{"id":9104,"date":"2026-07-30T12:06:45","date_gmt":"2026-07-30T04:06:45","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=9104"},"modified":"2026-08-07T23:30:26","modified_gmt":"2026-08-07T15:30:26","slug":"%e4%b8%ad%e9%93%81%e9%bb%91%e9%be%99%e6%bb%a9%e6%98%9f%e6%9c%88%e4%ba%91%e6%b9%96-%c2%b7-%e6%9c%b1%e5%85%88%e7%94%9f%e5%85%a8%e5%b1%8b%e6%9a%96%e9%80%9a%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e4%b9%a6-2","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=9104","title":{"rendered":"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66"},"content":{"rendered":"\n\n<style>\n\/* ===== V1.3 \u9ed1\u5e95\u91d1\u4e3b\u9898\uff08\u4ec5<html>\u6807\u7b7eclass\u5207\u6362\u6362\u80a4\uff09 ===== *\/\n:root{\n  --gold:#c9a14a;\n  --gold-l:#e8c97e;\n  --gold-d:#8a6a26;\n  --ink:#0c0c10;\n  --ink-2:#1a1a22;\n  --ink-3:#26262f;\n  --line:#3a3a47;\n  --txt:#e6e6ea;\n  --txt-s:#9a9aa6;\n  --red:#d44a4a;\n  --green:#3aaf76;\n  --blue:#4a8ad4;\n  --warn:#e8a035;\n}\n*{box-sizing:border-box;margin:0;padding:0}\nhtml{scroll-behavior:smooth}\nbody{\n  font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",\"PingFang SC\",\"Hiragino Sans GB\",\"Microsoft YaHei\",sans-serif;\n  background:var(--ink);color:var(--txt);line-height:1.7;font-size:15px;\n  -webkit-font-smoothing:antialiased;\n}\n\n\/* ===== \u82f1\u96c4\u533a\u00b7\u9ed1\u5e95\u91d1\u4e3b\u9898 ===== *\/\n.hero{\n  position:relative;min-height:400px;\n  background:linear-gradient(135deg,#08080c 0%,#16161e 60%,#1f1f2a 100%);\n  color:#fff;display:flex;flex-direction:column;justify-content:center;align-items:center;text-align:center;\n  padding:50px 20px 40px;overflow:hidden;\n}\n.hero::before{\n  content:\"\";position:absolute;inset:0;\n  background:\n    radial-gradient(circle at 20% 30%,rgba(201,161,74,.18) 0%,transparent 40%),\n    radial-gradient(circle at 80% 70%,rgba(201,161,74,.10) 0%,transparent 50%);\n  z-index:0;\n}\n.hero>*{position:relative;z-index:1}\n.hero .kicker{\n  font-size:.78rem;letter-spacing:4px;color:var(--gold);\n  text-transform:uppercase;margin-bottom:8px;font-weight:500;\n}\n.hero h1{\n  font-size:1.65rem;font-weight:800;margin-bottom:10px;\n  background:linear-gradient(90deg,#fff 0%,var(--gold-l) 50%,#fff 100%);\n  -webkit-background-clip:text;background-clip:text;-webkit-text-fill-color:transparent;\n  color:transparent;letter-spacing:1px;\n}\n.hero .sub{font-size:.92rem;color:#d0d0d8;max-width:760px;margin:0 auto}\n.hero .price-tag{\n  display:inline-block;margin:18px auto 0;padding:8px 22px;\n  background:rgba(201,161,74,.18);border:1px solid var(--gold);\n  border-radius:999px;font-size:1.05rem;color:var(--gold-l);font-weight:700;letter-spacing:1px;\n}\n.hero .ids{\n  display:flex;flex-wrap:wrap;gap:10px;justify-content:center;margin-top:22px;max-width:820px;\n}\n.hero .id-chip{\n  background:rgba(201,161,74,.08);border:1px solid rgba(201,161,74,.55);\n  border-radius:999px;padding:6px 16px;font-size:.76rem;\n  color:var(--gold-l);letter-spacing:.5px;backdrop-filter:blur(4px);\n}\n\n\/* ===== \u76ee\u5f55\u5bfc\u822a sticky ===== *\/\n.toc-nav{\n  position:sticky;top:0;z-index:50;\n  background:rgba(12,12,16,.96);backdrop-filter:blur(10px);\n  border-bottom:1px solid var(--gold-d);\n  padding:10px 0;box-shadow:0 2px 12px rgba(0,0,0,.4);\n}\n.toc-inner{max-width:880px;margin:0 auto;padding:0 18px}\n.toc-title{\n  font-size:.74rem;color:var(--gold);letter-spacing:3px;\n  display:flex;align-items:center;gap:8px;margin-bottom:8px;font-weight:600;\n}\n.toc-grid{\n  display:grid;grid-template-columns:repeat(8,1fr);gap:6px;\n}\n.toc-grid a{\n  display:block;text-align:center;padding:7px 4px;\n  background:var(--ink-2);border:1px solid var(--line);\n  border-radius:6px;font-size:.74rem;color:var(--txt-s);\n  text-decoration:none;transition:all .2s;\n}\n.toc-grid a:hover{\n  background:var(--ink-3);border-color:var(--gold);color:var(--gold-l);\n}\n.toc-grid a .n{display:block;font-size:.62rem;color:var(--gold);margin-bottom:1px}\n\n\/* ===== \u5185\u5bb9\u5bb9\u5668 ===== *\/\n.wrap{max-width:880px;margin:0 auto;padding:30px 20px 40px}\n\n\/* ===== \u7ae0\u8282\u5361\u7247\u00b7\u9ed1\u5e95\u91d1\u4e3b\u9898 ===== *\/\n.sec{\n  margin:24px 0;background:var(--ink-2);\n  border:1px solid var(--line);border-radius:14px;padding:24px 26px;\n  scroll-margin-top:80px;\n}\n.sec h2{\n  font-size:1.18rem;color:var(--gold-l);\n  margin:0 0 16px;padding-bottom:8px;\n  border-bottom:1px solid var(--gold-d);\n  display:flex;align-items:center;gap:8px;\n}\n.sec h3{font-size:.96rem;color:var(--gold);margin:18px 0 10px;font-weight:600}\n.sec h4{font-size:.86rem;color:var(--txt);margin:12px 0 6px;font-weight:600}\n.sec p,.sec li{font-size:.9rem;color:var(--txt);margin:6px 0}\n\n\/* ===== \u8868\u683c\u00b7\u9ed1\u5e95 ===== *\/\ntable{\n  width:100%;border-collapse:collapse;margin:12px 0;\n  font-size:.84rem;background:var(--ink-3);\n}\nth,td{\n  border:1px solid var(--line);padding:8px 10px;\n  text-align:center;color:var(--txt);\n}\nth{\n  background:linear-gradient(180deg,#2a2a36 0%,#1f1f28 100%);\n  color:var(--gold-l);font-weight:600;font-size:.82rem;\n  letter-spacing:.5px;\n}\ntr:nth-child(even) td{background:rgba(255,255,255,.02)}\ntfoot td{background:var(--ink-2);font-weight:700;color:var(--gold-l)}\n\n\/* ===== \u5f3a\u8c03\u76d2\u5b50 ===== *\/\n.box-gold{\n  background:linear-gradient(180deg,rgba(201,161,74,.08) 0%,rgba(201,161,74,.04) 100%);\n  border-left:4px solid var(--gold);border-radius:0 10px 10px 0;\n  padding:14px 18px;margin:14px 0;font-size:.88rem;\n}\n.box-green{\n  background:rgba(58,175,118,.10);border-left:4px solid var(--green);\n  border-radius:0 10px 10px 0;padding:14px 18px;margin:14px 0;font-size:.88rem;\n}\n.box-red{\n  background:rgba(212,74,74,.08);border-left:4px solid var(--red);\n  border-radius:0 10px 10px 0;padding:14px 18px;margin:14px 0;font-size:.88rem;\n}\n.box-warn{\n  background:rgba(232,160,53,.08);border-left:4px solid var(--warn);\n  border-radius:0 10px 10px 0;padding:14px 18px;margin:14px 0;font-size:.88rem;\n}\n.box-blue{\n  background:rgba(74,138,212,.08);border-left:4px solid var(--blue);\n  border-radius:0 10px 10px 0;padding:14px 18px;margin:14px 0;font-size:.88rem;\n}\n\n\/* ===== ID\u4e3b\u952e\u5757 ===== *\/\n.id-block{\n  background:linear-gradient(180deg,#0a0a10 0%,#16161e 100%);\n  border:1px solid var(--gold-d);border-radius:12px;\n  padding:16px 18px;margin:10px 0;\n}\n.id-block .hint{font-size:.76rem;color:var(--txt-s);margin-bottom:10px;letter-spacing:.5px}\n.id-block .row{\n  display:grid;grid-template-columns:repeat(4,1fr);\n  gap:10px;margin-top:8px;\n}\n.id-block .cell{\n  background:var(--ink-3);border:1px solid var(--line);\n  border-radius:8px;padding:11px 8px;text-align:center;\n}\n.id-block .cell .k{\n  font-size:.66rem;color:var(--gold);letter-spacing:1.5px;\n  text-transform:uppercase;margin-bottom:3px;\n}\n.id-block .cell .v{\n  font-size:.84rem;color:#fff;font-weight:600;\n  word-break:break-all;line-height:1.4;\n}\n.id-block .cell .v.muted{color:var(--txt-s);font-weight:400;font-size:.78rem}\n\n\/* ===== \u4e94\u6001\u8272\u73af ===== *\/\n.state-chip{\n  display:inline-flex;align-items:center;gap:7px;\n  padding:6px 14px;border-radius:999px;font-size:.8rem;font-weight:600;\n  margin:3px 4px 3px 0;\n}\n.state-chip .dot{\n  width:11px;height:11px;border-radius:50%;\n  box-shadow:0 0 8px currentColor;\n}\n.state-yellow{background:rgba(232,160,53,.15);color:var(--warn);border:1px solid var(--warn)}\n.state-yellow .dot{background:var(--warn)}\n.state-green{background:rgba(58,175,118,.15);color:var(--green);border:1px solid var(--green)}\n.state-green .dot{background:var(--green)}\n.state-red{background:rgba(212,74,74,.15);color:var(--red);border:1px solid var(--red)}\n.state-red .dot{background:var(--red)}\n.state-blue{background:rgba(74,138,212,.15);color:var(--blue);border:1px solid var(--blue)}\n.state-blue .dot{background:var(--blue)}\n.state-gray{background:rgba(154,154,166,.15);color:var(--txt-s);border:1px solid var(--txt-s)}\n.state-gray .dot{background:var(--txt-s)}\n\n\/* ===== details ===== *\/\ndetails{\n  background:var(--ink-3);border:1px solid var(--line);\n  border-radius:10px;padding:11px 16px;margin:12px 0;\n  font-size:.86rem;\n}\ndetails summary{\n  cursor:pointer;font-weight:600;color:var(--gold-l);\n  list-style:none;display:flex;align-items:center;gap:8px;\n}\ndetails summary::before{\n  content:\"\u25b8\";display:inline-block;transition:transform .2s;color:var(--gold);\n}\ndetails[open] summary::before{transform:rotate(90deg)}\ndetails[open]{background:var(--ink-2)}\ndetails .inner{padding:10px 4px 0;color:var(--txt);font-size:.84rem}\ndetails .inner p,details .inner li{margin:6px 0}\n\n\/* ===== \u6807\u7b7e ===== *\/\n.tag{\n  display:inline-block;padding:3px 10px;margin:3px 4px 3px 0;\n  background:rgba(201,161,74,.10);border:1px solid var(--gold-d);\n  border-radius:999px;font-size:.72rem;color:var(--gold-l);\n}\n.tag-blue{background:rgba(74,138,212,.10);border-color:rgba(74,138,212,.5);color:var(--blue)}\n.tag-green{background:rgba(58,175,118,.10);border-color:rgba(58,175,118,.5);color:var(--green)}\n\n\/* ===== \u94fe\u63a5 ===== *\/\na{color:var(--gold-l);text-decoration:none;transition:color .2s}\na:hover{color:#fff;text-decoration:underline}\n\n\/* ===== \u5360\u6bd4\u6761 ===== *\/\n.bar-row{display:flex;align-items:center;gap:10px;margin:6px 0;font-size:.85rem}\n.bar-row .label{width:160px;color:var(--txt)}\n.bar-row .bar{flex:1;height:14px;background:var(--ink-3);border-radius:8px;overflow:hidden;position:relative}\n.bar-row .fill{height:100%;border-radius:8px;background:linear-gradient(90deg,var(--gold) 0%,var(--gold-l) 100%)}\n.bar-row .fill.ac{background:linear-gradient(90deg,#4a8ad4 0%,#7eb5e8 100%)}\n.bar-row .fill.fh{background:linear-gradient(90deg,#d44a4a 0%,#e87575 100%)}\n.bar-row .fill.fa{background:linear-gradient(90deg,#3aaf76 0%,#5fd09a 100%)}\n.bar-row .fill.wt{background:linear-gradient(90deg,#4ec5d4 0%,#7adce8 100%)}\n.bar-row .val{width:90px;text-align:right;color:var(--gold-l);font-weight:700}\n\n\/* ===== \u9875\u811a ===== *\/\n.footer{\n  background:linear-gradient(180deg,#0a0a10 0%,#16161e 100%);\n  border:1px solid var(--gold-d);border-radius:14px;\n  padding:24px 22px;margin-top:30px;font-size:.82rem;color:var(--txt-s);\n}\n.footer .brand{\n  text-align:center;font-size:1.05rem;color:var(--gold-l);\n  font-weight:700;margin-bottom:14px;letter-spacing:2px;\n}\n.footer .stores{\n  display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0;\n}\n.footer .store{\n  background:var(--ink-3);border:1px solid var(--line);\n  border-radius:10px;padding:14px;\n}\n.footer .store h4{\n  color:var(--gold-l);font-size:.92rem;margin:0 0 8px;\n  display:flex;align-items:center;gap:6px;\n}\n.footer .store .info{font-size:.8rem;color:var(--txt);margin:3px 0}\n.footer .store .info b{color:var(--gold-l)}\n.footer .sales-line{\n  margin-top:14px;padding-top:14px;\n  border-top:1px dashed var(--line);text-align:center;\n  font-size:.86rem;\n}\n.footer .sales-line b{color:var(--gold-l);font-size:.96rem}\n\n\/* ===== \u6570\u636e\u6e90 ===== *\/\n.data-source{\n  margin-top:24px;background:var(--ink-3);\n  border:1px dashed var(--gold-d);border-radius:10px;\n  padding:14px 18px;font-size:.78rem;color:var(--txt-s);\n  line-height:1.8;\n}\n.data-source strong{color:var(--gold-l)}\n\n\/* ===== \u7248\u672c\u8bb0\u5f55 ===== *\/\n.version-log{\n  background:var(--ink-3);border-radius:10px;padding:14px 18px;\n  font-size:.82rem;margin:10px 0;\n}\n.version-log .item{\n  display:flex;gap:14px;padding:6px 0;\n  border-bottom:1px dashed var(--line);\n}\n.version-log .item:last-child{border-bottom:none}\n.version-log .v-date{color:var(--gold-l);font-weight:600;width:120px;flex-shrink:0}\n.version-log .v-ver{color:var(--txt-s);width:90px;flex-shrink:0;font-size:.74rem}\n\n\/* ===== \u79fb\u52a8\u7aef \u00b7 V1.3 \u5f3a\u5236\u9879 #11 ===== *\/\n@media(max-width:820px){\n  body{font-size:14px}\n  .hero{min-height:340px;padding:36px 16px 30px}\n  .hero h1{font-size:1.25rem}\n  .hero .sub{font-size:.82rem}\n  .hero .ids{gap:6px}\n  .hero .id-chip{font-size:.68rem;padding:5px 10px}\n  .toc-grid{grid-template-columns:repeat(4,1fr);gap:5px}\n  .toc-grid a{font-size:.68rem;padding:6px 2px}\n  .wrap{padding:20px 14px 30px}\n  .sec{padding:18px 16px}\n  .sec h2{font-size:1rem}\n  .id-block .row{grid-template-columns:repeat(2,1fr)}\n  table{font-size:.78rem}\n  th,td{padding:6px 4px}\n  .footer .stores{grid-template-columns:1fr}\n  .version-log .item{flex-direction:column;gap:4px}\n  .version-log .v-date,.version-log .v-ver{width:auto}\n  .bar-row .label{width:110px;font-size:.78rem}\n  .bar-row .val{width:80px;font-size:.78rem}\n}\n<\/style>\n\n<!-- ============ \u5934\u90e8 \u00b7 \u9ed1\u5e95\u91d1\u4e3b\u9898 hero ============ -->\n<header class=\"hero\">\n  <div class=\"kicker\">LONGMAI \u00b7 CUSTOMER SUCCESS ARCHIVE \u00b7 V1.3<\/div>\n  <h1>\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66<\/h1>\n  <p class=\"sub\">\u8d1f2F-4F \u51716\u5c42\u522b\u5885 \u00b7 \u65e5\u7acb\u5c0a\u777f\u5168\u6548280+\u6c34\u6a21\u5757\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff081F-4F\uff09 + \u8212\u4eab125\u4e00\u62d6\u56db+\u4e91\u51c0\u65b0\u98ce350\uff08\u8d1f1F-\u8d1f2F\uff09\u00b7 5-6\u4eba\u5e38\u4f4f \u00b7 \u65b9\u6848\u5df2\u51fa\u5f85\u786e\u8ba4<\/p>\n  <div class=\"price-tag\">\u5408\u540c\u603b\u4ef7 \u00a5178,261 \uff5c \u8bbe\u5907\u5408\u8ba1 \uff5c \u4e0d\u542b\u9664\u6e7f\u5305\/\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1 \uff5c \u62a5\u4ef7\u6709\u6548\u671f30\u5929<\/div>\n  <div class=\"ids\">\n    <span class=\"id-chip\">\ud83d\udcc1 \u6863\u6848\u53f7 KH-2026-0383<\/span>\n    <span class=\"id-chip\">\ud83d\udccb \u65b9\u6848\u53f7 KH-2026-0383-FA01<\/span>\n    <span class=\"id-chip\">\ud83e\udd1d \u9500\u552e \u4f59\u6653\u73b2 13008113409<\/span>\n    <span class=\"id-chip\">\ud83d\udcc5 \u5efa\u6863 2026-07-26<\/span>\n    <span class=\"id-chip\">\ud83d\udc64 \u5ba2\u6237ID KH-2026-0383<\/span>\n    <span class=\"id-chip\">\ud83c\udfe0 \u6237\u578b \u522b\u5885\u00b7\u8d1f2F-4F\u00b76\u5c42<\/span>\n  <\/div>\n<\/header>\n\n<!-- ============ \u76ee\u5f55\u5bfc\u822a \u00b7 sticky ============ -->\n<nav class=\"toc-nav\">\n  <div class=\"toc-inner\">\n    <div class=\"toc-title\">\ud83d\udcd1 \u76ee\u5f55\u5bfc\u822a\uff08\u516b\u7ae0\u8282\u951a\u70b9 \u00b7 \u70b9\u51fb\u76f4\u8fbe\uff09<\/div>\n    <div class=\"toc-grid\">\n      <a href=\"#ch1\"><span class=\"n\">01<\/span>\u5ba2\u6237\u5168\u666f<\/a>\n      <a href=\"#ch2\"><span class=\"n\">02<\/span>\u9700\u6c42\u65b9\u6848<\/a>\n      <a href=\"#ch3\"><span class=\"n\">03<\/span>\u5408\u540c\u8d22\u52a1<\/a>\n      <a href=\"#ch4\"><span class=\"n\">04<\/span>\u65bd\u5de5\u4ea4\u4ed8<\/a>\n      <a href=\"#ch5\"><span class=\"n\">05<\/span>\u80fd\u8017\u8ffd\u8e2a<\/a>\n      <a href=\"#ch6\"><span class=\"n\">06<\/span>\u552e\u540e\u8d28\u4fdd<\/a>\n      <a href=\"#ch7\"><span class=\"n\">07<\/span>\u5ba2\u6237\u72b6\u6001<\/a>\n      <a href=\"#ch8\"><span class=\"n\">08<\/span>\u4f20\u627f\u6848\u4f8b<\/a>\n    <\/div>\n  <\/div>\n<\/nav>\n\n<div class=\"wrap\">\n\n<!-- ============ \u56dbID\u4e3b\u952e\u603b\u89c8 ============ -->\n<section class=\"sec\">\n  <h2>\ud83d\udd11 \u56dbID\u4e3b\u952e\uff08\u6240\u6709\u4ea7\u51fa\u6587\u6863\u7edf\u4e00\u6253\u5934 \u00b7 V1.3 \u5f3a\u5236\u9879 #1\uff09<\/h2>\n  <div class=\"id-block\">\n    <div class=\"hint\">\u4f9d\u636e\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b\u53cc\u5199\u6a21\u578b\uff1a\u6863\u6848\u5e93=\u5355\u4e00\u5ba2\u6237\u771f\u6e90\uff0c\u8d22\u52a1\u5e93=\u5355\u5411\u5206\u62e3\u955c\u50cf<\/div>\n    <div class=\"row\">\n      <div class=\"cell\">\n        <div class=\"k\">\u5ba2\u6237ID<\/div>\n        <div class=\"v\">KH-2026-0383<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u6863\u6848\u53f7<\/div>\n        <div class=\"v\">KH-2026-0383<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u5408\u540c\u53f7<\/div>\n        <div class=\"v muted\">\u5f85\u8865\uff08\u672a\u7b7e\u5355\uff09<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u65b9\u6848\u53f7<\/div>\n        <div class=\"v\">KH-2026-0383-FA01<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u6d3e\u5de5\u5355\u53f7<\/div>\n        <div class=\"v muted\">KH-2026-0383-PG\uff08\u5f85\u8865\uff09<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u9a8c\u6536\u5355\u53f7<\/div>\n        <div class=\"v muted\">KH-2026-0383-YS\uff08\u5f85\u8865\uff09<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u95e8\u5e97<\/div>\n        <div class=\"v\">\u5357\u5bcc\u68ee\u5ba2\u6237\u6210\u529f<\/div>\n      <\/div>\n      <div class=\"cell\">\n        <div class=\"k\">\u4e0b\u6b21\u8ddf\u8fdb<\/div>\n        <div class=\"v\">2026-08-05<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n  <p style=\"font-size:.78rem;color:var(--txt-s)\">\n    <span class=\"tag tag-blue\">\u8bf4\u660e<\/span> \u6d3e\u5de5\u5355\u4e0e\u9a8c\u6536\u5355\u53f7\u9075\u5faa\u300c\u5408\u540c\u53f7-PG\/-YS\u300d\u89c4\u5219\u751f\u6210\uff1b\u5f53\u524d\u5ba2\u6237\u672a\u7b7e\u5355\uff0c\u5408\u540c\u53f7\u89e6\u53d1\u540e\u81ea\u52a8\u7ea7\u8054\u8865\u9f50\u56dbID\u3002\u5ba2\u6237\u7f16\u7801\u300cXQDD\u300d= \u897f\u5357\u533a\u00b7\u5927\u5b85\uff0c\u300cXLS\u300d= \u718a\u8001\u5e08\u9996\u5b57\u6bcd\u3002\n  <\/p>\n<\/section>\n\n<!-- ============ \u7b2c\u4e00\u7ae0 \u00b7 \u5ba2\u6237\u5168\u666f ============ -->\n<section class=\"sec\" id=\"ch1\">\n  <h2>\u7b2c\u4e00\u7ae0 \u00b7 \u5ba2\u6237\u5168\u666f\uff08\u6863\u6848\u5e93\u00b7\u4fe1\u606f\u5361\u540c\u6e90\uff09<\/h2>\n\n  <h3>1.1 \u8eab\u4efd\u4fe1\u606f\uff08\u4e0d\u8131\u654f \u00b7 V1.3 \u5f3a\u5236\u9879 #5\uff09<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><th style=\"width:34%\">\u5907\u6ce8<\/th><\/tr>\n    <tr><td>\u59d3\u540d<\/td><td>\u718a\u8001\u5e08\uff08\u718a\u603b\uff09<\/td><td>\u5fc5\u586b \u2705<\/td><\/tr>\n    <tr><td>\u8054\u7cfb\u65b9\u5f0f<\/td><td>\u5f85\u786e\u8ba4\uff08\u4fe1\u606f\u5361\u5b57\u6bb5\uff09<\/td><td>\u5ba2\u6237\u5df2\u9762\u8c08\u7559\u8d44\uff0c\u7535\u8bdd\u5fae\u4fe1\u5f85\u8865 \u2705<\/td><\/tr>\n    <tr><td>\u5c0f\u533a\/\u5730\u5740<\/td><td>\u5f85\u8865\u5145\uff08\u4fe1\u606f\u5361\u4e2d\u672a\u786e\u8ba4\uff09<\/td><td>\u51fa\u65b9\u6848\u524d\u8865\u9f50 \u00b7 \u6210\u90fd\u522b\u5885\u9879\u76ee<\/td><\/tr>\n    <tr><td>\u6237\u578b<\/td><td>\u522b\u5885\uff08\u8d1f2F-4F \u51716\u5c42\uff09<\/td><td>\u5927\u5b85\u9879\u76ee \u00b7 \u591a\u5c42\u72ec\u7acb\u7a7a\u95f4<\/td><\/tr>\n    <tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>250\u33a1<\/td><td>\u5730\u6696\u6309250\u33a1\u6838\u7b97<\/td><\/tr>\n    <tr><td>\u5e38\u4f4f\u4eba\u53e3<\/td><td>5-6\u4eba<\/td><td>\u591a\u4ee3\u540c\u5802\uff0c\u542b\u5c0f\u5b69\u623f<\/td><\/tr>\n    <tr><td>\u5ba2\u6237\u7c7b\u578b<\/td><td>\u65b0\u88c5<\/td><td>\u6bdb\u576f\u9636\u6bb5\uff08\u5df2\u51fa\u65b9\u6848\uff09<\/td><\/tr>\n    <tr><td>\u5ba2\u6237\u5206\u7ea7<\/td><td>\u65b0\u5ba2<\/td><td>\u9996\u6b21\u670d\u52a1<\/td><\/tr>\n    <tr><td>\u6e20\u9053\u6765\u6e90<\/td><td><b>\u5730\u56fe<\/b>\uff08\u7ebf\u4e0a\u5730\u56fe\u67e5\u8be2\uff09<\/td><td>17\u7c7b\u95ed\u96c6\u5f52\u7c7b \u2705<\/td><\/tr>\n    <tr><td>\u9500\u552e\u987e\u95ee<\/td><td>\u4f59\u6653\u73b2<\/td><td>\u4ece\u4e1a22\u5e74<\/td><\/tr>\n    <tr><td>\u8ddf\u5355\u9636\u6bb5<\/td><td>\u65b9\u6848\u8bbe\u8ba1\u4e2d\uff08\u65b9\u6848\u5df2\u51fa\u5f85\u786e\u8ba4\uff09<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u5efa\u6863\/\u66f4\u65b0\u65e5\u671f<\/td><td>2026-07-26<\/td><td>\u2014<\/td><\/tr>\n  <\/table>\n\n  <h3>1.2 \u5ba2\u6237\u753b\u50cf\uff08\u4fe1\u606f\u5361B\u5c42\u540c\u6e90\uff09<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u6838\u5fc3\u8bc9\u6c42<\/td><td>\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355<\/td><\/tr>\n    <tr><td>\u9884\u7b97\/\u9884\u4f30\u91d1\u989d<\/td><td>\u8bbe\u5907\u603b\u4ef7\u7ea6<b>17.8\u4e07\u5143<\/b>\uff08\u4e0d\u542b\u9664\u6e7f\u5305\u9009\u914d\/\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1\uff09<\/td><\/tr>\n    <tr><td>\u9690\u6027\u7ea6\u675f<\/td><td>\u5730\u4e0b\u5ba4\u539f\u8ba1\u5212\u505a\u67dc\u6302\u673a+\u4e0d\u505a\u5730\u6696\uff0c\u9700\u8c03\u6574\u65b9\u6848<\/td><\/tr>\n    <tr><td>\u65b9\u6848\u504f\u597d<\/td><td>\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff0c\u9700\u5bf9\u6bd4\u5c0a\u777f\u5168\u6548 vs \u6c34\u5885\u9002<\/td><\/tr>\n    <tr><td>\u75db\u70b9\/\u62c5\u5fc3<\/td><td>\u5730\u4e0b\u5ba4\u6f6e\u6e7f\u6613\u53d1\u9709\u3001\u65e0\u81ea\u7136\u901a\u98ce\u3001\u67dc\u6302\u673a\u5916\u673a\u4f4d\u96be\u627e<\/td><\/tr>\n    <tr><td>\u5ba2\u6237\u539f\u8bdd\u7eaa\u8981<\/td><td>&#8220;\u8981\u6c42\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355&#8221;\uff08\u539f\u59cb\u9700\u6c42\u7eaa\u8981\u5f85\u8865\uff09<\/td><\/tr>\n    <tr><td>\u4f1a\u5458\u72b6\u6001<\/td><td>\u666e\u901a\u5ba2\u6237\uff08active\uff09<\/td><\/tr>\n  <\/table>\n\n  <h3>1.3 \u5ba2\u6237\u6210\u529f\u76ee\u6807\uff08\u91cf\u5316\u53ef\u9a8c\u8bc1 \u00b7 \u22644\u6761\uff09<\/h3>\n  <div class=\"box-gold\">\n    <p><b>\u2460 \u8212\u9002\u5065\u5eb7+\u7a33\u5b9a\u7ef4\u62a4<\/b> \u2014\u2014 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u89e3\u51b3\u590f\u5b63\u51b7\/\u51ac\u5b63\u6696\/\u6885\u96e8\u5b63\u9664\u6e7f\u4e09\u5927\u521a\u9700\uff0c\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\uff0c<b>\u65e0\u6f0f\u6c34\u98ce\u9669<\/b><\/p>\n    <p><b>\u2461 \u5730\u4e0b\u5ba4\u9664\u6e7f+\u65b0\u98ce<\/b> \u2014\u2014 \u8212\u4eab125\u4e00\u62d6\u56db+\u4f4e\u6e29\u9664\u6e7f\u5305\uff08\u6700\u4f4e10\u2103\u53ef\u9664\u6e7f\uff09+ \u4e91\u51c0\u65b0\u98ce350\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362\uff0c<b>\u6210\u90fd\u6885\u96e8\u5b63\u521a\u9700<\/b><\/p>\n    <p><b>\u2462 \u9884\u7b97\u63a7\u5236<\/b> \u2014\u2014 \u8bbe\u5907\u603b\u4ef7\u9501\u5b9a \u00a5178,261\uff08\u4e0d\u542b\u9664\u6e7f\u5305\/\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1\uff09\uff0c\u5206\u7cfb\u7edf\u914d\u7f6e\u907f\u514d\u8d85\u652f<\/p>\n    <p><b>\u2463 \u957f\u671f\u8fd0\u884c\u8d39\u4f4e<\/b> \u2014\u2014 \u5929\u6c1f\u5730\u6c34COP\u22653.0\uff0c\u6bd4\u71c3\u6c14\u7089\u770130%+\uff0c20\u5e74\u8fd0\u884c\u8d39\u9884\u8ba1\u8282\u7701\u00a55-7\u4e07<\/p>\n  <\/div>\n<\/section>\n\n<!-- ============ \u7b2c\u4e8c\u7ae0 \u00b7 \u9700\u6c42\u8bca\u65ad\u4e0e\u65b9\u6848 ============ -->\n<section class=\"sec\" id=\"ch2\">\n  <h2>\u7b2c\u4e8c\u7ae0 \u00b7 \u9700\u6c42\u8bca\u65ad\u4e0e\u65b9\u6848\uff08\u552e\u524d\u6bb5\u00b7\u4fe1\u606f\u5361C\u5c42\u540c\u6e90\uff09<\/h2>\n\n  <h3>2.1 \u9700\u6c42\u8bca\u65ad\u6458\u8981<\/h3>\n  <table>\n    <tr><th>\u5ba2\u6237\u539f\u8bdd\/\u8868\u73b0<\/th><th>\u8bca\u65ad\u7ed3\u8bba<\/th><th>\u89c4\u8303\/\u6807\u51c6\u5f15\u7528<\/th><\/tr>\n    <tr><td>&#8220;\u8212\u9002\u5065\u5eb7\u3001\u8282\u80fd\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355&#8221;<\/td><td>\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff1a\u6c1f\u673a\u94dc\u7ba1\u6807\u51c6\u5316+\u6c34\u6a21\u5757\u5730\u6696\uff0cCOP\u22653.0\u8282\u80fd\uff0c\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><td>\u300a\u65b9\u6848\u6a21\u677f\u6846\u67b6V1.5\u300b\u5929\u6c1f\u5730\u6c34\u6863\u4f4d\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u5730\u4e0b\u5ba4\u539f\u8ba1\u5212\u67dc\u6302\u673a+\u4e0d\u505a\u5730\u6696<\/td><td>\u67dc\u6302\u673a\u5916\u673a\u4f4d\u96be\u627e+\u7ba1\u8def\u8d70\u7ebf\u56f0\u96be\uff0c<b>\u6539\u7528\u8212\u4eab\u4e00\u62d6\u56db+\u4f4e\u6e29\u9664\u6e7f\u5305+\u4e91\u51c0\u65b0\u98ce<\/b><\/td><td>GB 50736-2012 \u5236\u51b7\u8d1f\u8377 + \u6210\u90fd\u6885\u96e8\u5b63\u9664\u6e7f\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u6210\u90fd\u6f6e\u6e7f\uff0c\u6885\u96e8\u5b63\u5730\u4e0b\u5ba4\u6613\u53d1\u9709<\/td><td>\u8212\u4eab\u5185\u673a\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\uff08\u6700\u4f4e10\u2103\u53ef\u9664\u6e7f\uff09+ \u4e91\u51c0\u65b0\u98ce350\u901a\u98ce\u6362\u6c14<\/td><td>\u6210\u90fd\u6c14\u5019\u5bf9\u6807 \u00b7 \u5730\u4e0b\u5ba4\u9632\u9709\u8bbe\u8ba1<\/td><\/tr>\n    <tr><td>1F-4F\u9700\u8981\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696<\/td><td>\u5c0a\u777f\u5168\u6548280+\u6c34\u6a21\u5757280\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff0c\u5236\u51b7\u5feb+\u5730\u6696\u5747\u5300<\/td><td>\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b\u4e8c\u8054\u4f9b\u8bbe\u8ba1\u89c4\u8303<\/td><\/tr>\n    <tr><td>\u957f\u671f\u4f7f\u7528\u5e0c\u671b\u8fd0\u884c\u8d39\u7528\u4f4e<\/td><td>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u5730\u6696COP\u22653.0\uff0c\u6bd4\u71c3\u6c14\u7089\u770130%+\uff0c20\u5e74\u8fd0\u884c\u8d39\u7701\u00a55-7\u4e07<\/td><td>\u300a\u65b9\u6848\u6a21\u677f\u6846\u67b6V1.5\u300b\u8282\u80fd\u578b\u914d\u7f6e\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u9700\u8981\u5bf9\u6bd4\u5c0a\u777f\u5168\u6548 vs \u6c34\u5885\u9002<\/td><td>\u5c0a\u777f\u5168\u6548\u5728\u5929\u6c1f\u5730\u6c34\/COP\/\u4e0d\u964d\u6e29\u9664\u6e7f\/PE\u51c0\u5316\/\u7ef4\u62a4\u591a\u7ef4\u5ea6\u80dc\u51fa<\/td><td>\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66\u300b\u00a7\u4e09<\/td><\/tr>\n  <\/table>\n\n  <h3>2.2 \u9009\u5b9a\u65b9\u6848\uff08V1.3 \u5f3a\u5236\u9879 #4 \u00b7 \u65b9\u6848URL + GEO\u6848\u4f8bURL\u5e76\u5217\uff09<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td><b>\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b<\/b>\uff08\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u00b7\u522b\u5885\u53cc\u7cfb\u7edf\uff09<\/td><\/tr>\n    <tr><td>\u70ed\u6e90<\/td><td>\u65e5\u7acb\u5c0a\u777f\u5168\u6548280 <b>RAS-280FSXPNY5Q\uff0828.0kW\uff09<\/b> + \u6c34\u6a21\u5757 <b>RWMG-280FWNZ1Q<\/b>\uff08\u9002\u914d280\uff09<\/td><\/tr>\n    <tr><td>\u8f93\u914d<\/td><td>\u4f1f\u661fF-PPRCT\u4e3b\u7ba1 + De20\u76d8\u7ba1\uff08\u4f1f\u661f\u963b\u6c27\u7ba1\uff09+ \u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236<\/td><\/tr>\n    <tr><td>\u672b\u7aef<\/td><td>8\u53f0\u51c0\u5316\u5185\u673a\uff08RPIZ-40\/45\/71\u4e24\u7ba1\u5236\u51c0\u5316 + RPIZ-25\/36\/40\/56\u4e09\u7ba1\u5236 + RCIS-25\u536b\u6d74\u4e13\u7528\uff09<\/td><\/tr>\n    <tr><td>\u63a7\u5236<\/td><td>\u65e5\u7acb\u6c34\u6e29\u63a7\u5236\u5668 + \u66fc\u745e\u5fb7\u7535\u70ed\u6267\u884c\u5668<\/td><\/tr>\n    <tr><td>\u5730\u4e0b\u5ba4\u8865\u5145<\/td><td>\u8212\u4eab125\u4e00\u62d6\u56db <b>RAS-125HRNAQ\uff0812.5kW\uff09<\/b> + \u4e91\u51c0KPI-3521Q3A\/F\u65b0\u98ce350\uff08\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362\uff09<\/td><\/tr>\n    <tr><td>\u65b9\u6848\u7f16\u53f7<\/td><td><b>KH-2026-0383-FA01<\/b><\/td><\/tr>\n    <tr>\n      <td>\u65b9\u6848URL<\/td>\n      <td><a href=\"https:\/\/longmai-nt.com\/?page_id=7224\" target=\"_blank\">https:\/\/longmai-nt.com\/?page_id=7224<\/a><\/td>\n    <\/tr>\n    <tr>\n      <td>GEO\u6848\u4f8bURL<\/td>\n      <td><span class=\"tag\" style=\"background:rgba(232,160,53,.10);border-color:var(--warn);color:var(--warn)\">\u23f3 \u5f85\u8865<\/span> \uff08\u9996\u5355\u4ea4\u4ed8\u540e\u7531GEO\u5c0f\u7ec4\u53d1\u5e03\u522b\u5885\u5927\u5b85\u00b7\u5730\u4e0b\u5ba4\u9664\u6e7f\u00b7\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u6848\u4f8b\u9875\uff09<\/td>\n    <\/tr>\n  <\/table>\n\n  <h3>2.3 \u65b9\u6848\u8bda\u5b9e\u62ab\u9732\uff08V1.3 \u00b7 \u22653\u6761\uff09<\/h3>\n  <div class=\"box-red\">\n    <p>\u26a0 <b>\u2460 \u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\u4ef7\u683c\u5f85\u786e\u8ba4<\/b> \u2014\u2014 4\u53f0\u8212\u4eab\u5185\u673a\u00d7\u4f4e\u6e29\u9664\u6e7f\u5305\u5355\u4ef7\u672a\u6700\u7ec8\u6572\u5b9a\uff0c\u672a\u8ba1\u5165\u5408\u540c\u603b\u4ef7 \u00a5178,261\uff08\u9996\u5355\u7b7e\u524d\u5fc5\u8865\u9f50\uff09<\/p>\n    <p>\u26a0 <b>\u2461 \u4e0d\u542b\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1<\/b> \u2014\u2014 \u5b9e\u9645\u7b7e\u5355\u65f6\u6309\u73b0\u573a\u6761\u4ef6\u6838\u7b97\uff08\u9ad8\u5c42\u540a\u88c5\/\u5916\u673a\u8fdc\u7a0b\u7b49\uff09\uff0c\u7a0e\u91d1\u6309\u5b9e\u9645\u5f00\u7968\u7c7b\u578b\u53e6\u8ba1<\/p>\n    <p>\u26a0 <b>\u2462 \u62a5\u4ef7\u6709\u6548\u671f30\u5929<\/b> \u2014\u2014 \u81ea2026-07-26\u8d77\u7b97\uff0c\u903e\u671f\u9700\u91cd\u65b0\u6838\u7b97\u4ef7\u683c\uff08\u4ea7\u54c1\u5e93V5.0\u6709\u8c03\u4ef7\u53ef\u80fd\uff09<\/p>\n    <p>\u26a0 <b>\u2463 \u5730\u4e0b\u5ba4\u539f\u8ba1\u5212\u67dc\u6302\u673a+\u4e0d\u505a\u5730\u6696\u7684\u65b9\u6848\u5df2\u8c03\u6574<\/b> \u2014\u2014 \u73b0\u8c03\u6574\u4e3a\u8212\u4eab\u4e00\u62d6\u56db+\u4f4e\u6e29\u9664\u6e7f\u5305+\u4e91\u51c0\u65b0\u98ce\uff0c\u539f\u67dc\u6302\u673a\u5916\u673a\u4f4d\u5047\u8bbe\u4e0d\u518d\u6210\u7acb<\/p>\n  <\/div>\n\n  <h3>2.4 \u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757 vs \u6c34\u5885\u9002\u4e8c\u8054\u4f9b \u00b7 \u51b3\u7b56\u4f9d\u636e<\/h3>\n  <table>\n    <tr><th style=\"width:30%\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u63a8\u8350 \u2705\uff09<\/th><th>\u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th>\u7ed3\u8bba<\/th><\/tr>\n    <tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td>\u5929\u6c1f\u5730\u6c34<\/td><td>\u5929\u6c34\u5730\u6c34<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u5236\u51b7\u4f53\u9a8c<\/td><td>\u5236\u51b7\u5feb\uff0c\u51fa\u98ce7-12\u2103\uff0c\u4e09\u7ba1\u5236\u4e0d\u964d\u6e29\u9664\u6e7f<\/td><td>\u51fa\u98ce\u67d4\u548c15-20\u2103\uff0c\u9664\u6e7f\u80fd\u529b\u5f31<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>\u5236\u70ed\u4f53\u9a8c<\/td><td>\u5730\u6696\u5747\u5300\u4f9b\u70ed\uff0c\u8865\u6c14\u589e\u7113-25\u2103\u7a33\u5b9a\u8fd0\u884c<\/td><td>\u5730\u6696\u5747\u5300\u4f9b\u70ed\uff0c\u51fa\u6c34\u6e29\u5ea6\u8303\u56f4\u66f4\u5bbd<\/td><td>\u57fa\u672c\u6301\u5e73<\/td><\/tr>\n    <tr><td>\u9664\u6e7f\u80fd\u529b<\/td><td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u9664\u6e7f\u91cf175L\/\u5929<\/td><td>\u9664\u6e7f\u5f31\uff0c\u72ec\u7acb\u9664\u6e7f\u9700\u9009\u914d<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>\u7a7a\u6c14\u51c0\u5316<\/td><td>\u6807\u914dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff0cPM2.5\u53bb\u9664\u738799%<\/td><td>\u51c0\u5316\u80fd\u529b\u5f31\uff0c\u9700\u9009\u914d<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>\u81ea\u6e05\u6d01<\/td><td>\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><td>\u9700\u4eba\u5de5\u6e05\u6d17\u8fc7\u6ee4\u5668<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>\u5b89\u88c5\u590d\u6742\u5ea6<\/td><td>\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\uff0c\u6548\u7387\u9ad8<\/td><td>\u6c34\u7ba1\u9700\u6c34\u529b\u5e73\u8861\uff0c\u8981\u6c42\u6781\u9ad8<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/td><td>\u6c1f\u7cfb\u7edf\u6210\u719f\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669<\/td><td>\u6c34\u7ba1\u63a5\u5934\u591a\uff0c\u6f0f\u6c34\u98ce\u9669\u9ad8<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>\u7ef4\u62a4\u7ef4\u4fee<\/td><td>\u81ea\u6e05\u6d01\u51cf\u5c11\u4eba\u5de5\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef<\/td><td>\u9700\u5b9a\u671f\u6e05\u6d17\u8fc7\u6ee4\u5668\u3001\u9664\u57a2<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n    <tr><td>20\u5e74\u8fd0\u7ef4\u603b\u6295\u5165<\/td><td>\u6545\u969c\u5c11\uff0c\u7ef4\u4fdd\u8d39\u7528\u4f4e<\/td><td>\u7ef4\u4fdd\u8d39\u7528\u9ad8\uff0c\u6f5c\u5728\u98ce\u9669\u5927<\/td><td><b>\u5c0a\u777f\u4f18<\/b><\/td><\/tr>\n  <\/table>\n\n  <h3>2.5 \u8bbe\u5907\u914d\u7f6e\u603b\u89c8\uff08\u5360\u6bd4\u53ef\u89c6\u5316\uff09<\/h3>\n  <div class=\"bar-row\">\n    <span class=\"label\">\ud83c\udfe0 \u4e3b\u673a+\u6c34\u6a21\u5757\uff08\u5c0a\u777f280\uff09<\/span>\n    <span class=\"bar\"><span class=\"fill ac\" style=\"width:24.4%\"><\/span><\/span>\n    <span class=\"val\">\u00a543,495 \u00b7 24.4%<\/span>\n  <\/div>\n  <div class=\"bar-row\">\n    <span class=\"label\">\ud83c\udf2c \u5ba4\u5185\u673a 8\u53f0\uff08\u51c0\u5316+\u4e09\u7ba1\u5236\uff09<\/span>\n    <span class=\"bar\"><span class=\"fill\" style=\"width:29.1%\"><\/span><\/span>\n    <span class=\"val\">\u00a551,956 \u00b7 29.1%<\/span>\n  <\/div>\n  <div class=\"bar-row\">\n    <span class=\"label\">\ud83d\udd25 \u5730\u6696\u7cfb\u7edf\uff08\u4f1f\u661f\u963b\u6c27250\u33a1\uff09<\/span>\n    <span class=\"bar\"><span class=\"fill fh\" style=\"width:25.1%\"><\/span><\/span>\n    <span class=\"val\">\u00a544,750 \u00b7 25.1%<\/span>\n  <\/div>\n  <div class=\"bar-row\">\n    <span class=\"label\">\u2744 \u8212\u4eab\u4e00\u62d6\u56db+\u65b0\u98ce\uff08\u5730\u4e0b\u5ba4\uff09<\/span>\n    <span class=\"bar\"><span class=\"fill fa\" style=\"width:21.4%\"><\/span><\/span>\n    <span class=\"val\">\u00a538,060 \u00b7 21.4%<\/span>\n  <\/div>\n  <div class=\"bar-row\" style=\"margin-top:12px;border-top:1px dashed var(--line);padding-top:10px\">\n    <span class=\"label\" style=\"color:var(--gold-l);font-weight:700\">\u5408\u8ba1<\/span>\n    <span class=\"bar\"><\/span>\n    <span class=\"val\" style=\"color:var(--gold-l);font-size:1rem\">\u00a5178,261<\/span>\n  <\/div>\n<\/section>\n\n<!-- ============ \u7b2c\u4e09\u7ae0 \u00b7 \u5408\u540c\u4e0e\u8d22\u52a1 ============ -->\n<section class=\"sec\" id=\"ch3\">\n  <h2>\u7b2c\u4e09\u7ae0 \u00b7 \u5408\u540c\u4e0e\u8d22\u52a1\uff08\u7b7e\u5355\u6bb5\uff09<\/h2>\n\n  <h3>3.1 \u5408\u540c\u4fe1\u606f<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u5408\u540c\u53f7<\/td><td><span class=\"tag\" style=\"background:rgba(232,160,53,.10);border-color:var(--warn);color:var(--warn)\">\u23f3 \u5f85\u8865\uff08\u672a\u7b7e\u5355\uff09<\/span><\/td><\/tr>\n    <tr><td>\u7b7e\u5355\u65e5\u671f<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u5408\u540c\u603b\u91d1\u989d<\/td><td><b>\u00a5178,261<\/b>\uff08\u8bbe\u5907\u5408\u8ba1\uff0c\u4e0d\u542b\u9009\u914d\u9664\u6e7f\u5305\u00d74\/\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1\uff09<\/td><\/tr>\n    <tr><td>\u9009\u914d<\/td><td>\u4f4e\u6e29\u9664\u6e7f\u5305 \u00d7 4\u53f0\uff08\u4ef7\u683c\u5f85\u786e\u8ba4\uff09<\/td><\/tr>\n    <tr><td>\u9996\u4ed8\u5df2\u6536<\/td><td>\u00a50\uff08\u672a\u7b7e\u5355\uff09<\/td><\/tr>\n    <tr><td>\u56de\u6b3e\u72b6\u6001<\/td><td><span class=\"state-chip state-yellow\"><span class=\"dot\"><\/span>\u672a\u7b7e\u5355 \u00b7 \u65b9\u6848\u5df2\u51fa\u5f85\u786e\u8ba4<\/span><\/td><\/tr>\n    <tr><td>\u5176\u4ed6\u7ea6\u5b9a<\/td><td>\u62a5\u4ef7\u6709\u6548\u671f30\u5929\uff082026-07-26\u8d77\u7b97\uff09\uff0c\u4ee5\u6700\u7ec8\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6<\/td><\/tr>\n  <\/table>\n\n  <h3>3.2 \u8bbe\u5907\u660e\u7ec6\uff08\u7ad6\u6392\u7a84\u8868 \u00b7 V1.3 \u5f3a\u5236\u9879\uff09<\/h3>\n\n  <h4>\u2744 A. \u8212\u4eab\u4e00\u62d6\u56db + \u4e91\u51c0\u65b0\u98ce\uff08\u8d1f1F-\u8d1f2F\uff09\u00a538,060\uff08\u536021.4%\u00b7\u4e0d\u542b\u9664\u6e7f\u5305\uff09<\/h4>\n  <table>\n    <tr><th>\u9879\u76ee<\/th><th>\u54c1\u724c<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u673a<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab RAS-125HRNAQ\uff0812.5kW\uff09<\/td><td>1\u53f0<\/td><\/tr>\n    <tr><td>\u5185\u673a\u00b7\u8d1f\u4e8c\u697c\u5165\u6237<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab RPIZ-36<\/td><td>1\u53f0<\/td><\/tr>\n    <tr><td>\u5185\u673a\u00b7\u8d1f\u4e8c\u697c\u591a\u529f\u80fd<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab RPIZ-71<\/td><td>1\u53f0<\/td><\/tr>\n    <tr><td>\u5185\u673a\u00b7\u8d1f\u4e00\u697c\u5a31\u4e50\u533a<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab RPIZ-22<\/td><td>1\u53f0<\/td><\/tr>\n    <tr><td>\u5185\u673a\u00b7\u8d1f\u4e00\u697c\u5ba2\u623f<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab RPIZ-22<\/td><td>1\u53f0<\/td><\/tr>\n    <tr><td>\u9009\u914d\u00b7\u4f4e\u6e29\u9664\u6e7f\u5305<\/td><td>\u65e5\u7acb<\/td><td>\u00d74\uff08\u6700\u4f4e10\u2103\u53ef\u72ec\u7acb\u9664\u6e7f\uff09<\/td><td>4\u4e2a<\/td><\/tr>\n    <tr><td>\u65b0\u98ce<\/td><td>\u65e5\u7acb<\/td><td>\u4e91\u51c0 KPI-3521Q3A\/F\uff08\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362 350m\u00b3\/h\uff09<\/td><td>1\u53f0<\/td><\/tr>\n    <tfoot><tr><td colspan=\"3\">\u8212\u4eab\u7cfb\u7edf\u5c0f\u8ba1\uff08\u4e0d\u542b\u9664\u6e7f\u5305\uff09<\/td><td>\u00a538,060<\/td><\/tr><\/tfoot>\n  <\/table>\n  <div class=\"box-green\">\n    \u2705 <b>\u8fde\u63a5\u7387\u6821\u6838\uff1a<\/b> (3.6 + 7.1 + 2.2 + 2.2) = 15.1kW \u5185\u673a\u603b\u5408 \u00f7 12.5kW \u5916\u673a\u5bb9\u91cf = <b>120.8%<\/b>\uff08\u7ea6121%\uff09\uff0c\u4f4d\u4e8e\u65e5\u7acb\u89c4\u830390-130%\u5408\u89c4\u533a\u95f4\u5185\n  <\/div>\n\n  <h4>\ud83c\udfe0 B. \u5c0a\u777f\u5168\u6548280 + \u6c34\u6a21\u5757\uff081F-4F\uff09\u00a543,495\uff08\u536024.4%\uff09<\/h4>\n  <table>\n    <tr><th>\u9879\u76ee<\/th><th>\u54c1\u724c<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr>\n    <tr><td>\u5ba4\u5916\u673a<\/td><td>\u65e5\u7acb\u5c0a\u777f\u5168\u6548<\/td><td>RAS-280FSXPNY5Q\uff0828.0kW\uff09<\/td><td>1\u53f0<\/td><\/tr>\n    <tr><td>\u6c34\u6a21\u5757<\/td><td>\u65e5\u7acb<\/td><td>RWMG-280FWNZ1Q\uff08\u9002\u914d280\uff09<\/td><td>1\u53f0<\/td><\/tr>\n    <tfoot><tr><td colspan=\"3\">\u4e3b\u673a+\u6c34\u6a21\u5757\u5c0f\u8ba1<\/td><td>\u00a543,495<\/td><\/tr><\/tfoot>\n  <\/table>\n\n  <h4>\ud83c\udf2c C. \u5ba4\u5185\u673a 8\u53f0\uff08\u5c0a\u777f\u51c0\u5316+\u4e09\u7ba1\u5236+\u536b\u6d74\uff09\u00a551,956\uff08\u536029.1%\uff09<\/h4>\n  <table>\n    <tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u7c7b\u578b<\/th><\/tr>\n    <tr><td>1F<\/td><td>\u5ba2\u5385<\/td><td>RPIZ-40FSVNZ1QD\/PC<\/td><td>4.0kW<\/td><td>\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>1F<\/td><td>\u9910\u5385<\/td><td>RPIZ-45FSVNZ1QD\/PC<\/td><td>4.5kW<\/td><td>\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u8336\u5ba4<\/td><td>RPIZ-71FSVNZ1QD\/PC<\/td><td>7.1kW<\/td><td>\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u5c0f\u5b69\u623f<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>3.6kW<\/td><td>\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a<\/td><\/tr>\n    <tr><td>3F<\/td><td>\u4e3b\u5367<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4.0kW<\/td><td>\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a<\/td><\/tr>\n    <tr><td>3F<\/td><td>\u4e66\u623f<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2.5kW<\/td><td>\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u4e3b\u5367<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>5.6kW<\/td><td>\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u4e3b\u536b<\/td><td>RCIS-25FSWNQD<\/td><td>2.5kW<\/td><td>\u536b\u6d74\u4e13\u7528\u7a7a\u8c03<\/td><\/tr>\n    <tfoot><tr><td colspan=\"4\">\u5ba4\u5185\u673a\u5c0f\u8ba1\uff084.0+4.5+7.1+3.6+4.0+2.5+5.6+2.5 = 33.8kW\uff09<\/td><td>\u00a551,956<\/td><\/tr><\/tfoot>\n  <\/table>\n  <div class=\"box-green\">\n    \u2705 <b>\u8fde\u63a5\u7387\u6821\u6838\uff1a<\/b> 33.8kW \u5185\u673a\u603b\u5408 \u00f7 28.0kW \u5916\u673a\u5bb9\u91cf = <b>120.7%<\/b>\uff08\u7ea6121%\uff09\uff0c\u4f4d\u4e8e\u65e5\u7acb\u89c4\u830390-130%\u5408\u89c4\u533a\u95f4\u5185\n  <\/div>\n\n  <h4>\ud83d\udd25 D. \u5730\u6696\u7cfb\u7edf\uff08\u4f1f\u661f\u963b\u6c27+\u66fc\u745e\u5fb7\u8054\u52a8\uff09\u00a544,750\uff08\u536025.1%\uff09<\/h4>\n  <table>\n    <tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7<\/th><th>\u9762\u79ef<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8<\/td><td>De32\u4e3b\u7ba1+De20\u76d8\u7ba1\/\u4f1f\u661f\u963b\u6c27\u7ba1\/\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236<\/td><td>179\u5143\/\u33a1<\/td><td>250\u33a1<\/td><td>\u00a544,750<\/td><\/tr>\n    <tfoot><tr><td colspan=\"4\">\u5730\u6696\u7cfb\u7edf\u5408\u8ba1<\/td><td>\u00a544,750<\/td><\/tr><\/tfoot>\n  <\/table>\n\n  <h3>3.3 \u8bbe\u5907\u603b\u4ef7\u6c47\u603b\uff08\u5360\u6bd4\u53ef\u89c6\u5316\uff09<\/h3>\n  <table>\n    <tr><th>\u7cfb\u7edf<\/th><th>\u91d1\u989d\uff08\u5143\uff09<\/th><th>\u5360\u6bd4<\/th><th>\u5360\u6bd4\u6761<\/th><\/tr>\n    <tr>\n      <td>\u2744 \u8212\u4eab\u4e00\u62d6\u56db+\u4e91\u51c0\u65b0\u98ce\uff08\u5730\u4e0b\u5ba4\uff09<\/td>\n      <td>\u00a538,060<\/td>\n      <td>21.4%<\/td>\n      <td><span style=\"display:inline-block;width:21%;height:10px;background:linear-gradient(90deg,#3aaf76,#5fd09a);border-radius:5px\"><\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\ud83c\udfe0 \u5c0a\u777f\u5168\u6548280+\u6c34\u6a21\u5757\uff08\u4e3b\u673a\uff09<\/td>\n      <td>\u00a543,495<\/td>\n      <td>24.4%<\/td>\n      <td><span style=\"display:inline-block;width:24%;height:10px;background:linear-gradient(90deg,#4a8ad4,#7eb5e8);border-radius:5px\"><\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\ud83c\udf2c \u5ba4\u5185\u673a8\u53f0\uff08\u51c0\u5316+\u4e09\u7ba1\u5236+\u536b\u6d74\uff09<\/td>\n      <td>\u00a551,956<\/td>\n      <td>29.1%<\/td>\n      <td><span style=\"display:inline-block;width:29%;height:10px;background:linear-gradient(90deg,#c9a14a,#e8c97e);border-radius:5px\"><\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\ud83d\udd25 \u5730\u6696\u7cfb\u7edf\uff08\u4f1f\u661f\u963b\u6c27250\u33a1\uff09<\/td>\n      <td>\u00a544,750<\/td>\n      <td>25.1%<\/td>\n      <td><span style=\"display:inline-block;width:25%;height:10px;background:linear-gradient(90deg,#d44a4a,#e87575);border-radius:5px\"><\/span><\/td>\n    <\/tr>\n    <tfoot>\n      <tr><td><b>\u8bbe\u5907\u5408\u8ba1<\/b><\/td><td><b>\u00a5178,261<\/b><\/td><td>100%<\/td><td>\u2014<\/td><\/tr>\n      <tr><td>\u9009\u914d\u00b7\u4f4e\u6e29\u9664\u6e7f\u5305\u00d74<\/td><td>\u5f85\u786e\u8ba4<\/td><td>\u2014<\/td><td>\u672a\u8ba1\u5165\u603b\u4ef7<\/td><\/tr>\n    <\/tfoot>\n  <\/table>\n  <p style=\"font-size:.78rem;color:var(--txt-s)\">\n    <span class=\"tag tag-blue\">\u53e3\u5f84\u8bf4\u660e<\/span> \u4ee5\u4e0a\u4ef7\u683c\u4e3a<b>\u8bbe\u5907\u6298\u540e\u4ef7<\/b>\uff0c\u4e0d\u542b\u9009\u914d\u9664\u6e7f\u5305\u3001\u540a\u88c5\u8d39\u3001\u8fdc\u7a0b\u8d39\u3001\u7a0e\u91d1\u3002\u62a5\u4ef7\u6709\u6548\u671f30\u5929\uff08\u81ea2026-07-26\u8d77\u7b97\uff09\u3002\n  <\/p>\n<\/section>\n\n<!-- ============ \u7b2c\u56db\u7ae0 \u00b7 \u65bd\u5de5\u4e0e\u4ea4\u4ed8 ============ -->\n<section class=\"sec\" id=\"ch4\">\n  <h2>\u7b2c\u56db\u7ae0 \u00b7 \u65bd\u5de5\u4e0e\u4ea4\u4ed8\uff08\u5c65\u7ea6\u6bb5\uff09<\/h2>\n\n  <h3>4.1 \u65bd\u5de5\u5168\u8bb0\u5f55\uff08\u516d\u8282\u70b9 \u00b7 \u5168\u90e8\u5f85\u6392\u671f \u00b7 \u672a\u7b7e\u5355\u672a\u6d3e\u5de5\uff09<\/h3>\n  <table>\n    <tr><th>\u8282\u70b9<\/th><th>\u65e5\u671f<\/th><th>\u8d1f\u8d23\u4eba<\/th><th>\u72b6\u6001<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <tr><td>\u2460 \u73b0\u573a\u52d8\u6d4b<\/td><td>\u5f85\u6392\u671f<\/td><td>\u2014<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u23f3<\/span><\/td><td>\u5f85\u7b7e\u5355\u540e\u6d3e\u5de5\uff0c\u6d4b\u91cf\u6237\u578b\/\u5916\u673a\u4f4d\/\u7ba1\u8def\u8d70\u5411\uff08\u522b\u58856\u5c42\u9700\u9010\u5c42\u52d8\u6d4b\uff09<\/td><\/tr>\n    <tr><td>\u2461 \u6750\u6599\u8fdb\u573a<\/td><td>\u5f85\u6392\u671f<\/td><td>\u2014<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u23f3<\/span><\/td><td>\u65e5\u7acb\u4e3b\u673a+\u4f1f\u661f\u963b\u6c27\u7ba1+\u66fc\u745e\u5fb7\u8054\u52a8\uff0c\u626b\u7801\u6eaf\u6e90+\u5ba2\u6237\u7b7e\u5b57<\/td><\/tr>\n    <tr><td>\u2462 \u9690\u853d\u5de5\u7a0b<\/td><td>\u5f85\u6392\u671f<\/td><td>\u2014<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u23f3<\/span><\/td><td>\u94dc\u7ba1\u5145\u6c2e\u710a\u63a5+\u4fdd\u538b+\u5730\u6696\u76d8\u7ba1\u89c4\u8303\u94fa\u8bbe+\u6253\u538b\u8bd5\u9a8c<\/td><\/tr>\n    <tr><td>\u2463 \u8bbe\u5907\u5b89\u88c5<\/td><td>\u5f85\u6392\u671f<\/td><td>\u2014<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u23f3<\/span><\/td><td>\u5916\u673a\u540a\u88c5+\u5185\u673a\u5b9a\u4f4d+\u6c34\u6a21\u5757\u5bf9\u63a5+\u65b0\u98ce\u7ba1\u9053<\/td><\/tr>\n    <tr><td>\u2464 \u7cfb\u7edf\u8c03\u8bd5<\/td><td>\u5f85\u6392\u671f<\/td><td>\u2014<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u23f3<\/span><\/td><td>\u7cfb\u7edf\u51b2\u6d17+\u62bd\u771f\u7a7a+\u51b7\u5a92\u5145\u6ce8+\u8054\u52a8\u8c03\u8bd5+\u5730\u6696\u6d41\u91cf\u5e73\u8861<\/td><\/tr>\n    <tr><td>\u2465 \u7ae3\u5de5\u9a8c\u6536<\/td><td>\u5f85\u6392\u671f<\/td><td>\u2014<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u23f3<\/span><\/td><td>\u4e09\u65b9\u8054\u5408\u9a8c\u6536\uff0c\u51fa\u5177\u9a8c\u6536\u5355+\u5f71\u50cf\u5f52\u6863<\/td><\/tr>\n  <\/table>\n\n  <h3>4.2 \u6d3e\u5de5\u5355<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u6d3e\u5de5\u5355\u53f7<\/td><td><b>KH-2026-0383-PG<\/b>\uff08\u5f85\u8865 \u00b7 \u7b7e\u5355\u540e\u81ea\u52a8\u751f\u6210\uff09<\/td><\/tr>\n    <tr><td>\u65bd\u5de5\u73ed\u7ec4<\/td><td>\u5f85\u6d3e\u5de5\uff086\u5c42\u522b\u5885\u97002\u7ec4\u534f\u540c\uff1a\u5730\u4e0b\u5ba4\u7ec4+\u4e3b\u5c4b\u7ec4\uff09<\/td><\/tr>\n    <tr><td>\u9879\u76ee\u7ecf\u7406<\/td><td>\u5f85\u6d3e\u5de5<\/td><\/tr>\n    <tr><td>\u8ba1\u5212\u5de5\u671f<\/td><td>\u5730\u66962-3\u5929 + \u7a7a\u8c03\u6c1f\u7cfb\u7edf3-4\u5929 + \u6c34\u6a21\u57571\u5929 + \u65b0\u98ce1\u5929 + \u8c03\u8bd51\u5929 \u2248 8-10\u5de5\u4f5c\u65e5<\/td><\/tr>\n  <\/table>\n\n  <h3>4.3 \u9a8c\u6536\u5355<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u9a8c\u6536\u5355\u53f7<\/td><td><b>KH-2026-0383-YS<\/b>\uff08\u5f85\u8865 \u00b7 \u5b8c\u5de5\u89e6\u53d1\uff09<\/td><\/tr>\n    <tr><td>\u9a8c\u6536\u6807\u51c6<\/td><td>\u6c1f\u7ba1\u6253\u538b0.6-0.8MPa\u7a33\u538b\u22651h + \u5730\u6696\u6c34\u538b0.6MPa\u7a33\u538b\u22652h\uff0c\u5404\u623f\u95f4\u6e29\u5dee\u22642\u2103<\/td><\/tr>\n    <tr><td>\u5ba2\u6237\u7b7e\u5b57<\/td><td>\u5f85\u9a8c\u6536<\/td><\/tr>\n    <tr><td>\u5f71\u50cf\u5f52\u6863<\/td><td>\u9690\u853d\u5de5\u7a0b\u7167\u7247+\u9a8c\u6536\u8bb0\u5f55\u53cc\u5907\u4efd\u81f3\u9f99\u8109\u8d44\u6599\u5e93<\/td><\/tr>\n  <\/table>\n\n  <h3>4.4 \u7cbe\u5de5\u516d\u6b65\u6cd5+2\u4ea4\u4ed8\u89c4\u8303<\/h3>\n  <div class=\"box-gold\">\n    <p><b>\u516d\u6b65\u6cd5\uff1a<\/b>\u2460\u52d8\u6d4b \u2192 \u2461\u8bbe\u8ba1 \u2192 \u2462\u6750\u6599\u9a8c\u6536 \u2192 \u2463\u5b89\u88c5 \u2192 \u2464\u8c03\u8bd5 \u2192 \u2465\u9a8c\u6536<\/p>\n    <p><b>+2 \u4ea4\u4ed8\uff1a<\/b>\u4ea4\u4ed8\u6559\u5b66\uff08\u9762\u677f\/APP\/\u6c34\u6e29\u63a7\u5236\u64cd\u4f5c\u6307\u5bfc\uff0c\u5ba2\u6237\u72ec\u7acb\u64cd\u4f5c\uff09+ \u552e\u540e\u4fdd\u969c\uff08\u5efa\u6863\u56de\u8bbf\u3001\u7ec8\u8eab\u552e\u540e\u300110\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff09<\/p>\n    <p style=\"margin-top:8px;font-size:.82rem;color:var(--txt-s)\">\u4f9d\u636e\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6<\/p>\n  <\/div>\n<\/section>\n\n<!-- ============ \u7b2c\u4e94\u7ae0 \u00b7 \u80fd\u8017\u8ffd\u8e2a ============ -->\n<section class=\"sec\" id=\"ch5\">\n  <h2>\u7b2c\u4e94\u7ae0 \u00b7 \u80fd\u8017\u8ffd\u8e2a\uff08\u552e\u540e\u6bb5\u00b7\u6570\u636e\u9a71\u52a8\uff09<\/h2>\n\n  <h3>5.1 \u5e74\u5ea6\u80fd\u8017\u5bf9\u6807\uff08\u5929\u6c1f\u5730\u6c34\u522b\u5885\u57fa\u51c6\uff09<\/h3>\n  <table>\n    <tr><th style=\"width:24%\">\u7ef4\u5ea6<\/th><th>\u6570\u636e<\/th><\/tr>\n    <tr><td>\u5bf9\u6807\u57fa\u51c6\uff08100\u33a1\u91c7\u6696\u5b63\uff09<\/td><td>\u6708\u5747 \u00a5500-600\uff08\u5929\u6c1f\u5730\u6c34COP\u22653.0\u57fa\u51c6\u7ebf\uff09<\/td><\/tr>\n    <tr><td>\u672c\u6848\u89c4\u6a21\u6362\u7b97\uff08250\u33a1\uff09<\/td><td>\u6708\u5747 \u00a51,250-1,500\uff08\u91c7\u6696\u5b63\u00b75-7\u4e2a\u6708\uff09<\/td><\/tr>\n    <tr><td>\u6bd4\u71c3\u6c14\u7089\u8282\u7701<\/td><td>COP\u22653.0 vs \u71c3\u6c14\u7089COP\u22480.9\uff0c<b>\u8282\u80fd30%+<\/b><\/td><\/tr>\n    <tr><td>\u7b2c1\u5e74\u80fd\u8017\uff082026-2027\u51ac\uff09<\/td><td><span class=\"tag\" style=\"background:rgba(232,160,53,.10);border-color:var(--warn);color:var(--warn)\">\ud83d\udfe1 \u5f85\u56de\u586b<\/span>\uff08\u7cfb\u7edf\u8c03\u8bd5\u5b8c\u6210\u540e\u7b2c1\u4e2a\u91c7\u6696\u5b63\u672b\u91c7\u96c6\uff09<\/td><\/tr>\n    <tr><td>\u72b6\u6001<\/td><td><span class=\"state-chip state-yellow\"><span class=\"dot\"><\/span>\ud83d\udfe1 \u51c6\u5907\u4e2d<\/span>\uff08\u5f85\u7b7e\u5355\u2192\u65bd\u5de5\u2192\u8c03\u8bd5\u2192\u9996\u6b21\u8fd0\u884c\uff09<\/td><\/tr>\n  <\/table>\n\n  <h3>5.2 \u8282\u80fd\u4f18\u5316\u7b56\u7565<\/h3>\n  <div class=\"box-green\">\n    <p>\u2705 <b>\u4e09\u7ba1\u5236\u4e0d\u964d\u6e29\u9664\u6e7f<\/b> \u2014\u2014 \u6885\u96e8\u5b63\u9664\u6e7f\u65f6\u5ba4\u5185\u6e29\u5ea6\u4e0d\u964d\uff0c\u907f\u514d\u4f20\u7edf\u9664\u6e7f\u5e26\u6765\u7684\u4f53\u611f\u4e0d\u9002\uff08\u533a\u522b\u4e8e\u6c34\u5885\u9002\uff09<\/p>\n    <p>\u2705 <b>PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/b> \u2014\u2014 \u6807\u914dPM2.5\u53bb\u9664\u738799%\uff0c\u51cf\u5c11\u5ba4\u5185\u5faa\u73af\u51c0\u5316\u80fd\u8017<\/p>\n    <p>\u2705 <b>\u9ad8\u6e29\u6740\u83cc+\u81ea\u6e05\u6d01<\/b> \u2014\u2014 \u81ea\u52a8\u6e05\u6d01\u51cf\u5c11\u4eba\u5de5\u7ef4\u62a4+\u63d0\u5347\u6362\u70ed\u6548\u7387\uff0c\u957f\u671f\u4fdd\u6301COP\u4e0d\u8870\u51cf<\/p>\n    <p>\u2705 <b>\u8865\u6c14\u589e\u7113-25\u2103\u7a33\u5b9a\u8fd0\u884c<\/b> \u2014\u2014 \u6210\u90fd\u51ac\u5b63\u6781\u5bd2\u65f6\u6bb5\u4ecd\u80fd\u9ad8\u6548\u5236\u70ed\uff0c\u65e0\u9700\u7535\u8f85\u70ed\u989d\u5916\u8017\u80fd<\/p>\n    <p>\u2705 <b>\u5730\u6696\u5206\u5ba4\u72ec\u7acb\u63a7\u6e29<\/b> \u2014\u2014 \u66fc\u745e\u5fb7\u8054\u52a8+\u7535\u70ed\u6267\u884c\u5668\u6309\u9700\u4f9b\u70ed\uff0c\u65e0\u4eba\u623f\u95f4\u53ef\u5173\u95ed\u6216\u4f4e\u6e29\u8fd0\u884c<\/p>\n  <\/div>\n\n  <h3>5.3 20\u5e74\u80fd\u8017\u4e0e\u8282\u80fd\u5bf9\u6bd4<\/h3>\n  <table>\n    <tr><th style=\"width:40%\">\u9879\u76ee<\/th><th>\u5929\u6c1f\u5730\u6c34\uff08\u672c\u6848\uff09<\/th><th>\u71c3\u6c14\u7089+\u6c1f\u673a\uff08\u5bf9\u6807\uff09<\/th><th>\u5dee\u989d<\/th><\/tr>\n    <tr><td>\u91c7\u6696\u5b63\u5e74\u8fd0\u884c\u8d39\uff08250\u33a1\uff09<\/td><td>\u2248\u00a57,500-9,000<\/td><td>\u2248\u00a510,700-12,800<\/td><td><b>\u770130%+<\/b><\/td><\/tr>\n    <tr><td>\u5236\u51b7\u5b63\u5e74\u8fd0\u884c\u8d39<\/td><td>\u2248\u00a53,000-3,500<\/td><td>\u2248\u00a53,200-3,800<\/td><td>\u57fa\u672c\u6301\u5e73<\/td><\/tr>\n    <tr><td>\u5e74\u603b\u8fd0\u884c\u8d39<\/td><td>\u2248\u00a510,500-12,500<\/td><td>\u2248\u00a513,900-16,600<\/td><td>\u7701\u00a53,400-4,100\/\u5e74<\/td><\/tr>\n    <tr><td>20\u5e74\u7d2f\u8ba1\u8282\u7701<\/td><td>\u2014<\/td><td>\u2014<\/td><td><b>\u2248\u00a568,000-82,000<\/b><\/td><\/tr>\n  <\/table>\n<\/section>\n\n<!-- ============ \u7b2c\u516d\u7ae0 \u00b7 \u552e\u540e\u7ef4\u4fdd\u8d28\u4fdd\u627f\u8bfa ============ -->\n<section class=\"sec\" id=\"ch6\">\n  <h2>\u7b2c\u516d\u7ae0 \u00b7 \u552e\u540e\u7ef4\u4fdd\uff08\u8d28\u4fdd\u627f\u8bfa \u00b7 \u4e09\u91cd\u515c\u5e95\uff09<\/h2>\n\n  <h3>6.1 \u8d28\u4fdd\u660e\u7ec6<\/h3>\n  <table>\n    <tr><th style=\"width:40%\">\u9879\u76ee<\/th><th style=\"width:25%\">\u8d28\u4fdd\u671f<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u6574\u673a\uff09<\/td><td><b>60\u4e2a\u6708<\/b><\/td><td>\u6574\u673a\u4e94\u5e74\u8d28\u4fdd\uff0c\u5168\u56fd400\u5ba2\u670d<\/td><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u538b\u7f29\u673a\uff09<\/td><td><b>60\u4e2a\u6708<\/b><\/td><td>\u6838\u5fc3\u90e8\u4ef6\u540c\u6574\u673a\u8d28\u4fdd<\/td><\/tr>\n    <tr><td>\u4f1f\u661f\u5730\u6696\u7ba1\u9053<\/td><td><b>50\u5e74<\/b>\uff08\u4e09\u65b9\u8054\u4fdd\uff09<\/td><td>\u5382\u5bb6+\u9f99\u8109+\u4fdd\u9669\u516c\u53f8\u4e09\u91cd\u8054\u4fdd<\/td><\/tr>\n    <tr><td>\u9f99\u8109\u5b89\u88c5\u5de5\u7a0b<\/td><td><b>2\u5e74<\/b>\uff08\u9690\u853d\u5de5\u7a0b\u7ec8\u8eab\u8d1f\u8d23\uff09<\/td><td>2\u5e74\u5185\u514d\u8d39\u4e0a\u95e8\u7ef4\u4fee\uff0c\u9690\u853d\u5de5\u7a0b\u7ec8\u8eab\u6210\u672c\u4ef7\u670d\u52a1<\/td><\/tr>\n  <\/table>\n\n  <h3>6.2 \u552e\u540e\u54cd\u5e94\u627f\u8bfa<\/h3>\n  <div class=\"box-green\">\n    <p>\u2705 <b>\u7d27\u6025\u62a5\u4fee<\/b> \u2014\u2014 24\u5c0f\u65f6\u5185\u54cd\u5e94\uff08\u5982\u6f0f\u6c34\/\u4e0d\u5236\u70ed\/\u5168\u5c4b\u505c\u673a\u7b49\uff09<\/p>\n    <p>\u2705 <b>\u5e38\u89c4\u7ef4\u4fdd<\/b> \u2014\u2014 48\u5c0f\u65f6\u5185\u5b89\u6392\uff08\u5982\u6e05\u6d17\/\u8c03\u8bd5\/\u5c0f\u6545\u969c\uff09<\/p>\n    <p>\u2705 <b>\u5e74\u5ea6\u56de\u8bbf<\/b> \u2014\u2014 \u6bcf\u5e749\u6708\u91c7\u6696\u5b63\u524d\u4e3b\u52a8\u4e0a\u95e8\u5de1\u68c0\uff08\u9996\u6b21\u514d\u8d39\uff09\uff0c\u91cd\u70b9\u68c0\u67e5\u6c34\u6a21\u5757\u5730\u6696+\u9664\u6e7f\u5305\u72b6\u6001<\/p>\n    <p>\u2705 <b>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/b> \u2014\u2014 \u8282\u80fd\u6570\u636e\u8ffd\u8e2a+\u8fd0\u884c\u4f18\u5316\u5efa\u8bae\uff0cCOP\u8870\u51cf\u9884\u8b66<\/p>\n    <p>\u2705 <b>\u5927\u5b85\u4e13\u5c5e\u670d\u52a1<\/b> \u2014\u2014 6\u5c42\u522b\u5885\u6d3e\u5de5\u97002\u7ec4\u534f\u540c\uff0c\u9f99\u8109\u5927\u5b85\u9879\u76ee\u7ec4\u4f18\u5148\u6d3e\u5355<\/p>\n  <\/div>\n\n  <h3>6.3 \u7ef4\u4fdd\u8bb0\u5f55\uff08\u552e\u540e\u6bb5\u00b7\u5f85\u542f\u7528\uff09<\/h3>\n  <table>\n    <tr><th>\u65e5\u671f<\/th><th>\u7c7b\u578b<\/th><th>\u5185\u5bb9<\/th><th>\u5de5\u7a0b\u5e08<\/th><th>\u5ba2\u6237\u7b7e\u5b57<\/th><\/tr>\n    <tr><td colspan=\"5\" style=\"color:var(--txt-s);font-style:italic\">\u5f85\u7b7e\u5355\u2192\u65bd\u5de5\u2192\u8c03\u8bd5\u2192\u9996\u6b21\u8fd0\u884c\u540e\u542f\u7528\u672c\u8868<\/td><\/tr>\n  <\/table>\n<\/section>\n\n<!-- ============ \u7b2c\u4e03\u7ae0 \u00b7 \u4e94\u6001\u8272\u73af+\u5ba2\u6237\u72b6\u6001 ============ -->\n<section class=\"sec\" id=\"ch7\">\n  <h2>\u7b2c\u4e03\u7ae0 \u00b7 \u4e94\u6001\u8272\u73af + \u5ba2\u6237\u72b6\u6001<\/h2>\n\n  <h3>7.1 \u5ba2\u6237\u5206\u7c7b\u8272\u73af<\/h3>\n  <table>\n    <tr><th style=\"width:30%\">\u7ef4\u5ea6<\/th><th>\u72b6\u6001<\/th><\/tr>\n    <tr>\n      <td>\u5ba2\u6237\u5206\u7c7b<\/td>\n      <td><span class=\"state-chip state-yellow\"><span class=\"dot\"><\/span>\ud83d\udfe1 \u610f\u5411\uff08\u65b9\u6848\u5df2\u51fa\u5f85\u786e\u8ba4\uff09<\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\u8ddf\u5355\u9636\u6bb5<\/td>\n      <td><span class=\"state-chip state-blue\"><span class=\"dot\"><\/span>\ud83d\udd35 \u65b9\u6848\u8bbe\u8ba1\u4e2d<\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\u4f1a\u5458\u72b6\u6001<\/td>\n      <td><span class=\"state-chip state-green\"><span class=\"dot\"><\/span>\ud83d\udfe2 active\uff08\u6d3b\u8dc3\uff09<\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\u5408\u540c\u72b6\u6001<\/td>\n      <td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u26aa \u672a\u7b7e\u5355<\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\u7eed\u8d39\u72b6\u6001<\/td>\n      <td><span class=\"state-chip state-yellow\"><span class=\"dot\"><\/span>\ud83d\udfe1 \u5f85\u7eed\u8d39\uff08\u4f1a\u5458\u670d\u52a1\u5f85\u7ed1\u5b9a\uff09<\/span><\/td>\n    <\/tr>\n    <tr>\n      <td>\u4e0b\u6b21\u8ddf\u8fdb<\/td>\n      <td><span class=\"tag\" style=\"background:rgba(74,138,212,.10);border-color:var(--blue);color:var(--blue)\">\ud83d\udcc5 2026-08-05<\/span> \u63a8\u8fdb\u65b9\u6848\u786e\u8ba4+\u7b7e\u7ea6<\/td>\n    <\/tr>\n  <\/table>\n\n  <h3>7.2 \u5ba2\u6237\u7c7b\u578b\u6807\u7b7e<\/h3>\n  <p>\n    <span class=\"tag\">#\u5c0f\u533a\u5f85\u5b9a<\/span>\n    <span class=\"tag\">#\u718a\u8001\u5e08<\/span>\n    <span class=\"tag\">#6\u5c42\u522b\u5885<\/span>\n    <span class=\"tag\">#250\u33a1<\/span>\n    <span class=\"tag\">#\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b<\/span>\n    <span class=\"tag\">#\u5c0a\u777f\u5168\u6548280<\/span>\n    <span class=\"tag\">#\u8212\u4eab125\u4e00\u62d6\u56db<\/span>\n    <span class=\"tag\">#\u4e91\u51c0\u65b0\u98ce350<\/span>\n    <span class=\"tag\">#\u4f1f\u661f\u5730\u6696<\/span>\n    <span class=\"tag\">#\u5730\u4e0b\u5ba4\u9664\u6e7f<\/span>\n    <span class=\"tag\">#\u5730\u56fe\u6e20\u9053<\/span>\n    <span class=\"tag tag-blue\">#5-6\u4eba\u5e38\u4f4f<\/span>\n    <span class=\"tag tag-green\">#\u4f59\u6653\u73b2<\/span>\n    <span class=\"tag tag-green\">#\u65b9\u6848\u5df2\u51fa<\/span>\n  <\/p>\n<\/section>\n\n<!-- ============ \u7b2c\u516b\u7ae0 \u00b7 \u4f20\u627f\u4e0e\u6848\u4f8b ============ -->\n<section class=\"sec\" id=\"ch8\">\n  <h2>\u7b2c\u516b\u7ae0 \u00b7 \u4f20\u627f\u4e0e\u6848\u4f8b\uff08\u5ba2\u6237\u6210\u529f \u00b7 \u77e5\u8bc6\u8d44\u4ea7\u6c89\u6dc0\uff09<\/h2>\n\n  <h3>8.1 \u6848\u4f8b\u8f6c\u6362\u72b6\u6001<\/h3>\n  <table>\n    <tr><th style=\"width:30%\">\u5b57\u6bb5<\/th><th>\u5185\u5bb9<\/th><\/tr>\n    <tr><td>\u6848\u4f8b\u8f6c\u6362\u72b6\u6001<\/td><td><span class=\"state-chip state-red\"><span class=\"dot\"><\/span>\u274c \u6682\u672a\u8f6c\u6362<\/span>\uff08\u65b9\u6848\u9875\u5df2\u53d1\u5e03 page_id=7224\uff09<\/td><\/tr>\n    <tr><td>\u6848\u4f8b\u7c7b\u578b\u5019\u9009<\/td><td>\u522b\u5885\u5927\u5b85\u00b7\u5730\u4e0b\u5ba4\u9664\u6e7f\u00b7\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b<\/td><\/tr>\n    <tr><td>GEO \u6848\u4f8b URL<\/td><td><span class=\"tag\" style=\"background:rgba(232,160,53,.10);border-color:var(--warn);color:var(--warn)\">\u23f3 \u5f85\u8865<\/span> \uff08\u9996\u5355\u4ea4\u4ed8\u540e\u7531 GEO \u5c0f\u7ec4\u53d1\u5e03\u6848\u4f8b\u9875\uff0c\u5bf9\u5e94\u300aGEO\u5baa\u6cd5V6.2\u300b\u8981\u6c42\uff09<\/td><\/tr>\n  <\/table>\n\n  <h3>8.2 \u6210\u529f\u8981\u7d20\uff08\u53ef\u590d\u7528\u6c89\u6dc0\uff09<\/h3>\n  <div class=\"box-green\">\n    <p>\u2705 <b>\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u89e3\u51b3\u5730\u4e0b\u5ba4\u9664\u6e7f+\u8212\u9002+\u957f\u671f\u8282\u80fd\u4e09\u5927\u75db\u70b9<\/b> \u2014\u2014 6\u5c42\u522b\u5885\u4e00\u4f53\u5316\u65b9\u6848\uff0c\u5730\u4e0b\u5ba4\u72ec\u7acb\u8212\u4eab+1F-4F\u5c0a\u777f\u5168\u6548\uff0c\u5206\u7cfb\u7edf\u914d\u7f6e\u907f\u514d\u5355\u4e00\u7cfb\u7edf\u538b\u529b<\/p>\n    <p>\u2705 <b>\u5206\u7cfb\u7edf\u914d\u7f6e\u601d\u8def\uff08\u8212\u4eab\u5730\u4e0b\u5ba4+\u5c0a\u777f1F-4F\uff09<\/b> \u2014\u2014 \u8d1f1F-\u8d1f2F\u72ec\u7acb\u8212\u4eab\u4e00\u62d6\u56db\uff08\u5916\u673a\u4f4d\u89e3\u51b3+\u4f4e\u6e29\u9664\u6e7f\u5305\uff09+ 1F-4F\u5c0a\u777f\u5168\u6548280\u4e00\u62d6\u516b+\u6c34\u6a21\u5757\uff0c<b>\u5206\u7cfb\u7edf\u538b\u529b\u6bd4\u5355\u4e00\u5927\u7cfb\u7edf\u66f4\u4f18<\/b><\/p>\n    <p>\u2705 <b>\u5c0a\u777f\u5168\u6548 vs \u6c34\u5885\u9002 \u5b8c\u6574\u5bf9\u6bd4\u540e\u9009\u5c0a\u777f<\/b> \u2014\u2014 10\u4e2a\u7ef4\u5ea6\u5bf9\u6bd4\uff0c\u5c0a\u777f\u5728\u5929\u6c1f\u5730\u6c34\/COP\/\u4e0d\u964d\u6e29\u9664\u6e7f\/PE\u51c0\u5316\/\u7ef4\u62a4\u591a\u7ef4\u5ea6\u80dc\u51fa\uff0c<b>\u5f62\u6210\u53ef\u590d\u7528\u7684\u4e8c\u8054\u4f9b\u51b3\u7b56\u6a21\u578b<\/b><\/p>\n    <p>\u2705 <b>\u6210\u90fd\u6885\u96e8\u5b63\u521a\u9700\u00b7\u4e0d\u964d\u6e29\u9664\u6e7f<\/b> \u2014\u2014 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff08\u9664\u6e7f\u91cf175L\/\u5929\uff09\u6ee1\u8db3\u6210\u90fd\u6c14\u5019\u7279\u5f81\uff0c\u662f\u8be5\u5730\u533a\u5dee\u5f02\u5316\u5356\u70b9<\/p>\n    <p>\u2705 <b>\u539f\u65b9\u6848\u8c03\u6574\u75d5\u8ff9\u6e05\u6670<\/b> \u2014\u2014 \u5730\u4e0b\u5ba4\u539f\u8ba1\u5212\u67dc\u6302\u673a+\u4e0d\u505a\u5730\u6696\uff0c\u5df2\u8c03\u6574\u4e3a\u8212\u4eab\u4e00\u62d6\u56db+\u4f4e\u6e29\u9664\u6e7f\u5305+\u4e91\u51c0\u65b0\u98ce\uff0c<b>\u8c03\u6574\u903b\u8f91\u7559\u75d5\u4fbf\u4e8e\u590d\u76d8<\/b><\/p>\n  <\/div>\n\n  <h3>8.3 \u53ef\u6539\u8fdb\u70b9\uff08\u53e3\u7891\u524d\u7f6e\u62ab\u9732\uff09<\/h3>\n  <div class=\"box-warn\">\n    <p>\u26a0 <b>\u9009\u914d\u4f4e\u6e29\u9664\u6e7f\u5305\u4ef7\u683c\u5f85\u786e\u8ba4<\/b> \u2014\u2014 4\u53f0\u8212\u4eab\u5185\u673a\u00d7\u4f4e\u6e29\u9664\u6e7f\u5305\u5355\u4ef7\u672a\u6700\u7ec8\u6572\u5b9a\uff0c\u7b7e\u5355\u524d\u5fc5\u8865\u9f50\uff08\u5f71\u54cd\u5408\u540c\u603b\u4ef7\uff09<\/p>\n    <p>\u26a0 <b>\u62a5\u4ef730\u5929\u6709\u6548\u671f\u9700\u590d\u5ba1<\/b> \u2014\u2014 2026-07-26\u8d77\u7b97\uff0c2026-08-25\u524d\u9700\u7b7e\u5355\uff0c\u903e\u671f\u9700\u91cd\u65b0\u6838\u7b97\u4ef7\u683c\uff08\u4ea7\u54c1\u5e93V5.0\u6709\u8c03\u4ef7\u53ef\u80fd\uff09<\/p>\n    <p>\u26a0 <b>6\u5c42\u522b\u5885\u6d3e\u5de5\u9700\u63d0\u524d\u89c4\u5212<\/b> \u2014\u2014 2\u7ec4\u534f\u540c\uff08\u5730\u4e0b\u5ba4\u7ec4+\u4e3b\u5c4b\u7ec4\uff09\uff0c\u9ad8\u5cf0\u671f\u9700\u5927\u5b85\u9879\u76ee\u7ec4\u4f18\u5148\u6d3e\u5355\uff0c\u907f\u514d\u6392\u671f\u51b2\u7a81<\/p>\n    <p>\u26a0 <b>\u5ba2\u6237\u8054\u7cfb\u65b9\u5f0f\/\u5730\u5740\u9700\u8865\u9f50<\/b> \u2014\u2014 \u4fe1\u606f\u5361\u5b57\u6bb5\u672a\u786e\u8ba4\uff0c\u7b7e\u5355\u524d\u5fc5\u8865\u9f50\uff08\u5f71\u54cd\u5408\u540c\/\u6d3e\u5de5\u5355\u751f\u6210\uff09<\/p>\n  <\/div>\n\n  <h3>8.4 \u77e5\u8bc6\u6c89\u6dc0\uff08\u4f20\u627f\u624b\u518c\uff09<\/h3>\n  <table>\n    <tr><th>\u6c89\u6dc0\u9879<\/th><th>\u72b6\u6001<\/th><th>\u5f52\u6863\u4f4d\u7f6e<\/th><\/tr>\n    <tr><td>\u4fe1\u606f\u5361 JSON<\/td><td><span class=\"state-chip state-green\"><span class=\"dot\"><\/span>\u2705<\/span><\/td><td>\u9f99\u8109\u6863\u6848\u5e93 \u00b7 \u7f16\u53f7 KH-2026-0383<\/td><\/tr>\n    <tr><td>\u65b9\u6848\u4e66 Markdown<\/td><td><span class=\"state-chip state-green\"><span class=\"dot\"><\/span>\u2705<\/span><\/td><td>\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b<\/td><\/tr>\n    <tr><td>\u65b9\u6848URL<\/td><td><span class=\"state-chip state-green\"><span class=\"dot\"><\/span>\u2705<\/span><\/td><td>https:\/\/longmai-nt.com\/?page_id=7224<\/td><\/tr>\n    <tr><td>\u5ba2\u6237\u6863\u6848\u4e66 HTML<\/td><td><span class=\"state-chip state-green\"><span class=\"dot\"><\/span>\u2705<\/span><\/td><td>\u9f99\u8109\u6848\u4f8b\u5e93 \u00b7 V1.3<\/td><\/tr>\n    <tr><td>GEO \u6848\u4f8b\u9875<\/td><td><span class=\"state-chip state-red\"><span class=\"dot\"><\/span>\u274c \u5f85\u8865<\/span><\/td><td>longmai-nt.com\uff08\u9996\u5355\u4ea4\u4ed8\u540e\u53d1\u5e03\u00b7\u522b\u5885\u5927\u5b85\u6848\u4f8b\uff09<\/td><\/tr>\n    <tr><td>\u5c0f\u67d0\u4e66\/\u67d0\u97f3\u79cd\u8349<\/td><td><span class=\"state-chip state-gray\"><span class=\"dot\"><\/span>\u26aa \u5f85\u8865<\/span><\/td><td>\u4ea4\u4ed8\u540e\u7531 GEO \u5c0f\u7ec4\u8fd0\u8425<\/td><\/tr>\n  <\/table>\n<\/section>\n\n<!-- ============ \u9644\u5f55 \u00b7 \u7248\u672c\u8bb0\u5f55 ============ -->\n<section class=\"sec\">\n  <h2>\ud83d\udcdc \u9644\u5f55 \u00b7 \u6863\u6848\u4e66\u7248\u672c\u8bb0\u5f55<\/h2>\n  <div class=\"version-log\">\n    <div class=\"item\">\n      <div class=\"v-date\">2026-07-26<\/div>\n      <div class=\"v-ver\">v1.0 \u00b7 \u5efa\u6863<\/div>\n      <div>\u5ba2\u6237\u9996\u6b21\u63a5\u89e6\uff08\u5730\u56fe\u6e20\u9053\uff09\uff0c\u5efa\u7acb\u6863\u6848\u53f7 KH-2026-0383\uff0c\u5efa\u6863\u65e5\u671f 2026-07-26\uff0c\u9500\u552e \u4f59\u6653\u73b2<\/div>\n    <\/div>\n    <div class=\"item\">\n      <div class=\"v-date\">2026-07-28<\/div>\n      <div class=\"v-ver\">v1.1 \u00b7 \u4fe1\u606f\u5361<\/div>\n      <div>\u987e\u5ba2\u4fe1\u606f\u5361\uff08\u53c2\u7167\u5218\u8001\u5e08\u683c\u5f0f\uff09+ JSON\u66f4\u65b0\u7248 \u5efa\u7acb\uff0c\u6838\u5fc3\u8bc9\u6c42\u660e\u786e\u4e3a\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b+\u5730\u4e0b\u5ba4\u9664\u6e7f<\/div>\n    <\/div>\n    <div class=\"item\">\n      <div class=\"v-date\">2026-07-29<\/div>\n      <div class=\"v-ver\">v1.2 \u00b7 \u65b9\u6848\u4e66<\/div>\n      <div>\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b\u53d1\u5e03\uff0c\u65b9\u6848 URL page_id=7224\uff0c\u542b\u5c0a\u777f\u5168\u6548 vs \u6c34\u5885\u9002\u5bf9\u6bd4<\/div>\n    <\/div>\n    <div class=\"item\">\n      <div class=\"v-date\">2026-08-07<\/div>\n      <div class=\"v-ver\">v1.3 \u00b7 \u6863\u6848\u4e66<\/div>\n      <div>\u672c\u6863\u6848\u4e66V1.3\u9996\u6b21\u751f\u6210\uff0c\u4f9d\u636e\u300a\u5ba2\u6237\u6863\u6848\u4e66\u6a21\u677fv1.3\u300b\uff082026-08-05\uff09+\u300a\u65b9\u6848\u6a21\u677f\u6846\u67b6V1.5\u300b+\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b+\u300aGEO\u5baa\u6cd5V6.2\u300b<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============ AI \u9a8c\u8bc1\u6e05\u5355 \u00b7 V1.3 \u5f3a\u5236\u9879 #7 ============ -->\n<section class=\"sec\">\n  <h2>\ud83e\udd16 AI \u9a8c\u8bc1\u6e05\u5355\uff08V1.3 \u5f3a\u5236\u9879 #7 \u00b7 \u4e94\u67e5\u5fc5\u8fc7\uff09<\/h2>\n  <details open>\n    <summary>\u2460 \u578b\u53f7\u6838\u5bf9 \u2705 \u2014\u2014 \u6240\u6709\u8bbe\u5907\u578b\u53f7\u4e0e\u5382\u5bb6\u4e00\u624b\u8d44\u6599\u4e00\u81f4<\/summary>\n    <div class=\"inner\">\n      <p>\u2705 \u65e5\u7acb\u5916\u673a RAS-280FSXPNY5Q\uff0828.0kW \u5c0a\u777f\u5168\u6548\uff09\u2014\u2014 \u65e5\u7acb\u5b98\u65b9\u5c0a\u777f\u5168\u6548\u7cfb\u5217<\/p>\n      <p>\u2705 \u65e5\u7acb\u6c34\u6a21\u5757 RWMG-280FWNZ1Q \u2014\u2014 \u4e0e RAS-280 \u9002\u914d\u7684\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u6c34\u6a21\u5757<\/p>\n      <p>\u2705 \u5c0a\u777f\u5ba4\u5185\u673a RPIZ-40\/45\/71\uff08\u4e24\u7ba1\u5236\u51c0\u5316\uff09+ RPIZ-25\/36\/40\/56\uff08\u4e09\u7ba1\u5236\uff09\u2014\u2014 \u5c0a\u777f\u5168\u6548\u7cfb\u5217\u5b98\u65b9\u578b\u53f7<\/p>\n      <p>\u2705 \u536b\u6d74\u4e13\u7528 RCIS-25FSWNQD \u2014\u2014 \u65e5\u7acb\u536b\u6d74\u7a7a\u8c03\u6807\u914d<\/p>\n      <p>\u2705 \u8212\u4eab\u5916\u673a RAS-125HRNAQ\uff0812.5kW\uff09 \u2014\u2014 \u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b98\u65b9\u578b\u53f7<\/p>\n      <p>\u2705 \u8212\u4eab\u5185\u673a RPIZ-36\/71\/22\/22 \u2014\u2014 \u8212\u4eab\u7cfb\u5217\u6807\u51c6\u914d\u7f6e<\/p>\n      <p>\u2705 \u4e91\u51c0\u65b0\u98ce KPI-3521Q3A\/F\uff08\u53cc\u5411\u6d41\u5168\u70ed\u4ea4\u6362350m\u00b3\/h\uff09 \u2014\u2014 \u65e5\u7acb\u4e91\u51c0\u7cfb\u5217\u5b98\u65b9\u578b\u53f7<\/p>\n    <\/div>\n  <\/details>\n  <details>\n    <summary>\u2461 \u642d\u914d\u6838\u5bf9 \u2705 \u2014\u2014 \u7cfb\u7edf\u7ec4\u5408\u65e0\u517c\u5bb9\u6027\u51b2\u7a81<\/summary>\n    <div class=\"inner\">\n      <p>\u2705 \u5c0a\u777f\u5168\u6548 28kW \u62d6 8 \u53f0\u5185\u673a\uff084.0+4.5+7.1+3.6+4.0+2.5+5.6+2.5 = 33.8kW\uff09\u2014\u2014 \u7b26\u5408\u65e5\u7acb 90-130% \u8fde\u63a5\u7387\u89c4\u8303<\/p>\n      <p>\u2705 \u8212\u4eab 12.5kW \u62d6 4 \u53f0\u5185\u673a\uff083.6+7.1+2.2+2.2 = 15.1kW\uff09\u2014\u2014 \u7b26\u5408\u65e5\u7acb 90-130% \u8fde\u63a5\u7387\u89c4\u8303<\/p>\n      <p>\u2705 \u5c0a\u777f\u5168\u6548 \u6c1f\u673a+\u6c34\u6a21\u5757 \u2014\u2014 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff0c\u6807\u51c6\u7ec4\u5408\uff08\u533a\u522b\u4e8e\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\uff09<\/p>\n      <p>\u2705 \u8212\u4eab\u5185\u673a+\u4f4e\u6e29\u9664\u6e7f\u5305+\u4e91\u51c0\u65b0\u98ce \u2014\u2014 \u5206\u5de5\u660e\u786e\uff08\u9664\u6e7f\u9760\u5185\u673a\u9664\u6e7f\u5305\uff0c\u901a\u98ce\u6362\u6c14\u9760\u4e91\u51c0\u65b0\u98ce\uff09<\/p>\n      <p>\u2705 \u4f1f\u661fF-PPRCT\u4e3b\u7ba1+De20\u76d8\u7ba1\uff08\u4f1f\u661f\u963b\u6c27\u7ba1\uff09+\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236 \u2014\u2014 \u5730\u6696\u8f93\u914d\u6807\u51c6\u7ec4\u5408<\/p>\n      <p>\u2705 \u65e5\u7acb\u6c34\u6e29\u63a7\u5236\u5668+\u66fc\u745e\u5fb7\u7535\u70ed\u6267\u884c\u5668 \u2014\u2014 \u4e8c\u8054\u4f9b\u63a7\u5236\u6807\u51c6\u7ec4\u5408<\/p>\n    <\/div>\n  <\/details>\n  <details>\n    <summary>\u2462 \u8fde\u63a5\u7387\u6838\u5bf9 \u2705 \u2014\u2014 \u53cc\u7cfb\u7edf\u5747\u4f4d\u4e8e121%\uff0890-130%\u5408\u89c4\u8303\u56f4\uff09<\/summary>\n    <div class=\"inner\">\n      <p><b>\u8212\u4eab\u7cfb\u7edf\uff1a<\/b><\/p>\n      <p>\u8ba1\u7b97\uff1a<b>3.6 + 7.1 + 2.2 + 2.2 = 15.1kW<\/b>\uff08\u5185\u673a\u989d\u5b9a\u51b7\u91cf\u4e4b\u548c\uff09<\/p>\n      <p>\u5916\u673a\u5bb9\u91cf\uff1a<b>12.5kW<\/b>\uff08RAS-125HRNAQ\uff09<\/p>\n      <p>\u8fde\u63a5\u7387 = 15.1 \u00f7 12.5 \u00d7 100% = <b>120.8%<\/b>\uff08\u7ea6121%\uff09<\/p>\n      <p>\u65e5\u7acb\u89c4\u8303\u533a\u95f4\uff1a90% &#8211; 130% \u2705 \u5f53\u524d 120.8% \u5904\u4e8e\u4e2d\u4f4d\u504f\u4e0a\u533a\uff0c\u8fd0\u884c\u7a33\u5b9a<\/p>\n      <p><b>\u5c0a\u777f\u5168\u6548\u7cfb\u7edf\uff1a<\/b><\/p>\n      <p>\u8ba1\u7b97\uff1a<b>4.0 + 4.5 + 7.1 + 3.6 + 4.0 + 2.5 + 5.6 + 2.5 = 33.8kW<\/b>\uff08\u5185\u673a\u989d\u5b9a\u51b7\u91cf\u4e4b\u548c\uff09<\/p>\n      <p>\u5916\u673a\u5bb9\u91cf\uff1a<b>28.0kW<\/b>\uff08RAS-280FSXPNY5Q\uff09<\/p>\n      <p>\u8fde\u63a5\u7387 = 33.8 \u00f7 28.0 \u00d7 100% = <b>120.7%<\/b>\uff08\u7ea6121%\uff09<\/p>\n      <p>\u65e5\u7acb\u89c4\u8303\u533a\u95f4\uff1a90% &#8211; 130% \u2705 \u5f53\u524d 120.7% \u5904\u4e8e\u4e2d\u4f4d\u504f\u4e0a\u533a\uff0c\u8fd0\u884c\u7a33\u5b9a<\/p>\n    <\/div>\n  <\/details>\n  <details>\n    <summary>\u2463 \u4ef7\u683c\u53e3\u5f84\u6838\u5bf9 \u2705 \u2014\u2014 \u8bbe\u5907\u5206\u9879\u660e\u786e\uff0c\u603b\u4ef7 \u00a5178,261 \u4e0d\u542b\u9664\u6e7f\u5305\/\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1<\/summary>\n    <div class=\"inner\">\n      <p>\u2705 \u8212\u4eab\u7cfb\u7edf \u00a538,060\uff08\u4e0d\u542b\u9664\u6e7f\u5305\uff09\u2014\u2014 \u7cfb\u7edf\u4e00\uff1a\u5916\u673a9,330+\u5185\u673a\u00d74=16,530+\u65b0\u98ce12,200<\/p>\n      <p>\u2705 \u5c0a\u777f\u4e3b\u673a+\u6c34\u6a21\u5757 \u00a543,495 \u2014\u2014 \u7cfb\u7edf\u4e8c\uff1a\u4e3b\u673a30,170+\u6c34\u6a21\u575713,325<\/p>\n      <p>\u2705 \u5c0a\u777f\u5ba4\u5185\u673a8\u53f0 \u00a551,956 \u2014\u2014 1F\u5ba2\u99105,680+5,925+2F\u8336\u5ba46,052+\u5c0f\u5b69\u623f6,352+3F\u4e3b\u53676,352+\u4e66\u623f6,193+4F\u4e3b\u53676,714+\u4e3b\u536b8,688<\/p>\n      <p>\u2705 \u5730\u6696\u7cfb\u7edf \u00a544,750 \u2014\u2014 250\u33a1 \u00d7 179\u5143\/\u33a1\uff08\u4f1f\u661f\u963b\u6c27+\u66fc\u745e\u5fb7\u8054\u52a8\uff09<\/p>\n      <p>\u2705 \u8bbe\u5907\u5408\u8ba1 = 38,060 + 43,495 + 51,956 + 44,750 = <b>\u00a5178,261<\/b><\/p>\n      <p>\u2705 \u9009\u914d\u00b7\u4f4e\u6e29\u9664\u6e7f\u5305\u00d74 \u4ef7\u683c\u5f85\u786e\u8ba4\uff08\u672a\u8ba1\u5165\u603b\u4ef7\uff09<\/p>\n      <p>\u2705 \u4e0d\u542b\u540a\u88c5\u8d39\/\u8fdc\u7a0b\u8d39\/\u7a0e\u91d1\uff08\u5df2\u5728\u9192\u76ee\u5904\u6807\u6ce8\uff09<\/p>\n      <p>\u2705 \u62a5\u4ef7\u6709\u6548\u671f30\u5929\uff082026-07-26\u8d77\u7b97\uff09<\/p>\n    <\/div>\n  <\/details>\n  <details>\n    <summary>\u2464 \u4e0d\u7f16\u9020\u6838\u5bf9 \u2705 \u2014\u2014 \u6240\u6709\u6570\u636e\u53ef\u8ffd\u6eaf\u5230\u987e\u5ba2\u4fe1\u606f\u5361 + \u65b9\u6848\u4e66 + \u4ea7\u54c1\u4ef7\u683c\u5e93 V5.0<\/summary>\n    <div class=\"inner\">\n      <p>\u2705 \u5ba2\u6237\u4fe1\u606f\uff1a\u718a\u8001\u5e08\/\u718a\u603b\/\u522b\u5885\u8d1f2F-4F\/250\u33a1\/5-6\u4eba\/\u5730\u56fe\/\u4f59\u6653\u73b2 \u2014\u2014 \u5168\u90e8\u6765\u81ea\u4fe1\u606f\u5361 JSON<\/p>\n      <p>\u2705 \u6863\u6848\u53f7 KH-2026-0383\/\u65b9\u6848\u53f7 KH-2026-0383-FA01 \u2014\u2014 \u4e0e\u4fe1\u606f\u5361\u4e00\u81f4<\/p>\n      <p>\u2705 \u65b9\u6848URL https:\/\/longmai-nt.com\/?page_id=7224 \u2014\u2014 \u4e0e\u65b9\u6848\u4e66\u4e00\u81f4<\/p>\n      <p>\u2705 \u8bbe\u5907\u578b\u53f7\/\u4ef7\u683c \u2014\u2014 \u6765\u81ea\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b\u00a7\u56db \u900f\u660e\u62a5\u4ef7<\/p>\n      <p>\u2705 \u8fde\u63a5\u7387 121% \u53cc\u7cfb\u7edf \u2014\u2014 \u6765\u81ea\u65b9\u6848\u4e66 \u00a7\u4e00-\u00a7\u4e8c \u8bbe\u8ba1\u7ae0\u8282<\/p>\n      <p>\u2705 \u5c0a\u777f vs \u6c34\u5885\u9002 10\u7ef4\u5bf9\u6bd4 \u2014\u2014 \u6765\u81ea\u65b9\u6848\u4e66 \u00a7\u4e09 \u7efc\u5408\u5bf9\u6bd4<\/p>\n      <p>\u2705 \u5ba2\u6237\u8054\u7cfb\u65b9\u5f0f\u660e\u786e\u6807\u6ce8&#8221;\u5f85\u786e\u8ba4&#8221;\uff0c\u672a\u7f16\u9020<\/p>\n      <p>\u2705 \u5c0f\u533a\/\u5730\u5740\u660e\u786e\u6807\u6ce8&#8221;\u5f85\u8865\u5145&#8221;\uff0c\u672a\u7f16\u9020<\/p>\n      <p>\u2705 \u4e0b\u6b21\u8ddf\u8fdb\u65e5\u671f 2026-08-05 \u6765\u81ea\u4fe1\u606f\u5361 D \u5c42<\/p>\n      <p>\u2705 \u7ef4\u4fdd\u671f\uff0860\u6708\/50\u5e74\/2\u5e74\uff09\u6765\u81ea\u5382\u5bb6\u8d28\u4fdd\u6761\u6b3e+\u9f99\u8109\u552e\u540e\u627f\u8bfa<\/p>\n    <\/div>\n  <\/details>\n<\/section>\n\n<!-- ============ \u8bc1\u636e\u94fe \u00b7 V1.3 \u5f3a\u5236\u9879 #8 ============ -->\n<section class=\"sec\">\n  <h2>\ud83d\udd17 \u8bc1\u636e\u94fe\uff08V1.3 \u5f3a\u5236\u9879 #8 \u00b7 \u4e09\u94fe\u53ef\u8ffd\u6eaf\uff09<\/h2>\n\n  <details>\n    <summary>\ud83d\udcd0 \u8bc1\u636e\u94fe 1\/3 \u00b7 \u53cc\u7cfb\u7edf\u8fde\u63a5\u7387 121% \u8ba1\u7b97\u5f0f\uff08\u4f9d\u636e\u65e5\u7acb\u8bbe\u8ba1\u89c4\u8303\uff09<\/summary>\n    <div class=\"inner\">\n      <p><b>\u8ba1\u7b97\u6b65\u9aa4\uff08\u8212\u4eab\u7cfb\u7edf\uff09\uff1a<\/b><\/p>\n      <p>Step 1 \u2014 \u5185\u673a\u989d\u5b9a\u51b7\u91cf\u6c42\u548c\uff1a<\/p>\n      <p style=\"margin-left:16px\">\n        \u8d1f\u4e8c\u697c\u5165\u6237\uff1aRPIZ-36 = 3.6kW<br>\n        \u8d1f\u4e8c\u697c\u591a\u529f\u80fd\uff1aRPIZ-71 = 7.1kW<br>\n        \u8d1f\u4e00\u697c\u5a31\u4e50\u533a\uff1aRPIZ-22 = 2.2kW<br>\n        \u8d1f\u4e00\u697c\u5ba2\u623f\uff1aRPIZ-22 = 2.2kW<br>\n        <b>\u5408\u8ba1\uff1a15.1kW<\/b>\n      <\/p>\n      <p>Step 2 \u2014 \u5916\u673a\u5bb9\u91cf\uff1aRAS-125HRNAQ = <b>12.5kW<\/b><\/p>\n      <p>Step 3 \u2014 \u8fde\u63a5\u7387\u8ba1\u7b97\uff1a15.1 \u00f7 12.5 \u00d7 100% = <b>120.8%<\/b>\uff08\u7ea6121%\uff09<\/p>\n      <p><b>\u8ba1\u7b97\u6b65\u9aa4\uff08\u5c0a\u777f\u5168\u6548\u7cfb\u7edf\uff09\uff1a<\/b><\/p>\n      <p>Step 1 \u2014 \u5185\u673a\u989d\u5b9a\u51b7\u91cf\u6c42\u548c\uff1a<\/p>\n      <p style=\"margin-left:16px\">\n        1F\u5ba2\u5385\uff1aRPIZ-40 = 4.0kW<br>\n        1F\u9910\u5385\uff1aRPIZ-45 = 4.5kW<br>\n        2F\u8336\u5ba4\uff1aRPIZ-71 = 7.1kW<br>\n        2F\u5c0f\u5b69\u623f\uff1aRPIZ-36 = 3.6kW<br>\n        3F\u4e3b\u5367\uff1aRPIZ-40 = 4.0kW<br>\n        3F\u4e66\u623f\uff1aRPIZ-25 = 2.5kW<br>\n        4F\u4e3b\u5367\uff1aRPIZ-56 = 5.6kW<br>\n        4F\u4e3b\u536b\uff1aRCIS-25 = 2.5kW<br>\n        <b>\u5408\u8ba1\uff1a33.8kW<\/b>\n      <\/p>\n      <p>Step 2 \u2014 \u5916\u673a\u5bb9\u91cf\uff1aRAS-280FSXPNY5Q = <b>28.0kW<\/b><\/p>\n      <p>Step 3 \u2014 \u8fde\u63a5\u7387\u8ba1\u7b97\uff1a33.8 \u00f7 28.0 \u00d7 100% = <b>120.7%<\/b>\uff08\u7ea6121%\uff09<\/p>\n      <p>Step 4 \u2014 \u89c4\u8303\u5bf9\u7167\uff1a\u65e5\u7acb\u6c1f\u7cfb\u7edf\u89c4\u8303 90% \u2264 \u8fde\u63a5\u7387 \u2264 130%<\/p>\n      <p>Step 5 \u2014 \u7ed3\u8bba\uff1a<b>\u8212\u4eab120.8% + \u5c0a\u777f120.7% \u5747\u5904\u4e8e\u4e2d\u4f4d\u504f\u4e0a\u533a\uff0c\u8fd0\u884c\u7a33\u5b9a \u2705<\/b><\/p>\n      <p style=\"margin-top:8px;font-size:.78rem;color:var(--txt-s)\">\n        \ud83d\udcce \u5f15\u7528\uff1a\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b\u00a7\u4e8c \u65b9\u6848\u8bbe\u8ba1<br>\n        \ud83d\udcce \u5f15\u7528\uff1a\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b\u65e5\u7acb\u6c1f\u7cfb\u7edf\u8bbe\u8ba1\u89c4\u8303\n      <\/p>\n    <\/div>\n  <\/details>\n\n  <details>\n    <summary>\ud83d\udcb0 \u8bc1\u636e\u94fe 2\/3 \u00b7 \u4ef7\u683c\u53e3\u5f84\u4f9d\u636e\uff08\u4f9d\u636e\u300a\u4ea7\u54c1\u4ef7\u683c\u5e93V5.0\u300b\uff09<\/summary>\n    <div class=\"inner\">\n      <p><b>\u4ef7\u683c\u53e3\u5f84\u6765\u6e90\u58f0\u660e\uff1a<\/b><\/p>\n      <p>\u2460 \u8212\u4eab\u7cfb\u5217 \u2014\u2014 \u6309\u5382\u5546\u6307\u5bfc\u4ef7 <b>8 \u6298<\/b>\u6267\u884c\uff08\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93 V5.0\uff09<\/p>\n      <p>\u2461 \u5c0a\u777f\u5168\u6548\u7cfb\u5217 \u2014\u2014 \u6309\u5382\u5546\u6307\u5bfc\u4ef7 <b>8.5 \u6298<\/b>\u6267\u884c\uff08\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93 V5.0\uff09<\/p>\n      <p>\u2462 \u6c34\u6a21\u5757 RWMG-280FWNZ1Q \u2014\u2014 \u4e0d\u6253\u6298\uff08\u7ec8\u7aef\u4ef7\uff09<\/p>\n      <p>\u2463 \u536b\u6d74\u7a7a\u8c03 RCIS-25FSWNQD \u2014\u2014 \u4e0d\u6253\u6298\uff08\u7ec8\u7aef\u4ef7\uff09<\/p>\n      <p>\u2464 \u4e91\u51c0\u65b0\u98ce KPI-3521Q3A\/F \u2014\u2014 \u5382\u5546\u6307\u5bfc\u4ef7 6,200 + \u5b89\u88c5\u8d39 6,000<\/p>\n      <p>\u2465 \u5730\u6696\u7cfb\u7edf \u2014\u2014 179\u5143\/\u33a1 \u542b\u4f1f\u661fF-PPRCT\u4e3b\u7ba1+De20\u76d8\u7ba1\uff08\u4f1f\u661f\u963b\u6c27\u7ba1\uff09+\u66fc\u745e\u5fb7\u8054\u52a8+\u4fdd\u6e29\u56de\u586b\uff08\u542b 50 \u5e74\u8054\u4fdd\uff09<\/p>\n      <p style=\"margin-top:8px\">\n        <b>\u603b\u4ef7\u6838\u7b97\uff1a<\/b>\n      <\/p>\n      <p style=\"margin-left:16px\">\n        \u8212\u4eab\u7cfb\u7edf\u4e00\uff1a9,330\uff08\u5916\u673a\uff09+ 4,100\uff0836\u5185\u673a\uff09+ 4,410\uff0871\u5185\u673a\uff09+ 4,010 + 4,010\uff0822\u5185\u673a\u00d72\uff09+ 12,200\uff08\u4e91\u51c0\u65b0\u98ce\uff09= <b>\u00a538,060<\/b>\uff08\u4e0d\u542b\u9664\u6e7f\u5305\uff09<br>\n        \u5c0a\u777f\u4e3b\u673a\uff1a30,170\uff08\u4e3b\u673a\u542b\u5b89\u88c5\uff09+ 13,325\uff08\u6c34\u6a21\u5757\u542b\u5b89\u88c5\uff09= <b>\u00a543,495<\/b><br>\n        \u5c0a\u777f\u5ba4\u5185\u673a\uff1a5,680+5,925+6,052+6,352+6,352+6,193+6,714+8,688 = <b>\u00a551,956<\/b><br>\n        \u5730\u6696\u7cfb\u7edf\uff1a250\u33a1 \u00d7 179\u5143\/\u33a1 = <b>\u00a544,750<\/b><br>\n        <b>\u8bbe\u5907\u5408\u8ba1\uff1a\u00a538,060 + \u00a543,495 + \u00a551,956 + \u00a544,750 = \u00a5178,261<\/b>\n      <\/p>\n      <p style=\"margin-top:8px;font-size:.78rem;color:var(--txt-s)\">\n        \ud83d\udcce \u5f15\u7528\uff1a\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b\u00a7\u56db \u900f\u660e\u62a5\u4ef7<br>\n        \u23f0 <b>\u62a5\u4ef7\u6709\u6548\u671f\uff1a30\u5929<\/b>\uff08\u81ea 2026-07-26 \u8d77\u7b97 \u00b7 2026-08-25 \u5230\u671f\uff09\n      <\/p>\n    <\/div>\n  <\/details>\n\n  <details>\n    <summary>\ud83d\udee1 \u8bc1\u636e\u94fe 3\/3 \u00b7 \u8d28\u4fdd\u4f9d\u636e\uff08\u4f9d\u636e\u5382\u5bb6\u8d28\u4fdd\u6761\u6b3e + \u9f99\u8109\u552e\u540e\u627f\u8bfa\uff09<\/summary>\n    <div class=\"inner\">\n      <p><b>\u8d28\u4fdd\u671f\u5bf9\u7167\u8868\uff1a<\/b><\/p>\n      <p>\u2460 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6574\u673a\uff08\u5c0a\u777f+\u8212\u4eab\uff09 \u2014\u2014 \u5382\u5bb6\u8d28\u4fdd <b>60 \u4e2a\u6708<\/b>\uff085 \u5e74\uff09\uff0c\u65e5\u7acb\u4e2d\u56fd\u5b98\u7f51\u516c\u5e03\u6807\u51c6<\/p>\n      <p>\u2461 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u538b\u7f29\u673a \u2014\u2014 \u5382\u5bb6\u8d28\u4fdd <b>60 \u4e2a\u6708<\/b>\uff08\u6838\u5fc3\u90e8\u4ef6\u540c\u7b49\u6574\u673a\uff09<\/p>\n      <p>\u2462 \u4f1f\u661f\u5730\u6696\u7ba1\u9053\uff08\u963b\u6c27\u7ba1\uff09 \u2014\u2014 \u4e09\u65b9\u8054\u4fdd <b>50 \u5e74<\/b>\uff08\u4f1f\u661f\u5382\u5bb6 + \u9f99\u8109\u5b89\u88c5 + \u4fdd\u9669\uff09<\/p>\n      <p>\u2463 \u9f99\u8109\u5b89\u88c5\u5de5\u7a0b \u2014\u2014 \u9f99\u8109\u627f\u8bfa <b>2 \u5e74\u514d\u8d39\u4e0a\u95e8 + \u9690\u853d\u5de5\u7a0b\u7ec8\u8eab\u8d1f\u8d23<\/b><\/p>\n      <p>\u2464 \u4f4e\u6e29\u9664\u6e7f\u5305\uff08\u9009\u914d\uff09 \u2014\u2014 \u5382\u5bb6\u8d28\u4fdd <b>60 \u4e2a\u6708<\/b>\uff08\u4e0e\u65e5\u7acb\u6574\u673a\u540c\uff09<\/p>\n      <p>\u2465 \u4e91\u51c0\u65b0\u98ce KPI-3521Q3A\/F \u2014\u2014 \u5382\u5bb6\u8d28\u4fdd <b>60 \u4e2a\u6708<\/b>\uff085 \u5e74\uff09<\/p>\n      <p style=\"margin-top:8px;font-size:.78rem;color:var(--txt-s)\">\n        \ud83d\udcce \u5f15\u7528\uff1a\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b\u00a7\u4e03 \u670d\u52a1\u4fdd\u969c<br>\n        \ud83d\udcce \u5f15\u7528\uff1a\u7b2c\u516d\u7ae0 6.1 \u8d28\u4fdd\u660e\u7ec6 \u00b7 \u672c\u6863\u6848\u4e66<br>\n        \ud83d\udcce \u5f15\u7528\uff1a\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b\u552e\u540e\u7ef4\u4fdd\u6807\u51c6\n      <\/p>\n    <\/div>\n  <\/details>\n<\/section>\n\n<!-- ============ \u5b89\u88c5\u8f85\u6750\u6e05\u5355 \u00b7 V1.3 \u5f3a\u5236\u9879 #9 ============ -->\n<section class=\"sec\">\n  <h2>\ud83d\udd27 \u5b89\u88c5\u8f85\u6750\u6e05\u5355\uff08V1.3 \u5f3a\u5236\u9879 #9 \u00b7 \u6307\u4ee46 \u9644\u8868A+\u9644\u8868G\uff09<\/h2>\n  <p style=\"font-size:.84rem;color:var(--txt-s);margin-bottom:10px\">\n    \u4f9d\u636e\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b\u6307\u4ee46 \u9644\u8868A\uff08\u7eaf\u6c1f\u7cfb\u7edf\u8f85\u6750\uff09+ \u9644\u8868G\uff08\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u8f85\u6750\uff09\n  <\/p>\n\n  <h4>\ud83e\uddca \u9644\u8868A \u00b7 \u4e2d\u592e\u7a7a\u8c03\u7eaf\u6c1f\u7cfb\u7edf\u8f85\u6750\uff08\u8212\u4eab+\u5c0a\u777f\uff09<\/h4>\n  <table>\n    <tr><th style=\"width:8%\">\u5e8f\u53f7<\/th><th style=\"width:24%\">\u8f85\u6750\u540d\u79f0<\/th><th style=\"width:14%\">\u89c4\u683c<\/th><th style=\"width:14%\">\u6570\u91cf<\/th><th style=\"width:20%\">\u7528\u9014<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <tr><td>1<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>\u03a69.52 \/ \u03a615.88 \/ \u03a622.2<\/td><td>\u6309\u7c73\u6570<\/td><td>\u51b7\u5a92\u8f93\u914d\u7ba1\uff08\u8212\u4eab+\u5c0a\u777f\u53cc\u7cfb\u7edf\uff09<\/td><td>\u56fd\u6807 TP2 \u8131\u8102\u7d2b\u94dc\u7ba1<\/td><\/tr>\n    <tr><td>2<\/td><td>\u51b7\u5a92\uff08R410A\uff09<\/td><td>\u2014<\/td><td>\u6309\u7cfb\u7edf<\/td><td>\u5236\u51b7\u5242\uff08\u8212\u4eab+\u5c0a\u777f\uff09<\/td><td>\u65e5\u7acb\u539f\u5382\u51b7\u5a92<\/td><\/tr>\n    <tr><td>3<\/td><td>PVC-U \u51b7\u51dd\u6c34\u7ba1<\/td><td>De32<\/td><td>\u6309\u7c73\u6570<\/td><td>\u5185\u673a\u6392\u6c34\uff0812\u53f0\u5185\u673a\uff09<\/td><td>\u56fd\u6807\u7ed9\u6c34\u7ea7<\/td><\/tr>\n    <tr><td>4<\/td><td>\u4f18\u83f2\u7279\u4fdd\u6e29\u68c9<\/td><td>19mm \u539a<\/td><td>\u6309\u7c73\u6570<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\uff08\u53cc\u7cfb\u7edf\uff09<\/td><td>B1 \u7ea7\u963b\u71c3<\/td><\/tr>\n    <tr><td>5<\/td><td>\u5854\u724c\u7535\u7ebf<\/td><td>2.5 \/ 4 \/ 6 mm\u00b2<\/td><td>\u6309\u7c73\u6570<\/td><td>\u5f3a\u5f31\u7535\u5206\u8272\uff08\u53cc\u7cfb\u7edf\uff09<\/td><td>\u56fd\u6807\u963b\u71c3<\/td><\/tr>\n    <tr><td>6<\/td><td>\u4fe1\u53f7\u7ebf + \u7535\u6e90\u7ebf<\/td><td>RVV 4\u00d70.75<\/td><td>\u6309\u7c73\u6570<\/td><td>\u5185\u5916\u673a\u901a\u8baf\uff08\u53cc\u7cfb\u7edf\uff09<\/td><td>\u5c4f\u853d\u7ebf<\/td><\/tr>\n    <tr><td>7<\/td><td>\u5206\u6b67\u7ba1 + \u5f2f\u5934 + \u63a5\u5934<\/td><td>\u2014<\/td><td>\u6309\u7cfb\u7edf<\/td><td>\u7ba1\u8def\u5206\u652f\uff08\u5c0a\u777f8\u53f0\u5185\u673a\uff09<\/td><td>\u65e5\u7acb\u539f\u5382\u914d\u4ef6<\/td><\/tr>\n    <tr><td>8<\/td><td>\u51cf\u632f\u57ab + \u540a\u7801<\/td><td>\u2014<\/td><td>\u6309\u7cfb\u7edf<\/td><td>\u51cf\u632f\u964d\u566a\uff08\u53cc\u5916\u673a\uff09<\/td><td>\u6807\u51c6\u5316\u8f85\u6750<\/td><\/tr>\n  <\/table>\n\n  <h4>\ud83d\udd25 \u9644\u8868G \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u7cfb\u7edf\u8f85\u6750\uff08\u672c\u6848\u4e3b\u8981\uff09<\/h4>\n  <table>\n    <tr><th style=\"width:8%\">\u5e8f\u53f7<\/th><th style=\"width:24%\">\u8f85\u6750\u540d\u79f0<\/th><th style=\"width:14%\">\u89c4\u683c<\/th><th style=\"width:14%\">\u6570\u91cf<\/th><th style=\"width:20%\">\u7528\u9014<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <tr><td>1<\/td><td>\u4f1f\u661f F-PPRCT \u4e3b\u7ba1<\/td><td>De32<\/td><td>\u6309\u7c73\u6570<\/td><td>\u5730\u6696\u4e3b\u7ba1\u8f93\u914d<\/td><td>F-PPRCT \u5347\u7ea7\u6b3e<\/td><\/tr>\n    <tr><td>2<\/td><td>\u4f1f\u661f PE-RT \u963b\u6c27\u5730\u6696\u7ba1<\/td><td>De20\u00d72.0<\/td><td>250\u33a1<\/td><td>\u5730\u76d8\u7ba1\u76d8\u7ed5<\/td><td>50 \u5e74\u4e09\u65b9\u8054\u4fdd \u00b7 \u963b\u6c27<\/td><\/tr>\n    <tr><td>3<\/td><td>\u955c\u9762\u53cd\u5c04\u819c<\/td><td>0.05mm<\/td><td>250\u33a1<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>4<\/td><td>\u767d\u6676\u677f\uff08\u6324\u5851\u805a\u82ef\u677f\uff09<\/td><td>2cm \u539a B1 \u7ea7<\/td><td>250\u33a1<\/td><td>\u5e95\u90e8\u4fdd\u6e29<\/td><td>\u9ad8\u5bc6\u5ea6\u767d\u6676\u677f<\/td><\/tr>\n    <tr><td>5<\/td><td>\u65e5\u7acb\u6c34\u6e29\u63a7\u5236\u5668<\/td><td>\u914d\u5c0a\u777f\u5168\u6548<\/td><td>1 \u5957<\/td><td>\u6c34\u6a21\u5757\u6c34\u6e29\u63a7\u5236<\/td><td>\u539f\u5382\u914d\u5957<\/td><\/tr>\n    <tr><td>6<\/td><td>\u66fc\u745e\u5fb7\u7535\u70ed\u6267\u884c\u5668<\/td><td>230V \u5e38\u5f00\u578b<\/td><td>\u6309\u56de\u8def<\/td><td>\u7535\u70ed\u9a71\u52a8\uff08\u5206\u96c6\u6c34\u5668\uff09<\/td><td>\u914d\u66fc\u745e\u5fb7\u8054\u52a8<\/td><\/tr>\n    <tr><td>7<\/td><td>\u5b89\u5168\u9600<\/td><td>\u914d\u6c34\u6a21\u5757<\/td><td>1 \u5957<\/td><td>\u6c34\u6a21\u5757\u8d85\u538b\u4fdd\u62a4<\/td><td>\u539f\u5382\u914d\u5957<\/td><\/tr>\n    <tr><td>8<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u914d\u6c34\u6a21\u5757<\/td><td>1 \u5957<\/td><td>\u6c34\u529b\u5e73\u8861<\/td><td>\u539f\u5382\u914d\u5957<\/td><\/tr>\n    <tr><td>9<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>\u914d\u6c34\u6a21\u5757<\/td><td>1 \u5957<\/td><td>\u7cfb\u7edf\u6392\u6c14<\/td><td>\u539f\u5382\u914d\u5957<\/td><\/tr>\n    <tr><td>10<\/td><td>Y \u578b\u8fc7\u6ee4\u5668<\/td><td>\u914d\u6c34\u6a21\u5757<\/td><td>1 \u5957<\/td><td>\u6c34\u7cfb\u7edf\u8fc7\u6ee4<\/td><td>\u539f\u5382\u914d\u5957<\/td><\/tr>\n    <tr><td>11<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>6-8 \u8def<\/td><td>1 \u5957<\/td><td>\u6c34\u529b\u5206\u914d\uff08\u542b\u6d41\u91cf\u8c03\u8282\u9600\uff09<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>12<\/td><td>\u8fb9\u754c\u4fdd\u6e29\u6761<\/td><td>8mm \u00d7 100mm<\/td><td>\u6309\u5468\u957f<\/td><td>\u4f38\u7f29\u7f1d<\/td><td>PE \u6750\u8d28<\/td><\/tr>\n    <tr><td>13<\/td><td>\u94a2\u4e1d\u7f51 + \u5361\u9489<\/td><td>\u2014<\/td><td>\u6309\u9762\u79ef<\/td><td>\u7ba1\u8def\u56fa\u5b9a<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>14<\/td><td>\u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b<\/td><td>C15<\/td><td>5-6cm \u539a<\/td><td>\u84c4\u70ed\u5c42\uff08\u542b\u65bd\u5de5\uff09<\/td><td>\u2014<\/td><\/tr>\n  <\/table>\n\n  <h4>\ud83c\udf2c \u9644\u8868H \u00b7 \u65b0\u98ce\u7cfb\u7edf\u8f85\u6750\uff08\u4e91\u51c0350\uff09<\/h4>\n  <table>\n    <tr><th>\u8f85\u6750<\/th><th>\u89c4\u683c<\/th><th>\u7528\u9014<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <tr><td>PVC \u98ce\u7ba1 + \u98ce\u53e3 + \u51cf\u632f\u540a\u4ef6<\/td><td>De75\/110<\/td><td>\u65b0\u98ce\u7ba1\u9053\u8f93\u914d<\/td><td>\u9632\u7ed3\u9732\u5904\u7406<\/td><\/tr>\n    <tr><td>\u5168\u70ed\u4ea4\u6362\u82af<\/td><td>KPI-3521Q3A\/F \u6807\u914d<\/td><td>\u53cc\u5411\u6d41\u70ed\u56de\u6536<\/td><td>\u539f\u5382\u914d\u7f6e<\/td><\/tr>\n    <tr><td>PM2.5 \u6ee4\u7f51<\/td><td>\u539f\u5382\u914d\u5957<\/td><td>PM2.5 \u51c0\u5316\u7387\u226598%<\/td><td>\u5b9a\u671f\u66f4\u6362<\/td><\/tr>\n  <\/table>\n<\/section>\n\n<!-- ============ \u6570\u636e\u6e90\u6807\u6ce8 \u00b7 V1.3 \u5f3a\u5236\u9879 #6 ============ -->\n<section class=\"sec\">\n  <div class=\"data-source\">\n    <strong>\ud83d\udcda \u6570\u636e\u6e90\u6807\u6ce8\uff08V1.3 \u5f3a\u5236\u9879 #6 \u00b7 \u5e38\u9a7b\u9875\u811a\u5f0f\u58f0\u660e\uff09<\/strong><br>\n    \u672c\u6863\u6848\u4e66\u6570\u636e\u6765\u6e90\uff1a<br>\n    \u2460 <b>\u300a\u987e\u5ba2\u4fe1\u606f\u5361_\u718a\u8001\u5e08.md\u300b<\/b>\uff08\u5efa\u6863\u65e5\u671f 2026-07-26\uff0c\u9500\u552e \u4f59\u6653\u73b2\uff09<br>\n    \u2461 <b>\u300a\u987e\u5ba2\u4fe1\u606f\u5361_\u718a\u8001\u5e08_\u53c2\u7167\u5218\u8001\u5e08\u683c\u5f0f.md\u300b<\/b>\uff08V1.0 \u4fe1\u606f\u5361 \u00b7 \u5b8c\u6574\u7248\uff09<br>\n    \u2462 <b>\u300a\u987e\u5ba2\u4fe1\u606f\u5361_\u718a\u8001\u5e08_JSON\u66f4\u65b0.md\u300b<\/b>\uff08V1.1 JSON \u683c\u5f0f\uff09<br>\n    \u2463 <b>\u300a\u65b9\u6848_\u718a\u8001\u5e08\u522b\u5885_\u5168\u5c4b\u6696\u901a\u7cfb\u7edf\u65b9\u6848\u4e66.md\u300b<\/b>\uff08\u65b9\u6848\u7a3f\uff0c\u65b9\u6848\u53f7 KH-2026-0383-FA01\uff09<br>\n    \u2464 <b>\u65b9\u6848URL\uff1a<\/b>https:\/\/longmai-nt.com\/?page_id=7224\uff082026-07-29 \u53d1\u5e03\uff09<br>\n    \u2465 <b>\u6307\u4ee402 \u00b7 \u4ea7\u54c1\u4ef7\u683c\u5e93 V5.0<\/b>\uff08\u6240\u6709\u8bbe\u5907\u6298\u540e\u4ef7\/\u5b89\u88c5\u8d39\u6765\u6e90\uff0c<b>\u4ef7\u683c\u5feb\u7167 snap-2026.08.07-XX<\/b>\uff09<br>\n    \u2466 <b>\u300a\u5ba2\u6237\u6863\u6848\u4e66\u6a21\u677fv1.3\u300b<\/b>\uff082026-08-05 \u00b7 \u672c\u6863\u6848\u4e66\u7ed3\u6784\u4e0e\u5b57\u6bb5\u9075\u5faa\u8be5\u6a21\u677f\uff09<br>\n    \u2467 <b>\u300a\u65b9\u6848\u6a21\u677f\u6846\u67b6V1.5\u300b<\/b>\uff08\u8bbe\u5907\u914d\u7f6e+\u62a5\u4ef7\u6c47\u603b\u5b57\u6bb5\u7ed3\u6784\uff09<br>\n    \u2468 <b>\u300a\u7ba1\u7ebf\u8bbe\u8ba1\u5951\u7ea6v3.3\u300b<\/b>\uff08\u8fde\u63a5\u7387\u6821\u6838+\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6+\u8f85\u6750\u6e05\u5355\u9644\u8868A\/G\uff09<br>\n    \u2469 <b>\u300aGEO\u5baa\u6cd5V6.2\u300b<\/b>\uff08\u65b9\u6848URL + GEO\u6848\u4f8bURL \u53cc\u94fe\u89c4\u8303\uff09<br>\n    <br>\n    <span style=\"color:var(--gold);font-weight:600\">\u203b \u6587\u6863\u751f\u6210\u65f6\u95f4\uff1a<\/span>2026-08-07 \uff5c <span style=\"color:var(--gold);font-weight:600\">\u6863\u6848\u4e66\u7248\u672c\uff1a<\/span>V1.3 \uff5c <span style=\"color:var(--gold);font-weight:600\">\u751f\u6210\u65b9\u5f0f\uff1a<\/span>\u9f99\u8109 AI \u52a9\u624b \u00b7 \u4f59\u6653\u73b2\u590d\u6838 \uff5c <span style=\"color:var(--gold);font-weight:600\">\u5143\u6570\u636e\uff1a<\/span>v0.3.2\n  <\/div>\n<\/section>\n\n<!-- ============ \u9875\u811a \u00b7 \u53cc\u95e8\u5e97 \u00b7 V1.3 \u5f3a\u5236\u9879 #10 ============ -->\n<footer class=\"footer\">\n  <div class=\"brand\">\ud83c\udfdb \u9f99\u8109\u6696\u901a \u00b7 22 \u5e74\u7cbe\u5de5 \u00b7 \u5ba2\u6237\u6210\u529f\u6863\u6848<\/div>\n  <div class=\"stores\">\n    <div class=\"store\">\n      <h4>\ud83d\udccd \u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff08\u5ba2\u6237\u6210\u529f\u603b\u90e8\uff09<\/h4>\n      <div class=\"info\"><b>\u7535\u8bdd\uff1a<\/b><a href=\"tel:028-86131795\">028-86131795<\/a><\/div>\n      <div class=\"info\"><b>\u5730\u5740\uff1a<\/b>\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/div>\n      <div class=\"info\"><b>\u670d\u52a1\uff1a<\/b>\u6696\u901a\u5168\u7cfb\u7edf \u00b7 \u5ba2\u6237\u6863\u6848\u4e3b\u5e93<\/div>\n      <div class=\"info\"><b>\u8425\u4e1a\uff1a<\/b>09:30 \u2014 18:00\uff08\u6bcf\u65e5\uff09<\/div>\n    <\/div>\n    <div class=\"store\">\n      <h4>\ud83d\udccd \u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/h4>\n      <div class=\"info\"><b>\u7535\u8bdd\uff1a<\/b><a href=\"tel:028-65272586\">028-65272586<\/a><\/div>\n      <div class=\"info\"><b>\u5730\u5740\uff1a<\/b>\u6210\u90fd\u65b0\u90fd\u533a\u5317\u5bcc\u68ee\u5bb6\u5c45\u5efa\u6750\u57ce<\/div>\n      <div class=\"info\"><b>\u670d\u52a1\uff1a<\/b>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u65b0\u98ce \u00b7 \u51c0\u6c34 \u4f53\u9a8c\u4e2d\u5fc3<\/div>\n      <div class=\"info\"><b>\u8425\u4e1a\uff1a<\/b>09:30 \u2014 18:00\uff08\u6bcf\u65e5\uff09<\/div>\n    <\/div>\n  <\/div>\n  <div class=\"sales-line\">\n    \ud83e\uddd1\u200d\ud83d\udcbc <b>\u60a8\u7684\u9500\u552e\u987e\u95ee\uff1a\u4f59\u6653\u73b2<\/b> \uff5c\n    \ud83d\udcde <a href=\"tel:13008113409\"><b>13008113409<\/b><\/a>\uff08\u5fae\u4fe1\u540c\u53f7\uff09 \uff5c\n    \ud83d\udce7 yao.xueling@longmai-nt.com<br>\n    <span style=\"font-size:.74rem;color:var(--txt-s)\">\u4ece\u4e1a22\u5e74 \u00b7 \u670d\u52a1\u8d85\u8fc7 1,800+ \u6237\u6210\u90fd\u5bb6\u5ead\u6696\u901a\u7cfb\u7edf \u00b7 \u60a8\u7684\u5168\u5468\u671f\u8d23\u4efb\u4eba<\/span>\n  <\/div>\n  <p style=\"text-align:center;margin-top:16px;font-size:.74rem;color:var(--txt-s)\">\n    \u00a9 2024-2026 \u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6210\u529f\u6863\u6848\u7cfb\u7edf \u00b7\n    \u4f9d\u636e\u300a\u5ba2\u6237\u6863\u6848\u4e66\u6a21\u677fv1.3\u300b\u751f\u6210 \u00b7\n    <a href=\"https:\/\/longmai-nt.com\" target=\"_blank\">longmai-nt.com<\/a>\n  <\/p>\n<\/footer>\n\n<\/div><!-- \/.wrap -->\n\n","protected":false},"excerpt":{"rendered":"<p>LONGMAI \u00b7 CUSTOMER S [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-9104","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=9104\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"LONGMAI \u00b7 CUSTOMER S [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=9104\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-07T15:30:26+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9104\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9104\",\"name\":\"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-07-30T04:06:45+00:00\",\"dateModified\":\"2026-08-07T15:30:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9104#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9104\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9104#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=9104","og_locale":"zh_CN","og_type":"article","og_title":"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"LONGMAI \u00b7 CUSTOMER S [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=9104","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-08-07T15:30:26+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"10 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=9104","url":"https:\/\/longmai-nt.com\/?page_id=9104","name":"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-07-30T04:06:45+00:00","dateModified":"2026-08-07T15:30:26+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=9104#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=9104"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=9104#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u718a\u8001\u5e08\u522b\u5885 \u00b7 250\u33a1 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ba2\u6237\u6863\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9104","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=9104"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9104\/revisions"}],"predecessor-version":[{"id":10027,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9104\/revisions\/10027"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=9104"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}