{"id":886,"date":"2026-05-17T15:40:23","date_gmt":"2026-05-17T07:40:23","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=886"},"modified":"2026-05-29T15:08:11","modified_gmt":"2026-05-29T07:08:11","slug":"%e6%8c%87%e4%bb%a44%ef%bc%9a%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a%c2%b7%e4%bc%9a%e5%91%98%e5%88%b6%e4%b8%8e10%e5%b9%b4%e8%83%bd%e6%ba%90%e4%bf%9d%e9%9a%9c%e8%ae%a1%e5%88%92%e6%8c%87%e4%bb%a4","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=886","title":{"rendered":"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">DS\u6267\u884c\u89c4\u5219 V2.0<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl401\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e00\u3001\u6307\u4ee4\u76ee\u6807<\/a><\/li>\n\n\n\n<li><a href=\"#zl402\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u3001\u9002\u7528\u573a\u666f<\/a><\/li>\n\n\n\n<li><a href=\"#zl403\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e09\u3001\u5b89\u5168\u9ed8\u8ba4\u503c<\/a><\/li>\n\n\n\n<li><a href=\"#zl404\" target=\"_blank\" rel=\"noreferrer noopener\">\u56db\u3001\u6838\u5fc3\u89c4\u5219<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl4041\" target=\"_blank\" rel=\"noreferrer noopener\">4.1 \u5206\u7ec4\u89c4\u5219<\/a><\/li>\n\n\n\n<li><a href=\"#zl4042\" target=\"_blank\" rel=\"noreferrer noopener\">4.2 \u4f1a\u5458\u5236\u89c4\u5219<\/a><\/li>\n\n\n\n<li><a href=\"#zl4043\" target=\"_blank\" rel=\"noreferrer noopener\">4.3 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u89c4\u5219<\/a><\/li>\n\n\n\n<li><a href=\"#zl4044\" target=\"_blank\" rel=\"noreferrer noopener\">4.4 \u6570\u636e\u91c7\u96c6\u89c4\u5219<\/a><\/li>\n\n\n\n<li><a href=\"#zl4045\" target=\"_blank\" rel=\"noreferrer noopener\">4.5 \u6743\u76ca\u5206\u5c42<\/a><\/li>\n\n\n\n<li><a href=\"#zl4046\" target=\"_blank\" rel=\"noreferrer noopener\">4.6 \u8131\u654f\u4e0e\u9690\u79c1<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#zl405\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e94\u3001\u6267\u884c\u6b65\u9aa4<\/a><\/li>\n\n\n\n<li><a href=\"#zl406\" target=\"_blank\" rel=\"noreferrer noopener\">\u516d\u3001\u8f93\u51fa\u7269\u683c\u5f0f<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl4061\" target=\"_blank\" rel=\"noreferrer noopener\">6.1 \u677f\u5757\u4e09\u62a5\u4ef7\u4e2d\u7684\u4f1a\u5458\u6743\u76ca\u5361\u7247<\/a><\/li>\n\n\n\n<li><a href=\"#zl4062\" target=\"_blank\" rel=\"noreferrer noopener\">6.2 \u677f\u5757\u56db\u6863\u6848\u4e2d\u768410\u5e74\u80fd\u8017\u8ddf\u8e2a\u6a21\u677f<\/a><\/li>\n\n\n\n<li><a href=\"#zl4063\" target=\"_blank\" rel=\"noreferrer noopener\">6.3 \u5206\u7ec4\u786e\u8ba4\u8f93\u51fa\u683c\u5f0f<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#zl407\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e03\u3001\u9a8c\u8bc1\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl408\" target=\"_blank\" rel=\"noreferrer noopener\">\u516b\u3001\u7981\u6b62\u884c\u4e3a<\/a><\/li>\n\n\n\n<li><a href=\"#zl409\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e5d\u3001\u5e38\u89c1\u9519\u8bef<\/a><\/li>\n\n\n\n<li><a href=\"#zl410\" target=\"_blank\" rel=\"noreferrer noopener\">\u5341\u3001\u5173\u8054\u77e5\u8bc6\u5e93<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"zl401\" class=\"wp-block-heading\">\u4e00\u3001\u6307\u4ee4\u76ee\u6807<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8ba9DS\u5728\u751f\u6210\u65b9\u6848\u4e66\u548c\u5ba2\u6237\u6863\u6848\u65f6\uff0c\u81ea\u52a8\u5d4c\u5165\u4f1a\u5458\u6743\u76ca\u300110\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u3001\u5206\u7ec4\u4fe1\u606f\u3001\u80fd\u8017\u8ddf\u8e2a\u6a21\u677f\uff0c\u65e0\u9700\u9500\u552e\u6216\u65b9\u6848\u987e\u95ee\u4e8c\u6b21\u8865\u5145\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl402\" class=\"wp-block-heading\">\u4e8c\u3001\u9002\u7528\u573a\u666f<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">DS\u52a8\u4f5c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e6\u53d1\u6761\u4ef6<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u677f\u5757\u4e09\u00b7\u65b9\u6848\u62a5\u4ef7<\/td><td>\u8f93\u51fa\u4f1a\u5458\u6743\u76ca\u5361\u7247 + 10\u5e74\u8ba1\u5212\u7b80\u4ecb<\/td><td>\u4efb\u4f55\u62a5\u4ef7\u65b9\u6848<\/td><\/tr><tr><td>\u677f\u5757\u4e09\u00b7\u7b7e\u7ea6\u786e\u8ba4<\/td><td>\u8f93\u51fa\u5206\u7ec4\u786e\u8ba4\u6587\u672c<\/td><td>\u5ba2\u6237\u786e\u5b9a\u5206\u7ec4\u540e<\/td><\/tr><tr><td>\u677f\u5757\u56db\u00b7\u6863\u6848\u4eea\u8868\u76d8<\/td><td>\u8f93\u51fa10\u5e74\u80fd\u8017\u8ddf\u8e2a\u6a21\u677f\uff08\u542b\u6570\u636e\u57fa\u51c6\u8868\uff09<\/td><td>\u65b0\u5efa\u5ba2\u6237\u6863\u6848\u65f6<\/td><\/tr><tr><td>\u5ba2\u6237\u8be2\u95ee\u4f1a\u5458\/10\u5e74\u8ba1\u5212<\/td><td>\u6309\u672c\u6307\u4ee4\u89c4\u5219\u56de\u7b54<\/td><td>\u5ba2\u6237\u4e3b\u52a8\u63d0\u95ee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl403\" class=\"wp-block-heading\">\u4e09\u3001\u5b89\u5168\u9ed8\u8ba4\u503c<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u5206\u7ec4\u771f\u5b9e<\/strong>\uff1a\u5ba2\u6237\u9009A\u7ec4\u5c31\u6309A\u7ec4\u89c4\u5219\uff0c\u9009B\u7ec4\u5c31\u6309B\u7ec4\u89c4\u5219\uff0cDS\u4e0d\u5f97\u64c5\u81ea\u6539\u5206\u7ec4<\/li>\n\n\n\n<li><strong>\u6743\u76ca\u4e0d\u865a\u6784<\/strong>\uff1a\u8f93\u51fa\u6743\u76ca\u65f6\u4e25\u683c\u6309\u672c\u6307\u4ee4\uff0c\u4e0d\u5f97\u81ea\u884c\u6dfb\u52a0\u6216\u5220\u51cf\u6761\u6b3e<\/li>\n\n\n\n<li><strong>\u6570\u636e\u9690\u79c1<\/strong>\uff1a\u6863\u6848\u4e2d\u5ba2\u6237\u59d3\u540d\u3001\u5177\u4f53\u5730\u5740\u3001\u54c1\u724c\u914d\u7f6e\u4e0d\u5bf9\u5916\u516c\u5f00\uff0c\u8131\u654f\u7f16\u7801\u89c4\u5219\u89c1\u6838\u5fc3\u89c4\u5219<\/li>\n\n\n\n<li><strong>\u4e0d\u5f3a\u5236B\u7ec4<\/strong>\uff1aA\u7ec4\u5ba2\u6237\u540c\u6837\u4eab\u53d7\u8ddf\u8e2a\u670d\u52a1\uff0cDS\u4e0d\u5f97\u6697\u793aA\u7ec4&#8221;\u5dee&#8221;<\/li>\n\n\n\n<li><strong>\u4e24\u8054\u4f9b\u9ed8\u8ba4B\u7ec4<\/strong>\uff1a\u4e24\u8054\u4f9b\u5ba2\u6237\u7cfb\u7edf\u8bbe\u8ba1\u4f9d\u8d56\u9ad8\uff0c\u5fc5\u987bB\u7ec4\uff0c\u4e0d\u53ef\u9009A\u7ec4<\/li>\n\n\n\n<li><strong>\u4ef7\u683c\u900f\u660e<\/strong>\uff1a\u4f1a\u5458\u5e74\u8d39199\u5143\u3001\u514d5\u5e74\u6761\u4ef6\u3001\u9000\u6b3e\u89c4\u5219\uff0c\u5fc5\u987b\u5982\u5b9e\u8f93\u51fa<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl404\" class=\"wp-block-heading\">\u56db\u3001\u6838\u5fc3\u89c4\u5219<\/h2>\n\n\n\n<h3 id=\"zl4041\" class=\"wp-block-heading\">4.1 \u5206\u7ec4\u89c4\u5219<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u5206\u7ec4\u5b9a\u4e49<\/h4>\n\n\n\n<pre class=\"wp-block-preformatted\">A\u7ec4\uff08\u5bf9\u7167\u7ec4\uff09\u2014 \u5ba2\u6237\u90e8\u5206\u8ba4\u53ef\u9f99\u8109\u8bbe\u8ba1\n\u251c\u2500\u2500 A-A\uff1a\u53ea\u65bd\u5de5\uff0c\u7cfb\u7edf\u8bbe\u8ba1\u6309\u5ba2\u6237\u60f3\u6cd5\n\u2502   \u4f8b\uff1a\u5ba2\u6237\u8ba4\u51c6\u67d0\u9505\u7089\u54c1\u724c\uff0c\u575a\u6301\u81ea\u5df1\u7684\u914d\u7f6e\n\u2514\u2500\u2500 A-B\uff1a\u90e8\u5206\u91c7\u7eb3\u9f99\u8109\u8bbe\u8ba1\uff0c\u4f46\u6574\u4f53\u65b9\u6848\u975e\u9f99\u8109\u5168\u6848\n    \u4f8b\uff1a\u9505\u7089\u9009\u9f99\u8109\u63a8\u8350\u7684\uff0c\u4f46\u7cfb\u7edf\u575a\u6301\u7528\u81ea\u5df1\u7684\u65b9\u6848\n\nB\u7ec4\uff08\u5b9e\u9a8c\u7ec4\uff09\u2014 \u5ba2\u6237\u5b8c\u5168\u8ba4\u53ef\u9f99\u8109\u7cfb\u7edf\u8bbe\u8ba1\n\u251c\u2500\u2500 B-A\uff1a\u8ba4\u53ef\u8bbe\u8ba1\u4f46\u6709\u6240\u4fdd\u7559\n\u2502   \u4f8b\uff1a\u4e24\u8054\u4f9b\u5ba2\u6237\u8ba4\u53ef\u8bbe\u8ba1\u7406\u5ff5\u4f46\u575a\u6301\u52a0\u7f13\u51b2\u6c34\u7bb1\uff08\u8fc7\u6e21\u65b9\u6848\uff09\n\u2514\u2500\u2500 B-B\uff1a\u5b8c\u5168\u6309\u9f99\u8109\u63a8\u8350\u65b9\u6848\uff0c\u4e0d\u505a\u4efb\u4f55\u6539\u52a8\n    \u4f8b\uff1a\u4e24\u8054\u4f9b\u4e00\u6b21\u7cfb\u7edf\u65e0\u7f13\u51b2\u6c34\u7bb1\uff1b\u9505\u7089\u5730\u6696\u9009\u51b7\u51dd\u7089+\u8054\u52a8\u63a7\u5236\n<\/pre>\n\n\n\n<h4 class=\"wp-block-heading\">\u5206\u7ec4\u5224\u65ad<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u60c5\u51b5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5206\u7ec4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5224\u65ad\u4f9d\u636e<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4e24\u8054\u4f9b\uff08\u5929\u6c1f\u5730\u6c34\/\u6c34\u5885\u9002\uff09<\/td><td><strong>\u5f3a\u5236B\u7ec4<\/strong><\/td><td>\u7cfb\u7edf\u5bf9\u8bbe\u8ba1\u4f9d\u8d56\u6781\u9ad8\uff0c\u4e0d\u8ba4\u53ef\u5c31\u88c5\u4e0d\u4e86<\/td><\/tr><tr><td>\u5ba2\u6237\u6307\u5b9a\u9505\u7089\u54c1\u724c\u3001\u62d2\u7edd\u9f99\u8109\u63a8\u8350<\/td><td>A-A<\/td><td>\u81ea\u9009\u54c1\u724c<\/td><\/tr><tr><td>\u5ba2\u6237\u63a5\u53d7\u9f99\u8109\u8bbe\u8ba1\u4f46\u4ecd\u6709\u4fdd\u7559<\/td><td>A-B \u6216 B-A<\/td><td>\u770b\u4fdd\u7559\u7a0b\u5ea6<\/td><\/tr><tr><td>\u5ba2\u6237\u5b8c\u5168\u4fe1\u4efb\u3001\u4e0d\u5e72\u9884\u8bbe\u8ba1<\/td><td>B-B<\/td><td>\u5168\u6848<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e24\u8054\u4f9b\u5f3a\u5236B\u7ec4\u8bf4\u660e<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u5728\u65b9\u6848\u4e2d\u5fc5\u987b\u6ce8\u660e\uff1a<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4e24\u8054\u4f9b\u7cfb\u7edf\u5bf9\u8bbe\u8ba1\u4f9d\u8d56\u6781\u9ad8\u3002\u4e0d\u8ba4\u53ef\u9f99\u8109\u7684\u7cfb\u7edf\u8bbe\u8ba1\uff0c\u7cfb\u7edf\u65e0\u6cd5\u53d1\u6325\u5e94\u6709\u6027\u80fd\u3002\u8fd9\u4e0d\u662f\u5f3a\u5236\uff0c\u662f\u5ba2\u89c2\u89c4\u5f8b\u3002\u56e0\u6b64\u4e24\u8054\u4f9b\u5ba2\u6237\u5fc5\u987b\u9009B\u7ec4\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 id=\"zl4042\" class=\"wp-block-heading\">4.2 \u4f1a\u5458\u5236\u89c4\u5219<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u5219\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u5e74\u4f1a\u8d39<\/td><td>199\u5143\/\u5e74<\/td><\/tr><tr><td>\u9996\u5e74\u62b5\u6263<\/td><td>\u7b7e\u7ea6\u6696\u901a\u91d1\u989d1000\u5143\u76f4\u63a5\u62b5\u6263\u9996\u5e74\uff0c\u5373\u9996\u5e74\u5b9e\u4ed80\u5143<\/td><\/tr><tr><td>5\u5e74\u514d\u5355<\/td><td>\u6696\u901a\u91d1\u989d\u53ef\u8986\u76d6\u524d5\u5e74\uff08199\u00d75=995\u5143\uff09\uff0c\u8fd8\u52695\u5143\u62b5\u8bbe\u5907\u6b3e<\/td><\/tr><tr><td>\u81ea\u52a8\u7eed\u671f<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u524d15\u5929\u6536\u53d6\u4e0b\u5e74\u4f1a\u8d39<\/td><\/tr><tr><td>\u968f\u65f6\u9000\u6b3e<\/td><td>\u63091\u5143\/\u5929\u6807\u51c6\u9000\u8fd8\u4f1a\u8d39\u4f59\u989d<\/td><\/tr><tr><td>\u521d\u59cb\u72b6\u6001<\/td><td>\u7b7e\u7ea6\u65e5\u8d776\u4e2a\u6708\u4e3a\u5f85\u6fc0\u6d3b\uff08\u8bd5\u7528\u671f\uff09\uff0c\u514d\u8d39\u4eab\u53d7\u57fa\u672c\u6743\u76ca<\/td><\/tr><tr><td>\u4e3b\u52a8\u6fc0\u6d3b<\/td><td>6\u4e2a\u6708\u5185\u4e3b\u52a8\u6fc0\u6d3b\u53ef\u514d\u5f53\u5e74\u4f1a\u8d39<\/td><\/tr><tr><td>\u81ea\u52a8\u6fc0\u6d3b<\/td><td>6\u4e2a\u6708\u540e\u81ea\u52a8\u6fc0\u6d3b\uff0c\u5f00\u59cb\u8ba1\u7b97\u4f1a\u8d39<\/td><\/tr><tr><td>\u6fc0\u6d3b\u540e\u6743\u76ca<\/td><td>\u5ef6\u4fdd\u81f310\u5e74\u3001\u670d\u52a15-8\u6298\u3001\u514d\u8d39\u4e0a\u95e8\u3001\u4f18\u5148\u54cd\u5e94\u3001\u5e74\u5ea6\u80fd\u8017\u62a5\u544a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"zl4043\" class=\"wp-block-heading\">4.3 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u89c4\u5219<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u56db\u4e2a\u8def\u6807<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9636\u6bb5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ea4\u4ed8\u7269<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u57fa\u51c6\u5efa\u7acb\u671f<\/td><td>\u7b2c1\u5e74<\/td><td>\u300a\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848\u300b\u2014 \u8bbe\u8ba1\u8d1f\u8377\u3001\u5b9e\u6d4b\u80fd\u6548\u6bd4\u3001\u5173\u952e\u90e8\u4ef6\u6570\u636e<\/td><\/tr><tr><td>\u6548\u679c\u9a8c\u8bc1\u671f<\/td><td>\u7b2c3\u5e74<\/td><td>\u300a3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a\u300b\u2014 \u4e0e\u540c\u7c7b\u6237\u578b\u521d\u6b65\u5bf9\u6bd4<\/td><\/tr><tr><td>\u6df1\u5ea6\u89e3\u6790\u671f<\/td><td>\u7b2c5\u5e74<\/td><td>\u300a\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\u300b\u2014 \u90e8\u4ef6\u635f\u8017\u8bc4\u4f30\u3001\u80fd\u6548\u8870\u51cf\u5206\u6790<\/td><\/tr><tr><td>\u627f\u8bfa\u5151\u73b0\u671f<\/td><td>\u7b2c10\u5e74<\/td><td>\u300a10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u300b\u2014 \u9a8c\u8bc1\u8bbe\u8ba1\u627f\u8bfa<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u516d\u7ef4\u5ea6\u8ddf\u8e2a<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8ddf\u8e2a\u5185\u5bb9<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8fd0\u884c\u8d39<\/td><td>\u6bcf\u5e74\u5b9e\u9645\u71c3\u6c14\u8d39\/\u7535\u8d39<\/td><\/tr><tr><td>\u7ef4\u62a4\u8d39<\/td><td>\u51fa\u8fc7\u51e0\u6b21\u6545\u969c\u3001\u4fee\u4e86\u591a\u5c11\u94b1<\/td><\/tr><tr><td>\u4f7f\u7528\u5bff\u547d<\/td><td>\u9505\u7089\/\u4e3b\u673a\u3001\u63a7\u5236\u7cfb\u7edf\u3001\u7ba1\u9053\u7684\u5b9e\u9645\u4f7f\u7528\u5e74\u9650<\/td><\/tr><tr><td>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/td><td>\u6709\u6ca1\u6709\u9891\u7e41\u542f\u505c\u3001\u51b7\u70ed\u4e0d\u5747<\/td><\/tr><tr><td>\u8212\u9002\u5ea6<\/td><td>\u51ac\u5929\u80fd\u4e0d\u80fd\u70ed\u8d77\u6765\u3001\u590f\u5929\u4f1a\u4e0d\u4f1a\u95f7<\/td><\/tr><tr><td>\u521d\u6295\u8d44<\/td><td>\u524d\u671f\u82b1\u4e86\u591a\u5c11\u94b1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u627f\u8bfa\u4e00\uff1a\u6bcf\u5e74\u80fd\u8017\u5206\u6790\u4e0e\u4f18\u5316\u5efa\u8bae<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\uff0c\u63d0\u4f9b\u80fd\u8017\u5206\u6790\u62a5\u544a\uff0c\u5305\u542b\uff1a\u5f53\u5e74\u5b9e\u9645\u7528\u6c14\u91cf\u53ca\u8d39\u7528\u3001\u540c\u6237\u578b\u540c\u914d\u7f6e\u5bf9\u6807\u6570\u636e\u3001\u8282\u80fd\u4f18\u5316\u5efa\u8bae\u3002\u5982\u7cfb\u7edf\u8fd0\u884c\u8d39\u7528\u663e\u8457\u9ad8\u4e8e\u5408\u7406\u8303\u56f4\uff0c\u4e3b\u52a8\u4e0a\u95e8\u6392\u67e5\u539f\u56e0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u627f\u8bfa\u4e8c\uff1a\u514d\u8d39\u4f18\u5316\u65b9\u6848<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u6392\u67e5\u53d1\u73b0\u7cfb\u7edf\u5b58\u5728\u53ef\u4f18\u5316\u73af\u8282\uff08\u7ba1\u8def\u6c34\u529b\u5e73\u8861\u5fae\u8c03\u3001\u6e29\u63a7\u903b\u8f91\u5347\u7ea7\u3001\u8bbe\u5907\u53c2\u6570\u8c03\u6574\uff09\uff0c\u514d\u8d39\u63d0\u4f9b\u4f18\u5316\u65b9\u6848\u5e76\u534f\u52a9\u5b9e\u65bd\u3002\u5982\u5f02\u5e38\u539f\u56e0\u4e3a\u7cfb\u7edf\u8bbe\u8ba1\u6216\u65bd\u5de5\u7f3a\u9677\uff0c\u514d\u8d39\u63d0\u4f9b\u7cfb\u7edf\u4f18\u5316\u6539\u9020\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u627f\u8bfa\u4e09\uff1a10\u5e74\u8ddf\u8e2a\u627f\u8bfa<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u6863\u6848\u7b7e\u7f72\u65e5\u671f\u4e3a\u8d77\u70b9\uff0c\u63d0\u4f9b10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u3002\u5730\u6696\u76d8\u7ba1\u7531\u4f1f\u661f\u5382\u5bb6\u8d28\u4fdd50\u5e74\uff0c\u5206\u96c6\u6c34\u5668\u8bbe\u8ba1\u5bff\u547d20\u5e74\u4ee5\u4e0a\uff0c\u4e3b\u7ba1\u9053\u5bff\u547d50\u5e74\u4ee5\u4e0a\u3002\u9505\u7089\u4e3a\u56fd\u5bb6\u5f3a\u5236\u62a5\u5e9f\u8bbe\u5907\uff08\u62a5\u5e9f\u671f8\u5e74\uff09\uff0c\u7b2c9\u5e74\u4e3b\u52a8\u63d0\u9192\u66f4\u6362\u8bbe\u5907\uff0c\u66f4\u6362\u540e\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u81ea\u52a8\u5ef6\u7eed\uff0c\u8ddf\u8e2a\u5468\u671f\u91cd\u65b0\u8ba1\u7b97\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u627f\u8bfa\u56db\uff1a20\u5e74\u670d\u52a1\u4fdd\u969c<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10\u5e74\u8ddf\u8e2a\u671f\u6ee1\u540e\uff0c\u7ee7\u7eed\u63d0\u4f9b\u6301\u7eed\u81f320\u5e74\u7684\u552e\u540e\u7ef4\u4fdd\u670d\u52a1\uff0c\u5305\u62ec\u5e74\u5ea6\u7cfb\u7edf\u68c0\u6d4b\u3001\u7ef4\u4fdd\u63d0\u9192\u3001\u6545\u969c\u6392\u67e5\u3001\u4f18\u5148\u54cd\u5e94\u3002\u670d\u52a1\u5185\u5bb9\u4e0d\u53d8\uff0c\u670d\u52a1\u6807\u51c6\u4e0d\u964d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u5c5e\u4e8e\u7cfb\u7edf\u539f\u56e0\u7684\u514d\u8d23\u60c5\u51b5<\/strong>\uff08\u4ecd\u63d0\u4f9b\u514d\u8d39\u8ddf\u8e2a\u5206\u6790\u62a5\u544a\u548c\u8282\u80fd\u5efa\u8bae\uff0c\u4f46\u4e0d\u627f\u62c5\u6539\u9020\u8d39\u7528\uff09\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u91c7\u6696\u5b63\u957f\u65f6\u95f4\u5f00\u7a97\u901a\u98ce<\/li>\n\n\n\n<li>\u5ba4\u5185\u6e29\u63a7\u5668\u6301\u7eed\u8bbe\u5b9a\u9ad8\u4e8e22\u2103\uff08\u8d85\u51fa\u8bbe\u8ba1\u57fa\u51c620\u2103\u00b12\u2103\uff09<\/li>\n\n\n\n<li>\u672a\u6309\u4ea4\u4ed8\u6559\u5b66\u8981\u6c42\u8fdb\u884c\u8865\u6c34\/\u6392\u6c14\/\u58c1\u6302\u7089\u53ca\u7cfb\u7edf\u6df1\u5ea6\u6e05\u6d17\u7b49\u57fa\u7840\u7ef4\u62a4<\/li>\n\n\n\n<li>\u623f\u5c4b\u4fdd\u6e29\u6761\u4ef6\u6539\u53d8\uff08\u5982\u62c6\u6539\u95e8\u7a97\u3001\u7834\u574f\u4fdd\u6e29\u5c42\uff09<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">DS\u6ce8\u610f\uff1a\u4ee5\u4e0a\u56db\u6761\u627f\u8bfa\u548c\u514d\u8d23\u6761\u6b3e\u5fc5\u987b\u5728\u6863\u6848\u7684&#8221;\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa&#8221;\u7ae0\u8282\u539f\u6587\u8f93\u51fa\uff0c\u4e0d\u5f97\u5220\u51cf\u3002<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\">\u6838\u5fc3\u539f\u5219\uff1a\u4e0d\u516c\u5f00\u3001\u4e0d\u6bd4\u8f83\u3001\u4e0d\u8bc4\u5224<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4e0d\u516c\u5f00<\/strong>\uff1a\u5ba2\u6237\u539f\u59cb\u6570\u636e\u4e0d\u5bf9\u5916\u516c\u5f00\uff0c\u4ec5\u5ba2\u6237\u672c\u4eba\u548c\u9f99\u8109\u5185\u90e8\u670d\u52a1\u56e2\u961f\u53ef\u89c1<\/li>\n\n\n\n<li><strong>\u4e0d\u6bd4\u8f83<\/strong>\uff1a\u4e0d\u5bf9\u5ba2\u6237\u8bf4&#8221;\u4f60\u5bb6\u6bd4\u522b\u4eba\u5bb6\u5dee&#8221;\uff0c\u53ea\u8bf4&#8221;\u540c\u6237\u578b\u5e73\u5747\u6c34\u5e73\u662fX\uff0c\u4f60\u5bb6\u662fY\uff0c\u5dee\u5f02\u53ef\u80fd\u6709\u4ee5\u4e0b\u51e0\u4e2a\u539f\u56e0\u2026\u2026&#8221;<\/li>\n\n\n\n<li><strong>\u4e0d\u8bc4\u5224<\/strong>\uff1a\u5ba2\u6237\u7684\u9009\u62e9\u6ca1\u6709\u5bf9\u9519\uff0c\u53ea\u63d0\u4f9b\u6570\u636e\u548c\u5206\u6790\uff0c\u51b3\u7b56\u6743\u6c38\u8fdc\u5728\u5ba2\u6237\u624b\u91cc<\/li>\n<\/ul>\n\n\n\n<h3 id=\"zl4044\" class=\"wp-block-heading\">4.4 \u6570\u636e\u91c7\u96c6\u89c4\u5219<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u8def\u5f84\u4e00\uff1a\u9505\u7089\u5730\u6696\u5ba2\u6237\uff08A\u7ec4\/B\u7ec4\u9505\u7089\u5730\u6696\uff09<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u5ba2\u6237\u62cd\u6444\u71c3\u6c14\u8868\u5f53\u524d\u8bfb\u6570\uff0c\u4f5c\u4e3a\u8d77\u70b9\u6570\u636e<\/li>\n\n\n\n<li>30\u5929\u540e\u518d\u62cd\u4e00\u5f20\uff0c\u5f97\u523030\u5929\u91c7\u6696\u7528\u6c14\u91cf<\/li>\n\n\n\n<li>\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\u91c7\u96c6\u71c3\u6c14\u8868\u8bfb\u6570\uff0c\u751f\u6210\u5e74\u5ea6\u62a5\u544a<\/li>\n\n\n\n<li><strong>\u4e0d\u80fd\u5355\u72ec\u52a0\u88c5\u71c3\u6c14\u8868<\/strong>\uff08\u71c3\u6c14\u516c\u53f8\u4e0d\u5141\u8bb8\uff09<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\">\u8def\u5f84\u4e8c\uff1a\u4e24\u8054\u4f9bB\u7ec4\u5ba2\u6237\uff08B-A \/ B-B\uff09<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u514d\u8d39\u5b89\u88c5\u667a\u80fd\u7535\u8868\uff0c\u4e0e\u4e3b\u673a\u540c\u6b65\u5b89\u88c5\uff0c\u4ea4\u4ed8\u524d\u8c03\u8bd5<\/li>\n\n\n\n<li>\u81ea\u52a8\u91c7\u96c6\uff1a\u6bcf\u65e5\/\u6bcf\u6708\/\u6bcf\u5e74\u4e3b\u673a\u8017\u7535\u91cf\u3001\u8fd0\u884c\u65f6\u957f\u3001\u542f\u505c\u6b21\u6570\u3001\u5cf0\u503c\u529f\u7387\u3001\u4f4e\u9891\u8fd0\u884c\u65f6\u957f<\/li>\n\n\n\n<li>\u80fd\u6e90\u7ba1\u7406\u5e73\u53f0\u63a5\u5165\u6c14\u8c61\u536b\u661f\u6570\u636e\uff0cAI\u81ea\u52a8\u5206\u6790\u8fd0\u884c\u72b6\u6001<\/li>\n\n\n\n<li>\u89e6\u53d1\u9884\u8b66\u65f6\u4e3b\u52a8\u8054\u7cfb\u5ba2\u6237<\/li>\n<\/ol>\n\n\n\n<h3 id=\"zl4045\" class=\"wp-block-heading\">4.5 \u6743\u76ca\u5206\u5c42<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u76ca<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u975e\u4f1a\u5458<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f1a\u5458<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8d28\u4fdd<\/td><td>5\u5e74\uff08\u9f99\u8109\u65bd\u5de5\u90e8\u5206\uff09<\/td><td>\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u670d\u52a1\u6298\u6263<\/td><td>\u6807\u51c6\u4ef7<\/td><td>5-8\u6298<\/td><\/tr><tr><td>\u514d\u8d39\u4e0a\u95e8<\/td><td>\u65e0<\/td><td>\u4e0d\u9650\u6b21\u6570<\/td><\/tr><tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u65e0<\/td><td>\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/td><\/tr><tr><td>\u5e74\u5ea6\u80fd\u8017\u62a5\u544a<\/td><td>\u65e0<\/td><td>\u6bcf\u5e74\u51fa\u5177<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u76ca<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u5730\u6696B\u7ec4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e24\u8054\u4f9bB\u7ec4<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8054\u52a8\u63a7\u5236\u5668<\/td><td>\u514d\u8d39<\/td><td>\u2014<\/td><\/tr><tr><td>\u667a\u80fd\u7535\u8868<\/td><td>\u2014<\/td><td>\u514d\u8d39<\/td><\/tr><tr><td>AI\u80fd\u6e90\u7ba1\u5bb6<\/td><td>\u2014<\/td><td>10\u5e74\u514d\u8d39<\/td><\/tr><tr><td>\u80fd\u8017\u8ddf\u8e2a\u65b9\u5f0f<\/td><td>\u71c3\u6c14\u8868\u8bfb\u6570<\/td><td>\u667a\u80fd\u7535\u8868\u81ea\u52a8\u91c7\u96c6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"zl4046\" class=\"wp-block-heading\">4.6 \u8131\u654f\u4e0e\u9690\u79c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7f16\u7801\u89c4\u5219<\/strong>\uff1a\u7ec4\u522b-\u533a\u57df-\u9879\u76ee-\u5e8f\u53f7\uff08\u5982 B-B-W-H-001 = B-B\u7ec4\u00b7\u6b66\u4faf\u533a\u00b7\u6e56\u4e0e\u767d\u00b7001\u53f7\uff09<\/li>\n\n\n\n<li><strong>\u516c\u5f00\u5c42<\/strong>\uff1a\u4ec5\u8131\u654f\u540e\u7684\u80fd\u8017\u8d8b\u52bf\u548c\u5bf9\u6bd4\uff0c\u4e0d\u5305\u542b\u59d3\u540d\u3001\u5177\u4f53\u5730\u5740\u3001\u54c1\u724c\u3001\u914d\u7f6e\u3001\u6210\u672c<\/li>\n\n\n\n<li><strong>\u4fdd\u5bc6\u5ba2\u6237<\/strong>\uff1a\u4e0d\u613f\u5206\u4eab\u4efb\u4f55\u6570\u636e\u7684\u5ba2\u6237\uff0c\u7b7e\u7f72\u4fdd\u5bc6\u534f\u8bae\uff0c\u4e0d\u7eb3\u5165\u5bf9\u6bd4\u516c\u793a<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl405\" class=\"wp-block-heading\">\u4e94\u3001\u6267\u884c\u6b65\u9aa4<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">DS\u5728\u677f\u5757\u4e09\u4e2d\u7684\u6267\u884c\u6d41<\/h3>\n\n\n\n<pre class=\"wp-block-preformatted\">\u5ba2\u6237\u62a5\u4ef7\u65b9\u6848\u751f\u6210\n  \u2502\n  \u251c\u2500 \u8bc6\u522b\u7cfb\u7edf\u7c7b\u578b\n  \u2502   \u251c\u2500 \u4e24\u8054\u4f9b \u2192 \u5f3a\u5236B\u7ec4\n  \u2502   \u2514\u2500 \u9505\u7089\u5730\u6696 \u2192 \u6309\u5ba2\u6237\u610f\u613f\u5224\u65adA\/B\u7ec4\n  \u2502\n  \u251c\u2500 \u8f93\u51fa\uff1a\u62a5\u4ef7\u672b\u5c3e\u9644\"\u4f1a\u5458\u6743\u76ca\u5361\u7247\"\uff08\u89c16.1\uff09\n  \u2502\n  \u2514\u2500 \u5ba2\u6237\u786e\u5b9a\u5206\u7ec4\u540e \u2192 \u8f93\u51fa\"\u5206\u7ec4\u786e\u8ba4\u6587\u672c\"\uff08\u89c16.3\uff09\n<\/pre>\n\n\n\n<h3 class=\"wp-block-heading\">DS\u5728\u677f\u5757\u56db\u4e2d\u7684\u6267\u884c\u6d41<\/h3>\n\n\n\n<pre class=\"wp-block-preformatted\">\u65b0\u5efa\u5ba2\u6237\u6863\u6848\n  \u2502\n  \u251c\u2500 \u786e\u8ba4\u5ba2\u6237\u5df2\u53c2\u4e0e10\u5e74\u8ba1\u5212 \u2192 \u8f93\u51fa\"10\u5e74\u80fd\u8017\u8ddf\u8e2a\u6a21\u677f\"\uff08\u89c16.2\uff09\n  \u2502\n  \u251c\u2500 \u786e\u8ba4\u5ba2\u6237\u672a\u53c2\u4e0e \u2192 \u65b9\u6848\u672b\u5c3e\u52a0\"10\u5e74\u8ba1\u5212\u9080\u8bf7\u8bed\"\uff08\u89c16.3\uff09\n  \u2502\n  \u2514\u2500 \u5df2\u53c2\u4e0e\u5ba2\u6237\u6bcf\u5e74\u6570\u636e\u66f4\u65b0 \u2192 \u66f4\u65b0\u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55\u8868\n<\/pre>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl406\" class=\"wp-block-heading\">\u516d\u3001\u8f93\u51fa\u7269\u683c\u5f0f<\/h2>\n\n\n\n<h3 id=\"zl4061\" class=\"wp-block-heading\">6.1 \u677f\u5757\u4e09\u62a5\u4ef7\u4e2d\u7684\u4f1a\u5458\u6743\u76ca\u5361\u7247<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u5728\u62a5\u4ef7\u65b9\u6848\u672b\u5c3e\u5fc5\u987b\u8f93\u51fa\uff1a<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">---\n\n### \u4f1a\u5458\u6743\u76ca\uff08199\u5143\/\u5e74\uff09\n\n\u7b7e\u7ea6\u5373\u4eab\u6696\u901a\u91d1\u989d1000\u5143\u62b5\u6263\u9996\u5e74\u4f1a\u8d39\uff0c\u76f8\u5f53\u4e8e\u9996\u5e740\u5143\u3002\u6696\u901a\u91d1\u989d\u8fd8\u53ef\u8986\u76d6\u524d5\u5e74\u4f1a\u8d39\uff08199\u00d75=995\u5143\uff09\uff0c\u524d5\u5e74\u4f1a\u5458\u8d390\u5143\u3002\n\n| \u6743\u76ca | \u5185\u5bb9 |\n|------|------|\n| \u8bbe\u5907\u5ef6\u4fdd | 5\u5e74\u5ef6\u4fdd\u81f310\u5e74 |\n| \u670d\u52a1\u6298\u6263 | \u6240\u6709\u670d\u52a1\u53ca\u8017\u67505-8\u6298 |\n| \u514d\u8d39\u4e0a\u95e8 | \u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8\uff0c\u4e0d\u9650\u6b21\u6570 |\n| \u4f18\u5148\u54cd\u5e94 | \u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355 |\n| 10\u5e74\u80fd\u8017\u8ddf\u8e2a | \u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a |\n\n\u4f1a\u5458\u8d39\u968f\u65f6\u53ef\u9000\uff0c\u63091\u5143\/\u5929\u6807\u51c6\u9000\u8fd8\u4f59\u989d\u3002\n\n---\n\n### 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\n\n\u7b7e\u7ea6\u5373\u52a0\u516510\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u3002\u6bcf\u5e74\u81ea\u52a8\u91c7\u96c6\u80fd\u8017\u6570\u636e\uff0c\u751f\u6210\u5206\u6790\u62a5\u544a\u3002\u56db\u4e2a\u65f6\u95f4\u8282\u70b9\u4ea4\u4ed8\uff1a\n- \u7b2c1\u5e74\uff1a\u300a\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848\u300b\n- \u7b2c3\u5e74\uff1a\u300a3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a\u300b\n- \u7b2c5\u5e74\uff1a\u300a\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\u300b\n- \u7b2c10\u5e74\uff1a\u300a10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u300b\n<\/pre>\n\n\n\n<h3 id=\"zl4062\" class=\"wp-block-heading\">6.2 \u677f\u5757\u56db\u6863\u6848\u4e2d\u768410\u5e74\u80fd\u8017\u8ddf\u8e2a\u6a21\u677f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u5728\u5ba2\u6237\u6863\u6848\u4e2d\u5fc5\u987b\u8f93\u51fa\u4ee5\u4e0b\u8868\u683c\u7ed3\u6784\uff08\u5b57\u6bb5\u7981\u7528emoji\u7b26\u53f7\uff0c\u4ec5\u4fdd\u7559\u6587\u5b57\uff09\uff1a<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u6570\u636e\u57fa\u51c6\uff08\u8c03\u8bd5\u5f53\u65e5\u8bb0\u5f55\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u57fa\u51c6\u6570\u636e<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8c03\u8bd5\u65e5\u671f<\/td><td>\u5e74 \u6708 \u65e5<\/td><\/tr><tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>___ \u2103<\/td><\/tr><tr><td>\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6<\/td><td>___ \u2103<\/td><\/tr><tr><td>\u5ba4\u5916\u6e29\u5ea6<\/td><td>___ \u2103<\/td><\/tr><tr><td>\u671f\u95f4\u71c3\u6c14\u91cf<\/td><td>___ m\u00b3<\/td><\/tr><tr><td>\u9505\u7089\u578b\u53f7<\/td><td>___<\/td><\/tr><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>___ \u33a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u5b63(\u6708)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u603b\u7528\u6c14\u91cf(m\u00b3)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u603b\u8d39\u7528(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6708\u5747\u8d39\u7528(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d\u8d39\u7528(\u5143\/\u33a1\u00b7\u6708)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e1a\u4e3b\u53cd\u9988<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u7b2c1\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c2\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c3\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c4\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c5\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c6\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c7\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c8\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c9\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c10\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u80fd\u8017\u5bf9\u6807\u57fa\u51c6<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u53c2\u8003\u6237\u578b<\/td><td>{\u91c7\u6696\u9762\u79ef}\u33a1 \u00b7 \u51b7\u51dd\u7089\u5730\u6696 \u00b7 \u5ba4\u6e2920\u2103 \u00b7 \u6210\u90fd\u5730\u533a<\/td><\/tr><tr><td>\u53c2\u8003\u5b63\u8d39\u7528<\/td><td>\u7ea6 {\u8ba1\u7b97\u503c} \u5143\/\u5b63<\/td><\/tr><tr><td>\u8ba1\u7b97\u516c\u5f0f<\/td><td>\u91c7\u6696\u9762\u79ef \u00d7 50W\/m\u00b2 \u00d7 24h \u00d7 120\u5929 \u00f7 10 \u00f7 95% \u00d7 2.5\u5143\/\u65b9<\/td><\/tr><tr><td>\u70ed\u6548\u7387<\/td><td>95%\uff08\u6309\u4f4e\u4f4d\u70ed\u503c\uff09<\/td><\/tr><tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>\u226450\u2103\uff08\u51b7\u51dd\u5de5\u51b5\uff09<\/td><\/tr><tr><td>\u5ba4\u6e29\u8bbe\u5b9a<\/td><td>20\u2103 \u00b1 1\u2103<\/td><\/tr><tr><td>\u5efa\u7b51\u6761\u4ef6<\/td><td>\u8282\u80fd\u5efa\u7b51\uff08GB 50189-2015\uff09<\/td><\/tr><tr><td>\u6c14\u4ef7<\/td><td>2.5\u5143\/\u65b9\uff08\u6210\u90fd\u5c45\u6c11\u7528\u6c14\u7b2c\u4e8c\u9636\u68af\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">DS\u6ce8\u610f\uff1a\u8ba1\u7b97\u516c\u5f0f\u4e2d\u91c7\u6696\u9762\u79ef\u5fc5\u987b\u586b\u5165\u5b9e\u9645\u9762\u79ef\uff1b\u53c2\u8003\u5b63\u8d39\u7528\u4e3a\u81ea\u52a8\u8ba1\u7b97\u503c\u3002<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\">\u504f\u5dee\u8bf4\u660e<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u56e0\u7d20\u4f1a\u5bfc\u81f4\u5b9e\u9645\u8d39\u7528\u9ad8\u4e8e\u53c2\u8003\u503c\uff08\u504f\u5dee+20%~+50%\uff09\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5ba4\u6e29\u8bbe\u5b9a\u6bcf\u63d0\u9ad81\u2103 \u2192 \u80fd\u8017\u589e\u52a0\u7ea65-10%<\/li>\n\n\n\n<li>\u4f9b\u6c34\u6e29\u5ea6\u9ad8\u4e8e55\u2103 \u2192 \u51b7\u51dd\u7089\u9000\u51fa\u51b7\u51dd\u5de5\u51b5\uff0c\u6548\u7387\u964d\u81f390%\u4ee5\u4e0b<\/li>\n\n\n\n<li>\u975e\u8282\u80fd\u5efa\u7b51\uff08\u8001\u623f\u3001\u65e0\u4fdd\u6e29\uff09 \u2192 \u70ed\u8d1f\u8377\u53ef\u80fd\u8fbe80-120W\/\u33a1<\/li>\n\n\n\n<li>\u9891\u7e41\u5f00\u7a97\u6362\u6c14 \u2192 \u70ed\u635f\u5931\u589e\u52a020-40%<\/li>\n\n\n\n<li>\u5165\u4f4f\u7387\u4f4e\uff08\u95f4\u6b47\u4f9b\u6696\uff09 \u2192 \u5730\u6696\u5347\u6e29\u6162\uff0c\u9891\u7e41\u542f\u505c\u53cd\u800c\u8d39\u6c14<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u670d\u52a1\u8bb0\u5f55<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65e5\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u4eba\u5458<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u786e\u8ba4<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4f18\u5316\u5efa\u8bae\u8ddf\u8e2a\u8868<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u65e5\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6267\u884c\u60c5\u51b5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6548\u679c\u9a8c\u8bc1<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8ddf\u8e2a\u72b6\u6001<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"zl4063\" class=\"wp-block-heading\">6.3 \u5206\u7ec4\u786e\u8ba4\u8f93\u51fa\u683c\u5f0f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u5728\u5ba2\u6237\u786e\u5b9a\u5206\u7ec4\u540e\u8f93\u51fa\uff1a<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">### 10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212 \u2014 \u5206\u7ec4\u786e\u8ba4\n\n**\u5ba2\u6237\u59d3\u540d**\uff1a___\n**\u9879\u76ee\u5730\u5740**\uff1a___\n**\u9009\u62e9\u7ec4\u522b**\uff1a___\n**\u5b50\u7ec4**\uff1a___\n**\u7cfb\u7edf\u7c7b\u578b**\uff1a___\uff08\u9505\u7089\u5730\u6696 \/ \u4e24\u8054\u4f9b\uff09\n\n**\u7b7e\u7ea6\u5373\u786e\u8ba4**\uff1a\n- \u52a0\u5165\u9f99\u8109\u6696\u901a10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\n- \u6388\u6743\u9f99\u8109\u6696\u901a\u6bcf\u5e74\u91c7\u96c6\u80fd\u8017\u6570\u636e\n- \u6570\u636e\u8131\u654f\u540e\u7eb3\u5165\u540c\u6237\u578b\u5bf9\u6807\u6837\u672c\u5e93\uff08\u5ba2\u6237\u53ef\u7b7e\u7f72\u4fdd\u5bc6\u534f\u8bae\u4e0d\u53c2\u4e0e\u5bf9\u6807\uff09\n- \u4eab\u53d7\u5bf9\u5e94\u7ec4\u522b\u7684\u5168\u90e8\u6743\u76ca\n\n**\u4e00\u5f0f\u4e24\u4efd\uff0c\u5ba2\u6237\u4e0e\u9f99\u8109\u5404\u7559\u5b58\u4e00\u4efd\u3002**\n<\/pre>\n\n\n\n<h3 class=\"wp-block-heading\">6.4\u6863\u6848\u7f16\u53f7\uff1a\u5ba2\u6237\u6863\u6848\u7f16\u7ec4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c<\/strong>\uff1aV1.0<br><strong>\u66f4\u65b0\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670823\u65e5<br><strong>\u524d\u7f00<\/strong>\uff1aLM\uff08\u9f99\u8109\uff09<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e00\u3001\u7f16\u53f7\u683c\u5f0f<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><code>LM-\u5e74\u4efd-\u5c0f\u533a\u62fc\u97f3\u9996\u5b57\u6bcd-\u5206\u7ec4-\u5e8f\u53f7<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u793a\u4f8b\uff1a<code>LM-2026-tfgg-B-B-001<\/code><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e8c\u3001\u5206\u7ec4\u4ee3\u7801<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u7801<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u542b\u4e49<\/th><\/tr><\/thead><tbody><tr><td>A-A<\/td><td>\u5ba2\u6237\u81ea\u9009\u65b9\u6848\uff0c\u6211\u4eec\u53ea\u65bd\u5de5<\/td><\/tr><tr><td>A-B<\/td><td>\u5ba2\u6237\u90e8\u5206\u91c7\u7eb3\u6211\u4eec\u5efa\u8bae<\/td><\/tr><tr><td>B-A<\/td><td>\u8ba4\u53ef\u6211\u4eec\u8bbe\u8ba1\u4f46\u6709\u6240\u4fdd\u7559<\/td><\/tr><tr><td>B-B<\/td><td>\u5b8c\u5168\u6309\u6211\u4eec\u65b9\u6848\u6267\u884c<\/td><\/tr><tr><td>P<\/td><td>\u4ec5\u91c7\u8d2d\u8bbe\u5907<\/td><\/tr><tr><td>S<\/td><td>\u4ec5\u552e\u540e\u670d\u52a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e09\u3001\u5c0f\u533a\u4ee3\u7801\uff08\u62fc\u97f3\u9996\u5b57\u6bcd\uff0c\u5c0f\u5199\uff09<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u533a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u7801<\/th><\/tr><\/thead><tbody><tr><td>\u5929\u5e9c\u516c\u9986<\/td><td>tfgg<\/td><\/tr><tr><td>\u9e93\u6e56\u751f\u6001\u57ce<\/td><td>lhstc<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u589e\u5c0f\u533a\uff1a\u53d6\u62fc\u97f3\u9996\u5b57\u6bcd\uff0c\u5c0f\u5199\uff0c\u4e0d\u8bbe\u957f\u5ea6\u9650\u5236\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u56db\u3001\u89c4\u5219<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7b7e\u7ea6\u540e\u7531\u65b9\u6848DS\u751f\u6210\u7f16\u53f7<\/li>\n\n\n\n<li>\u5386\u53f2\u6863\u6848\uff08LY\u524d\u7f00\uff09\u4e0d\u5f3a\u5236\u4fee\u6539<\/li>\n\n\n\n<li>\u65b0\u6863\u6848\u7edf\u4e00\u7528LM\u524d\u7f00<\/li>\n\n\n\n<li>\u65b0\u589e\u5ba2\u6237ID\uff0c\u5ba2\u6237ID\u793a\u4f8b |KH2026-05034| \u7cfb\u7edf\u4e3b\u952e\uff0c\u5c0f\u7a0b\u5e8f\u67e5\u8be2\uff0c\u7b80\u9053\u4e91\u5173\u8054 | \u7b80\u9053\u4e91\u81ea\u52a8\u751f\u6210 |<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl407\" class=\"wp-block-heading\">\u4e03\u3001\u9a8c\u8bc1\u6e05\u5355<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u8f93\u51fa\u540e\u81ea\u67e5\u4ee5\u4e0b11\u9879\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;1. \u62a5\u4ef7\u65b9\u6848\u672b\u5c3e\u662f\u5426\u9644\u4e86\u4f1a\u5458\u6743\u76ca\u5361\u7247\uff1f<\/li>\n\n\n\n<li>&nbsp;2. \u4f1a\u5458\u6743\u76ca\u5361\u7247\u4e2d\u662f\u5426\u5305\u542b&#8221;\u9996\u5e740\u5143&#8221;\u548c&#8221;\u524d5\u5e74\u514d\u4f1a\u8d39&#8221;\uff1f<\/li>\n\n\n\n<li>&nbsp;3. \u4e24\u8054\u4f9b\u5ba2\u6237\u662f\u5426\u5f3a\u5236\u6807\u6ce8B\u7ec4\uff1f<\/li>\n\n\n\n<li>&nbsp;4. \u6863\u6848\u4e2d\u662f\u5426\u542b\u6570\u636e\u57fa\u51c6\u8868\uff08\u4f9b\u6c34\u6e29\u5ea6\u3001\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6\u3001\u5ba4\u5916\u6e29\u5ea6\u3001\u671f\u95f4\u71c3\u6c14\u91cf\uff09\uff1f<\/li>\n\n\n\n<li>&nbsp;5. \u6570\u636e\u57fa\u51c6\u8868\u4e2d\u662f\u5426<strong>\u4e0d\u5305\u542b\u56de\u6c34\u6e29\u5ea6<\/strong>\uff1f<\/li>\n\n\n\n<li>&nbsp;6. \u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55\u8868\u662f\u542610\u884c\u5b8c\u6574\uff1f<\/li>\n\n\n\n<li>&nbsp;7. \u80fd\u8017\u5bf9\u6807\u57fa\u51c6\u8ba1\u7b97\u516c\u5f0f\u4e2d\u7684\u91c7\u6696\u9762\u79ef\u662f\u5426\u4e3a\u5b9e\u9645\u503c\uff08\u975e\u6a21\u677f\u5360\u4f4d\u7b26\uff09\uff1f<\/li>\n\n\n\n<li>&nbsp;8. \u5206\u7ec4\u786e\u8ba4\u4e2d\u662f\u5426\u5305\u542b\u6570\u636e\u6388\u6743\u58f0\u660e\uff1f<\/li>\n\n\n\n<li>&nbsp;9. \u9505\u7089\u5730\u6696B\u7ec4\u65b9\u6848\u662f\u5426\u5305\u542b&#8221;\u514d\u8d39\u8054\u52a8\u63a7\u5236\u5668&#8221;\uff1f<\/li>\n\n\n\n<li>&nbsp;10. \u4e24\u8054\u4f9bB\u7ec4\u65b9\u6848\u662f\u5426\u5305\u542b&#8221;\u514d\u8d39\u667a\u80fd\u7535\u8868 + AI\u80fd\u6e90\u7ba1\u5bb6&#8221;\uff1f<\/li>\n\n\n\n<li>&nbsp;11. \u6863\u6848\u4e2d\u662f\u5426\u5305\u542b\u5b8c\u6574\u7684&#8221;\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa&#8221;\uff08\u56db\u6761\u627f\u8bfa+\u514d\u8d23\u6761\u6b3e\uff09\uff1f<\/li>\n\n\n\n<li>&nbsp;12. \u6863\u6848\u4e2d\u662f\u5426\u5305\u542b&#8221;\u6838\u5fc3\u539f\u5219\uff1a\u4e0d\u516c\u5f00\u3001\u4e0d\u6bd4\u8f83\u3001\u4e0d\u8bc4\u5224&#8221;\uff1f<\/li>\n\n\n\n<li>&nbsp;13. \u8f93\u51fa\u7269\u4e2d\u662f\u5426\u5b8c\u5168\u4e0d\u542bemoji\u7b26\u53f7\uff1f<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl408\" class=\"wp-block-heading\">\u516b\u3001\u7981\u6b62\u884c\u4e3a<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u7981\u6b62\u4e3aA\u7ec4\u5ba2\u6237\u7701\u756510\u5e74\u8ba1\u5212<\/strong>\uff1aA\u7ec4\u540c\u6837\u4eab\u53d7\u8ddf\u8e2a\uff0c\u53ea\u662f\u80fd\u6e90\u7ba1\u7406\u65b9\u5f0f\u4e0d\u540c\uff08\u65e0\u667a\u80fd\u7535\u8868\uff09<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u6697\u793aA\u7ec4&#8221;\u4e0d\u5982B\u7ec4&#8221;<\/strong>\uff1a\u5206\u7ec4\u662f\u5ba2\u6237\u81ea\u4e3b\u9009\u62e9\uff0cDS\u53ea\u5448\u73b0\u89c4\u5219\u4e0d\u8bc4\u5224<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u865a\u6784\u6298\u6263<\/strong>\uff1a\u4f1a\u5458\u6298\u62635-8\u6298\uff0c\u4e0d\u5f97\u5199&#8221;\u6700\u4f4e3\u6298&#8221;\u7b49\u865a\u6784\u4f18\u60e0<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u5728\u65b9\u6848\u4e66\u6b63\u6587\u957f\u7bc7\u5c55\u5f0010\u5e74\u8ba1\u5212<\/strong>\uff1a\u677f\u5757\u4e09\u53ea\u653e\u4f1a\u5458\u6743\u76ca\u5361\u7247+\u4e00\u53e5\u8bdd\uff0c\u8be6\u7ec6\u5185\u5bb9\u653e\u5728\u677f\u5757\u56db\u6863\u6848\u4e2d<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u4e3a\u9505\u7089\u5730\u6696\u5ba2\u6237\u5199&#8221;\u514d\u8d39\u667a\u80fd\u7535\u8868&#8221;<\/strong>\uff1a\u667a\u80fd\u7535\u8868\u4ec5\u4e24\u8054\u4f9bB\u7ec4\u4eab\u6709<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u5728\u6570\u636e\u57fa\u51c6\u8868\u4e2d\u586b\u5165\u56de\u6c34\u6e29\u5ea6<\/strong><\/li>\n\n\n\n<li><strong>\u7981\u6b62\u4f7f\u7528emoji\u7b26\u53f7<\/strong>\uff1a\u6240\u6709\u8868\u683c\u548c\u6b63\u6587\u4e00\u5f8b\u7eaf\u6587\u5b57<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u5728\u5ba2\u6237\u672a\u95ee\u5206\u7ec4\u65f6\u4e3b\u52a8\u5728\u677f\u5757\u4e00\u3001\u677f\u5757\u4e8c\u4e2d\u63d2\u516510\u5e74\u8ba1\u5212\u63a8\u8350<\/strong>\uff1a\u4ec5\u5728\u677f\u5757\u4e09\u62a5\u4ef7\u73af\u8282\u51fa\u73b0<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e5d\u3001\u5e38\u89c1\u9519\u8bef<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9519\u8bef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6b63\u786e\u505a\u6cd5<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u7ed9\u4e24\u8054\u4f9b\u5ba2\u6237\u9009\u4e86A\u7ec4<\/td><td>\u4e24\u8054\u4f9b\u5f3a\u5236B\u7ec4\uff0c\u4e0d\u53ef\u9009A\u7ec4<\/td><\/tr><tr><td>\u62a5\u4ef7\u65b9\u6848\u4e2d\u957f\u7bc7\u5927\u8bba10\u5e74\u8ba1\u5212<\/td><td>\u677f\u5757\u4e09\u53ea\u653e\u4f1a\u5458\u6743\u76ca\u5361\u7247\uff1b\u8be6\u7ec6\u5185\u5bb9\u653e\u677f\u5757\u56db\u6863\u6848<\/td><\/tr><tr><td>\u7ed9\u9505\u7089\u5730\u6696\u5ba2\u6237\u5199\u4e86\u514d\u8d39\u667a\u80fd\u7535\u8868<\/td><td>\u4ec5\u4e24\u8054\u4f9bB\u7ec4\u914d\u5907\u667a\u80fd\u7535\u8868\uff0c\u9505\u7089\u5730\u6696\u8d70\u71c3\u6c14\u8868\u8bfb\u6570\u8def\u5f84<\/td><\/tr><tr><td>\u6570\u636e\u57fa\u51c6\u8868\u5199\u4e86\u56de\u6c34\u6e29\u5ea6<\/td><td>\u56de\u6c34\u6e29\u5ea6\u4e0d\u53ef\u6d4b\uff0c\u8868\u4e2d\u53ea\u4fdd\u7559\u4f9b\u6c34\u6e29\u5ea6<\/td><\/tr><tr><td>\u5199&#8221;\u71c3\u6c14\u8868\u521d\u59cb\u8bfb\u6570&#8221;<\/td><td>\u5e94\u5199&#8221;\u671f\u95f4\u71c3\u6c14\u91cf&#8221;<\/td><\/tr><tr><td>\u4f1a\u5458\u6743\u76ca\u5361\u7247\u6f0f\u5199\u9000\u6b3e\u89c4\u5219<\/td><td>\u5fc5\u987b\u5305\u542b&#8221;\u968f\u65f6\u53ef\u9000\uff0c\u63091\u5143\/\u5929\u9000\u8fd8\u4f59\u989d&#8221;<\/td><\/tr><tr><td>\u6863\u6848\u80fd\u8017\u5bf9\u6807\u57fa\u51c6\u7528\u4e86\u6a21\u677f\u5360\u4f4d\u7b26<\/td><td>\u91c7\u6696\u9762\u79ef\u5fc5\u987b\u4ee3\u5165\u5b9e\u9645\u6570\u503c<\/td><\/tr><tr><td>\u6863\u6848\u4e2d\u6f0f\u4e86\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa\u56db\u6761\u6b3e<\/td><td>\u5fc5\u987b\u539f\u6587\u8f93\u51fa\u56db\u6761\u627f\u8bfa+\u514d\u8d23\u6761\u6b3e\uff0c\u4e0d\u53ef\u5220\u51cf<\/td><\/tr><tr><td>\u6863\u6848\u4e2d\u6f0f\u4e86\u6838\u5fc3\u539f\u5219\u7ae0\u8282<\/td><td>\u6863\u6848\u4e2d\u5fc5\u987b\u6709&#8221;\u4e0d\u516c\u5f00\u3001\u4e0d\u6bd4\u8f83\u3001\u4e0d\u8bc4\u5224&#8221;\u72ec\u7acb\u5c0f\u8282<\/td><\/tr><tr><td>\u8f93\u51fa\u542bemoji\u7b26\u53f7<\/td><td>\u5168\u6587\u6863\u7981\u7528emo<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl410\" class=\"wp-block-heading\">\u5341\u3001\u5173\u8054\u77e5\u8bc6\u5e93<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6587\u6863<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7528\u9014<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f4d\u7f6e<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u6307\u4ee40\u00b7\u5baa\u6cd5<\/td><td>\u6d41\u7a0b\u7f16\u6392\u3001\u677f\u5757\u8fb9\u754c\u5b9a\u4e49<\/td><td>\u6307\u4ee40<\/td><\/tr><tr><td>\u6307\u4ee41\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u77e5\u8bc6\u7d22\u5f15<\/td><td>\u6280\u672f\u7ea2\u7ebf\u3001\u8bbe\u8ba1\u53c2\u6570<\/td><td>\u6307\u4ee41<\/td><\/tr><tr><td>\u6307\u4ee42\u00b7\u4ef7\u683c\u8868<\/td><td>\u62a5\u4ef7\u53c2\u8003<\/td><td>\u6307\u4ee42<\/td><\/tr><tr><td>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u00b7\u5ba2\u6237\u7248<\/td><td>\u5ba2\u6237\u9605\u8bfb\u7684\u6d3b\u52a8\u8be6\u60c5<\/td><td>\u9f99\u8109\u5b98\u7f51 page_id=518<\/td><\/tr><tr><td>\u7ba1\u8001\u5e08\u6863\u6848\u00b7\u771f\u5b9e\u6837\u672c<\/td><td>\u6863\u6848\u8f93\u51fa\u683c\u5f0f\u53c2\u8003<\/td><td>\u9f99\u8109\u5b98\u7f51 page_id=982<\/td><\/tr><tr><td>\u5468\u8001\u5e08\u6863\u6848\u00b7\u5730\u6696\u6d4b\u8bc4\u5b98\u6837\u672c<\/td><td>\u9505\u7089\u5730\u6696\u6863\u6848\u53c2\u8003<\/td><td>\u5185\u90e8\u6587\u6863<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c<\/strong>\uff1aV2.0 |&nbsp;<strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670822\u65e5 |&nbsp;<strong>\u91cd\u6784\u4f9d\u636e<\/strong>\uff1apage_id=518\uff0810\u5e74\u8ba1\u5212\u9080\u8bf7\uff09+ page_id=982\uff08\u7ba1\u8001\u5e08\u6863\u6848\uff09+ \u6307\u4ee44 V1.0\u539f\u6587<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>DS\u6267\u884c\u89c4\u5219 V2.0 \u76ee\u5f55 \u4e00\u3001\u6307\u4ee4\u76ee [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-886","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"DS\u6267\u884c\u89c4\u5219 V2.0 \u76ee\u5f55 \u4e00\u3001\u6307\u4ee4\u76ee [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=886\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-29T07:08:11+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=886\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=886\",\"name\":\"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-17T07:40:23+00:00\",\"dateModified\":\"2026-05-29T07:08:11+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=886#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=886\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=886#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4 - \u9f99\u8109\u6696\u901a","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"zh_CN","og_type":"article","og_title":"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4 - \u9f99\u8109\u6696\u901a","og_description":"DS\u6267\u884c\u89c4\u5219 V2.0 \u76ee\u5f55 \u4e00\u3001\u6307\u4ee4\u76ee [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=886","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-29T07:08:11+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=886","url":"https:\/\/longmai-nt.com\/?page_id=886","name":"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-17T07:40:23+00:00","dateModified":"2026-05-29T07:08:11+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=886#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=886"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=886#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6307\u4ee44\uff1a\u9f99\u8109\u6696\u901a\u00b7\u4f1a\u5458\u5236\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u6307\u4ee4"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/886","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=886"}],"version-history":[{"count":7,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/886\/revisions"}],"predecessor-version":[{"id":1836,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/886\/revisions\/1836"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=886"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}