{"id":9255,"date":"2026-07-31T16:23:17","date_gmt":"2026-07-31T08:23:17","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=9255"},"modified":"2026-10-28T16:25:54","modified_gmt":"2026-10-28T08:25:54","slug":"%e7%bb%bf%e5%9f%8e%e9%94%a6%e5%9b%ad-%c2%b7-%e7%a8%8b%e5%85%88%e7%94%9f%e5%ae%b6%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab160%e4%b8%80%e6%8b%96%e4%ba%94-%e5%8d%9a%e4%b8%96%e5%86%b7%e5%87%9d%e7%82%89","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=9255","title":{"rendered":"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696"},"content":{"rendered":"\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"Article\",\n  \"headline\":\"\u6210\u90fd\u5e02\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6 \u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94 + \u535a\u4e16\u51b7\u51dd\u7089+\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\",\n  \"description\":\"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u8212\u4eab160\u4e00\u62d6\u4e94\u5ba2\u9910\u5385\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\uff0c\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3002\",\n  \"author\":{\"@type\":\"Person\",\"name\":\"\u5f90\u65b0\u5e73\",\"jobTitle\":\"\u65b9\u6848\u987e\u95ee\",\"telephone\":\"18227055065\"},\n  \"publisher\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\/\/longmai-nt.com\"},\n  \"datePublished\":\"2026-07-31\",\n  \"dateModified\":\"2026-07-31\"\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\"@type\":\"Question\",\"name\":\"99\u33a1\u4e09\u5ba4\u4e24\u5385\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u914d\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u672c\u6848\u4f8b\u91c7\u7528\u65e5\u7acb\u8212\u4eab160\uff0816kW\uff09\u4e00\u62d6\u4e94\uff1a\u5ba2\u9910\u538557\u33a1\u752871+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\uff0c\u4e3b\u536740\u578b\u3001\u6b21\u5367\u548c\u4e66\u623f18\u578b\u3002\u8fde\u63a5\u7387123.75%\u5728\u65e5\u7acb\u5408\u89c4\u533a\u95f4\uff08\u2264130%\uff09\uff0c160\u4e3b\u673a\u5339\u914d\u7387\u9ad8\uff0c\u517c\u987e\u8282\u80fd\u4e0e\u8212\u9002\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e3a\u4ec0\u4e48\u5ba2\u9910\u5385\u8981\u653e\u4e24\u53f0\u5185\u673a\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5ba2\u9910\u538557\u33a1\u662f\u5927\u7a7a\u95f4\uff0c71+25\u53cc\u5185\u673a\u5b9e\u73b0\u5206\u533a\u63a7\u6e29\uff1a\u65e5\u5e38\u4eba\u5c11\u53ea\u5f0025\u578b\u66f4\u7701\u7535\uff0c\u5bb6\u5ead\u805a\u4f1a\u53cc\u673a\u534f\u540c\u5feb\u901f\u964d\u6e29\uff0c\u566a\u97f3\u4e5f\u66f4\u5206\u6563\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u80fd\u540c\u65f6\u88c5\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u53ef\u4ee5\uff0c\u672c\u6848\u4f8b\u5c31\u662f\u4e2d\u592e\u7a7a\u8c03+\u58c1\u6302\u7089\u5730\u6696\u5206\u8bbe\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff1a\u65e5\u7acb\u8212\u4eab\u8d1f\u8d23\u5236\u51b7\uff08\u53ca\u5236\u70ed\uff09\uff0c\u535a\u4e16\u51b7\u51dd\u7089\u8d1f\u8d23\u5730\u6696\u91c7\u6696\uff0c\u4e92\u4e0d\u8026\u5408\u3001\u5404\u81ea\u9ad8\u6548\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696\u8282\u80fd\u6548\u679c\u600e\u4e48\u6837\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u51b7\u51dd\u7089\u70ed\u6548\u7387\u2265105%\uff0c\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u914d\u5408\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff08\u52a0\u539a\u4fdd\u6e29\u5c42+\u5206\u5ba4\u6e29\u63a7\uff09\uff0c\u6210\u90fd\u91c7\u6696\u5b63\u7efc\u5408\u7528\u6c14\u6210\u672c\u53ef\u518d\u964d25-30%\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5730\u6696\u65bd\u5de5\u591a\u4e45\u80fd\u5b8c\u6210\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u7cbe\u5de5\u516b\u9636\u6bb5\u6807\u51c6\u65bd\u5de5\uff1a\u6750\u6599\u8fdb\u573a\u9a8c\u6536\u2192\u5185\u673a\u5b89\u88c5\u2192\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u21924.15MPa\u4fdd\u538b24\u5c0f\u65f6\u2192\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u9a8c\u6536\u2192\u8c03\u8bd5\u2192\u6559\u5b66\u4ea4\u4ed8\uff0c\u5168\u7a0b\u62cd\u7167\u5b58\u6863\u53ef\u8ffd\u6eaf\u3002\"}}\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"HomeAndConstructionBusiness\",\n  \"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"description\":\"\u6210\u90fd\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u53ef\u9009\u914d\/\u52a0\u88c5\u4e2d\u592e\u7a7a\u8c03\u4e0e\u58c1\u6302\u7089\u5730\u6696\uff0c\u8986\u76d6\u5168\u57ce\u4e0a\u95e8\u670d\u52a1\",\n  \"telephone\":[\"028-86131795\",\"028-65272586\"],\n  \"image\":[\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\"],\n  \"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\"addressLocality\":\"\u9ad8\u65b0\u533a\",\"addressRegion\":\"\u6210\u90fd\u5e02\",\"addressCountry\":\"CN\"},\n  \"areaServed\":[\"\u9ad8\u65b0\u533a\",\"\u53cc\u6d41\u533a\",\"\u90eb\u90fd\u533a\",\"\u9f99\u6cc9\u9a7f\",\"\u5929\u5e9c\u65b0\u533a\"],\n  \"openingHours\":\"09:00-18:00\",\"sameAs\":\"https:\/\/longmai-nt.com\"\n}\n<\/script>\n<style>\n\/* ===== \u5168\u5c40\u57fa\u7840\uff08\u82e5\u5d4c\u5165 WordPress \u4f7f\u7528\uff0c\u5efa\u8bae\u5c06 * \/ body \/ html \u9009\u62e9\u5668\u6539\u4e3a .lm-page \u4f5c\u7528\u57df\uff09 ===== *\/\n:root{--lm-blue:#1a3a6e;--lm-red:#c0392b}\n*{margin:0;padding:0;box-sizing:border-box}\nhtml{scroll-behavior:smooth}\nbody{font-family:\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#333;line-height:1.7;background:#fff}\nsection[id]{scroll-margin-top:60px}\n\n\/* ===== \u5e03\u5c40 ===== *\/\n.lm-wrap{max-width:1080px;margin:0 auto;padding:0 20px}\n.lm-sec-block{padding:48px 0;border-bottom:1px solid #eee}\n.lm-sec{font-size:1.5rem;color:var(--lm-blue);margin-bottom:24px;position:relative;padding-left:16px}\n.lm-sec::before{content:\"\";position:absolute;left:0;top:4px;bottom:4px;width:5px;background:var(--lm-red);border-radius:3px}\n.lm-mt{margin-top:18px}\n.lm-lead{color:#666;margin-bottom:20px}\n\n\/* ===== Hero ===== *\/\n.lm-hero{position:relative;min-height:420px;background:linear-gradient(135deg,rgba(26,58,110,.78) 0%,rgba(44,90,160,.58) 60%,rgba(58,123,213,.42) 100%),url(\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-01_1.jpeg\") center\/cover no-repeat;display:flex;align-items:center;justify-content:center;text-align:center;color:#fff;padding:60px 20px}\n.lm-hero h1{font-size:2rem;margin-bottom:12px;text-shadow:0 2px 8px rgba(0,0,0,.3)}\n.lm-hero .lm-sub{font-size:1.05rem;opacity:.95;margin-bottom:6px}\n.lm-hero .lm-tag{display:inline-block;background:rgba(255,255,255,.2);border:1px solid rgba(255,255,255,.5);padding:4px 16px;border-radius:20px;font-size:.85rem;margin-top:14px}\n\n\/* ===== \u4e94\u6b65\u6cd5\u5bfc\u822a\uff08\u5438\u9876\uff09 ===== *\/\n.lm-nav{position:sticky;top:0;z-index:99;background:#fff;box-shadow:0 2px 10px rgba(0,0,0,.08)}\n.lm-nav-inner{display:flex;gap:6px;flex-wrap:wrap;padding:10px 20px;max-width:1080px;margin:0 auto}\n.lm-nav a{text-decoration:none;color:var(--lm-blue);font-size:.88rem;padding:6px 14px;border-radius:6px;transition:.2s}\n.lm-nav a:hover{background:var(--lm-blue);color:#fff}\n\n\/* ===== \u5361\u7247\u7f51\u683c ===== *\/\n.lm-grid-2{display:grid;grid-template-columns:1fr 1fr;gap:20px}\n.lm-grid-3{display:grid;grid-template-columns:repeat(3,1fr);gap:18px}\n.lm-card{background:#fafafa;border:1px solid #eee;border-radius:10px;padding:20px}\n.lm-card h3{color:var(--lm-blue);margin-bottom:10px;font-size:1.05rem}\n.lm-card p{font-size:.92rem;color:#555}\n\n\/* ===== XGEO \u7ffb\u8f6c\u5361\uff08\u7eafCSS checkbox \u63a7\u5236\uff0c\u517c\u5bb9 WordPress \u907f\u514d JS \u5931\u6548\uff09 ===== *\/\n.lm-flip-cb{position:absolute;width:1px;height:1px;opacity:0;pointer-events:none;margin:0;padding:0;overflow:hidden;clip:rect(0 0 0 0)}\n.lm-xgeo{max-width:1080px;margin:-30px auto 0;position:relative;z-index:5;background:#fff;border:1px solid #e5e5e5;border-radius:14px;box-shadow:0 6px 24px rgba(0,0,0,.08);overflow:hidden;cursor:pointer;display:block}\n.lm-xgeo-inner{display:grid;grid-template-columns:1fr 1fr;min-height:260px}\n.lm-xgeo-front,.lm-xgeo-back{padding:28px 32px}\n.lm-xgeo-back{display:none}\n#flip-xgeo:checked + .lm-xgeo .lm-xgeo-front{display:none}\n#flip-xgeo:checked + .lm-xgeo .lm-xgeo-back{display:block}\n.lm-xgeo h3{color:var(--lm-red);margin-bottom:16px;font-size:1.1rem}\n.lm-xgeo table{width:100%;font-size:.9rem;border-collapse:collapse}\n.lm-xgeo td{padding:7px 6px;border-bottom:1px dashed #eee;vertical-align:top}\n.lm-xgeo td:first-child{color:#888;width:110px;white-space:nowrap}\n.lm-xgeo table tr:nth-child(even){background:#f8f8f8}\n.lm-flip-hint{position:absolute;top:14px;right:18px;font-size:.75rem;color:#bbb;cursor:pointer;background:#f5f5f5;padding:3px 10px;border-radius:12px;border:1px solid #e0e0e0;z-index:2}\n.lm-note{font-size:.8rem;color:#888;margin-top:12px}\n\n\/* ===== \u65bd\u5de5\u5b9e\u666f\u6ed1\u5757\uff08\u6a2a\u5411\u6ed1\u52a8 \u00b7 scroll-snap\uff09 ===== *\/\n.lm-slider-wrap{overflow-x:auto;scroll-snap-type:x mandatory;-webkit-overflow-scrolling:touch;margin:24px 0 10px;padding:0 0 8px}\n.lm-slider-wrap::-webkit-scrollbar{height:4px}\n.lm-slider-wrap::-webkit-scrollbar-thumb{background:#ddd;border-radius:4px}\n.lm-slider-track{display:flex;gap:12px}\n.lm-slider-card{flex:0 0 260px;scroll-snap-align:start;margin:0}\n.lm-slider-card img{width:100%;height:180px;object-fit:cover;border-radius:8px;transition:.3s;display:block}\n.lm-slider-card img:hover{transform:scale(1.03);box-shadow:0 4px 14px rgba(0,0,0,.15)}\n.lm-slider-card figcaption{font-size:.8rem;color:#666;text-align:center;margin-top:6px}\n\n\/* ===== \u7cbe\u5de5\u516b\u9636\u6bb5 ===== *\/\n.lm-steps{display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin-top:20px}\n.lm-step{text-align:center;padding:16px 10px;background:#f8f9fa;border-radius:10px;border:1px solid #e8e8e8}\n.lm-step .lm-num{width:34px;height:34px;line-height:34px;border-radius:50%;background:var(--lm-blue);color:#fff;font-weight:700;margin:0 auto 8px}\n.lm-step p{font-size:.82rem;color:#666}\n\n\/* ===== \u5ef6\u4f38\u9605\u8bfb ===== *\/\n.lm-link-cards{display:grid;grid-template-columns:repeat(auto-fill,minmax(300px,1fr));gap:14px}\n.lm-link-card{display:block;text-decoration:none;border:1px solid #e5e5e5;border-radius:10px;padding:16px 18px;background:#fff;transition:.25s}\n.lm-link-card:hover{border-color:var(--lm-blue);box-shadow:0 4px 14px rgba(0,0,0,.1);transform:translateY(-2px)}\n.lm-link-card .lm-title{color:var(--lm-blue);font-weight:700;font-size:.95rem;display:block;margin-bottom:5px}\n.lm-link-card .lm-desc{color:#777;font-size:.83rem}\n\n\/* ===== FAQ\uff08\u8bed\u4e49\u5316 details\/summary\uff09 ===== *\/\n.lm-faq-item{border:1px solid #eee;border-radius:10px;margin-bottom:12px;overflow:hidden}\n.lm-faq-item summary{padding:16px 20px;cursor:pointer;font-weight:600;color:#333;font-size:.95rem;list-style:none;position:relative;padding-right:40px}\n.lm-faq-item summary::-webkit-details-marker{display:none}\n.lm-faq-item summary::after{content:\"+\";position:absolute;right:18px;top:14px;color:var(--lm-red);font-size:1.2rem}\n.lm-faq-item[open] summary::after{content:\"\u2212\"}\n.lm-faq-item .lm-faq-a{padding:0 20px 16px;font-size:.9rem;color:#555}\n\n\/* ===== \u95e8\u5e97 ===== *\/\n.lm-store-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:16px 0}\n.lm-store{background:#fafafa;border:1px solid #eee;border-radius:10px;padding:12px 14px}\n.lm-store img{width:100%;border-radius:8px}\n.lm-st-name{font-weight:700;color:var(--lm-red);margin:8px 0 4px}\n.lm-store p{font-size:.84rem;color:#666}\n.lm-store a{color:var(--lm-blue);text-decoration:none}\n\n\/* ===== CTA ===== *\/\n.lm-cta{background:linear-gradient(135deg,#1a3a6e,#2c5aa0);border-radius:14px;padding:32px;color:#fff;text-align:center;margin:20px 0}\n.lm-cta h3{font-size:1.25rem;margin-bottom:8px}\n.lm-cta p{font-size:.92rem;opacity:.95;margin:4px 0}\n.lm-cta a{color:#ffd700;text-decoration:none;font-weight:700}\n.lm-btn{display:inline-block;background:#ffd700;color:#1a3a6e;font-weight:700;padding:12px 30px;border-radius:8px;text-decoration:none;margin-top:14px;transition:.25s}\n.lm-btn:hover{transform:translateY(-2px);box-shadow:0 4px 12px rgba(0,0,0,.2)}\n\n\/* ===== \u9875\u811a ===== *\/\nfooter{background:#14284d;color:#aaa;padding:40px 20px;text-align:center;font-size:.82rem;line-height:2}\nfooter a{color:#8ab4f8;text-decoration:none}\n\n\/* ===== \u54cd\u5e94\u5f0f ===== *\/\n@media(max-width:768px){.lm-grid-2,.lm-grid-3,.lm-xgeo-inner,.lm-store-grid{grid-template-columns:1fr}.lm-slider-card{flex-basis:72%}.lm-steps{grid-template-columns:repeat(2,1fr)}.lm-hero h1{font-size:1.5rem}}\n<\/style>\n\n<div class=\"lm-hero\" data-page-node-id=\"q7753iUwPha11qyuXgN9nD\">\n  <div data-page-node-id=\"XhWq9sUipFU5PjWJq9AmGy\">\n    <h1 data-page-node-id=\"kTEaKfSBSU7Ds2kEHvFAse\">\u6210\u90fd\u5e02\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6<br data-page-node-id=\"mxXKGMzDSnGP1pJFHsXr66\">\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94 + \u535a\u4e16\u51b7\u51dd\u7089+\u8282\u80fd\u8bbe\u8ba1\u5730\u6696<\/h1>\n    <p class=\"lm-sub\" data-page-node-id=\"38SXGIfwqXyZD6JZ30uK16\">99\u33a1\u4e09\u5ba4\u4e24\u5385 \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u5168\u5c4b\u8212\u9002\u7cfb\u7edf \u00b7 \u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5<\/p>\n    <span class=\"lm-tag\" data-page-node-id=\"JjZ7T8ST36lKBprvC73Eb2\">\ud83c\udf06 \u6210\u90fd \u00b7 \u6210\u534e\u533a \u00b7 \u7eff\u57ce\u9526\u56ed<\/span>\n  <\/div>\n<\/div>\n\n<nav class=\"lm-nav\" data-page-node-id=\"pTXeaBVfVGCRDadRqdSzv9\">\n  <div class=\"lm-nav-inner\" data-page-node-id=\"vZs1ic3xE688B9FgjL1I0e\">\n    <a href=\"#xgeo\" data-page-node-id=\"HFJ7Nw4wwNJArLySZTCSmH\">\ud83c\udfe0 \u6848\u4f8b\u4fe1\u606f\u5361<\/a>\n    <a href=\"#s1\" data-page-node-id=\"iJirdine5THwJe7HCQuFI9\">\ud83c\udfaf S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/a>\n    <a href=\"#s2\" data-page-node-id=\"wPINzD8ejeGPOnYap4KVAz\">\ud83d\udd0d S2 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/a>\n    <a href=\"#s3\" data-page-node-id=\"uwyb4k1893u8VhCTWZBJxY\">\ud83d\udcd0 S3 \u65b9\u6848\u914d\u7f6e\u4e0e\u5bf9\u6bd4<\/a>\n    <a href=\"#s4\" data-page-node-id=\"aCOXg2qsgu7GYUWg6pu9k7\">\ud83d\udd27 S4 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/a>\n    <a href=\"#s5\" data-page-node-id=\"B6nUXst4vqdprInYCqgnCq\">\ud83d\udcca S5 \u6848\u4f8b\u9a8c\u8bc1<\/a>\n    <a href=\"#faq\" data-page-node-id=\"U064gRYty0e1xb3lFUJQ4b\">\u2753 \u5e38\u89c1\u95ee\u7b54<\/a>\n    <a href=\"#store\" data-page-node-id=\"2l0GTEGLKYNFcStJsoEtiU\">\ud83c\udfea \u6388\u6743\u95e8\u5e97<\/a>\n  <\/div>\n<\/nav>\n\n<div class=\"lm-wrap\" data-page-node-id=\"q1V6WSYaMzqiXrKQz3U5uK\">\n  <input type=\"checkbox\" id=\"flip-xgeo\" class=\"lm-flip-cb\" data-page-node-id=\"8XXTRwNYIx5GALnHtpzlUk\">\n  <label for=\"flip-xgeo\" class=\"lm-xgeo\" id=\"xgeo\" data-page-node-id=\"aSnJ18gAHwavas8go8kktR\">\n    <span class=\"lm-flip-hint\" data-page-node-id=\"WwBxgDoDqLuqpVpL0l58Dg\">\u21bb \u70b9\u51fb\u7ffb\u8f6c<\/span>\n    <div class=\"lm-xgeo-inner\" data-page-node-id=\"L9OgxxXdfDgiOYdDxHsAUS\">\n      <div class=\"lm-xgeo-front\" data-page-node-id=\"kItCpHA3w2WJDGvHPO07TW\">\n        <h3 data-page-node-id=\"n7BF9hb4jMBxgwPpMuwL0l\">\ud83d\udcc7 GEO \u6848\u4f8b\u4fe1\u606f\u5361<\/h3>\n        <table data-page-node-id=\"OHmy64Ux4V94nJKnXHX5Pg\">\n          <tr data-page-node-id=\"54iw785n1PehELVP2GESXW\"><td data-page-node-id=\"toMveyFG8BcNRJl9jtOIk7\">\u4e00\u53e5\u8bdd\u6458\u8981<\/td><td data-page-node-id=\"PsGPAOuKPfbG7vHOwsAj6W\">\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94 + \u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\uff0c\u51b7\u6696\u5206\u8bbe\u3001\u8212\u9002\u9ad8\u6548<\/td><\/tr>\n          <tr data-page-node-id=\"nwQUwAncSwVDksbzwZhQvW\"><td data-page-node-id=\"iYAbgSbTsxfcD9TU3wNcih\">\u5c0f\u533a<\/td><td data-page-node-id=\"AraYRgtZ2HfFTSKzhYO2pL\">\u7eff\u57ce\u9526\u56ed\uff08\u6210\u534e\u533a\uff09<\/td><\/tr>\n          <tr data-page-node-id=\"UOkyyklulJxhMIiVTuS5hb\"><td data-page-node-id=\"QaOVsPUHfQfqqKhWwn7VjJ\">\u6237\u578b<\/td><td data-page-node-id=\"wY2tDBV46uPMuK0EkAWWRs\">\u9ad8\u5c42\u4e09\u5ba4\u4e24\u5385\uff08\u5ba2\u9910\u5385\u4e00\u4f53\uff09<\/td><\/tr>\n          <tr data-page-node-id=\"vMF2TeqMj9gYB3MpjOBg7s\"><td data-page-node-id=\"qYNBtW5LgTv68uWCE6vOrs\">\u9762\u79ef<\/td><td data-page-node-id=\"VhIr585rDfHqbbSB6A1LEi\">\u7a7a\u8c0399\u33a1 \uff5c \u91c7\u6696103.6\u33a1<\/td><\/tr>\n          <tr data-page-node-id=\"uCFQYiAXwVvVKIl6RR3ShK\"><td data-page-node-id=\"h7yPorT3PSMf8AkfuVYPuc\">\u70ed\u6e90<\/td><td data-page-node-id=\"xUGl9LqfpwzNCibylSuaks\">\u535a\u4e16 Condens-C3260w-25kW \u51b7\u51dd\u7089<\/td><\/tr>\n          <tr data-page-node-id=\"S4uHspNpAvkmshlyRBCTuF\"><td data-page-node-id=\"Spk8pXYrP5WGdCkf4z4cXX\">\u8f93\u914d<\/td><td data-page-node-id=\"Jrml9TxCrOMvGlTAIPq4GF\">\u4f1f\u661fPE-RT\u5730\u6696\u76d8\u7ba1 + \u5206\u96c6\u6c34\u5668<\/td><\/tr>\n          <tr data-page-node-id=\"zlDBUBjQmxFOMCj4vRuACh\"><td data-page-node-id=\"jvoMlPV5BjQK1D0QwduOg5\">\u672b\u7aef<\/td><td data-page-node-id=\"pdXEGKuygsuNeTWQvwzlTn\">\u65e5\u7acb\u8212\u4eab\u51c0\u5316\u5185\u673a + \u5730\u6696\u76d8\u7ba1<\/td><\/tr>\n          <tr data-page-node-id=\"FzBVEBwPrlHJAeckPGErMC\"><td data-page-node-id=\"SGDQH65wlFl0Od4iJkL05e\">\u63a7\u5236<\/td><td data-page-node-id=\"f8enfNriJZ7l1Gbp4FbqTb\">\u65e5\u7acbWiFi\u7ebf\u63a7\u5668 + \u66fc\u745e\u5fb7\u5ba4\u6e29\u8054\u52a8<\/td><\/tr>\n          <tr data-page-node-id=\"p7NT2PeEuYwnRQQCNgSdS3\"><td data-page-node-id=\"XToBOZftgAAWC6dwopX9cf\">\u65bd\u5de5\u65b9<\/td><td data-page-node-id=\"uDekHiLrx66zlYqFHJKa3Q\">\u9f99\u8109\u6696\u901a\uff08\u6210\u90fd22\u5e74\uff09<\/td><\/tr>\n        <\/table>\n      <\/div>\n      <div class=\"lm-xgeo-back\" data-page-node-id=\"U6O3PqpZVJwZf0PEAL2dok\">\n        <h3 data-page-node-id=\"w8OkF7DNv0SEKBf8BmqcGQ\">\ud83d\udcc7 \u6848\u4f8b\u8be6\u60c5\uff08\u53cd\u9762\uff09<\/h3>\n        <table data-page-node-id=\"bj7pwx9zaiQmQkKYYfYKYb\">\n          <tr data-page-node-id=\"45CO71CCBuklhwLXeOa5if\"><td data-page-node-id=\"gFxoxqNwgeXF2ZoiOQIndO\">\u670d\u52a1\u5185\u5bb9<\/td><td data-page-node-id=\"Z2bvc5oq5mXCbpU2TwB53d\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u4e94 + \u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696<\/td><\/tr>\n          <tr data-page-node-id=\"UbImMh482Nsis2gHln7kbt\"><td data-page-node-id=\"YIqZqJVU85GSC8pIICHUve\">\u65bd\u5de5\u5468\u671f<\/td><td data-page-node-id=\"skIjGYYZQdvVLRUxcwFo1o\">\u7a7a\u8c03\u5b89\u88c53-5\u5929 + \u5730\u6696\u94fa\u8bbe2-3\u5929\uff08\u4ea4\u53c9\u65bd\u5de5\uff09<\/td><\/tr>\n          <tr data-page-node-id=\"BUD2tXcvZDS6kxcG3AFsdF\"><td data-page-node-id=\"tCDR8EG4IcBPuUMm7hQiLP\">\u9a8c\u6536\u6807\u51c6<\/td><td data-page-node-id=\"aPANNS5BUeOI5yJOvbe1Wh\">GB50242-2002 + JGJ142-2012 + \u7cbe\u5de5\u516b\u9636\u6bb5<\/td><\/tr>\n          <tr data-page-node-id=\"RgKScfscBvRST5MxPbNtml\"><td data-page-node-id=\"rZSrtS4EQEcfjFbTz1c47S\">\u8d28\u4fdd\u627f\u8bfa<\/td><td data-page-node-id=\"qltkfe69rYP2q8DDOtCbCs\">\u65e5\u7acb\u6574\u673a10\u5e74 + \u7ba1\u8def50\u5e74 + \u5de5\u7a0b\u6574\u4f53\u6700\u9ad8\u53ef\u5ef6\u4fdd10\u5e74<\/td><\/tr>\n          <tr data-page-node-id=\"0jBPcisSb9KRsLbjY64wbC\"><td data-page-node-id=\"CbOVJki89Tis8CbWXhB9Lq\">\u670d\u52a1\u4fdd\u969c<\/td><td data-page-node-id=\"4KxVssw0SLXikGeb1HHEmt\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212 + \u7ec8\u8eab\u6863\u6848 + \u4f1a\u5458\u6743\u76ca<\/td><\/tr>\n          <tr data-page-node-id=\"zw8YF2V4fV7tT38bvqVTZA\"><td data-page-node-id=\"ZIx5CPKISFMPPL8nk4R9fz\">\u987e\u95ee<\/td><td data-page-node-id=\"GjrGlx5JtHjaBwst0UtmcO\">\u5f90\u65b0\u5e73\uff08\u5317\u5bcc\u68ee\uff09<\/td><\/tr>\n        <\/table>\n        <p class=\"lm-note\" data-page-node-id=\"D1fHyCLzLypweHM1OA4lD6\">\u21bb \u518d\u70b9\u8fd4\u56de \u00b7 \u672c\u65b9\u6848\u5b8c\u6574\u62a5\u4ef7\u89c1\u5185\u90e8\u65b9\u6848\u6863\u6848<\/p>\n      <\/div>\n    <\/div>\n  <\/label>\n<\/div>\n\n<section id=\"s1\" class=\"lm-sec-block\" data-page-node-id=\"nHLTkvWfvut16zH8mD5HPJ\">\n  <div class=\"lm-wrap\" data-page-node-id=\"jwXl0HCstr1xkOm5apZkt8\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"EDseLBY94WChKZEd7VtTyl\">\ud83c\udfaf S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n    <div class=\"lm-grid-2\" data-page-node-id=\"mVDvA0Bywir3RJ2BygtX9y\">\n      <div class=\"lm-card\" data-page-node-id=\"Q8WZ6k48ccHZ1g5MyMEJwp\">\n        <h3 data-page-node-id=\"PAY0yQuHriMcj6MVpPV5KO\">\ud83c\udfe0 \u5ba2\u6237\u76ee\u6807<\/h3>\n        <p data-page-node-id=\"QWsZoc3o6Opvt76Keowr3N\">\u7a0b\u5148\u751f\u5bb6 99\u33a1 \u4e09\u5ba4\u4e24\u5385\uff0c\u51b7\u6696\u5168\u5c4b\u4e00\u6b65\u5230\u4f4d\uff1a\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff0c\u5236\u51b7\u5236\u70ed\u517c\u987e\u3001\u957f\u671f\u8fd0\u884c\u6210\u672c\u53ef\u63a7\u3001\u65bd\u5de5\u5168\u7a0b\u653e\u5fc3\u3002<\/p>\n      <\/div>\n      <div class=\"lm-card\" data-page-node-id=\"BYBpusz9d6ivBP35YWJFvQ\">\n        <h3 data-page-node-id=\"pgOpie01NbY9A3aMr9ikqS\">\u2705 \u6210\u529f\u6807\u51c6<\/h3>\n        <p data-page-node-id=\"F4CbCUa0DLUhwGViZj6SeM\">\u2460 \u5ba2\u9910\u5385 57\u33a1 \u5747\u5300\u5236\u51b7\u3001\u566a\u97f3\u5206\u6563\uff1b\u2461 \u51ac\u5b63\u5168\u5c4b 103.6\u33a1 \u5730\u6696\u5feb\u901f\u5347\u6e29\u3001\u8282\u80fd\u7701\u6c14\uff1b\u2462 \u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u9a8c\u6536\u3001\u5168\u7a0b\u53ef\u8ffd\u6eaf\uff1b\u2463 \u7eb3\u5165 10 \u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff0c\u957f\u671f\u6709\u4eba\u7ba1\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"s2\" class=\"lm-sec-block\" data-page-node-id=\"ILMxHgCsdpZ2wH3ETZ4csz\">\n  <div class=\"lm-wrap\" data-page-node-id=\"H23H4tMaKMG0IN6Rc1GiQy\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"mH5gJtwDAHLZEIrGx4SYNy\">\ud83d\udd0d S2 \u00b7 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/h2>\n    <div class=\"lm-grid-2\" data-page-node-id=\"prHFdUXrtOMXqSNgv7Gtm5\">\n      <div class=\"lm-card\" data-page-node-id=\"0sr4cpQCUm9aERA14TYAyJ\">\n        <h3 data-page-node-id=\"bo9mnowF16jLzOxrzddpvF\">\u2744\ufe0f \u5168\u5c4b\u4e2d\u592e\u7a7a\u8c03<\/h3>\n        <p data-page-node-id=\"LQyTFqtoMG7qKlJKXFqOq3\">\u5ba2\u9910\u5385+\u4e3b\u5367+\u6b21\u5367+\u4e66\u623f\u56db\u7a7a\u95f4\u5168\u8986\u76d6\u3002\u5ba2\u9910\u538557\u33a1\u5927\u7a7a\u95f4\u8981\u6c42\u5236\u51b7\u5747\u5300\u3001\u566a\u97f3\u5206\u6563\uff0c\u5c45\u4f4f\u8212\u9002\u5ea6\u4f18\u5148\u3002<\/p>\n      <\/div>\n      <div class=\"lm-card\" data-page-node-id=\"sI7O7uizP1QAHnGzn5Pb1r\">\n        <h3 data-page-node-id=\"Z36lIyTQOwGs6SyETM8Y7n\">\ud83d\udd25 \u5730\u6696\u91c7\u6696<\/h3>\n        <p data-page-node-id=\"9XKo29BfrAHBlE8WdqIXuQ\">\u6210\u90fd\u6e7f\u51b7\u6c14\u5019\uff0c\u5168\u5c4b103.6\u33a1\u5730\u6696\u91c7\u6696\u9700\u6c42\u3002\u9009\u7528\u8282\u80fd\u8bbe\u8ba1\u6863\uff1a\u52a0\u539a\u4fdd\u6e29\u5c42+\u5206\u5ba4\u6e29\u63a7\uff0c\u957f\u671f\u7701\u71c3\u6c14\u3002<\/p>\n      <\/div>\n    <\/div>\n    <div class=\"lm-grid-3 lm-mt\" data-page-node-id=\"QyBV2LHzvEu9rPlhF7Kvbi\">\n      <div class=\"lm-card\" data-page-node-id=\"MoMLODOleDlFg4pks4rR5e\"><h3 data-page-node-id=\"zFUHfYhEoJjJA4AUC5T8mp\">\ud83d\udca1 \u75db\u70b9\u4e00\uff1a\u6015\u566a\u97f3<\/h3><p data-page-node-id=\"nUCpmSXjC9OCuIXg8LSzGd\">\u53cc\u5185\u673a\u5206\u533a + \u8212\u4eab\u7cfb\u521717dB\u9759\u97f3\u5185\u673a\uff0c\u5ba2\u5385\u96c6\u4e2d\u5236\u51b7\u65f6\u566a\u97f3\u5206\u6563\uff0c\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u8fd0\u884c\u3002<\/p><\/div>\n      <div class=\"lm-card\" data-page-node-id=\"ZC5iFrW6yedaEuqClyLKRc\"><h3 data-page-node-id=\"4SwvNlMM1xJbHJs7E8iDTm\">\ud83d\udca1 \u75db\u70b9\u4e8c\uff1a\u6015\u80fd\u8017\u9ad8<\/h3><p data-page-node-id=\"NsMIujzgbW5BVkRHRa1Q0H\">\u8212\u4eab\u5168\u76f4\u6d41\u53d8\u9891 + \u51b7\u51dd\u7089\u70ed\u6548\u7387\u2265105%\uff0c20\u5e74\u89c6\u89d2\u5e74\u8fd0\u884c\u6210\u672c\u66f4\u4f18\uff0c10\u5e74\u80fd\u8017\u8ddf\u8e2a\u4fdd\u969c\u3002<\/p><\/div>\n      <div class=\"lm-card\" data-page-node-id=\"81aqHVks7GDrExvZVEGrRz\"><h3 data-page-node-id=\"D1xN88KHQ64pGOR469WP7i\">\ud83d\udca1 \u75db\u70b9\u4e09\uff1a\u6015\u88c5\u4e0d\u597d<\/h3><p data-page-node-id=\"9O7KEZ5B2wD5O204X1acMf\">\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5 + \u4e09\u65b9\u76d1\u7406 + \u4e91\u7aef\u8bb0\u5f55\uff0c\u9690\u853d\u5de5\u7a0b\u5168\u53ef\u89c6\u5316\u9a8c\u6536\uff0c\u4e0d\u653e\u5fc3\u53ef\u968f\u65f6\u67e5\u770b\u3002<\/p><\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"s3\" class=\"lm-sec-block\" data-page-node-id=\"TCvXpDRSZFmTiQxmO6QVgH\">\n  <div class=\"lm-wrap\" data-page-node-id=\"KEgtbBZyI2IrvCNjb4HNlc\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"4xk2mvIsq6tacJBAmhayKC\">\ud83d\udcd0 S3 \u00b7 \u65b9\u6848\u914d\u7f6e\u4e0e\u5bf9\u6bd4<\/h2>\n    <div class=\"lm-grid-2\" data-page-node-id=\"dqxHEPzwVziYfVsntHjSaX\">\n      <div class=\"lm-card\" data-page-node-id=\"YZexfasmMXXfHHNNwyN8l7\">\n        <h3 data-page-node-id=\"loAiIBlNKQqkdhJUItqKXi\">\u2744\ufe0f \u7a7a\u8c03\u7cfb\u7edf \u00b7 \u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94<\/h3>\n        <p data-page-node-id=\"9VWWHIFa2JrfLhzkQWnC0d\"><strong data-page-node-id=\"VHuO3KcHZbA83jPZXUXP4N\">\u5916\u673a\uff1a<\/strong>\u8212\u4eab RAS-160HRNAQ\uff0816.0kW \u5355\u98ce\u6247\uff09<\/p>\n        <p data-page-node-id=\"l0f7FSpNnSTs7jLE62x4Mt\"><strong data-page-node-id=\"9syJ5nqoCiiMM5nBuBTJpF\">\u5ba2\u9910\u5385\uff1a<\/strong>71\u578b + 25\u578b\u53cc\u5185\u673a\uff08\u5206\u533a\u63a7\u6e29\uff0c\u4eba\u5c11\u5f0025\u66f4\u7701\u7535\uff09<\/p>\n        <p data-page-node-id=\"kTNEARvbkFc0H3OL5gl6aG\"><strong data-page-node-id=\"S75In4q2yyzlkn25Ta3BkU\">\u4e3b\u5367\uff1a<\/strong>40\u578b \uff5c <strong data-page-node-id=\"AXQswNNE98kolUUKCv6dUG\">\u6b21\u5367\uff1a<\/strong>18\u578b \uff5c <strong data-page-node-id=\"hCKkBGIh9GYFJ2QTlypHES\">\u4e66\u623f\uff1a<\/strong>18\u578b<\/p>\n        <p style=\"margin-top:8px\" data-page-node-id=\"zontu5pqtwNQLAU98Qc7sg\">\u8fde\u63a5\u7387123.75%\uff08\u2264130%\u5408\u89c4\uff09\uff0c160\u4e3b\u673a\u90e8\u5206\u8d1f\u8377\u4f4e\u9891\u8fd0\u884c\u66f4\u7701\u7535\u3002<\/p>\n      <\/div>\n      <div class=\"lm-card\" data-page-node-id=\"rLeJLO3wH7YSZHDwuiYWMu\">\n        <h3 data-page-node-id=\"UGaYdJQMo46bdFGfr5IiuP\">\ud83d\udd25 \u5730\u6696\u7cfb\u7edf \u00b7 \u535a\u4e16\u51b7\u51dd\u7089 + \u8282\u80fd\u8bbe\u8ba1<\/h3>\n        <p data-page-node-id=\"3sKup2VIYbytUi0j08Umm9\"><strong data-page-node-id=\"HNQ3h01igJ9EiI5MTacArK\">\u70ed\u6e90\uff1a<\/strong>\u535a\u4e16 Condens-C3260w-25kW \u51b7\u51dd\u7089\uff08\u70ed\u6548\u7387\u2265105%\uff09<\/p>\n        <p data-page-node-id=\"Xx1tgA403rdrg3EDUDA6bM\"><strong data-page-node-id=\"PqSYuShmb7rSW1saz76r93\">\u76d8\u7ba1\uff1a<\/strong>\u4f1f\u661fPE-RT\u5730\u6696\u7ba1\uff08\u95f4\u8ddd\u2264150mm\uff09<\/p>\n        <p data-page-node-id=\"vTNBfif4gClzpLGFjnfOWE\"><strong data-page-node-id=\"ggeNIL4QQq082maprIi27t\">\u4fdd\u6e29\uff1a<\/strong>\u52a0\u539a\u4fdd\u6e29\u5c42 + \u8fb9\u754c\u4fdd\u6e29\u6761 + \u53cd\u5c04\u819c<\/p>\n        <p data-page-node-id=\"ivMWFydKZhAD7WfYnEEYEd\"><strong data-page-node-id=\"0rQp6usHUeplhMJjobd9df\">\u63a7\u5236\uff1a<\/strong>\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7 + \u5ba4\u6e29\u8054\u52a8\u9505\u7089\uff08H-BOX\uff09<\/p>\n      <\/div>\n    <\/div>\n    <div class=\"lm-card lm-mt\" data-page-node-id=\"cJtngtIJGLU9ksoGgKREEH\">\n      <h3 data-page-node-id=\"IWEH8FqQySRrKiD0YcaxlY\">\ud83d\udcdd \u8bbe\u8ba1\u4eae\u70b9<\/h3>\n      <p data-page-node-id=\"5V3aqsBA5HublthMEH3ZwY\">\u2460 \u51b7\u6696\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u4e92\u4e0d\u8026\u5408\uff0c\u5404\u81ea\u9ad8\u6548\uff1b\u2461 \u5ba2\u9910\u5385\u53cc\u5185\u673a\u5206\u533a\uff0c\u517c\u987e\u8282\u80fd\u4e0e\u8212\u9002\uff1b\u2462 \u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c35-45\u2103\u4f9b\u6c34\uff0c\u8282\u80fd\u7701\u6c14\uff1b\u2463 \u4e09\u65b9\u8054\u4fdd\uff08\u9f99\u8109+\u4f1f\u661f+\u4e2d\u56fd\u4eba\u4fdd\uff0950\u5e74\u7ba1\u8def\u8d28\u4fdd\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"s4\" class=\"lm-sec-block\" data-page-node-id=\"v799BOVnqse60GG0arDRuy\">\n  <div class=\"lm-wrap\" data-page-node-id=\"VvYgQaWuA1ZfAr9JLg7DbP\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"wsO2fVGawtXo5sYy3DHlVW\">\ud83d\udd27 S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/h2>\n    <p class=\"lm-lead\" data-page-node-id=\"3aK2ZnptSlDyCIWZZsRT3t\">\u4ece\u6750\u6599\u8fdb\u573a\u5230\u4ea4\u4ed8\u6559\u5b66\uff0c\u6bcf\u9053\u5de5\u5e8f\u62cd\u7167\u5b58\u6863\uff0c\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u9a8c\u6536\uff0c\u5168\u7a0b\u53ef\u8ffd\u6eaf\u3002<\/p>\n    <div class=\"lm-steps\" data-page-node-id=\"TjLSilIJZ2iPCAHUNXU1pB\">\n      <div class=\"lm-step\" data-page-node-id=\"BzJFYSh8CQEFYmGNt9ncrj\"><div class=\"lm-num\" data-page-node-id=\"mRBDx2UWcni8AEqH1bfA4n\">1<\/div><p data-page-node-id=\"atCMWK7Da9D5EeJSdIqPl6\">\u6750\u6599\u8fdb\u573a<br data-page-node-id=\"3p7U68V7l1KJwhs9ZD37fE\">\u6838\u9a8c\u54c1\u724c\u578b\u53f7<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"n6FJQZRjda456Y34lKOFIE\"><div class=\"lm-num\" data-page-node-id=\"EZEWNqAMMMmdFWzxvPs1l2\">2<\/div><p data-page-node-id=\"6bI7FnxGt8ganYKSjwj5Do\">\u5185\u673a\u5b89\u88c5<br data-page-node-id=\"Nn6bPSv0ArPJ4HkkFkT0eU\">\u53cc\u51cf\u9707\u5de5\u827a<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"8My04OpRTUnUAkLjaYuUna\"><div class=\"lm-num\" data-page-node-id=\"Uz42XO93GjHP56ZRHn72Av\">3<\/div><p data-page-node-id=\"kndZPLDbUPj3sRimEItKc0\">\u94dc\u7ba1\u710a\u63a5<br data-page-node-id=\"GYf2fMcNBRRT3Leeb7EMcT\">\u6c2e\u6c14\u4fdd\u62a4\u710a<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"cXEiiSizpYmeVNwlKuHIYr\"><div class=\"lm-num\" data-page-node-id=\"6nW3rEuWoNox2r6v48wCFw\">4<\/div><p data-page-node-id=\"PvWa0Veyk1zNCorQyPPi5c\">\u6c2e\u6c14\u4fdd\u538b<br data-page-node-id=\"pc8ckX8tGDkDfTe8FAV9Cq\">4.15MPa\/24h<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"lRc3AK5BF6fX3qWoPlYnGD\"><div class=\"lm-num\" data-page-node-id=\"86SxRjhTcLk1mPlenO2FKX\">5<\/div><p data-page-node-id=\"TZ0ThzlQVOyVOHuK9157MO\">\u5730\u6696\u76d8\u7ba1<br data-page-node-id=\"HSBmKOryRlt4zIRSBnm0Aq\">\u95f4\u8ddd\u2264150mm<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"yhhvNucBzmZjWAxfygRh8N\"><div class=\"lm-num\" data-page-node-id=\"lnbrXfP87BYTdY2HFd2q12\">6<\/div><p data-page-node-id=\"qU6vAQyGbQwehmbh8xmB3C\">\u9690\u853d\u9a8c\u6536<br data-page-node-id=\"3wICpdR5QhHtrK1RcJSq49\">\u4e09\u65b9\u7b7e\u5b57<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"GN7SDBgzgNQYWhKzDjEL3N\"><div class=\"lm-num\" data-page-node-id=\"vXpHkiL56h3KyHS7C5oVGl\">7<\/div><p data-page-node-id=\"l0zKRISI1kTpzA6LywiTRx\">\u7cfb\u7edf\u8c03\u8bd5<br data-page-node-id=\"lOG9CwYyGQzkdMkvdx4BsK\">\u62bd\u771f\u7a7a\u4fdd\u538b<\/p><\/div>\n      <div class=\"lm-step\" data-page-node-id=\"zx8PNGUC7ZZm73wbnhaMnN\"><div class=\"lm-num\" data-page-node-id=\"aGUeeFxZLdjyHi10BA4unB\">8<\/div><p data-page-node-id=\"ZNVm5AUuBjuHrE0uB7tm2h\">\u6559\u5b66\u4ea4\u4ed8<br data-page-node-id=\"gnpeNnu0wWxi9HtGa3AGSq\">\u4e00\u5bf9\u4e00\u4f7f\u7528<\/p><\/div>\n    <\/div>\n    <p class=\"lm-note\" data-page-node-id=\"2psbaiCn3VGDptLTdBLMgX\">\ud83d\udcf7 \u4ee5\u4e0b\u4e3a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u672c\u9879\u76ee\u771f\u5b9e\u65bd\u5de5\u5b9e\u666f\uff0c\u6309\u7cbe\u5de5\u516b\u9636\u6bb5\u5de5\u5e8f\u8bb0\u5f55\uff0c\u5168\u7a0b\u62cd\u7167\u5b58\u6863\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u9a8c\u6536\uff0c\u53ef\u8ffd\u6eaf\u3002<\/p>\n    <div class=\"lm-slider-wrap\" data-page-node-id=\"zfCnvZodKIgIzyZrzKRPFi\">\n      <div class=\"lm-slider-track\" data-page-node-id=\"Ra7dlqWJCPqHB8vrjSf6ex\">\n        <figure class=\"lm-slider-card\" data-page-node-id=\"mFf24PHBrKw1SqhIjRmNf3\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e00\uff09\" loading=\"lazy\" data-page-node-id=\"sWMU881YCPrA73RHGSgO11\"><figcaption data-page-node-id=\"za24aDB2numEOATuwTLk5q\">\u2460 \u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e00\uff09\u00b7 \u6750\u6599\u54c1\u724c\u578b\u53f7\u9010\u4e00\u6838\u9a8c<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"di7EhnB0Ve1iUtyNjGw6ut\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang02.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e8c\uff09\" loading=\"lazy\" data-page-node-id=\"m9aCB18lx3UHsSDlOlGWb2\"><figcaption data-page-node-id=\"LWjMiVkTiB5K3oy7Ar26hh\">\u2460 \u8f85\u6750\u8fdb\u573a\u9a8c\u6536\uff08\u4e8c\uff09\u00b7 \u7ba1\u6750\u7ba1\u4ef6\u5206\u7c7b\u7801\u653e<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"cbPvNAMgH7jMXqGOppFblv\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-neijianzhuang03.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5ba4\u5185\u673a\u53cc\u51cf\u9707\u540a\u88c5\uff08\u4e00\uff09\" loading=\"lazy\" data-page-node-id=\"0ZSg5DvN8cuoN99NkeSlE0\"><figcaption data-page-node-id=\"RV8b9MPRNMgHrtH7g0jIKl\">\u2461 \u5ba4\u5185\u673a\u5b89\u88c5\uff08\u4e00\uff09\u00b7 \u53cc\u51cf\u9707\u540a\u88c5\u3001\u6c34\u5e73\u5b9a\u4f4d<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"kmEhc1ulJpd6CHExdZriFV\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-neijianzhuang04.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5ba4\u5185\u673a\u53cc\u51cf\u9707\u540a\u88c5\uff08\u4e8c\uff09\" loading=\"lazy\" data-page-node-id=\"2igdKbiomAe6Ae3ZGilcPx\"><figcaption data-page-node-id=\"s5emR2y2gY4DA4p2m2CSQj\">\u2461 \u5ba4\u5185\u673a\u5b89\u88c5\uff08\u4e8c\uff09\u00b7 \u51fa\u56de\u98ce\u53e3\u7559\u4f4d\u7cbe\u51c6<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"DiLp5ovWBp81GbMRpAdBiy\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-danqiguan01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u6c2e\u6c14\u74f6\u5c31\u4f4d\uff08\u710a\u63a5\u4fdd\u62a4\u6c14\u6e90\uff09\" loading=\"lazy\" data-page-node-id=\"aiyro2G4JYsapU0U6r5D3T\"><figcaption data-page-node-id=\"yXH6KYHEMWFBgHdCwHsnuO\">\u2462 \u6c2e\u6c14\u4fdd\u62a4\u710a\u51c6\u5907 \u00b7 \u6c2e\u6c14\u74f6\u5c31\u4f4d\uff08\u710a\u63a5\u9632\u6c27\u5316\u6c14\u6e90\uff09<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"lTDYNfTyfTnEFw7ItYY6Nm\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-danqibaohuhanjie01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\" loading=\"lazy\" data-page-node-id=\"uVg37jt5m4xlAeYejm3Z4K\"><figcaption data-page-node-id=\"AzS7VCxQSq5CyksiVMvOUF\">\u2462 \u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5 \u00b7 \u5145\u6c2e\u710a\u63a5\u675c\u7edd\u6c27\u5316\u76ae<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"OfsgWRU3BEWgmSUlI6IJp6\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-baowenbanpushe01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5730\u6696\u4fdd\u6e29\u677f\u94fa\u8bbe\uff08\u4e00\uff09\" loading=\"lazy\" data-page-node-id=\"B4NDbkp64PRDGPAnNk2ryQ\"><figcaption data-page-node-id=\"ul3ekuWjbWA0CEJvPDgHwR\">\u2463 \u5730\u6696\u4fdd\u6e29\u677f\u94fa\u8bbe\uff08\u4e00\uff09\u00b7 \u6ee1\u94fa\u65e0\u7f1d\u3001\u8fb9\u89d2\u6536\u53e3<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"y4F6HOdowT12otGH2FcTZH\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-baowenbanpushe02.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5730\u6696\u4fdd\u6e29\u677f\u94fa\u8bbe\uff08\u4e8c\uff09\" loading=\"lazy\" data-page-node-id=\"yOa4yadaL5yEjZkRc2ZoA9\"><figcaption data-page-node-id=\"jQu868oN7H2uMEDnVbIrfE\">\u2463 \u5730\u6696\u4fdd\u6e29\u677f\u94fa\u8bbe\uff08\u4e8c\uff09\u00b7 \u9694\u70ed\u5c42\u5e73\u6574\u5c31\u4f4d<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"B44Tvx7Bkn95GtU9mdIA5R\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-panguanpushe01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u4e00\uff09\" loading=\"lazy\" data-page-node-id=\"ftSapoNEw639qde9JAinQG\"><figcaption data-page-node-id=\"ryjICHpQvDIs0xyTCLJFPz\">\u2464 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u4e00\uff09\u00b7 \u95f4\u8ddd\u2264150mm \u5747\u5300\u5e03\u7ba1<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"HSMKHpAeXDAjErHlOH45kZ\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-panguanpushe02.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u4e8c\uff09\" loading=\"lazy\" data-page-node-id=\"7BODTfNP1Q9ZoJq1IgGlSZ\"><figcaption data-page-node-id=\"nARrWsRT3SbMLhH64BxZXY\">\u2464 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u4e8c\uff09\u00b7 \u56de\u5b57\u578b\u8d70\u5411\u4fdd\u6c34\u529b\u5e73\u8861<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"SDj7e2KdqAUOulWz572TM6\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-panguanpushe03.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u4e09\uff09\" loading=\"lazy\" data-page-node-id=\"MhXYtTCJwUqlBttaOMDFOb\"><figcaption data-page-node-id=\"91rSC2bjsmPHhMn5OeVQ3b\">\u2464 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u4e09\uff09\u00b7 \u5206\u96c6\u6c34\u5668\u63a5\u7ba1\u5b9a\u4f4d<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"hCozHGd4wBTGCwEd6IX7ch\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-weiyunuanqipianyuliujiekou01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u5a01\u80fd\u6696\u6c14\u7247\u9884\u7559\u63a5\u53e3\" loading=\"lazy\" data-page-node-id=\"cEXblMLqUC3CSfKK0TEMKC\"><figcaption data-page-node-id=\"O1SKv7a41U8haOmEV2F0H9\">\u2465 \u5a01\u80fd\u6696\u6c14\u7247\u9884\u7559\u63a5\u53e3 \u00b7 \u6df7\u88c5\u7cfb\u7edf\u63d0\u524d\u7559\u4f4d<\/figcaption><\/figure>\n        <figure class=\"lm-slider-card\" data-page-node-id=\"K1EGs8XA3gvH0gv9MOPL4O\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-yalibiao01.jpg\" alt=\"\u7eff\u57ce\u9526\u56ed\u00b7\u7a0b\u5148\u751f \u00b7 \u7cfb\u7edf\u4fdd\u538b\u538b\u529b\u8868\u793a\u610f\" loading=\"lazy\" data-page-node-id=\"YwRhzLQdjJZJZvJp4XAdjv\"><figcaption data-page-node-id=\"HBAkFA8NdOETEQwICTvIHf\">\u2466 \u7cfb\u7edf\u4fdd\u538b \u00b7 \u538b\u529b\u8868\u5b9e\u65f6\u76d1\u6d4b\uff084.15MPa\/24h\uff09<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"s5\" class=\"lm-sec-block\" data-page-node-id=\"3t7Fd9FXoGb8MRHkqh2V5v\">\n  <div class=\"lm-wrap\" data-page-node-id=\"1PkMgAH0HPktsiOZbowfvI\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"TQdBQF7MOqoJt0aEPosKe8\">\ud83d\udcca S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1<\/h2>\n    <div class=\"lm-grid-3\" data-page-node-id=\"Wqsb8QbppeP40AJOHZWVdZ\">\n      <div class=\"lm-card\" data-page-node-id=\"tBU6qZp9Fde8qf6PN0DBFe\"><h3 data-page-node-id=\"0NFG6mfPGHIuoR1tx3BNZX\">\u2744\ufe0f \u5236\u51b7\u4f53\u9a8c<\/h3><p data-page-node-id=\"EWu9V86S2DqATEfjcXEKw8\">\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\uff0c57\u33a1\u7a7a\u95f4\u5747\u5300\u5236\u51b7\uff1b\u8212\u4eab\u6700\u4f4e17dB\u9759\u97f3\uff0c\u5367\u5ba4\u7761\u7720\u65e0\u5fe7\u3002<\/p><\/div>\n      <div class=\"lm-card\" data-page-node-id=\"pK1ECQqRXAmG255x6GnS3c\"><h3 data-page-node-id=\"3EamYg9AxFwg0SK56JVTg8\">\ud83d\udd25 \u91c7\u6696\u4f53\u9a8c<\/h3><p data-page-node-id=\"HeWHVOeuxIAwqPCLuFCfWV\">\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\u6e29\u8db3\u51c9\u9876\uff0c\u535a\u4e16\u51b7\u51dd\u7089105%\u70ed\u6548\u7387\uff0c\u914d\u5408\u5206\u5ba4\u6e29\u63a7\u6309\u9700\u542f\u505c\uff0c\u7701\u6c14\u66f4\u7701\u5fc3\u3002<\/p><\/div>\n      <div class=\"lm-card\" data-page-node-id=\"5ERWRH8s69BivoxzvoWGan\"><h3 data-page-node-id=\"HZeZJA589KgE57QgA5YppC\">\ud83d\udcc8 10\u5e74\u80fd\u6e90\u4fdd\u969c<\/h3><p data-page-node-id=\"wAm1XygoC5HH8QolkC8fvD\">\u81ea\u52a8\u52a0\u516510\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff1a\u5e74\u5ea6\u7528\u6c14\u8ddf\u8e2a+\u540c\u6237\u578b\u5bf9\u6807+\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae\uff0c\u80fd\u8017\u5f02\u5e38\u4e3b\u52a8\u4e0a\u95e8\u3002<\/p><\/div>\n    <\/div>\n    <div class=\"lm-cta\" data-page-node-id=\"VxguZExqunfIOzXSATVDOk\">\n      <h3 data-page-node-id=\"2mjVTn5q3kOaD4ML15WcU4\">\ud83d\udcde \u6210\u90fd\u540c\u6237\u578b\u51b7\u6696\u65b9\u6848\u54a8\u8be2<\/h3>\n      <p data-page-node-id=\"2kJJAIU1S6YywVKOSqtCBi\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \/ \u540c\u6237\u578b\u6848\u4f8b\u53c2\u89c2 \/ \u900f\u660e\u62a5\u4ef7<\/p>\n      <p data-page-node-id=\"YOauZtGuaT0RpYDllWrDHH\"><a href=\"tel:02886131795\" data-page-node-id=\"XO5sZNyDOKa7l2RvMNEuUB\">028-86131795<\/a>\uff08\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff09 \uff5c <a href=\"tel:02865272586\" data-page-node-id=\"707MQBvJWDbRmziOqRBlUY\">028-65272586<\/a>\uff08\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff09<\/p>\n      <p style=\"font-size:.82rem\" data-page-node-id=\"dIF6xNypn3pHlhDdr0sFOX\">\u670d\u52a1\u8303\u56f4\uff1a\u9ad8\u65b0\u3001\u6210\u534e\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u9a7f\u3001\u5929\u5e9c\u65b0\u533a\u3001\u89c6\u9ad8<\/p>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" class=\"lm-btn\" data-page-node-id=\"tMuQI505UJLIPKnFntDeak\">\u67e5\u770b\u66f4\u591a\u5b8c\u5de5\u6848\u4f8b \u2192<\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"faq\" class=\"lm-sec-block\" data-page-node-id=\"y28lRaujMWQqq3yydFU8hT\">\n  <div class=\"lm-wrap\" data-page-node-id=\"GOe4yaeMsTW5DuHtbTVwDj\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"LrOEhCX0A661mOtOLBc35G\">\u2753 \u5e38\u89c1\u95ee\u7b54<\/h2>\n    <details class=\"lm-faq-item\" open data-page-node-id=\"SsE50Ob621BDB7GO4tYlF7\">\n      <summary data-page-node-id=\"DGEgINlATGxCkj7jU1ZEoz\">99\u33a1\u4e09\u5ba4\u4e24\u5385\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u914d\uff1f<\/summary>\n      <div class=\"lm-faq-a\" data-page-node-id=\"5UbsRsPWCEYe4mQZCZOsdG\">\u65e5\u7acb\u8212\u4eab160\uff0816kW\uff09\u4e00\u62d6\u4e94\uff1a\u5ba2\u9910\u538557\u33a1\u752871+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\uff0c\u4e3b\u536740\u578b\u3001\u6b21\u5367\u548c\u4e66\u623f18\u578b\u3002\u8fde\u63a5\u7387123.75%\u5728\u65e5\u7acb\u5408\u89c4\u533a\u95f4\uff08\u2264130%\uff09\uff0c160\u4e3b\u673a\u5339\u914d\u7387\u9ad8\uff0c\u517c\u987e\u8282\u80fd\u4e0e\u8212\u9002\u3002<\/div>\n    <\/details>\n    <details class=\"lm-faq-item\" data-page-node-id=\"1Dx1YEkpWRvjB6Ino0vLo4\">\n      <summary data-page-node-id=\"dfJrYXzwGSiWg9CevgJ2qC\">\u4e3a\u4ec0\u4e48\u5ba2\u9910\u5385\u8981\u653e\u4e24\u53f0\u5185\u673a\uff1f<\/summary>\n      <div class=\"lm-faq-a\" data-page-node-id=\"4XFKCHpbzuWN8myPZ0uXmu\">\u5ba2\u9910\u538557\u33a1\u662f\u5927\u7a7a\u95f4\uff0c71+25\u53cc\u5185\u673a\u5b9e\u73b0\u5206\u533a\u63a7\u6e29\uff1a\u65e5\u5e38\u4eba\u5c11\u53ea\u5f0025\u578b\u66f4\u7701\u7535\uff0c\u5bb6\u5ead\u805a\u4f1a\u53cc\u673a\u534f\u540c\u5feb\u901f\u964d\u6e29\uff0c\u566a\u97f3\u4e5f\u66f4\u5206\u6563\u3002<\/div>\n    <\/details>\n    <details class=\"lm-faq-item\" data-page-node-id=\"wW2GkgQKIv5FgnPgxCVqyH\">\n      <summary data-page-node-id=\"BwQE9hBJFkhwATMtJARIaf\">\u4e2d\u592e\u7a7a\u8c03\u548c\u5730\u6696\u80fd\u540c\u65f6\u88c5\u5417\uff1f<\/summary>\n      <div class=\"lm-faq-a\" data-page-node-id=\"X3fvZvLvg7TAsGMYpCpEOd\">\u53ef\u4ee5\u3002\u672c\u6848\u4f8b\u4e2d\u592e\u7a7a\u8c03+\u58c1\u6302\u7089\u5730\u6696\u5206\u8bbe\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff1a\u65e5\u7acb\u8212\u4eab\u8d1f\u8d23\u5236\u51b7\uff08\u53ca\u5236\u70ed\uff09\uff0c\u535a\u4e16\u51b7\u51dd\u7089\u8d1f\u8d23\u5730\u6696\u91c7\u6696\uff0c\u4e92\u4e0d\u8026\u5408\u3001\u5404\u81ea\u9ad8\u6548\uff0c\u7ef4\u62a4\u4e5f\u66f4\u6e05\u6670\u3002<\/div>\n    <\/details>\n    <details class=\"lm-faq-item\" data-page-node-id=\"0Mh03Gns4uYXiLr5xyNp7t\">\n      <summary data-page-node-id=\"XihKUZgK1sO6eElLYmttjr\">\u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696\u8282\u80fd\u6548\u679c\u600e\u4e48\u6837\uff1f<\/summary>\n      <div class=\"lm-faq-a\" data-page-node-id=\"2ad9F9OnvLkvnazHy5wRUY\">\u51b7\u51dd\u7089\u70ed\u6548\u7387\u2265105%\uff0c\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u914d\u5408\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff08\u52a0\u539a\u4fdd\u6e29\u5c42+\u5206\u5ba4\u6e29\u63a7\uff09\uff0c\u6210\u90fd\u91c7\u6696\u5b63\u7efc\u5408\u7528\u6c14\u6210\u672c\u53ef\u518d\u964d25-30%\u3002<\/div>\n    <\/details>\n    <details class=\"lm-faq-item\" data-page-node-id=\"uAg4j3vq3XSb9rmDopCnyR\">\n      <summary data-page-node-id=\"8PyCjtj061ohL4f8ihKzKk\">\u5730\u6696\u65bd\u5de5\u591a\u4e45\u80fd\u5b8c\u6210\uff1f<\/summary>\n      <div class=\"lm-faq-a\" data-page-node-id=\"9Ls2ljKE7BpdkQ632ekIKE\">\u7cbe\u5de5\u516b\u9636\u6bb5\u6807\u51c6\u65bd\u5de5\uff1a\u6750\u6599\u8fdb\u573a\u9a8c\u6536\u2192\u5185\u673a\u5b89\u88c5\u2192\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u21924.15MPa\u4fdd\u538b24\u5c0f\u65f6\u2192\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u9a8c\u6536\u2192\u8c03\u8bd5\u2192\u6559\u5b66\u4ea4\u4ed8\uff0c\u7a7a\u8c03\u4e0e\u5730\u6696\u4ea4\u53c9\u65bd\u5de5\u7ea6\u4e00\u5468\uff0c\u5168\u7a0b\u62cd\u7167\u5b58\u6863\u53ef\u8ffd\u6eaf\u3002<\/div>\n    <\/details>\n  <\/div>\n<\/section>\n\n<section id=\"store\" class=\"lm-sec-block\" data-page-node-id=\"Pduo8aRBH1IStrzpiZozov\">\n  <div class=\"lm-wrap\" data-page-node-id=\"7hFeF3eXBANwHAUx71sTGt\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"sOSoPnWiRg0zeQMHIcp4FK\">\ud83c\udfea \u6388\u6743\u95e8\u5e97 \u00b7 \u6b22\u8fce\u5b9e\u5730\u770b\u6837<\/h2>\n    <div class=\"lm-store-grid\" data-page-node-id=\"HA39x4hN2LujKZVEmDsf7W\">\n      <div class=\"lm-store\" data-page-node-id=\"0FCutHT8kDubDnhTE8rri8\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\u5b9e\u666f\" loading=\"lazy\" data-page-node-id=\"ZjHzDJ1ahGhA36mbeQkq6w\">\n        <div class=\"lm-st-name\" data-page-node-id=\"dwJ5DFPYKQhQeDz0wJZvoy\">\u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/div>\n        <p data-page-node-id=\"cHXpkbICv7gdg4Nf37itnJ\">\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/p>\n        <p data-page-node-id=\"dJGAXZDkfcqkuXVGJHbaUy\">\ud83d\udcde <a href=\"tel:02886131795\" data-page-node-id=\"DiIT6EW9ejOh2obMpK2gZe\">028-86131795<\/a><\/p>\n      <\/div>\n      <div class=\"lm-store\" data-page-node-id=\"ST8Gmi5qqCD4LPtr19tFh3\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\u5b9e\u666f\" loading=\"lazy\" data-page-node-id=\"6gFT93NqX58G35Y5pcsq4N\">\n        <div class=\"lm-st-name\" data-page-node-id=\"PWaxgr0CeoeH9YzLZoPzTT\">\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/div>\n        <p data-page-node-id=\"jMGcbmaYN4cTkv1ASDFVyK\">\u6210\u90fd\u00b7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a<\/p>\n        <p data-page-node-id=\"5jZDmzWKmhiS8beZ3Z1Yjo\">\ud83d\udcde <a href=\"tel:02865272586\" data-page-node-id=\"FSxBaBPrLJZhT5QwvoQ98G\">028-65272586<\/a><\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"more\" class=\"lm-sec-block\" style=\"border-bottom:none\" data-page-node-id=\"ujy9xyWXtnkABDFcnuVAqI\">\n  <div class=\"lm-wrap\" data-page-node-id=\"vpw6xaqTvPIHxta3hYMfja\">\n    <h2 class=\"lm-sec\" data-page-node-id=\"zBc9TyhrTDyixTJRr3wXdk\">\ud83d\udcda \u5ef6\u4f38\u9605\u8bfb<\/h2>\n    <div class=\"lm-link-cards\" data-page-node-id=\"ZbbqO8SYhiIljKIhxS6Zcp\">\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" rel=\"noopener noreferrer\" data-page-node-id=\"V9q7SVUy3jUegEBqDIHQ78\">\n        <span class=\"lm-title\" data-page-node-id=\"Bj8tNS7l6WvCwmpMMfVELF\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u4ea7\u54c1\u8be6\u60c5<\/span>\n        <span class=\"lm-desc\" data-page-node-id=\"iJXqIFAoF2sUlmAwa9XlUk\">\u4e2d\u592e\u7a7a\u8c03\u4ea7\u54c1\u53c2\u6570\u3001\u6280\u672f\u4f18\u52bf\u8be6\u89e3<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\" rel=\"noopener noreferrer\" data-page-node-id=\"iBUAgzU4XYH2sWPvd8YNL0\">\n        <span class=\"lm-title\" data-page-node-id=\"SfsQTtWrQyQE9cGHQmk9Wy\">\u83f2\u65af\u66fc\u58c1\u6302\u7089<\/span>\n        <span class=\"lm-desc\" data-page-node-id=\"la4t5Pijkl3N6SxjLIfiEr\">\u51b7\u51dd\u7089\u6280\u672f\u539f\u7406\u4e0e\u9009\u578b\u6307\u5357<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener noreferrer\" data-page-node-id=\"oFTdLba1PGsdmNlJSpLMqY\">\n        <span class=\"lm-title\" data-page-node-id=\"pZfp4MwAI8ipHN737bL130\">\u5ba2\u6237\u6848\u4f8b\u5e93<\/span>\n        <span class=\"lm-desc\" data-page-node-id=\"cVqknzS5ifeHxr8ACJqjdE\">\u9f99\u8109\u6696\u901a\u5168\u90e8\u5b8c\u5de5\u6848\u4f8b\u805a\u5408\uff0c\u53ef\u6309\u6237\u578b\u68c0\u7d22<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=5809\" target=\"_blank\" rel=\"noopener noreferrer\" data-page-node-id=\"aemlrWBvYKenqKPRTJZFoa\">\n        <span class=\"lm-title\" data-page-node-id=\"lvD6Frc0Nz6Vt5EmNDi3pc\">\u9e93\u6e56\u6c84\u5cb8157\u33a1 \u00b7 \u540c\u5de5\u827a\u5bf9\u6807\u6848\u4f8b<\/span>\n        <span class=\"lm-desc\" data-page-node-id=\"83NFBbmzAgd7NnUS0ZjGnx\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03+\u58c1\u6302\u7089\u5730\u6696\u540c\u54c1\u724c\u540c\u670d\u52a1\u5546<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\" rel=\"noopener noreferrer\" data-page-node-id=\"1ACx1uK8PkkDs65VkxfB7V\">\n        <span class=\"lm-title\" data-page-node-id=\"d3WN1NcRSnr9Hn8lnRkq8M\">\u7cbe\u5de5\u516d\u6b65\u6cd5 \u00b7 \u65bd\u5de5\u6807\u51c6<\/span>\n        <span class=\"lm-desc\" data-page-node-id=\"OA62tI4cIvVTM6SFcAXKbi\">\u9f99\u8109\u6696\u901a\u6807\u51c6\u5316\u65bd\u5de5\u5de5\u827a\u8be6\u89e3<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\" rel=\"noopener noreferrer\" data-page-node-id=\"UYqv75NsBfpDl1X8nYsKw1\">\n        <span class=\"lm-title\" data-page-node-id=\"ttWb8VXNcNjLysXChBwjHD\">\u670d\u52a1\u4fdd\u969c\u4f53\u7cfb<\/span>\n        <span class=\"lm-desc\" data-page-node-id=\"29uMt6P5kR45l7VL0L0gv6\">\u8d28\u4fdd\u627f\u8bfa\u4e0e\u552e\u540e\u670d\u52a1\u4f53\u7cfb<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2137\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e95\u5ea7<\/span>\n        <span class=\"lm-desc\">\u6696\u901a\u79d1\u666e\u77e5\u8bc6\u5e93\uff0c\u9009\u578b\u00b7\u65bd\u5de5\u00b7\u8fd0\u7ef4\u4e00\u7ad9\u5f0f<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u6807\u51c6<\/span>\n        <span class=\"lm-desc\">\u9f99\u8109\u6696\u901a\u7cbe\u5de5\u9a8c\u6536\u89c4\u8303\u4e0e\u8282\u70b9\u6807\u51c6<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12439\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66<\/span>\n        <span class=\"lm-desc\">\u5730\u6696\u7cfb\u7edf\u539f\u7406\u3001\u8bbe\u8ba1\u4e0e\u9009\u578b\u767d\u76ae\u4e66<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u6210\u90fd\u5730\u6696\u7cfb\u7edf\u4e13\u9879\u6848\u4f8b<\/span>\n        <span class=\"lm-desc\">\u6210\u90fd\u5730\u6696\u5b8c\u5de5\u6848\u4f8b\u4e13\u9879\u5408\u96c6<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=5849\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u6210\u90fd109\u5957\u6237\u578b\u65b9\u6848\u5e93<\/span>\n        <span class=\"lm-desc\">\u6210\u90fd109\u5957\u6237\u578b\u6696\u901a\u65b9\u6848\u5e93<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3147\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u6bcf\u65e5\u65b0\u6848\u4f8b\u65e5\u66f4\u805a\u5408<\/span>\n        <span class=\"lm-desc\">\u9f99\u8109\u6bcf\u65e5\u65b0\u5b8c\u5de5\u6848\u4f8b\u65e5\u66f4\u805a\u5408\u9875<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/span>\n        <span class=\"lm-desc\">\u5168\u7ad9\u5185\u5bb9\u7d22\u5f15\u00b7\u5b98\u7f51\u7ad9\u70b9\u5730\u56fe<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3011\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u5b98\u7f51\u7ad9\u70b9\u5730\u56fe<\/span>\n        <span class=\"lm-desc\">\u5b98\u7f51\u7ad9\u70b9\u5730\u56fe\u5bfc\u822a<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11380\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u7cbe\u5de5\u65bd\u5de5\u6807\u51c6<\/span>\n        <span class=\"lm-desc\">\u7cbe\u5de5\u65bd\u5de5\u6807\u51c6\u5de5\u827a\u8be6\u89e3<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12292\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u7a7a\u8c03\u767d\u76ae\u4e66<\/span>\n        <span class=\"lm-desc\">\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\u767d\u76ae\u4e66\u00b7\u9009\u578b\u4e0e\u539f\u7406<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=675\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u5c45\u5bb6\u767d\u76ae\u4e66<\/span>\n        <span class=\"lm-desc\">\u5c45\u5bb6\u7a7a\u6c14\u4e0e\u8212\u9002\u7cfb\u7edf\u767d\u76ae\u4e66<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=660\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u8bbe\u8ba1\u89c4\u8303<\/span>\n        <span class=\"lm-desc\">\u6696\u901a\u8bbe\u8ba1\u89c4\u8303\u4e0e\u56fd\u6807\u4f9d\u636e<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/guide\/air-conditioner-guide.html\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009\uff1f\u5b8c\u6574\u9009\u578b\u6307\u5357<\/span>\n        <span class=\"lm-desc\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5b8c\u6574\u9009\u578b\u6307\u5357<\/span>\n      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u5ef6\u4f38\u9605\u8bfb \u00b7 \u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93 ===== -->\n<section style=\"max-width:1080px;margin:28px auto;padding:0 18px\">\n  <h2 style=\"font-size:20px;color:#1a3a6e;border-left:4px solid #c8102e;padding-left:12px;margin:0 0 14px;font-weight:700\">\u5ef6\u4f38\u9605\u8bfb \u00b7 \u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93<\/h2>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(240px,1fr));gap:12px\">\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12447\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/span>\n        <span class=\"lm-desc\">\u6696\u6c14\u7247\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u9009\u578b\u6307\u5357<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10982\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c\u6307\u5357<\/span>\n        <span class=\"lm-desc\">\u660e\u88c5\u6696\u6c14\u7247\u62a5\u4ef7\u4e0e\u8d39\u7528\u53c2\u8003<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2553\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u83f2\u65af\u66fc\u58c1\u6302\u7089\u4e13\u9898<\/span>\n        <span class=\"lm-desc\">\u83f2\u65af\u66fc\u9505\u7089\u4ea7\u54c1\u4e0e\u6848\u4f8b<\/span>\n      <\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\" rel=\"noopener noreferrer\">\n        <span class=\"lm-title\">\u66fc\u745e\u5fb7\u6696\u6c14\u7247\u4e13\u9898<\/span>\n        <span class=\"lm-desc\">\u66fc\u745e\u5fb7\u6696\u6c14\u7247\u4ea7\u54c1\u4e0e\u6848\u4f8b<\/span>\n      <\/a>\n  <\/div>\n<\/section>\n  <footer data-page-node-id=\"alOYrN5mMpXXZMAGRBkPEw\">\n  <p data-page-node-id=\"bbeWBCe2vF2O6BYiquqlh8\">\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 \u00b7 \u6210\u90fd22\u5e74\u672c\u5730\u6696\u901a\u670d\u52a1\u5546 \uff5c \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546<\/p>\n  <p data-page-node-id=\"Es3GZzDkkMPUudG6SGZ0YO\">\u672c\u6848\u4f8b\u4e3a\u5bf9\u5916\u5b9e\u666f\u5b8c\u5de5\u5ba3\u4f20\u9875 \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=6147\" data-page-node-id=\"AjA52Wa6XEaa2Ke1xEWeD4\">\u67e5\u770b\u672c\u9879\u76ee\u5185\u90e8\u65b9\u6848\u6863\u6848 \u2192<\/a><\/p>\n  <p data-page-node-id=\"YhqUzb5YsJQku750sryMqF\">\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff1a028-86131795 \uff5c \u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff1a028-65272586<\/p>\n  <p data-page-node-id=\"mNlMKNIfCXMgF8gtXRElqR\">\u00a9 2004-2026 \u9f99\u8109\u6696\u901a \u00b7 longmai-nt.com \u00b7 \u8700ICP\u59072026015986\u53f7<\/p>\n<\/footer>\n\n","protected":false},"excerpt":{"rendered":"<p>\u6210\u90fd\u5e02\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":2297,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-9255","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u5168\u5c4b\u51b7\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\u3001\u4e3b\u536740\u578b\u3001\u6b21\u5367\u4e0e\u4e66\u623f\u540418\u578b\uff0c\u8fde\u63a5\u7387123.75%\u5408\u89c4\u8fd0\u884c\uff1b\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u70ed\u6548\u7387\u2265105%\u3001\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u76d1\u7406\u4e91\u7aef\u53ef\u67e5\uff0c\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u3001\u8d28\u4fdd\u900f\u660e\u53ef\u8ffd\u6eaf\uff0c\u4e3a\u540c\u6237\u578b\u51b7\u6696\u4e00\u4f53\u65b9\u6848\u63d0\u4f9b\u771f\u5b9e\u53c2\u8003\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=9255\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u5168\u5c4b\u51b7\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\u3001\u4e3b\u536740\u578b\u3001\u6b21\u5367\u4e0e\u4e66\u623f\u540418\u578b\uff0c\u8fde\u63a5\u7387123.75%\u5408\u89c4\u8fd0\u884c\uff1b\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u70ed\u6548\u7387\u2265105%\u3001\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u76d1\u7406\u4e91\u7aef\u53ef\u67e5\uff0c\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u3001\u8d28\u4fdd\u900f\u660e\u53ef\u8ffd\u6eaf\uff0c\u4e3a\u540c\u6237\u578b\u51b7\u6696\u4e00\u4f53\u65b9\u6848\u63d0\u4f9b\u771f\u5b9e\u53c2\u8003\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=9255\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-28T08:25:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255\",\"name\":\"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/gw-lcjy-cxs-fucaijinchang01.jpg\",\"datePublished\":\"2026-07-31T08:23:17+00:00\",\"dateModified\":\"2026-10-28T08:25:54+00:00\",\"description\":\"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u5168\u5c4b\u51b7\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\u3001\u4e3b\u536740\u578b\u3001\u6b21\u5367\u4e0e\u4e66\u623f\u540418\u578b\uff0c\u8fde\u63a5\u7387123.75%\u5408\u89c4\u8fd0\u884c\uff1b\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u70ed\u6548\u7387\u2265105%\u3001\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u76d1\u7406\u4e91\u7aef\u53ef\u67e5\uff0c\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u3001\u8d28\u4fdd\u900f\u660e\u53ef\u8ffd\u6eaf\uff0c\u4e3a\u540c\u6237\u578b\u51b7\u6696\u4e00\u4f53\u65b9\u6848\u63d0\u4f9b\u771f\u5b9e\u53c2\u8003\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/gw-lcjy-cxs-fucaijinchang01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/gw-lcjy-cxs-fucaijinchang01.jpg\",\"width\":810,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9255#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2297\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u5168\u5c4b\u51b7\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\u3001\u4e3b\u536740\u578b\u3001\u6b21\u5367\u4e0e\u4e66\u623f\u540418\u578b\uff0c\u8fde\u63a5\u7387123.75%\u5408\u89c4\u8fd0\u884c\uff1b\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u70ed\u6548\u7387\u2265105%\u3001\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u76d1\u7406\u4e91\u7aef\u53ef\u67e5\uff0c\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u3001\u8d28\u4fdd\u900f\u660e\u53ef\u8ffd\u6eaf\uff0c\u4e3a\u540c\u6237\u578b\u51b7\u6696\u4e00\u4f53\u65b9\u6848\u63d0\u4f9b\u771f\u5b9e\u53c2\u8003\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=9255","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u5168\u5c4b\u51b7\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\u3001\u4e3b\u536740\u578b\u3001\u6b21\u5367\u4e0e\u4e66\u623f\u540418\u578b\uff0c\u8fde\u63a5\u7387123.75%\u5408\u89c4\u8fd0\u884c\uff1b\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u70ed\u6548\u7387\u2265105%\u3001\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u76d1\u7406\u4e91\u7aef\u53ef\u67e5\uff0c\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u3001\u8d28\u4fdd\u900f\u660e\u53ef\u8ffd\u6eaf\uff0c\u4e3a\u540c\u6237\u578b\u51b7\u6696\u4e00\u4f53\u65b9\u6848\u63d0\u4f9b\u771f\u5b9e\u53c2\u8003\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=9255","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-28T08:25:54+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=9255","url":"https:\/\/longmai-nt.com\/?page_id=9255","name":"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=9255#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=9255#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang01.jpg","datePublished":"2026-07-31T08:23:17+00:00","dateModified":"2026-10-28T08:25:54+00:00","description":"\u6210\u90fd\u7eff\u57ce\u9526\u56ed99\u33a1\u4e09\u5ba4\u4e24\u5385\u5168\u5c4b\u51b7\u6696\u5b9e\u666f\u6848\u4f8b\uff1a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u5ba2\u9910\u538571+25\u53cc\u5185\u673a\u5206\u533a\u63a7\u6e29\u3001\u4e3b\u536740\u578b\u3001\u6b21\u5367\u4e0e\u4e66\u623f\u540418\u578b\uff0c\u8fde\u63a5\u7387123.75%\u5408\u89c4\u8fd0\u884c\uff1b\u535a\u4e16\u51b7\u51dd\u7089\u8282\u80fd\u8bbe\u8ba1\u5730\u6696\uff0c\u70ed\u6548\u7387\u2265105%\u3001\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u7ea620%\u3002\u7cbe\u5de5\u516b\u9636\u6bb5\u65bd\u5de5\u53ef\u89c6\u5316\u9a8c\u6536\u3001\u9690\u853d\u5de5\u7a0b\u4e09\u65b9\u76d1\u7406\u4e91\u7aef\u53ef\u67e5\uff0c\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u3001\u8d28\u4fdd\u900f\u660e\u53ef\u8ffd\u6eaf\uff0c\u4e3a\u540c\u6237\u578b\u51b7\u6696\u4e00\u4f53\u65b9\u6848\u63d0\u4f9b\u771f\u5b9e\u53c2\u8003\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=9255#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=9255"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=9255#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/gw-lcjy-cxs-fucaijinchang01.jpg","width":810,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=9255#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3","item":"https:\/\/longmai-nt.com\/?page_id=2297"},{"@type":"ListItem","position":3,"name":"\u6210\u534e\u533a\u7eff\u57ce\u9526\u56ed \u00b7 \u7a0b\u5148\u751f\u5bb6\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u535a\u4e16\u8282\u80fd\u8bbe\u8ba1\u5730\u6696"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=9255"}],"version-history":[{"count":6,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9255\/revisions"}],"predecessor-version":[{"id":16160,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9255\/revisions\/16160"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2297"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=9255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}