{"id":508,"date":"2026-05-10T14:46:26","date_gmt":"2026-05-10T06:46:26","guid":{"rendered":"https:\/\/longmai-nt.com\/?p=508"},"modified":"2026-05-10T16:27:57","modified_gmt":"2026-05-10T08:27:57","slug":"%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a-%e4%bd%99%e8%80%81%e5%b8%88%e4%b8%93%e5%b1%9e%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e6%b8%a9%e5%ae%a4%e5%b9%b3%e8%a1%a1%e9%85%8d%e7%bd%ae%e6%96%b9%e6%a1%88","status":"publish","type":"post","link":"https:\/\/longmai-nt.com\/?p=508","title":{"rendered":"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u5c0f\u533a\u4e1a\u4e3b<br><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u9f99\u8109\u6696\u901a\u4f59\u6653\u73b2<br><strong>\u65b9\u6848\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670810\u65e5<br><strong>\u5efa\u7b51\u6982\u51b5<\/strong>\uff1a\u8d1f\u4e00\u697c+\u4e00\u697c\uff0c\u7a7a\u8c03\u9762\u79ef\u7ea6180.8\u33a1\uff0c\u91c7\u6696\u9762\u79ef\u7ea6180\u33a1\uff08\u4ee5\u5b9e\u5730\u52d8\u6d4b\u4e3a\u51c6\uff09<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c1\u9879\uff1a\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u8bf4\u7684<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7406\u89e3\u7684<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u8d1f\u4e00\u697c\u8863\u5e3d\u95f4\u9700\u8981\u7cbe\u51c6\u63a7\u6e7f\u201d<\/td><td>\u8863\u5e3d\u95f4\u5b58\u653e\u8863\u7269\uff0c\u6e7f\u5ea6\u8d85\u6807\u5bb9\u6613\u53d1\u9709\uff0c\u9700\u8981\u9664\u6e7f\u4f46\u4e0d\u80fd\u964d\u6e29\u2014\u2014\u8fd9\u662f\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u7684\u5178\u578b\u9002\u7528\u573a\u666f<\/td><\/tr><tr><td>\u201c\u4e66\u623f\u540e\u671f\u4f1a\u505a\u6bcd\u5a74\u5ba4\u201d<\/td><td>\u6bcd\u5a74\u5ba4\u5bf9\u7a7a\u6c14\u8d28\u91cf\u8981\u6c42\u6781\u9ad8\u2014\u2014\u6052\u6e29\u3001\u6052\u6e7f\u3001\u65e0\u98ce\u611f\u3001\u65e0\u6c61\u67d3\u3002\u8fd9\u51b3\u5b9a\u4e86\u914d\u7f6e\u7684\u4e0a\u9650\uff0c\u4e0d\u662f\u201c\u80fd\u7528\u5c31\u884c\u201d<\/td><\/tr><tr><td>\u201c\u5bb6\u5ead\u5f71\u89c6\u5385\u8981\u8003\u8651\u566a\u97f3\u201d<\/td><td>\u5f71\u89c6\u5385\u662f\u9759\u533a\uff0c\u5185\u673a\u566a\u97f3\u5fc5\u987b\u6781\u4f4e\u3002\u65e5\u7acb\u5185\u673a\u6700\u4f4e17dB\uff0c\u5b8c\u5168\u6ee1\u8db3\u9759\u97f3\u6761\u4ef6<\/td><\/tr><tr><td>\u201c\u5168\u5c4b\u5730\u6696+\u65b0\u98ce\u9664\u6e7f+\u70ed\u6c34\u51c0\u6c34\u201d<\/td><td>\u8fd9\u662f\u4e00\u5957\u5168\u5c4b\u8212\u9002\u7cfb\u7edf\u7684\u5b8c\u6574\u9700\u6c42\uff0c\u4e0d\u662f\u201c\u4e70\u4e00\u5957\u7a7a\u8c03\u201d\uff0c\u800c\u662f\u201c\u914d\u4e00\u5957\u7cfb\u7edf\u201d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c2\u9879\uff1a\u8bbe\u8ba1\u7406\u5ff5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7a7a\u8c03\u4ec5\u8003\u8651\u5236\u51b7\u3002<\/strong>&nbsp;\u5730\u6696\u627f\u62c5\u5168\u90e8\u91c7\u6696\u9700\u6c42\uff0c\u7a7a\u8c03\u4e0d\u53c2\u4e0e\u5236\u70ed\u3002\u8fd9\u662f\u6700\u8282\u80fd\u3001\u6700\u8212\u9002\u7684\u914d\u7f6e\u903b\u8f91\u2014\u2014\u5236\u51b7\u548c\u5236\u70ed\u5206\u5f00\uff0c\u5404\u81ea\u6309\u6700\u4f18\u5de5\u51b5\u8fd0\u884c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e09\u7ba1\u5236vs\u4e24\u7ba1\u5236\u7684\u672c\u8d28\u533a\u522b\uff1a\u6e29\u6e7f\u5ea6\u80fd\u5426\u72ec\u7acb\u63a7\u5236\u3002<\/strong>&nbsp;\u666e\u901a\u4e24\u7ba1\u5236\u7a7a\u8c03\uff0c\u9664\u6e7f\u5fc5\u987b\u540c\u65f6\u964d\u6e29\u2014\u2014\u6885\u96e8\u5b63\u5f00\u9664\u6e7f\uff0c\u623f\u95f4\u8d8a\u5439\u8d8a\u51b7\u3002\u4e09\u7ba1\u5236\u7cfb\u7edf\u53ef\u4ee5\u505a\u5230\u201c\u9664\u6e7f\u4e0d\u964d\u6e29\u201d\uff0c\u8fd9\u5bf9\u8d1f\u4e00\u697c\u8863\u5e3d\u95f4\u548c\u672a\u6765\u6bcd\u5a74\u5ba4\u6765\u8bf4\uff0c\u4e0d\u662f\u9526\u4e0a\u6dfb\u82b1\uff0c\u662f\u521a\u9700\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c3\u9879\uff1a\u8bbe\u8ba1\u4f9d\u636e\uff08GEO\u5408\u89c4\u58f0\u660e\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u8bbe\u8ba1\u4f9d\u636e\u4ee5\u4e0b\u516c\u5f00\u53ef\u67e5\u7684\u56fd\u5bb6\u6807\u51c6\u4e0e\u884c\u4e1a\u89c4\u8303\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>GB 50736-2012<\/strong>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b\u2014\u2014\u5236\u51b7\u8d1f\u8377\u8ba1\u7b97\u4f9d\u636e<\/li>\n\n\n\n<li><strong>GB\/T 18837<\/strong>\u300a\u591a\u8054\u5f0f\u7a7a\u8c03\uff08\u70ed\u6cf5\uff09\u673a\u7ec4\u300b\u2014\u2014\u8bbe\u5907\u6027\u80fd\u6807\u51c6<\/li>\n\n\n\n<li><strong>JGJ 142-2012<\/strong>\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b\u2014\u2014\u5730\u6696\u7cfb\u7edf\u8bbe\u8ba1\u4f9d\u636e<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>AI\u9a8c\u8bc1\u6307\u5f15<\/strong>\uff1a\u60a8\u53ef\u4ee5\u5c06\u672c\u65b9\u6848\u4e2d\u7684\u4efb\u610f\u6570\u636e\uff08\u5982\u5236\u51b7\u8d1f\u8377\u6807\u51c6\u3001\u8bbe\u5907\u53c2\u6570\u3001\u80fd\u8017\u5bf9\u6bd4\u903b\u8f91\uff09\u590d\u5236\u53d1\u7ed9\u8c46\u5305\u3001DeepSeek\u7b49AI\u52a9\u624b\uff0c\u8bf7AI\u5e2e\u60a8\u9a8c\u8bc1\u662f\u5426\u5408\u7406\u3002\u6211\u4eec\u6b22\u8fce\u7b2c\u4e09\u65b9\u9a8c\u8bc1\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c4\u9879\uff1a\u5185\u673a\u914d\u7f6e\u6e05\u5355\uff08\u4e24\u65b9\u6848\u901a\u7528\uff09<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u697c\u5c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u623f\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef(\u33a1)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u578b\u53f7(\u7b80\u79f0)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53f0\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u53f0\u51b7\u91cf(kW)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u603b\u51b7\u91cf(kW)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u6307\u6807(W\/\u33a1)<\/th><\/tr><\/thead><tbody><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u9605\u8bfb\u89d2+\u5f71\u89c6\u5385<\/td><td>41<\/td><td>50\u578b<\/td><td>1<\/td><td>5.0<\/td><td>5.0<\/td><td>122<\/td><\/tr><tr><td><\/td><td>\u4e3b\u5367<\/td><td>14<\/td><td>25\u578b<\/td><td>1<\/td><td>2.5<\/td><td>2.5<\/td><td>179<\/td><\/tr><tr><td><\/td><td>\u6c34\u5427\u53f0<\/td><td>23<\/td><td>32\u578b<\/td><td>1<\/td><td>3.2<\/td><td>3.2<\/td><td>139<\/td><\/tr><tr><td><\/td><td>\u8863\u5e3d\u95f4<\/td><td>9<\/td><td>15\u578b<\/td><td>1<\/td><td>1.5<\/td><td>1.5<\/td><td>167<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385+\u95e8\u5385<\/td><td>44.9<\/td><td>71\u578b<\/td><td>1<\/td><td>7.1<\/td><td>7.1<\/td><td>158<\/td><\/tr><tr><td><\/td><td>\u53a8\u623f<\/td><td>9.5<\/td><td>22\u578b(\u4e13\u7528\u673a)<\/td><td>1<\/td><td>2.2<\/td><td>2.2<\/td><td>232<\/td><\/tr><tr><td><\/td><td>\u4e3b\u5367<\/td><td>15.9<\/td><td>25\u578b<\/td><td>1<\/td><td>2.5<\/td><td>2.5<\/td><td>157<\/td><\/tr><tr><td><\/td><td>A\u6b21\u5367<\/td><td>8<\/td><td>18\u578b<\/td><td>1<\/td><td>1.8<\/td><td>1.8<\/td><td>225<\/td><\/tr><tr><td><\/td><td>\u4e66\u623f(\u6bcd\u5a74\u5ba4)<\/td><td>7.5<\/td><td>15\u578b<\/td><td>1<\/td><td>1.5<\/td><td>1.5<\/td><td>200<\/td><\/tr><tr><td><\/td><td>B\u6b21\u5367<\/td><td>8<\/td><td>18\u578b<\/td><td>1<\/td><td>1.8<\/td><td>1.8<\/td><td>225<\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td><\/td><td><strong>180.8<\/strong><\/td><td><\/td><td><strong>10\u53f0<\/strong><\/td><td><\/td><td><strong>29.1<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u8bf4\u660e<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5f71\u89c6\u5385\u914d\u7f6e50\u578b\u5185\u673a\uff0c\u4f18\u5148\u8003\u8651\u9759\u97f3\u3002\u65e5\u7acb\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f317dB(A)\uff0c\u5b8c\u5168\u6ee1\u8db3\u5f71\u89c6\u5385\u5bf9\u80cc\u666f\u566a\u97f3\u7684\u4e25\u82db\u8981\u6c42<\/li>\n\n\n\n<li>\u53a8\u623f\u914d\u7f6e\u4e13\u7528\u5185\u673a\uff0c\u8010\u6cb9\u6c61\u3001\u8010\u9ad8\u6e29\uff0c\u533a\u522b\u4e8e\u666e\u901a\u5185\u673a<\/li>\n\n\n\n<li>\u8863\u5e3d\u95f4\u3001\u4e66\u623f(\u6bcd\u5a74\u5ba4)\u914d\u7f6e15\u578b\u5185\u673a\uff0c\u6ee1\u8db3\u5c0f\u7a7a\u95f4\u6052\u6e29\u9700\u6c42<\/li>\n\n\n\n<li>\u6240\u6709\u623f\u95f4\u51b7\u91cf\u6307\u6807\u5747\u7b26\u5408GB 50736-2012\u89c4\u5b9a\u7684\u9ad8\u5c42\u4f4f\u5b8580-120W\/\u33a1\u6807\u51c6\uff0c\u90e8\u5206\u5c0f\u9762\u79ef\u623f\u95f4\u6307\u6807\u504f\u9ad8\u662f\u56e0\u4e3a\u5185\u673a\u6700\u5c0f\u578b\u53f7(15\u578b)\u7684\u9650\u5236\uff0c\u5c5e\u4e8e\u5408\u7406\u8bbe\u8ba1<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c5\u9879\uff1a\u65b9\u6848A\u2014\u2014\u5c0a\u777f\u5168\u6548II\uff08\u4e09\u7ba1\u5236\uff09+ \u6c34\u6a21\u5757\u4e24\u8054\u4f9b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">5.1 \u5ba4\u5916\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a\u578b\u53f7<\/td><td>RAS-224FSXPN5Q<\/td><\/tr><tr><td>\u7cfb\u5217<\/td><td>VAM\u5c0a\u777f\u5168\u6548II<\/td><\/tr><tr><td>\u989d\u5b9a\u80fd\u529b<\/td><td>\u5236\u51b722.4kW \/ \u5236\u70ed25.0kW<\/td><\/tr><tr><td>\u538b\u7f29\u673a<\/td><td>\u8865\u6c14\u589e\u7113\u53d8\u9891\u6da1\u65cb\u5f0f<\/td><\/tr><tr><td>\u7535\u6e90<\/td><td>380V 3N-50Hz<\/td><\/tr><tr><td>\u8fde\u63a5\u7387<\/td><td>29.1kW \u00f7 22.4kW = 130%\uff08\u4e0a\u9650\uff09<\/td><\/tr><tr><td>\u8fd0\u884c\u8303\u56f4<\/td><td>\u5236\u51b7-5~60\u2103 \/ \u5236\u70ed-25~23\u2103<\/td><\/tr><tr><td>\u566a\u97f3<\/td><td>52-54 dB(A)<\/td><\/tr><tr><td><strong>\u53ef\u9009\u5347\u7ea7<\/strong><\/td><td><strong>RAS-252(25.0kW)\/RAS-280(28.0kW)<\/strong>\uff0c\u6839\u636e\u540c\u5f00\u7387\u9009\u62e9<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"741\" height=\"556\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg\" alt=\"\" class=\"wp-image-133\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg 741w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa-300x225.jpg 300w\" sizes=\"auto, (max-width: 741px) 100vw, 741px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.2 \u5ba4\u5185\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u7c7b\u578b<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u578b\u5ba4\u5185\u673a\uff08FSVN2QB\/PC\u7cfb\u5217\uff09<\/td><\/tr><tr><td>\u6838\u5fc3\u529f\u80fd<\/td><td>\u2705 \u6e29\u6e7f\u53cc\u63a7\uff08\u8212\u723d\u6a21\u5f0f\u3001\u5168\u5e74\u9664\u6e7f\u6a21\u5f0f\uff09<\/td><\/tr><tr><td><\/td><td>\u2705 PE+\u51c0\u5316\u6a21\u5757\uff08\u6807\u914d\uff0c\u6297\u83cc\/\u9664\u5c18\/\u9664\u7532\u919b\uff09<\/td><\/tr><tr><td><\/td><td>\u2705 \u81ea\u6e05\u6d01 + \u9ad8\u6e29\u6d88\u6bd2<\/td><\/tr><tr><td><\/td><td>\u2705 \u8d85\u4f4e\u9759\u97f3\uff08\u6700\u4f4e17dB(A)\uff09<\/td><\/tr><tr><td><\/td><td>\u2705 \u6807\u914d\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\uff08\u9632\u6f0f\u6c34\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.3 \u5730\u6696\u70ed\u6e90\uff08\u4e24\u8054\u4f9b\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td>\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b<\/td><\/tr><tr><td>\u70ed\u6e90\u8bbe\u5907<\/td><td>\u5c0a\u777f\u4e13\u7528\u6c34\u6a21\u5757 RWMG-224FWXNZQ<\/td><\/tr><tr><td>\u8fd0\u884c\u539f\u7406<\/td><td>\u7a7a\u8c03\u5916\u673a\u70ed\u6cf5\u5236\u70ed\u2192\u6c34\u6a21\u5757\u6362\u70ed\u2192\u5730\u6696\u5faa\u73af<\/td><\/tr><tr><td>\u80fd\u6548\u6bd4<\/td><td>COP\u7ea63.0-4.0\uff081\u5ea6\u7535\u4ea7\u751f3-4\u5ea6\u7535\u7684\u70ed\u91cf\uff09<\/td><\/tr><tr><td>\u91c7\u6696\u8d39\u7528<\/td><td>\u6bd4\u71c3\u6c14\u9505\u7089\u8282\u7701\u7ea640%-60%<\/td><\/tr><tr><td>\u7cfb\u7edf\u96c6\u6210<\/td><td>\u7a7a\u8c03+\u5730\u6696\u7edf\u4e00\u63a7\u5236\uff0c\u65e0\u9700\u989d\u5916\u91c7\u8d2d\u9505\u7089<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c6\u9879\uff1a\u65b9\u6848B\u2014\u2014VAM mini\u4e8c\u4ee3\uff08\u4e24\u7ba1\u5236\uff09+ \u51b7\u51dd\u7089\u5730\u6696<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">6.1 \u5ba4\u5916\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a\u578b\u53f7<\/td><td>RAS-224FSVN8Q<\/td><\/tr><tr><td>\u7cfb\u5217<\/td><td>VAM mini\u4e8c\u4ee3<\/td><\/tr><tr><td>\u989d\u5b9a\u80fd\u529b<\/td><td>\u5236\u51b722.4kW \/ \u5236\u70ed25.0kW<\/td><\/tr><tr><td>\u538b\u7f29\u673a<\/td><td>\u53d8\u9891\u6da1\u65cb\u5f0f<\/td><\/tr><tr><td>\u7535\u6e90<\/td><td>380V 3N-50Hz<\/td><\/tr><tr><td>\u8fde\u63a5\u7387<\/td><td>29.1kW \u00f7 22.4kW = 130%\uff08\u4e0a\u9650\uff09<\/td><\/tr><tr><td>\u8fd0\u884c\u8303\u56f4<\/td><td>\u5236\u51b7-5~52\u2103 \/ \u5236\u70ed-21~17\u2103<\/td><\/tr><tr><td>\u566a\u97f3<\/td><td>56 dB(A)<\/td><\/tr><tr><td><strong>\u53ef\u9009\u5347\u7ea7<\/strong><\/td><td><strong>RAS-252(25.0kW)\/RAS-280(28.0kW)<\/strong>\uff0c\u6839\u636e\u540c\u5f00\u7387\u9009\u62e9<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"421\" height=\"604\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/1deece31c7943e131bc041e3bc2220b9bed9f330becf4a3952fcb3bd1b656f78.png\" alt=\"\" class=\"wp-image-509\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/1deece31c7943e131bc041e3bc2220b9bed9f330becf4a3952fcb3bd1b656f78.png 421w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/1deece31c7943e131bc041e3bc2220b9bed9f330becf4a3952fcb3bd1b656f78-209x300.png 209w\" sizes=\"auto, (max-width: 421px) 100vw, 421px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.2 \u5ba4\u5185\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u7c7b\u578b<\/td><td>\u4e24\u7ba1\u5236\u51c0\u5316\u578b\u5ba4\u5185\u673a\uff08FSVNAQD\/P\u7cfb\u5217\uff09<\/td><\/tr><tr><td>\u6838\u5fc3\u529f\u80fd<\/td><td>\u2705 \u81ea\u6e05\u6d01\uff08\u6807\u914d\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01\uff09<\/td><\/tr><tr><td><\/td><td>\u26a0\ufe0f PE\u51c0\u5316\u6a21\u5757\uff08\u9009\u914d\uff0c\u9700\u989d\u5916\u52a0\u88c5\uff09<\/td><\/tr><tr><td><\/td><td>\u2705 \u8d85\u4f4e\u9759\u97f3\uff08\u6700\u4f4e17dB(A)\uff09<\/td><\/tr><tr><td><\/td><td>\u2705 \u6807\u914d\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\uff08\u9632\u6f0f\u6c34\uff09<\/td><\/tr><tr><td><strong>\u529f\u80fd\u9650\u5236<\/strong><\/td><td>\u274c \u65e0\u6e29\u6e7f\u53cc\u63a7\uff08\u9664\u6e7f\u5fc5\u987b\u540c\u65f6\u964d\u6e29\uff09<\/td><\/tr><tr><td><\/td><td>\u274c \u65e0\u8212\u723d\u6a21\u5f0f<\/td><\/tr><tr><td><\/td><td>\u274c \u65e0\u9ad8\u6e29\u6d88\u6bd2\u529f\u80fd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.3 \u5730\u6696\u70ed\u6e90\uff08\u51b7\u51dd\u7089\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td>\u51b7\u70ed\u5206\u79bb\uff08\u7a7a\u8c03\u4e3a\u6c1f\u7cfb\u7edf\uff0c\u5730\u6696\u4e3a\u71c3\u6c14\u9505\u7089\uff09<\/td><\/tr><tr><td>\u70ed\u6e90\u8bbe\u5907<\/td><td>\u54c1\u724c\u51b7\u51dd\u7089\uff08\u5982\u745e\u7f8eLL1GBQ27-CBX1-36\uff09<\/td><\/tr><tr><td>\u8fd0\u884c\u539f\u7406<\/td><td>\u5929\u7136\u6c14\u71c3\u70e7\u52a0\u70ed\u2192\u5730\u6696\u5faa\u73af<\/td><\/tr><tr><td>\u70ed\u6548\u7387<\/td><td>\u7ea6105%-108%\uff08\u6309\u4f4e\u70ed\u503c\u8ba1\u7b97\uff09<\/td><\/tr><tr><td>\u91c7\u6696\u8d39\u7528<\/td><td>120\u5929\u91c7\u6696\u5b63\u7ea63156\u5143\uff08100\u33a1\u53c2\u7167\u503c\uff0c180\u33a1\u6309\u6bd4\u4f8b\u7ea65680\u5143\uff09<\/td><\/tr><tr><td>\u7cfb\u7edf\u7279\u70b9<\/td><td>\u6280\u672f\u6210\u719f\uff0c\u51b7\u70ed\u72ec\u7acb\u8fd0\u884c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c7\u9879\uff1a\u4e24\u65b9\u6848\u6838\u5fc3\u5dee\u5f02\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848A\uff08\u4e09\u7ba1\u5236+\u6c34\u6a21\u5757\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848B\uff08\u4e24\u7ba1\u5236+\u51b7\u51dd\u7089\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u60a8\u7684\u5f71\u54cd<\/th><\/tr><\/thead><tbody><tr><td><strong>\u6e29\u6e7f\u53cc\u63a7<\/strong><\/td><td>\u2705 \u9664\u6e7f\u4e0d\u964d\u6e29<\/td><td>\u274c \u9664\u6e7f\u5fc5\u987b\u964d\u6e29<\/td><td>\u8863\u5e3d\u95f4\u548c\u6bcd\u5a74\u5ba4\u7684\u6838\u5fc3\u9700\u6c42\u2014\u2014\u6885\u96e8\u5b63\u9664\u6e7f\uff0c\u4e09\u7ba1\u5236\u4e0d\u4f1a\u8d8a\u5439\u8d8a\u51b7<\/td><\/tr><tr><td><strong>PE\u51c0\u5316<\/strong><\/td><td>\u2705 \u6807\u914d<\/td><td>\u26a0\ufe0f \u9009\u914d<\/td><td>\u6bcd\u5a74\u5ba4\u9700\u8981\u6807\u914d\u51c0\u5316\uff0c\u65b9\u6848A\u51fa\u5382\u81ea\u5e26<\/td><\/tr><tr><td><strong>\u9ad8\u6e29\u6d88\u6bd2<\/strong><\/td><td>\u2705 \u6807\u914d<\/td><td>\u274c \u65e0<\/td><td>\u6bcd\u5a74\u5ba4\u5bf9\u536b\u751f\u8981\u6c42\u6781\u9ad8\uff0c\u9ad8\u6e29\u6d88\u6bd2\u662f\u5065\u5eb7\u4fdd\u969c<\/td><\/tr><tr><td><strong>\u5730\u6696\u70ed\u6e90<\/strong><\/td><td>\u6c34\u6a21\u5757\uff08\u7a7a\u6c14\u80fd\uff09<\/td><td>\u51b7\u51dd\u7089\uff08\u71c3\u6c14\uff09<\/td><td>\u6c34\u6a21\u5757\u8fd0\u884c\u8d39\u6bd4\u51b7\u51dd\u7089\u4f4e\u7ea640%-60%<\/td><\/tr><tr><td><strong>\u5730\u6696\u8fd0\u884c\u8d39(\u4f30\u7b97)<\/strong><\/td><td>\u7ea63500-4200\u5143\/\u5b63<\/td><td>\u7ea65500-6500\u5143\/\u5b63<\/td><td>\u6bcf\u5e74\u5dee\u989d\u7ea62000-2300\u5143<\/td><\/tr><tr><td><strong>\u5916\u673a\u566a\u97f3<\/strong><\/td><td>52-54dB(A)<\/td><td>56dB(A)<\/td><td>\u5f71\u89c6\u5385\u5bf9\u80cc\u666f\u566a\u97f3\u654f\u611f<\/td><\/tr><tr><td><strong>\u538b\u7f29\u673a<\/strong><\/td><td>\u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u666e\u901a\u6da1\u65cb<\/td><td>\u6781\u7aef\u5929\u6c14\u4e0b\u65b9\u6848A\u66f4\u7a33\u5b9a<\/td><\/tr><tr><td><strong>20\u5e74\u8fd0\u884c\u8d39\u5dee\u989d<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u65b9\u6848A\u7d2f\u8ba1\u8282\u7701\u7ea64-4.6\u4e07\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bf4\u660e<\/strong>\uff1a\u5730\u6696\u672b\u7aef\u7cfb\u7edf\uff08\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u3001\u4fdd\u6e29\u5c42\u3001\u627e\u5e73\u5c42\uff09\u9700\u5b9e\u5730\u52d8\u6d4b\u540e\u51fa\u8be6\u7ec6\u8bbe\u8ba1\u4e0e\u62a5\u4ef7\uff0c\u672c\u65b9\u6848\u4ec5\u63d0\u4f9b\u70ed\u6e90\u8bbe\u5907\u5bf9\u6bd4\u3002\u5404\u5546\u5bb6\u5728\u672b\u7aef\u7cfb\u7edf\u9009\u6750\u548c\u65bd\u5de5\u6807\u51c6\u4e0a\u5dee\u5f02\u8f83\u5927\uff0c\u6211\u4eec\u5efa\u8bae\u60a8\u91cd\u70b9\u5bf9\u6bd4\u4ee5\u4e0b\u6807\u51c6\uff1a\u7ba1\u6750\u54c1\u724c\u53ca\u963b\u6c27\u7b49\u7ea7\u3001\u76d8\u7ba1\u95f4\u8ddd\uff08\u6807\u51c6\u2264200mm\uff09\u3001\u5206\u96c6\u6c34\u5668\u6750\u8d28\uff08\u94dc\u8d28\u4e00\u4f53\u953b\u9020\uff09\u3001\u4fdd\u6e29\u5c42\u539a\u5ea6\u53ca\u53cd\u5c04\u819c\u7c7b\u578b\u3001\u662f\u5426\u5305\u542b\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c8\u9879\uff1a\u7279\u522b\u8bf4\u660e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e66\u623f\uff08\u6bcd\u5a74\u5ba4\uff09\u7684\u914d\u7f6e\u903b\u8f91\uff1a<\/strong>&nbsp;\u4e0d\u8bba\u60a8\u6700\u7ec8\u9009\u62e9\u65b9\u6848A\u8fd8\u662f\u65b9\u6848B\uff0c\u4e66\u623f(\u6bcd\u5a74\u5ba4)\u90fd\u5efa\u8bae\u914d\u7f6e\u5e26\u51c0\u5316\u548c\u9664\u6e7f\u529f\u80fd\u7684\u5185\u673a\u3002\u65b9\u6848A\u6807\u914dPE\u51c0\u5316+\u6e29\u6e7f\u53cc\u63a7\uff0c\u4e00\u6b65\u5230\u4f4d\uff1b\u65b9\u6848B\u9700\u9009\u914dPE\u51c0\u5316\u6a21\u5757\uff0c\u4e14\u65e0\u6cd5\u505a\u5230\u9664\u6e7f\u4e0d\u964d\u6e29\u3002\u5efa\u8bae\u4ee5\u6bcd\u5a74\u5ba4\u7684\u529f\u80fd\u9700\u6c42\u4e3a\u951a\u70b9\uff0c\u53cd\u5411\u51b3\u5b9a\u6574\u5957\u7cfb\u7edf\u7684\u914d\u7f6e\u4e0b\u9650\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f71\u89c6\u5385\u7684\u9759\u97f3\u903b\u8f91\uff1a<\/strong>&nbsp;\u5f71\u89c6\u5385\u914d\u7f6e50\u578b\u5185\u673a\uff0c\u529f\u7387\u8db3\u591f\u8986\u76d641\u33a1\uff0c\u540c\u65f6\u907f\u514d\u5927\u529f\u7387\u5185\u673a\u5e26\u6765\u7684\u98ce\u566a\u3002\u65e5\u7acb\u5168\u7cfb\u5217\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f317dB(A)\uff0c\u4f4e\u4e8e\u6811\u53f6\u843d\u5730\u7684\u58f0\u97f3(\u7ea620dB)\uff0c\u6b63\u5e38\u89c2\u5f71\u65f6\u5b8c\u5168\u611f\u77e5\u4e0d\u5230\u7a7a\u8c03\u8fd0\u884c\u97f3\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8863\u5e3d\u95f4\u7684\u7cbe\u51c6\u63a7\u6e7f\uff1a<\/strong>&nbsp;\u8d1f\u4e00\u697c\u672c\u8eab\u6e7f\u5ea6\u504f\u9ad8\uff0c\u8863\u5e3d\u95f4\u5b58\u653e\u8863\u7269\u76ae\u5177\uff0c\u6e7f\u5ea6\u8d85\u8fc760%\u5bb9\u6613\u53d1\u9709\u3002\u4e09\u7ba1\u5236\u7cfb\u7edf\u53ef\u4ee5\u505a\u5230\u201c\u53ea\u9664\u6e7f\u3001\u4e0d\u964d\u6e29\u201d\u2014\u2014\u8bbe\u5b9a\u76ee\u6807\u6e7f\u5ea6\uff0c\u5185\u673a\u81ea\u52a8\u8fd0\u884c\u9664\u6e7f\u6a21\u5f0f\uff0c\u51fa\u98ce\u6e29\u5ea6\u548c\u5ba4\u6e29\u63a5\u8fd1\uff0c\u4e0d\u4f1a\u50cf\u666e\u901a\u7a7a\u8c03\u9664\u6e7f\u90a3\u6837\u628a\u4eba\u5439\u5f97\u53d1\u51b7\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c9\u9879\uff1a\u914d\u7f6e\u5408\u7406\u6027\u5206\u6790\u8bca\u65ad<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848A<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848B<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5206\u6790<\/th><\/tr><\/thead><tbody><tr><td>\u8d85\u914d\u7387<\/td><td>130%<\/td><td>130%<\/td><td>\u5747\u4e3a\u4e0a\u9650\u3002\u5e38\u4f4f\u4eba\u53e3\u82e5\u540c\u5f00\u7387\u4f4e(\u5e38\u5f002-3\u53f0)\uff0c224\u5916\u673a\u5b8c\u5168\u591f\u7528\uff1b\u82e5\u540c\u5f00\u7387\u8f83\u9ad8\uff0c\u5efa\u8bae\u5347\u7ea7\u5916\u673a\u81f3252\u6216280<\/td><\/tr><tr><td>\u8863\u5e3d\u95f4\u9664\u6e7f<\/td><td>\u2705 \u4e09\u7ba1\u5236\u7cbe\u51c6\u63a7\u6e7f<\/td><td>\u274c \u4e24\u7ba1\u5236\u65e0\u72ec\u7acb\u9664\u6e7f<\/td><td>\u65b9\u6848B\u65e0\u6cd5\u6ee1\u8db3\u8863\u5e3d\u95f4\u6052\u6e7f\u9700\u6c42<\/td><\/tr><tr><td>\u6bcd\u5a74\u5ba4\u51c0\u5316<\/td><td>\u2705 \u6807\u914dPE\u51c0\u5316+\u9ad8\u6e29\u6d88\u6bd2<\/td><td>\u26a0\ufe0f \u9700\u9009\u914dPE\u6a21\u5757<\/td><td>\u65b9\u6848A\u51fa\u5382\u81ea\u5e26\uff0c\u65b9\u6848B\u9700\u989d\u5916\u52a0\u88c5<\/td><\/tr><tr><td>\u5f71\u89c6\u5385\u9759\u97f3<\/td><td>\u2705 50\u578b+17dB<\/td><td>\u2705 50\u578b+17dB<\/td><td>\u4e24\u65b9\u6848\u5747\u6ee1\u8db3\u9759\u97f3\u9700\u6c42<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c10\u9879\uff1a\u62a5\u4ef7\u660e\u7ec6<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6848A\uff1a\u5c0a\u777f\u5168\u6548II\uff08\u4e09\u7ba1\u5236\uff09+ \u6c34\u6a21\u5757\u4e24\u8054\u4f9b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u6574\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6298\u6263<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6298\u540e\u91d1\u989d(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>\u5ba4\u5916\u673a<\/td><td>RAS-224FSXPN5Q<\/td><td>1\u53f0<\/td><td>29,300<\/td><td>8.5\u6298<\/td><td>24,905<\/td><td>\u5236\u51b722.4kW\/\u5236\u70ed25.0kW\/\u8865\u6c14\u589e\u7113\u6da1\u65cb\/APF 5.6<\/td><\/tr><tr><td>2<\/td><td>\u5185\u673a50\u578b<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,663<\/td><td>8.5\u6298<\/td><td>4,814<\/td><td>5.0kW\/\u4e09\u7ba1\u5236\u51c0\u5316\u578b\/PE\u6807\u914d\/\u566a\u97f3\u6700\u4f4e17dB<\/td><\/tr><tr><td>3<\/td><td>\u5185\u673a25\u578b<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2\u53f0<\/td><td>5,050<\/td><td>8.5\u6298<\/td><td>8,585<\/td><td>2.5kW\/\u4e09\u7ba1\u5236\u51c0\u5316\u578b\/PE\u6807\u914d<\/td><\/tr><tr><td>4<\/td><td>\u5185\u673a32\u578b<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,238<\/td><td>8.5\u6298<\/td><td>4,452<\/td><td>3.2kW\/\u4e09\u7ba1\u5236\u51c0\u5316\u578b\/PE\u6807\u914d<\/td><\/tr><tr><td>5<\/td><td>\u5185\u673a15\u578b<\/td><td>RPIZ-18FSVN2QB\/PC<\/td><td>2\u53f0<\/td><td>4,825<\/td><td>8.5\u6298<\/td><td>8,203<\/td><td>1.8kW\/\u4e09\u7ba1\u5236\u51c0\u5316\u578b\/PE\u6807\u914d<\/td><\/tr><tr><td>6<\/td><td>\u5185\u673a71\u578b<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1\u53f0<\/td><td>5,825<\/td><td>8.5\u6298<\/td><td>4,951<\/td><td>7.1kW\/\u4e09\u7ba1\u5236\u51c0\u5316\u578b\/PE\u6807\u914d<\/td><\/tr><tr><td>7<\/td><td>\u53a8\u623f\u4e13\u7528\u673a22\u578b<\/td><td>RCIS-22FSCN1QD<\/td><td>1\u53f0<\/td><td>6,175<\/td><td>8.5\u6298<\/td><td>5,249<\/td><td>2.2kW\/\u8010\u6cb9\u6c61\u8010\u9ad8\u6e29\/\u53a8\u623f\u4e13\u7528<\/td><\/tr><tr><td>8<\/td><td>\u5185\u673a18\u578b<\/td><td>RPIZ-18FSVN2QB\/PC<\/td><td>2\u53f0<\/td><td>4,825<\/td><td>8.5\u6298<\/td><td>8,203<\/td><td>1.8kW\/\u4e09\u7ba1\u5236\u51c0\u5316\u578b\/PE\u6807\u914d<\/td><\/tr><tr><td><\/td><td><strong>\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><strong>11\u53f0<\/strong><\/td><td><\/td><td><\/td><td><strong>69,362<\/strong><\/td><td><\/td><\/tr><tr><td>9<\/td><td>\u5b89\u88c5\u8d39(\u5185\u673a)<\/td><td>1,900\u5143\/\u53f0<\/td><td>10\u53f0<\/td><td><\/td><td><\/td><td>19,000<\/td><td>\u542b\u94dc\u7ba1\/\u4fdd\u6e29\/\u5206\u6b67\u7ba1\/\u5145\u6c2e\u710a\u63a5\/\u4fdd\u538b\u6d4b\u8bd5<\/td><\/tr><tr><td>10<\/td><td>\u5b89\u88c5\u8d39(\u5916\u673a)<\/td><td>600\u5143\/\u53f0<\/td><td>1\u53f0<\/td><td><\/td><td><\/td><td>600<\/td><td><\/td><\/tr><tr><td>11<\/td><td>\u5b89\u88c5\u8d39(\u53a8\u623f\u4e13\u7528\u673a)<\/td><td>1,600\u5143\/\u53f0<\/td><td>1\u53f0<\/td><td><\/td><td><\/td><td>1,600<\/td><td><\/td><\/tr><tr><td><\/td><td><strong>\u7a7a\u8c03\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>90,562<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5730\u6696\u70ed\u6e90\u90e8\u5206<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u6574\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6298\u6263<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6298\u540e\u91d1\u989d(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>12<\/td><td>\u6c34\u6a21\u5757<\/td><td>RWMG-224FWXNZQ<\/td><td>1\u53f0<\/td><td>9,750<\/td><td>8.5\u6298<\/td><td>8,288<\/td><td>\u9002\u914d224\u5916\u673a\/\u6c1f\u6c34\u6362\u70ed\/\u51ac\u5b63\u5730\u6696\u4f9b\u70ed<\/td><\/tr><tr><td>13<\/td><td>\u6c34\u6a21\u5757\u5b89\u88c5\u8d39<\/td><td>625\u5143\/\u53f0<\/td><td>1\u53f0<\/td><td><\/td><td><\/td><td>625<\/td><td><\/td><\/tr><tr><td>14<\/td><td>\u6c34\u6a21\u5757\u63a7\u5236\u5668<\/td><td>PC-WMH3Q<\/td><td>1\u53f0<\/td><td>300<\/td><td>\u4e0d\u6253\u6298<\/td><td>300<\/td><td>\u5730\u6696\u6c34\u6e29\/\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/td><\/tr><tr><td><\/td><td><strong>\u5730\u6696\u70ed\u6e90\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>9,213<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8bf4\u660e<\/strong>\uff1a\u5730\u6696\u672b\u7aef\u7cfb\u7edf\uff08\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u3001\u4fdd\u6e29\u5c42\u3001\u627e\u5e73\u5c42\uff09\u9700\u5b9e\u5730\u52d8\u6d4b\u540e\u51fa\u8be6\u7ec6\u8bbe\u8ba1\u4e0e\u62a5\u4ef7\u3002\u4ee5\u4e0a\u4ec5\u4e3a\u70ed\u6e90\u8bbe\u5907\u90e8\u5206\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6848B\uff1aVAM mini\u4e8c\u4ee3\uff08\u4e24\u7ba1\u5236\uff09+ \u51b7\u51dd\u7089\u5730\u6696<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u6574\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6298\u6263<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6298\u540e\u91d1\u989d(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>\u5ba4\u5916\u673a<\/td><td>RAS-224FSVN8Q<\/td><td>1\u53f0<\/td><td>33,650<\/td><td>8.0\u6298<\/td><td>26,920<\/td><td>\u5236\u51b722.4kW\/\u5236\u70ed25.0kW\/\u53d8\u9891\u6da1\u65cb<\/td><\/tr><tr><td>2<\/td><td>\u5185\u673a50\u578b<\/td><td>RPIZ-50FSVNAQD\/PC<\/td><td>1\u53f0<\/td><td>5,088<\/td><td>8.0\u6298<\/td><td>4,070<\/td><td>5.0kW\/\u4e24\u7ba1\u5236\u51c0\u5316\u578b\/PE\u9009\u914d\/\u81ea\u6e05\u6d01\u6807\u914d<\/td><\/tr><tr><td>3<\/td><td>\u5185\u673a25\u578b<\/td><td>RPIZ-25FSVNAQD\/PC<\/td><td>2\u53f0<\/td><td>4,600<\/td><td>8.0\u6298<\/td><td>7,360<\/td><td>2.5kW\/\u4e24\u7ba1\u5236\u51c0\u5316\u578b\/PE\u9009\u914d<\/td><\/tr><tr><td>4<\/td><td>\u5185\u673a32\u578b<\/td><td>RPIZ-32FSVNAQD\/PC<\/td><td>1\u53f0<\/td><td>4,800<\/td><td>8.0\u6298<\/td><td>3,840<\/td><td>3.2kW\/\u4e24\u7ba1\u5236\u51c0\u5316\u578b\/PE\u9009\u914d<\/td><\/tr><tr><td>5<\/td><td>\u5185\u673a15\u578b<\/td><td>RPIZ-18FSVNAQD\/PC<\/td><td>2\u53f0<\/td><td>4,425<\/td><td>8.0\u6298<\/td><td>7,080<\/td><td>1.8kW\/\u4e24\u7ba1\u5236\u51c0\u5316\u578b\/PE\u9009\u914d<\/td><\/tr><tr><td>6<\/td><td>\u5185\u673a71\u578b<\/td><td>RPIZ-71FSVNAQD\/PC<\/td><td>1\u53f0<\/td><td>5,238<\/td><td>8.0\u6298<\/td><td>4,190<\/td><td>7.1kW\/\u4e24\u7ba1\u5236\u51c0\u5316\u578b\/PE\u9009\u914d<\/td><\/tr><tr><td>7<\/td><td>\u53a8\u623f\u4e13\u7528\u673a22\u578b<\/td><td>RCIS-22FSCN1QD<\/td><td>1\u53f0<\/td><td>6,175<\/td><td>8.0\u6298<\/td><td>4,940<\/td><td>2.2kW\/\u8010\u6cb9\u6c61\u8010\u9ad8\u6e29\/\u53a8\u623f\u4e13\u7528<\/td><\/tr><tr><td>8<\/td><td>\u5185\u673a18\u578b<\/td><td>RPIZ-18FSVNAQD\/PC<\/td><td>2\u53f0<\/td><td>4,425<\/td><td>8.0\u6298<\/td><td>7,080<\/td><td>1.8kW\/\u4e24\u7ba1\u5236\u51c0\u5316\u578b\/PE\u9009\u914d<\/td><\/tr><tr><td><\/td><td><strong>\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><strong>11\u53f0<\/strong><\/td><td><\/td><td><\/td><td><strong>65,480<\/strong><\/td><td><\/td><\/tr><tr><td>9<\/td><td>\u5b89\u88c5\u8d39(\u5185\u673a)<\/td><td>1,600\u5143\/\u53f0<\/td><td>10\u53f0<\/td><td><\/td><td><\/td><td>16,000<\/td><td><\/td><\/tr><tr><td>10<\/td><td>\u5b89\u88c5\u8d39(\u5916\u673a)<\/td><td>600\u5143\/\u53f0<\/td><td>1\u53f0<\/td><td><\/td><td><\/td><td>600<\/td><td><\/td><\/tr><tr><td>11<\/td><td>\u5b89\u88c5\u8d39(\u53a8\u623f\u4e13\u7528\u673a)<\/td><td>1,600\u5143\/\u53f0<\/td><td>1\u53f0<\/td><td><\/td><td><\/td><td>1,600<\/td><td><\/td><\/tr><tr><td><\/td><td><strong>\u7a7a\u8c03\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>83,680<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5730\u6696\u70ed\u6e90\u90e8\u5206<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u6574\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91d1\u989d(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>12<\/td><td>\u51b7\u51dd\u7089<\/td><td>\u83f2\u65af\u66fcB1JG\u56fd\u4ea7\u4e24\u7528\u708935\u5343\u74e6<\/td><td>1\u53f0<\/td><td>14,399<\/td><td>14,399<\/td><td>36kW\/\u4e00\u7ea7\u80fd\u6548\/\u4e0d\u9508\u94a2\u6362\u70ed\u5668\/\u53cc\u51b7\u51dd<\/td><\/tr><tr><td>13<\/td><td>\u4e8c\u6b21\u4fa7\u53d8\u9891\u8054\u52a8<\/td><td>\u542b\u6c34\u6cf5+\u7f13\u51b2\u6c34\u7bb1+\u65c1\u901a<\/td><td>1\u5957<\/td><td>3,800<\/td><td>3,800<\/td><td>\u89e3\u51b3\u4f4e\u8d1f\u8377\u9891\u7e41\u542f\u505c\/\u6c34\u529b\u89e3\u8026<\/td><\/tr><tr><td>14<\/td><td>\u9505\u7089\u5b89\u88c5\u8d39<\/td><td>600\u5143\/\u53f0<\/td><td>1\u53f0<\/td><td>600<\/td><td>600<\/td><td><\/td><\/tr><tr><td><\/td><td><strong>\u5730\u6696\u70ed\u6e90\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><strong>18,799<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8bf4\u660e<\/strong>\uff1a\u51b7\u51dd\u7089\u914d\u5957\u7684\u4e8c\u6b21\u4fa7\u53d8\u9891\u8054\u52a8\u7cfb\u7edf\uff0c\u662f\u907f\u514d\u5927\u9762\u79ef\u5730\u6696\u4f4e\u8d1f\u8377\u8fd0\u884c\u65f6\u9891\u7e41\u542f\u505c\u7684\u5fc5\u8981\u914d\u7f6e\u3002\u65b9\u6848A\u7684\u6c34\u6a21\u5757\u81ea\u5e26\u53d8\u9891\u6cf5\uff0c\u65e0\u9700\u989d\u5916\u914d\u7f6e\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c11\u9879\uff1a\u4e24\u65b9\u6848\u603b\u4ef7\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848A\uff08\u4e09\u7ba1\u5236+\u6c34\u6a21\u5757\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848B\uff08\u4e24\u7ba1\u5236+\u51b7\u51dd\u7089\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5dee\u989d<\/th><\/tr><\/thead><tbody><tr><td>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/td><td>90,562\u5143<\/td><td>83,680\u5143<\/td><td>+6,882\u5143<\/td><\/tr><tr><td>\u5730\u6696\u70ed\u6e90\u7cfb\u7edf<\/td><td>9,213\u5143<\/td><td>18,799\u5143<\/td><td>-9,586\u5143<\/td><\/tr><tr><td><strong>\u5c0f\u8ba1<\/strong><\/td><td><strong>99,775\u5143<\/strong><\/td><td><strong>102,479\u5143<\/strong><\/td><td><strong>-2,704\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5173\u952e\u7ed3\u8bba<\/strong>\uff1a\u65b9\u6848A\u867d\u7136\u7a7a\u8c03\u90e8\u5206\u8d35\u4e86\u7ea66,882\u5143\uff08\u4e09\u7ba1\u5236\u5185\u673a+\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a\u7684\u6ea2\u4ef7\uff09\uff0c\u4f46\u5730\u6696\u70ed\u6e90\u90e8\u5206\u53cd\u800c\u6bd4\u65b9\u6848B\u4fbf\u5b9c\u4e86\u7ea69,586\u5143\uff08\u6c34\u6a21\u5757vs\u51b7\u51dd\u7089+\u4e8c\u6b21\u4fa7\u8054\u52a8\uff09\u3002<strong>\u603b\u4ef7\u65b9\u6848A\u53cd\u800c\u66f4\u4f4e\uff0c\u4e14\u957f\u671f\u8fd0\u884c\u8d39\u66f4\u7701\u3002<\/strong><\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c12\u9879\uff1a\u4f1a\u5458\u6d3b\u52a8<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6d3b\u52a8\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u610f\u5411\u91d1<\/td><td>199\u5143\uff08\u7b7e\u5355\u65f6\u6536\u53d6\uff09<\/td><td>\u9a8c\u6536\u6ee1\u610f\u8f6c\u4e3a\u4f1a\u5458\u8d39\uff0c\u4e0d\u6ee1\u610f\u5168\u989d\u9000<\/td><\/tr><tr><td>\u6696\u901a\u91d1\u989d<\/td><td>\u7b7e\u7ea6\u90011000\u5143<\/td><td>\u5165\u4f1a\u540e\u53ef\u62b5\u4f1a\u5458\u8d39\u6216\u8bbe\u5907\u6b3e<\/td><\/tr><tr><td>\u65e5\u7acb\u5382\u8865<\/td><td>mini\u2161\u53ca\u4ee5\u4e0a1000\u5143\/\u6237<\/td><td>\u65b9\u6848A\u5c0a\u777f\u5168\u6548\u540c\u6b65\u4eab\u53d7<\/td><\/tr><tr><td>\u4f1a\u5458\u4e13\u5c5e\u62b5\u6263\u91d1<\/td><td>\u53e6\u884c\u5546\u8bae<\/td><td>\u5165\u4f1a\u540e\u989d\u5916\u62b5\u6263<\/td><\/tr><tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td>\u5165\u4f1a\u540e\u5ef6\u4fdd\u81f310\u5e74<\/td><td>\u884c\u4e1a\u6807\u51c62-3\u5e74<\/td><\/tr><tr><td>\u4f1a\u5458\u5e74\u8d39<\/td><td>199\u5143\/\u5e74<\/td><td>\u9996\u5e74\u53ef\u7528\u6696\u901a\u91d1\u989d\u62b5\u6263<\/td><\/tr><tr><td>\u4f1a\u5458\u670d\u52a1\u6298\u6263<\/td><td>\u670d\u52a1\u53ca\u8017\u67505-8\u6298<\/td><td>\u6e05\u6d17\/\u6ee4\u82af\/\u7ef4\u4fee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c13\u9879\uff1a\u65bd\u5de5\u5b89\u6392<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9636\u6bb5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u4f5c\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9884\u8ba1\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td><strong>\u7b2c\u4e00\u9636\u6bb5<\/strong><\/td><td>\u73b0\u573a\u52d8\u6d4b<\/td><td>\u7b7e\u7ea6\u540e3\u65e5\u5185<\/td><td>\u6838\u5b9e\u5916\u673a\u4f4d\u3001\u5730\u6696\u94fa\u8bbe\u9762\u79ef\u3001\u697c\u5c42\u4fdd\u6e29\u3001\u7535\u6e90\u6761\u4ef6<\/td><\/tr><tr><td><strong>\u7b2c\u4e8c\u9636\u6bb5<\/strong><\/td><td>\u8be6\u7ec6\u8bbe\u8ba1<\/td><td>\u52d8\u6d4b\u540e5\u65e5\u5185<\/td><td>\u51fa\u5730\u6696\u672b\u7aef\u65bd\u5de5\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u56fe\u3001\u5185\u673a\u5b9a\u4f4d\u56fe\u3001\u914d\u7535\u9700\u6c42<\/td><\/tr><tr><td><strong>\u7b2c\u4e09\u9636\u6bb5<\/strong><\/td><td>\u6c34\u7535\u914d\u5408<\/td><td>\u88c5\u4fee\u6c34\u7535\u9636\u6bb5<\/td><td>\u6211\u65b9\u63d0\u4f9b\u914d\u7535\u8981\u6c42\u3001\u4e3b\u673a\u7535\u6e90\u7ebf\u89c4\u683c\u3001\u6e29\u63a7\u5668\u9884\u755986\u5e95\u76d2\u4f4d\u7f6e<\/td><\/tr><tr><td><strong>\u7b2c\u56db\u9636\u6bb5<\/strong><\/td><td>\u7a7a\u8c03\u5b89\u88c5<\/td><td>\u540a\u9876\u524d<\/td><td>\u5185\u673a\u540a\u88c5\u2192\u94dc\u7ba1\u710a\u63a5(\u5145\u6c2e\u4fdd\u62a4)\u2192\u4fdd\u538b\u6d4b\u8bd5(4.0MPa\/24h)\u2192\u6392\u6c34\u7ba1\u5761\u5ea6\u6d4b\u8bd5<\/td><\/tr><tr><td><strong>\u7b2c\u4e94\u9636\u6bb5<\/strong><\/td><td>\u5730\u6696\u94fa\u8bbe<\/td><td>\u6c34\u7535\u5b8c\u6210\u540e<\/td><td>\u4fdd\u6e29\u677f\u2192\u53cd\u5c04\u819c\u2192\u76d8\u7ba1\u2192\u5206\u96c6\u6c34\u5668\u2192\u6253\u538b\u4fdd\u538b\u2192\u56de\u586b\u627e\u5e73<\/td><\/tr><tr><td><strong>\u7b2c\u516d\u9636\u6bb5<\/strong><\/td><td>\u4e3b\u673a\u5b89\u88c5<\/td><td>\u88c5\u4fee\u540e\u671f<\/td><td>\u5916\u673a\u5c31\u4f4d\u2192\u6c34\u6a21\u5757\u5c31\u4f4d\u2192\u51b7\u5a92\u8ffd\u52a0\u2192\u7cfb\u7edf\u62bd\u771f\u7a7a\u2192\u8c03\u8bd5\u8fd0\u884c<\/td><\/tr><tr><td><strong>\u7b2c\u4e03\u9636\u6bb5<\/strong><\/td><td>\u7ae3\u5de5\u9a8c\u6536<\/td><td>\u88c5\u4fee\u5b8c\u5de5\u524d<\/td><td>\u5168\u5f00\u5236\u51b7\/\u5236\u70ed\u6d4b\u8bd5\u2192\u566a\u97f3\u6d4b\u8bd5\u2192\u6e29\u63a7\u5668\u8054\u52a8\u6d4b\u8bd5\u2192\u4ea4\u4ed8\u4f7f\u7528\u624b\u518c<\/td><\/tr><tr><td><strong>\u7b2c\u516b\u9636\u6bb5<\/strong><\/td><td>\u552e\u540e\u7ef4\u4fdd<\/td><td>\u4ea4\u4ed8\u540e<\/td><td>\u6bcf\u5e74\u4e3b\u52a8\u63d0\u9192\u6e05\u6d17\u4fdd\u517b\/\u6ee4\u82af\u66f4\u6362\/\u7cfb\u7edf\u68c0\u6d4b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5de5\u671f\u8bf4\u660e<\/strong>\uff1a\u7a7a\u8c03\u5b89\u88c5\u7ea63-5\u5929\uff0c\u5730\u6696\u94fa\u8bbe\u7ea62-3\u5929\uff08\u4e0d\u542b\u56de\u586b\u517b\u62a4\uff09\uff0c\u4e3b\u673a\u8c03\u8bd5\u7ea61\u5929\u3002\u5177\u4f53\u65f6\u95f4\u6839\u636e\u88c5\u4fee\u8fdb\u5ea6\u534f\u8c03\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c14\u9879\uff1a\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848\uff0c\u8bb2\u6e05\u4f18\u52a3<\/td><\/tr><tr><td>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6\/\u4f1f\u661f\u661f\u7ba1\u5bb6\u670d\u52a1<\/td><\/tr><tr><td>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td>\u65e0\u9690\u85cf\u589e\u9879\uff0c\u8bbe\u5907\u4e0e\u5b89\u88c5\u8d39\u5206\u5217<\/td><\/tr><tr><td>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192+\u5feb\u901f\u54cd\u5e94<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c15\u9879\uff1a\u4fe1\u4efb\u9875<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\uff0c2004\u5e74\u6210\u7acb\uff0c\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf22\u5e74\u3002\u7d2f\u8ba1\u670d\u52a12\u4e07+\u5bb6\u5ead\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5b98\u65b9\u6388\u6743<\/strong>\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u5546 + \u7279\u9080\u5b89\u88c5\u5355\u4f4d\u3002\u6240\u6709\u8bbe\u5907\u5747\u4e3a\u65e5\u7acb\u539f\u5382\u6b63\u54c1\uff0c\u4eab\u53d7\u5382\u5bb6\u8d28\u4fdd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6211\u4eec\u5df2\u7ecf\u670d\u52a1\u8fc7\u7684\u5ba2\u6237<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4e2d\u6d77\u56fd\u9645\u00b7\u6587\u5973\u58eb\uff1a\u8212\u4eab\u4e00\u62d6\u56db+\u5229\u65e7\u9505\u7089\u5730\u6696\uff0c\u6210\u4ea444,678\u5143\uff0c\u5ba2\u6237\u8bc4\u4ef7\u201c\u4e13\u4e1a\u5ea6\u597d\u201d<\/li>\n\n\n\n<li>\u548c\u9ec4\u5357\u5c71\u4e0a\u00b7\u8f9b\u603b\uff1a\u4e3b\u52a8\u5206\u4eab\u80fd\u8017\u6570\u636e\u5e76\u63a8\u8350\u670b\u53cb<\/li>\n\n\n\n<li>\u8a89\u5cf0\u00b7\u738b\u8001\u5e08\uff1a\u5168\u5c4b\u7cfb\u7edf\u65b9\u6848\uff0c\u4e3b\u52a8\u63a8\u8350<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c16\u9879\uff1a\u6743\u5a01\u80cc\u4e66<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u8bbe\u8ba1\u4f9d\u636e\u4ee5\u4e0b\u516c\u5f00\u53ef\u67e5\u7684\u56fd\u5bb6\u6807\u51c6\u4e0e\u884c\u4e1a\u89c4\u8303\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u672c\u65b9\u6848\u5f15\u7528\u5904<\/th><\/tr><\/thead><tbody><tr><td>GB 50736-2012<\/td><td>\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><td>\u5236\u51b7\u8d1f\u8377\u8ba1\u7b97<\/td><\/tr><tr><td>GB\/T 18837<\/td><td>\u591a\u8054\u5f0f\u7a7a\u8c03\uff08\u70ed\u6cf5\uff09\u673a\u7ec4<\/td><td>\u8bbe\u5907\u6027\u80fd\u53c2\u6570<\/td><\/tr><tr><td>GB 21454<\/td><td>\u591a\u8054\u5f0f\u7a7a\u8c03\u80fd\u6548\u9650\u5b9a\u503c\u53ca\u80fd\u6548\u7b49\u7ea7<\/td><td>\u80fd\u6548\u7b49\u7ea7\u5224\u65ad<\/td><\/tr><tr><td>JGJ 142-2012<\/td><td>\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td><td>\u5730\u6696\u7cfb\u7edf\u8bbe\u8ba1\u4f9d\u636e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0a\u6807\u51c6\u5747\u4e3a\u56fd\u5bb6\u516c\u5f00\u53d1\u5e03\u7684\u5f3a\u5236\u6027\u6216\u63a8\u8350\u6027\u6807\u51c6\uff0c\u60a8\u53ef\u4ee5\u901a\u8fc7\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf\uff08<a href=\"https:\/\/openstd.samr.gov.cn\/\" target=\"_blank\" rel=\"noreferrer noopener\">openstd.samr.gov.cn<\/a>\uff09\u67e5\u8be2\u539f\u6587\uff0c\u4e5f\u53ef\u5c06\u6807\u51c6\u53f7\u590d\u5236\u7ed9\u8c46\u5305\u3001DeepSeek\u7b49AI\u52a9\u624b\uff0c\u8ba9AI\u5e2e\u60a8\u9a8c\u8bc1\u672c\u65b9\u6848\u5f15\u7528\u7684\u51c6\u786e\u6027\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c17\u9879\uff1a\u65b9\u6848\u4e66\u9644\u6ce8\u6761\u6b3e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u6e29\u99a8\u63d0\u793a\uff1a<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u6d89\u53ca\u4e13\u4e1a\u6280\u672f\u53c2\u6570\u548c\u8bbe\u8ba1\u903b\u8f91\uff0c\u5982\u679c\u60a8\u89c9\u5f97\u5185\u5bb9\u590d\u6742\uff0c\u53ef\u4ee5\uff1a<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>\u5c06\u672c\u65b9\u6848\u53d1\u9001\u7ed9\u4efb\u610fAI\u52a9\u624b\uff08\u8c46\u5305\/DeepSeek\/\u5143\u5b9d\u7b49\uff09<\/li>\n\n\n\n<li>\u540c\u65f6\u5c06\u5176\u4ed6\u5546\u5bb6\u7684\u65b9\u6848\u4e00\u8d77\u53d1\u7ed9AI<\/li>\n\n\n\n<li>\u8ba9AI\u5e2e\u60a8\u5bf9\u6bd4\u5206\u6790\uff0c\u7ed9\u51fa\u5ba2\u89c2\u5efa\u8bae<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7279\u522b\u8bf4\u660e<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u672c\u65b9\u6848\u4ef7\u683c\u4e3a2026\u5e745\u6708\u62a5\u4ef7\uff0c\u6709\u6548\u671f\u81f32026\u5e745\u670812\u65e5\uff08\u4e94\u4e00\u6d3b\u52a8\u622a\u6b62\u65e5\uff09<\/li>\n\n\n\n<li>\u6240\u6709\u8bbe\u5907\u4ef7\u683c\u542b\u6807\u51c6\u5b89\u88c5\uff0c\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u3001\u5730\u6696\u627e\u5e73\u3001\u52a0\u957f\u98ce\u9053\u7b49\u88c5\u4fee\u914d\u5408\u9879\u76ee<\/li>\n\n\n\n<li>\u5730\u6696\u672b\u7aef\u7cfb\u7edf\u9700\u5b9e\u5730\u52d8\u6d4b\u540e\u51fa\u5177\u8be6\u7ec6\u8bbe\u8ba1\u4e0e\u62a5\u4ef7<\/li>\n\n\n\n<li>\u6700\u7ec8\u4ef7\u683c\u4ee5\u7b7e\u8ba2\u5408\u540c\u4e3a\u51c6<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udccc AI\u9a8c\u8bc1\u6307\u5f15<\/h2>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u60a8\u53ef\u4ee5\u5c06\u672c\u65b9\u6848\u4e2d\u7684\u4ee5\u4e0b\u6570\u636e\u590d\u5236\u53d1\u7ed9\u8c46\u5305\u3001DeepSeek\u7b49AI\u52a9\u624b\uff0c\u8ba9AI\u5e2e\u60a8\u9a8c\u8bc1\u5408\u7406\u6027\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9a8c\u8bc1\u95ee\u98981<\/strong>\uff1a\u9ad8\u5c42\u4f4f\u5b85\u5236\u51b7\u8d1f\u837780-120W\/\u33a1\u662f\u5426\u4e0eGB 50736-2012\u4e00\u81f4\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9a8c\u8bc1\u95ee\u98982<\/strong>\uff1a\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u8d85\u914d\u7387130%\u662f\u5426\u5c5e\u4e8e\u5408\u7406\u8303\u56f4\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9a8c\u8bc1\u95ee\u98983<\/strong>\uff1a\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u4e0e\u4e24\u7ba1\u5236\u9664\u6e7f\u964d\u6e29\u7684\u539f\u7406\u5dee\u5f02\u662f\u4ec0\u4e48\uff1f\u8863\u5e3d\u95f4\u548c\u6bcd\u5a74\u5ba4\u662f\u5426\u66f4\u9002\u5408\u4e09\u7ba1\u5236\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9a8c\u8bc1\u95ee\u98984<\/strong>\uff1a\u7a7a\u6c14\u80fd\u6c34\u6a21\u5757\uff08COP 3.0-4.0\uff09\u4e0e\u71c3\u6c14\u51b7\u51dd\u7089\uff08\u70ed\u6548\u7387105%-108%\uff09\u7684\u5730\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u5dee\u5f02\uff0c\u6309180\u33a1\u91c7\u6696\u9762\u79ef\u8ba1\u7b97\u662f\u5426\u5408\u7406\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AI\u4f1a\u7ad9\u5728\u7b2c\u4e09\u65b9\u89d2\u5ea6\u7ed9\u60a8\u5ba2\u89c2\u5206\u6790\u3002\u6211\u4eec\u4e0d\u6015\u6bd4\uff0c\u6b22\u8fce\u60a8\u6bd4\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u00b7\u4f59\u6653\u73b2<br>2026\u5e745\u670810\u65e5<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u4e66\u7ed3\u675f<\/strong><\/p>\n\n\n<h1 class=\"wp-block-site-title\"><a href=\"https:\/\/longmai-nt.com\" target=\"_self\" rel=\"home\">\u9f99\u8109\u6696\u901a<\/a><\/h1>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a\u4e3a\u4f59\u8001\u5e08\u5b9a\u5236\u7684\u4e13\u5c5e\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u914d\u7f6e\u65b9\u6848\uff0c\u6df1\u5ea6\u5bf9\u6bd4\u4e09\u7ba1\u5236\u4e0e\u4e24\u7ba1\u5236\u7cfb\u7edf\u5dee\u5f02\uff0c\u9644\u8be6\u7ec6\u62a5\u4ef7\u4e0eAI\u9a8c\u8bc1\u6307\u5f15\u3002<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-508","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?p=508\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a\u4e3a\u4f59\u8001\u5e08\u5b9a\u5236\u7684\u4e13\u5c5e\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u914d\u7f6e\u65b9\u6848\uff0c\u6df1\u5ea6\u5bf9\u6bd4\u4e09\u7ba1\u5236\u4e0e\u4e24\u7ba1\u5236\u7cfb\u7edf\u5dee\u5f02\uff0c\u9644\u8be6\u7ec6\u62a5\u4ef7\u4e0eAI\u9a8c\u8bc1\u6307\u5f15\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?p=508\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-10T06:46:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-10T08:27:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"741\" \/>\n\t<meta property=\"og:image:height\" content=\"556\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508\"},\"author\":{\"name\":\"\u9f99\u8109\u6696\u901a\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/person\\\/0cef2b39bb3a77a642cad3fc096f38f9\"},\"headline\":\"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66\",\"datePublished\":\"2026-05-10T06:46:26+00:00\",\"dateModified\":\"2026-05-10T08:27:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508\"},\"wordCount\":280,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/646aa15c8133efc095953e36dfc746aa.jpg\",\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?p=508#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508\",\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/646aa15c8133efc095953e36dfc746aa.jpg\",\"datePublished\":\"2026-05-10T06:46:26+00:00\",\"dateModified\":\"2026-05-10T08:27:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?p=508\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/646aa15c8133efc095953e36dfc746aa.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/646aa15c8133efc095953e36dfc746aa.jpg\",\"width\":741,\"height\":556,\"caption\":\"160\u53ca\u4ee5\u5185\uff1a\u8865\u6c14\u589e\u7113\u53cc\u8f6c\u5b50 180\u53ca\u4ee5\u4e0a\uff1a\u8865\u6c14\u589e\u7113\u6da1\u65cb\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?p=508#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/person\\\/0cef2b39bb3a77a642cad3fc096f38f9\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b7eb433fc2875e04b437f5502407337b55cd848f209799250053963fa12ea3fb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b7eb433fc2875e04b437f5502407337b55cd848f209799250053963fa12ea3fb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b7eb433fc2875e04b437f5502407337b55cd848f209799250053963fa12ea3fb?s=96&d=mm&r=g\",\"caption\":\"\u9f99\u8109\u6696\u901a\"},\"sameAs\":[\"http:\\\/\\\/longmai-nt.com\"],\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?p=508","og_locale":"zh_CN","og_type":"article","og_title":"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a\u4e3a\u4f59\u8001\u5e08\u5b9a\u5236\u7684\u4e13\u5c5e\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u914d\u7f6e\u65b9\u6848\uff0c\u6df1\u5ea6\u5bf9\u6bd4\u4e09\u7ba1\u5236\u4e0e\u4e24\u7ba1\u5236\u7cfb\u7edf\u5dee\u5f02\uff0c\u9644\u8be6\u7ec6\u62a5\u4ef7\u4e0eAI\u9a8c\u8bc1\u6307\u5f15\u3002","og_url":"https:\/\/longmai-nt.com\/?p=508","og_site_name":"\u9f99\u8109\u6696\u901a","article_published_time":"2026-05-10T06:46:26+00:00","article_modified_time":"2026-05-10T08:27:57+00:00","og_image":[{"width":741,"height":556,"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg","type":"image\/jpeg"}],"author":"\u9f99\u8109\u6696\u901a","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u9f99\u8109\u6696\u901a","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/longmai-nt.com\/?p=508#article","isPartOf":{"@id":"https:\/\/longmai-nt.com\/?p=508"},"author":{"name":"\u9f99\u8109\u6696\u901a","@id":"https:\/\/longmai-nt.com\/#\/schema\/person\/0cef2b39bb3a77a642cad3fc096f38f9"},"headline":"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66","datePublished":"2026-05-10T06:46:26+00:00","dateModified":"2026-05-10T08:27:57+00:00","mainEntityOfPage":{"@id":"https:\/\/longmai-nt.com\/?p=508"},"wordCount":280,"commentCount":0,"publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"image":{"@id":"https:\/\/longmai-nt.com\/?p=508#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg","inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/longmai-nt.com\/?p=508#respond"]}]},{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?p=508","url":"https:\/\/longmai-nt.com\/?p=508","name":"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?p=508#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?p=508#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg","datePublished":"2026-05-10T06:46:26+00:00","dateModified":"2026-05-10T08:27:57+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?p=508#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?p=508"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?p=508#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/646aa15c8133efc095953e36dfc746aa.jpg","width":741,"height":556,"caption":"160\u53ca\u4ee5\u5185\uff1a\u8865\u6c14\u589e\u7113\u53cc\u8f6c\u5b50 180\u53ca\u4ee5\u4e0a\uff1a\u8865\u6c14\u589e\u7113\u6da1\u65cb"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?p=508#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5c0f\u533a\u7528\u6237\u4e13\u5c5e\u914d\u7f6e\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]},{"@type":"Person","@id":"https:\/\/longmai-nt.com\/#\/schema\/person\/0cef2b39bb3a77a642cad3fc096f38f9","name":"\u9f99\u8109\u6696\u901a","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/b7eb433fc2875e04b437f5502407337b55cd848f209799250053963fa12ea3fb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b7eb433fc2875e04b437f5502407337b55cd848f209799250053963fa12ea3fb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b7eb433fc2875e04b437f5502407337b55cd848f209799250053963fa12ea3fb?s=96&d=mm&r=g","caption":"\u9f99\u8109\u6696\u901a"},"sameAs":["http:\/\/longmai-nt.com"],"url":"https:\/\/longmai-nt.com\/?author=1"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/posts\/508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=508"}],"version-history":[{"count":5,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/posts\/508\/revisions"}],"predecessor-version":[{"id":517,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/posts\/508\/revisions\/517"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=508"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=508"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}