{"id":982,"date":"2026-05-18T18:18:04","date_gmt":"2026-05-18T10:18:04","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=982"},"modified":"2026-05-27T18:53:06","modified_gmt":"2026-05-27T10:53:06","slug":"%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a-%c2%b7-%e6%b9%96%e4%b8%8e%e7%99%bd%e7%ae%a1%e8%80%81%e5%b8%88%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%9610%e5%b9%b4%e8%83%bd%e6%ba%90%e4%bf%9d%e9%9a%9c","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=982","title":{"rendered":"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\"><strong>\u6863\u6848\u7f16\u53f7<\/strong>\uff1aB-B-W-H-001<br><strong>\u5ba2\u6237<\/strong>\uff1a\u7ba1\u8001\u5e08<br><strong>\u9879\u76ee\u5730\u5740<\/strong>\uff1a\u6e56\u4e0e\u767d<br><strong>\u91c7\u6696\u9762\u79ef<\/strong>\uff1a93\u33a1<br><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u8303\u4e3d\u5982<br><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670818\u65e5<br><strong>\u7248\u672c<\/strong>\uff1aV3.0\uff08\u6863\u6848\u7248\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/strong>\uff1a\u4e3a\u7ba1\u8001\u5e08\u4ea4\u4ed8\u4e00\u5957\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u7684\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u7cfb\u7edf\u300293\u33a1\u5730\u6696\u5b63\u91c7\u6696\u8d39\u7528\u76ee\u6807\u22642,800\u5143\uff0c\u5173\u7a97\u7761\u89c9\u4e0d\u95f7\uff0c\u7a7a\u6c14\u8d28\u91cf\u53ef\u89c6\u5316\uff0c\u5168\u7a0b\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u65bd\u5de5\uff0c\u6863\u6848\u53ef\u8ffd\u6eaf\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">\u76ee\u5f55<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#yjd01\">\u4e00\u9636\u6bb5\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/a><\/h4>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd011\">1\u3001\u9700\u6c42\u7406\u89e3<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd012\">2\u3001\u914d\u7f6e\u603b\u89c8<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd013\">3\u3001\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd014\">4\u3001\u5730\u6696\u7cfb\u7edf<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd015\">5\u3001\u65b0\u98ce\u7cfb\u7edf<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd016\">6\u3001\u4f1a\u5458\u6743\u76ca<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd017\">7\u3001\u4e13\u9879\u627f\u8bfa<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd018\">8\u3001\u7b7e\u7ea6\u540e\u6743\u76ca<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd019\">9\u3001\u670d\u52a1\u627f\u8bfa<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd10\">10\u3001\u603b\u7ed3<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd02\">\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd021\">1\u3001\u6982\u8ff0<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">1.1\u3001\u9879\u76ee\u4fe1\u606f<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">1.2\u3001\u8bbe\u8ba1\u4f9d\u636e<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">1.3\u3001\u5907\u6ce8\u8bf4\u660e<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd022\">2\u3001\u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de56\u6b65\u6cd5+2<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.1 \u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.2 \u7b2c\u4e8c\u6b65\uff1a\u8bbe\u8ba1\u51fa\u56fe<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd0223\">2.3 \u7b2c\u4e09\u6b65\uff1a\u9690\u853d\u5de5\u7a0b\u7cbe\u5de56\u6b65\u6cd5\uff08\u5b9a\u4f4d+\u6e05\u5355\u9a8c\u6536+\u6309\u56fe\u65bd\u5de5+\u6807\u51c6\u5de5\u827a+\u76d1\u7406+\u4e09\u65b9\u9a8c\u6536\uff09<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.4 \u7b2c\u56db\u6b65\uff1a\u76d1\u7406\u5230\u4f4d<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.5 \u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.6 \u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536\uff08\u542b\u8c03\u8bd5\u9a8c\u6536\u5355\uff09<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.7 +1\uff1a\u4ea4\u4ed8\u6559\u5b66\uff08\u542b\u64cd\u4f5c\u8981\u70b9\u901f\u67e5\uff09<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">2.8 +2\uff1a\u552e\u540e\u4fdd\u969c\uff08\u542b\u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355\uff09<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd03\">\u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd031\">1\u3001\u5ba2\u6237\u53cd\u9988<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd032\">2\u3001\u80fd\u8017\u8ddf\u8e2a\u4e0e\u89e3\u6790 \u5f85\u5e74\u5ea6\u6570\u636e\u5f55\u5165\u3002<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"#yjd033\">3\u3001\u552e\u540e\u670d\u52a1\u8bb0\u5f55\u4e0e\u89e3\u6790<\/a><\/h5>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"yjd01\" class=\"wp-block-heading\">\u4e00\u9636\u6bb5\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1\uff08\u65b9\u6848\u524d\u4e66\uff09<\/h2>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u4e00\u9636\u6bb51~10\u70b9\u51fb\u770b\u5b8c\u6574\u7248\u2192<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-1\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 id=\"yjd011\" class=\"wp-block-heading\">\u7b2c\u4e00\u90e8\u5206\uff1a\u60a8\u7684\u9700\u6c42\u7406\u89e3<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u8bf4\u7684<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7406\u89e3\u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u5c31\u6015\u566a\u97f3\u5927\uff0c\u5f71\u54cd\u7761\u7720\u201d<\/td><td>\u5367\u5ba4\u7a7a\u8c03+\u65b0\u98ce\u8fd0\u884c\u65f6\u4e0d\u80fd\u6709\u98ce\u58f0\uff0c\u4fdd\u8bc1\u6574\u665a\u5b89\u9759\u7761\u7720<\/td><\/tr><tr><td>\u201c\u540e\u671f\u80fd\u8017\u9ad8\uff0c\u8d39\u7535\u201d<\/td><td>\u6015\u201c\u4e70\u5f97\u8d77\u7528\u4e0d\u8d77\u201d\uff0c\u62c5\u5fc3\u6bcf\u6708\u7535\u8d39\/\u71c3\u6c14\u8d39\u8d85\u51fa\u9884\u671f<\/td><\/tr><tr><td>\u201c\u5bf9\u7a7a\u6c14\u8d28\u91cf\u8981\u6c42\u9ad8\u201d<\/td><td>\u65b0\u88c5\u4fee\u62c5\u5fc3\u7532\u919b\u3001PM2.5\uff0c\u5173\u7a97\u7761\u89c9\u4e0d\u95f7\uff0c\u9700\u8981\u65b0\u98ce<\/td><\/tr><tr><td>\u201c\u627e\u4e00\u5bb6\u6709\u4fdd\u8bc1\u3001\u4e13\u4e1a\u7684\u516c\u53f8\u201d<\/td><td>\u9700\u8981\u6b63\u89c4\u6388\u6743\u3001\u53ef\u8ffd\u6eaf\u7684\u8d44\u8d28\uff0c\u5b89\u88c5\u56e2\u961f\u6301\u8bc1\u4e0a\u5c97<\/td><\/tr><tr><td>\u201c\u5b89\u88c5\u56e2\u961f\u6709\u7ecf\u9a8c\u3001\u6709\u6388\u6743\u3001\u65e5\u7acb\u57f9\u8bad\u201d<\/td><td>\u76f8\u4fe1\u201c\u4e09\u5206\u8bbe\u5907\u4e03\u5206\u5b89\u88c5\u201d\uff0c\u5de5\u827a\u6bd4\u8bbe\u5907\u54c1\u724c\u66f4\u91cd\u8981<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u672c\u65b9\u6848\u7684\u6838\u5fc3\u627f\u8bfa<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u2705&nbsp;<strong>\u9759\u97f3<\/strong>\uff1a\u5185\u673a\u6700\u4f4e18dB + \u65b0\u98ce\u6700\u4f4e23dB\uff0c\u6bd4\u56fe\u4e66\u9986\u5b89\u9759<\/li>\n\n\n\n<li>\u2705&nbsp;<strong>\u8282\u80fd<\/strong>\uff1a\u8d85\u914d\u7387\u5408\u7406+\u51b7\u51dd\u7089+\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e09\u91cd\u7701\u7535<\/li>\n\n\n\n<li>\u2705&nbsp;<strong>\u5065\u5eb7<\/strong>\uff1a\u65b0\u98cePM2.5\u8fc7\u6ee4\u226598% + \u7a7a\u8c03\u81ea\u6e05\u6d01\uff0c\u5168\u5c4b\u6d01\u51c0\u7a7a\u6c14<\/li>\n\n\n\n<li>\u2705&nbsp;<strong>\u4e13\u4e1a<\/strong>\uff1a\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546+\u7279\u9080\u5b89\u88c5\u5355\u4f4d<\/li>\n\n\n\n<li>\u2705&nbsp;<strong>\u4fdd\u969c<\/strong>\uff1a\u5b89\u88c5\u56e2\u961f\u6301\u8bc1\u4e0a\u5c97\uff0c5\u5e74\u5de5\u7a0b\u8d28\u4fdd<\/li>\n<\/ul>\n\n\n\n<h3 id=\"yjd012\" class=\"wp-block-heading\">\u7b2c\u4e8c\u90e8\u5206\uff1a\u914d\u7f6e\u603b\u89c8<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u914d\u7f6e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u7279\u70b9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u4e2d\u592e\u7a7a\u8c03<\/strong><\/td><td>VAM mini\u2161 160\u4e00\u62d6\u516d<\/td><td>\u6da1\u65cb\u538b\u7f29\u673a\uff0c\u9002\u5408\u5e38\u5f00\u591a\u53f0\uff0c\u9759\u97f3\u8282\u80fd<\/td><\/tr><tr><td><strong>\u5730\u6696<\/strong><\/td><td>\u745e\u7f8e\u51b7\u51dd\u708924kW + 93\u33a1\u963b\u6c27\u5730\u6696<\/td><td>\u5168\u9884\u6df7\u51b7\u51dd\uff0c\u70ed\u6548\u7387108%\uff0c\u4f4e\u6e29\u8fd0\u884c\u8282\u80fd<\/td><\/tr><tr><td><strong>\u65b0\u98ce<\/strong><\/td><td>\u65e5\u7acb\u5929\u51c0\u667a\u6167\u578b350<\/td><td>\u5168\u70ed\u4ea4\u6362\u6548\u738765%\uff0cPM2.5\u8fc7\u6ee4\u226598%\uff0c\u6700\u4f4e23dB<\/td><\/tr><tr><td><strong>\u63a7\u5236<\/strong><\/td><td>\u5ba4\u6e29\u8054\u52a8+WiFi\u7ebf\u63a7+\u65b0\u98ce\u5f69\u5c4f<\/td><td>\u6309\u9700\u8fd0\u884c\uff0c\u675c\u7edd\u6d6a\u8d39<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"yjd013\" class=\"wp-block-heading\">\u7b2c\u4e09\u90e8\u5206\uff1a\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\uff08VAM mini\u2161 160\u4e00\u62d6\u516d\uff09<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">3.1 \u914d\u7f6e\u6e05\u5355<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-71FSVNAQD\/P<\/td><td>7.1kW<\/td><td>1\u53f0<\/td><td>\u5927\u51b7\u91cf\uff0c\u4fdd\u969c\u6548\u679c<\/td><\/tr><tr><td>\u4e3b\u5367<\/td><td>RPIZ-40FSVNAQD\/P<\/td><td>4.0kW<\/td><td>1\u53f0<\/td><td><strong>\u9759\u97f318dB<\/strong><\/td><\/tr><tr><td>\u6b21\u53671<\/td><td>RPIZ-32FSVNAQD\/P<\/td><td>3.2kW<\/td><td>1\u53f0<\/td><td>\u9759\u97f318dB<\/td><\/tr><tr><td>\u6b21\u53672<\/td><td>RPIZ-22FSVAQD\/P<\/td><td>2.2kW<\/td><td>1\u53f0<\/td><td>\u9759\u97f318dB<\/td><\/tr><tr><td>\u4e66\u623f<\/td><td>RPIZ-18FSVNAQD\/P<\/td><td>1.8kW<\/td><td>1\u53f0<\/td><td>\u9759\u97f318dB<\/td><\/tr><tr><td>\u6b21\u53673<\/td><td>RPIZ-18FSVNAQD\/P<\/td><td>1.8kW<\/td><td>1\u53f0<\/td><td>\u9759\u97f318dB<\/td><\/tr><tr><td><strong>\u5916\u673a<\/strong><\/td><td>RAS-160FSVN8Q<\/td><td>15.5kW<\/td><td>1\u53f0<\/td><td>VAM mini\u2161\uff0c\u6da1\u65cb\u538b\u7f29\u673a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.2 \u6838\u5fc3\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u60a8\u7684\u4ef7\u503c<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673aAPF<\/td><td>5.75\uff08\u8d85\u4e00\u7ea7\uff09<\/td><td>\u957f\u671f\u7701\u7535<\/td><\/tr><tr><td>\u5185\u673a\u6700\u4f4e\u566a\u97f3<\/td><td><strong>18 dB(A)<\/strong><\/td><td>\u6bd4\u56fe\u4e66\u9986\uff0830dB\uff09\u5b89\u9759<\/td><\/tr><tr><td>\u8d85\u914d\u7387<\/td><td>129.7%<\/td><td>\u5408\u7406\u533a\u95f4\uff0c\u5168\u5f00\u6709\u4fdd\u969c<\/td><\/tr><tr><td>\u6807\u914d\u529f\u80fd<\/td><td>\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6d88\u6bd2+\u63d0\u5347\u6cf5<\/td><td>\u51fa\u98ce\u6d01\u51c0\u3001\u675c\u7edd\u6f0f\u6c34<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.3 \u7a7a\u8c03\u62a5\u4ef7\uff08VAM mini\u2161\u7cfb\u52178\u6298\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673a<\/td><td>RAS-160FSVN8Q<\/td><td>1\u53f0<\/td><td>22,525\u5143<\/td><\/tr><tr><td>\u5185\u673a71<\/td><td>RPIZ-71FSVNAQD\/P<\/td><td>1\u53f0<\/td><td>3,888\u5143<\/td><\/tr><tr><td>\u5185\u673a40<\/td><td>RPIZ-40FSVNAQD\/P<\/td><td>1\u53f0<\/td><td>3,388\u5143<\/td><\/tr><tr><td>\u5185\u673a32<\/td><td>RPIZ-32FSVNAQD\/P<\/td><td>1\u53f0<\/td><td>3,263\u5143<\/td><\/tr><tr><td>\u5185\u673a22<\/td><td>RPIZ-22FSVAQD\/P<\/td><td>1\u53f0<\/td><td>3,013\u5143<\/td><\/tr><tr><td>\u5185\u673a18<\/td><td>RPIZ-18FSVNAQD\/P<\/td><td>2\u53f0<\/td><td>2,888\u5143<\/td><\/tr><tr><td><strong>\u7a7a\u8c03\u5c0f\u8ba1<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u2705 \u542b\u8bbe\u5907\u3001\u5b89\u88c5\u3001WiFi\u7ebf\u63a7\u5668\u00d76\u3001\u6240\u6709\u8f85\u6750<\/p>\n<\/blockquote>\n\n\n\n<h3 id=\"yjd014\" class=\"wp-block-heading\">\u7b2c\u56db\u90e8\u5206\uff1a\u5730\u6696\u7cfb\u7edf\uff08\u745e\u7f8e\u51b7\u51dd\u7089+93\u33a1\u963b\u6c27\u5730\u6696\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u914d\u7f6e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u9505\u7089<\/td><td>\u745e\u7f8e\u51b7\u51dd\u708924kW<\/td><td>\u5168\u9884\u6df7\u51b7\u51dd\uff0c\u70ed\u6548\u7387108%\uff0c\u6700\u5c0f\u8f93\u51fa3-4kW<\/td><\/tr><tr><td>\u4e3b\u7ba1<\/td><td>\u4f1f\u661fDe32\u963b\u6c27\u7ba1<\/td><td>\u6d41\u91cf\u5145\u8db3<\/td><\/tr><tr><td>\u76d8\u7ba1<\/td><td>\u4f1f\u661fDe20 PE-RT\u963b\u6c27\u7ba1<\/td><td>5\u5c42\u963b\u6c27\uff0c\u8d28\u4fdd50\u5e74<\/td><\/tr><tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u4f1f\u661f\u94dc\u8d28\u4e00\u4f53\u953b\u9020<\/td><td>\u5e26\u6d41\u91cf\u8c03\u8282<\/td><\/tr><tr><td>\u63a7\u5236<\/td><td>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8<\/td><td>\u7701\u6c1410-25%<\/td><\/tr><tr><td>\u4fdd\u6e29<\/td><td>\u4f1f\u661f\u767d\u6676\u677f+\u955c\u9762\u53cd\u5c04\u819c<\/td><td>\u51cf\u5c11\u70ed\u635f\u5931<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u745e\u7f8e\u51b7\u51dd\u708924kW<\/td><td>1\u53f0<\/td><td>11,500\u5143<\/td><\/tr><tr><td>\u5730\u6696\u6750\u6599+\u5b89\u88c5<\/td><td>93\u33a1<\/td><td>11,160\u5143<\/td><\/tr><tr><td>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u5668<\/td><td>1\u5957<\/td><td>980\u5143<\/td><\/tr><tr><td>\u56de\u586b\u627e\u5e73<\/td><td>93\u33a1<\/td><td>4,650\u5143<\/td><\/tr><tr><td><strong>\u5730\u6696\u5c0f\u8ba1<\/strong><\/td><td>\u2014<\/td><td><strong>28,290\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"yjd015\" class=\"wp-block-heading\">\u7b2c\u4e94\u90e8\u5206\uff1a\u65b0\u98ce\u7cfb\u7edf\uff08\u65e5\u7acb\u5929\u51c0\u667a\u6167\u578b350\uff09<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">5.1 \u6838\u5fc3\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u60a8\u7684\u4ef7\u503c<\/th><\/tr><\/thead><tbody><tr><td>\u65b0\u98ce\u91cf<\/td><td>350 m\u00b3\/h<\/td><td>\u6ee1\u8db393\u33a1\u5168\u5c4b\u6362\u6c14<\/td><\/tr><tr><td>\u5168\u70ed\u4ea4\u6362\u6548\u7387\uff08\u5236\u70ed\uff09<\/td><td><strong>65%<\/strong><\/td><td>\u51ac\u5929\u6696\u6c14\u4e0d\u88ab\u65b0\u98ce\u5e26\u8d70\uff0c\u7701\u6c14<\/td><\/tr><tr><td>PM2.5\u8fc7\u6ee4\u6548\u7387<\/td><td><strong>\u226598%<\/strong><\/td><td>\u96fe\u973e\u5929\u4e5f\u80fd\u5f00\u65b0\u98ce<\/td><\/tr><tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td><strong>\u6700\u4f4e23dB<\/strong><\/td><td>\u6bd4\u843d\u53f6\u58f0\u8fd8\u8f7b<\/td><\/tr><tr><td>\u4e94\u7ef4\u4f20\u611f\u5668<\/td><td>\u6e29\/\u6e7f\/PM2.5\/CO\u2082\/TVOC<\/td><td>\u7a7a\u6c14\u8d28\u91cf\u53ef\u89c6\u5316<\/td><\/tr><tr><td>\u63a7\u5236<\/td><td>\u9ad8\u6e05\u5f69\u5c4fWiFi\u7ebf\u63a7\u5668<\/td><td>APP\u8fdc\u7a0b\u63a7\u5236<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.2 \u65b0\u98ce\u62a5\u4ef7<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u5929\u51c0\u65b0\u98ce350<\/td><td>KPI-3521Q5\/F<\/td><td>9,500\u5143<\/td><td>6,200\u5143<\/td><td><strong>15,700\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"yjd016\" class=\"wp-block-heading\">\u7b2c\u516d\u90e8\u5206\uff1a\u4f1a\u5458\u6743\u76ca\uff08199\u5143\/\u5e74\uff0c\u9996\u5e74\u53ef\u7528\u6696\u901a\u91d1\u989d\u62b5\u6263\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u76ca<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td>\u8212\u4eab\/\u5168\u6548\/\u522b\u5885\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u670d\u52a1\u6298\u6263<\/td><td>\u6240\u6709\u670d\u52a1\u53ca\u8017\u67505-8\u6298<\/td><\/tr><tr><td>\u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8<\/td><td>\u4e0d\u9650\u6b21\u6570<\/td><\/tr><tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/td><\/tr><tr><td>10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"yjd017\" class=\"wp-block-heading\">\u7b2c\u4e03\u90e8\u5206\uff1a\u9488\u5bf9\u60a8\u75db\u70b9\u7684\u4e13\u9879\u627f\u8bfa<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u7684\u75db\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u51b3\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6548\u679c\u627f\u8bfa<\/th><\/tr><\/thead><tbody><tr><td><strong>\u566a\u97f3\u5927<\/strong><\/td><td>\u5185\u673a\u6700\u4f4e18dB + \u65b0\u98ce\u6700\u4f4e23dB<\/td><td>\u5367\u5ba4\u591c\u95f4\u226420dB<\/td><\/tr><tr><td><strong>\u80fd\u8017\u9ad8<\/strong><\/td><td>\u51b7\u51dd\u7089+\u5ba4\u6e29\u8054\u52a8+\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/td><td>93\u33a1\u5730\u6696\u5b63\u22642,800\u5143<\/td><\/tr><tr><td><strong>\u7a7a\u6c14\u8d28\u91cf<\/strong><\/td><td>\u65b0\u98cePM2.5\u8fc7\u6ee4\u226598% + \u7a7a\u8c03\u81ea\u6e05\u6d01<\/td><td>\u5173\u7a97\u7761\u89c9\u4e0d\u95f7<\/td><\/tr><tr><td><strong>\u4e13\u4e1a\u4fdd\u8bc1<\/strong><\/td><td>\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/td><td>\u5b98\u7f51\u53ef\u67e5<\/td><\/tr><tr><td><strong>\u5b89\u88c5\u56e2\u961f<\/strong><\/td><td>\u65e5\u7acb\u57f9\u8bad\u4e0a\u5c97\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/td><td>\u5168\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"yjd018\" class=\"wp-block-heading\">\u7b2c\u516b\u90e8\u5206\uff1a\u7b7e\u7ea6\u540e\u60a8\u5c06\u62e5\u6709<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u4e0d\u662f\u5e7f\u544a\u3002\u8fd9\u662f\u771f\u5b9e\u5ba2\u6237\u7684\u6863\u6848\u793a\u4f8b\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7b7e\u7ea6\u540e\uff0c\u60a8\u4e5f\u4f1a\u62e5\u6709\u8fd9\u6837\u4e00\u4efd\u4e13\u5c5e\u6863\u6848\u2014\u2014\u4ece\u65bd\u5de5\u7167\u7247\u5230\u9a8c\u6536\u5355\u5230\u6bcf\u5e74\u80fd\u8017\u6570\u636e\uff0c\u5168\u90e8\u516c\u5f00\u900f\u660e\uff0c\u5b98\u7f51\u53ef\u67e5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcce&nbsp;<strong>\u67e5\u770b\u771f\u5b9e\u6863\u6848\u793a\u4f8b<\/strong>\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=599\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/longmai-nt.com\/?page_id=599<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6863\u6848\u5305\u542b<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u5168\u6d41\u7a0b\u7167\u7247\u8bb0\u5f55<\/li>\n\n\n\n<li>\u8bbe\u5907\u6750\u6599\u6e05\u5355<\/li>\n\n\n\n<li>\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355<\/li>\n\n\n\n<li>\u6bcf\u5e74\u80fd\u8017\u6570\u636e\uff08\u6301\u7eed\u8ddf\u8e2a10\u5e74\uff09<\/li>\n\n\n\n<li>\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/li>\n<\/ul>\n\n\n\n<h3 id=\"yjd019\" class=\"wp-block-heading\">\u7b2c\u4e5d\u90e8\u5206\uff1a\u670d\u52a1\u627f\u8bfa<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\u6807\u51c6\u65bd\u5de5<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6+\u4e09\u9053\u5bc6\u5c01\u5de5\u827a<\/td><\/tr><tr><td>\u900f\u660e\u62a5\u4ef7<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td>10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u51fa\u5177\u5206\u6790\u62a5\u544a<\/td><\/tr><tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>199\u5143\/\u5e74\u4eab5-8\u6298\u670d\u52a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"yjd10\" class=\"wp-block-heading\">\u7b2c\u5341\u90e8\u5206\uff1a\u603b\u7ed3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u5957\u65b9\u6848\u4e00\u6b21\u6027\u89e3\u51b3\u4e86\u60a8\u5173\u5fc3\u7684\u6240\u6709\u95ee\u9898\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u7684\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7b54\u6848<\/th><\/tr><\/thead><tbody><tr><td>\u566a\u97f3\u5927\uff1f<\/td><td>\u5185\u673a18dB+\u65b0\u98ce23dB\uff0c\u6bd4\u56fe\u4e66\u9986\u5b89\u9759<\/td><\/tr><tr><td>\u80fd\u8017\u9ad8\uff1f<\/td><td>\u51b7\u51dd\u7089+\u8054\u52a8+\u5168\u70ed\u4ea4\u6362\uff0c\u6bcf\u5e74\u7701\u7ea6900\u5143<\/td><\/tr><tr><td>\u7a7a\u6c14\u5dee\uff1f<\/td><td>\u65b0\u98cePM2.5\u8fc7\u6ee4\u226598%+\u81ea\u6e05\u6d01<\/td><\/tr><tr><td>\u4e0d\u4e13\u4e1a\uff1f<\/td><td>\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u5b98\u7f51\u53ef\u67e5<\/td><\/tr><tr><td>\u5b89\u88c5\u6ca1\u4fdd\u969c\uff1f<\/td><td>\u6301\u8bc1\u4e0a\u5c97\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5+2\uff0c\u5168\u7a0b\u5b58\u6863<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9884\u8ba1\u4f18\u60e0\u540e\u5b9e\u4ed8\u4ef7\uff1a\u7ea681,300\u5143<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08\u542b\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce+\u6240\u6709\u5b89\u88c5\u8f85\u6750+5\u5e74\u8d28\u4fdd+10\u5e74\u80fd\u8017\u8ddf\u8e2a\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e0b\u4e00\u6b65<\/strong>\uff1a\u5b89\u6392\u5de5\u7a0b\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u65b0\u98ce\u7ba1\u8def\u8d70\u5411\u3001\u98ce\u53e3\u4f4d\u7f6e\uff0c\u51fa\u5177\u7cbe\u786e\u5408\u540c\u4ef7\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u6696\u901a\u987e\u95ee<\/strong>\uff1a\u8303\u4e3d\u5982<br><strong>\u8054\u7cfb\u7535\u8bdd<\/strong>\uff1a<a href=\"tel:13398198375\">13398198375<\/a><br><strong>\u95e8\u5e97\u5730\u5740<\/strong>\uff1a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986\u4e09\u697cA-348<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002\u671f\u5f85\u4e3a\u60a8\u670d\u52a1<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"yjd02\" class=\"wp-block-heading\">\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1\u3001\u6982\u8ff0\uff1a\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u914d\u7f6e\u6750\u6599\u6e05\u5355\u53ca\u8bbe\u8ba1\u8bf4\u660e<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886801-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u914d\u7f6e\u00b7\u5730\u6696\u914d\u7f6e\" class=\"wp-image-996\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886801-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886801-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886801-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886801-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886801-2048x1536.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886802-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u914d\u7f6e\u00b7\u5730\u6696\u6750\u6599\u6e05\u5355\" class=\"wp-image-997\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886802-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886802-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886802-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886802-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u914d\u7f6e\u886802-2048x1536.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886801-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u914d\u7f6e\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u914d\u7f6e\" class=\"wp-image-998\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886801-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886801-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886801-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886801-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886801.jpeg 1984w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886802-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u914d\u7f6e\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\" class=\"wp-image-999\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886802-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886802-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886802-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886802-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u914d\u7f6e\u886802.jpeg 1851w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u914d\u7f6e\u886801-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u914d\u7f6e\u00b7\u65e5\u7acb\u65b0\u98ce\u914d\u7f6e\" class=\"wp-image-1000\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u914d\u7f6e\u886801-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u914d\u7f6e\u886801-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u914d\u7f6e\u886801-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u914d\u7f6e\u886801-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u914d\u7f6e\u886801-2048x1536.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">1.1\u3001\u914d\u7f6e\u6750\u6599\u6e05\u5355<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e2d\u592e\u7a7a\u8c03\u90e8\u5206\uff08\u65e5\u7acb\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u54c1\u724c<\/strong><\/td><td><strong>\u540d\u79f0<\/strong><\/td><td><strong>\u89c4\u683c\u578b\u53f7<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><td><strong>\u5355\u4f4d<\/strong><\/td><td><strong>\u5355\u4ef7\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5408\u8ba1\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5907\u6ce8<\/strong><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u7a7a\u6c14\u6e90\u70ed\u6cf5\u5ba4\u5916\u673a<\/td><td>RAS-160FSVN8Q<\/td><td>1<\/td><td>\u53f0<\/td><td>26580<\/td><td>26580<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-71FSVNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>9040<\/td><td>9040<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-32FSVNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>8450<\/td><td>8450<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-40FSVNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>8450<\/td><td>8450<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-22FSVNAQD\/P<\/td><td>1<\/td><td>\u53f0<\/td><td>8190<\/td><td>8190<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>DC\u8584\u578b\u98ce\u7ba1\u5f0f\u5ba4\u5185\u673a<\/td><td>RPIZ-18FSVNAQD\/P<\/td><td>2<\/td><td>\u53f0<\/td><td>7930<\/td><td>15860<\/td><td><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u9ad8\u6e05\u5f69\u5c4fWiFi\u7ebf\u63a7\u5668<\/td><td>PC-P1HPQA<\/td><td>6<\/td><td>\u4e2a<\/td><td>275<\/td><td>1650<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u5907\u5408\u8ba1\uff1a78220 \u5143<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u54c1\u724c<\/strong><\/td><td><strong>\u540d\u79f0<\/strong><\/td><td><strong>\u89c4\u683c\u578b\u53f7<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><td><strong>\u5355\u4f4d<\/strong><\/td><td><strong>\u529f\u80fd<\/strong><\/td><td><strong>\u5907\u6ce8<\/strong><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>ABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u51fa\u98ce\u53e3\uff09<\/td><td>400\u00d7150<\/td><td>4<\/td><td>\u4e2a<\/td><td>\u4fa7\u9001\u98ce<\/td><td><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>ABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u51fa\u98ce\u53e3\uff09<\/td><td>540\u00d7150<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u4fa7\u9001\u98ce<\/td><td>\u52a0\u957f\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>ABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u51fa\u98ce\u53e3\uff09<\/td><td>1050\u00d7150<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u4fa7\u9001\u98ce<\/td><td><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>ABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u56de\u98ce\u53e3\uff09<\/td><td>800\u00d7280<\/td><td>4<\/td><td>\u4e2a<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><td><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>ABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u56de\u98ce\u53e3\uff09<\/td><td>1000\u00d7280<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><td>\u52a0\u957f\u53e6\u8ba1<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>ABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u56de\u98ce\u53e3\uff09<\/td><td>1500\u00d7280<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><td><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\/<\/td><td>\/<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3<\/td><td><\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750\uff08\u80f6\u6c34\u3001\u540a\u7b4b\u7b49\uff09<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\/<\/td><td>\/<\/td><td>\u5b89\u88c5\u56fa\u5b9a<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u98ce\u7cfb\u7edf\u5408\u8ba1\uff1a0 \u5143\uff08\u5305\u5de5\u5305\u6599\uff09<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">\u5730\u6696\u90e8\u5206\uff08\u745e\u7f8e\u71c3\u6c14\u58c1\u6302\u7089\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9505\u7089\u53ca\u63a7\u5236\u7cfb\u7edf<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u54c1\u724c<\/strong><\/td><td><strong>\u540d\u79f0<\/strong><\/td><td><strong>\u578b\u53f7\u89c4\u683c<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><td><strong>\u5355\u4f4d<\/strong><\/td><td><strong>\u5355\u4ef7\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5408\u8ba1\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5907\u6ce8<\/strong><\/td><\/tr><tr><td>\u745e\u7f8e<\/td><td>\u71c3\u6c14\u58c1\u6302\u7089<\/td><td>LL1GBQ24-CBX1-30<\/td><td>1<\/td><td>\u53f0<\/td><td>19999<\/td><td>19999<\/td><td>766\u00d7450\u00d7277<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u8054\u52a8\u63a7\u5236<\/td><td>\u65e0\u7ebf\u63a7\u5236<\/td><td>1<\/td><td>\u5957<\/td><td>980<\/td><td>980<\/td><td>\u5ba4\u6e29\u8054\u52a8\u9505\u7089\u542f\u505c<\/td><\/tr><tr><td>\u56fd\u4ea7<\/td><td>F1\u4fdd\u62a4\u5242+\u71c3\u6c14\u8fc7\u6ee4\u5668<\/td><td>\/<\/td><td>1<\/td><td>\u9879<\/td><td>180<\/td><td>180<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5c0f\u8ba1\uff1a21159 \u5143<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3b\u7ba1\u7cfb\u7edf<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u54c1\u724c<\/strong><\/td><td><strong>\u540d\u79f0<\/strong><\/td><td><strong>\u578b\u53f7\u89c4\u683c<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><td><strong>\u5355\u4f4d<\/strong><\/td><td><strong>\u5355\u4ef7\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5408\u8ba1\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5907\u6ce8<\/strong><\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>F-PPR\u7ea4\u7ef4\u590d\u5408\u7ba1<\/td><td>De32\u00d74.4<\/td><td>25<\/td><td>m<\/td><td>37.5<\/td><td>938<\/td><td>\u9505\u7089\u5230\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d832<\/td><td>25<\/td><td>m<\/td><td>9<\/td><td>225<\/td><td>\u7ba1\u9053\u4fdd\u6e29<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u5668\u7bb1<\/td><td>500\u00d7500\u00d7120<\/td><td>1<\/td><td>\u4e2a<\/td><td>462<\/td><td>462<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PPR\u89d2\u5f0f\u7403\u9600<\/td><td>DN25<\/td><td>2<\/td><td>\u4e2a<\/td><td>49.5<\/td><td>99<\/td><td>\u901a\u65ad\u6c34\u6d41<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u94dc\u8d28\u5206\u96c6\u6c34\u5668<\/td><td>DN25\uff0c7\u8def<\/td><td>7<\/td><td>\u8def<\/td><td>234<\/td><td>1638<\/td><td>\u5206\u8def\u63a7\u5236<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668\u672b\u7aef\u5c3e\u4ef6<\/td><td>DN15<\/td><td>1<\/td><td>\u5957<\/td><td>108<\/td><td>108<\/td><td>\u6392\u6c14\u9600+\u6cc4\u6c34\u9600+\u538b\u529b\u8868<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\u3001\u5f2f\u5934\u7b49<\/td><td>1<\/td><td>\u9879<\/td><td>150<\/td><td>150<\/td><td>\u8fde\u63a5\u7ba1\u9053<\/td><\/tr><tr><td>\u65b0\u754c<\/td><td>\u751f\u6d3b\u70ed\u6c34\u5faa\u73af\u6cf5<\/td><td>\/<\/td><td>1<\/td><td>\u5957<\/td><td>2000<\/td><td>2000<\/td><td>\u987e\u5ba2\u81ea\u9009\uff0c\u4e0d\u8ba1\u5165\u5408\u540c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5c0f\u8ba1\uff08\u4e0d\u542b\u5faa\u73af\u6cf5\uff09\uff1a3620 \u5143<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u76d8\u7ba1\u7cfb\u7edf<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u54c1\u724c<\/strong><\/td><td><strong>\u540d\u79f0<\/strong><\/td><td><strong>\u578b\u53f7\u89c4\u683c<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><td><strong>\u5355\u4f4d<\/strong><\/td><td><strong>\u5355\u4ef7\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5408\u8ba1\uff08\u5143\uff09<\/strong><\/td><td><strong>\u5907\u6ce8<\/strong><\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d72.0<\/td><td>400.244<\/td><td>m<\/td><td>10.2<\/td><td>4082<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c<\/td><td>50g<\/td><td>93.08<\/td><td>m\u00b2<\/td><td>5.3<\/td><td>493<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f<\/td><td>2cm<\/td><td>93.08<\/td><td>m\u00b2<\/td><td>15<\/td><td>1396<\/td><td>\u4fdd\u6e29\u677f<\/td><\/tr><tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>93.08<\/td><td>m\u00b2<\/td><td>30<\/td><td>2792<\/td><td>\u84c4\u70ed\u5c42<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6599<\/td><td>\u5361\u9489\u3001\u4f38\u7f29\u7f1d\u7b49<\/td><td>1<\/td><td>\u6279<\/td><td>200<\/td><td>200<\/td><td><\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u5f2f\u7ba1\u5957<\/td><td>\u00d820<\/td><td>14<\/td><td>\u4e2a<\/td><td>2<\/td><td>28<\/td><td>\u4fdd\u62a4\u5730\u6696\u7ba1<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b\u6750\u6599<\/td><td>\/<\/td><td>1<\/td><td>\u5957<\/td><td>180<\/td><td>180<\/td><td>\u68c0\u6d4b\u7cfb\u7edf\u538b\u529b<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6c34\u6ce5\u7802\u6d46<\/td><td>\/<\/td><td>1<\/td><td>\u9879<\/td><td>0<\/td><td>0<\/td><td>\u4e1a\u4e3b\u63d0\u4f9b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5c0f\u8ba1\uff1a9171 \u5143<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> \u5730\u6696\u8bbe\u8ba1\u53c2\u6570<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u697c\u5c42<\/strong><\/td><td><strong>\u623f\u95f4\u529f\u80fd<\/strong><\/td><td><strong>\u9762\u79ef(m\u00b2)<\/strong><\/td><td><strong>\u70ed\u6307\u6807(W\/m\u00b2)<\/strong><\/td><td><strong>\u5236\u70ed\u91cf(W)<\/strong><\/td><td><strong>\u6e29\u63a7\u5668(\u4e2a)<\/strong><\/td><td><strong>\u76d8\u7ba1\u95f4\u8ddd(mm)<\/strong><\/td><td><strong>\u8def\u6570<\/strong><\/td><td><strong>\u5206\u6c34\u7bb1<\/strong><\/td><\/tr><tr><td>\u5e73\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>46.42<\/td><td>100<\/td><td>4642<\/td><td>1<\/td><td>200<\/td><td>3<\/td><td>1<\/td><\/tr><tr><td><\/td><td>\u4e3b\u5367<\/td><td>19.28<\/td><td>100<\/td><td>1928<\/td><td>1<\/td><td>200<\/td><td>1<\/td><td><\/td><\/tr><tr><td><\/td><td>\u6b21\u53671<\/td><td>8.29<\/td><td>100<\/td><td>829<\/td><td>1<\/td><td>200<\/td><td>1<\/td><td><\/td><\/tr><tr><td><\/td><td>\u6b21\u53672<\/td><td>7.39<\/td><td>100<\/td><td>739<\/td><td>1<\/td><td>200<\/td><td>1<\/td><td><\/td><\/tr><tr><td><\/td><td>\u6b21\u53673<\/td><td>11.7<\/td><td>100<\/td><td>1170<\/td><td>1<\/td><td>200<\/td><td>1<\/td><td><\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td><\/td><td><strong>93.08<\/strong><\/td><td><\/td><td><strong>9308<\/strong><\/td><td><strong>5<\/strong><\/td><td><\/td><td><strong>7<\/strong><\/td><td><strong>1<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u98ce\u7cfb\u7edf\uff08<a href=\"https:\/\/longmai-nt.com\/?page_id=1758\">\u65e5\u7acb\u5929\u51c0\u65b0\u98ce<\/a>\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> \u65b0\u98ce\u8bbe\u5907\u53ca\u8f85\u6750<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u54c1\u724c<\/strong><\/td><td><strong>\u540d\u79f0<\/strong><\/td><td><strong>\u89c4\u683c\u578b\u53f7<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><td><strong>\u5355\u4f4d<\/strong><\/td><td><strong>\u529f\u80fd<\/strong><\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u5929\u51c0\u65b0\u98ce<\/td><td>KPI-3521Q5\/F<\/td><td>1<\/td><td>\u53f0<\/td><td>\u53ccDC\u98ce\u673a\/6\u6863\u98ce\u901f\/\u9ad8\u5206\u5b50\u82af\u4f53<\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u4e91\u51c0\u2161\u7ebf\u63a7\u5668<\/td><td>PC-P1K3Q<\/td><td>1<\/td><td>\u4e2a<\/td><td>\u5f69\u5c4fWiFi\u7ebf\u63a7\u5668<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>PE\u6ce2\u7eb9\u7ba1<\/td><td>p110\/p75<\/td><td>1<\/td><td>\u9879<\/td><td>\u73af\u4fdd\u65e0\u83cc\u98ce\u7ba1<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u4e3b\u673a\u8fde\u63a5\u7ba1<\/td><td>p110<\/td><td>1<\/td><td>\u9879<\/td><td>\u5bc6\u5c01\u9632\u5c18\u964d\u566a<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u76f4\u63a5\/\u53d8\u5f84\/\u4e09\u901a<\/td><td>\u9002\u914d<\/td><td>1<\/td><td>\u9879<\/td><td>\u7ba1\u9053\u8fde\u63a5\u4ef6<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>PE\u7ba1\u62b1\u5361<\/td><td>p110\/p75<\/td><td>1<\/td><td>\u9879<\/td><td>\u56fa\u5b9a\u98ce\u7ba1<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3<\/td><td>p75<\/td><td>1<\/td><td>\u9879<\/td><td>ABS\u53ef\u8c03\u8282\u98ce\u53e3<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3\u5957\u4ef6<\/td><td>p75<\/td><td>1<\/td><td>\u9879<\/td><td>ABS\u906e\u853d\u5b54\u6d1e<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u9632\u96e8\u98ce\u7f69<\/td><td>p120<\/td><td>1<\/td><td>\u9879<\/td><td>304\u4e0d\u9508\u94a2\u9632\u96e8\u7f69<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u65b0\u98ce\u5b89\u88c5\u8c03\u8bd5<\/td><td>\u6811\u72b6\u5b89\u88c5<\/td><td>1<\/td><td>\u9879<\/td><td>\u5b89\u88c5\u670d\u52a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u98ce\u91cf\u8bbe\u8ba1<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u623f\u95f4<\/strong><\/td><td><strong>\u9762\u79ef(m\u00b2)<\/strong><\/td><td><strong>\u6362\u6c14\u6b21\u6570<\/strong><\/td><td><strong>\u65b0\u98ce\u91cf(m\u00b3\/h)<\/strong><\/td><td><strong>\u9001\u98ce\u53e3<\/strong><\/td><td><strong>\u6392\u98ce\u53e3<\/strong><\/td><\/tr><tr><td>\u5ba2\u9910\u5385<\/td><td>46.42<\/td><td>0.7<\/td><td>88<\/td><td>2<\/td><td>2<\/td><\/tr><tr><td>\u4e3b\u5367<\/td><td>19.28<\/td><td>0.7<\/td><td>36<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u6b21\u53671<\/td><td>8.29<\/td><td>0.7<\/td><td>16<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u6b21\u53672<\/td><td>7.39<\/td><td>0.7<\/td><td>14<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u6b21\u53673<\/td><td>11.7<\/td><td>0.7<\/td><td>22<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td><strong>93.08<\/strong><\/td><td><\/td><td><strong>176<\/strong><\/td><td><strong>6<\/strong><\/td><td><strong>6<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">1.2\u3001\u8bbe\u8ba1\u4f9d\u636e<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB50736-2012<\/li>\n\n\n\n<li>\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142-2012<\/li>\n\n\n\n<li>\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300bJGJ\/T440-2018<\/li>\n\n\n\n<li><a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/home-environment.html\">\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/home-environment.html#chapter3\">\u597d\u7cfb\u7edf\u56db\u8981\u7d20\uff1a\u70ed\u6e90+\u8f93\u914d+\u672b\u7aef+\u63a7\u5236<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/fluorine.html\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/floor-heating.html\">\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66<\/a><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u7a7a\u8c03\u8bbe\u8ba1\u53c2\u6570<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u590f\u5b63\uff1a24~26\u2103\uff0c\u6e7f\u5ea640%~60%<\/li>\n\n\n\n<li>\u51ac\u5b63\uff1a18~22\u2103<\/li>\n\n\n\n<li>\u51b7\u8d1f\u8377\u53c2\u8003\uff1a\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u5c42\u4f4f\u5b85\uff1a80~120W\/m\u00b2<\/li>\n\n\n\n<li>\u591a\u5c42\u4f4f\u5b85\uff1a88~150W\/m\u00b2<\/li>\n\n\n\n<li>\u522b\u5885\uff1a150~220W\/m\u00b2<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u5730\u6696\u8bbe\u8ba1\u53c2\u6570<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u8bbe\u8ba1\u5ba4\u6e29\uff1a18~22\u2103<\/li>\n\n\n\n<li>\u4f9b\u6c34\u6e29\u5ea6\uff1a35~45\u2103<\/li>\n\n\n\n<li>\u4f9b\u56de\u6c34\u6e29\u5dee\uff1a5~10\u2103<\/li>\n\n\n\n<li>\u76d8\u7ba1\u95f4\u8ddd\uff1a200mm<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u5730\u677f\u6750\u8d28\u5f71\u54cd\uff08\u6563\u70ed\u91cf\u7531\u9ad8\u5230\u4f4e\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u74f7\u7816 &gt; \u590d\u5408\u5730\u677f &gt; \u5f3a\u5316\u6728\u5730\u677f &gt; \u5b9e\u6728\u5730\u677f &gt; \u5730\u6bef<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">1.3\u3001\u5907\u6ce8\u8bf4\u660e<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7a7a\u8c03\u90e8\u5206\u542b\u8bbe\u5907\u3001\u5b89\u88c5\u3001\u98ce\u53e3\u3001\u8f6f\u63a5\u3001\u8f85\u6750\u7b49\uff0c\u5305\u5de5\u5305\u6599\uff1b<\/li>\n\n\n\n<li>\u5730\u6696\u90e8\u5206\u4e0d\u542b\u751f\u6d3b\u70ed\u6c34\u5faa\u73af\u6cf5\uff08\u987e\u5ba2\u81ea\u9009\uff09\uff1b<\/li>\n\n\n\n<li>\u65b0\u98ce\u90e8\u5206\u4e0d\u542b\u7535\u6e90\u7ebf\u3001\u8fdc\u7a0b\u8d39\u3001\u5f00\u7968\u3001\u5f00\u53e3\u57fa\u7840\u8d39\u7528\uff1b<\/li>\n\n\n\n<li>\u5730\u6696\u56de\u586b\u6c34\u6ce5\u7802\u6d46\u7531\u4e1a\u4e3b\u63d0\u4f9b\uff1b<\/li>\n\n\n\n<li>\u6240\u6709\u62a5\u4ef7\u4ec5\u4f9b\u53c2\u8003\uff0c\u6700\u7ec8\u4ee5\u5408\u540c\u7b7e\u5b57\u76d6\u7ae0\u4e3a\u51c6\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 id=\"yjd022\" class=\"wp-block-heading\">2\u3001\u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de56\u6b65\u6cd5+2<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">2.1 \u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">2.2 \u7b2c\u4e8c\u6b65\uff1a\u8bbe\u8ba1\u51fa\u56fe\uff08\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u5e03\u7f6e\u3001\u5730\u6696\u7cfb\u7edf\u53ca\u76d8\u7ba1\u56fe\u7eb8\u3001\u65b0\u98ce\u5e03\u7ba1\uff09<\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u8bbe\u8ba1\u56fe01-768x1024.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u8bbe\u8ba1\u00b7\u5730\u6696\u76d8\u7ba1\u548c\u7cfb\u7edf\u8bbe\u8ba1\u56fe\u7eb8\" class=\"wp-image-1009\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u8bbe\u8ba1\u56fe01-768x1024.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u8bbe\u8ba1\u56fe01-225x300.jpeg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u8bbe\u8ba1\u56fe01-1152x1536.jpeg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u5730\u6696\u8bbe\u8ba1\u56fe01.jpeg 1170w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u8bbe\u8ba1\u56fe01-768x1024.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u8bbe\u8ba1\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u8bbe\u8ba1\u56fe\u7eb8\" class=\"wp-image-1010\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u8bbe\u8ba1\u56fe01-768x1024.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u8bbe\u8ba1\u56fe01-225x300.jpeg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u8bbe\u8ba1\u56fe01-1152x1536.jpeg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u8bbe\u8ba1\u56fe01.jpeg 1170w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"988\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u8bbe\u8ba1\u56fe01-1024x988.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65b9\u6848\u8bbe\u8ba1\u00b7\u65e5\u7acb\u65b0\u98ce\u5e03\u7f6e\u8bbe\u8ba1\u56fe\u7eb8\" class=\"wp-image-1011\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u8bbe\u8ba1\u56fe01-1024x988.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u8bbe\u8ba1\u56fe01-300x290.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u8bbe\u8ba1\u56fe01-768x741.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u8bbe\u8ba1\u56fe01.jpeg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h4 id=\"yjd0223\" class=\"wp-block-heading\">2.3 \u7b2c\u4e09\u6b65\uff1a\u9690\u853d\u5de5\u7a0b\u7cbe\u5de56\u6b65\u6cd5\uff08\u5b9a\u4f4d+\u6e05\u5355\u9a8c\u6536+\u6309\u56fe\u65bd\u5de5+\u6807\u51c6\u5de5\u827a+\u76d1\u7406+\u4e09\u65b9\u9a8c\u6536\uff09<\/h4>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">\u6309\u56fe\u65bd\u5de5\u3001\u9690\u853d\u5de5\u7a0b\u5e03\u7ba1\u3001\u51b7\u51dd\u6c34\u6392\u6c34\u6392\u6c14\u3001\u6807\u51c6\u5de5\u827a\u6c2e\u6c14\u4fdd\u62a4\u710a<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u7ba1\u8def\u56fe03-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u51b7\u51dd\u6c34\u6392\u6c14\u9600\" class=\"wp-image-1001\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u7ba1\u8def\u56fe03-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u7ba1\u8def\u56fe03-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u7ba1\u8def\u56fe03-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u7ba1\u8def\u56fe03-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u7ba1\u8def\u56fe03.jpeg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u56fe01-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u5185\u673a\u540a\u88c5\" class=\"wp-image-1002\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u56fe01-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u56fe01-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u56fe01-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u56fe01-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u56fe01.jpeg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe01-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u5185\u673a\u540a\u88c5\u548c\u5e03\u7ba1\" class=\"wp-image-1003\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe01-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe01-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe01-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe01-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe01-2048x1536.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5185\u673a\u7ba1\u9053\u5c01\u88c5\u3001\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u98ce\u901f\u6d4b\u8bd5<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe02-768x1024.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u5185\u673a\u540a\u88c5\u548c\u65b0\u98ce\u5e03\u7ba1\" class=\"wp-image-1004\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe02-768x1024.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe02-225x300.jpeg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe02-1152x1536.jpeg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u65b0\u98ce\u5b89\u88c5\u56fe02.jpeg 1440w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe01-768x1024.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u65b0\u98ce\u98ce\u53e3\u98ce\u901f\u6d4b\u8bd51\" class=\"wp-image-1005\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe01-768x1024.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe01-225x300.jpeg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe01-1152x1536.jpeg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe01.jpeg 1280w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe02-768x1024.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u65b0\u98ce\u98ce\u53e3\u98ce\u901f\u6d4b\u8bd52\" class=\"wp-image-1006\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe02-768x1024.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe02-225x300.jpeg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe02-1152x1536.jpeg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u68c0\u6d4b\u56fe02.jpeg 1280w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5916\u673a\u4e3b\u7ba1\u8d70\u7ba1\u3001\u4fdd\u6e29\u68c0\u67e5\u3001\u6c2e\u6c14\u4fdd\u538b<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u56fe01-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e3b\u673a\u5b89\u88c5\u548c\u4fdd\u538b\" class=\"wp-image-1007\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u56fe01-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u56fe01-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u56fe01-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u56fe01-1536x1152.jpeg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u7a7a\u8c03\u5916\u673a\u56fe01.jpeg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u7a7a\u8c03\u8d70\u7ba1\u56fe02-1024x768.jpeg\" alt=\"\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u65bd\u5de5\u7167\u7247\u00b7\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e3b\u7ba1\u548c\u65b0\u98ce\u4e3b\u7ba1\u8d70\u7ba1\" class=\"wp-image-1008\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u7a7a\u8c03\u8d70\u7ba1\u56fe02-1024x768.jpeg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u7a7a\u8c03\u8d70\u7ba1\u56fe02-300x225.jpeg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u7a7a\u8c03\u8d70\u7ba1\u56fe02-768x576.jpeg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u65b0\u98ce\u7a7a\u8c03\u8d70\u7ba1\u56fe02.jpeg 1440w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">2.4 \u7b2c\u56db\u6b65\uff1a\u76d1\u7406\u5230\u4f4d<\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">2.5 \u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">2.6 \u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536\uff08\u542b\u8c03\u8bd5\u9a8c\u6536\u5355\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u9a8c\u6536\u65e5\u671f<\/td><td>  \u5e74 \u6708 \u65e5<\/td><\/tr><tr><td>\u9a8c\u6536\u4eba\u5458<\/td><td><\/td><\/tr><tr><td>\u9a8c\u6536\u5185\u5bb9<\/td><td>\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c\/\u7a7a\u8c03\u9001\u98ce\u53e3\u5b9e\u6d4b\/\u5404\u623f\u95f4\u6548\u679c\u786e\u8ba4\/APP\u8fdc\u7a0b\u63a7\u5236\u6f14\u793a<\/td><\/tr><tr><td>\u9a8c\u6536\u7ed3\u8bba<\/td><td><\/td><\/tr><tr><td><strong>\u9a8c\u6536\u7167\u7247<\/strong><\/td><td><em>\u89c1\u4e0b\u65b9<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">2.7 +1\uff1a\u4ea4\u4ed8\u6559\u5b66\uff08\u542b\u64cd\u4f5c\u8981\u70b9\u901f\u67e5\uff09<\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u00b7\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u7cfb\u7edf\u64cd\u4f5c\u901f\u67e5\u8868<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e00\u3001\u4e2d\u592e\u7a7a\u8c03\u90e8\u5206\uff08\u65e5\u7acb\uff09<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u8981\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5b9a\/\u64cd\u4f5c\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td>\u5236\u51b7\u6a21\u5f0f\u8bbe\u5b9a<\/td><td>\u590f\u5b63\u8bbe\u5b9a\u6e29\u5ea6&nbsp;<strong>24-26\u2103<\/strong>\uff0c\u6e7f\u5ea6&nbsp;<strong>40%-60%<\/strong><\/td><\/tr><tr><td>\u5236\u70ed\u6a21\u5f0f\u8bbe\u5b9a<\/td><td>\u51ac\u5b63\u8bbe\u5b9a\u6e29\u5ea6&nbsp;<strong>18-22\u2103<\/strong><\/td><\/tr><tr><td>\u98ce\u901f\u5efa\u8bae<\/td><td>\u81ea\u52a8\u98ce\u901f\u4f18\u5148\uff1b\u9759\u97f3\u9700\u6c42\u53ef\u624b\u52a8\u8c03\u81f3\u4f4e\u98ce<\/td><\/tr><tr><td>\u6ee4\u7f51\u6e05\u6d17<\/td><td><strong>\u6bcf\u6708\u6e05\u6d17\u4e00\u6b21<\/strong>\uff08\u56de\u98ce\u53e3\u6ee4\u7f51\uff0c\u6e05\u6c34\u51b2\u6d17\u667e\u5e72\u540e\u88c5\u56de\uff09<\/td><\/tr><tr><td>\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><td><strong>\u6362\u5b63\u65f6\u8fd0\u884c\u4e00\u6b21<\/strong>\uff08\u7ea630\u5206\u949f\uff09\uff0c\u957f\u6309\u201c\u81ea\u6e05\u6d01\u201d\u952e\u542f\u52a8<\/td><\/tr><tr><td>\u5916\u673a\u6563\u70ed<\/td><td>\u786e\u4fdd\u5916\u673a\u5468\u56f4\u65e0\u6742\u7269\u5806\u653e\uff0c\u901a\u98ce\u826f\u597d<\/td><\/tr><tr><td>\u957f\u65f6\u95f4\u4e0d\u7528<\/td><td>\u65ad\u7535\uff0c\u6e05\u6d17\u6ee4\u7f51\u540e\u5173\u673a<\/td><\/tr><tr><td>\u7ebf\u63a7\u5668\u64cd\u4f5c<\/td><td>\u9ad8\u6e05\u5f69\u5c4f\u89e6\u6478\u64cd\u4f5c\uff0c\u53ef\u8bbe\u7f6e\u6bcf\u5468\u5b9a\u65f6\u5f00\u5173\u673a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e8c\u3001\u5730\u6696\u90e8\u5206\uff08\u745e\u7f8e\u71c3\u6c14\u58c1\u6302\u7089\uff09<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u8981\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5b9a\/\u64cd\u4f5c\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td><strong>\u9505\u7089\u6c34\u6e29\u8bbe\u7f6e<\/strong><\/td><td><strong>35-45\u2103<\/strong>\uff08\u5730\u6696\u4f4e\u6e29\u8fd0\u884c\uff0c\u4e0d\u8d85\u8fc750\u2103\uff09<\/td><\/tr><tr><td>\u5ba4\u6e29\u8bbe\u7f6e<\/td><td>\u5efa\u8bae&nbsp;<strong>18-22\u2103<\/strong>\uff0c\u6bcf\u964d\u4f4e1\u2103\u7701\u6c145-10%<\/td><\/tr><tr><td>\u9996\u6b21\u5347\u6e29<\/td><td>\u5206\u6b65\u5347\u6e29\uff0c\u6bcf\u5929\u22645\u2103\uff0c\u907f\u514d\u5730\u9762\u5f00\u88c2<\/td><\/tr><tr><td>\u5916\u51fa\u6a21\u5f0f<\/td><td>\u77ed\u671f\u79bb\u5bb6\u8c03\u4f4e\u5ba4\u6e29\u81f3&nbsp;<strong>14-16\u2103<\/strong>\uff0c<strong>\u4e0d\u8981\u5b8c\u5168\u5173\u95ed<\/strong><\/td><\/tr><tr><td>\u957f\u671f\u79bb\u5bb6<\/td><td>\u4fdd\u6301\u9505\u7089\u901a\u7535\u901a\u6c14\uff0c\u542f\u7528\u9632\u51bb\u6a21\u5f0f<\/td><\/tr><tr><td>\u7cfb\u7edf\u8865\u6c34<\/td><td>\u6c34\u538b\u4f4e\u4e8e<strong>1.0bar<\/strong>\u65f6\u6253\u5f00\u8865\u6c34\u9600\uff0c\u8865\u6c34\u81f3<strong>1.2-1.5bar<\/strong>\u540e\u5173\u95ed<\/td><\/tr><tr><td>\u6392\u6c14\u64cd\u4f5c<\/td><td>\u91c7\u6696\u5b63\u5f00\u59cb\u524d\uff0c\u5bf9\u5206\u96c6\u6c34\u5668\u8fdb\u884c\u6392\u6c14<\/td><\/tr><tr><td>\u5ba4\u6e29\u8054\u52a8<\/td><td>\u6e29\u63a7\u5668\u8bbe\u5b9a\u6e29\u5ea6\u540e\uff0c\u9505\u7089\u81ea\u52a8\u542f\u505c\uff08\u5df2\u914d\u65e0\u7ebf\u8054\u52a8\uff09<\/td><\/tr><tr><td>\u6ee4\u7f51\u6e05\u6d17<\/td><td>\u6bcf\u5e74\u6e05\u6d17\u56de\u6c34\u8fc7\u6ee4\u5668<\/td><\/tr><tr><td>\u6c34\u8d28\u68c0\u67e5<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\uff0c\u653e\u6c34\u89c2\u5bdf\u989c\u8272\uff0c\u5224\u65ad\u8150\u8680\u7a0b\u5ea6<\/td><\/tr><tr><td>\u9505\u7089\u4fdd\u517b<\/td><td>1-2\u5e74\u6e05\u6d17\u71c3\u70e7\u5ba4\u3001\u98ce\u673a\u53f6\u8f6e\u3001\u6587\u4e18\u91cc\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e09\u3001\u65b0\u98ce\u7cfb\u7edf\uff08\u65e5\u7acb\u5929\u51c0\u65b0\u98ce\uff0c\u67e5\u770b\u65e5\u7acb\u65b0\u98ce\u5b8c\u6574\u4ecb\u7ecd<a href=\"https:\/\/longmai-nt.com\/?page_id=1758\">\u70b9\u51fb\u8fd9\u91cc\u2192<\/a>\uff09<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u8981\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5b9a\/\u64cd\u4f5c\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td>\u8fd0\u884c\u6a21\u5f0f<\/td><td>\u6362\u6c14\u6a21\u5f0f\u4e0b<strong>\u8282\u80fd\u65b0\u98ce\u4f18\u5148<\/strong>\uff08\u5168\u70ed\u4ea4\u6362\u56de\u653670%\u80fd\u91cf\uff09<\/td><\/tr><tr><td>\u65b0\u98ce\u91cf\u6863\u4f4d<\/td><td>\u65e5\u5e38\u4f4e\u6863\u7ef4\u6301\uff1bCO\u2082\u5347\u9ad8\u81ea\u52a8\u52a0\u5927\u65b0\u98ce\u91cf<\/td><\/tr><tr><td>\u6ee4\u7f51\u66f4\u6362<\/td><td><strong>3-6\u4e2a\u6708\u66f4\u6362\u4e00\u6b21<\/strong>\uff08HEPA\u6ee4\u7f51\/\u6d3b\u6027\u70ad\u6ee4\u7f51\uff09<\/td><\/tr><tr><td>\u4e94\u7ef4\u76d1\u6d4b<\/td><td>\u5efa\u8bae24h\u5f00\u542f\u5185\u5faa\u73af\u6a21\u5f0f\uff0c\u5b9e\u65f6\u67e5\u770b\u6e29\/\u6e7f\/PM2.5\/CO\u2082\/TVOC\u6570\u636e<\/td><\/tr><tr><td>\u5ba4\u5916\u96fe\u973e\u5929<\/td><td>\u81ea\u52a8\u5207\u6362\u201c\u5faa\u73af\u51c0\u5316\u201d\u6a21\u5f0f\uff08\u5185\u5faa\u73af\u8fc7\u6ee4\uff09<\/td><\/tr><tr><td>\u957f\u671f\u79bb\u5bb6<\/td><td>\u53ef\u5173\u95ed\u65b0\u98ce\uff0c\u6216\u4fdd\u7559\u6700\u4f4e\u6863\u7ef4\u6301\u57fa\u7840\u6362\u6c14<\/td><\/tr><tr><td>\u7ebf\u63a7\u5668\u64cd\u4f5c<\/td><td>\u5f69\u5c4fWiFi\u7ebf\u63a7\u5668\uff0c\u53ef\u8bbe\u7f6e\u5b9a\u65f6\/\u67e5\u770b\u6ee4\u7f51\u5bff\u547d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u56db\u3001\u901a\u7528\u7ef4\u62a4\u63d0\u9192<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5468\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u5185\u673a\u6ee4\u7f51\u6e05\u6d17<\/td><td>\u6bcf\u6708<\/td><td>\u81ea\u884c\u64cd\u4f5c\uff0c\u6e05\u6c34\u51b2\u6d17<\/td><\/tr><tr><td>\u65b0\u98ce\u6ee4\u7f51\u66f4\u6362<\/td><td>\u9884\u8ba13-6\u4e2a\u6708\uff0cpm2.5\u4f20\u611f\u5668\u81ea\u52a8\u62a5\u8b66<\/td><td>\u8054\u7cfb\u552e\u540e\u6216\u81ea\u884c\u8d2d\u4e70\u66f4\u6362<\/td><\/tr><tr><td>\u9505\u7089\u4fdd\u517b<\/td><td>1-2\u5e74<\/td><td>\u4e13\u4e1a\u552e\u540e\u4e0a\u95e8<\/td><\/tr><tr><td>\u5730\u6696\u76d8\u7ba1\u6e05\u6d17<\/td><td>2-4\u5e74<\/td><td>\u4e13\u4e1a\u552e\u540e\u4e0a\u95e8<\/td><\/tr><tr><td>\u7cfb\u7edf\u5e74\u5ea6\u68c0\u6d4b<\/td><td>\u6bcf\u5e74<\/td><td>\u4f1a\u5458\u670d\u52a1\u5305\u542b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u4e94\u3001\u7d27\u6025\u60c5\u51b5\u5904\u7406<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5904\u7406\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td>\u9505\u7089\u62a5E10\uff08\u7f3a\u6c34\uff09<\/td><td>\u6253\u5f00\u8865\u6c34\u9600\uff0c\u8865\u6c34\u81f31.2-1.5bar<\/td><\/tr><tr><td>\u9505\u7089\u62a5E03\uff08\u98ce\u538b\u6545\u969c\uff09<\/td><td>\u8054\u7cfb\u552e\u540e\uff08\u53ef\u80fd\u662f\u6587\u4e18\u91cc\u7ba1\u5835\u585e\uff09<\/td><\/tr><tr><td>\u5730\u6696\u4e0d\u70ed<\/td><td>\u68c0\u67e5\u5206\u96c6\u6c34\u5668\u9600\u95e8\u662f\u5426\u6253\u5f00\uff1b\u6392\u6c14\uff1b\u8054\u7cfb\u552e\u540e<\/td><\/tr><tr><td>\u65b0\u98ce\u65e0\u53cd\u5e94<\/td><td>\u68c0\u67e5\u7535\u6e90\uff1b\u68c0\u67e5\u7ebf\u63a7\u5668\u662f\u5426\u6b63\u5e38\uff1b\u8054\u7cfb\u552e\u540e<\/td><\/tr><tr><td>\u7a7a\u8c03\u4e0d\u5236\u51b7\/\u70ed<\/td><td>\u68c0\u67e5\u6ee4\u7f51\u662f\u5426\u5835\u585e\uff1b\u68c0\u67e5\u5916\u673a\u662f\u5426\u901a\u98ce\uff1b\u8054\u7cfb\u552e\u540e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">2.8 +2\uff1a\u552e\u540e\u4fdd\u969c\uff08\u542b\u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u969c\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u8bbe\u5907\u8d28\u4fdd<\/td><td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd<\/td><\/tr><tr><td>\u5de5\u7a0b\u8d28\u4fdd<\/td><td>5\u5e74\u8d77<\/td><\/tr><tr><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td><\/tr><tr><td>\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b\/\u7ef4\u4fdd\u63d0\u9192\/\u4f18\u5148\u54cd\u5e94\/\u670d\u52a1\u6298\u6263\/\u8fdc\u7a0b\u8bca\u65ad<\/td><\/tr><tr><td>\u7d27\u6025\u62a5\u4fee<\/td><td><em><a href=\"tel:4008601111\">\u65e5\u7acb\u5b98\u65b9400\u7535\u8bdd<\/a><\/em> <a href=\"tel:13183879308\">\u9f99\u8109\u6696\u901a\u552e\u540e\u7535\u8bdd<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"yjd03\" class=\"wp-block-heading\">\u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3<\/h2>\n\n\n\n<h3 id=\"yjd031\" class=\"wp-block-heading\">1\u3001\u5ba2\u6237\u53cd\u9988\uff082026.2.25\u53f7\u5c0f\u7ea2\u4e66\u7b14\u8bb0\u53cd\u9988\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03+\u65b0\u98ce\u7cfb\u7edf\u5b89\u88c5\u597d\u8bc4<br>\u88c5\u4fee\u9009\u6696\u901a\u8bbe\u5907\u505a\u4e86\u8d85\u591a\u529f\u8bfe\uff0c\u6700\u7ec8\u6572\u5b9a\u9f99\u8109\u7684\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03+\u65e5\u7acb\u65b0\u98ce\u7cfb\u7edf+\u5730\u6696\u7cfb\u7edf\uff0c\u4ece\u4ea7\u54c1\u5230\u5b89\u88c5\u5168\u7a0b\u8d85\u51fa\u9884\u671f\uff0c\u5fc5\u987b\u5b9e\u540d\u597d\u8bc4!\u524d\u671f\u5927\u534a\u5e74\u7684\u65f6\u95f4\u505a\u653b\u7565\uff0c\u4e86\u89e3\u54c1\u724c\u548c\u670d\u52a1\u5546\u7684\u91cd\u8981\u6027\uff0c\u53e6\u5916\u524d\u671f\u505a\u8bbe\u8ba1\u548c\u9500\u552e\u4e5f\u7279\u522b\u91cd\u8981\u3002\u9f99\u8109\u6696\u901a\u7684\u8303\u8001\u5e08\u8fd8\u6709\u7f2a\u8001\u5e08\u975e\u5e38\u7684\u4e13\u4e1a\uff0c\u6df1\u5165\u4e86\u89e3\u6211\u7684\u9700\u6c42\uff0c\u7ed9\u6211\u3002\u5236\u5b9a\u4e86\u9488\u5bf9\u6027\u7684\u89e3\u51b3\u65b9\u6848\u3002\u7136\u540e\u65b9\u6848\u63a5\u8fd1\u4e00\u4e2a\u6708\u53cd\u590d\u4fee\u6539\uff0c\u624d\u6709\u76ee\u524d\u7684\u5b8c\u7f8e\u5b9e\u65bd\uff0c\u671f\u5f85\u6700\u7ec8\u6548\u679c\u5448\u73b0\u3002\u6700\u8981\u5938\u7684\u662f\u5b89\u88c5\u670d\u52a1\u5e08\u5085\u56e2\u961f\u4e13\u4e1a\u53c8\u8d1f\u8d23\uff0c\u63d0\u524d\u6c9f\u901a\u3002\u4e0a\u95e8\u65f6\u95f4\uff0c\u65bd\u5de5\u89c4\u8303\u3001\u8d70\u7ebf\u6574\u9f50\u3001\u5de5\u827a\u7ec6\u81f4\uff0c\u4e25\u683c\u6309\u7167\u6807\u51c6\u6d41\u7a0b\u64cd\u4f5c\uff0c\u6bcf\u4e2a\u8282\u70b9\u90fd\u8010\u5fc3\u4ea4\u4ee3\u3002\u5b89\u88c5\u540e\u8ba4\u771f\u8c03\u8bd5\uff0c\u73b0\u573a\u6e05\u7406\u5e72\u51c0\uff0c\u5168\u7a0b\u7701\u5fc3\u653e\u5fc3\uff0c\u771f\u6b63\u505a\u5230\"\u4e09\u5206\u4ea7\u54c1\u3001\u4e03\u5206\u5b89\u88c5\u201d\u7684\u9ad8\u54c1\u8d28\u843d\u5730\u3002\u6700\u7ec8\u603b\u7ed3\u4ea7\u54c1\u91cd\u8981\u3001\u5b89\u88c5\u6700\u91cd\u8981\uff0c\u61c2\u4ea7\u54c1\u7684\u4eba\u66f4\u91cd\u8981\uff01\u5bb6\u88c5\u6696\u901a\u95ed\u773c\u9009\u9f99\u8109\u6696\u901a\u4e0d\u8e29\u5751\uff0c\u5b89\u88c5\u552e\u540e\u4e5f\u9760\u8c31\u5230\u4f4d\uff0c\u54c1\u8d28\u4e0e\u670d\u52a1\u53cc\u5728\u7ebf\uff0c\u5f3a\u70c8\u63a8\u8350\uff01<\/p>\n\n\n\n<h3 id=\"yjd032\" class=\"wp-block-heading\">2\u3001\u80fd\u8017\u8ddf\u8e2a\u4e0e\u89e3\u6790 \u5f85\u5e74\u5ea6\u6570\u636e\u5f55\u5165\u3002<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u00b7\u5730\u6696\u80fd\u8017\u8ddf\u8e2a\u6863\u6848<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">2.1\u3001<strong>\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u5173\u6ce8\u60a8\u672a\u676520\u5e74\u7684\u4f7f\u7528\u8212\u9002\u3001\u7a33\u5b9a\u548c\u8282\u80fd\u3002\u4e3a\u6b64\uff0c\u6211\u4eec\u627f\u8bfa\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1\u3001\u6bcf\u5e74\u80fd\u8017\u5206\u6790\u4e0e\u4f18\u5316\u5efa\u8bae<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\uff0c\u4e3a\u60a8\u63d0\u4f9b\u4e00\u4efd\u80fd\u8017\u5206\u6790\u62a5\u544a\uff0c\u5305\u542b\uff1a\u5f53\u5e74\u5b9e\u9645\u7528\u6c14\u91cf\u53ca\u8d39\u7528\u3001\u540c\u6237\u578b\u540c\u914d\u7f6e\u5bf9\u6807\u6570\u636e\u3001\u8282\u80fd\u4f18\u5316\u5efa\u8bae\u3002\u5982\u7cfb\u7edf\u8fd0\u884c\u8d39\u7528\u663e\u8457\u9ad8\u4e8e\u5408\u7406\u8303\u56f4\uff0c\u6211\u4eec\u4e3b\u52a8\u4e0a\u95e8\u6392\u67e5\u539f\u56e0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2\u3001\u514d\u8d39\u4f18\u5316\u65b9\u6848<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u6392\u67e5\u53d1\u73b0\u7cfb\u7edf\u5b58\u5728\u53ef\u4f18\u5316\u7684\u73af\u8282\uff08\u5982\u7ba1\u8def\u6c34\u529b\u5e73\u8861\u5fae\u8c03\u3001\u6e29\u63a7\u903b\u8f91\u5347\u7ea7\u3001\u8bbe\u5907\u53c2\u6570\u8c03\u6574\uff09\uff0c\u6211\u4eec\u514d\u8d39\u63d0\u4f9b\u4f18\u5316\u65b9\u6848\u5e76\u534f\u52a9\u5b9e\u65bd\u3002\u5982\u5f02\u5e38\u539f\u56e0\u4e3a\u7cfb\u7edf\u8bbe\u8ba1\u6216\u65bd\u5de5\u7f3a\u9677\uff0c\u6211\u4eec\u514d\u8d39\u63d0\u4f9b\u7cfb\u7edf\u4f18\u5316\u6539\u9020\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">**\u4e0b\u5217\u60c5\u51b5\u4e0d\u5c5e\u4e8e\u7cfb\u7edf\u539f\u56e0\uff0c\u6211\u4eec\u4ecd\u63d0\u4f9b\u514d\u8d39\u7684\u8ddf\u8e2a\u5206\u6790\u62a5\u544a\u548c\u8282\u80fd\u5efa\u8bae\u65b9\u6848\uff0c\u4f46\u4e0d\u627f\u62c5\u6539\u9020\u8d39\u7528\uff1a\u91c7\u6696\u5b63\u957f\u65f6\u95f4\u5f00\u7a97\u901a\u98ce\u3001\u5ba4\u5185\u6e29\u63a7\u5668\u6301\u7eed\u8bbe\u5b9a\u9ad8\u4e8e22\u2103\uff08\u8d85\u51fa\u8bbe\u8ba1\u57fa\u51c620\u2103\u00b12\u2103\uff09\u3001\u672a\u6309\u4ea4\u4ed8\u6559\u5b66\u8981\u6c42\u8fdb\u884c\u8865\u6c34\/\u6392\u6c14\/\u58c1\u6302\u7089\u53ca\u7cfb\u7edf\u6df1\u5ea6\u6e05\u6d17\u7b49\u57fa\u7840\u7ef4\u62a4\u3001\u623f\u5c4b\u4fdd\u6e29\u6761\u4ef6\u6539\u53d8\uff08\u5982\u62c6\u6539\u95e8\u7a97\u3001\u7834\u574f\u4fdd\u6e29\u5c42\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3\u300110\u5e74\u8ddf\u8e2a\u627f\u8bfa<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u672c\u6863\u6848\u7b7e\u7f72\u65e5\u671f\u4e3a\u8d77\u70b9\uff0c\u6211\u4eec\u63d0\u4f9b<strong>10\u5e74\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1<\/strong>\u3002\u5730\u6696\u76d8\u7ba1\u7531\u4f1f\u661f\u5382\u5bb6\u8d28\u4fdd50\u5e74\uff0c\u5206\u96c6\u6c34\u5668\u8bbe\u8ba1\u5bff\u547d20\u5e74\u4ee5\u4e0a\uff0c\u4e3b\u7ba1\u9053\u5bff\u547d50\u5e74\u4ee5\u4e0a\u3002\u9505\u7089\u4e3a\u56fd\u5bb6\u5f3a\u5236\u62a5\u5e9f\u8bbe\u5907\uff08\u62a5\u5e9f\u671f8\u5e74\uff09\uff0c\u6211\u4eec\u5c06\u5728\u7b2c9\u5e74\u4e3b\u52a8\u63d0\u9192\u60a8\u66f4\u6362\u8bbe\u5907\uff0c\u66f4\u6362\u540e\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u81ea\u52a8\u5ef6\u7eed\uff0c\u8ddf\u8e2a\u5468\u671f\u91cd\u65b0\u8ba1\u7b97\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4\u300120\u5e74\u670d\u52a1\u4fdd\u969c<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10\u5e74\u8ddf\u8e2a\u671f\u6ee1\u540e\uff0c\u6211\u4eec\u7ee7\u7eed\u63d0\u4f9b<strong>\u6301\u7eed\u81f320\u5e74\u7684\u552e\u540e\u7ef4\u4fdd\u670d\u52a1<\/strong>\uff0c\u5305\u62ec\u5e74\u5ea6\u7cfb\u7edf\u68c0\u6d4b\u3001\u7ef4\u4fdd\u63d0\u9192\u3001\u6545\u969c\u6392\u67e5\u3001\u4f18\u5148\u54cd\u5e94\u3002\u670d\u52a1\u5185\u5bb9\u4e0d\u53d8\uff0c\u670d\u52a1\u6807\u51c6\u4e0d\u964d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u6761\u627f\u8bfa\u81ea\u5408\u540c\u7b7e\u7f72\u4e4b\u65e5\u8d77\u4e0e\u6863\u6848\u540c\u6b65\u751f\u6548\u3002<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u7ba1\u8001\u5e08\uff0c\u60a8\u5df2\u52a0\u5165\u9f99\u8109\u6696\u901a\u201c\u5730\u6696\u6d4b\u8bc4\u5b98\u201d\u8ba1\u5212\u3002\u6211\u4eec\u5c06\u5bf9\u60a8\u5bb6\u5730\u6696\u7cfb\u7edf\u8fdb\u884c10\u5e74\u80fd\u8017\u8ddf\u8e2a\uff0c\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\u51fa\u5177\u4e00\u4efd\u80fd\u8017\u5206\u6790\u62a5\u544a\u3002\u8fd9\u4efd\u6863\u6848\u662f\u8ddf\u8e2a\u7684\u6570\u636e\u57fa\u51c6\u3002<\/p>\n<\/blockquote>\n\n\n\n<h5 class=\"wp-block-heading\">2.2\u3001\u6570\u636e\u57fa\u51c6\uff08\u8c03\u8bd5\u5f53\u65e5\u8bb0\u5f55\uff09\uff1a<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u57fa\u51c6\u6570\u636e<\/th><\/tr><\/thead><tbody><tr><td>\u8c03\u8bd5\u65e5\u671f<\/td><td>\u5e74 \u6708 \u65e5<\/td><\/tr><tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>__45_\u2103<\/td><\/tr><tr><td>\u56de\u6c34\u6e29\u5ea6<\/td><td>___\u2103<\/td><\/tr><tr><td>\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6<\/td><td>__20_\u2103<\/td><\/tr><tr><td>\u5ba4\u5916\u6e29\u5ea6<\/td><td>___\u2103<\/td><\/tr><tr><td>\u71c3\u6c14\u8868\u521d\u59cb\u8bfb\u6570<\/td><td>___m\u00b3<\/td><\/tr><tr><td>\u9505\u7089\u578b\u53f7<\/td><td>\u745e\u7f8e LL1GBQ19-CBX1-24<\/td><\/tr><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>93\u33a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u5b63(\u6708)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u603b\u7528\u6c14\u91cf(m\u00b3)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u603b\u8d39\u7528(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6708\u5747\u8d39\u7528(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4f4d\u8d39\u7528(\u5143\/\u33a1\u00b7\u6708)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e1a\u4e3b\u53cd\u9988<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c1\u5e74<\/td><td>2026\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c2\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c3\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c4\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c5\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c6\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c7\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c8\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c9\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c10\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\"><strong>\u80fd\u8017\u5bf9\u6807\u57fa\u51c6<\/strong>\uff08\u4f9bAI\u9a8c\u8bc1\u53ca\u5ba2\u6237\u53c2\u8003\uff09\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u540c\u6237\u578b93\u33a1 \u00b7 \u51b7\u51dd\u7089\u5730\u6696 \u00b7 \u5ba4\u6e2920\u2103 \u00b7 \u6210\u90fd\u5730\u533a<\/li>\n\n\n\n<li>\u53c2\u8003\u5b63\u8d39\u7528\uff1a<strong>\u7ea63,500\u5143\/\u5b63<\/strong>\uff08\u7406\u8bba\u8ba1\u7b97\u503c\uff0c\u57fa\u4e8eGB 50736-2012 50W\/m\u00b2\u80fd\u8017\u8d1f\u8377\uff09<\/li>\n\n\n\n<li>\u8ba1\u7b97\u516c\u5f0f\uff1a93\u33a1 \u00d7 50W\/m\u00b2 \u00d7 24h \u00d7 120\u5929 \u00f7 10 \u00f7 95% \u00d7 2.5\u5143\/\u65b9 = 3,522.5\u5143<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7cfb\u7edf\u6761\u4ef6<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u91c7\u6696\u9762\u79ef\uff1a93\u33a1<\/li>\n\n\n\n<li>\u70ed\u6e90\u7c7b\u578b\uff1a\u51b7\u51dd\u7089\uff08\u5168\u9884\u6df7\u71c3\u70e7\uff09<\/li>\n\n\n\n<li>\u70ed\u6548\u7387\uff1a95%\uff08\u6309\u4f4e\u4f4d\u70ed\u503c\uff09<\/li>\n\n\n\n<li>\u4f9b\u6c34\u6e29\u5ea6\uff1a\u226450\u2103\uff08\u51b7\u51dd\u5de5\u51b5\uff09<\/li>\n\n\n\n<li>\u672b\u7aef\u5f62\u5f0f\uff1a\u5730\u6696\uff08\u8f90\u5c04\u4f9b\u6696\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f7f\u7528\u6761\u4ef6<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5ba4\u6e29\u8bbe\u5b9a\uff1a20\u2103 \u00b1 1\u2103\uff08GB 50736-2012 \u8bbe\u8ba1\u57fa\u51c6\uff09<\/li>\n\n\n\n<li>\u8fd0\u884c\u65f6\u957f\uff1a24\u5c0f\u65f6\/\u5929 \u00d7 120\u5929\/\u91c7\u6696\u5b63<\/li>\n\n\n\n<li>\u65e5\u5747\u70ed\u8d1f\u8377\uff1a50 W\/m\u00b2\uff08GB 50736-2012 \u80fd\u8017\u8d1f\u8377\u6807\u51c6\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5efa\u7b51\u6761\u4ef6<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u8282\u80fd\u5efa\u7b51\uff08\u56f4\u62a4\u7ed3\u6784\u4f20\u70ed\u7cfb\u6570\u7b26\u5408GB 50189-2015\uff09<\/li>\n\n\n\n<li>\u4e0d\u5f00\u7a97\u901a\u98ce\uff08\u65b0\u98ce\u7cfb\u7edf\u6216\u5b9a\u65f6\u6362\u6c14\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8d39\u7528\u6761\u4ef6<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6c14\u4ef7\uff1a2.5\u5143\/\u65b9\uff08\u6210\u90fd\u5c45\u6c11\u7528\u6c14\u7b2c\u4e8c\u9636\u68af\uff09<\/li>\n\n\n\n<li>\u5929\u7136\u6c14\u70ed\u503c\uff1a1\u65b9\u6c14 = 10 kWh\uff08\u7406\u8bba\u9ad8\u70ed\u503c\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7406\u8bba\u8ba1\u7b97\u503c<\/strong>\uff1a\u7ea6 3,520 \u5143\/\u5b63<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u504f\u5dee\u8bf4\u660e<\/strong>\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u56e0\u7d20\u4f1a\u5bfc\u81f4\u5b9e\u9645\u8d39\u7528\u9ad8\u4e8e\u53c2\u8003\u503c\uff08\u504f\u5dee\u8303\u56f4\uff1a+20%~+50%\uff09\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5ba4\u6e29\u8bbe\u5b9a\u6bcf\u63d0\u9ad81\u2103 \u2192 \u80fd\u8017\u589e\u52a0\u7ea65-10%<\/li>\n\n\n\n<li>\u4f9b\u6c34\u6e29\u5ea6\u9ad8\u4e8e55\u2103 \u2192 \u51b7\u51dd\u7089\u9000\u51fa\u51b7\u51dd\u5de5\u51b5\uff0c\u6548\u7387\u964d\u81f390%\u4ee5\u4e0b<\/li>\n\n\n\n<li>\u975e\u8282\u80fd\u5efa\u7b51\uff08\u8001\u623f\u3001\u65e0\u4fdd\u6e29\uff09 \u2192 \u70ed\u8d1f\u8377\u53ef\u80fd\u8fbe80-120W\/\u33a1<\/li>\n\n\n\n<li>\u9891\u7e41\u5f00\u7a97\u6362\u6c14 \u2192 \u70ed\u635f\u5931\u589e\u52a020-40%<\/li>\n\n\n\n<li>\u5165\u4f4f\u7387\u4f4e\uff08\u95f4\u6b47\u4f9b\u6696\uff09 \u2192 \u5730\u6696\u5347\u6e29\u6162\uff0c\u9891\u7e41\u542f\u505c\u53cd\u800c\u8d39\u6c14<\/li>\n<\/ul>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">3\u3001\u552e\u540e\u670d\u52a1\u8bb0\u5f55\u4e0e\u89e3\u6790<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65e5\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u4eba\u5458<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u786e\u8ba4<\/th><\/tr><\/thead><tbody><tr><td>\u5e74 \u6708 \u65e5<\/td><td>\u56de\u8bbf<\/td><td><\/td><td>\u8303\u4e3d\u5982<\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u6696\u901a\u00b7<a href=\"tel:13908183204\">\u8303\u4e3d\u5982<\/a><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6863\u6848\u7f16\u53f7\uff1aB-B-W-H-001\u5ba2\u6237\uff1a\u7ba1 [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-982","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u6e56\u4e0e\u767d\u7ba1\u8001\u5e0893\u33a1\u4f4f\u5b85\u63d0\u4f9b\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u745e\u7f8e\u51b7\u51dd\u7089\u5730\u6696\u53ca\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u5168\u6848\u3002\u6863\u6848\u5305\u542b\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u9700\u6c42\u7684\u4e13\u9879\u627f\u8bfa\u3001\u900f\u660e\u62a5\u4ef7\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u53ca\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=982\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u6e56\u4e0e\u767d\u7ba1\u8001\u5e0893\u33a1\u4f4f\u5b85\u63d0\u4f9b\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u745e\u7f8e\u51b7\u51dd\u7089\u5730\u6696\u53ca\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u5168\u6848\u3002\u6863\u6848\u5305\u542b\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u9700\u6c42\u7684\u4e13\u9879\u627f\u8bfa\u3001\u900f\u660e\u62a5\u4ef7\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u53ca\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=982\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-27T10:53:06+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=982\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=982\",\"name\":\"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-18T10:18:04+00:00\",\"dateModified\":\"2026-05-27T10:53:06+00:00\",\"description\":\"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u6e56\u4e0e\u767d\u7ba1\u8001\u5e0893\u33a1\u4f4f\u5b85\u63d0\u4f9b\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u745e\u7f8e\u51b7\u51dd\u7089\u5730\u6696\u53ca\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u5168\u6848\u3002\u6863\u6848\u5305\u542b\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u9700\u6c42\u7684\u4e13\u9879\u627f\u8bfa\u3001\u900f\u660e\u62a5\u4ef7\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u53ca\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=982#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=982\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=982#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848 - \u9f99\u8109\u6696\u901a","description":"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u6e56\u4e0e\u767d\u7ba1\u8001\u5e0893\u33a1\u4f4f\u5b85\u63d0\u4f9b\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u745e\u7f8e\u51b7\u51dd\u7089\u5730\u6696\u53ca\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u5168\u6848\u3002\u6863\u6848\u5305\u542b\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u9700\u6c42\u7684\u4e13\u9879\u627f\u8bfa\u3001\u900f\u660e\u62a5\u4ef7\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u53ca\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=982","og_locale":"zh_CN","og_type":"article","og_title":"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u6e56\u4e0e\u767d\u7ba1\u8001\u5e0893\u33a1\u4f4f\u5b85\u63d0\u4f9b\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u745e\u7f8e\u51b7\u51dd\u7089\u5730\u6696\u53ca\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u5168\u6848\u3002\u6863\u6848\u5305\u542b\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u9700\u6c42\u7684\u4e13\u9879\u627f\u8bfa\u3001\u900f\u660e\u62a5\u4ef7\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u53ca\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=982","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-27T10:53:06+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"10 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=982","url":"https:\/\/longmai-nt.com\/?page_id=982","name":"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-18T10:18:04+00:00","dateModified":"2026-05-27T10:53:06+00:00","description":"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u6e56\u4e0e\u767d\u7ba1\u8001\u5e0893\u33a1\u4f4f\u5b85\u63d0\u4f9b\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u745e\u7f8e\u51b7\u51dd\u7089\u5730\u6696\u53ca\u5929\u51c0\u65b0\u98ce\u7cfb\u7edf\u5168\u6848\u3002\u6863\u6848\u5305\u542b\u9759\u97f3\u3001\u8282\u80fd\u3001\u5065\u5eb7\u9700\u6c42\u7684\u4e13\u9879\u627f\u8bfa\u3001\u900f\u660e\u62a5\u4ef7\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u8ba1\u5212\u53ca\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=982#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=982"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=982#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a \u00b7 \u6e56\u4e0e\u767dG\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u6863\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=982"}],"version-history":[{"count":16,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/982\/revisions"}],"predecessor-version":[{"id":1768,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/982\/revisions\/1768"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}