{"id":8475,"date":"2026-07-26T13:38:13","date_gmt":"2026-07-26T05:38:13","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=8475"},"modified":"2026-07-26T13:44:10","modified_gmt":"2026-07-26T05:44:10","slug":"%e5%b4%94%e8%80%81%e5%b8%88%e7%bb%bf%e5%9f%8e%e9%94%a6%e5%9b%ad%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e6%96%b0%e9%a3%8e%e6%96%b9%e6%a1%88%e5%89%8d%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=8475","title":{"rendered":"\u5d14\u8001\u5e08\u7eff\u57ce\u9526\u56ed\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u65b9\u6848\u524d\u4e66"},"content":{"rendered":"\n\n<style>\n:root{\n  --primary:#1a6fb5; --primary-dark:#155a93; --accent:#c0392b; --gold:#b8860b;\n  --bg:#f5f7fa; --bg-card:#fff; --bg-soft:#eef3f8; --border:#e2e8f0;\n  --text:#243240; --text-light:#5b6b7b; --max-width:1200px; --radius:12px; --radius-xl:18px;\n  --shadow:0 2px 10px rgba(20,40,70,.06);\n}\n*{box-sizing:border-box;margin:0;padding:0;}\nbody{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;background:var(--bg);color:var(--text);line-height:1.7;}\na{color:var(--primary);}\n\n\/* ===== \u5c01\u9762 Header ===== *\/\nheader.cover{\n  position:relative;min-height:440px;display:flex;align-items:center;justify-content:center;overflow:hidden;\n  background:linear-gradient(rgba(10,18,30,0.48),rgba(10,18,30,0.48)), url(\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1.png\") center\/cover no-repeat !important;\n}\n.cover-panel{position:relative;z-index:2;max-width:980px;width:90%;padding:40px 44px;background:rgba(8,16,28,.30);border:1px solid rgba(255,255,255,.40);border-radius:var(--radius-xl);box-shadow:0 18px 50px rgba(0,0,0,.25),inset 0 1px 0 rgba(255,255,255,.30);text-shadow:0 1px 6px rgba(0,0,0,.75);}\n.cover-tag{display:inline-block;font-size:13px;letter-spacing:2px;color:#fff;border:1px solid rgba(255,255,255,.55);border-radius:20px;padding:4px 16px;margin-bottom:20px;}\n.cover-panel h1{font-size:33px;color:#fff;line-height:1.42;margin-bottom:12px;font-weight:700;}\n.cover-sub{font-size:15px;color:#fff;margin-bottom:28px;}\n.cover-info{display:grid;grid-template-columns:repeat(2,1fr);gap:12px 24px;}\n.cover-info-item{display:flex;align-items:baseline;gap:8px;}\n.cover-info-item .label{font-size:13px;color:#fff;white-space:nowrap;opacity:.85;}\n.cover-info-item .value{font-size:14px;color:#fff;font-weight:500;}\n\n\/* ===== \u9762\u5305\u5c51 ===== *\/\n.lm-breadcrumb{background:var(--bg-soft);border-bottom:1px solid var(--border);padding:10px 20px;font-size:13px;color:var(--text-light);}\n.lm-breadcrumb ol{list-style:none;margin:0 auto;padding:0;display:flex;flex-wrap:wrap;gap:6px;max-width:var(--max-width);}\n.lm-breadcrumb li:not(:last-child)::after{content:\"\/\";margin-left:6px;color:var(--border);}\n.lm-breadcrumb a{color:var(--primary);text-decoration:none;}\n\n\/* ===== Subnav\uff08\u4e3b\u76ee\u5f55 + \u6298\u53e0\u4e0b\u62c9\u5b50\u76ee\u5f55 \u00b7 7454\u6a21\u677f\uff09 ===== *\/\n.lm-subnav{position:sticky;top:0;z-index:99;background:var(--bg-card);border-bottom:1px solid var(--border);padding:10px 20px;display:flex;justify-content:center;gap:10px;flex-wrap:wrap;box-shadow:0 1px 4px rgba(0,0,0,.04);}\n.lm-nav-toggle,.lm-nav-link{display:inline-flex;align-items:center;gap:5px;color:var(--text-light);text-decoration:none;font-size:12px;padding:6px 12px;border-radius:4px;border:1px solid var(--border);background:transparent;font-family:inherit;cursor:pointer;transition:all .2s;white-space:nowrap;}\n.lm-nav-toggle:hover,.lm-nav-link:hover{color:var(--primary);background:var(--bg-soft);border-color:var(--primary);}\n.lm-nav-toggle[aria-expanded=\"true\"]{color:var(--primary);background:var(--bg-soft);border-color:var(--primary);}\n.lm-caret{font-size:9px;line-height:1;transition:transform .2s ease;}\n.lm-nav-toggle[aria-expanded=\"true\"] .lm-caret{transform:rotate(180deg);}\n.lm-nav-item{position:relative;}\n.lm-nav-panel{display:none;position:absolute;top:calc(100% + 6px);left:0;min-width:150px;max-height:70vh;overflow-y:auto;background:var(--bg-card);border:1px solid var(--border);border-radius:8px;box-shadow:0 10px 30px rgba(0,0,0,.14);padding:6px;z-index:100;flex-direction:column;}\n.lm-nav-panel.open{display:flex;}\n.lm-nav-panel a{color:var(--text-light);text-decoration:none;font-size:12px;padding:7px 10px;border-radius:4px;transition:all .2s;white-space:nowrap;}\n.lm-nav-panel a:hover{color:var(--primary);background:var(--bg-soft);}\n\n\/* ===== \u6b63\u6587\u5bb9\u5668\u4e0e\u901a\u7528\u5361\u7247 ===== *\/\n.lm-wrap{max-width:var(--max-width);margin:0 auto;padding:30px 20px 60px;}\nsection{margin-bottom:46px;scroll-margin-top:70px;}\nh2{font-size:24px;color:var(--primary-dark);margin-bottom:18px;padding-bottom:10px;border-bottom:2px solid var(--primary);}\nh3{font-size:18px;color:var(--primary);margin:22px 0 12px;}\n.lm-lead{color:var(--text-light);font-size:14.5px;margin:6px 0 14px;}\n.lm-card{background:var(--bg-card);border:1px solid var(--border);border-radius:var(--radius);padding:22px;box-shadow:var(--shadow);margin:16px 0;}\n.lm-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(230px,1fr));gap:16px;margin:16px 0;}\n.lm-mini{background:var(--bg-soft);border:1px solid var(--border);border-radius:12px;padding:16px 18px;}\n.lm-mini h4{margin:0 0 6px;color:var(--primary);font-size:15px;}\n.lm-mini p{margin:0;font-size:13.5px;color:var(--text-light);line-height:1.7;}\n.lm-callout{background:linear-gradient(135deg,#eaf3fc,#f4f9ff);border:1px solid #cfe3f6;border-radius:12px;padding:16px 20px;margin:16px 0;font-size:14px;color:var(--text);}\n.lm-callout b{color:var(--primary-dark);}\n.lm-tbl{width:100%;border-collapse:collapse;margin:16px 0;font-size:14px;background:#fff;border-radius:12px;overflow:hidden;box-shadow:var(--shadow);}\n.lm-tbl th{background:var(--primary);color:#fff;padding:12px 14px;text-align:left;font-weight:600;}\n.lm-tbl td{padding:11px 14px;border-bottom:1px solid var(--border);}\n.lm-tbl tr:nth-child(even) td{background:var(--bg-soft);}\n.lm-tbl tr:last-child td{border-bottom:none;}\n.lm-price-final{font-size:20px;color:var(--accent);font-weight:800;}\n.lm-tag-red{display:inline-block;background:var(--accent);color:#fff;font-size:12px;padding:2px 10px;border-radius:12px;margin-left:6px;vertical-align:middle;}\n\n\/* ===== \u7ffb\u8f6c\u5361\uff08\u6b63\u9762\u4ea7\u54c1\u5b9e\u62cd\u56fe \/ \u53cd\u9762\u6027\u80fd\u4ecb\u7ecd\uff09 ===== *\/\n.lm-flip-card{background:transparent;width:280px;height:400px;perspective:1000px;cursor:pointer;display:inline-block;vertical-align:top;margin:8px;}\n.lm-flip-inner{position:relative;width:100%;height:100%;transition:transform .6s;transform-style:preserve-3d;}\n.lm-flip-card.flipped .lm-flip-inner{transform:rotateY(180deg);}\n.lm-flip-front,.lm-flip-back{position:absolute;width:100%;height:100%;backface-visibility:hidden;border-radius:12px;overflow:hidden;box-shadow:var(--shadow);background:#fff;}\n.lm-flip-front{background:linear-gradient(135deg,#1a6fb5,#155a93);}\n.lm-flip-back{transform:rotateY(180deg);padding:20px;overflow-y:auto;}\n.lm-flip-img{width:100%;height:100%;object-fit:contain;background:#eef2f6;padding:8px;display:block;}\n.lm-flip-cap{position:absolute;left:0;right:0;bottom:0;background:linear-gradient(transparent,rgba(8,16,28,.85));color:#fff;padding:14px 16px;font-size:15px;font-weight:700;line-height:1.3;}\n.lm-flip-cap span{display:block;font-size:12px;font-weight:400;opacity:.88;margin-top:2px;}\n.lm-flip-back h4{margin-top:0;color:var(--primary);}\n.lm-flip-back ul{padding-left:18px;font-size:13px;line-height:1.8;margin:8px 0 14px;}\n.lm-freshair-grid{display:flex;flex-wrap:wrap;gap:14px;margin:16px 0;justify-content:flex-start;}\n\n\/* ===== \u7ae0\u8282\u7ea7\u7ffb\u8f6c\u5361\uff08S1 \u5ba2\u6237\u76ee\u6807 \/ \u9762\u79ef\u8d1f\u8377\uff09 ===== *\/\n.lm-flip-section{display:block;width:100%;max-width:780px;height:460px;margin:20px auto;}\n.lm-flip-section .lm-flip-front{display:flex;flex-direction:column;justify-content:center;padding:32px;}\n.lm-flip-section .lm-flip-back{padding:26px 28px;}\n.lm-flip-front-soft{background:linear-gradient(135deg,#1a3a5c,#2c5f8a)!important;color:#fff;}\n.lm-flip-kicker{display:inline-block;align-self:flex-start;font-size:13px;letter-spacing:1px;color:#b8860b;font-weight:700;margin-bottom:16px;background:rgba(255,255,255,.12);padding:5px 14px;border-radius:20px;}\n.lm-flip-lead{font-size:16px;line-height:2;margin:0;font-weight:500;}\n.lm-flip-hint{margin-top:24px;align-self:flex-start;font-size:13px;opacity:.92;background:rgba(255,255,255,.16);padding:7px 16px;border-radius:20px;}\n.lm-goal-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin-top:8px;}\n.lm-goal{background:var(--bg-soft);border:1px solid var(--border);border-radius:10px;padding:14px;font-size:13px;line-height:1.7;}\n.lm-goal b{display:block;color:var(--primary);margin-bottom:6px;font-size:14px;}\n@media(max-width:560px){.lm-flip-section{height:520px;}.lm-goal-grid{grid-template-columns:1fr;}}\n\n\/* ===== \u5185\u94fe \/ \u8bc1\u4e66 \/ \u95e8\u5e97 ===== *\/\n.lm-intlink{display:inline-block;margin:6px 0;color:var(--primary);font-weight:600;text-decoration:none;border-bottom:2px solid var(--gold);padding-bottom:1px;}\n.lm-intlink:hover{color:var(--accent);}\n.lm-store{display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:16px;margin:16px 0;}\n.lm-store .lm-card h4{color:var(--primary);margin-bottom:8px;}\n\n\/* ===== \u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97\uff08\u8bc1\u4e66\/\u95e8\u5e97\u56fe\u96c6\uff09 ===== *\/\n.lm-cert-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:14px 0;}\n.lm-cert-grid figure{margin:0;background:var(--bg-card);border:1px solid var(--border);border-radius:10px;overflow:hidden;transition:box-shadow .2s;}\n.lm-cert-grid figure:hover{box-shadow:0 4px 16px rgba(0,0,0,.08);}\n.lm-cert-img-wrap{width:100%;aspect-ratio:3\/2;overflow:hidden;background:#f8f8f8;display:flex;align-items:center;justify-content:center;}\n.lm-cert-img-wrap img{width:100%;height:100%;object-fit:contain;padding:8px;display:block;}\n.lm-cert-grid figcaption{font-size:.78rem;color:var(--text);padding:8px 10px;text-align:center;font-weight:600;}\n.lm-store-grid{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:14px 0;}\n.lm-store-grid figure{margin:0;border:1px solid var(--border);border-radius:12px;overflow:hidden;background:var(--bg-card);transition:box-shadow .2s;}\n.lm-store-grid figure:hover{box-shadow:0 4px 16px rgba(0,0,0,.08);}\n.lm-store-img-wrap{width:100%;aspect-ratio:16\/9;overflow:hidden;background:#f8f8f8;}\n.lm-store-img-wrap img{width:100%;height:100%;object-fit:cover;display:block;}\n.lm-store-grid figcaption{padding:12px 14px;}\n.lm-store-grid .lm-store-name{font-weight:700;color:var(--primary);font-size:.92rem;margin-bottom:6px;}\n.lm-store-grid .lm-addr{font-size:.8rem;color:var(--text);margin:2px 0;line-height:1.5;}\n.lm-cert-grid figure.lm-img-fail .lm-cert-img-wrap,.lm-store-grid figure.lm-img-fail .lm-store-img-wrap{position:relative;min-height:130px;background:#f3f3f3;}\n.lm-cert-grid figure.lm-img-fail img,.lm-store-grid figure.lm-img-fail img{display:none;}\n.lm-cert-grid figure.lm-img-fail .lm-cert-img-wrap::after,.lm-store-grid figure.lm-img-fail .lm-store-img-wrap::after{content:\"\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d\\A\u8bf7\u7528\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\";white-space:pre;text-align:center;color:#a07878;font-size:.78rem;padding:16px;display:block;}\n@media(max-width:560px){.lm-cert-grid{grid-template-columns:1fr;}.lm-store-grid{grid-template-columns:1fr;}}\n\n\/* ===== FAQ \/ \u5ef6\u4f38\u9605\u8bfb \/ \u9875\u811a ===== *\/\n.lm-faq-item{background:#fff;border:1px solid var(--border);border-radius:12px;padding:16px 20px;margin:12px 0;box-shadow:var(--shadow);}\n.lm-faq-item b{color:var(--primary-dark);}\n.lm-links{display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:14px;margin:16px 0;}\n.lm-links a{display:block;background:#fff;border:1px solid var(--border);border-radius:12px;padding:14px 18px;text-decoration:none;color:var(--text);box-shadow:var(--shadow);}\n.lm-links a:hover{border-color:var(--primary);color:var(--primary);}\nfooter{background:var(--primary-dark);color:#fff;text-align:center;padding:28px 20px;font-size:13px;}\nfooter a{color:#fff;}\n\n@media(max-width:720px){\n  .lm-subnav{flex-wrap:wrap;}\n  .cover-info{grid-template-columns:1fr;}\n  .cover-panel h1{font-size:25px;}\n}\n<\/style>\n\n<!-- ===== \u5c01\u9762 Header ===== -->\n<header class=\"cover\">\n  <div class=\"cover-panel\">\n    <div class=\"cover-tag\">\u9f99\u8109\u6696\u901a \u00b7 \u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce \u4e09\u7cfb\u7edf\u65b9\u6848\u524d\u4e66<\/div>\n    <h1>\u5d14\u8001\u5e08\u00b7\u7eff\u57ce\u9526\u56ed9\u680b \u4e09\u6052\u8212\u9002\u5bb6\u7cfb\u7edf\u65b9\u6848\u524d\u4e66<\/h1>\n    <div class=\"cover-sub\">94\u33a1\u5e73\u5c42 \u00b7 \u65e5\u7acb\u8212\u4eabEX\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8282\u80fd\u578b\u5730\u6696\uff08\u4e2d\u592e\u8054\u52a8\uff09 + \u65e5\u7acb\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/div>\n    <div class=\"cover-info\">\n      <div class=\"cover-info-item\"><span class=\"label\">\u4e1a\u4e3b<\/span><span class=\"value\">\u5d14\u8001\u5e08\uff08\u81ea\u4f4f\u623f\u4ea7\u4ee3\u7ba1\uff09<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u9879\u76ee<\/span><span class=\"value\">\u6210\u90fd\u00b7\u7eff\u57ce\u9526\u56ed 9\u680b<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u5957\u5185\u9762\u79ef<\/span><span class=\"value\">94 \u33a1 \u00b7 \u56db\u5ba4\u5e73\u5c42<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u65b9\u6848\u987e\u95ee<\/span><span class=\"value\">\u4f59\u7231\u82f1 \u00b7 \u4ece\u4e1a14\u5e74<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u7cfb\u7edf\u914d\u7f6e<\/span><span class=\"value\">\u7a7a\u8c035\u5185\u673a \u00b7 \u5730\u66964\u533a \u00b7 \u65b0\u98ce178m\u00b3\/h<\/span><\/div>\n      <div class=\"cover-info-item\"><span class=\"label\">\u7f16\u5236\u65e5\u671f<\/span><span class=\"value\">2026-07-21 \u00b7 \u5357\u5bcc\u68ee\u95e8\u5e97<\/span><\/div>\n    <\/div>\n  <\/div>\n<\/header>\n\n<!-- ===== \u9762\u5305\u5c51 ===== -->\n<nav class=\"lm-breadcrumb\" aria-label=\"breadcrumb\"><ol>\n  <li><a href=\"https:\/\/longmai-nt.com\">\u9f99\u8109\u6696\u901a<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=2705\">\u65b9\u6848\u4e2d\u5fc3<\/a><\/li>\n  <li aria-current=\"page\">\u5d14\u8001\u5e08\u00b7\u7eff\u57ce\u9526\u56ed \u4e09\u7cfb\u7edf\u65b9\u6848\u524d\u4e66<\/li>\n<\/ol><\/nav>\n\n<!-- ===== \u76ee\u5f55\u5bfc\u822a\uff08\u4e3b\u76ee\u5f55 + \u6298\u53e0\u4e0b\u62c9\u5b50\u76ee\u5f55 \u00b7 7454\u6a21\u677f\uff09 ===== -->\n<nav class=\"lm-subnav\" aria-label=\"\u76ee\u5f55\u5bfc\u822a\">\n  <div class=\"lm-nav-item\">\n    <button class=\"lm-nav-toggle\" data-target=\"nav-s1\" aria-expanded=\"false\">S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 <span class=\"lm-caret\">\u25be<\/span><\/button>\n    <div class=\"lm-nav-panel\" id=\"nav-s1\">\n      <a href=\"#s1\">\u5ba2\u6237\u6210\u529f\u76ee\u6807\uff08\u7ffb\u8f6c\uff09<\/a>\n      <a href=\"#s1-area\">\u9762\u79ef\u8d1f\u8377\u5206\u6790\uff08\u7ffb\u8f6c\uff09<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-nav-item\">\n    <button class=\"lm-nav-toggle\" data-target=\"nav-s2\" aria-expanded=\"false\">S2\u00b7\u9700\u6c42\u75db\u70b9\u8bca\u65ad <span class=\"lm-caret\">\u25be<\/span><\/button>\n    <div class=\"lm-nav-panel\" id=\"nav-s2\">\n      <a href=\"#s2\">\u75db\u70b9\u8bca\u65ad<\/a>\n      <a href=\"#s2-brand\">\u65e5\u7acb vs \u683c\u529b<\/a>\n      <a href=\"#s2-floor\">\u901a\u914d\u578b vs \u8282\u80fd\u578b<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-nav-item\">\n    <button class=\"lm-nav-toggle\" data-target=\"nav-s3\" aria-expanded=\"false\">S3\u00b7\u914d\u7f6e\u4e0e\u62a5\u4ef7 <span class=\"lm-caret\">\u25be<\/span><\/button>\n    <div class=\"lm-nav-panel\" id=\"nav-s3\">\n      <a href=\"#s3-ac\">\u7a7a\u8c03\u914d\u7f6e<\/a>\n      <a href=\"#s3-floor\">\u5730\u6696\u914d\u7f6e<\/a>\n      <a href=\"#s3-fresh\">\u65b0\u98ce\u914d\u7f6e<\/a>\n      <a href=\"#s3-sum\">\u6574\u88c5\u6253\u5305\u62a5\u4ef7<\/a>\n    <\/div>\n  <\/div>\n  <a class=\"lm-nav-link\" href=\"#s4\">S4\u00b7\u65bd\u5de5\u4ea4\u4ed8\u4fdd\u969c<\/a>\n  <a class=\"lm-nav-link\" href=\"#s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<\/a>\n  <a class=\"lm-nav-link\" href=\"#showroom\">\u95e8\u5e97\u670d\u52a1<\/a>\n  <a class=\"lm-nav-link\" href=\"#faq\">FAQ<\/a>\n  <a class=\"lm-nav-link\" href=\"#links\">\u5ef6\u4f38\u9605\u8bfb<\/a>\n<\/nav>\n\n<div class=\"lm-wrap\">\n\n<!-- ===== S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807 ===== -->\n<section id=\"s1\">\n  <h2>S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n  <!-- S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807 \u00b7 \u7ffb\u8f6c\u5361 -->\n  <div class=\"lm-flip-card lm-flip-section\" onclick=\"this.classList.toggle('flipped')\" title=\"\u5ba2\u6237\u6210\u529f\u76ee\u6807 \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u67e5\u770b\u56db\u4e2a\u76ee\u6807\">\n    <div class=\"lm-flip-inner\">\n      <!-- \u6b63\u9762\uff1a\u9009\u578b\u7b2c\u4e00\u539f\u5219 -->\n      <div class=\"lm-flip-front lm-flip-front-soft\">\n        <span class=\"lm-flip-kicker\">S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/span>\n        <p class=\"lm-flip-lead\">\u5d14\u8001\u5e08\u4e3a\u59d0\u59d0\u7684\u7eff\u57ce\u9526\u56ed 9\u680b\u623f\u4ea7\u7edf\u7b79\u88c5\u4fee\uff0c\u623f\u5b50\u662f\u81ea\u4f4f\u957f\u671f\u4f7f\u7528\uff0c\u56e0\u6b64\u4ece\u4e00\u5f00\u59cb\u5c31\u628a\u300c\u4f4f\u5f97\u8212\u9002\u3001\u957f\u671f\u7701\u94b1\u3001\u54c1\u8d28\u53ef\u9760\u300d\u4f5c\u4e3a\u9009\u578b\u7b2c\u4e00\u539f\u5219\uff0c\u613f\u610f\u5728\u524d\u671f\u591a\u6295\u5165\u4e00\u70b9\uff0c\u6362\u6765\u540e\u671f\u5341\u51e0\u5e74\u7684\u4f4e\u80fd\u8017\u4e0e\u4f4e\u6545\u969c\u3002<\/p>\n        <span class=\"lm-flip-hint\">\ud83d\udc46 \u70b9\u51fb\u7ffb\u8f6c \u00b7 \u67e5\u770b\u56db\u4e2a\u6210\u529f\u76ee\u6807<\/span>\n      <\/div>\n      <!-- \u53cd\u9762\uff1a\u56db\u4e2a\u6210\u529f\u76ee\u6807 -->\n      <div class=\"lm-flip-back\">\n        <h4>\u56db\u4e2a\u6210\u529f\u76ee\u6807<\/h4>\n        <div class=\"lm-goal-grid\">\n          <div class=\"lm-goal\"><b>\u76ee\u6807\u4e00 \u00b7 \u5168\u5c4b\u6052\u6e29\u6052\u51c0<\/b>\u590f\u5b63\u5236\u51b7\u3001\u51ac\u5b63\u5730\u6696\u3001\u56db\u5b63\u65b0\u98ce\uff0c\u4e00\u5957\u7cfb\u7edf\u89e3\u51b3\u6e29\u5ea6\u4e0e\u7a7a\u6c14\u54c1\u8d28\uff0c\u8ba9 94\u33a1 \u5e73\u5c42\u5b9e\u73b0&#8221;\u8fdb\u95e8\u5c31\u8212\u670d&#8221;\u3002<\/div>\n          <div class=\"lm-goal\"><b>\u76ee\u6807\u4e8c \u00b7 \u957f\u671f\u8d8a\u7528\u8d8a\u7701<\/b>\u4e0d\u770b\u4e00\u6b21\u6027\u6295\u5165\u7684\u9ad8\u4f4e\uff0c\u800c\u770b 10 \u5e74\u603b\u8d26\u3002\u9009\u9ad8\u80fd\u6548\u65e5\u7acb\u7a7a\u8c03 + \u8282\u80fd\u578b\u5730\u6696 + \u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u628a\u6bcf\u5e74\u7535\u8d39\u6c14\u8d39\u538b\u5230\u6700\u4f4e\u3002<\/div>\n          <div class=\"lm-goal\"><b>\u76ee\u6807\u4e09 \u00b7 \u5927\u724c+\u9759\u97f3+\u6d01\u51c0<\/b>\u8ba4\u53ef\u65e5\u7acb\u54c1\u724c\u529b\uff0c\u770b\u91cd\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u4e0e\u5ba4\u5185\u7a7a\u6c14\u6d01\u51c0\u5ea6\uff0c\u613f\u4e3a\u8212\u9002\u5ea6\u4e0e\u8282\u80fd\u6027\u4e70\u5355\u3002<\/div>\n          <div class=\"lm-goal\"><b>\u76ee\u6807\u56db \u00b7 \u4e00\u7ad9\u5f0f\u65e0\u5fe7\u4ea4\u4ed8<\/b>\u4e09\u7cfb\u7edf\u7531\u9f99\u8109\u6696\u901a\u4e00\u5bb6\u7edf\u7b79\u8bbe\u8ba1\u3001\u65bd\u5de5\u3001\u8054\u4fdd\uff0c\u907f\u514d\u591a\u5934\u5bf9\u63a5\u3001\u8d23\u4efb\u63a8\u8bff\u3002<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s1-goal\">\u6210\u529f\u76ee\u6807\u5b9a\u4e49\uff08\u53ef\u91cf\u5316\uff09<\/h3>\n  <div class=\"lm-callout\">\n    <b>\u9a8c\u6536\u5373\u6210\u529f\uff1a<\/b>\u590f\u5b63\u5ba4\u5185 24~26\u2103\u3001\u51ac\u5b63\u5730\u9762 18~22\u2103\u3001\u5ba4\u5185 CO\u2082 \u4e0e PM2.5 \u5168\u5e74\u53ef\u63a7\uff1b\u7a7a\u8c03\u5916\u673a\u77ed\u9014\u79bb\u5bb6 1W \u5f85\u673a\u3001\u5367\u5ba4\u5185\u673a\u566a\u97f3\u4f4e\u81f3 17dB(A)\uff1b\u5730\u6696\u5ba4\u6e29\u8054\u52a8\u9505\u7089\u542f\u505c\uff0c\u5b9e\u73b0&#8221;\u4eba\u5728\u5219\u6696\u3001\u4eba\u8d70\u5219\u7701&#8221;\u3002\u4e09\u7cfb\u7edf\u6574\u88c5\u6253\u5305\u4e00\u6b21\u6027\u9501\u5b9a <b>60,800 \u5143<\/b>\uff0c\u65e0\u9690\u6027\u589e\u9879\u3002\n  <\/div>\n\n  <!-- \u9762\u79ef\u8d1f\u8377\u5206\u6790 \u00b7 \u7ffb\u8f6c\u5361\uff08\u6b63\u9762\u8bbe\u8ba1\u6837\u56fe \/ \u53cd\u9762\u9762\u79ef\u53c2\u6570\uff09 -->\n  <div class=\"lm-flip-card lm-flip-section\" id=\"s1-area\" onclick=\"this.classList.toggle('flipped')\" title=\"\u9762\u79ef\u8d1f\u8377\u5206\u6790 \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u9762\u79ef\u53c2\u6570\">\n    <div class=\"lm-flip-inner\">\n      <!-- \u6b63\u9762\uff1a\u8bbe\u8ba1\u6837\u56fe -->\n      <div class=\"lm-flip-front\" style=\"background:#eef2f6;padding:0;\">\n        <img decoding=\"async\" class=\"lm-flip-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed9\u680b \u8bbe\u8ba1\u6837\u56fe\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <div class=\"lm-flip-cap\">\u9762\u79ef\u8d1f\u8377\u5206\u6790 \u00b7 \u8bbe\u8ba1\u6837\u56fe<span>\u70b9\u51fb\u7ffb\u8f6c\u770b\u9762\u79ef\u53c2\u6570 \u21bb<\/span><\/div>\n      <\/div>\n      <!-- \u53cd\u9762\uff1a\u9762\u79ef\u53c2\u6570 -->\n      <div class=\"lm-flip-back\">\n        <h4>\u9762\u79ef\u8d1f\u8377\u5206\u6790\uff08\u4f9d GB 50736 \/ JGJ 142 \/ JGJ440\uff09<\/h4>\n        <table class=\"lm-tbl\">\n          <thead><tr><th>\u7a7a\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u7a7a\u8c03\u51b7\u91cf(W)<\/th><th>\u5730\u6696\u5236\u70ed\u91cf(W)<\/th><th>\u65b0\u98ce\u91cf(m\u00b3\/h)<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td>\u5ba2\u9910\u5385+\u5f00\u653e\u5f0f\u53a8\u623f<\/td><td>58<\/td><td>6300 + 5600\uff08\u53cc\u673a\uff09<\/td><td>5800<\/td><td>110<\/td><\/tr>\n            <tr><td>\u4e3b\u5367<\/td><td>19<\/td><td>4000<\/td><td>1900<\/td><td>36<\/td><\/tr>\n            <tr><td>\u6b21\u5367<\/td><td>9.5<\/td><td>2200<\/td><td>950<\/td><td>18<\/td><\/tr>\n            <tr><td>\u4e66\u623f<\/td><td>7.5<\/td><td>1800<\/td><td>750<\/td><td>14<\/td><\/tr>\n            <tr><td><b>\u5408\u8ba1<\/b><\/td><td><b>94<\/b><\/td><td><b>19900\uff085\u53f0\u5185\u673a\uff09<\/b><\/td><td><b>9400<\/b><\/td><td><b>178<\/b><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <p class=\"lm-lead\">\u5ba2\u9910\u5385+\u5f00\u653e\u5f0f\u53a8\u623f 58\u33a1\u4e3a\u5927\u5f00\u95f4\uff0c\u91c7\u7528 RPIZ-63 + RPIZ-56 \u53cc\u5185\u673a\u5206\u533a\u9001\u98ce\uff0c\u907f\u514d\u5355\u673a\u98ce\u7a0b\u8fc7\u957f\u3001\u51b7\u70ed\u4e0d\u5747\uff1b\u5367\u5ba4\u4e66\u623f\u5404 1 \u53f0\uff0c\u505a\u5230&#8221;\u4e00\u5ba4\u4e00\u63a7&#8221;\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad ===== -->\n<section id=\"s2\">\n  <h2>S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/h2>\n  <div class=\"lm-grid\">\n    <div class=\"lm-mini\"><h4>\u75db\u70b9\u2460 \u54c1\u724c\u7ea0\u7ed3<\/h4><p>\u5d14\u8001\u5e08\u6700\u521d\u5728\u683c\u529b\u4e0e\u65e5\u7acb\u4e4b\u95f4\u72b9\u8c6b\uff0c\u8ba4\u4e3a&#8221;\u7a7a\u8c03\u90fd\u5dee\u4e0d\u591a&#8221;\u3002<\/p><\/div>\n    <div class=\"lm-mini\"><h4>\u75db\u70b9\u2461 \u6015\u5730\u6696\u8d39\u6c14<\/h4><p>\u62c5\u5fc3\u5730\u6696\u662f&#8221;\u7535\u8001\u864e\/\u6c14\u8001\u864e&#8221;\uff0c\u51ac\u5929\u5f00\u4e00\u4e2a\u6708\u5fc3\u75bc\u3002<\/p><\/div>\n    <div class=\"lm-mini\"><h4>\u75db\u70b9\u2462 \u51b7\u70ed\u6e90\u6d6a\u8d39<\/h4><p>\u5f00\u7a7a\u8c03\u5730\u6696\u9700\u8981\u5bc6\u95ed\u623f\u95f4\uff0c\u957f\u671f\u4e0d\u901a\u98ce\u53c8\u95f7\u53c8\u5e72\uff0c\u6015\u5f00\u7a97\u628a\u51b7\u70ed\u767d\u767d\u653e\u8dd1\u3002<\/p><\/div>\n    <div class=\"lm-mini\"><h4>\u75db\u70b9\u2463 \u5367\u5ba4\u566a\u97f3<\/h4><p>\u7761\u7720\u654f\u611f\uff0c\u62c5\u5fc3\u5185\u673a\u591c\u91cc\u55e1\u55e1\u54cd\u5f71\u54cd\u4f11\u606f\u3002<\/p><\/div>\n  <\/div>\n\n  <h3 id=\"s2-brand\">\u8bca\u65ad\u4e00\uff1a\u65e5\u7acb vs \u683c\u529b\uff0c\u4ef7\u683c\u63a5\u8fd1\u65f6\u5982\u4f55\u9009\uff1f<\/h3>\n  <p class=\"lm-lead\">\u7ecf\u6211\u4eec\u8bb2\u89e3\uff0c\u5d14\u8001\u5e08\u610f\u8bc6\u5230\u54c1\u724c\u4e4b\u95f4\u7684\u5dee\u8ddd\u4e0d\u5728&#8221;\u5236\u4e0d\u5236\u51b7&#8221;\uff0c\u800c\u5728<strong>\u8212\u9002\u5ea6\u4e0e\u8282\u80fd\u6027<\/strong>\u2014\u2014\u540c\u6837\u7684\u4ef7\u4f4d\uff0c\u65e5\u7acb\u5728\u538b\u7f29\u673a\u3001\u9759\u97f3\u3001\u6d01\u51c0\u3001\u80fd\u6548\u4e0a\u66f4\u80dc\u4e00\u7b79\u3002\u5728\u4e24\u8005\u4ef7\u683c\u5dee\u5f02\u4e0d\u5927\u7684\u524d\u63d0\u4e0b\uff0c\u5d14\u8001\u5e08\u679c\u65ad\u9009\u62e9\u65e5\u7acb\u8212\u4eab EX \u7cfb\u5217\u3002<\/p>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u65e5\u7acb \u8212\u4eabEX\uff08RAS-160HRNAQ\uff09<\/th><th>\u540c\u4ef7\u4f4d\u7ade\u54c1\uff08\u683c\u529b\uff09<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u538b\u7f29\u673a<\/td><td>\u65b0\u4e00\u4ee3\u5168\u76f4\u6d41\u53d8\u9891 + \u516d\u8109\u6ce2\u7535\u78c1\u52a0\u70ed\u6280\u672f<\/td><td>\u5e38\u89c4\u53d8\u9891\u538b\u7f29\u673a<\/td><\/tr>\n      <tr><td>\u80fd\u6548 APF<\/td><td>APF 5.80\uff08\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\uff09<\/td><td>\u4e00\u7ea7\u80fd\u6548\u4e34\u754c\u503c<\/td><\/tr>\n      <tr><td>\u9759\u97f3<\/td><td>\u5185\u673a\u6700\u4f4e 17dB(A)\uff1b\u5916\u673a\u591c\u95f4\u9759\u97f3\u518d\u964d 9dB(A)<\/td><td>\u5e38\u89c4\u9759\u97f3\uff0c\u591c\u95f4\u65e0\u4e13\u95e8\u964d\u566a<\/td><\/tr>\n      <tr><td>\u6d01\u51c0\u5ea6<\/td><td>\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01 + 60\u2103\u9ad8\u6e29\u9664\u83cc + \u53ef\u9009 PE \u7eaf\u51c0\u6a21\u5757\uff08\u9664 PM2.5\/\u7532\u919b\uff09<\/td><td>\u666e\u901a\u6ee4\u7f51\uff0c\u9700\u4eba\u5de5\u9891\u7e41\u6e05\u6d17<\/td><\/tr>\n      <tr><td>\u9632\u6f0f\u6c34<\/td><td>\u6807\u914d\u6c34\u6cf5 + \u6d6e\u5b50\u5f00\u5173\uff0c\u675c\u7edd\u6f0f\u6c34\u6ce1\u9876<\/td><td>\u90e8\u5206\u673a\u578b\u9700\u53e6\u914d\u63d0\u5347\u6cf5<\/td><\/tr>\n      <tr><td>\u4f4e\u6e29\u5236\u70ed<\/td><td>-23\u2103~17\u2103\u7a33\u5b9a\u5236\u70ed\uff0c59\u2103\u9ad8\u6e29\u4e0d\u8870\u51cf<\/td><td>\u4f4e\u6e29\u5236\u70ed\u8870\u51cf\u8f83\u660e\u663e<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 EX-\u8212\u4eab\u7cfb\u5217\u8be6\u89e3 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n\n  <h3 id=\"s2-floor\">\u8bca\u65ad\u4e8c\uff1a\u5730\u6696\u901a\u914d\u578b vs \u8282\u80fd\u578b\uff0c\u4e3a\u4ec0\u4e48\u9009\u8282\u80fd\u578b\uff1f<\/h3>\n  <p class=\"lm-lead\">\u6211\u4eec\u540c\u65f6\u63d0\u4f9b\u5e02\u573a\u901a\u914d\u578b\u4e0e\u8282\u80fd\u578b\u4e24\u5957\u5730\u6696\u65b9\u6848\u3002\u5d14\u8001\u5e08\u7b97\u4e86\u4e00\u7b14&#8221;\u957f\u671f\u8d26&#8221;\uff1a\u623f\u5b50\u957f\u671f\u81ea\u4f4f\uff0c\u8282\u80fd\u578b\u524d\u671f\u591a\u6295\u5165\u4e00\u4e9b\uff0c\u4f46\u914d<strong>\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u53d8\u9891\u9505\u7089 + \u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u7cfb\u7edf<\/strong>\uff0c\u8d8a\u7528\u8d8a\u7701\uff0c\u7ea6\u4e09\u5e74\u5373\u53ef\u7528\u7701\u4e0b\u7684\u6c14\u8d39\u56de\u672c\uff0c\u4e4b\u540e\u6bcf\u5e74\u90fd\u662f\u51c0\u7701\u3002\u5979\u679c\u65ad\u9009\u62e9\u8282\u80fd\u578b\uff0c\u5e76\u52a0\u88c5\u5730\u6696\u4e2d\u592e\u8054\u52a8\u63a7\u5236\u3002<\/p>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u5e02\u573a\u901a\u914d\u578b<\/th><th>\u8282\u80fd\u578b\uff08\u5d14\u8001\u5e08\u6240\u9009\uff09<span class=\"lm-tag-red\">\u5df2\u9009<\/span><\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u9505\u7089<\/td><td>\u5e38\u89c4\u5b9a\u9891\/\u4e24\u6bb5\u7089<\/td><td>\u66fc\u745e\u5fb7 L1PB24 \u5206\u6bb5\u71c3\u70e7\u53d8\u9891\u7089<\/td><\/tr>\n      <tr><td>\u63a7\u5236<\/td><td>\u624b\u52a8\/\u5355\u70b9\u6e29\u63a7<\/td><td>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff0c\u4eba\u8d70\u81ea\u52a8\u964d\u8d1f\u8377<\/td><\/tr>\n      <tr><td>\u76d8\u7ba1<\/td><td>\u666e\u901a\u76d8\u7ba1<\/td><td>\u4f1f\u661f PE-RT + \u955c\u9762\u53cd\u5c04\u819c + \u6324\u5851\u677f\u4fdd\u6e29<\/td><\/tr>\n      <tr><td>\u957f\u671f\u80fd\u8017<\/td><td>\u57fa\u51c6<\/td><td>\u8054\u52a8\u8282\u80fd\uff0c\u957f\u671f\u6c14\u8d39\u663e\u8457\u66f4\u4f4e<\/td><\/tr>\n      <tr><td>\u56de\u672c\u5468\u671f<\/td><td>\u2014<\/td><td>\u7ea6 3 \u5e74\u7528\u7701\u4e0b\u7684\u6c14\u8d39\u56de\u672c\uff0c\u4e4b\u540e\u51c0\u7701<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u5730\u6696\u7cfb\u7edf\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a>\n\n  <h3 id=\"s2-fresh\">\u8bca\u65ad\u4e09\uff1a\u4e3a\u4ec0\u4e48\u4e00\u5b9a\u8981\u52a0\u65b0\u98ce\uff1f<\/h3>\n  <div class=\"lm-callout\">\n    \u5f00\u7a7a\u8c03\u3001\u5f00\u5730\u6696\u90fd\u9700\u8981\u5173\u7a97\u4fdd\u6e29\uff0c\u4f46\u957f\u671f\u5bc6\u95ed\u4f1a\u5bfc\u81f4 CO\u2082 \u5347\u9ad8\u3001\u7a7a\u6c14\u53d8\u95f7\u53d8\u5e72\u3002\u82e5\u9760\u5f00\u7a97\u901a\u98ce\uff0c\u7b49\u4e8e\u628a\u82b1\u94b1\u5236\u9020\u7684\u51b7\u70ed\u6e90\u76f4\u63a5\u653e\u8dd1\u3002<b>\u89e3\u51b3\u529e\u6cd5\uff1a\u65e5\u7acb\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/b>\u2014\u2014\u6392\u98ce\u65f6\u56de\u6536 70%+ \u7684\u80fd\u91cf\u9884\u5904\u7406\u65b0\u98ce\uff0c\u65e2\u6362\u6c14\u53c8\u4e0d\u6d6a\u8d39\u51b7\u70ed\u6e90\uff0c\u6027\u4ef7\u6bd4\u9ad8\u3002\u5d14\u8001\u5e08\u679c\u65ad\u589e\u52a0\u8fd9\u5957\u7cfb\u7edf\u3002\n  <\/div>\n  <a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u65e5\u7acb\u65b0\u98ce\u7cfb\u7edf\u4ea7\u54c1\u53c2\u6570 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n<\/section>\n\n<!-- ===== S3 \u00b7 \u914d\u7f6e\u4e0e\u62a5\u4ef7 ===== -->\n<section id=\"s3\">\n  <h2>S3 \u00b7 \u7cfb\u7edf\u914d\u7f6e\u4e0e\u6574\u88c5\u62a5\u4ef7<\/h2>\n\n  <h3 id=\"s3-ac\">\u4e00\u3001\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\uff08\u8212\u4eabEX \u00b7 160\u5916\u673a\u62d65\u53f0\u5185\u673a\uff09<\/h3>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u5408\u8ba1(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u65e5\u7acb<\/td><td>\u7a7a\u6c14\u6e90\u70ed\u6cf5\u5ba4\u5916\u673a<\/td><td>RAS-160HRNAQ<\/td><td>1 \u53f0<\/td><td>17150<\/td><td>17150<\/td><\/tr>\n      <tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5185\u673a\uff08\u5ba2\u9910\u5385\uff09<\/td><td>RPIZ-63FSNAQD\/P<\/td><td>1 \u53f0<\/td><td>6820<\/td><td>6820<\/td><\/tr>\n      <tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5185\u673a\uff08\u5ba2\u9910\u5385\uff09<\/td><td>RPIZ-56FSNAQD\/P<\/td><td>1 \u53f0<\/td><td>6720<\/td><td>6720<\/td><\/tr>\n      <tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5185\u673a\uff08\u4e3b\u5367\uff09<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>1 \u53f0<\/td><td>6440<\/td><td>6440<\/td><\/tr>\n      <tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5185\u673a\uff08\u6b21\u5367\uff09<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1 \u53f0<\/td><td>6250<\/td><td>6250<\/td><\/tr>\n      <tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5185\u673a\uff08\u4e66\u623f\uff09<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>1 \u53f0<\/td><td>6050<\/td><td>6050<\/td><\/tr>\n      <tr><td>\u65e5\u7acb<\/td><td>WiFi \u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>5 \u4e2a<\/td><td>275<\/td><td>1375<\/td><\/tr>\n      <tr><td colspan=\"5\"><b>\u7a7a\u8c03\u7cfb\u7edf\u5408\u8ba1\uff08\u542b\u98ce\u53e3\u3001\u7ba1\u8def\u3001\u4fdd\u6e29\u3001\u63a7\u5236\u3001\u4eba\u5de5\u8f85\u6750\uff0c\u5305\u5de5\u5305\u6599\uff09<\/b><\/td><td><b>50,805<\/b><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"lm-callout\">\n    <b>\u8d85\u914d\u7387\u6838\u7b97\uff1a<\/b>\u5185\u673a\u603b\u51b7\u91cf 19,900W \u00f7 \u5916\u673a\u989d\u5b9a\u5236\u51b7 15,500W = <b>128.4%<\/b>\uff0c\u5728\u65e5\u7acb 130% \u4e0a\u9650\u4e4b\u5185\uff0c\u5224\u5b9a<b>\u5b89\u5168<\/b>\u3002\u5916\u673a APF 5.80\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c\u5236\u51b7 -5~59\u2103\u3001\u5236\u70ed -23~17\u2103\u5168\u57df\u7a33\u5b9a\u8fd0\u884c\u3002\n  <\/div>\n\n  <!-- \u76f8\u5173\u4ea7\u54c1\uff1a\u65e5\u7acb\u8212\u4eabEX\uff08\u5185\u94fe 1077\uff0c\u7f6e\u4e8e\u7a7a\u8c03\u8bb2\u89e3\u4e0b\u65b9\uff09 -->\n  <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\" title=\"\u65e5\u7acb\u8212\u4eabEX \u4e2d\u592e\u7a7a\u8c03 \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\" style=\"background:#eef2f6;\">\n        <img decoding=\"async\" class=\"lm-flip-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1-1024x768.jpg\" alt=\"\u65e5\u7acb\u8212\u4eabEX \u5916\u673a RAS-160HRNAQ\uff08\u5355\u98ce\u6247\uff09\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <div class=\"lm-flip-cap\">\u65e5\u7acb\u8212\u4eabEX \u5916\u673a<span>RAS-160HRNAQ \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd \u21bb<\/span><\/div>\n      <\/div>\n      <div class=\"lm-flip-back\"><h4>\u8212\u4eabEX \u6027\u80fd\u4e0e\u5356\u70b9<\/h4><ul><li>APF 5.80\uff0c\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548<\/li><li>\u5168\u76f4\u6d41\u53d8\u9891 + \u516d\u8109\u6ce2\u7535\u78c1\u52a0\u70ed<\/li><li>-23\u2103~17\u2103 \u4f4e\u6e29\u7a33\u5b9a\u5236\u70ed<\/li><li>\u5916\u673a\u591c\u95f4\u9759\u97f3\u518d\u964d 9dB(A)<\/li><\/ul><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u67e5\u770b\u8212\u4eab\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s3-floor\">\u4e8c\u3001\u66fc\u745e\u5fb7\u8282\u80fd\u578b\u5730\u6696\uff08\u542b\u4e2d\u592e\u8054\u52a8\u63a7\u5236\u7cfb\u7edf\uff09<\/h3>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u5206\u9879<\/th><th>\u5173\u952e\u8bbe\u5907\/\u8bf4\u660e<\/th><th>\u5408\u8ba1(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u70ed\u6e90<\/td><td>\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u53d8\u9891\u7089 L1PB24 \u00d71 + \u5ba4\u6e29\u8054\u52a8\u63a7\u5236 \u00d71\uff08\u8054\u52a8\u9505\u7089\u542f\u505c\u8282\u80fd\uff09<\/td><td>11,979<\/td><\/tr>\n      <tr><td>\u4e3b\u7ba1\u7cfb\u7edf<\/td><td>\u4f1f\u661f F-PPR \u7ea4\u7ef4\u590d\u5408\u7ba1 De32 + \u94dc\u8d28\u5206\u96c6\u6c34\u5668 6 \u8def + \u4fdd\u6e29\u7ba1 + \u9600\u95e8\u5c3e\u4ef6<\/td><td>2,921<\/td><\/tr>\n      <tr><td>\u76d8\u7ba1\u7cfb\u7edf<\/td><td>\u4f1f\u661f PE-RT \u5730\u6696\u7ba1 dn20 \u00d7404m + \u955c\u9762\u53cd\u5c04\u819c + \u8bfa\u5c14\u6324\u5851\u677f + C15 \u56de\u586b\u5c42<\/td><td>9,255<\/td><\/tr>\n      <tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u66fc\u745e\u5fb7\u5ba4\u6e29\u63a7\u5236\u5668 RT1.23i \u00d74\uff08WiFi\u8054\u52a8\uff09+ \u7535\u70ed\u6267\u884c\u5668 SEH35.23 \u00d76<\/td><td>2,072<\/td><\/tr>\n      <tr><td>\u670d\u52a1\u4fdd\u969c<\/td><td>\u9f99\u8109\u8bbe\u8ba1 + \u4f1f\u661f\u661f\u76d1\u7406 + \u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd \u4e09\u65b9 50 \u5e74\u8054\u4fdd<\/td><td>2,820<\/td><\/tr>\n      <tr><td>\u65bd\u5de5\u8d39<\/td><td>\u91c7\u6696\u7cfb\u7edf\u5b89\u88c5\u53ca\u8c03\u8bd5<\/td><td>3,326<\/td><\/tr>\n      <tr><td>\u7ba1\u7406\u8d39 + \u8fd0\u8d39<\/td><td>(\u8bbe\u5907+\u65bd\u5de5)\u00d71.5% + \u8fd0\u8d39<\/td><td>972<\/td><\/tr>\n      <tr><td colspan=\"2\"><b>\u5730\u6696\u7cfb\u7edf\u603b\u8ba1<\/b><\/td><td><b>33,344<\/b><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <!-- \u5730\u6696\u5b89\u88c5\u5b9e\u666f\u56fe -->\n  <div style=\"margin:16px 0;text-align:center;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-floor-heating-installation-03.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u5b89\u88c5\u5b9e\u666f \u00b7 \u7eff\u6eaa\u58f9\u9ed8\u8bbe\u8ba1\u5e08\u6696\u901a\u5730\u6696\u65bd\u5de5\u6848\u4f8b\" loading=\"lazy\" style=\"width:100%;max-width:680px;border-radius:12px;box-shadow:var(--shadow);\" onerror=\"this.parentElement.innerHTML='<p style=\\\"color:var(--text);opacity:.6;font-size:.8rem;\\\">\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d \u00b7 \u8bf7\u7528\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\u67e5\u770b\u5730\u6696\u5b89\u88c5\u5b9e\u666f<\/p>&#8216;&#8221;>\n    <p style=\"font-size:.8rem;color:var(--text);opacity:.7;margin-top:8px;\">\u9f99\u8109\u6696\u901a\u8282\u80fd\u578b\u5730\u6696\u5b89\u88c5\u5b9e\u666f \u00b7 \u7cbe\u5de5\u4ea4\u4ed8<\/p>\n  <\/div>\n  <!-- \u76f8\u5173\u4ea7\u54c1\uff1a\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff08\u5185\u94fe 1841\uff0c\u7f6e\u4e8e\u5730\u6696\u8bb2\u89e3\u4e0b\u65b9\uff09 -->\n  <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\" title=\"\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u7089 \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\" style=\"background:#eef2f6;\">\n        <img decoding=\"async\" class=\"lm-flip-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u58c1\u6302\u7089.jpg\" alt=\"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u7cfb\u7edf\u6b63\u9762\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <div class=\"lm-flip-cap\">\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u7089<span>L1PB24 \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd \u21bb<\/span><\/div>\n      <\/div>\n      <div class=\"lm-flip-back\"><h4>\u58c1\u6302\u7089\u6027\u80fd\u4e0e\u5356\u70b9<\/h4><ul><li>\u5206\u6bb5\u71c3\u70e7\u53d8\u9891\uff0c\u8d1f\u8377\u81ea\u9002\u5e94<\/li><li>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff0c\u4eba\u8d70\u81ea\u52a8\u964d\u8017<\/li><li>\u914d\u4f1f\u661f PE-RT \u76d8\u7ba1\u957f\u671f\u7a33\u5b9a<\/li><li>\u4e09\u65b9 50 \u5e74\u4ea7\u54c1\u8054\u4fdd<\/li><\/ul><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\">\u67e5\u770b\u58c1\u6302\u7089\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u76f8\u5173\u4ea7\u54c1\uff1a\u8282\u80fd\u578b\u5730\u6696\u7cfb\u7edf\uff08\u5185\u94fe 1976\uff09 -->\n  <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\" title=\"\u8282\u80fd\u578b\u5730\u6696\u7cfb\u7edf \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\" style=\"background:linear-gradient(135deg,#b8860b,#8a6508);\">\n        <div class=\"lm-flip-cap\">\u8282\u80fd\u578b\u5730\u6696\u7cfb\u7edf<span>\u4f1f\u661f PE-RT \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd \u21bb<\/span><\/div>\n      <\/div>\n      <div class=\"lm-flip-back\"><h4>\u8282\u80fd\u5730\u6696\u6027\u80fd\u4e0e\u5356\u70b9<\/h4><ul><li>\u955c\u9762\u53cd\u5c04\u819c + \u6324\u5851\u677f\u53cc\u4fdd\u6e29<\/li><li>C15 \u56de\u586b\u84c4\u70ed\uff0c\u8212\u9002\u5ea6\u9ad8<\/li><li>\u7ea6 3 \u5e74\u7528\u7701\u4e0b\u7684\u6c14\u8d39\u56de\u672c<\/li><li>\u4f4e\u6e29\u8f90\u5c04\uff0c\u811a\u6696\u5934\u51c9\u66f4\u5065\u5eb7<\/li><\/ul><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u67e5\u770b\u5730\u6696\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s3-fresh\">\u4e09\u3001\u65e5\u7acb\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff08178m\u00b3\/h\uff09<\/h3>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5408\u8ba1(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u65e5\u7acb<\/td><td>\u65b0\u98ce\u6362\u6c14\u673a \u4e91\u51c0\u2161\u7cfb\u5217<\/td><td>KPI-2521Q3A\/F\uff08250\/225\/200 \u4e09\u6863\u98ce\u91cf\uff09<\/td><td>1 \u53f0<\/td><td>5,500<\/td><\/tr>\n      <tr><td>\u771f\u5982<\/td><td>PE \u6ce2\u7eb9\u7ba1 + \u8f6f\u7ba1 + \u98ce\u53e3\u5957\u4ef6 + 304 \u9632\u96e8\u98ce\u7f69<\/td><td>\u00d8110\/\u00d875 \u6811\u72b6\u5e03\u7ba1<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u9f99\u8109<\/td><td>\u65b0\u98ce\u5b89\u88c5\u8c03\u8bd5 + \u6750\u6599\/\u8bbe\u8ba1\u8d39<\/td><td>\u6280\u5e08\u56e2\u961f\u6807\u51c6\u6d41\u7a0b<\/td><td>1 \u9879<\/td><td>6,000<\/td><\/tr>\n      <tr><td colspan=\"4\"><b>\u65b0\u98ce\u7cfb\u7edf\u603b\u8ba1<\/b>\uff08\u53cb\u60c5\u4ef7 9,800 \u5143\u8d77\uff09<\/td><td><b>11,500<\/b><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p class=\"lm-lead\">\u9001\u98ce\u53e3 6 \u4e2a\u3001\u6392\u98ce\u53e3 5 \u4e2a\uff0c\u5168\u70ed\u4ea4\u6362\u82af\u56de\u6536\u6392\u98ce\u80fd\u91cf\u9884\u5904\u7406\u65b0\u98ce\uff0c\u914d\u5408\u7a7a\u8c03\u5730\u6696\u4f7f\u7528\uff0c\u6362\u6c14\u4e0d\u6d6a\u8d39\u51b7\u70ed\u6e90\u3002<\/p>\n\n  <!-- \u76f8\u5173\u4ea7\u54c1\uff1a\u65e5\u7acb\u4e91\u51c0\u2161\u65b0\u98ce\uff08\u5185\u94fe 1758\uff0c\u7f6e\u4e8e\u65b0\u98ce\u8bb2\u89e3\u4e0b\u65b9\uff09 -->\n  <div class=\"lm-flip-card\" onclick=\"this.classList.toggle('flipped')\" title=\"\u65e5\u7acb\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd\">\n    <div class=\"lm-flip-inner\">\n      <div class=\"lm-flip-front\" style=\"background:#eef2f6;\">\n        <img decoding=\"async\" class=\"lm-flip-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u4e91\u51c0\u65b0\u98ce04-17.jpg\" alt=\"\u65e5\u7acb\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u673a KPI-2521Q3A\/F\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <div class=\"lm-flip-cap\">\u65e5\u7acb\u4e91\u51c0\u2161\u65b0\u98ce<span>KPI-2521Q3A\/F \u00b7 \u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd \u21bb<\/span><\/div>\n      <\/div>\n      <div class=\"lm-flip-back\"><h4>\u4e91\u51c0\u2161\u6027\u80fd\u4e0e\u5356\u70b9<\/h4><ul><li>250\/225\/200 \u4e09\u6863\u98ce\u91cf\u53ef\u8c03<\/li><li>\u5168\u70ed\u4ea4\u6362\u82af\u56de\u6536\u6392\u98ce\u80fd\u91cf<\/li><li>\u6362\u6c14\u4e0d\u6d6a\u8d39\u7a7a\u8c03\u5730\u6696\u51b7\u70ed\u6e90<\/li><li>178m\u00b3\/h \u6ee1\u8db3 94\u33a1 \u5168\u5c4b<\/li><\/ul><a class=\"lm-intlink\" href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u67e5\u770b\u65b0\u98ce\u8be6\u60c5 \u2192<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s3-sum\">\u56db\u3001\u4e09\u7cfb\u7edf\u6574\u88c5\u6253\u5305\u62a5\u4ef7<\/h3>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u7cfb\u7edf<\/th><th>\u6838\u5fc3\u914d\u7f6e<\/th><th>\u72ec\u7acb\u62a5\u4ef7(\u5143)<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u8212\u4eabEX RAS-160HRNAQ + 5 \u53f0\u5185\u673a + 5 WiFi\u7ebf\u63a7<\/td><td>50,805<\/td><\/tr>\n      <tr><td>\u66fc\u745e\u5fb7\u8282\u80fd\u578b\u5730\u6696<\/td><td>L1PB24 \u5206\u6bb5\u71c3\u70e7\u7089 + \u4e2d\u592e\u8054\u52a8 + \u4f1f\u661f\u76d8\u7ba1<\/td><td>33,344<\/td><\/tr>\n      <tr><td>\u65e5\u7acb\u4e91\u51c0\u2161\u65b0\u98ce<\/td><td>KPI-2521Q3A\/F \u5168\u70ed\u4ea4\u6362 178m\u00b3\/h<\/td><td>11,500<\/td><\/tr>\n      <tr><td><b>\u72ec\u7acb\u62a5\u4ef7\u5408\u8ba1<\/b><\/td><td>\u4e09\u7cfb\u7edf\u5206\u522b\u5355\u72ec\u8d2d\u4e70<\/td><td><b>95,649<\/b><\/td><\/tr>\n      <tr><td><b>\u6574\u88c5\u6253\u5305\u7b7e\u5355\u4ef7<\/b><\/td><td>\u7a7a\u8c03 + \u5730\u6696 + \u65b0\u98ce \u4e00\u6b21\u6027\u9501\u5b9a<\/td><td><span class=\"lm-price-final\">60,800<\/span><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"lm-callout\">\n    <b>\u6574\u88c5\u6743\u76ca\uff1a<\/b>\u4e09\u7cfb\u7edf\u4e00\u5bb6\u7edf\u7b79\u8bbe\u8ba1\u65bd\u5de5\uff0c\u6253\u5305\u7b7e\u5355 <b>60,800 \u5143<\/b>\uff0c\u8f83\u5206\u5f00\u8d2d\u4e70\u5408\u8ba1 95,649 \u5143\uff0c\u4e3a\u5d14\u8001\u5e08<b>\u76f4\u7701\u7ea6 34,800 \u5143<\/b>\u3002\u542b\u8bbe\u5907\u5b89\u88c5\u3001\u5899\u4f53\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\uff1b\u8f85\u6750\u4ee5\u5de5\u5730\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u5408\u540c\u603b\u4ef7\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4fdd\u969c ===== -->\n<section id=\"s4\">\n  <h2>S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4fdd\u969c<\/h2>\n  <h3 id=\"s4-stage\">\u65bd\u5de5\u9636\u6bb5\u8868<\/h3>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u9636\u6bb5<\/th><th>\u5185\u5bb9<\/th><th>\u9a8c\u6536\u8981\u70b9<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e00\u3001\u8fdb\u573a\u5b9a\u4f4d<\/td><td>\u4e09\u65b9\u73b0\u573a\u4ea4\u5e95\uff0c\u786e\u5b9a\u5185\u5916\u673a\/\u9505\u7089\/\u65b0\u98ce\u4e3b\u673a\u53ca\u7ba1\u7ebf\u8d70\u4f4d<\/td><td>\u51fa\u5b9a\u4f4d\u56fe\uff0c\u4e1a\u4e3b\u786e\u8ba4\u7b7e\u5b57<\/td><\/tr>\n      <tr><td>\u4e8c\u3001\u6c34\u7535\u9884\u7559<\/td><td>\u914d\u5408\u88c5\u9970\u516c\u53f8\u9884\u7559\u7535\u6e90\u3001\u71c3\u6c14\u3001\u7ed9\u6392\u6c34\u63a5\u53e3<\/td><td>\u70b9\u4f4d\u7b26\u5408\u89c4\u8303<\/td><\/tr>\n      <tr><td>\u4e09\u3001\u7ba1\u9053\u5b89\u88c5<\/td><td>\u7a7a\u8c03\u94dc\u7ba1\u3001\u5730\u6696\u76d8\u7ba1\u3001\u65b0\u98ce\u6811\u72b6\u5e03\u7ba1\u540c\u6b65\u65bd\u5de5<\/td><td>\u6253\u538b\u8bd5\u538b\u5408\u683c<\/td><\/tr>\n      <tr><td>\u56db\u3001\u9690\u853d\u9a8c\u6536<\/td><td>\u4fdd\u6e29\u3001\u540a\u67b6\u3001\u56de\u586b\u524d\u62cd\u7167\u7559\u6863 + VR \u5168\u666f<\/td><td>\u4f1f\u661f\u661f\u76d1\u7406\u7b2c\u4e09\u65b9\u9a8c\u6536<\/td><\/tr>\n      <tr><td>\u4e94\u3001\u8bbe\u5907\u5c31\u4f4d<\/td><td>\u5185\u5916\u673a\u3001\u9505\u7089\u3001\u65b0\u98ce\u673a\u5b89\u88c5\u63a5\u7ebf<\/td><td>\u7cfb\u7edf\u8054\u52a8\u8c03\u8bd5\u901a\u8fc7<\/td><\/tr>\n      <tr><td>\u516d\u3001\u7ae3\u5de5\u4ea4\u4ed8<\/td><td>\u6574\u4f53\u8c03\u8bd5 + \u4f7f\u7528\u57f9\u8bad + \u8d44\u6599\u5f52\u6863<\/td><td>\u4e09\u7cfb\u7edf\u8054\u5408\u9a8c\u6536<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3 id=\"s4-promise\">\u670d\u52a1\u627f\u8bfa<\/h3>\n  <div class=\"lm-grid\">\n    <div class=\"lm-mini\"><h4>\u8d28\u4fdd<\/h4><p>\u7a7a\u8c03\u8bbe\u5907\u8fdb\u573a 66 \u4e2a\u6708\u8d28\u4fdd\uff08\u6574\u673a 60 \u4e2a\u6708 + 6 \u4e2a\u6708\u88c5\u4fee\u671f\uff09\u3002<\/p><\/div>\n    <div class=\"lm-mini\"><h4>\u4e09\u65b9\u8054\u4fdd<\/h4><p>\u5730\u6696\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b 50 \u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae\u3002<\/p><\/div>\n    <div class=\"lm-mini\"><h4>\u7b2c\u4e09\u65b9\u76d1\u7406<\/h4><p>\u4f1f\u661f&#8221;\u661f\u76d1\u7406&#8221;\u63d0\u4f9b\u68c0\u67e5\u3001\u6253\u538b\u53ca VR \u5168\u666f\uff0c\u9690\u853d\u5de5\u7a0b\u53ef\u8ffd\u6eaf\u3002<\/p><\/div>\n    <div class=\"lm-mini\"><h4>\u4e00\u7ad9\u7edf\u7b79<\/h4><p>\u4e09\u7cfb\u7edf\u7531\u9f99\u8109\u4e00\u5bb6\u8bbe\u8ba1\u65bd\u5de5\uff0c\u8d23\u4efb\u5355\u4e00\u3001\u5bf9\u63a5\u7701\u5fc3\u3002<\/p><\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3 ===== -->\n<section id=\"s5\">\n  <h2>S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<\/h2>\n  <h3 id=\"s5-cases\">\u76f8\u5173\u6848\u4f8b\u4e0e\u6587\u7ae0<\/h3>\n  <div class=\"lm-links\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u8212\u4eabEX \u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u5730\u6696\u7cfb\u7edf\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u65e5\u7acb\u65b0\u98ce\u7cfb\u7edf \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n  <\/div>\n\n  <h3 id=\"s5-ai\">AI \u65b9\u6848\u9a8c\u8bc1\u6e05\u5355<\/h3>\n  <table class=\"lm-tbl\">\n    <thead><tr><th>\u68c0\u67e5\u9879<\/th><th>\u6838\u7b97\u7ed3\u679c<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u7a7a\u8c03\u8d85\u914d\u7387<\/td><td>19,900W \u00f7 15,500W = 128.4%<\/td><td>\u2264130% \u00b7 \u901a\u8fc7<\/td><\/tr>\n      <tr><td>\u7a7a\u8c03\u8bbe\u5907\u5408\u8ba1<\/td><td>17150+6820+6720+6440+6250+6050+1375<\/td><td>= 50,805 \u00b7 \u901a\u8fc7<\/td><\/tr>\n      <tr><td>\u5730\u6696\u8bbe\u8ba1\u70ed\u6307\u6807<\/td><td>9,400W \u00f7 94\u33a1 \u2248 100 W\/\u33a1<\/td><td>\u7b26\u5408\u89c4\u8303 \u00b7 \u901a\u8fc7<\/td><\/tr>\n      <tr><td>\u5730\u6696\u7cfb\u7edf\u5408\u8ba1<\/td><td>29047+3326+486+486+\u2026\uff08\u542b\u7ba1\u7406\u8fd0\u8d39\uff09<\/td><td>= 33,344 \u00b7 \u901a\u8fc7<\/td><\/tr>\n      <tr><td>\u65b0\u98ce\u91cf\u6821\u6838<\/td><td>178m\u00b3\/h \u2264 \u4e91\u51c0\u2161 250 \u98ce\u91cf\u6863<\/td><td>\u4f59\u91cf\u5145\u8db3 \u00b7 \u901a\u8fc7<\/td><\/tr>\n      <tr><td>\u4e09\u7cfb\u7edf\u5408\u8ba1\u5bf9\u8d26<\/td><td>50805 + 33344 + 11500 = 95,649<\/td><td>\u6253\u5305\u4ef7 60,800 \u00b7 \u4e00\u81f4<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/section>\n\n<!-- ===== \u76f8\u5173\u4ea7\u54c1\u94fe\u63a5 ===== -->\n<section id=\"products\">\n  <h2>\u76f8\u5173\u4ea7\u54c1\u4e0e\u7cfb\u7edf\u914d\u5957<\/h2>\n  <p class=\"lm-lead\">\u4e0a\u65b9\u5404\u7cfb\u7edf\u8bb2\u89e3\u5df2\u5185\u5d4c\u5bf9\u5e94\u4ea7\u54c1\u5361\u7247\uff08\u70b9\u51fb\u7ffb\u8f6c\u770b\u6027\u80fd\uff09\uff0c\u4ee5\u4e0b\u4e3a\u5b98\u7f51\u4ea7\u54c1\u9875\u76f4\u8fbe\uff1a<\/p>\n  <div class=\"lm-links\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u8212\u4eabEX \u4e2d\u592e\u7a7a\u8c03 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u65e5\u7acb\u4e91\u51c0\u2161\u65b0\u98ce \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u8282\u80fd\u578b\u5730\u6696\u7cfb\u7edf \u2014 \u9f99\u8109\u6696\u901a<\/a>\n  <\/div>\n<\/section>\n\n<!-- ===== \u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97 ===== -->\n<section id=\"showroom\">\n  <h2>\u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97<\/h2>\n  <p class=\"lm-lead\">\u9f99\u8109\u6696\u901a\u4e3a\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546\uff0c\u4ee5\u4e0b\u4e3a\u76f8\u5173\u6388\u6743\u8bc1\u4e66\uff1b\u65b9\u6848\u54a8\u8be2\u4e0e\u8bbe\u5907\u9a8c\u6536\u53ef\u81f3\u9f99\u8109\u6696\u901a\u6210\u90fd\u4e24\u5e97\u5b9e\u5730\u529e\u7406\u3002<\/p>\n\n  <h3>\u54c1\u724c\u6388\u6743\u8bc1\u4e66<\/h3>\n  <div class=\"lm-cert-grid\">\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66 2026\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743 2026<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66 2026\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500 2026<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500<\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-cert-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\u65e5\u7acb\u7279\u9080\u5b89\u88c5 2026<\/figcaption>\n    <\/figure>\n  <\/div>\n\n  <h3>\u9f99\u8109\u6696\u901a\u95e8\u5e97\u5b9e\u666f<\/h3>\n  <div class=\"lm-store-grid\">\n    <figure>\n      <div class=\"lm-store-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\n        <div class=\"lm-store-name\">\u5357\u5bcc\u68ee\u5e97<\/div>\n        <div class=\"lm-addr\">\ud83d\udccd \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/div>\n        <div class=\"lm-addr\">\u260e 13908183204\uff08\u4f59\u7231\u82f1\uff09<\/div>\n      <\/figcaption>\n    <\/figure>\n    <figure>\n      <div class=\"lm-store-img-wrap\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.parentElement.classList.add('lm-img-fail')\"><\/div>\n      <figcaption>\n        <div class=\"lm-store-name\">\u5317\u5bcc\u68ee\u5e97<\/div>\n        <div class=\"lm-addr\">\ud83d\udccd \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/div>\n        <div class=\"lm-addr\">\u260e 13908183204\uff08\u4f59\u7231\u82f1\uff09<\/div>\n      <\/figcaption>\n    <\/figure>\n  <\/div>\n  <p style=\"font-size:.8rem;color:var(--text);opacity:.7;\">\u8bf4\u660e\uff1a\u6388\u6743\u8bc1\u4e66\u4e0e\u95e8\u5e97\u5b9e\u666f\u5747\u53d6\u81ea\u9f99\u8109\u6696\u901a\u5a92\u4f53\u5e93\uff08\u5177\u6b63\u5f0f URL\uff0c\u975e\u672c\u5730\u8def\u5f84\uff09\u3002\u5982\u4e2a\u522b\u56fe\u7247\u9700\u8054\u7f51\u52a0\u8f7d\uff0c\u8bf7\u7528\u7cfb\u7edf\u6d4f\u89c8\u5668\u6253\u5f00\u672c\u9875\u67e5\u770b\u3002<\/p>\n<\/section>\n\n<!-- ===== FAQ ===== -->\n<section id=\"faq\">\n  <h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n  <div class=\"lm-faq-item\"><b>Q1\uff1a\u65e5\u7acb\u548c\u683c\u529b\u4ef7\u683c\u5dee\u4e0d\u591a\uff0c\u4e3a\u4ec0\u4e48\u63a8\u8350\u65e5\u7acb\uff1f<\/b><p>A\uff1a\u54c1\u724c\u5dee\u8ddd\u4e0d\u5728\u5236\u4e0d\u5236\u51b7\uff0c\u800c\u5728\u8212\u9002\u5ea6\u4e0e\u8282\u80fd\u6027\u3002\u540c\u4ef7\u4f4d\u4e0b\uff0c\u65e5\u7acb\u8212\u4eabEX \u91c7\u7528\u5168\u76f4\u6d41\u53d8\u9891 + \u516d\u8109\u6ce2\u7535\u78c1\u52a0\u70ed\u538b\u7f29\u673a\uff0cAPF \u8fbe 5.80\uff0c\u5185\u673a\u4f4e\u81f3 17dB(A)\uff0c\u5e76\u5177\u5907\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01\u4e0e 60\u2103\u9ad8\u6e29\u9664\u83cc\uff0c\u957f\u671f\u66f4\u7701\u7535\u3001\u66f4\u9759\u97f3\u3001\u66f4\u6d01\u51c0\u3002<\/p><\/div>\n  <div class=\"lm-faq-item\"><b>Q2\uff1a\u8282\u80fd\u578b\u5730\u6696\u6bd4\u901a\u914d\u578b\u8d35\uff0c\u591a\u4e45\u80fd\u56de\u672c\uff1f<\/b><p>A\uff1a\u8282\u80fd\u578b\u914d\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u53d8\u9891\u7089 + \u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff0c\u4eba\u8d70\u81ea\u52a8\u964d\u8d1f\u8377\u3002\u623f\u5b50\u957f\u671f\u81ea\u4f4f\u7684\u60c5\u51b5\u4e0b\uff0c\u524d\u671f\u591a\u6295\u5165\u90e8\u5206\u7ea6 3 \u5e74\u5373\u53ef\u7528\u7701\u4e0b\u7684\u6c14\u8d39\u56de\u672c\uff0c\u4e4b\u540e\u6bcf\u5e74\u90fd\u662f\u51c0\u7701\uff0c\u8d8a\u7528\u8d8a\u5212\u7b97\u3002<\/p><\/div>\n  <div class=\"lm-faq-item\"><b>Q3\uff1a\u5f00\u4e86\u7a7a\u8c03\u5730\u6696\u8fd8\u6709\u5fc5\u8981\u88c5\u65b0\u98ce\u5417\uff1f<\/b><p>A\uff1a\u975e\u5e38\u6709\u5fc5\u8981\u3002\u7a7a\u8c03\u5730\u6696\u90fd\u9700\u5173\u7a97\u4fdd\u6e29\uff0c\u957f\u671f\u5bc6\u95ed\u4f1a\u8ba9 CO\u2082 \u5347\u9ad8\u3001\u7a7a\u6c14\u53d8\u95f7\u3002\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u6362\u6c14\u65f6\u56de\u6536\u6392\u98ce\u80fd\u91cf\u9884\u5904\u7406\u65b0\u98ce\uff0c\u65e2\u4fdd\u8bc1\u7a7a\u6c14\u6e05\u65b0\uff0c\u53c8\u4e0d\u6d6a\u8d39\u82b1\u94b1\u5236\u9020\u7684\u51b7\u70ed\u6e90\u3002<\/p><\/div>\n  <div class=\"lm-faq-item\"><b>Q4\uff1a\u5916\u673a\u62d6 5 \u53f0\u5185\u673a\uff0c\u4f1a\u4e0d\u4f1a\u5e26\u4e0d\u52a8\uff1f<\/b><p>A\uff1a\u4e0d\u4f1a\u3002\u5185\u673a\u603b\u51b7\u91cf 19,900W \u00f7 \u5916\u673a 15,500W = 128.4%\uff0c\u5728\u65e5\u7acb 130% \u4e0a\u9650\u4e4b\u5185\uff0c\u5c5e\u5b89\u5168\u914d\u7f6e\u3002\u5ba2\u9910\u5385\u91c7\u7528\u53cc\u5185\u673a\u5206\u533a\u9001\u98ce\uff0c\u51b7\u70ed\u66f4\u5747\u5300\u3002<\/p><\/div>\n  <div class=\"lm-faq-item\"><b>Q5\uff1a\u4e09\u7cfb\u7edf\u6253\u5305 60,800 \u5143\u5305\u542b\u54ea\u4e9b\uff1f<\/b><p>A\uff1a\u5305\u542b\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u5168\u90e8\u8bbe\u5907\u4e0e\u5b89\u88c5\uff0c\u542b\u5899\u4f53\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\uff0c\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff1b\u8f85\u6750\u4ee5\u5de5\u5730\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\/\u7a7a\u5f00\u3001\u5f00\u7968\u53ca\u8fdc\u7a0b\u8d39\u7b49\uff08\u8be6\u89c1\u5404\u7cfb\u7edf\u62a5\u4ef7\u8bf4\u660e\uff09\u3002<\/p><\/div>\n  <div class=\"lm-faq-item\"><b>Q6\uff1a\u8d28\u4fdd\u548c\u552e\u540e\u600e\u4e48\u4fdd\u969c\uff1f<\/b><p>A\uff1a\u7a7a\u8c03\u8bbe\u5907\u8fdb\u573a 66 \u4e2a\u6708\u8d28\u4fdd\uff1b\u5730\u6696\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b 50 \u5e74\u4ea7\u54c1\u8054\u4fdd\uff1b\u9690\u853d\u5de5\u7a0b\u7531\u4f1f\u661f\u661f\u76d1\u7406\u7b2c\u4e09\u65b9\u9a8c\u6536\u5e76\u7559 VR \u5168\u666f\uff0c\u5168\u7a0b\u53ef\u8ffd\u6eaf\u3002<\/p><\/div>\n<\/section>\n\n<!-- ===== \u5ef6\u4f38\u9605\u8bfb ===== -->\n<section id=\"links\">\n  <h2>\u5ef6\u4f38\u9605\u8bfb<\/h2>\n  <div class=\"lm-links\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u65e5\u7acb\u8212\u4eabEX \u4e2d\u592e\u7a7a\u8c03 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u5730\u6696\u7cfb\u7edf\u4ecb\u7ecd \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" target=\"_blank\">\u65e5\u7acb\u65b0\u98ce\u7cfb\u7edf \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u2014 \u9f99\u8109\u6696\u901a<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2705\" target=\"_blank\">\u9f99\u8109\u6696\u901a\u65b9\u6848\u4e2d\u5fc3<\/a>\n  <\/div>\n<\/section>\n\n<!-- ===== \u9500\u552e\u987e\u95ee\u4fe1\u606f ===== -->\n<section id=\"consultant\" style=\"text-align:center;padding:32px 20px;background:linear-gradient(135deg,#1a3a5c,#2c5f8a);color:#fff;border-radius:0;margin:0;\">\n  <h2 style=\"color:#fff;border:none;margin-bottom:8px;\">\u9f99\u8109\u6696\u901a<\/h2>\n  <p style=\"font-size:15px;letter-spacing:2px;margin:0 0 16px;opacity:.92;\">\u4e13\u4e1a\u6696\u901a \u00b7 \u7cbe\u5de5\u4ea4\u4ed8 \u00b7 \u7ec8\u8eab\u670d\u52a1<\/p>\n  <div style=\"display:inline-block;text-align:left;background:rgba(255,255,255,.08);border-radius:12px;padding:20px 28px;font-size:14px;line-height:2;\">\n    <div><b style=\"color:#b8860b;\">\u9500\u552e\u987e\u95ee\uff1a<\/b>\u4f59\u7231\u82f1 \u00b7 13908183204<\/div>\n    <div><b style=\"color:#b8860b;\">\u4ece\u4e1a\u7ecf\u5386\uff1a<\/b>14 \u5e74\uff082012 \u5e74\u52a0\u5165\uff09<\/div>\n    <div><b style=\"color:#b8860b;\">\u6c9f\u901a\u95e8\u5e97\uff1a<\/b>\u5357\u5bcc\u68ee\u95e8\u5e97<\/div>\n    <div><b style=\"color:#b8860b;\">\u6c9f\u901a\u65e5\u671f\uff1a<\/b>2026 \u5e74 7 \u6708 23 \u65e5<\/div>\n  <\/div>\n<\/section>\n\n<\/div><!-- \/.lm-wrap -->\n\n<footer>\n  \u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u987e\u95ee \u4f59\u7231\u82f1\uff0813908183204\uff09 \u00b7 \u5d14\u8001\u5e08\u00b7\u7eff\u57ce\u9526\u56ed9\u680b \u4e09\u7cfb\u7edf\u65b9\u6848\u524d\u4e66 \u00b7 2026-07-21 \u00b7 <a href=\"https:\/\/longmai-nt.com\" target=\"_blank\">longmai-nt.com<\/a>\n<\/footer>\n\n<!-- \u5b50\u76ee\u5f55\u4e0b\u62c9\u5bfc\u822a JS -->\n<script>\n(function(){\n  var toggles=document.querySelectorAll('.lm-nav-toggle');\n  function closeAll(){\n    toggles.forEach(function(btn){\n      btn.setAttribute('aria-expanded','false');\n      var p=document.getElementById(btn.getAttribute('data-target'));\n      if(p)p.classList.remove('open');\n    });\n  }\n  toggles.forEach(function(btn){\n    btn.addEventListener('click',function(e){\n      e.stopPropagation();\n      var panel=document.getElementById(btn.getAttribute('data-target'));\n      var willOpen=!panel.classList.contains('open');\n      closeAll();\n      if(willOpen){panel.classList.add('open');btn.setAttribute('aria-expanded','true');}\n    });\n  });\n  document.querySelectorAll('.lm-nav-panel a').forEach(function(a){a.addEventListener('click',closeAll);});\n  document.addEventListener('click',function(e){if(!e.target.closest('.lm-nav-item'))closeAll();});\n})();\n<\/script>\n\n<!-- ===== JSON-LD \u56db\u4ef6\u5957 ===== -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@graph\":[\n    {\"@type\":\"Article\",\"headline\":\"\u5d14\u8001\u5e08\u00b7\u7eff\u57ce\u9526\u56ed9\u680b \u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u65b9\u6848\u524d\u4e66\",\"author\":{\"@type\":\"Person\",\"name\":\"\u4f59\u7231\u82f1\",\"jobTitle\":\"\u8d44\u6df1\u6696\u901a\u987e\u95ee\",\"description\":\"\u4ece\u4e1a14\u5e74\"},\"about\":[\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\",\"\u5730\u6696\u7cfb\u7edf\",\"\u65b0\u98ce\u7cfb\u7edf\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\"}},\n    {\"@type\":\"FAQPage\",\"mainEntity\":[\n      {\"@type\":\"Question\",\"name\":\"\u65e5\u7acb\u548c\u683c\u529b\u4ef7\u683c\u5dee\u4e0d\u591a\uff0c\u4e3a\u4ec0\u4e48\u63a8\u8350\u65e5\u7acb\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u540c\u4ef7\u4f4d\u4e0b\u65e5\u7acb\u8212\u4eabEX\u91c7\u7528\u5168\u76f4\u6d41\u53d8\u9891\u52a0\u516d\u8109\u6ce2\u7535\u78c1\u52a0\u70ed\u538b\u7f29\u673a\uff0cAPF\u8fbe5.80\uff0c\u5185\u673a\u4f4e\u81f317dB(A)\uff0c\u5177\u5907\u81ea\u6e05\u6d01\u4e0e\u9ad8\u6e29\u9664\u83cc\uff0c\u957f\u671f\u66f4\u7701\u7535\u3001\u66f4\u9759\u97f3\u3001\u66f4\u6d01\u51c0\u3002\"}},\n      {\"@type\":\"Question\",\"name\":\"\u8282\u80fd\u578b\u5730\u6696\u591a\u4e45\u80fd\u56de\u672c\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8282\u80fd\u578b\u914d\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u53d8\u9891\u7089\u52a0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff0c\u957f\u671f\u81ea\u4f4f\u7ea63\u5e74\u5373\u53ef\u7528\u7701\u4e0b\u7684\u6c14\u8d39\u56de\u672c\uff0c\u4e4b\u540e\u6bcf\u5e74\u51c0\u7701\u3002\"}},\n      {\"@type\":\"Question\",\"name\":\"\u5f00\u4e86\u7a7a\u8c03\u5730\u6696\u8fd8\u6709\u5fc5\u8981\u88c5\u65b0\u98ce\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5f88\u6709\u5fc5\u8981\uff0c\u4e91\u51c0\u2161\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u6362\u6c14\u65f6\u56de\u6536\u6392\u98ce\u80fd\u91cf\u9884\u5904\u7406\u65b0\u98ce\uff0c\u65e2\u4fdd\u8bc1\u7a7a\u6c14\u6e05\u65b0\u53c8\u4e0d\u6d6a\u8d39\u51b7\u70ed\u6e90\u3002\"}},\n      {\"@type\":\"Question\",\"name\":\"\u5916\u673a\u62d65\u53f0\u5185\u673a\u4f1a\u4e0d\u4f1a\u5e26\u4e0d\u52a8\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5185\u673a\u603b\u51b7\u91cf19900W\u9664\u4ee5\u5916\u673a15500W\u7b49\u4e8e128.4%\uff0c\u5728\u65e5\u7acb130%\u4e0a\u9650\u4e4b\u5185\uff0c\u5c5e\u5b89\u5168\u914d\u7f6e\u3002\"}},\n      {\"@type\":\"Question\",\"name\":\"\u4e09\u7cfb\u7edf\u6253\u530560800\u5143\u5305\u542b\u54ea\u4e9b\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5305\u542b\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u5168\u90e8\u8bbe\u5907\u4e0e\u5b89\u88c5\uff0c\u542b\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\uff0c\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\u3002\"}}\n    ]},\n    {\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9f99\u8109\u6696\u901a\",\"item\":\"https:\/\/longmai-nt.com\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65b9\u6848\u4e2d\u5fc3\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=2705\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u5d14\u8001\u5e08\u00b7\u7eff\u57ce\u9526\u56ed \u4e09\u7cfb\u7edf\u65b9\u6848\u524d\u4e66\"}]},\n    {\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\/\/longmai-nt.com\",\"telephone\":\"13908183204\"}\n  ]\n}\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce \u4e09\u7cfb\u7edf\u65b9 [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-8475","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd 94\u33a1\u56db\u5ba4\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94 + \u66fc\u745e\u5fb7\u5730\u6696 + \u65e5\u7acb\u65b0\u98ce\u5168\u5957\u65b9\u6848<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u7eff\u57ce\u9526\u56ed 94\u33a1\u56db\u5ba4\u4e09\u6052\u65b9\u6848\uff0c\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8054\u52a8\u5730\u6696 + \u65e5\u7acb\u5168\u70ed\u65b0\u98ce\uff0c\u6574\u88c5\u6253\u5305\u4ef7 60800 \u5143\uff0c\u5bf9\u6bd4\u65e5\u7acb\u683c\u529b\u3001\u901a\u914d \/ \u8282\u80fd\u5730\u6696\u5dee\u5f02\uff0c\u542b\u5b8c\u6574\u8d1f\u8377\u6d4b\u7b97\u3001\u6807\u51c6\u5316\u65bd\u5de5\u300150 \u5e74\u5730\u6696\u8054\u4fdd\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u95e8\u5e97\uff0c\u4e00\u7ad9\u5f0f\u51b7\u6696\u65b0\u98ce\u8bbe\u8ba1\u5b89\u88c5\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=8475\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd 94\u33a1\u56db\u5ba4\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94 + \u66fc\u745e\u5fb7\u5730\u6696 + \u65e5\u7acb\u65b0\u98ce\u5168\u5957\u65b9\u6848\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u7eff\u57ce\u9526\u56ed 94\u33a1\u56db\u5ba4\u4e09\u6052\u65b9\u6848\uff0c\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8054\u52a8\u5730\u6696 + \u65e5\u7acb\u5168\u70ed\u65b0\u98ce\uff0c\u6574\u88c5\u6253\u5305\u4ef7 60800 \u5143\uff0c\u5bf9\u6bd4\u65e5\u7acb\u683c\u529b\u3001\u901a\u914d \/ \u8282\u80fd\u5730\u6696\u5dee\u5f02\uff0c\u542b\u5b8c\u6574\u8d1f\u8377\u6d4b\u7b97\u3001\u6807\u51c6\u5316\u65bd\u5de5\u300150 \u5e74\u5730\u6696\u8054\u4fdd\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u95e8\u5e97\uff0c\u4e00\u7ad9\u5f0f\u51b7\u6696\u65b0\u98ce\u8bbe\u8ba1\u5b89\u88c5\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=8475\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-26T05:44:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475\",\"name\":\"\u6210\u90fd 94\u33a1\u56db\u5ba4\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94 + \u66fc\u745e\u5fb7\u5730\u6696 + \u65e5\u7acb\u65b0\u98ce\u5168\u5957\u65b9\u6848\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"datePublished\":\"2026-07-26T05:38:13+00:00\",\"dateModified\":\"2026-07-26T05:44:10+00:00\",\"description\":\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u7eff\u57ce\u9526\u56ed 94\u33a1\u56db\u5ba4\u4e09\u6052\u65b9\u6848\uff0c\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8054\u52a8\u5730\u6696 + \u65e5\u7acb\u5168\u70ed\u65b0\u98ce\uff0c\u6574\u88c5\u6253\u5305\u4ef7 60800 \u5143\uff0c\u5bf9\u6bd4\u65e5\u7acb\u683c\u529b\u3001\u901a\u914d \\\/ \u8282\u80fd\u5730\u6696\u5dee\u5f02\uff0c\u542b\u5b8c\u6574\u8d1f\u8377\u6d4b\u7b97\u3001\u6807\u51c6\u5316\u65bd\u5de5\u300150 \u5e74\u5730\u6696\u8054\u4fdd\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u95e8\u5e97\uff0c\u4e00\u7ad9\u5f0f\u51b7\u6696\u65b0\u98ce\u8bbe\u8ba1\u5b89\u88c5\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"width\":1754,\"height\":1240},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=8475#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5d14\u8001\u5e08\u7eff\u57ce\u9526\u56ed\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u65b9\u6848\u524d\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd 94\u33a1\u56db\u5ba4\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94 + \u66fc\u745e\u5fb7\u5730\u6696 + \u65e5\u7acb\u65b0\u98ce\u5168\u5957\u65b9\u6848","description":"\u6210\u90fd\u9f99\u8109\u6696\u901a\u7eff\u57ce\u9526\u56ed 94\u33a1\u56db\u5ba4\u4e09\u6052\u65b9\u6848\uff0c\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8054\u52a8\u5730\u6696 + \u65e5\u7acb\u5168\u70ed\u65b0\u98ce\uff0c\u6574\u88c5\u6253\u5305\u4ef7 60800 \u5143\uff0c\u5bf9\u6bd4\u65e5\u7acb\u683c\u529b\u3001\u901a\u914d \/ \u8282\u80fd\u5730\u6696\u5dee\u5f02\uff0c\u542b\u5b8c\u6574\u8d1f\u8377\u6d4b\u7b97\u3001\u6807\u51c6\u5316\u65bd\u5de5\u300150 \u5e74\u5730\u6696\u8054\u4fdd\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u95e8\u5e97\uff0c\u4e00\u7ad9\u5f0f\u51b7\u6696\u65b0\u98ce\u8bbe\u8ba1\u5b89\u88c5\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=8475","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd 94\u33a1\u56db\u5ba4\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94 + \u66fc\u745e\u5fb7\u5730\u6696 + \u65e5\u7acb\u65b0\u98ce\u5168\u5957\u65b9\u6848","og_description":"\u6210\u90fd\u9f99\u8109\u6696\u901a\u7eff\u57ce\u9526\u56ed 94\u33a1\u56db\u5ba4\u4e09\u6052\u65b9\u6848\uff0c\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8054\u52a8\u5730\u6696 + \u65e5\u7acb\u5168\u70ed\u65b0\u98ce\uff0c\u6574\u88c5\u6253\u5305\u4ef7 60800 \u5143\uff0c\u5bf9\u6bd4\u65e5\u7acb\u683c\u529b\u3001\u901a\u914d \/ \u8282\u80fd\u5730\u6696\u5dee\u5f02\uff0c\u542b\u5b8c\u6574\u8d1f\u8377\u6d4b\u7b97\u3001\u6807\u51c6\u5316\u65bd\u5de5\u300150 \u5e74\u5730\u6696\u8054\u4fdd\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u95e8\u5e97\uff0c\u4e00\u7ad9\u5f0f\u51b7\u6696\u65b0\u98ce\u8bbe\u8ba1\u5b89\u88c5\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=8475","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-07-26T05:44:10+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"7 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=8475","url":"https:\/\/longmai-nt.com\/?page_id=8475","name":"\u6210\u90fd 94\u33a1\u56db\u5ba4\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94 + \u66fc\u745e\u5fb7\u5730\u6696 + \u65e5\u7acb\u65b0\u98ce\u5168\u5957\u65b9\u6848","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=8475#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=8475#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","datePublished":"2026-07-26T05:38:13+00:00","dateModified":"2026-07-26T05:44:10+00:00","description":"\u6210\u90fd\u9f99\u8109\u6696\u901a\u7eff\u57ce\u9526\u56ed 94\u33a1\u56db\u5ba4\u4e09\u6052\u65b9\u6848\uff0c\u65e5\u7acb\u8212\u4eab EX \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u8054\u52a8\u5730\u6696 + \u65e5\u7acb\u5168\u70ed\u65b0\u98ce\uff0c\u6574\u88c5\u6253\u5305\u4ef7 60800 \u5143\uff0c\u5bf9\u6bd4\u65e5\u7acb\u683c\u529b\u3001\u901a\u914d \/ \u8282\u80fd\u5730\u6696\u5dee\u5f02\uff0c\u542b\u5b8c\u6574\u8d1f\u8377\u6d4b\u7b97\u3001\u6807\u51c6\u5316\u65bd\u5de5\u300150 \u5e74\u5730\u6696\u8054\u4fdd\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u95e8\u5e97\uff0c\u4e00\u7ad9\u5f0f\u51b7\u6696\u65b0\u98ce\u8bbe\u8ba1\u5b89\u88c5\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=8475#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=8475"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=8475#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","width":1754,"height":1240},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=8475#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5d14\u8001\u5e08\u7eff\u57ce\u9526\u56ed\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u65b9\u6848\u524d\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/8475","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8475"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/8475\/revisions"}],"predecessor-version":[{"id":8476,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/8475\/revisions\/8476"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8475"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}