{"id":835,"date":"2026-05-15T15:59:02","date_gmt":"2026-05-15T07:59:02","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=835"},"modified":"2026-11-12T21:25:11","modified_gmt":"2026-11-12T13:25:11","slug":"%e5%8d%9a%e4%b8%96%e5%a3%81%e6%8c%82%e7%82%89%e7%bb%bc%e5%90%88%e6%a0%b7%e5%86%8c-%e5%ae%8c%e6%95%b4%e8%a7%a3%e6%9e%90%e6%8a%a5%e5%91%8a","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=835","title":{"rendered":"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u535a\u4e16<a href=\"https:\/\/longmai-nt.com\/?page_id=16477\" title=\"\u58c1\u6302\u7089\">\u58c1\u6302\u7089<\/a>\u5168\u7cfb\u5217\u7545\u9500\u4ea7\u54c1\u6574\u5408\u8d44\u6599<\/h2>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u7545\u9500\u4ea7\u54c1\u76ee\u5f55<\/h3>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><a href=\"#ppygs1\">\u54c1\u724c\u4e0e\u516c\u53f8\u4ecb\u7ecd<\/a><\/li>\n<li><a href=\"#lljs1\">\u51b7\u51dd\u6280\u672f\u6838\u5fc3<\/a><\/li>\n<li><a href=\"#cpzl1\">\u4ea7\u54c1\u7cfb\u5217\u603b\u89c8<\/a><\/li>\n<li><a href=\"#qjxl1\">\u65d7\u8230\u7cfb\u5217<\/a><\/li>\n<li><a href=\"#gdxl1\">\u9ad8\u7aef\u7cfb\u5217<\/a><\/li>\n<li><a href=\"#dgyzjk\">\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\u7cfb\u5217<\/a><\/li>\n<li><a href=\"#jdpzxl\">\u7ecf\u5178\u54c1\u8d28\u7cfb\u5217<\/a><\/li>\n<li><a href=\"#jjsyxl\">\u7ecf\u6d4e\u5b9e\u7528\u7cfb\u5217<\/a><\/li>\n<li><a href=\"#znkzxt\">\u667a\u80fd\u63a7\u5236\u7cfb\u7edf<\/a><\/li>\n<li><a href=\"#rsxt1\">\u70ed\u6c34\u7cfb\u7edf\uff08\u6c34\u7bb1\uff09<\/a><\/li>\n<li><a href=\"#gsxxylxfs\">\u516c\u53f8\u4fe1\u606f\u4e0e\u8054\u7cfb\u65b9\u5f0f<\/a><\/li>\n<\/ol>\n<\/div>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">\u9644\uff1a\u535a\u4e16\u7efc\u5408\u6837\u518c\u76ee\u5f55<\/h3>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><a href=\"#ppygsjs\">\u54c1\u724c\u4e0e\u516c\u53f8\u4ecb\u7ecd<\/a><\/li>\n<li><a href=\"#lnjshx\">\u51b7\u51dd\u6280\u672f\u6838\u5fc3<\/a><\/li>\n<li><a href=\"#cpxlxj\">\u4ea7\u54c1\u7cfb\u5217\u8be6\u89e3<\/a><\/li>\n<li><a href=\"#kzxt\">\u63a7\u5236\u7cfb\u7edf<\/a><\/li>\n<li><a href=\"#rsxt\">\u70ed\u6c34\u7cfb\u7edf\uff08\u6c34\u7bb1\uff09<\/a><\/li>\n<li><a href=\"#gsxxysjx\">\u516c\u53f8\u4fe1\u606f\u4e0e\u65f6\u95f4\u7ebf<\/a><\/li>\n<li><a href=\"#cptj\">\u535a\u4e16\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\u9274<\/a><\/li>\n<\/ol>\n<\/div>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6574\u5408\u6765\u6e90<\/strong>\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u535a\u4e16\u58c1\u6302\u7089\u7efc\u5408\u6837\u518c\uff08FLBook 52\u9875\u5b8c\u6574\u7248\uff09<\/li>\n<li>\u535a\u4e16G7\u955c\u9762\u7248\u6837\u518c\uff08PDF 8\u9875\uff09<\/li>\n<li>\u535a\u4e16C3260W\u6837\u518c\uff08FLBook 4\u9875\uff09<\/li>\n<li>\u535a\u4e16G6Z\u8ffd\u5149\u7248plus\u6837\u518c\uff08FLBook 4\u9875\uff09<\/li>\n<li>\u535a\u4e16\u667a\u80fd\u91c7\u6696\u63a7\u5236\u5668MR120i\u9875\u9762<\/li>\n<li>\u535a\u4e16G7350i W\uff08G7 Pro\uff09\u4ea7\u54c1\u8be6\u60c5\u9875<\/li>\n<li>\u535a\u4e16\u5b98\u65b9\u7f51\u7ad9\u4ea7\u54c1\u9875\u9762<\/li>\n<li>\u9f99\u8109\u6696\u901a\u4ea7\u54c1\u6307\u5357<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u6574\u5408\u65e5\u671f<\/strong>\uff1a2026-05-15<\/p>\n<\/blockquote>\n<h2 id=\"ppygs1\" class=\"wp-block-heading\">\u4e00\u3001\u54c1\u724c\u4e0e\u516c\u53f8\u4ecb\u7ecd<\/h2>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u96c6\u56e2<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u5168\u7403\u9886\u5148\u7684\u6280\u672f\u53ca\u670d\u52a1\u4f9b\u5e94\u5546<\/li>\n<li>\u622a\u81f32023\u5e7412\u670831\u65e5\uff0c\u7ea6<strong>427,600\u540d<\/strong>\u5458\u5de5<\/li>\n<li>2023\u8d22\u5e74\u9500\u552e\u989d\u8fbe<strong>916\u4ebf\u6b27\u5143<\/strong><\/li>\n<li>\u4e1a\u52a1\u6db5\u76d64\u4e2a\u4e1a\u52a1\u9886\u57df\uff1a\u79fb\u52a8\u51fa\u884c\u3001\u5de5\u4e1a\u6280\u672f\u3001\u6d88\u8d39\u54c1\u3001\u80fd\u6e90\u4e0e\u5efa\u7b51\u6280\u672f<\/li>\n<li>\u96c6\u56e2\u5305\u62ec<strong>\u7f57\u4f2f\u7279\u00b7\u535a\u4e16\u6709\u9650\u516c\u53f8<\/strong>\u53ca\u5176\u904d\u5e03\u5168\u740360\u4e2a\u56fd\u5bb6\u7684\u7ea6470\u5bb6\u5206\u516c\u53f8\u548c\u533a\u57df\u6027\u516c\u53f8<\/li>\n<li>\u7f57\u4f2f\u7279\u00b7\u535a\u4e16\u57fa\u91d1\u6301\u80a1<strong>94%<\/strong><\/li>\n<li>\u5e03\u5c40\u5168128\u4e2a\u56fd\u5bb6\u548c\u5730\u533a\uff0c\u62e5\u670944,000\u540d\u8f6f\u4ef6\u5de5\u7a0b\u5e08<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u8212\u9002\u79d1\u6280\u4e8b\u4e1a\u90e8<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u6b27\u6d32\u9886\u5148\u7684\u667a\u80fd\u3001\u53ef\u6301\u7eed\u3001\u8282\u80fd\u4f9b\u6696\u3001\u5236\u51b7\u3001\u8212\u9002\u5bb6\u5c45\u53ca\u8fc7\u7a0b\u52a0\u70ed\u89e3\u51b3\u65b9\u6848\u63d0\u4f9b\u5546<\/li>\n<li>2023\u5e74\u9500\u552e\u989d\u7ea6<strong>50\u4ebf\u6b27\u5143<\/strong>\uff0c\u5458\u5de5\u7ea6<strong>14,800\u4eba<\/strong><\/li>\n<li>\u65d7\u4e0b\u62e5\u6709\u591a\u4e2a\u5f3a\u5927\u7684\u56fd\u9645\u548c\u5730\u533a\u54c1\u724c\uff0c20\u4e2a\u751f\u4ea7\u57fa\u5730\u904d\u5e03\u5168\u7403<\/li>\n<li>\u4ea7\u54c1\u7cfb\u5217\u5305\u62ec\uff1a<strong>C9000\u3001C8700<\/strong><\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u5168\u7403\u5de5\u5382\u5e03\u5c40<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u5382<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u56fd\u5bb6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Aveiro<\/td>\n<td>\u8461\u8404\u7259\u00b7\u963f\u5a01\u7f57<\/td>\n<td>\u4f4d\u4e8e\u8461\u8404\u7259\u897f\u5317\u90e8\u6ce2\u5c14\u56fe\u4ee5\u535770\u516c\u91cc\uff0c1977\u5e74\u5efa\uff0c1996\u5e74\u5f00\u59cb\u751f\u4ea7\u58c1\u6302\u7089\uff0c\u5458\u5de51,000\u540d<\/td>\n<\/tr>\n<tr>\n<td>Saint Th\u00e9gonnec<\/td>\n<td>\u6cd5\u56fd\u00b7\u5723\u6cf0\u6208\u5185\u514b<\/td>\n<td>\u751f\u4ea7\u4ece\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u3001\u5bb6\u7528\u70ed\u6c34\u5668\u3001\u5546\/\u5bb6\u7528\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u3001\u5de5\u4e1a\u9505\u7089\u7cfb\u7edf\u5230\u70ed\u6cf5\u4f9b\u7535\u7cfb\u7edf\u7b49\uff0c\u51e0\u4e4e\u8986\u76d6\u5168\u7ebf\u6696\u901a\u4ea7\u54c1<\/td>\n<\/tr>\n<tr>\n<td>Worcester<\/td>\n<td>\u82f1\u56fd\u00b7\u4f0d\u65af\u7279<\/td>\n<td>\u6210\u7acb\u4e8e1962\u5e74\uff0c1996\u5e74\u6210\u4e3a\u5168\u7403\u535a\u4e16\u96c6\u56e2\u7684\u4e00\u90e8\u5206<\/td>\n<\/tr>\n<tr>\n<td>Drancy<\/td>\n<td>\u6cd5\u56fd\u00b7\u5fb7\u6717\u897f<\/td>\n<td>\u6210\u7acb\u4e8e2001\u5e74\uff0c\u5de5\u5382\u91c7\u7528\u5de5\u4e1a4.0\u5236\u9020\u7406\u5ff5<\/td>\n<\/tr>\n<tr>\n<td>Deventer<\/td>\n<td>\u8377\u5170\u00b7\u4ee3\u82ac\u7279\u5c14<\/td>\n<td>\u5de5\u5382\u96c6\u7814\u53d1\u3001\u751f\u4ea7\u3001\u9500\u552e\u53ca\u7269\u6d41\u4e8e\u4e00\u4f53<\/td>\n<\/tr>\n<tr>\n<td>Manisa<\/td>\n<td>\u571f\u8033\u5176\u00b7\u9a6c\u5c3c\u8428<\/td>\n<td>\u627f\u535a\u4e16\u5236\u9020\u4f53\u7cfb\u53ca\u5de5\u4e1a4.0\u7406\u5ff5\uff0c\u751f\u4ea7\u8fc7\u7a0b\u91c7\u7528\u81ea\u52a8\u5316\u3001\u6570\u5b57\u5316\u548c\u5927\u6570\u636e\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td>Shanghai<\/td>\n<td>\u4e2d\u56fd\u00b7\u4e0a\u6d77<\/td>\n<td>\u535a\u4e16\u70ed\u529b\u6280\u672f\u5728\u534e\u91cd\u70b9\u6295\u8d44\u9879\u76ee\u4e4b\u4e00\uff0c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u3001\u71c3\u6c14\u70ed\u6c34\u5668\u53ca\u592a\u9633\u80fd\u5e73\u677f\u96c6\u70ed\u5668\u751f\u4ea7\u57fa\u5730<\/td>\n<\/tr>\n<tr>\n<td>Wernau<\/td>\n<td>\u5fb7\u56fd\u00b7\u97e6\u5c14\u7459<\/td>\n<td>\u8d1f\u8d23\u91c7\u6696\u7cfb\u7edf\u7684\u7814\u53d1\u3001\u751f\u4ea7\u548c\u9500\u552e\uff0c\u5458\u5de51,400\u4f59\u4eba<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"lljs1\" class=\"wp-block-heading\">\u4e8c\u3001\u51b7\u51dd\u6280\u672f\u6838\u5fc3<\/h2>\n<h3 class=\"wp-block-heading\">\u4ec0\u4e48\u662f\u51b7\u51dd\u7089<\/h3>\n<p class=\"wp-block-paragraph\">\u51b7\u51dd\u5f0f\u58c1\u6302\u7089\u91c7\u7528<strong>\u51b7\u51dd\u6280\u672f<\/strong>\uff0c\u5c06\u70df\u6c14\u4e2d\u7684\u4f59\u70ed\u518d\u6b21\u56de\u6536\u5229\u7528\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u4f20\u7edf\u9505\u7089 vs \u51b7\u51dd\u7089 \u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4f20\u7edf\u975e\u51b7\u51dd\u6280\u672f<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u535a\u4e16\u51b7\u51dd\u6280\u672f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u80fd\u6548<\/td>\n<td>\u6309\u4f4e\u4f4d\u70ed\u503c<\/td>\n<td>\u6309\u4f4e\u4f4d\u70ed\u503c<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u84b8\u6c14\u70ed\u91cf\u635f\u5931<\/td>\n<td>\u5927<\/td>\n<td>\u5c0f<\/td>\n<\/tr>\n<tr>\n<td>\u70df\u6c14\u663e\u70ed\u635f\u5931<\/td>\n<td>\u5927<\/td>\n<td>\u5c0f<\/td>\n<\/tr>\n<tr>\n<td>\u8f90\u5c04\u635f\u5931<\/td>\n<td>\u5927<\/td>\n<td>\u5c0f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4f9b\u6696\u70ed\u6548\u7387<\/strong><\/td>\n<td><strong>93%<\/strong><\/td>\n<td><strong>108%<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">*\u6ce8\uff1a\u4ec5\u9488\u5bf9\u535a\u4e16\u58c1\u6302\u7089\u4ea7\u54c1<br \/>**\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a\uff1a\u68c0\u6d4b\u4ea7\u54c1\u578b\u53f7 L1P27-G6100W 24 CG\uff0c30%\u989d\u5b9a\u70ed\u8d1f\u8377\u6761\u4ef6\u4e0b\uff1bL1GBQ24-GC7100W 25 C\uff0c30%\u989d\u5b9a\u70ed\u8d1f\u8377\u6761\u4ef6<\/p>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u51b7\u51dd\u6838\u5fc3\u6280\u672f<\/h3>\n<h4 class=\"wp-block-heading\">1. \u5168\u9884\u6df7\u5f0f\u71c3\u70e7\u7ba1\u7406\u7cfb\u7edf<\/h4>\n<p class=\"wp-block-paragraph\">\u4f7f\u71c3\u6c14\u548c\u7a7a\u6c14\u6309\u8f83\u4f18\u6bd4\u4f8b\u9884\u6df7\uff0c\u4ece\u800c\u71c3\u70e7\u8fbe\u5230\u66f4\u4f73\u72b6\u6001\uff0c\u71c3\u70e7\u6548\u7387\u63d0\u9ad8\u3002\u4f4e\u6e29\u56de\u6c34\u5438\u6536\u9ad8\u6e29\u70df\u6c14\u70ed\u91cf\uff0c\u4ea7\u751f\u51b7\u51dd\u6548\u679c\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u6838\u5fc3\u7ec4\u4ef6\uff1a\u53d8\u9891\u98ce\u673a \u2192 \u9884\u6df7\u8154 \u2192 WB5\u6362\u70ed\u5668 \u2192 \u71c3\u6c14\u6bd4\u4f8b\u9600<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">2. \u535a\u4e16WB5\u7ffc\u7fc5\u6c34\u51b7\u6362\u70ed\u5668<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u91d1\u5c5e\u7ea4\u7ef4\u71c3\u70e7\u5668<\/strong>\uff1a\u71c3\u70e7\u6548\u7387\u9ad8\uff0c\u6c61\u67d3\u7269\u6392\u653e\u4f4e\uff0c\u706b\u7130\u7a33\u5b9a\u5b89\u5168\uff0c\u51b7\u51dd\u6c34\u7684\u6392\u653e\u66f4\u5bb9\u6613\u65b9\u4fbf<\/li>\n<li><strong>3D\u6362\u70ed\u7fc5\u7247<\/strong>\uff1a\u8d85\u5927\u6362\u70ed\u9762\u79ef\uff0c\u6bcf\u4e2a\u5c0f\u7fc5\u7247\u7684\u8868\u9762\u79ef\u90fd\u662f\u6362\u70ed\u9762\u79ef\u7684\u5ef6\u4f38<\/li>\n<li><strong>\u5927\u6c34\u9053\uff0c\u5bbd\u58c1\u539a<\/strong>\uff1a\u5927\u6c34\u9053\uff0c\u4e0d\u6613\u5835\u585e\u7ed3\u57a2\uff0c\u5bbd\u58c1\u539a\uff0c\u589e\u52a0\u5f3a\u5ea6\uff0c\u963b\u9694\u566a\u58f0<\/li>\n<li><strong>\u4f7f\u7528\u7845\u94dd\u5408\u91d1\u6750\u8d28<\/strong>\uff1a\u6362\u70ed\u6548\u7387\u9ad8\uff0c\u8010\u8150\u8680\u6027\u5f3a\u3002\u91c7\u7528\u94f8\u9020\u5de5\u827a\uff0c\u65e0\u710a\u7f1d\uff0c\u81f4\u5bc6\u6027\u597d<\/li>\n<li><strong>\u5168\u6c34\u51b7\u7ed3\u6784<\/strong>\uff1a\u5b8c\u5168\u4f9d\u9760\u6c34\u5438\u6536\u70ed\u91cf\uff0c\u65e0\u8010\u706b\u70ed<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">3. \u516b\u5927\u6838\u5fc3\u6280\u672f<\/h4>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>\u5e02\u573a\u9500\u91cf\u767e\u4e07\u7ea7\u7845\u94f8\u94dd\u4e3b\u6362\u70ed\u5668<\/strong>&nbsp;\u2014 \u65e0\u710a\u7f1d\u6f0f\u6c34\u98ce\u9669\uff0c\u7845\u94dd\u5408\u91d1\u4e00\u4f53\u94f8\u9020\u9020\u578b\uff0c\u65e0\u710a\u70b9<\/li>\n<li><strong>\u9876\u7f6e\u5f0f\u8868\u9762\u71c3\u70e7\u5668<\/strong>&nbsp;\u2014 \u9876\u7f6e\u5f0f\u8bbe\u8ba1\uff0c\u51b7\u6c34\u4e0d\u63a5\u89e6\u71c3\u70e7\u5668\uff0c\u5ef6\u957f\u4f7f\u7528\u5bff\u547d<\/li>\n<li><strong>\u535a\u4e16\u5168\u9884\u6df7\u71c3\u70e7\u6280\u672f<\/strong>&nbsp;\u2014 \u7a7a\u6c14\u4e0e\u71c3\u6c14\u6309\u9002\u91cf\u914d\u6bd4\u71c3\u70e7\uff0c\u4fdd\u8bc1\u6548\u7387\uff0c\u51cf\u5c11\u6709\u5bb3\u7269\u8d28\u6392\u653e<\/li>\n<li><strong>\u667a\u80fd\u6df7\u5408\uff0c\u4f4e\u566a\u9ad8\u6548<\/strong>&nbsp;\u2014 \u6309\u7167\u5b9e\u9645\u7cfb\u7edf\u9700\u6c42\u8c03\u8282\u98ce\u673a\u8f6c\u901f\uff0c\u8282\u7ea6\u80fd\u8017\uff0c\u4fdd\u8bc1\u6548\u7387\uff0c\u964d\u4f4e\u566a\u97f3<\/li>\n<li><strong>\u53d8\u9891\u6cf5\uff08ErP\u6cf5\uff09<\/strong>&nbsp;\u2014 \u6839\u636e\u7cfb\u7edf\u80fd\u9700\u6c42\u81ea\u52a8\u8c03\u8282\u6863\u4f4d\uff0c\u8282\u80fd\u3001\u9759\u97f3<\/li>\n<li><strong>\u535a\u4e16\u81ea\u4e3b\u7814\u53d1Heatronic III\u667a\u80fd\u63a7\u5236\u5668<\/strong>&nbsp;\u2014 \u7ed3\u5408\u5927\u9762\u79ef\u677f\u5f0f\u6362\u70ed\u5668\u548c\u9ad8\u7cbe\u5ea6\u6d41\u91cf\u4f20\u611f\u5668\u7cbe\u786e\u63a7\u5236\u751f\u6d3b\u70ed\u6c34\u6c34\u6e29<\/li>\n<li><strong>\u8d85\u5927\u677f\u5f0f\u6362\u70ed\u5668<\/strong>&nbsp;\u2014 \u8d85\u5927\u9762\u79ef\u4e0d\u9508\u94a2\u677f\u5f0f\u6362\u70ed\u5668\uff0c\u751f\u6d3b\u70ed\u6c34\u6362\u70ed\u8fc5\u901f\uff0c\u6e29\u5ea6\u66f4\u7a33\u5b9a<\/li>\n<li><strong>\u535a\u4e16\u70ed\u6c34\u7cfb\u7edf<\/strong>&nbsp;\u2014 16kg\/min\u4ea7\u70ed\u91cf\uff0c\u91cd\u65b0\u5b9a\u4e49\u535a\u4e1625kW\u70ed\u6c34\u6807\u51c6\uff1b25KW\u91c7\u6696\u7089\u9001\u53d116kg\/min\u70ed\u6c34\u91cf\uff0c\u8f83\u4e0a\u4e00\u4ee3\u70ed\u6c34\u6d41\u91cf\u63d0\u534725%<\/li>\n<\/ol>\n<h4 class=\"wp-block-heading\">4. \u535a\u4e16\u6052\u6e29\u63a7\u7130\u6280\u672f<\/h4>\n<p class=\"wp-block-paragraph\">\u7cfb\u7edf\u63a7\u5236 \u667a\u80fd\u4e92\u8054 \u6052\u6e29\u8212\u9002 \u9ad8\u6548\u8282\u80fd<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5c06\u58c1\u6302\u7089\u706b\u7130\u63a7\u5236\u4e0e\u623f\u95f4\u6e29\u5ea6\u5b8c\u7f8e\u7ed3\u5408<\/li>\n<li>\u6839\u636e\u5f53\u524d\u623f\u95f4\u6e29\u5ea6\u8bbe\u5b9a\u6e29\u5ea6\u7684\u504f\u5dee\uff0c\u81ea\u52a8\u8c03\u8282\u58c1\u6302\u7089\u51fa\u6c34\u6e29\u5ea6\u548c\u58c1\u6302\u7089\u706b\u529b\u5927\u5c0f\uff0c\u4f7f\u623f\u95f4\u6e29\u5ea6\u7a33\u5b9a\u5728\u8bbe\u5b9a\u6e29\u5ea6<\/li>\n<li>\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u51cf\u5c11\u542f\u505c\u6b21\u6570\uff0c\u63d0\u9ad8\u6574\u4e2a\u91c7\u6696\u7cfb\u7edf\u7684\u7a33\u5b9a\u6027<\/li>\n<\/ul>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"cpzl1\" class=\"wp-block-heading\">\u4e09\u3001\u4ea7\u54c1\u7cfb\u5217\u603b\u89c8<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7279\u5f81<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u5730<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Condens 9000i WM<\/strong><\/td>\n<td>GC 9000i WM<\/td>\n<td>\u65d7\u8230\u96c6\u6210\u51b7\u51dd\u7089<\/td>\n<td>150L\u5206\u5c42\u6c34\u7bb1\uff0cCMS\u71c3\u70e7\u7ba1\u7406\uff0c\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3<\/td>\n<td>\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td><strong>Condens 8700i W<\/strong><\/td>\n<td>GC 8700i WM (24\/35kW)<\/td>\n<td>\u51b7\u51dd\u5f0f\u91c7\u6696\u70ed\u6c34\u7089<\/td>\n<td>22L\u5347\u4f4d\uff0c\u6c22\u80fd\u5c31\u7eea\uff0c50\u4f59\u91cd\u5b89\u5168\u4fdd\u62a4<\/td>\n<td>\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td><strong>Condens 7100 W<\/strong><\/td>\n<td>OC 7100W (24-39kW)<\/td>\n<td>\u5de5\u4e1a4.0\u5236\u9020<\/td>\n<td>\u5168\u7403\u9500\u91cf\u8d85160\u4e07\uff0c\u516b\u5927\u6838\u5fc3\u6280\u672f<\/td>\n<td>\u5fb7\u56fd\u97e6\u5c14\u7459<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6b27\u6d32\u8d35\u65cf<\/strong><\/td>\n<td>DNZ\u7cfb\u5217 (25\/35kW)<\/td>\n<td>\u51b7\u51dd\u5f0f\u6696\u6d74\u4e24\u7528<\/td>\n<td>\u84dd\u7ed2\u7130\uff0cCHG\u6c34\u529b\u5347\u7ea7\uff0c\u6b27\u6d32\u4e09\u661f\u8ba4\u8bc1<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G8550i W<\/strong><\/td>\n<td>G8550i W (24kW)<\/td>\n<td>\u5fb7\u539f\u88c5\u8fdb\u53e3<\/td>\n<td>\u7b2c4\u4ee3\u70ed\u80fd\u82afEMS2.0\uff0c\u5168\u6c14\u5019\u6052\u6e29<\/td>\n<td>\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248<\/strong><\/td>\n<td>ZWC\u7cfb\u5217 (24\/28\/35kW)<\/td>\n<td>\u7ecf\u5178\u54c1\u8d28<\/td>\n<td>93%\u70ed\u6548\u7387\uff0c10\u9879\u5b89\u5168\u4fdd\u62a4\uff0c100\u4e07+\u9500\u91cf<\/td>\n<td>\u6b27\u6d32<\/td>\n<\/tr>\n<tr>\n<td><strong>G7\u955c\u9762\u7248<\/strong><\/td>\n<td>G7200W (24\/28kW)<\/td>\n<td>\u5149\u5f71\u73bb\u7483\u9762\u677f<\/td>\n<td>\u4e00\u7ea7\u9759\u97f3\uff0cWiFi\u64cd\u63a7\uff0c\u4e13\u5229\u6392\u70df<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G7350i W (G7 Pro)<\/strong><\/td>\n<td>L1P27-G7350iW 24CD<\/td>\n<td>\u5e38\u89c4\u58c1\u6302\u7089<\/td>\n<td>\u5206\u6bb5\u71c3\u70e7\uff0c\u56db\u5b63\u6052\u6e29\uff0c\u5149\u5f71\u73bb\u7483\u9762\u677f<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>C3260W<\/strong><\/td>\n<td>GC3260W 25C<\/td>\n<td>\u51b7\u51dd\u58c1\u6302\u7089<\/td>\n<td>\u5168\u9884\u6df7\u51b7\u51dd\uff0c\u4e00\u7ea7\u80fd\u6548\uff0c108%\u70ed\u6548\u7387<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G6Z\u8ffd\u5149\u7248plus<\/strong><\/td>\n<td>G6Z Plus<\/td>\n<td>\u5e38\u89c4\u58c1\u6302\u7089<\/td>\n<td>\u7d27\u51d1\u5c3a\u5bf8\uff0c\u7cbe\u51c6\u63a7\u6e29\uff0c\u9ad8\u6548\u8282\u80fd<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G6300W<\/strong><\/td>\n<td>G6300W (18\/22kW)<\/td>\n<td>\u7ecf\u6d4e\u5b9e\u7528<\/td>\n<td>48dB(A)\u4f4e\u566a\uff0c\u6781\u7aef\u73af\u5883\u901a\u7528<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G6100W<\/strong><\/td>\n<td>L1P31-G6100W 28 CG<\/td>\n<td>\u8fdb\u53e3\u5e38\u89c4\u7089<\/td>\n<td>92%\u70ed\u6548\u7387\uff0c\u677f\u5f0f\u6362\u70ed\uff0c\u7d27\u51d1\u5c3a\u5bf8<\/td>\n<td>\u6b27\u6d32\u8fdb\u53e3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<ul>\n<li>\u2705<a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" title=\"\u6210\u90fd\u5730\u6696\">\u5730\u6696<\/a>\u5de5\u51b5\uff1a80-140\u33a1\u91c7\u6696\u9762\u79ef\u5e73\u5c42\uff1b\u9876\u697c\u3001\u4fdd\u6e29\u5dee\u8001\u623f\u6237\u578b\uff0c\u70ed\u8d1f\u8377\u9700\u8981\u590d\u6838\uff0c\u529f\u7387\u5efa\u8bae\u5411\u4e0a\u8bc4\u4f30\uff1b<\/li>\n<li>\u2705\u660e\u88c5\u6696\u6c14\u7247\u5de5\u51b5\uff1a\u4e24\u7528\u7089\u6a21\u5f0f\uff0c\u6ce8\u610f<mark>\u4e24\u7528\u7089\u70ed\u6c34\u4e3a\u517c\u804c\u8f93\u51fa\uff0c\u591a\u536b\u751f\u95f4\u540c\u65f6\u7528\u6c34\u4f1a\u51fa\u73b0\u6c34\u91cf\u7f29\u6c34<\/mark>\uff1b\u5bf9\u70ed\u6c34\u4f53\u9a8c\u8981\u6c42\u9ad8\uff0c\u5efa\u8bae\u4fdd\u7559\u539f\u6709\u70ed\u6c34\u5668\uff0c\u91c7\u6696\u9505\u7089\u53ea\u8d1f\u8d23\u4f9b\u6696\uff1b\u8be6\u89c1 <a href=\"?page_id=13941\">\u71c3\u6c14\u58c1\u6302\u7089\u548c\u70ed\u6c34\u5668\u54ea\u4e2a\u597d<\/a>\u3002<\/li>\n<li>\u26a0\ufe0f\u6210\u90fd\u8001\u5c0f\u533a\u52a1\u5fc5\u590d\u6838\u71c3\u6c14\u8868\uff1aG1.6\u8868\u4f18\u5148\u8bc4\u4f30\u4f9b\u6c14\u4f59\u91cf\uff0c\u5927\u6237\u578b\u5efa\u8baeG2.5\u71c3\u6c14\u8868\uff1b<\/li>\n<li>\u26a0\ufe0f\u51b7\u51dd\u7089\u53d1\u6325\u8282\u80fd\u4f18\u52bf\uff0c\u4f18\u5148\u4f4e\u6e29\u4f9b\u6c34\u5730\u6696\u5de5\u51b5\uff1b\u6696\u6c14\u7247\u9ad8\u6e29\u5de5\u51b5\u51b7\u51dd\u6536\u76ca\u4f1a\u4e0b\u964d\u3002<\/li>\n<\/ul>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"qjxl1\" class=\"wp-block-heading\">\u56db\u3001\u65d7\u8230\u7cfb\u5217<\/h2>\n<h3 class=\"wp-block-heading\">CONDENS 9000I WM \u2014 \u535a\u4e16\u65d7\u8230\u6b3e\u96c6\u6210\u51b7\u51dd\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\uff0c\u81f3\u81fb\u8212\u9002\u4eab\u53d7<\/li>\n<li><strong>\u9002\u7528\u573a\u666f<\/strong>\uff1a\u96c5\u5962\u8c6a\u5b85\u4e4b\u9009\uff0c\u89d2\u843d\u6536\u7eb3\uff0c\u8282\u7701\u7a7a\u95f4\uff0c\u53ef\u7075\u6d3b\u5b89\u88c5\u5728\u53a8\u623f\u3001\u5ba2\u5385\u7b49\u5904<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u535a\u4e16DNA\u8bbe\u8ba1<\/strong>\uff1a\u5f02\u7279\u73bb\u7483\u9762\u677f\uff08\u8010\u6e29\u9632\u6f6e\uff0c\u9ad8\u96c5\u65f6\u5c1a\uff09\uff1b\u5706\u89d2\u8bbe\u8ba1\uff08\u67d4\u548c\u9632\u649e\uff0c\u7cbe\u81f4\u7f8e\u89c2\uff09\uff1b\u6781\u7b80\u7528\u6237\u754c\u9762\uff08\u667a\u80fd\u64cd\u4f5c\uff0c\u79d1\u6280\u8d28\u611f\uff09<\/li>\n<li><strong>CMS\u71c3\u70e7\u7ba1\u7406\u7cfb\u7edf<\/strong>\uff1a\u535a\u4e16\u6700\u65b0\u4e00\u4ee3CMS\u71c3\u70e7\u7ba1\u7406\u7cfb\u7edf\uff0c\u53ef\u4ece10%-100%\u53d8\u8c03\u8282\u706b\u529b\uff0c\u6700\u5c0f\u706b\u529b\u53ef\u964d\u81f33kW\uff08\u4ecd\u6ee1\u8db3\u5730\u677f\u91c7\u6696\u4fdd\u6e29\u65f6\u7684\u8f83\u5c0f\u52a0\u70ed\u9700\u6c42\uff09\uff0c\u6e29\u5ea6\u8f93\u51fa\u66f4\u7a33\u5b9a\u7cbe\u51c6\uff0c\u91c7\u6696\u66f4\u5177\u9ad8\u8212\u9002\u5ea6<\/li>\n<li><strong>\u667a\u80fd\u6e29\u63a7\u5668CW400<\/strong>\uff1a\u81ea\u52a8\u611f\u5e94\u663c\u591c\u6e29\u5dee\u53ca\u5ba4\u5185\u6e29\u5ea6\u53d8\u5316\uff0c\u8ba1\u7b97\u5e76\u8c03\u8282\u9002\u5408\u5f53\u524d\u7684\u91c7\u6696\u6e29\u5ea6<\/li>\n<li><strong>WB5\u7ffc\u7fc5\u6c34\u51b7\u6362\u70ed\u5668<\/strong><\/li>\n<li><strong>\u9002\u4eab\u7545\u5feb\"\u6d17\"\u60a6<\/strong>\uff1a\u8d85\u539a\u5927\u677f\u5f0f\u6362\u70ed\u5668\uff0c\u5feb\u901f\u8fbe\u5230\u9884\u8bbe\u70ed\u5ea6\uff0c\u9884\u70ed\u65e0\u9700\u7b49\u5f85\uff1b\u5185\u7f6e150L\u5206\u5c42\u6c34\u7bb1\uff0c\u5236\u70ed\u8fc5\u901f\uff0c\u53ef\u652f\u6301\u540c\u4e00\u65f6\u6bb5\u591a\u4e2a\u70ed\u6c34\u9f99\u5934\u5904\u4e8e\u5f00\u542f\u72b6\u6001<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\" id=\"GC9000\"><strong>GC 9000I WM \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">GC 9000I WM<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u529f\u7387\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>30.8<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>29.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>36.0<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa(30)\u00b0C<\/td>\n<td>kW<\/td>\n<td>9.5<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8d1f\u8377<\/td>\n<td>kW<\/td>\n<td>35.0<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c1413T<\/td>\n<td>m\u00b3\/h<\/td>\n<td>3.7<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14\u538b\u529b<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b\u9002\u7528\u8303\u56f4<\/td>\n<td>Pa<\/td>\n<td>1500-3000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u6c14\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90<\/td>\n<td>-<\/td>\n<td>1~<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u8def<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u6c34\u91cf(L\u2084\u2080=30\u2103)<\/td>\n<td>l\/h<\/td>\n<td>2.4<\/td>\n<\/tr>\n<tr>\n<td>PH\u503c<\/td>\n<td>-<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u6c34\u50a8\u7f50<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6709\u6548\u5bb9\u91cf<\/td>\n<td>L<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6e29\u5ea6<\/td>\n<td>\u00b0C<\/td>\n<td>40-60<\/td>\n<\/tr>\n<tr>\n<td>\u4ea7\u7387\u91cf(\u25b3t=25K)<\/td>\n<td>l\/min<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u70ed<\/td>\n<td>kWh\/m\u00b3<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b(Pmax)<\/td>\n<td>bar<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u7c7b\u522b(\u5929\u7136\u6c1413T\u6216LPG=40\u2103)<\/td>\n<td>-<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<td><strong>\u80fd\u8017<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u529f\u8017(\u5f85\u673a)<\/td>\n<td>W<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u529f\u8017(\u4f9b\u6696)<\/td>\n<td>W<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u4fdd\u62a4\u88c5\u7f6e<\/td>\n<td>-<\/td>\n<td>(IP40)<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u5faa\u73af\u6cf5\u6700\u5927\u529f\u7387(W)<\/td>\n<td>\u00b0C<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u6700\u5927\u8fd0\u884c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u56de\u6c34\u6700\u9ad8\u6e29\u5ea6(\u4e0a\u9650)<\/td>\n<td>\u00b0C<\/td>\n<td>0-40<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u5305\u62ec\u9644\u4ef6)<\/td>\n<td>kg<\/td>\n<td>130<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>1820x600x670<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 id=\"GC8700\" class=\"wp-block-heading\">CONDENS 8700I W \u2014 \u51b7\u51dd\u5f0f\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5fb7\u56fd\u8fdb\u53e3\uff0c\u6c22\u80fd\u5c31\u7eea\uff1b\u4e13\u4e3a\u522b\u5885\/\u5927\u5e73\u5c42\u9ad8\u7aef\u7528\u6237\u5b9a\u5236<\/li>\n<li><strong>Slogan<\/strong>\uff1a\u70ed\u6c34\u5927\u5347\u4f4d \u91c7\u6696\u6d17\u6d74\u53cc\u4eab\u53d7<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u91d1\u5c5e\u7ea4\u7ef4\u9884\u7f6e\u5f0f\u71c3\u70e7\u5668<\/strong>\uff1a\u66f4\u8010\u7528\uff0c\u5012\u7f6e\u706b\u70ae\uff0c\u8150\u8680\u6027\u51b7\u51dd\u6c34\u4e0d\u4f1a\u63a5\u89e6\u71c3\u70e7\u5668\uff0c\u589e\u957f\u5bff\u547d<\/li>\n<li><strong>\u94f8\u7845\u94dd\u4e3b\u70ed\u4ea4\u6362\u5668<\/strong>\uff1a\u6b27\u6d32\u5236\u9020\u4e13\u5229\uff0c\u7845\u94dd\u5408\u91d1\u4e00\u4f53\u94f8\u9020\u6210\u578b\uff0c\u65e0\u710a\u70b9\uff0c\u65e0\u60e7\u6f0f\u6c34\u98ce\u9669<\/li>\n<li><strong>\u6ee1\u8db315\u5e74\u8bbe\u8ba1\u5bff\u547d\u73af\u4fdd\u6750\u6599\u8981\u6c42<\/strong><\/li>\n<li>\u7ea6108%\u8d85\u9ad8\u70ed\u6548\u7387\uff08\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a\uff09<\/li>\n<li>\u535a\u4e16\u6052\u6e29\u63a7\u7130\u6280\u672f + \u5ba4\u5916\u8865\u507f\u529f\u80fd<\/li>\n<li><strong>22L\u5927\u5347\u4f4d\u6ee1\u8db3\u53cc\u536b\u70ed\u6c34\u540c\u65f6\u4f7f\u7528\u9700\u6c42<\/strong>\uff1b3\u661f\u9ad8\u70ed\u6c34\u54c1\u8d28<\/li>\n<li>\u5feb\u901f\u62c6\u5378-20s \u76f4\u8fbe\u673a\u5668\u5185\u90e8\uff1b\u6781\u7b80\u7ef4\u62a4-\u7eff\u8272\u4ea4\u4e92\u90e8\u4ef6\uff0c\u6781\u7ebf\u5feb\u901f\u9501\u5b9a\u62c6\u5378\uff1b\u7279\u522b\u8bbe\u8ba1\u7684\u827e\u74e6\u91cc\u8c03\u8282\u88c5\u7f6e\uff0c\u65e0\u9700\u7e41\u7410\u8c03\u8bd5<\/li>\n<li><strong>50\u4f59\u91cd\u5b89\u5168\u4fdd\u969c<\/strong>\uff0c\u4e13\u4e1a\u5b88\u62a4\uff0c\u53ef\u9760\u8010\u7528<\/li>\n<li><strong>\u9759\u8c27\u8fd0\u884c<\/strong>\uff1a\u7279\u6b8a\u7ed3\u6784\u8bbe\u8ba1\uff0c\u963b\u9694\u566a\u97f3\uff0c\u8212\u4eab\u9759\u8c27<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>CONDENS 8700I W \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1GBO24-GC8700WM 24kW-C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1GBO34-GC8700WM 35kW-C<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>23.8-24.5<\/td>\n<td>33.0-33.5<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>21.3-21.4<\/td>\n<td>29.3-29.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>28.0<\/td>\n<td>38.0<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa\u8303\u56f4<\/td>\n<td>kW<\/td>\n<td>5.1-5.4<\/td>\n<td>6.1-6.8<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8d1f\u8377<\/td>\n<td>kW<\/td>\n<td>31.4-31.6<\/td>\n<td>34.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u7a7a\u6c14\u91cf(\u5929\u7136\u6c1413T)<\/td>\n<td>m\u00b3\/h<\/td>\n<td>6.3<\/td>\n<td>8.3<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa<\/td>\n<td>1,500-3,000<\/td>\n<td>1,500-3,000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u8def<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6d41\u91cf\u8bbe\u5b9a\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>10-88<\/td>\n<td>10-88<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u989d\u5b9a\u8303\u56f4<\/td>\n<td>L<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u4ea7\u6c34\u91cf(\u0394t=25K)<\/td>\n<td>kg\/min<\/td>\n<td>22.0<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51fa\u6c34\u6e29\u5ea6\u8bbe\u7f6e\u8303\u56f4<\/td>\n<td>\u00b0C<\/td>\n<td>35-60<\/td>\n<td>35-60<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf\u914d\u7f6e<\/td>\n<td>kg\/min<\/td>\n<td>51.9<\/td>\n<td>55-60<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u51fa\u6c34\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u51fa\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<\/tr>\n<tr>\n<td><strong>NOx\u7b49\u7ea7<\/strong><\/td>\n<td>mg\/kWh<\/td>\n<td>5<\/td>\n<td>\u2264120<\/td>\n<\/tr>\n<tr>\n<td>\u6392\u70df\u53e3<\/td>\n<td>mm<\/td>\n<td>60\/130<\/td>\n<td>60\/130<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90<\/td>\n<td>AC..V<\/td>\n<td>~220V\/50Hz<\/td>\n<td>~220V\/50Hz<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u5bb9<\/td>\n<td>W<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>50<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>840x370x365<\/td>\n<td>840x430x365<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"gdxl1\" class=\"wp-block-heading\">\u4e94\u3001\u9ad8\u7aef\u7cfb\u5217<\/h2>\n<h3 id=\"GC7100\" class=\"wp-block-heading\">CONDENS 7100 W \u2014 \u5fb7\u56fd\u97e6\u5c14\u7459\u5de5\u5382\u539f\u88c5\u8fdb\u53e3<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5168\u7403\u9500\u91cf\u8d85\u8fc7160\u4e07\u53f0\uff1b\u5de5\u4e1a4.0\u5236\u9020\u5de5\u5382\uff0c\u751f\u4ea7\u65b9\u5f0f\u5168\u7ebf\u667a\u80fd\u5316\uff1b\u6570\u5b57\u5316\u8ddf\u8e2a\u751f\u4ea7\u7ec6\u8282\uff0c\u81ea\u52a8\u6545\u969c\u6392\u67e5\uff0c\u54c1\u8d28\u6709\u4fdd\u969c<\/li>\n<li><strong>\u516b\u5927\u6838\u5fc3\u6280\u672f<\/strong>\uff08\u89c1\u4e0a\u6587\u51b7\u51dd\u6280\u672f\u6838\u5fc3\u90e8\u5206\uff09<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>CONDENS 7100 W \u6280\u672f\u53c2\u6570\u8868\uff08\u5b8c\u6574\u7248\uff09<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 24<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 26\/30C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W MC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 35<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 37C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 39<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W EM<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>27.4<\/td>\n<td>28.7<\/td>\n<td>29.8<\/td>\n<td>32.5<\/td>\n<td>35.4<\/td>\n<td>37.4<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>26.1<\/td>\n<td>24.5<\/td>\n<td>29.4<\/td>\n<td>34.1<\/td>\n<td>34.1<\/td>\n<td>37.2<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>27.4<\/td>\n<td>28.2<\/td>\n<td>30.4<\/td>\n<td>36.4<\/td>\n<td>35.4<\/td>\n<td>38.4<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>8.5<\/td>\n<td>9.3<\/td>\n<td>9.4<\/td>\n<td>14.5<\/td>\n<td>11.5<\/td>\n<td>14.5<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>30.0<\/td>\n<td>30.0<\/td>\n<td>30.0<\/td>\n<td>34.3<\/td>\n<td>34.3<\/td>\n<td>34.3<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf\u8303\u56f4<\/td>\n<td>kW<\/td>\n<td>30.4<\/td>\n<td>30.4<\/td>\n<td>30.4<\/td>\n<td>35.4<\/td>\n<td>35.4<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c14(L3T)<\/td>\n<td>m\u00b3\/h<\/td>\n<td>3.9<\/td>\n<td>3.2<\/td>\n<td>3.2<\/td>\n<td>3.7<\/td>\n<td>4.1<\/td>\n<td>4.1<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa\/h<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u8212\u9002\u6c34\u6d41\u91cf<\/td>\n<td>L<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6d41\u91cf(\u0394t=25K)<\/td>\n<td>Ag\/min<\/td>\n<td>-<\/td>\n<td>16.2<\/td>\n<td>18.2<\/td>\n<td>-<\/td>\n<td>23.0<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6d41\u91cf\u8303\u56f4<\/td>\n<td>\u00b0C<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b(Pmax)<\/td>\n<td>bar<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>NOx\u7b49\u7ea7<\/td>\n<td>\u2103<\/td>\n<td>51\/52<\/td>\n<td>59\/53<\/td>\n<td>51\/52<\/td>\n<td>60\/53<\/td>\n<td>69\/53<\/td>\n<td>69\/53<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6392\u70df\u53e3<\/td>\n<td>mm<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u6c34\u91cf(\u0394t=30\u00b0C)<\/td>\n<td>l\/h<\/td>\n<td>2.2<\/td>\n<td>2.4<\/td>\n<td>3.4<\/td>\n<td>2.9<\/td>\n<td>3.5<\/td>\n<td>3.5<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u5bb9<\/td>\n<td>W<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>-<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 class=\"wp-block-heading\">\u6b27\u6d32\u8d35\u65cf \u2014 \u51b7\u51dd\u5f0f\u71c3\u6c14\u6696\u6d74\u4e24\u7528\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u8d8a\u7ea7\u84dd\u7ed2\u7130 \u51b7\u51dd\u5927\u70ed\u6c34<\/li>\n<li><strong>\u70ed\u6c34\u7cfb\u7edf\u4eae\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u6dfb\u5347\u6709\u91cf \u53cc\u536b\u65e0\u5fe7<\/strong>\uff1a16kg\/min\u4ea7\u70ed\u6c34\u91cf\uff0c\u91cd\u65b0\u5b9a\u4e49\u535a\u4e1625kW\u70ed\u6c34\u6807\u51c6\uff1b25kW\u91c7\u6696\u7089\u9001\u53d116kg\/min\u70ed\u6c34\u91cf\uff0c\u4ea7\u6c34\u7387\u8d85\u5e45\u589e\u540c\u5e73\u53f025%\uff0c\u8f83\u4e0a\u4e00\u4ee3\"\u70ed\u6c34\u91cf\u63d0\u534725%\"<\/li>\n<li><strong>\u83b7\u5f97\u6b27\u6d32\u4e09\u661f\u8212\u9002\u70ed\u6c34\u8ba4\u8bc1<\/strong><\/li>\n<li><strong>CHG\u6c34\u529b\u7ec4\u4ef6\u5168\u9762\u5347\u7ea7<\/strong>\uff1a\u677f\u5f0f\u6362\u70ed\u5668\u4f53\u79ef\u8f83\u4e0a\u4e00\u4ee3\u589e\u52a030%<\/li>\n<li><strong>\u9ad8\u5ea6\u6da1\u8f6e\u6d41\u91cf\u4f20\u611f\u5668<\/strong>\uff1a\u5185\u7f6e\u7075\u654f\u7684\u78c1\u8f6c\u5b50\uff0c\u5728\u6781\u5c0f\u6d41\u91cf\u4e0b\u4e5f\u80fd\u8f6c\u52a8\uff0c\u9ad8\u7075\u654f\u4f20\u611f\u5668\u53ef\u611f\u77e5\u6781\u5c0f\u7684\u6c34\u6d41\u53d8\u5316<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u71c3\u70e7\u7cfb\u7edf<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5546\u7528\u71c3\u70e7\u5668 \u66f4\u8010\u7528\uff08\u84dd\u8574\u706b\u7130\uff0c\u5c0f\u4f53\u79ef\u5927\u80fd\u91cf\uff09<\/li>\n<li>\u9ad8\u80fd\u6548 \u66f4\u8282\u80fd\uff08\u5168\u9884\u6df7\u5408\u51b7\u51dd\u71c3\u70e7\u6280\u672f\uff0c\u667a\u80fd\u8c03\u8282\u70ed\u8d1f\u8377\uff0c\u7ea6108%\u8d85\u9ad8\u70ed\u6548\u7387\uff09<\/li>\n<li>\u65e0\u710a\u70b9 \u66f4\u575a\u56fa\uff08\u535a\u4e16\u4e13\u5229WB5\u7845\u94dd\u5408\u91d1\u6362\u70ed\u5668\uff0c\u4e00\u4f53\u6210\u578b\uff09<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u6b27\u6d32\u8d35\u65cf \u6280\u672f\u53c2\u6570\u8868<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">25kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">25kW \u5546\u5c45\u4e24\u7528<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u5546\u5c45\u4e24\u7528<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u63cf\u8ff0<\/strong><\/td>\n<td>L1JF020\/1(DNW020\/1)<\/td>\n<td>L1JF020Z1\/DNZ020\/1A<\/td>\n<td>L1JF034\/DNZ034<\/td>\n<td>L1JF034Z1(DNW034\/1)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8d1f\u8377<\/td>\n<td>kW<\/td>\n<td>20.3<\/td>\n<td>27.4<\/td>\n<td>36.4<\/td>\n<td>39.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>6.2<\/td>\n<td>6.5<\/td>\n<td>9.2<\/td>\n<td>9.2<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>20.3<\/td>\n<td>27.4<\/td>\n<td>36.5<\/td>\n<td>39.4<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u6392\u70df<\/td>\n<td>-<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68072\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u6c34\u91cf<\/td>\n<td>W<\/td>\n<td>115<\/td>\n<td>115<\/td>\n<td>150<\/td>\n<td>175<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u57fa\u672c\u8017\u7535\u91cf<\/td>\n<td>W<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<td>93<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u6700\u5927\u9002\u7528\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u70ed\u529b<\/td>\n<td>L<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u6700\u5927\u4ea7\u51fa\u80fd\u529b<\/td>\n<td>kW<\/td>\n<td>36<\/td>\n<td>-<\/td>\n<td>38<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u5236\u70ed\u4ea7\u6c34\u91cf(\u0394t=25K)<\/td>\n<td>kg\/min<\/td>\n<td>16.2<\/td>\n<td>16.2<\/td>\n<td>21<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-60<\/td>\n<td>40-60<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u4f9b\u6c34\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u51fa\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.2<\/td>\n<td>0.2<\/td>\n<td>0.2<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>53<\/td>\n<td>58<\/td>\n<td>62<\/td>\n<td>64<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>850x455x350<\/td>\n<td>850x455x320<\/td>\n<td>850x450x320<\/td>\n<td>850x450x320<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"dgyzjk\" class=\"wp-block-heading\">\u516d\u3001\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\u7cfb\u5217<\/h2>\n<h3 id=\"G8550\" class=\"wp-block-heading\">G8550I W \u2014 \u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u5168\u6c14\u5019\u6052\u6e29 \u9759\u4eab8\u7cfb\u8c6a\u534e<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u5168\u6c14\u5019\u6052\u6e29\u6280\u672f<\/strong>\uff08\u56db\u5b63\u8212\u723d\u6d17\u6fa1\uff09\uff1a\n<ul class=\"wp-block-list\">\n<li>\u6f6e\u6c50\u706b\u6392\uff0c\u5206\u89c4\u71c3\u70e7Plus<\/li>\n<li>\u8fdb\u51fa\u6c34\u53cc\u6e29\u611f\uff0c\u7cbe\u51c6\u8c03\u8282<\/li>\n<li>\u535a\u4e16\u4e13\u5229\u6052\u6e29\u6280\u672f<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u535a\u4e16\u7b2c4\u4ee3\u70ed\u80fd\u82af<\/strong>\uff1aEMS2.0\u5168\u65b0\u81ea\u7814\u7b97\u6cd5\uff0c\u806a\u660e\u7701\u6c14\uff1b\u53ef\u4e0e\u535a\u4e16\u667a\u80fd\u63a7\u5236\u5668MR\u7cfb\u5217\u7b49\u5339\u914d<\/li>\n<li><strong>\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3<\/strong>\uff1a\u667a\u80fd\u5236\u90204.0\u4ea7\u7ebf<\/li>\n<li><strong>\u535a\u4e16DNA\u8bbe\u8ba1\u5916\u89c2<\/strong>\uff08\u7d27\u51d1\u5c0f\u5de7\u89e6\u611f\u64cd\u63a7\uff09\uff1a\u667a\u80fd\u81ea\u52a8\u53164.0\u4ea7\u7ebf<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>G8550i W \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YPS-G8550W 24C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YP-G8550WN2C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YPP-G8550WN2<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YPL-G8550WN2<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>26.4<\/td>\n<td>20.7<\/td>\n<td>26.4<\/td>\n<td>20.7<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>28<\/td>\n<td>28<\/td>\n<td>28<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>3.8<\/td>\n<td>3.9<\/td>\n<td>3.8<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf\u8303\u56f4<\/td>\n<td>kW<\/td>\n<td>26.6<\/td>\n<td>26.6<\/td>\n<td>26.6<\/td>\n<td>26.6<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c14(L3T)<\/td>\n<td>m\u00b3\/h<\/td>\n<td>26.4(12T)<\/td>\n<td>26.7(12T)<\/td>\n<td>26.4(12T)<\/td>\n<td>26.7(12T)<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2000<\/td>\n<td>2000<\/td>\n<td>2000<\/td>\n<td>2000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u5bb9<\/td>\n<td>W<\/td>\n<td>190<\/td>\n<td>190<\/td>\n<td>190<\/td>\n<td>190<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>682x367x776<\/td>\n<td>682x367x776<\/td>\n<td>682x367x778<\/td>\n<td>682x367x778<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">*\u6570\u636e\u6765\u6e90\u4e8eG8550WN2\u89c4\u683c\u4e66<\/p>\n<\/blockquote>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"jdpzxl\" class=\"wp-block-heading\">\u4e03\u3001\u7ecf\u5178\u54c1\u8d28\u7cfb\u5217<\/h2>\n<h3 class=\"wp-block-heading\">\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248 \u2014 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u7ecf\u5178\u54c1\u8d28\uff0c\u65e0\u5fe7\u4e4b\u9009<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u7ea6<strong>93%<\/strong>\u8d85\u9ad8\u70ed\u6548\u7387\uff0c\u8282\u7701\u71c3\u6c14\u5f00\u652f<\/li>\n<li>\u4f4e\u566a\u8fd0\u884c\uff08\u53cc\u901f\u98ce\u673a+\u53d8\u9891\u6c34\u6cf5\uff0c\u53ef\u4f20\u673a\u5668\u4f4e\u901f\u8fd0\u8f6c\uff09<\/li>\n<li>\u5feb\u51fa\u5145\u6c9b\u70ed\u6c34\uff08\u5145\u6d74\u70ed\u6c34\u4f9b\u5e94\uff0c\u6ee1\u8db3\u5927\u82b1\u6d12\u6d41\u91cf\u8981\u6c42\uff09<\/li>\n<li><strong>\u8d85\u8fc7100\u4e07\u53f0<\/strong>\u5168\u7403\u5b89\u5168\u8fd0\u884c\uff08\u81ea2001\u5e74\u5728\u6b27\u6d32\u4e0a\u5e02\uff0c\u5168\u7403\u9500\u91cf\u7d2f\u8ba1\u7a81\u7834100\u4e07\u53f0\uff09<\/li>\n<li><strong>10\u5e74<\/strong>\u7545\u9500\u4e2d\u56fd\uff08\u622a\u81f32022\u5e7412\u6708\uff09<\/li>\n<li><strong>10\u9879<\/strong>\u91cd\u5b89\u5168\u4fdd\u969c\uff08\u4f9b\u70ed\u56de\u8def\u4f4e\u538b\u4fdd\u62a4\u3001\u70df\u6c14\u76d1\u6d4b\u5173\u95ed\u3001\u751f\u6d3b\u70ed\u6c34\u6c34\u91cf\u76d1\u6d4b\u3001\u71c3\u6c14\u5b89\u5168\u4fdd\u62a4\u3001\u5b89\u5168\u6cc4\u538b\u4fdd\u62a4\u3001\u4f9b\u6696\u6c34\u6e29\u76d1\u6d4b\u3001\u6545\u969c\u76d1\u6d4b\/\u91cd\u9501\u3001\u8d85\u6e29\u4fdd\u62a4\u3001\u71c3\u70e7\u5ba4\u76d1\u6d4b\u3001\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\u76d1\u6d4b\uff09<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\" id=\"ZWCW24\"><strong>\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248 \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">24kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">24kW \u7cfb\u5217\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">28kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">28kW \u7cfb\u5217\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u7cfb\u5217\u7089<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u63cf\u8ff0<\/td>\n<td>L1JP27-ZWCW24<\/td>\n<td>L1JP27-ZWCW24G<\/td>\n<td>L1JP23-ZWCW28<\/td>\n<td>L1JP23-ZWCW28G<\/td>\n<td>L1JP23-ZWCW35<\/td>\n<td>L1JP23-ZWCW35G<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u79cd\u7c7b<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u5165(\u91c7\u6696)<\/td>\n<td>kW<\/td>\n<td>26.7<\/td>\n<td>26.7<\/td>\n<td>31.3<\/td>\n<td>31.3<\/td>\n<td>38.3<\/td>\n<td>38.3<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa(\u4e24\u7528)<\/td>\n<td>kW<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>28.1<\/td>\n<td>28.1<\/td>\n<td>34.9<\/td>\n<td>34.9<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u9ad8\u56de\u6c34\u6e29\u5ea6<\/td>\n<td>\u2103<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u5de5\u4f5c\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u542b\u5305\u88c5)<\/td>\n<td>kg<\/td>\n<td>41<\/td>\n<td>41<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>46<\/td>\n<td>46<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 id=\"G7200W\" class=\"wp-block-heading\">G7\u955c\u9762\u7248 \u2014 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u6709\u989c\u6709\u54c1 \u5c3d\u5584\u9759\u7f8e \/ \u8ba9\u5149\u5f69\uff0c\u70b9\u4eae\u6e29\u6696\u751f\u6d3b\uff01<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5149\u5f71\u73bb\u7483\u9762\u677f\uff0c\u7edd\u7f8e\u6297\u6cb9\u6c61<\/li>\n<li>\u4e00\u7ea7\u9759\u97f3\uff0c\u9759\u4eab\u6e29\u6696<\/li>\n<li>\u4e13\u5229\u63a7\u6e29\u6280\u672f\uff0c\u6781\u901f\u54cd\u5e94\uff0c\u6052\u6e29\u8212\u9002<\/li>\n<li>\u4e13\u5229\u6392\u70df\u8bbe\u8ba1\uff0c\u6297\u5f3a\u98ce\u7b97\u6cd5\uff0c\u4e0d\u60e7\u5f3a\u98ce\u4fb5\u88ad\uff0c\u6e29\u6696\u4e0d\u505c<\/li>\n<li>\u642d\u914dMR\u7cfb\u5217\u667a\u80fd\u6e29\u63a7\uff0cwifi\u64cd\u4f5c\uff0c\u7701\u5fc3\u7701\u6c14<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>G7\u955c\u9762\u7248\u6280\u672f\u53c2\u6570\u5bf9\u6bd4<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">G7\u955c\u9762\u7248 24kW<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">G7\u955c\u9762\u7248 28kW<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u578b\u53f7<\/td>\n<td><\/td>\n<td>L1JP27-G7200W 24 CG<\/td>\n<td>L1JP31-G7200W 28 CG<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u79cd\u7c7b<\/td>\n<td><\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<\/tr>\n<tr>\n<td><strong>\u52a8\u529b<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>24<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5927\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>26.6<\/td>\n<td>31.1<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>7.4<\/td>\n<td>8.9<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5c0f\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>8.6<\/td>\n<td>10.3<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u6700\u5927\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>26.6<\/td>\n<td>31.1<\/td>\n<\/tr>\n<tr>\n<td>\u80fd\u6548\u7b49\u7ea7<\/td>\n<td><\/td>\n<td>\u56fd\u68072\u7ea7<\/td>\n<td>\u56fd\u68072\u7ea7<\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u7535\u529b\u7387<\/td>\n<td>W<\/td>\n<td>&lt;110<\/td>\n<td>&lt;120<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u51fa\u6c34\u6e29\u5ea6\u8bbe\u7f6e\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-82<\/td>\n<td>40-82<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u7cfb\u7edf\u5141\u8bb8\u7684\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u81a8\u80c0\u6c34\u7bb1<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u538b\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.05<\/td>\n<td>0.05<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u5bb9\u79ef<\/td>\n<td>L<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u79f0\u4ea7\u6c34\u901f\u7387(\u0394t=25K)<\/td>\n<td>kg\/min<\/td>\n<td>13.0<\/td>\n<td>16.0<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51fa\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>35-60<\/td>\n<td>35-60<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u7cfb\u7edf\u4f7f\u7528\u6c34\u538b<\/td>\n<td>MPa<\/td>\n<td>0.03-1<\/td>\n<td>0.03-1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b(\u5929\u7136\u6c1412T)<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e00\u822c\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u6c34\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u542b\u5305\u88c5)<\/td>\n<td>kg<\/td>\n<td>33<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u539a)<\/td>\n<td>mm<\/td>\n<td>707.5x400x312<\/td>\n<td>707.5x400x312<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 id=\"G7350\" class=\"wp-block-heading\">G7350i W\uff08G7 Pro\uff09\u2014 \u5e38\u89c4\u58c1\u6302\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u8ba9\u5149\u5f69\uff0c\u70b9\u4eae\u6e29\u6696\u751f\u6d3b\uff01<\/li>\n<li><strong>\u4ea7\u54c1\u7cfb\u5217<\/strong>\uff1aG7 Pro\uff08\u8d85\u6052\u6e297\u7cfb\uff09<\/li>\n<li><strong>\u54c1\u724c\u7406\u5ff5<\/strong>\uff1aLIVE LIKE A BOSCH<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">\u4e3b\u8981\u529f\u80fd\u7279\u70b9<\/h4>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>\u4e13\u5229\u5206\u6bb5\u71c3\u70e7\u6280\u672f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u5206\u6bb5\u71c3\u70e7\u706b\u6392 + \u53cc\u71c3\u6c14\u9600\u8bbe\u8ba1<\/li>\n<li>\u8fdb\u51fa\u6c34\u53cc\u6e29\u611f\uff1a\u53cc\u5411\u76d1\u6d4b\u6c34\u6e29<\/li>\n<li>\u70ed\u6c34\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff1a4kW<\/li>\n<li>\u5bbd\u5e45\u53d8\u9891\u8c03\u8282\uff1a\u9002\u5e94\u4e0d\u540c\u5b63\u8282\u9700\u6c42<\/li>\n<li>\u56db\u5b63\u6052\u6e29\u6c90\u6d74\u4f53\u9a8c\uff08\u590f\u5b63\u8212\u723d\u7545\u5feb\uff0c\u51ac\u5b63\u6e29\u6696\u6f8e\u6e43\uff09<\/li>\n<li>\u53d1\u660e\u4e13\u5229\u7533\u8bf7\u53f7\uff1a202010874856.7 \/ 202010230415.3<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u4e00\u7ea7\u9759\u97f3\u8ba4\u8bc1<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u72ec\u7279\u9694\u97f3\u4ed3\u8bbe\u8ba1<\/li>\n<li>\u51cf\u9707\u53d8\u901f\u98ce\u673a<\/li>\n<li>\u5c0f\u8d1f\u8377\u4f4e\u901f\u9759\u97f3\u8fd0\u884c<\/li>\n<li>\u6743\u5a01\u4e00\u7ea7\u9759\u97f3\u8ba4\u8bc1<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u5149\u5f71\u73bb\u7483\u9762\u677f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u6e29\u953b\u9020\u955c\u9762\u73bb\u7483<\/li>\n<li>\u5bbd\u5ea6\u4ec5400mm\uff1a\u5c0f\u5de7\u4f53\u79ef\uff0c\u7075\u6d3b\u5b89\u88c5<\/li>\n<li>\u591a\u8272\u53ef\u9009<\/li>\n<li>\u5149\u5f71\u8d28\u611f\uff0c\u6297\u6cb9\u6c61\u8bbe\u8ba1<\/li>\n<li>\u9762\u677f\u6613\u6e05\u6d01\uff0c\u8f7b\u677e\u88c5\u5165\u6a71\u67dc<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u4e2d\u6587\u89e6\u5c4f\u63a7\u5236<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u4e2d\u6587\u754c\u9762 + LED\u663e\u793a\u5c4f<\/li>\n<li>\u89e6\u6478\u5c4f\u5e55<\/li>\n<li>160\u00b0\u53ef\u89c6\u89d2\uff1a\u8fd0\u884c\u72b6\u6001\u6e05\u6670\u663e\u793a<\/li>\n<li>\u4e00\u89e6\u5373\u63a7\uff0c\u64cd\u4f5c\u7b80\u5355\u6613\u4e0a\u624b<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u5916\u89c2\u8bbe\u8ba1<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u535a\u4e16DNA\u5320\u5fc3\u7f8e\u5b66\u8bbe\u8ba1<\/li>\n<li>\u535a\u4e16\u5706\u73af\u53ca\u5706\u5f62\u4eba\u673a\u4ea4\u4e92\u754c\u9762\u8bbe\u8ba1 - \u767e\u642d\u88c5\u4fee\u98ce\u683c<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h4 class=\"wp-block-heading\">\u6280\u672f\u4eae\u70b9\u603b\u7ed3<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u4f18\u52bf<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5177\u4f53\u63cf\u8ff0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u6052\u6e29\u6280\u672f<\/td>\n<td>\u4e13\u5229\u5206\u6bb5\u71c3\u70e7\uff0c\u56db\u5b63\u6052\u6e29\u6c90\u6d74<\/td>\n<\/tr>\n<tr>\n<td>\u9759\u97f3\u8fd0\u884c<\/td>\n<td>\u4e00\u7ea7\u9759\u97f3\u8ba4\u8bc1\uff0c\u9694\u97f3\u4ed3+\u51cf\u9707\u98ce\u673a<\/td>\n<\/tr>\n<tr>\n<td>\u65f6\u5c1a\u5916\u89c2<\/td>\n<td>\u5149\u5f71\u73bb\u7483\u9762\u677f\uff0c400mm\u7ea4\u8584\u5bbd\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u667a\u80fd\u64cd\u63a7<\/td>\n<td>\u4e2d\u6587\u89e6\u5c4f\uff0c160\u00b0\u5e7f\u89c6\u89d2\u663e\u793a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">\u4ea7\u54c1\u578b\u53f7<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>L1P27-G7350iW 24CD<\/strong>\uff0824KW\uff0c\u9002\u7528\u9762\u79ef80-120\u33a1\uff09<\/li>\n<\/ul>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"jjsyxl\" class=\"wp-block-heading\">\u516b\u3001\u7ecf\u6d4e\u5b9e\u7528\u7cfb\u5217<\/h2>\n<h3 id=\"G6300W\" class=\"wp-block-heading\">G6300W \u2014 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u4e0d\u60e7\u4e25\u5bd2 \u6e29\u6696\u6709\u4f60<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u6781\u7aef\u73af\u5883\u901a\u7528\uff1a\u4e13\u4e3a<strong>\u4e2d\u56fd\u5e02\u573a<\/strong>\u8bbe\u8ba1\u7684G6300W\uff0c\u9002\u7528\u4e8e\u5317\u90e8\u4e25\u5bd2\u5730\u533a\u7684\u6c14\u5019\u6761\u4ef6<\/li>\n<li>\u5c0f\u8eab\u6750\u3001\u5927\u70ed\u6c34\uff1a\u517c\u5177\u8282\u80fd\u8212\u9002\uff0cG6300W\u53ef\u5728\u8f83\u5c0f\u91c7\u6696\u8d1f\u8377\u4e0b\u8fd0\u884c\uff0c\u4ee5\u8282\u7ea6\u71c3\u6c14<\/li>\n<li>\u8fd0\u884c\u566a\u97f3\u4ec5<strong>48dB(A)<\/strong><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>G6300W \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1JPB-G6300W 18\/18 CB<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1JP34-G6300W 22\/24 CG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>18<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>17.9<\/td>\n<td>24.4<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>6.4<\/td>\n<td>7.4<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>6.3<\/td>\n<td>8.6<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c14<\/td>\n<td>-<\/td>\n<td>\u5929\u7136\u6c1412T<\/td>\n<td>\u5929\u7136\u6c1412T<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u989d\u5b9a\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-82<\/td>\n<td>40-82<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u80c0\u6c34\u7bb1\u5bb9\u79ef<\/td>\n<td>L<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u4ea7\u6c34\u91cf(\u0394t=25K)<\/td>\n<td>kg\/min<\/td>\n<td>10<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51fa\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>35-60<\/td>\n<td>35-60<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u51fa\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e00\u822c\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u542b\u5305\u88c5)<\/td>\n<td>kg<\/td>\n<td>28<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u539a)<\/td>\n<td>mm<\/td>\n<td>700x400x290<\/td>\n<td>700x400x290<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 id=\"G6100W\" class=\"wp-block-heading\">G6100W \u2014 \u8fdb\u53e3\u6b3e\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u4ea7\u54c1\u7c7b\u578b<\/strong>\uff1a\u5e38\u89c4\u58c1\u6302\u7089<\/li>\n<li><strong>\u4ea7\u5730<\/strong>\uff1a\u6b27\u6d32\u8fdb\u53e3<\/li>\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5fb7\u7cfb\u54c1\u8d28\uff0c\u4e13\u4e3a\u4e2d\u56fd\u5e02\u573a\u5b9a\u5236<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">\u6838\u5fc3\u529f\u80fd\u7279\u70b9<\/h4>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>\u7a33\u5b9a\u53ef\u9760\u6027<\/strong>\uff1a\u5373\u4f7f\u5728\u4e25\u5bd2\u73af\u5883\u6e29\u5ea6\u4e0b\u4f9d\u65e7\u7a33\u5b9a\u8fd0\u884c\uff0c\u6839\u636e\u4e2d\u56fd\u6c34\u8d28\u3001\u71c3\u6c14\u6210\u5206\u3001\u4e0d\u540c\u533a\u57df\u6c14\u5019\u7279\u70b9\u91cf\u8eab\u5b9a\u5236<\/li>\n<li><strong>\u9ad8\u6548\u8282\u80fd<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u4f9b\u6696\u70ed\u6548\u7387\uff1a\u989d\u5b9a\u70ed\u8d1f\u8377\u4e0b\u6700\u9ad8\u53ef\u8fbe<strong>92%<\/strong><\/li>\n<li>\u70ed\u6c34\u70ed\u6548\u7387\uff1a\u989d\u5b9a\u70ed\u8d1f\u8377\u4e0b\u6700\u9ad8\u53ef\u8fbe<strong>92%<\/strong><\/li>\n<li>\u6d4b\u8bd5\u578b\u53f7\uff1aL1P31-G6100W 28 CG\uff08\u6570\u636e\u6765\u6e90\uff1a\u7b2c\u4e09\u65b9\u68c0\u6d4b\u673a\u6784\uff09<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u8212\u9002\u70ed\u6c34<\/strong>\uff1a\u677f\u5f0f\u6362\u70ed\u5668\u4fdd\u969c\u8212\u9002\u7684\u5373\u65f6\u751f\u6d3b\u70ed\u6c34<\/li>\n<li><strong>\u667a\u80fd\u63a7\u5236<\/strong>\uff1a\u53ef\u7ed3\u5408\u535a\u4e16MR100\u3001OT\u7cfb\u5217\u63a7\u5236\u5668\u4f7f\u7528\uff0c\u8282\u80fd\u4fbf\u6377<\/li>\n<li><strong>\u64cd\u4f5c\u4fbf\u6377<\/strong>\uff1a\u80cc\u5149\u8bbe\u8ba1LCD\u663e\u793a\u5c4f\uff0c\u4f7f\u7528\u8212\u9002\u65b9\u4fbf<\/li>\n<li><strong>\u9759\u97f3\u8fd0\u884c<\/strong>\uff1a\u8ba9\u6e29\u6696\u6084\u7136\u800c\u81f3<\/li>\n<li><strong>\u4fbf\u4e8e\u5b89\u88c5\u4e0e\u7ef4\u62a4<\/strong>\uff1a\u7d27\u51d1\u5c3a\u5bf8\uff0c\u5c0f\u7a7a\u95f4\u4e5f\u53ef\u5b89\u88c5\uff1b\u6c34\u529b\u7ec4\u4ef6\u6210\u719f\uff0c\u65b9\u4fbf\u8fde\u63a5\uff1b\u6240\u6709\u7ec4\u4ef6\u4f7f\u7528\u6807\u51c6\u5de5\u5177\u5373\u53ef\u8f7b\u677e\u62c6\u5378<\/li>\n<\/ol>\n<h4 class=\"wp-block-heading\">\u4e3b\u8981\u7ec4\u4ef6\u5217\u8868<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ec4\u4ef6\u540d\u79f0<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ec4\u4ef6\u540d\u79f0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u98ce\u538b\u5f00\u5173<\/td>\n<td>10<\/td>\n<td>\u6cf5\u8f6c\u901f\u5f00\u5173<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u5b89\u5168\u9650\u6e29\u5668<\/td>\n<td>11<\/td>\n<td>\u6c34\u6cf5<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u677f\u5f0f\u6362\u70ed\u5668<\/td>\n<td>12<\/td>\n<td>\u71c3\u6c14\u9600<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u91c7\u6696\u51fa\u6c34\u6e29\u5ea6\u4f20\u611f\u5668<\/td>\n<td>13<\/td>\n<td>\u71c3\u70e7\u5ba4<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u63a7\u5236\u5668<\/td>\n<td>14<\/td>\n<td>\u677f\u5f0f\u6362\u70ed\u8212\u9002\u70ed\u6c34<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>\u98ce\u673a<\/td>\n<td>15<\/td>\n<td>\u5b89\u5168\u9600\uff08\u4f9b\u6696\u56de\u8def\uff09<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u5e26\u55b7\u5634\u7684\u71c3\u70e7\u5668\u6258\u67b6<\/td>\n<td>16<\/td>\n<td>\u81ea\u52a8\u6392\u6c14\u9600<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 id=\"C3260W\" class=\"wp-block-heading\">C3260W \u2014 \u51b7\u51dd\u5f0f\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u4ea7\u54c1\u540d\u79f0<\/strong>\uff1aCondens 3260 W\uff08\u4e5f\u79f0 C3260W \/ \u6b27\u6d32\u81f3\u81fbCondens 3260\uff09<\/li>\n<li><strong>\u4ea7\u54c1\u5b9a\u4f4d<\/strong>\uff1a\u667a\u63a7\u5168\u57df\"\u7eff\"\u52a8\u968f\u5fc3 \u2014 \u51b7\u51dd\u5f0f\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/li>\n<li><strong>\u80fd\u6548\u7b49\u7ea7<\/strong>\uff1a\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548<\/li>\n<li><strong>\u70ed\u6548\u7387<\/strong>\uff1a\u7ea6<strong>95% - 106%<\/strong>\uff0c\u6700\u9ad8\u53ef\u8fbe108%<\/li>\n<li><strong>\u8bbe\u8ba1\u5bff\u547d<\/strong>\uff1a10 - 15 \u5e74<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">\u5c3a\u5bf8\u89c4\u683c<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u9ad8\u5ea6<\/td>\n<td>655 mm<\/td>\n<\/tr>\n<tr>\n<td>\u5bbd\u5ea6<\/td>\n<td>395 mm<\/td>\n<\/tr>\n<tr>\n<td>\u6df1\u5ea6<\/td>\n<td>285 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">\u529f\u80fd\u7279\u70b9<\/h4>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>\u7a7a\u95f4\u9b54\u672f\u5e08 \u2014 \u5c0f\u5de7\u8bbe\u8ba1<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u5c0f\u5de7\u800c\u5f3a\u5927<\/li>\n<li>\u8f7b\u677e\u878d\u5165\u5404\u79cd\u5bb6\u5c45\u73af\u5883<\/li>\n<li>\u65e0\u8bba\u662f\u7d27\u51d1\u7a7a\u95f4\u8fd8\u662f\u5bbd\u655e\u6a71\u67dc\uff0c\u90fd\u80fd\u627e\u5230\u5408\u9002\u4f4d\u7f6e<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u535a\u4e16\u4e25\u82db\u54c1\u63a7 \u2014 \u54c1\u8d28\u4fdd\u8bc1<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u7279\u6b8a\u7ed3\u6784\u71c3\u70e7\u5668\uff1a\u8010\u7528\u4e4b\u9009<\/li>\n<li>\u5927\u901a\u5f84\u4e0d\u9508\u94a2\u4e3b\u70ed\u8bbe\u8ba1\uff1a\u4f4e\u5faa\u73af\u963b\u529b<\/li>\n<li>\u5bf9\u6c34\u8d28\u4e0d\u654f\u611f<\/li>\n<li>15\u5e74\u65e0\u5fe7\u5353\u8d8a\u96f6\u90e8\u4ef6\u4fdd\u969c<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u5168\u9884\u6df7\u51b7\u51dd\u71c3\u70e7\u6280\u672f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\u8ba4\u8bc1<\/li>\n<li>\u6839\u636e\u8d1f\u8377\u53d8\u5316\uff0c\u71c3\u70e7\u524d\u7a7a\u6c14\u548c\u71c3\u6c14\u7cbe\u51c6\u6bd4\u4f8b\u5145\u5206\u6df7\u5408<\/li>\n<li>\u7ea6108%\u8d85\u9ad8\u70ed\u6548\u7387<\/li>\n<li>\u71c3\u70e7\u66f4\u6e05\u6d01<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u5168\u57df\u81ea\u9002\u5e94\u7cfb\u7edf \u2014 \u7075\u6d3b\u667a\u80fd<\/strong><\/li>\n<\/ol>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u81ea\u9002\u5e94\u529f\u80fd<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8d1f\u8377\u8c03\u8282<\/td>\n<td>\u6839\u636e\u5b9e\u9645\u9700\u6c42\u81ea\u52a8\u8c03\u8282<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u673a\u8f6c\u901f<\/td>\n<td>\u6839\u636e\u8d1f\u8377\u9700\u6c42\u8c03\u8282\uff0c\u65f6\u523b\u4fdd\u6301\u9ad8\u6548\u71c3\u70e7\uff0c\u8282\u7ea6\u71c3\u6c14<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6c34\u6e29\u5ea6<\/td>\n<td>\u6839\u636e\u5ba4\u5916\u6e29\u5ea6\u8c03\u8282\uff0c\u8fdb\u4e00\u6b65\u8282\u80fd<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5\u8f6c\u901f<\/td>\n<td>\u6839\u636e\u7cfb\u7edf\u9700\u6c42\u8c03\u8282\uff0c\u8282\u7ea6\u8017\u7535\u3001\u964d\u4f4e\u566a\u97f3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">\u9009\u578b\u5efa\u8bae<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>24kW<\/strong>\uff1a\u9002\u5408\u5efa\u7b51\u9762\u79ef&nbsp;<strong>80 - 150\u33a1<\/strong>&nbsp;\u7684\u4f4f\u5b85<\/li>\n<li><strong>28kW<\/strong>\uff1a\u9002\u5408\u5efa\u7b51\u9762\u79ef&nbsp;<strong>120 - 200\u33a1<\/strong>&nbsp;\u7684\u4f4f\u5b85<\/li>\n<\/ul>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u9009\u578b\u5efa\u8bae<\/strong>\uff1a3260W \u662f\u535a\u4e16\u54c1\u724c\u4e2d\u6027\u4ef7\u6bd4\u6700\u9ad8\u7684\u51b7\u51dd\u7089\u9009\u62e9\uff0c\u642d\u914d\u5730\u6696\u4f7f\u7528\uff0c\u957f\u671f\u7701\u4e0b\u7684\u71c3\u6c14\u8d39\u53ef\u8986\u76d6\u4e0e\u666e\u901a\u7089\u7684\u5dee\u4ef7\u3002<\/p>\n<\/blockquote>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 class=\"wp-block-heading\">G6Z\u8ffd\u5149\u7248Plus \u2014 \u5e38\u89c4\u58c1\u6302\u7089<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u4ea7\u54c1\u540d\u79f0<\/strong>\uff1aG6\u8ffd\u5149\u7248 \/ G6Z\u8ffd\u5149\u7248Plus<\/li>\n<li><strong>\u54c1\u724c\u53e3\u53f7<\/strong>\uff1aLIVE LIKE A BOSCH \/ \u5c0f\u5de7\u767e\u642d \u7eb5\u4eab\u6e29\u6696<\/li>\n<li><strong>\u4ea7\u54c1\u7c7b\u522b<\/strong>\uff1a\u5e38\u89c4\u58c1\u6302\u7089<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">\u4e3b\u8981\u529f\u80fd\u7279\u70b9<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u5168\u5c4b\u6052\u6e29\u91c7\u6696<\/strong>&nbsp;\u2014 \u63d0\u4f9b\u7a33\u5b9a\u7684\u5ba4\u5185\u4f9b\u6696<\/li>\n<li><strong>24\u5c0f\u65f6\u8212\u9002\u70ed\u6c34<\/strong>&nbsp;\u2014 \u6c90\u6d74\u7528\u6c34\u3001\u53a8\u623f\u7528\u6c34\u4e00\u673a\u6ee1\u8db3<\/li>\n<li><strong>\u7cbe\u51c6\u63a7\u6e29\u8282\u80fd\u9ad8\u6548<\/strong>&nbsp;\u2014 \u652f\u6301\u535a\u4e16MR\u7cfb\u5217\u3001OT\u6e29\u63a7\u5668\u4f7f\u7528\uff0c\u53ef\u5b9e\u73b0\u623f\u95f4\u6e29\u5ea6\u7684\u7cbe\u51c6\u8c03\u63a7\uff0c\u7089\u5b50\u51fa\u6c34\u6e29\u5ea6\u66f4\u7cbe\u786e\uff0c\u8212\u9002\u52a0\u500d\uff0c\u8282\u7701\u80fd\u8017<\/li>\n<li><strong>\u7d27\u51d1\u5c3a\u5bf8\u8bbe\u8ba1<\/strong>&nbsp;\u2014 \u5c0f\u7a7a\u95f4\u5b89\u88c5\u4e5f\u6beb\u65e0\u95ee\u9898<\/li>\n<li><strong>\u9759\u97f3\u8fd0\u884c<\/strong>&nbsp;\u2014 \u63d0\u4f9b\u5b89\u9759\u7f8e\u597d\u7684\u751f\u6d3b\u73af\u5883\uff0c\u8ba9\u6e29\u6696\u6084\u7136\u800c\u81f3<\/li>\n<li><strong>\u80cc\u5149LED\u663e\u793a<\/strong><\/li>\n<li><strong>\u5feb\u901f\u5b89\u88c5<\/strong>&nbsp;\u2014 \u53ea\u9700\u51e0\u4e2a\u7b80\u5355\u7684\u6b65\u9aa4\u5c31\u80fd\u591f\u5feb\u901f\u5b89\u88c5<\/li>\n<li><strong>\u9ad8\u54c1\u8d28\u5fb7\u56fd\u7cbe\u5de5\u96f6\u90e8\u4ef6<\/strong>&nbsp;\u2014 \u4f7f\u7528\u5bff\u547d\u66f4\u957f\u4e45\u3001\u66f4\u5b89\u5fc3<\/li>\n<\/ul>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5c0f\u7a7a\u95f4 \u00b7 \u5927\u4eab\u53d7<\/p>\n<\/blockquote>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"znkzxt\" class=\"wp-block-heading\">\u4e5d\u3001\u667a\u80fd\u63a7\u5236\u7cfb\u7edf<\/h2>\n<h3 class=\"wp-block-heading\">OR\u7cfb\u5217\u58c1\u6302\u7089\u6e29\u63a7\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u5177\u6709 OpenTherm BUS (OT) \u901a\u8baf\u534f\u8bae\u7684\u535a\u4e16\u58c1\u6302\u7089\uff0c\u5982G7100\u3001G6300\u3001G6100\u3001G5100\u7b49\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u5668\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u8981\u529f\u80fd<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>OR60\u58c1\u6302\u7ebf\u63a7\u5236\u5668<\/strong><\/td>\n<td>\u53ef\u76f4\u63a5\u64cd\u63a7\u58c1\u6302\u7089\uff1b\u6807\u51c686mm\u5b89\u88c5\u5c3a\u5bf8\uff1b\u5730\u6696\u548c\u6696\u6c14\u7247\u91c7\u6696\u7cfb\u7edf\u5747\u53ef\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td><strong>OR90\u91c7\u6696\u63a7\u5236\u5668<\/strong><\/td>\n<td>\u53ef\u901a\u8fc7\u611f\u77e5\u5ba4\u5185\u6e29\u5ea6\u63a7\u5236\u58c1\u6302\u7089\u542f\u505c\uff1b\u53ef\u884c\u6a21\u5f0f\u7f16\u7a0b\uff1b\u5730\u6696\u548c\u6696\u6c14\u7247\u7cfb\u7edf\u5747\u53ef\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td><strong>OR30 RF\u65e0\u7ebf\u6e29\u63a7\u5668<\/strong><\/td>\n<td>\u8bbe\u7f6e\u623f\u95f4\u6e29\u5ea6\uff1b\u8bbe\u7f6e\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\uff1b\u6709\u7ebf\u5b89\u88c5\u6216\u8005\u65e0\u7ebf\u5b89\u88c5\uff1b\u6545\u969c\u4ee3\u7801\u663e\u793a\u53ca\u590d\u4f4d\u529f\u80fd<\/td>\n<\/tr>\n<tr>\n<td><strong>OR80 RF\u65e0\u7ebf\u6e29\u63a7\u5668<\/strong><\/td>\n<td>\u8bbe\u7f6e\u623f\u95f4\u6e29\u5ea6\uff1b\u8bbe\u7f6e\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\uff1b\u5f3a\u5927\u7684\u7f16\u7a0b\u529f\u80fd\uff1b\u6709\u7ebf\u5b89\u88c5\u6216\u8005\u65e0\u7ebf\u5b89\u88c5\uff1b\u6545\u969c\u4ee3\u7801\u663e\u793a\u53ca\u590d\u4f4d\u529f\u80fd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u65e0\u7ebf\u63a5\u6536\u5668<\/strong><\/td>\n<td>\u4ec5\u7528\u4e8e\u65e0\u7ebf\u6e29\u63a7\u5668 OR30 RF \/ OR80 RF<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">MR50\u623f\u95f4\u6e29\u63a7\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u4e3b\u8981\u7528\u4e8e\u5bb6\u5ead\u5730\u6696\u7cfb\u7edf\uff0c\u80fd\u591f\u63a7\u5236\u7535\u70ed\u6267\u884c\u5668\uff0c\u63d0\u4f9b\u5206\u533a\u63a7\u6e29\u529f\u80fd\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u8bbe\u7f6e\u5e76\u663e\u793a\u623f\u95f4\u6e29\u5ea6<\/li>\n<li>\u7f16\u8f91\u529f\u80fd<\/li>\n<li>\u9632\u51bb\u4fdd\u62a4\u529f\u80fd<\/li>\n<li>\u5927LCD\u5c4f\uff0c\u4e00\u4f53\u5316\u5f27\u5f62\u8868\u9762\u8bbe\u8ba1\uff0c\u7b80\u6d01\u6d41\u7545<\/li>\n<li>\u9ad8\u8010\u5019\u6027\uff0c\u66f4\u52a0\u5b89\u5168\uff0c\u8010\u5019\u6027\u5f3a<\/li>\n<li>\u5b89\u88c5\u7b80\u5355\uff0c\u64cd\u4f5c\u4fbf\u6377<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">CR10\u58c1\u6302\u7089\u6e29\u63a7\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u5177\u6709 OpenTherm (OT) \u6216 EMS BUS \u901a\u8baf\u534f\u8bae\u7684\u535a\u4e16\u58c1\u6302\u7089\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u6b27\u6d32\u539f\u88c5\u8fdb\u53e3\uff0c\u73b0\u4ee3\u5de5\u4e1a\u8bbe\u8ba1<\/li>\n<li>\u8bbe\u7f6e\u5e76\u663e\u793a\u623f\u95f4\u6e29\u5ea6<\/li>\n<li>\u53ef\u4e0e MZ100 \u63a7\u5236\u6a21\u5757\u7ed3\u5408\u4f7f\u7528\u8fdb\u884c\u533a\u57df\u6e29\u5ea6\u63a7\u5236<\/li>\n<li>\u53ef\u4e0e CW400 \u7ed3\u5408\u4f5c\u4e3a\u8fdc\u7a0b\u6e29\u5ea6\u4f20\u611f\u5668<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">CW400\u6c14\u5019\u8865\u507f\u578b\u7cfb\u7edf\u63a7\u5236\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u5177\u6709 EMS BUS \u901a\u8baf\u534f\u8bae\u7684\u535a\u4e16\u58c1\u6302\u7089\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u7528\u4e8e\u590d\u6742\u91c7\u6696\u7cfb\u7edf\u7684\u7cfb\u7edf\u6e29\u63a7\u5668<\/li>\n<li>\u6c14\u5019\u8865\u507f\u7cfb\u7edf\u63a7\u5236\uff0c\u542b\u5ba4\u5916\u6e29\u5ea6\u4f20\u611f\u5668\uff0c\u65e0\u9700\u8fdc\u7a0b\u63a7\u5236\u5373\u53ef\u63a7\u5236\u6700\u591a4\u4e2a\u91c7\u6696\u56de\u8def<\/li>\n<li>\u53ef\u7528\u4f5c\u623f\u95f4\u6e29\u63a7\u5668\uff0c\u96c6\u6210\u4e86\u623f\u95f4\u6e29\u5ea6\u4f20\u611f\u5668<\/li>\n<li>\u592a\u9633\u80fd\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34<\/li>\n<li>\u6bcf\u4e2a\u91c7\u6696\u56de\u8def\u67092\u4e2a\u65f6\u95f4\u7f16\u7a0b<\/li>\n<li>\u91c7\u6696\u6bcf\u5468\u65f6\u949f\u7f16\u7a0b\uff0c\u6bcf\u59296\u4e2a\u5207\u6362\u70b9<\/li>\n<li>\u6bcf\u4e2a\u751f\u6d3b\u70ed\u6c34\u56de\u8def\u6709\u65f6\u949f\u7a0b\u5e8f<\/li>\n<li>\u89e6\u6478\u6309\u952e<\/li>\n<li>\u9ad8\u5206\u8fa8\u7387\u7684\u6db2\u6676\u663e\u793a\u5c4f\uff0c\u4f18\u8d8a\u7684\u64cd\u4f5c\u4f7f\u7528\u6027<\/li>\n<li>\u6e29\u5ea6\u6d41\u91cf\u8c03\u8282\u63a7\u5236\uff08\u51cf\u5c11\u6cf5\u8fd0\u884c\u65f6\u95f4\u7684\u529f\u7387\u63a7\u5236\uff0c\u4f18\u5316\u6cf5\u8fd0\u884c\u65f6\u95f4\u7684\u6d41\u91cf\u63a7\u5236\uff09<\/li>\n<li>\u81ea\u52a8\u6e05\u6d01\uff0c\u6bcf\u65e5\u53ef\u7f16\u7a0b<\/li>\n<li>\u5185\u7f6e\u5927\u91cf\u670d\u52a1\u5668\u529f\u80fd\uff0c\u4f8b\u5982\u6df7\u5408\u6cf5\u3001\u9600\u95e8\u7b49\u7684\u8bbe\u7f6e\u548c\u529f\u80fd\u6d4b\u8bd5\u7b49<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u533a\u57df\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MZ100<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u53ef\u901a\u8fc7\u63a7\u5236\u6c34\u6cf5\u3001\u9600\u95e8\u3001\u6e29\u5ea6\u4f20\u611f\u5668\u5b9e\u73b0\u533a\u57df\u6e29\u5ea6\u63a7\u5236<\/li>\n<li>\u4e0eCR10\u7ed3\u5408\u4f7f\u7528\uff0c\u6700\u591a\u63a7\u52363\u4e2a\u672a\u6df7\u5408\u7684\u91c7\u6696\u56de\u8def<\/li>\n<li>\u5728\u4e00\u4e2a\u7cfb\u7edf\u4e2d\u6700\u591a\u53ef\u4ee5\u67093\u4e2aMZ100\u63a7\u5236\u5668\u6a21\u5757<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6c34\u8def\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MM100<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u53ef\u63a7\u52361\u4e2a\u4f9b\u70ed\u56de\u8def\u7528\u4e8e\u5728\u6df7\u6c34\u7cfb\u7edf\u6216\u975e\u6df7\u6c34\u7cfb\u7edf\u4e2d\u63a7\u5236\/\u5173\u9600\u95e8<\/li>\n<li>\u4e5f\u53ef\u63a7\u5236\"\u4e8c\u6b21\u56de\u8def\"\u4e4b\u540e\u7684\u6c34\u7bb1\/\u7f13\u51b2\u7f38<\/li>\n<li>1\u4e2a\u91c7\u6696\u56de\u8def\u7684\u6c34\u529b\u5faa\u73af<\/li>\n<li>1\u4e2a\u91c7\u6696\u56de\u8def\u6216\u56de\u8def\u7684\u6df7\u5408\u5668\u6253\u5f00\/\u5173\u9600<\/li>\n<li>\u751f\u6d3b\u70ed\u6c34\u6c34\u529b\u5faa\u73af\u30011\u4e2a\u5faa\u73af\u6c34\u6cf5<\/li>\n<li>\u53bb\u8026\u4f20\u8f93\u5668\u548c\u6d41\u91cf\u6e29\u5ea6\u4f20\u611f\u5668<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u592a\u9633\u80fd\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MS100<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u63a7\u5236\u592a\u9633\u80fd\u96c6\u70ed\u52a0\u70ed\u4ee5\u53ca\u592a\u9633\u80fd\u8f85\u52a9\u91c7\u6696<\/li>\n<li>\u592a\u9633\u80fd\u548c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u8054\u52a8\u7cfb\u7edf\uff0c\u771f\u6b63\u6210\u4e3a\u4f1a\u601d\u8003\u7684\u91c7\u6696\u63a7\u5236\u4e2d\u5fc3<\/li>\n<li>\u5e26\u6765\u667a\u6167\u8282\u80fd\u7684\u7efc\u5408\u4eab\u53d7<\/li>\n<li>\u592a\u9633\u80fd\u751f\u6d3b\u70ed\u6c34\u548c\u592a\u9633\u80fd\u4f18\u5316\u529f\u80fd<\/li>\n<li>\u652f\u6301\u9ad8\u6548\u6cf5<\/li>\n<li>\u5e26\u5206\u79bb\u70ed\u4ea4\u6362\u5668\u62162\u4e2a\u4e32\u8054\u6c34\u7bb1\u7684\u592a\u9633\u80fd\u751f\u6d3b\u70ed\u6c34\u6c34\u7bb1<\/li>\n<li>\u70ed\u6d88\u6bd2<\/li>\n<li>\u53cc\u5339\u914d\u6d41\u91cf<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u7ea7\u8054\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MC400<\/h3>\n<ul class=\"wp-block-list\">\n<li>MC400\u7ea7\u8054\u6a21\u5757\u53ef\u4ee5\u8ba9\u591a\u53f0\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u5e76\u8054\u4f7f\u7528\uff0c\u5bf9\u4e8e\u7cfb\u7edf\u6765\u8bf4\uff0c\u5c31\u5982\u540c\u662f\u5728\u4f7f\u7528\u4e00\u53f0\u5927\u9505\u7089<\/li>\n<li>\u7528\u4e8e\u6700\u591a4\u53f0EMS\u58c1\u6302\u7089\u7ea7\u8054<\/li>\n<li>\u6700\u591a5\u4e2a\u7ea7\u8054\u6a21\u5757\u5728\u7cfb\u7edf\u4e2d\uff0c\u5373\u6700\u591a16\u53f0EMS\u58c1\u6302\u7089<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u667a\u80fd\u91c7\u6696\u63a7\u5236\u5668 MR120i \/ MR100i RF<\/h3>\n<h4 class=\"wp-block-heading\">MR120i \u667a\u80fd\u91c7\u6696\u63a7\u5236\u5668<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5168\u5c4b\u5206\u5ba4\u91c7\u6696\u7684\u667a\u80fd\u5c0f\u7ba1\u5bb6<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5b9e\u65f6\u8c03\u8282\u91c7\u6696\uff0c\u4e0e\u535a\u4e16\u58c1\u6302\u7089\u914d\u5408\u5de5\u4f5c\uff0c\u5b9e\u73b0\u7cbe\u51c6\u63a7\u6e29<\/li>\n<li><strong>\u4e91\u7aef\u6c14\u5019\u8865\u507f\u529f\u80fd<\/strong>\uff1a\u65e0\u60e7\u5929\u6c14\u7a81\u53d8\uff0c\u5e26\u6765\u8212\u9002\u7684\u6052\u6e29\u4f53\u9a8c<\/li>\n<li><strong>FOTA\u8fdc\u7a0b\u5347\u7ea7<\/strong>\uff1a\u652f\u6301\u4e00\u952e\u65e0\u611f\u8fdc\u7a0b\u5347\u7ea7<\/li>\n<li><strong>\u63a5\u5165\u300c\u6676\u5fa1\u667a\u80fd\u300d\u5fae\u4fe1\u5c0f\u7a0b\u5e8f<\/strong>\uff1a\u53ef\u81ea\u5b9a\u4e49\u591a\u573a\u666f\u6a21\u5f0f\uff0c\u53ef\u8fdc\u7a0b\u8bfb\u53d6\u58c1\u6302\u7089\u6545\u969c\u4ee3\u7801<\/li>\n<li><strong>\u4e3b\u63a7\u5168\u7cfb\u6807\u914dWi-Fi<\/strong>\uff1a\u968f\u65f6\u67e5\u770b\u8bbe\u5907\u72b6\u6001<\/li>\n<li><strong>\u5168\u5c4b\u5206\u5ba4\u63a7\u6e29<\/strong>\uff1a\u652f\u6301\u4e3b\u5367\u3001\u6b21\u5367\u3001\u5ba2\u5385\u3001\u4e66\u623f\u3001\u6d74\u5ba4\u72ec\u7acb\u6e29\u5ea6\u8bbe\u5b9a<\/li>\n<li><strong>\u5185\u7f6e\u673a\u5668\u5b66\u4e60AI\u7b97\u6cd5<\/strong>\uff1a\u7ed9\u6bcf\u4f4d\u7528\u6237\u63d0\u4f9b\u72ec\u7279\u7684\u8212\u9002\u4f53\u9a8c<\/li>\n<li><strong>\u535a\u4e164.0\u5de5\u4e1a\u7f8e\u5b66\u8bbe\u8ba1<\/strong>\uff1a\u5916\u89c2\u7b80\u7ea6\u5927\u65b9\uff0c\u5b89\u88c5\u65b9\u4fbf<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">\u6838\u5fc3\u6280\u672f<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u81ea\u7814\u300c\u6052\u6e29\u63a7\u7130\u300d\u7b97\u6cd5<\/strong>\uff1a\u82af\u7247\u642d\u8f7d\u535a\u4e16\u81ea\u7814\u7b97\u6cd5\uff0c\u7eff\u8272\u7cbe\u7b97\uff0c\u9ad8\u6548\u8282\u80fd<\/li>\n<li><strong>\u63a7\u7089\u63a7\u6e29\u53cc\u64ce\u53cc\u6548<\/strong>\uff1a\u964d\u4f4e50%\u4ee5\u4e0a\u58c1\u6302\u7089\u542f\u505c\u6b21\u6570\uff0c\u51cf\u5c11\u70b9\u706b\u71c3\u6c14\u6d88\u8017\uff0c\u5927\u5e45\u5ef6\u957f\u58c1\u6302\u7089\u4f7f\u7528\u5bff\u547d<\/li>\n<li><strong>\u5168\u5c4b\u8054\u63a7<\/strong>\uff1a\u83b7\u53d6\u7cbe\u786e\u6e29\u5ea6\u9700\u6c42\u4fe1\u606f\uff0c\u52a9\u529b\u58c1\u6302\u7089\u7cbe\u51c6\u8f93\u51fa<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">MR100i RF \u65e0\u7ebf\u7248\u91c7\u6696\u63a7\u5236\u5668<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u771f\u65e0\u7ebf<\/td>\n<td>\u65e0\u7ebf\u8fde\u63a5\uff0c\u65e0\u9700\u5e03\u7ebf<\/td>\n<\/tr>\n<tr>\n<td>\u968f\u5fc3\u6446\u653e<\/td>\n<td>\u6446\u653e\u4f4d\u7f6e\u4e0d\u53d7\u9650\u5236<\/td>\n<\/tr>\n<tr>\n<td>\u968f\u5fc3\u63a7<\/td>\n<td>\u81ea\u7531\u638c\u63a7\u6e29\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u957f\u7eed\u822a<\/td>\n<td>\u5f85\u673a\u65f6\u957f\u8d85\u8fc76\u4e2a\u6708<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"rsxt1\" class=\"wp-block-heading\">\u5341\u3001\u70ed\u6c34\u7cfb\u7edf\uff08\u6c34\u7bb1\uff09<\/h2>\n<h3 class=\"wp-block-heading\">\u7cd6\u74f7\u6c34\u7bb1<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u6b27\u6d32\u8bbe\u8ba1\u7406\u5ff5 \u8212\u9002\u70ed\u6c34\u4eab\u53d7<\/strong>\uff1a\u6e90\u81ea\u6b27\u6d32\u7684\u6c34\u7bb1\u7ed3\u6784\u8bbe\u8ba1\u7406\u5ff5\uff0c\u4e25\u683c\u9075\u5b88\u5fb7\u56fd\u5de5\u4e1a\u6807\u51c6DIN4753\u7684\u54c1\u8d28\u8981\u6c42\uff0c\u627f\u538b\u80fd\u529b\u5f3a\uff0c\u9002\u7528\u4e8e\u6c34\u8d28\u7684\u9ad8\u8d28\u91cf\u7cd6\u74f7\u6c34\u7bb1\uff0c\u4fdd\u8bc1\u9ad8\u8212\u9002\u5ea6\u7684\u70ed\u6c34\u9700\u6c42<\/li>\n<li><strong>\u5fb7\u56fd\u7cbe\u5de5\u5236\u9020 \u94f8\u5c31\u7a33\u5b9a\u53ef\u9760<\/strong>\uff1a\u5fb7\u56fd\u5de5\u827a\u6807\u51c6\uff0c\u7cbe\u5de5\u5236\u9020\u5320\u5fc3\u53ef\u9760\uff1b\u8d85\u8fc7860\u2103\u9ad8\u6e29\u70e7\u7ed3\u91d1\u5c5e\u5185\u80c6\u8868\u9762\u73bb\u7483\u5316\uff1b\u751f\u6210\u91d1\u5c5e\u5c42\u4e0e\u7cd6\u74f7\u7684\u7ed3\u5408\u4f53\uff0c\u675c\u7edd\u6f0f\u6c14\u3001\u6c7d\u6ce1\u3001\u7126\u70b9\u7b49\u7f3a\u9677\uff1b\u5185\u80c6\u3001\u76d8\u7ba1\u548c\u4e0b\u5c01\u5934\u90fd\u642a\u5851\u540e\u6574\u4f53\u55b7\u5851\uff0c\u6240\u6709\u9600\u5747\u88ab\u642a\u74f7\u8986\u76d6\uff1b\u4e0a\u4e0b\u5c01\u5934\u91c7\u7528\u53cc\u53e3\u5f0f\u7ed3\u6784\uff0c\u73af\u7f1d\u642a\u74f7<\/li>\n<li><strong>\u6709\u6548\u6291\u83cc\u9632\u8150 \u5b88\u62a4\u5bb6\u4eba\u5065\u5eb7<\/strong>\uff1a33mm\u5927\u76f4\u5f84\u65e0\u94c5\u9541\u68d2(\u727a\u7272\u6781\u4fdd\u62a4)\u5bf9\u642a\u74f7\u5185\u80c6\u8fdb\u884c\u4fdd\u62a4\uff0c\u786e\u4fdd\u6c34\u7bb1\u957f\u671f\u4f7f\u7528\u4e0d\u88ab\u8150\u8680\uff1b\u642a\u74f7\u91c9\u5c42\uff0c\u6709\u6548\u6291\u83cc<\/li>\n<li><strong>\u9ad8\u6548\u4fdd\u6e29\u79d1\u6280 \u517c\u987e\u8282\u80fd\u8212\u9002<\/strong>\uff1a\u53d1\u6ce1\u5c42\u4fdd\u6e29\u91c7\u7528\u5c01\u95ed\u5f0f\u9ad8\u538b\u53d1\u6ce1\uff0c\u73af\u4fdd\u65e0\u6c1f\u805a\u6c28\u916f\u53d1\u6ce1\uff1b\u5bc6\u5ea6\u9ad8\u8fbe40g\/cm\u00b3\uff0c\u70ed\u635f\u5931\u4f4e\u4e8e\u56fd\u6807\u8981\u6c4237%<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6b27\u5f0f\u8212\u9002\u7cfb\u5217<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6c34\u7bb1\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST150-150EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST200-200EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST300-300EC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5185\u8154\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u9053\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u539a\u5ea6<\/td>\n<td>mm<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u9ad8\u5ea6<\/td>\n<td>mm<\/td>\n<td>985<\/td>\n<td>1248<\/td>\n<td>1713<\/td>\n<\/tr>\n<tr>\n<td><strong>\u50a8\u7f50\u91cf(\u603b\u8ba1)<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u50a8\u91cf<\/td>\n<td>L<\/td>\n<td>150<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u635f\u8017\u6027\u80fd<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u635f\u8017<\/td>\n<td>W\/\u33a1K<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u9ad8\u6e29\u5ea6<\/td>\n<td>\u2103<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u70ed\u635f\u8017\u6570\u503c\u7b26\u5408 GB\/T 28745 \u6807\u51c6<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">\u7ecf\u5178\u65f6\u5c1a\u7cfb\u5217<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u91d1\u5c5e\u5916\u58f3\uff0c\u8010\u8150\u8680\uff0c\u6297\u7d2b\u5916\u7ebf\uff0c\u53ef\u878d\u5408\u591a\u79cd\u5bb6\u5ead\u88c5\u4fee\u98ce\u683c<\/li>\n<li>\u5236\u5f0f\u591a\u6837\uff0c\u53ef\u4e0e\u592a\u9633\u80fd\u3001\u9505\u7089\u3001\u70ed\u6cf5\u8fdb\u884c\u591a\u80fd\u6e90\u7cfb\u7edf\u7ec4\u5408<\/li>\n<li>120-200L \u4e0a\u51fa\u6c34\u5355\u76d8\u7ba1<\/li>\n<li>150-300L \u4fa7\u51fa\u6c34\u5355\u76d8\u7ba1<\/li>\n<li>200-300L \u4fa7\u51fa\u6c34\u53cc\u76d8\u7ba1<\/li>\n<li>400\/500L \u51fa\u6c34\u7ba1\/\u53cc\u76d8\u7ba1<\/li>\n<\/ul>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6c34\u7bb1\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST150-500EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST200-500EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST300-400EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST400-600EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST500-500EC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5185\u8154\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>650<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u9053\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>750<\/td>\n<td>580<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u539a\u5ea6<\/td>\n<td>mm<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>70<\/td>\n<td>50<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u9ad8\u5ea6<\/td>\n<td>mm<\/td>\n<td>985<\/td>\n<td>1248<\/td>\n<td>1713<\/td>\n<td>1665<\/td>\n<td>1248<\/td>\n<\/tr>\n<tr>\n<td><strong>\u50a8\u7f50\u91cf<\/strong><\/td>\n<td>L<\/td>\n<td>150<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<td>400<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"gsxxylxfs\" class=\"wp-block-heading\">\u5341\u4e00\u3001\u516c\u53f8\u4fe1\u606f\u4e0e\u8054\u7cfb\u65b9\u5f0f<\/h2>\n<h3 class=\"wp-block-heading\">\u516c\u53f8\u8054\u7cfb\u65b9\u5f0f<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u535a\u4e16\u70ed\u529b\u6280\u672f\uff08\u5317\u4eac\uff09\u6709\u9650\u516c\u53f8<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u5730\u5740\uff1a\u5317\u4eac\u7ecf\u6d4e\u6280\u672f\u5f00\u53d1\u533a\u6c38\u660c\u5357\u8def6\u53f71\u53f7\u697c3\u5c42<\/li>\n<li>\u90ae\u7f16\uff1a100176<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u535a\u4e16\u70ed\u529b\u6280\u672f\uff08\u4e0a\u6d77\uff09\u6709\u9650\u516c\u53f8<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u5730\u5740\uff1a\u4e0a\u6d77\u5e02\u5609\u5b9a\u533a\u9a6c\u9646\u9547\u4e30\u767b\u8def388\u53f7<\/li>\n<li>\u90ae\u7f16\uff1a201801<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u5168\u56fd\u552e\u540e\u670d\u52a1\u70ed\u7ebf\uff1a400 820 6017<\/strong><\/li>\n<li>\u5728\u7ebf\u54a8\u8be2\uff1a<a href=\"https:\/\/www.bosch-climate.cn\/contact\/consult\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.bosch-climate.cn\/contact\/consult<\/a><\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u53d1\u5c55\u65f6\u95f4\u7ebf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u4efd<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u91cc\u7a0b\u7891\u4e8b\u4ef6<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1731<\/td>\n<td>\u4e1c\u65af\u5fb7\u5c14\u521b\u7acb<\/td>\n<\/tr>\n<tr>\n<td>1894<\/td>\n<td>\u53d1\u660e\u4f4e\u538b\u7535\u78c1\u5f0f\u5438\u5c18\u5e76\u83b7\u53d6\u4e13\u5229<\/td>\n<\/tr>\n<tr>\n<td>1896<\/td>\n<td>\u7f57\u4f2f\u7279\u00b7\u535a\u4e16\u521b\u7acb\uff0c\u63a8\u51fa\u9996\u6b3e\u71c3\u6c14\u70ed\u6c34\u5668\u8bbe\u5907<\/td>\n<\/tr>\n<tr>\n<td>1962<\/td>\n<td>\u535a\u4e16\u9996\u53f0Combi boiler\u9762\u5e02<\/td>\n<\/tr>\n<tr>\n<td>1970<\/td>\n<td>\u5f00\u59cb\u5236\u9020\u5730\u6696<\/td>\n<\/tr>\n<tr>\n<td>1972<\/td>\n<td>\u535a\u4e16\u9996\u6b21\u63a8\u51fa\u70ed\u5f0f\u7a7a\u8c03\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>1976<\/td>\n<td>\"Tritherm house\"\u5728\u5fb7\u56fd\u53d6\u5f97\u5236\u9020\u4f7f\u7528\u5927\u578b\u592a\u9633\u80fd\u70ed\u80fd\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>1986<\/td>\n<td>\u535a\u4e16\u9996\u6b21\u51fa\u53e3\u4e2d\u56fd<\/td>\n<\/tr>\n<tr>\n<td>1997<\/td>\n<td>\u9996\u4e2a\u9879\u76ee\u8fdb\u5165\u4e2d\u56fd<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>\u535a\u4e16\u70ed\u529b\u6280\u672f\u6b63\u5f0f\u8fdb\u5165\u4e2d\u56fd\u5e02\u573a<\/td>\n<\/tr>\n<tr>\n<td>2005<\/td>\n<td>\u5f00\u59cb\u5728\u4e2d\u56fd\u5efa\u7acb\u6280\u672f\u5de5\u5382<\/td>\n<\/tr>\n<tr>\n<td>2011<\/td>\n<td>\u535a\u4e16\u9996\u4e2a\u80fd\u6e90\u81ea\u5efa\u5730\u6696\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>2015<\/td>\n<td>\u535a\u4e16\u9996\u5bb6\u5b8c\u5168\u5b89\u5168ENWA\u8ba4\u8bc1\u7684\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u53ca\u70ed\u6c34\u50a8\u4ea7\u54c1<\/td>\n<\/tr>\n<tr>\n<td>2020<\/td>\n<td>\u6b27\u6d32\u4e4b\u661f10\u5468\u5e74\u8363\u8000\u4e0a\u5e02<\/td>\n<\/tr>\n<tr>\n<td>2021<\/td>\n<td>\u535a\u4e16\u65b0\u4e00\u4ee3\u65d7\u8230\u4ea7\u54c1G7100W\u9686\u91cd\u4e0a\u5e02<\/td>\n<\/tr>\n<tr>\n<td>2023<\/td>\n<td>\u535a\u4e16G8550i W\u5168\u6c14\u5019\uff1b\u535a\u4e16\u65b0G6300AW\/W\u7cfb\u5217\u6b63\u5f0f\u4e0a\u5e02<\/td>\n<\/tr>\n<tr>\n<td>2024<\/td>\n<td>\u535a\u4e16\u65b0\u88c5\u8fdb\u53e3\uff1b\u535a\u4e16G8550i W\u5168\u6c14\u5019\uff1b\u535a\u4e16\u65b0G6300AW\/W\u7cfb\u5217\u6b63\u5f0f\u4e0a\u5e02<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 class=\"wp-block-heading\">\u9644\u5f55\uff1a\u4ea7\u54c1\u578b\u53f7\u901f\u67e5\u8868<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u54c1\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u529f\u7387<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7c7b\u578b<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Condens 9000i WM<\/td>\n<td>GC 9000i WM<\/td>\n<td>36kW<\/td>\n<td>\u51b7\u51dd\u96c6\u6210\u7089<\/td>\n<td>\u4e00\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>Condens 8700i W<\/td>\n<td>GC 8700i WM<\/td>\n<td>24\/35kW<\/td>\n<td>\u51b7\u51dd\u4e24\u7528\u7089<\/td>\n<td>\u4e00\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>Condens 7100 W<\/td>\n<td>OC 7100W<\/td>\n<td>24-39kW<\/td>\n<td>\u51b7\u51dd\u4e24\u7528\u7089<\/td>\n<td>\u4e00\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>\u6b27\u6d32\u8d35\u65cf<\/td>\n<td>DNZ\u7cfb\u5217<\/td>\n<td>25\/35kW<\/td>\n<td>\u51b7\u51dd\u4e24\u7528\u7089<\/td>\n<td>\u4e00\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>G8550i W<\/td>\n<td>G8550i W<\/td>\n<td>24kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248<\/td>\n<td>ZWC\u7cfb\u5217<\/td>\n<td>24\/28\/35kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>G7\u955c\u9762\u7248<\/td>\n<td>G7200W<\/td>\n<td>24\/28kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>G7350i W (G7 Pro)<\/td>\n<td>L1P27-G7350iW<\/td>\n<td>24kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>C3260W<\/td>\n<td>GC3260W<\/td>\n<td>24\/28kW<\/td>\n<td>\u51b7\u51dd\u4e24\u7528\u7089<\/td>\n<td>\u4e00\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>G6Z\u8ffd\u5149\u7248plus<\/td>\n<td>G6Z Plus<\/td>\n<td>-<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>G6300W<\/td>\n<td>G6300W<\/td>\n<td>18\/22kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<tr>\n<td>G6100W<\/td>\n<td>L1P31-G6100W<\/td>\n<td>28kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\u7089<\/td>\n<td>\u4e8c\u7ea7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8d44\u6599\u6765\u6e90<\/strong>\uff1a\u535a\u4e16\u5b98\u65b9\u6837\u518c\u4e0e\u4ea7\u54c1\u8d44\u6599\uff082024 \u5e74 9 \u6708\u7248\uff09\uff1b\u53c2\u6570\u914d\u7f6e\u4ee5\u8bbe\u5907\u94ed\u724c\u4e0e\u539f\u5382\u6700\u65b0\u8d44\u6599\u4e3a\u51c6\u3002<\/p>\n<\/blockquote>\n<\/blockquote>\n<h2 class=\"wp-block-heading\">\u9644\uff1a\u535a\u4e16\u58c1\u6302\u7089\u7efc\u5408\u6837\u518c \u5b8c\u6574\u89e3\u6790\u62a5\u544a\uff082024\u5e74\u5b8c\u6574\u7248\uff09<\/h2>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6765\u6e90<\/strong>\uff1aFLBOOK\u7535\u5b50\u753b\u518c<br \/><strong>\u4e66\u520a\u540d\u79f0<\/strong>\uff1a01-\u535a\u4e16\u58c1\u6302\u7089\u7efc\u5408\u6837\u518c<br \/><strong>\u53d1\u5e03\u65f6\u95f4<\/strong>\uff1a2024-09-09<br \/><strong>\u603b\u9875\u6570<\/strong>\uff1a52\u9875<br \/><strong>\u5206\u7c7b<\/strong>\uff1a\u5546\u4e1a\u753b\u518c\/\u5ba3\u4f20\u518c &gt; \u5bb6\u7535\/\u7535\u5668<\/p>\n<\/blockquote>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n<ol start=\"1\" class=\"wp-block-list\">\n<li>\u54c1\u724c\u4e0e\u516c\u53f8\u4ecb\u7ecd<\/li>\n<li>\u51b7\u51dd\u6280\u672f\u6838\u5fc3<\/li>\n<li>\u4ea7\u54c1\u7cfb\u5217\u8be6\u89e3<\/li>\n<li>\u63a7\u5236\u7cfb\u7edf<\/li>\n<li>\u70ed\u6c34\u7cfb\u7edf\uff08\u6c34\u7bb1\uff09<\/li>\n<li>\u516c\u53f8\u4fe1\u606f\u4e0e\u65f6\u95f4\u7ebf<\/li>\n<\/ol>\n<\/div>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"ppygsjs\" class=\"wp-block-heading\">\u4e00\u3001\u54c1\u724c\u4e0e\u516c\u53f8\u4ecb\u7ecd<\/h2>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u96c6\u56e2<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u5168\u7403\u9886\u5148\u7684\u6280\u672f\u53ca\u670d\u52a1\u4f9b\u5e94\u5546<\/li>\n<li>\u622a\u81f32023\u5e7412\u670831\u65e5\uff0c\u7ea6<strong>427,600\u540d<\/strong>\u5458\u5de5<\/li>\n<li>2023\u8d22\u5e74\u9500\u552e\u989d\u8fbe<strong>916\u4ebf\u6b27\u5143<\/strong><\/li>\n<li>\u4e1a\u52a1\u6db5\u76d64\u4e2a\u4e1a\u52a1\u9886\u57df\uff1a\u79fb\u52a8\u51fa\u884c\u3001\u5de5\u4e1a\u6280\u672f\u3001\u6d88\u8d39\u54c1\u3001\u80fd\u6e90\u4e0e\u5efa\u7b51\u6280\u672f<\/li>\n<li>\u96c6\u56e2\u5305\u62ec<strong>\u7f57\u4f2f\u7279\u00b7\u535a\u4e16\u6709\u9650\u516c\u53f8<\/strong>\u53ca\u5176\u904d\u5e03\u5168\u740360\u4e2a\u56fd\u5bb6\u7684\u7ea6470\u5bb6\u5206\u516c\u53f8\u548c\u533a\u57df\u6027\u516c\u53f8<\/li>\n<li>\u7f57\u4f2f\u7279\u00b7\u535a\u4e16\u57fa\u91d1\u6301\u80a1<strong>94%<\/strong><\/li>\n<li>\u5e03\u5c40\u5168128\u4e2a\u56fd\u5bb6\u548c\u5730\u533a\uff0c\u62e5\u670944,000\u540d\u8f6f\u4ef6\u5de5\u7a0b\u5e08<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u8212\u9002\u79d1\u6280\u4e8b\u4e1a\u90e8<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u6b27\u6d32\u9886\u5148\u7684\u667a\u80fd\u3001\u53ef\u6301\u7eed\u3001\u8282\u80fd\u4f9b\u6696\u3001\u5236\u51b7\u3001\u8212\u9002\u5bb6\u5c45\u53ca\u8fc7\u7a0b\u52a0\u70ed\u89e3\u51b3\u65b9\u6848\u63d0\u4f9b\u5546<\/li>\n<li>2023\u5e74\u9500\u552e\u989d\u7ea6<strong>50\u4ebf\u6b27\u5143<\/strong>\uff0c\u5458\u5de5\u7ea6<strong>14,800\u4eba<\/strong><\/li>\n<li>\u65d7\u4e0b\u62e5\u6709\u591a\u4e2a\u5f3a\u5927\u7684\u56fd\u9645\u548c\u5730\u533a\u54c1\u724c\uff0c20\u4e2a\u751f\u4ea7\u57fa\u5730\u904d\u5e03\u5168\u7403<\/li>\n<li>\u4ea7\u54c1\u7cfb\u5217\u5305\u62ec\uff1a<strong>C9000\u3001C8700<\/strong><\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u5168\u7403\u5de5\u5382\u5e03\u5c40<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u5382<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u56fd\u5bb6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Aveiro<\/td>\n<td>\u8461\u8404\u7259\u00b7\u963f\u5a01\u7f57<\/td>\n<td>\u4f4d\u4e8e\u8461\u8404\u7259\u897f\u5317\u90e8\u6ce2\u5c14\u56fe\u4ee5\u535770\u516c\u91cc\uff0c1977\u5e74\u5efa\uff0c1996\u5e74\u5f00\u59cb\u751f\u4ea7\u58c1\u6302\u7089\uff0c\u5458\u5de51,000\u540d<\/td>\n<\/tr>\n<tr>\n<td>Saint Th\u00e9gonnec<\/td>\n<td>\u6cd5\u56fd\u00b7\u5723\u6cf0\u6208\u5185\u514b<\/td>\n<td>\u751f\u4ea7\u4ece\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u3001\u5bb6\u7528\u70ed\u6c34\u5668\u3001\u5546\/\u5bb6\u7528\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u3001\u5de5\u4e1a\u9505\u7089\u7cfb\u7edf\u5230\u70ed\u6cf5\u4f9b\u7535\u7cfb\u7edf\u7b49\uff0c\u51e0\u4e4e\u8986\u76d6\u5168\u7ebf\u6696\u901a\u4ea7\u54c1<\/td>\n<\/tr>\n<tr>\n<td>Worcester<\/td>\n<td>\u82f1\u56fd\u00b7\u4f0d\u65af\u7279<\/td>\n<td>\u6210\u7acb\u4e8e1962\u5e74\uff0c1996\u5e74\u6210\u4e3a\u5168\u7403\u535a\u4e16\u96c6\u56e2\u7684\u4e00\u90e8\u5206<\/td>\n<\/tr>\n<tr>\n<td>Drancy<\/td>\n<td>\u6cd5\u56fd\u00b7\u5fb7\u6717\u897f<\/td>\n<td>\u6210\u7acb\u4e8e2001\u5e74\uff0c\u5de5\u5382\u91c7\u7528\u5de5\u4e1a4.0\u5236\u9020\u7406\u5ff5<\/td>\n<\/tr>\n<tr>\n<td>Deventer<\/td>\n<td>\u8377\u5170\u00b7\u4ee3\u82ac\u7279\u5c14<\/td>\n<td>\u5de5\u5382\u96c6\u7814\u53d1\u3001\u751f\u4ea7\u3001\u9500\u552e\u53ca\u7269\u6d41\u4e8e\u4e00\u4f53<\/td>\n<\/tr>\n<tr>\n<td>Manisa<\/td>\n<td>\u571f\u8033\u5176\u00b7\u9a6c\u5c3c\u8428<\/td>\n<td>\u627f\u535a\u4e16\u5236\u9020\u4f53\u7cfb\u53ca\u5de5\u4e1a4.0\u7406\u5ff5\uff0c\u751f\u4ea7\u8fc7\u7a0b\u91c7\u7528\u81ea\u52a8\u5316\u3001\u6570\u5b57\u5316\u548c\u5927\u6570\u636e\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td>Shanghai<\/td>\n<td>\u4e2d\u56fd\u00b7\u4e0a\u6d77<\/td>\n<td>\u535a\u4e16\u70ed\u529b\u6280\u672f\u5728\u534e\u91cd\u70b9\u9879\u76ee\u4e4b\u4e00\uff0c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u3001\u71c3\u6c14\u70ed\u6c34\u5668\u53ca\u592a\u9633\u80fd\u5e73\u677f\u96c6\u70ed\u5668\u751f\u4ea7\u57fa\u5730<\/td>\n<\/tr>\n<tr>\n<td>Wernau<\/td>\n<td>\u5fb7\u56fd\u00b7\u97e6\u5c14\u7459<\/td>\n<td>\u8d1f\u8d23\u91c7\u6696\u7cfb\u7edf\u7684\u7814\u53d1\u3001\u751f\u4ea7\u548c\u9500\u552e\uff0c\u5458\u5de51,400\u4f59\u4eba<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"lnjshx\" class=\"wp-block-heading\">\u4e8c\u3001\u51b7\u51dd\u6280\u672f\u6838\u5fc3<\/h2>\n<h3 class=\"wp-block-heading\">\u4ec0\u4e48\u662f\u51b7\u51dd\u7089<\/h3>\n<p class=\"wp-block-paragraph\">\u51b7\u51dd\u5f0f\u58c1\u6302\u7089\u91c7\u7528<strong>\u51b7\u51dd\u6280\u672f<\/strong>\uff0c\u5c06\u70df\u6c14\u4e2d\u7684\u4f59\u70ed\u518d\u6b21\u56de\u6536\u5229\u7528\u3002<\/p>\n<h3 class=\"wp-block-heading\">\u4f20\u7edf\u9505\u7089 vs \u51b7\u51dd\u7089 \u5bf9\u6bd4<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4f20\u7edf\u975e\u51b7\u51dd\u6280\u672f<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u535a\u4e16\u51b7\u51dd\u6280\u672f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u80fd\u6548<\/td>\n<td>\u6309\u4f4e\u4f4d\u70ed\u503c<\/td>\n<td>\u6309\u4f4e\u4f4d\u70ed\u503c<\/td>\n<\/tr>\n<tr>\n<td>\u91cf<\/td>\n<td>\u6c34\u84b8\u6c14\u5e26\u8d70\u7684\u70ed\u91cf\u635f\u5931\u5927<\/td>\n<td>\u6c34\u84b8\u6c14\u5e26\u8d70\u7684\u70ed\u91cf\u635f\u5931\u5c0f<\/td>\n<\/tr>\n<tr>\n<td>\u5206<\/td>\n<td>\u70df\u6c14\u7684\u663e\u70ed\u635f\u5931\u5927<\/td>\n<td>\u70df\u6c14\u7684\u663e\u70ed\u635f\u5931\u5c0f<\/td>\n<\/tr>\n<tr>\n<td>\u914d<\/td>\n<td>\u8f90\u5c04\u635f\u5931\u5927<\/td>\n<td>\u8f90\u5c04\u635f\u5931\u5c0f<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4f9b\u6696\u70ed\u6548\u7387<\/strong><\/td>\n<td><strong>93%<\/strong>*<\/td>\n<td><strong>108%<\/strong>*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">*\u6ce8\uff1a\u4ec5\u9488\u5bf9\u535a\u4e16\u58c1\u6302\u7089\u4ea7\u54c1<br \/>**\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a\uff1a\u68c0\u6d4b\u4ea7\u54c1\u578b\u53f7 L1P27-G6100W 24 CG\uff0c30%\u989d\u5b9a\u70ed\u8d1f\u8377\u6761\u4ef6\u4e0b\uff1bL1GBQ24-GC7100W 25 C\uff0c30%\u989d\u5b9a\u70ed\u8d1f\u8377\u6761\u4ef6<\/p>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u51b7\u51dd\u6838\u5fc3\u6280\u672f<\/h3>\n<h4 class=\"wp-block-heading\">1\ufe0f\u20e3 \u5168\u9884\u6df7\u5f0f\u71c3\u70e7\u7ba1\u7406\u7cfb\u7edf<\/h4>\n<p class=\"wp-block-paragraph\">\u4f7f\u71c3\u6c14\u548c\u7a7a\u6c14\u6309\u8f83\u4f18\u6bd4\u4f8b\u9884\u6df7\uff0c\u4ece\u800c\u71c3\u70e7\u8fbe\u5230\u66f4\u4f73\u72b6\u6001\uff0c\u71c3\u70e7\u6548\u7387\u63d0\u9ad8\u3002\u4f4e\u6e29\u56de\u6c34\u5438\u6536\u9ad8\u6e29\u70df\u6c14\u70ed\u91cf\uff0c\u4ea7\u751f\u51b7\u51dd\u6548\u679c\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u6838\u5fc3\u7ec4\u4ef6\uff1a\u53d8\u9891\u98ce\u673a \u2192 \u9884\u6df7\u8154 \u2192 WB5\u6362\u70ed\u5668 \u2192 \u71c3\u6c14\u6bd4\u4f8b\u9600<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">2\ufe0f\u20e3 \u535a\u4e16WB5\u7ffc\u7fc5\u6c34\u51b7\u6362\u70ed\u5668<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u91d1\u5c5e\u7ea4\u7ef4\u71c3\u70e7\u5668<\/strong>\uff1a\u71c3\u70e7\u6548\u7387\u9ad8\uff0c\u6c61\u67d3\u7269\u6392\u653e\u4f4e\uff0c\u706b\u7130\u7a33\u5b9a\u5b89\u5168\uff0c\u51b7\u51dd\u6c34\u7684\u6392\u653e\u66f4\u5bb9\u6613\u65b9\u4fbf<\/li>\n<li><strong>3D\u6362\u70ed\u7fc5\u7247<\/strong>\uff1a\u8d85\u5927\u6362\u70ed\u9762\u79ef\uff0c\u6bcf\u4e2a\u5c0f\u7fc5\u7247\u7684\u8868\u9762\u79ef\u90fd\u662f\u6362\u70ed\u9762\u79ef\u7684\u5ef6\u4f38<\/li>\n<li><strong>\u5927\u6c34\u9053\uff0c\u5bbd\u58c1\u539a<\/strong>\uff1a\u5927\u6c34\u9053\uff0c\u4e0d\u6613\u5835\u585e\u7ed3\u57a2\uff0c\u5bbd\u58c1\u539a\uff0c\u589e\u52a0\u5f3a\u5ea6\uff0c\u963b\u9694\u566a\u58f0<\/li>\n<li><strong>\u4f7f\u7528\u7845\u94dd\u5408\u91d1\u6750\u8d28<\/strong>\uff1a\u6362\u70ed\u6548\u7387\u9ad8\uff0c\u8010\u8150\u8680\u6027\u5f3a\u3002\u91c7\u7528\u94f8\u9020\u5de5\u827a\uff0c\u65e0\u710a\u7f1d\uff0c\u81f4\u5bc6\u6027\u597d<\/li>\n<li><strong>\u5168\u6c34\u51b7\u7ed3\u6784<\/strong>\uff1a\u5b8c\u5168\u4f9d\u9760\u6c34\u5438\u6536\u70ed\u91cf\uff0c\u65e0\u8010\u706b\u70ed<\/li>\n<\/ul>\n<h4 class=\"wp-block-heading\">3\ufe0f\u20e3 \u516b\u5927\u6838\u5fc3\u6280\u672f<\/h4>\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>\u5e02\u573a\u9500\u91cf\u767e\u4e07\u7ea7\u7845\u94f8\u94dd\u4e3b\u6362\u70ed\u5668\u00b9<\/strong>&nbsp;\u2014 \u65e0\u710a\u7f1d\u6f0f\u6c34\u98ce\u9669\uff0c\u7845\u94dd\u5408\u91d1\u4e00\u4f53\u94f8\u9020\u9020\u578b\uff0c\u65e0\u710a\u70b9<\/li>\n<li><strong>\u9876\u7f6e\u5f0f\u8868\u9762\u71c3\u70e7\u5668<\/strong>&nbsp;\u2014 \u9876\u7f6e\u5f0f\u8bbe\u8ba1\uff0c\u51b7\u6c34\u4e0d\u63a5\u89e6\u71c3\u70e7\u5668\uff0c\u5ef6\u957f\u4f7f\u7528\u5bff\u547d<\/li>\n<li><strong>\u535a\u4e16\u5168\u9884\u6df7\u71c3\u70e7\u6280\u672f<\/strong>&nbsp;\u2014 \u7a7a\u6c14\u4e0e\u71c3\u6c14\u6309\u9002\u91cf\u914d\u6bd4\u71c3\u70e7\uff0c\u4fdd\u8bc1\u6548\u7387\uff0c\u51cf\u5c11\u6709\u5bb3\u7269\u8d28\u6392\u653e<\/li>\n<li><strong>\u667a\u80fd\u6df7\u5408\uff0c\u4f4e\u566a\u9ad8\u6548<\/strong>&nbsp;\u2014 \u6309\u7167\u5b9e\u9645\u7cfb\u7edf\u9700\u6c42\u8c03\u8282\u98ce\u673a\u8f6c\u901f\uff0c\u8282\u7ea6\u80fd\u8017\uff0c\u4fdd\u8bc1\u6548\u7387\uff0c\u964d\u4f4e\u566a\u97f3<\/li>\n<li><strong>\u53d8\u9891\u6cf5\uff08ErP\u6cf5\uff09<\/strong>&nbsp;\u2014 \u6839\u636e\u7cfb\u7edf\u80fd\u9700\u6c42\u81ea\u52a8\u8c03\u8282\u6863\u4f4d\uff0c\u8282\u80fd\u3001\u9759\u97f3<\/li>\n<li><strong>\u535a\u4e16\u81ea\u4e3b\u7814\u53d1Heatronic III\u667a\u80fd\u63a7\u5236\u5668<\/strong>&nbsp;\u2014 \u7ed3\u5408\u5927\u9762\u79ef\u677f\u5f0f\u6362\u70ed\u5668\u548c\u9ad8\u7cbe\u5ea6\u6d41\u91cf\u4f20\u611f\u5668\u7cbe\u786e\u63a7\u5236\u751f\u6d3b\u70ed\u6c34\u6c34\u6e29<\/li>\n<li><strong>\u8d85\u5927\u677f\u5f0f\u6362\u70ed\u5668<\/strong>&nbsp;\u2014 \u8d85\u5927\u9762\u79ef\u4e0d\u9508\u94a2\u677f\u5f0f\u6362\u70ed\u5668\uff0c\u751f\u6d3b\u70ed\u6c34\u6362\u70ed\u8fc5\u901f\uff0c\u6e29\u5ea6\u66f4\u7a33\u5b9a<\/li>\n<li><strong>\u535a\u4e16\u70ed\u6c34\u7cfb\u7edf<\/strong>&nbsp;\u2014 16kg\/min\u4ea7\u70ed\u91cf\uff0c\u91cd\u65b0\u5b9a\u4e49\u4e16\u535a25kW\u70ed\u6c34\u6807\u51c6\uff1b25KW\u91c7\u6696\u7089\u9001\u53d116kg\/min\u70ed\u6c34\u91cf\uff0c\u8f83\u4e0a\u4e00\u4ee3\u70ed\u6c34\u6d41\u91cf\u63d0\u534725%<\/li>\n<\/ol>\n<h4 class=\"wp-block-heading\">4\ufe0f\u20e3 \u535a\u4e16\u6052\u6e29\u63a7\u7130\u6280\u672f<\/h4>\n<p class=\"wp-block-paragraph\">\u7cfb\u7edf\u63a7\u5236 \u667a\u80fd\u4e92\u8054 \u6052\u6e29\u8212\u9002 \u9ad8\u6548\u8282\u80fd<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5c06\u58c1\u6302\u7089\u706b\u7130\u63a7\u5236\u4e0e\u623f\u95f4\u6e29\u5ea6\u5b8c\u7f8e\u7ed3\u5408<\/li>\n<li>\u6839\u636e\u5f53\u524d\u623f\u95f4\u6e29\u5ea6\u8bbe\u5b9a\u6e29\u5ea6\u7684\u504f\u5dee\uff0c\u81ea\u52a8\u8c03\u8282\u58c1\u6302\u7089\u51fa\u6c34\u6e29\u5ea6\u548c\u58c1\u6302\u7089\u706b\u529b\u5927\u5c0f\uff0c\u4f7f\u623f\u95f4\u6e29\u5ea6\u7a33\u5b9a\u5728\u8bbe\u5b9a\u6e29\u5ea6<\/li>\n<li>\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u51cf\u5c11\u5c11\u542f\u505c\u6b21\u6570\uff0c\u63d0\u9ad8\u6574\u4e2a\u91c7\u6696\u7cfb\u7edf\u7684\u7a33\u5b9a\u6027<\/li>\n<\/ul>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"cpxlxj\" class=\"wp-block-heading\">\u4e09\u3001\u4ea7\u54c1\u7cfb\u5217\u8be6\u89e3<\/h2>\n<h3 class=\"wp-block-heading\">\ud83c\udfc6 \u65d7\u8230\u7cfb\u5217<\/h3>\n<h4 class=\"wp-block-heading\">CONDENS 9000I WM \u2014 \u535a\u4e16\u65d7\u8230\u6b3e\u96c6\u6210\u51b7\u51dd\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\uff0c\u81f3\u81fb\u8212\u9002\u4eab\u53d7<\/li>\n<li><strong>\u9002\u7528\u573a\u666f<\/strong>\uff1a\u96c5\u5962\u8c6a\u5b85\u4e4b\u9009\uff0c\u89d2\u843d\u6536\u7eb3\uff0c\u8282\u7701\u7a7a\u95f4\uff0c\u53ef\u7075\u6d3b\u5b89\u88c5\u5728\u53a8\u623f\u3001\u5ba2\u5385\u7b49\u5904<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u535a\u4e16DNA\u8bbe\u8ba1<\/strong>\uff1a\u5f02\u7279\u73bb\u7483\u9762\u677f\uff08\u8010\u6e29\u9632\u6f6e\uff0c\u9ad8\u96c5\u65f6\u5c1a\uff09\uff1b\u5706\u89d2\u8bbe\u8ba1\u5212\u7b56\uff08\u67d4\u548c\u9632\u649e\uff0c\u7cbe\u81f4\u7f8e\u89c2\uff09\uff1b\u6781\u7b80\u7528\u6237\u754c\u9762\uff08\u667a\u80fd\u64cd\u4f5c\uff0c\u79d1\u6280\u8d28\u611f\uff09<\/li>\n<li><strong>CMS\u71c3\u70e7\u7ba1\u7406\u7cfb\u7edf<\/strong>\uff1a\u535a\u4e16\u6700\u65b0\u4e00\u4ee3CMS\u71c3\u70e7\u7ba1\u7406\u7cfb\u7edf\uff0c\u53ef\u4ece10%-100%\u53d8\u8c03\u8282\u706b\u529b\uff0c\u6700\u5c0f\u706b\u529b\u53ef\u964d\u81f33kW\uff08\u4ecd\u6ee1\u8db3\u5730\u677f\u91c7\u6696\u4fdd\u6e29\u65f6\u7684\u8f83\u5c0f\u52a0\u70ed\u9700\u6c42\uff09\uff0c\u6e29\u5ea6\u8f93\u51fa\u66f4\u7a33\u5b9a\u7cbe\u51c6\uff0c\u91c7\u6696\u66f4\u5177\u9ad8\u8212\u9002\u5ea6<\/li>\n<li><strong>\u667a\u80fd\u6e29\u63a7\u5668CW400<\/strong>\uff1a\u81ea\u52a8\u611f\u5e94\u663c\u591c\u6e29\u5dee\u53ca\u5ba4\u5185\u6e29\u5ea6\u53d8\u5316\uff0c\u8ba1\u7b97\u5e76\u8c03\u8282\u9002\u5408\u5f53\u524d\u7684\u91c7\u6696\u6e29\u5ea6<\/li>\n<li><strong>WB5\u7ffc\u7fc5\u6c34\u51b7\u6362\u70ed\u5668<\/strong><\/li>\n<li><strong>\u9002\u4eab\u7545\u5feb\"\u6d17\"\u60a6<\/strong>\uff1a\u8d85\u539a\u5927\u677f\u5f0f\u6362\u70ed\u5668\uff0c\u5feb\u901f\u8fbe\u5230\u9884\u8bbe\u70ed\u5ea6\uff0c\u9884\u70ed\u65e0\u9700\u7b49\u5f85\uff1b\u5185\u7f6e150L\u5206\u5c42\u6c34\u7bb1\uff0c\u5236\u70ed\u8fc5\u901f\uff0c\u53ef\u652f\u6301\u540c\u4e00\u65f6\u6bb5\u591a\u4e2a\u70ed\u6c34\u9f99\u5934\u5904\u4e8e\u5f00\u542f\u72b6\u6001<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>GC 9000I WM \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">GC 9000I WM<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u529f\u7387\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>30.8<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>29.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>36.0<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa(30)\u00b0C<\/td>\n<td>kW<\/td>\n<td>9.5<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8d1f\u8377<\/td>\n<td>kW<\/td>\n<td>35.0<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c1413T<\/td>\n<td>m\u00b3\/h<\/td>\n<td>3.7<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14\u538b\u529b<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b\u9002\u7528\u8303\u56f4<\/td>\n<td>Pa<\/td>\n<td>1500-3000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u6c14\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90<\/td>\n<td>-<\/td>\n<td>1~<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u8def<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u6c34\u91cf(L\u2084\u2080=30\u2103)<\/td>\n<td>l\/h<\/td>\n<td>2.4<\/td>\n<\/tr>\n<tr>\n<td>PH\u503c<\/td>\n<td>-<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u6c34\u50a8\u7f50<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6709\u6548\u5bb9\u91cf<\/td>\n<td>L<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6e29\u5ea6<\/td>\n<td>\u00b0C<\/td>\n<td>40-60<\/td>\n<\/tr>\n<tr>\n<td>\u4ea7\u7387\u91cf(\u25b3t=25K)<\/td>\n<td>l\/min<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u70ed<\/td>\n<td>kWh\/m\u00b3<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b(Pmax)<\/td>\n<td>bar<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u7c7b\u522b(\u5929\u7136\u6c1413T\u6216LPG=40\u2103)<\/td>\n<td>-<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<td><strong>\u80fd\u8017<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u529f\u8017(\u5f85\u673a)<\/td>\n<td>W<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u529f\u8017(\u4f9b\u6696)<\/td>\n<td>W<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u4fdd\u62a4\u88c5\u7f6e<\/td>\n<td>-<\/td>\n<td>(IP40)<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u5faa\u73af\u6cf5\u6700\u5927\u529f\u7387(W)\u3010...\u3011<\/td>\n<td>\u00b0C<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u6700\u5927\u8fd0\u884c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u56de\u6c34\u6700\u9ad8\u6e29\u5ea6(\u4e0a\u9650)<\/td>\n<td>\u00b0C<\/td>\n<td>0-40<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u5305\u62ec\u9644\u4ef6)<\/td>\n<td>kg<\/td>\n<td>130<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>1820x600x670<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h4 class=\"wp-block-heading\">CONDENS 8700I W \u2014 \u51b7\u51dd\u5f0f\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5fb7\u56fd\u8fdb\u53e3\uff0c\u6c22\u80fd\u5c31\u7eea*\uff1b\u4e13\u4e3a\u522b\u5885\/\u5927\u5e73\u5c42\u9ad8\u7aef\u7528\u6237\u5b9a\u5236<\/li>\n<li><strong>Slogan<\/strong>\uff1a\u70ed\u6c34\u5927\u5347\u4f4d \u91c7\u6696\u6d17\u6d74\u53cc\u4eab\u53d7<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u91d1\u5c5e\u7ea4\u7ef4\u9884\u7f6e\u5f0f\u71c3\u70e7\u5668<\/strong>\uff1a\u66f4\u8010\u7528\uff0c\u5012\u7f6e\u706b\u70ae\uff0c\u8150\u8680\u6027\u51b7\u51dd\u6c34\u4e0d\u4f1a\u63a5\u89e6\u71c3\u70e7\u5668\uff0c\u589e\u957f\u5bff\u547d<\/li>\n<li><strong>\u94f8\u7845\u94dd\u4e3b\u70ed\u4ea4\u6362\u5668<\/strong>\uff1a\u6b27\u6d32\u5236\u9020\u4e13\u5229\uff0c\u7845\u94dd\u5408\u91d1\u4e00\u4f53\u94f8\u9020\u6210\u578b\uff0c\u65e0\u710a\u70b9\uff0c\u65e0\u60e7\u6f0f\u6c34\u98ce\u9669<\/li>\n<li><strong>\u6ee1\u8db315\u5e74\u8bbe\u8ba1\u5bff\u547d\u73af\u4fdd\u6750\u6599\u8981\u6c42<\/strong>*<\/li>\n<li>\u7ea6108%**\u8d85\u9ad8\u70ed\u6548\u7387\uff08\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a\uff09<\/li>\n<li>\u535a\u4e16\u6052\u6e29\u63a7\u7130\u6280\u672f + \u5ba4\u5916\u8865\u507f\u529f\u80fd<\/li>\n<li><strong>22L\u5927\u5347\u4f4d\u6ee1\u8db3\u53cc\u536b\u70ed\u6c34\u540c\u65f6\u4f7f\u7528\u9700\u6c42<\/strong>\uff1b3\u661f\u9ad8\u70ed\u6c34\u54c1\u8d28**<\/li>\n<li>\u5feb\u901f\u62c6\u5378-20s \u76f4\u8fbe\u673a\u5668\u5185\u90e8\uff1b\u6781\u7b80\u7ef4\u62a4-\u7eff\u8272\u4ea4\u4e92\u90e8\u4ef6\uff0c\u6781\u7ebf\u5feb\u901f\u9501\u5b9a\u62c6\u5378\uff1b\u7279\u522b\u8bbe\u8ba1\u7684\u827e\u74e6\u91cc\u8c03\u8282\u88c5\u7f6e\uff0c\u65e0\u9700\u7e41\u7410\u8c03\u8bd5<\/li>\n<li><strong>50\u4f59\u91cd\u5b89\u5168\u4fdd\u969c<\/strong>\uff0c\u4e13\u4e1a\u5b88\u62a4\uff0c\u53ef\u9760\u8010\u7528<\/li>\n<li><strong>\u9759\u8c27\u8fd0\u884c<\/strong>\uff1a\u7279\u6b8a\u7ed3\u6784\u8bbe\u8ba1\uff0c\u963b\u9694\u566a\u97f3\uff0c\u8212\u4eab\u9759\u8c27<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>CONDENS 8700I W \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1GBO24-GC8700WM 24kW-C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1GBO34-GC8700WM 35kW-C<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>23.8-24.5<\/td>\n<td>33.0-33.5<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>21.3-21.4<\/td>\n<td>29.3-29.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>28.0<\/td>\n<td>38.0<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa\u8303\u56f4<\/td>\n<td>kW<\/td>\n<td>5.1-5.4<\/td>\n<td>6.1-6.8<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8d1f\u8377<\/td>\n<td>kW<\/td>\n<td>31.4-31.6<\/td>\n<td>34.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u7a7a\u6c14\u91cf(\u5929\u7136\u6c1413T)<\/td>\n<td>m\u00b3\/h<\/td>\n<td>6.3<\/td>\n<td>8.3<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa<\/td>\n<td>1,500-3,000<\/td>\n<td>1,500-3,000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u8def<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6d41\u91cf\u8bbe\u5b9a\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>10-88<\/td>\n<td>10-88<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u989d\u5b9a\u8303\u56f4<\/td>\n<td>L<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u4ea7\u6c34\u91cf(\u0394t=25K)<\/td>\n<td>kg\/min<\/td>\n<td>22.0<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51fa\u6c34\u6e29\u5ea6\u8bbe\u7f6e\u8303\u56f4<\/td>\n<td>\u00b0C<\/td>\n<td>35-60<\/td>\n<td>35-60<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf\u914d\u7f6e<\/td>\n<td>kg\/min<\/td>\n<td>51.9<\/td>\n<td>55-60<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u51fa\u6c34\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u51fa\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14(\u63a5\u71c3\u6c14)\u6e29\u5ea6\u8303\u56f4(40\/30\u00b0C)<\/td>\n<td>\u2103<\/td>\n<td>57\/M<\/td>\n<td>57\/M<\/td>\n<\/tr>\n<tr>\n<td>NOx\u7b49\u7ea7<\/td>\n<td>mg\/kWh<\/td>\n<td>5<\/td>\n<td>\u2264120<\/td>\n<\/tr>\n<tr>\n<td>\u6392\u70df\u53e3<\/td>\n<td>mm<\/td>\n<td>60\/130<\/td>\n<td>60\/130<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u6c34\u91cf(\u0394t=30\u2103)<\/td>\n<td>l\/h<\/td>\n<td>4.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90<\/td>\n<td>AC..V<\/td>\n<td>~220V\/50Hz<\/td>\n<td>~220V\/50Hz<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u5bb9(\u91c7\u6696\u7c7b\u4f9b\u70ed\u91cf)<\/td>\n<td>W<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7(\u4f9b\u6696)<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>50<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>840x370x365<\/td>\n<td>840x430x365<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 class=\"wp-block-heading\">\u2b50 \u9ad8\u7aef\u7cfb\u5217<\/h3>\n<h4 class=\"wp-block-heading\">CONDENS 7100 W \u2014 \u5fb7\u56fd\u97e6\u5c14\u7459\u5de5\u5382\u539f\u88c5\u8fdb\u53e3<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>\u5b9a\u4f4d<\/strong>\uff1a\u5168\u7403\u9500\u91cf\u8d85\u8fc7160\u4e07\u53f0*\uff1b\u5de5\u4e1a4.0\u5236\u9020\u5de5\u5382\uff0c\u751f\u4ea7\u65b9\u5f0f\u5168\u7ebf\u667a\u80fd\u5316\uff1b\u6570\u5b57\u5316\u8ddf\u8e2a\u751f\u4ea7\u7ec6\u8282\uff0c\u81ea\u52a8\u6545\u969c\u6392\u67e5\uff0c\u54c1\u8d28\u6709\u4fdd\u969c<\/li>\n<li><strong>\u516b\u5927\u6838\u5fc3\u6280\u672f<\/strong>\uff08\u540c\u4e0a\uff09<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>CONDENS 7100 W \u6280\u672f\u53c2\u6570\u8868\uff08\u5b8c\u6574\u7248\uff09<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 24<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 26\/30C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W MC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 35<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 37C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W 39<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">OC 7100W EM<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>27.4<\/td>\n<td>28.7<\/td>\n<td>29.8<\/td>\n<td>32.5<\/td>\n<td>35.4<\/td>\n<td>37.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>26.1<\/td>\n<td>24.5<\/td>\n<td>29.4<\/td>\n<td>34.1<\/td>\n<td>34.1<\/td>\n<td>37.2<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>27.4<\/td>\n<td>28.2<\/td>\n<td>30.4<\/td>\n<td>36.4<\/td>\n<td>35.4<\/td>\n<td>38.4<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>8.5<\/td>\n<td>9.3<\/td>\n<td>9.4<\/td>\n<td>14.5<\/td>\n<td>11.5<\/td>\n<td>14.5<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>30.0<\/td>\n<td>30.0<\/td>\n<td>30.0<\/td>\n<td>34.3<\/td>\n<td>34.3<\/td>\n<td>34.3<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf\u8303\u56f4<\/td>\n<td>kW<\/td>\n<td>30.4<\/td>\n<td>30.4<\/td>\n<td>30.4<\/td>\n<td>35.4<\/td>\n<td>35.4<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c14(L3T)<\/td>\n<td>m\u00b3\/h<\/td>\n<td>3.9<\/td>\n<td>3.2<\/td>\n<td>3.2<\/td>\n<td>3.7<\/td>\n<td>4.1<\/td>\n<td>4.1<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa\/h<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u8212\u9002\u6c34\u6d41\u91cf<\/td>\n<td>L<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6d41\u91cf(\u0394t=25K)<\/td>\n<td>Ag\/min<\/td>\n<td>-<\/td>\n<td>16.2<\/td>\n<td>18.2<\/td>\n<td>-<\/td>\n<td>23.0<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6d41\u91cf\u8303\u56f4<\/td>\n<td>\u00b0C<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<td>40-80<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b(Pmax)<\/td>\n<td>bar<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>NOx\u7b49\u7ea7(\u71c3\u6c14\u7c7b\u578b40\/30\u00b0C)<\/td>\n<td>\u2103<\/td>\n<td>51\/52<\/td>\n<td>59\/53<\/td>\n<td>51\/52<\/td>\n<td>60\/53<\/td>\n<td>69\/53<\/td>\n<td>69\/53<\/td>\n<\/tr>\n<tr>\n<td>\u6392\u70df\u53e3<\/td>\n<td>mm<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<td>65\/63<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u6c34\u91cf(\u0394t=30\u00b0C)<\/td>\n<td>l\/h<\/td>\n<td>2.2<\/td>\n<td>2.4<\/td>\n<td>3.4<\/td>\n<td>2.9<\/td>\n<td>3.5<\/td>\n<td>3.5<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u5bb9<\/td>\n<td>W<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<td>85\/85<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<td>850x440x350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h4 class=\"wp-block-heading\">\u6b27\u6d32\u8d35\u65cf \u2014 \u51b7\u51dd\u5f0f\u71c3\u6c14\u6696\u6d74\u4e24\u7528\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u8d8a\u7ea7\u84dd\u7ed2\u7130 \u51b7\u51dd\u5927\u70ed\u6c34<\/li>\n<li><strong>\u70ed\u6c34\u7cfb\u7edf\u4eae\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li id=\"ouzhou-guizu\"><strong>\u6dfb\u5347\u6709\u91cf \u53cc\u536b\u65e0\u5fe7<\/strong>\uff1a16kg\/min\u4ea7\u70ed\u6c34\u91cf\uff0c\u91cd\u65b0\u5b9a\u4e49\u535a\u4e1625kW\u70ed\u6c34\u6807\u51c6\uff1b25kW\u91c7\u6696\u7089\u9001\u53d116kg\/min\u70ed\u6c34\u91cf\uff0c\u4ea7\u6c34\u7387\u8d85\u5e45\u589e\u540c\u5e73\u53f025%\uff0c\u8f83\u4e0a\u4e00\u4ee3\"\u70ed\u6c34\u91cf\u63d0\u534725%\"<\/li>\n<li><strong>\u83b7\u5f97\u6b27\u6d32\u4e09\u661f\u8212\u9002\u70ed\u6c34\u8ba4\u8bc1<\/strong><\/li>\n<li><strong>CHG\u6c34\u529b\u7ec4\u4ef6\u5168\u9762\u5347\u7ea7<\/strong>\uff1a\u677f\u5f0f\u6362\u70ed\u5668\u4f53\u79ef\u8f83\u4e0a\u4e00\u4ee3\u589e\u52a030%<\/li>\n<li><strong>\u9ad8\u5ea6\u6da1\u8f6e\u8f6e\u6d41\u91cf\u4f20\u611f\u5668<\/strong>\uff1a\u5185\u7f6e\u7075\u654f\u7684\u78c1\u8f6c\u5b50\uff0c\u5728\u6781\u5c0f\u6d41\u91cf\u4e0b\u4e5f\u80fd\u8f6c\u52a8\uff0c\u9ad8\u7075\u654f\u4f20\u611f\u5668\u53ef\u611f\u77e5\u6781\u5c0f\u7684\u6c34\u6d41\u53d8\u5316<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u71c3\u70e7\u7cfb\u7edf<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5546\u7528\u71c3\u70e7\u5668 \u66f4\u8010\u7528\uff08\u84dd\u8574\u706b\u7130\uff0c\u5c0f\u4f53\u79ef\u5927\u80fd\u91cf\uff09<\/li>\n<li>\u9ad8\u80fd\u6548 \u66f4\u8282\u80fd\uff08\u5168\u9884\u6df7\u5408\u51b7\u51dd\u71c3\u70e7\u6280\u672f\uff0c\u667a\u80fd\u8c03\u8282\u70ed\u8d1f\u8377\uff0c\u7ea6108%\u8d85\u9ad8\u70ed\u6548\u7387\uff09<\/li>\n<li>\u65e0\u710a\u70b9 \u66f4\u575a\u56fa\uff08\u535a\u4e16\u4e13\u5229WB5\u7845\u94dd\u5408\u91d1\u6362\u70ed\u5668\uff0c\u4e00\u4f53\u6210\u578b\uff09<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u6b27\u6d32\u8d35\u65cf \u6280\u672f\u53c2\u6570\u8868<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">25kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">25kW \u5546\u5c45\u4e24\u7528(2020\/2023)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">25kW \u4e24\u7528\u7089(2020\/2023)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">25kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u5546\u5c45\u4e24\u7528(2020\/2023)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u4e24\u7528\u7089(2020\/2023)<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u4e24\u7528\u7089<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u63cf\u8ff0<\/strong><\/td>\n<td>L1JF020\/1(DNW020\/1)(DNW020\/1A)<\/td>\n<td>L1JF020Z1\/DNZ020\/1A<\/td>\n<td>L1JF020Z1\/DNZ020\/1A<\/td>\n<td>L1JF020Z1\/DNZ020\/1A<\/td>\n<td>L1JF034\/DNZ034<\/td>\n<td>L1JF034Z1(DNW034\/1)(DNW034\/1A)<\/td>\n<td>L1JF034Z1\/DNZ034\/1A<\/td>\n<td>L1JF034Z1\/DNZ034\/1A<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8d1f\u8377<\/td>\n<td>kW<\/td>\n<td>20.3<\/td>\n<td>27.4<\/td>\n<td>30.4<\/td>\n<td>36.4<\/td>\n<td>36.4<\/td>\n<td>39.4<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>6.2<\/td>\n<td>6.5<\/td>\n<td>6.5<\/td>\n<td>9.2<\/td>\n<td>9.2<\/td>\n<td>9.2<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>20.3<\/td>\n<td>27.4<\/td>\n<td>30.6<\/td>\n<td>36.5<\/td>\n<td>36.6<\/td>\n<td>39.4<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>24.5<\/td>\n<td>26.1<\/td>\n<td>26.4<\/td>\n<td>34.1<\/td>\n<td>37.2<\/td>\n<td>37.2<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u989d\u5b9a\u8303\u56f4(30\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>7.1<\/td>\n<td>7.1<\/td>\n<td>10.1<\/td>\n<td>10.1<\/td>\n<td>10.1<\/td>\n<td>10.1<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u989d\u5b9a\u8303\u56f4(50\/80\u00b0C)<\/td>\n<td>kW<\/td>\n<td>6.4<\/td>\n<td>6.4<\/td>\n<td>9.3<\/td>\n<td>9.3<\/td>\n<td>9.3<\/td>\n<td>9.3<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u6392\u70df<\/td>\n<td>\u56fd\u68071\u7ea7\/\u56fd\u68072\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68072\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u6c34\u91cf<\/td>\n<td>W<\/td>\n<td>115<\/td>\n<td>115<\/td>\n<td>140<\/td>\n<td>140<\/td>\n<td>150<\/td>\n<td>175<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u57fa\u672c\u8017\u7535\u91cf<\/td>\n<td>W<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<td>93<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u6700\u5927\u9002\u7528\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u70ed\u529b<\/td>\n<td>L<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>-<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u6700\u5927\u4ea7\u51fa\u80fd\u529b<\/td>\n<td>kW<\/td>\n<td>36<\/td>\n<td>-<\/td>\n<td>34.3<\/td>\n<td>38<\/td>\n<td>38<\/td>\n<td>-<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5236\u70ed\u4ea7\u6c34\u91cf\u8303\u56f4(\u0394t=25 K)<\/td>\n<td>kg\/kWh<\/td>\n<td>16.2<\/td>\n<td>16.2<\/td>\n<td>13<\/td>\n<td>21<\/td>\n<td>21<\/td>\n<td>-<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-60<\/td>\n<td>40-60<\/td>\n<td>40-60<\/td>\n<td>40-60<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u4f9b\u6c34\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>-<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u51fa\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.2<\/td>\n<td>0.2<\/td>\n<td>0.2<\/td>\n<td>0.2<\/td>\n<td>0.2<\/td>\n<td>-<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u79cd\u7c7b(\u5929\u7136\u6c1412T\/11T)<\/td>\n<td>mPa\/Ts<\/td>\n<td>5.2<\/td>\n<td>2.9<\/td>\n<td>9.7<\/td>\n<td>9.7<\/td>\n<td>6.3<\/td>\n<td>4.1<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td>3,000<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u4ea7\u6c34\u91cf(\u0394t=25K)<\/td>\n<td>L\/mn<\/td>\n<td>2.4<\/td>\n<td>2.4<\/td>\n<td>2.9<\/td>\n<td>2.9<\/td>\n<td>3.5<\/td>\n<td>3.5<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>pH\u503c<\/td>\n<td>-<\/td>\n<td>4.8<\/td>\n<td>4.8<\/td>\n<td>4.8<\/td>\n<td>4.8<\/td>\n<td>4.8<\/td>\n<td>4.8<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>NOx(\u6beb\u514b\u65e0\u9650\u5236\u6392\u653e)<\/td>\n<td>-<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td>\u56fd\u68071\u7ea7<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>53<\/td>\n<td>58<\/td>\n<td>62<\/td>\n<td>62<\/td>\n<td>63<\/td>\n<td>64<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>850x455x350<\/td>\n<td>850x455x320<\/td>\n<td>850x450x320<\/td>\n<td>850x450x320<\/td>\n<td>850x450x320<\/td>\n<td>850x450x320<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 class=\"wp-block-heading\">\ud83c\udde9\ud83c\uddea \u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\u7cfb\u5217<\/h3>\n<h4 class=\"wp-block-heading\">G8550I W \u2014 \u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u5168\u6c14\u5019\u6052\u6e29 \u9759\u4eab8\u7cfb\u8c6a\u534e<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u5168\u6c14\u5019\u6052\u6e29\u6280\u672f<\/strong>\uff08\u56db\u5b63\u8212\u723d\u6d17\u6fa1\uff09\uff1a\n<ul class=\"wp-block-list\">\n<li>\u6f6e\u6c50\u706b\u6392\uff0c\u5206\u89c4\u71c3\u70e7Plus<\/li>\n<li>\u8fdb\u51fa\u6c34\u53cc\u6e29\u611f\uff0c\u7cbe\u51c6\u8c03\u8282<\/li>\n<li>\u535a\u4e16\u4e13\u5229\u6052\u6e29\u6280\u672f<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u535a\u4e16\u7b2c4\u4ee3\u70ed\u80fd\u82af<\/strong>\uff1aEMS2.0\u5168\u65b0\u81ea\u7814\u7b97\u6cd5\uff0c\u806a\u660e\u7701\u6c14\uff1b\u53ef\u4e0e\u535a\u4e16\u667a\u80fd\u63a7\u5236\u5668MR\u7cfb\u5217\u7b49\u5339\u914d<\/li>\n<li><strong>\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3<\/strong>\uff1a\u667a\u80fd\u5236\u90204.0\u4ea7\u7ebf<\/li>\n<li><strong>\u535a\u4e16DNA\u8bbe\u8ba1\u5916\u89c2<\/strong>\uff08\u7d27\u51d1\u5c0f\u5de7\u89e6\u611f\u64cd\u63a7\uff09\uff1a\u667a\u80fd\u81ea\u52a8\u53164.0\u4ea7\u7ebf<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>G8550i W \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YPS-G8550W 24C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YP-G8550WN2C<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YPP-G8550WN2<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1YPL-G8550WN2<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u989d\u5b9a\u8303\u56f4(50\/80)\u00b0C<\/td>\n<td>kW<\/td>\n<td>26.4<\/td>\n<td>20.7<\/td>\n<td>26.4<\/td>\n<td>20.7<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>28<\/td>\n<td>28<\/td>\n<td>28<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>3.8<\/td>\n<td>3.9<\/td>\n<td>3.8<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf\u8303\u56f4<\/td>\n<td>kW<\/td>\n<td>26.6<\/td>\n<td>26.6<\/td>\n<td>26.6<\/td>\n<td>26.6<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c14(L3T)<\/td>\n<td>m\u00b3\/h<\/td>\n<td>26.4(12T)<\/td>\n<td>26.7(12T)<\/td>\n<td>26.4(12T)<\/td>\n<td>26.7(12T)<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u538b\u529b(\u9002\u7528\u8303\u56f4)<\/td>\n<td>Pa<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<td>1500-3000<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b<\/td>\n<td>Pa<\/td>\n<td>2000<\/td>\n<td>2000<\/td>\n<td>2000<\/td>\n<td>2000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u5bb9<\/td>\n<td>W<\/td>\n<td>190<\/td>\n<td>190<\/td>\n<td>190<\/td>\n<td>190<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u51c0\u91cd)<\/td>\n<td>kg<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>682x367x776<\/td>\n<td>682x367x776<\/td>\n<td>682x367x778<\/td>\n<td>682x367x778<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">*\u6570\u636e\u6765\u6e90\u4e8eG8550WN2\u89c4\u683c\u4e66<\/p>\n<\/blockquote>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 class=\"wp-block-heading\">\u7ecf\u5178\u54c1\u8d28\u7cfb\u5217<\/h3>\n<h4 class=\"wp-block-heading\">\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248 \u2014 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u7ecf\u5178\u54c1\u8d28\uff0c\u65e0\u5fe7\u4e4b\u9009<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u7ea6<strong>93%<\/strong>*\u8d85\u9ad8\u70ed\u6548\u7387\uff0c\u8282\u7701\u71c3\u6c14\u5f00\u652f<\/li>\n<li>\u4f4e\u566a\u8fd0\u884c\uff08\u53cc\u901f\u98ce\u673a+\u53d8\u9891\u6c34\u6cf5\uff0c\u53ef\u4f20\u673a\u5668\u4f4e\u901f\u8fd0\u8f6c\uff09<\/li>\n<li>\u5feb\u51fa\u5145\u6c9b\u70ed\u6c34\uff08\u5145\u6d74\u70ed\u6c34\u4f9b\u5e94\uff0c\u6ee1\u8db3\u5927\u82b1\u6d12\u6d41\u91cf\u8981\u6c42\uff09<\/li>\n<li><strong>\u8d85\u8fc7100\u4e07\u53f0<\/strong>\u5168\u7403\u5b89\u5168\u8fd0\u884c\uff08\u81ea2001\u5e74\u5728\u6b27\u6d32\u4e0a\u5e02\uff0c\u5168\u7403\u9500\u91cf\u7d2f\u8ba1\u7a81\u7834100\u4e07\u53f0\uff09<\/li>\n<li><strong>10\u5e74<\/strong>\u7545\u9500\u4e2d\u56fd\uff08\u622a\u81f32022\u5e7412\u6708\uff09<\/li>\n<li><strong>10\u9879<\/strong>\u91cd\u5b89\u5168\u4fdd\u969c\uff08\u4f9b\u70ed\u56de\u8def\u4f4e\u538b\u4fdd\u62a4\u3001\u70df\u6c14\u76d1\u6d4b\u5173\u95ed\u3001\u751f\u6d3b\u70ed\u6c34\u6c34\u91cf\u76d1\u6d4b\u3001\u71c3\u6c14\u5b89\u5168\u4fdd\u62a4\u3001\u5b89\u5168\u6cc4\u538b\u4fdd\u62a4\u3001\u4f9b\u6696\u6c34\u6e29\u76d1\u6d4b\u3001\u6545\u969c\u76d1\u6d4b\/\u91cd\u9501\u3001\u8d85\u6e29\u4fdd\u62a4\u3001\u71c3\u70e7\u5ba4\u76d1\u6d4b\u3001\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\u76d1\u6d4b\uff09<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248 \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">24kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">24kW \u7cfb\u5217\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">28kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">28kW \u7cfb\u5217\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u4e24\u7528\u7089<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">35kW \u7cfb\u5217\u7089<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u63cf\u8ff0<\/td>\n<td>L1JP27-ZWCW24-NJP23-ZWCW24G<\/td>\n<td>L1JP27-ZWCW24G<\/td>\n<td>L1JP23-ZWCW28G<\/td>\n<td>L1JP23-ZWCW28G-L1JP23-ZWCW28G<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u79cd\u7c7b<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u5165(\u91c7\u6696)<\/td>\n<td>kW<\/td>\n<td>26.7<\/td>\n<td>26.7<\/td>\n<td>31.3<\/td>\n<td>31.3<\/td>\n<td>38.3<\/td>\n<td>38.3<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa(\u4e24\u7528)<\/td>\n<td>kW<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>28.1<\/td>\n<td>28.1<\/td>\n<td>34.9<\/td>\n<td>34.9<\/td>\n<\/tr>\n<tr>\n<td>\u7ec6\u8c03\u7cfb\u7edf\u5141\u8bb8\u7684\u6700\u5927\u538b\u529b(Pmax)<\/td>\n<td>bar<\/td>\n<td>3.0<\/td>\n<td>3.0<\/td>\n<td>3.0<\/td>\n<td>3.0<\/td>\n<td>3.0<\/td>\n<td>3.0<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u9ad8\u56de\u6c34\u6e29\u5ea6<\/td>\n<td>\u2103<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<td>40-60<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u5de5\u4f5c\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<td>0.02<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b(\u5929\u7136\u6c1412T)<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u542b\u5305\u88c5)<\/td>\n<td>kg<\/td>\n<td>41<\/td>\n<td>41<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>46<\/td>\n<td>46<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u6df1)<\/td>\n<td>mm<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<td>850x400x370<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h4 class=\"wp-block-heading\">G7\u955c\u9762\u7248 \u2014 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u6709\u989c\u6709\u54c1 \u5c3d\u5584\u9759\u7f8e \/ \u8ba9\u5149\u5f69\uff0c\u70b9\u4eae\u6e29\u6696\u751f\u6d3b\uff01<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5149\u5f71\u73bb\u7483\u9762\u677f\uff0c\u7edd\u7f8e\u6297\u6cb9\u6c61<\/li>\n<li>\u4e00\u7ea7\u9759\u97f3*\uff0c\u9759\u4eab\u6e29\u6696<\/li>\n<li>\u4e13\u5229**\u63a7\u6e29\u6280\u672f\uff0c\u6781\u901f\u54cd\u5e94\uff0c\u6052\u6e29\u8212\u9002<\/li>\n<li>\u4e13\u5229**\u6392\u70df\u8bbe\u8ba1\uff0c\u6297\u5f3a\u98ce\u7b97\u6cd5\uff0c\u4e0d\u60e7\u5f3a\u98ce\u4fb5\u88ad\uff0c\u6e29\u6696\u4e0d\u505c<\/li>\n<li>\u642d\u914dMR\u7cfb\u5217\u667a\u80fd\u6e29\u63a7\uff0cwifi\u64cd\u4f5c\uff0c\u7701\u5fc3\u7701\u6c14<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>G7\u955c\u9762\u7248 &amp; G7\u955c\u9762\u7248(\u4e24\u7528) \u6280\u672f\u53c2\u6570\u5bf9\u6bd4<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">G7\u955c\u9762\u7248<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">G7\u955c\u9762\u7248<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u63cf\u8ff0<\/td>\n<td><\/td>\n<td>24kW \u4e24\u7528\u7089<\/td>\n<td>28kW \u4e24\u7528\u7089<\/td>\n<\/tr>\n<tr>\n<td>\u578b\u53f7<\/td>\n<td><\/td>\n<td>L1JP27-G7200W 24 CG<\/td>\n<td>L1JP31-G7200W 28 CG<\/td>\n<\/tr>\n<tr>\n<td>\u71c3\u6c14\u79cd\u7c7b<\/td>\n<td><\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<td>\u5929\u7136\u6c14<\/td>\n<\/tr>\n<tr>\n<td><strong>\u52a8\u529b<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5927\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>24<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5927\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>26.6<\/td>\n<td>31.1<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>7.4<\/td>\n<td>8.9<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u989d\u5b9a\u6700\u5c0f\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>8.6<\/td>\n<td>10.3<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u989d\u5b9a\u6700\u5927\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>26.6<\/td>\n<td>31.1<\/td>\n<\/tr>\n<tr>\n<td>\u80fd\u6548\u7b49\u7ea7<\/td>\n<td><\/td>\n<td>\u56fd\u68072\u7ea7<\/td>\n<td>\u56fd\u68072\u7ea7<\/td>\n<\/tr>\n<tr>\n<td><strong>\u91c7\u6696<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u7535\u529b\u7387<\/td>\n<td>W<\/td>\n<td>&lt;110<\/td>\n<td>&lt;120<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u51fa\u6c34\u6e29\u5ea6\u8bbe\u7f6e\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-82<\/td>\n<td>40-82<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u6696\u7cfb\u7edf\u5141\u8bb8\u7684\u6700\u5927\u5de5\u4f5c\u538b\u529b(Pmax)<\/td>\n<td>MPa<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u81a8\u80c0\u6c34\u7bb1<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u538b\u538b\u529b<\/td>\n<td>MPa<\/td>\n<td>0.05<\/td>\n<td>0.05<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u5bb9\u79ef<\/td>\n<td>L<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u79f0\u4ea7\u6c34\u901f\u7387(\u0394t=25 k)<\/td>\n<td>kg\/min<\/td>\n<td>13.0<\/td>\n<td>16.0<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51fa\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>35-60<\/td>\n<td>35-60<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u7cfb\u7edf\u4f7f\u7528\u6c34\u538b<\/td>\n<td>MPa<\/td>\n<td>0.03-1<\/td>\n<td>0.03-1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b(\u5929\u7136\u6c1412 T)<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e00\u822c\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90\u7535\u538b<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u6c34\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u542b\u5305\u88c5)<\/td>\n<td>kg<\/td>\n<td>33<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u539a)<\/td>\n<td>mm<\/td>\n<td>707.5x400x312<\/td>\n<td>707.5x400x312<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h3 class=\"wp-block-heading\">\u7ecf\u6d4e\u5b9e\u7528\u7cfb\u5217<\/h3>\n<h4 class=\"wp-block-heading\">G6300W \u2014 \u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089<\/h4>\n<ul class=\"wp-block-list\">\n<li><strong>Slogan<\/strong>\uff1a\u4e0d\u60e7\u4e25\u5bd2 \u6e29\u6696\u6709\u4f60<\/li>\n<li><strong>\u7279\u70b9<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u6781\u7aef\u73af\u5883\u901a\u7528\uff1a\u4e13\u4e3a<strong>\u4e2d\u56fd\u5e02\u573a<\/strong>\u8bbe\u8ba1\u7684G6300W\uff0c\u9002\u7528\u4e8e\u5317\u90e8\u4e25\u5bd2\u5730\u533a\u7684\u6c14\u5019\u6761\u4ef6<\/li>\n<li>\u5c0f\u8eab\u6750\u3001\u5927\u70ed\u6c34\uff1a\u517c\u5177\u8282\u80fd\u8212\u9002\uff0cG6300W\u53ef\u5728\u8f83\u5c0f\u91c7\u6696\u8d1f\u8377\u4e0b\u8fd0\u884c\uff0c\u4ee5\u8282\u7ea6\u71c3\u6c14<\/li>\n<li>\u8fd0\u884c\u566a\u97f3\u4ec5<strong>48dB(A)<\/strong>*<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><strong>G6300W \u6280\u672f\u53c2\u6570<\/strong>\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1JPB-G6300W 18\/18 CB<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">L1JP34-G6300W 22\/24 CG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u6700\u5927\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>18<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>17.9<\/td>\n<td>24.4<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>6.4<\/td>\n<td>7.4<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>6.3<\/td>\n<td>8.6<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>18<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u5165<\/td>\n<td>kW<\/td>\n<td>20.2<\/td>\n<td>28.7<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u91c7\u6696\u989d\u5b9a\u70ed\u8f93\u51fa<\/td>\n<td>kW<\/td>\n<td>8.3<\/td>\n<td>9.6<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u5929\u7136\u6c14(\u5929\u7136\u6c1412 T)<\/td>\n<td>-<\/td>\n<td>\u5929\u7136\u6c1412 T<\/td>\n<td>\u5929\u7136\u6c1412 T<\/td>\n<\/tr>\n<tr>\n<td>\u989d\u5b9a\u71c3\u6c14\u538b\u529b(\u5929\u7136\u6c1412T)<\/td>\n<td>Pa<\/td>\n<td>2,000<\/td>\n<td>2,000<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u71c3\u6c14\u538b\u529b(Min=3.5kW\/hr)<\/td>\n<td>m\/h<\/td>\n<td>2.12<\/td>\n<td>2.8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6c34\u8def<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6700\u5927\u538b\u529b<\/td>\n<td>Nf<\/td>\n<td>&lt;105<\/td>\n<td>&lt;105<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u989d\u5b9a\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>40-82<\/td>\n<td>40-82<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u6700\u5927\u5de5\u4f5c\u538b\u529b(P...)<\/td>\n<td>bar<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u80c0\u6c34\u7bb1\u5bb9\u79ef<\/td>\n<td>L<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>\u81a8\u80c0\u6c34\u7bb1\u9884\u7f6e\u538b\u529b(BN18031)<\/td>\n<td>-<\/td>\n<td>6<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u4ea7\u6c34\u91cf(GPM \u0394T=25K)<\/td>\n<td>kg\/min<\/td>\n<td>10<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u51fa\u6c34\u6e29\u5ea6\u8303\u56f4<\/td>\n<td>\u2103<\/td>\n<td>35-60<\/td>\n<td>35-60<\/td>\n<\/tr>\n<tr>\n<td>\u751f\u6d3b\u70ed\u6c34\u6700\u5927\u6d41\u91cf<\/td>\n<td>kg\/min<\/td>\n<td>49.60<\/td>\n<td>49.60<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u51fa\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>0.3<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u71c3\u6c14\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u6700\u9ad8\u70df\u6c14\u6e29\u5ea6\/\u70df\u5ea6<\/td>\n<td>\u2103<\/td>\n<td>169\/90<\/td>\n<td>179\/95<\/td>\n<\/tr>\n<tr>\n<td>NOx \u542b\u91cf<\/td>\n<td>mg\/kWh<\/td>\n<td>133<\/td>\n<td>132<\/td>\n<\/tr>\n<tr>\n<td>CO\u542b\u91cf<\/td>\n<td>-<\/td>\n<td>60\/100<\/td>\n<td>60\/100<\/td>\n<\/tr>\n<tr>\n<td>\u6392\u70df\u53e3\u5f84<\/td>\n<td>mm<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7535\u5668\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u5907\u7535\u6e90\u7535\u538b<\/td>\n<td>m\u00b2<\/td>\n<td>61\/500<\/td>\n<td>61\/500<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u989d\u5b9a\u6d41\u901f<\/td>\n<td>\u2103<\/td>\n<td>&gt;40<\/td>\n<td>&gt;40<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u989d\u5b9a\u626c\u7a0b<\/td>\n<td>m\u00b2\/H<\/td>\n<td>&gt;-20<\/td>\n<td>&gt;-20<\/td>\n<\/tr>\n<tr>\n<td><strong>\u4e00\u822c\u53c2\u6570<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u7535\u538b\u6e90<\/td>\n<td>AC..V<\/td>\n<td>230<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>\u9891\u7387<\/td>\n<td>Hz<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>\u9632\u62a4\u7b49\u7ea7<\/td>\n<td>-<\/td>\n<td>IPX4D<\/td>\n<td>IPX4D<\/td>\n<\/tr>\n<tr>\n<td>\u91c7\u6696\u6c34\u6cf5\u529f\u7387<\/td>\n<td>W<\/td>\n<td>90<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf(\u4e0d\u542b\u5305\u88c5)<\/td>\n<td>kg<\/td>\n<td>28<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>\u5c3a\u5bf8(\u9ad8x\u5bbdx\u539a)<\/td>\n<td>mm<\/td>\n<td>700x400x290<\/td>\n<td>700x400x290<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"kzxt\" class=\"wp-block-heading\">\u56db\u3001\u63a7\u5236\u7cfb\u7edf<\/h2>\n<h3 class=\"wp-block-heading\">OR\u7cfb\u5217\u58c1\u6302\u7089\u6e29\u63a7\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u5177\u6709 OpenTherm BUS (OT) \u901a\u8baf\u534f\u8bae\u7684\u535a\u4e16\u58c1\u6302\u7089\uff0c\u5982G7100\u3001G6300\u3001G6100\u3001G5100\u7b49\u3002<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u5668\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u8981\u529f\u80fd<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>OR60\u58c1\u6302\u7ebf\u63a7\u5236\u5668<\/strong><\/td>\n<td>\u53ef\u76f4\u63a5\u64cd\u63a7\u58c1\u6302\u7089\uff1b\u6807\u51c686mm\u5b89\u88c5\u5c3a\u5bf8\uff1b\u5730\u6696\u548c\u6696\u6c14\u7247\u91c7\u6696\u7cfb\u7edf\u5747\u53ef\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td><strong>OR90\u91c7\u6696\u63a7\u5236\u5668<\/strong><\/td>\n<td>\u53ef\u901a\u8fc7\u611f\u77e5\u5ba4\u5185\u6e29\u5ea6\u63a7\u5236\u58c1\u6302\u7089\u542f\u505c\uff1b\u53ef\u884c\u6a21\u5f0f\u7f16\u7a0b\uff1b\u5730\u6696\u548c\u6696\u6c14\u7247\u7cfb\u7edf\u5747\u53ef\u5e94\u7528<\/td>\n<\/tr>\n<tr>\n<td><strong>OR30 RF\u65e0\u7ebf\u6e29\u63a7\u5668<\/strong><\/td>\n<td>\u8bbe\u7f6e\u623f\u95f4\u6e29\u5ea6\uff1b\u8bbe\u7f6e\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\uff1b\u6709\u7ebf\u5b89\u88c5\u8005\u8005\u65e0\u7ebf\u5b89\u88c5\uff1b\u6545\u969c\u4ee3\u7801\u663e\u793a\u53ca\u590d\u4f4d\u529f\u80fd<\/td>\n<\/tr>\n<tr>\n<td><strong>OR80 RF\u65e0\u7ebf\u6e29\u63a7\u5668<\/strong><\/td>\n<td>\u8bbe\u7f6e\u623f\u95f4\u6e29\u5ea6\uff1b\u8bbe\u7f6e\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u6e29\u5ea6\uff1b\u5f3a\u5927\u7684\u7f16\u7a0b\u529f\u80fd\uff1b\u6709\u7ebf\u5b89\u88c5\u6216\u8005\u65e0\u7ebf\u5b89\u88c5\uff1b\u6545\u969c\u4ee3\u7801\u663e\u793a\u53ca\u590d\u4f4d\u529f\u80fd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u65e0\u7ebf\u63a5\u6536\u5668<\/strong><\/td>\n<td>\u4ec5\u7528\u4e8e\u65e0\u7ebf\u6e29\u63a7\u5668 OR30 RF \/ OR80 RF<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">MR50\u623f\u95f4\u6e29\u63a7\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u4e3b\u8981\u7528\u4e8e\u5bb6\u5ead\u5730\u6696\u7cfb\u7edf\uff0c\u80fd\u591f\u63a7\u5236\u7535\u70ed\u6267\u884c\u5668\uff0c\u63d0\u4f9b\u5206\u533a\u63a7\u6e29\u529f\u80fd\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u8bbe\u7f6e\u5e76\u663e\u793a\u623f\u95f4\u6e29\u5ea6<\/li>\n<li>\u7f16\u8f91\u529f\u80fd<\/li>\n<li>\u9632\u51bb\u4fdd\u62a4\u529f\u80fd<\/li>\n<li>\u5927LCD\u5c4f\uff0c\u4e00\u4f53\u5316\u5f27\u5f62\u8868\u9762\u8bbe\u8ba1\uff0c\u7b80\u6d01\u6d41\u7545<\/li>\n<li>\u9ad8\u8010\u5019\u6027\uff0c\u66f4\u52a0\u5b89\u5168\uff0c\u8010\u5019\u6027\u5f3a<\/li>\n<li>\u5b89\u88c5\u7b80\u5355\uff0c\u64cd\u4f5c\u4fbf\u6377<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">CR10\u58c1\u6302\u7089\u6e29\u63a7\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u5177\u6709 OpenTherm (OT) \u6216\u7740 EMS BUS \u901a\u8baf\u534f\u8bae\u7684\u535a\u4e16\u58c1\u6302\u7089\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u6b27\u6d32\u539f\u88c5\u8fdb\u53e3\uff0c\u73b0\u4ee3\u5de5\u4e1a\u8bbe\u8ba1<\/li>\n<li>\u8bbe\u7f6e\u5e76\u663e\u793a\u623f\u95f4\u6e29\u5ea6<\/li>\n<li>\u53ef\u4e0e MZ100 \u63a7\u5236\u6a21\u5757\u7ed3\u5408\u4f7f\u7528\u8fdb\u884c\u533a\u57df\u6e29\u5ea6\u63a7\u5236<\/li>\n<li>\u53ef\u4e0e CW400 \u7ed3\u5408\u4f5c\u4e3a\u8fdc\u7a0b\u6e29\u5ea6\u4f20\u611f\u5668<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">CW400\u6c14\u5019\u8865\u507f\u578b\u7cfb\u7edf\u63a7\u5236\u5668<\/h3>\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u5177\u6709 EMS BUS \u901a\u8baf\u534f\u8bae\u7684\u535a\u4e16\u58c1\u6302\u7089\u3002<\/p>\n<ul class=\"wp-block-list\">\n<li>\u7528\u4e8e\u590d\u6742\u91c7\u6696\u7cfb\u7edf\u7684\u7cfb\u7edf\u6e29\u63a7\u5668<\/li>\n<li>\u6c14\u5019\u8865\u507f\u7cfb\u7edf\u63a7\u5236\uff0c\u542b\u5ba4\u5916\u6e29\u5ea6\u4f20\u611f\u5668\uff0c\u65e0\u9700\u8fdc\u7a0b\u63a7\u5236\u5373\u53ef\u63a7\u5236\u6700\u591a4\u4e2a\u91c7\u6696\u56de\u8def<\/li>\n<li>\u53ef\u7528\u4f5c\u623f\u95f4\u6e29\u63a7\u5668\uff0c\u96c6\u6210\u4e86\u623f\u95f4\u6e29\u5ea6\u4f20\u611f\u5668<\/li>\n<li>\u592a\u9633\u80fd\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34<\/li>\n<li>\u6bcf\u4e2a\u91c7\u6696\u56de\u8def\u67092\u4e2a\u65f6\u95f4\u7f16\u7a0b<\/li>\n<li>\u91c7\u6696\u6bcf\u5468\u65f6\u949f\u7f16\u7a0b\uff0c\u6bcf\u59296\u4e2a\u5207\u6362\u70b9<\/li>\n<li>\u6bcf\u4e2a\u751f\u6d3b\u70ed\u6c34\u56de\u8def\u6709\u65f6\u949f\u7a0b\u5e8f<\/li>\n<li>\u89e6\u6478\u6309\u952e<\/li>\n<li>\u9ad8\u5206\u8fa8\u7387\u7684\u6db2\u6676\u663e\u793a\u5c4f\uff0c\u4f18\u8d8a\u7684\u64cd\u4f5c\u4f7f\u7528\u6027<\/li>\n<li>\u6e29\u5ea6\u6d41\u91cf\u8c03\u8282\u63a7\u5236\uff08\u51cf\u5c11\u6cf5\u8fd0\u884c\u65f6\u95f4\u7684\u529f\u7387\u63a7\u5236\uff0c\u4f18\u5316\u6cf5\u8fd0\u884c\u65f6\u95f4\u7684\u6d41\u91cf\u91cf\u63a7\u5236\uff09<\/li>\n<li>\u81ea\u52a8\u6e05\u6d01\u6e05\uff0c\u6bcf\u65e5\u53ef\u7f16\u7a0b<\/li>\n<li>\u5185\u7f6e\u5927\u91cf\u670d\u52a1\u5668\u529f\u80fd\uff0c\u4f8b\u5982\u6df7\u5408\u6cf5\u3001\u9600\u95e8\u7b49\u7684\u8bbe\u7f6e\u548c\u529f\u80fd\u6d4b\u8bd5\u7b49<\/li>\n<li>\u5728\u7b80\u5355\u7684\u83dc\u5355\u66f2\u7ebf\u548c\u8be6\u7ec6\u7684\u91c7\u6696\u66f2\u7ebf\u4e4b\u95f4\u8fdb\u884c\u8fde\u63a5\u4e3a\u5ba2\u6237\u63d0\u4f9b\u7cfb\u7edf\u4fe1\u606f\u7684\u529f\u80fd\uff08\u5404\u6e29\u5ea6\u3001\u7ec4\u4ef6\u7684\u8fd0\u884c\u72b6\u6001\u7b49\uff09<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u533a\u57df\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MZ100<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u53ef\u901a\u8fc7\u63a7\u5236\u6c34\u6cf5\u3001\u9600\u95e8\u3001\u6e29\u5ea6\u4f20\u611f\u5668\u5b9e\u73b0\u533a\u57df\u6e29\u5ea6\u63a7\u5236<\/li>\n<li>\u4e0eCR10\u7ed3\u5408\u4f7f\u7528\uff0c\u6700\u591a\u63a7\u52363\u4e2a\u672a\u6df7\u5408\u7684\u91c7\u6696\u56de\u8def<\/li>\n<li>\u5728\u4e00\u4e2a\u7cfb\u7edf\u4e2d\u6700\u591a\u53ef\u4ee5\u67093\u4e2aMZ100\u63a7\u5236\u5668\u6a21\u5757<\/li>\n<li>\u9002\u7528\u4e8e\u8282\u80fd\u8868<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6c34\u8def\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MM100<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u53ef\u63a7\u52361\u4e2a\u4f9b\u70ed\u56de\u8def\u7528\u4e8e\u5728\u6df7\u6c34\u7cfb\u7edf\u6216\u975e\u6df7\u6c34\u7cfb\u7edf\u4e2d\u63a7\u5236\/\u5173\u9600\u95e8<\/li>\n<li>\u4e5f\u53ef\u63a7\u5236\"\u4e8c\u6b21\u56de\u8def\"\u4e4b\u540e\u7684\u6c34\u7bb1\/\u7f13\u51b2\u7f38<\/li>\n<li>1\u4e2a\u91c7\u6696\u56de\u8def\u7684\u6c34\u529b\u5faa\u73af<\/li>\n<li>1\u4e2a\u91c7\u6696\u56de\u8def\u6216\u53ef\u56de\u8def\u7684\u6df7\u5408\u5668\u6253\u5f00\/\u5173\u9600<\/li>\n<li>\u5982\u679c\u751f\u6d3b\u70ed\u6c34\u6c34\u529b\u5faa\u73af\u30011\u4e2a\u5faa\u73af\u6c34\u6cf5<\/li>\n<li>\u53bb\u8026\u4f20\u8f93\u5668\u548c\u6d41\u91cf\u6e29\u5ea6\u4f20\u611f\u5668<\/li>\n<li>\u53ef\u7528\u4e8e\u9ad8\u6548<\/li>\n<li>\u96c6\u6210\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u53bb\u8026\u5408<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u592a\u9633\u80fd\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MS100<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u63a7\u5236\u592a\u9633\u80fd\u96c6\u70ed\u52a0\u70ed\u4ee5\u53ca\u592a\u9633\u80fd\u8f85\u52a9\u91c7\u6696<\/li>\n<li>\u592a\u9633\u80fd\u548c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u8054\u52a8\u7cfb\u7edf\uff0c\u771f\u6b63\u6210\u4e3a\u4f1a\u601d\u8003\u7684\u91c7\u6696\u63a7\u5236\u4e2d\u5fc3<\/li>\n<li>\u5e26\u6765\u667a\u6167\u8282\u80fd\u7684\u7efc\u5408\u4eab\u53d7<\/li>\n<li>\u592a\u9633\u80fd\u751f\u6d3b\u70ed\u6c34\u548c\u592a\u9633\u80fd\u4f18\u5316\u529f\u80fd<\/li>\n<li>\u652f\u6301\u9ad8\u6548\u6cf5<\/li>\n<li>\u5e26\u5206\u79bb\u70ed\u4ea4\u6362\u5668\u62162\u4e2a\u4e32\u8054\u6c34\u7bb1\u7684\u592a\u9633\u80fd\u751f\u6d3b\u70ed\u6c34\u6c34\u7bb1<\/li>\n<li>\u70ed\u6d88\u6bd2<\/li>\n<li>\u53cc\u5339\u914d\u6d41\u91cf<\/li>\n<li>\u96c6\u6210\u5728\u592a\u9633\u80fd\u6cf5\u7ad9\u6216\u6c34\u7bb1\u4e2d<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u7ea7\u8054\u6e29\u5ea6\u63a7\u5236\u6a21\u5757 MC400<\/h3>\n<ul class=\"wp-block-list\">\n<li>MC400\u7ea7\u8054\u6a21\u5757\u53ef\u4ee5\u8ba9\u591a\u53f0\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u5e76\u8054\u4f7f\u7528\uff0c\u5bf9\u4e8e\u7cfb\u7edf\u6765\u8bf4\uff0c\u5c31\u5982\u540c\u662f\u5728\u4f7f\u7528\u4e00\u53f0\u5927\u9505\u7089<\/li>\n<li>\u7528\u4e8e\u6700\u591a4\u53f0EMS\u58c1\u6302\u7089\u7ea7\u8054<\/li>\n<li>\u6700\u591a5\u4e2a\u7ea7\u8054\u6a21\u5757\u5728\u7cfb\u7edf\u4e2d\uff0c\u5373\u6700\u591a16\u53f0EMS\u58c1\u6302\u7089<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u667a\u80fd\u63a7\u5236\u7cfb\u7edf<\/h3>\n<p class=\"wp-block-paragraph\"><strong>\u77e5\u4f60\u51b7\u6696 \u667a\u4eab\u968f\u5fc3<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li><strong>MR120i\u91c7\u6696\u63a7\u5236\u5668\u667a\u80fd \/ \u623f\u95f4\u6e29\u63a7\u5668<\/strong>\uff1a\u8212\u9002\u79d1\u6280 \u968f\u5fc3\u81ea\u5728\uff1b\u6052\u6e29\u63a7\u7130 \u7eff\u8272\u7cbe\u7b97\uff1bAI\u4e92\u8054 \u667a\u7f8e\u53cc\u5168<\/li>\n<li><strong>MR100IRF\u667a\u80fd\u65e0\u7ebf\u91c7\u6696\u63a7\u5236\u5668<\/strong>\uff1a\u771f\u65e0\u7ebf(RF+WiFi\u7ec4\u5408\u65b9\u6848\uff0c\u65e0\u7ebf\u673a\u8eab\u5c0f\u5de7\uff0c\u968f\u5fc3\u6446\u653e\u684c\u9762)\uff1b\u968f\u5fc3\u63a7(\u81ea\u7531\u63a7\u5236\u4efb\u623f\u95f4\uff0c\u8d34\u5fc3\u7eff\u8272\u667a\u80fd\u7ba1\u5bb6)\uff1b\u957f\u7eed\u822a(\u5f85\u673a\u65f6\u957f\u8d85\u8fc76\u4e2a\u6708\uff0c\u7eed\u822a\u957f\u6548\u7eed\u822a)<\/li>\n<\/ul>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"rsxt\" class=\"wp-block-heading\">\u4e94\u3001\u70ed\u6c34\u7cfb\u7edf\uff08\u6c34\u7bb1\uff09<\/h2>\n<h3 class=\"wp-block-heading\">\u7cd6\u74f7\u6c34\u7bb1<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u6b27\u6d32\u8bbe\u8ba1\u7406\u5ff5 \u8212\u9002\u70ed\u6c34\u4eab\u53d7<\/strong>\uff1a\u6e90\u81ea\u6b27\u6d32\u7684\u6c34\u7bb1\u7ed3\u6784\u8bbe\u8ba1\u7406\u5ff5\uff0c\u4e25\u683c\u9075\u5b88\u5fb7\u56fd\u5de5\u4e1a\u6807\u51c6DIN4753\u7684\u54c1\u8d28\u8981\u6c42\uff0c\u627f\u538b\u80fd\u529b\u5f3a\uff0c\u9002\u7528\u4e8e\u6c34\u8d28\u7684\u9ad8\u8d28\u91cf\u7cd6\u74f7\u6c34\u7bb1\uff0c\u4fdd\u8bc1\u9ad8\u8212\u9002\u5ea6\u7684\u70ed\u6c34\u9700\u6c42!<\/li>\n<li><strong>\u5fb7\u56fd\u7cbe\u5de5\u5236\u9020 \u94f8\u5c31\u7a33\u5b9a\u53ef\u9760<\/strong>\uff1a\u5fb7\u56fd\u5de5\u827a\u6807\u51c6\uff0c\u7cbe\u5de5\u5236\u9020\u5320\u5fc3\u53ef\u9760\uff1b\u8d85\u8fc7860\u2103\u9ad8\u6e29\u70e7\u7ed3\u91d1\u5c5e\u5185\u80c6\u8868\u9762\u73bb\u7483\u5316\uff1b\u751f\u6210\u91d1\u5c5e\u5c42\u4e0e\u7cd6\u74f7\u7684\u7ed3\u5408\u4f53\uff0c\u675c\u7edd\u6f0f\u6c14\u3001\u6c7d\u6ce1\u3001\u7126\u70b9\u7b49\u7f3a\u9677\uff1b\u5185\u80c6\u3001\u76d8\u7ba1\u548c\u4e0b\u5c01\u5934\u90fd\u642a\u5851\u540e\u6574\u4f53\u55b7\u5851\uff0c\u6240\u6709\u9600\u5747\u5747\u88ab\u642a\u74f7\u8986\u76d6\uff1b\u4e0a\u4e0b\u5c01\u5934\u91c7\u7528\u53cc\u53e3\u5f0f\u7ed3\u6784\uff0c\u73af\u7f1d\u642a\u74f7\uff1b\u7f37\u7aef\u4e4b\u5904\u88c5\u68c9\u4f9d\u7136\u8fde\u7eed\u5b8c\u6574<\/li>\n<li><strong>\u6709\u6548\u6291\u83cc\u9632\u8150 \u5b88\u62a4\u5bb6\u4eba\u5065\u5eb7<\/strong>\uff1a33mm\u5927\u76f4\u5f84\u65e0\u94c5\u9541\u68d2(\u727a\u7272\u6781\u4fdd\u62a4)\u5bf9\u642a\u74f7\u5185\u80c6\u8fdb\u884c\u4fdd\u62a4\uff0c\u786e\u4fdd\u6c34\u7bb1\u957f\u671f\u4f7f\u7528\u4e0d\u88ab\u8150\u8680\uff1b\u642a\u74f7\u91c9\u5c42\uff0c\u6709\u6548\u6291\u83cc<\/li>\n<li><strong>\u9ad8\u6548\u4fdd\u6e29\u79d1\u6280 \u517c\u987e\u8282\u80fd\u8212\u9002<\/strong>\uff1a\u53d1\u6ce1\u5c42\u4fdd\u6e29\u91c7\u7528\u5c01\u95ed\u5f0f\u9ad8\u538b\u53d1\u6ce1\uff0c\u73af\u4fdd\u65e0\u6c1f\u805a\u6c28\u916f\u53d1\u6ce1\uff1b\u5bc6\u5ea6\u9ad8\u8fbe40g\/cm\u00b3\uff0c\u70ed\u635f\u5931\u4f4e\u4e8e\u56fd\u6807\u8981\u6c4237%<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u6b27\u5f0f\u8212\u9002\u7cfb\u5217<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6c34\u7bb1\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST150-150EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST200-200EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST300-300EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST300-350EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST300-350EC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5185\u8154\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u9053\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u539a\u5ea6<\/td>\n<td>mm<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u9ad8\u5ea6<\/td>\n<td>mm<\/td>\n<td>985<\/td>\n<td>1248<\/td>\n<td>1713<\/td>\n<td>1248<\/td>\n<td>1713<\/td>\n<\/tr>\n<tr>\n<td>\u66f4\u6362\u9541\u68d2\u6240\u9700\u7684<\/td>\n<td>mm<\/td>\n<td>1400<\/td>\n<td>1700<\/td>\n<td>2100<\/td>\n<td>1700<\/td>\n<td>2100<\/td>\n<\/tr>\n<tr>\n<td><strong>\u50a8\u7f50\u91cf(\u603b\u8ba1)<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u50a8\u91cf\u6e29\u5ea6<\/td>\n<td>L<\/td>\n<td>150<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u91cf\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u635f\u8017\u6027\u80fd*<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u635f\u8017\u70ed\u6c34\u6e29\u5ea6<\/td>\n<td>W\/\u33a1K<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>11<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u7ba1\u7ba1\u5185\u70ed\u6c34\u6700\u9ad8\u6e29\u5ea6<\/td>\n<td>\u2103<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u7ba1\u7ba1\u5185\u70ed\u6c34\u6700\u5927\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">*\u70ed\u635f\u8017\u6570\u503c\u7b26\u5408 GB\/T 28745 \u6807\u51c6<\/p>\n<\/blockquote>\n<h3 class=\"wp-block-heading\">\u7ecf\u5178\u65f6\u5c1a\u7cfb\u5217<\/h3>\n<ul class=\"wp-block-list\">\n<li>\u91d1\u5c5e\u5916\u58f3\uff0c\u8010\u8150\u8680\uff0c\u6297\u7d2b\u5916\u7ebf\uff0c\u53ef\u878d\u5408\u591a\u79cd\u5bb6\u5ead\u88c5\u4fee\u98ce\u683c<\/li>\n<li>\u5236\u5f0f\u591a\u6837\uff0c\u53ef\u4e0e\u592a\u9633\u80fd\u3001\u9505\u7089\u3001\u70ed\u6cf5\u8fdb\u884c\u591a\u80fd\u6e90\u7cfb\u7edf\u7ec4\u5408<\/li>\n<li>120-200L \u4e0a\u51fa\u6c34\u5355\u76d8\u7ba1<\/li>\n<li>150-300L \u4fa7\u51fa\u6c34\u5355\u76d8\u7ba1<\/li>\n<li>200-300L \u4fa7\u51fa\u6c34\u53cc\u76d8\u7ba1<\/li>\n<li>400\/500L \u51fa\u6c34\u7ba1\/\u53cc\u76d8\u7ba1<\/li>\n<\/ul>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u6c34\u7bb1\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST150-500EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST200-500EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST300-400EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST400-600EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST400-650EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST500-500EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST500-600EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST500-750EC<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">WST500-800EC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5185\u8154\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>650<\/td>\n<td>650<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u9053\u76f4\u5f84<\/td>\n<td>mm<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>750<\/td>\n<td>750<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<td>580<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u539a\u5ea6<\/td>\n<td>mm<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>70<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>\u603b\u9ad8\u5ea6<\/td>\n<td>mm<\/td>\n<td>985<\/td>\n<td>1248<\/td>\n<td>1713<\/td>\n<td>1665<\/td>\n<td>1860<\/td>\n<td>1248<\/td>\n<td>1713<\/td>\n<td>852<\/td>\n<td>1270<\/td>\n<\/tr>\n<tr>\n<td>\u66f4\u6362\u9541\u68d2\u6240\u9700\u7684<\/td>\n<td>mm<\/td>\n<td>1400<\/td>\n<td>1700<\/td>\n<td>2300<\/td>\n<td>2400<\/td>\n<td>2400<\/td>\n<td>1700<\/td>\n<td>2100<\/td>\n<td>1340<\/td>\n<td>1860<\/td>\n<\/tr>\n<tr>\n<td><strong>\u50a8\u7f50\u91cf(\u603b\u8ba1)<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u50a8\u91cf\u6e29\u5ea6<\/td>\n<td>L<\/td>\n<td>150<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<td>400<\/td>\n<td>500<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<td>120<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u91cf\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u6c34\u91cf\u6700\u5927\u5de5\u4f5c\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>\u70ed\u635f\u8017\u6027\u80fd*<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u635f\u8017\u70ed\u6c34\u6e29\u5ea6<\/td>\n<td>W\/\u33a1K<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>13<\/td>\n<td>18<\/td>\n<td>18<\/td>\n<td>11<\/td>\n<td>11<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u7ba1\u7ba1\u5185\u70ed\u6c34\u6700\u9ad8\u6e29\u5ea6<\/td>\n<td>\u2103<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<\/tr>\n<tr>\n<td>\u70ed\u7ba1\u7ba1\u5185\u70ed\u6c34\u6700\u5927\u538b\u529b<\/td>\n<td>bar<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">*\u70ed\u635f\u8017\u6570\u503c\u7b26\u5408 GB\/T 28745 \u6807\u51c6<\/p>\n<\/blockquote>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"gsxxysjx\" class=\"wp-block-heading\">\u516d\u3001\u516c\u53f8\u4fe1\u606f\u4e0e\u65f6\u95f4\u7ebf<\/h2>\n<h3 class=\"wp-block-heading\">\u516c\u53f8\u8054\u7cfb\u65b9\u5f0f<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u535a\u4e16\u70ed\u529b\u6280\u672f\uff08\u5317\u4eac\uff09\u6709\u9650\u516c\u53f8<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u5730\u5740\uff1a\u5317\u4eac\u7ecf\u6d4e\u6280\u672f\u5f00\u53d1\u533a\u6c38\u660c\u5357\u8def6\u53f71\u53f7\u697c3\u5c42<\/li>\n<li>\u90ae\u7f16\uff1a100176<\/li>\n<li>\u7535\u8bdd\uff1a400 820 6017<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u535a\u4e16\u70ed\u529b\u6280\u672f\uff08\u4e0a\u6d77\uff09\u6709\u9650\u516c\u53f8<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u5730\u5740\uff1a\u4e0a\u6d77\u5e02\u5609\u5b9a\u533a\u9a6c\u9646\u9547\u4e30\u767b\u8def388\u53f7<\/li>\n<li>\u90ae\u7f16\uff1a201801<\/li>\n<li>\u7535\u8bdd\uff1a400 820 6017<\/li>\n<\/ul>\n<\/li>\n<li>\u4e2d\u5e7f\u544a\u6cd5:20090893\u53f7<\/li>\n<li>\u5168\u56fd\u552e\u540e\u670d\u52a1\u70ed\u7ebf:&nbsp;<strong>400 820 6017<\/strong><\/li>\n<li>Printed in Sep. 2024 \/ 2024\u5e7409\u6708\u5370\u5237<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">\u535a\u4e16\u53d1\u5c55\u65f6\u95f4\u7ebf<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u4efd<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u91cc\u7a0b\u7891\u4e8b\u4ef6<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1731<\/td>\n<td>\u4e1c\u65af\u5fb7\u5c14\u521b\u7acb<\/td>\n<\/tr>\n<tr>\n<td>1894<\/td>\n<td>\u53d1\u660e\u51fa\u4f4e\u538b\u7535\u78c1\u5f0f\u5438\u5c18\u5e76\u83b7\u53d6\u4e13\u5229\uff0c\u6b63\u5f0f\u5ba3\u544a\u7814\u53d1\u6280\u672f<\/td>\n<\/tr>\n<tr>\n<td>1896<\/td>\n<td>\u7f57\u4f2f\u7279\u00b7\u535a\u4e16\u521b\u7acb\uff0c\u63a8\u51fa\u9996\u6b3e\u71c3\u6c14\u70ed\u6c34\u5668\u8bbe\u5907<\/td>\n<\/tr>\n<tr>\n<td>1962<\/td>\n<td>\u535a\u4e16\u9996\u53f0Combi boiler\u9762\u5e02<\/td>\n<\/tr>\n<tr>\n<td>1976<\/td>\n<td>\"Tritherm house\" \u5728\u5fb7\u56fd\u53d6\u5f97\u5236\u9020\u4f7f\u7528\u5927\u578b\u592a\u9633\u80fd\u70ed\u80fd\u7cfb\u7edf\u8d28\uff0c\u8f6c\u5316\u80fd\u6e90\u5229\u7528\u7387\u8fd190%<\/td>\n<\/tr>\n<tr>\n<td>1970<\/td>\n<td>\u5f00\u59cb\u5236\u9020\u5730\u6696<\/td>\n<\/tr>\n<tr>\n<td>1972<\/td>\n<td>\u535a\u4e16\u9996\u6b21\u63a8\u51fa\u70ed\u5f0f\u7a7a\u8c03\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>1986<\/td>\n<td>\u535a\u4e16\u9996\u6b21\u51fa\u53e3\u4e2d\u56fd<\/td>\n<\/tr>\n<tr>\n<td>1997<\/td>\n<td>\u9996\u4e2a\u9879\u76ee\u8fdb\u5165\u4e2d\u56fd<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>\u535a\u4e16\u70ed\u529b\u6280\u672f\u6b63\u5f0f\u8fdb\u5165\u4e2d\u56fd\u5e02\u573a<\/td>\n<\/tr>\n<tr>\n<td>2005<\/td>\n<td>\u5f00\u59cb\u5728\u4e2d\u56fd\u5efa\u7acb\u6280\u672f\u5de5\u5382\uff0c\u751f\u4ea7\u9996\u6279\"\u70ed\u00b7\u6c90\u4eab\u8005\"\u4ea7\u54c1<\/td>\n<\/tr>\n<tr>\n<td>2011<\/td>\n<td>\u535a\u4e16\u9996\u4e2a\u80fd\u6e90\u81ea\u5efa\u5730\u6696\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>2015<\/td>\n<td>\u535a\u4e16\u9996\u5bb6\u5b8c\u5168\u5b89\u5168ENWA\u8ba4\u8bc1\u7684\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u53ca\u70ed\u6c34\u50a8\u4ea7\u54c1<\/td>\n<\/tr>\n<tr>\n<td>2020<\/td>\n<td>\u6b27\u6d32\u4e4b\u661f10\u5468\u5e74\u8363\u8000\u4e0a\u5e02<\/td>\n<\/tr>\n<tr>\n<td>2021<\/td>\n<td>\u535a\u4e16\u65b0\u4e00\u4ee3\u65d7\u8230\u4ea7\u54c1G7100W\u9686\u91cd\u4e0a\u5e02\uff1b\u535a\u4e16\u70ed\u529b\u6280\u672f\u56fd\u5185\u9996\u90e8\u57fa\u5730\u843d\u6210\u542f\u7528<\/td>\n<\/tr>\n<tr>\n<td>2023<\/td>\n<td>\u535a\u4e16G8550i W\u5168\u6c14\u5019\uff1b\u535a\u4e16\u65b0G6300AW\/W\u7cfb\u5217\u6b63\u5f0f\u4e0a\u5e02<\/td>\n<\/tr>\n<tr>\n<td>2024<\/td>\n<td>\u535a\u4e16\u65b0\u88c5\u8fdb\u53e3\uff1b\u535a\u4e16G8550i W\u5168\u6c14\u5019\uff1b\u535a\u4e16\u65b0G6300AW\/W\u7cfb\u5217\u6b63\u5f0f\u4e0a\u5e02<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 class=\"wp-block-heading\">\u9644\u5f55\uff1a\u4ea7\u54c1\u7cfb\u5217\u603b\u89c8<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u5217<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u4f4d<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u7279\u5f81<\/th>\n<th class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u5730<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Condens 9000i WM<\/strong><\/td>\n<td>GC 9000i WM<\/td>\n<td>\u65d7\u8230\u96c6\u6210\u51b7\u51dd\u7089<\/td>\n<td>150L\u5206\u5c42\u6c34\u7bb1\uff0cCMS\u71c3\u70e7\u7ba1\u7406\uff0c\u5fb7\u56fd\u539f\u88c5\u8fdb\u53e3<\/td>\n<td>\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td><strong>Condens 8700i W<\/strong><\/td>\n<td>GC 8700i WM (24\/35kW)<\/td>\n<td>\u51b7\u51dd\u5f0f\u91c7\u6696\u70ed\u6c34\u7089<\/td>\n<td>22L\u5347\u4f4d\uff0c\u6c22\u80fd\u5c31\u7eea\uff0c50\u4f59\u91cd\u5b89\u5168\u4fdd\u62a4<\/td>\n<td>\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td><strong>Condens 7100 W<\/strong><\/td>\n<td>OC 7100W (24-39kW)<\/td>\n<td>\u5de5\u4e1a4.0\u5236\u9020<\/td>\n<td>\u5168\u7403\u9500\u91cf\u8d85160\u4e07\uff0c\u516b\u5927\u6838\u5fc3\u6280\u672f<\/td>\n<td>\u5fb7\u56fd\u97e6\u5c14\u7459<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6b27\u6d32\u8d35\u65cf<\/strong><\/td>\n<td>DNZ\u7cfb\u5217 (25\/35kW)<\/td>\n<td>\u51b7\u51dd\u5f0f\u6696\u6d74\u4e24\u7528<\/td>\n<td>\u84dd\u7ed2\u7130\uff0cCHG\u6c34\u529b\u5347\u7ea7\uff0c\u6b27\u6d32\u4e09\u661f\u8ba4\u8bc1<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G8550i W<\/strong><\/td>\n<td>G8550i W (24kW)<\/td>\n<td>\u5fb7\u539f\u88c5\u8fdb\u53e3<\/td>\n<td>\u7b2c4\u4ee3\u70ed\u80fd\u82afEMS2.0\uff0c\u5168\u6c14\u5019\u6052\u6e29<\/td>\n<td>\u5fb7\u56fd<\/td>\n<\/tr>\n<tr>\n<td><strong>\u6b27\u6d32\u4e4b\u661f\u5c0a\u4eab\u7248<\/strong><\/td>\n<td>ZWC\u7cfb\u5217 (24\/28\/35kW)<\/td>\n<td>\u7ecf\u5178\u54c1\u8d28<\/td>\n<td>93%\u70ed\u6548\u7387\uff0c10\u9879\u5b89\u5168\u4fdd\u62a4\uff0c100\u4e07+\u9500\u91cf<\/td>\n<td>\u6b27\u6d32<\/td>\n<\/tr>\n<tr>\n<td><strong>G7\u955c\u9762\u7248<\/strong><\/td>\n<td>G7200W (24\/28kW)<\/td>\n<td>\u5149\u5f71\u73bb\u7483\u9762\u677f<\/td>\n<td>\u4e00\u7ea7\u9759\u97f3\uff0cWiFi\u64cd\u63a7\uff0c\u4e13\u5229\u6392\u70df<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>G6300W<\/strong><\/td>\n<td>G6300W (18\/22kW)<\/td>\n<td>\u7ecf\u6d4e\u5b9e\u7528<\/td>\n<td>48dB(A)\u4f4e\u566a\uff0c\u6781\u7aef\u73af\u5883\u901a\u7528<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5de5\u4e1a\u94a2\u7089<\/strong><\/td>\n<td>-<\/td>\n<td>\u5de5\u4e1a\u7ea7<\/td>\n<td>\u5927\u529f\u7387\u5546\u7528\/\u5de5\u7a0b<\/td>\n<td>-<\/td>\n<\/tr>\n<tr>\n<td><strong>\u65b0\u98ce<\/strong><\/td>\n<td>\u5bb6\u7528\u65b0\u98ce\u673a\u6298\u9875<\/td>\n<td>\u65b0\u98ce\u51c0\u5316<\/td>\n<td>-<\/td>\n<td>-<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<h2 id=\"cptj\" class=\"wp-block-heading\">\u4e03\u3001\u535a\u4e16\u58c1\u6302\u7089\u4ea7\u54c1\u56fe\u9274<\/h2>\n<div class=\"lm-sup\">\n<style>\n.lm-sup{max-width:900px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#2c3e3e;line-height:1.7;}\n.lm-sup h2{font-size:21px;color:#12314F;margin:26px 0 12px;border-left:5px solid #E8541E;padding-left:12px;}\n.lm-sup h3{font-size:16px;color:#1f4d45;margin:14px 0 8px;}\n.lm-sup .lm-sup-gallery{display:grid;grid-template-columns:repeat(auto-fill,minmax(150px,1fr));gap:12px;margin:14px 0;}\n.lm-sup .lm-sup-gallery figure{margin:0;background:#fff;border:1px solid #e2e8e6;border-radius:10px;overflow:hidden;}\n.lm-sup .lm-sup-gallery img{width:100%;height:auto;display:block;}\n.lm-sup .lm-sup-gallery figcaption{font-size:12.5px;color:#475569;padding:8px 10px;}\n.lm-sup .lm-sup-note{background:#fffbeb;border:1px solid #fde68a;border-radius:10px;padding:10px 14px;margin:12px 0;font-size:13px;color:#92400e;}\n.lm-sup table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px;background:#fff;}\n.lm-sup th,.lm-sup td{border:1px solid #d8e3e0;padding:9px 11px;text-align:left;}\n.lm-sup th{background:#12314F;color:#fff;font-weight:600;}\n.lm-sup tr:nth-child(even) td{background:#f5f9f8;}\n.lm-sup .inq{background:#fff7ed;border:1px solid #fdba74;border-left:5px solid #E8541E;border-radius:10px;padding:12px 16px;margin:14px 0;color:#7c2d12;font-size:14.5px;}\n.lm-sup .inq strong{color:#c2410c;}\n.lm-sup .inq a{color:#c2410c;border-bottom:1px solid #fdba74;font-weight:700;}\n.lm-sup .lm-sup-links{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:14px 0;}\n.lm-sup .lm-sup-links a{display:block;background:#fff;border:1px solid #d8e3e0;border-radius:10px;padding:12px 14px;color:#1f4d45;text-decoration:none;font-weight:600;font-size:14px;transition:.2s;}\n.lm-sup .lm-sup-links a:hover{border-color:#E8541E;box-shadow:0 2px 10px rgba(232,84,30,.12);}\n.lm-sup .lm-sup-links a span{display:block;font-weight:400;font-size:12px;color:#647b76;margin-top:3px;}\n.lm-sup details{border:1px solid #d8e3e0;background:#fff;border-radius:10px;padding:0 14px;margin:8px 0;}\n.lm-sup summary{cursor:pointer;padding:12px 0;font-weight:600;color:#1f4d45;}\n.lm-sup details p{padding:0 0 12px;color:#475569;}\n.lm-sup .lm-sup-store{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0;}\n.lm-sup .lm-sup-store .st{background:#fff;border:1px solid #e2e8e6;border-radius:12px;padding:14px;}\n.lm-sup .lm-sup-store .st h4{margin:0 0 8px;color:#12314F;}\n.lm-sup .lm-sup-store .mgr{font-size:14px;color:#475569;margin:5px 0;}\n.lm-sup .lm-sup-store .mgr a{color:#1d4ed8;border-bottom:1px solid #c7d2fe;font-weight:700;}\n.lm-sup .lm-sup-store .hotline{display:inline-block;margin:8px 0 4px;font-size:18px;font-weight:800;color:#E8541E;background:#fff;border:2px solid #E8541E;border-radius:8px;padding:6px 14px;}\n.lm-sup .lm-sup-store .hotline a{color:#E8541E;border-bottom:none;}\n.lm-sup .lm-sup-store .nav{margin:7px 0 2px;font-size:13.5px;}\n.lm-sup .lm-sup-store .nav a{color:#1d4ed8;border-bottom:1px solid #c7d2fe;font-weight:700;}\n<\/style>\n<h2>\u535a\u4e16\u58c1\u6302\u7089 \u00b7 \u4ea7\u54c1\u56fe\u9274<\/h2>\n<div class=\"lm-sup-gallery\">\n<figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg\" alt=\"\u535a\u4e16 \u51b7\u51dd\u7089 Condens 3260W\"><figcaption>\u51b7\u51dd\u7089 Condens 3260W<\/figcaption><\/figure>\n<figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-cgl-G6100W.jpg\" alt=\"\u535a\u4e16 \u5e38\u89c4\u7089 G6100W\"><figcaption>\u5e38\u89c4\u7089 G6100W<\/figcaption><\/figure>\n<figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-cgl-G7100W.jpg\" alt=\"\u535a\u4e16 \u5e38\u89c4\u7089 G7100W\"><figcaption>\u5e38\u89c4\u7089 G7100W<\/figcaption><\/figure>\n<figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-cgl-G6zgPlus.jpg\" alt=\"\u535a\u4e16 \u5e38\u89c4\u7089 G6 \u8ffd\u5149 Plus\"><figcaption>\u5e38\u89c4\u7089 G6 \u8ffd\u5149 Plus<\/figcaption><\/figure>\n<\/div>\n<h2>\u535a\u4e16\u58c1\u6302\u7089 \u00b7 \u53c2\u8003\u4ef7\u683c\uff08\u9f99\u8109\u4e3b\u63a8\u578b\u53f7\uff09<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u578b\u53f7<\/th>\n<th>\u529f\u7387<\/th>\n<th>\u7c7b\u578b<\/th>\n<th>\u9f99\u8109\u53c2\u8003\u4ef7\uff082026\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>G6100W<\/td>\n<td>24kW<\/td>\n<td>\u5e38\u89c4\u4e24\u7528\uff08\u6b27\u6d32\u8fdb\u53e3\uff09<\/td>\n<td>\u00a55,850<\/td>\n<\/tr>\n<tr>\n<td>\u6b27\u6d32\u8d35\u65cf DNZ \u7cfb\u5217<\/td>\n<td>25\/30kW<\/td>\n<td>\u51b7\u51dd\u4e24\u7528<\/td>\n<td>\u00a510,500<\/td>\n<\/tr>\n<tr>\n<td>7760iW<\/td>\n<td>35\/40kW<\/td>\n<td>\u51b7\u51dd\uff08\u8fdb\u53e3\uff09<\/td>\n<td>\u00a515,075\u201318,625<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"inq\">\ud83d\udcde <strong>\u4e0a\u8868\u4e3a\u9f99\u8109\u4e3b\u63a8\u535a\u4e16\u578b\u53f7\u53c2\u8003\u4ef7<\/strong>\uff1b\u535a\u4e16\u5168\u7cfb\uff08Condens 9000i\/8700i\/7100i\u3001G8550i\u3001\u6b27\u6d32\u4e4b\u661f\u3001G7 \u955c\u9762\u7248\u3001G7350i Pro\u3001G6300W\u3001C3260W \u7b49\uff09\u6700\u7ec8\u6210\u4ea4\u968f\u914d\u7f6e\u3001\u6d3b\u52a8\u4e0e\u9f99\u8109\u4e13\u5c5e\u4f18\u60e0\u6d6e\u52a8\u3002\u5b8c\u6574\u578b\u53f7\u4ef7\u76ee\u4e0e\u4f18\u60e0\u4ef7\uff0c\u8bf7\u89c1 <a href=\"?page_id=11082\">\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b<\/a>\uff0c\u6216\u62e8\u6253\u95e8\u5e97\u70ed\u7ebf <a href=\"tel:02886131795\">028-86131795<\/a> \/ <a href=\"tel:02865272586\">028-65272586<\/a> \u514d\u8d39\u52d8\u6d4b\u62a5\u4ef7\u3002<\/div>\n<div class=\"lm-sup-note\">\ud83d\udccc <strong>\u4e24\u4e2a\u53eb\u6cd5\u5148\u5206\u6e05\uff1a<\/strong>\u535a\u4e16\u58c1\u6302\u7089\u53ea\u5206\u4e24\u5927\u7c7b\u2014\u2014<strong>\u51b7\u51dd\u7089<\/strong>\uff08\u70ed\u6548\u7387\u7ea6 108%\uff0c\u66f4\u7701\u6c14\uff09\u4e0e<strong>\u5e38\u89c4\u7089<\/strong>\uff08\u70ed\u6548\u7387 93%\uff09\u3002\u5e38\u89c4\u7089\u65e2\u91c7\u6696\u53c8\u4f9b\u751f\u6d3b\u70ed\u6c34\uff0c\u6240\u4ee5\u53c8\u53eb<strong>\u666e\u901a\u7089<\/strong>\uff0c\u4e5f\u53eb<strong>\u4e24\u7528\u7089<\/strong>\uff1b\u53ea\u8d1f\u8d23\u91c7\u6696\u3001\u70ed\u6c34\u53e6\u914d\u70ed\u6c34\u5668\u7684\u53eb\"\u5355\u91c7\u6696\u7089\"\u3002\u65e5\u5e38\u641c\u7d22\u91cc\u7684\u666e\u901a\u7089\u3001\u5e38\u89c4\u7089\u3001\u4e24\u7528\u7089\uff0c\u6307\u7684\u662f\u540c\u4e00\u7c7b\u4ea7\u54c1\uff0c\u672c\u6587\u6309\u5927\u5bb6\u4e60\u60ef\u7684\u53eb\u6cd5\u6df7\u7528\u3002<\/div>\n<h2>\u76f8\u5173\u4e13\u9898\uff08\u5185\u94fe\u5bfc\u822a\uff09<\/h2>\n<h3>\u535a\u4e16\u6210\u90fd\u5b8c\u5de5\u6848\u4f8b\u4e0e\u65b9\u6848<\/h3>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=8505\">\u6ee8\u6c5f\u5929\u6a3e \u00b7 \u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u56db + \u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696<span>\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b<\/span><\/a><br \/>\n  <a href=\"?page_id=11626\">\u5929\u5e9c\u4e16\u5bb6\u4e8c\u671f \u00b7 \u4e00\u62d6\u4e94 + \u535a\u4e16\u51b7\u51dd\u7089 + \u65b0\u98ce<span>\u4e09\u7cfb\u7edf\u5b8c\u5de5\u6848\u4f8b<\/span><\/a><br \/>\n  <a href=\"?page_id=7212\">\u66fe\u5148\u751f 195\u33a1 \u5927\u5e73\u5c42<span>\u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696 + \u65b0\u98ce\u65b9\u6848\u4e66<\/span><\/a><br \/>\n  <a href=\"?page_id=10461\">C\u5973\u58eb \u00b7 \u4e8c\u624b\u623f\u5957\u4e8c<span>\u535a\u4e16 G6100 \u4e24\u7528\u7089 + \u4f1f\u661f\u603b\u63a7<\/span><\/a><br \/>\n  <a href=\"?page_id=10379\">\u5f20\u5973\u58eb \u00b7 \u5b66\u533a\u623f\u5957\u4e8c<span>\u535a\u4e16\u8ffd\u5149 G6100W \u6696\u6c14\u7247<\/span><\/a>\n<\/div>\n<h3>\u535a\u4e16\u673a\u578b\u4f7f\u7528\u4e0e\u7ef4\u4fee\u5b9e\u5f55<\/h3>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=13587\">\u6c34\u6e29\u5ffd\u51b7\u5ffd\u70ed<span>\u4e09\u901a\u9600\u5361\u6ede\u6e05\u7406\u5b9e\u5f55<\/span><\/a><br \/>\n  <a href=\"?page_id=12256\">\u9505\u7089\u62a5\u9519 EA<span>\u672a\u63a2\u6d4b\u5230\u706b\u7130\u6392\u67e5\u5b9e\u5f55<\/span><\/a><br \/>\n  <a href=\"?page_id=13109\">\u58c1\u6302\u7089\u7ef4\u4fee\u4fdd\u517b<span>\u4e0d\u70b9\u706b \u00b7 \u62a5\u9519 \u00b7 \u6f0f\u6c34<\/span><\/a>\n<\/div>\n<h3>\u9009\u578b\u4e0e\u70ed\u6e90\u5bf9\u6bd4<\/h3>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=11074\">\u58c1\u6302\u7089\u600e\u4e48\u9009<span>\u51b7\u51dd\/\u5e38\u89c4 \u00b7 \u529f\u7387 \u00b7 \u54c1\u724c\u6a2a\u8bc4<\/span><\/a><br \/>\n  <a href=\"?page_id=12812\">\u51b7\u51dd\u7089\u548c\u666e\u901a\u7089\u600e\u4e48\u9009<span>\u6548\u7387 \u00b7 \u6210\u672c \u00b7 \u9002\u7528\u8fb9\u754c<\/span><\/a><br \/>\n  <a href=\"?page_id=13489\">\u5355\u91c7\u6696\u7089\u600e\u4e48\u9009<span>\u5730\u6696\u4e0e\u660e\u88c5\u6696\u6c14\u9009\u578b<\/span><\/a><br \/>\n  <a href=\"?page_id=12776\">\u8001\u623f\u660e\u88c5\u6696\u6c14\u600e\u4e48\u9009\u7089<span>\u5c0f\u529f\u7387\u53d8\u9891\u7089<\/span><\/a><br \/>\n  <a href=\"?page_id=3415\">\u5730\u6696\u70ed\u6e90\u6df1\u5ea6\u5bf9\u6bd4<span>\u6c34\u6a21\u5757 vs \u51b7\u51dd\u7089<\/span><\/a><br \/>\n  <a href=\"?page_id=5601\">\u4e8c\u8054\u4f9b vs \u51b7\u51dd\u7089 + \u8282\u80fd\u5730\u6696<span>\u5bf9\u6bd4\u5206\u6790<\/span><\/a><br \/>\n  <a href=\"?page_id=12011\">\u5929\u5e9c\u4e16\u5bb6 \u00b7 \u5929\u6c1f\u5730\u6c34 vs \u5168\u6548 + \u535a\u4e16<span>\u53cc\u65b9\u6848\u5bf9\u6bd4<\/span><\/a><br \/>\n  <a href=\"?page_id=669\">\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf<span>\u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/span><\/a>\n<\/div>\n<h3>\u5176\u4ed6\u54c1\u724c\u540c\u54c1\u7c7b<\/h3>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=1824\"><a href=\"https:\/\/longmai-nt.com\/?page_id=2553\" title=\"\u83f2\u65af\u66fc\u56fd\u4ea7\u51b7\u51dd\u7089\">\u83f2\u65af\u66fc<\/a>\u58c1\u6302\u7089\u8be6\u60c5<span>\u51b7\u51dd\u6280\u672f\u6807\u6746<\/span><\/a><br \/>\n  <a href=\"?page_id=1841\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5<span>\u5c0f\u6237\u578b\u5730\u6696\u4e13\u7528<\/span><\/a><br \/>\n  <a href=\"?page_id=2489\">\u6797\u5185\u58c1\u6302\u7089\u8be6\u60c5<span>\u65e5\u7cfb\u6052\u6e29\u70ed\u6c34<\/span><\/a>\n<\/div>\n<h3>\u4ef7\u683c\u4e0e\u670d\u52a1<\/h3>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=11082\">\u58c1\u6302\u7089\u591a\u5c11\u94b1<span>\u5168\u54c1\u724c\u4ef7\u683c + \u9f99\u8109\u4f18\u60e0\u4ef7<\/span><\/a><br \/>\n  <a href=\"?page_id=10977\">\u5730\u6696\u53c2\u8003\u4ef7\u683c<span>\u5730\u6696\u65b9\u6848<\/span><\/a><br \/>\n  <a href=\"?page_id=10982\">\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c<span>\u660e\u88c5\u5957\u9910<\/span><\/a><br \/>\n  <a href=\"?page_id=10975\">\u4e24\u8054\u4f9b\u53c2\u8003\u4ef7\u683c<span>\u805a\u5408\u9875<\/span><\/a><br \/>\n  <a href=\"?page_id=10970\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4ef7\u683c<span>\u7efc\u5408\u53c2\u8003\u4ef7<\/span><\/a><br \/>\n  <a href=\"?page_id=14057\">\u6696\u901a\u552e\u540e\u670d\u52a1\u4ef7\u683c\u8868<span>\u58c1\u6302\u7089 \u00b7 \u6696\u6c14\u7247 \u00b7 \u5730\u6696\u7ef4\u4fdd<\/span><\/a><br \/>\n  <a href=\"?page_id=625\">\u670d\u52a1\u4fdd\u969c<span>\u627f\u8bfa\u4e0e\u6807\u51c6<\/span><\/a>\n<\/div>\n<p>\u58c1\u6302\u7089\u5728\u70ed\u6c34\u7cfb\u7edf\u91cc\u7684\u89d2\u8272\uff08\u4e24\u7528\u7089\u4e0e\u7cfb\u7edf\u7089 + \u6c34\u7bb1\u600e\u4e48\u9009\u3001\u71c3\u6c14\u8868\u6821\u6838\uff09\uff0c\u89c1 <a href=\"?page_id=1879\">\u5bb6\u7528\u70ed\u6c34\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7<\/a>\u3002<\/p>\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n<details>\n<summary>\u535a\u4e16\u58c1\u6302\u7089\u503c\u5f97\u4e70\u5417\uff1f<\/summary>\n<p>\u535a\u4e16\u6545\u969c\u7387\u4f4e\u3001\u552e\u540e\u7f51\u70b9\u5e7f\u3001\u6027\u4ef7\u6bd4\u7a81\u51fa\uff0c\u51b7\u51dd\u7089\u7ea6 108% \u70ed\u6548\u7387\u3002\u9884\u7b97\u6709\u9650\u9009 G6100W \u5e38\u89c4\uff08\u00a55,850 \u8d77\uff09\uff0c\u8ffd\u6c42\u8282\u80fd\u9009\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\uff08\u00a510,500 \u8d77\uff09\u3002\u8be6\u89c1\u6b63\u6587\u7b2c\u4e09\/\u56db\u7ae0\u3002<\/p>\n<\/details>\n<details>\n<summary>\u535a\u4e16\u51b7\u51dd\u7089\u548c\u83f2\u65af\u66fc\u600e\u4e48\u9009\uff1f<\/summary>\n<p>\u4e24\u8005\u5747\u4e3a\u5fb7\u7cfb\u6807\u6746\uff1a\u83f2\u65af\u66fc\u51b7\u51dd\u6280\u672f\uff08\u5168\u7cfb Inox \u4e0d\u9508\u94a2\u6362\u70ed\u5668\uff09\u66f4\u5f3a\u3001\u64cd\u4f5c\u9762\u677f\u504f\u4e13\u4e1a\uff1b\u535a\u4e16\u552e\u540e\u7f51\u70b9\u66f4\u5e7f\u3001\u6027\u4ef7\u6bd4\u66f4\u9ad8\u3002\u957f\u671f\u81ea\u4f4f\u91cd\u7701\u6c14\u9009\u83f2\u65af\u66fc\uff0c\u91cd\u7701\u5fc3\u552e\u540e\u9009\u535a\u4e16\u3002\u8be6\u89c1 <a href=\"?page_id=11074\">\u300a\u58c1\u6302\u7089\u600e\u4e48\u9009\u300b<\/a> \u56db\u54c1\u724c\u6a2a\u8bc4\u3002<\/p>\n<\/details>\n<details>\n<summary>\u535a\u4e16\u4ef7\u683c\u5305\u542b\u5b89\u88c5\u5417\uff1f<\/summary>\n<p>\u4e0a\u8868\u4e3a\u8bbe\u5907\u53c2\u8003\u4ef7\uff0c\u6700\u7ec8\u6210\u4ea4\u542b\u5b89\u88c5\u914d\u7f6e\u4e0e\u9f99\u8109\u4f18\u60e0\u4ef7\uff0c\u8bf7\u89c1 <a href=\"?page_id=11082\">\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b<\/a> \u6216\u81f4\u7535\u95e8\u5e97\u514d\u8d39\u52d8\u6d4b\u62a5\u4ef7\u3002<\/p>\n<\/details>\n<h2>\u95e8\u5e97\u54a8\u8be2 \u00b7 \u9500\u552e\u7535\u8bdd<\/h2>\n<div class=\"lm-sup-store\">\n<div class=\"st\">\n<h4>\u5357\u5bcc\u68ee \u00b7 \u9ad8\u65b0\u5e97<\/h4>\n<p>\ud83d\udccd \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/p>\n<p class=\"nav\">\ud83d\uddfa <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892|30.598786|104.074284|30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97 \u203a<\/a><\/p>\n<p class=\"mgr\">\ud83d\udcf1 \u4f59\u6653\u73b2\uff1a<a href=\"tel:13008113409\">130-0811-3409<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n<p class=\"mgr\">\ud83d\udcf1 \u9ec4\u7ecf\u7406\uff1a<a href=\"tel:15828489188\">158-2848-9188<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n<p class=\"hotline\"><a href=\"tel:02886131795\">028-86131795<\/a><\/p>\n<p style=\"font-size:12px;color:#94a3b8;\">\u5357\u5bcc\u68ee\u70ed\u7ebf \u00b7 \u5168\u5929\u5019\u670d\u52a1<\/p>\n<\/p><\/div>\n<div class=\"st\">\n<h4>\u5317\u5bcc\u68ee \u00b7 \u6210\u534e\u5e97<\/h4>\n<p>\ud83d\udccd \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/p>\n<p class=\"nav\">\ud83d\uddfa <a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547|30.599807|104.07041|30.604665&amp;query_type=IDQ&amp;query=%E6%88%90%E9%83%BD%E6%97%A5%E7%AB%8B%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%99%BA%E6%85%A7%E7%A9%BA%E6%B0%94%E9%A6%86(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8C%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17.5\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97 \u203a<\/a><\/p>\n<p class=\"mgr\">\ud83d\udcf1 \u9ec4\u7ecf\u7406\uff1a<a href=\"tel:15828489188\">158-2848-9188<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n<p class=\"mgr\">\ud83d\udcf1 \u4f59\u7ecf\u7406\uff1a<a href=\"tel:13908183204\">139-0818-3204<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n<p class=\"hotline\"><a href=\"tel:02865272586\">028-65272586<\/a><\/p>\n<p style=\"font-size:12px;color:#94a3b8;\">\u5317\u5bcc\u68ee\u70ed\u7ebf \u00b7 \u5168\u5929\u5019\u670d\u52a1<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8d44\u6599\u6765\u6e90<\/strong>\uff1a\u535a\u4e16\u5b98\u65b9\u6837\u518c\u4e0e\u4ea7\u54c1\u8d44\u6599\uff082024 \u5e74 9 \u6708\u7248\uff09\uff1b\u53c2\u6570\u914d\u7f6e\u4ee5\u8bbe\u5907\u94ed\u724c\u4e0e\u539f\u5382\u6700\u65b0\u8d44\u6599\u4e3a\u51c6\u3002<\/p>\n<\/blockquote>\n<\/blockquote>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/longmai-nt.com\/?page_id=835#faq\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u535a\u4e16\u58c1\u6302\u7089\u503c\u5f97\u4e70\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u535a\u4e16\u6545\u969c\u7387\u4f4e\u3001\u552e\u540e\u7f51\u70b9\u5e7f\u3001\u6027\u4ef7\u6bd4\u7a81\u51fa\uff0c\u51b7\u51dd\u7089\u7ea6 108% \u70ed\u6548\u7387\u3002\u9884\u7b97\u6709\u9650\u9009 G6100W \u5e38\u89c4\uff08\u00a55,850 \u8d77\uff09\uff0c\u8ffd\u6c42\u8282\u80fd\u9009\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\uff08\u00a510,500 \u8d77\uff09\u3002\u8be6\u89c1\u6b63\u6587\u7b2c\u4e09\/\u56db\u7ae0\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u535a\u4e16\u51b7\u51dd\u7089\u548c\u83f2\u65af\u66fc\u600e\u4e48\u9009\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e24\u8005\u5747\u4e3a\u5fb7\u7cfb\u6807\u6746\uff1a\u83f2\u65af\u66fc\u51b7\u51dd\u6280\u672f\uff08\u5168\u7cfb Inox \u4e0d\u9508\u94a2\u6362\u70ed\u5668\uff09\u66f4\u5f3a\u3001\u64cd\u4f5c\u9762\u677f\u504f\u4e13\u4e1a\uff1b\u535a\u4e16\u552e\u540e\u7f51\u70b9\u66f4\u5e7f\u3001\u6027\u4ef7\u6bd4\u66f4\u9ad8\u3002\u957f\u671f\u81ea\u4f4f\u91cd\u7701\u6c14\u9009\u83f2\u65af\u66fc\uff0c\u91cd\u7701\u5fc3\u552e\u540e\u9009\u535a\u4e16\u3002\u8be6\u89c1\u300a\u58c1\u6302\u7089\u600e\u4e48\u9009\u300b\u56db\u54c1\u724c\u6a2a\u8bc4\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u535a\u4e16\u4ef7\u683c\u5305\u542b\u5b89\u88c5\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e0a\u8868\u4e3a\u8bbe\u5907\u53c2\u8003\u4ef7\uff0c\u6700\u7ec8\u6210\u4ea4\u542b\u5b89\u88c5\u914d\u7f6e\u4e0e\u9f99\u8109\u4f18\u60e0\u4ef7\uff0c\u8bf7\u89c1\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b\u6216\u81f4\u7535\u95e8\u5e97\u514d\u8d39\u52d8\u6d4b\u62a5\u4ef7\u3002\"\n      }\n    }\n  ]\n}\n<\/script><br \/>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"@id\": \"https:\/\/longmai-nt.com\/?page_id=835#article\",\n  \"mainEntityOfPage\": { \"@id\": \"https:\/\/longmai-nt.com\/?page_id=835\" },\n  \"headline\": \"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248\",\n  \"description\": \"\u535a\u4e16\u58c1\u6302\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790\uff1aG6100W\u3001G7 \u8ffd\u5149\u3001\u6b27\u6d32\u8d35\u65cf\u3001CONDENS 9000I WM \u7b49\u51b7\u51dd\u7089\u4e0e\u5e38\u89c4\u7089\u7684\u53c2\u6570\u3001\u9002\u7528\u6237\u578b\u4e0e\u6210\u90fd\u53c2\u8003\u4ef7\u683c\u3002\",\n  \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg\",\n  \"author\": { \"@type\": \"Person\", \"@id\": \"https:\/\/longmai-nt.com\/#person-miaoyi\", \"name\": \"\u7f2a\u5f02\" },\n  \"publisher\": { \"@id\": \"https:\/\/longmai-nt.com\/#organization\" },\n  \"datePublished\": \"2026-05-15\",\n  \"dateModified\": \"2026-10-09\",\n  \"inLanguage\": \"zh-Hans\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u535a\u4e16\u58c1\u6302\u7089\u5168\u7cfb\u5217\u7545\u9500\u4ea7\u54c1\u6574\u5408\u8d44\u6599 \u535a\u4e16\u7545 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-835","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u535a\u4e16\u58c1\u6302\u7089\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u9f99\u8109\u6696\u901a\uff0c\u51b7\u51dd\u7089\u4e0e\u91c7\u6696\u70ed\u6c34\u4e24\u7528\u7089\u5168\u7cfb\u5217\uff1a\u8ffd\u51496100\u30017100\u3001\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\u7089\u3001G3260W\u7b49\uff0c\u4ece18kW\u5355\u91c7\u6696\u523035kW\u4e24\u7528\u7089\u8986\u76d6\u4e0d\u540c\u6237\u578b\u3002\u5fb7\u56fd\u5de5\u827a\u3001\u8282\u80fd\u9759\u97f3\uff0c\u5357\u5bcc\u68ee\u4e0e\u6210\u534e\u533a\u4e24\u5e97\u63d0\u4f9b\u6837\u673a\u4f53\u9a8c\u4e0e\u5b89\u88c5\u6848\u4f8b\u53c2\u8003\uff0c\u5e76\u914d\u672c\u5730\u514d\u8d39\u52d8\u6d4b\u3001\u9009\u578b\u5efa\u8bae\u4e0e\u5341\u5e74\u4fdd\u969c\u5f0f\u552e\u540e\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=835\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u535a\u4e16\u58c1\u6302\u7089\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u9f99\u8109\u6696\u901a\uff0c\u51b7\u51dd\u7089\u4e0e\u91c7\u6696\u70ed\u6c34\u4e24\u7528\u7089\u5168\u7cfb\u5217\uff1a\u8ffd\u51496100\u30017100\u3001\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\u7089\u3001G3260W\u7b49\uff0c\u4ece18kW\u5355\u91c7\u6696\u523035kW\u4e24\u7528\u7089\u8986\u76d6\u4e0d\u540c\u6237\u578b\u3002\u5fb7\u56fd\u5de5\u827a\u3001\u8282\u80fd\u9759\u97f3\uff0c\u5357\u5bcc\u68ee\u4e0e\u6210\u534e\u533a\u4e24\u5e97\u63d0\u4f9b\u6837\u673a\u4f53\u9a8c\u4e0e\u5b89\u88c5\u6848\u4f8b\u53c2\u8003\uff0c\u5e76\u914d\u672c\u5730\u514d\u8d39\u52d8\u6d4b\u3001\u9009\u578b\u5efa\u8bae\u4e0e\u5341\u5e74\u4fdd\u969c\u5f0f\u552e\u540e\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=835\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-12T13:25:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"23 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835\",\"name\":\"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/bs-lnl-Condens3260W.jpg\",\"datePublished\":\"2026-05-15T07:59:02+00:00\",\"dateModified\":\"2026-11-12T13:25:11+00:00\",\"description\":\"\u535a\u4e16\u58c1\u6302\u7089\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u9f99\u8109\u6696\u901a\uff0c\u51b7\u51dd\u7089\u4e0e\u91c7\u6696\u70ed\u6c34\u4e24\u7528\u7089\u5168\u7cfb\u5217\uff1a\u8ffd\u51496100\u30017100\u3001\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\u7089\u3001G3260W\u7b49\uff0c\u4ece18kW\u5355\u91c7\u6696\u523035kW\u4e24\u7528\u7089\u8986\u76d6\u4e0d\u540c\u6237\u578b\u3002\u5fb7\u56fd\u5de5\u827a\u3001\u8282\u80fd\u9759\u97f3\uff0c\u5357\u5bcc\u68ee\u4e0e\u6210\u534e\u533a\u4e24\u5e97\u63d0\u4f9b\u6837\u673a\u4f53\u9a8c\u4e0e\u5b89\u88c5\u6848\u4f8b\u53c2\u8003\uff0c\u5e76\u914d\u672c\u5730\u514d\u8d39\u52d8\u6d4b\u3001\u9009\u578b\u5efa\u8bae\u4e0e\u5341\u5e74\u4fdd\u969c\u5f0f\u552e\u540e\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/bs-lnl-Condens3260W.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/bs-lnl-Condens3260W.jpg\",\"width\":1242,\"height\":1762},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=835#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248 - \u9f99\u8109\u6696\u901a","description":"\u535a\u4e16\u58c1\u6302\u7089\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u9f99\u8109\u6696\u901a\uff0c\u51b7\u51dd\u7089\u4e0e\u91c7\u6696\u70ed\u6c34\u4e24\u7528\u7089\u5168\u7cfb\u5217\uff1a\u8ffd\u51496100\u30017100\u3001\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\u7089\u3001G3260W\u7b49\uff0c\u4ece18kW\u5355\u91c7\u6696\u523035kW\u4e24\u7528\u7089\u8986\u76d6\u4e0d\u540c\u6237\u578b\u3002\u5fb7\u56fd\u5de5\u827a\u3001\u8282\u80fd\u9759\u97f3\uff0c\u5357\u5bcc\u68ee\u4e0e\u6210\u534e\u533a\u4e24\u5e97\u63d0\u4f9b\u6837\u673a\u4f53\u9a8c\u4e0e\u5b89\u88c5\u6848\u4f8b\u53c2\u8003\uff0c\u5e76\u914d\u672c\u5730\u514d\u8d39\u52d8\u6d4b\u3001\u9009\u578b\u5efa\u8bae\u4e0e\u5341\u5e74\u4fdd\u969c\u5f0f\u552e\u540e\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=835","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248 - \u9f99\u8109\u6696\u901a","og_description":"\u535a\u4e16\u58c1\u6302\u7089\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u9f99\u8109\u6696\u901a\uff0c\u51b7\u51dd\u7089\u4e0e\u91c7\u6696\u70ed\u6c34\u4e24\u7528\u7089\u5168\u7cfb\u5217\uff1a\u8ffd\u51496100\u30017100\u3001\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\u7089\u3001G3260W\u7b49\uff0c\u4ece18kW\u5355\u91c7\u6696\u523035kW\u4e24\u7528\u7089\u8986\u76d6\u4e0d\u540c\u6237\u578b\u3002\u5fb7\u56fd\u5de5\u827a\u3001\u8282\u80fd\u9759\u97f3\uff0c\u5357\u5bcc\u68ee\u4e0e\u6210\u534e\u533a\u4e24\u5e97\u63d0\u4f9b\u6837\u673a\u4f53\u9a8c\u4e0e\u5b89\u88c5\u6848\u4f8b\u53c2\u8003\uff0c\u5e76\u914d\u672c\u5730\u514d\u8d39\u52d8\u6d4b\u3001\u9009\u578b\u5efa\u8bae\u4e0e\u5341\u5e74\u4fdd\u969c\u5f0f\u552e\u540e\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=835","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-12T13:25:11+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"23 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=835","url":"https:\/\/longmai-nt.com\/?page_id=835","name":"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=835#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=835#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg","datePublished":"2026-05-15T07:59:02+00:00","dateModified":"2026-11-12T13:25:11+00:00","description":"\u535a\u4e16\u58c1\u6302\u7089\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u9f99\u8109\u6696\u901a\uff0c\u51b7\u51dd\u7089\u4e0e\u91c7\u6696\u70ed\u6c34\u4e24\u7528\u7089\u5168\u7cfb\u5217\uff1a\u8ffd\u51496100\u30017100\u3001\u6b27\u6d32\u8d35\u65cf\u51b7\u51dd\u7089\u3001G3260W\u7b49\uff0c\u4ece18kW\u5355\u91c7\u6696\u523035kW\u4e24\u7528\u7089\u8986\u76d6\u4e0d\u540c\u6237\u578b\u3002\u5fb7\u56fd\u5de5\u827a\u3001\u8282\u80fd\u9759\u97f3\uff0c\u5357\u5bcc\u68ee\u4e0e\u6210\u534e\u533a\u4e24\u5e97\u63d0\u4f9b\u6837\u673a\u4f53\u9a8c\u4e0e\u5b89\u88c5\u6848\u4f8b\u53c2\u8003\uff0c\u5e76\u914d\u672c\u5730\u514d\u8d39\u52d8\u6d4b\u3001\u9009\u578b\u5efa\u8bae\u4e0e\u5341\u5e74\u4fdd\u969c\u5f0f\u552e\u540e\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=835#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=835"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=835#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/bs-lnl-Condens3260W.jpg","width":1242,"height":1762},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=835#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u535a\u4e16\u666e\u901a\u58c1\u6302\u7089\uff5c\u5168\u7cfb\u5217\u51b7\u51dd\u7089\u9009\u578b \u5b8c\u6574\u89e3\u6790\u7248"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/835","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=835"}],"version-history":[{"count":25,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/835\/revisions"}],"predecessor-version":[{"id":20286,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/835\/revisions\/20286"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=835"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}