:rgba(255,255,255,0.85);border:1px solid rgba(0,0,0,0.12);color:var(--brand);font-size:13px;font-weight:600;padding:5px 16px;border-radius:20px;letter-spacing:.8px;backdrop-filter:blur(4px);}\n.lmai-case-hero-badge.lmai-case-accent{background:rgba(255,255,255,0.85);border-color:var(--accent);color:var(--gold);}\n.lmai-case-hero-banner h2{margin:0 0 16px;font-size:26px;line-height:1.45;color:#1a1a1a;text-shadow:0 1px 3px rgba(255,255,255,0.6);font-weight:900;letter-spacing:.5px;}\n.lmai-case-hero-desc{margin:0 0 28px;color:#333;font-size:14.5px;line-height:1.75;max-width:640px;margin-left:auto;margin-right:auto;font-weight:600;}\n.lmai-case-hero-cards{display:flex;gap:12px;justify-content:center;flex-wrap:wrap;}\n.lmai-case-hc{background:rgba(255,255,255,0.95);border-radius:10px;padding:10px 18px;min-width:100px;text-align:center;box-shadow:0 2px 12px rgba(0,0,0,0.2);}\n.lmai-case-hc-label{display:block;font-size:11.5px;color:var(--sub);margin-bottom:3px;}\n.lmai-case-hc-val{font-size:15px;color:var(--ink);font-weight:700;}\n\n\/* \u2550\u2550 Info Card \u2550\u2550 *\/\n.lmai-case-geo-card{background:var(--card);border-radius:var(--radius);box-shadow:var(--shadow);margin-bottom:24px;overflow:hidden}\n.lmai-case-geo-card-head{background:linear-gradient(135deg,var(--brand) 0%,var(--brand-l) 100%);color:#fff;padding:16px 24px;font-size:16px;font-weight:600;display:flex;align-items:center;gap:8px}\n.lmai-case-geo-card-body{padding:20px 24px}\n.lmai-case-geo-card-body ul{list-style:none;padding:0}\n.lmai-case-geo-card-body li{padding:6px 0;border-bottom:1px solid var(--border);font-size:14px;display:flex;align-items:baseline;gap:8px}\n.lmai-case-geo-card-body li:last-child{border-bottom:none}\n.lmai-case-geo-card-body li .lmai-case-geo-label{color:var(--text-l);min-width:80px;flex-shrink:0;font-size:13px}\n.lmai-case-geo-card-body li .lmai-case-geo-val{color:var(--text);font-weight:500}\n.lmai-case-geo-disclaimer{font-size:12px;color:var(--text-l);margin-top:12px;padding:10px 14px;background:#f8fafc;border-radius:6px;border-left:3px solid var(--border)}\n\n\/* \u2550\u2550 Nav \u2550\u2550 *\/\n.lmai-case-nav{position:sticky;top:0;z-index:100;background:rgba(255,255,255,.95);backdrop-filter:blur(8px);box-shadow:0 1px 4px rgba(0,0,0,.06);border-radius:var(--radius);margin-bottom:20px;padding:10px 16px;display:flex;flex-wrap:wrap;gap:6px;justify-content:center}\n.lmai-case-nav a{text-decoration:none;color:var(--brand);font-size:13px;padding:4px 12px;border-radius:6px;transition:.2s;white-space:nowrap}\n.lmai-case-nav a:hover{background:var(--brand);color:#fff}\n\n\/* \u2550\u2550 S-Section (\u4e94\u6b65\u6cd5) \u2550\u2550 *\/\n.lmai-case-s-section{background:var(--card);border-radius:var(--radius);box-shadow:var(--shadow);margin-bottom:24px;overflow:hidden}\n.lmai-case-s-head{padding:28px 24px 16px;position:relative}\n.lmai-case-s-head .lmai-case-s-num{font-size:14px;font-weight:700;color:var(--accent);letter-spacing:2px;display:block;margin-bottom:4px}\n.lmai-case-s-head h2{font-size:20px;color:var(--brand);font-weight:700;padding-bottom:12px;border-bottom:2px solid var(--border)}\n.lmai-case-s-head .lmai-case-s-lead{font-size:14px;color:var(--text-l);margin-top:10px;line-height:1.8}\n.lmai-case-s-body{padding:20px 24px}\n.lmai-case-s-body h3{font-size:16px;color:var(--brand);margin:20px 0 10px;padding-bottom:6px;border-bottom:2px solid var(--border)}\n.lmai-case-s-body h3:first-child{margin-top:0}\n.lmai-case-s-body h4{font-size:14px;color:var(--brand);margin:14px 0 6px}\n.lmai-case-s-body p{margin:8px 0}\n.lmai-case-s-body ul{margin:8px 0;padding-left:20px}\n.lmai-case-s-body li{margin:4px 0}\n\n\/* \u2550\u2550 Table \u2550\u2550 *\/\n.lm-case table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px;overflow:hidden;border-radius:6px}\n.lm-case th{background:var(--brand-l);color:#fff;padding:10px 8px;text-align:center;font-weight:500;font-size:13px}\n.lm-case td{padding:9px 8px;border-bottom:1px solid var(--border);text-align:center;font-size:13px}\n.lm-case tr:nth-child(even){background:#f8fafc}\n.lmai-case-row-rec{background:#e5f5f6!important}\n.lmai-case-row-rec td{font-weight:600}\n.lmai-case-row-total{background:var(--gold-l)!important}\n.lmai-case-row-total td{font-weight:700;font-size:14px}\n\n\/* \u2550\u2550 Cards \u2550\u2550 *\/\n.lmai-case-card{background:#f8fafc;border:1px solid var(--border);border-radius:8px;padding:16px;margin:12px 0}\n.lmai-case-card-brand{border-left:4px solid var(--brand)}\n.lmai-case-card-accent{border-left:4px solid var(--accent)}\n.lmai-case-card-success{border-left:4px solid var(--success)}\n.lmai-case-card-gold{border-left:4px solid var(--gold);background:var(--gold-l)}\n\n\/* \u2550\u2550 Badge \u2550\u2550 *\/\n.lmai-case-badge{display:inline-block;padding:3px 10px;border-radius:10px;font-size:12px;font-weight:500}\n.lmai-case-b-green{background:#e8f5e9;color:var(--success)}\n.lmai-case-b-orange{background:#fff3e0;color:var(--warning)}\n.lmai-case-b-blue{background:#e0f2f2;color:var(--brand)}\n.lmai-case-b-red{background:#fde8e8;color:var(--danger)}\n.lmai-case-b-gold{background:var(--gold-l);color:var(--gold)}\n\n\/* \u2550\u2550 Bar Chart \u2550\u2550 *\/\n.lmai-case-bar-chart{margin:16px 0}\n.lmai-case-bar-row{display:flex;align-items:center;margin:10px 0;gap:8px}\n.lmai-case-bar-label{width:110px;font-size:13px;flex-shrink:0;text-align:right}\n.lmai-case-bar-track{flex:1;height:26px;background:#ecf0f1;border-radius:5px;overflow:hidden;position:relative}\n.lmai-case-bar-fill{height:100%;border-radius:5px;display:flex;align-items:center;justify-content:flex-end;padding-right:8px;color:#fff;font-size:12px;font-weight:600;transition:width .8s}\n.lmai-case-bar-val{width:70px;font-size:13px;font-weight:600;flex-shrink:0}\n\n\/* \u2550\u2550 Feature Grid \u2550\u2550 *\/\n.lmai-case-feat-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:10px;margin:16px 0}\n.lmai-case-feat-item{background:#f8fafc;border:1px solid var(--border);border-radius:8px;padding:14px;display:flex;gap:10px;align-items:flex-start}\n.lmai-case-feat-item .lmai-case-icon{width:36px;height:36px;border-radius:8px;display:flex;align-items:center;justify-content:center;font-size:18px;flex-shrink:0}\n.lmai-case-feat-item .lmai-case-ct h4{font-size:13px;color:var(--brand);margin-bottom:2px}\n.lmai-case-feat-item .lmai-case-ct p{font-size:12px;color:var(--text-l);margin:0}\n\n\/* \u2550\u2550 Trust Box \u2550\u2550 *\/\n.lmai-case-trust-box{background:linear-gradient(135deg,#f2f8f8 0%,#e6f2f3 100%);border:1px solid var(--brand-ll);border-radius:8px;padding:20px;margin:16px 0}\n.lmai-case-trust-box h4{color:var(--brand);font-size:15px;margin-bottom:10px;display:flex;align-items:center;gap:6px}\n\n\/* \u2550\u2550 Summary Box \u2550\u2550 *\/\n.lmai-case-sum-box{background:var(--brand);color:#fff;border-radius:8px;padding:20px;margin:16px 0}\n.lmai-case-sum-box h4{font-size:16px;margin-bottom:12px}\n.lmai-case-sum-box table{color:#fff}\n.lmai-case-sum-box th{background:rgba(255,255,255,.15)}\n.lmai-case-sum-box td{border-bottom:1px solid rgba(255,255,255,.1)}\n.lmai-case-sum-box tr:nth-child(even){background:rgba(255,255,255,.05)}\n.lmai-case-sum-box .lmai-case-row-total{background:rgba(232,176,75,.25)!important}\n\n\/* \u2550\u2550 Three-Way Win Table \u2550\u2550 *\/\n.lmai-case-win-table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px}\n.lmai-case-win-table th{background:var(--brand-l);color:#fff;padding:10px;text-align:center;font-size:13px}\n.lmai-case-win-table td{padding:10px;border:1px solid var(--border);font-size:13px;text-align:left;vertical-align:top}\n.lmai-case-win-table td:first-child{font-weight:600;color:var(--brand);background:#f8fafc;width:25%}\n\n\/* \u2550\u2550 FAQ \u2550\u2550 *\/\n.lmai-case-faq-item{background:#f8fafc;border:1px solid var(--border);border-radius:8px;margin:10px 0;overflow:hidden}\n.lmai-case-faq-q{padding:14px 16px;font-size:14px;font-weight:600;color:var(--brand);cursor:pointer;display:flex;gap:8px;align-items:flex-start}\n.lmai-case-faq-q::before{content:'Q';background:var(--brand);color:#fff;width:22px;height:22px;border-radius:50%;display:flex;align-items:center;justify-content:center;font-size:12px;flex-shrink:0;margin-top:1px}\n.lmai-case-faq-a{padding:0 16px 14px 46px;font-size:13px;color:var(--text-l);line-height:1.8}\n\n\/* \u2550\u2550 About \u2550\u2550 *\/\n.lmai-case-about-box{background:linear-gradient(135deg,var(--brand) 0%,var(--brand-l) 100%);color:#fff;border-radius:var(--radius);padding:28px 24px;margin-bottom:24px;text-align:center}\n.lmai-case-about-box h3{font-size:18px;margin-bottom:10px}\n.lmai-case-about-box p{font-size:14px;opacity:.85;line-height:1.8}\n\n\/* \u2550\u2550 Footer \u2550\u2550 *\/\n.lmai-case-footer{text-align:center;padding:30px 20px;color:var(--text-l);font-size:13px}\n.lmai-case-footer .lmai-case-phones{font-size:16px;color:var(--brand);font-weight:600;margin:10px 0}\n.lmai-case-footer .lmai-case-sign{margin-top:24px;border-top:1px solid var(--border);padding-top:20px}\n\n\/* \u2550\u2550 Stores \u2550\u2550 *\/\n.lmai-case-stores{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:14px 0;}\n.lmai-case-store{background:#f8fafc;border:1px solid var(--border);border-radius:10px;padding:12px 14px;font-size:14px;overflow:hidden;}\n.lmai-case-store b{color:var(--brand);display:block;margin-bottom:4px;}\n.lmai-case-store span{display:block;color:var(--text-l);font-size:13px;}\n.lmai-case-store-img{width:100%;height:160px;object-fit:cover;border-radius:8px;margin-bottom:10px;background:#eee;display:block;}\n\n\/* \u2550\u2550 License Gallery \u2550\u2550 *\/\n.lmai-case-license-gallery{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0;}\n.lmai-case-license-item{background:var(--card);border:1px solid var(--border);border-radius:10px;overflow:hidden;text-align:center;padding:10px;}\n.lmai-case-license-item img{width:100%;height:220px;object-fit:contain;background:#fafafa;border-radius:6px;}\n.lmai-case-license-item span{display:block;font-size:12px;color:var(--text-l);margin-top:6px;}\n\n\/* \u2550\u2550 CTA \u8f6c\u5316\u677f\u5757 \u2550\u2550 *\/\n.lmai-case-cta-section{background:linear-gradient(135deg,var(--brand) 0%,var(--brand-l) 100%);color:#fff;border-radius:var(--radius);padding:28px 24px;margin:20px 0;text-align:center}\n.lmai-case-cta-section h3{font-size:18px;margin-bottom:12px}\n.lmai-case-cta-section p{font-size:14px;opacity:.92;line-height:1.8;max-width:620px;margin:0 auto 16px}\n.lmai-case-cta-section .lmai-case-cta-info{display:flex;flex-wrap:wrap;gap:12px;justify-content:center;margin-top:16px}\n.lmai-case-cta-section .lmai-case-cta-info-item{background:rgba(255,255,255,.12);border-radius:8px;padding:10px 20px;font-size:14px}\n.lmai-case-cta-section .lmai-case-cta-info-item b{font-size:16px;display:block;margin-top:2px}\n.lmai-case-cta-section .lmai-case-cta-btn{display:inline-block;background:var(--accent);color:#fff;font-size:15px;font-weight:700;padding:12px 36px;border-radius:25px;text-decoration:none;margin-top:18px;box-shadow:0 4px 12px rgba(0,0,0,.2)}\n\n\/* \u2550\u2550 \u793e\u4ea4\u5a92\u4f53\u5206\u53d1\u6587\u6848\uff08\u9690\u85cf\u533a\u5757\uff09 \u2550\u2550 *\/\n\n\/* \u2550\u2550 Related Cases \u2550\u2550 *\/\n.lmai-case-related-cases{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:14px 0;}\n.lmai-case-rel-case{background:var(--card);border:1px solid var(--border);border-radius:10px;padding:14px 16px;text-decoration:none;transition:all .2s;display:flex;flex-direction:column;gap:6px;}\n.lmai-case-rel-case:hover{border-color:var(--brand-ll);box-shadow:var(--shadow);}\n.lmai-case-rel-case .lmai-case-rc-tag{font-size:11px;font-weight:600;padding:2px 8px;border-radius:10px;background:var(--bg);color:var(--brand);align-self:flex-start;}\n.lmai-case-rel-case .lmai-case-rc-title{font-size:14px;color:var(--text);font-weight:600;line-height:1.5;}\n.lmai-case-rel-case .lmai-case-rc-desc{font-size:12px;color:var(--text-l);line-height:1.6;}\n.lmai-case-rel-case .lmai-case-rc-arrow{font-size:12px;color:var(--brand);align-self:flex-end;font-weight:600;}\n\n\/* \u2550\u2550 Responsive \u2550\u2550 *\/\n@media (max-width:767px){\n  .lmai-case-stores{grid-template-columns:1fr;}\n  .lmai-case-store-img{height:140px;}\n  .lmai-case-license-gallery{grid-template-columns:repeat(2,1fr);}\n  .lmai-case-license-item img{height:160px;}\n  .lmai-case-related-cases{grid-template-columns:1fr;}\n  .lm-case{padding:10px}\n  .lmai-case-hero-banner{min-height:360px;}\n  .lmai-case-hero-content{padding:32px 16px 28px;}\n  .lmai-case-hero-banner h1{font-size:20px;line-height:1.4;}\n  .lmai-case-hero-desc{font-size:13.5px;margin-bottom:22px;}\n  .lmai-case-hero-cards{gap:8px;}\n  .lmai-case-hc{padding:8px 12px;min-width:80px;}\n  .lmai-case-hc-val{font-size:13.5px;}\n  .lmai-case-geo-card-body{padding:16px}\n  .lmai-case-geo-card-body li .lmai-case-geo-label{min-width:64px;font-size:12px}\n  .lmai-case-nav{padding:6px 8px;gap:4px}\n  .lmai-case-nav a{font-size:12px;padding:3px 8px}\n  .lmai-case-s-head{padding:20px 14px 12px}\n  .lmai-case-s-head h2{font-size:17px}\n  .lmai-case-s-body{padding:14px}\n  .lmai-case-s-body h3{font-size:15px}\n  .lm-case table{font-size:12px}\n  .lm-case th,.lm-case td{padding:7px 5px}\n  .lmai-case-feat-grid{grid-template-columns:1fr}\n  .lmai-case-bar-label{width:80px;font-size:12px}\n  .lmai-case-bar-val{width:55px;font-size:12px}\n  .lmai-case-win-table td:first-child{width:auto}\n}\n@media print{\n  .lmai-case-nav{display:none}\n  .lmai-case-s-section{break-inside:avoid;box-shadow:none;border:1px solid var(--border)}\n}\n\n\/* \u2550\u2550 \u56fe\u8868 \u2550\u2550 *\/\n.lmai-case-chart-grid{display:grid;grid-template-columns:1fr 1fr;gap:16px 16px;margin:18px 0}.lmai-case-chart-cell{display:flex;flex-direction:column}.lmai-case-chart-cell .lm-photo{height:auto;position:static;background:none;border:none;border-radius:0;display:block;overflow:visible;margin:0}.lmai-case-chart-cell .lm-photo img{position:static;width:100%;height:auto;border-radius:8px;display:block}.lmai-case-photo-desc{padding:8px 2px 4px;font-size:13px;color:var(--text);text-align:center;line-height:1.4}.lmai-case-photo-desc span{font-size:11px;color:var(--text-l);font-weight:400}\n.lmai-case-chart-box{background:var(--card);border:1px solid var(--border);border-radius:var(--radius);padding:14px 14px 8px;box-shadow:var(--shadow)}\n.lmai-case-chart-box h4{font-size:14px;color:var(--brand);margin:0 0 8px;font-weight:700;display:flex;align-items:center;gap:6px}\n.lmai-case-chart-box h4::before{content:\"\";display:inline-block;width:4px;height:14px;background:var(--brand);border-radius:2px}\n.lmai-case-chart-canvas{width:100%;height:300px}\n.lmai-case-chart-note{font-size:12px;color:var(--text-l);margin:6px 2px 4px;line-height:1.5}\n.lm-photo{background:#eef4f4;border:1px dashed var(--brand-ll);border-radius:8px;height:108px;display:flex;flex-direction:column;align-items:center;justify-content:center;position:relative;overflow:hidden}\n.lm-photo img{width:100%;height:100%;object-fit:cover;position:absolute;inset:0;z-index:1;border-radius:8px}\n.lm-photo-ph{font-size:13px;color:var(--brand);font-weight:600;letter-spacing:.5px;position:relative;z-index:2;text-align:center;padding:4px}.alt-desc{position:relative;z-index:2}\n.lmai-case-link-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:12px;margin:14px 0}\n.lmai-case-link-card{display:block;background:var(--card);border:1px solid var(--border);border-left:4px solid var(--brand);border-radius:8px;padding:12px 14px;text-decoration:none;color:inherit;transition:.2s;box-shadow:var(--shadow)}\n.lmai-case-link-card:hover{border-left-color:var(--accent);transform:translateY(-2px)}\n.lmai-case-lc-t{display:block;font-weight:700;color:var(--brand);font-size:14px}\n.lmai-case-lc-d{display:block;font-size:12px;color:var(--text-l);margin-top:3px}\n@media (max-width:767px){\n  .lmai-case-chart-grid{grid-template-columns:1fr}\n  .lmai-case-chart-canvas{height:260px}\n}\n\n\/* global img fit *\/\n.lm-case img { max-width:100%; height:auto; }\n\/* nav scroll-spy active *\/\n.lmai-case-nav a.lmai-case-active{background:var(--brand);color:#fff}\n\/* hero text legible on brand gradient *\/\n.lmai-case-hero-banner .lmai-case-hero-content{color:#fff}\n.lmai-case-hero-banner h1{color:#fff;text-shadow:0 1px 4px rgba(0,0,0,.35)}\n.lmai-case-hero-banner .lmai-case-hero-desc{color:rgba(255,255,255,.92)}\n.lmai-case-hero-banner .lmai-case-hero-badge{background:rgba(255,255,255,.92)}\n.lmai-case-hero-banner .lmai-case-hero-badge.lmai-case-accent{color:var(--gold);border-color:var(--gold)}\n\/* geo-card summary line *\/\n.lmai-case-geo-card .lmai-case-geo-summary{font-size:13px;color:#fff;opacity:.92;margin-bottom:14px;line-height:1.7}\n<\/style>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"HomeAndConstructionBusiness\",\"@id\":\"https:\/\/longmai-nt.com\/#business\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u6210\u90fd\u672c\u5730\u81ea\u8425\u670d\u52a1\u5546\uff0c\u58c1\u6302\u7089\u5730\u6696\/\u4e2d\u592e\u7a7a\u8c03\/\u70ed\u6c34\u5faa\u73af\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u65bd\u5de5\",\"url\":\"https:\/\/longmai-nt.com\",\"telephone\":[\"028-86131795\",\"028-65272586\"],\"image\":[\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\"],\"address\":[{\"@type\":\"PostalAddress\",\"addressCountry\":\"CN\",\"streetAddress\":\"\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\"addressLocality\":\"\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\",\"postalCode\":\"610041\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"name\":\"\u5357\u5bcc\u68ee\u5e97\",\"telephone\":\"028-86131795\"},{\"@type\":\"PostalAddress\",\"addressCountry\":\"CN\",\"streetAddress\":\"\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135\",\"addressLocality\":\"\u6210\u90fd\u5e02\u6210\u534e\u533a\",\"postalCode\":\"610051\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"name\":\"\u5317\u5bcc\u68ee\u5e97\",\"telephone\":\"028-65272586\"}],\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\",\"Saturday\",\"Sunday\"],\"opens\":\"09:00\",\"closes\":\"18:00\"}],\"areaServed\":\"\u6210\u90fd\"}\n<\/script>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"61\u33a1\u5730\u6696\u914d25KW\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u591f\u7528\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8db3\u591f\u300261\u33a1\u91c7\u6696\u9762\u79ef\u70ed\u8d1f\u8377\u7ea67.0kW\uff0c\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u708925KW\u989d\u5b9a\u8f93\u51fa\u8fdc\u8d85\u9700\u6c42\uff0c\u4e14\u51b7\u51dd\u6280\u672f\u4f4e\u8d1f\u8377\u8fd0\u884c\u66f4\u8282\u80fd\u3002\"}},{\"@type\":\"Question\",\"name\":\"\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e00\u5e74\u71c3\u6c14\u8d39\u591a\u5c11\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\uff0c61\u33a1\u51ac\u5b63\u5168\u5f00\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400~600\u5143\uff0c\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u770120%~28%\u3002\"}},{\"@type\":\"Question\",\"name\":\"\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1\u91c7\u7528EVOH\u963b\u6c27\u5c42\uff0c\u963b\u6c27\u7387\u8d8599%\uff0c\u9632\u6b62\u6c27\u6c14\u6e17\u5165\u8150\u8680\u91d1\u5c5e\u90e8\u4ef6\uff0c\u914d\u5408\u767d\u6676\u677f\u548c\u7845\u6676\u7f51\u4fdd\u6e29\uff0c\u7cfb\u7edf\u5bff\u547d\u66f4\u957f\u3001\u70ed\u6548\u7387\u66f4\u9ad8\u3002\"}},{\"@type\":\"Question\",\"name\":\"\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\u503c\u4e0d\u503c\u5f97\u88c5\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\u652f\u6301\u5206\u5ba4\u6e29\u63a7+\u624b\u673a\u8fdc\u7a0b\uff0c\u5e38\u4f4f2\u4eba\u53ef\u6309\u9700\u5f00\u5173\uff0c\u907f\u514d\u7a7a\u623f\u65e0\u6548\u8017\u80fd\uff0c\u6295\u5165\u7ea62000~3000\u5143\uff0c1~2\u5e74\u901a\u8fc7\u8282\u7701\u71c3\u6c14\u8d39\u56de\u6536\u3002\"}},{\"@type\":\"Question\",\"name\":\"\u767d\u6676\u677f\u548c\u7845\u6676\u7f51\u6709\u4ec0\u4e48\u7528\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u767d\u6676\u677f\u662f\u9ad8\u5bc6\u5ea6\u6324\u5851\u4fdd\u6e29\u677f\uff0c\u5bfc\u70ed\u7cfb\u6570\u4f4e\u81f30.028W\/m\u00b7K\uff0c\u9694\u70ed\u6027\u80fd\u4f18\u4e8e\u666e\u901a\u6ce1\u6cab\u677f\uff1b\u7845\u6676\u7f51\u7528\u4e8e\u52a0\u56fa\u56de\u586b\u5c42\u6297\u88c2\uff0c\u4e24\u8005\u914d\u5408\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931\u7ea615%~20%\u3002\"}}]}\n<\/script>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Article\",\"headline\":\"\u6210\u90fd\u9526\u6c5f\u7247\u533a\u8521\u5148\u751f\u5730\u6696\u6848\u4f8b\uff5c61\u33a1\u51b7\u51dd\u7089\u65b9\u6848\uff5c\u9f99\u8109\u6696\u901a\",\"description\":\"\u6210\u90fd\u9526\u6c5f\u7247\u533a\u8521\u5148\u751f61\u33a1\u5957\u4e09\u5e73\u5c42\u5730\u6696\u6848\u4f8b\uff0c\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u7845\u6676\u7f51+\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3002\",\"datePublished\":\"2026-07-24\",\"dateModified\":\"2026-07-24\",\"author\":{\"@type\":\"Person\",\"name\":\"\u5f90\u65b0\u5e73\",\"@id\":\"https:\/\/longmai-nt.com\/#consultant\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-logo.png\"}},\"image\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-fsminning-cai-dnps-01.jpg\"}\n<\/script>\n<div class=\"lm-case\">\n<section class=\"lmai-case-hero-banner\" id=\"top\">\n  <div class=\"lmai-case-hero-bg\" style=\"background:linear-gradient(135deg,#0D7C7F 0%,#1A9B9E 100%)\"><\/div>\n  <div class=\"lmai-case-hero-overlay\"><\/div>\n  <div class=\"lmai-case-hero-content\">\n    <div class=\"lmai-case-hero-badges\">\n      <span class=\"lmai-case-hero-badge\">\u771f\u5b9e\u843d\u5730\u6848\u4f8b<\/span>\n      <span class=\"lmai-case-hero-badge lmai-case-accent\">\u4e94\u6b65\u6cd5<\/span>\n    <\/div>\n    <h2>\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u8521\u5148\u751f<br>\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf<\/h2>\n    <p class=\"lmai-case-hero-desc\">\u5957\u5185\u7ea6<strong>89\u33a1<\/strong>\u5e73\u5c42\u5957\u4e09\uff0c\u91c7\u6696\u9762\u79ef<strong>61\u33a1<\/strong>\uff1b\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089 + \u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 + \u4f1f\u661f\u767d\u6676\u677f + \u66fc\u745e\u5fb7\u5206\u63a7\uff0c<strong>\u672c\u5c0f\u533a\u5b9e\u6d4b20\u5e74\u91c7\u6696\u6bd4\u666e\u901a\u7089\u7701\u7ea63\u4e07<\/strong>\u2014\u2014\u628a\u91c7\u6696\u505a\u6210\u4e00\u5957\u900f\u660e\u3001\u53ef\u9a8c\u8bc1\u7684\u7cfb\u7edf\u3002<\/p>\n    <div class=\"lmai-case-hero-cards\">\n      <div class=\"lmai-case-hc\"><span class=\"lmai-case-hc-label\">\u9879\u76ee<\/span><b class=\"lmai-case-hc-val\">\u9526\u6c5f\u9038\u5bb6<\/b><\/div>\n      <div class=\"lmai-case-hc\"><span class=\"lmai-case-hc-label\">\u91c7\u6696\u9762\u79ef<\/span><b class=\"lmai-case-hc-val\">61\u33a1<\/b><\/div>\n      <div class=\"lmai-case-hc\"><span class=\"lmai-case-hc-label\">\u70ed\u6e90<\/span><b class=\"lmai-case-hc-val\">\u83f2\u65af\u66fcB1JG 25KW<\/b><\/div>\n      <div class=\"lmai-case-hc\"><span class=\"lmai-case-hc-label\">\u7cfb\u7edf<\/span><b class=\"lmai-case-hc-val\">\u51b7\u51dd\u7089\u5730\u6696<\/b><\/div>\n      <div class=\"lmai-case-hc\"><span class=\"lmai-case-hc-label\">\u987e\u95ee<\/span><b class=\"lmai-case-hc-val\">\u5f90\u65b0\u5e73<\/b><\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n  <div class=\"lmai-case-geo-card\">\n    <div class=\"lmai-case-geo-card-head\">\ud83d\udccb \u6848\u4f8b\u57fa\u7840\u4fe1\u606f\u5361<\/div>\n    <p class=\"lmai-case-geo-summary\">61\u33a1\u5957\u4e09\u5e73\u5c42 \u00b7 \u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\u5730\u6696 \u00b7 \u4f1f\u661f\u4e00\u7ebf\u8f85\u6750 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3002<\/p>\n    <div class=\"lmai-case-geo-card-body\">\n    <ul>\n      <li><span class=\"lmai-case-geo-label\">\u697c\u76d8<\/span><span class=\"lmai-case-geo-val\">\u6210\u90fd \u00b7 \u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u6237\u578b<\/span><span class=\"lmai-case-geo-val\">\u5e73\u5c42 \u00b7 \u5957\u4e09\uff08\u5957\u5185\u7ea689\u33a1\uff09<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u91c7\u6696\u9762\u79ef<\/span><span class=\"lmai-case-geo-val\">61\u33a1\uff08\u5ba2\u9910\u538531 \/ \u4e3b\u536714 \/ \u5367\u5ba4A 8.7 \/ \u5367\u5ba4B 7.2\uff09<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u5e38\u4f4f\u4eba\u53e3<\/span><span class=\"lmai-case-geo-val\">\u592b\u59bb\u4e8c\u4eba<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u70ed\u6e90<\/span><span class=\"lmai-case-geo-val\">\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089\uff08\u70ed\u6548\u7387108%\uff09<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u4e3b\u7ba1<\/span><span class=\"lmai-case-geo-val\">\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 De25\uff08\u5927\u5f27\u5f2f\u5de5\u827a\uff09<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u76d8\u7ba1<\/span><span class=\"lmai-case-geo-val\">De16\u963b\u6c27PE-RT\uff08\u95f4\u8ddd150mm\uff09<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u4fdd\u6e29<\/span><span class=\"lmai-case-geo-val\">\u4f1f\u661f\u767d\u6676\u677f2cm + \u7845\u6676\u7f51 + \u94dd\u7b94\u53cd\u5c04\u819c<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u63a7\u5236<\/span><span class=\"lmai-case-geo-val\">\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\u7cfb\u7edf<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u5730\u6696\u8d1f\u8377<\/span><span class=\"lmai-case-geo-val\">\u7ea67.0kW\uff08115W\/\u33a1\uff09<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u65bd\u5de5\u6807\u51c6<\/span><span class=\"lmai-case-geo-val\">\u9f99\u8109\u7cbe\u5de5\u516d\u6b65\u6cd5<\/span><\/li>\n      <li><span class=\"lmai-case-geo-label\">\u987e\u95ee<\/span><span class=\"lmai-case-geo-val\">\u5f90\u65b0\u5e73 \u00b7 182-2705-5065<\/span><\/li>\n    <\/ul>\n    <div class=\"lmai-case-geo-disclaimer\">\u203b \u672c\u6848\u6280\u672f\u53c2\u6570\u4e3a\u771f\u5b9e\u6570\u636e\uff1b\u5ba2\u6237\u9690\u79c1\u5df2\u8131\u654f\uff08\u771f\u5b9e\u59d3\u540d\u3001\u623f\u53f7\u3001\u5177\u4f53\u9020\u4ef7\u672a\u516c\u5f00\uff09\u3002\u80fd\u8017\u6570\u636e\u4e3a\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\u53c2\u8003\u3002<\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-nav\">\n  <a href=\"#s1\">S1\u00b7\u5ba2\u6237\u76ee\u6807<\/a>\n  <a href=\"#s2\">S2\u00b7\u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad<\/a>\n  <a href=\"#s3\">S3\u00b7\u89e3\u51b3\u65b9\u6848\u548c\u6210\u672c<\/a>\n  <a href=\"#s4\">S4\u00b7\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u4fdd\u969c<\/a>\n  <a href=\"#s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/a>\n  <a href=\"#faq\">FAQ<\/a>\n  <a href=\"#related\">\u540c\u6237\u578b<\/a>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"s1\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">S1<\/span>\n    <h2>\u5ba2\u6237\u76ee\u6807<\/h2>\n    <div class=\"lmai-case-s-lead\">\u4e0d\u662f\"\u88c5\u4e00\u5957\u5730\u6696\"\uff0c\u662f\u7ed9\u5168\u5bb6\u4e00\u5957<strong>\"\u8f85\u6750\u5168\u77e5\u540d\u54c1\u724c\u3001\u540e\u671f\u771f\u8282\u80fd\u3001\u5de5\u827a\u770b\u5f97\u89c1\"<\/strong>\u7684\u91c7\u6696\u7cfb\u7edf\u2014\u2014\u8fd9\u662f\u8521\u5148\u751f\u5bf9\u8fd9\u5957\u51b7\u51dd\u7089\u5730\u6696\u5b9a\u7684\u6838\u5fc3\u76ee\u6807\u3002<\/div>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n\n    <h3>\u9879\u76ee\u6982\u51b5\u4e0e\u6838\u5fc3\u8bc9\u6c42<\/h3>\n    <p>\u8521\u5148\u751f\u5bb6\u4f4d\u4e8e\u6210\u90fd\u9526\u6c5f\u533a\u672c\u5c0f\u533a\uff0c\u5957\u5185\u7ea6<strong>89\u33a1<\/strong>\uff0c\u592b\u59bb\u4e8c\u4eba\u5e38\u4f4f\uff0c\u6ce8\u91cd\u54c1\u8d28\u4e0e\u8282\u80fd\u3002\u6c9f\u901a\u4e2d\u4ed6\u5df2\u7ecf\u505a\u4e86\u529f\u8bfe\uff0c\u4e86\u89e3\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u7701\u7684\u4f18\u52bf\uff0c\u4e3b\u52a8\u9009\u62e9\u83f2\u65af\u66fc\u51b7\u51dd\u7089 + \u4e00\u7ebf\u8f85\u6750\u65b9\u6848\u3002\u6838\u5fc3\u8bc9\u6c42\u5982\u4e0b\uff1a<\/p>\n\n    <div class=\"lmai-case-card lmai-case-card-accent\" style=\"margin:12px 0\">\n      <p style=\"font-size:14px;font-style:italic;color:var(--text)\">\u8521\u5148\u751f\u5bb6\u4f4f\u9526\u6c5f\u533a\u672c\u5c0f\u533a\uff0c\u5957\u5185\u7ea689\u33a1\u5e73\u5c42\u5957\u4e09\uff0c\u91c7\u6696\u9762\u79ef61\u33a1\uff0c\u592b\u59bb\u4e8c\u4eba\u5e38\u4f4f\u3002\u88c5\u4fee\u524d\u671f\u5bf9\u6bd4\u8fc7\u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089\u591a\u6b3e\u65b9\u6848\uff0c\u6838\u5fc3\u987e\u8651\u957f\u671f\u91c7\u6696\u6210\u672c\u8fc7\u9ad8\u3001\u9690\u853d\u5de5\u7a0b\u6015\u5077\u5de5\u51cf\u6599\u3002\u7ed3\u5408\u6210\u90fd\u51ac\u5b63\u9634\u51b7\u7684\u6c14\u5019\uff0c\u6700\u7ec8\u6572\u5b9a\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089 + \u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 + \u4f1f\u661f\u767d\u6676\u677f + \u66fc\u745e\u5fb7\u5206\u63a7\u2014\u2014\u4e00\u5957\u70ed\u6e90\u53ef\u9760\u3001\u8f85\u6750\u8fc7\u786c\u3001\u5de5\u827a\u53ef\u67e5\u7684\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf\u3002<\/p>\n    <\/div>\n    <ul>\n      <li><strong>\u8f85\u6750\u5168\u77e5\u540d<\/strong>\uff1a\u4e3b\u7ba1\/\u4fdd\u6e29\/\u63a7\u5236\u5168\u4e00\u7ebf\u54c1\u724c\uff0c\u4e0d\u4e3a\u964d\u6210\u672c\u6362\u6742\u724c<\/li>\n      <li><strong>\u540e\u671f\u771f\u8282\u80fd<\/strong>\uff1a\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u770120%~28%\uff0c\u672c\u5c0f\u533a\u5b9e\u6d4b\u53ef\u8bc1<\/li>\n      <li><strong>\u5de5\u827a\u770b\u5f97\u89c1<\/strong>\uff1a\u5173\u952e\u5de5\u827a\u4e0d\u7f29\u6c34\u3001\u53ef\u67e5\u9a8c\u3001\u5168\u7a0b\u7559\u6863<\/li>\n      <li><strong>\u6027\u4ef7\u6bd4\u5408\u7406<\/strong>\uff1a\u4e0d\u4e3a\u6ea2\u4ef7\u4e70\u5355\uff0c\u4f46\u6bcf\u4e00\u5206\u94b1\u82b1\u5f97\u660e\u767d<\/li>\n    <\/ul>\n\n    <div class=\"lmai-case-card lmai-case-card-brand\" style=\"margin-top:14px\">\n      <p><strong>\u6838\u5fc3\u8bc9\u6c42\u4e00\u53e5\u8bdd<\/strong>\uff1a\u60a8\u5df2\u7ecf\u505a\u4e86\u529f\u8bfe\uff0c\u77e5\u9053\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u7701\u3002\u60a8\u8981\u7684\u4e0d\u662f\u6700\u4fbf\u5b9c\uff0c\u800c\u662f\u4e00\u5957\u957f\u671f\u66f4\u7701\u94b1\u3001\u8f85\u6750\u8fc7\u786c\u3001\u5de5\u827a\u770b\u5f97\u89c1\u7684\u91c7\u6696\u7cfb\u7edf\u3002\u83f2\u65af\u66fc\u51b7\u51dd\u7089 + \u4f1f\u661f5\u5c42\u963b\u6c27 + \u767d\u6676\u677f + \u66fc\u745e\u5fb7\u5206\u63a7\u65b9\u6848\u7684\u6838\u5fc3\u4ef7\u503c\uff1a\u4e00\u53f0\u51b7\u51dd\u7089\u51ac\u5b63\u9a71\u52a8\u5730\u6696\uff0c\u70ed\u6548\u7387108%\uff0c\u7535\u8d39...\u4e0d\uff0c\u71c3\u6c14\u8d39\u6bd4\u666e\u901a\u7089\u7701\u3002<\/p>\n    <\/div>\n\n    <h3>\u4e09\u65b9\u5171\u8d62\uff1a\u5404\u81ea\u7684\"\u8d62\"\u662f\u4ec0\u4e48<\/h3>\n    <table class=\"lmai-case-win-table\">\n      <thead>\n        <tr><th>\u89d2\u8272<\/th><th>\u76ee\u6807\uff08\u8d62\u4ec0\u4e48\uff09<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u8521\u5148\u751f\uff08\u4e1a\u4e3b\uff09<\/td><td>\u4e00\u5957\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u3001\u5de5\u827a\u900f\u660e\u7684\u91c7\u6696\u7cfb\u7edf<\/td><\/tr>\n        <tr><td>\u9f99\u8109\u6696\u901a<\/td><td>\u628a\"\u51b7\u51dd\u7089+\u4e00\u7ebf\u8f85\u6750+\u516d\u6b65\u6cd5\"\u505a\u6210\u53ef\u590d\u5236\u3001\u53ef\u9a8c\u8bc1\u7684\u6807\u51c6\u65b9\u6848\uff0c\u7528\u6570\u636e\u8bf4\u8bdd<\/td><\/tr>\n        <tr><td>\u5bb6\u4eba\uff08\u4f7f\u7528\u8005\uff09<\/td><td>\u51ac\u5b63\u6052\u6e29\u8212\u9002\u3001\u6309\u9700\u5206\u5ba4\u63a7\u6e29\u3001\u5b89\u9759\u65e0\u6270<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <p style=\"font-size:13px;color:var(--success);margin-top:8px\">\u2714 \u4e09\u65b9\u76ee\u6807\u4e0d\u51b2\u7a81\uff1a\u5ba2\u6237\u8981\"\u54c1\u8d28+\u8282\u80fd\"\u3001\u9f99\u8109\u8981\"\u6807\u51c6\"\u3001\u5bb6\u4eba\u8981\"\u8212\u9002\"\u2014\u2014\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u63a7\u65b9\u6848\u6070\u597d\u540c\u65f6\u6210\u7acb\u3002<\/p>\n\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"s2\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">S2<\/span>\n    <h2>\u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad<\/h2>\n    <div class=\"lmai-case-s-lead\">\u8521\u5148\u751f\u5df2\u7ecf\u505a\u4e86\u529f\u8bfe\uff0c\u77e5\u9053\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u7701\u3002\u8bca\u65ad\u8981\u505a\u7684\uff0c\u662f\u628a\u4ed6\u6bcf\u4e00\u53e5\u8bdd\u80cc\u540e\u7684\u6280\u672f\u672c\u8d28\u62c6\u6e05\u695a\uff0c\u7528\u6570\u636e\u548c\u539f\u7406\u7ed9\u51fa\u9f99\u8109\u7684\u5224\u65ad\u3002<\/div>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n\n    <h3>2.1 \u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n    <table>\n      <tr><td style=\"text-align:right;color:var(--text-l);width:30%\">\u9879\u76ee\u5730\u5740<\/td><td style=\"text-align:left\">\u6210\u90fd \u00b7 \u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6<\/td><td style=\"text-align:right;color:var(--text-l);width:30%\">\u5957\u5185\u9762\u79ef<\/td><td style=\"text-align:left\">\u7ea6 89\u33a1<\/td><\/tr>\n      <tr><td style=\"text-align:right;color:var(--text-l)\">\u6237\u578b<\/td><td style=\"text-align:left\">\u5e73\u5c42 \u00b7 \u5957\u4e09<\/td><td style=\"text-align:right;color:var(--text-l)\">\u5e38\u4f4f\u4eba\u53e3<\/td><td style=\"text-align:left\">\u592b\u59bb\u4e8c\u4eba<\/td><\/tr>\n      <tr><td style=\"text-align:right;color:var(--text-l)\">\u5ba2\u9910\u5385<\/td><td style=\"text-align:left\">31\u33a1<\/td><td style=\"text-align:right;color:var(--text-l)\">\u4e3b\u5367<\/td><td style=\"text-align:left\">14\u33a1<\/td><\/tr>\n      <tr><td style=\"text-align:right;color:var(--text-l)\">\u5367\u5ba4A<\/td><td style=\"text-align:left\">8.7\u33a1<\/td><td style=\"text-align:right;color:var(--text-l)\">\u5367\u5ba4B<\/td><td style=\"text-align:left\">7.2\u33a1<\/td><\/tr>\n      <tr><td style=\"text-align:right;color:var(--text-l)\">\u91c7\u6696\u9762\u79ef<\/td><td style=\"text-align:left\">61\u33a1<\/td><td style=\"text-align:right;color:var(--text-l)\">\u5730\u6696\u8d1f\u8377<\/td><td style=\"text-align:left\">\u7ea67.0kW\uff08115W\/\u33a1\uff09<\/td><\/tr>\n      <tr><td style=\"text-align:right;color:var(--text-l)\">\u70ed\u6e90<\/td><td style=\"text-align:left\">\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089<\/td><td style=\"text-align:right;color:var(--text-l)\">\u63a7\u5236<\/td><td style=\"text-align:left\">\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf<\/td><\/tr>\n    <\/table>\n\n    <h3>2.2 \u9700\u6c42-\u75db\u70b9-\u8bca\u65ad\u5bf9\u9f50\u8868<\/h3>\n    <p style=\"font-size:13px;color:var(--brand);font-weight:600;margin-bottom:6px\">\u7ed3\u8bba\uff1a\u8521\u5148\u751f\u7684\u6838\u5fc3\u8bc9\u6c42\u662f\"\u8f85\u6750\u5168\u77e5\u540d+\u540e\u671f\u771f\u8282\u80fd\"\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u63a7\u65b9\u6848\u66f4\u8d34\u5408\u54c1\u8d28\u4e0e\u8282\u80fd\u8bc9\u6c42\u3002<\/p>\n    <table>\n      <thead>\n        <tr><th>#<\/th><th>\u5ba2\u6237\u8bf4\u7684<\/th><th>\u80cc\u540e\u7684\u6280\u672f\u672c\u8d28<\/th><th>\u6211\u4eec\u7684\u8bca\u65ad<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>1<\/td><td>\"\u8f85\u6750\u4e00\u5b9a\u8981\u77e5\u540d\u54c1\u724c\"<\/td><td>\u6742\u724c\u8f85\u6750\u963b\u6c27\u5dee\u3001\u6613\u8150\u8680\u91d1\u5c5e\u90e8\u4ef6\u3001\u5bff\u547d\u77ed<\/td><td>\u914d\u7f6e\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1\uff08\u963b\u6c27\u738799%+\uff09+ \u4f1f\u661f\u767d\u6676\u677f + \u66fc\u745e\u5fb7\u5206\u63a7\uff0c\u5168\u90e8\u884c\u4e1a\u4e00\u7ebf<\/td><\/tr>\n        <tr><td>2<\/td><td>\"\u62c5\u5fc3\u540e\u671f\u71c3\u6c14\u8d39\u8fc7\u9ad8\"<\/td><td>\u666e\u901a\u7089\u70ed\u6548\u7387\u4ec590%~93%\uff0c\u957f\u671f\u71c3\u6c14\u8d39\u9ad8<\/td><td>\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\uff0c\u56de\u6536\u70df\u6c14\u4f59\u70ed\uff1b\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\u6bd4\u666e\u901a\u7089\u770120%~28%<\/td><\/tr>\n        <tr><td>3<\/td><td>\"\u65bd\u5de5\u5de5\u827a\u4e0d\u900f\u660e\"<\/td><td>\u9690\u853d\u5de5\u7a0b\u96be\u67e5\u9a8c\uff0c\u6015\u5077\u5de5\u51cf\u6599\u3001\u540e\u671f\u6f0f\u6c34<\/td><td>\u7cbe\u5de5\u516d\u6b65\u6cd5 + 36\u9879\u8282\u70b9\u9a8c\u6536 + \u5168\u7a0b\u62cd\u7167\u7559\u6863 + 0.8MPa\/24h\u4fdd\u538b\uff0c\u8fc7\u7a0b\u53ef\u8ffd\u6eaf<\/td><\/tr>\n        <tr><td>4<\/td><td>\"\u4e0d\u76f2\u76ee\u8ffd\u6c42\u4f4e\u4ef7\"<\/td><td>\u613f\u4e3a\u54c1\u8d28\u4ed8\u8d39\uff0c\u4f46\u8981\u6c42\u6bcf\u5206\u94b1\u82b1\u5f97\u660e\u767d<\/td><td>\u900f\u660e\u62a5\u4ef7 + \u54c1\u8d28\u5012\u63a8\u6e05\u5355 + 20\u5e74\u603b\u8d26\u8bc1\u660e\uff0c\u5408\u7406\u9884\u7b97\u914d\u7f6e\u51b7\u51dd\u7089+\u4e00\u7ebf\u8f85\u6750<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>2.3 \u9690\u6027\u7269\u7406\u7ea6\u675f\u8bc6\u522b<\/h3>\n    <table>\n      <thead><tr><th>\u7ea6\u675f\u7c7b\u578b<\/th><th>\u8bc6\u522b\u7ed3\u679c<\/th><th>\u5f71\u54cd<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5b89\u88c5\u7a7a\u95f4<\/td><td>\u9505\u7089 + \u5206\u96c6\u6c34\u5668\u9700\u9884\u7559\u5b89\u88c5\u4f4d\u7f6e<\/td><td>\u5df2\u7eb3\u5165\u65b9\u6848\uff0c\u8fdc\u79bb\u5367\u5ba4\u964d\u566a<\/td><\/tr>\n        <tr><td>\u5efa\u7b51\u7ed3\u6784<\/td><td>\u5e73\u5c42\u5957\u4e09\uff0c\u5e38\u89c4\u5c42\u9ad8<\/td><td>\u6709\u5229\uff0c\u76d8\u7ba1\u94fa\u8bbe\u65e0\u969c\u788d<\/td><\/tr>\n        <tr><td>\u80fd\u6e90\u6761\u4ef6<\/td><td>\u71c3\u6c14 + \u5e02\u7535\u5145\u8db3<\/td><td>\u6ee1\u8db3\u51b7\u51dd\u7089+\u5206\u63a7\u7528\u7535<\/td><\/tr>\n        <tr><td>\u7ba1\u8def\u6761\u4ef6<\/td><td>5\u56de\u8def\u76d8\u7ba1 + \u4e3b\u7ba1\u8d70\u5411<\/td><td>\u5df2\u89c4\u5212\uff0c\u5ba2\u9910\u53852\u8def\u3001\u4e3b\u5367\/\u5367\u5ba4A\/\u5367\u5ba4B\u54041\u8def<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>2.4 \u9f99\u8109\u7684\u5224\u65ad<\/h3>\n    <div class=\"lmai-case-card lmai-case-card-brand\">\n      <p>\u60a8\u8981\u7684\u4e0d\u662f\u6700\u4fbf\u5b9c\uff0c\u800c\u662f\u4e00\u5957<strong>\u957f\u671f\u66f4\u7701\u94b1\u3001\u8f85\u6750\u8fc7\u786c\u3001\u5de5\u827a\u770b\u5f97\u89c1<\/strong>\u7684\u91c7\u6696\u7cfb\u7edf\u3002<\/p>\n      <p style=\"margin-top:8px\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089 + \u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 + \u767d\u6676\u677f + \u7845\u6676\u7f51 + \u66fc\u745e\u5fb7\u5206\u63a7\uff0c\u56db\u91cd\u63aa\u65bd\u53e0\u52a0\uff0c\u6070\u597d\u540c\u65f6\u6ee1\u8db3\"\u54c1\u8d28 + \u8282\u80fd + \u900f\u660e\"\u4e09\u5927\u8bc9\u6c42\u2014\u2014\u8fd9\u6b63\u662f\u672c\u65b9\u6848\u7684\u6838\u5fc3\u4ef7\u503c\u3002<\/p>\n    <\/div>\n\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"s3\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">S3<\/span>\n    <h2>\u89e3\u51b3\u65b9\u6848\u548c\u6210\u672c<\/h2>\n    <div class=\"lmai-case-s-lead\">\u4e09\u4ef6\u4e8b\u4e00\u6b21\u644a\u5f00\uff1a\u51b7\u51dd\u7089\u5730\u6696\u662f\u4ec0\u4e48\u3001\u8bbe\u5907\u600e\u4e48\u9009\u914d\u300120\u5e74\u603b\u8d26\u600e\u4e48\u7b97\u2014\u2014\u6bcf\u4e00\u9879\u90fd\u6709\u6570\u636e\u3001\u6709\u539f\u7406\u3001\u53ef\u9a8c\u8bc1\u3002<\/div>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n\n    <h3>3.1 \u6982\u5ff5\u6f84\u6e05\uff1a\u4ec0\u4e48\u662f\u51b7\u51dd\u7089\u5730\u6696\uff1f<\/h3>\n    <div class=\"lmai-case-card lmai-case-card-brand\">\n      <p style=\"margin-bottom:10px\"><strong>\u5927\u767d\u8bdd\uff1a<\/strong>\u51b7\u51dd\u7089\u5730\u6696\u5c31\u50cf\"\u4f1a\u8fc7\u65e5\u5b50\u7684\u9505\u7089\"\u2014\u2014\u5b83\u628a\u666e\u901a\u7089\u6392\u6389\u7684\u70df\u6c14\u4f59\u70ed\u56de\u6536\u518d\u5229\u7528\uff0c\u70ed\u6548\u7387\u4ece90%~93%\u63d0\u5347\u5230108%\uff0c\u76f8\u5f53\u4e8e\u4e00\u5ea6\u6c14\u70e7\u51fa\u66f4\u591a\u70ed\u3002<\/p>\n      <p style=\"color:var(--text-l);font-size:14px;line-height:1.8\"><strong>\u4e3a\u4ec0\u4e48\u9009\u51b7\u51dd\u7089\u800c\u4e0d\u662f\u666e\u901a\u7089\uff1f<\/strong> \u56e0\u4e3a\u8521\u5148\u751f\u6ce8\u91cd\u540e\u671f\u8282\u80fd\u3002\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u4e2d\u6c34\u84b8\u6c14\u51b7\u51dd\u7684\u6c7d\u5316\u6f5c\u70ed\uff0c\u914d\u5408\u4f4e\u6e29\u5730\u6696\uff08\u4f9b\u6c3445\u2103\u4ee5\u4e0b\uff09\u6548\u7387\u66f4\u9ad8\uff1b\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\uff0c\u51ac\u5b63\u5168\u5f00\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400~600\u5143\uff0c\u6bd4\u666e\u901a\u7089\u770120%~28%\u3002<\/p>\n    <\/div>\n\n    <h3>3.2 \u7cfb\u7edf\u65b9\u6848\uff1a\u70ed\u6e90 + \u8f85\u914d + \u672b\u7aef + \u63a7\u5236<\/h3>\n    <div class=\"lmai-case-feat-grid\">\n      <div class=\"lmai-case-feat-item\"><div class=\"lmai-case-icon\" style=\"background:var(--brand-ll)\">\ud83d\udd25<\/div><div class=\"lmai-case-ct\"><h4>\u70ed\u6e90<\/h4><p>\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089<\/p><\/div><\/div>\n      <div class=\"lmai-case-feat-item\"><div class=\"lmai-case-icon\" style=\"background:var(--brand-ll)\">\ud83d\udd27<\/div><div class=\"lmai-case-ct\"><h4>\u8f85\u914d<\/h4><p>\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 + \u5927\u5f27\u5f2f<\/p><\/div><\/div>\n      <div class=\"lmai-case-feat-item\"><div class=\"lmai-case-icon\" style=\"background:var(--brand-ll)\">\u2744\ufe0f<\/div><div class=\"lmai-case-ct\"><h4>\u672b\u7aef\u00b7\u4fdd\u6e29<\/h4><p>De16\u963b\u6c27\u76d8\u7ba1 + \u767d\u6676\u677f+\u7845\u6676\u7f51<\/p><\/div><\/div>\n      <div class=\"lmai-case-feat-item\"><div class=\"lmai-case-icon\" style=\"background:var(--brand-ll)\">\ud83c\udf9b\ufe0f<\/div><div class=\"lmai-case-ct\"><h4>\u63a7\u5236<\/h4><p>\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\u7cfb\u7edf<\/p><\/div><\/div>\n    <\/div>\n    <div class=\"lmai-case-card lmai-case-card-brand\" style=\"margin-top:14px\">\n      <p style=\"margin-bottom:8px\"><strong>\ud83d\udd25 \u70ed\u6e90 \u00b7 \u83f2\u65af\u66fcB1JG\u51b7\u51dd\u708925KW<\/strong>\uff1a\u5168\u9884\u6df7\u71c3\u70e7+\u51b7\u51dd\u6362\u70ed\uff0c\u70ed\u6548\u7387108%\uff0c\u4f4eNOx 5\u7ea7\uff0c15~20\u5e74\u8bbe\u8ba1\u5bff\u547d\u300225KW\u5bf961\u33a1\uff08\u70ed\u8d1f\u8377\u7ea67.0kW\uff09\u7ef0\u7ef0\u6709\u4f59\uff0c\u4f4e\u8d1f\u8377\u8fd0\u884c\u51b7\u51dd\u6548\u7387\u66f4\u9ad8\u3002<\/p>\n      <p style=\"margin-bottom:8px\"><strong>\ud83d\udd27 \u8f85\u914d \u00b7 \u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 + \u5927\u5f27\u5f2f<\/strong>\uff1aEVOH\u963b\u6c27\u5c42\u963b\u6c27\u738799%+\uff0c\u9632\u6b62\u6c27\u6c14\u6e17\u5165\u8150\u8680\u7cfb\u7edf\uff1b\u4e3b\u7ba1\u5927\u5f27\u5f2f\u5de5\u827a\u51cf\u5c11\u6c34\u963b40%+\uff0c\u63d0\u5347\u5faa\u73af\u6548\u7387\u3002<\/p>\n      <p style=\"margin-bottom:8px\"><strong>\u2744\ufe0f \u672b\u7aef\u00b7\u4fdd\u6e29 \u00b7 De16\u963b\u6c27\u76d8\u7ba1+\u767d\u6676\u677f+\u7845\u6676\u7f51<\/strong>\uff1a2cm\u767d\u6676\u677f\u5bfc\u70ed\u7cfb\u6570\u4f4e\u81f30.028W\/m\u00b7K\uff0c\u51cf\u5c11\u5411\u4e0b\u6563\u5931\u7ea615%~20%\uff1b\u7845\u6676\u7f51\u52a0\u56fa\u56de\u586b\u5c42\u6297\u88c2\u3002<\/p>\n      <p><strong>\ud83c\udf9b\ufe0f \u63a7\u5236 \u00b7 \u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf<\/strong>\uff1a\u58c1\u6302\u7089\"\u770b\u6c34\u6e29\"\u542f\u505c\uff0c\u6ca1\u6709\u8054\u52a8\u63a7\u5236\u5ba4\u6e29\u8fbe\u6807\u4e86\u8fd8\u5728\"\u50bb\u70e7\"\uff1b\u66fc\u745e\u5fb7\u8ba9\u7cfb\u7edf\u542c\u5ba4\u6e29\u6307\u6325\uff0c\u5206\u5ba4\u6309\u9700\u4f9b\u70ed\uff0c\u592b\u59bb\u4e8c\u4eba\u53ef\u624b\u673a\u8fdc\u7a0b\u5f00\u5173\u3002<\/p>\n    <\/div>\n\n    <h3>3.3 \u8be5\u6848\u4f8b\u8282\u80fd\u578b\u65b9\u6848\u914d\u7f6e<\/h3>\n    <table>\n      <thead><tr><th>\u7cfb\u7edf\u73af\u8282<\/th><th>\u9009\u7528\u6750\u6599\/\u8bbe\u5907<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u70ed\u6e90<\/td><td><strong>\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089 25KW<\/strong><\/td><td>\u70ed\u6548\u7387108%\uff0c\u51b7\u51dd\u4f59\u70ed\u56de\u6536\uff0c5\u7ea7\u73af\u4fdd\uff0c15~20\u5e74\u5bff\u547d<\/td><\/tr>\n        <tr><td>\u4e3b\u7ba1<\/td><td><strong>\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 De25<\/strong><\/td><td>EVOH\u963b\u6c27\u5c42\uff0c\u963b\u6c27\u738799%+\uff0c5\u5c42\u590d\u5408\u7ed3\u6784<\/td><\/tr>\n        <tr><td>\u76d8\u7ba1<\/td><td>De16 \u963b\u6c27PE-RT\u5730\u6696\u76d8\u7ba1<\/td><td>\u6807\u51c6\u7ba1\u5f84\uff0c\u963b\u6c27\u9632\u8150\uff0c\u95f4\u8ddd150mm<\/td><\/tr>\n        <tr><td>\u4fdd\u6e29<\/td><td><strong>\u4f1f\u661f\u767d\u6676\u677f2cm + \u7845\u6676\u7f51<\/strong><\/td><td>\u9ad8\u5bc6\u5ea6\u6324\u5851\u677f\uff0c\u5bfc\u70ed\u7cfb\u65700.028W\/m\u00b7K\uff0c\u7845\u6676\u7f51\u52a0\u56fa\u6297\u88c2<\/td><\/tr>\n        <tr><td>\u63a7\u5236<\/td><td><strong>\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf<\/strong><\/td><td>\u5206\u5ba4\u6e29\u63a7+\u624b\u673a\u8fdc\u7a0b\uff0c\u6309\u9700\u4f9b\u70ed<\/td><\/tr>\n        <tr><td>\u4e3b\u7ba1\u5de5\u827a<\/td><td>\u5927\u5f27\u5f2f\uff08\u975e\u76f4\u89d2\u5f2f\uff09<\/td><td>\u51cf\u5c11\u6c34\u963b40%+\uff0c\u63d0\u5347\u5faa\u73af\u6548\u7387<\/td><\/tr>\n        <tr><td>\u53cd\u5c04\u819c<\/td><td>\u94dd\u7b94\u53cd\u5c04\u819c<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf\uff0c\u63d0\u5347\u70ed\u6548\u7387<\/td><\/tr>\n        <tr><td>\u65bd\u5de5\u6807\u51c6<\/td><td>\u7cbe\u5de5\u516d\u6b65\u6cd5<\/td><td>36\u9879\u8282\u70b9\u9a8c\u6536\uff0c\u5168\u7a0b\u62cd\u7167\u7559\u6863<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>3.4 \u5730\u6696\u70ed\u8d1f\u8377\u8ba1\u7b97\u8868<\/h3>\n    <table>\n      <thead><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef\uff08\u33a1\uff09<\/th><th>\u5355\u4f4d\u70ed\u8d1f\u8377\uff08W\/\u33a1\uff09<\/th><th>\u603b\u70ed\u8d1f\u8377\uff08W\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5ba2\u9910\u5385<\/td><td>31<\/td><td>100<\/td><td>3100<\/td><\/tr>\n        <tr><td>\u4e3b\u5367<\/td><td>14<\/td><td>130<\/td><td>1820<\/td><\/tr>\n        <tr><td>\u5367\u5ba4A<\/td><td>8.7<\/td><td>130<\/td><td>1131<\/td><\/tr>\n        <tr><td>\u5367\u5ba4B<\/td><td>7.2<\/td><td>130<\/td><td>936<\/td><\/tr>\n        <tr class=\"lmai-case-row-rec\"><td>\u5408\u8ba1<\/td><td>61<\/td><td>\u2014<\/td><td>6987\uff08\u7ea67.0kW\uff09<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <p style=\"font-size:13px;color:var(--text-l);margin-top:6px\">* \u70ed\u8d1f\u8377\u4f9d\u636eGB 50736-2012\uff0c\u6210\u90fd\u5730\u533a\u51ac\u5b63\u8bbe\u8ba1\u5ba4\u5916\u6e29\u5ea62\u2103\uff0c\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea620\u2103\u3002<\/p>\n\n    <h3>3.5 \u51b7\u51dd\u7089 vs \u666e\u901a\u7089\u5bf9\u6bd4\u8868<\/h3>\n    <table>\n      <thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u51b7\u51dd\u7089\uff08\u83f2\u65af\u66fcB1JG 25KW\uff09<\/th><th>\u666e\u901a\u58c1\u6302\u7089<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u70ed\u6548\u7387<\/td><td><strong>108%<\/strong><\/td><td>90%~93%<\/td><\/tr>\n        <tr><td>\u9002\u7528\u7cfb\u7edf<\/td><td>\u4f4e\u6e29\u5730\u6696\uff08\u5efa\u8bae45\u2103\u4ee5\u4e0b\uff09<\/td><td>\u6696\u6c14\u7247\/\u9ad8\u6e29\u5730\u6696<\/td><\/tr>\n        <tr><td>\u8282\u80fd\u5e45\u5ea6<\/td><td><strong>\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\u770120%~28%<\/strong><\/td><td>\u57fa\u51c6<\/td><\/tr>\n        <tr><td>\u8bbe\u8ba1\u5bff\u547d<\/td><td><strong>15~20\u5e74<\/strong><\/td><td>10~12\u5e74<\/td><\/tr>\n        <tr><td>\u566a\u97f3<\/td><td>\u226445dB<\/td><td>\u226455dB<\/td><\/tr>\n        <tr><td>\u73af\u4fdd<\/td><td>\u4f4eNOx\u6392\u653e\uff0c\u8fbe5\u7ea7\u6807\u51c6<\/td><td>3\u7ea7\u6807\u51c6<\/td><\/tr>\n        <tr><td>\u521d\u6295\u6210\u672c<\/td><td>\u8f83\u9ad8\uff08\u521d\u6295\u7565\u9ad8\uff0c\u5177\u4f53\u989d\u5ea6\u4ee5\u73b0\u573a\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\uff09<\/td><td>\u8f83\u4f4e<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>3.6 20\u5e74\u751f\u547d\u5468\u671f\u6210\u672c\u8868<\/h3>\n    <table>\n      <thead><tr><th>\u8d39\u7528\u9879\u76ee<\/th><th>\u51b7\u51dd\u7089\u65b9\u6848<\/th><th>\u666e\u901a\u7089\u65b9\u6848<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8bbe\u5907\u521d\u6295<\/td><td>\u8f83\u9ad8<\/td><td>\u8f83\u4f4e<\/td><\/tr>\n        <tr><td>\u5e74\u5747\u71c3\u6c14\u8d39<\/td><td><strong>\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\u7ea61600~2400\u5143<\/strong><\/td><td>\u7ea62400~3120\u5143<\/td><\/tr>\n        <tr><td>20\u5e74\u71c3\u6c14\u8d39\u5408\u8ba1<\/td><td>\u7ea63.2~4.8\u4e07\u5143<\/td><td>\u7ea64.8~6.24\u4e07\u5143<\/td><\/tr>\n        <tr><td>20\u5e74\u7ef4\u62a4\u8d39\u4f30\u7b97<\/td><td>\u7ea61.5~2\u4e07\u5143<\/td><td>\u7ea62.5~3.5\u4e07\u5143<\/td><\/tr>\n        <tr><td>\u8bbe\u5907\u66f4\u6362<\/td><td>\u7ea61\u6b21\uff0815~20\u5e74\uff09<\/td><td>\u7ea62\u6b21\uff08\u6bcf10~12\u5e74\uff09<\/td><\/tr>\n        <tr class=\"lmai-case-row-total\"><td>20\u5e74\u603b\u6210\u672c<\/td><td><strong>\u7ea615~17\u4e07\u5143<\/strong><\/td><td><strong>\u7ea618~20\u4e07\u5143<\/strong><\/td><\/tr>\n        <tr><td colspan=\"3\" style=\"font-size:13px;color:var(--text-l)\">\u6570\u636e\u8bf4\u660e\uff1a\u71c3\u6c14\u8d39\u4ee5\u9526\u6c5f\u7247\u533a\u540c\u6237\u578b\u5b9e\u6d4b\u6570\u636e\u4e3a\u57fa\u7840\uff0c\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u708920\u5e74\u8282\u7701\u7ea63\u4e07\u5143\uff08\u533a\u95f4\u7ea62~4\u4e07\u5143\uff09\u3002<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>3.7 \u900f\u660e\u62a5\u4ef7\uff08\u54c1\u8d28\u578b\uff09+ \u6570\u636e\u53ef\u89c6\u5316<\/h3>\n    <div class=\"lmai-case-card lmai-case-card-brand\">\n      <p style=\"margin-bottom:8px\"><strong>\ud83d\udccb \u54c1\u8d28\u5012\u63a8\u6e05\u5355<\/strong>\uff1a\u5ba2\u6237\u786c\u7ea6\u675f\u2014\u2014\u8f85\u6750\u5168\u77e5\u540d\u54c1\u724c\u3001\u540e\u671f\u8282\u80fd\u3002\u914d\u7f6e\u4ee5\u6b64\u5012\u63a8\uff1a\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u708925KW + \u4f1f\u661f5\u5c42\u963b\u6c27\u4e3b\u7ba1 + De16\u963b\u6c27\u76d8\u7ba1 + \u4f1f\u661f\u767d\u6676\u677f+\u7845\u6676\u7f51 + \u66fc\u745e\u5fb7\u5206\u63a7 + \u5927\u5f27\u5f2f\u5de5\u827a + \u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3002<\/p>\n      <p style=\"font-size:14px;color:var(--text-l)\"><strong>\ud83d\udcca \u65b9\u6848\u5bf9\u6bd4\uff0861\u33a1\u5730\u6696\u542b\u9505\u7089\uff09<\/strong>\uff1a\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b8c\u6574\u65b9\u6848\u533a\u95f4\u542b\u8bbe\u5907+\u5168\u5957\u65bd\u5de5\u3002\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u65b9\u6848\u521d\u6295\u7565\u9ad8\u4e8e\u666e\u901a\u7089\uff0c\u4f4620\u5e74\u603b\u6210\u672c\u663e\u8457\u66f4\u4f4e\u3002\u7cbe\u51c6\u4ef7\u683c\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u786e\u5b9a\u7684\u91c7\u6696\u9762\u79ef\u3001\u56de\u8def\u6570\u4e3a\u51c6\u3002<\/p>\n    <\/div>\n    <div class=\"lmai-case-chart-box\" style=\"max-width:560px;margin:16px auto 0\">\n      <h4>20\u5e74\u603b\u6210\u672c\u5bf9\u6bd4\uff08\u51b7\u51dd\u7089 vs \u666e\u901a\u7089\uff0c\u53d6\u533a\u95f4\u4e2d\u503c\uff09<\/h4>\n      <div style=\"display:flex;flex-direction:column;gap:12px;margin:14px 0\">\n        <div><div style=\"font-size:13px;margin-bottom:4px\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u65b9\u6848<\/div><div style=\"background:#0D7C7F;border-radius:6px;height:22px;width:74%\"><\/div><\/div>\n        <div><div style=\"font-size:13px;margin-bottom:4px\">\u666e\u901a\u58c1\u6302\u7089\u65b9\u6848<\/div><div style=\"background:#9ec9cb;border-radius:6px;height:22px;width:100%\"><\/div><\/div>\n      <\/div>\n      <p class=\"lmai-case-chart-note\">\u53d6\u533a\u95f4\u4e2d\u503c\uff1a\u51b7\u51dd\u7089\u7ea616\u4e07\u3001\u666e\u901a\u7089\u7ea619\u4e07\uff1b\u672c\u5c0f\u533a\u5b9e\u6d4b\u51b7\u51dd\u708920\u5e74\u53ef\u7701\u7ea63\u4e07\u5143\u3002<\/p>\n    <\/div>\n\n    <h3>\u5ef6\u4f38\u4e86\u89e3 \u00b7 \u672c\u6848\u6838\u5fc3\u914d\u7f6e<\/h3>\n    <div class=\"lmai-case-link-grid\">\n      <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2553\" target=\"_blank\" rel=\"noopener\">\n        <span class=\"lmai-case-lc-t\">\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\u8be6\u60c5<\/span>\n        <span class=\"lmai-case-lc-d\">\u672c\u6848\u70ed\u6e90\uff0c\u70ed\u6548\u7387108%\u6280\u672f\u89e3\u6790 \u2192<\/span>\n      <\/a>\n      <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" rel=\"noopener\">\n        <span class=\"lmai-case-lc-t\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u9009\u578b<\/span>\n        <span class=\"lmai-case-lc-d\">\u51b7\u51dd\u7089vs\u666e\u901a\u7089\u00b7\u5168\u7cfb\u5217\u9009\u578b \u2192<\/span>\n      <\/a>\n      <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\" rel=\"noopener\">\n        <span class=\"lmai-case-lc-t\">\u7cbe\u5de5\u516d\u6b65\u6cd5\u5b89\u88c5\u6807\u51c6<\/span>\n        <span class=\"lmai-case-lc-d\">\u672c\u6848\u65bd\u5de5\u6807\u51c6\uff0c36\u9879\u8282\u70b9\u9a8c\u6536 \u2192<\/span>\n      <\/a>\n    <\/div>\n\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"s4\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">S4<\/span>\n    <h2>\u65bd\u5de5\u4ea4\u4ed8\u548c\u4fdd\u969c<\/h2>\n    <div class=\"lmai-case-s-lead\">\u9f99\u8109\u6696\u901a\u81ea\u517b\u5b89\u88c5\u5de5\uff0c\u975e\u5916\u5305\u3002\u6bcf\u9053\u5de5\u5e8f\u6709\u6807\u51c6\u3001\u6709\u9a8c\u6536\u3001\u6709\u7167\u7247\u8bb0\u5f55\u2014\u2014\u51b7\u51dd\u7089+\u4e00\u7ebf\u8f85\u6750\u7cfb\u7edf\u5bf9\u65bd\u5de5\u7cbe\u5ea6\u8981\u6c42\u66f4\u9ad8\u3002<\/div>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n\n    <h3>4.1 \u7cbe\u5de5\u5b89\u88c5\u6807\u51c6<\/h3>\n    <div class=\"lmai-case-card lmai-case-card-brand\">\n      <p style=\"font-weight:600;color:var(--brand)\">\u9f99\u8109\u6696\u901a \u2014 \u81ea\u517b\u5b89\u88c5\u5de5\uff0c\u975e\u5916\u5305<\/p>\n      <ul style=\"margin-top:8px\">\n        <li>\u70ed\u6e90\uff1a\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089<\/li>\n        <li>\u4e3b\u7ba1\uff1a\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1 De25\uff08\u5927\u5f27\u5f2f\u5de5\u827a\uff09<\/li>\n        <li>\u76d8\u7ba1\uff1aDe16\u963b\u6c27PE-RT\uff08\u95f4\u8ddd150mm\uff09<\/li>\n        <li>\u4fdd\u6e29\u677f\uff1a\u4f1f\u661f\u767d\u6676\u677f 2cm<\/li>\n        <li>\u52a0\u56fa\uff1a\u7845\u6676\u7f51 + \u94dd\u7b94\u53cd\u5c04\u819c<\/li>\n        <li>\u63a7\u5236\uff1a\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\u7cfb\u7edf<\/li>\n        <li>\u56de\u586b\uff1aC20\u7ec6\u77f3\u6df7\u51dd\u571f + \u6297\u88c2\u7ea4\u7ef4<\/li>\n        <li>\u9a8c\u6536\uff1a0.8MPa\/24h\u4fdd\u538b<\/li>\n      <\/ul>\n    <\/div>\n\n    <h3>4.2 \u65bd\u5de5\u5de5\u5e8f\uff08\u516d\u6b65\u7cbe\u5de5\u6cd5\uff09<\/h3>\n    <table>\n      <thead><tr><th>\u5de5\u5e8f<\/th><th>\u5185\u5bb9<\/th><th>\u9a8c\u6536\u6807\u51c6<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u2460 \u73b0\u573a\u52d8\u6d4b\u00b7\u5b9a\u4f4d\u653e\u6837<\/td><td>\u786e\u8ba4\u91c7\u6696\u533a\u57df61\u33a1\u3001\u89c4\u52125\u56de\u8def\uff08\u5ba2\u9910\u53852\u8def\u3001\u4e3b\u5367\/\u5367\u5ba4A\/\u5367\u5ba4B\u54041\u8def\uff09\u3001\u6807\u8bb0\u76d8\u7ba1\u95f4\u8ddd150mm<\/td><td>\u9762\u79ef\/\u56de\u8def\/\u95f4\u8ddd\u786e\u8ba4<\/td><\/tr>\n        <tr><td>\u2461 \u4e3b\u7ba1\u94fa\u8bbe\u00b7\u5927\u5f27\u5f2f<\/td><td>\u4f1f\u661f5\u5c42\u963b\u6c27De25\u4e3b\u7ba1\u3001\u5927\u5f27\u5f2f\u5de5\u827a\u3001\u5168\u7a0b\u4fdd\u6e29\u5305\u88f9<\/td><td>\u963b\u6c27\u738799%+\u3001\u6c34\u963b\u964d40%+<\/td><\/tr>\n        <tr><td>\u2462 \u767d\u6676\u677f\u00b7\u53cd\u5c04\u819c\u00b7\u7845\u6676\u7f51<\/td><td>2cm\u767d\u6676\u677f + \u94dd\u7b94\u53cd\u5c04\u819c + \u7845\u6676\u7f51\u52a0\u56fa<\/td><td>\u677f\u7f1d\u4e25\u5bc6\u3001\u642d\u63a5\u5230\u4f4d<\/td><\/tr>\n        <tr><td>\u2463 \u76d8\u7ba1\u94fa\u8bbe\u00b7\u627e\u5e73<\/td><td>De16\u963b\u6c27\u76d8\u7ba1\u95f4\u8ddd150mm\u3001C20\u7ec6\u77f3\u6df7\u51dd\u571f+\u6297\u88c2\u7ea4\u7ef4\u56de\u586b<\/td><td>\u95f4\u8ddd150mm\u3001\u517b\u62a47\u5929<\/td><\/tr>\n        <tr><td>\u2464 \u5206\u96c6\u6c34\u5668\u00b7\u4fdd\u538b<\/td><td>\u66fc\u745e\u5fb7\u5206\u96c6\u6c34\u5668\u30010.8MPa\/24h\u4fdd\u538b\u6d4b\u8bd5<\/td><td>\u538b\u964d\u22640.02MPa\u3001\u65e0\u6cc4\u6f0f<\/td><\/tr>\n        <tr><td>\u2465 \u9505\u7089\u5b89\u88c5\u00b7\u8c03\u8bd5\u4ea4\u4ed8<\/td><td>\u83f2\u65af\u66fcB1JG\u5b89\u88c5\u3001\u7cfb\u7edf\u8054\u52a8\u8c03\u8bd5\u3001\u4ea4\u4ed8\u6559\u5b66<\/td><td>\u51fa\u5177\u9a8c\u6536\u62a5\u544a<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>4.3 \u65bd\u5de5\u5b9e\u666f\u56fe\u96c6<\/h3>\n    <p style=\"font-size:13px;color:var(--text-l)\">\u4ee5\u4e0b\u6309\u9f99\u8109\u300a\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303\u300b\u5f52\u6863\u672c\u6848\u4f8b\u65bd\u5de5\u5b9e\u666f\uff0c\u6309\u300c\u8bbe\u8ba1\u2192\u65bd\u5de5\u2192\u5b89\u88c5\u300d\u4e09\u9636\u6bb5\u6392\u5217\u3002<\/p>\n\n    <h4 style=\"color:var(--brand);font-size:15px;margin:18px 0 8px;padding-bottom:4px;border-bottom:2px solid var(--border)\">\u8bbe\u8ba1<\/h4>\n    <div class=\"lmai-case-chart-grid\" style=\"grid-template-columns:repeat(2,1fr);max-width:560px;margin:0 auto\">\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu01.jpg\" alt=\"\u8bbe\u8ba1\u5e73\u9762\u56fe\uff08\u4e00\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u8bbe\u8ba1\u5e73\u9762\u56fe\uff08\u4e00\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu02.jpg\" alt=\"\u8bbe\u8ba1\u5e73\u9762\u56fe\uff08\u4e8c\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u8bbe\u8ba1\u5e73\u9762\u56fe\uff08\u4e8c\uff09<\/div><\/div>\n    <\/div>\n\n    <h4 style=\"color:var(--brand);font-size:15px;margin:18px 0 8px;padding-bottom:4px;border-bottom:2px solid var(--border)\">\u65bd\u5de5<\/h4>\n    <div class=\"lmai-case-chart-grid\" style=\"grid-template-columns:repeat(4,1fr);max-width:1120px;margin:0 auto\">\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanpanguanshigong01.jpg\" alt=\"\u76d8\u7ba1\u65bd\u5de5\uff08\u4e00\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u76d8\u7ba1\u65bd\u5de5\uff08\u4e00\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanpanguanshigong02.jpg\" alt=\"\u76d8\u7ba1\u65bd\u5de5\uff08\u4e8c\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u76d8\u7ba1\u65bd\u5de5\uff08\u4e8c\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanpanguanshigong03.jpg\" alt=\"\u76d8\u7ba1\u65bd\u5de5\uff08\u4e09\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u76d8\u7ba1\u65bd\u5de5\uff08\u4e09\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanpanguanshigong04.jpg\" alt=\"\u76d8\u7ba1\u65bd\u5de5\uff08\u56db\uff09\" loading=\"lazy\" style=\"aspect-ratio:3\/4;object-fit:cover\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u76d8\u7ba1\u65bd\u5de5\uff08\u56db\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanpanguanshigong05.jpg\" alt=\"\u76d8\u7ba1\u65bd\u5de5\uff08\u4e94\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u76d8\u7ba1\u65bd\u5de5\uff08\u4e94\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanhuituanshigong01.jpg\" alt=\"\u56de\u586b\u65bd\u5de5\uff08\u4e00\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u56de\u586b\u65bd\u5de5\uff08\u4e00\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanhuituanshigong02.jpg\" alt=\"\u56de\u586b\u65bd\u5de5\uff08\u4e8c\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u56de\u586b\u65bd\u5de5\uff08\u4e8c\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanhuituanshigong03.jpg\" alt=\"\u56de\u586b\u65bd\u5de5\uff08\u4e09\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u56de\u586b\u65bd\u5de5\uff08\u4e09\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanfenjishuigianzhuang01.jpg\" alt=\"\u5206\u96c6\u6c34\u5668\u5b89\u88c5\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u5206\u96c6\u6c34\u5668\u5b89\u88c5<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuandayaceshi01.jpg\" alt=\"\u6253\u538b\u6d4b\u8bd5\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u6253\u538b\u6d4b\u8bd5<\/div><\/div>\n    <\/div>\n\n    <h4 style=\"color:var(--brand);font-size:15px;margin:18px 0 8px;padding-bottom:4px;border-bottom:2px solid var(--border)\">\u5b89\u88c5<\/h4>\n    <div class=\"lmai-case-chart-grid\" style=\"grid-template-columns:repeat(3,1fr);max-width:720px;margin:0 auto\">\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanxiankongqianzhuang01.jpg\" alt=\"\u7ebf\u63a7\u5668\u5b89\u88c5\uff08\u4e00\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u7ebf\u63a7\u5668\u5b89\u88c5\uff08\u4e00\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-dinuanxiankongqianzhuang02.jpg\" alt=\"\u7ebf\u63a7\u5668\u5b89\u88c5\uff08\u4e8c\uff09\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u5730\u6696\u7ebf\u63a7\u5668\u5b89\u88c5\uff08\u4e8c\uff09<\/div><\/div>\n      <div class=\"lmai-case-chart-cell\"><figure class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-bigualuanzhuang01.jpg\" alt=\"\u58c1\u6302\u7089\u5b89\u88c5\" loading=\"lazy\"><\/figure><div class=\"lmai-case-photo-desc\">\u58c1\u6302\u7089\u5b89\u88c5<\/div><\/div>\n    <\/div>\n\n    <h3>4.4 \u670d\u52a1\u627f\u8bfa<\/h3>\n    <div class=\"lmai-case-card lmai-case-card-success\">\n      <ul>\n        <li><strong>\u81ea\u517b\u5de5\u5b89\u88c5<\/strong>\uff1a\u975e\u5916\u5305\uff0c\u6bcf\u9053\u5de5\u5e8f\u6709\u6807\u51c6\u3001\u6709\u9a8c\u6536\u3001\u6709\u7167\u7247\u8bb0\u5f55<\/li>\n        <li><strong>10\u5e74\u8ddf\u8e2a<\/strong>\uff1a\u7b2c1\/3\/5\/10\u5e74\u56db\u4efd\u62a5\u544a\uff0c\u6570\u636e\u8bf4\u8bdd\uff0c\u4e0d\u7a7a\u53e3\u627f\u8bfa<\/li>\n        <li><strong>\u4e13\u5c5e\u670d\u52a1<\/strong>\uff1a\u7cfb\u7edf\u5ef6\u4fdd\u3001\u514d\u8d39\u4e0a\u95e8\u4e0d\u9650\u6b21<\/li>\n        \n        <li><strong>\u900f\u660e\u62a5\u4ef7<\/strong>\uff1a\u8bbe\u5907\/\u5b89\u88c5\/\u8f85\u6750\u5206\u5217\uff0c\u65e0\u9690\u85cf\u8d39\u7528<\/li>\n        <li><strong>\u4e0d\u8d2c\u4f4e\u7ade\u54c1<\/strong>\uff1a\u683c\u529b\/\u7f8e\u7684\u90fd\u662f\u597d\u54c1\u724c\uff0c\u6211\u4eec\u53ea\u8bf4\u5dee\u5f02<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lmai-case-trust-box\" style=\"margin-top:16px\">\n      <h4>\u5ba2\u6237\u76ee\u6807<\/h4>\n      <p>\u4e3a\u5ba2\u6237\u4ea4\u4ed8\u4e00\u5957<strong>\u8282\u80fd\u3001\u5b89\u9759\u3001\u8212\u9002<\/strong>\u7684\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf\u3002\u5177\u4f53\u76ee\u6807\uff1a<\/p>\n      <ul style=\"margin-top:8px\">\n        <li>\u51ac\u5b63\u6052\u6e29\u8212\u9002\uff0c\u5206\u5ba4\u63a7\u6e29\uff0c\u6309\u9700\u5f00\u5173<\/li>\n        <li>\u672c\u5c0f\u533a\u5b9e\u6d4b\u6708\u71c3\u6c14\u8d39400~600\u5143\uff08\u51ac\u5b63\u5168\u5f00\uff09\uff0c\u6bd4\u666e\u901a\u7089\u770120%~28%<\/li>\n        <li>\u4f1f\u661f5\u5c42\u963b\u6c27+0.8MPa\u4fdd\u538b\uff0c\u7cfb\u7edf\u53ef\u9760\u3001\u5bff\u547d\u957f<\/li>\n        <li>\u5de5\u827a\u900f\u660e\uff0c\u5173\u952e\u8282\u70b9\u4e09\u65b9\u9a8c\u6536\u3001\u5168\u7a0b\u62cd\u7167\u7559\u6863<\/li>\n      <\/ul>\n    <\/div>\n\n    <h3>4.5 \u6388\u6743\u8bc1\u4e66<\/h3>\n    <div class=\"lmai-case-license-gallery\">\n      <div class=\"lmai-case-license-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546\u8bc1\u4e66\" loading=\"lazy\">\n        <span>\u9f99\u8109\u6696\u901a\u00b7\u6388\u6743\u7ecf\u9500\u5546\u8bc1\u4e66<\/span>\n      <\/div>\n      <div class=\"lmai-case-license-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-gold.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u91d1\u724c\u670d\u52a1\u5546\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\">\n        <span>\u9f99\u8109\u6696\u901a\u00b7\u91d1\u724c\u670d\u52a1\u5546<\/span>\n      <\/div>\n      <div class=\"lmai-case-license-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-water.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6c34\u7cfb\u7edf\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\">\n        <span>\u9f99\u8109\u6696\u901a\u00b7\u6c34\u7cfb\u7edf\u6388\u6743<\/span>\n      <\/div>\n      <div class=\"lmai-case-license-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\">\n        <span>\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5<\/span>\n      <\/div>\n      <div class=\"lmai-case-license-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\">\n        <span>\u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5<\/span>\n      <\/div>\n    <\/div>\n\n    <h3>4.6 \u6388\u6743\u95e8\u5e97\u4e0e\u670d\u52a1\u4fdd\u969c<\/h3>\n    <div class=\"lmai-case-stores\">\n      <div class=\"lmai-case-store\">\n        <img decoding=\"async\" class=\"lmai-case-store-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\u5b9e\u666f\" loading=\"lazy\">\n        <b>\u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/b>\n        <span>\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/span>\n        <span>\u7535\u8bdd 028-86131795<\/span>\n      <\/div>\n      <div class=\"lmai-case-store\">\n        <img decoding=\"async\" class=\"lmai-case-store-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\u5b9e\u666f\" loading=\"lazy\">\n        <b>\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/b>\n        <span>\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/span>\n        <span>\u7535\u8bdd 028-65272586<\/span>\n      <\/div>\n    <\/div>\n    <div class=\"lmai-case-card lmai-case-card-success\" style=\"margin-top:8px\">\n      <p style=\"font-size:13px\">\ud83d\udee1\ufe0f <strong>\u670d\u52a1\u4fdd\u969c<\/strong>\uff1a\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u4e3b\u673a\u8d28\u4fdd + \u7cfb\u7edf\u8d28\u4fdd + \u957f\u671f\u7ef4\u62a4\uff0c\u540c\u57ce24\u5c0f\u65f6\u4e0a\u95e8\u54cd\u5e94\uff1b\u65bd\u5de5\u5168\u7a0b\u62cd\u7167\u53d1\u7fa4\u3001\u5173\u952e\u8282\u70b9\u4e09\u65b9\u9a8c\u6536\uff0c\u8fc7\u7a0b\u900f\u660e\u53ef\u8ffd\u6eaf\u3002\u7531\u5357\/\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\u652f\u6491\u3002<\/p>\n    <\/div>\n    <p style=\"text-align:center;margin-top:20px;font-size:15px;color:var(--brand);font-weight:600\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"s5\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">S5<\/span>\n    <h2>\u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/h2>\n    <div class=\"lmai-case-s-lead\">\u516d\u7ef4\u5ea6\u8bc4\u4f30\u4ea4\u4ed8\u6548\u679c\u300110\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u5151\u73b0\u627f\u8bfa\u3001AI\u9a8c\u8bc1\u6e05\u5355\u7ecf\u5f97\u8d77\u67e5\u2014\u2014\u95ed\u73af\u6536\u5c3e\u3002<\/div>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n\n    <h3>5.1 \u516d\u7ef4\u5ea6\u8bc4\u4f30<\/h3>\n    <table>\n      <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u51b7\u51dd\u7089\u5730\u6696<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u521d\u6295\u8d44<\/td><td><span class=\"lmai-case-badge lmai-case-b-orange\">\u2605\u2605\u2605<\/span><\/td><td>\u542b\u9505\u7089+\u8f85\u6750+\u65bd\u5de5\uff0c\u54c1\u8d28\u578b\u7565\u9ad8<\/td><\/tr>\n        <tr><td>\u8fd0\u884c\u8d39<\/td><td><span class=\"lmai-case-badge lmai-case-b-green\">\u2605\u2605\u2605\u2605\u2605 \u770120%~28%<\/span><\/td><td>\u672c\u5c0f\u533a\u5b9e\u6d4b\u6708\u5747400~600\u5143<\/td><\/tr>\n        <tr><td>\u8212\u9002\u5ea6<\/td><td><span class=\"lmai-case-badge lmai-case-b-gold\">\u2605\u2605\u2605\u2605\u2605 \u6052\u6e29\u5206\u63a7<\/span><\/td><td>\u5730\u6696\u6052\u6e29\u3001\u5206\u5ba4\u63a7\u6e29<\/td><\/tr>\n        <tr><td>\u7a33\u5b9a\u6027<\/td><td><span class=\"lmai-case-badge lmai-case-b-green\">\u2605\u2605\u2605\u2605 \u53ef\u9760<\/span><\/td><td>\u4f1f\u661f\u963b\u6c27\u7ba1+0.8MPa\u4fdd\u538b<\/td><\/tr>\n        <tr><td>\u7ef4\u62a4\u8d39<\/td><td><span class=\"lmai-case-badge lmai-case-b-green\">\u2605\u2605\u2605\u2605 \u8f83\u4f4e<\/span><\/td><td>\u51b7\u51dd\u7089\u4fdd\u517b\u7b80\u5355\uff0c\u4e00\u7ebf\u8f85\u6750\u5bff\u547d\u957f<\/td><\/tr>\n        <tr><td>\u5bff\u547d<\/td><td><span class=\"lmai-case-badge lmai-case-b-green\">\u2605\u2605\u2605\u2605\u2605 15~20\u5e74<\/span><\/td><td>\u51b7\u51dd\u7089\u8bbe\u8ba1\u5bff\u547d\u957f\uff0c\u963b\u6c27\u7ba1\u5ef6\u957f\u7cfb\u7edf\u5bff\u547d<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"lmai-case-chart-box\" style=\"max-width:560px;margin:16px auto 0\">\n      <h4>\u516d\u7ef4\u5ea6\u7efc\u5408\u8bc4\u5206\uff08\u6ee1\u52065\u661f\uff09<\/h4>\n      <ul style=\"list-style:none;padding:0;margin:14px 0;font-size:14px;line-height:2.1\">\n        <li>\u521d\u6295\u8d44\uff1a\u2605\u2605\u2605\u2606\u2606<\/li>\n        <li>\u8fd0\u884c\u8d39\uff1a\u2605\u2605\u2605\u2605\u2605<\/li>\n        <li>\u8212\u9002\u5ea6\uff1a\u2605\u2605\u2605\u2605\u2605<\/li>\n        <li>\u7a33\u5b9a\u6027\uff1a\u2605\u2605\u2605\u2605\u2606<\/li>\n        <li>\u7ef4\u62a4\u8d39\uff1a\u2605\u2605\u2605\u2605\u2606<\/li>\n        <li>\u5bff\u547d\uff1a\u2605\u2605\u2605\u2605\u2605<\/li>\n      <\/ul>\n      <p class=\"lmai-case-chart-note\">\u521d\u6295\u8d44\u2605\u2605\u2605\u4e3a\u76f8\u5bf9\u660e\u663e\u7684\u6263\u5206\u9879\uff0c\u8fd0\u884c\u8d39\/\u8212\u9002\u5ea6\/\u5bff\u547d\u5747\u8fbe\u4e94\u661f\u3002<\/p>\n    <\/div>\n\n    <h3>5.2 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/h3>\n    <table>\n      <thead><tr><th>\u9636\u6bb5<\/th><th>\u65f6\u95f4<\/th><th>\u4ea4\u4ed8\u7269<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u57fa\u51c6\u5efa\u7acb\u671f<\/td><td>\u7b2c1\u5e74<\/td><td>\u300a\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848\u300b\u5b89\u88c5\u540e\u5b9e\u6d4b\u5404\u623f\u95f4\u6e29\u5ea6\/\u80fd\u8017\/\u5347\u6e29\u66f2\u7ebf<\/td><\/tr>\n        <tr><td>\u6548\u679c\u9a8c\u8bc1\u671f<\/td><td>\u7b2c3\u5e74<\/td><td>\u300a3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a\u300b\u5bf9\u6bd4\u71c3\u6c14\u6570\u636e\u9a8c\u8bc1\u8282\u80fd\u6548\u679c<\/td><\/tr>\n        <tr><td>\u6df1\u5ea6\u89e3\u6790\u671f<\/td><td>\u7b2c5\u5e74<\/td><td>\u300a\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\u300b\u68c0\u6d4b\u9505\u7089\/\u7ba1\u8def\u8fd0\u884c\u72b6\u6001<\/td><\/tr>\n        <tr><td>\u627f\u8bfa\u5151\u73b0\u671f<\/td><td>\u7b2c10\u5e74<\/td><td>\u300a10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u300b\u603b\u8d26\u5151\u73b0<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3>5.3 AI\u9a8c\u8bc1\u6e05\u5355<\/h3>\n    <table>\n      <thead><tr><th>\u9a8c\u8bc1\u9879<\/th><th>\u9a8c\u8bc1\u65b9\u6cd5<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8bca\u65ad\u51c6\u786e\u6027<\/td><td>\u5c06S2\u8bca\u65ad\u7ed3\u8bba\u53d1\u7ed9AI\uff1a\"\u9f99\u8109\u6696\u901a\u5bf9\u6211\u7684\u9700\u6c42\u7406\u89e3\u5f97\u5bf9\u5417\uff1f\"<\/td><\/tr>\n        <tr><td>\u51b7\u51dd\u7089\u9009\u578b<\/td><td>\u53d1\u7ed9AI\uff1a\"61\u33a1\u914d25KW\u83f2\u65af\u66fcB1JG\u662f\u5426\u5408\u7406\uff1f\"<\/td><\/tr>\n        <tr><td>\u963b\u6c27\u7ba1\u539f\u7406<\/td><td>\u53d1\u7ed9AI\uff1a\"\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1\u963b\u6c27\u738799%\u662f\u771f\u7684\u5417\uff1f\"<\/td><\/tr>\n        <tr><td>\u62a5\u4ef7\u900f\u660e\u5ea6<\/td><td>\u5c06\u914d\u7f6e\u6e05\u5355\u53d1\u7ed9AI\uff1a\"\u8fd9\u4e2a\u62a5\u4ef7\u6709\u9690\u85cf\u8d39\u7528\u5417\uff1f\"<\/td><\/tr>\n        <tr><td>20\u5e74\u603b\u8d26<\/td><td>\u5c06\u8ba1\u7b97\u8fc7\u7a0b\u548c\u53c2\u6570\u53d1\u7ed9AI\u9a8c\u8bc1<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"lmai-case-card lmai-case-card-brand\" style=\"margin-top:14px\">\n      <p style=\"font-size:14px\"><strong>\ud83d\udd04 \u6c89\u6dc0<\/strong>\uff1a\u672c\u6848\u9a8c\u8bc1\u4e86\"\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u63a7\"\u5728\u6ce8\u91cd\u54c1\u8d28\u4e0e\u8282\u80fd\u7684\u5957\u4e09\u5e73\u5c42\u573a\u666f\u4e0b\u7684\u53ef\u843d\u5730\u6027\u2014\u2014\u70ed\u8d1f\u8377\u6838\u7b97\u53e3\u5f84\u3001\u56db\u91cd\u8282\u80fd\u9009\u578b\u903b\u8f91\u300120\u5e74\u603b\u8d26\u8ba1\u7b97\u6a21\u578b\uff0c\u90fd\u4f1a\u6c89\u6dc0\u8fdb\u9f99\u8109\u6807\u51c6\u65b9\u6848\uff0c\u8fc1\u79fb\u5230\u66f4\u591a\u540c\u7c7b\u5ba2\u6237\u3002<\/p>\n    <\/div>\n\n    <h3>5.4 \u5ba2\u6237\u6c9f\u901a\u786e\u8ba4<\/h3>\n    <div class=\"lmai-case-card lmai-case-card-gold\">\n      <ul style=\"font-size:13.5px\">\n        <li>\u2705 \u8ba4\u53ef\"\u8f85\u6750\u5168\u77e5\u540d\u54c1\u724c\"\u7684\u786c\u7ea6\u675f\uff0c\u4e3b\u52a8\u9009\u62e9\u4f1f\u661f+\u66fc\u745e\u5fb7\u4e00\u7ebf\u65b9\u6848\uff1b<\/li>\n        <li>\u2705 \u8ba4\u540c\u51b7\u51dd\u7089+\u56db\u91cd\u8282\u80fd\u7684\u9009\u578b\u903b\u8f91\uff0c\u63a5\u53d7\u4ee520\u5e74\u603b\u8d26\u8861\u91cf\u957f\u671f\u6027\u4ef7\u6bd4\uff1b<\/li>\n        <li>\u2705 \u63a5\u53d7\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u6807\u51c6\u4e0e0.8MPa\/24h\u4fdd\u538b\u9a8c\u6536\uff1b<\/li>\n        <li>\u2705 \u65bd\u5de5\u5b9e\u666f\u56fe\u96c6\u5df2\u5f52\u6863\uff08\u8bbe\u8ba12\u5f20 \u2192 \u65bd\u5de510\u5f20\uff1a\u76d8\u7ba15+\u56de\u586b3+\u5206\u96c6\u6c34\u5668+\u6253\u538b \u2192 \u5b89\u88c53\u5f20\uff1a\u7ebf\u63a7\u56682+\u58c1\u6302\u7089\uff09\uff0c\u6309\u300c\u8bbe\u8ba1\u2192\u65bd\u5de5\u2192\u5b89\u88c5\u300d\u4e09\u9636\u6bb5\u6392\u5217\uff0c\u89c1 4.3 \u65bd\u5de5\u5b9e\u666f\u56fe\u96c6\u3002<\/li>\n      <\/ul>\n    <\/div>\n\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"faq\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">FAQ<\/span>\n    <h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n    <div class=\"lmai-case-faq-item\">\n      <div class=\"lmai-case-faq-q\">61\u33a1\u5730\u6696\u914d25KW\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u591f\u7528\u5417\uff1f<\/div>\n      <div class=\"lmai-case-faq-a\">\u8db3\u591f\u300261\u33a1\u91c7\u6696\u9762\u79ef\u70ed\u8d1f\u8377\u7ea67.0kW\uff0c\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u708925KW\u989d\u5b9a\u8f93\u51fa\u8fdc\u8d85\u9700\u6c42\u3002\u51b7\u51dd\u7089\u5728\u4f4e\u8d1f\u8377\u8fd0\u884c\u65f6\u51b7\u51dd\u6548\u7387\u66f4\u9ad8\uff0c25KW\u914d\u540861\u33a1\u5c5e\u4e8e\u5408\u7406\u914d\u7f6e\uff0c\u65e2\u6ee1\u8db3\u91c7\u6696\u9700\u6c42\u53c8\u517c\u987e\u751f\u6d3b\u70ed\u6c34\u5236\u5907\u3002<\/div>\n    <\/div>\n    <div class=\"lmai-case-faq-item\">\n      <div class=\"lmai-case-faq-q\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e00\u5e74\u71c3\u6c14\u8d39\u591a\u5c11\uff1f<\/div>\n      <div class=\"lmai-case-faq-a\">\u672c\u5c0f\u533a\u540c\u6237\u578b\u5b9e\u6d4b\uff0c61\u33a1\u51ac\u5b63\u5168\u5f00\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400~600\u5143\uff0c\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u770120%~28%\u3002\u6309\u91c7\u6696\u5b634\u4e2a\u6708\u8ba1\u7b97\uff0c\u5e74\u5747\u71c3\u6c14\u8d39\u7ea61600~2400\u5143\u3002\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\u53ef\u8fdb\u4e00\u6b65\u964d\u4f4e10%~15%\u8fd0\u884c\u6210\u672c\u3002<\/div>\n    <\/div>\n    <div class=\"lmai-case-faq-item\">\n      <div class=\"lmai-case-faq-q\">\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f<\/div>\n      <div class=\"lmai-case-faq-a\">\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1\u91c7\u7528EVOH\u963b\u6c27\u5c42\uff0c5\u5c42\u5171\u6324\u590d\u5408\u7ed3\u6784\uff0c\u963b\u6c27\u738799%+\uff0c\u9632\u6b62\u6c27\u6c14\u6e17\u5165\u6c34\u7cfb\u7edf\u8150\u8680\u91d1\u5c5e\u90e8\u4ef6\uff0c\u5ef6\u957f\u7cfb\u7edf\u6574\u4f53\u5bff\u547d\u3002<\/div>\n    <\/div>\n    <div class=\"lmai-case-faq-item\">\n      <div class=\"lmai-case-faq-q\">\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\u503c\u4e0d\u503c\u5f97\u88c5\uff1f<\/div>\n      <div class=\"lmai-case-faq-a\">\u66fc\u745e\u5fb7\u5206\u63a7\u7cfb\u7edf\u652f\u6301\u5206\u5ba4\u6e29\u63a7+\u624b\u673a\u8fdc\u7a0b\uff0c\u5e38\u4f4f2\u4eba\u53ef\u6309\u9700\u5f00\u5173\u2014\u2014\u767d\u5929\u53ea\u5f00\u5ba2\u5385\u3001\u665a\u4e0a\u53ea\u5f00\u5367\u5ba4\uff0c\u907f\u514d\u7a7a\u623f\u65e0\u6548\u8017\u80fd\u3002\u6295\u5165\u7ea62000~3000\u5143\uff0c\u901a\u5e381~2\u5e74\u901a\u8fc7\u8282\u7701\u71c3\u6c14\u8d39\u56de\u6536\u3002<\/div>\n    <\/div>\n    <div class=\"lmai-case-faq-item\">\n      <div class=\"lmai-case-faq-q\">\u767d\u6676\u677f\u548c\u7845\u6676\u7f51\u6709\u4ec0\u4e48\u7528\uff1f<\/div>\n      <div class=\"lmai-case-faq-a\">\u767d\u6676\u677f\u662f\u9ad8\u5bc6\u5ea6\u6324\u5851\u4fdd\u6e29\u677f\uff0c\u5bfc\u70ed\u7cfb\u6570\u4f4e\u81f30.028W\/m\u00b7K\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931\u7ea615%~20%\uff0c\u8ba9\u66f4\u591a\u70ed\u91cf\u5411\u4e0a\u4f20\u5bfc\u81f3\u5730\u9762\u3002\u7845\u6676\u7f51\u7528\u4e8e\u52a0\u56fa\u56de\u586b\u5c42\uff0c\u9632\u6b62\u6df7\u51dd\u571f\u5f00\u88c2\u3002<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-s-section\" id=\"related\">\n  <div class=\"lmai-case-s-head\">\n    <span class=\"lmai-case-s-num\">MORE<\/span>\n    <h2>\u76f8\u5173\u6848\u4f8b<\/h2>\n    <div class=\"lmai-case-s-lead\">\u540c\u7c7b\u7cfb\u7edf\u3001\u540c\u7c7b\u9700\u6c42\uff0c\u770b\u770b\u5176\u4ed6\u5ba2\u6237\u600e\u4e48\u9009\u7684\u3002<\/div>\n  <\/div>\n  <div class=\"lmai-case-s-body\">\n    <div class=\"lmai-case-related-cases\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2977\" target=\"_blank\" class=\"lmai-case-rel-case\">\n        <span class=\"lmai-case-rc-tag\">\u542b\u5730\u6696\u00b7\u4e24\u8054\u4f9b<\/span>\n        <span class=\"lmai-case-rc-title\">\u84b2\u6c5f\u5927\u6eaa\u8c37\u9f9a\u5973\u58eb \u00b7 \u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/span>\n        <span class=\"lmai-case-rc-desc\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u6e29\u6e7f\u5e73\u8861 + \u5730\u6696\uff0c\u5c71\u8fb9\u522b\u5885\u5b9e\u666f<\/span>\n        <span class=\"lmai-case-rc-arrow\">\u67e5\u770b\u6848\u4f8b \u2192<\/span>\n      <\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=378\" target=\"_blank\" class=\"lmai-case-rel-case\">\n        <span class=\"lmai-case-rc-tag\">\u8bca\u65ad\u6539\u9020<\/span>\n        <span class=\"lmai-case-rc-title\">\u540c\u4e00\u4e1a\u4e3b\u4e24\u4e2a\u5bb6 \u00b7 \u666e\u901a\u7089\u2192\u53cc\u51b7\u51dd\u7089<\/span>\n        <span class=\"lmai-case-rc-desc\">\u540c\u4e1a\u4e3b\u53cc\u5b85\u8bca\u65ad\u6539\u9020\u5b9e\u5f55\uff0c\u51b7\u51dd\u7089\u4e0e\u666e\u901a\u7089\u80fd\u8017\u5bf9\u6bd4<\/span>\n        <span class=\"lmai-case-rc-arrow\">\u67e5\u770b\u6848\u4f8b \u2192<\/span>\n      <\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2553\" target=\"_blank\" class=\"lmai-case-rel-case\">\n        <span class=\"lmai-case-rc-tag\">\u672c\u6848\u70ed\u6e90<\/span>\n        <span class=\"lmai-case-rc-title\">\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\u8be6\u60c5<\/span>\n        <span class=\"lmai-case-rc-desc\">\u8521\u5148\u751f\u672c\u6848\u70ed\u6e90\uff0c\u70ed\u6548\u7387108%\u8be6\u89e3<\/span>\n        <span class=\"lmai-case-rc-arrow\">\u67e5\u770b\u6848\u4f8b \u2192<\/span>\n      <\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" class=\"lmai-case-rel-case\">\n        <span class=\"lmai-case-rc-tag\">\u58c1\u6302\u7089\u9009\u578b<\/span>\n        <span class=\"lmai-case-rc-title\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790<\/span>\n        <span class=\"lmai-case-rc-desc\">\u51b7\u51dd\u7089\/\u53d8\u9891\u7089\u600e\u4e48\u9009\uff0c\u5c0f\u6237\u578b\u5230\u5927\u6237\u578b\u5b9e\u6d4b\u5bf9\u7167<\/span>\n        <span class=\"lmai-case-rc-arrow\">\u67e5\u770b\u6848\u4f8b \u2192<\/span>\n      <\/a>\n    <\/div>\n    <p style=\"text-align:center;margin-top:16px\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" style=\"color:var(--brand);font-size:14px;font-weight:600;text-decoration:none;\">\u67e5\u770b\u5168\u90e8\u5ba2\u6237\u6848\u4f8b \u2192<\/a>\n    <\/p>\n  <\/div>\n<\/div>\n\n<div class=\"lmai-case-about-box\">\n  <h3>\u5173\u4e8e\u9f99\u8109\u6696\u901a<\/h3>\n  <p>\u9f99\u8109\u6696\u901a\uff0c\u521b\u5efa\u4e8e2004\u5e74\uff0c<strong>\u591a\u5e74<\/strong>\u4e13\u6ce8\u6210\u90fd\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf\u670d\u52a1\uff0c\u83f2\u65af\u66fc\/\u4f1f\u661f\/\u66fc\u745e\u5fb7\u5408\u4f5c\u670d\u52a1\u5546\uff0c\u7d2f\u8ba1\u670d\u52a1\u6210\u90fd<strong>2\u4e07+<\/strong>\u5bb6\u5ead\u3002\u4e3b\u8425\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u65b0\u98ce\u3001\u51c0\u6c34\u3001\u8f6f\u6c34\u3001\u70ed\u6c34\uff0c\u4e00\u7ad9\u5f0f\u8bbe\u8ba1\/\u5b89\u88c5\/\u7ef4\u62a4\u3002<\/p>\n  <p style=\"margin-top:10px\">\u670d\u52a1\u7406\u5ff5\uff1a\u8212\u9002\u00b7\u5065\u5eb7\u00b7\u7a33\u5b9a\u00b7\u8282\u80fd<\/p>\n  <p style=\"margin-top:4px;font-style:italic\">\u300c\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u300d<\/p>\n<\/div>\n\n<div class=\"lmai-case-cta-section\">\n  <h3>\ud83d\udcde \u540c\u6237\u578b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b + 20\u5e74\u80fd\u8017\u6d4b\u7b97<\/h3>\n  <p>\u5982\u679c\u4f60\u5bb6\u5957\u5185<strong>80-100\u33a1<\/strong>\u3001\u6ce8\u91cd\u54c1\u8d28\u4e0e\u540e\u671f\u8282\u80fd\u3001\u7ea0\u7ed3\u51b7\u51dd\u7089\u4e0e\u666e\u901a\u7089\u957f\u671f\u6210\u672c\uff0c\u53ef\u9884\u7ea6\u9f99\u8109\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u590d\u6d4b\u8d1f\u8377\uff0c\u51fa\u5177\u4e13\u5c5e\u65b9\u6848\uff08\u5730\u6696\uff09+ \u5168\u5468\u671f\u6210\u672c\u5bf9\u6bd4\u62a5\u8868\u3002<\/p>\n  <div class=\"lmai-case-cta-info\">\n    <div class=\"lmai-case-cta-info-item\">\u7ebf\u4e0b\u95e8\u5e97<span><b>\u5357\u5bcc\u68ee\u7f8e3\u697c \u00b7 \u5317\u5bcc\u68ee\u7f8e5\u697c<\/b>\u83f2\u65af\u66fc\u6388\u6743\u65d7\u8230\u5e97<\/span><\/div>\n    <div class=\"lmai-case-cta-info-item\">\u4e13\u5c5e\u987e\u95ee<span><b>\u5f90\u65b0\u5e73 182-2705-5065<\/b><\/span><\/div>\n  <\/div>\n  <p style=\"font-size:13px;opacity:.85;margin-top:14px\">\u540c\u57ce24\u5c0f\u65f6\u4e0a\u95e8 \u00b7 \u65bd\u5de5\u5168\u7a0b\u62cd\u7167\u540c\u6b65\u65bd\u5de5\u7fa4 \u00b7 \u5173\u952e\u8282\u70b9\u4e09\u65b9\u9a8c\u6536<\/p>\n  <a href=\"tel:18227055065\" class=\"lmai-case-cta-btn\">\u7acb\u5373\u54a8\u8be2 \u00b7 \u514d\u8d39\u52d8\u6d4b<\/a>\n\n<\/div>\n\n<div class=\"lmai-case-link-grid\">\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2553\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\u8be6\u60c5<\/span>\n    <span class=\"lmai-case-lc-d\">\u8521\u5148\u751f\u672c\u6848\u70ed\u6e90\uff0c\u70ed\u6548\u7387108%\u6280\u672f\u89e3\u6790 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u9f99\u8109\u6848\u4f8b\u5e93<\/span>\n    <span class=\"lmai-case-lc-d\">\u66f4\u591a\u6210\u90fd\u5bb6\u5ead\u8212\u9002\u7cfb\u7edf\u5b9e\u666f \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u9009\u578b<\/span>\n    <span class=\"lmai-case-lc-d\">\u51b7\u51dd\u7089vs\u666e\u901a\u7089\u00b7\u5168\u7cfb\u5217\u9009\u578b \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u7cbe\u5de5\u516d\u6b65\u6cd5\u5b89\u88c5\u6807\u51c6<\/span>\n    <span class=\"lmai-case-lc-d\">\u4e94\u6b65\u6cd5 \u00b7 \u6807\u51c6\u7ed3\u6784\u57fa\u51c6 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12902\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u660e\u88c5\u6696\u6c14\u7247\u65b9\u6848<\/span>\n    <span class=\"lmai-case-lc-d\">\u8001\u623f\/\u7cbe\u88c5\u623f\u91c7\u6696\u6539\u9020\u53c2\u8003 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2137\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e95\u5ea7<\/span>\n    <span class=\"lmai-case-lc-d\">\u54c1\u724c\/\u4ea7\u54c1\/\u670d\u52a1\u4e00\u7ad9\u5f0f\u7d22\u5f15 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u6807\u51c6<\/span>\n    <span class=\"lmai-case-lc-d\">\u8282\u70b9\u9a8c\u6536 \u00b7 \u54c1\u8d28\u4fdd\u969c \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12447\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/span>\n    <span class=\"lmai-case-lc-d\">\u6696\u6c14\u7247\u9009\u578b\/\u5b89\u88c5\u5168\u89e3\u6790 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12439\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66<\/span>\n    <span class=\"lmai-case-lc-d\">\u5730\u6696\u8bbe\u8ba1\/\u65bd\u5de5\/\u7ef4\u62a4\u6307\u5357 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10982\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c\u6307\u5357<\/span>\n    <span class=\"lmai-case-lc-d\">\u660e\u88c5\u8d39\u7528\u900f\u660e\u53c2\u8003 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u6210\u90fd\u5730\u6696\u7cfb\u7edf\u4e13\u9879\u6848\u4f8b<\/span>\n    <span class=\"lmai-case-lc-d\">\u540c\u533a\u57df\u5730\u6696\u5b9e\u666f\u53c2\u8003 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=5849\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u6210\u90fd109\u5957\u6237\u578b\u65b9\u6848\u5e93<\/span>\n    <span class=\"lmai-case-lc-d\">\u540c\u6237\u578b\u65b9\u6848\u5bf9\u7167 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3147\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u6bcf\u65e5\u65b0\u6848\u4f8b\u65e5\u66f4\u805a\u5408<\/span>\n    <span class=\"lmai-case-lc-d\">\u6700\u65b0\u6848\u4f8b\u6301\u7eed\u66f4\u65b0 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/span>\n    <span class=\"lmai-case-lc-d\">\u5168\u7ad9\u5185\u5bb9\u7d22\u5f15 \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3011\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u5b98\u7f51\u7ad9\u70b9\u5730\u56fe<\/span>\n    <span class=\"lmai-case-lc-d\">\u5b98\u7f51\u680f\u76ee\u5bfc\u822a \u2192<\/span>\n  <\/a>\n  <a class=\"lmai-case-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\" rel=\"noopener\">\n    <span class=\"lmai-case-lc-t\">\u670d\u52a1\u4fdd\u969c<\/span>\n    <span class=\"lmai-case-lc-d\">\u552e\u540e\/\u8d28\u4fdd\/\u54cd\u5e94\u627f\u8bfa \u2192<\/span>\n  <\/a>\n<\/div>\n\n<div class=\"lmai-case-footer\" id=\"contact\">\n  <h3 style=\"color:var(--brand);font-size:18px;margin-bottom:10px\">\u9f99\u8109\u6696\u901a \u00b7 \u8054\u7cfb\u6211\u4eec<\/h3>\n      <p>\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff1a<strong><a href=\"tel:02886131795\" style=\"color:inherit;text-decoration:none\">028-86131795<\/a><\/strong><\/p>\n      <p>\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff1a<strong><a href=\"tel:02865272586\" style=\"color:inherit;text-decoration:none\">028-65272586<\/a><\/strong><\/p>\n  <p style=\"margin-top:10px\">\u9500\u552e\u987e\u95ee\uff1a\u5f90\u65b0\u5e73 \u00b7 \u9f99\u8109\u6696\u901a\u3000|\u3000\u624b\u673a\uff1a<strong>182-2705-5065<\/strong><\/p>\n  <p style=\"font-size:12px;color:var(--text-l);margin-top:6px\">longmai-nt.com \u00b7 2004\u5e74\u6210\u7acb \u00b7 \u672c\u5730\u81ea\u8425<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u771f\u5b9e\u843d\u5730\u6848\u4f8b \u4e94\u6b65\u6cd5 \u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":15712,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-8190","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6C\u8001\u5e08\u5bb6\uff0c\u9009\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\uff0c\u6253\u9020\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u7684\u5730\u6696\u7cfb\u7edf\u300261\u33a1\u91c7\u6696\u9762\u79ef\u7cbe\u51c6\u914d\u7f6e25KW\u51b7\u51dd\u7089\uff0c\u6bd4\u666e\u901a\u7089\u770120%-28%\uff0c\u51ac\u5b63\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400-600\u5143\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u6807\u51c6\u65bd\u5de5\uff1a\u5145\u6c2e\u710a\u63a5\u3001BIM\u4e09\u7ef4\u653e\u6837\u300122\u9879\u9690\u853d\u9a8c\u6536\u3002\u672c\u6587\u8be6\u89e3\u9009\u578b\u903b\u8f91\u4e0e\u8282\u80fd\u8981\u70b9\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=8190\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6C\u8001\u5e08\u5bb6\uff0c\u9009\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\uff0c\u6253\u9020\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u7684\u5730\u6696\u7cfb\u7edf\u300261\u33a1\u91c7\u6696\u9762\u79ef\u7cbe\u51c6\u914d\u7f6e25KW\u51b7\u51dd\u7089\uff0c\u6bd4\u666e\u901a\u7089\u770120%-28%\uff0c\u51ac\u5b63\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400-600\u5143\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u6807\u51c6\u65bd\u5de5\uff1a\u5145\u6c2e\u710a\u63a5\u3001BIM\u4e09\u7ef4\u653e\u6837\u300122\u9879\u9690\u853d\u9a8c\u6536\u3002\u672c\u6587\u8be6\u89e3\u9009\u578b\u903b\u8f91\u4e0e\u8282\u80fd\u8981\u70b9\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=8190\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-27T07:11:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190\",\"name\":\"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-jjyj-xxp-shejipingmiantu01.jpg\",\"datePublished\":\"2026-07-24T12:30:00+00:00\",\"dateModified\":\"2026-10-27T07:11:03+00:00\",\"description\":\"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6C\u8001\u5e08\u5bb6\uff0c\u9009\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\uff0c\u6253\u9020\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u7684\u5730\u6696\u7cfb\u7edf\u300261\u33a1\u91c7\u6696\u9762\u79ef\u7cbe\u51c6\u914d\u7f6e25KW\u51b7\u51dd\u7089\uff0c\u6bd4\u666e\u901a\u7089\u770120%-28%\uff0c\u51ac\u5b63\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400-600\u5143\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u6807\u51c6\u65bd\u5de5\uff1a\u5145\u6c2e\u710a\u63a5\u3001BIM\u4e09\u7ef4\u653e\u6837\u300122\u9879\u9690\u853d\u9a8c\u6536\u3002\u672c\u6587\u8be6\u89e3\u9009\u578b\u903b\u8f91\u4e0e\u8282\u80fd\u8981\u70b9\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-jjyj-xxp-shejipingmiantu01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-jjyj-xxp-shejipingmiantu01.jpg\",\"width\":755,\"height\":522},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8190#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u58c1\u6302\u7089\u600e\u4e48\u9009\uff1f\u5148\u5206\u6e05\u300c\u9505\u7089\u54c1\u724c\u300d\u548c\u300c\u6696\u6c14\u7cfb\u7edf\u54c1\u724c\u300d\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15712\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6C\u8001\u5e08\u5bb6\uff0c\u9009\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\uff0c\u6253\u9020\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u7684\u5730\u6696\u7cfb\u7edf\u300261\u33a1\u91c7\u6696\u9762\u79ef\u7cbe\u51c6\u914d\u7f6e25KW\u51b7\u51dd\u7089\uff0c\u6bd4\u666e\u901a\u7089\u770120%-28%\uff0c\u51ac\u5b63\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400-600\u5143\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u6807\u51c6\u65bd\u5de5\uff1a\u5145\u6c2e\u710a\u63a5\u3001BIM\u4e09\u7ef4\u653e\u6837\u300122\u9879\u9690\u853d\u9a8c\u6536\u3002\u672c\u6587\u8be6\u89e3\u9009\u578b\u903b\u8f91\u4e0e\u8282\u80fd\u8981\u70b9\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=8190","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6C\u8001\u5e08\u5bb6\uff0c\u9009\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\uff0c\u6253\u9020\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u7684\u5730\u6696\u7cfb\u7edf\u300261\u33a1\u91c7\u6696\u9762\u79ef\u7cbe\u51c6\u914d\u7f6e25KW\u51b7\u51dd\u7089\uff0c\u6bd4\u666e\u901a\u7089\u770120%-28%\uff0c\u51ac\u5b63\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400-600\u5143\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u6807\u51c6\u65bd\u5de5\uff1a\u5145\u6c2e\u710a\u63a5\u3001BIM\u4e09\u7ef4\u653e\u6837\u300122\u9879\u9690\u853d\u9a8c\u6536\u3002\u672c\u6587\u8be6\u89e3\u9009\u578b\u903b\u8f91\u4e0e\u8282\u80fd\u8981\u70b9\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=8190","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-27T07:11:03+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=8190","url":"https:\/\/longmai-nt.com\/?page_id=8190","name":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=8190#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=8190#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu01.jpg","datePublished":"2026-07-24T12:30:00+00:00","dateModified":"2026-10-27T07:11:03+00:00","description":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6C\u8001\u5e08\u5bb6\uff0c\u9009\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089+\u4f1f\u661f5\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7\uff0c\u6253\u9020\u8f85\u6750\u5168\u77e5\u540d\u3001\u540e\u671f\u771f\u8282\u80fd\u7684\u5730\u6696\u7cfb\u7edf\u300261\u33a1\u91c7\u6696\u9762\u79ef\u7cbe\u51c6\u914d\u7f6e25KW\u51b7\u51dd\u7089\uff0c\u6bd4\u666e\u901a\u7089\u770120%-28%\uff0c\u51ac\u5b63\u6708\u5747\u71c3\u6c14\u8d39\u7ea6400-600\u5143\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u6807\u51c6\u65bd\u5de5\uff1a\u5145\u6c2e\u710a\u63a5\u3001BIM\u4e09\u7ef4\u653e\u6837\u300122\u9879\u9690\u853d\u9a8c\u6536\u3002\u672c\u6587\u8be6\u89e3\u9009\u578b\u903b\u8f91\u4e0e\u8282\u80fd\u8981\u70b9\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=8190#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=8190"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=8190#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-jjyj-xxp-shejipingmiantu01.jpg","width":755,"height":522},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=8190#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u58c1\u6302\u7089\u600e\u4e48\u9009\uff1f\u5148\u5206\u6e05\u300c\u9505\u7089\u54c1\u724c\u300d\u548c\u300c\u6696\u6c14\u7cfb\u7edf\u54c1\u724c\u300d","item":"https:\/\/longmai-nt.com\/?page_id=15712"},{"@type":"ListItem","position":3,"name":"\u6210\u90fd\u9526\u6c5f\u533a\u9526\u6c5f\u9038\u5bb6 \u00b7 \u83dc\u8001\u5e08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/8190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8190"}],"version-history":[{"count":6,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/8190\/revisions"}],"predecessor-version":[{"id":16679,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/8190\/revisions\/16679"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15712"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}