{"id":953,"date":"2026-05-18T17:26:12","date_gmt":"2026-05-18T09:26:12","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=953"},"modified":"2026-05-19T17:15:37","modified_gmt":"2026-05-19T09:15:37","slug":"%e4%ba%91%e7%92%9f%e6%9e%97%e8%91%97%e5%be%90%e5%85%88%e7%94%9f%c2%b7%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e6%96%b0%e9%a3%8e%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=953","title":{"rendered":"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u59d3\u540d<\/strong>\uff1a\u5f90\u5148\u751f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u65e5\u671f<\/strong>\uff1a2026\u5e745\u67083\u65e5<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee\u5730\u5740<\/strong>\uff1a\u53cc\u6d41\u6021\u5fc3\u6e56<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e3b\u673a\u7cfb\u5217<\/strong>\uff1a\u65e5\u7acbEX-\u8212\u4eab\u7cfb\u5217<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9501\u5b9a\u4e3b\u673a<\/strong>\uff1a\u8212\u4eab180\uff08RAS-180HRNAQ\uff0c18.0kW\uff09<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">\u5f90\u5148\u751f \u65e5\u7acb\u7a7a\u8c03\u65b9\u6848\u914d\u7f6e\u4e0e\u62a5\u4ef7<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u2014\u2014\u65b9\u6848\u914d\u7f6e<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u9879\u76ee\u4fe1\u606f<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u9879\u76ee\u5730\u5740\uff1a\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u4e91\u749f\u6797\u845715-2<\/td><td><\/td><\/tr><tr><td>\u5efa\u7b51\u7279\u5f81\uff1a<\/td><td>\u9876\/\u5e95\u5c42\u5efa\u7b51\u25a1 \u4fdd\u6e29\u5efa\u7b51\u25a1 \u897f\u6652\u623f\u95f4\u25a1 \u5927\u7a97\/\u843d\u5730\u73bb\u7483\u25a1 \u6311\u9ad8\u533a\u57df\u25a1 \u4eba\u5458\u6570\u91cf\u25a1 \u540c\u5f00\u7387\u25a1 \u5f00\u7a97\u901a\u98ce\u25a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u8bbe\u8ba1\u4f9d\u636e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b(GB 50736-2012)\u2014\u2014\u5ba4\u5185\u8bbe\u8ba1\u53c2\u6570<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5b63\u8282<\/th><th>\u8bbe\u8ba1\u6e29\u5ea6<\/th><th>\u8bbe\u8ba1\u6e7f\u5ea6<\/th><\/tr><\/thead><tbody><tr><td>\u590f\u5b63<\/td><td>24~26\u2103<\/td><td>40%~60%<\/td><\/tr><tr><td>\u51ac\u5b63<\/td><td>18~22\u2103<\/td><td>\u65e0\u89c4\u5b9a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u300a\u5b9e\u7528\u4f9b\u70ed\u7a7a\u8c03\u8bbe\u8ba1\u624b\u518c\u300b\u51b7\u8d1f\u8377\u8bbe\u8ba1\u53c2\u8003\u503c\uff08\u4ec5\u7528\u4e8e\u521d\u6b65\u4f30\u7b97\u5efa\u7b51\u8d1f\u8377\uff09<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5efa\u7b51\u7c7b\u578b<\/th><th>\u51b7\u8d1f\u8377\u6307\u6807<\/th><\/tr><\/thead><tbody><tr><td>\u9ad8\u5c42\u4f4f\u5b85\uff08\u603b\u697c\u5c42\u6570\u226511\u5c42\uff09<\/td><td>80~120 W\/m\u00b2<\/td><\/tr><tr><td>\u591a\u5c42\u4f4f\u5b85\uff08\u603b\u697c\u5c42\u65704~7\u5c42\uff09<\/td><td>88~150 W\/m\u00b2<\/td><\/tr><tr><td>\u522b\u5885\u7c7b\u4f4f\u5b85\uff081~4\u5c42\u4f4e\u5c42\u72ec\u7acb\u5f0f\u4f4f\u5b85\uff09<\/td><td>150~220 W\/m\u00b2<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7a7a\u8c03\u662f\u5426\u5236\u70ed\uff1a\u662f<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u5ba4\u5185\u673a\u9009\u578b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4\u529f\u80fd<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u53f0\u6570<\/th><th>\u8bbe\u5907\u51b7\u91cf(W)<\/th><th>\u8bbe\u5907\u5c3a\u5bf8(\u9ad8\u00d7\u5bbd\u00d7\u539a mm)<\/th><th>\u8bbe\u8ba1\u51b7\u6307\u6807(W\/m\u00b2)<\/th><th>\u5b9e\u9645\u51b7\u6307\u6807(W\/m\u00b2)<\/th><\/tr><\/thead><tbody><tr><td>\u5e73\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>49<\/td><td>RPIZ-71+40FSNAQD\/P<\/td><td>2<\/td><td>11100<\/td><td>192\u00d71180\u00d7447<\/td><td>180<\/td><td>227<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u4e3b\u5367<\/td><td>15<\/td><td>RPIZ-36FSNAQD\/P<\/td><td>1<\/td><td>3600<\/td><td>192\u00d7700\u00d7447<\/td><td>180<\/td><td>240<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u5973\u513f\u623f<\/td><td>10<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>1<\/td><td>2500<\/td><td>192\u00d7700\u00d7447<\/td><td>180<\/td><td>250<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u8001\u4eba\u623f<\/td><td>10<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1<\/td><td>2200<\/td><td>192\u00d7550\u00d7447<\/td><td>180<\/td><td>220<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u5ba2\u623f<\/td><td>10<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1<\/td><td>2200<\/td><td>192\u00d7550\u00d7447<\/td><td>180<\/td><td>220<\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td><\/td><td><strong>94<\/strong><\/td><td><\/td><td><strong>6<\/strong><\/td><td><strong>21600<\/strong><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u6ce8\uff1a\u8bbe\u5907\u5747\u5177\u5907\u81ea\u6e05\u6d01\u3001\u516d\u6863\u8c03\u901f\u3001\u76f4\u6d41\u53d8\u9891\u3001\u6392\u6c34\u6cf5\u3001\u6d6e\u6c34\u5f00\u5173\u3001\u9664\u6e7f\u7ec4\u4ef6\u30013D\u98ce\u53e3\u3001P\u6a21\u5757\u7b49\u529f\u80fd\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u5ba4\u5916\u673a\u9009\u578b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5ba4\u5916\u673a\u578b\u53f7<\/th><th>\u989d\u5b9a\u5236\u51b7\u91cf(W)<\/th><th>\u989d\u5b9a\u5236\u70ed\u91cf(W)<\/th><th>\u8fde\u63a5\u7387<\/th><th>\u538b\u7f29\u673a<\/th><th>\u8fd0\u8f6c\u8303\u56f4<\/th><th>\u80fd\u6548\u6307\u6807(APF)<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u8bbe\u5907\u5c3a\u5bf8(\u9ad8\u00d7\u5bbd\u00d7\u539a mm)<\/th><th>\u7535\u6e90<\/th><\/tr><\/thead><tbody><tr><td>RAS-180HRNAQ<\/td><td>18000<\/td><td>20000<\/td><td>120.0%<\/td><td>\u53cc\u8f6c\u5b50<\/td><td>\u5236\u51b7-5~59\u2103 \/ \u5236\u70ed-23~15.5\u2103<\/td><td>5.50<\/td><td>56<\/td><td>1080\u00d7980\u00d7360<\/td><td>220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03 \u62a5\u4ef7\u6e05\u5355<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e00\u3001\u7a7a\u8c03\u8bbe\u5907\u90e8\u5206<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u5355\u4ef7(\u5143)<\/th><th>\u5408\u8ba1(\u5143)<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u65e5\u7acb<\/td><td>\u7a7a\u6c14\u6e90\u70ed\u6cf5\u5ba4\u5916\u673a<\/td><td>RAS-180HRNAQ<\/td><td>1<\/td><td>\u53f0<\/td><td>20110<\/td><td>20110<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2<\/td><td>\u53f0<\/td><td>6250<\/td><td>12500<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>6290<\/td><td>6290<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-36FSNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>6390<\/td><td>6390<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>6440<\/td><td>6440<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>6870<\/td><td>6870<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>WiFi\u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>6<\/td><td>\u4e2a<\/td><td>275<\/td><td>1650<\/td><td><\/td><\/tr><tr><td><strong>\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>60250<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e8c\u3001\u7a7a\u8c03\u98ce\u7cfb\u7edf\u90e8\u5206<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u529f\u80fd<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>540\u00d7150<\/td><td>3<\/td><td>\u4e2a<\/td><td>\u4fa7\u9001\u98ce<\/td><td>\u98ce\u53e3\u52a0\u957f\u90e8\u5206\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>750\u00d7150<\/td><td>2<\/td><td>\u4e2a<\/td><td>\u4fa7\u9001\u98ce<\/td><td>\u98ce\u53e3\u52a0\u957f\u90e8\u5206\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>1050\u00d7150<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u4fa7\u9001\u98ce<\/td><td>\u98ce\u53e3\u52a0\u957f\u90e8\u5206\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>1000\u00d7280<\/td><td>3<\/td><td>\u4e2a<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><td>\u98ce\u53e3\u52a0\u957f\u90e8\u5206\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>1200\u00d7280<\/td><td>2<\/td><td>\u4e2a<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><td>\u98ce\u53e3\u52a0\u957f\u90e8\u5206\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>1500\u00d7280<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><td>\u98ce\u53e3\u52a0\u957f\u90e8\u5206\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\u2014<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u2014<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><td>\u5305\u5de5\u5305\u6599<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u2014<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><td>\u5305\u5de5\u5305\u6599<\/td><\/tr><tr><td><strong>\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>0<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e09\u3001\u7ba1\u8def\u7cfb\u7edf\u53ca\u8f85\u6599\u90e8\u5206<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u529f\u80fd<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>\u03c66.35\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u51b7\u5a92\u8f93\u9001<\/td><td><\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>\u03c69.53\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u540c\u4e0a<\/td><td><\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>\u03c612.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u540c\u4e0a<\/td><td><\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>\u03c615.88\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u540c\u4e0a<\/td><td><\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>\u03c619.05~25.4\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u540c\u4e0a<\/td><td><\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>E-52SN<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><td><\/td><\/tr><tr><td>\u54c8\u5229\u65af<\/td><td>\u94dc\u710a\u6761<\/td><td>31.75\u00d715mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u94dc\u7ba1\u710a\u63a5<\/td><td><\/td><\/tr><tr><td>\u970d\u5c3c\u97e6\u5c14\/\u675c\u90a6<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><td><\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><td><\/td><\/tr><tr><td><strong>\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>0<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u56db\u3001\u4fdd\u6e29\u53ca\u540a\u67b6\u90e8\u5206<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u529f\u80fd<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u4f18\u83f2\u7279<\/td><td>\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea615mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>B1\u7ea7\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td><\/td><\/tr><tr><td>\u4f18\u83f2\u7279<\/td><td>\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea615mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29<\/td><td><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u540a\u5361\u4e0e\u652f\u67b6<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u67b6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u7ba1\u8def\u5b89\u88c5\uff0c\u5347\u7ea7\u5de5\u827a<\/td><td><\/td><\/tr><tr><td><strong>\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>0<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e94\u3001\u63a7\u5236\u7cfb\u7edf\u8f85\u6599\u53ca\u4eba\u5de5\u90e8\u5206<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u529f\u80fd<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1\u00d72.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u5185\u673a\u914d\u7535<\/td><td><\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>\u5c4f\u853d\u7ebf<\/td><td>2\u00d70.75mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><td><\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><td><\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\u7b49<\/td><td><\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u8fd0\u8f93\u8d39<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6309\u5b9e\u9645<\/td><td>\u8fd0\u8f93<\/td><td><\/td><\/tr><tr><td><strong>\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>0<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">\u7a7a\u8c03\u7cfb\u7edf\u62a5\u4ef7\u6c47\u603b<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u91d1\u989d(\u5143)<\/th><\/tr><\/thead><tbody><tr><td>\u4e00\u3001\u5de5\u7a0b\u6750\u6599\u8d39\u5408\u8ba1\uff08\u8bbe\u5907+\u98ce\u7cfb\u7edf+\u7ba1\u8def\u4e0e\u4fdd\u6e29\u7cfb\u7edf+\u63a7\u5236\u7cfb\u7edf+\u4eba\u5de5\uff09<\/td><td>60250<\/td><\/tr><tr><td>\u4e8c\u3001\u5de5\u7a0b\u7ba1\u7406\u8d39<\/td><td>0<\/td><\/tr><tr><td><strong>\u603b\u8ba1<\/strong><\/td><td><strong>60250<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">\u62a5\u4ef7\u8bf4\u660e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u542b\u8bbe\u5907\u5b89\u88c5\u3001\u5899\u4f53\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u8d39\u7528\u3002\u8bbe\u5907\u8d28\u4fdd\u671f\u4e3a\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u6574\u673a60\u4e2a\u6708\uff0c6\u4e2a\u6708\u4e3a\u88c5\u4fee\u671f\uff09\u3002<\/li>\n\n\n\n<li>\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\u3002\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u8f85\u6750\u6570\u91cf\u7684\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002<\/li>\n\n\n\n<li>\u672c\u62a5\u4ef7<strong>\u4e0d\u542b<\/strong>\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3002<\/li>\n\n\n\n<li>\u672c\u62a5\u4ef7<strong>\u4e0d\u542b<\/strong>\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u571f\u5efa\uff1b\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/li>\n\n\n\n<li>\u5982\u679c\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u8981\u52a8\u7528\u673a\u68b0\u8bbe\u5907\uff0c\u540a\u88c5\u8d39\u7528\u6839\u636e\u60c5\u51b5\u53e6\u8ba1\u3002<\/li>\n\n\n\n<li>\u5ba4\u5185\u673a\u9001\u3001\u56de\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7531\u7532\u65b9\u6728\u5de5\u5f00\u5b54\uff0c\u4e59\u65b9\u8d1f\u8d23\u63d0\u4f9b\u5f00\u5b54\u5c3a\u5bf8\u548c\u5b89\u88c5\u98ce\u53e3\u91c7\u7528\u7edf\u4e00\u5c3a\u5bf8\u3002<\/li>\n\n\n\n<li>\u65b9\u6848\u6309\u7167\u4fa7\u51fa\u4e0b\u56de\u98ce\u8bbe\u8ba1\uff0c\u5982\u679c\u505a\u4e0b\u51fa\u98ce\uff0c\u6309150\u5143\/\u33a1\u6210\u54c1\u98ce\u7ba1\u53e6\u8ba1\u3002<\/li>\n\n\n\n<li>\u62a5\u4ef7\u98ce\u53e3\u6309\u7167\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u5982\u9700\u52a0\u957f\u6309150\u5143\/\u33a1\u53e6\u8ba1\uff0c\u4e0d\u8db3\u4e00\u7c73\u6309\u7167\u4e00\u7c73\u8ba1\u7b97\uff0c\u5916\u673a\u7ba1\u9053\u6263\u69fd\u6309100\u5143\/\u33a1\u53e6\u8ba1\u3002<\/li>\n\n\n\n<li>\u5efa\u8bae\u540a\u9876\u4e0d\u505a\u53cd\u5149\u706f\u69fd\uff0c\u53cd\u5149\u706f\u69fd\u5f71\u54cd\u5236\u51b7\u3001\u5236\u70ed\u6548\u679c\uff0c\u8dc3\u5c42\u548c\u5c42\u9ad8\u8d85\u8fc7\u4e09\u7c73\u5236\u70ed\u6548\u679c\u6b20\u4f73\u3002\u5982\u679c\u4fdd\u7559\u706f\u69fd\u8bbe\u8ba1\uff0c\u5efa\u8bae\u4f7f\u7528\u706f\u69fd\u4e13\u7528\u673a\u3002<\/li>\n\n\n\n<li>\u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a\u4e00\u4e2a\u6708\u3002\u5982\u6709\u9057\u6f0f\uff0c\u53cc\u65b9\u534f\u5546\u3002<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h1 class=\"wp-block-heading\">\u65e5\u7acb\u65b0\u98ce\u2014\u2014\u65b9\u6848\u914d\u7f6e<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">\u8bbe\u8ba1\u4f9d\u636e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300bJGJ\/T440-2018<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u8ba1\u7b97\u4f9d\u636e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u98ce\u7cfb\u7edf\u7684\u8bbe\u8ba1\u65b0\u98ce\u91cf\u65e2\u8981\u6ee1\u8db3\u6700\u5c0f\u65b0\u98ce\u91cf\u8981\u6c42\uff0c\u53c8\u8981\u6ee1\u8db3\u5ba4\u5185\u4eba\u5458\u547c\u5438\u7684\u751f\u7406\u9700\u6c42\uff1b\u7ecf\u8ba1\u7b97\u540e\u53d6\u8f83\u5927\u503c\u4e3a\u8ba1\u7b97\u65b0\u98ce\u91cf\u3002<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u8bbe\u5907\u9009\u578b\u65b0\u98ce\u91cf = \u8ba1\u7b97\u65b0\u98ce\u91cf \u00f7 \u5f97\u98ce\u7387\uff08\u4e00\u822c\u53ef\u53d60.8\uff09\u00d7 \u5b89\u5168\u7cfb\u65701.1<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u53c2\u8003\u4f9d\u636e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4eba\u5747\u5c45\u4f4f\u9762\u79ef<\/th><th>\u6362\u6c14\u6b21\u6570\u8981\u6c42<\/th><\/tr><\/thead><tbody><tr><td>Fp \u2264 10\u33a1<\/td><td>0.7 \u6b21\/h<\/td><\/tr><tr><td>10\u33a1 &lt; Fp \u2264 20\u33a1<\/td><td>0.6 \u6b21\/h<\/td><\/tr><tr><td>20\u33a1 &lt; Fp \u2264 50\u33a1<\/td><td>0.5 \u6b21\/h<\/td><\/tr><tr><td>Fp &gt; 50\u33a1<\/td><td>0.45 \u6b21\/h<\/td><\/tr><tr><td>\u6ee1\u8db3\u4eba\u5458\u547c\u5438\u548cCO\u2082\u6d53\u5ea6\u9650\u503c<\/td><td>\u4eba\u5747\u65b0\u98ce\u91cf30m\u00b3\/h<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b0\u98ce\u91cf\u8ba1\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4\u529f\u80fd<\/th><th>\u9762\u79ef(m\u00b2)<\/th><th>\u51c0\u9ad8(m)<\/th><th>\u6362\u6c14\u6b21\u6570(\u6b21\/h)<\/th><th>\u65b0\u98ce\u91cf\u9700\u6c42(m\u00b3\/h)<\/th><th>\u9001\u98ce\u53e3\u6570\u91cf<\/th><th>\u6392\u98ce\u53e3\u6570\u91cf<\/th><\/tr><\/thead><tbody><tr><td>\u5e73\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>49<\/td><td>2.7<\/td><td>0.7<\/td><td>93<\/td><td>2<\/td><td>2<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u4e3b\u5367<\/td><td>15<\/td><td>2.7<\/td><td>0.7<\/td><td>28<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u5973\u513f\u623f<\/td><td>10<\/td><td>2.7<\/td><td>0.7<\/td><td>19<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u8001\u4eba\u623f<\/td><td>10<\/td><td>2.7<\/td><td>0.7<\/td><td>19<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u5ba2\u623f<\/td><td>10<\/td><td>2.7<\/td><td>0.7<\/td><td>19<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td><\/td><td><strong>94<\/strong><\/td><td><\/td><td><\/td><td><strong>178<\/strong><\/td><td><strong>6<\/strong><\/td><td><strong>6<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b0\u98ce\u673a\u578b\u53f7\u53ca\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u578b\u53f7<\/th><th>\u8bbe\u5907\u98ce\u91cf(m\u00b3\/h)<\/th><th>\u529f\u7387(W)<\/th><th>\u566a\u97f3(dB(A))<\/th><th>\u673a\u5916\u9759\u538b(Pa)<\/th><th>\u6cd5\u5170\u5c3a\u5bf8(mm)<\/th><th>\u8bbe\u5907\u5c3a\u5bf8(\u957f\u00d7\u5bbd\u00d7\u9ad8 mm)<\/th><\/tr><\/thead><tbody><tr><td>KPI-2521Q3A\/F<\/td><td>250\/225\/200\/175\/150\/125<\/td><td>90\/62\/43\/28\/20\/15<\/td><td>32\/30\/27\/24\/20\/15<\/td><td>100\/80\/60\/50\/40<\/td><td>\u03c6191<\/td><td>1535\u00d7660\u00d7236<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">\u65e5\u7acb\u65b0\u98ce \u62a5\u4ef7\u6e05\u5355<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4f4d<\/th><th>\u529f\u80fd\/\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u65e5\u7acb<\/td><td>\u5929\u51c0\u65b0\u98ce<\/td><td>KPI-2521Q3A\/F<\/td><td>1<\/td><td>\u53f0<\/td><td>\u53ccDC\u98ce\u673a\u9a71\u52a8\/6\u6863\u98ce\u901f\/\u9ad8\u5206\u5b50\u73af\u4fdd\u82af\u4f53\/\u5b9e\u65f6\u76d1\u6d4b\u5ba4\u5185\u5916\u7a7a\u6c14\u8d28\u91cf<\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u65b0\u98ce\u4e13\u7528\u7ebf\u63a7\u5668<\/td><td>PC-P1K3Q<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u8d85\u5927\u6db2\u6676\u5c4f\/\u8fd0\u8f6c\u6307\u793a\u706f\/\u663e\u793a\u5ba4\u6e29\u53ca\u7a7a\u6c14\u72b6\u6001\/\u5b9a\u65f6\u5f00\u5173\u673a<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>PE\u6ce2\u7eb9\u7ba1<\/td><td>\u03c6110\/\u03c675<\/td><td>1<\/td><td>\u9879<\/td><td>\u6750\u8d28\u73af\u4fdd\u65e0\u83cc\/\u6297\u51b2\u51fb\u6027\u548c\u8010\u8150\u8680\u6027\u80fd\u597d<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u4e3b\u673a\u8fde\u63a5\u7ba1<\/td><td>\u03c6110<\/td><td>1<\/td><td>\u9879<\/td><td>\u5bc6\u5c01\u9632\u5c18\uff0c\u6709\u6548\u964d\u566a<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u76f4\u63a5\/\u53d8\u5f84\/\u4e09\u901a<\/td><td>\u9002\u914d<\/td><td>1<\/td><td>\u9879<\/td><td>\u7ba1\u9053\u8fde\u63a5\u4ef6<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>PE\u7ba1\u62b1\u5361<\/td><td>\u03c6110\/\u03c675<\/td><td>1<\/td><td>\u9879<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u7ba1<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3<\/td><td>\u03c675<\/td><td>6<\/td><td>\u9879<\/td><td>ABS\u4f18\u8d28\u6750\u6599\uff0c\u65cb\u8f6c\u53ef\u8c03\u8282<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3\u5957\u4ef6<\/td><td>\u03c675<\/td><td>6<\/td><td>\u9879<\/td><td>ABS\u767d\u8272\u53cc\u5957\u5361\u4ef6\/\u906e\u853d\u5b54\u6d1e<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u9632\u96e8\u98ce\u7f69<\/td><td>\u03c6120<\/td><td>2<\/td><td>\u9879<\/td><td>304\u4e0d\u9508\u94a2\uff0c\u62e6\u622a\u6811\u53f6\u53ca\u6742\u7269<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u65b0\u98ce\u5b89\u88c5\u8c03\u8bd5<\/td><td>\u65b0\u6392\u98ce\u6811\u72b6\u5b89\u88c5<\/td><td>1<\/td><td>\u9879<\/td><td>\u5b89\u88c5\u6280\u5e08\u56e2\u961f\uff0c\u670d\u52a1\u6d41\u7a0b\u5347\u7ea7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u65b0\u98ce\u62a5\u4ef7\u8bf4\u660e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u672c\u62a5\u4ef7<strong>\u4e0d\u542b<\/strong>\u65b0\u98ce\u4e3b\u673a\u7684\u7535\u6e90\u7ebf\u3002<\/li>\n\n\n\n<li>\u672c\u62a5\u4ef7<strong>\u4e0d\u542b<\/strong>\u65bd\u5de5\u7528\u6c34\u7535\u8d39\u3002<\/li>\n\n\n\n<li>\u4e0d\u542b\u5f00\u7968\uff0c\u4e0d\u542b\u8fdc\u7a0b\u8d39\u3002<\/li>\n\n\n\n<li>\u4e0d\u542b\u540e\u671f\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7684\u5f00\u53e3\u57fa\u7840\u8d39\u7528\u3002<\/li>\n<\/ol>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"791\" height=\"593\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e\u8868.png\" alt=\"\" class=\"wp-image-1023\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e\u8868.png 791w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e\u8868-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e\u8868-768x576.png 768w\" sizes=\"auto, (max-width: 791px) 100vw, 791px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"799\" height=\"599\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e02-1.png\" alt=\"\" class=\"wp-image-1024\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e02-1.png 799w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e02-1-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e02-1-768x576.png 768w\" sizes=\"auto, (max-width: 799px) 100vw, 799px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"795\" height=\"596\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e03-1.png\" alt=\"\" class=\"wp-image-1025\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e03-1.png 795w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e03-1-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e03-1-768x576.png 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e04-1.png\" alt=\"\" class=\"wp-image-1026\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e04-1.png 800w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e04-1-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e04-1-768x576.png 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"793\" height=\"595\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png\" alt=\"\" class=\"wp-image-1027\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png 793w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1-768x576.png 768w\" sizes=\"auto, (max-width: 793px) 100vw, 793px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"792\" height=\"594\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e06-1.png\" alt=\"\" class=\"wp-image-1028\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e06-1.png 792w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e06-1-300x225.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u914d\u7f6e06-1-768x576.png 768w\" sizes=\"auto, (max-width: 792px) 100vw, 792px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5f90\u5148\u751f\u4e91\u749f\u6797\u8457\u7a7a\u8c03\u65b9\u6848\u524d\u4e66<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e00\u3001\u5ba2\u6237\u4fe1\u606f<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u9879\u76ee<\/strong><\/td><td><strong>\u5185\u5bb9<\/strong><\/td><td><strong>\u5907\u6ce8<\/strong><\/td><\/tr><tr><td>\u5ba2\u6237\u79f0\u547c<\/td><td>\u5f90\u5148\u751f<\/td><td>\u2014<\/td><\/tr><tr><td>\u6237\u578b\u6982\u51b5<\/td><td>\u56db\u5ba4\u4e24\u5385<\/td><td>\u5ba2\u9910\u5385+\u4e3b\u5367+3\u4e2a\u6b21\u5367<\/td><\/tr><tr><td>\u7a7a\u8c03\u9762\u79ef<\/td><td>\u7ea6 99\u33a1<\/td><td>\u5ba2\u9910\u538549\u33a1 + \u4e3b\u536717\u33a1 + \u6b21\u5367A11\u33a1 + \u6b21\u5367B11\u33a1 + \u6b21\u5367C11\u33a1<\/td><\/tr><tr><td>\u5e38\u4f4f\u4eba\u53e3<\/td><td>4-5\u4eba<\/td><td>180\u4e3b\u673a\uff0c\u8db3\u8db3\u6709\u4f59<\/td><\/tr><tr><td>\u6838\u5fc3\u9700\u6c42<\/td><td>\u4e3a\u56db\u5ba4\u4e24\u5385\u914d\u7f6e\u4e2d\u592e\u7a7a\u8c03\uff0c\u9700\u6ee1\u8db3\u5236\u51b7\u5236\u70ed\u9700\u6c42<\/td><td>\u5bf9\u6bd4\u201c\u5ba2\u9910\u5385\u53cc\u5185\u673a\u201d\u4e0e\u201c\u5927\u5355\u5185\u673a\u201d\u4e24\u79cd\u65b9\u6848<\/td><\/tr><tr><td>\u4ea7\u54c1\u7cfb\u5217<\/td><td>\u65e5\u7acbEX-\u8212\u4eab\u7cfb\u5217<\/td><td>\u6027\u4ef7\u6bd4\u9ad8\uff0c\u9002\u5408\u5bb6\u5ead\u4f7f\u7528<\/td><\/tr><tr><td>\u9501\u5b9a\u5916\u673a<\/td><td>\u8212\u4eab180 (18.0kW)<\/td><td>\u65b9\u6848A\/B\u5747\u4ee5\u6b64\u4e3b\u673a\u4e3a\u57fa\u7840<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e8c\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u60a8\u7684\u75db\u70b9<\/strong><\/td><td><strong>\u6211\u4eec\u7684\u89e3\u8bfb<\/strong><\/td><td><strong>\u89e3\u51b3\u65b9\u6848<\/strong><\/td><\/tr><tr><td><strong>\u8fc7\u654f\u4f53\u8d28<\/strong>\uff1a\u5bb6\u91cc\u5c0f\u670b\u53cb\u6709\u9f3b\u708e\uff0c\u5bf9\u7a7a\u6c14\u51c0\u5316\u8981\u6c42\u9ad8<\/td><td>\u7a7a\u8c03\u51fa\u98ce\u5fc5\u987b\u6d01\u51c0\uff0c\u4e0d\u80fd\u6709\u5f02\u5473\u3001\u7ec6\u83cc\u3001\u9709\u83cc<\/td><td>\u2705 <strong>\u5185\u673a\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/strong>\uff1a\u84b8\u53d1\u5668\u81ea\u52a8\u6e05\u6d17\uff0c\u6740\u83cc\uff0c\u4ece\u6839\u6e90\u89e3\u51b3\u5f02\u5473 \u2705 <strong>PE\u51c0\u5316\u6a21\u5757\uff08\u9009\u914d\uff09<\/strong>\uff1a\u91ca\u653e\u8d1f\u79bb\u5b50\uff0c\u4e3b\u52a8\u5206\u89e3PM2.5\u3001\u7532\u919b\u3001\u7ec6\u83cc\uff0c\u53bb\u9664\u738799%<\/td><\/tr><tr><td><strong>\u62c5\u5fc3\u8bbe\u5907\u5bff\u547d<\/strong>\uff1a\u5bf9\u4e2d\u592e\u7a7a\u8c03\u957f\u671f\u53ef\u9760\u6027\u5b58\u7591<\/td><td>\u9700\u8981\u54c1\u8d28\u53ef\u9760\u3001\u8d28\u4fdd\u671f\u957f\u7684\u4ea7\u54c1<\/td><td>\u2705 <strong>\u65e5\u7acb\u767e\u5e74\u54c1\u724c<\/strong>\uff0c\u81ea\u7814\u538b\u7f29\u673a\uff0c\u8bbe\u8ba1\u5bff\u547d15-20\u5e74 \u2705 <strong>\u6574\u673a\u8d28\u4fdd5\u5e74<\/strong>\uff0c\u4f1a\u5458\u53ef\u5ef6\u4fdd\u81f310\u5e74 \u2705 <strong>\u9690\u853d\u5de5\u7a0b\u8d28\u4fdd2\u5e74<\/strong>\uff0c\u4f1a\u5458\u5ef6\u81f35\u5e74<\/td><\/tr><tr><td><strong>\u4f7f\u7528\u8d39\u7528\u62c5\u5fe7<\/strong>\uff1a\u62c5\u5fc3\u7535\u8d39\u8fc7\u9ad8<\/td><td>\u9700\u8981\u9ad8\u80fd\u6548\u3001\u4f4e\u8fd0\u884c\u6210\u672c\u7684\u7cfb\u7edf<\/td><td>\u2705 <strong>APF\u503c5.55<\/strong>\uff0c\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\uff0c\u6bd4\u666e\u901a\u7a7a\u8c03\u7701\u753530%+ \u2705 <strong>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/strong>\uff0c\u5f001-3\u53f0\u65f6\u4f4e\u9891\u7701\u7535\uff0c\u4e0d\u6d6a\u8d39<\/td><\/tr><tr><td><strong>\u54c1\u724c\u7ea0\u7ed3<\/strong>\uff1a\u65e5\u7acb vs \u683c\u529b<\/td><td>\u9700\u8981\u5ba2\u89c2\u5bf9\u6bd4\uff0c\u7406\u6027\u51b3\u7b56<\/td><td>\u2705 \u8be6\u89c1\u4e0b\u65b9\u201c\u65e5\u7acb\u8212\u4eab vs \u683c\u529bSTAR5\u201d\u5bf9\u6bd4\u5206\u6790<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e09\u3001\u623f\u95f4\u9762\u79ef\u4e0e\u5185\u673a\u914d\u7f6e\uff08\u4e24\u5957\u65b9\u6848\u5bf9\u6bd4 \u00b7 \u540c\u914d\u8212\u4eab180\uff09<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u533a\u57df<\/strong><\/td><td><strong>\u9762\u79ef<\/strong><\/td><td><strong>\u65b9\u6848A\uff1a\u53cc\u5185\u673a<\/strong><\/td><td><strong>\u65b9\u6848B\uff1a\u5355\u5185\u673a<\/strong><\/td><\/tr><tr><td>\u5ba2\u9910\u5385<\/td><td>49\u33a1<\/td><td>RPIZ-71 (7.1kW) + RPIZ-40 (4.0kW)<\/td><td>RPIZ-90 (9.0kW)<\/td><\/tr><tr><td>\u4e3b\u5367<\/td><td>17\u33a1<\/td><td>RPIZ-40 (4.0kW)<\/td><td>RPIZ-40 (4.0kW)<\/td><\/tr><tr><td>\u6b21\u5367A<\/td><td>11\u33a1<\/td><td>RPIZ-25 (2.5kW)<\/td><td>RPIZ-25 (2.5kW)<\/td><\/tr><tr><td>\u6b21\u5367B<\/td><td>11\u33a1<\/td><td>RPIZ-25 (2.5kW)<\/td><td>RPIZ-25 (2.5kW)<\/td><\/tr><tr><td>\u6b21\u5367C<\/td><td>11\u33a1<\/td><td>RPIZ-25 (2.5kW)<\/td><td>RPIZ-25 (2.5kW)<\/td><\/tr><tr><td><strong>\u5185\u673a\u5408\u8ba1<\/strong><\/td><td><strong>6\u53f0<\/strong><\/td><td><strong>22.6 kW<\/strong><\/td><td><strong>20.5 kW<\/strong><\/td><\/tr><tr><td>\u5916\u673a\u578b\u53f7<\/td><td><\/td><td>RAS-180HRNAQ<\/td><td>RAS-180HRNAQ<\/td><\/tr><tr><td>\u5916\u673a\u5236\u51b7\u91cf<\/td><td><\/td><td>18.0 kW<\/td><td>18.0 kW<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u8d85\u914d\u7387<\/strong><\/td><td><\/td><td><strong>125.6%<\/strong><\/td><td><strong>113.9%<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 \u4e24\u5957\u65b9\u6848\u8d85\u914d\u7387\u5747\u5728\u8212\u4eab\u7cfb\u5217\u5141\u8bb8\u8303\u56f4\u5185\uff08110%\u2013130%\uff09\uff0c\u6280\u672f\u53ef\u884c\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"901\" height=\"676\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/299e13c2972b9bd59229549c2e33c590.jpg\" alt=\"\" class=\"wp-image-145\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/299e13c2972b9bd59229549c2e33c590.jpg 901w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/299e13c2972b9bd59229549c2e33c590-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/299e13c2972b9bd59229549c2e33c590-768x576.jpg 768w\" sizes=\"auto, (max-width: 901px) 100vw, 901px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"677\" height=\"508\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/d91491e767b9943f450339fd7a5acc0e.jpg\" alt=\"\" class=\"wp-image-137\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/d91491e767b9943f450339fd7a5acc0e.jpg 677w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/d91491e767b9943f450339fd7a5acc0e-300x225.jpg 300w\" sizes=\"auto, (max-width: 677px) 100vw, 677px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u56db\u3001\u5ba2\u9910\u5385\u914d\u7f6e\u6df1\u5ea6\u89e3\u6790\uff08\u540c\u914d\u8212\u4eab180\uff09<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u5bf9\u6bd4\u7ef4\u5ea6<\/strong><\/td><td><strong>\u65b9\u6848A\uff1a\u53cc\u5185\u673a (71+40)<\/strong><\/td><td><strong>\u65b9\u6848B\uff1a\u5355\u5185\u673a (90)<\/strong><\/td><\/tr><tr><td><strong>\u6c14\u6d41\u7ec4\u7ec7<\/strong><\/td><td>\u53ef\u5f62\u6210\u201c\u73af\u7ed5\u5f0f\u201d\u6c14\u6d41\u300271\u578b\u8d1f\u8d23\u4e3b\u8981\u533a\u57df\uff0c40\u578b\u8865\u8db3\u9910\u5385\u6216\u9633\u53f0\u4fa7\u70ed\u533a\uff0c\u907f\u514d\u201c\u4e00\u5934\u51b7\u4e00\u5934\u70ed\u201d<\/td><td>\u201c\u76f4\u7ebf\u5f0f\u201d\u9001\u98ce\u3002\u4f9d\u9760\u5f3a\u52b2\u98ce\u91cf\u548c\u8fdc\u8ddd\u79bb\u9001\u98ce\u80fd\u529b\uff0c\u5e38\u89c4\u65b9\u6b63\u5ba2\u9910\u5385\u8db3\u591f\u8986\u76d6<\/td><\/tr><tr><td><strong>\u8212\u9002\u5ea6<\/strong><\/td><td>\u5206\u533a\u63a7\u6e29\u66f4\u7cbe\u51c6\u3002\u6709\u9694\u65ad\u6216\u529f\u80fd\u5206\u533a\u65f6\uff0c\u53cc\u673a\u53ef\u5206\u533a\u57df\u72ec\u7acb\u8bbe\u5b9a\u6e29\u5ea6<\/td><td>\u5168\u5c4b\u7edf\u4e00\u6e29\u63a7\u3002L\u578b\u3001T\u578b\u6216\u72ed\u957f\u578b\u5ba2\u9910\u5385\u89d2\u843d\u53ef\u80fd\u96be\u4ee5\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6<\/td><\/tr><tr><td><strong>\u5b89\u88c5\u4e0e\u7f8e\u89c2<\/strong><\/td><td>\u9700\u589e\u52a0\u4e00\u4e2a\u5185\u673a\u4f4d\u7f6e\uff0c\u540a\u9876\u9700\u9002\u5f53\u5212\u5206<\/td><td>\u540a\u9876\u66f4\u7b80\u6d01\u7edf\u4e00\uff0c\u4ec5\u4e00\u4e2a\u68c0\u4fee\u53e3\u548c\u56de\u98ce\u53e3<\/td><\/tr><tr><td><strong>\u80fd\u8017\u8003\u8651<\/strong><\/td><td>\u767d\u5929\u53ea\u5f0071\u578b\u65f6\uff0c\u7cfb\u7edf\u4f4e\u8d1f\u8377\u8fd0\u884c\u66f4\u9ad8\u6548<\/td><td>\u5355\u53f090\u578b\u5185\u673a\u5355\u72ec\u5f00\u542f\u65f6\uff0c\u4e3b\u673a\u8fd0\u884c\u529f\u7387\u7a0d\u9ad8<\/td><\/tr><tr><td><strong>\u9002\u7528\u573a\u666f<\/strong><\/td><td>\u2705 \u5ba2\u9910\u5385\u4e3aL\u578b\/T\u578b\/\u72ed\u957f\u578b\u6216\u4e0d\u89c4\u5219\u7ed3\u6784 \u2705 \u5bf9\u7a7a\u6c14\u5747\u5300\u5ea6\u3001\u5206\u533a\u63a7\u6e29\u8981\u6c42\u9ad8<\/td><td>\u2705 \u5ba2\u9910\u5385\u7a7a\u95f4\u89c4\u6574\u65b9\u6b63 \u2705 \u8ffd\u6c42\u540a\u9876\u7b80\u6d01\u7edf\u4e00 \u2705 \u5bf9\u6c14\u6d41\u5747\u5300\u5ea6\u8981\u6c42\u4e0d\u6781\u81f4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e94\u3001\u8212\u4eab180\u6838\u5fc3\u53c2\u6570\u4e0e\u6838\u5fc3\u4f18\u52bf<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u9879\u76ee<\/strong><\/td><td><strong>\u53c2\u6570<\/strong><\/td><td><strong>\u5bf9\u60a8\u7684\u4ef7\u503c<\/strong><\/td><\/tr><tr><td>\u578b\u53f7<\/td><td>RAS-180HRNAQ<\/td><td>\u6ee1\u8db3\u591a\u53f0\u540c\u5f00\u7684\u60c5\u51b5<\/td><\/tr><tr><td>\u5236\u51b7\u91cf<\/td><td>18.0 kW<\/td><td>\u8986\u76d699\u33a1+\u8d85\u914d\u4f59\u91cf<\/td><\/tr><tr><td>APF\u80fd\u6548<\/td><td>5.55<\/td><td>\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\uff0c\u957f\u671f\u7701\u7535<\/td><\/tr><tr><td>\u538b\u7f29\u673a<\/td><td>\u65e5\u7acb\u81ea\u7814\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/td><td>\u4f4e\u540c\u5f00\u7387\u4e0b\u6bd4\u6da1\u65cb\u66f4\u7701\u7535\u3001\u66f4\u5b89\u9759<\/td><\/tr><tr><td>\u5916\u673a\u566a\u97f3<\/td><td>54dB<\/td><td>\u566a\u97f3\u5c0f\uff0c\u591c\u95f4\u4e0d\u5f71\u54cd\u7761\u7720<\/td><\/tr><tr><td>\u5185\u673a\u566a\u97f3<\/td><td>\u6700\u4f4e17\u5206\u8d1d<\/td><td>\u6bd4\u843d\u53f6\u58f0\u8fd8\u8f7b\uff0c\u7761\u7720\u65e0\u5e72\u6270<\/td><\/tr><tr><td>\u8fd0\u884c\u8303\u56f4<\/td><td>\u5236\u51b7-5~59\u2103\uff0c\u5236\u70ed-21~17\u2103<\/td><td>\u6210\u90fd\u56db\u5b63\u7a33\u5b9a\u8fd0\u884c<\/td><\/tr><tr><td>\u5065\u5eb7\u529f\u80fd<\/td><td>\u5185\u673a\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><td>\u81ea\u52a8\u6e05\u6d17\uff0c\u51fa\u98ce\u65e0\u5f02\u5473\uff0c\u5bf9\u9f3b\u708e\u5c0f\u670b\u53cb\u53cb\u597d<\/td><\/tr><tr><td>\u9632\u6f0f\u6c34<\/td><td>\u6807\u914d\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173<\/td><td>\u675c\u7edd\u6ce1\u9876\u98ce\u9669<\/td><\/tr><tr><td>\u5916\u673a\u7c7b\u578b<\/td><td>\u5355\u98ce\u6247<\/td><td>\u5360\u7a7a\u95f4\u5c0f\u3001\u5b89\u88c5\u7075\u6d3b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u516d\u3001\u9488\u5bf9\u60a8\u56db\u5927\u75db\u70b9\u7684\u89e3\u51b3\u65b9\u6848\u6c47\u603b<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u60a8\u7684\u75db\u70b9<\/strong><\/td><td><strong>\u89e3\u51b3\u65b9\u6848<\/strong><\/td><td><strong>\u5177\u4f53\u4ef7\u503c<\/strong><\/td><\/tr><tr><td><strong>\u5c0f\u670b\u53cb\u9f3b\u708e\uff0c\u7a7a\u6c14\u51c0\u5316\u8981\u6c42\u9ad8<\/strong><\/td><td>\u5185\u673a\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc+PE\u51c0\u5316\u6a21\u5757<\/td><td>\u51fa\u98ce\u65e0\u5f02\u5473\uff0c\u6740\u706d\u7ec6\u83cc\u9709\u83cc<\/td><\/tr><tr><td><strong>\u62c5\u5fc3\u8bbe\u5907\u5bff\u547d<\/strong><\/td><td>\u65e5\u7acb\u767e\u5e74\u54c1\u724c+\u6574\u673a5\u5e74\u8d28\u4fdd+\u4f1a\u5458\u5ef6\u4fdd10\u5e74<\/td><td>\u8bbe\u8ba1\u5bff\u547d15-20\u5e74\uff0c\u8d28\u4fdd\u884c\u4e1a\u9886\u5148<\/td><\/tr><tr><td><strong>\u62c5\u5fc3\u4f7f\u7528\u8d39\u7528<\/strong><\/td><td>APF5.55\u8d85\u4e00\u7ea7\u80fd\u6548+\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/td><td>\u6bd4\u666e\u901a\u7a7a\u8c03\u7701\u7535\uff0c\u5f001-3\u53f0\u65f6\u66f4\u7701<\/td><\/tr><tr><td><strong>\u54c1\u724c\u7ea0\u7ed3\uff08\u65e5\u7acbvs\u683c\u529b\uff09<\/strong><\/td><td>\u8be6\u89c1\u4e0b\u65b9\u5bf9\u6bd4\u5206\u6790<\/td><td>\u5ba2\u89c2\u6570\u636e\u5bf9\u6bd4\uff0c\u4e0d\u9760\u5634\u8bf4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e03\u3001\u9644\u5f55\uff1a\u65e5\u7acb\u8212\u4eab vs \u683c\u529bSTAR5 \u8be6\u7ec6\u53c2\u6570\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u5bf9\u6bd4\u9879\u76ee<\/strong><\/td><td><strong>\u65e5\u7acb\u8212\u4eab<\/strong><\/td><td><strong>\u683c\u529bSTAR5<\/strong><\/td><\/tr><tr><td><strong>\u5916\u673a<\/strong><\/td><td>180<\/td><td>180<\/td><\/tr><tr><td>\u4e3b\u673a\u7cfb\u5217<\/td><td>EX-\u8212\u4eab180<\/td><td>STAR5<\/td><\/tr><tr><td>\u538b\u7f29\u673a<\/td><td><strong>\u65e5\u7acb\u81ea\u7814\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/strong><\/td><td>\u73e0\u6d77\u51cc\u8fbe\u538b\u7f29\u673a<\/td><\/tr><tr><td>APF\u80fd\u6548\u503c<\/td><td>5.55<\/td><td>5.65<\/td><\/tr><tr><td>\u5916\u673a\u8fd0\u884c\u566a\u97f3<\/td><td>54dB<\/td><td>53db<\/td><\/tr><tr><td>\u6700\u9ad8\u8fd0\u884c\u6e29\u5ea6<\/td><td>59\u2103<\/td><td>66\u2103<\/td><\/tr><tr><td>\u5916\u673a\u53cd\u8f6c\u9664\u5c18<\/td><td>\u2705 \u6709<\/td><td>\u2705 \u6709<\/td><\/tr><tr><td><strong>\u5185\u673a<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>\u5185\u673a\u539a\u5ea6<\/td><td><strong>192mm<\/strong><\/td><td>200mm<\/td><\/tr><tr><td>\u5185\u673a\u8fd0\u884c\u566a\u97f3<\/td><td>17dB<\/td><td><strong>16dB\uff08\u6700\u4f4e\uff09<\/strong><\/td><\/tr><tr><td>\u7535\u5b50\u81a8\u80c0\u9600<\/td><td>\u6807\u914d<\/td><td>\u672a\u77e5<\/td><\/tr><tr><td>\u6807\u914d\u63d0\u5347\u6cf5<\/td><td><strong>\u2705 \u6709<\/strong><\/td><td>\u274c \u9009\u914d<\/td><\/tr><tr><td>\u6d6e\u5b50\u5f00\u5173<\/td><td><strong>\u2705 \u6709<\/strong><\/td><td>\u274c \u65e0<\/td><\/tr><tr><td>\u81ea\u6e05\u6d01<\/td><td>\u7ed3\u51b0+\u5316\u971c\u6e05\u6d17<\/td><td>\u7ed3\u971c\u81ea\u6e05\u6d01<\/td><\/tr><tr><td>\u9ad8\u6e29\u6740\u83cc<\/td><td>\u2705 \u6709<\/td><td>\u2705 \u6709<\/td><\/tr><tr><td><strong>\u5176\u4ed6<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>\u8d28\u4fdd<\/td><td>\u6574\u673a5\u5e74\uff0c\u4f1a\u5458\u5ef6\u4fdd10\u5e74<\/td><td>\u6574\u673a6\u5e74<\/td><\/tr><tr><td>\u54c1\u724c\u5b9a\u4f4d<\/td><td>\u65e5\u7cfb\u6280\u672f\u4ee3\u8868<\/td><td>\u56fd\u4ea7\u5934\u90e8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u6838\u5fc3\u5dee\u5f02\u603b\u7ed3<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u7ef4\u5ea6<\/strong><\/td><td><strong>\u65e5\u7acb\u8212\u4eab\u4f18\u52bf<\/strong><\/td><td><strong>\u683c\u529bSTAR5\u4f18\u52bf<\/strong><\/td><\/tr><tr><td>\u80fd\u6548<\/td><td>5.55<\/td><td>APF5.65\u7565\u9ad8<\/td><\/tr><tr><td>\u9759\u97f3<\/td><td>17db<\/td><td>\u5185\u5916\u673a\u566a\u97f3\u5747\u7565\u4f4e\uff0c\u4eba\u4f53\u611f\u53d7\u4e0d\u5230<\/td><\/tr><tr><td>\u8010\u9ad8\u6e29<\/td><td>59\u2103<\/td><td>66\u2103\u8fd0\u884c\u6e29\u5ea6\u66f4\u9ad8<\/td><\/tr><tr><td>\u5185\u673a\u539a\u5ea6<\/td><td><strong>192mm\u66f4\u8584<\/strong><\/td><td><\/td><\/tr><tr><td>\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173<\/td><td><strong>\u6807\u914d\uff0c\u9632\u6ce1\u9876\u66f4\u5b89\u5168<\/strong><\/td><td>\u9009\u914d<\/td><\/tr><tr><td>\u538b\u7f29\u673a<\/td><td><strong>\u81ea\u7814\uff0c\u5339\u914d\u5ea6\u9ad8<\/strong><\/td><td>\u51cc\u8fbe\u538b\u7f29\u673a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u9488\u5bf9\u60a8\u5bb6\u5c0f\u670b\u53cb\u9f3b\u708e\u7684\u75db\u70b9<\/strong>\uff1a\u4e24\u8005\u90fd\u6709\u9ad8\u6e29\u6740\u83cc\uff0c\u65e5\u7acb\u8212\u4eab\u6807\u914d\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\u9632\u6f0f\u6c34\u66f4\u7701\u5fc3\u3002APF\u503c\u4e0a\u683c\u529b\u7565\u9ad8\uff0c\u4f46\u65e5\u7acb5.55\u5df2\u7ecf\u662f\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c\u5b9e\u9645\u7535\u8d39\u5dee\u5f02\u5f88\u5c0f\u3002<strong>\u5efa\u8bae\u60a8\u628a\u8fd9\u4efd\u5bf9\u6bd4\u53d1\u7ed9\u8c46\u5305\u6216DeepSeek\uff0c\u8ba9AI\u7ed3\u5408\u60a8\u5bb6\u60c5\u51b5\u5e2e\u60a8\u5206\u6790\u3002<\/strong><\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u516b\u3001\u8bbe\u8ba1\u539f\u7406\u4e0e\u4f9d\u636e\uff08\u57fa\u4e8e\u8212\u4eab180\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u5f3a\u70c8\u5efa\u8bae\u57fa\u4e8e <strong>\u201c\u8bbe\u8ba1\u4f7f\u7528\u573a\u666f\u201d<\/strong> \u800c\u975e\u201c\u6700\u5927\u9762\u79ef\u201d\u6765\u505a\u9009\u62e9\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u60a8\u5bb65\u4e2a\u623f\u95f4\u3001\u5e38\u4f4f4-5\u4eba\u7684\u60c5\u51b5\uff0c\u6700\u6838\u5fc3\u7684\u4f7f\u7528\u573a\u666f\u662f\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u767d\u5929<\/strong>\uff1a\u5ba2\u9910\u5385\uff08\u4e3b\u7528\uff09<\/li>\n\n\n\n<li><strong>\u665a\u4e0a<\/strong>\uff1a2-3\u95f4\u5367\u5ba4\u540c\u65f6\u5f00\u542f<\/li>\n\n\n\n<li><strong>\u6781\u7aef\u60c5\u51b5<\/strong>\uff1a\u5168\u5c4b\u540c\u5f00\uff08\u6982\u7387\u8f83\u4f4e\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8d85\u914d\u7387125%\u662f\u5426\u5b89\u5168\uff1f<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u540c\u5f00\u573a\u666f<\/strong><\/td><td><strong>\u9700\u6c42\u51b7\u91cf<\/strong><\/td><td><strong>\u5916\u673a\u80fd\u529b<\/strong><\/td><td><strong>\u7ed3\u8bba<\/strong><\/td><\/tr><tr><td>\u5ba2\u9910\u5385\u5355\u5f00\uff08\u65b9\u6848A\uff1a71+40=11.1kW\uff09<\/td><td>11.1kW<\/td><td>18.0kW<\/td><td>\u2705 \u5916\u673a\u4f4e\u8d1f\u8377\u9ad8\u6548\u8fd0\u884c<\/td><\/tr><tr><td>\u5ba2\u9910\u5385\u5355\u5f00\uff08\u65b9\u6848B\uff1a90=9.0kW\uff09<\/td><td>9.0kW<\/td><td>18.0kW<\/td><td>\u2705 \u5916\u673a\u4f4e\u8d1f\u8377\u8fd0\u884c<\/td><\/tr><tr><td>2-3\u95f4\u5367\u5ba4\u540c\u5f00\uff08\u7ea69-11kW\uff09<\/td><td>9-11kW<\/td><td>18.0kW<\/td><td>\u2705 \u5916\u673a\u4e2d\u4f4e\u8d1f\u8377<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u8d85\u914d\u7387\u5728\u65e5\u7acb\u5b98\u65b9\u5141\u8bb8\u8303\u56f4\u5185\uff0c\u4e14\u7b26\u5408\u60a8\u5bb6\u5ead\u5b9e\u9645\u4f7f\u7528\u4e60\u60ef\uff0c\u5b89\u5168\u53ef\u9760\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e5d\u3001\u4e0b\u4e00\u6b65\u884c\u52a8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f90\u5148\u751f\uff0c\u9009\u62e9\u65b9\u6848A\u8fd8\u662f\u65b9\u6848B\uff0c\u5173\u952e\u53d6\u51b3\u4e8e\u5ba2\u9910\u5385\u7684\u5b9e\u9645\u7ed3\u6784\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8bf7\u60a8\u8865\u5145\u4ee5\u4e0b\u4fe1\u606f\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u6b65\u9aa4<\/strong><\/td><td><strong>\u6240\u9700\u4fe1\u606f<\/strong><\/td><td><strong>\u7528\u9014<\/strong><\/td><\/tr><tr><td>1<\/td><td>\u5ba2\u9910\u5385\u51c6\u786e\u957f\u5bbd\u5c3a\u5bf8 + \u662f\u5426\u6709L\u578b\/T\u578b\/\u72ec\u7acb\u9910\u5385<\/td><td>\u5224\u65ad\u65b9\u6848A\uff08\u53cc\u5185\u673a\uff09\u8fd8\u662f\u65b9\u6848B\uff08\u5355\u5185\u673a\uff09\u66f4\u5408\u9002<\/td><\/tr><tr><td>2<\/td><td>\u5916\u673a\u4f4d\u5c3a\u5bf8\uff08\u9ad8\u00d7\u5bbd\u00d7\u6df1\uff09<\/td><td>\u786e\u8ba4\u8212\u4eab180\u5355\u98ce\u6247\u673a\u4f4d\u662f\u5426\u8db3\u591f<\/td><\/tr><tr><td>3<\/td><td>\u786e\u8ba4\u662f\u5426\u9700\u8981PE\u51c0\u5316\u6a21\u5757\uff08\u513f\u7ae5\u623f\u5efa\u8bae\u52a0\u88c5\uff09<\/td><td>\u9488\u5bf9\u9f3b\u708e\u95ee\u9898\u7684\u5f3a\u5316\u65b9\u6848<\/td><\/tr><tr><td>4<\/td><td>\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>\u786e\u4fdd\u65b9\u6848\u4e07\u65e0\u4e00\u5931<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6536\u5230\u4e0a\u8ff0\u4fe1\u606f\u540e\uff0c\u6211\u4eec\u5c06\u4e3a\u60a8\u751f\u6210\u5305\u542b\u7cbe\u786e\u5185\u673a\u578b\u53f7\u3001\u8d85\u914d\u7387\u6838\u7b97\u3001\u65bd\u5de5\u6807\u51c6\u7684\u300a\u6b63\u5f0f\u65b9\u6848\u4e66\u300b\u3002<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5341\u3001\u6211\u4eec\u7684\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u627f\u8bfa\u9879<\/strong><\/td><td><strong>\u5185\u5bb9<\/strong><\/td><\/tr><tr><td><strong>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/strong><\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td><strong>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/strong><\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848\uff08A\u4e0eB\uff09<\/td><\/tr><tr><td><strong>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/strong><\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><\/tr><tr><td><strong>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/strong><\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td><strong>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/strong><\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td><strong>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/strong><\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u6696\u901a \u00b7 \u4e13\u6ce8\u4ee5\u79d1\u5b66\u8bbe\u8ba1\u5339\u914d\u771f\u5b9e\u751f\u6d3b<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\u59d3\u540d\uff1a\u5f90\u5148\u751f \u65b9\u6848\u65e5\u671f\uff1a2026\u5e745 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-953","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=953\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5ba2\u6237\u59d3\u540d\uff1a\u5f90\u5148\u751f \u65b9\u6848\u65e5\u671f\uff1a2026\u5e745 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=953\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-19T09:15:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953\",\"name\":\"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/05-1.png\",\"datePublished\":\"2026-05-18T09:26:12+00:00\",\"dateModified\":\"2026-05-19T09:15:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/05-1.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/05-1.png\",\"width\":793,\"height\":595},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=953#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=953","og_locale":"zh_CN","og_type":"article","og_title":"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u5ba2\u6237\u59d3\u540d\uff1a\u5f90\u5148\u751f \u65b9\u6848\u65e5\u671f\uff1a2026\u5e745 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=953","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-19T09:15:37+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"7 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=953","url":"https:\/\/longmai-nt.com\/?page_id=953","name":"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=953#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=953#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png","datePublished":"2026-05-18T09:26:12+00:00","dateModified":"2026-05-19T09:15:37+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=953#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=953"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=953#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/05-1.png","width":793,"height":595},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=953#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e91\u749f\u6797\u8457\u5f90\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u65b0\u98ce\u65b9\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/953","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=953"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/953\/revisions"}],"predecessor-version":[{"id":1033,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/953\/revisions\/1033"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=953"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}