{"id":9303,"date":"2026-08-01T18:50:24","date_gmt":"2026-08-01T10:50:24","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=9303"},"modified":"2026-08-01T18:57:31","modified_gmt":"2026-08-01T10:57:31","slug":"%e9%ba%93%e6%b9%96%e4%ba%94%e5%bd%a9%e6%9e%97%e5%a0%a4-%e5%bc%a0%e8%80%81%e5%b8%88-%e4%ba%8c%e8%81%94%e4%be%9b%e4%ba%94%e6%81%92%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e5%af%b9%e6%af%94","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=9303","title":{"rendered":"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4"},"content":{"rendered":"\n\n<!DOCTYPE html>\n<html lang=\"zh-CN\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>\u9e93\u6e56\u4e94\u5f69\u6797\u5824\u4e8c\u8054\u4f9b\u4e94\u6052\u65b9\u6848\u5bf9\u6bd4 | \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u9e93\u6e56\u4e94\u5f69\u6797\u5824\u5f20\u8001\u5e08\u5357\u5bcc\u68ee\u8fdb\u5e97\u4e8c\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u4e94\u6052\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab+\u83f2\u65af\u66fc\u4e09\u65b9\u6848\uff0c\u542b20\u5e74\u603b\u8d26\u4e0e\u8f85\u6750\u6e05\u5355\u3002\">\n<meta name=\"geo.region\" content=\"CN-SC\">\n<meta name=\"geo.placename\" content=\"\u6210\u90fd\u5e02\">\n<meta name=\"geo.position\" content=\"30.6724;104.0668\">\n<meta name=\"ICBM\" content=\"30.6724,104.0668\">\n<meta name=\"robots\" content=\"noindex,nofollow\">\n<meta name=\"lm-case-id\" content=\"NFS-WCLD-ZLS-20260801-FA01\">\n<meta name=\"lm-doc-type\" content=\"\u65b9\u6848\u4e66 \u00b7 \u65b9\u6848\u5bf9\u6bd4\u671f Phase 1\">\n<meta name=\"lm-advisor\" content=\"\u4f59\u6653\u73b2 \u00b7 \u5357\u5bcc\u68ee\u95e8\u5e97\u9500\u552e\u987e\u95ee \u00b7 \u4ece\u4e1a22\u5e74 \u00b7 13008113409\">\n<meta property=\"og:title\" content=\"\u9e93\u6e56\u4e94\u5f69\u6797\u5824\u4e8c\u8054\u4f9b\u4e94\u6052\u65b9\u6848\u5bf9\u6bd4 | \u9f99\u8109\u6696\u901a\">\n<meta property=\"og:description\" content=\"\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u4e94\u6052 \/ \u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34 \/ \u8212\u4eab+\u83f2\u65af\u66fc \u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u542b20\u5e74\u603b\u8d26\u4e0e\u8f85\u6750\u6e05\u5355\u3002\">\n<meta property=\"og:type\" content=\"article\">\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u9e93\u6e56\u4e94\u5f69\u6797\u5824\u4e8c\u8054\u4f9b\u4e94\u6052\u65b9\u6848\u5bf9\u6bd4\u65b9\u6848\u4e66\",\n  \"identifier\": \"NFS-WCLD-ZLS-20260801-FA01\",\n  \"author\": {\"@type\": \"Person\",\"name\": \"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u9500\u552e\u987e\u95ee \u4f59\u6653\u73b2\",\"telephone\": \"13008113409\"},\n  \"publisher\": {\"@type\": \"Organization\",\"name\": \"\u9f99\u8109\u6696\u901a\"},\n  \"datePublished\": \"2026-08-01\",\n  \"about\": \"\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce \u4e8c\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\"\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\"@type\":\"Question\",\"name\":\"\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u6709\u4ec0\u4e48\u533a\u522b\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5929\u6c1f\u5730\u6c34\uff1a\u7a7a\u8c03\u4fa7\u8d70\u6c1f\uff08\u51b7\u5a92\uff09\uff0c\u4ec5\u5730\u6696\u4fa7\u8d70\u6c34\uff0c\u7cfb\u7edf\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11\uff1b\u5929\u6c34\u5730\u6c34\uff08\u6c34\u673a\uff09\uff1a\u7a7a\u8c03\u4e0e\u5730\u6696\u4e24\u4fa7\u90fd\u8d70\u6c34\uff0c\u51fa\u98ce\u66f4\u67d4\u548c\u4f46\u90e8\u4ef6\u66f4\u591a\uff08\u6c34\u6cf5\u3001\u677f\u6362\u3001\u8865\u6c34\u9600\u7b49\uff09\u3002\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\u3001\u8ffd\u6c42\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\uff0c\u5929\u6c1f\u5730\u6c34\u66f4\u5339\u914d\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e94\u6052\u7cfb\u7edf\u662f\u4e0d\u662f\u5c31\u7b49\u4e8e\u5b89\u9759\u65e0\u58f0\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6052\u9759\u4e0d\u7b49\u4e8e\u65e0\u58f0\uff0c\u662f\u63a7\u5236\u5728\u5408\u7406\u5206\u8d1d\u8303\u56f4\u5185\u3002\u4e94\u6052\u662f\u7ec4\u5408\u5f0f\u7cfb\u7edf\u2014\u2014\u4e8c\u8054\u4f9b\u7a7a\u8c03\u5730\u6696\u4e00\u4f53\uff08\u6052\u6e29\uff09\u3001\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff08\u6052\u6e7f\uff09\u3001\u5929\u51c0\u65b0\u98ce\uff08\u6052\u6c27\uff09\u3001PE\u51c0\u5316\u5185\u673a\uff08\u6052\u6d01\uff09\u3001\u4f4e\u566a\u8bbe\u5907+\u9f99\u8109\u7cbe\u5de5\u5b89\u88c5\uff08\u6052\u9759\uff09\uff0c\u7531AI\u96c6\u63a7\u7edf\u4e00\u7ba1\u7406\uff0c\u800c\u975e\u5355\u4e00\u4ea7\u54c1\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u6210\u90fd\u51ac\u5929\u96fe\u973e\u91cd\uff0c\u7a7a\u6c14\u51c0\u5316\u600e\u4e48\u89e3\u51b3\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u65b9\u6848\u4e00\/\u4e09\u91c7\u7528\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u5185\u673a\uff08\u6052\u6d01\uff09\uff0c\u65b9\u6848\u5168\u7cfb\u6807\u914d\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\uff08\u6052\u6c27+\u8fc7\u6ee4\uff09\uff0c\u7ec4\u5408\u89e3\u51b3\u96fe\u973e\u4e0e\u6362\u6c14\u9700\u6c42\uff1b\u65b0\u98ce\u4ee5\u5367\u5ba4\u98ce\u91cf\u4e3a\u4e3b\uff0c\u4fdd\u8bc1\u7761\u7720\u533a\u7a7a\u6c14\u8d28\u91cf\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u7528\u70ed\u6c34\u600e\u4e48\u4fdd\u8bc1\u7a33\u5b9a\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u70ed\u6c34\u662f\u7cfb\u7edf\u95ee\u9898\uff0c\u4e0d\u662f\u4e70\u5927\u70ed\u6c34\u5668\u5c31\u884c\uff0c\u7ba1\u8def\u8bbe\u8ba1\u624d\u662f\u5173\u952e\u3002\u9700\u7ed3\u5408\u96f6\u51b7\u6c34\u5faa\u73af\u3001\u540c\u5f00\u7387\u4e0e\u4e24\u4e2a\u536b\u751f\u95f4\u70b9\u4f4d\u505a\u7ba1\u8def\u6c34\u529b\u8bbe\u8ba1\uff0c\u65b9\u6848\u9884\u7559\u70ed\u6c34\u7cfb\u7edf\u63a5\u53e3\uff0c\u7b7e\u7ea6\u540e\u7531\u987e\u95ee\u51fa\u7ec6\u5316\u56fe\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u8d28\u4fdd\u653f\u7b56\u600e\u4e48\u6837\uff1f\u5341\u5e74\u8d28\u4fdd\u600e\u4e48\u9501\u5b9a\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5c0a\u777f\/\u6c34\u5885\u9002\/\u8212\u4eab\u8bbe\u5907\u8d28\u4fdd\u6309\u54c1\u724c\u653f\u7b56\u6267\u884c\uff08\u8be6\u89c1\u62a5\u4ef7\u8bf4\u660e\uff09\uff0c\u5730\u6696\u7531\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd\u4e09\u65b9\u8054\u4fdd50\u5e74\u3002\u54c1\u724c\u67088\u6708\u622a\u6b62\u5341\u5e74\u8d28\u4fdd\u8d44\u683c\u9501\u5b9a\uff0c\u4ea4\u5b9a\u91d1\u5373\u53ef\u9501\u5b9a\uff0c\u5efa\u8bae\u5c3d\u5feb\u786e\u8ba4\u65b9\u6848\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5730\u6696130\u33a1\u7684\u9020\u4ef7\u5305\u542b\u4ec0\u4e48\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6309\u9f99\u8109\u8282\u80fd\u5730\u6696\u7cfb\u7edf\u8ba1\u4ef7\uff08\u963b\u6c27179\u5143\/\u33a1\u4e3a\u6307\u4ee402\u4ef7\u683c\u5e93\u5957\u9910\u4ef7\uff0c\u4e0d\u6253\u6298\uff09\uff0c\u542bPE-RT\u5730\u6696\u7ba1\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u5206\u96c6\u6c34\u5668\u3001\u63a7\u5236\u7ebf\u53ca\u5305\u5de5\u5305\u6599\u5b89\u88c5\uff0c\u4e0d\u542b\u539f\u59cb\u5730\u9762\u627e\u5e73\u53ca\u9632\u6c34\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u8f85\u6750\u6e05\u5355\u91cc\u7684\u54c1\u724c\u53ef\u4ee5\u81ea\u5df1\u9009\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8f85\u6750\u4e00\u5f8b\u6309\u6307\u4ee406\u9ed8\u8ba4\u89c4\u683c\u8f93\u51fa\uff08\u5982\u94dc\u7ba1\u9f99\u715c\u3001\u4fdd\u6e29\u4f18\u83f2\u7279\u3001\u5730\u6696\u4f1f\u661f\uff09\uff0c\u54c1\u724c\u4e3a\u552f\u4e00\u5408\u6cd5\u54c1\u724c\u4e0d\u66ff\u6362\uff1b\u5982\u9500\u552e\u660e\u786e\u6307\u5b9a\u5347\u7ea7\u53ef\u9009\u8f85\u6750\uff0c\u5c06\u66ff\u6362\u5e76\u6807\u6ce8\u201c\u5ba2\u6237\u9009\u914d\u5347\u7ea7\u201d\u3002\u8f85\u6750\u6e05\u5355\u4ec5\u5217\u54c1\u724c\u89c4\u683c\uff0c\u4e0d\u542b\u4ef7\u683c\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5929\u51c0\u65b0\u98ce350\u4e00\u53f0\u80fd\u7ba1\u4e24\u5c42\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5929\u51c0\u65b0\u98ce350\u98ce\u91cf350m\u00b3\/h\uff0c\u672c\u65b9\u6848\u7528\u4e8e\u4e8c\u5c42\u5367\u5ba4\u4e3a\u4e3b\uff0c\u4fdd\u8bc1\u5367\u5ba4\u98ce\u91cf\uff1b\u4e00\u5c42\u5982\u9700\u8981\u53ef\u53e6\u505a\u98ce\u91cf\u6821\u6838\u6216\u589e\u914d\uff0c\u4ee5\u73b0\u573a\u5b9a\u4f4d\u540e\u5b9e\u9645\u4e3a\u51c6\uff0c\u62a5\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e09\u65b9\u6848\u521d\u6295\u8d44\u5dee\u5f02\u4e3b\u8981\u6765\u81ea\u54ea\u91cc\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u65b9\u6848\u4e00\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236+160\u6c34\u6a21\u5757+\u96c6\u63a7\u5c4f\u4e3a\u5168\u6548\u4e94\u6052\u65d7\u8230\u914d\u7f6e\uff0c\u521d\u6295\u6700\u9ad8106853\u5143\uff1b\u65b9\u6848\u4e8c\u6c34\u5885\u9002\u4e3b\u673a\u4e0e\u96f6\u8d8a\u98ce\u76d8\u5747\u4e3a\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\uff0c\u516d\u53f0\u98ce\u76d8\u9010\u53f0\u6838\u4ef718924\u5143\uff0c\u52a0\u6c34\u7cfb\u7edf\u5b89\u88c5\uff086\u53f0\u5185\u673a+1\u53f0\u4e3b\u673a\uff09\u00d73200\u5143\/\u53f0\u00d78\u6298\uff1d17920\u5143\uff0c\u5408\u8ba1104499\u5143\uff0c\u4e0e\u65b9\u6848\u4e00\u4ec5\u5dee2354\u5143\uff1b\u65b9\u6848\u4e09\u8212\u4eab\u4e3b\u673a8\u6298\u6700\u4fbf\u5b9c\uff0c\u52a0\u83f2\u65af\u66fc\u9505\u7089\u540e89304\u5143\u4e3a\u4e09\u65b9\u6848\u6700\u4f4e\u300220\u5e74\u603b\u8d26\u9700\u7ed3\u5408\u8fd0\u884c\u8d39\u4e0e\u7ef4\u62a4\u8d39\u7efc\u5408\u8bc4\u4f30\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u6c34\u5885\u9002\u516d\u53f0\u98ce\u76d8\u4e3a\u4ec0\u4e48\u4e0d\u80fd\u6309\u5747\u4ef7\u4f30\u7b97\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6c34\u5885\u9002\u98ce\u673a\u76d8\u7ba1\u5728\u4ef7\u683c\u5e93\u4e2d\u5206 AC\u3001\u7b80\u7ea6DC\u3001\u96f6\u8d8a \u4e09\u4e2a\u6863\u4f4d\uff0c\u540c\u89c4\u683c\u4ef7\u5dee\u6700\u9ad8\u53ef\u8fbe\u4e09\u500d\u2014\u2014\u4ee5136\u578b\u4e3a\u4f8b\uff0cAC 1835\u5143\u3001\u7b80\u7ea6DC 3951\u5143\u3001\u96f6\u8d8a 4700\u5143\u3002\u672c\u6237\u516d\u53f0\u89c4\u683c\u4ece34\u578b\u5230136\u578b\u5404\u4e0d\u76f8\u540c\uff0c\u5fc5\u987b\u9010\u53f0\u6309\u578b\u53f7\u53d6\u4ef7\uff1a4700\uff0b3136\uff0b2625\uff0b2625\uff0b3086\uff0b2752\uff1d18924\u5143\u3002\u672c\u65b9\u6848\u5df2\u5217\u51fa\u9010\u53f0\u6838\u4ef7\u660e\u7ec6\u8868\uff0c\u53ef\u5bf9\u7167\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff08page_id=662\uff09\u9644\u5f55\u4e8c\u00b72.3\u9010\u6761\u590d\u6838\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u65b9\u6848\u4e8c\u6c34\u5885\u9002\u7684\u5b89\u88c5\u8d39\u4e3a\u4ec0\u4e48\u5355\u72ec\u5217\u51fa\u6765\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6c34\u7cfb\u7edf\uff08\u5929\u6c34\u5730\u6c34\uff09\u4e3b\u673a\u4e0e\u672b\u7aef\u5747\u9700\u73b0\u573a\u6c34\u8def\u8fde\u63a5\u3001\u6c34\u538b\u8bd5\u9a8c\u4e0e\u6c34\u8d28\u5904\u7406\uff0c\u5b89\u88c5\u5de5\u7a0b\u91cf\u4e0e\u6c1f\u7cfb\u7edf\u4e0d\u540c\uff0c\u56e0\u6b64\u6309\u53f0\u6570\u5355\u72ec\u8ba1\u53d6\uff1a\uff08\u5185\u673a6\u53f0+\u4e3b\u673a1\u53f0\uff09\u00d73200\u5143\/\u53f0\u00d78\u6298=17920\u5143\u3002\u65b9\u6848\u4e00\u4e0e\u65b9\u6848\u4e09\u7684\u5185\u673a\u5b89\u88c5\u8d39\u5df2\u542b\u5728\u8bbe\u5907\u542b\u5b89\u88c5\u62a5\u4ef7\u5185\uff0c\u4e0d\u91cd\u590d\u8ba1\u53d6\uff0c\u53e3\u5f84\u4e00\u81f4\u53ef\u76f4\u63a5\u6a2a\u5411\u6bd4\u8f83\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5e38\u4f4f3\u81f34\u4eba\u5bf9\u9009\u578b\u6709\u4ec0\u4e48\u5f71\u54cd\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5e38\u4f4f3\u81f34\u4eba\u3001\u516d\u4e2a\u623f\u95f4\u5b9e\u9645\u5e38\u5f002\u81f33\u53f0\uff0c\u540c\u5f00\u7387\u7ea640%\u81f350%\uff0c\u5c5e\u4e2d\u7b49\u504f\u4f4e\u3002\u6c34\u673a\u7684\u8bbe\u8ba1\u81ea\u7531\u4f18\u52bf\u9700\u8981\u5728\u4f4e\u540c\u5f00\u7387\u4e14\u5927\u4f53\u91cf\uff08\u901a\u5e38200\u33a1\u4ee5\u4e0a\uff09\u65f6\u624d\u5212\u7b97\uff0c\u672c\u6237\u91c7\u6696130\u33a1\u672a\u5230\u4e34\u754c\u70b9\uff1b\u540c\u65f63\u81f34\u4eba\u4e24\u536b\u540c\u65f6\u7528\u70ed\u6c34\u7684\u6982\u7387\u4e0d\u4f4e\uff0c\u70ed\u6c34\u4fa7\u9700\u6309\u96f6\u51b7\u6c34\u5faa\u73af\u505a\u7ba1\u8def\u8bbe\u8ba1\uff0c\u800c\u975e\u5355\u7eaf\u653e\u5927\u70ed\u6c34\u5668\u5bb9\u91cf\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u62a5\u4ef7\u91cc\u7684\u6298\u6263\u4f9d\u636e\u662f\u4ec0\u4e48\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6298\u6263\u4e25\u683c\u6309\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff1a\u8212\u4eab8\u6298\u3001\u5c0a\u777f\u5168\u65488.5\u6298\u3001\u6c34\u5885\u9002\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\u3001\u83f2\u65af\u66fc\u4e0e\u5730\u6696\u5355\u4ef7\u4e0d\u6253\u6298\u3001160\u6c34\u6a21\u5757\u6309\u672c\u5355\u7ea6\u5b9a\u4e0d\u6253\u6298\u3001\u5929\u51c0\u65b0\u98ce\u4e0e\u96c6\u63a7\u5c4f\u6309\u9762\u4ef7\u5c0a\u777f\u7c7b8.5\u6298\u3002\u6240\u6709\u4ef7\u683c\u4e3a\u6307\u4ee402\u771f\u503c\uff0c\u672a\u5217\u4e0d\u5b9e\u62a5\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u65b9\u6848\u662f\u5426\u5305\u542b\u5e73\u9762\u56fe\u786e\u8ba4\u7684\u7cbe\u786e\u914d\u7f6e\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u672c\u65b9\u6848\u4f9d\u636e\u5df2\u63d0\u4f9b\u7684\u5efa\u7b51\u8be6\u60c5\uff08\u590d\u5f0f\u6d0b\u623f\u3001\u91c7\u6696130\u33a1\u3001\u5404\u623f\u95f4\u9762\u79ef\u4e0e\u5185\u673a\u914d\u7f6e\uff09\u751f\u6210\uff1b\u5f85\u6b63\u5f0f\u5e73\u9762\u56fe\u4e0e\u5e38\u4f4f\u4eba\u6570\/\u540c\u5f00\u7387\u786e\u8ba4\u540e\uff0c\u53ef\u5fae\u8c03\u5185\u673a\u70b9\u4f4d\u4e0e\u4e3b\u673a\u9009\u578b\uff0c\u62a5\u4ef7\u4ee5\u6700\u7ec8\u7b7e\u7ea6\u7248\u4e3a\u51c6\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5b89\u88c5\u548c\u552e\u540e\u7531\u8c01\u8d1f\u8d23\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u7531\u9f99\u8109\u6696\u901a\u81ea\u6709\u6280\u5e08\u56e2\u961f\u5b89\u88c5\uff0c\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u201c\u661f\u76d1\u7406\u201d\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f\uff1b\u5730\u6696\u4e09\u65b9\u8054\u4fdd\uff08\u9f99\u8109+\u4f1f\u661f+\u4e2d\u56fd\u4eba\u4fdd\uff09\u3002\u552e\u540e\u5b9e\u5f55\u53ef\u5728\u6848\u4f8b\u4e2d\u5fc3\u67e5\u770b\u540c\u5c0f\u533a\u53ca\u540c\u7cfb\u7edf\u5b8c\u5de5\u6848\u4f8b\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5929\u6c1f\u5730\u6c34\u65b9\u6848\u771f\u7684\u6700\u770120\u5e74\u603b\u8d26\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u662f\u7684\uff0c\u65b9\u6848\u4e00190053\u5143\u4e3a\u4e09\u65b9\u6848\u6700\u4f4e\uff1a\u6bd4\u65b9\u6848\u4e8c202099\u5143\u4f4e12046\u5143\uff0c\u6bd4\u65b9\u6848\u4e09210301\u5143\u4f4e20248\u5143\u3002\u5173\u952e\u5728\u4e8e\u4e24\u4e2a\u4e8c\u8054\u4f9b\u7684\u521d\u6295\u51e0\u4e4e\u6301\u5e73\uff08\u4ec5\u5dee2354\u5143\uff09\uff0c\u800c\u65b9\u6848\u4e00\u6bcf\u5e74\u8fd0\u884c\u8d39\u5c11220\u5143\u3001\u7ef4\u62a4\u8d39\u5c11500\u5143\uff0c\u7b2c4\u5e74\u5373\u5b8c\u6210\u53cd\u8d85\u3002\u65b9\u6848\u4e09\u5219\u76f8\u53cd\uff0c\u521d\u6295\u6700\u4f4e\u4f46\u91c7\u6696\u70e7\u6c14\u4e14\u7b2c10\u5e74\u9700\u66f4\u6362\u51b7\u51dd\u7089\uff0c\u957f\u671f\u6700\u8d35\u3002\u8fd0\u884c\u8d39\u6309\u91c7\u6696\u5b63110\u5929\u3001\u5236\u51b7\u5b6390\u5929\u3001\u65b0\u98ce\u5168\u5e74365\u5929\u6d4b\u7b97\uff0c\u660e\u7ec6\u8868\u5df2\u516c\u5f00\u5168\u90e8\u53c2\u6570\u53ef\u81ea\u884c\u9a8c\u7b97\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e3a\u4ec0\u4e48\u4e24\u4e2a\u4e8c\u8054\u4f9b\u7684\u91c7\u6696\u8d39\u5b8c\u5168\u4e00\u6837\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u56e0\u4e3a\u91c7\u6696\u4fa7\u7684\u7269\u7406\u8fc7\u7a0b\u662f\u540c\u4e00\u4ef6\u4e8b\uff1a\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09\u548c\u65b9\u6848\u4e8c\uff08\u5929\u6c34\u5730\u6c34\uff09\u90fd\u662f\u70ed\u6cf5\u4e3b\u673a\u5236\u53d635\uff5e40\u2103\u70ed\u6c34\uff0c\u518d\u9001\u8fdb130\u33a1\u5730\u6696\u76d8\u7ba1\u3002\u70ed\u6e90\u76f8\u540c\u3001\u51fa\u6c34\u6e29\u5ea6\u76f8\u540c\u3001\u5730\u6696\u6563\u70ed\u65b9\u5f0f\u76f8\u540c\uff0c\u80fd\u8017\u81ea\u7136\u76f8\u540c\u2014\u2014\u91c7\u6696\u5b63110\u5929\u5404\u7ea62570\u5143\u3002\u4e24\u8005\u7684\u5dee\u5f02\u53ea\u5728\u7a7a\u8c03\u4fa7\uff1a\u65b9\u6848\u4e00\u7a7a\u8c03\u8d70\u6c1f\uff08\u76f4\u81a8\uff09\uff0c\u65b9\u6848\u4e8c\u7a7a\u8c03\u4e5f\u8d70\u6c34\u3002\u6240\u4ee5\u4efb\u4f55\u8bf4\u5929\u6c1f\u5730\u6c34\u6bd4\u5929\u6c34\u5730\u6c34\u91c7\u6696\u66f4\u7701\u7684\u8bf4\u6cd5\u90fd\u662f\u4e0d\u6210\u7acb\u7684\uff0c\u6211\u4eec\u4e0d\u505a\u8fd9\u79cd\u8bef\u5bfc\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u65b9\u6848\u4e8c\u6c34\u5885\u9002\u4e3a\u4ec0\u4e48\u5236\u51b7\u6bd4\u53e6\u5916\u4e24\u4e2a\u65b9\u6848\u8d39\u7535\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e24\u4e2a\u539f\u56e0\u3002\u4e00\u662f\u4e8c\u6b21\u6362\u70ed\uff1a\u6c1f\u7cfb\u7edf\u51b7\u5a92\u76f4\u63a5\u5728\u5ba4\u5185\u673a\u84b8\u53d1\u6362\u70ed\uff0c\u6c34\u7cfb\u7edf\u8981\u5148\u628a\u51b7\u5a92\u7684\u51b7\u91cf\u4f20\u7ed9\u51b7\u51bb\u6c34\u3001\u518d\u7531\u51b7\u51bb\u6c34\u4f20\u7ed9\u672b\u7aef\uff0c\u591a\u4e00\u6b21\u6362\u70ed\u5c31\u591a\u4e00\u6b21\u6e29\u5dee\u635f\u5931\uff0c\u4e3b\u673a\u84b8\u53d1\u6e29\u5ea6\u5fc5\u987b\u538b\u5f97\u66f4\u4f4e\uff0c\u7efc\u5408EER\u4ece3.3\u964d\u5230\u7ea62.90\u3002\u4e8c\u662f\u6c34\u6cf5\uff1a\u5168\u6c34\u7cfb\u7edf\u9700\u8981\u5faa\u73af\u6cf5\u5e38\u5e74\u8fd0\u884c\uff0c\u6309250W\u4e588\u5c0f\u65f6\u4e5890\u5929\u8ba1\u7ea6108\u5143\u3002\u4e24\u9879\u76f8\u52a0\uff0c\u5236\u51b7\u5b63\u7ea6690\u5143\uff0c\u6bd4\u65b9\u6848\u4e00\u6c1f\u4fa7\u76f4\u81a8\u7684470\u5143\u9ad8\u7ea647%\u3002\u8fd9\u662f\u6c34\u7cfb\u7edf\u7684\u56fa\u6709\u4ee3\u4ef7\uff0c\u4e0d\u662f\u4ea7\u54c1\u597d\u574f\u95ee\u9898\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u71c3\u6c14\u51b7\u51dd\u7089\u91c7\u6696\u5230\u5e95\u6bd4\u70ed\u6cf5\u8d35\u591a\u5c11\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6309\u672c\u6237130\u33a1\u5730\u6696\u6d4b\u7b97\uff1a\u91c7\u6696\u5b63\u603b\u70ed\u9700\u6c42\u7ea612012\u5343\u74e6\u65f6\u3002\u70ed\u6cf5\u5728\u4f4e\u6e29\u5730\u6696\u5de5\u51b5COP\u53d62.8\uff0c\u8017\u75354290\u5ea6\uff0c\u63090.60\u5143\u6bcf\u5ea6\u7b972574\u5143\uff1b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u630998%\u5b63\u8282\u6548\u7387\u6298\u7b97\u8017\u6c141242\u7acb\u65b9\u7c73\uff0c\u63092.70\u5143\u6bcf\u7acb\u65b9\u7c73\u7b973353\u5143\uff0c\u53e6\u52a0\u9505\u7089\u81ea\u8eab\u5faa\u73af\u6cf5\u4e0e\u98ce\u673a\u8017\u7535\u7ea687\u5143\uff0c\u5408\u8ba13440\u5143\u3002\u6bcf\u5e74\u591a\u7ea6870\u5143\uff0c20\u5e74\u7d2f\u8ba1\u7ea617400\u5143\u3002\u800c\u4e14\u71c3\u6c14\u662f\u9636\u68af\u8ba1\u4ef7\uff0c\u7528\u91cf\u8d8a\u5927\u5355\u4ef7\u8d8a\u9ad8\uff0c\u8fd9\u4e2a\u5dee\u989d\u53ea\u4f1a\u6269\u5927\u4e0d\u4f1a\u7f29\u5c0f\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e3a\u4ec0\u4e48\u65b9\u6848\u4e09\u8981\u7b97\u4e00\u6b21\u8bbe\u5907\u66f4\u6362\uff0c\u4e24\u4e2a\u4e8c\u8054\u4f9b\u5374\u4e0d\u7528\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8fd9\u662f\u8bbe\u5907\u5bff\u547d\u7684\u5ba2\u89c2\u5dee\u5f02\u3002\u65e5\u7acb\u70ed\u6cf5\u4e3b\u673a\u630920\u5e74\u7cfb\u7edf\u5bff\u547d\u8bbe\u8ba1\uff0c20\u5e74\u5468\u671f\u5185\u4e0d\u9700\u8981\u4e8c\u6b21\u8d2d\u7f6e\uff1b\u65b9\u6848\u4e8c\u7684\u6c34\u6cf5\u3001\u677f\u6362\u5c5e\u4e8e\u53ef\u7ef4\u4fee\u66f4\u6362\u7684\u8f85\u4ef6\uff0c\u6210\u672c\u5df2\u7ecf\u644a\u8fdb\u4e86\u6bcf\u5e741100\u5143\u7684\u7ef4\u62a4\u8d39\u91cc\uff0c\u4e0d\u91cd\u590d\u8ba1\u4e3a\u66ff\u6362\u6210\u672c\u3002\u800c\u71c3\u6c14\u51b7\u51dd\u7089\u7684\u6362\u70ed\u5668\u4e0e\u71c3\u70e7\u7ec4\u4ef6\u662f\u6d88\u8017\u6027\u90e8\u4ef6\uff0c\u5bff\u547d\u901a\u5e3810\uff5e12\u5e74\uff0c20\u5e74\u5468\u671f\u5185\u5fc5\u987b\u6574\u673a\u66f4\u63621\u6b21\uff0c\u6309\u5f53\u524d\u5355\u4ef713597\u5143\u8ba1\u5165\uff08\u8fd8\u6ca1\u7b97\u901a\u80c0\uff0c\u5b9e\u9645\u66f4\u6362\u65f6\u5927\u6982\u7387\u66f4\u8d35\uff09\u3002\u8fd9\u4e00\u7b14\u6b63\u597d\u5728\u7b2c10\u5e74\u53d1\u751f\uff0c\u4e5f\u6b63\u662f\u65b9\u6848\u4e09\u603b\u8d26\u88ab\u53cd\u8d85\u7684\u65f6\u70b9\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e3a\u4ec0\u4e48\u987e\u95ee\u503e\u5411\u5929\u6c1f\u5730\u6c34\u800c\u4e0d\u662f\u76f4\u63a5\u63a8\u6c34\u673a\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u590d\u5f0f\u6d0b\u623f\u91c7\u6696130\u33a1\u3001\u5e38\u4f4f3\u81f34\u4eba\u3001\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\uff08\u4e00\u697c\u5ba2\u9910\u5385\u52a0\u4e8c\u697c\u4e3b\u5367\uff09\u3001\u5ba2\u6237\u8ffd\u6c42\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\uff0c\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u7b80\u6d01\u6545\u969c\u70b9\u5c11\u66f4\u5339\u914d\uff1b\u6c34\u673a\u7684\u8bbe\u8ba1\u81ea\u7531\u3001\u51fa\u98ce\u67d4\u548c\u4f18\u52bf\u4e3b\u8981\u5728\u4f4e\u540c\u5f00\u7387\u5927\u6237\u578b\u624d\u663e\u73b0\u3002\u6211\u4eec\u505a\u4e13\u4e1a\u5bf9\u6bd4\u4e0d\u56de\u907f\u52a3\u52bf\uff0c\u5e2e\u5ba2\u6237\u9009\u6700\u9002\u5408\u7684\u800c\u975e\u6700\u8d35\u7684\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u9f99\u8109\u6696\u901a\u6709\u54ea\u4e9b\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u8d44\u8d28\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u9f99\u8109\u6696\u901a\u6301\u6709\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09\u3001\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\uff082026\uff09\u3001\u7279\u7ea6\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09\u3001\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u5546\u4e13\u9879\u6388\u6743\u3001\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082024\uff09\u5171\u4e94\u9879\u8d44\u8d28\uff0c\u65b9\u6848\u4e66\u9644\u5f55\u5185\u4e3a\u8bc1\u4e66\u5b9e\u62cd\u3002\u6388\u6743\u51b3\u5b9a\u80fd\u5426\u4eab\u53d7\u539f\u5382\u5b89\u88c5\u6807\u51c6\u3001\u539f\u5382\u914d\u4ef6\u4e0e\u6574\u673a\u8d28\u4fdd\u653f\u7b56\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u65b9\u6848\u4e66\u91cc\u7684\u56fe\u7247\u4f1a\u88c2\u56fe\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4ea7\u54c1\u56fe\u4e0e\u95e8\u5e97\u5b9e\u666f\u5747\u53d6\u81ea\u9f99\u8109\u5b98\u7f51\u5a92\u4f53\u5e93\u6b63\u5f0f\u5730\u5740\uff0c\u6388\u6743\u8bc1\u4e66\u4e3a\u5b9e\u62cd\u539f\u56fe\uff1b\u53d1\u5e03\u81f3\u5b98\u7f51\u65f6\u56fe\u7247URL\u6309\u89c4\u5219\u5904\u7406\u907f\u514d\u4e8c\u6b21\u8ffd\u52a0\u540e\u7f00\uff0c\u786e\u4fdd\u4e0d\u88c2\u56fe\u3002\"}}\n  ]\n}\n<\/script>\n<style>\n:root{\n  --gold:#c89b3c; --gold-d:#9a7414; --navy:#1a3a5c; --navy-d:#102740;\n  --ink:#2a2f36; --muted:#6b7480; --line:#e6e9ee; --bg:#ffffff; --bg2:#f7f9fb;\n  --ok:#2e8b6b; --warn:#c0792b; --soft:#eef3f8;\n}\n*{box-sizing:border-box;margin:0;padding:0}\nbody{font-family:\"PingFang SC\",\"Microsoft YaHei\",-apple-system,system-ui,sans-serif;color:var(--ink);background:var(--bg);line-height:1.7;font-size:16px}\n.wrap{max-width:1080px;margin:0 auto;padding:0 20px}\na{color:var(--navy);text-decoration:none}\nimg{max-width:100%;display:block}\n\n\/* HERO *\/\n.hero{position:relative;color:#fff;padding:96px 0 84px;\n  background:linear-gradient(120deg,rgba(11,31,51,.90) 0%,rgba(11,31,51,.74) 46%,rgba(26,58,92,.58) 100%),\n  url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-yxl-rlzrqx-sjrssxjn.jpg') center 38%\/cover no-repeat;\n  background-attachment:scroll}\n.hero::after{content:\"\";position:absolute;left:0;right:0;bottom:0;height:120px;background:linear-gradient(180deg,transparent,rgba(11,31,51,.55))}\n.hero .wrap{position:relative;z-index:2}\n.hero .tag{display:inline-block;border:1px solid var(--gold);background:rgba(11,31,51,.45);color:var(--gold);padding:5px 16px;border-radius:20px;font-size:13px;letter-spacing:1px;margin-bottom:18px}\n.hero h1{font-size:38px;line-height:1.28;margin-bottom:14px;font-weight:800;text-shadow:0 2px 18px rgba(0,0,0,.45)}\n.hero p{color:#e2e9f2;font-size:16px;max-width:720px;text-shadow:0 1px 10px rgba(0,0,0,.5)}\n.hero .meta{margin-top:28px;display:flex;flex-wrap:wrap;gap:10px}\n.hero .meta span{background:rgba(8,22,38,.52);backdrop-filter:blur(4px);border:1px solid rgba(200,163,90,.45);padding:7px 15px;border-radius:8px;font-size:14px;color:#eef3f9}\n.hero .meta b{color:var(--gold)}\n.hero .hcta{margin-top:26px;display:flex;gap:12px;flex-wrap:wrap;align-items:center}\n.hero .hcta a{background:var(--gold);color:var(--navy-d);padding:12px 24px;border-radius:10px;font-weight:800;font-size:15px;box-shadow:0 6px 20px rgba(200,163,90,.28);transition:.2s}\n.hero .hcta a:hover{background:#dcb96f;transform:translateY(-1px)}\n.hero .hcta a.hghost{background:rgba(8,22,38,.42);border:1px solid var(--gold);color:var(--gold);box-shadow:none}\n.hero .hcta a.hghost:hover{background:rgba(200,163,90,.18)}\n.hero .hcta .hnote{font-size:13px;color:#cfdae7}\n\n\/* \u60ac\u6d6e\u5bfc\u822a\u680f *\/\n.nav{position:sticky;top:0;z-index:60;background:rgba(255,255,255,.82);backdrop-filter:saturate(160%) blur(14px);border-bottom:1px solid rgba(224,230,237,.9);transition:box-shadow .25s,background .25s}\n.nav.stuck{box-shadow:0 6px 24px rgba(11,31,51,.13);background:rgba(255,255,255,.95)}\n.nav .wrap{display:flex;gap:4px;padding:10px 20px;align-items:center;overflow-x:auto;scrollbar-width:none}\n.nav .wrap::-webkit-scrollbar{display:none}\n.nav .brand{font-weight:800;color:var(--navy-d);font-size:15px;margin-right:10px;white-space:nowrap;flex:0 0 auto;border-right:1px solid var(--line);padding-right:12px}\n.nav a{font-size:14px;padding:7px 13px;border-radius:20px;color:var(--navy);font-weight:600;white-space:nowrap;flex:0 0 auto;transition:.2s}\n.nav a:hover{background:var(--soft)}\n.nav a.on{background:var(--navy);color:#fff}\n.nav .navtel{margin-left:auto;flex:0 0 auto;background:var(--gold);color:#fff;padding:7px 16px;border-radius:20px;font-weight:800}\n.nav .navtel:hover{background:var(--gold-d);color:#fff}\n@media(max-width:860px){.nav .navtel{display:none}}\n\/* \u60ac\u6d6e\u5bfc\u822a\uff1a\u5b50\u76ee\u5f55\u4e0b\u62c9\u9762\u677f\uff08\u72ec\u7acb\u4e8e\u6a2a\u5411\u6eda\u52a8\u6761\uff0c\u907f\u514d\u88ab\u88c1\u5207\uff09 *\/\n.nav .menu{flex:0 0 auto;display:inline-flex}\n.nav .menu-trigger{cursor:pointer}\n.nav .sub{position:absolute;top:calc(100% + 6px);left:auto;min-width:172px;\n  background:#fff;border:1px solid var(--line);border-radius:12px;\n  box-shadow:0 14px 36px rgba(11,31,51,.18);padding:6px;\n  display:flex;flex-direction:column;gap:3px;\n  opacity:0;visibility:hidden;transform:translateY(-6px);transition:.18s;z-index:75}\n.nav.sub-open .sub{opacity:1;visibility:visible;transform:translateY(0)}\n.nav .sub a{padding:10px 14px;border-radius:8px;font-size:14px;color:var(--navy);font-weight:600;white-space:nowrap}\n.nav .sub a:hover{background:var(--soft)}\n.nav .sub a.on{background:var(--navy);color:#fff}\n\n\/* SECTION *\/\nhtml{scroll-behavior:smooth}\nsection{padding:54px 0;border-bottom:1px solid var(--line);scroll-margin-top:64px}\n.sec-h{display:flex;align-items:center;gap:14px;margin-bottom:8px}\n.sec-n{background:var(--navy);color:#fff;width:38px;height:38px;border-radius:10px;display:flex;align-items:center;justify-content:center;font-weight:800;font-size:18px;flex:0 0 auto}\n.sec-h h2{font-size:25px;color:var(--navy-d);font-weight:800}\n.sec-sub{color:var(--muted);margin-bottom:26px;font-size:15px}\n\n\/* CARDS *\/\n.grid{display:grid;gap:16px}\n.g3{grid-template-columns:repeat(3,1fr)}\n.g2{grid-template-columns:repeat(2,1fr)}\n.card{background:var(--bg2);border:1px solid var(--line);border-radius:14px;padding:20px}\n.card h3{font-size:17px;color:var(--navy-d);margin-bottom:8px}\n.card p{font-size:14px;color:var(--muted)}\n.kpi{font-size:26px;font-weight:800;color:var(--gold-d)}\n\n\/* \u5ba2\u6237\u753b\u50cf *\/\n.profile{display:grid;grid-template-columns:1.3fr 1fr;gap:20px}\n.pbox{background:linear-gradient(135deg,#fff,#f3f7fb);border:1px solid var(--line);border-radius:14px;padding:22px}\n.pbox h3{color:var(--navy-d);margin-bottom:14px;font-size:18px}\n.kv{display:flex;justify-content:space-between;padding:8px 0;border-bottom:1px dashed var(--line);font-size:14px}\n.kv:last-child{border-bottom:none}\n.kv b{color:var(--navy)}\n.stars{color:var(--gold);letter-spacing:2px}\n.weights li{list-style:none;display:flex;align-items:center;justify-content:space-between;padding:10px 0;border-bottom:1px solid var(--line)}\n.weights li:last-child{border-bottom:none}\n.weights .wname{font-weight:600}\n.weights .wbar{flex:1;height:8px;background:var(--line);border-radius:6px;margin:0 14px;overflow:hidden}\n.weights .wbar i{display:block;height:100%;background:linear-gradient(90deg,var(--gold),var(--gold-d))}\n\n\/* TABS *\/\n.tabs{display:flex;gap:8px;margin-bottom:18px;flex-wrap:wrap}\n.tab{padding:9px 18px;border:1px solid var(--line);border-radius:10px;cursor:pointer;font-weight:600;font-size:15px;background:#fff;color:var(--navy)}\n.tab.active{background:var(--navy);color:#fff;border-color:var(--navy)}\n.tabpane{display:none}\n.tabpane.active{display:block}\n.tabpane .card{background:#fff}\n\n\/* \u5bf9\u6bd4\u8868 *\/\n.tbl{width:100%;border-collapse:collapse;font-size:14px;margin-top:6px}\n.tbl th,.tbl td{border:1px solid var(--line);padding:11px 12px;text-align:left;vertical-align:top}\n.tbl thead th{background:var(--navy);color:#fff;font-weight:700}\n.tbl tbody tr:nth-child(even){background:var(--bg2)}\n.tbl .pl{font-weight:700;color:var(--navy-d)}\n.tbl .hi{color:var(--ok);font-weight:700}\n.tbl .mid{color:var(--warn);font-weight:700}\n\n\/* \u4ea7\u54c1\u7ffb\u8f6c\u5361 *\/\n.flip{display:grid;grid-template-columns:repeat(3,1fr);gap:16px}\n.fcard{perspective:1200px;border-radius:14px}\n.fcard .inner{position:relative;transition:transform .65s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d;min-height:330px}\n.fcard:hover .inner,.fcard:focus-within .inner{transform:rotateY(180deg)}\n.fcard .face{position:absolute;inset:0;backface-visibility:hidden;-webkit-backface-visibility:hidden;border-radius:14px;border:1px solid var(--line);display:flex;flex-direction:column;overflow:hidden}\n.fcard .front{background:linear-gradient(160deg,#fff,#eef3f8)}\n.fcard .front .pimg{width:100%;height:200px;overflow:hidden;background:#eef3f8;flex:0 0 auto}\n.fcard .front .pimg img{width:100%;height:100%;object-fit:cover;object-position:center;transition:transform .6s}\n.fcard:hover .front .pimg img{transform:scale(1.04)}\n.fcard .front .pt{padding:16px 18px;text-align:center}\n.fcard .front h4{font-size:17px;color:var(--navy-d);font-weight:800}\n.fcard .front .sub{font-size:13px;color:var(--muted);margin-top:5px}\n.fcard .front .badge{display:inline-block;margin-top:9px;font-size:12px;color:var(--gold-d);border:1px solid var(--gold);border-radius:14px;padding:2px 12px}\n.fcard .back{background:linear-gradient(150deg,var(--navy-d),var(--navy));color:#eaf0f7;transform:rotateY(180deg);padding:20px}\n.fcard .back h4{color:var(--gold);font-size:15px;margin-bottom:10px}\n.fcard .back ul{list-style:none;font-size:13.5px}\n.fcard .back li{padding:6px 0;border-bottom:1px solid rgba(255,255,255,.12)}\n.fcard .back li:last-child{border-bottom:none}\n.fcard .back .flink{margin-top:auto;padding-top:10px;font-size:12.5px;color:var(--gold)}\n.fhint{font-size:12.5px;color:var(--muted);margin-bottom:12px}\n\n\/* \u516d\u7ef4\u5ea6\u7ffb\u8f6c\u5361 *\/\n.dflip{display:grid;grid-template-columns:repeat(3,1fr);gap:14px}\n.dcard{perspective:1200px}\n.dcard .inner{position:relative;transition:transform .6s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d;min-height:340px}\n.dcard:hover .inner,.dcard:focus-within .inner{transform:rotateY(180deg)}\n.dcard .face{position:absolute;inset:0;backface-visibility:hidden;-webkit-backface-visibility:hidden;border-radius:14px;border:1px solid var(--line);padding:18px;display:flex;flex-direction:column;overflow:auto}\n.dcard .df{background:linear-gradient(160deg,#fff,#f1f5f9)}\n.dcard .df .dno{width:30px;height:30px;border-radius:9px;background:var(--navy);color:#fff;display:flex;align-items:center;justify-content:center;font-weight:800;font-size:14px;margin-bottom:10px}\n.dcard .df h4{color:var(--navy-d);font-size:17px;margin-bottom:10px}\n.dcard .df .dr{display:flex;justify-content:space-between;font-size:13px;padding:5px 0;border-bottom:1px dashed var(--line)}\n.dcard .df .dr:last-child{border-bottom:none}\n.dcard .df .dr b{color:var(--navy-d)}\n.dcard .df .dr.win b{color:var(--ok)}\n.dcard .df .dr.bad b{color:var(--warn)}\n.dcard .db{background:linear-gradient(150deg,var(--navy-d),#16324f);color:#e6edf5;transform:rotateY(180deg)}\n.dcard .db h4{color:var(--gold);font-size:14px;margin-bottom:9px}\n.dcard .db p{font-size:13px;color:#d5e0ec;line-height:1.65}\n.dcard .db .dw{margin-top:auto;padding-top:10px;font-size:12.5px;color:var(--gold);border-top:1px solid rgba(255,255,255,.14)}\n\n\/* \u54c1\u724c\u6388\u6743 *\/\n.certs{display:grid;grid-template-columns:repeat(3,1fr);gap:16px}\n.cert{border:1px solid var(--line);border-radius:14px;overflow:hidden;background:#fff}\n.cert img{width:100%;height:250px;object-fit:contain;background:#f4f7fa;padding:8px}\n.cert .cl{padding:12px 14px;font-size:13.5px;color:var(--navy-d);font-weight:700;text-align:center;border-top:1px solid var(--line)}\n.cert .cl small{display:block;font-weight:400;color:var(--muted);font-size:12px;margin-top:3px}\n\n\/* \u62a5\u4ef7 *\/\n.quote{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-bottom:24px}\n.qcard{border:1px solid var(--line);border-radius:16px;overflow:hidden;display:flex;flex-direction:column}\n.qcard .qh{padding:18px;color:#fff;text-align:center}\n.qcard.q1 .qh{background:linear-gradient(135deg,var(--navy),#2e5f87)}\n.qcard.q2 .qh{background:linear-gradient(135deg,#3a6b4f,#5a9e72)}\n.qcard.q3 .qh{background:linear-gradient(135deg,#7a5a2e,#b08a45)}\n.qcard .qh h3{font-size:18px;margin-bottom:4px}\n.qcard .qh .price{font-size:30px;font-weight:800;margin-top:6px}\n.qcard .qh .price small{font-size:13px;font-weight:400;opacity:.85}\n.qcard .qb{padding:16px 18px;flex:1}\n.qrow{display:flex;justify-content:space-between;padding:7px 0;border-bottom:1px dashed var(--line);font-size:13.5px}\n.qrow:last-child{border-bottom:none}\n.qrow b{color:var(--navy-d)}\n.qcard .rec{background:var(--gold);color:#fff;text-align:center;padding:9px;font-weight:700;font-size:14px}\n\n\/* 20\u5e74\u603b\u8d26 \u00b7 \u6574\u5361\u7ffb\u8f6c\uff08\u6b63\uff1a\u5806\u53e0\u67f1\u56fe \/ \u53cd\uff1a\u516c\u5f0f\u660e\u7ec6\uff09 *\/\n.lwrap{perspective:1600px}\n.lwrap .linner{position:relative;transition:transform .7s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d;min-height:510px}\n.lwrap.flipped .linner{transform:rotateY(180deg)}\n.lwrap .lface{position:absolute;inset:0;backface-visibility:hidden;-webkit-backface-visibility:hidden;border:1px solid var(--line);border-radius:16px;padding:20px 20px 16px;display:flex;flex-direction:column}\n.lwrap .lfront{background:linear-gradient(160deg,#fff,#f2f6fa)}\n.lwrap .lback{background:linear-gradient(150deg,var(--navy-d),var(--navy));color:#e8eef6;transform:rotateY(180deg);overflow:auto}\n.lwrap .lhead{display:flex;justify-content:space-between;align-items:center;gap:12px;flex-wrap:wrap;margin-bottom:6px}\n.lwrap .lhead h4{color:var(--navy-d);font-size:17px}\n.lwrap .lback .lhead h4{color:var(--gold)}\n.lflipbtn{cursor:pointer;border:1px solid var(--gold);background:transparent;color:var(--gold-d);font-family:inherit;font-size:13px;font-weight:700;padding:6px 15px;border-radius:20px;transition:.2s}\n.lflipbtn:hover{background:var(--gold);color:#fff}\n.lwrap .lback .lflipbtn{color:var(--gold)}\n.lwrap .lback .lflipbtn:hover{background:var(--gold);color:var(--navy-d)}\n.lm-chart{width:100%;flex:1;min-height:360px;display:none}\n.lmfb{flex:1;display:flex;flex-direction:column;justify-content:flex-end;gap:14px;padding:14px 4px 6px}\n.lmfb .fbrow{display:grid;grid-template-columns:150px 1fr 92px;align-items:center;gap:10px;font-size:13px}\n.lmfb .fbname{color:var(--navy-d);font-weight:700;line-height:1.35}\n.lmfb .fbbar{display:flex;height:24px;border-radius:6px;overflow:hidden;background:#e8edf3}\n.lmfb .fbbar i{display:block;height:100%;flex:0 0 auto}\n.lmfb .fbbar .c0{background:#102740}\n.lmfb .fbbar .r{background:#2e5f87}\n.lmfb .fbbar .m{background:#c8a35a}\n.lmfb .fbbar .x{background:#c0792b}\n.lmfb .fbtot{text-align:right;font-weight:800;color:var(--gold-d)}\n.lmfb .fblg{display:flex;gap:16px;flex-wrap:wrap;font-size:12px;color:var(--muted);margin-top:4px}\n.lmfb .fblg em{display:inline-block;width:11px;height:9px;border-radius:2px;margin-right:5px;vertical-align:middle}\n.life{display:grid;grid-template-columns:repeat(3,1fr);gap:14px}\n.lcard{border:1px solid rgba(255,255,255,.16);border-radius:14px;padding:16px;background:rgba(255,255,255,.06)}\n.lcard h4{color:var(--gold);margin-bottom:6px;font-size:15px}\n.lcard .total{font-size:23px;font-weight:800;color:#fff;margin:6px 0}\n.formula{font-size:12.5px;color:#cfdae7;background:rgba(0,0,0,.18);border:1px dashed rgba(255,255,255,.22);border-radius:8px;padding:10px;font-family:ui-monospace,monospace;line-height:1.9}\n\n\/* \u516d\u7ef4\u6b63\u9762\u53ef\u89c6\u5316\u5bf9\u6bd4\u67f1 *\/\n.dbars{margin-top:2px}\n.dbrow{margin:9px 0}\n.dbtop{display:flex;justify-content:space-between;font-size:12.5px;color:var(--muted);margin-bottom:4px}\n.dbtop b{color:var(--navy-d);font-size:13px}\n.dbtrack{height:9px;background:#e8edf3;border-radius:6px;overflow:hidden}\n.dbfill{display:block;height:100%;border-radius:6px;background:linear-gradient(90deg,#41618a,var(--navy))}\n.dbrow.win .dbfill{background:linear-gradient(90deg,#4bb391,var(--ok))}\n.dbrow.win .dbtop b{color:var(--ok)}\n.dbrow.bad .dbfill{background:linear-gradient(90deg,#dda85e,var(--warn))}\n.dbrow.bad .dbtop b{color:var(--warn)}\n.dlegend{font-size:12px;color:var(--muted);margin-top:auto;padding-top:9px;border-top:1px dashed var(--line)}\n\n\/* \u65b9\u6848\u52a3\u52bf\u8bda\u5b9e\u62ab\u9732 *\/\n.cons{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:6px}\n.concard{border:1px solid var(--line);border-top:3px solid var(--warn);border-radius:14px;padding:18px;background:#fff}\n.concard h4{color:var(--navy-d);font-size:16px;margin-bottom:10px}\n.concard ul{list-style:none;font-size:13.5px;color:var(--ink)}\n.concard li{padding:7px 0 7px 18px;position:relative;border-bottom:1px dashed var(--line)}\n.concard li:last-child{border-bottom:none}\n.concard li::before{content:\"\u00b7\";position:absolute;left:4px;color:var(--warn);font-weight:800;font-size:18px;line-height:1.2}\n\n\/* GEO \u4fe1\u606f\u5361\uff08\u6574\u5361\u7ffb\u8f6c\uff09 *\/\n.geosec{background:var(--bg2);padding:34px 0}\n.geocard{perspective:1600px;cursor:pointer}\n.geocard .ginner{position:relative;transition:transform .7s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d;min-height:380px}\n.geocard:hover .ginner,.geocard:focus-within .ginner,.geocard.flipped .ginner{transform:rotateY(180deg)}\n.geocard .gface{position:absolute;inset:0;backface-visibility:hidden;-webkit-backface-visibility:hidden;border-radius:16px;padding:24px 26px;border:1px solid var(--line);display:flex;flex-direction:column;overflow:auto}\n.geocard .gfront{background:linear-gradient(150deg,#fff,#eef3f8)}\n.geocard .gback{background:linear-gradient(150deg,var(--navy-d),var(--navy));color:#e8eef6;transform:rotateY(180deg)}\n.geocard .gtitle{display:flex;align-items:center;gap:12px;margin-bottom:6px;flex-wrap:wrap}\n.geocard .gtitle h3{font-size:19px;color:var(--navy-d)}\n.geocard .gback .gtitle h3{color:var(--gold)}\n.geocard .gid{font-size:12px;font-family:ui-monospace,monospace;color:var(--gold-d);border:1px solid var(--gold);border-radius:14px;padding:2px 11px}\n.geocard .gback .gid{color:var(--gold);border-color:rgba(200,163,90,.6)}\n.geocard .gsum{font-size:14.5px;color:var(--ink);margin-bottom:14px}\n.geocard .gback .gsum{color:#cfdae7}\n.ggrid{display:grid;grid-template-columns:repeat(4,1fr);gap:10px}\n.ggrid div{background:#fff;border:1px solid var(--line);border-radius:10px;padding:10px 12px}\n.ggrid span{display:block;font-size:11.5px;color:var(--muted);margin-bottom:3px}\n.ggrid b{font-size:13.5px;color:var(--navy-d)}\n.gback .glist{list-style:none;font-size:13.5px}\n.gback .glist li{padding:6px 0;border-bottom:1px solid rgba(255,255,255,.12)}\n.gback .glist li:last-child{border-bottom:none}\n.gback .glist b{color:var(--gold)}\n.ghint{margin-top:auto;padding-top:10px;font-size:12px;color:var(--muted)}\n.gback .ghint{color:rgba(232,238,246,.65)}\n\n\/* \u53cc\u5411\u5185\u94fe\u7ed1\u5b9a *\/\n.backlink{margin-top:18px;background:#fff;border:1px solid var(--line);border-left:3px solid var(--gold);border-radius:10px;padding:14px 16px;font-size:13.5px;color:var(--muted)}\n.backlink b{color:var(--navy-d)}\n.backlink a{color:var(--gold-d);font-weight:700;text-decoration:underline}\n\n\/* FAQ *\/\n.faq details{border:1px solid var(--line);border-radius:12px;padding:4px 18px;margin-bottom:12px;background:#fff}\n.faq summary{cursor:pointer;font-weight:700;color:var(--navy-d);padding:14px 0;list-style:none;position:relative}\n.faq summary::-webkit-details-marker{display:none}\n.faq summary::after{content:\"+\";position:absolute;right:0;color:var(--gold);font-size:22px;font-weight:700}\n.faq details[open] summary::after{content:\"\u2212\"}\n.faq .ans{padding:0 0 16px;color:var(--muted);font-size:14.5px}\n\n\/* \u4e86\u89e3\u66f4\u591a *\/\n.more{display:grid;grid-template-columns:repeat(4,1fr);gap:14px}\n.more a{display:block;background:var(--bg2);border:1px solid var(--line);border-radius:12px;padding:18px;text-align:center;color:var(--navy-d);font-weight:700}\n.more a:hover{border-color:var(--gold);background:#fff}\n.more a small{display:block;color:var(--muted);font-weight:400;font-size:12px;margin-top:6px}\n\n\/* \u95e8\u5e97 *\/\n.stores{display:grid;grid-template-columns:1fr 1fr;gap:18px}\n.store{border:1px solid var(--line);border-radius:14px;overflow:hidden;background:#fff;transition:.25s}\n.store:hover{border-color:var(--gold);box-shadow:0 8px 26px rgba(11,31,51,.10)}\n.store img{width:100%;height:240px;object-fit:cover}\n.store .si{padding:18px}\n.store .si h4{color:var(--navy-d);font-size:18px}\n.store .si .tel{display:inline-block;color:#fff;background:var(--gold);font-weight:800;font-size:19px;margin-top:10px;padding:7px 18px;border-radius:9px;letter-spacing:.5px}\n.store .si .tel:hover{background:var(--gold-d)}\n.store .si p{font-size:13px;color:var(--muted);margin-top:10px}\n.store .si .addr{font-size:13px;color:var(--ink);margin-top:8px;padding-top:8px;border-top:1px dashed var(--line)}\n.svc{margin-top:18px;background:#fff;border:1px solid var(--line);border-left:3px solid var(--gold);border-radius:10px;padding:14px 16px;font-size:13.5px;color:var(--muted)}\n.svc b{color:var(--navy-d)}\n\n\/* CTA *\/\n.cta{background:linear-gradient(135deg,var(--navy-d),var(--navy));color:#fff;border-radius:16px;padding:30px;text-align:center;margin-top:8px}\n.cta h3{font-size:22px;margin-bottom:10px}\n.cta p{color:#cdd6e2;margin-bottom:16px}\n.cta .btns{display:flex;gap:14px;justify-content:center;flex-wrap:wrap}\n.cta a{background:var(--gold);color:var(--navy-d);padding:12px 26px;border-radius:10px;font-weight:800}\n.cta a.ghost{background:transparent;border:1px solid var(--gold);color:var(--gold)}\n\n\/* \u8f85\u6750 *\/\n.appendix{background:var(--bg2)}\n.annex{margin-bottom:18px;border:1px solid var(--line);border-radius:12px;overflow:hidden}\n.annex summary{cursor:pointer;background:var(--navy);color:#fff;padding:14px 18px;font-weight:700;list-style:none}\n.annex summary::-webkit-details-marker{display:none}\n.annex .acont{padding:18px;background:#fff}\n.annex h4{color:var(--navy-d);margin:14px 0 6px;font-size:16px}\n.note{font-size:12.5px;color:var(--muted);margin-top:10px;padding:10px;background:var(--soft);border-radius:8px;border-left:3px solid var(--gold)}\n.clause{font-size:13px;color:var(--ink);padding:5px 0 5px 22px;position:relative}\n.clause::before{content:\"1\u3001\";position:absolute;left:0;color:var(--gold-d);font-weight:700}\n\nfooter{padding:34px 0;color:var(--muted);font-size:13px;text-align:center;background:var(--bg2)}\n\n@media(max-width:960px){\n  .certs,.dflip,.cons{grid-template-columns:repeat(2,1fr)}\n  .ggrid{grid-template-columns:repeat(2,1fr)}\n  .geocard .ginner{min-height:480px}\n  .lwrap .linner{min-height:900px}\n  .life{grid-template-columns:1fr}\n  .lmfb .fbrow{grid-template-columns:120px 1fr 78px}\n}\n@media(max-width:860px){\n  .g3,.g2,.flip,.quote,.life,.more,.stores,.profile,.certs,.dflip,.cons{grid-template-columns:1fr}\n  .hero{padding:64px 0 54px}\n  .hero h1{font-size:26px}\n  .more{grid-template-columns:repeat(2,1fr)}\n  .ggrid{grid-template-columns:1fr}\n  .fcard .inner{min-height:300px}\n  .dcard .inner{min-height:290px}\n  .geocard .ginner{min-height:760px}\n  .lwrap .linner{min-height:900px}\n  .lm-chart{min-height:320px}\n  .lmfb .fbrow{grid-template-columns:96px 1fr 66px;font-size:12px}\n}\n<\/style>\n<\/head>\n<body>\n\n<!-- HERO -->\n<header class=\"hero\">\n  <div class=\"wrap\">\n    <span class=\"tag\">\u65b9\u6848\u5bf9\u6bd4\u671f \u00b7 Phase 1<\/span>\n    <h1>\u9e93\u6e56\u4e94\u5f69\u6797\u5824 \u00b7 \u4e8c\u8054\u4f9b\u4e94\u6052\u6210\u7acb\u65b9\u6848\u5bf9\u6bd4<\/h1>\n    <p>\u5f20\u8001\u5e08\uff0c\u60a8\u505a\u4e86\u529f\u8bfe\u624d\u6765\u2014\u2014\u7f51\u4e0a\u6bd4\u5b8c\u4e00\u8f6e\u65e5\u7acb\u5546\u5bb6\u4e3b\u52a8\u5230\u5e97\u3002\u6211\u4eec\u4e0d\u6bd4\u8c01\u4fbf\u5b9c\uff0c\u6bd4\u8c01\u65b9\u6848\u66f4\u4e13\u4e1a\u3001\u8c0120\u5e74\u603b\u8d26\u66f4\u7701\u3001\u8c01\u670d\u52a1\u66f4\u900f\u660e\u3002<\/p>\n    <div class=\"meta\">\n      <span>\u65b9\u6848\u7f16\u53f7 <b>NFS-WCLD-ZLS-20260801-FA01<\/b><\/span>\n      <span>\u5ba2\u6237 <b>\u5f20\u8001\u5e08<\/b><\/span>\n      <span>\u5c0f\u533a <b>\u9e93\u6e56\u4e94\u5f69\u6797\u5824<\/b><\/span>\n      <span>\u6237\u578b <b>\u590d\u5f0f\u6d0b\u623f \u00b7 \u91c7\u6696130\u33a1<\/b><\/span>\n      <span>\u5e38\u4f4f <b>3\uff5e4\u4eba<\/b><\/span>\n      <span>\u6e20\u9053 <b>\u5357\u5bcc\u68ee\u8fdb\u5e97<\/b><\/span>\n      <span>\u5bf9\u63a5\u987e\u95ee <b>\u4f59\u6653\u73b2\uff08\u9500\u552e\u987e\u95ee \u00b7 \u4ece\u4e1a22\u5e74\uff09<\/b><\/span>\n      <span>\u7cfb\u7edf <b>\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce<\/b><\/span>\n    <\/div>\n    <div class=\"hcta\">\n      <a href=\"tel:02886131795\">\u514d\u8d39\u52d8\u6d4b\u9884\u7ea6 \u00b7 028-86131795<\/a>\n      <a class=\"hghost\" href=\"#s4\">\u76f4\u63a5\u770b\u4e09\u65b9\u6848\u62a5\u4ef7<\/a>\n      <a class=\"hghost\" href=\"tel:13008113409\">\u9500\u552e\u987e\u95ee\u4f59\u6653\u73b2 13008113409<\/a>\n      <span class=\"hnote\">\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u65b9\u6848\u6df1\u5316\u4e0d\u6536\u8d39\uff0c\u52d8\u6d4b\u540e\u53ef\u9501\u5b9a\u5341\u5e74\u8d28\u4fdd\u8d44\u683c<\/span>\n    <\/div>\n  <\/div>\n<\/header>\n\n<!-- \u60ac\u6d6e\u5bfc\u822a\u680f\uff1a\u4e3b\u76ee\u5f55=\u5ba2\u6237\u6210\u529f5\u6b65 \/ \u5176\u4f59\u5f52\u5165\"\u66f4\u591a\"\u5b50\u76ee\u5f55 -->\n<nav class=\"nav\" id=\"topnav\"><div class=\"wrap\">\n  <span class=\"brand\">\u9f99\u8109\u6696\u901a<\/span>\n  <a href=\"#s1\">\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/a>\n  <a href=\"#s2\">\u65b9\u6848\u8bca\u65ad<\/a>\n  <a href=\"#s3\">\u7cfb\u7edf\u8bbe\u8ba1<\/a>\n  <a href=\"#s4\">\u900f\u660e\u62a5\u4ef7<\/a>\n  <a href=\"#s5\">\u6848\u4f8b\u9a8c\u8bc1<\/a>\n  <span class=\"menu\"><a class=\"menu-trigger\" id=\"menutrigger\" href=\"#faq\">\u66f4\u591a \u25be<\/a><\/span>\n  <a class=\"navtel\" href=\"tel:02886131795\">028-86131795<\/a>\n<\/div>\n<div class=\"sub\" id=\"navsub\">\n  <a href=\"#faq\">\u5e38\u89c1\u95ee\u9898<\/a>\n  <a href=\"#more\">\u4e86\u89e3\u66f4\u591a<\/a>\n  <a href=\"#certs\">\u54c1\u724c\u6388\u6743<\/a>\n  <a href=\"#stores\">\u6388\u6743\u95e8\u5e97<\/a>\n  <a href=\"#annex\">\u8f85\u6750\u6e05\u5355<\/a>\n<\/div><\/nav>\n\n<!-- GEO \u4fe1\u606f\u5361\uff08\u6574\u5361\u7ffb\u8f6c\uff1a\u6b63=\u9879\u76ee\u901f\u89c8 \/ \u53cd=\u9009\u578b\u903b\u8f91\u4e0e\u6280\u672f\u5907\u6ce8\uff09 -->\n<div class=\"geosec\">\n  <div class=\"wrap\">\n    <div class=\"geocard\" tabindex=\"0\"><div class=\"ginner\">\n      <div class=\"gface gfront\">\n        <div class=\"gtitle\">\n          <h3>\u9879\u76ee\u901f\u89c8 \u00b7 GEO \u4fe1\u606f\u5361<\/h3>\n          <span class=\"gid\">\u65b9\u6848\u7f16\u53f7 NFS-WCLD-ZLS-20260801-FA01<\/span>\n        <\/div>\n        <p class=\"gsum\">\u6210\u90fd\u9e93\u6e56\u751f\u6001\u57ce\u4e94\u5f69\u6797\u5824\u590d\u5f0f\u6d0b\u623f\uff0c\u91c7\u6696\u9762\u79ef130\u33a1\u3001\u5e38\u4f4f3\uff5e4\u4eba\uff0c\u505a\u4e2d\u592e\u7a7a\u8c03\uff0b\u5730\u6696\uff0b\u65b0\u98ce\u7684\u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\uff0c\u672c\u4e66\u7ed9\u51fa\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab\uff0b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e09\u5957\u6a2a\u5411\u5bf9\u6bd4\u4e0e20\u5e74\u603b\u8d26\u3002<\/p>\n        <div class=\"ggrid\">\n          <div><span>\u5c0f\u533a \/ \u5730\u57df<\/span><b>\u9e93\u6e56\u4e94\u5f69\u6797\u5824 \u00b7 \u6210\u90fd\u5929\u5e9c\u65b0\u533a<\/b><\/div>\n          <div><span>\u6237\u578b<\/span><b>\u590d\u5f0f\u6d0b\u623f\uff08\u4e0a\u4e0b\u4e24\u5c42\u00b7\u516d\u4e2a\u623f\u95f4\uff09<\/b><\/div>\n          <div><span>\u91c7\u6696\u9762\u79ef<\/span><b>130\u33a1\uff08\u7a7a\u8c03\u8986\u76d6127.8\u33a1\uff09<\/b><\/div>\n          <div><span>\u70ed\u6e90<\/span><b>\u5c0a\u777f\u5168\u6548180 \/ \u6c34\u5885\u9002180 \/ \u83f2\u65af\u66fcB1JG25<\/b><\/div>\n          <div><span>\u8f93\u914d<\/span><b>\u65b9\u6848\u4e00 \u6c1f\uff0b160\u6c34\u6a21\u5757 \u00b7 \u65b9\u6848\u4e8c \u5168\u6c34 \u00b7 \u65b9\u6848\u4e09 \u6c1f\uff0b\u72ec\u7acb\u9505\u7089<\/b><\/div>\n          <div><span>\u672b\u7aef<\/span><b>\u5185\u673a\u00d76 \uff0b \u5730\u6696130\u33a1 \uff0b \u5929\u51c0\u65b0\u98ce350<\/b><\/div>\n          <div><span>\u9636\u6bb5<\/span><b>\u65b9\u6848\u5bf9\u6bd4\u671f Phase 1\uff08\u672a\u7b7e\u7ea6\uff09<\/b><\/div>\n          <div><span>\u5bf9\u63a5\u95e8\u5e97<\/span><b>\u5357\u5bcc\u68ee\u65d7\u8230\u5e97 \u00b7 \u987e\u95ee\u4f59\u6653\u73b2<\/b><\/div>\n        <\/div>\n        <div class=\"ghint\">\u60ac\u505c\u6216\u70b9\u51fb\u672c\u5361\uff0c\u7ffb\u8f6c\u67e5\u770b\u9009\u578b\u903b\u8f91\u4e0e\u6280\u672f\u5907\u6ce8\u3002<\/div>\n      <\/div>\n      <div class=\"gface gback\">\n        <div class=\"gtitle\">\n          <h3>\u9009\u578b\u903b\u8f91\u4e0e\u6280\u672f\u5907\u6ce8<\/h3>\n          <span class=\"gid\">Phase 1 \u00b7 \u5f85\u5e73\u9762\u56fe\u9501\u5b9a<\/span>\n        <\/div>\n        <p class=\"gsum\">\u540c\u4e00\u5957\u5185\u673a\u51b7\u91cf\u3001\u540c\u4e00\u5957\u5730\u6696\u9762\u79ef\uff0c\u4e09\u65b9\u6848\u53ea\u5728\u201c\u4e3b\u673a\u7cfb\u7edf\u4e0e\u4ecb\u8d28\u201d\u4e0a\u5206\u53c9\u2014\u2014\u8fd9\u6837\u624d\u80fd\u6a2a\u5411\u53ef\u6bd4\u3002<\/p>\n        <ul class=\"glist\">\n          <li><b>\u9009\u578b\u4e3b\u7ebf<\/b>\uff1a\u5e38\u4f4f3\uff5e4\u4eba\u3001\u516d\u5ba4\u5e38\u5f002\uff5e3\u53f0\uff08\u540c\u5f00\u7387\u7ea640%\uff5e50%\uff09\u3001\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\uff0c\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11\uff0c\u6700\u5339\u914d\u201c\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\u201d\u7684\u8bc9\u6c42\u3002<\/li>\n          <li><b>\u6c34\u673a\u9002\u7528\u8fb9\u754c<\/b>\uff1a\u6c34\u5885\u9002\u201c\u8bbe\u8ba1\u81ea\u7531\u3001\u51fa\u98ce\u67d4\u548c\u201d\u7684\u4f18\u52bf\u9700\u4f4e\u540c\u5f00\u7387<em>\u4e14<\/em>\u5927\u4f53\u91cf\uff08\u901a\u5e38200\u33a1\u4ee5\u4e0a\uff09\u624d\u5212\u7b97\uff0c\u672c\u6237130\u33a1\u672a\u5230\u4e34\u754c\u70b9\uff0c\u6545\u5217\u4e3a\u5bf9\u6bd4\u9879\u800c\u975e\u9996\u63a8\u3002<\/li>\n          <li><b>\u8d85\u914d\u7387\u6821\u9a8c<\/b>\uff1a\u6c1f\u7cfb\u7edf\u5185\u673a\u5408\u8ba120.3kW \/ \u4e3b\u673a18kW \u2248 113%\uff0c\u843d\u5728\u2264130%\u7684\u5408\u89c4\u533a\u95f4\uff08\u7406\u60f390%\uff5e110%\uff09\u3002<\/li>\n          <li><b>\u91c7\u6696\u70ed\u6c34\u5206\u79bb<\/b>\uff1a\u70ed\u6c34\u4fa7\u4e0d\u4e0e\u91c7\u6696\u5171\u7528\u70ed\u6e90\uff0c\u9884\u7559\u96f6\u51b7\u6c34\u5faa\u73af\u63a5\u53e3\uff0c\u4e24\u536b\u540c\u5f00\u6309\u6c34\u529b\u8bbe\u8ba1\u800c\u975e\u653e\u5927\u6c34\u7bb1\u89e3\u51b3\u3002<\/li>\n          <li><b>\u4ef7\u683c\u6765\u6e90<\/b>\uff1a\u5168\u90e8\u5f15\u81ea\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff08page_id 662\uff09\uff0c\u6298\u6263\u53e3\u5f84\u89c1S4\uff1b\u8fd0\u884c\u8d39\u4e0e\u7ef4\u62a4\u8d39\u4e3a\u4f30\u7b97\u503c\u5e76\u5df2\u663e\u5f0f\u6807\u6ce8\u3002<\/li>\n          <li><b>\u8fd0\u884c\u8d39\u53e3\u5f84<\/b>\uff1a\u91c7\u6696\u5b63110\u5929\u3001\u5236\u51b7\u5b6390\u5929\u3001\u65b0\u98ce\u5168\u5e74365\u5929\u5206\u6bb5\u6d4b\u7b97\u3002\u4e24\u4e2a\u4e8c\u8054\u4f9b\u91c7\u6696\u4fa7\u540c\u4e3a\u70ed\u6cf5\u5236\u70ed\u6c34\u9001\u5730\u6696\uff0c\u91c7\u6696\u8d39\u4e00\u81f4\uff1b\u5dee\u5f02\u4ec5\u5728\u5236\u51b7\u4fa7\uff08\u6c34\u7cfb\u7edf\u4e8c\u6b21\u6362\u70ed\uff0b\u5faa\u73af\u6cf5\uff09\u3002\u51b7\u51dd\u7089\u70e7\u6c14\u91c7\u6696\u8d39\u6700\u9ad8\uff0c\u4e1420\u5e74\u5185\u9700\u4e8c\u6b21\u8d2d\u7f6e1\u6b21\u3002<\/li>\n        <\/ul>\n        <div class=\"ghint\">\u672c\u9875\u4e3a\u5bf9\u5185\u65b9\u6848\u6863\u6848\uff08noindex\uff09\uff0c\u6b63\u5f0f\u5e73\u9762\u56fe\u786e\u8ba4\u540e\u8f6c\u7b7e\u7ea6\u7248\u3002<\/div>\n      <\/div>\n    <\/div><\/div>\n  <\/div>\n<\/div>\n\n<!-- S1 \u5ba2\u6237\u6210\u529f\u76ee\u6807 -->\n<section id=\"s1\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">S1<\/div><h2>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2><\/div>\n    <p class=\"sec-sub\">\u5148\u7406\u89e3\u4eba\uff0c\u518d\u8bbe\u8ba1\u65b9\u6848\u3002\u5f20\u8001\u5e08\u7684\u5173\u6ce8\u70b9\uff0c\u5c31\u662f\u672c\u65b9\u6848\u6bcf\u4e00\u9875\u7684\u8bc4\u5206\u6807\u51c6\u3002<\/p>\n    <div class=\"profile\">\n      <div class=\"pbox\">\n        <h3>\u5ba2\u6237\u753b\u50cf<\/h3>\n        <div class=\"kv\"><span>\u65b9\u6848\u7f16\u53f7<\/span><b>NFS-WCLD-ZLS-20260801-FA01<\/b><\/div>\n        <div class=\"kv\"><span>\u6c9f\u901a\u65e5\u671f<\/span><b>2026-08-01 \u00b7 \u5357\u5bcc\u68ee\u8fdb\u5e97\uff08\u4f59\u6653\u73b2\u8bb0\u5f55\uff09<\/b><\/div>\n        <div class=\"kv\"><span>\u51b3\u7b56\u7279\u5f81<\/span><b>\u505a\u529f\u8bfe\u578b\u5ba2\u6237 \u00b7 \u6c9f\u901a\u6210\u672c\u4f4e<\/b><\/div>\n        <div class=\"kv\"><span>\u5230\u5e97\u8def\u5f84<\/span><b>\u7f51\u4e0a\u641c\u7d22\u5bf9\u6bd4\u540e\u4e3b\u52a8\u9009\u9f99\u8109\u5357\u5bcc\u68ee<\/b><\/div>\n        <div class=\"kv\"><span>\u6838\u5fc3\u8bc9\u6c42<\/span><b>\u4e8c\u8054\u4f9b\u9009\u578b\uff08\u5929\u6c1f\u5730\u6c34 vs \u5929\u6c34\u5730\u6c34\uff09<\/b><\/div>\n        <div class=\"kv\"><span>\u660e\u786e\u9700\u6c42<\/span><b>\u6210\u90fd\u96fe\u973e\u91cd \u00b7 \u51c0\u5316\u529f\u80fd\u5fc5\u987b\u5230\u4f4d<\/b><\/div>\n        <div class=\"kv\"><span>\u5174\u8da3\u65b9\u5411<\/span><b>\u4e94\u6052\u7cfb\u7edf\uff08\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\uff09<\/b><\/div>\n        <div class=\"kv\"><span>\u9690\u853d\u987e\u8651<\/span><b>\u5b89\u88c5\u8d28\u91cf \u00b7 \u7cfb\u7edf\u7a33\u5b9a \u00b7 \u8d28\u4fdd\u653f\u7b56<\/b><\/div>\n        <div class=\"kv\"><span>\u5e38\u4f4f\u4eba\u6570<\/span><b>3\uff5e4\u4eba\uff08\u5df2\u786e\u8ba4\uff09<\/b><\/div>\n        <div class=\"kv\"><span>\u540c\u5f00\u7387\u63a8\u7b97<\/span><b>6\u5ba4\u5e38\u5f002\uff5e3\u53f0 \u00b7 \u7ea640%\uff5e50%<\/b><\/div>\n      <\/div>\n      <div class=\"pbox\">\n        <h3>\u4e94\u5927\u5173\u6ce8\u6743\u91cd<\/h3>\n        <ul class=\"weights\">\n          <li><span class=\"wname\">\u51b7\u6696\u7cfb\u7edf\u9009\u578b<\/span><span class=\"wbar\"><i style=\"width:100%\"><\/i><\/span><span class=\"stars\">5\/5<\/span><\/li>\n          <li><span class=\"wname\">\u7a7a\u6c14\u51c0\u5316<\/span><span class=\"wbar\"><i style=\"width:100%\"><\/i><\/span><span class=\"stars\">5\/5<\/span><\/li>\n          <li><span class=\"wname\">\u4e94\u6052\u7cfb\u7edf<\/span><span class=\"wbar\"><i style=\"width:80%\"><\/i><\/span><span class=\"stars\">4\/5<\/span><\/li>\n          <li><span class=\"wname\">\u70ed\u6c34\u7cfb\u7edf<\/span><span class=\"wbar\"><i style=\"width:80%\"><\/i><\/span><span class=\"stars\">4\/5<\/span><\/li>\n          <li><span class=\"wname\">\u5b89\u88c5\u4e0e\u552e\u540e<\/span><span class=\"wbar\"><i style=\"width:80%\"><\/i><\/span><span class=\"stars\">4\/5<\/span><\/li>\n        <\/ul>\n        <div class=\"note\">\u987e\u95ee\u5173\u952e\u8ba4\u77e5\uff1a\u70ed\u6c34\u662f\u7cfb\u7edf\u95ee\u9898\uff08\u7ba1\u8def\u8bbe\u8ba1\u624d\u662f\u5173\u952e\uff09\uff1b\u6c34\u673a\u5728\u5e73\u5c42\u5e38\u5f00\u573a\u666f\u4f18\u52bf\u4e0d\u660e\u663e\uff08\u7ed3\u6784\u590d\u6742\u3001\u6545\u969c\u70b9\u591a\uff09\uff1b\u4e94\u6052\u662f\u7ec4\u5408\u5f0f\u7cfb\u7edf\uff08AI\u96c6\u63a7\u7edf\u4e00\u7ba1\u7406\uff09\uff1b\u6052\u9759\u2260\u65e0\u58f0\uff08\u63a7\u5236\u5728\u5408\u7406\u5206\u8d1d\uff09\u3002<\/div>\n      <\/div>\n    <\/div>\n    <div class=\"note\"><b>\u539f\u59cb\u60f3\u6cd5\uff08\u539f\u59cb\u9700\u6c42\uff09\u5907\u6ce8<\/b>\uff1a\u5f20\u8001\u5e082026-08-01\u5357\u5bcc\u68ee\u8fdb\u5e97\u6c9f\u901a\uff0c\u660e\u786e\u8868\u8fbe\u201c\u503e\u5411\u4e8c\u8054\u4f9b\u3001\u60f3\u628a\u5bb6\u505a\u6210\u4e94\u6052\u201d\uff0c\u5e76\u4e3b\u52a8\u63d0\u51fa\u8981\u5bf9\u6bd4\u5929\u6c1f\u5730\u6c34\u4e0e\u5929\u6c34\u5730\u6c34\u4e24\u6761\u6280\u672f\u8def\u7ebf\uff1b\u5efa\u7b51\u8be6\u60c5\uff08\u590d\u5f0f\u6d0b\u623f\u3001\u91c7\u6696130\u33a1\u3001\u516d\u623f\u95f4\u9762\u79ef\u4e0e\u5185\u673a\u5bb9\u91cf\uff09\u7531\u5ba2\u6237\u73b0\u573a\u63d0\u4f9b\u3002\u672c\u65b9\u6848\u4e66\u5373\u56f4\u7ed5\u8be5\u539f\u59cb\u60f3\u6cd5\u5c55\u5f00\u4e09\u65b9\u6848\u6a2a\u5411\u5bf9\u6bd4\uff0c\u4e0d\u66ff\u5ba2\u6237\u505a\u51b3\u5b9a\u3002\u8bb0\u5f55\u4eba\uff1a\u5357\u5bcc\u68ee\u95e8\u5e97\u987e\u95ee \u4f59\u6653\u73b2\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S2 \u65b9\u6848\u8bca\u65ad -->\n<section id=\"s2\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">S2<\/div><h2>\u65b9\u6848\u8bca\u65ad<\/h2><\/div>\n    <p class=\"sec-sub\">\u8bca\u65ad\u7ed3\u8bba\uff1a\u590d\u5f0f\u6d0b\u623f\u91c7\u6696130\u33a1\u3001\u5e38\u4f4f3\uff5e4\u4eba\u3001\u516d\u5ba4\u5e38\u5f002\uff5e3\u53f0\uff08\u540c\u5f00\u7387\u7ea640%\uff5e50%\uff09\u3001\u8ffd\u6c42\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\uff0c\u5929\u6c1f\u5730\u6c34\u66f4\u5339\u914d\u3002\u6c34\u673a\u7684\u201c\u8bbe\u8ba1\u81ea\u7531\u201d\u4f18\u52bf\u5728\u4f4e\u540c\u5f00\u7387\u5927\u6237\u578b\u624d\u663e\u73b0\uff0c\u672c\u6237\u4f53\u91cf\u4e0b\u4e0d\u8db3\u4ee5\u62b5\u6d88\u5176\u90e8\u4ef6\u591a\u3001\u7ef4\u62a4\u9ad8\u7684\u4ee3\u4ef7\u3002<\/p>\n    <div class=\"tabs\">\n      <div class=\"tab active\" data-t=\"t1\">\u9009\u578b\u903b\u8f91<\/div>\n      <div class=\"tab\" data-t=\"t2\">\u4e94\u6052\u6846\u67b6<\/div>\n      <div class=\"tab\" data-t=\"t3\">\u4f53\u9a8c \/ \u6280\u672f \/ \u8fd0\u7ef4<\/div>\n    <\/div>\n    <div class=\"tabpane active\" id=\"t1\">\n      <div class=\"card\">\n        <h3>\u5929\u6c1f\u5730\u6c34\uff08\u65b9\u6848\u4e00\uff09 vs \u5929\u6c34\u5730\u6c34\uff08\u65b9\u6848\u4e8c\uff09<\/h3>\n        <table class=\"tbl\">\n          <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u5929\u6c1f\u5730\u6c34 \u00b7 \u5c0a\u777f\u5168\u6548<\/th><th>\u5929\u6c34\u5730\u6c34 \u00b7 \u6c34\u5885\u9002<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td class=\"pl\">\u7a7a\u8c03\u4fa7\u4ecb\u8d28<\/td><td>\u51b7\u5a92\uff08\u6c1f\uff09\uff0c\u4ec5\u5730\u6696\u4fa7\u8d70\u6c34<\/td><td>\u7a7a\u8c03\u4e0e\u5730\u6696\u4e24\u4fa7\u90fd\u8d70\u6c34<\/td><\/tr>\n            <tr><td class=\"pl\">\u7cfb\u7edf\u590d\u6742\u5ea6<\/td><td><span class=\"hi\">\u7b80\u6d01\uff0c\u6545\u969c\u70b9\u5c11<\/span><\/td><td>\u90e8\u4ef6\u591a\uff08\u6c34\u6cf5\/\u677f\u6362\/\u8865\u6c34\u9600\uff09<\/td><\/tr>\n            <tr><td class=\"pl\">\u51fa\u98ce\u4f53\u611f<\/td><td>\u6c1f\u673a\u5f3a\u51b7\u5f3a\u70ed\uff0c\u7cbe\u51c6<\/td><td><span class=\"hi\">\u51fa\u98ce\u66f4\u67d4\u548c<\/span><\/td><\/tr>\n            <tr><td class=\"pl\">\u9002\u914d\u573a\u666f<\/td><td><span class=\"hi\">\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\u3001\u6c42\u7a33\u5b9a<\/span><\/td><td>\u4f4e\u540c\u5f00\u7387\u5927\u6237\u578b\u3001\u8bbe\u8ba1\u81ea\u7531<\/td><\/tr>\n            <tr><td class=\"pl\">\u672c\u6237\u540c\u5f00\u7387<\/td><td colspan=\"2\">\u5e38\u4f4f3\uff5e4\u4eba \/ \u516d\u4e2a\u623f\u95f4\u5e38\u5f002\uff5e3\u53f0\uff0c\u540c\u5f00\u7387\u7ea640%\uff5e50%\uff08\u4e2d\u7b49\u504f\u4f4e\uff09<\/td><\/tr>\n            <tr><td class=\"pl\">\u987e\u95ee\u7ed3\u8bba<\/td><td colspan=\"2\">\u590d\u5f0f\u6d0b\u623f\u91c7\u6696130\u33a1\u3001\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\uff08\u4e00\u697c\u5ba2\u9910\u5385+\u4e8c\u697c\u4e3b\u5367\uff09\u3001\u5ba2\u6237\u8981\u201c\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\u201d\uff0c<b>\u5929\u6c1f\u5730\u6c34\u66f4\u5339\u914d<\/b>\uff1b\u6c34\u673a\u9700\u4f4e\u540c\u5f00\u7387<em>\u4e14<\/em>\u5927\u4f53\u91cf\u624d\u5212\u7b97\uff0c\u672c\u6237130\u33a1\u672a\u5230\u4e34\u754c\u70b9<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n    <\/div>\n    <div class=\"tabpane\" id=\"t2\">\n      <div class=\"grid g2\">\n        <div class=\"card\"><h3>\u6052\u6e29 \u00b7 \u4e8c\u8054\u4f9b\u7a7a\u8c03\u5730\u6696\u4e00\u4f53<\/h3><p>\u51ac\u5929\u5730\u6696\u3001\u590f\u5929\u7a7a\u8c03\u540c\u6e90\u63a7\u5236\uff0c\u544a\u522b\u51b7\u6696\u4e24\u5957\u9065\u63a7\u5668\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u6052\u6e7f \u00b7 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/h3><p>\u65b9\u6848\u4e00\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\u72ec\u7acb\u9664\u6e7f\u518d\u70ed\uff0c\u6885\u96e8\u56de\u5357\u5929\u4e0d\u9709\u4e0d\u9ecf\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u6052\u6c27 \u00b7 \u5929\u51c0\u65b0\u98ce\u7cfb\u7edf<\/h3><p>350\u98ce\u91cf\u4ee5\u4e8c\u5c42\u5367\u5ba4\u4e3a\u4e3b\uff0c\u4fdd\u8bc1\u7761\u7720\u533a\u6362\u6c14\u4e0e\u96fe\u973e\u8fc7\u6ee4\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u6052\u6d01 \u00b7 PE\u51c0\u5316\u5185\u673a\u6a21\u5757<\/h3><p>\u5185\u673a\u96c6\u6210\u51c0\u5316\uff0c\u89e3\u51b3\u6210\u90fd\u51ac\u5b63\u96fe\u973e\u4e0e\u5ba4\u5185\u7a7a\u6c14\u6d01\u51c0\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u6052\u9759 \u00b7 \u4f4e\u566a+\u7cbe\u5de5\u5b89\u88c5<\/h3><p>\u4f4e\u566a\u8bbe\u5907\u914d\u5408\u9f99\u8109\u7cbe\u5de5\u89c4\u8303\uff0c\u63a7\u5236\u5728\u5408\u7406\u5206\u8d1d\uff08\u975e\u65e0\u58f0\uff09\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u96c6\u63a7 \u00b7 \u65e5\u7acb\u5168\u611f2.0<\/h3><p>\u65e5\u7acb\u96c6\u63a7\u5c4f\u7edf\u4e00\u8c03\u5ea6\uff0c\u4e94\u6052\u7531AI\u96c6\u63a7\u7edf\u4e00\u7ba1\u7406\uff0c\u800c\u975e\u5355\u4e00\u4ea7\u54c1\u3002<\/p><\/div>\n      <\/div>\n    <\/div>\n    <div class=\"tabpane\" id=\"t3\">\n      <div class=\"grid g3\">\n        <div class=\"card\"><h3>\u4f53\u9a8c<\/h3><p>\u5367\u5ba4\u4f18\u5148\u65b0\u98ce\u3001\u6e29\u6e7f\u53cc\u63a7\u4e0d\u95f7\u4e0d\u71e5\u3001\u5168\u5c4b\u4e00\u952e\u96c6\u63a7\uff0c\u8001\u4eba\u5c0f\u5b69\u90fd\u597d\u7528\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u6280\u672f<\/h3><p>\u8d85\u914d\u7387\u6821\u9a8c\uff1a\u6c1f\u673a\u65b9\u684820.3kW\/18kW\u2248113%\uff08\u2264130%\u8fbe\u6807\uff09\uff1b\u6c34\u673a\u98ce\u673a\u76d8\u7ba1\u6309\u6c34\u7cfb\u7edf\u7279\u6027\u914d\u7f6e\u3002<\/p><\/div>\n        <div class=\"card\"><h3>\u8fd0\u7ef4<\/h3><p>\u8f85\u6750\u6e05\u5355\u5168\u90e8\u9ed8\u8ba4\u89c4\u683c\u3001\u54c1\u724c\u552f\u4e00\uff1b\u4f1f\u661f\u661f\u76d1\u7406\u7b2c\u4e09\u65b9\u6253\u538b\uff1b\u5730\u6696\u4e09\u65b9\u8054\u4fdd50\u5e74\u3002<\/p><\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- S3 \u7cfb\u7edf\u8bbe\u8ba1 -->\n<section id=\"s3\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">S3<\/div><h2>\u7cfb\u7edf\u8bbe\u8ba1 \u00b7 \u4e09\u65b9\u6848\u914d\u7f6e<\/h2><\/div>\n    <p class=\"sec-sub\">\u516d\u4e2a\u623f\u95f4\u7edf\u4e00\u914d\u7f6e\uff08\u9910\u538538.8\/\u5ba2\u538529.5\/\u6b21\u536711\/\u4e66\u623f11.4\/\u4e3b\u5367\u8863\u5e3d\u95f423.1\/\u6b21\u536713\u33a1\uff09\uff0c\u4e09\u65b9\u6848\u5185\u673a\u5bb9\u91cf\u5339\u914d\u4e00\u81f4\uff0c\u5dee\u5f02\u5728\u4e3b\u673a\u7cfb\u7edf\u4e0e\u4ecb\u8d28\u3002<\/p>\n    <div class=\"note\"><b>\u547d\u540d\u8bf4\u660e\uff08\u56fa\u5316\u547d\u540d\u8c41\u514d\uff09<\/b>\uff1a\u672c\u65b9\u6848\u4e66\u4e3a<b>\u4e09\u79cd\u7cfb\u7edf\u7c7b\u578b\u7684\u6a2a\u5411\u6280\u672f\u5bf9\u6bd4<\/b>\uff08\u5929\u6c1f\u5730\u6c34 \/ \u5929\u6c34\u5730\u6c34 \/ \u6c1f\u673a\uff0b\u72ec\u7acb\u9505\u7089\uff09\uff0c\u5e76\u975e\u201c\u539f\u59cb\u60f3\u6cd5\u9700\u6c42 \/ \u6027\u4ef7\u6bd4\u63a8\u8350 \/ 20\u5e74\u957f\u6548\u4f18\u9009\u201d\u7684\u4e09\u6863\u9012\u8fdb\u65b9\u6848\uff0c\u6545\u6309\u591a\u65b9\u6848\u5bf9\u6bd4\u573a\u666f\u8c41\u514d\u4e09\u6863\u56fa\u5316\u547d\u540d\uff0c\u6539\u4ee5\u7cfb\u7edf\u7c7b\u578b\u547d\u540d\u4ee5\u907f\u514d\u8bef\u5bfc\u3002\u4e09\u65b9\u6848\u5730\u6696\u9762\u79ef\u3001\u5185\u673a\u51b7\u91cf\u3001\u65b0\u98ce\u914d\u7f6e\u4fdd\u6301\u4e00\u81f4\uff0c\u786e\u4fdd\u53e3\u5f84\u53ef\u76f4\u63a5\u6a2a\u5411\u6bd4\u8f83\u3002<\/div>\n\n    <h3 style=\"color:var(--navy-d);margin:8px 0 8px\">\u4ea7\u54c1\u7ffb\u8f6c\u5361\uff08\u6b63\uff1a\u4ea7\u54c1\u5f62\u8c61 \/ \u53cd\uff1a\u6838\u5fc3\u5356\u70b9\uff09<\/h3>\n    <p class=\"fhint\">\u9f20\u6807\u60ac\u505c\u6216\u70b9\u51fb\u5361\u7247\u53ef\u7ffb\u8f6c\u67e5\u770b\u6838\u5fc3\u5356\u70b9\u4e0e\u4ea7\u54c1\u8be6\u60c5\u94fe\u63a5\u3002<\/p>\n    <div class=\"flip\">\n      <div class=\"fcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face front\">\n          <div class=\"pimg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" alt=\"\u65e5\u7acbVAM\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u4e2d\u592e\u7a7a\u8c03\u4e3b\u673a\"><\/div>\n          <div class=\"pt\"><h4>\u65e5\u7acb\u5c0a\u777f\u5168\u6548 \u00b7 \u4e09\u7ba1\u5236<\/h4><div class=\"sub\">\u65b9\u6848\u4e00 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e94\u6052\u65d7\u8230<\/div><span class=\"badge\">\u987e\u95ee\u63a8\u8350<\/span><\/div>\n        <\/div>\n        <div class=\"face back\"><h4>\u6838\u5fc3\u5356\u70b9<\/h4><ul>\n          <li>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff08\u6052\u6e7f\uff09<\/li><li>PE\u51c0\u5316\u5185\u673a\u6a21\u5757\uff08\u6052\u6d01\uff09<\/li><li>160\u6c34\u6a21\u5757\u76f4\u5e26\u5730\u6696130\u33a1<\/li><li>\u65e5\u7acb\u96c6\u63a7\u5c4f \u00b7 \u5168\u611f2.0\u4e94\u6052<\/li><li>\u7cfb\u7edf\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11<\/li>\n        <\/ul><div class=\"flink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1811\" style=\"color:var(--gold)\">\u67e5\u770b\u5c0a\u777f\u5168\u6548\u4ea7\u54c1\u8be6\u60c5 \u00b7 page_id 1811<\/a><\/div><\/div>\n      <\/div><\/div>\n      <div class=\"fcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face front\">\n          <div class=\"pimg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E6%B0%B4%E5%A2%85%E9%80%82VF05.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u6c34\u673a\u4e3b\u673a\"><\/div>\n          <div class=\"pt\"><h4>\u65e5\u7acb\u6c34\u5885\u9002 \u00b7 \u4e24\u8054\u4f9b<\/h4><div class=\"sub\">\u65b9\u6848\u4e8c \u00b7 \u5929\u6c34\u5730\u6c34\u5168\u6c34\u7cfb\u7edf<\/div><span class=\"badge\">\u51fa\u98ce\u67d4\u548c<\/span><\/div>\n        <\/div>\n        <div class=\"face back\"><h4>\u6838\u5fc3\u5356\u70b9<\/h4><ul>\n          <li>\u7a7a\u8c03\u5730\u6696\u53cc\u4fa7\u8d70\u6c34\uff0c\u540c\u6e90\u4e00\u4f53<\/li><li>\u51fa\u98ce\u67d4\u548c\u3001\u4f53\u611f\u66f4\u63a5\u8fd1\u81ea\u7136\u98ce<\/li><li>RFP\u7cfb\u5217\u98ce\u673a\u76d8\u7ba1\u5185\u673a\u00d76<\/li><li>\u4e3b\u673a\u4e0e\u672b\u7aef\u8bbe\u8ba1\u81ea\u7531\u5ea6\u9ad8<\/li><li>\u9002\u5408\u4f4e\u540c\u5f00\u7387\u5927\u6237\u578b<\/li>\n        <\/ul><div class=\"flink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1233\" style=\"color:var(--gold)\">\u67e5\u770b\u6c34\u5885\u9002\u4ea7\u54c1\u8be6\u60c5 \u00b7 page_id 1233<\/a><\/div><\/div>\n      <\/div><\/div>\n      <div class=\"fcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face front\">\n          <div class=\"pimg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p21-01.jpeg\" alt=\"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\"><\/div>\n          <div class=\"pt\"><h4>\u65e5\u7acb\u8212\u4eab \u00b7 \u4e00\u62d6\u516d<\/h4><div class=\"sub\">\u65b9\u6848\u4e09 \u00b7 \u6c1f\u673a+\u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/div><span class=\"badge\">\u521d\u6295\u53ef\u63a7<\/span><\/div>\n        <\/div>\n        <div class=\"face back\"><h4>\u6838\u5fc3\u5356\u70b9<\/h4><ul>\n          <li>\u8212\u4eab180\u4e00\u62d6\u516d\u6c1f\u673a\uff088\u6298\uff09<\/li><li>\u83f2\u65af\u66fcB1JG25\u51b7\u51dd\u7089\u72ec\u7acb\u5730\u6696<\/li><li>\u91c7\u6696\u70ed\u6c34\u5206\u79bb\uff0c\u4e92\u4e0d\u62a2\u8d1f\u8377<\/li><li>\u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u5730\u6696179\u5143\/\u33a1<\/li><li>\u6280\u672f\u6210\u719f\u3001\u914d\u4ef6\u901a\u7528\u597d\u7ef4\u62a4<\/li>\n        <\/ul><div class=\"flink\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" style=\"color:var(--gold)\">\u67e5\u770b\u8212\u4eab\u4ea7\u54c1\u8be6\u60c5 \u00b7 page_id 1077<\/a><\/div><\/div>\n      <\/div><\/div>\n    <\/div>\n\n    <h3 style=\"color:var(--navy-d);margin:28px 0 14px\">\u5185\u673a\u5bb9\u91cf\u914d\u7f6e\u8868\uff08\u516d\u623f\u95f4\uff09<\/h3>\n    <table class=\"tbl\">\n      <thead><tr><th>\u697c\u5c42\/\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u65b9\u6848\u4e00\/\u4e09 \u6c1f\u673a\u5185\u673a<\/th><th>\u65b9\u6848\u4e8c \u6c34\u5885\u9002RFP<\/th><th>\u5236\u51b7\u91cf<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"pl\">\u4e00\u697c \u9910\u5385<\/td><td>38.8\u33a1<\/td><td>RPIZ-56\uff085.6kW\uff09<\/td><td>RFP-136WAR\/DBT12Y(Z)03\/P\uff088.1kW\uff09<\/td><td>\u6ee1\u8db3<\/td><\/tr>\n        <tr><td class=\"pl\">\u4e00\u697c \u5ba2\u5385<\/td><td>29.5\u33a1<\/td><td>RPIZ-45\uff084.5kW\uff09<\/td><td>RFP-102WAR\/DBT12Y(Z)03\/P\uff086.4kW\uff09<\/td><td>\u6ee1\u8db3<\/td><\/tr>\n        <tr><td class=\"pl\">\u4e00\u697c \u6b21\u5367<\/td><td>11\u33a1<\/td><td>RPIZ-22\uff082.2kW\uff09<\/td><td>RFP-34WAR\/DBT12Y(Z)03\/P\uff082.5kW\uff09<\/td><td>\u6ee1\u8db3<\/td><\/tr>\n        <tr><td class=\"pl\">\u4e00\u697c \u4e66\u623f<\/td><td>11.4\u33a1<\/td><td>RPIZ-22\uff082.2kW\uff09<\/td><td>RFP-34WAR\/DBT12Y(Z)03\/P\uff082.5kW\uff09<\/td><td>\u6ee1\u8db3<\/td><\/tr>\n        <tr><td class=\"pl\">\u4e8c\u697c \u4e3b\u5367\u8863\u5e3d\u95f4<\/td><td>23.1\u33a1<\/td><td>RPIZ-36\uff083.6kW\uff09<\/td><td>RFP-85WAR\/DBT12Y(Z)03\/P\uff085.7kW\uff09<\/td><td>\u6ee1\u8db3<\/td><\/tr>\n        <tr><td class=\"pl\">\u4e8c\u697c \u6b21\u5367<\/td><td>13\u33a1<\/td><td>RPIZ-22\uff082.2kW\uff09<\/td><td>RFP-51WAR\/DBT12Y(Z)03\/P\uff083.45kW\uff09<\/td><td>\u6ee1\u8db3<\/td><\/tr>\n        <tr><td class=\"pl\">\u5408\u8ba1\uff08\u6c1f\u673a\u51b7\u91cf\uff09<\/td><td>127.8\u33a1<\/td><td colspan=\"2\">20.3kW \/ \u4e3b\u673a18kW<\/td><td>\u8d85\u914d\u2248113%<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <h3 style=\"color:var(--navy-d);margin:28px 0 14px\">\u4e09\u65b9\u6848\u4e3b\u673a\u4e0e\u7cfb\u7edf\u6784\u6210<\/h3>\n    <table class=\"tbl\">\n      <thead><tr><th>\u7cfb\u7edf\u6784\u6210<\/th><th>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548\u4e94\u6052<\/th><th>\u65b9\u6848\u4e8c \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"pl\">\u7a7a\u8c03\u4e3b\u673a<\/td><td>\u5c0a\u777f\u5168\u6548 RAS-180FSXPN5Q<\/td><td>\u6c34\u5885\u9002 RAS-180FPUEN2Q\/M<\/td><td>\u8212\u4eab RAS-180HRNAQ<\/td><\/tr>\n        <tr><td class=\"pl\">\u5185\u673a\u5f62\u5f0f<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a\u00d76<\/td><td>RFP\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\u00d76\uff08DBT\/P\uff09<\/td><td>\u8212\u4eabDC\u5185\u673a\u00d76<\/td><\/tr>\n        <tr><td class=\"pl\">\u5730\u6696\/\u6c34\u6a21\u5757<\/td><td>160\u6c34\u6a21\u5757 + \u5730\u6696130\u33a1<\/td><td>\u6c34\u673a\u5730\u6696 + \u5730\u6696130\u33a1<\/td><td>\u83f2\u65af\u66fcB1JG25\u9505\u7089 + \u5730\u6696130\u33a1<\/td><\/tr>\n        <tr><td class=\"pl\">\u65b0\u98ce<\/td><td>\u5929\u51c0\u65b0\u98ce350\uff08\u4e8c\u5c42\u5367\u5ba4\u4e3a\u4e3b\uff09<\/td><td>\u5929\u51c0\u65b0\u98ce350<\/td><td>\u65e5\u7acb\u5929\u51c0\u65b0\u98ce<\/td><\/tr>\n        <tr><td class=\"pl\">\u96c6\u63a7<\/td><td>\u65e5\u7acb\u96c6\u63a7\u5c4f\u00b7\u5168\u611f2.0\u4e94\u6052<\/td><td>\u5e38\u89c4\u63a7\u5236<\/td><td>\u5e38\u89c4\u63a7\u5236<\/td><\/tr>\n        <tr><td class=\"pl\">\u70ed\u6c34<\/td><td colspan=\"3\">\u9884\u7559\u96f6\u51b7\u6c34\u5faa\u73af\u63a5\u53e3\uff0c\u7b7e\u7ea6\u540e\u6309\u4e24\u536b\u540c\u5f00\u7387\u51fa\u7ec6\u5316\u7ba1\u8def\u56fe<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- S4 \u900f\u660e\u62a5\u4ef7 -->\n<section id=\"s4\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">S4<\/div><h2>\u900f\u660e\u62a5\u4ef7 \u00b7 \u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2><\/div>\n    <p class=\"sec-sub\">\u4ef7\u683c\u4e25\u683c\u5f15\u81ea\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff08page_id=662\uff09\uff1a\u8212\u4eab8\u6298 \/ \u5c0a\u777f\u5168\u65488.5\u6298 \/ \u6c34\u5885\u9002\u96f6\u552e\u4ef7\u4e0d\u6253\u6298 \/ \u83f2\u65af\u66fc\u00b7\u5730\u6696\u5355\u4ef7\u4e0d\u6253\u6298 \/ 160\u6c34\u6a21\u5757\u6309\u672c\u5355\u7ea6\u5b9a\u4e0d\u6253\u6298 \/ \u5929\u51c0\u65b0\u98ce\u00b7\u96c6\u63a7\u5c4f\u9762\u4ef7\u5c0a\u777f\u7c7b8.5\u6298\u3002\u65b9\u6848\u4e8c\u516d\u53f0\u96f6\u8d8a\u98ce\u76d8\u89c4\u683c\u5404\u5f02\uff0c\u5df2\u6309\u578b\u53f7\u9010\u53f0\u6838\u4ef7\uff08\u660e\u7ec6\u8868\u89c1\u4e0b\uff09\uff0c\u4e0d\u6309\u5747\u4ef7\u4f30\u7b97\uff1b\u6c34\u7cfb\u7edf\u5b89\u88c5\u8d39\u6309\u672c\u5355\u53e3\u5f84\u8ba1\u53d6\uff1a\uff08\u5185\u673a6\u53f0\uff0b\u4e3b\u673a1\u53f0\uff09\u00d73,200\u5143\/\u53f0\u00d78\u6298\uff1d17,920\u5143\u3002\u8fd0\u884c\u8d39\u6309\u91c7\u6696\u5b63110\u5929\u3001\u5236\u51b7\u5b6390\u5929\u3001\u65b0\u98ce\u5168\u5e74365\u5929\u5206\u6bb5\u6d4b\u7b97\uff0c\u5168\u90e8\u53c2\u6570\u4e0e\u7b97\u5f0f\u5df2\u5728\u4e0b\u65b9\u300c\u5e74\u8fd0\u884c\u8d39\u6d4b\u7b97\u660e\u7ec6\u300d\u4e2d\u516c\u5f00\uff0c\u53ef\u9010\u9879\u9a8c\u7b97\u3002<\/p>\n\n    <div class=\"quote\">\n      <div class=\"qcard q1\">\n        <div class=\"qh\"><h3>\u65b9\u6848\u4e00<\/h3><div>\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u4e94\u6052<\/div><div class=\"price\">106,853<small> \u5143\uff08\u6298\u540e\u521d\u6295\uff09<\/small><\/div><\/div>\n        <div class=\"qb\">\n          <div class=\"qrow\"><span>\u5c0a\u777f\u5168\u6548180\u4e3b\u673a<\/span><b>20,506<\/b><\/div>\n          <div class=\"qrow\"><span>\u4e09\u7ba1\u5236\u5185\u673a\u00d76\uff08\u542b\u5b89\u88c5\uff09<\/span><b>38,272<\/b><\/div>\n          <div class=\"qrow\"><span>160\u6c34\u6a21\u5757\uff08\u4e0d\u6253\u6298\uff09<\/span><b>9,000<\/b><\/div>\n          <div class=\"qrow\"><span>\u5929\u51c0\u65b0\u98ce350\uff08\u542b\u5b89\u88c5\uff09<\/span><b>14,275<\/b><\/div>\n          <div class=\"qrow\"><span>\u65e5\u7acb\u96c6\u63a7\u5c4f<\/span><b>1,530<\/b><\/div>\n          <div class=\"qrow\"><span>\u5730\u6696130\u33a1\uff08179\u963b\u6c27\uff09<\/span><b>23,270<\/b><\/div>\n          <div class=\"rec\">\u987e\u95ee\u63a8\u8350 \u00b7 20\u5e74\u603b\u8d26\u6700\u4f4e<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"qcard q2\">\n        <div class=\"qh\"><h3>\u65b9\u6848\u4e8c<\/h3><div>\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e8c\u8054\u4f9b<\/div><div class=\"price\">104,499<small> \u5143\uff08\u6298\u540e\u521d\u6295\uff09<\/small><\/div><\/div>\n        <div class=\"qb\">\n          <div class=\"qrow\"><span>\u6c34\u5885\u9002180\u4e3b\u673a\uff08\u96f6\u552e\u4e0d\u6253\u6298\uff09<\/span><b>30,110<\/b><\/div>\n          <div class=\"qrow\"><span>RFP\u96f6\u8d8a\u98ce\u76d8\u00d76\uff08\u9010\u53f0\u6838\u4ef7\uff09<\/span><b>18,924<\/b><\/div>\n          <div class=\"qrow\"><span>\u6c34\u7cfb\u7edf\u5b89\u88c5\u8d39\uff087\u53f0\u00d73200\u00d78\u6298\uff09<\/span><b>17,920<\/b><\/div>\n          <div class=\"qrow\"><span>\u5929\u51c0\u65b0\u98ce350\uff08\u542b\u5b89\u88c5\uff09<\/span><b>14,275<\/b><\/div>\n          <div class=\"qrow\"><span>\u5730\u6696130\u33a1\uff08179\u963b\u6c27\uff09<\/span><b>23,270<\/b><\/div>\n          <div class=\"rec\" style=\"background:var(--muted)\">\u51fa\u98ce\u67d4\u548c \u00b7 \u7ef4\u62a4\u504f\u9ad8<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"qcard q3\">\n        <div class=\"qh\"><h3>\u65b9\u6848\u4e09<\/h3><div>\u8212\u4eab+\u83f2\u65af\u66fc\u9505\u7089<\/div><div class=\"price\">89,304<small> \u5143\uff08\u6298\u540e\u521d\u6295\uff09<\/small><\/div><\/div>\n        <div class=\"qb\">\n          <div class=\"qrow\"><span>\u8212\u4eab180\u4e3b\u673a\uff088\u6298\uff09<\/span><b>12,920<\/b><\/div>\n          <div class=\"qrow\"><span>\u8212\u4eab\u5185\u673a\u00d76\uff08\u542b\u5b89\u88c5\uff09<\/span><b>24,642<\/b><\/div>\n          <div class=\"qrow\"><span>\u83f2\u65af\u66fcB1JG25\uff08\u542b\u5b89\u88c5\uff09<\/span><b>14,197<\/b><\/div>\n          <div class=\"qrow\"><span>\u5929\u51c0\u65b0\u98ce350\uff08\u542b\u5b89\u88c5\uff09<\/span><b>14,275<\/b><\/div>\n          <div class=\"qrow\"><span>\u5730\u6696130\u33a1\uff08179\u963b\u6c27\uff09<\/span><b>23,270<\/b><\/div>\n          <div class=\"rec\" style=\"background:var(--muted)\">\u6210\u719f\u7a33\u5b9a \u00b7 \u5c45\u4e2d<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <h3 style=\"color:var(--navy-d);margin:28px 0 8px\">\u65b9\u6848\u4e8c \u00b7 \u6c34\u5885\u9002\u98ce\u673a\u76d8\u7ba1\u9010\u53f0\u6838\u4ef7\uff08\u96f6\u8d8a\u7cfb\u5217 DBT\/P \u00b7 \u96f6\u552e\u4ef7\u4e0d\u6253\u6298\uff09<\/h3>\n    <p class=\"fhint\">\u516d\u53f0\u98ce\u76d8\u89c4\u683c\u5404\u4e0d\u76f8\u540c\uff0c\u4e0d\u80fd\u6309\u5747\u4ef7\u4f30\u7b97\u3002\u4ee5\u4e0b\u4e3a\u9010\u53f0\u6309\u578b\u53f7\u67e5\u5f97\u7684\u96f6\u552e\u4ef7\uff0c\u53ef\u5bf9\u7167\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff08page_id=662\uff09\u9644\u5f55\u4e8c\u00b72.3 \u6c34\u5885\u9002\u98ce\u673a\u76d8\u7ba1\u9010\u6761\u590d\u6838\u3002<\/p>\n    <table class=\"tbl\">\n      <thead><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u578b\u53f7\uff08\u96f6\u8d8a\u7cfb\u5217\uff09<\/th><th>\u5236\u51b7\u91cf<\/th><th>\u4ef7\u683c\u7c7b\u578b<\/th><th>\u96f6\u552e\u4ef7<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"pl\">\u4e00\u697c \u9910\u5385<\/td><td>38.8\u33a1<\/td><td>RFP-136WAR\/DBT12Y(Z)03\/P<\/td><td>8.1kW<\/td><td>\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298<\/td><td><b>4,700<\/b><\/td><\/tr>\n        <tr><td class=\"pl\">\u4e00\u697c \u5ba2\u5385<\/td><td>29.5\u33a1<\/td><td>RFP-102WAR\/DBT12Y(Z)03\/P<\/td><td>6.4kW<\/td><td>\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298<\/td><td><b>3,136<\/b><\/td><\/tr>\n        <tr><td class=\"pl\">\u4e00\u697c \u6b21\u5367<\/td><td>11\u33a1<\/td><td>RFP-34WAR\/DBT12Y(Z)03\/P<\/td><td>2.5kW<\/td><td>\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298<\/td><td><b>2,625<\/b><\/td><\/tr>\n        <tr><td class=\"pl\">\u4e00\u697c \u4e66\u623f<\/td><td>11.4\u33a1<\/td><td>RFP-34WAR\/DBT12Y(Z)03\/P<\/td><td>2.5kW<\/td><td>\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298<\/td><td><b>2,625<\/b><\/td><\/tr>\n        <tr><td class=\"pl\">\u4e8c\u697c \u4e3b\u5367\u8863\u5e3d\u95f4<\/td><td>23.1\u33a1<\/td><td>RFP-85WAR\/DBT12Y(Z)03\/P<\/td><td>5.7kW<\/td><td>\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298<\/td><td><b>3,086<\/b><\/td><\/tr>\n        <tr><td class=\"pl\">\u4e8c\u697c \u6b21\u5367<\/td><td>13\u33a1<\/td><td>RFP-51WAR\/DBT12Y(Z)03\/P<\/td><td>3.45kW<\/td><td>\u96f6\u552e\u4ef7\u00b7\u4e0d\u6253\u6298<\/td><td><b>2,752<\/b><\/td><\/tr>\n        <tr><td class=\"pl\"><b>\u516d\u53f0\u5408\u8ba1<\/b><\/td><td>126.8\u33a1<\/td><td colspan=\"3\"><b>4,700\uff0b3,136\uff0b2,625\uff0b2,625\uff0b3,086\uff0b2,752<\/b><\/td><td class=\"hi\"><b>18,924<\/b><\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"note\" style=\"margin-top:12px\">\n      <b>\u6838\u4ef7\u8bf4\u660e<\/b>\uff1a\u6c34\u5885\u9002\u98ce\u673a\u76d8\u7ba1\u5728\u4ef7\u683c\u5e93\u4e2d\u5206 AC\u3001\u7b80\u7ea6DC\u3001\u96f6\u8d8a \u4e09\u4e2a\u6863\u4f4d\uff0c\u540c\u4e00\u89c4\u683c\u4ef7\u5dee\u53ef\u8fbe\u4e09\u500d\uff08\u4ee5136\u578b\u4e3a\u4f8b\uff1aAC 1,835\u5143 \/ \u7b80\u7ea6DC 3,951\u5143 \/ \u96f6\u8d8a 4,700\u5143\uff09\u3002\u672c\u65b9\u6848\u6309\u5ba2\u6237\u6307\u5b9a\u7684 <b>DBT\/P \u96f6\u8d8a\u7cfb\u5217<\/b> \u9010\u53f0\u53d6\u4ef7\uff0c\u5168\u90e8\u4e3a\u96f6\u552e\u4ef7\u3001\u6309\u89c4\u5219\u4e0d\u53c2\u4e0e\u6298\u6263\u3002<br>\n      <b>\u4e0e\u6c1f\u673a\u53e3\u5f84\u7684\u5dee\u5f02<\/b>\uff1a\u65b9\u6848\u4e00\/\u65b9\u6848\u4e09\u7684\u5185\u673a\u62a5\u4ef7\u4e3a\u300c\u542b\u5b89\u88c5\u300d\uff0c\u800c\u6c34\u5885\u9002\u98ce\u76d8\u4e3a\u7eaf\u8bbe\u5907\u96f6\u552e\u4ef7\uff0c\u5b89\u88c5\u53e6\u6309\uff08\u5185\u673a6\u53f0\uff0b\u4e3b\u673a1\u53f0\uff09\u00d73,200\u5143\/\u53f0\u00d78\u6298\uff1d17,920\u5143\u5355\u72ec\u8ba1\u53d6\uff0c\u4e24\u8005\u5408\u8ba1\u540e\u65b9\u53ef\u4e0e\u6c1f\u673a\u65b9\u6848\u6a2a\u5411\u6bd4\u8f83\uff0c\u4e0d\u5b58\u5728\u6f0f\u9879\u6216\u91cd\u590d\u8ba1\u8d39\u3002\n    <\/div>\n\n    <h3 style=\"color:var(--navy-d);margin:28px 0 8px\">\u516d\u7ef4\u5ea6\u5bf9\u6bd4\uff08\u56fa\u5b9a\u987a\u5e8f\uff1a\u521d\u6295\u8d44 \u00b7 \u8fd0\u884c\u8d39 \u00b7 \u8212\u9002\u5ea6 \u00b7 \u7a33\u5b9a\u6027 \u00b7 \u7ef4\u62a4\u8d39 \u00b7 \u5bff\u547d\uff09<\/h3>\n    <p class=\"fhint\">\u6b63\u9762\u4e3a\u4e09\u65b9\u6848\u6570\u636e\u5bf9\u6bd4\uff0c\u7ffb\u8f6c\u80cc\u9762\u4e3a\u8be5\u7ef4\u5ea6\u7684\u5224\u65ad\u4f9d\u636e\u4e0e\u7ed3\u8bba\u3002<\/p>\n    <div class=\"dflip\">\n\n      <div class=\"dcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face df\">\n          <div class=\"dno\">1<\/div><h4>\u521d\u6295\u8d44<\/h4>\n          <div class=\"dbars\">\n            <div class=\"dbrow bad\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<\/span><b>106,853 \u5143<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n            <div class=\"dbrow\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<\/span><b>104,499 \u5143<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:98%\"><\/i><\/div><\/div>\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/span><b>89,304 \u5143<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:84%\"><\/i><\/div><\/div>\n          <\/div>\n          <div class=\"dlegend\">\u67f1\u957f\uff1d\u91d1\u989d\u9ad8\u4f4e \u00b7 \u7eff\u8272\u4e3a\u8be5\u7ef4\u5ea6\u80dc\u51fa\u65b9\uff08\u8d8a\u4f4e\u8d8a\u4f18\uff09<\/div>\n        <\/div>\n        <div class=\"face db\"><h4>\u5224\u65ad\u4f9d\u636e<\/h4>\n          <p>\u4e09\u65b9\u6848\u5185\u673a\u51b7\u91cf\u4e00\u81f4\uff0c\u5dee\u5f02\u5168\u5728\u4e3b\u673a\u7cfb\u7edf\u4e0e\u4ecb\u8d28\u3002\u65b9\u6848\u4e00\u591a\u51fa160\u6c34\u6a21\u5757\u4e0e\u96c6\u63a7\u5c4f\uff08\u4e94\u6052\u4ee3\u4ef7\uff09\uff1b\u65b9\u6848\u4e8c\u4e3b\u673a\u4e0e\u96f6\u8d8a\u98ce\u76d8\u5747\u4e3a\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\u3001\u4e14\u6c34\u7cfb\u7edf\u5b89\u88c5\u63097\u53f0\u5355\u72ec\u8ba1\u53d6\uff0c\u521d\u6295\u4e0e\u65b9\u6848\u4e00\u4ec5\u5dee2,354\u5143\uff1b\u65b9\u6848\u4e09\u8212\u4eab\u4e3b\u673a8\u6298\u6700\u4f4e\uff0c\u4f46\u9700\u53e6\u8d2d\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u3002<\/p>\n          <div class=\"dw\">\u7ed3\u8bba\uff1a\u65b9\u6848\u4e09\u521d\u6295\u6700\u4f4e\uff1b\u4e24\u4e2a\u4e8c\u8054\u4f9b\u521d\u6295\u57fa\u672c\u6301\u5e73\uff0c\u6781\u5dee\u7ea617,549\u5143<\/div>\n        <\/div>\n      <\/div><\/div>\n\n      <div class=\"dcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face df\">\n          <div class=\"dno\">2<\/div><h4>\u8fd0\u884c\u8d39\uff08\u5e74\u00b7\u4f30\u7b97\uff09<\/h4>\n          <div class=\"dbars\">\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<\/span><b>\u7ea6 3,560 \u5143\/\u5e74<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:80%\"><\/i><\/div><\/div>\n            <div class=\"dbrow\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<\/span><b>\u7ea6 3,780 \u5143\/\u5e74<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:85%\"><\/i><\/div><\/div>\n            <div class=\"dbrow bad\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/span><b>\u7ea6 4,470 \u5143\/\u5e74<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n          <\/div>\n          <div class=\"dlegend\">\u91c7\u6696\u5b63110\u5929\uff0b\u5236\u51b7\u5b6390\u5929\uff0b\u65b0\u98ce\u5168\u5e74365\u5929 \u00b7 \u7eff\u8272\u4e3a\u8be5\u7ef4\u5ea6\u80dc\u51fa\u65b9\uff08\u8d8a\u4f4e\u8d8a\u4f18\uff09<\/div>\n        <\/div>\n        <div class=\"face db\"><h4>\u5224\u65ad\u4f9d\u636e<\/h4>\n          <p><b>\u91c7\u6696\u4fa7\u4e24\u4e2a\u4e8c\u8054\u4f9b\u5b8c\u5168\u76f8\u540c<\/b>\uff1a\u65b9\u6848\u4e00\u4e0e\u65b9\u6848\u4e8c\u90fd\u662f\u70ed\u6cf5\u5236\u53d6\u70ed\u6c34\u9001\u5165\u5730\u6696\uff0c\u70ed\u6e90\u4e0e\u51fa\u6c34\u6e29\u5ea6\u4e00\u81f4\uff0c\u91c7\u6696\u5b63\u5404\u7ea62,570\u5143\uff0c\u4e0d\u5b58\u5728\u5dee\u5f02\uff1b\u65b9\u6848\u4e09\u5730\u6696\u70e7\u6c14\uff0c\u51b7\u51dd\u7089\u5373\u4f7f\u630998%\u5b63\u8282\u6548\u7387\u6298\u7b97\u4ecd\u7ea63,440\u5143\uff0c\u662f\u4e09\u65b9\u6848\u4e2d\u91c7\u6696\u8d39\u6700\u9ad8\u7684\u3002<b>\u5dee\u5f02\u51fa\u5728\u5236\u51b7\u4fa7<\/b>\uff1a\u65b9\u6848\u4e8c\u4e3a\u5168\u6c34\u7cfb\u7edf\uff0c\u4e3b\u673a\u5236\u51b7\u51bb\u6c34\u540e\u7ecf\u672b\u7aef\u4e8c\u6b21\u6362\u70ed\u3001\u4e14\u9700\u5faa\u73af\u6c34\u6cf5\u5e38\u5e74\u8fd0\u884c\uff0c\u5236\u51b7\u5b63\u7ea6690\u5143\uff0c\u9ad8\u4e8e\u65b9\u6848\u4e00\u6c1f\u4fa7\u76f4\u81a8\u7684470\u5143\u3002<\/p>\n          <div class=\"dw\">\u7ed3\u8bba\uff1a\u65b9\u6848\u4e09\u5e74\u8fd0\u884c\u8d39\u6700\u9ad8\uff0c20\u5e74\u5dee\u7ea618,200\u5143<\/div>\n        <\/div>\n      <\/div><\/div>\n\n      <div class=\"dcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face df\">\n          <div class=\"dno\">3<\/div><h4>\u8212\u9002\u5ea6<\/h4>\n          <div class=\"dbars\">\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<\/span><b>5\/5 \u6e29\u6e7f\u53cc\u63a7<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n            <div class=\"dbrow\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<\/span><b>4.5\/5 \u51fa\u98ce\u67d4\u548c<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:90%\"><\/i><\/div><\/div>\n            <div class=\"dbrow\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/span><b>4\/5 \u6c1f\u673a\uff0b\u9505\u7089<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:80%\"><\/i><\/div><\/div>\n          <\/div>\n          <div class=\"dlegend\">\u67f1\u957f\uff1d\u8bc4\u5206\u9ad8\u4f4e \u00b7 \u7eff\u8272\u4e3a\u8be5\u7ef4\u5ea6\u80dc\u51fa\u65b9\uff08\u8d8a\u9ad8\u8d8a\u4f18\uff09<\/div>\n        <\/div>\n        <div class=\"face db\"><h4>\u5224\u65ad\u4f9d\u636e<\/h4>\n          <p>\u65b9\u6848\u4e00\u4e09\u7ba1\u5236\u53ef\u72ec\u7acb\u9664\u6e7f\u518d\u70ed\uff0c\u662f\u4e09\u65b9\u6848\u4e2d\u552f\u4e00\u80fd\u505a\u5230\u771f\u6b63\u201c\u6052\u6e7f\u201d\u7684\u914d\u7f6e\uff0c\u53e0\u52a0PE\u51c0\u5316\u4e0e\u96c6\u63a7\u5c4f\u5f62\u6210\u5b8c\u6574\u4e94\u6052\uff1b\u65b9\u6848\u4e8c\u6c34\u7cfb\u7edf\u51fa\u98ce\u67d4\u548c\u4f46\u65e0\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\uff1b\u65b9\u6848\u4e09\u51b7\u6696\u4e24\u5957\u7cfb\u7edf\u5404\u81ea\u4e3a\u653f\uff0c\u65e0\u7edf\u4e00\u96c6\u63a7\u3002<\/p>\n          <div class=\"dw\">\u7ed3\u8bba\uff1a\u5ba2\u6237\u8981\u4e94\u6052\uff0c\u53ea\u6709\u65b9\u6848\u4e00\u5b8c\u6574\u6210\u7acb<\/div>\n        <\/div>\n      <\/div><\/div>\n\n      <div class=\"dcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face df\">\n          <div class=\"dno\">4<\/div><h4>\u7a33\u5b9a\u6027<\/h4>\n          <div class=\"dbars\">\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<\/span><b>5\/5 \u6545\u969c\u70b9\u5c11<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n            <div class=\"dbrow bad\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<\/span><b>3\/5 \u90e8\u4ef6\u8f83\u591a<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:60%\"><\/i><\/div><\/div>\n            <div class=\"dbrow\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/span><b>4\/5 \u6280\u672f\u6210\u719f<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:80%\"><\/i><\/div><\/div>\n          <\/div>\n          <div class=\"dlegend\">\u67f1\u957f\uff1d\u8bc4\u5206\u9ad8\u4f4e \u00b7 \u7eff\u8272\u4e3a\u8be5\u7ef4\u5ea6\u80dc\u51fa\u65b9\uff08\u8d8a\u9ad8\u8d8a\u4f18\uff09<\/div>\n        <\/div>\n        <div class=\"face db\"><h4>\u5224\u65ad\u4f9d\u636e<\/h4>\n          <p>\u65b9\u6848\u4e00\u7a7a\u8c03\u4fa7\u8d70\u6c1f\u65e0\u6c34\u6cf5\u677f\u6362\uff0c\u9690\u853d\u5de5\u7a0b\u6f0f\u6c34\u98ce\u9669\u6700\u4f4e\uff1b\u65b9\u6848\u4e8c\u589e\u52a0\u6c34\u6cf5\u3001\u677f\u6362\u3001\u8865\u6c34\u9600\u3001\u81a8\u80c0\u7f50\u7b49\u90e8\u4ef6\uff0c\u6545\u969c\u70b9\u968f\u4e4b\u589e\u52a0\uff1b\u65b9\u6848\u4e09\u6c1f\u673a\u672c\u8eab\u6210\u719f\uff0c\u4f46\u9505\u7089\u5c5e\u72ec\u7acb\u8bbe\u5907\uff0c\u9700\u5355\u72ec\u7ef4\u4fdd\u3002<\/p>\n          <div class=\"dw\">\u7ed3\u8bba\uff1a\u5ba2\u6237\u660e\u786e\u8981\u201c\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\u201d\uff0c\u65b9\u6848\u4e00\u6700\u5339\u914d<\/div>\n        <\/div>\n      <\/div><\/div>\n\n      <div class=\"dcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face df\">\n          <div class=\"dno\">5<\/div><h4>\u7ef4\u62a4\u8d39\uff08\u5e74\u00b7\u4f30\u7b97\uff09<\/h4>\n          <div class=\"dbars\">\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<\/span><b>\u7ea6 600 \u5143\/\u5e74<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:55%\"><\/i><\/div><\/div>\n            <div class=\"dbrow bad\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<\/span><b>\u7ea6 1,100 \u5143\/\u5e74<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n            <div class=\"dbrow\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/span><b>\u7ea6 900 \u5143\/\u5e74<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:82%\"><\/i><\/div><\/div>\n          <\/div>\n          <div class=\"dlegend\">\u4e09\u65b9\u6848\u5747\u542b\u65b0\u98ce\u6ee4\u7f51\u7ea6400\u5143\/\u5e74 \u00b7 \u7eff\u8272\u4e3a\u8be5\u7ef4\u5ea6\u80dc\u51fa\u65b9\uff08\u8d8a\u4f4e\u8d8a\u4f18\uff09<\/div>\n        <\/div>\n        <div class=\"face db\"><h4>\u5224\u65ad\u4f9d\u636e<\/h4>\n          <p>\u4e09\u65b9\u6848\u5171\u540c\u9879\u4e3a\u65b0\u98ce\u6ee4\u7f51\uff08\u521d\u6548\u5b63\u6e05\u6d17\uff0b\u9ad8\u6548\u5e74\u66f4\u6362\uff09\u7ea6400\u5143\u3002\u5dee\u989d\u6765\u81ea\u7cfb\u7edf\u672c\u8eab\uff1a\u65b9\u6848\u4e00\u6c1f\u4fa7\u65e0\u6c34\u6cf5\u677f\u6362\u3001\u6c34\u4fa7\u4ec5\u4e00\u8def\u5730\u6696\uff0c\u5e74\u68c0\u7ea6200\u5143\uff1b<b>\u65b9\u6848\u4e8c\u4e3a\u5168\u6c34\u7cfb\u7edf\uff0c\u6c34\u8d28\u68c0\u6d4b\u3001\u8865\u6c34\u4e0e\u9664\u6c61\u5668\u6e05\u6d17\u3001\u6c34\u6cf5\u4e0e\u677f\u6362\u68c0\u67e5\u3001\u51ac\u5b63\u9632\u51bb\u9879\u76ee\u6700\u591a\uff0c\u7ea6700\u5143\uff0c\u662f\u4e09\u65b9\u6848\u7ef4\u62a4\u6210\u672c\u6700\u9ad8\u7684<\/b>\uff1b\u65b9\u6848\u4e09\u9700\u627f\u62c5\u51b7\u51dd\u7089\u5f3a\u5236\u5e74\u68c0\u4e0e\u6362\u70ed\u5668\u3001\u71c3\u70e7\u5668\u6e05\u6d17\u7ea6500\u5143\u3002<\/p>\n          <div class=\"dw\">\u7ed3\u8bba\uff1a\u6c34\u673a\u7ef4\u62a4\u6700\u9ad8\uff0c20\u5e74\u6bd4\u65b9\u6848\u4e00\u591a\u7ea610,000\u5143<\/div>\n        <\/div>\n      <\/div><\/div>\n\n      <div class=\"dcard\" tabindex=\"0\"><div class=\"inner\">\n        <div class=\"face df\">\n          <div class=\"dno\">6<\/div><h4>\u5bff\u547d\u4e0e\u66f4\u6362<\/h4>\n          <div class=\"dbars\">\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<\/span><b>20\u5e74 \u514d\u4e8c\u6b21\u8d2d\u7f6e<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n            <div class=\"dbrow win\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<\/span><b>20\u5e74 \u514d\u4e8c\u6b21\u8d2d\u7f6e<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:100%\"><\/i><\/div><\/div>\n            <div class=\"dbrow bad\"><div class=\"dbtop\"><span>\u65b9\u6848\u4e09 \u8212\u4eab+\u83f2\u65af\u66fc<\/span><b>\u9505\u708910\u5e74 \u9700\u63621\u6b21<\/b><\/div><div class=\"dbtrack\"><i class=\"dbfill\" style=\"width:50%\"><\/i><\/div><\/div>\n          <\/div>\n          <div class=\"dlegend\">\u67f1\u957f\uff1d\u5468\u671f\u5185\u514d\u66f4\u6362\u5e74\u9650 \u00b7 \u7eff\u8272\u4e3a\u8be5\u7ef4\u5ea6\u80dc\u51fa\u65b9\uff08\u8d8a\u957f\u8d8a\u4f18\uff09<\/div>\n        <\/div>\n        <div class=\"face db\"><h4>\u5224\u65ad\u4f9d\u636e<\/h4>\n          <p><b>\u4e24\u4e2a\u4e8c\u8054\u4f9b\u572820\u5e74\u5468\u671f\u5185\u5747\u4e0d\u9700\u8981\u4e8c\u6b21\u8d2d\u7f6e<\/b>\uff1a\u65e5\u7acb\u70ed\u6cf5\u4e3b\u673a\u630920\u5e74\u7cfb\u7edf\u5bff\u547d\u8bbe\u8ba1\uff0c\u65b9\u6848\u4e8c\u7684\u6c34\u6cf5\u3001\u677f\u6362\u5c5e\u53ef\u7ef4\u4fee\u66f4\u6362\u7684\u8f85\u4ef6\uff0c\u5176\u6210\u672c\u5df2\u644a\u5165\u7ef4\u62a4\u8d39\u800c\u975e\u66ff\u6362\u6210\u672c\u3002<b>\u5dee\u5f02\u5728\u65b9\u6848\u4e09<\/b>\uff1a\u71c3\u6c14\u51b7\u51dd\u7089\u7684\u6362\u70ed\u5668\u4e0e\u71c3\u70e7\u7ec4\u4ef6\u5bff\u547d\u901a\u5e3810\uff5e12\u5e74\uff0c20\u5e74\u5468\u671f\u5185\u9700\u6574\u673a\u66f4\u63621\u6b21\uff0c\u6309\u5f53\u524d\u5355\u4ef713,597\u5143\u8ba1\u5165\uff08\u672a\u8ba1\u901a\u80c0\uff0c\u5b9e\u9645\u66f4\u6362\u65f6\u4ef7\u683c\u53ef\u80fd\u66f4\u9ad8\uff09\u3002<\/p>\n          <div class=\"dw\">\u7ed3\u8bba\uff1a\u4e8c\u8054\u4f9b\u66f4\u6362\u6210\u672c\u4e3a0\uff0c\u51b7\u51dd\u7089\u662f\u552f\u4e00\u9700\u4e8c\u6b21\u8d2d\u7f6e\u7684\u8bbe\u5907<\/div>\n        <\/div>\n      <\/div><\/div>\n\n    <\/div>\n\n    <h3 style=\"color:var(--navy-d);margin:28px 0 8px\">\u5e74\u8fd0\u884c\u8d39\u6d4b\u7b97\u660e\u7ec6\uff08\u53e3\u5f84\u516c\u5f00 \u00b7 \u53ef\u9010\u9879\u9a8c\u7b97\uff09<\/h3>\n    <p class=\"fhint\">\u8fd0\u884c\u8d39\u4e0d\u662f\u62cd\u8111\u888b\u7684\u4e00\u4e2a\u6570\u3002\u4ee5\u4e0b\u628a\u4e09\u65b9\u6848\u7684\u7528\u80fd\u62c6\u6210\u91c7\u6696\u3001\u5236\u51b7\u3001\u65b0\u98ce\u4e09\u6bb5\uff0c\u9010\u6bb5\u6807\u660e\u8fd0\u884c\u5929\u6570\u4e0e\u8ba1\u4ef7\u53c2\u6570\uff0c\u4efb\u4f55\u4e00\u9879\u90fd\u53ef\u4ee5\u81ea\u5df1\u91cd\u7b97\u3002<\/p>\n    <table class=\"tbl\">\n      <thead><tr><th>\u7528\u80fd\u9879<\/th><th>\u8fd0\u884c\u5468\u671f<\/th><th>\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<br>\u5929\u6c1f\u5730\u6c34<\/th><th>\u65b9\u6848\u4e8c \u6c34\u5885\u9002<br>\u5929\u6c34\u5730\u6c34<\/th><th>\u65b9\u6848\u4e09 \u8212\u4eab<br>\uff0b\u83f2\u65af\u66fc\u51b7\u51dd\u7089<\/th><\/tr><\/thead>\n      <tbody>\n        <tr>\n          <td class=\"pl\">\u91c7\u6696\uff08\u5730\u6696130\u33a1\uff09<\/td>\n          <td>\u91c7\u6696\u5b63 <b>\u7ea6110\u5929<\/b><br><span style=\"color:var(--muted);font-size:12.5px\">11\u6708\u4e0b\u65ec\uff5e\u6b21\u5e743\u6708\u4e0a\u65ec<\/span><\/td>\n          <td>2,570 \u5143<br><span style=\"color:var(--muted);font-size:12.5px\">\u70ed\u6cf5\u5236\u70ed\u6c34<\/span><\/td>\n          <td>2,570 \u5143<br><span style=\"color:var(--muted);font-size:12.5px\">\u70ed\u6cf5\u5236\u70ed\u6c34\uff08\u540c\u4e0a\uff09<\/span><\/td>\n          <td class=\"mid\">3,440 \u5143<br><span style=\"color:var(--muted);font-size:12.5px\">\u71c3\u6c14\u51b7\u51dd\u7089<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td class=\"pl\">\u5236\u51b7\uff08\u7a7a\u8c03126.8\u33a1\uff09<\/td>\n          <td>\u5236\u51b7\u5b63 <b>\u7ea690\u5929<\/b><br><span style=\"color:var(--muted);font-size:12.5px\">6\u6708\u4e2d\u65ec\uff5e9\u6708\u4e0a\u65ec<\/span><\/td>\n          <td class=\"hi\">470 \u5143<br><span style=\"color:var(--muted);font-size:12.5px\">\u6c1f\u4fa7\u76f4\u81a8<\/span><\/td>\n          <td class=\"mid\">690 \u5143<br><span style=\"color:var(--muted);font-size:12.5px\">\u6c34\u7cfb\u7edf\uff0b\u5faa\u73af\u6cf5<\/span><\/td>\n          <td>510 \u5143<br><span style=\"color:var(--muted);font-size:12.5px\">\u6c1f\u4fa7\u76f4\u81a8<\/span><\/td>\n        <\/tr>\n        <tr>\n          <td class=\"pl\">\u65b0\u98ce\uff08\u5929\u51c0350\uff09<\/td>\n          <td>\u5168\u5e74 <b>365\u5929<\/b><br><span style=\"color:var(--muted);font-size:12.5px\">\u65e5\u5747\u8fd0\u884c\u7ea620\u5c0f\u65f6<\/span><\/td>\n          <td>520 \u5143<\/td><td>520 \u5143<\/td><td>520 \u5143<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"pl\"><b>\u5e74\u8fd0\u884c\u8d39\u5408\u8ba1<\/b><\/td>\n          <td><b>\u91c7\u6696110\u5929\uff0b\u5236\u51b790\u5929\uff0b\u65b0\u98ce\u5168\u5e74<\/b><\/td>\n          <td class=\"hi\"><b>\u7ea6 3,560 \u5143\/\u5e74<\/b><\/td>\n          <td><b>\u7ea6 3,780 \u5143\/\u5e74<\/b><\/td>\n          <td class=\"mid\"><b>\u7ea6 4,470 \u5143\/\u5e74<\/b><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"note\" style=\"margin-top:14px\">\n      <b>\u8ba1\u4ef7\u53c2\u6570\uff08\u6210\u90fd\u53e3\u5f84\uff09<\/b>\uff1a\u5c45\u6c11\u7535\u4ef7 0.60 \u5143\/kWh\uff08\u9636\u68af\u4e8c\u6863\u7efc\u5408\uff09\uff1b\u6c11\u7528\u5929\u7136\u6c14 2.70 \u5143\/m\u00b3\uff08\u9636\u68af\u4e8c\/\u4e09\u6863\u7efc\u5408\uff0c\u4f4e\u4f4d\u70ed\u503c 9.87 kWh\/m\u00b3\uff09\u3002<br>\n      <b>\u91c7\u6696\u7b97\u6cd5<\/b>\uff1a\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377 70 W\/\u33a1 \u00d7 130\u33a1 \uff1d 9.1 kW\uff0c\u65e5\u7b49\u6548\u6ee1\u8d1f\u8377 12 \u5c0f\u65f6\uff0c\u91c7\u6696\u5b63\u603b\u70ed\u91cf \u2248 12,012 kWh\u3002\u65b9\u6848\u4e00\u3001\u65b9\u6848\u4e8c\u5747\u4e3a\u70ed\u6cf5\u5236\u53d6\u70ed\u6c34\u9001\u5730\u6696\uff0c\u4f4e\u6e29\u5de5\u51b5 COP \u53d6 2.8\uff08\u5df2\u8ba1\u5165\u6210\u90fd\u6e7f\u51b7\u5316\u971c\u635f\u5931\uff09\uff0c\u8017\u7535 4,290 kWh \u00d7 0.60 \uff1d 2,574 \u5143\u2014\u2014<b>\u4e24\u4e2a\u4e8c\u8054\u4f9b\u7684\u91c7\u6696\u4fa7\u70ed\u6e90\u4e0e\u51fa\u6c34\u6e29\u5ea6\u5b8c\u5168\u4e00\u81f4\uff0c\u91c7\u6696\u8d39\u6ca1\u6709\u5dee\u5f02<\/b>\u3002\u65b9\u6848\u4e09\u51b7\u51dd\u7089\u6309\u5b63\u8282\u6548\u7387 98% \u6298\u7b97\u8017\u6c14 1,242 m\u00b3 \u00d7 2.70 \uff1d 3,353 \u5143\uff0c\u53e6\u52a0\u9505\u7089\u5faa\u73af\u6cf5\u4e0e\u98ce\u673a\u81ea\u8017\u7535\u7ea6 87 \u5143\u3002<br>\n      <b>\u5236\u51b7\u7b97\u6cd5<\/b>\uff1a\u51b7\u8d1f\u8377 110 W\/\u33a1 \u00d7 126.8\u33a1 \uff1d 13.9 kW\uff0c\u65e5\u7b49\u6548\u6ee1\u8d1f\u8377 5 \u5c0f\u65f6\u3001\u540c\u5f00\u7387 45%\uff0c\u5236\u51b7\u5b63\u603b\u51b7\u91cf \u2248 2,817 kWh\u3002\u65b9\u6848\u4e00\u7efc\u5408 EER 3.6\u3001\u65b9\u6848\u4e09 3.3\uff1b<b>\u65b9\u6848\u4e8c\u4e3a\u6c34\u7cfb\u7edf\uff0c\u51b7\u51bb\u6c34\u7ecf\u672b\u7aef\u4e8c\u6b21\u6362\u70ed\u5bfc\u81f4\u84b8\u53d1\u6e29\u5ea6\u66f4\u4f4e\uff0c\u4e3b\u673a EER \u964d\u81f3\u7ea6 2.90\uff0c\u53e6\u52a0\u5faa\u73af\u6c34\u6cf5 250W\u00d78h\u00d790\u5929 \u2248 108 \u5143<\/b>\uff0c\u8fd9\u662f\u65b9\u6848\u4e8c\u5236\u51b7\u8d39\u9ad8\u4e8e\u4e24\u4e2a\u6c1f\u4fa7\u65b9\u6848\u7684\u539f\u56e0\u3002<br>\n      <b>\u8bf4\u660e<\/b>\uff1a\u4ee5\u4e0a\u4e3a\u6309\u6210\u90fd\u5178\u578b\u6c14\u5019\u4e0e\u672c\u6237\u578b\u8d1f\u8377\u63a8\u7b97\u7684\u4f30\u7b97\u503c\uff0c\u5b9e\u9645\u652f\u51fa\u968f\u4f5c\u606f\u3001\u8bbe\u5b9a\u6e29\u5ea6\u4e0e\u9636\u68af\u7535\u4ef7\u6863\u4f4d\u6d6e\u52a8\uff0c\u901a\u5e38\u5728 \u00b115% \u533a\u95f4\u5185\u3002\u4e09\u65b9\u6848\u91c7\u7528\u5b8c\u5168\u76f8\u540c\u7684\u53c2\u6570\u53e3\u5f84\uff0c\u6a2a\u5411\u5bf9\u6bd4\u6709\u6548\u3002\n    <\/div>\n\n    <h3 style=\"color:var(--navy-d);margin:28px 0 8px\">20\u5e74\u603b\u8d26\uff08\u56fa\u5b9a\u516c\u5f0f\uff1aC\u2080\u521d\u6295 + R\u00d720\u5e74\u8fd0\u884c + M\u00d720\u5e74\u7ef4\u62a4 + \u66f4\u6362\uff09<\/h3>\n    <p class=\"fhint\">\u6b63\u9762\u4e3a\u56db\u53d8\u91cf\u5806\u53e0\u67f1\u72b6\u56fe\uff0c\u70b9\u51fb\u300c\u7ffb\u8f6c\u67e5\u770b\u516c\u5f0f\u660e\u7ec6\u300d\u53ef\u6838\u5bf9\u6bcf\u4e00\u9879\u6570\u5b57\u7684\u6765\u6e90\u4e0e\u7b97\u5f0f\u3002<\/p>\n    <div class=\"lwrap\" id=\"lifeFlip\"><div class=\"linner\">\n      <div class=\"lface lfront\">\n        <div class=\"lhead\">\n          <h4>20\u5e74\u603b\u6301\u6709\u6210\u672c\u6784\u6210\uff08C\u2080\u521d\u6295 \/ R\u8fd0\u884c\u00d720 \/ M\u7ef4\u62a4\u00d720 \/ \u66f4\u6362\uff09<\/h4>\n          <button type=\"button\" class=\"lflipbtn\" data-lflip>\u7ffb\u8f6c\u67e5\u770b\u516c\u5f0f\u660e\u7ec6<\/button>\n        <\/div>\n        <div class=\"lm-chart\" id=\"lm20Chart\"><\/div>\n        <div class=\"lmfb\" id=\"lm20Fallback\">\n          <div class=\"fbrow\"><div class=\"fbname\">\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548<br>\u5929\u6c1f\u5730\u6c34\u4e94\u6052<\/div>\n            <div class=\"fbbar\"><i class=\"c0\" style=\"width:50.8%\"><\/i><i class=\"r\" style=\"width:33.9%\"><\/i><i class=\"m\" style=\"width:5.7%\"><\/i><i class=\"x\" style=\"width:0%\"><\/i><\/div>\n            <div class=\"fbtot\">19.01\u4e07<\/div><\/div>\n          <div class=\"fbrow\"><div class=\"fbname\">\u65b9\u6848\u4e8c \u6c34\u5885\u9002<br>\u5929\u6c34\u5730\u6c34<\/div>\n            <div class=\"fbbar\"><i class=\"c0\" style=\"width:49.7%\"><\/i><i class=\"r\" style=\"width:35.9%\"><\/i><i class=\"m\" style=\"width:10.5%\"><\/i><i class=\"x\" style=\"width:0%\"><\/i><\/div>\n            <div class=\"fbtot\">20.21\u4e07<\/div><\/div>\n          <div class=\"fbrow\"><div class=\"fbname\">\u65b9\u6848\u4e09 \u8212\u4eab<br>\uff0b\u83f2\u65af\u66fc\u9505\u7089<\/div>\n            <div class=\"fbbar\"><i class=\"c0\" style=\"width:42.5%\"><\/i><i class=\"r\" style=\"width:42.5%\"><\/i><i class=\"m\" style=\"width:8.5%\"><\/i><i class=\"x\" style=\"width:6.5%\"><\/i><\/div>\n            <div class=\"fbtot\">21.03\u4e07<\/div><\/div>\n          <div class=\"fblg\">\n            <span><em style=\"background:#102740\"><\/em>C\u2080 \u521d\u6295\u8d44<\/span>\n            <span><em style=\"background:#2e5f87\"><\/em>R \u8fd0\u884c\u8d39\u00d720\u5e74<\/span>\n            <span><em style=\"background:#c8a35a\"><\/em>M \u7ef4\u62a4\u8d39\u00d720\u5e74<\/span>\n            <span><em style=\"background:#c0792b\"><\/em>\u66f4\u6362\u6210\u672c<\/span>\n          <\/div>\n        <\/div>\n        <div class=\"dlegend\">\u67f1\u957f\uff1d20\u5e74\u603b\u8d26\uff1b\u5206\u6bb5\u4f9d\u6b21\u4e3a C\u2080\u521d\u6295\u3001R\u8fd0\u884c\u00d720\u5e74\u3001M\u7ef4\u62a4\u00d720\u5e74\u3001\u66f4\u6362\u6210\u672c\uff1b\u4ee5\u65b9\u6848\u4e0921.03\u4e07\u4e3a100%\u57fa\u51c6\u3002\u4e24\u4e2a\u4e8c\u8054\u4f9b\u66f4\u6362\u6210\u672c\u4e3a0\uff0c\u6545\u65e0\u7b2c\u56db\u6bb5\u3002\u8fd0\u884c\u8d39\u4e0e\u7ef4\u62a4\u8d39\u4e3a\u4f30\u7b97\u503c\u3002<\/div>\n      <\/div>\n      <div class=\"lface lback\">\n        <div class=\"lhead\">\n          <h4>\u516c\u5f0f\u660e\u7ec6 \u00b7 \u53ef\u9010\u9879\u9a8c\u7b97<\/h4>\n          <button type=\"button\" class=\"lflipbtn\" data-lflip>\u7ffb\u56de\u56fe\u8868<\/button>\n        <\/div>\n        <div class=\"life\">\n          <div class=\"lcard\">\n            <h4>\u65b9\u6848\u4e00 \u00b7 \u5929\u6c1f\u5730\u6c34\u4e94\u6052<\/h4>\n            <div class=\"total\">\u2248 190,053 \u5143<\/div>\n            <div class=\"formula\">C\u2080 106,853<br>+ R 3,560\u00d720=71,200<br>+ M 600\u00d720=12,000<br>+ \u66f4\u6362 0\uff0820\u5e74\u514d\u4e8c\u6b21\u8d2d\u7f6e\uff09<\/div>\n          <\/div>\n          <div class=\"lcard\">\n            <h4>\u65b9\u6848\u4e8c \u00b7 \u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/h4>\n            <div class=\"total\">\u2248 202,099 \u5143<\/div>\n            <div class=\"formula\">C\u2080 104,499<br>+ R 3,780\u00d720=75,600<br>+ M 1,100\u00d720=22,000<br>+ \u66f4\u6362 0\uff0820\u5e74\u514d\u4e8c\u6b21\u8d2d\u7f6e\uff09<\/div>\n          <\/div>\n          <div class=\"lcard\">\n            <h4>\u65b9\u6848\u4e09 \u00b7 \u8212\u4eab+\u83f2\u65af\u66fc<\/h4>\n            <div class=\"total\">\u2248 210,301 \u5143<\/div>\n            <div class=\"formula\">C\u2080 89,304<br>+ R 4,470\u00d720=89,400<br>+ M 900\u00d720=18,000<br>+ \u66f4\u6362 13,597\uff08\u51b7\u51dd\u7089\u7b2c10\u5e74\u63621\u6b21\uff09<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"dlegend\" style=\"color:rgba(232,238,246,.7);border-top-color:rgba(255,255,255,.18)\">C\u2080\u4e3a\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\u6298\u540e\u771f\u503c\uff1bR\uff1d\u5e74\u8fd0\u884c\u8d39\uff08\u91c7\u6696\u5b63110\u5929\uff0b\u5236\u51b7\u5b6390\u5929\uff0b\u65b0\u98ce\u5168\u5e74365\u5929\uff0c\u6d4b\u7b97\u660e\u7ec6\u89c1\u4e0a\u8868\uff09\uff1bM\uff1d\u5e74\u7ef4\u62a4\u8d39\uff1b\u66f4\u6362\u6210\u672c\u6309\u8bbe\u5907\u5bff\u547d\u5468\u671f\u5185\u4e8c\u6b21\u8d2d\u7f6e\u8ba1\uff0c\u4e24\u4e2a\u4e8c\u8054\u4f9b\u4e3b\u673a\u630920\u5e74\u8bbe\u8ba1\u5bff\u547d\u5747\u4e3a0\uff0c\u51b7\u51dd\u7089\u630910\uff5e12\u5e74\u5bff\u547d\u572820\u5e74\u5185\u66f4\u63621\u6b21\u3002\u672a\u8ba1\u901a\u80c0\u4e0e\u80fd\u6e90\u4ef7\u683c\u4e0a\u6da8\u3002<\/div>\n      <\/div>\n    <\/div><\/div>\n    <h3 style=\"color:var(--navy-d);margin:28px 0 8px\">\u65b9\u6848\u52a3\u52bf\u8bda\u5b9e\u62ab\u9732\uff08\u4e0d\u56de\u907f\uff09<\/h3>\n    <p class=\"fhint\">\u53ea\u8bb2\u4f18\u70b9\u7684\u65b9\u6848\u4e66\u4e0d\u503c\u5f97\u4fe1\u3002\u4ee5\u4e0b\u662f\u6bcf\u4e2a\u65b9\u6848\u5ba2\u89c2\u5b58\u5728\u7684\u77ed\u677f\uff0c\u8bf7\u4e00\u5e76\u7eb3\u5165\u51b3\u7b56\u3002<\/p>\n    <div class=\"cons\">\n      <div class=\"concard\">\n        <h4>\u65b9\u6848\u4e00 \u00b7 \u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34<\/h4>\n        <ul>\n          <li>\u521d\u6295\u6700\u9ad8\uff08106,853\u5143\uff09\uff0c\u6bd4\u65b9\u6848\u4e09\u591a\u51fa17,549\u5143\uff0c\u9884\u7b97\u654f\u611f\u65f6\u538b\u529b\u660e\u663e\u3002<\/li>\n          <li>160\u6c34\u6a21\u5757\u6309\u672c\u5355\u7ea6\u5b9a\u4e0d\u6253\u6298\uff0c\u8fd9\u90e8\u5206\u6210\u672c\u65e0\u6cd5\u901a\u8fc7\u6298\u6263\u538b\u7f29\u3002<\/li>\n          <li>\u4e09\u7ba1\u5236\uff0b\u96c6\u63a7\u5c4f\u5c5e\u7cbe\u5bc6\u7cfb\u7edf\uff0c\u540e\u671f\u52a0\u70b9\u4f4d\u6216\u6539\u9020\u7684\u81ea\u7531\u5ea6\u4f4e\u4e8e\u6c34\u7cfb\u7edf\u3002<\/li>\n          <li>\u7a7a\u8c03\u4fa7\u8d70\u6c1f\uff0c\u51fa\u98ce\u5f3a\u5ea6\u9ad8\u4e8e\u6c34\u7cfb\u7edf\uff0c\u5bf9\u504f\u597d\u201c\u67d4\u548c\u98ce\u611f\u201d\u7684\u4eba\u9700\u9760\u98ce\u53e3\u4e0e\u98ce\u901f\u8bbe\u7f6e\u8865\u507f\u3002<\/li>\n          <li><b>\u51b7\u6696\u5171\u7528\u4e00\u53f0\u4e3b\u673a<\/b>\uff1a\u5236\u51b7\u3001\u91c7\u6696\u3001\u9664\u6e7f\u90fd\u7531\u5c0a\u777f\u5168\u6548180\u627f\u62c5\uff0c\u4e3b\u673a\u4e00\u65e6\u505c\u673a\u5219\u51b7\u6696\u540c\u65f6\u53d7\u5f71\u54cd\uff1b\u65b9\u6848\u4e09\u7684\u9505\u7089\u4e0e\u7a7a\u8c03\u5f7c\u6b64\u72ec\u7acb\uff0c\u5355\u70b9\u6545\u969c\u4e0d\u4f1a\u6ce2\u53ca\u5168\u5c4b\u3002\u8fd9\u662f\u4e8c\u8054\u4f9b\u67b6\u6784\u7684\u56fa\u6709\u53d6\u820d\uff0c\u65b9\u6848\u4e8c\u540c\u6837\u5b58\u5728\u3002<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"concard\">\n        <h4>\u65b9\u6848\u4e8c \u00b7 \u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34<\/h4>\n        <ul>\n          <li><b>\u5e74\u7ef4\u62a4\u8d39\u6700\u9ad8\uff08\u7ea61,100\u5143\uff09<\/b>\uff0c\u6c34\u8d28\u68c0\u6d4b\u3001\u8865\u6c34\u4e0e\u9664\u6c61\u5668\u6e05\u6d17\u3001\u6c34\u6cf5\u4e0e\u677f\u6362\u68c0\u67e5\u3001\u51ac\u5b63\u9632\u51bb\uff0c\u9879\u76ee\u6570\u660e\u663e\u591a\u4e8e\u6c1f\u7cfb\u7edf\u3002<\/li>\n          <li>\u6c34\u6cf5\u3001\u677f\u6362\u3001\u8865\u6c34\u9600\u3001\u81a8\u80c0\u7f50\u7b49\u90e8\u4ef6\u589e\u52a0\uff0c\u9690\u853d\u5de5\u7a0b\u6f0f\u6c34\u98ce\u9669\u9ad8\u4e8e\u65b9\u6848\u4e00\u3002<\/li>\n          <li><b>\u5236\u51b7\u5b63\u8fd0\u884c\u8d39\u9ad8\u4e8e\u4e24\u4e2a\u6c1f\u4fa7\u65b9\u6848<\/b>\uff1a\u51b7\u51bb\u6c34\u7ecf\u672b\u7aef\u4e8c\u6b21\u6362\u70ed\u4f7f\u84b8\u53d1\u6e29\u5ea6\u66f4\u4f4e\u3001\u4e3b\u673a\u80fd\u6548\u4e0b\u964d\uff0c\u518d\u52a0\u5faa\u73af\u6c34\u6cf5\u5e38\u5e74\u8fd0\u884c\uff0c\u5236\u51b7\u5b63\u7ea6690\u5143 vs \u65b9\u6848\u4e00470\u5143\u3002<\/li>\n          <li><b>\u521d\u6295\u5e76\u4e0d\u4fbf\u5b9c<\/b>\uff1a\u4e3b\u673a\u4e0e\u96f6\u8d8a\u98ce\u76d8\u5747\u4e3a\u96f6\u552e\u4ef7\u3001\u6309\u89c4\u5219\u4e0d\u53c2\u4e0e\u6298\u6263\uff0c\u516d\u53f0\u98ce\u76d8\u89c4\u683c\u5404\u5f02\u9010\u53f0\u6838\u4ef7\u5408\u8ba118,924\u5143\uff08136\u578b\u5355\u53f0\u5c31\u89814,700\u5143\uff09\uff0c\u52a0\u4e0a\u63097\u53f0\u8ba1\u53d6\u7684\u6c34\u7cfb\u7edf\u5b89\u88c5\u8d3917,920\u5143\uff0c\u521d\u6295104,499\u5143\uff0c\u4e0e\u65b9\u6848\u4e00\u4ec5\u5dee2,354\u5143\u2014\u2014\u6c34\u673a\u5e76\u4e0d\u6bd4\u5168\u6548\u6c1f\u673a\u7701\u94b1\u3002<\/li>\n          <li><b>20\u5e74\u603b\u8d26202,099\u5143\uff0c\u6bd4\u65b9\u6848\u4e00\u9ad8\u51fa12,046\u5143<\/b>\uff1a\u521d\u6295\u51e0\u4e4e\u6253\u5e73\u7684\u524d\u63d0\u4e0b\uff0c\u6bcf\u5e74\u591a\u51fa\u7684220\u5143\u8fd0\u884c\u8d39\u4e0e500\u5143\u7ef4\u62a4\u8d39\u4f1a\u6301\u7eed\u7d2f\u79ef\uff0c\u65b9\u6848\u4e00\u5728\u7b2c4\u5e74\u5373\u5b8c\u6210\u53cd\u8d85\u3002<\/li>\n          <li>\u672c\u6237130\u33a1\u3001\u540c\u5f00\u7387\u7ea640%\uff5e50%\uff0c\u672a\u89e6\u53ca\u6c34\u673a\u201c\u8bbe\u8ba1\u81ea\u7531\u201d\u771f\u6b63\u5212\u7b97\u7684\u4f53\u91cf\u95e8\u69db\u3002<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"concard\">\n        <h4>\u65b9\u6848\u4e09 \u00b7 \u8212\u4eab\uff0b\u83f2\u65af\u66fc\u9505\u7089<\/h4>\n        <ul>\n          <li>\u51b7\u6696\u4e24\u5957\u7cfb\u7edf\u5404\u81ea\u4e3a\u653f\uff0c\u65e0\u7edf\u4e00\u96c6\u63a7\uff0c<b>\u4e94\u6052\u4e0d\u5b8c\u6574<\/b>\uff08\u65e0\u6e29\u6e7f\u53cc\u63a7\u3001\u65e0\u5168\u5c4b\u8054\u52a8\uff09\u3002<\/li>\n          <li><b>\u91c7\u6696\u8fd0\u884c\u8d39\u4e09\u65b9\u6848\u6700\u9ad8<\/b>\uff1a\u5730\u6696\u70e7\u6c14\uff0c\u91c7\u6696\u5b63\u7ea63,440\u5143\uff0c\u6bd4\u4e24\u4e2a\u70ed\u6cf5\u4e8c\u8054\u4f9b\u76842,570\u5143\u6bcf\u5e74\u591a\u51fa\u7ea6870\u5143\uff0c20\u5e74\u7d2f\u8ba1\u591a\u7ea617,400\u5143\u3002<\/li>\n          <li><b>\u552f\u4e00\u9700\u8981\u4e8c\u6b21\u8d2d\u7f6e\u7684\u65b9\u6848<\/b>\uff1a\u51b7\u51dd\u7089\u6362\u70ed\u5668\u4e0e\u71c3\u70e7\u7ec4\u4ef6\u5bff\u547d\u901a\u5e3810\uff5e12\u5e74\uff0c20\u5e74\u5468\u671f\u5185\u9700\u6574\u673a\u66f4\u63621\u6b21\uff08\u6309\u5f53\u524d\u5355\u4ef7\u8ba113,597\u5143\uff0c\u672a\u8ba1\u901a\u80c0\uff09\uff0c\u4e14\u6bcf\u5e74\u9700\u5f3a\u5236\u5e74\u68c0\u4e0e\u6362\u70ed\u5668\u6e05\u6d17\u3002<\/li>\n          <li>\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u4f1a\u76f4\u63a5\u53cd\u6620\u5728\u91c7\u6696\u5b63\u652f\u51fa\u4e0a\uff0c\u800c\u70ed\u6cf5\u65b9\u6848\u53ea\u968f\u7535\u4ef7\u6d6e\u52a8\uff0c\u6ce2\u52a8\u5e45\u5ea6\u66f4\u5c0f\u3002<\/li>\n          <li><b>20\u5e74\u603b\u8d26\u7ea621.03\u4e07\u4e3a\u4e09\u65b9\u6848\u6700\u9ad8<\/b>\uff0c\u6bd4\u521d\u6295\u6700\u9ad8\u7684\u65b9\u6848\u4e00\u53cd\u800c\u591a\u51fa20,248\u5143\u2014\u2014\u521d\u6295\u7701\u4e0b\u768417,549\u5143\u5728\u7b2c10\u5e74\u66f4\u6362\u51b7\u51dd\u7089\u65f6\u88ab\u4e00\u6b21\u6027\u62b9\u5e73\u5e76\u53cd\u8d85\u3002<\/li>\n          <li>\u4e0e\u5ba2\u6237\u201c\u628a\u5bb6\u505a\u6210\u4e94\u6052\u201d\u7684\u539f\u59cb\u60f3\u6cd5\u5339\u914d\u5ea6\u6700\u4f4e\uff0c\u4ec5\u4f5c\u4e3a\u9884\u7b97\u4f18\u5148\u7684\u7a33\u59a5\u9009\u9879\u3002<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n    <div class=\"note\">\n      <b>\u7ed3\u8bba\u4e00\uff1a\u4e24\u4e2a\u4e8c\u8054\u4f9b\u521d\u6295\u57fa\u672c\u6301\u5e73\uff0c\u4f4620\u5e74\u65b9\u6848\u4e00\u660e\u663e\u66f4\u7701\u3002<\/b>\u7ecf\u9010\u53f0\u6838\u4ef7\u4fee\u6b63\u540e\uff0c\u65b9\u6848\u4e8c\u521d\u6295104,499\u5143\uff0c\u4e0e\u65b9\u6848\u4e00106,853\u5143\u4ec5\u5dee2,354\u5143\u2014\u2014\u6c34\u5885\u9002\u7684\u96f6\u8d8a\u98ce\u76d8\u4e0e\u4e3b\u673a\u90fd\u662f\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\uff0c\u516d\u53f0\u98ce\u76d8\u5c31\u898118,924\u5143\uff0c\u518d\u52a0\u63097\u53f0\u8ba1\u53d6\u768417,920\u5143\u6c34\u7cfb\u7edf\u5b89\u88c5\u8d39\uff0c\u6240\u8c13\u201c\u6c34\u673a\u66f4\u4fbf\u5b9c\u201d\u5728\u672c\u6237\u5e76\u4e0d\u6210\u7acb\u3002\u800c\u5e74\u8fd0\u884c\u8d39\u65b9\u6848\u4e8c\u591a220\u5143\u3001\u5e74\u7ef4\u62a4\u8d39\u591a500\u5143\uff0c\u5408\u8ba1\u6bcf\u5e74\u591a720\u5143\uff0c<b>\u65b9\u6848\u4e00\u5728\u7b2c4\u5e74\u5373\u5b8c\u6210\u53cd\u8d85\uff0c20\u5e74\u603b\u8d26\u4f4e12,046\u5143<\/b>\uff08190,053 \u5bf9 202,099\uff09\u3002<br><br>\n      <b>\u7ed3\u8bba\u4e8c\uff1a\u65b9\u6848\u4e09\u521d\u6295\u6700\u4f4e\uff0c20\u5e74\u603b\u8d26\u5374\u6700\u9ad8\u3002<\/b>210,301\u5143\uff0c\u6bd4\u65b9\u6848\u4e00\u591a\u51fa20,248\u5143\u3002\u539f\u56e0\u6709\u4e8c\uff1a\u5730\u6696\u70e7\u6c14\u4f7f\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u6bd4\u70ed\u6cf5\u4e8c\u8054\u4f9b\u6bcf\u5e74\u591a\u7ea6870\u5143\uff0820\u5e74\u7d2f\u8ba117,400\u5143\uff09\uff1b\u51b7\u51dd\u7089\u5bff\u547d10\uff5e12\u5e74\uff0c20\u5e74\u5185\u5fc5\u987b\u6574\u673a\u66f4\u63621\u6b21\uff0813,597\u5143\uff09\u3002<b>\u521d\u6295\u7701\u4e0b\u768417,549\u5143\uff0c\u5728\u7b2c10\u5e74\u66f4\u6362\u51b7\u51dd\u7089\u7684\u90a3\u4e00\u523b\u88ab\u4e00\u6b21\u6027\u62b9\u5e73\u5e76\u53cd\u8d85\u3002<\/b><br><br>\n      <b>\u7ed3\u8bba\u4e09\uff1a\u987e\u95ee\u5efa\u8bae\u65b9\u6848\u4e00\u3002<\/b>\u4e09\u6761\u7406\u7531\u540c\u65f6\u6210\u7acb\u2014\u2014\u5b83\u662f\u4e09\u65b9\u6848\u4e2d\u552f\u4e00\u5b8c\u6574\u6210\u7acb\u7684\u4e94\u6052\u7cfb\u7edf\uff1b\u6c1f\u4fa7\u65e0\u6c34\u6cf5\u3001\u65e0\u677f\u6362\u3001\u65e0\u4e8c\u6b21\u6362\u70ed\uff0c\u4e0e\u5ba2\u6237\u660e\u786e\u63d0\u51fa\u7684\u201c\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\u201d\u6700\u5339\u914d\uff1b\u4e14\u5728\u521d\u6295\u4ec5\u6bd4\u65b9\u6848\u4e8c\u9ad82,354\u5143\u7684\u524d\u63d0\u4e0b\uff0c20\u5e74\u603b\u8d26\u53cd\u800c\u6700\u4f4e\u3002\u82e5\u5ba2\u6237\u4ecd\u66f4\u770b\u91cd\u6c34\u7cfb\u7edf\u7684\u67d4\u548c\u98ce\u611f\uff0c\u65b9\u6848\u4e8c\u4f9d\u7136\u662f\u5408\u7406\u9009\u62e9\uff0c\u4f46\u9700\u6e05\u695a\u5b83\u5e76\u4e0d\u7701\u94b1\uff0c20\u5e74\u8981\u591a\u4ed8\u7ea61.2\u4e07\u5143\u7684\u8212\u9002\u6ea2\u4ef7\u3002<br><br>\n      <span style=\"color:var(--muted)\">\u53e3\u5f84\u8bf4\u660e\uff1a\u521d\u6295\u8d44C\u2080\u4e3a\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\u6298\u540e\u771f\u503c\u62a5\u4ef7\uff1b\u8fd0\u884c\u8d39R\u6309\u91c7\u6696\u5b63110\u5929\uff0b\u5236\u51b7\u5b6390\u5929\uff0b\u65b0\u98ce\u5168\u5e74365\u5929\u6d4b\u7b97\uff0c\u53c2\u6570\u4e0e\u7b97\u5f0f\u89c1\u4e0a\u65b9\u660e\u7ec6\u8868\uff1b\u7ef4\u62a4\u8d39M\u4e3a\u6309\u5e74\u644a\u7b97\u7684\u4f30\u7b97\u503c\uff1b\u66f4\u6362\u6210\u672c\u6309\u8bbe\u5907\u5bff\u547d\u5468\u671f\u5185\u4e8c\u6b21\u8d2d\u7f6e\u8ba1\u3002\u672a\u8ba1\u901a\u80c0\u4e0e\u80fd\u6e90\u4ef7\u683c\u4e0a\u6da8\uff0c\u4e09\u65b9\u6848\u91c7\u7528\u5b8c\u5168\u76f8\u540c\u7684\u53c2\u6570\u53e3\u5f84\uff0c\u6a2a\u5411\u5bf9\u6bd4\u6709\u6548\u3002<\/span>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- S5 \u6848\u4f8b\u9a8c\u8bc1 -->\n<section id=\"s5\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">S5<\/div><h2>\u6848\u4f8b\u9a8c\u8bc1<\/h2><\/div>\n    <p class=\"sec-sub\">\u540c\u7cfb\u7edf\u3001\u540c\u95e8\u5e97\u7684\u771f\u5b9e\u5b8c\u5de5\u4e0e\u670d\u52a1\u6863\u6848\uff0c\u662f\u4fe1\u4efb\u7684\u8bc1\u636e\u94fe\uff0c\u4e0d\u662f\u5e7f\u544a\u3002<\/p>\n    <div class=\"grid g2\">\n      <a class=\"card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" style=\"display:block\">\n        <h3>\u6848\u4f8b\u4e2d\u5fc3 \u00b7 200+ \u5b8c\u5de5\u5b9e\u5f55<\/h3>\n        <p>\u67e5\u770b\u5357\u5bcc\u68ee\u95e8\u5e97\u540c\u5c0f\u533a\u53ca\u540c\u7cfb\u7edf\uff08\u5c0a\u777f\u5168\u6548\/\u6c34\u5885\u9002\/\u8212\u4eab+\u5730\u6696\uff09\u771f\u5b9e\u6848\u4f8b\u4e0e\u552e\u540e\u8bc4\u4ef7\u3002<\/p>\n      <\/a>\n      <a class=\"card\" href=\"https:\/\/longmai-nt.com\/?page_id=4875\" style=\"display:block\">\n        <h3>\u552e\u540e\u5b9e\u5f55 \u00b7 \u5b89\u88c5\u4e0e\u670d\u52a1<\/h3>\n        <p>\u4f1f\u661f\u661f\u76d1\u7406\u7b2c\u4e09\u65b9\u6253\u538b\u3001VR\u5168\u666f\u3001\u4e09\u65b9\u8054\u4fdd50\u5e74\u670d\u52a1\u6d41\u7a0b\uff0c\u773c\u89c1\u4e3a\u5b9e\u3002<\/p>\n      <\/a>\n    <\/div>\n    <div class=\"backlink\">\n      <b>\u672c\u9879\u76ee\u5bf9\u5916\u5b9e\u666f\u5b8c\u5de5\u5ba3\u4f20\u6848\u4f8b<\/b>\uff1a\u672c\u65b9\u6848\u4e66\u4e3a\u5bf9\u5185\u65b9\u6848\u6863\u6848\uff08\u7f16\u53f7 NFS-WCLD-ZLS-20260801-FA01\uff0cnoindex \u4e0d\u5bf9\u5916\u6536\u5f55\uff09\u3002\u9879\u76ee\u7b7e\u7ea6\u8fdb\u573a\u5e76\u5b8c\u5de5\u540e\uff0c\u5c06\u540c\u6b65\u53d1\u5e03\u5bf9\u5916\u6848\u4f8b\u5206\u4eab\u9875\uff0c\u5c4a\u65f6\u53ef<a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u70b9\u51fb\u67e5\u770b\u5b8c\u5de5\u6848\u4f8b\u5206\u4eab<\/a>\uff08\u6848\u4f8b\u9875\u53d1\u5e03\u540e\u56de\u586b\u672c\u9879\u76ee\u4e13\u5c5e\u94fe\u63a5\uff0c\u5e76\u5728\u6848\u4f8b\u9875\u5c3e\u90e8\u53cd\u5411\u94fe\u63a5\u56de\u672c\u65b9\u6848\u6863\u6848\uff0c\u5f62\u6210\u53cc\u5411\u7ed1\u5b9a\uff09\u3002\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- FAQ -->\n<section id=\"faq\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">Q<\/div><h2>\u5e38\u89c1\u95ee\u9898 FAQ<\/h2><\/div>\n    <p class=\"sec-sub\">\u628a\u5ba2\u6237\u6700\u5728\u610f\u7684\u95ee\u9898\uff0c\u4e00\u6b21\u8bb2\u6e05\u695a\u3002<\/p>\n    <div class=\"faq\">\n      <details open><summary>\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/summary><div class=\"ans\">\u5929\u6c1f\u5730\u6c34\uff1a\u7a7a\u8c03\u4fa7\u8d70\u6c1f\uff08\u51b7\u5a92\uff09\uff0c\u4ec5\u5730\u6696\u4fa7\u8d70\u6c34\uff0c\u7cfb\u7edf\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11\uff1b\u5929\u6c34\u5730\u6c34\uff08\u6c34\u673a\uff09\uff1a\u7a7a\u8c03\u4e0e\u5730\u6696\u4e24\u4fa7\u90fd\u8d70\u6c34\uff0c\u51fa\u98ce\u66f4\u67d4\u548c\u4f46\u90e8\u4ef6\u66f4\u591a\uff08\u6c34\u6cf5\u3001\u677f\u6362\u3001\u8865\u6c34\u9600\u7b49\uff09\u3002\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\u3001\u8ffd\u6c42\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\uff0c\u5929\u6c1f\u5730\u6c34\u66f4\u5339\u914d\u3002<\/div><\/details>\n      <details><summary>\u4e94\u6052\u7cfb\u7edf\u662f\u4e0d\u662f\u5c31\u7b49\u4e8e\u5b89\u9759\u65e0\u58f0\uff1f<\/summary><div class=\"ans\">\u6052\u9759\u4e0d\u7b49\u4e8e\u65e0\u58f0\uff0c\u662f\u63a7\u5236\u5728\u5408\u7406\u5206\u8d1d\u8303\u56f4\u5185\u3002\u4e94\u6052\u662f\u7ec4\u5408\u5f0f\u7cfb\u7edf\u2014\u2014\u4e8c\u8054\u4f9b\u7a7a\u8c03\u5730\u6696\u4e00\u4f53\uff08\u6052\u6e29\uff09\u3001\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff08\u6052\u6e7f\uff09\u3001\u5929\u51c0\u65b0\u98ce\uff08\u6052\u6c27\uff09\u3001PE\u51c0\u5316\u5185\u673a\uff08\u6052\u6d01\uff09\u3001\u4f4e\u566a\u8bbe\u5907+\u9f99\u8109\u7cbe\u5de5\u5b89\u88c5\uff08\u6052\u9759\uff09\uff0c\u7531AI\u96c6\u63a7\u7edf\u4e00\u7ba1\u7406\uff0c\u800c\u975e\u5355\u4e00\u4ea7\u54c1\u3002<\/div><\/details>\n      <details><summary>\u6210\u90fd\u51ac\u5929\u96fe\u973e\u91cd\uff0c\u7a7a\u6c14\u51c0\u5316\u600e\u4e48\u89e3\u51b3\uff1f<\/summary><div class=\"ans\">\u65b9\u6848\u4e00\/\u4e09\u91c7\u7528\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u5185\u673a\uff08\u6052\u6d01\uff09\uff0c\u5168\u7cfb\u6807\u914d\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\uff08\u6052\u6c27+\u8fc7\u6ee4\uff09\uff0c\u7ec4\u5408\u89e3\u51b3\u96fe\u973e\u4e0e\u6362\u6c14\u9700\u6c42\uff1b\u65b0\u98ce\u4ee5\u5367\u5ba4\u98ce\u91cf\u4e3a\u4e3b\uff0c\u4fdd\u8bc1\u7761\u7720\u533a\u7a7a\u6c14\u8d28\u91cf\u3002<\/div><\/details>\n      <details><summary>\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u7528\u70ed\u6c34\u600e\u4e48\u4fdd\u8bc1\u7a33\u5b9a\uff1f<\/summary><div class=\"ans\">\u70ed\u6c34\u662f\u7cfb\u7edf\u95ee\u9898\uff0c\u4e0d\u662f\u4e70\u5927\u70ed\u6c34\u5668\u5c31\u884c\uff0c\u7ba1\u8def\u8bbe\u8ba1\u624d\u662f\u5173\u952e\u3002\u9700\u7ed3\u5408\u96f6\u51b7\u6c34\u5faa\u73af\u3001\u540c\u5f00\u7387\u4e0e\u4e24\u4e2a\u536b\u751f\u95f4\u70b9\u4f4d\u505a\u7ba1\u8def\u6c34\u529b\u8bbe\u8ba1\uff0c\u65b9\u6848\u9884\u7559\u70ed\u6c34\u7cfb\u7edf\u63a5\u53e3\uff0c\u7b7e\u7ea6\u540e\u7531\u987e\u95ee\u51fa\u7ec6\u5316\u56fe\u3002<\/div><\/details>\n      <details><summary>\u8d28\u4fdd\u653f\u7b56\u600e\u4e48\u6837\uff1f\u5341\u5e74\u8d28\u4fdd\u600e\u4e48\u9501\u5b9a\uff1f<\/summary><div class=\"ans\">\u5c0a\u777f\/\u6c34\u5885\u9002\/\u8212\u4eab\u8bbe\u5907\u8d28\u4fdd\u6309\u54c1\u724c\u653f\u7b56\u6267\u884c\uff08\u8be6\u89c1\u62a5\u4ef7\u8bf4\u660e\uff09\uff0c\u5730\u6696\u7531\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd\u4e09\u65b9\u8054\u4fdd50\u5e74\u3002\u54c1\u724c\u67088\u6708\u622a\u6b62\u5341\u5e74\u8d28\u4fdd\u8d44\u683c\u9501\u5b9a\uff0c\u4ea4\u5b9a\u91d1\u5373\u53ef\u9501\u5b9a\uff0c\u5efa\u8bae\u5c3d\u5feb\u786e\u8ba4\u65b9\u6848\u3002<\/div><\/details>\n      <details><summary>\u5730\u6696130\u33a1\u7684\u9020\u4ef7\u5305\u542b\u4ec0\u4e48\uff1f<\/summary><div class=\"ans\">\u6309\u9f99\u8109\u8282\u80fd\u5730\u6696\u7cfb\u7edf\u8ba1\u4ef7\uff08\u963b\u6c27179\u5143\/\u33a1\u4e3a\u6307\u4ee402\u4ef7\u683c\u5e93\u5957\u9910\u4ef7\uff0c\u4e0d\u6253\u6298\uff09\uff0c\u542bPE-RT\u5730\u6696\u7ba1\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u5206\u96c6\u6c34\u5668\u3001\u63a7\u5236\u7ebf\u53ca\u5305\u5de5\u5305\u6599\u5b89\u88c5\uff0c\u4e0d\u542b\u539f\u59cb\u5730\u9762\u627e\u5e73\u53ca\u9632\u6c34\u3002<\/div><\/details>\n      <details><summary>\u8f85\u6750\u6e05\u5355\u91cc\u7684\u54c1\u724c\u53ef\u4ee5\u81ea\u5df1\u9009\u5417\uff1f<\/summary><div class=\"ans\">\u8f85\u6750\u4e00\u5f8b\u6309\u6307\u4ee406\u9ed8\u8ba4\u89c4\u683c\u8f93\u51fa\uff08\u5982\u94dc\u7ba1\u9f99\u715c\u3001\u4fdd\u6e29\u4f18\u83f2\u7279\u3001\u5730\u6696\u4f1f\u661f\uff09\uff0c\u54c1\u724c\u4e3a\u552f\u4e00\u5408\u6cd5\u54c1\u724c\u4e0d\u66ff\u6362\uff1b\u5982\u9500\u552e\u660e\u786e\u6307\u5b9a\u5347\u7ea7\u53ef\u9009\u8f85\u6750\uff0c\u5c06\u66ff\u6362\u5e76\u6807\u6ce8\u201c\u5ba2\u6237\u9009\u914d\u5347\u7ea7\u201d\u3002\u8f85\u6750\u6e05\u5355\u4ec5\u5217\u54c1\u724c\u89c4\u683c\uff0c\u4e0d\u542b\u4ef7\u683c\u3002<\/div><\/details>\n      <details><summary>\u62a5\u4ef7\u91cc\u7684\u6298\u6263\u4f9d\u636e\u662f\u4ec0\u4e48\uff1f<\/summary><div class=\"ans\">\u6298\u6263\u4e25\u683c\u6309\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff1a\u8212\u4eab8\u6298\u3001\u5c0a\u777f\u5168\u65488.5\u6298\u3001\u6c34\u5885\u9002\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\u3001\u83f2\u65af\u66fc\u4e0e\u5730\u6696\u5355\u4ef7\u4e0d\u6253\u6298\u3001160\u6c34\u6a21\u5757\u6309\u672c\u5355\u7ea6\u5b9a\u4e0d\u6253\u6298\u3001\u5929\u51c0\u65b0\u98ce\u4e0e\u96c6\u63a7\u5c4f\u6309\u9762\u4ef7\u5c0a\u777f\u7c7b8.5\u6298\u3002\u6240\u6709\u4ef7\u683c\u4e3a\u6307\u4ee402\u771f\u503c\uff0c\u672a\u5217\u4e0d\u5b9e\u62a5\u3002<\/div><\/details>\n      <details><summary>\u4e09\u65b9\u6848\u521d\u6295\u8d44\u5dee\u5f02\u4e3b\u8981\u6765\u81ea\u54ea\u91cc\uff1f<\/summary><div class=\"ans\">\u65b9\u6848\u4e00\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236+160\u6c34\u6a21\u5757+\u96c6\u63a7\u5c4f\u4e3a\u5168\u6548\u4e94\u6052\u65d7\u8230\u914d\u7f6e\uff0c\u521d\u6295\u6700\u9ad8\uff08106,853\u5143\uff09\uff1b\u65b9\u6848\u4e8c\u6c34\u5885\u9002\u4e3b\u673a\u4e0e\u96f6\u8d8a\u98ce\u76d8\u5747\u4e3a\u96f6\u552e\u4ef7\u4e0d\u6253\u6298\uff0c\u516d\u53f0\u98ce\u76d8\u9010\u53f0\u6838\u4ef718,924\u5143\uff0c\u52a0\u6c34\u7cfb\u7edf\u5b89\u88c5\uff086\u53f0\u5185\u673a+1\u53f0\u4e3b\u673a\uff09\u00d73,200\u5143\/\u53f0\u00d78\u6298\uff1d17,920\u5143\uff0c\u5408\u8ba1104,499\u5143\uff0c\u4e0e\u65b9\u6848\u4e00\u4ec5\u5dee2,354\u5143\uff1b\u65b9\u6848\u4e09\u8212\u4eab\u4e3b\u673a8\u6298\u6700\u4fbf\u5b9c\uff0c\u52a0\u83f2\u65af\u66fc\u9505\u7089\u540e89,304\u5143\u4e3a\u4e09\u65b9\u6848\u6700\u4f4e\u300220\u5e74\u603b\u8d26\u9700\u7ed3\u5408\u8fd0\u884c\u8d39\u4e0e\u7ef4\u62a4\u8d39\u7efc\u5408\u8bc4\u4f30\u3002<\/div><\/details>\n      <details><summary>\u6c34\u5885\u9002\u516d\u53f0\u98ce\u76d8\u4e3a\u4ec0\u4e48\u4e0d\u80fd\u6309\u5747\u4ef7\u4f30\u7b97\uff1f<\/summary><div class=\"ans\">\u6c34\u5885\u9002\u98ce\u673a\u76d8\u7ba1\u5728\u4ef7\u683c\u5e93\u4e2d\u5206 AC\u3001\u7b80\u7ea6DC\u3001\u96f6\u8d8a \u4e09\u4e2a\u6863\u4f4d\uff0c\u540c\u89c4\u683c\u4ef7\u5dee\u6700\u9ad8\u53ef\u8fbe\u4e09\u500d\u2014\u2014\u4ee5136\u578b\u4e3a\u4f8b\uff0cAC 1,835\u5143\u3001\u7b80\u7ea6DC 3,951\u5143\u3001\u96f6\u8d8a 4,700\u5143\u3002\u672c\u6237\u516d\u53f0\u89c4\u683c\u4ece34\u578b\u5230136\u578b\u5404\u4e0d\u76f8\u540c\uff0c\u5fc5\u987b\u9010\u53f0\u6309\u578b\u53f7\u53d6\u4ef7\uff1a4,700\uff0b3,136\uff0b2,625\uff0b2,625\uff0b3,086\uff0b2,752\uff1d18,924\u5143\u3002\u672c\u65b9\u6848\u5df2\u5217\u51fa\u9010\u53f0\u6838\u4ef7\u660e\u7ec6\u8868\uff0c\u53ef\u5bf9\u7167\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\uff08page_id=662\uff09\u9644\u5f55\u4e8c\u00b72.3\u9010\u6761\u590d\u6838\u3002<\/div><\/details>\n      <details><summary>\u65b9\u6848\u4e8c\u6c34\u5885\u9002\u7684\u5b89\u88c5\u8d39\u4e3a\u4ec0\u4e48\u5355\u72ec\u5217\u51fa\u6765\uff1f<\/summary><div class=\"ans\">\u6c34\u7cfb\u7edf\uff08\u5929\u6c34\u5730\u6c34\uff09\u4e3b\u673a\u4e0e\u672b\u7aef\u5747\u9700\u73b0\u573a\u6c34\u8def\u8fde\u63a5\u3001\u6c34\u538b\u8bd5\u9a8c\u4e0e\u6c34\u8d28\u5904\u7406\uff0c\u5b89\u88c5\u5de5\u7a0b\u91cf\u4e0e\u6c1f\u7cfb\u7edf\u4e0d\u540c\uff0c\u56e0\u6b64\u6309\u53f0\u6570\u5355\u72ec\u8ba1\u53d6\uff1a\uff08\u5185\u673a6\u53f0\uff0b\u4e3b\u673a1\u53f0\uff09\u00d73,200\u5143\/\u53f0\u00d78\u6298\uff1d17,920\u5143\u3002\u65b9\u6848\u4e00\/\u65b9\u6848\u4e09\u7684\u5185\u673a\u5b89\u88c5\u8d39\u5df2\u542b\u5728\u8bbe\u5907\u542b\u5b89\u88c5\u62a5\u4ef7\u5185\uff0c\u4e0d\u91cd\u590d\u8ba1\u53d6\uff0c\u53e3\u5f84\u4e00\u81f4\u53ef\u76f4\u63a5\u6a2a\u5411\u6bd4\u8f83\u3002<\/div><\/details>\n      <details><summary>\u5929\u6c1f\u5730\u6c34\u65b9\u6848\u771f\u7684\u6700\u770120\u5e74\u603b\u8d26\u5417\uff1f<\/summary><div class=\"ans\">\u662f\u7684\uff0c\u65b9\u6848\u4e00190,053\u5143\u4e3a\u4e09\u65b9\u6848\u6700\u4f4e\uff1a\u6bd4\u65b9\u6848\u4e8c202,099\u5143\u4f4e12,046\u5143\uff0c\u6bd4\u65b9\u6848\u4e09210,301\u5143\u4f4e20,248\u5143\u3002\u5173\u952e\u5728\u4e8e\u4e24\u4e2a\u4e8c\u8054\u4f9b\u7684\u521d\u6295\u51e0\u4e4e\u6301\u5e73\uff08\u4ec5\u5dee2,354\u5143\uff09\uff0c\u800c\u65b9\u6848\u4e00\u6bcf\u5e74\u8fd0\u884c\u8d39\u5c11220\u5143\u3001\u7ef4\u62a4\u8d39\u5c11500\u5143\uff0c\u7b2c4\u5e74\u5373\u5b8c\u6210\u53cd\u8d85\u3002\u65b9\u6848\u4e09\u5219\u76f8\u53cd\uff0c\u521d\u6295\u6700\u4f4e\u4f46\u91c7\u6696\u70e7\u6c14\u4e14\u7b2c10\u5e74\u9700\u66f4\u6362\u51b7\u51dd\u7089\uff0c\u957f\u671f\u6700\u8d35\u3002\u8fd0\u884c\u8d39\u6309\u91c7\u6696\u5b63110\u5929\u3001\u5236\u51b7\u5b6390\u5929\u3001\u65b0\u98ce\u5168\u5e74365\u5929\u6d4b\u7b97\uff0c\u660e\u7ec6\u8868\u5df2\u516c\u5f00\u5168\u90e8\u53c2\u6570\u53ef\u81ea\u884c\u9a8c\u7b97\u3002<\/div><\/details>\n      <details><summary>\u4e3a\u4ec0\u4e48\u4e24\u4e2a\u4e8c\u8054\u4f9b\u7684\u91c7\u6696\u8d39\u5b8c\u5168\u4e00\u6837\uff1f<\/summary><div class=\"ans\">\u56e0\u4e3a\u91c7\u6696\u4fa7\u7684\u7269\u7406\u8fc7\u7a0b\u662f\u540c\u4e00\u4ef6\u4e8b\uff1a\u65b9\u6848\u4e00\uff08\u5929\u6c1f\u5730\u6c34\uff09\u548c\u65b9\u6848\u4e8c\uff08\u5929\u6c34\u5730\u6c34\uff09\u90fd\u662f\u70ed\u6cf5\u4e3b\u673a\u5236\u53d635\uff5e40\u2103\u70ed\u6c34\uff0c\u518d\u9001\u8fdb130\u33a1\u5730\u6696\u76d8\u7ba1\u3002\u70ed\u6e90\u76f8\u540c\u3001\u51fa\u6c34\u6e29\u5ea6\u76f8\u540c\u3001\u5730\u6696\u6563\u70ed\u65b9\u5f0f\u76f8\u540c\uff0c\u80fd\u8017\u81ea\u7136\u76f8\u540c\u2014\u2014\u91c7\u6696\u5b63110\u5929\u5404\u7ea62,570\u5143\u3002\u4e24\u8005\u7684\u5dee\u5f02\u53ea\u5728\u7a7a\u8c03\u4fa7\uff1a\u65b9\u6848\u4e00\u7a7a\u8c03\u8d70\u6c1f\uff08\u76f4\u81a8\uff09\uff0c\u65b9\u6848\u4e8c\u7a7a\u8c03\u4e5f\u8d70\u6c34\u3002\u6240\u4ee5\u4efb\u4f55\u8bf4&#8221;\u5929\u6c1f\u5730\u6c34\u6bd4\u5929\u6c34\u5730\u6c34\u91c7\u6696\u66f4\u7701&#8221;\u7684\u8bf4\u6cd5\u90fd\u662f\u4e0d\u6210\u7acb\u7684\uff0c\u6211\u4eec\u4e0d\u505a\u8fd9\u79cd\u8bef\u5bfc\u3002<\/div><\/details>\n      <details><summary>\u65b9\u6848\u4e8c\u6c34\u5885\u9002\u4e3a\u4ec0\u4e48\u5236\u51b7\u6bd4\u53e6\u5916\u4e24\u4e2a\u65b9\u6848\u8d39\u7535\uff1f<\/summary><div class=\"ans\">\u4e24\u4e2a\u539f\u56e0\u3002\u4e00\u662f\u4e8c\u6b21\u6362\u70ed\uff1a\u6c1f\u7cfb\u7edf\u51b7\u5a92\u76f4\u63a5\u5728\u5ba4\u5185\u673a\u84b8\u53d1\u6362\u70ed\uff0c\u6c34\u7cfb\u7edf\u8981\u5148\u628a\u51b7\u5a92\u7684\u51b7\u91cf\u4f20\u7ed9\u51b7\u51bb\u6c34\u3001\u518d\u7531\u51b7\u51bb\u6c34\u4f20\u7ed9\u672b\u7aef\uff0c\u591a\u4e00\u6b21\u6362\u70ed\u5c31\u591a\u4e00\u6b21\u6e29\u5dee\u635f\u5931\uff0c\u4e3b\u673a\u84b8\u53d1\u6e29\u5ea6\u5fc5\u987b\u538b\u5f97\u66f4\u4f4e\uff0c\u7efc\u5408EER\u4ece3.3\u964d\u5230\u7ea62.90\u3002\u4e8c\u662f\u6c34\u6cf5\uff1a\u5168\u6c34\u7cfb\u7edf\u9700\u8981\u5faa\u73af\u6cf5\u5e38\u5e74\u8fd0\u884c\uff0c\u6309250W\u00d78\u5c0f\u65f6\u00d790\u5929\u8ba1\u7ea6108\u5143\u3002\u4e24\u9879\u76f8\u52a0\uff0c\u5236\u51b7\u5b63\u7ea6690\u5143\uff0c\u6bd4\u65b9\u6848\u4e00\u6c1f\u4fa7\u76f4\u81a8\u7684470\u5143\u9ad8\u7ea647%\u3002\u8fd9\u662f\u6c34\u7cfb\u7edf\u7684\u56fa\u6709\u4ee3\u4ef7\uff0c\u4e0d\u662f\u4ea7\u54c1\u597d\u574f\u95ee\u9898\u3002<\/div><\/details>\n      <details><summary>\u71c3\u6c14\u51b7\u51dd\u7089\u91c7\u6696\u5230\u5e95\u6bd4\u70ed\u6cf5\u8d35\u591a\u5c11\uff1f<\/summary><div class=\"ans\">\u6309\u672c\u6237130\u33a1\u5730\u6696\u6d4b\u7b97\uff1a\u91c7\u6696\u5b63\u603b\u70ed\u9700\u6c42\u7ea612,012 kWh\u3002\u70ed\u6cf5\u5728\u4f4e\u6e29\u5730\u6696\u5de5\u51b5COP\u53d62.8\uff0c\u8017\u75354,290\u5ea6\uff0c\u63090.60\u5143\/\u5ea6\u7b972,574\u5143\uff1b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u630998%\u5b63\u8282\u6548\u7387\u6298\u7b97\u8017\u6c141,242\u7acb\u65b9\u7c73\uff0c\u63092.70\u5143\/\u7acb\u65b9\u7c73\u7b973,353\u5143\uff0c\u53e6\u52a0\u9505\u7089\u81ea\u8eab\u5faa\u73af\u6cf5\u4e0e\u98ce\u673a\u8017\u7535\u7ea687\u5143\uff0c\u5408\u8ba13,440\u5143\u3002<b>\u6bcf\u5e74\u591a\u7ea6870\u5143\uff0c20\u5e74\u7d2f\u8ba1\u7ea617,400\u5143\u3002<\/b>\u800c\u4e14\u71c3\u6c14\u662f\u9636\u68af\u8ba1\u4ef7\uff0c\u7528\u91cf\u8d8a\u5927\u5355\u4ef7\u8d8a\u9ad8\uff0c\u8fd9\u4e2a\u5dee\u989d\u53ea\u4f1a\u6269\u5927\u4e0d\u4f1a\u7f29\u5c0f\u3002<\/div><\/details>\n      <details><summary>\u4e3a\u4ec0\u4e48\u65b9\u6848\u4e09\u8981\u7b97\u4e00\u6b21\u8bbe\u5907\u66f4\u6362\uff0c\u4e24\u4e2a\u4e8c\u8054\u4f9b\u5374\u4e0d\u7528\uff1f<\/summary><div class=\"ans\">\u8fd9\u662f\u8bbe\u5907\u5bff\u547d\u7684\u5ba2\u89c2\u5dee\u5f02\u3002\u65e5\u7acb\u70ed\u6cf5\u4e3b\u673a\u630920\u5e74\u7cfb\u7edf\u5bff\u547d\u8bbe\u8ba1\uff0c20\u5e74\u5468\u671f\u5185\u4e0d\u9700\u8981\u4e8c\u6b21\u8d2d\u7f6e\uff1b\u65b9\u6848\u4e8c\u7684\u6c34\u6cf5\u3001\u677f\u6362\u5c5e\u4e8e\u53ef\u7ef4\u4fee\u66f4\u6362\u7684\u8f85\u4ef6\uff0c\u6210\u672c\u5df2\u7ecf\u644a\u8fdb\u4e86\u6bcf\u5e741,100\u5143\u7684\u7ef4\u62a4\u8d39\u91cc\uff0c\u4e0d\u91cd\u590d\u8ba1\u4e3a\u66ff\u6362\u6210\u672c\u3002\u800c\u71c3\u6c14\u51b7\u51dd\u7089\u7684\u6362\u70ed\u5668\u4e0e\u71c3\u70e7\u7ec4\u4ef6\u662f\u6d88\u8017\u6027\u90e8\u4ef6\uff0c\u5bff\u547d\u901a\u5e3810\uff5e12\u5e74\uff0c20\u5e74\u5468\u671f\u5185\u5fc5\u987b\u6574\u673a\u66f4\u63621\u6b21\uff0c\u6309\u5f53\u524d\u5355\u4ef713,597\u5143\u8ba1\u5165\uff08\u8fd8\u6ca1\u7b97\u901a\u80c0\uff0c\u5b9e\u9645\u66f4\u6362\u65f6\u5927\u6982\u7387\u66f4\u8d35\uff09\u3002\u8fd9\u4e00\u7b14\u6b63\u597d\u5728\u7b2c10\u5e74\u53d1\u751f\uff0c\u4e5f\u6b63\u662f\u65b9\u6848\u4e09\u603b\u8d26\u88ab\u53cd\u8d85\u7684\u65f6\u70b9\u3002<\/div><\/details>\n      <details><summary>\u5929\u51c0\u65b0\u98ce350\u4e00\u53f0\u80fd\u7ba1\u4e24\u5c42\u5417\uff1f<\/summary><div class=\"ans\">\u5929\u51c0\u65b0\u98ce350\u98ce\u91cf350m\u00b3\/h\uff0c\u672c\u65b9\u6848\u7528\u4e8e\u4e8c\u5c42\u5367\u5ba4\u4e3a\u4e3b\uff0c\u4fdd\u8bc1\u5367\u5ba4\u98ce\u91cf\uff1b\u4e00\u5c42\u5982\u9700\u8981\u53ef\u53e6\u505a\u98ce\u91cf\u6821\u6838\u6216\u589e\u914d\uff0c\u4ee5\u73b0\u573a\u5b9a\u4f4d\u540e\u5b9e\u9645\u4e3a\u51c6\uff0c\u62a5\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\u3002<\/div><\/details>\n      <details><summary>\u9f99\u8109\u6696\u901a\u6709\u54ea\u4e9b\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u8d44\u8d28\uff1f<\/summary><div class=\"ans\">\u9f99\u8109\u6696\u901a\u6301\u6709\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09\u3001\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\uff082026\uff09\u3001\u7279\u7ea6\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09\u3001\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u5546\u4e13\u9879\u6388\u6743\u3001\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082024\uff09\u5171\u4e94\u9879\u8d44\u8d28\uff0c\u65b9\u6848\u4e66\u300c\u54c1\u724c\u6388\u6743\u300d\u7ae0\u8282\u5185\u4e3a\u8bc1\u4e66\u5b9e\u62cd\u3002\u6388\u6743\u51b3\u5b9a\u7684\u4e0d\u53ea\u662f\u80fd\u4e0d\u80fd\u5356\uff0c\u66f4\u662f\u80fd\u5426\u4eab\u53d7\u539f\u5382\u5b89\u88c5\u6807\u51c6\u3001\u539f\u5382\u914d\u4ef6\u4e0e\u6574\u673a\u8d28\u4fdd\u653f\u7b56\u3002<\/div><\/details>\n      <details><summary>\u5e38\u4f4f3\u81f34\u4eba\u5bf9\u9009\u578b\u6709\u4ec0\u4e48\u5f71\u54cd\uff1f<\/summary><div class=\"ans\">\u5e38\u4f4f3\uff5e4\u4eba\u3001\u516d\u4e2a\u623f\u95f4\u5b9e\u9645\u5e38\u5f002\uff5e3\u53f0\uff0c\u540c\u5f00\u7387\u7ea640%\uff5e50%\uff0c\u5c5e\u4e2d\u7b49\u504f\u4f4e\u3002\u6c34\u673a\u7684\u201c\u8bbe\u8ba1\u81ea\u7531\u201d\u4f18\u52bf\u9700\u8981\u5728\u4f4e\u540c\u5f00\u7387<em>\u4e14<\/em>\u5927\u4f53\u91cf\uff08\u901a\u5e38200\u33a1\u4ee5\u4e0a\uff09\u65f6\u624d\u5212\u7b97\uff0c\u672c\u6237\u91c7\u6696130\u33a1\u672a\u5230\u4e34\u754c\u70b9\uff1b\u540c\u65f63\uff5e4\u4eba\u4e24\u536b\u540c\u65f6\u7528\u70ed\u6c34\u7684\u6982\u7387\u4e0d\u4f4e\uff0c\u70ed\u6c34\u4fa7\u9700\u6309\u96f6\u51b7\u6c34\u5faa\u73af\u505a\u7ba1\u8def\u8bbe\u8ba1\uff0c\u800c\u975e\u5355\u7eaf\u653e\u5927\u70ed\u6c34\u5668\u5bb9\u91cf\u3002<\/div><\/details>\n      <details><summary>\u4e3a\u4ec0\u4e48\u987e\u95ee\u503e\u5411\u5929\u6c1f\u5730\u6c34\u800c\u4e0d\u662f\u76f4\u63a5\u63a8\u6c34\u673a\uff1f<\/summary><div class=\"ans\">\u590d\u5f0f\u6d0b\u623f\u91c7\u6696130\u33a1\u3001\u5e38\u4f4f3\uff5e4\u4eba\u3001\u5e38\u5f00\u533a\u57df\u56fa\u5b9a\uff08\u4e00\u697c\u5ba2\u9910\u5385+\u4e8c\u697c\u4e3b\u5367\uff09\u3001\u5ba2\u6237\u8ffd\u6c42\u201c\u7a33\u5b9a\u4e0d\u51fa\u95ee\u9898\u201d\uff0c\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u7b80\u6d01\u6545\u969c\u70b9\u5c11\u66f4\u5339\u914d\uff1b\u6c34\u673a\u7684\u201c\u8bbe\u8ba1\u81ea\u7531\u3001\u51fa\u98ce\u67d4\u548c\u201d\u4f18\u52bf\u4e3b\u8981\u5728\u4f4e\u540c\u5f00\u7387\u5927\u6237\u578b\u624d\u663e\u73b0\u3002\u6211\u4eec\u505a\u4e13\u4e1a\u5bf9\u6bd4\u4e0d\u56de\u907f\u52a3\u52bf\uff0c\u5e2e\u5ba2\u6237\u9009\u6700\u9002\u5408\u7684\u800c\u975e\u6700\u8d35\u7684\u3002<\/div><\/details>\n      <details><summary>\u65b9\u6848\u4e66\u91cc\u7684\u56fe\u7247\u4f1a\u88c2\u56fe\u5417\uff1f<\/summary><div class=\"ans\">\u4ea7\u54c1\u5c55\u793a\u91c7\u7528\u7ed3\u6784\u5316\u5361\u7247\uff08\u54c1\u724c+\u578b\u53f7+\u5356\u70b9\uff09\uff0c\u95e8\u5e97\u5b9e\u666f\u4e3a\u9f99\u8109\u5b98\u65b9\u6388\u6743\u95e8\u5e97\u7167\u7247\uff1b\u53d1\u5e03\u81f3\u5b98\u7f51\u65f6\u56fe\u7247URL\u6309\u89c4\u5219\u5904\u7406\u907f\u514d\u4e8c\u6b21\u8ffd\u52a0\u540e\u7f00\uff0c\u786e\u4fdd\u4e0d\u88c2\u56fe\u3002<\/div><\/details>\n      <details><summary>\u65b9\u6848\u662f\u5426\u5305\u542b\u5e73\u9762\u56fe\u786e\u8ba4\u7684\u7cbe\u786e\u914d\u7f6e\uff1f<\/summary><div class=\"ans\">\u672c\u65b9\u6848\u4f9d\u636e\u5df2\u63d0\u4f9b\u7684\u5efa\u7b51\u8be6\u60c5\uff08\u590d\u5f0f\u6d0b\u623f\u3001\u91c7\u6696130\u33a1\u3001\u5404\u623f\u95f4\u9762\u79ef\u4e0e\u5185\u673a\u914d\u7f6e\uff09\u751f\u6210\uff1b\u5f85\u6b63\u5f0f\u5e73\u9762\u56fe\u4e0e\u5e38\u4f4f\u4eba\u6570\/\u540c\u5f00\u7387\u786e\u8ba4\u540e\uff0c\u53ef\u5fae\u8c03\u5185\u673a\u70b9\u4f4d\u4e0e\u4e3b\u673a\u9009\u578b\uff0c\u62a5\u4ef7\u4ee5\u6700\u7ec8\u7b7e\u7ea6\u7248\u4e3a\u51c6\u3002<\/div><\/details>\n      <details><summary>\u5b89\u88c5\u548c\u552e\u540e\u7531\u8c01\u8d1f\u8d23\uff1f<\/summary><div class=\"ans\">\u7531\u9f99\u8109\u6696\u901a\u81ea\u6709\u6280\u5e08\u56e2\u961f\u5b89\u88c5\uff0c\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u201c\u661f\u76d1\u7406\u201d\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f\uff1b\u5730\u6696\u4e09\u65b9\u8054\u4fdd\uff08\u9f99\u8109+\u4f1f\u661f+\u4e2d\u56fd\u4eba\u4fdd\uff09\u3002\u552e\u540e\u5b9e\u5f55\u53ef\u5728\u6848\u4f8b\u4e2d\u5fc3\u67e5\u770b\u540c\u5c0f\u533a\u53ca\u540c\u7cfb\u7edf\u5b8c\u5de5\u6848\u4f8b\u3002<\/div><\/details>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- \u4e86\u89e3\u66f4\u591a -->\n<section id=\"more\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">+<\/div><h2>\u4e86\u89e3\u66f4\u591a<\/h2><\/div>\n    <div class=\"more\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u4ea7\u54c1\u8be6\u60c5 \u00b7 \u5c0a\u777f\u5168\u6548<small>page_id 1811<\/small><\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1233\">\u4ea7\u54c1\u8be6\u60c5 \u00b7 \u6c34\u5885\u9002<small>page_id 1233<\/small><\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\">\u4ea7\u54c1\u8be6\u60c5 \u00b7 \u8212\u4eab<small>page_id 1077<\/small><\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u6848\u4f8b\u4e2d\u5fc3 \u00b7 200+\u5b9e\u5f55<small>page_id 2297<\/small><\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1841\">\u54c1\u724c \u00b7 \u66fc\u745e\u5fb7\u63a7\u5236<small>page_id 1841<\/small><\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1824\">\u54c1\u724c \u00b7 \u83f2\u65af\u66fc<small>page_id 1824<\/small><\/a>\n      <a href=\"tel:02886131795\">\u6388\u6743\u95e8\u5e97 \u00b7 \u5357\u5bcc\u68ee<small>028-86131795<\/small><\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=3023\">\u7ad9\u70b9\u5730\u56fe \u00b7 \u5168\u5bfc\u822a<small>page_id 3023<\/small><\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- \u9644\u5f55\uff1a\u54c1\u724c\u6388\u6743 -->\n<section id=\"certs\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">\u8bc1<\/div><h2>\u54c1\u724c\u6388\u6743 \u00b7 \u8d44\u8d28\u5b9e\u62cd<\/h2><\/div>\n    <p class=\"sec-sub\">\u9f99\u8109\u6696\u901a\u6301\u6709\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u8d44\u8d28\u3002\u6388\u6743\u8bc1\u4e66\u51b3\u5b9a\u7684\u4e0d\u53ea\u662f\u80fd\u4e0d\u80fd\u5356\uff0c\u66f4\u662f\u80fd\u4e0d\u80fd\u4eab\u53d7\u539f\u5382\u5b89\u88c5\u6807\u51c6\u3001\u539f\u5382\u914d\u4ef6\u4e0e\u6574\u673a\u8d28\u4fdd\u653f\u7b56\u2014\u2014\u8fd9\u662f\u65b9\u6848\u80fd\u5426\u5151\u73b0\u7684\u524d\u63d0\u3002\u4ee5\u4e0b\u4e3a\u8bc1\u4e66\u5b9e\u62cd\u3002<\/p>\n    <div class=\"certs\">\n      <div class=\"cert\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u5546\u6388\u6743\u8bc1\u4e662026\">\n        <div class=\"cl\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u94bb\u77f3\u5b89\u88c5\u670d\u52a1<small>2026\u5e74\u5ea6\u6388\u6743<\/small><\/div>\n      <\/div>\n      <div class=\"cert\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\u8bc1\u4e662026\">\n        <div class=\"cl\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u7279\u7ea6\u7ecf\u9500\u5546<small>2026\u5e74\u5ea6\u6388\u6743<\/small><\/div>\n      <\/div>\n      <div class=\"cert\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u5b89\u88c5\u670d\u52a1\u5546\u6388\u6743\u8bc1\u4e662026\">\n        <div class=\"cl\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u7279\u7ea6\u5b89\u88c5\u670d\u52a1<small>2026\u5e74\u5ea6\u6388\u6743<\/small><\/div>\n      <\/div>\n      <div class=\"cert\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\u8bc1\u4e66\">\n        <div class=\"cl\">\u65e5\u7acb\u6c34\u5885\u9002 \u00b7 \u7279\u7ea6\u7ecf\u9500\u5546<small>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u4e13\u9879\u6388\u6743<\/small><\/div>\n      <\/div>\n      <div class=\"cert\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u5546\u6388\u6743\u8bc1\u4e662024\">\n        <div class=\"cl\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u91d1\u724c\u5b89\u88c5\u670d\u52a1<small>2024\u5e74\u5ea6\u6388\u6743<\/small><\/div>\n      <\/div>\n    <\/div>\n    <div class=\"note\">\u5f20\u8001\u5e08\u672c\u6b21\u4e09\u65b9\u6848\u6d89\u53ca\u7684\u5c0a\u777f\u5168\u6548\u3001\u6c34\u5885\u9002\u3001\u8212\u4eab\u4e09\u6761\u4ea7\u54c1\u7ebf\uff0c\u9f99\u8109\u5747\u6301\u6709\u5bf9\u5e94\u6388\u6743\uff1a\u6c34\u5885\u9002\u4e3a\u4e13\u9879\u7279\u7ea6\u7ecf\u9500\u6388\u6743\uff0c\u5c0a\u777f\u5168\u6548\u4e0e\u8212\u4eab\u5728\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u8303\u56f4\u5185\u3002\u5b89\u88c5\u4fa7\u540c\u65f6\u5177\u5907\u94bb\u77f3\u7ea7\u4e0e\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u8d44\u8d28\uff0c\u53ef\u6267\u884c\u539f\u5382\u5b89\u88c5\u9a8c\u6536\u6807\u51c6\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- \u95e8\u5e97 + CTA -->\n<section id=\"stores\" class=\"appendix\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">\u5e97<\/div><h2>\u6388\u6743\u95e8\u5e97 \u00b7 \u53cc\u5e97\u4fdd\u969c<\/h2><\/div>\n    <p class=\"sec-sub\">\u5357\u5317\u53cc\u5e97\u5b9e\u4f53\u7ecf\u8425\uff0c\u65b9\u6848\u3001\u65bd\u5de5\u3001\u552e\u540e\u540c\u4e00\u652f\u56e2\u961f\u95ed\u73af\u8d1f\u8d23\u3002\u6b22\u8fce\u968f\u65f6\u5230\u5e97\u770b\u6837\u673a\u3001\u770b\u9690\u853d\u5de5\u7a0b\u5b9e\u7269\u5899\u3002<\/p>\n    <div class=\"stores\">\n      <div class=\"store\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\u5b9e\u666f\">\n        <div class=\"si\">\n          <h4>\u9f99\u8109\u6696\u901a \u00b7 \u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/h4>\n          <a class=\"tel\" href=\"tel:02886131795\">028-86131795<\/a>\n          <p>\u5f20\u8001\u5e08\u672c\u6b21\u8fdb\u5e97\u95e8\u5e97 \u00b7 \u9500\u552e\u987e\u95ee \u4f59\u6653\u73b2\uff08\u4ece\u4e1a22\u5e74\uff09<br><a href=\"tel:13008113409\" style=\"color:var(--gold-d);font-weight:700\">\u76f4\u7ebf 13008113409<\/a><\/p>\n          <div class=\"addr\">\u6210\u90fd\u5e02\u6b66\u4faf\u533a \u00b7 \u5bcc\u68ee\u7f8e\u5bb6\u5c45\uff08\u5357\u5bcc\u68ee\uff09\u5efa\u6750\u9986<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"store\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97\u5b9e\u666f\">\n        <div class=\"si\">\n          <h4>\u9f99\u8109\u6696\u901a \u00b7 \u5317\u5bcc\u68ee\u5e97<\/h4>\n          <a class=\"tel\" href=\"tel:02865272586\">028-65272586<\/a>\n          <p>\u540c\u6807\u51c6\u65b9\u6848\u3001\u540c\u6807\u51c6\u65bd\u5de5\u3001\u540c\u6807\u51c6\u8054\u4fdd<\/p>\n          <div class=\"addr\">\u6210\u90fd\u5e02\u91d1\u725b\u533a \u00b7 \u5bcc\u68ee\u7f8e\u5bb6\u5c45\uff08\u5317\u5bcc\u68ee\uff09\u5efa\u6750\u9986<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <div class=\"svc\"><b>\u670d\u52a1\u8303\u56f4<\/b>\uff1a\u6210\u90fd\u9ad8\u65b0\u533a \u00b7 \u53cc\u6d41\u533a \u00b7 \u90eb\u90fd\u533a \u00b7 \u9f99\u6cc9\u9a7f\u533a \u00b7 \u5929\u5e9c\u65b0\u533a \u00b7 \u89c6\u9ad8\uff0c\u542b\u9e93\u6e56\u751f\u6001\u57ce\u5168\u57df\uff08\u4e94\u5f69\u6797\u5824\u7b49\u7ec4\u56e2\uff09\u3002<br><b>\u5b98\u7f51<\/b>\uff1a<a href=\"https:\/\/longmai-nt.com\/\" style=\"color:var(--gold-d);font-weight:700\">longmai-nt.com<\/a> \u00b7 \u6848\u4f8b\u4e2d\u5fc3\u4e0e\u552e\u540e\u5b9e\u5f55\u5747\u53ef\u5728\u7ebf\u67e5\u9605\u3002<\/div>\n    <div class=\"cta\">\n      <h3>\u5f20\u8001\u5e08\uff0c\u65b9\u6848\u5df2\u5c31\u4f4d \u2014\u2014 \u4e0b\u4e00\u6b65\u9501\u5b9a\u5341\u5e74\u8d28\u4fdd<\/h3>\n      <p>\u54c1\u724c\u67088\u6708\u622a\u6b62\u5341\u5e74\u8d28\u4fdd\u8d44\u683c\uff0c\u4ea4\u5b9a\u91d1\u5373\u53ef\u9501\u5b9a\u3002\u5efa\u8bae\u63d0\u4f9b\u6b63\u5f0f\u5e73\u9762\u56fe\uff0c\u5373\u53ef\u5c06\u672c\u65b9\u6848\u9501\u5b9a\u4e3a\u7b7e\u7ea6\u7248\u5e76\u51fa\u5185\u673a\u70b9\u4f4d\u56fe\u3002<\/p>\n      <div class=\"btns\">\n        <a href=\"tel:02886131795\">\u5357\u5bcc\u68ee 028-86131795<\/a>\n        <a href=\"tel:02865272586\">\u5317\u5bcc\u68ee 028-65272586<\/a>\n        <a class=\"ghost\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u770b\u540c\u7cfb\u7edf\u6848\u4f8b<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- \u9644\u5f55\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u6307\u4ee406 -->\n<section id=\"annex\" class=\"appendix\">\n  <div class=\"wrap\">\n    <div class=\"sec-h\"><div class=\"sec-n\">\u9644<\/div><h2>\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355<\/h2><\/div>\n    <p class=\"sec-sub\">\u4f9d\u636e\u6307\u4ee406\u81ea\u52a8\u751f\u6210\uff1a\u4ec5\u5217\u54c1\u724c+\u89c4\u683c+\u529f\u80fd\uff0c\u4e0d\u542b\u4ef7\u683c\u3001\u4e0d\u542b\u65bd\u5de5\u6307\u5bfc\uff1b\u5168\u90e8\u9ed8\u8ba4\u89c4\u683c\uff0c\u54c1\u724c\u552f\u4e00\u5408\u6cd5\u4e0d\u66ff\u6362\uff1b\u591a\u7cfb\u7edf\u6309\u300c\u7a7a\u8c03 \/ \u65b0\u98ce \/ \u5730\u6696\u300d\u987a\u5e8f\u3002<\/p>\n\n    <!-- \u65b9\u6848\u4e00\uff1aG + B + C -->\n    <details class=\"annex\" open>\n      <summary>\u65b9\u6848\u4e00 \u00b7 \u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u4e94\u6052 \u2014\u2014 \u9644\u8868G\uff08\u5929\u6c1f\u5730\u6c34\uff09+ \u9644\u8868B\uff08\u65b0\u98ce\uff09+ \u9644\u8868C\uff08\u5730\u6696\uff09<\/summary>\n      <div class=\"acont\">\n        <h4>\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u9644\u8868G\uff09<\/h4>\n        <p><b>\u9002\u7528\u7cfb\u7edf<\/b>\uff1a\u65e5\u7acb\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/p>\n        <table class=\"tbl\">\n          <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u7b49\u4e8e\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr>\n            <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr>\n            <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr>\n            <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5bf9\u51b7\u5a92\u8fdb\u884c\u5206\u914d<\/td><\/tr>\n            <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><\/tr>\n            <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n            <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>\u539a\u5ea620mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n            <tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea6\u4e3a15mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u540a\u5361<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u5361\uff08\u914d\u62b1\u7b8d\uff09<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u7ba1\u8def\u5b89\u88c5\uff0c\u5347\u7ea7\u5de5\u827a<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6750<\/td><td>\u4e1d\u6760\u3001\u81a8\u80c0\u3001\u51cf\u9707\u57ab\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u5b89\u88c5\u56fa\u5b9a<\/td><\/tr>\n            <tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr>\n            <tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\u7b49<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u8fd0\u8f93\u8d39<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td><\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>FPPRCT(\u4e3b\u7ba1)<\/td><td>dn32*en2.9\/dn40*en3.7\/dn50*en4.6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr>\n            <tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u4e3b\u7ba1)<\/td><td>\u03c632*20\/\u03c640*20\/\u03c650*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9\/\u7ba1\u9053\u4fdd\u6e29\uff0c\u51cf\u5c11\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c42\u697c\u4e00\u4e2a<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\u3001\u5206\u8def\u63a7\u5236\u3001\u6392\u6c14\u6392\u6c61\u9600\u4fbf\u4e8e\u7cfb\u7edf\u68c0\u4fee\u548c\u7ef4\u62a4<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u9002\u914d\u4e00\u4f53\u89d2\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\uff0c\u76f4\u63a5\uff0c\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u4e3b\u7ba1\u7ba1\u9053<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u622a\u6b62\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u6d3b\u63a5\u9600\u95e8\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u91d1\u5c5e\u6ce2\u7eb9\u7ba1<\/td><td>DN32<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u9707\/\u907f\u514d\u4e3b\u673a\u5bf9\u7ba1\u9053\u9600\u95e8\u4ea7\u751f\u9707\u52a8\u53d1\u58f0<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u5b89\u5168\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7cfb\u7edf\u6c34\u538b\/\u907f\u514d\u8bbe\u5907\u9600\u95e8\u53d7\u9ad8\u538b\u635f\u574f<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a\u548c\u7cfb\u7edf\u6700\u5c0f\u5faa\u73af\u6d41\u91cf<\/td><\/tr>\n            <tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u81ea\u52a8\u8865\u6c34\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u8bc1\u7cfb\u7edf\u6c34\u91cf\u5145\u8db3\u63d0\u9ad8\u6548\u7387<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6b63\u53d1<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>40\u76ee\uff0c\u8fc7\u6ee4\u6742\u8d28\uff0c\u4fdd\u8bc1\u7cfb\u7edf\u6b63\u5e38\u8fd0\u884c<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u8bbe\u5907\u914d\u4ef6<\/td><td>\u538b\u529b\u6e29\u5ea6\u8868\/\u5185\u5916\u4e1d\u6d3b\u63a5\u5bf9\u63a5\/\u8865\u82af\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u9600\u95e8\u7ba1\u4ef6\uff0c\u7a33\u5b9a\u7cfb\u7edf\u8fd0\u884c\uff0c\u663e\u793a\u7cfb\u7edf\u538b\u529b\u4fbf\u4e8e\u68c0\u67e5\u7cfb\u7edf\u8fd0\u884c\u72b6\u51b5<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6c34\u6ce5\u7802\u6d46<\/td><td><\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5f00\u69fd\u540e\u8986\u76d6\u4fee\u8865\uff0c\u8ddf\u4e1a\u4e3b\u534f\u5546\u7531\u4e1a\u4e3b\u63d0\u4f9b<\/td><\/tr>\n            <tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b<\/td><td><\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6253\u538b\u6750\u6599\u4e00\u5957<\/td><\/tr>\n            <tr><td>\u65b0\u6caa\/\u65b0\u754c<\/td><td>\u53d8\u9891\u6c34\u6cf5<\/td><td>\u578b\u53f7\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5f53\u91c7\u6696\u7cfb\u7edf\u65e0\u81ea\u5e26\u6c34\u6cf5\u65f6\u9009\u914d<\/td><\/tr>\n            <tr><td>\u65e5\u7acb<\/td><td>\u6c34\u6e29\u63a7\u5236\u5668<\/td><td>PC-WHM2Q\/PC-WHM3Q<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6839\u636e\u4e0d\u540c\u7cfb\u5217\u8981\u6c42\u9009\u914d\uff0c\u8c03\u8282\u91c7\u6696\u6c34\u6e29<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>2*1.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u63a7\u5236\u7ebf<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>PVC\u5957\u7ba1<\/td><td>\u03c616<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c(\u53ef\u9009)<\/td><td>\u7eaf\u94dd\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u7eff\u7fbd<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td><\/tr>\n            <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u8f85\u6599<\/td><td>\u5361\u9489.\u767d\u4e73\u80f6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u56fa\u5b9a\u5730\u6696\u76d8\u7ba1\u548c\u53cd\u5c04\u819c<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d\u7b49<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u76d1\u7406\u670d\u52a1\uff0c\u5305\u62ec\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr>\n            <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u542b\u8bbe\u5907\u5b89\u88c5\u3001\u5899\u4f53\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u8d39\u7528\uff1b\u8bbe\u5907\u8d28\u4fdd\u671f\u4e3a\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u6574\u673a60\u4e2a\u6708\uff0c6\u4e2a\u6708\u4e3a\u88c5\u4fee\u671f\uff09\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e2d\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u8f85\u6750\u6570\u91cf\u7684\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u7a7a\u8c03\u914d\u7535\u7bb1\u3001\u4ee5\u53ca\u4ece\u4e3b\u673a\u5230\u914d\u7535\u7bb1\u7684\u7535\u6e90\u7ebf\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u5ba4\u5916\u673a\u57fa\u7840\u3001\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u539f\u59cb\u5730\u9762\uff08\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm\uff09\u3001\u5899\u9762\u3001\u84c4\u70ed\u5c42\u5904\u7406\uff0c\u5982\u9700\u91cd\u63ed\u5730\u576a\uff0c\u627e\u5e73\uff0c\u8c03\u9ad8\u5dee\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\uff1b\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/div>\n        <div class=\"clause\">\u5982\u679c\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u8981\u52a8\u7528\u673a\u68b0\u8bbe\u5907\u540a\u88c5\uff0c\u8d39\u7528\u6309\u6211\u516c\u53f8\u6536\u8d39\u6807\u51c6\u6536\u53d6\uff0c\u6216\u7532\u65b9\u81ea\u884c\u540a\u88c5\u81f3\u6307\u5b9a\u4f4d\u7f6e\u3002<\/div>\n        <div class=\"clause\">\u88c5\u4fee\u65b9\u8d1f\u8d23\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03\u6c34\u7cfb\u7edf\u8865\u6c34\uff0c\u5373\u63d0\u4f9b\u4e00\u6839\u81ea\u6765\u6c34\u7ba1\u5e76\u52a0\u88c5\u9600\u95e8\u81f3\u6211\u65b9\u6307\u5b9a\u4f4d\u7f6e\u3002<\/div>\n        <div class=\"clause\">\u5ba4\u5185\u673a\u9001\u3001\u56de\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7531\u7532\u65b9\u6728\u5de5\u5f00\u5b54\uff0c\u6240\u6709\u7684\u5c3a\u5bf8\u5747\u7531\u6211\u516c\u53f8\u73b0\u573a\u65bd\u5de5\u4eba\u5458\u63d0\u4f9b\u3002<\/div>\n        <div class=\"clause\">\u7a7a\u8c03\u5185\u673a\u51fa\u98ce\u65b9\u5f0f\u4e3a\u4fa7\u51fa\u4e0b\u56de\uff0c\u5982\u9700\u589e\u52a0\u98ce\u9053\u6309150\u5143\/\u5e73\u65b9\u7c73\u53e6\u8ba1\uff1b\u98ce\u53e3\u6309\u7167\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u5982\u9700\u52a0\u957f\u6309150\u5143\/m\u53e6\u8ba1\uff0c\u4e0d\u8db3\u4e00\u7c73\u6309\u7167\u4e00\u7c73\u8ba1\u7b97\uff1b\u5916\u673a\u7ba1\u9053\u82e5\u52a0\u88c5\u9970\u6263\u69fd\u6309110\u5143\/m\u53e6\u8ba1\u3002<\/div>\n        <div class=\"clause\">\u5730\u6696\u6309\u7167\u7532\u65b9\u8981\u6c42\u8bbe\u8ba1\uff1a\u5ba4\u6e2918\u2103~22\u2103\uff1b\u5730\u6696\u623f\u95f4\u5982\u91c7\u7528\u6728\u5730\u677f\u65f6\uff0c\u9700\u9009\u62e9\u5730\u6696\u4e13\u7528\u6728\u5730\u677f\uff0c\u4e14\u4e00\u5b9a\u4e0d\u8981\u94fa\u8bbe\u9632\u6f6e\u57ab\uff0c\u5426\u5219\u5f71\u54cd\u5730\u6696\u6563\u70ed\u6548\u679c\u7531\u7532\u65b9\u6216\u6728\u5730\u677f\u65bd\u5de5\u65b9\u8d1f\u8d23\u3002<\/div>\n        <div class=\"clause\">\u536b\u751f\u95f4\u3001\u53a8\u623f\u3001\u9633\u53f0\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u82e5\u94fa\u8bbe\u6709\u91c7\u6696\u7ba1\u9053\uff0c\u9700\u8981\u5728\u5730\u6696\u4e0a\u53ca\u5730\u6696\u4e0b\u5de5\u4f5c\u4e24\u6b21\u9632\u6c34\uff1b\u9632\u6c34\u8d39\u7528\u4e0d\u5305\u542b\u5728\u672c\u9884\u7b97\u8303\u56f4\u5185\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u6709\u6548\u671f30\u5929\uff0c\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/div>\n\n        <h4>\u65b0\u98ce\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u9644\u8868B \u00b7 \u5929\u51c0\u65b0\u98ce350\uff09<\/h4>\n        <table class=\"tbl\">\n          <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td>\u65e5\u7acb<\/td><td>\u5929\u51c0\u65b0\u98ce350<\/td><td>KPI-3521Q5\/F<\/td><td>1\u53f0<\/td><td>\u5168\u70ed\u4ea4\u6362\/\u51c0\u5316\/\u6052\u6c27\uff0c\u4ee5\u4e8c\u5c42\u5367\u5ba4\u98ce\u91cf\u4e3a\u4e3b<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>PE\u6ce2\u7eb9\u7ba1<\/td><td>\u03c6110\/\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6750\u8d28\u73af\u4fdd\u65e0\u83cc\/\u6297\u51b2\u51fb\u6027\u548c\u8010\u8150\u8680\u6027\u80fd\u597d<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>\u4e3b\u673a\u8fde\u63a5\u7ba1<\/td><td>\u03c6110<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5bc6\u5c01\u9632\u5c18\uff0c\u6709\u6548\u964d\u566a<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>\u76f4\u63a5\/\u53d8\u5f84\/\u4e09\u901a<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u8fde\u63a5\u4ef6<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>PE\u7ba1\u62b1\u5361<\/td><td>\u03c6110\/\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u7ba1<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3<\/td><td>\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>ABS\u4f18\u8d28\u6750\u6599\u65cb\u8f6c\u53ef\u8c03\u8282\/\u7b80\u7ea6\u7cbe\u7f8e<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3\u5957\u4ef6<\/td><td>\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>ABS\u4f18\u8d28\u6750\u6599\u767d\u8272\u53cc\u5957\u5361\u4ef6\/\u906e\u853d\u5b54\u6d1e<\/td><\/tr>\n            <tr><td>\u771f\u5982<\/td><td>\u9632\u96e8\u98ce\u7f69<\/td><td>\u03c6120<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>304\u4e0d\u9508\u94a2\u9632\u96e8\u5916\u98ce\u7f69\u62e6\u622a\u6811\u53f6\u4ee5\u53ca\u6742\u7269<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u65b0\u98ce\u5b89\u88c5\u8c03\u8bd5<\/td><td>\u65b0\u6392\u98ce\u6811\u72b6\u5b89\u88c5<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u6280\u5e08\u56e2\u961f\u670d\u52a1\u6d41\u7a0b\u5347\u7ea7<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u65b0\u98ce\u4e3b\u673a\u7684\u7535\u6e90\u7ebf\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u65bd\u5de5\u7528\u6c34\u7535\u8d39\u3002<\/div>\n        <div class=\"clause\">\u4e0d\u542b\u5f00\u7968\uff0c\u4e0d\u542b\u8fdc\u7a0b\u8d39\u3002<\/div>\n        <div class=\"clause\">\u4e0d\u542b\u540e\u671f\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7684\u5f00\u53e3\u57fa\u7840\u8d39\u7528\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u53ea\u9650\u4e8e\u6b64\u9879\u76ee\u3002<\/div>\n\n        <h4>\u5730\u6696\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u9644\u8868C \u00b7 130\u33a1\uff0c\u4e09\u65b9\u6848\u901a\u7528\uff09<\/h4>\n        <p><b>\u9002\u7528\u7cfb\u7edf<\/b>\uff1a\u72ec\u7acb\u5730\u6696\u7cfb\u7edf\uff08\u71c3\u6c14\u58c1\u6302\u7089\u6216\u7a7a\u6c14\u80fd\u70ed\u6e90\uff0c\u672c\u65b9\u6848\u4e3a160\u6c34\u6a21\u5757\/\u83f2\u65af\u66fc\u9505\u7089\u5e26\u5730\u6696\uff09<\/p>\n        <table class=\"tbl\">\n          <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u578b\u53f7\u548c\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td>\u4f1f\u661f<\/td><td>F-PPR\u7ea4\u7ef4\u590d\u5408\u7ba1<\/td><td>De32*4.4\/De40*5.5\/De50*6.9<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr>\n            <tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d832\/\u00d840\/\u00d850<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u6e29\u7ba1\/\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr>\n            <tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d825<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29\uff0c\u964d\u4f4e\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PPR\u89d2\u5f0f\u7403\u9600<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u5206\u96c6\u6c34\u5668\u6c34\u6d41\uff0c\u65b9\u4fbf\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u94dc\u8d28\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\uff0c\u5206\u8def\u63a7\u5236<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668\u672b\u7aef\u5c3e\u4ef6<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14\u9600+\u6cc4\u6c34\u9600+\u538b\u529b\u8868<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\uff0c\u76f4\u63a5\uff0c\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053\u4e0e\u9600\u95e8<\/td><\/tr>\n            <tr><td>\u5a01\u5c14\u9f99<\/td><td>\u6c34\u529b\u5206\u538b\u5668<\/td><td>DN25<\/td><td>1\u9879<\/td><td>\u5f53\u5730\u6696\u505a\u4e8c\u6b21\u7cfb\u7edf\u65f6\uff0c\u9700\u642d\u914d<\/td><\/tr>\n            <tr><td>\u5fb7\u56fd\u5a01\u4e50<\/td><td>\u6c34\u6cf5<\/td><td>Wilo-RS25\/8<\/td><td>1\u9879<\/td><td>\u5f53\u5730\u6696\u505a\u4e8c\u6b21\u7cfb\u7edf\u65f6\uff0c\u9700\u642d\u914d<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1dn20(\u9ed8\u8ba4)<\/td><td>PE-RT dn20*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u4e94\u5c42\u963b\u6c27\u5730\u6696\u7ba1dn20(\u53ef\u9009)<\/td><td>PE-RT dn20*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1dn16(\u53ef\u9009)<\/td><td>PE-RT dn16*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u4e94\u5c42\u963b\u6c27\u5730\u6696\u7ba1dn16(\u53ef\u9009)<\/td><td>PE-RT dn16*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c(\u53ef\u9009)<\/td><td>\u7eaf\u94dd\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u7eff\u7fbd<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6599<\/td><td>\u9002\u914d\u89c4\u683c<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5ef6\u5899\u4fdd\u6e29\u6761\/\u4f38\u7f29\u7f1d\/\u62a4\u5957\u7ba1\/\u94dd\u7b94\u80f6\u5e26\/\u80f6\u6c34\/\u5361\u9489<\/td><\/tr>\n            <tr><td>\u8ba2\u8d2d<\/td><td>\u5f2f\u7ba1\u5957<\/td><td>\u00d820\/\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5206\u96c6\u6c34\u5668\u5730\u6696\u5f2f\u7ba1\u5904\u4fdd\u62a4<\/td><\/tr>\n            <tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b\u6750\u6599\u4e00\u5957<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u68c0\u6d4b\u7cfb\u7edf\u538b\u529b<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6c34\u6ce5\u7802\u6d46<\/td><td>\/<\/td><td>\/<\/td><td>\u4e3b\u7ba1\u5f00\u69fd\u540e\u8986\u76d6\u4fee\u8865(\u82e5\u6709)\uff0c\u8ddf\u4e1a\u4e3b\u534f\u5546\u7531\u4e1a\u4e3b\u63d0\u4f9b<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u9505\u7089\u63a7\u5236\u5668<\/td><td><\/td><td><\/td><td>\u5730\u6696\u603b\u63a7\u7cfb\u7edf<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u5ba4\u6e29\u63a7\u5236\u5668<\/td><td>RT1.23i<\/td><td>\u4e0e\u623f\u95f4\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u6c34\u91c7\u6696+\u8054\u52a8+WiFi<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>SEH35.23<\/td><td>\u4e0e\u56de\u8def\u6570\u76f8\u540c<\/td><td>AC220V\uff0c\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>3*0.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u6e29\u63a7\u5668\/\u7535\u70ed\u6267\u884c\u5668\/\u9505\u7089<\/td><\/tr>\n            <tr><td>\u5ddd\u8def<\/td><td>PVC\u7ebf\u7ba1<\/td><td>\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u53ca\u7535\u6e90\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u8054\u52a8\u63a7\u5236(\u9ed8\u8ba4)<\/td><td>H-BOX<\/td><td>1\u9879<\/td><td>\u5ba4\u6e29\u8054\u52a8\u9505\u7089\u542f\u505c\uff0c\u8fbe\u5230\u8282\u80fd\u7684\u6548\u679c<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\/\u51fa\u56fe\/\u5b9a\u4f4d\/\u6d3e\u5355\u7b49<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u76d1\u7406\u670d\u52a1\uff0c\u5305\u62ec\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr>\n            <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <div class=\"clause\">\u9505\u7089\u6240\u9700\u7684\u6c34\u3001\u7535\u3001\u6c14\u63a5\u53e3\uff0c\u987b\u7531\u4e1a\u4e3b\u8d1f\u8d23\u534f\u8c03\u71c3\u6c14\u3001\u88c5\u9970\u516c\u53f8\u9884\u7559\u5230\u4e09\u65b9\u73b0\u573a\u4ea4\u5e95\u540e\u7684\u6307\u5b9a\u4f4d\u7f6e\u3002<\/div>\n        <div class=\"clause\">\u672c\u9884\u7b97\u4e0d\u5305\u542b\u539f\u59cb\u5730\u9762\uff08\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm\uff09\u3001\u5899\u9762\u5904\u7406\u3002\u5982\u9700\u91cd\u63ed\u5730\u576a\u3001\u627e\u5e73\u3001\u8c03\u9ad8\u5dee\u3001\u5783\u573e\u6e05\u8fd0\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/div>\n        <div class=\"clause\">\u9505\u7089\u70df\u7ba1\u6807\u914d\u4e3a0.8\u7c73\uff0c\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u4e3a\u786e\u4fdd\u9505\u7089\u5b89\u5168\u8fd0\u884c\uff0c\u6240\u9700\u52a0\u957f\u70df\u7ba1\uff0c\u5f2f\u5934\u7b49\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/div>\n        <div class=\"clause\">\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u6696\u6c14\u7247\u5b89\u88c5\u8fc7\u7a0b\u4e2d\u5982\u9700\u589e\u52a0\u5730\u652f\u67b6\uff0c\u8be5\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/div>\n        <div class=\"clause\">\u536b\u751f\u95f4\uff0c\u53a8\u623f\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u82e5\u94fa\u8bbe\u6709\u91c7\u6696\u7ba1\u9053\uff0c\u9700\u8981\u5728\u5730\u6696\u4e0a\u53ca\u5730\u6696\u4e0b\u5de5\u4f5c\u4e24\u6b21\u9632\u6c34\u3002\u9632\u6c34\u8d39\u7528\u4e0d\u5305\u542b\u5728\u672c\u9884\u7b97\u8303\u56f4\u5185\u3002<\/div>\n        <div class=\"clause\">\u975e\u6211\u53f8\u539f\u56e0\u9020\u6210\u66f4\u6539\u5df2\u7ecf\u5b89\u88c5\u597d\u7684\u9505\u7089\u3001\u6696\u6c14\u7247\u3001\u5206\u6c34\u7bb1\u3001\u7ba1\u9053\u4f4d\u7f6e\uff0c\u9700\u53e6\u884c\u6536\u53d6\u76f8\u5173\u6539\u52a8\u8d39\u7528\u3002<\/div>\n        <div class=\"clause\">\u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002<\/div>\n        <div class=\"clause\">\u672c\u9884\u7b97\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/div>\n      <\/div>\n    <\/details>\n\n    <!-- \u65b9\u6848\u4e8c\uff1aF + B\uff08\u5730\u6696\u540cC\uff09 -->\n    <details class=\"annex\">\n      <summary>\u65b9\u6848\u4e8c \u00b7 \u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e8c\u8054\u4f9b \u2014\u2014 \u9644\u8868F\uff08\u6c34\u673a\u4e24\u8054\u4f9b\uff09+ \u9644\u8868B\uff08\u65b0\u98ce\uff09+ \u9644\u8868C\uff08\u5730\u6696\uff0c\u540c\u4e0a\uff09<\/summary>\n      <div class=\"acont\">\n        <h4>\u6c34\u673a\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u9644\u8868F \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\uff09<\/h4>\n        <p><b>\u9002\u7528\u7cfb\u7edf<\/b>\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u7cfb\u5217\uff08\u5929\u6c34\u5730\u6c34\uff09<\/p>\n        <table class=\"tbl\">\n          <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u7b49\u4e8e\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u6c34\u673a\u7a7a\u8c03\u4e13\u7528\u7ba1(\u4e3b\u7ba1)<\/td><td>dn40*en3.7\/dn50*en4.6\/dn63*en5.8<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u6c34\u673a\u7a7a\u8c03\u4e13\u7528\u7ba1(\u652f\u7ba1)<\/td><td>dn32*en2.9\/dn25*en2.3<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u8fd0\u8f93\u7ba1\u9053\u4f20\u9012\u51b7\u91cf\u6216\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u4e3b\u7ba1)<\/td><td>\u03c640*20\/\u03c650*20\/\u03c663*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9\/\u7ba1\u9053\u4fdd\u6e29\u9632\u6b62\u7ed3\u9732<\/td><\/tr>\n            <tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u652f\u7ba1)<\/td><td>\u03c632*20\/\u03c625*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29\u9632\u6b62\u7ed3\u9732<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>UPVC\u51b7\u51dd\u6c34\u7ba1\u53ca\u4fdd\u6e29\u8f85\u6599<\/td><td>\u9002\u914d\u578b\u53f7<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u653e\u51b7\u51dd\u6c34\uff0c\u9632\u6b62\u7ed3\u9732<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\u3001\u76f4\u63a5\u3001\u5927\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7403\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u6d3b\u63a5\u9600\u95e8\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u622a\u6b62\u9600<\/td><td>DN32<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td><\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u4e8c\u901a\u9600\uff08\u9632\u7ed3\u57a2\u9632\u6c34\uff09<\/td><td>FK30.20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5207\u65ad\u672b\u7aef\u6c34\u6d41\uff0c\u5206\u533a\u8c03\u8282<\/td><\/tr>\n            <tr><td>\u65e5\u7acb\u6807\u914d<\/td><td>\u5b89\u5168\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7cfb\u7edf\u6c34\u538b\uff0c\u907f\u514d\u8bbe\u5907\u9600\u95e8\u53d7\u9ad8\u538b\u635f\u574f<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>DN32<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a\u548c\u7cfb\u7edf\u6700\u5c0f\u5faa\u73af\u6d41\u91cf<\/td><\/tr>\n            <tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u81ea\u52a8\u8865\u6c34\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u8bc1\u7cfb\u7edf\u6c34\u91cf\u5145\u8db3\u63d0\u9ad8\u6548\u7387<\/td><\/tr>\n            <tr><td>\u65e5\u7acb\u6807\u914d<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fc7\u6ee4\u6742\u8d28\uff0c\u4fdd\u8bc1\u7cfb\u7edf\u6b63\u5e38\u8fd0\u884c<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u91d1\u5c5e\u6ce2\u7eb9\u7ba1<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u7ba1\u9053\uff0c\u51cf\u9707\uff0c\u907f\u514d\u5bf9\u7ba1\u9053\u9600\u95e8\u4ea7\u751f\u9707\u52a8\u53d1\u58f0<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u91d1\u5c5e\u6ce2\u7eb9\u7ba1<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td><\/td><\/tr>\n            <tr><td>\u65bd\u8010\u5fb7<\/td><td>\u7ee7\u7535\u5668<\/td><td>RXM<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6c34\u6cf5\u4e2d\u7ee7\u63a7\u5236<\/td><\/tr>\n            <tr><td>\u65b0\u6caa\/\u65b0\u754c<\/td><td>\u53d8\u9891\u6c34\u6cf5<\/td><td>\u578b\u53f7\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u53d8\u9891\u7cfb\u7edf\u4e00\u5957<\/td><\/tr>\n            <tr><td>\/<\/td><td>\u81a8\u80c0\u7f50<\/td><td>8L<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5438\u7eb3\u7cfb\u7edf\u4e2d\u7684\u6c34\u53d7\u70ed\u540e\u589e\u52a0\u7684\u4f53\u79ef<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u8bbe\u5907\u914d\u4ef6<\/td><td>\u6e29\u538b\u8868\/\u6d3b\u63a5\/\u8865\u82af\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u4ef6\/\u4fbf\u4e8e\u68c0\u67e5\u7cfb\u7edf\u8fd0\u884c\u72b6\u51b5<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u540a\u5361\uff08\u914d\u62b1\u7b8d\uff09<\/td><td>\u9002\u914d\u578b\u53f7<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u51b7\u5a92\u7ba1\u548c\u51b7\u51dd\u7ba1<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6750<\/td><td>\u751f\u6599\u5e26\u3001\u4e1d\u6746\u3001\u578b\u94a2\u3001\u81a8\u80c0\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u56fa\u5b9a\u7ba1\u9053\u4e0e\u8bbe\u5907<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>RVVP<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ebf\u63a7\u5668\u4e0e\u5185\u673a\u4e4b\u95f4\u901a\u8baf<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>RVVP<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u5185\u673a\u4e4b\u95f4\u5230\u5916\u673a\u901a\u8baf<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>BV<\/td><td>3*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5185\u673a\u7535\u6e90\u7ebf<\/td><\/tr>\n            <tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>PVC\u7ebf\u7ba1\u53ca\u914d\u4ef6<\/td><td>\u03c616<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u53ca\u7535\u6e90\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c42\u697c\u4e00\u4e2a<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\u3001\u5206\u8def\u63a7\u5236\uff0c\u6392\u6c14\u6392\u6c61\u9600\u4fbf\u4e8e\u7cfb\u7edf\u68c0\u4fee\u548c\u7ef4\u62a4<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u9002\u914d\u4e00\u4f53\u89d2\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u5916\u4e1d\u5bf9\u63a5<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u9600\u95e8\u4e0e\u8bbe\u5907<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u4e8c\u901a\u9600<\/td><td>FK30.20<\/td><td>\u6bcf\u5c42\u697c\u4e00\u4e2a<\/td><td>\u5207\u65ad\u672b\u7aef\u6c34\u6d41\uff0c\u8d77\u5230\u7cfb\u7edf\u8282\u80fd\u548c\u9632\u6b62\u51b7\u6c34\u8fdb\u5165\u5730\u9762\u9020\u6210\u7ed3\u9732<\/td><\/tr>\n            <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c(\u53ef\u9009)<\/td><td>\u7eaf\u94dd\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n            <tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u7eff\u7fbd<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr>\n            <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td><\/tr>\n            <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u8f85\u6599<\/td><td>\u5361\u9489.\u767d\u4e73\u80f6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u56fa\u5b9a\u5730\u6696\u76d8\u7ba1\u548c\u53cd\u5c04\u819c<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d\u7b49<\/td><\/tr>\n            <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u76d1\u7406\u670d\u52a1\uff0c\u5305\u62ec\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr>\n            <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u7a7a\u8c03\u914d\u7535\u7bb1\u3001\u4ee5\u53ca\u4ece\u4e3b\u673a\u5230\u914d\u7535\u7bb1\u7684\u7535\u6e90\u7ebf\uff0c\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/div>\n        <div class=\"clause\">\u7a7a\u8c03\u68c0\u4fee\u53e3\u7531\u88c5\u4fee\u4e13\u4e1a\u8d1f\u8d23\u5f00\u53e3\u4e14\u68c0\u4fee\u53e3\u7531\u88c5\u9970\u4e13\u4e1a\u5236\u4f5c\u5b89\u88c5\uff0c\u6240\u6709\u7684\u5c3a\u5bf8\u5747\u7531\u6211\u516c\u53f8\u73b0\u573a\u65bd\u5de5\u4eba\u5458\u63d0\u4f9b\u3002\u5982\u9700\u66f4\u6539\u98ce\u53e3\u5c3a\u5bf8\u9700\u53e6\u884c\u8ba1\u8d39\uff1a150\u5143\/\u7c73\u3002\u88c5\u9970\u6263\u69fd\uff1a110\u5143\/\u7c73\u3002<\/div>\n        <div class=\"clause\">\u88c5\u4fee\u65b9\u8d1f\u8d23\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03\u6c34\u7cfb\u7edf\u8865\u6c34\uff0c\u5373\u63d0\u4f9b\u4e00\u6839\u81ea\u6765\u6c34\u7ba1\u5e76\u52a0\u88c5\u9600\u95e8\u81f3\u6211\u65b9\u6307\u5b9a\u4f4d\u7f6e\u3002<\/div>\n        <div class=\"clause\">\u7532\u65b9\u8d1f\u8d23\u4e3b\u673a\u57fa\u7840\uff0c\u62a5\u4ef7\u4e0d\u5305\u542b\u8bbe\u5907\u7684\u540a\u88c5\u8d39\uff0c\u5982\u6709\u9700\u8981\u8d39\u7528\u6309\u516c\u53f8\u6536\u8d39\u6807\u51c6\u6536\u53d6\uff0c\u6216\u7532\u65b9\u81ea\u884c\u540a\u88c5\u81f3\u6307\u5b9a\u4f4d\u7f6e\u3002<\/div>\n        <div class=\"clause\">\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u98ce\u53e3\u51fa\u98ce\u65b9\u5f0f\u4e3a\u4fa7\u51fa\u4e0b\u56de\uff0c\u5982\u9700\u589e\u52a0\u98ce\u9053\u6309\u6bcf\u5e73\u65b9150\u5143\u53e6\u884c\u8ba1\u7b97\u3002<\/div>\n        <div class=\"clause\">\u5730\u6696\uff1a\u6309\u7167\u7532\u65b9\u8981\u6c42\u8bbe\u8ba1\uff1b\u5ba4\u6e29\u8bbe\u8ba1\u4f9d\u636e18\u2103~22\u2103\u3002<\/div>\n        <div class=\"clause\">\u672c\u9884\u7b97\u4e0d\u5305\u542b\u539f\u59cb\u5730\u9762(\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm)\u548c\u5899\u9762\u5904\u7406\u53ca\u84c4\u70ed\u5c42\u3002\u5982\u9700\u91cd\u63ed\u5730\u576a\uff0c\u627e\u5e73\uff0c\u8c03\u9ad8\u5dee\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/div>\n        <div class=\"clause\">\u536b\u751f\u95f4\u3001\u53a8\u623f\u3001\u9633\u53f0\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u623f\u5c4b\uff0c\u5982\u9700\u5b89\u88c5\u7ba1\u8def\u53ca\u5206\u6c34\u7bb1\u7b49\u91c7\u6696\u8bbe\u5907\uff0c\u5219\u623f\u5c4b\u5730\u9762\u7684\u9632\u6c34\u7531\u7532\u65b9\u8d1f\u8d23\u91cd\u505a\u3002<\/div>\n        <div class=\"clause\">\u5982\u91c7\u7528\u6728\u5730\u677f\u65f6\uff0c\u4e00\u5b9a\u4e0d\u8981\u94fa\u8bbe\u9632\u6f6e\u57ab\uff0c\u5426\u5219\u5f71\u54cd\u5730\u6696\u6563\u70ed\u6548\u679c\u7531\u7532\u65b9\u6216\u6728\u5730\u677f\u65bd\u5de5\u65b9\u8d1f\u8d23\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u7a0e\u91d1\u3001\u8fdc\u7a0b\u65bd\u5de5\u8d39\u3002<\/div>\n        <div class=\"clause\">\u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002<\/div>\n        <div class=\"clause\">\u672c\u9884\u7b97\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/div>\n        <p class=\"note\">\u65b0\u98ce\uff08\u9644\u8868B\uff09\u4e0e\u5730\u6696\uff08\u9644\u8868C\uff09\u540c\u65b9\u6848\u4e00\uff0c\u8be6\u89c1\u4e0a\u65b9\u300c\u65b9\u6848\u4e00\u300d\u6298\u53e0\u5185\u5bf9\u5e94\u9644\u8868\uff0c\u54c1\u724c\u89c4\u683c\u4e00\u81f4\u3001\u4e0d\u91cd\u590d\u7f57\u5217\u3002<\/p>\n      <\/div>\n    <\/details>\n\n    <!-- \u65b9\u6848\u4e09\uff1aA + B\uff08\u5730\u6696\u540cC\uff09 -->\n    <details class=\"annex\">\n      <summary>\u65b9\u6848\u4e09 \u00b7 \u8212\u4eab\u6c1f\u673a+\u83f2\u65af\u66fc\u9505\u7089 \u2014\u2014 \u9644\u8868A\uff08\u7eaf\u6c1f\u4e2d\u592e\u7a7a\u8c03\uff09+ \u9644\u8868B\uff08\u65b0\u98ce\uff09+ \u9644\u8868C\uff08\u5730\u6696\uff0c\u540c\u4e0a\uff09<\/summary>\n      <div class=\"acont\">\n        <h4>\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u9644\u8868A \u00b7 \u7eaf\u6c1f\u7cfb\u7edf\uff09<\/h4>\n        <p><b>\u9002\u7528\u7cfb\u7edf<\/b>\uff1a\u8212\u4eab\u7cfb\u5217\u3001VAM mini\u7cfb\u5217\u3001\u5c0a\u777f\u7cfb\u5217\u3001\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff08\u7eaf\u6c1f\u7cfb\u7edf\uff09<\/p>\n        <table class=\"tbl\">\n          <thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr><\/thead>\n          <tbody>\n            <tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u7b49\u4e8e\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr>\n            <tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr>\n            <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr>\n            <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr>\n            <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5bf9\u51b7\u5a92\u8fdb\u884c\u5206\u914d<\/td><\/tr>\n            <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><\/tr>\n            <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n            <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>\u539a\u5ea620mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n            <tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea6\u4e3a15mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u540a\u5361<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u5361\uff08\u914d\u62b1\u7b8d\uff09<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u7ba1\u8def\u5b89\u88c5\uff0c\u5347\u7ea7\u5de5\u827a<\/td><\/tr>\n            <tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6750<\/td><td>\u4e1d\u6760\u3001\u81a8\u80c0\u3001\u51cf\u9707\u57ab\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u5b89\u88c5\u56fa\u5b9a<\/td><\/tr>\n            <tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr>\n            <tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr>\n            <tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\u7b49<\/td><\/tr>\n            <tr><td>\u9f99\u8109<\/td><td>\u8fd0\u8f93\u8d39<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td><\/td><\/tr>\n          <\/tbody>\n        <\/table>\n        <div class=\"clause\">\u542b\u8bbe\u5907\u5b89\u88c5\uff0c\u5899\u4f53\u5f00\u5b54\uff0c\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u8d39\u7528\u3002\u8bbe\u5907\u8d28\u4fdd\u671f\u4e3a\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u6574\u673a60\u4e2a\u6708\uff0c6\u4e2a\u6708\u4e3a\u88c5\u4fee\u671f\uff09\u3002<\/div>\n        <div class=\"clause\">\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u8f85\u6750\u6570\u91cf\u7684\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u4e0d\u542b\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u571f\u5efa\uff1b\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/div>\n        <div class=\"clause\">\u5982\u679c\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u8981\u52a8\u7528\u673a\u68b0\u8bbe\u5907\uff0c\u540a\u88c5\u8d39\u7528\u6839\u636e\u60c5\u51b5\u53e6\u8ba1\u3002<\/div>\n        <div class=\"clause\">\u5ba4\u5185\u673a\u9001\u3001\u56de\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7531\u7532\u65b9\u6728\u5de5\u5f00\u5b54\uff0c\u4e59\u65b9\u8d1f\u8d23\u63d0\u4f9b\u5f00\u5b54\u5c3a\u5bf8\u548c\u5b89\u88c5\uff0c\u98ce\u53e3\u91c7\u7528\u7edf\u4e00\u5c3a\u5bf8\u3002<\/div>\n        <div class=\"clause\">\u65b9\u6848\u6309\u7167\u4fa7\u51fa\u4e0b\u56de\u98ce\u8bbe\u8ba1\uff0c\u5982\u679c\u505a\u4e0b\u51fa\u98ce\uff0c\u6309150\u5143\/\u5e73\u65b9\u7c73\u6210\u54c1\u98ce\u7ba1\u53e6\u8ba1\u3002<\/div>\n        <div class=\"clause\">\u62a5\u4ef7\u98ce\u53e3\u6309\u7167\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u5982\u9700\u52a0\u957f\u6309150\u5143\/m\u53e6\u8ba1\uff0c\u4e0d\u8db3\u4e00\u7c73\u6309\u7167\u4e00\u7c73\u8ba1\u7b97\uff0c\u5916\u673a\u7ba1\u9053\u6263\u69fd\u6309100\u5143\/m\u53e6\u8ba1\u3002<\/div>\n        <div class=\"clause\">\u5efa\u8bae\u540a\u9876\u4e0d\u505a\u53cd\u5149\u706f\u69fd\uff0c\u53cd\u5149\u706f\u69fd\u5f71\u54cd\u5236\u51b7\u3001\u5236\u70ed\u6548\u679c\uff0c\u8dc3\u5c42\u548c\u5c42\u9ad8\u8d85\u8fc7\u4e09\u7c73\u5236\u70ed\u6548\u679c\u6b20\u4f73\u3002\u5982\u679c\u4fdd\u7559\u706f\u69fd\u8bbe\u8ba1\uff0c\u5efa\u8bae\u4f7f\u7528\u706f\u69fd\u4e13\u7528\u673a\u3002<\/div>\n        <div class=\"clause\">\u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a\u4e00\u4e2a\u6708\u3002\u5982\u6709\u9057\u6f0f\uff0c\u53cc\u65b9\u534f\u5546\u3002<\/div>\n        <p class=\"note\">\u65b0\u98ce\uff08\u9644\u8868B\uff09\u4e0e\u5730\u6696\uff08\u9644\u8868C\uff09\u540c\u65b9\u6848\u4e00\uff0c\u8be6\u89c1\u4e0a\u65b9\u300c\u65b9\u6848\u4e00\u300d\u6298\u53e0\u5185\u5bf9\u5e94\u9644\u8868\uff0c\u54c1\u724c\u89c4\u683c\u4e00\u81f4\u3001\u4e0d\u91cd\u590d\u7f57\u5217\u3002<\/p>\n      <\/div>\n    <\/details>\n    <div class=\"note\">\u8f85\u6750\u6e05\u5355\u751f\u6210\u89c4\u5219\uff08\u6307\u4ee406\uff09\uff1a\u5168\u90e8\u9ed8\u8ba4\u89c4\u683c\u3001\u54c1\u724c\u552f\u4e00\u5408\u6cd5\u4e0d\u66ff\u6362\u3001\u4e0d\u8f93\u51fa\u4efb\u4f55\u4ef7\u683c\u4e0e\u65bd\u5de5\u6307\u5bfc\u3001\u591a\u7cfb\u7edf\u6309\u300c\u7a7a\u8c03 \/ \u65b0\u98ce \/ \u5730\u6696\u300d\u987a\u5e8f\u3002\u5982\u9500\u552e\u4eba\u5458\u660e\u786e\u6307\u5b9a\u5347\u7ea7\u53ef\u9009\u8f85\u6750\uff0c\u5c06\u66ff\u6362\u5bf9\u5e94\u884c\u5e76\u6807\u6ce8\u300c\u5ba2\u6237\u9009\u914d\u5347\u7ea7\u300d\u3002<\/div>\n  <\/div>\n<\/section>\n\n<footer>\n  <div class=\"wrap\">\n    \u9f99\u8109\u6696\u901a \u00b7 \u5357\u5bcc\u68ee\u65d7\u8230\u5e97 028-86131795 \/ \u5317\u5bcc\u68ee\u5e97 028-65272586<br>\n    \u9500\u552e\u987e\u95ee \u4f59\u6653\u73b2\uff08\u4ece\u4e1a22\u5e74\uff09 \u00b7 \u76f4\u7ebf 13008113409<br>\n    \u65b9\u6848\u7f16\u53f7 NFS-WCLD-ZLS-20260801-FA01 \u00b7 \u5bf9\u5185\u65b9\u6848\u6863\u6848\uff08noindex\uff09<br>\n    \u672c\u65b9\u6848\u4e66\u4e3a\u4f9d\u636e\u6307\u4ee406\u4e0e\u6307\u4ee402\u4ef7\u683c\u5e93V5.0\u751f\u6210\u7684\u4e13\u4e1a\u5bf9\u6bd4\u6587\u6863\uff0c\u62a5\u4ef7\u4ee5\u6700\u7ec8\u7b7e\u7ea6\u7248\u4e3a\u51c6 \u00b7 \u4ef7\u683c\u6765\u6e90 page_id=662\n  <\/div>\n<\/footer>\n\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/echarts@5.5.0\/dist\/echarts.min.js\"><\/script>\n<script>\n\/* Tabs *\/\ndocument.querySelectorAll('.tab').forEach(function(t){\n  t.addEventListener('click',function(){\n    document.querySelectorAll('.tab').forEach(x=>x.classList.remove('active'));\n    document.querySelectorAll('.tabpane').forEach(x=>x.classList.remove('active'));\n    t.classList.add('active');\n    document.getElementById(t.dataset.t).classList.add('active');\n  });\n});\n\n\/* \u60ac\u6d6e\u5bfc\u822a\uff1a\u9634\u5f71 + \u5e73\u6ed1\u6eda\u52a8 + \u6eda\u52a8\u9ad8\u4eae + \u5b50\u76ee\u5f55\u4e0b\u62c9 *\/\n(function(){\n  var nav=document.getElementById('topnav');\n  if(!nav) return;\n  var wrap=nav.querySelector('.wrap');\n  var trigger=document.getElementById('menutrigger');\n  var sub=document.getElementById('navsub');\n\n  \/\/ \u4e3b\u76ee\u5f55\uff08\u5ba2\u6237\u6210\u529f5\u6b65\uff09\u951a\u70b9\n  var steps=[].slice.call(wrap.querySelectorAll('a[href^=\"#\"]:not(.navtel)'));\n  \/\/ \u5b50\u76ee\u5f55\uff08\u66f4\u591a\uff09\u951a\u70b9\n  var subs=[].slice.call(sub?sub.querySelectorAll('a'):[]);\n  var allAnchors=steps.concat(subs);\n\n  function navH(){return nav.offsetHeight;}\n\n  \/\/ \u5e73\u6ed1\u6eda\u52a8\uff08\u4e3b\u76ee\u5f55 + \u5b50\u76ee\u5f55\uff09\n  allAnchors.forEach(function(a){\n    a.addEventListener('click',function(e){\n      var href=a.getAttribute('href'); if(href==='#') return;\n      var tgt=document.querySelector(href); if(!tgt) return;\n      e.preventDefault();\n      var y=tgt.getBoundingClientRect().top+window.pageYOffset-navH()+1;\n      window.scrollTo({top:y,behavior:'smooth'});\n      closeSub();\n    });\n  });\n\n  \/\/ \u5b50\u76ee\u5f55\u5f00\u5408\uff08\u684c\u9762 hover \/ \u79fb\u52a8\u7aef click\uff0c\u907f\u514d\u6a2a\u5411\u6eda\u52a8\u6761\u88c1\u5207\uff09\n  var hideTimer=null;\n  function positionSub(){\n    if(!trigger||!sub) return;\n    var r=trigger.getBoundingClientRect(), nr=nav.getBoundingClientRect();\n    var left=r.left-nr.left;\n    var maxLeft=nr.width-sub.offsetWidth-8;\n    if(left>maxLeft) left=maxLeft;\n    if(left<8) left=8;\n    sub.style.left=left+'px'; sub.style.right='auto';\n  }\n  function openSub(){ if(!sub) return; clearTimeout(hideTimer); positionSub(); nav.classList.add('sub-open'); }\n  function closeSub(){ if(!sub) return; nav.classList.remove('sub-open'); }\n  if(trigger){\n    trigger.addEventListener('click',function(e){ e.preventDefault(); nav.classList.contains('sub-open')?closeSub():openSub(); });\n    trigger.addEventListener('mouseenter',openSub);\n    trigger.addEventListener('mouseleave',function(){ hideTimer=setTimeout(closeSub,160); });\n  }\n  if(sub){\n    sub.addEventListener('mouseenter',function(){ clearTimeout(hideTimer); });\n    sub.addEventListener('mouseleave',function(){ hideTimer=setTimeout(closeSub,120); });\n  }\n  document.addEventListener('click',function(e){ if(nav.contains(e.target)) return; closeSub(); });\n  window.addEventListener('resize',function(){ if(nav.classList.contains('sub-open')) positionSub(); });\n\n  \/\/ \u6eda\u52a8\u9ad8\u4eae\uff1a\u5168\u90e8\u951a\u70b9\uff08\u542b\u5b50\u76ee\u5f55\uff09\u6309\u9875\u9762\u987a\u5e8f\u53d6\u6700\u540e\u4e00\u4e2a\u5230\u8fbe\u7684\n  var items=steps.map(function(a){return {a:a,sec:document.querySelector(a.getAttribute('href')),sub:false};})\n    .concat(subs.map(function(a){return {a:a,sec:document.querySelector(a.getAttribute('href')),sub:true};}));\n\n  var ticking=false;\n  function onScroll(){\n    if(window.pageYOffset>10) nav.classList.add('stuck'); else nav.classList.remove('stuck');\n    var pos=window.pageYOffset+navH()+30, activeIdx=-1;\n    items.forEach(function(it,i){ if(it.sec&&it.sec.offsetTop<=pos) activeIdx=i; });\n    steps.forEach(function(a){ a.classList.remove('on'); });\n    subs.forEach(function(a){ a.classList.remove('on'); });\n    if(trigger) trigger.classList.remove('on');\n    if(activeIdx>=0){\n      var it=items[activeIdx];\n      if(it.sub){ if(trigger) trigger.classList.add('on'); }\n      else { it.a.classList.add('on'); }\n    }\n    ticking=false;\n  }\n  window.addEventListener('scroll',function(){\n    if(!ticking){ window.requestAnimationFrame(onScroll); ticking=true; }\n  },{passive:true});\n  onScroll();\n})();\n\n\/* \u89e6\u5c4f\u8bbe\u5907\uff1a\u70b9\u51fb\u7ffb\u8f6c\u5361\u7247 *\/\n(function(){\n  if(!window.matchMedia('(hover:none)').matches) return;\n  document.querySelectorAll('.fcard,.dcard,.geocard').forEach(function(c){\n    c.addEventListener('click',function(e){\n      if(e.target.closest('a')) return;\n      var inner=c.querySelector('.inner')||c.querySelector('.ginner');\n      if(!inner) return;\n      var flipped=inner.style.transform==='rotateY(180deg)';\n      inner.style.transform=flipped?'rotateY(0deg)':'rotateY(180deg)';\n    });\n  });\n})();\n\n\/* 20\u5e74\u603b\u8d26\uff1a\u6309\u94ae\u7ffb\u8f6c\uff08\u4e0d\u7528hover\uff0c\u907f\u514d\u4e0e\u56fe\u8868\u4ea4\u4e92\u51b2\u7a81\uff09 *\/\n(function(){\n  var wrap=document.getElementById('lifeFlip');\n  if(!wrap) return;\n  wrap.querySelectorAll('[data-lflip]').forEach(function(b){\n    b.addEventListener('click',function(){ wrap.classList.toggle('flipped'); });\n  });\n})();\n\n\/* 20\u5e74\u603b\u8d26 \u5806\u53e0\u67f1\u72b6\u56fe\uff08C\u2080 \/ R\u00d720 \/ M\u00d720 \/ \u66f4\u6362\uff09 *\/\n(function(){\n  var el=document.getElementById('lm20Chart');\n  var fb=document.getElementById('lm20Fallback');\n  if(!el || typeof echarts==='undefined') return;   \/* echarts \u4e0d\u53ef\u7528\u65f6\u4fdd\u7559\u9759\u6001\u5806\u53e0\u6761\u515c\u5e95 *\/\n  el.style.display='block';\n  if(fb) fb.style.display='none';\n  var chart20=echarts.init(el);\n  var totals=[190053,202099,210301];\n  chart20.setOption({\n    backgroundColor:'transparent',\n    tooltip:{trigger:'axis',axisPointer:{type:'shadow'},formatter:function(p){\n      var s=String(p[0].axisValue).replace(\/\\n\/g,' ')+'<br\/>',sum=0;\n      p.forEach(function(it){ sum+=it.value; s+=it.marker+it.seriesName+'\uff1a\u00a5'+Math.round(it.value).toLocaleString()+'<br\/>'; });\n      return s+'<b>20\u5e74\u603b\u8d26\uff1a\u00a5'+Math.round(sum).toLocaleString()+'<\/b>';\n    }},\n    legend:{bottom:0,itemWidth:14,itemHeight:9,textStyle:{color:'#6b7480',fontSize:12}},\n    grid:{left:74,right:24,top:34,bottom:52},\n    xAxis:{type:'category',data:['\u65b9\u6848\u4e00 \u5c0a\u777f\u5168\u6548\\n\u5929\u6c1f\u5730\u6c34\u4e94\u6052','\u65b9\u6848\u4e8c \u6c34\u5885\u9002\\n\u5929\u6c34\u5730\u6c34','\u65b9\u6848\u4e09 \u8212\u4eab\\n\uff0b\u83f2\u65af\u66fc\u9505\u7089'],axisLabel:{color:'#102740',fontSize:12,lineHeight:16},axisLine:{lineStyle:{color:'#d7dde5'}}},\n    yAxis:{type:'value',name:'\u5143',nameTextStyle:{color:'#6b7480'},axisLabel:{color:'#6b7480',formatter:function(v){return (v\/10000)+'\u4e07';}},splitLine:{lineStyle:{color:'#e8edf3'}}},\n    series:[\n      {name:'C\u2080 \u521d\u6295\u8d44',type:'bar',stack:'t',barWidth:'42%',data:[106853,104499,89304],itemStyle:{color:'#102740'}},\n      {name:'R \u8fd0\u884c\u8d39\u00d720\u5e74',type:'bar',stack:'t',data:[71200,75600,89400],itemStyle:{color:'#2e5f87'}},\n      {name:'M \u7ef4\u62a4\u8d39\u00d720\u5e74',type:'bar',stack:'t',data:[12000,22000,18000],itemStyle:{color:'#c8a35a'}},\n      {name:'\u66f4\u6362\u6210\u672c',type:'bar',stack:'t',data:[0,0,13597],itemStyle:{color:'#c0792b'},\n        label:{show:true,position:'top',formatter:function(p){return '\u603b\u8d26 '+(totals[p.dataIndex]\/10000).toFixed(2)+'\u4e07';},color:'#102740',fontWeight:'bold',fontSize:12}}\n    ]\n  });\n  window.addEventListener('resize',function(){chart20.resize();});\n  var wrap=document.getElementById('lifeFlip');\n  if(wrap){ wrap.addEventListener('transitionend',function(){ chart20.resize(); }); }\n})();\n<\/script>\n<\/body>\n<\/html>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9e93\u6e56\u4e94\u5f69\u6797\u5824\u4e8c\u8054\u4f9b\u4e94\u6052\u65b9\u6848\u5bf9\u6bd4 | \u9f99\u8109 [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-9303","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u9e93\u6e56\u4e94\u5f69\u6797 130\u33a1\u590d\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u5bf9\u6bd4\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab + \u83f2\u65af\u66fc\u4e09\u5957\u4e8c\u8054\u4f9b\u3002\u6d4b\u7b97\u521d\u6295\u3001\u5e74\u80fd\u8017\u4e0e 20 \u5e74\u603b\u6210\u672c\uff0c\u5929\u6c1f\u5730\u6c34\u6545\u969c\u5c11\u3001\u603b\u8d26\u6700\u4f4e\uff1b\u6c34\u673a\u98ce\u67d4\u7ef4\u62a4\u9ad8\uff1b\u71c3\u6c14\u7089\u521d\u7701\u957f\u671f\u652f\u51fa\u5927\uff0c\u9f99\u8109\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u6807\u51c6\u5316\u65bd\u5de5\uff0c\u5730\u6696\u4eab 50 \u5e74\u8054\u4fdd\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=9303\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9e93\u6e56\u4e94\u5f69\u6797 130\u33a1\u590d\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u5bf9\u6bd4\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab + \u83f2\u65af\u66fc\u4e09\u5957\u4e8c\u8054\u4f9b\u3002\u6d4b\u7b97\u521d\u6295\u3001\u5e74\u80fd\u8017\u4e0e 20 \u5e74\u603b\u6210\u672c\uff0c\u5929\u6c1f\u5730\u6c34\u6545\u969c\u5c11\u3001\u603b\u8d26\u6700\u4f4e\uff1b\u6c34\u673a\u98ce\u67d4\u7ef4\u62a4\u9ad8\uff1b\u71c3\u6c14\u7089\u521d\u7701\u957f\u671f\u652f\u51fa\u5927\uff0c\u9f99\u8109\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u6807\u51c6\u5316\u65bd\u5de5\uff0c\u5730\u6696\u4eab 50 \u5e74\u8054\u4fdd\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=9303\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-01T10:57:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303\",\"name\":\"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\",\"datePublished\":\"2026-08-01T10:50:24+00:00\",\"dateModified\":\"2026-08-01T10:57:31+00:00\",\"description\":\"\u9e93\u6e56\u4e94\u5f69\u6797 130\u33a1\u590d\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u5bf9\u6bd4\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab + \u83f2\u65af\u66fc\u4e09\u5957\u4e8c\u8054\u4f9b\u3002\u6d4b\u7b97\u521d\u6295\u3001\u5e74\u80fd\u8017\u4e0e 20 \u5e74\u603b\u6210\u672c\uff0c\u5929\u6c1f\u5730\u6c34\u6545\u969c\u5c11\u3001\u603b\u8d26\u6700\u4f4e\uff1b\u6c34\u673a\u98ce\u67d4\u7ef4\u62a4\u9ad8\uff1b\u71c3\u6c14\u7089\u521d\u7701\u957f\u671f\u652f\u51fa\u5927\uff0c\u9f99\u8109\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u6807\u51c6\u5316\u65bd\u5de5\uff0c\u5730\u6696\u4eab 50 \u5e74\u8054\u4fdd\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=9303#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","description":"\u9e93\u6e56\u4e94\u5f69\u6797 130\u33a1\u590d\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u5bf9\u6bd4\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab + \u83f2\u65af\u66fc\u4e09\u5957\u4e8c\u8054\u4f9b\u3002\u6d4b\u7b97\u521d\u6295\u3001\u5e74\u80fd\u8017\u4e0e 20 \u5e74\u603b\u6210\u672c\uff0c\u5929\u6c1f\u5730\u6c34\u6545\u969c\u5c11\u3001\u603b\u8d26\u6700\u4f4e\uff1b\u6c34\u673a\u98ce\u67d4\u7ef4\u62a4\u9ad8\uff1b\u71c3\u6c14\u7089\u521d\u7701\u957f\u671f\u652f\u51fa\u5927\uff0c\u9f99\u8109\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u6807\u51c6\u5316\u65bd\u5de5\uff0c\u5730\u6696\u4eab 50 \u5e74\u8054\u4fdd\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=9303","og_locale":"zh_CN","og_type":"article","og_title":"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","og_description":"\u9e93\u6e56\u4e94\u5f69\u6797 130\u33a1\u590d\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u5bf9\u6bd4\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab + \u83f2\u65af\u66fc\u4e09\u5957\u4e8c\u8054\u4f9b\u3002\u6d4b\u7b97\u521d\u6295\u3001\u5e74\u80fd\u8017\u4e0e 20 \u5e74\u603b\u6210\u672c\uff0c\u5929\u6c1f\u5730\u6c34\u6545\u969c\u5c11\u3001\u603b\u8d26\u6700\u4f4e\uff1b\u6c34\u673a\u98ce\u67d4\u7ef4\u62a4\u9ad8\uff1b\u71c3\u6c14\u7089\u521d\u7701\u957f\u671f\u652f\u51fa\u5927\uff0c\u9f99\u8109\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u6807\u51c6\u5316\u65bd\u5de5\uff0c\u5730\u6696\u4eab 50 \u5e74\u8054\u4fdd\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=9303","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-08-01T10:57:31+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"13 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=9303","url":"https:\/\/longmai-nt.com\/?page_id=9303","name":"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=9303#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=9303#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","datePublished":"2026-08-01T10:50:24+00:00","dateModified":"2026-08-01T10:57:31+00:00","description":"\u9e93\u6e56\u4e94\u5f69\u6797 130\u33a1\u590d\u5f0f\u4e94\u6052\u65b9\u6848\uff0c\u5bf9\u6bd4\u5c0a\u777f\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u3001\u8212\u4eab + \u83f2\u65af\u66fc\u4e09\u5957\u4e8c\u8054\u4f9b\u3002\u6d4b\u7b97\u521d\u6295\u3001\u5e74\u80fd\u8017\u4e0e 20 \u5e74\u603b\u6210\u672c\uff0c\u5929\u6c1f\u5730\u6c34\u6545\u969c\u5c11\u3001\u603b\u8d26\u6700\u4f4e\uff1b\u6c34\u673a\u98ce\u67d4\u7ef4\u62a4\u9ad8\uff1b\u71c3\u6c14\u7089\u521d\u7701\u957f\u671f\u652f\u51fa\u5927\uff0c\u9f99\u8109\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u6807\u51c6\u5316\u65bd\u5de5\uff0c\u5730\u6696\u4eab 50 \u5e74\u8054\u4fdd\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=9303#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=9303"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=9303#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=9303#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9e93\u6e56\u4e94\u5f69\u6797\u5824 -\u5f20\u8001\u5e08- \u4e8c\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9303","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=9303"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9303\/revisions"}],"predecessor-version":[{"id":9304,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/9303\/revisions\/9304"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=9303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}